-- (C) COPYRIGHT HEWLETT-PACKARD COMPANY 2015. -- -- LaserJet 452 Printer Model Specific MIB. -- -- Generated on Sep. 16, 2015. -- -- Company names and product names mentioned herein may be -- trademarks, and/or registered trademarks of their respective -- companies. -- -- For internal and external use. -- -- This MIB describes all the printer model specific -- objects supported by the LaserJet 452 printer -- when networked connected. -- -- The following MIBs also contain objects supported -- by a LaserJet 452 printer: -- -- IEEE 802.11 MIB -- IEEE 802.1X MIB -- rfc 2790 Host Resources MIB -- rfc 3411 SNMP Framework MIB -- rfc 3412 SNMP MPD MIB -- rfc 3418 SNMP MIB -- rfc 3805 Printer MIB -- rfc 4022 TCP MIB -- rfc 4293 IP MIB -- rfc 4113 UDP MIB -- PWG 5107.1-2005 Printer Port Monitor MIB -- -- This MIB complies with the following RFCs: -- -- rfc 1157 Simple Network Management Protocol -- rfc 2578 Structure of Management Information Version 2 -- -- Notes: -- -- 1) Objects containing a string which are defined in this MIB use the -- first two bytes to hold the symbol set used to encode the string. -- The Roman-8 symbol set has a hex encoding of 0x0115. Other -- symbol sets are listed in the PCL 5 Comparison Guide in table -- C-1 Symbol Set Values. -- -- 2) Some of the objects included are only supported if an accessory -- is installed. These accessories include: -- MIO based accessories -- SIMM based accessories -- Paper handling accessories LJ452-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 DisplayString FROM SNMPv2-TC; hpPrintServer OBJECT IDENTIFIER ::= { iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 11} dm OBJECT IDENTIFIER ::= { hpPrintServer nm(2) hpsystem(3) net-peripheral(9) netdm(4) 2} device OBJECT IDENTIFIER ::= { dm 1 } system OBJECT IDENTIFIER ::= { device 1 } settings-system OBJECT IDENTIFIER ::= { system 1 } destination-subsystem OBJECT IDENTIFIER ::= { device 4 } print-engine OBJECT IDENTIFIER ::= { destination-subsystem 1 } settings-prt-eng OBJECT IDENTIFIER ::= { print-engine 1 } marking-agent-density OBJECT IDENTIFIER ::= { settings-prt-eng 9 } status-prt-eng OBJECT IDENTIFIER ::= { print-engine 2 } marking-agent OBJECT IDENTIFIER ::= { print-engine 5 } settings-marking-agent OBJECT IDENTIFIER ::= { marking-agent 1 } hrm OBJECT IDENTIFIER ::= { dm 3 } hrStorage OBJECT IDENTIFIER ::= { hrm 2 } hrStorageTable OBJECT IDENTIFIER ::= { hrStorage 3 } hrStorageEntry OBJECT IDENTIFIER ::= { hrStorageTable 1 } hrDevice OBJECT IDENTIFIER ::= { hrm 3 } hrDeviceTable OBJECT IDENTIFIER ::= { hrDevice 2 } hrDeviceEntry OBJECT IDENTIFIER ::= { hrDeviceTable 1 } hrPrinterTable OBJECT IDENTIFIER ::= { hrDevice 5 } hrPrinterEntry OBJECT IDENTIFIER ::= { hrPrinterTable 1 } iso OBJECT IDENTIFIER ::= { dm 1 } org OBJECT IDENTIFIER ::= { iso 3 } dod OBJECT IDENTIFIER ::= { org 6 } internet OBJECT IDENTIFIER ::= { dod 1 } private OBJECT IDENTIFIER ::= { internet 4 } enterprises OBJECT IDENTIFIER ::= { private 1 } nm OBJECT IDENTIFIER ::= { hpPrintServer 2 } interface OBJECT IDENTIFIER ::= { nm 4 } npCard OBJECT IDENTIFIER ::= { interface 3 } npCRCTable OBJECT IDENTIFIER ::= { npCard 15 } npCRCEntry OBJECT IDENTIFIER ::= { npCRCTable 1 } inetTrap OBJECT IDENTIFIER ::= { npCard 22 } inetTrapDestination OBJECT IDENTIFIER ::= { inetTrap 1 } inetTrapDestinationTable OBJECT IDENTIFIER ::= { inetTrapDestination 2 } inetTrapDestinationEntry OBJECT IDENTIFIER ::= { inetTrapDestinationTable 1 } trap OBJECT IDENTIFIER ::= { nm 13 } trapDest OBJECT IDENTIFIER ::= { trap 1 } trapFQDNTable OBJECT IDENTIFIER ::= { trapDest 7 } trapFQDNEntry OBJECT IDENTIFIER ::= { trapFQDNTable 1 } snmpAccess OBJECT IDENTIFIER ::= { nm 15 } community OBJECT IDENTIFIER ::= { snmpAccess 1 } npSys OBJECT IDENTIFIER ::= { npCard 1 } npConns OBJECT IDENTIFIER ::= { npCard 4 } npCfg OBJECT IDENTIFIER ::= { npCard 5 } npCfgAccessListTable OBJECT IDENTIFIER ::= { npCfg 9 } npCfgAccessListEntry OBJECT IDENTIFIER ::= { npCfgAccessListTable 1 } npTcp OBJECT IDENTIFIER ::= { npCard 6 } npCtl OBJECT IDENTIFIER ::= { npCard 7 } npPort OBJECT IDENTIFIER ::= { npCard 13 } npDhcp OBJECT IDENTIFIER ::= { npCard 16 } npWeb OBJECT IDENTIFIER ::= { npCard 18 } npSecurity OBJECT IDENTIFIER ::= { npCard 20 } npSecurityDot11EncryptedWEPKeyTable OBJECT IDENTIFIER ::= { npSecurity 7 } npSecurityDot11EncryptedWEPKeyEntry OBJECT IDENTIFIER ::= { npSecurityDot11EncryptedWEPKeyTable 1 } npSecurityDot11SSIDTable OBJECT IDENTIFIER ::= { npSecurity 9 } npSecurityDot11SSIDEntry OBJECT IDENTIFIER ::= { npSecurityDot11SSIDTable 1 } system OBJECT IDENTIFIER ::= { nm 3 } netPeripheral OBJECT IDENTIFIER ::= { system 9 } netPrinter OBJECT IDENTIFIER ::= { netPeripheral 1 } generalDeviceStatus OBJECT IDENTIFIER ::= { netPrinter 1 } netPML OBJECT IDENTIFIER ::= { netPeripheral 4 } netPMLtrap OBJECT IDENTIFIER ::= { netPML 1 } npNpi OBJECT IDENTIFIER ::= { npCard 8 } npNpiPeripheralAttributeEntry OBJECT IDENTIFIER ::= { npNpi 3 } npNpiCardAttributeEntry OBJECT IDENTIFIER ::= { npNpi 4 } gdStatusEntry OBJECT IDENTIFIER ::= { generalDeviceStatus 2 } job OBJECT IDENTIFIER ::= { system 6 } photo-job OBJECT IDENTIFIER ::= { job 8 } device-configure OBJECT IDENTIFIER ::= { settings-system 32 } status-system OBJECT IDENTIFIER ::= { system 2 } display OBJECT IDENTIFIER ::= { status-system 20 } display-status OBJECT IDENTIFIER ::= { display 1 } id OBJECT IDENTIFIER ::= { system 3 } interface OBJECT IDENTIFIER ::= { system 4 } simm OBJECT IDENTIFIER ::= { interface 1 } simm1 OBJECT IDENTIFIER ::= { simm 1 } test OBJECT IDENTIFIER ::= { system 5 } settings-job OBJECT IDENTIFIER ::= { job 1 } active-print-jobs OBJECT IDENTIFIER ::= { job 2 } job-being-parsed OBJECT IDENTIFIER ::= { active-print-jobs 1 } job-info OBJECT IDENTIFIER ::= { job 5 } errorlog OBJECT IDENTIFIER ::= { system 11 } error1 OBJECT IDENTIFIER ::= { errorlog 1 } error2 OBJECT IDENTIFIER ::= { errorlog 2 } error3 OBJECT IDENTIFIER ::= { errorlog 3 } error4 OBJECT IDENTIFIER ::= { errorlog 4 } error5 OBJECT IDENTIFIER ::= { errorlog 5 } error6 OBJECT IDENTIFIER ::= { errorlog 6 } error7 OBJECT IDENTIFIER ::= { errorlog 7 } error8 OBJECT IDENTIFIER ::= { errorlog 8 } error9 OBJECT IDENTIFIER ::= { errorlog 9 } error10 OBJECT IDENTIFIER ::= { errorlog 10 } firmware-download OBJECT IDENTIFIER ::= { system 18 } source-subsystem OBJECT IDENTIFIER ::= { device 2 } io OBJECT IDENTIFIER ::= { source-subsystem 1 } settings-io OBJECT IDENTIFIER ::= { io 1 } processing-subsystem OBJECT IDENTIFIER ::= { device 3 } pdl OBJECT IDENTIFIER ::= { processing-subsystem 3 } settings-pdl OBJECT IDENTIFIER ::= { pdl 1 } pdl-pcl OBJECT IDENTIFIER ::= { pdl 3 } pdl-postscript OBJECT IDENTIFIER ::= { pdl 4 } pjl OBJECT IDENTIFIER ::= { processing-subsystem 5 } intray OBJECT IDENTIFIER ::= { print-engine 3 } settings-intray OBJECT IDENTIFIER ::= { intray 1 } intrays OBJECT IDENTIFIER ::= { intray 3 } intray1 OBJECT IDENTIFIER ::= { intrays 1 } intray2 OBJECT IDENTIFIER ::= { intrays 2 } intray3 OBJECT IDENTIFIER ::= { intrays 3 } imaging OBJECT IDENTIFIER ::= { print-engine 6 } print-media OBJECT IDENTIFIER ::= { print-engine 8 } settings-print-media OBJECT IDENTIFIER ::= { print-media 1 } media-info OBJECT IDENTIFIER ::= { print-media 3 } media1 OBJECT IDENTIFIER ::= { media-info 1 } media2 OBJECT IDENTIFIER ::= { media-info 2 } media3 OBJECT IDENTIFIER ::= { media-info 3 } media4 OBJECT IDENTIFIER ::= { media-info 4 } media5 OBJECT IDENTIFIER ::= { media-info 5 } media6 OBJECT IDENTIFIER ::= { media-info 6 } media7 OBJECT IDENTIFIER ::= { media-info 7 } media8 OBJECT IDENTIFIER ::= { media-info 8 } media9 OBJECT IDENTIFIER ::= { media-info 9 } media10 OBJECT IDENTIFIER ::= { media-info 10 } media11 OBJECT IDENTIFIER ::= { media-info 11 } media12 OBJECT IDENTIFIER ::= { media-info 12 } media13 OBJECT IDENTIFIER ::= { media-info 13 } media14 OBJECT IDENTIFIER ::= { media-info 14 } media15 OBJECT IDENTIFIER ::= { media-info 15 } media16 OBJECT IDENTIFIER ::= { media-info 16 } media17 OBJECT IDENTIFIER ::= { media-info 17 } media18 OBJECT IDENTIFIER ::= { media-info 18 } media19 OBJECT IDENTIFIER ::= { media-info 19 } media20 OBJECT IDENTIFIER ::= { media-info 20 } media21 OBJECT IDENTIFIER ::= { media-info 21 } media22 OBJECT IDENTIFIER ::= { media-info 22 } media23 OBJECT IDENTIFIER ::= { media-info 23 } media24 OBJECT IDENTIFIER ::= { media-info 24 } media-modes OBJECT IDENTIFIER ::= { print-media 4 } consumables OBJECT IDENTIFIER ::= { print-engine 10 } consumables-1 OBJECT IDENTIFIER ::= { consumables 1 } consumable-status OBJECT IDENTIFIER ::= { consumables-1 1 } consumables-status OBJECT IDENTIFIER ::= { consumables 5 } consumables-life OBJECT IDENTIFIER ::= { consumables-status 1 } consumables-test OBJECT IDENTIFIER ::= { consumables 6 } printmib OBJECT IDENTIFIER ::= { dm 2 } prtGeneral OBJECT IDENTIFIER ::= { printmib 5 } prtGeneralTable OBJECT IDENTIFIER ::= { prtGeneral 1 } prtGeneralEntry OBJECT IDENTIFIER ::= { prtGeneralTable 1 } prtCover OBJECT IDENTIFIER ::= { printmib 6 } prtCoverTable OBJECT IDENTIFIER ::= { prtCover 1 } prtCoverEntry OBJECT IDENTIFIER ::= { prtCoverTable 1 } prtLocalization OBJECT IDENTIFIER ::= { printmib 7 } prtLocalizationTable OBJECT IDENTIFIER ::= { prtLocalization 1 } prtLocalizationEntry OBJECT IDENTIFIER ::= { prtLocalizationTable 1 } prtStorageRefTable OBJECT IDENTIFIER ::= { prtGeneral 2 } prtStorageRefEntry OBJECT IDENTIFIER ::= { prtStorageRefTable 1 } prtDeviceRefTable OBJECT IDENTIFIER ::= { prtGeneral 3 } prtDeviceRefEntry OBJECT IDENTIFIER ::= { prtDeviceRefTable 1 } prtInput OBJECT IDENTIFIER ::= { printmib 8 } prtInputTable OBJECT IDENTIFIER ::= { prtInput 2 } prtInputEntry OBJECT IDENTIFIER ::= { prtInputTable 1 } prtOutput OBJECT IDENTIFIER ::= { printmib 9 } prtOutputTable OBJECT IDENTIFIER ::= { prtOutput 2 } prtOutputEntry OBJECT IDENTIFIER ::= { prtOutputTable 1 } prtMarker OBJECT IDENTIFIER ::= { printmib 10 } prtMarkerTable OBJECT IDENTIFIER ::= { prtMarker 2 } prtMarkerEntry OBJECT IDENTIFIER ::= { prtMarkerTable 1 } prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 } prtMarkerSuppliesTable OBJECT IDENTIFIER ::= { prtMarkerSupplies 1 } prtMarkerSuppliesEntry OBJECT IDENTIFIER ::= { prtMarkerSuppliesTable 1 } prtMarkerColorant OBJECT IDENTIFIER ::= { printmib 12 } prtMarkerColorantTable OBJECT IDENTIFIER ::= { prtMarkerColorant 1 } prtMarkerColorantEntry OBJECT IDENTIFIER ::= { prtMarkerColorantTable 1 } prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 } prtMediaPathTable OBJECT IDENTIFIER ::= { prtMediaPath 4 } prtMediaPathEntry OBJECT IDENTIFIER ::= { prtMediaPathTable 1 } prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 } prtInterpreterTable OBJECT IDENTIFIER ::= { prtInterpreter 1 } prtInterpreterEntry OBJECT IDENTIFIER ::= { prtInterpreterTable 1 } prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 } prtConsoleDisplayBufferTable OBJECT IDENTIFIER ::= { prtConsoleDisplayBuffer 5 } prtConsoleDisplayBufferEntry OBJECT IDENTIFIER ::= { prtConsoleDisplayBufferTable 1 } prtConsoleLights OBJECT IDENTIFIER ::= { printmib 17 } prtConsoleLightTable OBJECT IDENTIFIER ::= { prtConsoleLights 6 } prtConsoleLightEntry OBJECT IDENTIFIER ::= { prtConsoleLightTable 1 } mono-color-switching-mode OBJECT-TYPE SYNTAX INTEGER { eNeverSwitch(1), eAlwaysSwitch(2), eLookAheadSwitch(3) } ACCESS read-write STATUS optional DESCRIPTION "This object allows the user to view/change the color/mono switching mode for a device. Additional information: This object allows the user to view/change the color/mono switching mode for a device." ::= { settings-system 31 } calibration-power-on-initiation OBJECT-TYPE SYNTAX INTEGER { eOff(1), eOn(2), eDelayed(3) } ACCESS read-write STATUS optional DESCRIPTION "This object determines when a power on calibration occurs. If eOn, then the calibration occurs immediately following boot. If eOff, then it never occurs. If eDelayed, then refer to the CALIBRATION-POWER-ON-DELAY PML object for the delay interval." ::= { settings-prt-eng 20 } calibration-power-on-delay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "This is the delay interval for the power on calibration in minutes. This PML object is only used if the CALIBRATION-POWER-ON-INITIATION PML object is set to eDelayed. Additional information: This is the delay interval for the power on calibration in minutes. The range in minutes for the product is 1-60 minutes. " ::= { settings-prt-eng 21 } calibration-pages-printed-initiation OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The number of pages that will be printed prior to an automatically initiated print calibration. If set to 0, it turns this calibration off. Additional information: This is the number of pages that will be printed prior to an automatically initiated print calibration. If set to 0, it turns this calibration off. The range for the product will be 0-500. On Raptor the default value is 200. On Kiwi the default value is 150" ::= { settings-prt-eng 22 } calibration-timer-initiation OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "This is a timer in minutes that will be set in between calibrations. When the timer expires, a calibration will automatically be initiated. If set to 0, it turns this calibration off. Additional information: This is a timer in minutes that will be set in between calibrations. If set to 0, it turns this calibration off. The range for the product will be 0-10080. When you set to a value of 2 (min) or any other legal value other than 0, the device does not immediately begin calibrating when the timer expires. The calibration takes place after the timer expires, the next job has finished printing, and a 15 minute period of inactivity has passed." ::= { settings-prt-eng 23 } marking-agent-density-setting OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the marking agent density setting for each of the marking agents installed. The Marking Agent (aka Print) density is the instantaneous amount of marking agent applied to the media while printing. A value of zero has the lowest print density, yielding a lighter page. A value of 10 has the highest print density, yielding a darker page. The device POS will document what values are supported. Additional information: See the description for PRINT-DENSITY ." ::= { marking-agent-density 1 } marking-agent-highlights-density-setting OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the marking agent highlights density setting for each of the marking agents installed. The value of this object is in the range of -5..+5. The Marking Agent (aka Print) density is the instantaneous amount of marking agent applied to the media while printing. A value of -5 has the lowest print density, yeilding a lighter pageA value of +5 the highest print density, yielding a darker page." ::= { marking-agent-density 2 } marking-agent-midtones-density-setting OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the marking agent midtones density setting for each of the marking agents installed. The value of this object is in the range of -5..+5. See MARKING-AGENT-HIGHLIGHTS-DENSITY-SETTING for a more specific description." ::= { marking-agent-density 3 } marking-agent-shadows-density-setting OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the marking agent shadows density setting for each of the marking agents installed. The value of this object is in the range of -5..+5. See MARKING-AGENT-HIGHLIGHTS-DENSITY-SETTING for a more specific description." ::= { marking-agent-density 4 } total-mono-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Total number of black pages printed by the device. Additional information: Total number of mono pages printed by the device." ::= { status-prt-eng 6 } total-color-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Total number of color pages printed by the device. Additional information: Total number of color pages printed by the device." ::= { status-prt-eng 7 } marker-density-calibration OBJECT-TYPE SYNTAX INTEGER { eNotCallibrating(1), eCalibrateALL(2), eCalibrateColorPlaneRegistration(5) } ACCESS read-write STATUS optional DESCRIPTION "Returns the calibration status or triggers a calibration cycle. All calibration procedures are used if set to eCalibrateALL. If set to eCalibrateDMAX then a full density engine calibration is triggered. If set to eCalibrateDHALF, then a Halftone calibration is triggered. Additional information: Returns the calibration status or triggers a calibration cycle." ::= { settings-marking-agent 11 } hrMemorySize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The amount of physical main memory contained by the host. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: The unit of measure for this object is 1024 bytes. The default value assumes the base printer with no additional memory." ::= { hrStorage 2 } hrStorageIndex OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each logical storage area contained by the host. Refer to RFC 1514, Host Resources MIB, for more details." ::= { hrStorageEntry 1 } hrStorageType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The type of storage represented by this entry. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: The object is constant for the product." ::= { hrStorageEntry 2 } hrStorageDescr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A description of the type and instance of the storage described by this entry. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: This object is not localized. For the product, this object is constant." ::= { hrStorageEntry 3 } hrStorageAllocationUnits OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The size, in bytes, of the data objects allocated from this pool. If this entry is monitoring sectors, blocks, buffers, or packets, for example, this number will commonly be greater than one. Otherwise this number will typically be one. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: Unit is one byte. For the product, this object is constant." ::= { hrStorageEntry 4 } hrStorageSize OBJECT-TYPE SYNTAX INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The size of the storage represented by this entry, in units of hrStorageAllocationUnits. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: Total formatter RAM. (The value of this object is hrMemorySize times the unit of measure for hrMemorySize. For this procduct this is 65536*1024 bytes.)" ::= { hrStorageEntry 5 } hrStorageUsed OBJECT-TYPE SYNTAX INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The amount of the storage represented by this entry that is allocated, in units of hrStorageAllocationUnits. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: This object returns the amount of memory in use by the printer at the current time. This object should not be used when creating a print job for the device because the amount of memory in use will likely be different when the printer processes the print job." ::= { hrStorageEntry 6 } hrStorageAllocationFailures OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of requests for storage represented by this entry that could not be honored due to not enough storage. It should be noted that as this object has a SYNTAX of Counter, that it does not have a defined initial value. However, it is recommended that this object be initialized to zero. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: This object is set to zero at power on and when any reset is done via prtGeneralReset. This object is incremented whenever the printer is short on memory (codewise: when PersMemoryCycle is called with a parameter of 2)." ::= { hrStorageEntry 7 } hrDeviceIndex OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each device contained by the host. The value for each device must remain constant at least from one re-initialization of the agent to the next re-initialization. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: The entry in the Device Table which describes the printer." ::= { hrDeviceEntry 1 } hrDeviceType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "An indication of the type of device. If this value is `hrDeviceProcessor { hrDeviceTypes 3 }' then an entry exists in the hrProcessorTable which corresponds to this device. If this value is `hrDeviceNetwork { hrDeviceTypes 4 }', then an entry exists in the hrNetworkTable which corresponds to this device. If this value is `hrDevicePrinter { hrDeviceTypes 5 }', then an entry exists in the hrPrinterTable which corresponds to this device. If this value is `hrDeviceDiskStorage { hrDeviceTypes 6 }', then an entry exists in the hrDiskStorageTable which corresponds to this device. Refer to RFC 1514, Host Resources MIB, for more details." ::= { hrDeviceEntry 2 } hrDeviceDescr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "A textual description of this device, including the device's manufacturer and revision, and optionally, its serial number. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: The serial number is not returned with this object. This object is not localized." ::= { hrDeviceEntry 3 } hrDeviceID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The product ID for this device. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: The complete OID reported by this object is: .1.3.6.1.4.1.11.2.3.9.1.2.48.3" ::= { hrDeviceEntry 4 } hrDeviceStatus OBJECT-TYPE SYNTAX INTEGER { eHrunning(2), eHwarning(3), eHdown(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The current operational state of the device described by this row of the table. A value unknown(1) indicates that the current state of the device is unknown. running(2) indicates that the device is up and running and that no unusual error conditions are known. The warning(3) state indicates that agent has been informed of an unusual error condition by the operational software (e.g., a disk device driver) but that the device is still 'operational'. An example would be high number of soft errors on a disk. A value of testing(4), indicates that the device is not available for use because it is in the testing state. The state of down(5) is used only when the agent has been informed that the device is not available for any use. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: The printer's condition is mapped as follows: eHrunning -- Printer ready to print or is printing. It may be in power save mode. eHwarning -- A condition exists that needs attention, but it is not currently preventing printing. A non-critical alert is active. eHdown -- Printer is not printing because it is offline, or a critical alert is active. Human interaction is needed to bring the printer to a ready state." ::= { hrDeviceEntry 5 } hrDeviceErrors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of errors detected on this device. It should be noted that as this object has a SYNTAX of Counter, that it does not have a defined initial value. However, it is recommended that this object be initialized to zero. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: This is the number of critical alerts that have been entered into the alert table since the device was powered on. The maximum value for this object is 2^32-1. At power-on, this object will be set to zero." ::= { hrDeviceEntry 6 } hrPrinterStatus OBJECT-TYPE SYNTAX INTEGER { eHother(1), eHidle(3), eHprinting(4), eHwarmup(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this printer device. When in the idle(1), printing(2), or warmup(3) state, the corresponding hrDeviceStatus should be running(2) or warning(3). When in the unknown state, the corresponding hrDeviceStatus should be unknown(1). Refer to RFC 1514, Host Resources MIB, for more details. Additional information: The printer's condition is mapped as follows: eHother -- The printer is offline, or a critical alert is active. eHidle -- The printer is not performing any of the items listed under eHprinting status. eHprinting -- A job is currently being processed or printed, or a PJL job is being processed. eHwarmup -- If hrDeviceStatus is eHdown, the printer is currently offline but is resolving the condition that caused it to be offline. It will be online when it is ready to print. If hrDeviceStatus is eHrunning, the printer was in power save mode and is now becoming ready to print. (In the product, this status only occurs very briefly at boot time. At no other time does the printer report 'eHwarmup' status.)" ::= { hrPrinterEntry 1 } hrPrinterDetectedErrorState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This object represents any error conditions detected by the printer. The error conditions are encoded as bits in an octet string, with the following definitions: Condition Bit # hrDeviceStatus lowPaper 0 warning(3) noPaper 1 down(5) lowToner 2 warning(3) noToner 3 down(5) doorOpen 4 down(5) jammed 5 down(5) offline 6 down(5) serviceRequested 7 warning(3) If multiple conditions are currently detected and the hrDeviceStatus would not otherwise be unknown(1) or testing(4), the hrDeviceStatus shall correspond to the worst state of those indicated, where down(5) is worse than warning(3) which is worse than running(2). Bits are numbered starting with the most significant bit of the first byte being bit 0, the least significant bit of the first byte being bit 7, the most significant bit of the second byte being bit 8, and so on. A one bit encodes that the condition was detected, while a zero bit encodes that the condition was not detected. This object is useful for alerting an operator to specific warning or error conditions that may occur, especially those requiring human intervention. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: The product reports error conditions as follows: noPaper - A tray is empty and must be filled for printing to continue. hrDeviceStatus = eHdown; hrPrinterStatus = eHother; A critical alert is active. coverOpen -- A cover or door is open. hrDeviceStatus = eHdown; hrPrinterStatus = eHother; A critical alert is active. jammed -- A jam condition is preventing printing. hrDeviceStatus = eHdown; hrPrinterStatus = eHother; A critical alert is active. offline -- Printer is offline and will not accept new print jobs until it is online. This condition is rare in the and may indicate some other error. hrDeviceStatus = eHdown; hrPrinterStatus = eHother; A critical alert is active. serviceRequested -- Any status or error condition not listed above. These fall into two categories: (1) If the condition prevents printing, the 'offline' bit is also set and status values are as for offline. i.e.: hrDeviceStatus = eHdown; hrPrinterStatus = eHother; A critical alert is active. (2) If the condition does not prevent printing the status values are: hrDeviceStatus = eHwarning; hrPrinterStatus = eHidle or eHprinting; A non-critical alert is active. lowToner -- The product can report this condition. noToner -- The product can report this condition." ::= { hrPrinterEntry 2 } npCRCTable OBJECT-TYPE SYNTAX SEQUENCE OF NpCRCEntry ACCESS not-accessible STATUS current DESCRIPTION "" ::= { npCard 15 } npCRCEntry OBJECT-TYPE SYNTAX NpCRCEntry ACCESS not-accessible STATUS current DESCRIPTION "" ::= { npCRCTable 1 } npCRCIndex OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "" ::= { npCRCEntry 1 } npCRCText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS current DESCRIPTION "" ::= { npCRCEntry 2 } npCRCChannel OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "" ::= { npCRCEntry 3 } inetTrapDestinationNum OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "Total number of ACTIVE rows in the inetTrapDestination table." ::= { inetTrapDestination 1 } inetTrapDestinationTable OBJECT-TYPE SYNTAX SEQUENCE OF InetTrapDestinationEntry ACCESS not-accessible STATUS current DESCRIPTION "List of inetTrap destinations to which the agent sends traps." ::= { inetTrapDestination 2 } inetTrapDestinationEntry OBJECT-TYPE SYNTAX InetTrapDestinationEntry ACCESS not-accessible STATUS current DESCRIPTION "Entries are inetAddress Specific sequence of trap destination parameters." ::= { inetTrapDestinationTable 1 } inetTrapRowIndex OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "Row Index of the inetTrapDestination table" ::= { inetTrapDestinationEntry 1 } inetTrapRowStatus OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS current DESCRIPTION "Individual Row Status 1 - Row is Active - Row is activated and ready. 2 - Not-In-Service - Row is suspended. 3 - Not Ready - Row is not activated and still needs some columnar values to move to ready state. 4 - Create and Go - This is set when the client uses multivarbind request to configure the trap table. 5 - Create and Wait - This is set when the client does sequential configuration of the trap table. 6 - Destroy - This is set when the client wants to delete the row from the table. " ::= { inetTrapDestinationEntry 2 } inetTrapAddressType OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "Protocol family for trap. Possible values: ipv4(1) An IPv4 address as defined by the InetAddressIPv4 textual convention. ipv6(2) An IPv6 address as defined by the InetAddressIPv6 textual convention. dns(16) A DNS domain name as defined by the InetAddressDNS textual convention." ::= { inetTrapDestinationEntry 3 } inetTrapAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "IPv4/IPv6/FQDN address of trap destination node." ::= { inetTrapDestinationEntry 4 } inetTrapPort OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS current DESCRIPTION "Port number of the inetTrap Destination to which the trap is sent." ::= { inetTrapDestinationEntry 5 } inetTrapCommunityName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "Trap community name specified in the trap packet." ::= { inetTrapDestinationEntry 6 } inetTrapVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "Trap version, one of the following 0 = snmpV1 1 = snmpV2 3 = Inform Default is 1 = snmpV2. This value remains persistent through a powercycle." ::= { inetTrapDestinationEntry 7 } inetTrapStyle OBJECT-TYPE SYNTAX INTEGER {selectable-pml-traps(1), aps-and-general-or-nrdpe-traps(2), both-of-the-above(3)} ACCESS read-write STATUS current DESCRIPTION "This OID is read-write. If the user wants to receive only the PML traps, then trapStyle can be set to 1. If the user wants to receive only APS and General or NOT-READY-DESTINATION-PRINT-ENGINE traps, then trapStyle can be set to 2. If the user wants to receive the both kinds of above traps, then trapStyle can be set to 3." ::= { inetTrapDestinationEntry 8 } inetTrapPMLOids OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "This OID is a read-write. This will have tokens of PML trappable OIDs. Each token (OID) will be separated by a semi-colon. If a trap destination entry is registered for only APS and general/NRDPE traps, then the pmlTrapOids OID will be a NULL string." ::= { inetTrapDestinationEntry 9 } inetTrapErrorValue OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "Gives the error value in case if the server is not able to send the traps to the configured trapDestination entry. It will be set to below defined error values if there the agent finds any error while dispatching a trap. 10 - Invalid value for rowStatus. Should be 1, 2, 3 or 6. 11 - Ivalid value for InetTrapAddressType. Should be 1, 2 or 16. 12 - Invalid for IP Address or FQDN. 13 - Ivalid value for inetTrapPort. Should be greater than 0 or less than 65536. 14 - Invalid valur for inetTrapCommunityName. 15 - Invalid value for inetTrapVersion. Should be 0, 1 or 3. 16 - Invalid value for inetTrapStyle. Should be either 1, 2 or 3. 17 - Unable to resgister SOME or ALL PML trappable OIDs. 51 - InetTrapAddressType & InetTrapAddress does not macth. 52 - It is a Duplicate entry. 53 - Unable to move the row to ACTIVE state because of insufficient/invalid entries. 80 - Unable to resolve name: no DNS server. 81 - Unable to resolve name: no DNS records present for name. 82 - Unable to resolve name: no dns records matching FQDN Resolution Value. " ::= { inetTrapDestinationEntry 10 } inetTrapTest OBJECT-TYPE SYNTAX Integer32 ACCESS write-only STATUS current DESCRIPTION "Causes agent to send an snmp trap to hosts registered in the trap destination table. Value specified will be used as the specific trap id." ::= { inetTrapDestination 3 } inetTrapFilterDelay OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS current DESCRIPTION "The purpose of the trap filter feature is to prevent multiple traps of the same specificTrapId to be sent within a short period of time. This object assigns the period of time within which a duplicate trap will be blocked. This value is in 1/10 second intervals and the default value is set to 50 corresponding to 5 seconds. This value remains persistent through a powercycle." ::= { inetTrapDestination 4 } inetTrapBaseTimeout OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS current DESCRIPTION "Applicable only if trapVersion is set to Inform. Units are 1/10 second intervals. Default is 2 corresponding to 200 milliseconds. This value corresponds to the time of the first retry following the initial inform request. Additional retries are sent at times corresponding to the retry number multiplied by the inetTrapBaseTimeout. This value remains persistent through a powercycle." ::= { inetTrapDestination 5 } inetTrapRetryNum OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS current DESCRIPTION "Applicable only if trapVersion is set to Inform. This is the maximum number of inform retries that will be sent to this destination. Retries are sent if no inform reply is received within the timeout value. The timeout value is calculated as described under inetTrapBaseTimeout. This value remains persistent through a powercycle." ::= { inetTrapDestination 6 } inetTrapFQDNResolution OBJECT-TYPE SYNTAX INTEGER {resolve-for-IPv4-address(1), resolve-for-IPv6-address(2), resolve-for-both(10)} ACCESS read-write STATUS current DESCRIPTION "The purpose of this field is to configure various options for resolving FQDN. If configured as 1 - then FQDN names will be resolved for IPv4 addresses only If configured as 2 - then FQDN names will be resolved for IPv6 addresses only. If configured as 10 - then FQDN names will be resolved for both IPv4 and IPv6 addresses." ::= { inetTrapDestination 7 } inetTrapFQDNMultipleAddressBehavior OBJECT-TYPE SYNTAX INTEGER {send-to-first-resolved-address(1), send-to-all-resolved-address(2)} ACCESS read-write STATUS current DESCRIPTION "1 - Send traps to the first resolved address 2 - Send traps to all resolved address. " ::= { inetTrapDestination 8 } inetTrapUseDNSCache OBJECT-TYPE SYNTAX INTEGER {enable(1), disable(0)} ACCESS read-write STATUS current DESCRIPTION "Depending upon the value of this field resolution of FQDN will happen everytime when a trap is sent." ::= { inetTrapDestination 9 } trapDestinationNum OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "The number of trap destinations." ::= { trapDest 1 } trapDestinationTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapDestinationEntry ACCESS not-accessible STATUS current DESCRIPTION "Protocol specific list of destinations to which the agent sends traps." ::= { trapDest 2 } trapDestinationEntry OBJECT-TYPE SYNTAX TrapDestinationEntry ACCESS not-accessible STATUS current DESCRIPTION "Entries are a protocol specific sequence of trap destination parameters." ::= { trapDestinationTable 1 } trapTest OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS current DESCRIPTION "Causes agent to send an snmp trap to hosts registered in the trap destination table. Value specified will be used as the specific trap id." ::= { trapDest 3 } trapSource OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "Sets the agent internal source for traps. Possibilities are as follows: 0 = ALL_TRAPS_ON 1 = ASYNC_PERIPHERAL_STATUS traps only 2 = proprietary PML traps only 3 = alert table traps only This object was changed to read-only to accommodate the SNMPv3 Notifiaction tables requirement to recieve all traps. SNMPv3 tags are used to filter SNMP Trap sources." ::= { trapDest 4 } trapFilterDelay OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS current DESCRIPTION "The purpose of the trap filter feature is to prevent multiple traps of the same specificTrapId to be sent within a short period of time. This object assigns the period of time within which a duplicate trap will be blocked. This value is in 1/10 second intervals and the default value is set to 50 corresponding to 5 seconds. This value remains persistent through a powercycle." ::= { trapDest 5 } trapFQDNNum OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "Number of trapFQDNTable rows." ::= { trapDest 6 } trapFQDNTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapFQDNEntry ACCESS not-accessible STATUS current DESCRIPTION "The trap destination entries can be mapped to destination's FQDN name in this table." ::= { trapDest 7 } trapFQDNEntry OBJECT-TYPE SYNTAX TrapFQDNEntry ACCESS not-accessible STATUS current DESCRIPTION "An FQDN destination entry indexed by the destination's IP address." ::= { trapFQDNTable 1 } trapIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS current DESCRIPTION "The trap destination IP address." ::= { trapFQDNEntry 1 } trapFQDN OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "The trap destination's FQDN. This will be resolved to IP address(es) at trap destination time." ::= { trapFQDNEntry 2 } setCommunityName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "This object controls access of snmp read-write requests. Factory default configuration provides authentication of incoming packets with community names: internal and public. This object overrides the factory default settings so that the factory default setttings no longer work. This object returns SET or NOT_SET." ::= { community 1 } getCommunityName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "This object controls access of snmp read requests. Factory default configuration provides authentication of incoming packets with community names: internal and public. This object provides access in addition to the factory default settings. If set, then authentication will succeed with any of the following community names: internal, public, getCommunityName, or setCommunityName. This object returns SET or NOT_SET." ::= { community 2 } npSysStatusMessage OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS current DESCRIPTION "A status string reflecting the current state of the card and peripheral." ::= { npSys 2 } npSysModelNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS current DESCRIPTION "The HP model number of the device." ::= { npSys 10 } npSysNetworkConnectors OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "This object describes the network connectors supported by the device. The value is a bit mask. A set bit indicates the connector is supported. Bit Value Connector 0 0x01 Ethernet, BNC 1 0x02 Ethernet, AUI 2 0x04 Ethernet, RJ-45 3 0x08 TokenRing, DB-9 4 0x10 TokenRing, RJ-45 5 0x20 LocalTalk 6 0x40 100VG, RJ-45 7 0x80 100T, RJ-45" ::= { npSys 11 } npSysCardServices1 OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "This object is a bitmap showing what services are available on the card. Bit 0 - IPX/SPX/NCP protocol stack Bit 1 - IP/TCP protocol stack Bit 2 - LLC/DLC protocol stack Bit 3 - Ethertalk protocol stack Bit 4 - IPv6 protocol stack Bit 5 - IPSec protocol stack Bits 6 - 11 Reserved Bit 12 - LPD print services Bit 13 - FTP print services Bit 14 - Port 9100 print services Bit 15 - IPP print services Bits 16 - 23 Reserved Bit 24 - Queue Server Bindery Bit 25 - Queue Server NDS Bit 26 - Remote Printer Bit 27 - SPX Direct Mode Bit 28 - DLC Print Services Bit 29 - EtherTalk Print Services Bits 30 - 31 Reserved" ::= { npSys 16 } npSysCardServices2 OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "This object is a bitmap showing what services are available on the card. Bit 0 - XIP2 Bit 1 - PML Get/Set Bit 2 - PML Traps Bit 3 - Scan to Web Browser Bit 4 - Scan to Email Bit 5 - MFP Scan Support Bits 6 - 11 Reserved Bit 12 - Telnet API Bit 13 - Web API Bit 14 - SNMP V2 Bit 15 - SNMP Traps Bit 16 - Download Bit 17 - TFTP Bit 18 - RCFG Bit 19 - SLP Bit 20 - Syslog Bit 21 - DHCP Bit 22 - BOOTP Bit 23 - RARP Bit 24 - SNMP V3 Bit 25 - SSL Functionality Bit 26 - Auto IP Bit 27 - SNMP V3 SHA-1 & AES-128 support. Bits 28 - 31 Reserved" ::= { npSys 17 } npSysCardServices3 OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "This object is a bitmap showing what services are available on the card. Bit 0 - 100T Bit 1 - Token Ring 802.5 Bit 2 - 802.11b Bit 3 - 80211.a Bit 4 - Bluetooth Bits 5 - 11 Reserved Bit 12 - EIO. For embedded Jetdirect this bit will be 1. Bit 13 - LIO Bit 14 - USB Bit 15 - Firewire Bit 16 - TCP Download Bits 17 - 31 Reserved" ::= { npSys 22 } npConnsIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS current DESCRIPTION "Remote IP address of the node currently connected to the card. Zero if no connection is active." ::= { npConns 11 } npCfgSource OBJECT-TYPE SYNTAX INTEGER {manual-one(1), bootp-two(2), manual-three(3), bootp-four(4), dhcp(5), not-configured(6), default-config(7), rarp(8), read-only(9), auto-ip(10)} ACCESS read-write STATUS current DESCRIPTION "This object indicates how the device obtained its IP configuration." ::= { npCfg 1 } npCfgYiaddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "The IP address assigned to the card from the BOOTP reply yiaddr field." ::= { npCfg 2 } npCfgSiaddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS current DESCRIPTION "The IP address of the TFTP server from the BOOTP reply siaddr field." ::= { npCfg 3 } npCfgLogServer OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "The IP address of the Syslog Server. If set via BOOTP (Tag: 7 field, lg= ) then SNMP set will fail. If not set via BOOTP then SNMP set will succeed. Value saved across warm boot power cycles. BOOTP will always overwrite SNMP set values." ::= { npCfg 5 } npCfgSyslogFacility OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "This specifies the facility identifier used in syslog messages generated by the card." ::= { npCfg 6 } npCfgAccessState OBJECT-TYPE SYNTAX INTEGER {allowed(1), not-allowed(2)} ACCESS read-only STATUS current DESCRIPTION "An indication of whether or not the requesting host is allowed to connect to the card as dictated by the access list." ::= { npCfg 7 } npCfgAccessListNum OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "The number of access list entries." ::= { npCfg 8 } npCfgAccessListTable OBJECT-TYPE SYNTAX SEQUENCE OF NpCfgAccessListEntry ACCESS not-accessible STATUS current DESCRIPTION "List of access addresses and masks." ::= { npCfg 9 } npCfgAccessListEntry OBJECT-TYPE SYNTAX NpCfgAccessListEntry ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains an access address and mask." ::= { npCfgAccessListTable 1 } npCfgAccessListIndex OBJECT-TYPE SYNTAX Integer32 (0..9) ACCESS read-only STATUS current DESCRIPTION "Index to the configuration access list table." ::= { npCfgAccessListEntry 1 } npCfgAccessListAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "The Access List Address contains the list of hosts or network of hosts that are allowed to connect to the print server over ip. When setting this object npCfgAccessListAddrMask should also be set in the same varbind packet. NpCfgAccessListAddress should always preceed npCfgAccessListAddrMask in the set packet. If npCfgAccessListAddrMask is not set, the default value of 255.255.255.255 will be assigned to npCfgAccessListAddrMask for that particular npCfgAccessListAddress entry. Duplicate host addresses are possible and, once set, it is not possible to change any particular row other than to clear the Access List Table. To clear the Access List Table set npCfgAccessListAddress to 0.0.0.0. This table has a maximum of 10 rows." ::= { npCfgAccessListEntry 2 } npCfgAccessListAddrMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "Address mask used to help determine whether or not a given IP address is allowed access to the print server. An IP address is allowed access if (Addr & AddrMask) == (IP & AddrMask). A set of this object may only be done if npCfgAccessListAddress preceeds it in the same varbind packet." ::= { npCfgAccessListEntry 3 } npCfgSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "The subnet mask associated with the IP address of this card." ::= { npCfg 12 } npCfgDefaultGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "This variable contains the IP address of the default router for this card." ::= { npCfg 13 } npCfgDomainName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "The print server domain name." ::= { npCfg 16 } npCfgIPP OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS current DESCRIPTION "Below are the different values accepted by this OID. 0 - Disable IPP and IPP-S 1 - Enable IPP and IPP-S 2 - Enable IPP-S only 3 - Enable IPP only " ::= { npCfg 18 } npCfgWINSNameServerIdPri OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "Primary name server for NetBIOS over TCP/IP." ::= { npCfg 22 } npCfgPasswd1Verify OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "Compares string value to passwd1 and returns OK if match, GENERAL ERROR if doesn't match." ::= { npCfg 28 } npCfgPasswd1 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS current DESCRIPTION "Password for root or administrator. Get request returns either 'SET' or 'NOT_SET'." ::= { npCfg 29 } npCfgBanner OBJECT-TYPE SYNTAX Integer32 (0..1) ACCESS read-write STATUS current DESCRIPTION "Line Printer Daemon Protocol (LPD) banner page per I/O port. (0) = Disabled (1) = Enabled Enabled by default." ::= { npCfg 31 } npCfgLinkType OBJECT-TYPE SYNTAX INTEGER {autoNegotiate(1), full10T(2), half10T(3), full100T(4), half100T(5), auto100T(6), full1000T(7)} ACCESS read-write STATUS current DESCRIPTION "Network link speed and communication mode." ::= { npCfg 35 } npCfgSnmpDefaultReadCmnty OBJECT-TYPE SYNTAX Integer32 (0..1) ACCESS read-write STATUS current DESCRIPTION "Controls Default Read Community Name access. (0) = Disabled, i.e., default get community names FAIL to access target. (1) = Enabled, i.e., default get community names SUCCEED to access target." ::= { npCfg 40 } npCfgBonjourServiceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "The name by which all the Jetdirect services will be advertised by Multicast Domain Name System (Bonjour). Must set a non empty string" ::= { npCfg 44 } npCfgBonjourDomainName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS current DESCRIPTION "The name used as the 'target name' in the DNS SRV records by Multicast Domain Name System (Bonjour)." ::= { npCfg 46 } npCfgIPv6DomainName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "IPv6 Domain Name." ::= { npCfg 49 } npCfgIPv6ConfigState OBJECT-TYPE SYNTAX INTEGER {ipv6-going-down(0), ipv6-is-up(1)} ACCESS read-only STATUS current DESCRIPTION "IPv6 stack status event; IPv6 enabled/disabled." ::= { npCfg 50 } npCfgIPv6DNSAddr1 OBJECT-TYPE SYNTAX InetAddress ACCESS read-write STATUS current DESCRIPTION "IPv6 DNS Address, priority 1." ::= { npCfg 56 } npCfgIPv6DNSAddr2 OBJECT-TYPE SYNTAX InetAddress ACCESS read-write STATUS current DESCRIPTION "IPv6 DNS Address, priority 2." ::= { npCfg 57 } npCfgIPConfigPrecedence OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "Allows to set uniform rules for parameter overwrite by different configuration methods. 0 - Manual 1 - TFTP 2 - DHCPv4/Bootp 3 - DHCPv6 - only if ipv6 is supported 3/4 - Default - 4 if ipv6 is supported otherwise 3 The set string should be 0:1:2:3:4 (or 0:1:2:3 when ipv6 is not supported) or any colon separated combination of the 5 (or 4) integral values. The string should contain all integral values atleast and atmost once." ::= { npCfg 59 } npCfgPortConfig OBJECT-TYPE SYNTAX INTEGER {half10T(10), full10T(11), half100T(12), full100T(13), full1000T(19)} ACCESS read-only STATUS current DESCRIPTION "Network link speed and communication mode." ::= { npCfg 65 } npCfgWiFiDirectChannelNumber OBJECT-TYPE SYNTAX INTEGER(1..13) ACCESS read-write STATUS current DESCRIPTION "The WiFi channel number used for Wireless/Wi-Fi Direct. Region Allowed Channels ------------------- ---------------- US & Worldwide Safe 1 - 11 Rest of the world 1 - 13 If wireless station is enabled, this setting is ignored and the channel used is determined by the AP to which the device is associated to. Default channel is 6. " ::= { npCfg 85 } npCfgWiFiDirectSSIDPrefix OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS current DESCRIPTION " The prefix of the network name (SSID) used for Wireless/Wi-Fi Direct. The value is 'HP-Print-XY-' where XY is the last two hex characters from the wireless MAC address. On products supporting Wi-Fi Direct, the value is 'DIRECT-XY-HP '. The prefix is read-only. The value of this object is prefixed to the value of npCfgWiFiDirectSSIDSuffix to form the complete SSID. " ::= { npCfg 86 } npCfgWiFiDirectSSIDSuffix OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION " The modifiable suffix of the network name (SSID) used for Wireless/Wi-Fi Direct. The default is ' ', but it can be different depending on printer family. The value of this object is concatenated to the value of npCfgWiFiDirectSSIDPrefix to form the complete SSID. " ::= { npCfg 87 } npCfgWiFiDirectConnectionSecurity OBJECT-TYPE SYNTAX INTEGER {automatic(0), manual(1), advanced(2)} ACCESS read-write STATUS optional DESCRIPTION "This is used to select the Wi-Fi Direct connection security method which differentiates how the connection is done between a mobile client and the printer. The following values are defined: Automatic ( 0 ) Manual ( 1 ) Advanced ( 2 ) Automatic - Printer will accept all Wi-Fi Direct initiated connections without requiring the user to push a button on the printer. The user may have to enter a PIN, provided by the printer, if the mobile device requests PIN method. Manual - Wi-Fi Direct clients require printer interaction to connect. The user has to push a button on the printer or enter a PIN into the mobile device to connect depending on the method requested by mobile device. Advanced - This mode disables Wi-Fi Direct, switches to Wireless Direct and allows configuration of advanced settings. " ::= { npCfg 88 } npTcpTFTPFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS current DESCRIPTION "The TFTP configuration file name." ::= { npTcp 9 } npTcpTFTPServerId OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS current DESCRIPTION "TFTP server from which configuration information is obtained." ::= { npTcp 10 } npTcpSyslogMax OBJECT-TYPE SYNTAX Integer32 (0..1000) ACCESS read-write STATUS current DESCRIPTION "Maximum number of syslog packets to be sent per minute. 0 = Disabled." ::= { npTcp 11 } npTcpAppSyslogPriority OBJECT-TYPE SYNTAX Integer32 (0..8) ACCESS read-write STATUS current DESCRIPTION "Priority below which the syslog messages will not be sent. Valid priority levels = 0 through 7. Disabled = 8." ::= { npTcp 12 } npCtlReconfig OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS current DESCRIPTION "Writing any value to this variable causes the card to reconfigure itself by doing the BOOTP/TFTP configuration activity." ::= { npCtl 8 } npCtlProtocolSet OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS current DESCRIPTION "This is a 4 byte integer value. The least significant bytes represent the protocols on the card. A value of '1' indicates a protocol that is enabled. A value of '0' indicates a protocol that is disabled. The 32-bit protocol enable 'structure' is defined as: bits 31-28: Number of I/O channels/protocols present (NUM_CHAN) bits 27-24: Number of I/O channels which may operate concurrently (NUM_OP_CHAN) bits 23-16: unused, reserved bits 15-1: Individual I/O channel/protocol enable bits, 0 == disable, 1 == enable MIO_IOCHAN_NOVELL bit 1 MIO_IOCHAN_LLC bit 2 MIO_IOCHAN_TCP bit 3 MIO_IOCHAN_ATALK bit 4 MIO_IOCHAN_IPV6 bit 5 bit 0: When NUM_OP_CHAN == 1, auto-protocol select enable bit, 0 == disable, 1 == enable (APS_ON)" ::= { npCtl 9 } npCtlSNMPEnableDisable OBJECT-TYPE SYNTAX Integer32 (0..1) ACCESS read-write STATUS current DESCRIPTION "0 = SNMP disabled 1 = SNMP enabled If SNMP is enabled, setting this object to 0 will disable SNMP on the print server. Once disabled it is not possible to enable SNMP via SNMP. When enabled, a get request will return 1. SNMP may be enabled via a different user interface, such as telnet or the print server Embedded Web Server." ::= { npCtl 14 } npCtlTelnet OBJECT-TYPE SYNTAX Integer32 (0..1) ACCESS read-write STATUS current DESCRIPTION "Configure Telnet service. (0) = Telnet disabled (1) = Telnet enabled" ::= { npCtl 19 } npCtlFTP OBJECT-TYPE SYNTAX Integer32 { printDisable-downloadDisable(0), printEnable-downloadEnable(1), printEnable-downloadDisable(2), printDisable-downloadEnable(3) } ACCESS read-write STATUS current DESCRIPTION "Configure File Transfer Protocol (FTP) service. (0) = Both FTP Print and Download Disabled (1) = Both FTP Print and Download Enabled (2) = FTP Print Enabled and FTP Download Disabled (3) = FTP Print Disabled and FTP Download Enabled " ::= { npCtl 20 } npCtlSLP OBJECT-TYPE SYNTAX Integer32 (0..1) ACCESS read-write STATUS current DESCRIPTION "Configure Service Location Protocol (SLP) service. (0) = SLP disabled (1) = SLP enabled" ::= { npCtl 21 } npCtlLPD OBJECT-TYPE SYNTAX Integer32 (0..1) ACCESS read-write STATUS current DESCRIPTION "Configure Line Printer Daemon Protocol (LPD) service. (0) = LPD disabled (1) = LPD enabled" ::= { npCtl 22 } npCtl9100 OBJECT-TYPE SYNTAX Integer32 (0..1) ACCESS read-write STATUS current DESCRIPTION "Configure TCP port 9100 printing. (0) = port 9100 printing disabled (1) = port 9100 printing enabled" ::= { npCtl 24 } npCtlSysLog OBJECT-TYPE SYNTAX Integer32 (0..1) ACCESS read-write STATUS current DESCRIPTION "Configure Syslog service. (0) = Syslog service disabled (1) = Syslog service enabled Enabled by default." ::= { npCtl 26 } npCtlSnmpVersionAccess OBJECT-TYPE SYNTAX INTEGER {snmpV1RW-snmpV3RW(1), snmpV1RO-snmpV3RW(2), snmpV1NoAccess-snmpV3RW(3), snmpV1RW-snmpV3NoAccess(4), snmpV1RO-snmpV3NoAccess(5)} ACCESS read-write STATUS current DESCRIPTION "Manages an SNMP version's read and write access to the MIB." ::= { npCtl 27 } npCtlSnmpV3InitAccount OBJECT-TYPE SYNTAX INTEGER {destroy(0), blockInitEncrypt(4)} ACCESS read-write STATUS current DESCRIPTION "Used to create initial SNMPv3 account. The following rules apply: 0 = clear init account, only if previously 0. 4 = Block init account, only cold reset will clear or use Web User interface. Setting this object to blocked (4) will block an initial account creation until a cold reset." ::= { npCtl 28 } npCtlBonjour OBJECT-TYPE SYNTAX Integer32 (0..1) ACCESS read-write STATUS current DESCRIPTION "Configure Multicast Domain Name Service. (0) = Bonjour disabled (1) = Bonjour enabled" ::= { npCtl 29 } npCtlNetworkConnectionMode OBJECT-TYPE SYNTAX INTEGER {auto-cable-detect(1), disable-radio(2), disable-wired(3)} ACCESS read-write STATUS current DESCRIPTION "This object controls the selection of the active network interface used for communication. This is applicable to products supporting dual wired and wireless network interfaces" ::= { npCtl 32 } npCtlIPSecurityPolicy OBJECT-TYPE SYNTAX INTEGER {disable(0), enable(1)} ACCESS read-write STATUS current DESCRIPTION "Disable IP Security (IPSec) or Firewall. Only disabling is allowed." ::= { npCtl 34 } npCtlWSDiscovery OBJECT-TYPE SYNTAX INTEGER {disable(0), enable(1)} ACCESS read-write STATUS current DESCRIPTION "Web Services Discovery enable/disable." ::= { npCtl 36 } npCtlWSPrint OBJECT-TYPE SYNTAX INTEGER {disable(0), enable(1)} ACCESS read-write STATUS current DESCRIPTION "Web Services Print enable/disable." ::= { npCtl 37 } npCtlLLMNR OBJECT-TYPE SYNTAX INTEGER {disable(0), enable(1)} ACCESS read-write STATUS current DESCRIPTION "Link-Local Multicast Name Resolution( LLMNR ) enable/disable." ::= { npCtl 38 } npCtlFpDot11WirelessState OBJECT-TYPE SYNTAX INTEGER {disable(0), enable(1)} ACCESS read-write STATUS current DESCRIPTION "Use for enabling and disabling Wireless Radio. The following values are defined: Disable = 0 Enable = 1 Default = 1(Enabled)" ::= { npCtl 47 } npCtlWiFiDirectSSIDBroadcast OBJECT-TYPE SYNTAX INTEGER {not-allowed(0), allowed(1)} ACCESS read-write STATUS current DESCRIPTION "This is used to allow or hide broadcasting of the SSID (Network name). Allowed(Default) = 1 Not Allowed = 0 Not Allowed (0) only takes effect when npCfgWiFiDirectConnectionSecurity is set to Advanced. " ::= { npCtl 57 } npCtlWiFiDirectHidePassphrase OBJECT-TYPE SYNTAX INTEGER {show(0), hide(1)} ACCESS read-write STATUS optional DESCRIPTION "This controls display of the Wireless passphrase on configuration reports/pages or on the control panel. Show = 0 Hide = 1 This object also controls whether or not the passphrase is included in the NFC record. Hide (1) only takes effect when npCfgWiFiDirectConnectionSecurity is set to Advanced " ::= { npCtl 58 } npCtlWiFiDirectHideSsid OBJECT-TYPE SYNTAX INTEGER {show(0), hide(1)} ACCESS read-write STATUS optional DESCRIPTION "This controls display of the network name (SSID) on configuration reports/pages or on the control panel. Show = 0 Hide = 1 Hide (1) only takes effect when npCfgWifiDirectConnectionSecurity is set to Advanced " ::= { npCtl 59 } npCtlAirPrintStatus OBJECT-TYPE SYNTAX INTEGER {disable(0), enable(1)} ACCESS read-write STATUS current DESCRIPTION " Use to Enabled/Disabled AirPrint functionality. Disable = 0 Enable(Default) = 1 " ::= { npCtl 68 } npCtlAllowRFC5746TLSSSLCompatibilityMode OBJECT-TYPE SYNTAX INTEGER {disable(0), enable(1)} ACCESS read-write STATUS current DESCRIPTION " Added to support RFC-5746. This OID can be use to enable/disable legacy SSL renegotiation. Disable = 0 Enable(Default) = 1 " ::= { npCtl 70 } npCtlWiFiDirectState OBJECT-TYPE SYNTAX INTEGER {disabled(0), enabled(1)} ACCESS read-write STATUS current DESCRIPTION "Configure 802.11 Wireless/Wi-Fi Direct functionality 0 = Wireless/Wi-Fi Direct is disabled 1 = Wireless/Wi-Fi Direct is enabled " ::= { npCtl 74 } npCtlGCPrint OBJECT-TYPE SYNTAX INTEGER {disable(0), enable(1), remove(2)} ACCESS read-write STATUS optional DESCRIPTION "Used to Enable/Disable/Remove(Hide) the GC Print service. Disable = 0 Enable (Default) = 1 Remove = 2 If disable is specified and the device is registered for Google Cloud Services, then the device will be unregistered. When remove is specified to an unregistered device, the UI aspects of the feature are hidden from end user, so that the user will not be able to see the Google cloud Print Service feature. When remove is specified to a registered device, the device will disable the feature and remove all user interfaces." ::= { npCtl 81 } npPortNumPorts OBJECT-TYPE SYNTAX Integer32 (0..255) ACCESS read-only STATUS current DESCRIPTION "The number of peripheral interfaces supported by this device." ::= { npPort 1 } npDHCPserver OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS current DESCRIPTION "IP address of DHCP server that provided this unit with an IP address via the DHCP protocol." ::= { npDhcp 2 } npDhcpFQDNBehavior OBJECT-TYPE SYNTAX INTEGER {present-JD-Behavior(0), rFC4702-compliant-Behavior(1)} ACCESS read-write STATUS current DESCRIPTION "This object defines the FQDN behavior in Jetdirect. Set this to ( 0 ) - Present Jetdirect Behavior ( 1 ) - RFC 4702 compliant behavior" ::= { npDhcp 4 } npWebProxyServerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "IP address or hostname of web proxy server." ::= { npWeb 12 } npWebProxyServerPort OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS current DESCRIPTION "IP port of web proxy server" ::= { npWeb 13 } npWebProxyUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "Proxy web user identification" ::= { npWeb 14 } npWebProxyUserPasswd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "Proxy web user password" ::= { npWeb 15 } npWebCheckACLforHTTP OBJECT-TYPE SYNTAX Integer32 (0..1) ACCESS read-write STATUS current DESCRIPTION "Configure checking of HTTP web connections against Access Control List. (0) = Disable ACL checking (1) = Enable ACL checking" ::= { npWeb 17 } npSecurityDot1xServerAuthProtocols OBJECT-TYPE SYNTAX INTEGER {eap-md5(1), eap-tls(2), leap(4), peap(8), ttls(16)} ACCESS read-write STATUS current DESCRIPTION " HP print servers support secured network access via Extensible Authentication Protocol (EAP) on an IEEE 802.1X network. The IEEE 802.1X standard provides a port-based authentication protocol where a network port allows or blocks use, depending on client authentication results. When using an 802.1X connection, the print server supports EAP with an authentication server, such as a remote authentication dial-in user service (RADIUS, RFC 2138) server. Brief description of few currently supported EAP/802.1X methods: 1) LEAP (lightweight EAP) is a proprietary Cisco Systems protocol that uses passwords for mutual authentication. It is used to authenticate access by a wireless client, typically a Cisco Aironet base station. 2) PEAP (Protected EAP) is a mutual authentication protocol that uses digital certificates for network server authentication and passwords for client authentication. For additional security, the authentication exchanges are encapsulated within transport layer security (TLS). Dynamic encryption keys are used for secure communications. 3) EAP-TLS (RFC 2716) is a mutual authentication protocol based on X.509v3–compliant digital certificates for authentication of both the client and the network authentication server. Dynamic encryption keys are used for secure communications. The following bitwise values are defined for this OID: None(0), EAP-MD5(1), EAP-TLS(2), LEAP(4), PEAP(8), TTLS(16) Note: 1) Not all of the above protocols might be supported on the printer. Use the OID npSecurityServicesSupported (1.3.6.1.4.1.11.2.4.3.20.27.0) to determine the supported protocols. " ::= { npSecurity 1 } npSecurityDot1xUsername OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION " Username required by EAP/802.1x Authentication methods. " ::= { npSecurity 2 } npSecurityDot1xAuthServerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION " Server ID relates to the Common Name that is returned in the subject of the Authentication Server Certificate and determines how print server should validate the authentication server. Server ID can be configured with a partial string (right-most characters) unless the “Require Exact Match” feature is enabled. Few examples: 1) Server id is blank: If the Authentication Server’s certificate is trusted, accept all Common Names returned in the Subject field of the Authentication Server certificate 2) Server id is configured and “Require Exact Match” is not enabled: If the Authentication server’s certificate is trusted, accept all Common Names returned in the Subject field of the Authentication Server certificate that have the configured server id as a rightmost subset. 3) Server id is configured and “Require Exact Match” is enabled: If the Authentication Server’s certificate is trusted, accept all Common Names with the exact name" ::= { npSecurity 3 } npSecurityPublicKey OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS current DESCRIPTION "The public key of a public/private key pair to be used by applications to set encrypted values." ::= { npSecurity 4 } npSecurityDot11EncryptedDot11NetworkName OBJECT-TYPE SYNTAX OCTET STRING ACCESS write-only STATUS current DESCRIPTION "The encrypted network name (SSID). Use the npSecurityPublicKey to encrypt this value. Setting this object will cause the card to reconfigure." ::= { npSecurity 5 } npSecurityEncryptedDot1xPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION " Password required by EAP/802.1x Authentication methods Use the npSecurityPublicKey (1.3.6.1.4.1.11.2.4.3.20.4.0) to encrypt this value using RSA public key encryption before performing snmpset. This is OID is logically write-only and a SnmpGet returns SET or NOT_SET. " ::= { npSecurity 6 } npSecurityDot11EncryptedWEPKeyTable OBJECT-TYPE SYNTAX SEQUENCE OF NpSecurityDot11EncryptedWEPKeyEntry ACCESS not-accessible STATUS current DESCRIPTION "Encrypted interface to the WEP Keys." ::= { npSecurity 7 } npSecurityDot11EncryptedWEPKeyEntry OBJECT-TYPE SYNTAX NpSecurityDot11EncryptedWEPKeyEntry ACCESS not-accessible STATUS current DESCRIPTION "Each row of the table gives a WEP Key" ::= { npSecurityDot11EncryptedWEPKeyTable 1 } npSecurityDot11EncryptedWEPKey OBJECT-TYPE SYNTAX OCTET STRING ACCESS write-only STATUS current DESCRIPTION "The encrypted WEP Key value. Use the npSecurityDot11PublicKey to encrypt this value. Setting this object will cause the card to reconfigure." ::= { npSecurityDot11EncryptedWEPKeyEntry 2 } npSecurityDot11SignalStrength OBJECT-TYPE SYNTAX INTEGER {level-1-TBD(1), level-2-TBD(2), level-3-TBD(3), level-4-TBD(4), level-5-TBD(5)} ACCESS read-only STATUS current DESCRIPTION "A weighted average over time of the signal strength between the access point and the print server in infrastructure mode. Not applicable when in ad hoc mode." ::= { npSecurity 8 } npSecurityDot11SSIDTable OBJECT-TYPE SYNTAX SEQUENCE OF NpSecurityDot11SSIDEntry ACCESS not-accessible STATUS current DESCRIPTION "List of discovered SSIDs." ::= { npSecurity 9 } npSecurityDot11SSIDEntry OBJECT-TYPE SYNTAX NpSecurityDot11SSIDEntry ACCESS not-accessible STATUS current DESCRIPTION "Each row of the table gives a discovered SSID value." ::= { npSecurityDot11SSIDTable 1 } npSecurityDot11SSID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS current DESCRIPTION "A discovered SSID value." ::= { npSecurityDot11SSIDEntry 2 } npSecurityDot11SSIDTableNumEntries OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "Displays the number of discovered SSIDs in the SSID Table." ::= { npSecurity 10 } npSecurityDot11SSLCertLoaded OBJECT-TYPE SYNTAX INTEGER {true(1), false(2)} ACCESS read-only STATUS current DESCRIPTION "Indicates if SSL certificate has been loaded." ::= { npSecurity 11 } npSecurityDot11TLSCertLoaded OBJECT-TYPE SYNTAX INTEGER {true(1), false(2)} ACCESS read-only STATUS current DESCRIPTION "Indicates if TLS Trusted CA certificate has been loaded." ::= { npSecurity 12 } npSecuritySnmpV3EncryptedUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS write-only STATUS current DESCRIPTION "The encrypted SNMPv3 User Name. Use the npSecurityPublicKey to encrypt this value. When setting this object, all three user account objects (npSecuritySnmpV3EncryptedUserName, npSecuritySnmpV3AuthKeyPassPhrase, and npSecuritySnmpV3PrivKeyPassPhrase) should also be set in the same multi-varbind request. Implementations may accept the objects in separate SNMP requests, or they may return a inconsistentValue (12) failure to indicate that other objects are required. If setting the objects individually is allowed, the User Account will not be installed until after all three objects have been set. This OID can only be SET if the inital SNMP V3 account is not created (i.e. the value of npCtlSnmpV3InitAccount is 0) If the user account is created successfully, it gets added as an entry in the usmUserTable (i.e. 1.3.6.1.6.3.15.1.2.2) " ::= { npSecurity 13 } npSecuritySnmpV3AuthKeyPassPhrase OBJECT-TYPE SYNTAX OCTET STRING ACCESS write-only STATUS current DESCRIPTION "The encrypted SNMPv3 Authentication passphrase or key . Use the npSecurityPublicKey to encrypt this value. When setting this object, all three user account objects (npSecuritySnmpV3EncryptedUserName, npSecuritySnmpV3AuthKeyPassPhrase, and npSecuritySnmpV3PrivKeyPassPhrase) should also be set in the same multi-varbind request. Implementations may accept the objects in separate SNMP requests, or they may return a inconsistentValue (12) failure to indicate that other objects are required. If setting the objects individually is allowed, the User Account will not be installed until after all three objects have been set. The other OID's related to SNMPv3 authentication are npSecuritySnmpV3AuthAlgorithm and npSecuritySnmpV3PassPhrase, please ensure that they are set appropriately. This OID can only be SET if the inital SNMP V3 account is not created (i.e. the value of npCtlSnmpV3InitAccount is 0) The values of npSecuritySnmpV3AuthAlgorithm and npSecuritySnmpV3PassPhrase must be set appropriately before setting the value of this OID. " ::= { npSecurity 14 } npSecuritySnmpV3PrivKeyPassPhrase OBJECT-TYPE SYNTAX OCTET STRING ACCESS write-only STATUS current DESCRIPTION "The encrypted SNMPv3 Privacy passphrase or key. Use the npSecurityPublicKey to encrypt this value. When setting this object, all three user account objects (npSecuritySnmpV3EncryptedUserName, npSecuritySnmpV3AuthKeyPassPhrase, and npSecuritySnmpV3PrivKeyPassPhrase) should also be set in the same multi-varbind request. Implementations may accept the objects in separate SNMP requests, or they may return a inconsistentValue (12) failure to indicate that other objects are required. If setting the objects individually is allowed, the User Account will not be installed until after all three objects have been set. The other OID's related to SNMPv3 encryption are npSecuritySnmpV3PrivAlgorithm and npSecuritySnmpV3PassPhrase, please ensure that they are set appropriately. This OID can only be SET if the inital SNMP V3 account is not created (i.e. the value of npCtlSnmpV3InitAccount is 0) The values of npSecuritySnmpV3PrivAlgorithm and npSecuritySnmpV3PassPhrase must be set appropriately before setting the value of this OID. " ::= { npSecurity 15 } npSecurityDot11BSSID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS current DESCRIPTION "The BSSID value (hardware address of the access point)." ::= { npSecurity 16 } npSecurityDot1xTunnelAuthBits OBJECT-TYPE SYNTAX INTEGER {eap-md5(1), eap-mschap(2), eap-mschapv2(4), mschap(8), mschapv2(16), eap-gtc(32)} ACCESS read-write STATUS current DESCRIPTION "The Dot1x Tunnel Authentication Bits. Bitwise field with the followings bits: Default All bits cleared EAP MD5 1 EAP MSCHAP 2 EAP MSCHAPv2 4 MSCHAP 8 MSCHAPv2 16 EAP GTC 32" ::= { npSecurity 17 } npSecurityDot1xIdentityCleartext OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "The Dot1x Identity in cleartext." ::= { npSecurity 18 } npSecurityDot1xExactMatchServerId OBJECT-TYPE SYNTAX TruthValue ACCESS read-write STATUS current DESCRIPTION " This OID allows us to configure the “Require Exact Match” feature which indicates how common name from a successfully authenticated server is considered. Few examples: 1) Server id is blank: If the Authentication Server’s certificate is trusted, accept all Common Names returned in the Subject field of the Authentication Server certificate 2) Server id is configured and “Require Exact Match” is not enabled: If the Authentication server’s certificate is trusted, accept all Common Names returned in the Subject field of the Authentication Server certificate that have the configured server id as a rightmost subset. 3) Server id is configured and “Require Exact Match” is enabled: If the Authentication Server’s certificate is trusted, accept all Common Names with the exact name " ::= { npSecurity 19 } npSecurityDot1xEncryptionStrength OBJECT-TYPE SYNTAX INTEGER {low(1), medium(2), high(3)} ACCESS read-write STATUS current DESCRIPTION " Encryption strength determines the minimum strength of the SSL tunnel by determining what ciphers are advertised by the print server in the TLS Client Hello packet. Low, Medium, High encryption strengths corresponds to various ciphers and key sizes. If FIPS is enabled, default encryption strength set is HIGH. " ::= { npSecurity 20 } npSecurityCertBuff OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS current DESCRIPTION "A 512 byte buffer of the print server certificate as indexed by npSecurityCertBuffIndex." ::= { npSecurity 21 } npSecurityCertBuffIndex OBJECT-TYPE SYNTAX INTEGER {block1(1), block2(2), block3(3), block4(4), block5(5), block6(6)} ACCESS read-write STATUS current DESCRIPTION "Indicates the index of the 512 byte block of the print server certificate to load into npSecurityCertBuff." ::= { npSecurity 22 } npSecuritySslRedirection OBJECT-TYPE SYNTAX INTEGER {redirectionEnabled(1), redirectionDisabled(2)} ACCESS read-write STATUS current DESCRIPTION "Setting this object causes the SSL redirection connection to be enabled or disabled." ::= { npSecurity 23 } npSecurityReset OBJECT-TYPE SYNTAX INTEGER {set(0), reset(1)} ACCESS read-write STATUS current DESCRIPTION "Setting this object causes security object to reset bact to the defaults." ::= { npSecurity 24 } npSecurityWebSpiEnable OBJECT-TYPE SYNTAX TruthValue ACCESS read-write STATUS current DESCRIPTION "This object enables/disables the Embedded Web Simple Printer Install feature." ::= { npSecurity 25 } npSecurityDot11WEPStrength OBJECT-TYPE SYNTAX INTEGER {not-set(1), strenth-40-bit(2), strenth-104-bit(3)} ACCESS read-only STATUS current DESCRIPTION "Indicates the encryption strength of the WEP keys." ::= { npSecurity 26 } npSecurityServicesSupported OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION " BITWISE indication of the security services this device supports. The following bits are defined: MD5 (0) TLS (1) TTLS (2) LEAP (3) PEAP (4) Reserved (5 - 15) WEP (16) WPA (17) AES (18) WPA2 (19) AUTO_FOR_WEP_SUPPORTED (20) AUTO_FOR_WPA_SUPPORTED (21) AUTO_FOR_ENCRYPTION_SUPPORTED (22) Reserved (23 - 31) " ::= { npSecurity 27 } npSecurityDot11Encryption OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS current DESCRIPTION "802.11 encryption method currently enabled. The following values are defined: NONE (0x00) SSN/WEP (0x01) TKIP (0x02) AES (0x03) AUTO (0x04) Reserved (5 - 31) It is advised not to use dot11PrivacyInvoked OID anymore, instead use npSecurityDot11Encryption. Since Jetdirect updates the same variable when the set happens through any of the two OIDs and npSecurityDot11Encryption is more versatile, it is recommended to use this OID. " ::= { npSecurity 28 } npSecurityDot11MulticastCipher OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS current DESCRIPTION "BITWISE indication of the multicast cipher method currently enabled. At minimum, one bit must be set. The following bits are defined: WEP (0) WPA (1) Reserved (2 - 31)" ::= { npSecurity 29 } npSecurityDot11BeaconTableNumEntries OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "Displays the number of discovered SSIDs in the DOT11 Beacon Table." ::= { npSecurity 34 } npSecurityDot11OpenSSIDEnabled OBJECT-TYPE SYNTAX TruthValue ACCESS read-only STATUS current DESCRIPTION "Indicates if the Open SSID is enabled (Spirit-only)." ::= { npSecurity 35 } npSecurityDot11EncryptedWPAConfigPSKPassPhrase OBJECT-TYPE SYNTAX OCTET STRING ACCESS write-only STATUS current DESCRIPTION "The encrypted WPA Config PSK PassPhrase. Use the npSecurityPublicKey to encrypt this value" ::= { npSecurity 36 } npSecurityDot11DataRate OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "Current wireless network data rate" ::= { npSecurity 37 } npSecurityDot11ScanComplete OBJECT-TYPE SYNTAX INTEGER {true(1), false(2)} ACCESS read-write STATUS current DESCRIPTION "Used to control scan for SSIDs in the wireless network. Set to false to initiate a scan. A value of true indicates the completion of the scan" ::= { npSecurity 38 } npSecurityDot11RoamThreshold OBJECT-TYPE SYNTAX INTEGER {no-signal(1), very-weak-signal(2), weak-signal(3)} ACCESS read-write STATUS current DESCRIPTION "Used to control roaming by the wireless radio. The radio on the print server will roam or try to find an access point with a stronger signal once the signal strength from the associated access point reaches the specified roam threshold level." ::= { npSecurity 39 } npSecuritySslEncryptionStrength OBJECT-TYPE SYNTAX INTEGER {low(1), medium(2), high(3)} ACCESS read-write STATUS current DESCRIPTION "The SSL Encryption Strength. Setting to Low, Medium or High decides the set of Cipher Suites that would be supported by the device." ::= { npSecurity 40 } npSecurityDot11InstantVerification OBJECT-TYPE SYNTAX INTEGER {disable(0), enable(1)} ACCESS read-write STATUS current DESCRIPTION "Enable and disable wireless instant verification. (0) = Disable (1) = Enable" ::= { npSecurity 41 } npSecurityDot11DynamicEncryption OBJECT-TYPE SYNTAX INTEGER {nONE(0), bASIC(1), wPA(2), wPA2(3), aUTO(4)} ACCESS read-write STATUS current DESCRIPTION "WPA mode. (0x00) = NONE (0x01) = BASIC (0x02) = WPA (0x03) = WPA2 (0x04) = AUTO" ::= { npSecurity 42 } npSecurityDot11LinkAuthentication OBJECT-TYPE SYNTAX INTEGER {open(1), shared-key(2), leap(128), auto(143)} ACCESS read-write STATUS current DESCRIPTION "DOT11 Link Authentication modes. (1) = OPEN (2) = SHARED-KEY (128) = LEAP (143) = AUTO We can set the Link Authentication using the object dot11AuthenticationAlgorithmsEnable ( OID: 1.2.840.10036.1.2.1.3.x ) Since the dot11AuthenticationAlgorithsmEnable object does not supports setting of AUTO option, we provide this object. Through this OID you can set to any one of the above options. Whereas using the dot11AuthenticationAlgorithmsEnable object we can set either OPEN OR SHARED mode only." ::= { npSecurity 43 } npSecuritySnmpV3AuthAlgorithm OBJECT-TYPE SYNTAX INTEGER {md5(2), sha-1(3)} ACCESS read-write STATUS current DESCRIPTION "Indicates the Authentication Algorithm used. It can have the value MD5 or SHA-1. This key will have a default value set to MD5. The following values are defined: MD5 2 (Default) SHA-1 3 This OID can only be SET if the inital SNMP V3 account is not created (i.e. the value of npCtlSnmpV3InitAccount is 0) " ::= { npSecurity 44 } npSecuritySnmpV3PrivAlgorithm OBJECT-TYPE SYNTAX INTEGER {des(2), aes-128(3)} ACCESS read-write STATUS current DESCRIPTION "Indicates the Privacy Algorithm used. It can have the value DES or AES-128. This key will have a default value set to DES. The following values are defined: DES 2 (Default) AES-128 3 This OID can only be SET if the inital SNMP V3 account is not created (i.e. the value of npCtlSnmpV3InitAccount is 0) " ::= { npSecurity 45 } npSecurityWirelessDirectEncryptionMethod OBJECT-TYPE SYNTAX INTEGER {noSecurity(1), wpa(2)} ACCESS read-write STATUS current DESCRIPTION "This is used to select the encryption protocol in Wireless Direct Mode. The following values are defined: No Security ( 1 ) WPA ( 2 ) " ::= { npSecurity 51 } npSecurityWirelessDirectEncryptedPassPhrase OBJECT-TYPE SYNTAX OCTET STRING ACCESS write-only STATUS current DESCRIPTION " The WPA2 Passphrase or pre-shared key for secure Wireless Direct. The values allowed are 8 to 63 printable ASCII characters for passphrase or a 64 character hex value for pre-shared key. Use npSecurityPublicKey to encrypt this value. " ::= { npSecurity 55 } npSecurityDot1xFailSafe OBJECT-TYPE SYNTAX INTEGER {enable(1), disable(0)} ACCESS read-write STATUS current DESCRIPTION "After configuring 802.1x on the printer and switching it over to a secured network, if authentication is successful printer retains connectivity and if it fails it loses connectivity. In case of authentication failure, it does not acquire connectivity even when switched over to an unsecured network. 802.1x failsafe is a feature which allows printer to retain connectivity in a unsecured network even if authentication fails. Setting this OID to 1 enables this feature and setting to 0 disables this feature. Connect anyway (802.1x Fail-Safe) ( 1 ) Block network (secure failure) ( 0 ) " ::= { npSecurity 57 } npSecurityIppAuthentication OBJECT-TYPE SYNTAX INTEGER {disable(0), enable(1)} ACCESS read-write STATUS current DESCRIPTION " IPP Authentication is a feature which provides 'HTTP Basic Authentication' for IPP Print-Jobs. Use this OID to Enable/Disable IPP Authentication. 0 - Disable IPP Authentication 1 - Enable IPP Authentication npSecurityIppAuthentication(1.3.6.1.4.1.11.2.4.3.20.61.0) is dependent on npSecurityIppAuthUsername(1.3.6.1.4.1.11.2.4.3.20.62.0) and npSecurityIppEncryptedAuthPassword(1.3.6.1.4.1.11.2.4.3.20.63.0). To enable npSecurityIppAuthentication, npSecurityIppAuthUsername and npSecurityIppEncryptedAuthPassword have to be first configured with valid values. Once enabled, npSecurityIppAuthentication can independently be disabled. npSecurityIppAuthUsername and npSecurityIppEncryptedAuthPassword will continue to retain their values. Errors returned: BAD VALUE(v1) or WRONG VALUE(v2/v3) will be returned when the OID is set with invalid value. GENERIC ERROR will be returned if the interdependency validation between the above three OIDs fails. " ::= { npSecurity 61 } npSecurityIppAuthUsername OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION " IPP Authentication is a feature which provides 'HTTP Basic Authentication' for IPP Print-Jobs. Use this OID to configure the IPP Authentication Username. Strings of length 1 to 31 and having any printable alphanumeric characters except ()<>@,;:\/[]?={} can be set. Setting with an empty octet string is equivalent to resetting the Username to NULL. npSecurityIppAuthUsername(1.3.6.1.4.1.11.2.4.3.20.62.0) and npSecurityIppEncryptedAuthPassword(1.3.6.1.4.1.11.2.4.3.20.63.0) have to be set in the same varbind. Use npSecurityIppAuthentication(1.3.6.1.4.1.11.2.4.3.20.61.0) to enable the feature once the username and password are configured. Errors returned: BAD VALUE(v1) or WRONG VALUE(v2/v3) will be returned when the OID is set with invalid value. GENERIC ERROR will be returned if the interdependency validation between the above three OIDs fails. " ::= { npSecurity 62 } npSecurityIppEncryptedAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION " IPP Authentication is a feature which provides 'HTTP Basic Authentication' for IPP Print-Jobs. Use this OID to configure the IPP Authentication Password. Strings of length 8 to 31 and having any printable alphanumeric characters except ()<>@,;:\/[]?={} can be set. Setting with an empty octet string is equivalent to resetting the Password to NULL. npSecurityIppAuthUsername(1.3.6.1.4.1.11.2.4.3.20.62.0) and npSecurityIppEncryptedAuthPassword(1.3.6.1.4.1.11.2.4.3.20.63.0) have to be set in the same varbind. Use npSecurityIppAuthentication(1.3.6.1.4.1.11.2.4.3.20.61.0) to enable the feature once the username and password are configured. Querying the OID will return 'SET' if the password is set and will return 'NOT_SET' if the password has not been configured. Errors returned: BAD VALUE(v1) or WRONG VALUE(v2/v3) will be returned when the OID is set with invalid value. GENERIC ERROR will be returned if the interdependency validation between the above three OIDs fails. NOTE: Use the npSecurityPublicKey(1.3.6.1.4.1.11.2.4.3.20.4.0) to encrypt the value before setting. " ::= { npSecurity 63 } gdStatusBytes OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "The number of valid bytes in the gdStatusEntry array." ::= { generalDeviceStatus 1 } gdStatusDisplay OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS current DESCRIPTION "The string diplayed on the peripheral front panel. For some peripherals, such as the HP LaserJet IIISi printer or HP DesignJet plotter, this is always a zero length string." ::= { generalDeviceStatus 3 } gdStatusId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS current DESCRIPTION "A formatted string of NVT ASCII charactersdescribing this peripheral." ::= { generalDeviceStatus 7 } gdStatusJobTimeout OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS obsolete ::= { generalDeviceStatus 10 } gdPasswords OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS current DESCRIPTION "This object is used as a 256 byte NVRAM area for JetAdmin. It is completely managed by JetAdmin. Initially it is initialized to all zeros. A coldboot will re-initialize to all zeros." ::= { generalDeviceStatus 13 } pmlTrapEnable OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS current DESCRIPTION "This OID is used to enable individual peripheral trappable objects through the print server." ::= { netPMLtrap 1 } pmlTrapDisable OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS current DESCRIPTION "This OID is used to disable individual peripheral trappable objects through the print server." ::= { netPMLtrap 2 } npNpiPaeClass OBJECT-TYPE SYNTAX INTEGER {printer(1), plotter(2), xStation(3)} ACCESS read-only STATUS current DESCRIPTION "The class assigned to the peripheral onto which this card is plugged." ::= { npNpiPeripheralAttributeEntry 2 } npNpiPaeIdentification OBJECT-TYPE SYNTAX INTEGER {laserjet-IIISI(1), laserjet-4SI(5)} ACCESS read-only STATUS current DESCRIPTION "The Identification number of the peripheral. These values are defined in the MIO spec. DesignJet, PaintJet XL300, and DesignJet/600 peripherals will identify themselves as LaserJet-IIIsi." ::= { npNpiPeripheralAttributeEntry 3 } npNpiCaeClass OBJECT-TYPE SYNTAX INTEGER {rs-232(1), centronics(2), csma-cd-network(3), token-ring-network(4), scsi(5), hpib(6), localtalk(7), hpna(8), usb(9), firewire(10), bluetooth(11), ieee802-11b(12)} ACCESS read-only STATUS current DESCRIPTION "The class of this network peripheral card." ::= { npNpiCardAttributeEntry 2 } gdStatusLineState OBJECT-TYPE SYNTAX Integer32 (0..255) ACCESS read-only STATUS current DESCRIPTION "This describes the line state of the peripheral. When non-zero, the peripheral is off-line. When zero the peripheral is on-line." ::= { gdStatusEntry 1 } gdStatusPaperState OBJECT-TYPE SYNTAX Integer32 (0..255) ACCESS read-only STATUS current DESCRIPTION "This describes the state of the paper on the peripheral. When non-zero, the peripheral has a paper problem. When zero, the peripheral does not have a paper problem." ::= { gdStatusEntry 2 } gdStatusInterventionState OBJECT-TYPE SYNTAX Integer32 (0..255) ACCESS read-only STATUS current DESCRIPTION "This describes the intervention state of the peripheral. When non-zero, the peripheral requires human intervention to continue working. When zero, it requires no assistance." ::= { gdStatusEntry 3 } gdStatusPeripheralError OBJECT-TYPE SYNTAX Integer32 (0..255) ACCESS read-only STATUS current DESCRIPTION "This is the error code from the peripheral." ::= { gdStatusEntry 6 } gdStatusPaperOut OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "This indicates that the peripheral is out of paper. off (0), paper-out-or-paper-mount (1), manual-paper-feed-needed (2) For some peripherals, such as the HP LaserJet IIISi printer or HP DesignJet plotter, this value is always a zero (0)." ::= { gdStatusEntry 8 } gdStatusPaperJam OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "This indicates that the peripheral has a paper jam. off (0), paper-jam(1) For some peripherals, such as the HP LaserJet IIISi printer or HP DesignJet plotter, this value is always a zero (0)." ::= { gdStatusEntry 9 } gdStatusTonerLow OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "This indicates that the peripheral has a low toner condition. off (0), toner-low (1), no-toner-cartridge (2) For some peripherals, such as the HP LaserJet IIISi printer or HP DesignJet plotter, this value is always a zero (0)." ::= { gdStatusEntry 10 } gdStatusPagePunt OBJECT-TYPE SYNTAX Integer32 (0..255) ACCESS read-only STATUS current DESCRIPTION "This indicates that the peripheral did not receive data fast enough to keep up with the print engine when generating a page. For some peripherals, such as the HP LaserJet IIISi printer or HP DesignJet plotter, this value is always a zero (0)." ::= { gdStatusEntry 11 } gdStatusMemoryOut OBJECT-TYPE SYNTAX Integer32 (0..255) ACCESS read-only STATUS current DESCRIPTION "This indicates that the peripheral did not have enough memory to render an image on a page. For some peripherals, such as the HP LaserJet IIISi printer or HP DesignJet plotter, this value is always a zero (0)." ::= { gdStatusEntry 12 } gdStatusIoActive OBJECT-TYPE SYNTAX Integer32 (0..255) ACCESS read-only STATUS current DESCRIPTION "This indicates that the peripheral is processing data from this I/O interface card. For some peripherals, such as the HP LaserJet IIISi printer or HP DesignJet plotter, this value is always a zero (0). For X.20.06 firmware and later firmware releases, this object is not relevant. In order not to break legacy applications which call this object in multi-varbind requests, this value is always zero (0)." ::= { gdStatusEntry 13 } gdStatusBusy OBJECT-TYPE SYNTAX Integer32 (0..255) ACCESS read-only STATUS current DESCRIPTION "This indicates that the peripheral is busy processing print/plot data. For some peripherals, such as the HP LaserJet IIISi printer or HP DesignJet plotter, this value is always a zero (0)." ::= { gdStatusEntry 14 } gdStatusWait OBJECT-TYPE SYNTAX Integer32 (0..255) ACCESS read-only STATUS current DESCRIPTION "This indicates that the peripheral is waiting for print/plot data to process. For some peripherals, such as the HP LaserJet IIISi printer or HP DesignJet plotter, this value is always a zero (0)." ::= { gdStatusEntry 15 } gdStatusInitialize OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "This indicates that the peripheral is initializing or warming up. off (0), initializing (1), warm-up(2) For some peripherals, such as the HP LaserJet IIISi printer or HP DesignJet plotter, this value is always a zero (0)." ::= { gdStatusEntry 16 } gdStatusDoorOpen OBJECT-TYPE SYNTAX Integer32 (0..255) ACCESS read-only STATUS current DESCRIPTION "This indicates that the peripheral cover or door is open. For some peripherals, such as the HP LaserJet IIISi printer or HP DesignJet plotter, this value is always a zero (0)." ::= { gdStatusEntry 17 } gdStatusPrinting OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "This indicates that the peripheral is printing or otherwise marking or moving paper. off (0), ordinary-page (1), test-fonts-config-or-start-page (2) For some peripherals, such as the HP LaserJet IIISi printer or HP DesignJet plotter, this value is always a zero (0)." ::= { gdStatusEntry 18 } gdStatusPaperOutput OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "This indicates that the peripheral has a paper output problem such as the output storage bin being full. off (0), output-storage-full (1) For some peripherals, such as the HP LaserJet IIISi printer or HP DesignJet plotter, this value is always a zero (0)." ::= { gdStatusEntry 19 } photo-access-card-error OBJECT-TYPE SYNTAX INTEGER { ePhotoCardAccessNoError(0), ePhotoCardSmartMediaUpsideDown(1), ePhotoCardMediaNotFullyInserted(2), ePhotoCardMoreThenOneInSlots(3), ePhotoCardReadError(4), ePhotoCardRemovedWhileReading(5), ePhotoCardBadFileWhilePrinting(6), ePhotoCardNotInSlot(7), ePhotoCardContainsNoPhotos(8), ePhotoCardWriteError(9), ePhotoCardRemovedWhileWriting(10), ePhotoCardUnknownError(999) } ACCESS read-only STATUS optional DESCRIPTION "Specifies the error reason for most recent unsucessful photo card access. Additional information: Specifies the error reason for most recent unsucessful photo card access." ::= { photo-job 2 } energy-star OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns or changes the Energy Star sleep value. If the value is greater than zero, then the device will go into energy saving sleep mode after the print engine has been idle for the number of seconds specified by this object. A value of zero means Energy Star is disabled and the device will not go to sleep based on print engine idle time. The value must be non-negative. Additional information: The product will always be in sleep mode when not processing data. This object will always return a value of 1." ::= { settings-system 1 } sleep-mode OBJECT-TYPE SYNTAX INTEGER { eFalse(1), eTrue(2) } ACCESS read-only STATUS optional DESCRIPTION "Returns eTrue if the device is in energy saving sleep mode, otherwise returns eFalse. Setting SLEEP-MODE to eFalse causes the device to wake up, if it is in sleep mode. Setting SLEEP-MODE to eTrue causes the device to go into sleep mode. Additional information: The product will always be in sleep mode except when either processing a print job or in an error state." ::= { settings-system 2 } service-password OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS optional DESCRIPTION "When set to the password value, other service related objects become 'visible' (i.e readable) and/or become writable. When written with any other value, the service related objects become 'hidden' (i.e. are no longer readable) and/or are not longer writable. The objects that can be effected by the SERVICE-PASSWORD object include: SERIAL-NUMBER and TOTAL-ENGINE-PAGE-COUNT. The password value, and the list of objects effected by the SERVICE-PASSWORD being set to the correct value, should be documented in the device POS. Additional information: The objects that can be effected by the SERVICE- PASSWORD are: SCANNER-JAM-PAGE-COUNT, SCANNER-ADF-PAGE -COUNT, SCAN-ADF-PAGE-COUNT, SCANNER-RETRIEVE-SCANLINE, SCANNER-MOTOR-CONTROL, COPIER-ADF-PAGE-COUNT, COPIER- PRINT-PAGE-COUNT, TOTAL-ENGINE-PAGE-COUNT, PRINT-ENGINE- JAM-COUNT, PRINT-ENGINE-MISPICK-COUNT, CLEAR-NVRAM" ::= { settings-system 9 } device-configure-generic-language-prompt OBJECT-TYPE SYNTAX INTEGER { eDisabled(1), eEnabled(2) } ACCESS read-write STATUS optional DESCRIPTION "This object is used to determine whether to prompt the user to enter the appropriate language. Additional information: This object is used to determine whether to prompt the user to enter the appropriate language at boot." ::= { device-configure 10 } device-configure-generic-country-prompt OBJECT-TYPE SYNTAX INTEGER { eDisabled(1), eEnabled(2) } ACCESS read-write STATUS optional DESCRIPTION " This object is used to determine whether to prompt the user to enter the appropriate country at boot. Additional information: This object is used to determine whether to prompt the user to enter the appropriate country at boot." ::= { device-configure 11 } on-off-line OBJECT-TYPE SYNTAX INTEGER { eOnline(1), eOffline(2) } ACCESS read-only STATUS optional DESCRIPTION "To bring the PDL processing sub-system on or off line. If the device is a printer, then the printer does not process print job data when the printer is off line. PML communication persists. Additional information: The value of this object is eOnline whenever the printer is in the ready state. This object will return eOffline only when an alert is active. For example, the printer will go eOffline if the cover is open, if the toner cartridge is removed, or if the paper trays are all empty. It is not possible to change the state of the printer with this object. " ::= { status-system 5 } auto-continue OBJECT-TYPE SYNTAX INTEGER { eOff(1), eOn(2) } ACCESS read-write STATUS optional DESCRIPTION "Indicates if the device will automatically continue after encountering a continuable error. If AUTO-CONTINUE is set to eOn, the device will automatically generate continue event to acknowledge continuable errors. If AUTO-CONTINUE is set to eOff, then some other continue event will have to acknowledge the continuable error." ::= { status-system 7 } install-date OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..14)) ACCESS read-write STATUS optional DESCRIPTION "Identifies the date that the device was installed. The format of the string is 'YYYYMMDDHHmmZ'. Where: YYYY is the year. MM is the month (1-12). DD is the day (1-31). HH is the hour of the day (0-23). mm are the minutes (0-59). 'Z' designates Greenwich Mean Time; if 'Z' not specified, value is local time. Device POS must specify the conditions for setting this object. Additional information: Identifies the date that the device was installed. The format of the string is 'YYYYMMDDHHmmZ'. Where: YYYY is the year. MM is the month (1-12). DD is the day (1-31). HH is the hour of the day (0-23). mm are the minutes (0-59). 'Z' designates Greenwich Mean Time; if 'Z' not specified, value is local time. On Products without a real-time clock this object has the inital value of 'INVALID'. While in the invalid state the object may written to. Once the initial install date has been written a new intall date can not be written without resetting the object to 'INVALID'. The behavior on products with real-time clocks is different. The object is set to the initial real-time clock value, usually this is '199000300000'. Manufacturing sets the real-time clock to the correct date and sets the INSTALL-DATE to 'INVALID'. Then when the customer turns on the printer for the first time the install date is reset." ::= { status-system 8 } show-address OBJECT-TYPE SYNTAX INTEGER { eAuto(3), eOff(1) } ACCESS read-write STATUS optional DESCRIPTION "If this object is set to eAuto, and the device has an IP address, the IP address of the device will be shown with the READY message. If this object is set to eOff, the IP address will not be shown." ::= { display-status 3 } job-input-auto-continue-timeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The number of seconds the device waits after a job related continuable error occurs before automatically continuing. An example job related continuable error is the job requesting a media size that is not available. After the timeout expires, the device will continue processing the job as if a continue event occurred, such as the front panel continue key being pressed. If the value is -1, the device does not automatically continue after a job related continuable error occurs. If the value is 0, the device immediately continues. If the value is greater than 0, the value represents the timeout value in seconds." ::= { status-system 35 } job-input-auto-continue-mode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the device behavior when the desired media is not currently available. cCancelJob - The device cancels the job. The device POS should explain what happens if this item is not the only item in the collection. cAutoMediaSizeOverride - The device is allowed to substitute a different size media. cAutoMediaNameOverride - The device is allowed to substitute a different media name. cUSMediaSizeOverride - The device is allowed to substitute US media sizes (letter, etc.) for ISO media sizes (A4, etc.). cISOMediaSizeOverride - The device is allowed to substitute ISO media sizes (A4, etc.) for US media sizes (letter, etc.). " ::= { status-system 36 } control-panel-button-press OBJECT-TYPE SYNTAX INTEGER { eGoButton(1), eBackButton(13), eNumericButton0(16), eNumericButton1(17), eNumericButton2(18), eNumericButton3(19), eNumericButton4(20), eNumericButton5(21), eNumericButton6(22), eNumericButton7(23), eNumericButton8(24), eNumericButton9(25), eAsterickButton(30), ePoundButton(31), eCopyButton(36), eStartFaxButton(42), eBackButton(13) } ACCESS write-only STATUS optional DESCRIPTION "Writing this object simulates pressing a button on the control panel. Reading it will return the last key pressed either on the control panel or via PML. The device POS will specify which keys are supported. Additional information: Writing this object simulates pressing a button on the control panel." ::= { status-system 60 } clear-nvram OBJECT-TYPE SYNTAX INTEGER { eClearUnprotectedNVRAM(1), eClearProtectedNVRAM(2), eClearCompleteNVRAM(3) } ACCESS write-only STATUS optional DESCRIPTION "Writing this object causes the specified NVRAM init option to be performed. Depending on the option, some (or all) of the permanent storage area will be completely erased. This object is only writable wen the SERVICE-PASSWORD has been set correctly. NOTE: This considerably more destructive than setting the prtGeneralReset object to ePresetToFactoryDefaults since it destroys page counts, serial number, and other items not normally affected by ePresetToFactoryDefaults. eClearUnprotectedNVRAM - clears unprotected NVRAM eClearProtectedNVRAM - clears protected NVRAM eClearCompleteNVRAM - clears both protected nd unprotected NVRAM. Additional information: Writing this object causes the specified NVRAM init option to be performed. Depending on the option, some (or all) of the permanent storage area will be completely erased. This object is only writable when the SERVICE-PASSWORD has been set correctly. NOTE: This considerably more destructive than setting the prtGeneralReset object to ePresetToFactoryDefaults since it destroys page counts, serial number, and other items not normally affected by ePresetToFactoryDefaults. eClearUnprotectedNVRAM - clears unprotected NVRAM eClearProtectedNVRAM - clears protected NVRAM eClearCompleteNVRAM - clears both protected nd unprotected NVRAM." ::= { status-system 68 } model-number OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Identifies the device model number as listed in the HP corporate price list (e.g. C2121A for DeskJet 500C). The string is as specific as possible. Products should note in POS if the model number on the CPL changes but the device reports the previous model number. If the model number changes based on the installed options, the POS should indicate if only the base model number is returned, or if the device senses the installed options and returns the correct model number. If possible, encode the model number in a symbol set (like Roman-8) that matches the ASCII character set and limit the characters used to ASCII characters. Additional information: Identifies the device model number as listed in the HP corporate price list (e.g. C2121A for DeskJet 500C)." ::= { id 1 } model-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Identifies the device model name (e.g. ''DeskJet 1200C''). The string is as specific as possible. Capitalization and spacing should match family naming conventions. Products should note in POS if the model name on the HP corporate price list changes but the device reports the previous device name. If the model name changes based on the installed options, the POS should indicate if only the base model name is returned, or if the device senses the installed options and returns the correct model name. If possible, encode the model name in a symbol set (like Roman-8) that matches the ASCII character set and limit the characters used to ASCII characters. Additional information: The value of this object changes based on the installed options. Since the value of this object is frequently used in displaying a list of printers, it is kept relatively short in case systems have limited width for their display area." ::= { id 2 } serial-number OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..10)) ACCESS read-write STATUS optional DESCRIPTION "Identifies the serial number for the device. If the SERIAL-NUMBER object is set by the user, then setting the object does not need to be protected. If the SERIAL-NUMBER object is set at the factory, then the SERVICE-PASSWORD object must be set correctly before the SERIAL-NUMBER object is writable. If this is a writable object, the POS should indicate the maximum supported string length. If possible, encode the serial number in a symbol set (like Roman-8) that matches the ASCII character set and limit the characters used to ASCII characters. Additional information: This value is initially set to the default value of XXXXXXXXXX." ::= { id 3 } fw-rom-datecode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Identifies the base system firmware date code. The date code will be encoded in the yyyymmdd format. There may be several versions of the base system firmware. The date code associated with the version of the base system firmware that is being used is reported. There may be other date code objects for other specific modules such as fonts, localization modules, etc.; these other datecode objects are device specific." ::= { id 5 } device-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "User defined device name. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as much as possible and will return the .Additional information: The maximum supported string length is 32 characters. If the user entered string is too long, the device will store the first 32 characters and will return the status." ::= { id 10 } asset-number OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..8)) ACCESS read-write STATUS optional DESCRIPTION "User defined asset number. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as much as possible and will return the .Additional information: The maximum supported string length is 8 characters. If the user entered string is too long, the device will store the first 8 characters and will return the status." ::= { id 12 } simm1-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eRamRom(9) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in SIMM slot 1. eEmpty means the device did not detect any option installed in the interface slot. eUnknown means the device doesn't recognize the installed option. eUnSupported means the device recognizes the installed option, but does not support the option. eReadOnlyMemory means the installed option contains ROM Ics. eVolatileRandomAccessMemory means the installed option contains RAM ICs that loose data when the power is turned off. eNonVolatileRandomAccessMemory means that the installed option contains RAM ICs that do not loose data when the power is turned off. eFlashMemory means that the installed option contains a type of non-volatile RAM that needs to be erased before it can be written. eDiskDrive means the installed option contains a disk drive. eRamRom means the installed option contains both volatile random access memory and read only memory. eInputPHD means the installed option is an input paper handling device. eOutputPHD means the installed option is an output paper handling device. eIOCard means the installed option is an I/O card. Additional information: This object is used to describe DIMMs instead of SIMMs on the product. eRamRom is used to denote a combo dimm." ::= { simm1 4 } simm1-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of the SIMM installed in SIMM slot 1. The capacity is dependent on the type of option, as indicated by the SIMM1-TYPE object. This object has no meaning if the installed option type is eUnknown or eReadOnlyMemory. This object contains the size, in bytes, if the installed option type is eVolatileRandomAccessMemory, eNonVolatileRandomAccessMemory, eFlashMemory, or eDiskDrive. If the type of the installed option is eRamRom, this object contains the size, in bytes, of the random access memory. If the type of the installed option is eInputPHD, the capacity indicates the number of input trays supported by the installed option. If the type of the installed option is eOutputPHD, the capacity indicates the number of output bins supported by the installed option. If the type of the installed option is eIOCard, the capacity indicates the number of logical I/O ports supported by the I/O card. Additional information: Returns an indication of the capacity of the installed option in bytes. This object is not supported unless the SIMM1-TYPE type is eVolatileRandomAccessMemory or eRamRom. For eRamRom only the size of the Ram portion of the simm (dimm) is returned." ::= { simm1 5 } self-test OBJECT-TYPE SYNTAX INTEGER { eNotInASelfTest(1), eNonDestructiveSelfTest(4) } ACCESS read-write STATUS optional DESCRIPTION "Writing this object allows a device self test to be started. Reading this object provides an indication what self-test is currently executing, if any. Actual self-test operation is device specific. A self test may not be allowed at any arbitrary time. If the device supports the requested self test, but can not start the execution of the self test when requested, the device will respond with . If a non-destructive self test is being started, the device will generate a response before the self test is completed. RECOMMENDATION: If the device is ready (i.e. the NOT-READY-PRINTER object does not contain any items, except maybe being off-line) and is idle (i.e. the NOT-IDLE object does not contain any items), this request should always succeed. This provides a mechanism for driver writers to always determine if the action will succeed or not. Additional information: The eNonDestructiveSelfTest performs limited testing on the printer and its attached paper handling devices. After the self-test is complete a configuration page is printed. The recommended way to cause a configuration page to be printed is to use the PRINT-INTERNAL-PAGE object. A continuous self test cannot be started or terminated using this OID. When the printer is idle, setting this object to eNonDestructiveSelfTest results in a status of and a value of eNonDestructiveSelfTest being returned. If the printer is not idle (whether printing an external job, printing an internal page or running self test), a status of status will be returned with a value of eNotInASelfTest. When the printer is idle, setting this object to eNonDestructiveSelfTest causes the configuration page to be formatted and put in the printer's print queue. Attempting to set this object before the configuration page has completed being formatted and printed will cause status to be returned with a value of eNotInASelfTest. After the configuration page is in the queue, a get on this object will return a value of eNotInASelfTest. Setting the value to eNotInASelfTest is not supported on the product. Once the test has started, it will finish printing. Likewise, if the PRINT-INTERNAL-PAGE object is set to a valid value and that page has not printed when this object is set to eNonDestructiveSelfTest, a status of status with a value of eNotInASelfTest will be returned until the internal page has printed." ::= { test 1 } print-internal-page OBJECT-TYPE SYNTAX INTEGER { eNotPrintingAnInternalPage(1), ePrintingAnUnknownInternalPage(2), eDeviceDemoPage1ConfigurationPage(3), eDeviceDemoPage2(4), eDeviceDemoPage7MenuMap(9), eDeviceUsagePage(10), eServicePage(13), eSuppliesPage(101), eDeviceCleaningPage(253), ePCLFontList1(350), ePCLXLFontList1(353), ePostScriptFontList1(450), eNetworkConfigPage(1200), ePrintQualityDiagnosticPage(1409), eColorUsageLog(1412) } ACCESS read-write STATUS optional DESCRIPTION "Writing this object to a value other than eNotPrintingAnInternalPage causes the device to attempt to print an internally generated page. Reading this object provides an indication what internally generated page is currently being printed, if any. The actual page is device specific. Some devices may support continuously printing an internally generated page. Setting this object to eNotPrintingAnInternalPage terminates continuously printing internally generated pages. An internally generated page may not be allowed to be printed at any arbitrary time; under what conditions it will succeed or fail is device specific. If the device supports the requested page, but can not start printing the page when requested, the device will respond with . RECOMMENDATION: If the device is ready (i.e. the NOT-READY-PRINTER object does not contain any items, except maybe being off-line) and is idle (i.e. the NOT-IDLE object does not contain any items), this request should always succeed. This provides a mechanism for driver writers to always determine if the action will succeed or not. Additional information: eDeviceDemoPage2 is the printer demo page. ePCLFontList1 is the PCL typeface list, ePostScriptFontList1 is the PostScript font list, and eDeviceDemoPage1ConfigurationPage is the selftest page. The product does not support continuously printing a demo page. The printer will queue requests if it is currently busy. When this object is set to a valid value and the printer is idle, the status returned is and the value returned is ePrintingAnUnknownInternalPage. Setting this object to a valid value causes the desired page to be formatted and put in the printer's print queue. While the page is being formatted, and the printer remains in a testing state, a get on this object will return the value ePrintingAnUnknownInternalPage. The return value will be eNotPrintingAnInternal page if the printer is not in a testing state, and the internal page is done being formatted. The user will not be able to set eNotPrintingAnInternalPage or ePrintingAnUnknownInternalPage, and the return status will be with a return value of eNotPrintingAnInternalPage. ePostScriptFontList1 and ePCLFontList1 will not be valid values unless postscript and PCL, respectively, are installed in the printer. If postscript (PCL) is not installed and the user attempts to set ePostScriptFontList1 (ePCLFontList1), the return status will be with a return value of eNotPrintingAnInternalPage. Setting through DMCMD will cause a 15 second delay in printing." ::= { test 2 } cancel-job OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Cancels the print job whose ID matches the value written to the CANCEL-JOB object. The host first learns the job ID using the CURRENT-JOB-PARSING-ID command. If the printer has completely processed the job, the printer responds with . If the value of the CURRENT-JOB-PARSING-ID is smaller than the value written to the CANCEL-JOB object, then the printer responds with . When read, returns the value of the last job ID what was canceled, or -1 to indicate no job has been canceled. Additional information: Cancels the print job whose ID matches the value written to the CANCEL-JOB object. The host first learns the job ID using the CURRENT-JOB-PARSING-ID command. If the printer has completely processed the job, the printer responds with . If the value of the CURRENT-JOB-PARSING-ID is smaller than the value written to the CANCEL-JOB object, then the printer responds with . When read, returns the value of the last job ID what was canceled, or -1 to indicate no job has been canceled." ::= { settings-job 2 } job-info-change-id OBJECT-TYPE SYNTAX OCTET STRING (SIZE(16)) ACCESS read-only STATUS optional DESCRIPTION "Returns the current value of an object in the job-info sub-tree whose value has changed. Define the object identifier for the object whose value has changed as job-info.required-field.optional-field.job-id. job-info represents the OID prefix of all objects in the job-info sub-tree. Required-field represents the OID field value that follows the job-info prefix. Since some objects in the job-info sub-tree have two OID fields between the job-info prefix and the job-id, the optional-field represents the OID field between the required-field and the job-id field, if present. Using this definition, the format for the JOB-INFO-CHANGE-ID binary value can be described as follows: Bytes 0-3 : required-field Bytes 4-7 : optional-field, or all zeros if there is no optional field Bytes 8-11: Job ID. Bytes 12-n : The value of the object job-info. required-field.optional-field.job-id. All multi-byte values stored in Motorola (big-endian) format, where the most significant byte occurs first. Additional information: The product will use this object to report changes of the job-info-pages-printed and job-info-state objects. The required-field (bytes 0 through 3) will designate whether the change to be reported involves the pages printed (13) or job state (15). The optional-field (bytes 4 through 7) will always be zeroes. The value-field (bytes 12 through 15) will contain the new value for pages printed or job state cast to a 32-bit integer." ::= { settings-job 3 } current-job-parsing-id OBJECT-TYPE SYNTAX INTEGER(-1..32767) ACCESS read-only STATUS optional DESCRIPTION "Contains the printer assigned job identification for the job currently being processed by the processing PDL sub-system. The job ID is a monotonically increasing number. The job ID may be reset to zero at power-up and may roll over to zero after reaching some maximum value. Additional information: A value of -1 is returned when the printer is not parsing a job. When data for a new job is detected, this object is updated (the job may or may not turn out to be a Null Job). (A job is considered to be a 'null job' if it has no name or job attribute, causes no pages to be printed, and consumes MIN_JOB_SIZE (9) or fewer bytes.) See the Job Boundary ERS for details on what constitutes a job boundary. Some job-info- objects are created when the first data bytes are received. If the printer determines that the job is a Null Job, the job-info- objects related to the Null Job are deleted. The product retains the job-info- objects for the MAX_JOBS_IN_LIST (12) most recent jobs that are not Null Jobs. The first job received after power-up will have job ID 1, and the job ID will increment to 32767 before rolling to zero. To distinguish whether a power cycle or a rollover causes a reduction in the job ID value, the object prtGeneralConfigChanges can be watched and if it increments at the same time as the drop is observed in the value of CURRENT-JOB-PARSING-ID, then a power cycle is the most likely cause." ::= { job-being-parsed 1 } job-info-io-source OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Indicates which I/O source, the print job was received over. The value maps to port numbering scheme supported in the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree. Additional information: The product does not support the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree." ::= { job-info 11 } job-info-outbins-used OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Indicates which output bins this job has delivered printed pages to. The last OID field for this dynamic object contains the job ID. Additional information: The product has only 1 output bin. cOutbin1 is the top/face-down bin." ::= { job-info 20 } error1-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 1 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: This item contains the engine page count when the error occurred. If there is currently no error entry for this object, a '0' will be returned. If ERROR1-CODE object also returns '0', then an error has not yet been logged for this object See ERROR1-CODE for an explanation of the order used for storing errors." ::= { error1 1 } error1-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: Returns a device specific error code. If the error code returned is '0', then the printer has not yet logged an error for this object. When the maximum number of errors is reached (10 on the product), and a new error occurs, the error in ERROR1-CODE will be replaced by the one in ERROR2-CODE, and so on until the last error object will be given the value of the new error. The error category is returned in the upper 16 bits, either 79 (for service) or 0 (for support). The lower 16 bits encodes the specific error. If an error is not a 79 service error, the value of this object is the PJL USTATUS code. If it is a 79 service error, the lower 16 bits contain the PJL USTATUS code. The types of errors reported for the product are: 49 Service Error 50-67 Service Error 69 Service Error 70-72 Service Error 79 Service Errors Access Error Address Error ASIC fault Asserts Bad Beam Detect Bad E-Label Bad Fan Bad Fuser Bad Malfunction Bad MIO Bad Scanner Motor Data Communication Error Engine Communication Error Format Error Genunine HP Supply Installed Illegal Instruction Insufficient Memory Invalid Personality Laser Malfunction MIO Buffer Overflow MIO Connection Break Missing E-Label Non-HP Supply Detected NVRAM Error NVRAM Service Error Parallel Buffer Overflow Print Page Punt Priviledge Violation Trace Fault Unimplemented Line-a Opcode Unimplemented Line-f Opcode Uninitialized Interrupt" ::= { error1 2 } error2-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 2 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error2 1 } error2-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error2 2 } error3-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 3 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error3 1 } error3-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error3 2 } error4-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 4 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error4 1 } error4-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error4 2 } error5-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 5 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error5 1 } error5-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error5 2 } error6-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 6 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error6 1 } error6-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error6 2 } error7-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 7 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error7 1 } error7-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error7 2 } error8-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 8 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error8 1 } error8-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error8 2 } error9-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 9 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error9 1 } error9-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error9 2 } error10-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 10 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error10 1 } error10-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error10 2 } firmware-download-version OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "This object will return a string value representing the current revision of firmware that the printer is operating with. This is used to determine if code needs to be upgraded when an firmware bundle comes in, in an upgrade job. Additional information: This object will return a string value representing the current revision of firmware that the printer is operating with. This is used to determine if code needs to be upgraded when an firmware bundle comes in, in an upgrade job." ::= { firmware-download 7 } io-timeout OBJECT-TYPE SYNTAX INTEGER(5..7200) ACCESS read-write STATUS optional DESCRIPTION "The amount of time, in seconds, to wait for more print job data to be received before an I/O timeout occurs. The I/O channel being timed is the I/O channel that received the data associated with the current print job. If an I/O timeout occurs, the PDL processing sub-system assumes all the data associated with the current print job has been received, and processes the end of job in an PDL specific manner. The POS specifies the supported values. Additional information: If an I/O timeout occurs,the PDL processing sub-system will consider it an end of job condition only if there is data from another I/O subsystem waiting to be processed. The supported values are 5 to 7200 seconds. Setting to a value outside the supported range returns status." ::= { settings-io 1 } io-switch OBJECT-TYPE SYNTAX INTEGER { eYes(1) } ACCESS read-only STATUS optional DESCRIPTION "Indicates if the device will switch between I/O channels when a job boundary is encountered and print job data is available on another I/O channel." ::= { settings-io 2 } default-copies OBJECT-TYPE SYNTAX INTEGER(1..999) ACCESS read-write STATUS optional DESCRIPTION "Returns or changes default copies. Default copies is the default values used by the PDL to control the number of copies of each page in the print job that are printed. The print job can override this value. The list of supported values should be documented in the device POS. Additional information: The supported values are 1 through 999. Setting to an unsupported value causes the printer to substitute in a snap value and to return status. The snaps are as follows: <1 snaps to >999 snaps to 999" ::= { settings-pdl 4 } default-vertical-black-resolution OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the value of the default vertical black resolution. The units are dots per inch. Additional information: In the product, changing this OID also causes DEFAULT-HORIZONTAL-BLACK RESOLUTION to change. DEFAULT-HORIZONTAL-BLACK-RESOLUTION and DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the same. The supported values are 300, 600, and 1200. Setting to an unsupported value causes the printer to substitute in a snap value and to return status. The snap values are as follows: <450 will snap to 300 >=450 and <900 will snap to 600 >=900 will snap to 1200" ::= { settings-pdl 8 } default-horizontal-black-resolution OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the value of the default horizontal black resolution. The units are dots per inch. Additional information: In the product, changing this OID also causes DEFAULT-VERTICAL-BLACK RESOLUTION to change. DEFAULT-HORIZONTAL-BLACK-RESOLUTION and DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the same. The supported values are 300, 600 and 1200. Setting to an unsupported value causes the printer to substitute in a snap value and to return status. The snap values are as follows: <450 snaps to 300 >=450 and <900 snaps to 600 >=900 snaps to 1200" ::= { settings-pdl 9 } default-lines-per-page OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the default number of lines per page. The POS indicates the supported values. An unsupported value causes the printer to use the closest supported value, causing the printer to return the . Additional information: The supported values in the product are 5 to 128. Setting to an unsupported value causes the printer to substitute in a snap value and to return status. The snap values are as follows: <5 snaps to 5 >128 snaps to 128" ::= { settings-pdl 11 } default-vmi OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the default vertical motion index. The unit of measure for VMI is centipoints per line. The POS indicates the supported values. An unsupported value causes the printer to use the closest supported value, causing the printer to return . Additional information: Setting this object may cause DEFAULT-LINES-PER-PAGE to change." ::= { settings-pdl 12 } default-media-size OBJECT-TYPE SYNTAX INTEGER { eUSExecutive(1), eUSLetter(2), eUSLegal(3), eFoolscap(10), eISOandJISA6(24), eISOandJISA5(25), eISOandJISA4(26), ePRC16K195X270(34), eJISB6(44), eJISB5(45), eJapansePostcardSingle(71), eJapansePostcardDouble(72), eIndexCard5x8(75), ePhoto4x6(76), eMonarch(80), eNo10Envelope(83), eROC16K184X260(89), eInternationalDL(90), eInternationalC5(91), eInternationalB5(100), ePhoto10x15(118) } ACCESS read-write STATUS optional DESCRIPTION "This indicates the default media size. A write of an unsupported value causes an . Complete list of supported media sizes along with their dimensions are listed in the ''Media Size Table'' near the end of this document. (for a full list of media size enums see the end of this file) " ::= { settings-pdl 13 } cold-reset-media-size OBJECT-TYPE SYNTAX INTEGER { eUSLetter(2), eISOandJISA4(26) } ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the media size that is used as the DEFAULT-MEDIA-SIZE when a cold reset occurs." ::= { settings-pdl 19 } default-media-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the media name that is used until the media name is changed by a print job command. Additional information: This string must be one of the MEDIAn-NAME objects, except it cannot be set to ANY. The value of this object is saved across a power cycle." ::= { settings-pdl 22 } reprint OBJECT-TYPE SYNTAX INTEGER { eOff(1), eOn(2), eAuto(3) } ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the reprint (jam recovery) setting. If eOn, then the device will reprint pages jammed pages. If eOff, the device will not attempt to reprint jammed pages. If eAuto, a device dependent algorithm (which should be documented in the POS) will be used to determine if the page gets reprinted. This object controls all PDLs, unless a specific PDL supports its own reprint control mechanism. To date, only PostScript has a PDL reprint control mechanism. Additional information: Setting this object when the printer is not idle, may cause a status of to be returned, but the new value will not take effect until a job boundary is reached. If a get is done on object before the job boundary is reached, the value last set will be returned. When the value is set to eOff, pages will not be stored in the printer, and in the event of a paper jam, will have to be reprinted. When the value is set to eOn, pages will be stored until delivery, therefore, in the event of a paper jam, the page will be reprinted. When the value is set to eAuto, the printer will behave as though it is eOff when there is less than seven megabytes of memory installed in the printer. When additional memory is installed, to total at least seven megabytes of RAM, the setting of eAuto will behave as though it was set to eOn." ::= { settings-pdl 36 } wide-a4 OBJECT-TYPE SYNTAX INTEGER { eOff(1), eOn(2) } ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the wide A4 logical page size setting. If eOn, then the margins/printable area of A4 paper will be changed to allow 80 10-pitch characters to be printed on a single line. If eOff then the industry standard A4 logical page size is used." ::= { settings-pdl 37 } dark-courier OBJECT-TYPE SYNTAX INTEGER { eOff(1), eOn(2) } ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the dark Courier setting. If eOn, then the Courier font used will approximate the same darkness as the LaserJet III printer. If eOff, then the Courier font used will approximate the same darkness as the LaserJet 4 printer." ::= { settings-pdl 38 } default-bits-per-pixel OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Controls the number of levels used (per pixel) when printing grayscale or color images." ::= { settings-pdl 39 } pcl-total-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Total number of PCL pages printed by the device." ::= { pdl-pcl 5 } pcl-default-font-height OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the default PCL height. Height is an approximate measure of the body of the type in centipoints. A centipoint is 1/7200 inch. Height applies only to proportional fonts. Point size, in points, can be converted to font height, in centipoints, by multiplying the point size by 100. The POS indicates the supported values. An unsupported value causes the printer to use the closest supported value, causing the printer to return . ''Closest'' means the smallest absolute difference. Additional information: This object refers to the font point size with 400 representing the smallest settable font (4) and 99975 representing the largest settable font (999.75). The default of 1200 is a font point size of 12. Supported values range from 400 to 99975. Setting to an unsupported value causes the printer to substitute in a snap value and to return status. The snap values are as follows: <=400 snaps to 400 >=99975 snaps to 99975 Fonts are settable to the nearest quarter point size (i.e. 10, 10.25, 10.50, 10.75). Unsupported values in the range 401 to 99974 snap DOWN to the previous supported value (i.e 25293 snaps to 25275 or 75038 snaps to 75025)." ::= { pdl-pcl 13 } pcl-default-font-source OBJECT-TYPE SYNTAX INTEGER { eInternal(1), ePermanentSoft(2), eRomSimm1(10) } ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the value of the default font source variable in NVRAM." ::= { pdl-pcl 14 } pcl-default-font-number OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the value of the default font number variable in NVRAM. Writing an unsupported value causes the printer to generate an . Additional information: Valid numbers or 0 - 255, but only font numbers that are included in the PCL FONT LIST are selectable." ::= { pdl-pcl 15 } pcl-default-font-width OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the default PCL font width. Width is expressed as the width of a character in centipoints. A centipoint is 1/7200 inch. Width applies only to fixed space fonts. Pitch, in character per inch, can be converted to font width, in centipoints, by dividing 7200 by the pitch. The POS indicates the supported values. An unsupported value causes the printer to use the closest supported value, causing the printer to return . ''Closest'' means the smallest absolute difference. Additional information: Setting to an unsupported value causes the printer to substitue in a snap value (listed below) and return status. The snap values for pitch are as follow: <=44 snaps to 44 >=9999 snaps to 9999 Unsupported values in the range 44 - 9999 (.44 - 99.99) snap DOWN to the next supported value." ::= { pdl-pcl 16 } postscript-total-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Total number of PostScript pages printed by the device." ::= { pdl-postscript 5 } postscript-print-errors OBJECT-TYPE SYNTAX INTEGER { eOff(1), eOn(2) } ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the value of the print PostScript errors setting. If eOn, PostScript prints an error page showing the error encountered and the stack at the time of the error. Additional information: Returns or changes the value of the print PostScript errors setting. If eOn, PostScript prints an error page showing the error encountered and the stack at the time of the error." ::= { pdl-postscript 11 } pjl-password OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns PJL password, if the password is not set (zero). If the password is set, then attempting to retrieve the password causes an to occur and will return the ." ::= { pjl 1 } print-density OBJECT-TYPE SYNTAX INTEGER(1..5) ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the print density setting. Print density is the instantaneous amount of marking agent applied to the paper while printing. A value of zero has the lowest print density, yielding a lighter page. A value of 10 has the highest print density, yielding a darker page. Each POS should document what values in the 0 to 10 range are supported. Additional information: When this value is written, the page pipeline will be flushed (all pages being printed are completed, no new ones are started), the new density setting is set and printing resumes. The acutal change in print density may be gradual over several pages. The supported values are 1 through 5. Setting to an unsupported value causes the printer to substitue in a a snap value and to return status. The snap values are as follows: <1 snaps to 1 >5 snaps to 5." ::= { settings-prt-eng 5 } invalid-personality-reports-enabled OBJECT-TYPE SYNTAX INTEGER { eDisabled(1), eEnabled(2) } ACCESS read-write STATUS optional DESCRIPTION "Read or configure wether invalid personality reports are enabled or disabled for a product." ::= { settings-prt-eng 18 } fast-first-page-out OBJECT-TYPE SYNTAX INTEGER { eOff(1), eOn(2) } ACCESS read-write STATUS optional DESCRIPTION "Return or set the value of the fast first page out setting. Additional information: Return or set the value of the fast first page out setting." ::= { settings-prt-eng 19 } total-engine-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Total number of pages printed by the device. POS indicates if the total engine page count is kept in NVRAM, and the maximum supported value before the page count rolls over to zero. Additional information: This object is stored in NVRAM. The maximum value of this count is 1000000 before it rolls over to zero." ::= { status-prt-eng 5 } print-engine-jam-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Total number of pages jammed in the print engine's life time. The POS indicates if the total jam count is kept in NVRAM and the maximum supported value before the jam count rolls over to zero. Additional information: This object is stored in NVRAM. The maximum value of this count is 65000 before it rolls over to zero." ::= { status-prt-eng 34 } print-engine-mispick-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Total number of pages mispicked in the print engine's life time. The POS indicates if the total mispick count is kept in NVRAM and the maximum supported value before the mispick count rolls over to zero. Additional information: This object is stored in NVRAM. The maximum value of this count is 65000 before it rolls over to zero." ::= { status-prt-eng 35 } duplex-page-count OBJECT-TYPE SYNTAX INTEGER(0..1000000) ACCESS read-write STATUS optional DESCRIPTION "Total number of sheets of media that have been duplex printed. A sheet is counted if it travels through the duplex page path, regardless of whether or not marks are made on the page. The POS will indicate if the value is kept in NVRAM. Additional information: Total number of sheets of media that have been duplex printed. A sheet is counted if it travels through the duplex page path, regardless of whether or not marks are made on the page. This object is stored in NVRAM. The maximum value of this count is 1000000 before it rolls over to zero." ::= { status-prt-eng 22 } print-engine-revision OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Print engine revision string. Additional information: Print engine revision string." ::= { status-prt-eng 26 } mp-tray OBJECT-TYPE SYNTAX INTEGER { eManual(1), eCassette(2), eFirst(3) } ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the value of the multi-purpose (MP) tray configuration variable. The MP tray can be configured to operate as an additional input tray (eCassette), a manual feed slot (eManual), or in a manner compatible with the LaserJet III manual feed slot (eFirst). If configured for eFirst, if media is present in the MP tray, that media is used (assuming the size matches and the print job didn't specify another tray) until the MP tray is empty. Additional information: Returns or changes the value of the multi-purpose (MP) tray configuration variable. The MP tray can be configured to operate as an additional input tray (eCassette), a manual feed slot (eManual), or in a manner compatible with the LaserJet III manual feed slot (eFirst). If configured for eFirst, if media is present in the MP tray, that media is used (assuming the size matches and the print job didn't specify another tray) until the MP tray is empty." ::= { settings-intray 5 } tray-lock OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the list of locked input trays. The printer only pulls media from a locked input tray when the input tray is specifically requested by the print job. Additional information: Returns or changes the list of locked input trays. The printer only pulls media from a locked input tray when the input tray is specifically requested by the print job." ::= { settings-intray 6 } custom-paper-dim-unit OBJECT-TYPE SYNTAX INTEGER { eTenThousandthsOfInches(3), eMicrometers(4) } ACCESS read-write STATUS optional DESCRIPTION "The units of measure used to specify the width and height of the printer's custom paper. The unit of measure of eTenThousandthsOfInches is 0.0001 inches. Additional information: The only valid values for this object are eTenThousandthsOfInches (3), and eMicrometers (4). The data for this object is stored in NVRAM." ::= { settings-intray 7 } custom-paper-feed-dim OBJECT-TYPE SYNTAX INTEGER(50000..140000) ACCESS read-write STATUS optional DESCRIPTION "Sets the printer's custom paper dimension in the feed direction (direction parallel to the direction of paper feeding). The value for this object is specified in micrometers or tenthousandths of an inch, depending upon the value of CUSTOM-PAPER-DIM-UNIT. The valid range is engine-dependent and should be documented in the POS for each product. Additional information: The valid range is 50000 to 140000 if CUSTOM-PAPER_DIM_UNIT is eTenThousandthsOfInches or 127000 to 355600 if CUSTOM-PAPER-DIM-UNIT is ePmicrometers. Attempts to set this object outside the valid range will result in a return value of ERROR_INVALID_OR_UNSUPPORTED_VALUE." ::= { settings-intray 8 } custom-paper-xfeed-dim OBJECT-TYPE SYNTAX INTEGER(30000..85000) ACCESS read-write STATUS optional DESCRIPTION "Sets the printer's custom paper dimension in the cross-feed direction (direction ninety degrees relative to the direction of paper feeding). The value for this object is specified in micrometers or tenthousandths of an inch, depending upon the value of CUSTOM-PAPER-DIM-UNIT. The valid range is engine-dependent and should be documented in the POS for each product. Additional information: The valid range for the product is 30000 to 85000 if CUSTOM-PAPER-DIM-UNIT is eTenThousandthsOfInches or 76200 to 215900 if CUSTOM-PAPER-DIM-UNIT is ePmicrometers. Attempts to set this object outside the valid range will result in a return value of ." ::= { settings-intray 9 } tray1-media-size-loaded OBJECT-TYPE SYNTAX INTEGER { eUSExecutive(1), eUSLetter(2), eUSLegal(3), eFoolscap(10), eISOandJISA6(24), eISOandJISA5(25), eISOandJISA4(26), ePRC16K195X270(34), eJISB6(44), eJISB5(45), eJapansePostcardSingle(71), eJapansePostcardDouble(72), eIndexCard5x8(75), ePhoto4x6(76), eMonarch(80), eNo10Envelope(83), eROC16K184X260(89), eInternationalDL(90), eInternationalC5(91), eInternationalB5(100), ePhoto10x15(118) } ACCESS read-write STATUS optional DESCRIPTION "Returns the media size that is currently configuredconfigured in tray #1. This object can be set to indicate the media size currently loaded, if the printer supports input trays that can not sense the media size. Complete list of supported media sizes along with their dimensions are listed in the ''Media Size Table'' near the end of this document. Additional information: Returns the media size that is currently configured in tray #1." ::= { intray1 1 } tray1-fuser-temperature OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The fuser temperature to be used when printing media from Tray 1. The value zero is the default temperature. Values less than zero are progressively lower and values greater than zero are progressively higher. The range of values supported is device specific. Additional information: The fuser temperature to be used when printing media from Tray 1. The value zero is the default temperature. Values less than zero are progressively lower and values greater than zero are progressively higher. The range of values supported is device specific." ::= { intray1 13 } tray2-media-size-loaded OBJECT-TYPE SYNTAX INTEGER { eUSExecutive(1), eUSLetter(2), eUSLegal(3), eFoolscap(10), eISOandJISA6(24), eISOandJISA5(25), eISOandJISA4(26), ePRC16K195X270(34), eJISB6(44), eJISB5(45), eJapansePostcardSingle(71), eJapansePostcardDouble(72), eIndexCard5x8(75), ePhoto4x6(76), eMonarch(80), eNo10Envelope(83), eROC16K184X260(89), eInternationalDL(90), eInternationalC5(91), eInternationalB5(100), ePhoto10x15(118) } ACCESS read-write STATUS optional DESCRIPTION "Returns the media size that is currently configured in tray #2. Complete list of supported media sizes along with their dimensions are listed in the ''Media Size Table'' near the end of this document." ::= { intray2 1 } tray2-fuser-temperature OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The fuser temperature to be used when printing media from Tray 2. The value zero is the default temperature. Values less than zero are progressively lower and values greater than zero are progressively higher. The range of values supported is device specific. Additional information: The fuser temperature to be used when printing media from Tray 2. The value zero is the default temperature. Values less than zero are progressively lower and values greater than zero are progressively higher. The range of values supported is device specific." ::= { intray2 13 } tray3-media-size-loaded OBJECT-TYPE SYNTAX INTEGER { eUSExecutive(1), eUSLetter(2), eUSLegal(3), eFoolscap(10), eISOandJISA6(24), eISOandJISA5(25), eISOandJISA4(26), ePRC16K195X270(34), eJISB6(44), eJISB5(45), eJapansePostcardSingle(71), eJapansePostcardDouble(72), eIndexCard5x8(75), ePhoto4x6(76), eROC16K184X260(89), ePhoto10x15(118) } ACCESS read-write STATUS optional DESCRIPTION "Returns the media size that is currently configured in tray #3. Complete list of supported media sizes along with their dimensions are listed in the ''Media Size Table'' near the end of this document." ::= { intray3 1 } tray3-fuser-temperature OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The fuser temperature to be used when printing media from Tray 3. The value zero is the default temperature. Values less than zero are progressively lower and values greater than zero are progressively higher. The range of values supported is device specific. Additional information: The fuser temperature to be used when printing media from Tray 3. The value zero is the default temperature. Values less than zero are progressively lower and values greater than zero are progressively higher. The range of values supported is device specific." ::= { intray3 13 } default-ret OBJECT-TYPE SYNTAX INTEGER { eOff(1), eLight(2), eMedium(3), eDark(4) } ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the Resolution Enhancement Technology setting. Devices that only support eOff and eOn should map all other values to eOn and always return the same non-eOff value to indicate on. The list of supported values should be documented in the device POS." ::= { imaging 5 } default-print-quality OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the default print quality. A value of zero has the lowest print quality. A value of 100 has the highest print quality. Each POS should document what values in the 0 to 100 range are supported. Additional information: The product supports DEFAULT-PRINT-QUALITY in 300, 600, and 1200 dpi. In the product, the supported values are 0 and 100. A value of zero has the lowest print quality (ECONOMODE=ON), thus minimizes the amount of toner used to print a page. A value of 100 has the highest print quality (ECONOMODE=OFF), thus uses more toner to print a page. Setting to an unsupported value outside of the 0 to 100 range causes the printer to return status. Setting to an unsupported value inside of the 0 to 100 range causes the printer to substitute in a snap value (listed below) and to return status. The snap values are as follow: 0 to 50 snaps to 0 51 to 100 snaps to 100" ::= { imaging 7 } media-names-available OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "The value of this object controls which of the MEDIAx-NAME objects are supported. If a bit is set to zero, then attempting to get or set the corresponding MEDIAx-NAME objects will return . Additional information: Since this object is read-only, the corresponding MEDIAx objects will always be available. The DEFAULTS below represent which MediaNameX is available on this product of the total possible available defined in SYNTAX, so the collection is like a bitfield. Raptor does not support cMediaName32Available" ::= { settings-print-media 1 } media1-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..3)) ACCESS read-only STATUS optional DESCRIPTION "Media 1 name. Additional information: The symbol set for this string is Roman-8." ::= { media1 1 } media1-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: The engine processing characteristics that are to be applied to this media type. Currently, 'engine processing characteristics' denotes changes to fusing temperature and/or transfer roller voltage." ::= { media1 4 } media2-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..5)) ACCESS read-only STATUS optional DESCRIPTION "Media 2 name. Additional information: The symbol set for this string is Roman-8." ::= { media2 1 } media2-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media2 4 } media3-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Media 3 name. Additional information: The symbol set for this string is Roman-8." ::= { media3 1 } media3-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media3 4 } media4-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Media 4 name. Additional information: The symbol set for this string is Roman-8." ::= { media4 1 } media4-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media4 4 } media5-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Media 5 name. Additional information: The symbol set for this string is Roman-8." ::= { media5 1 } media5-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media5 4 } media6-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..5)) ACCESS read-only STATUS optional DESCRIPTION "Media 6 name. Additional information: The symbol set for this string is Roman-8." ::= { media6 1 } media6-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media6 4 } media7-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..10)) ACCESS read-only STATUS optional DESCRIPTION "Media 7 name. Additional information: The symbol set for this string is Roman-8." ::= { media7 1 } media7-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media7 4 } media8-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..10)) ACCESS read-only STATUS optional DESCRIPTION "Media 8 name. Additional information: The symbol set for this string is Roman-8." ::= { media8 1 } media8-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media8 4 } media9-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..12)) ACCESS read-only STATUS optional DESCRIPTION "Media 9 name. Additional information: The symbol set for this string is Roman-8." ::= { media9 1 } media9-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media9 4 } media10-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..10)) ACCESS read-only STATUS optional DESCRIPTION "Media 10 name. Additional information: The symbol set for this string is Roman-8." ::= { media10 1 } media10-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media10 4 } media11-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Media 11 name. Additional information: The symbol set for this string is Roman-8." ::= { media11 1 } media11-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media11 4 } media12-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Media 12 name. Additional information: The symbol set for this string is Roman-8." ::= { media12 1 } media12-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media12 4 } media13-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Media 13 name. Additional information: The symbol set for this string is Roman-8." ::= { media13 1 } media13-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media13 4 } media14-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..6)) ACCESS read-only STATUS optional DESCRIPTION "Media 14 name. Additional information: The symbol set for this string is Roman-8." ::= { media14 1 } media14-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media14 4 } media15-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..4)) ACCESS read-only STATUS optional DESCRIPTION "Media 15 name. Additional information: The symbol set for this string is Roman-8." ::= { media15 1 } media15-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media15 4 } media16-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..8)) ACCESS read-only STATUS optional DESCRIPTION "Media 16 name. Additional information: The symbol set for this string is Roman-8." ::= { media16 1 } media16-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media16 4 } media17-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..5)) ACCESS read-only STATUS optional DESCRIPTION "Media 17 name. Additional information: The symbol set for this string is Roman-8." ::= { media17 1 } media17-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media17 4 } media18-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Media 18 name. Additional information: The symbol set for this string is Roman-8." ::= { media18 1 } media18-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media18 4 } media19-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..10)) ACCESS read-only STATUS optional DESCRIPTION "Media 19 name. Additional information: The symbol set for this string is Roman-8." ::= { media19 1 } media19-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media19 4 } media20-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..5)) ACCESS read-only STATUS optional DESCRIPTION "Media 20 name. Additional information: The symbol set for this string is Roman-8." ::= { media20 1 } media20-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media20 4 } media21-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..5)) ACCESS read-only STATUS optional DESCRIPTION "Media 21 name. Additional information: The symbol set for this string is Roman-8." ::= { media21 1 } media21-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media21 4 } media22-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..5)) ACCESS read-only STATUS optional DESCRIPTION "Media 22 name. Additional information: The symbol set for this string is Roman-8." ::= { media22 1 } media22-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media22 4 } media23-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..5)) ACCESS read-only STATUS optional DESCRIPTION "Media 23 name. Additional information: The symbol set for this string is Roman-8." ::= { media23 1 } media23-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media23 4 } media24-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Media 24 name. Additional information: The symbol set for this string is Roman-8." ::= { media24 1 } media24-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media24 4 } engine-media-modes-supported1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "The list of engine media modes supported by the device. The modes are each separated by a comma character. An example string would be: 'Normal,Rough,Low,Vellum'." ::= { media-modes 1 } consumable-status-serial-number OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "This object is used to report the serial number for this consumable." ::= { consumable-status 3 } consumable-life-usage-units-remaining OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "This object reports the current estimate of the number of usage units that remain before this supply is depleted. An installed supply that cannot report such a number will return a value of -2. It is the reponsibility of the host application to query each supply in order to determine an overall device USAGE-UNITS-REMAINING number - the lowest value returned. The unit of measure for this life estimate is determined by reading the corresponding CONSUMABLE-LIFE-USAGE-UNITS object. Additional information: This object reports the approximate number of pages remaining before this supply reaches very low. An installed cartridge that cannot report such a number (because supply status is not available) will return a value of -2. If the supply life is above 80% then this object will return ErrorActionCanNotBePerformedNow (or genErr if queried through SNMP)." ::= { consumables-life 1 } consumable-life-low-threshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "This object is used to report and/or modify a threshold value indicating the point in the life of a consumable or supply at which a transition to a LOW state will occur." ::= { consumables-life 3 } consumable-test-password OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS optional DESCRIPTION "When set with the correct integer password value this object is used to enable certain device specific test capabilities. When set with any incorrect integer value, this object is used to disable any device specific features previously enabled by this object. This object will return a response of whenever an attempt is made to query the object rather than so as to hide the existence of this object from external host applications." ::= { consumables-test 1 } prtGeneralConfigChanges OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Counts configuration changes that change the capabilities of a printer, such as the addition/deletion of input/output bins, the addition/deletion of interpreters, or changes in media size. Such changes will often affect the capability of the printer to service certain types of print jobs. Management applications may cache infrequently changed configuration information about sub-units on the printer. This object should be incremented whenever the agent wishes such applications to invalidate that cache and re-download all of this configuration information, thereby signaling a change in the printer's configuration. For example, if an input tray that contained paper of different dimensions was added, this counter would be incremented. As an additional example, this counter would not be incremented when an input tray is removed or the level of an input device changes. Additional information: This is a 32 bit counter (unsigned). When it reaches its maximum value, it will roll to zero." ::= { prtGeneralEntry 1 } prtGeneralCurrentLocalization OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The value of the prtLocalizationIndex corresponding to the current language, country, and character set to be used for localized string values that are identified as being dependent on the value of this object. Note that this object does not apply to localized strings in the prtConsole group or to any object that is not explicitly identified as being localized according to prtGeneralCurrentLocalization." ::= { prtGeneralEntry 2 } prtGeneralReset OBJECT-TYPE SYNTAX INTEGER { ePnotResetting(3), ePpowerCycleReset(4), ePresetToNVRAM(5), ePresetToFactoryDefaults(6) } ACCESS read-write STATUS optional DESCRIPTION "Setting this value to `powerCycleReset', `resetToNVRAM', or `resetToFactoryDefaults' will result in the resetting of the printer. When read, this object will always have the value `notResetting(3)', and a SET of the value `notResetting' shall have no effect on the printer. Some of the defined values are optional. However, every implementation must support at least the values `notResetting' and 'resetToNVRAM'. Additional information: Setting this object to ePnotResetting causes the printer to not reset. Setting this object to ePpowerCycleReset causes this device to do a reset. Setting this object to 'resetToNVRAM' does NOT perform an NVRAM init on the product. It causes the device to perform its power on initialization routines. All I/O buffers are reset and tests normally run at power on time are executed. Setting the object to 'resetToFactoryDefaults, causes the device to perform its reset to factory defaults routines. Also, the device will perform a power cycle, which is required to set all variables to their factory defaults." ::= { prtGeneralEntry 3 } prtGeneralCurrentOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..26)) ACCESS read-write STATUS optional DESCRIPTION "The name of the person who is responsible for operating this printer. It is suggested that this string include information that would enable other humans to reach the operator, such as a phone number. As a convention to facilitate automatic notification of the operator by the agent or the network management station, the phone number, fax number or email address should be placed on a separate line starting with ASCII LF (hex 0x0A) and the ASCII text string (without the quotes): 'phone: ', 'fax: ', and 'email: ', respectively. Phone numbers may contain digits, whitespace and parentheses, which shall be ignored. Phone numbers may also include ASCII comma characters(hex 2C) that are used to indicate a two-second pause during the dialing sequence. If either the phone, fax, or email information is not available, then a line should not be included for this information. NOTE: For interoperability purposes, it is advisable to use email addresses formatted according to RFC 822 requirements. Additional information: The maximum supported string length is 26 characters. If the user entered string is too long, the device will store as much as possible and will return the status." ::= { prtGeneralEntry 4 } prtGeneralServicePerson OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..28)) ACCESS read-write STATUS optional DESCRIPTION "The name of the person responsible for servicing this printer. It is suggested that this string include information that would enable other humans to reach the service person, such as a phone number. As a convention to facilitate automatic notification of the service person by the agent or a network management station, the phone number, fax number or email address should be placed on a separate line starting with ASCII LF (hex 0x0A) and the ASCII text string (without the quotes): 'phone: ', 'fax: ', and 'email: ', respectively. Phone numbers may contain digits, whitespace and parentheses, which shall be ignored. Phone numbers can also include one or more ASCII comma characters(hex 2C) to indicate a two-second pause during the dialing sequence. If either the phone,fax, or email information is not available, then a line should not included for this information. NOTE: For interoperability purposes, it is advisable to use email addresses formatted according to RFC 822 requirements. Additional information: The maximum supported string length is 28 characters. If the user entered string is too long, the device will store as much as possible and will return the status." ::= { prtGeneralEntry 5 } prtInputDefaultIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The value of prtInputIndex corresponding to the default input sub-unit: that is, this object selects the default source of input media. This value shall be -1 if there is no default input subunit specified for the printer as a whole. In this case, the actual default input subunit may be specified by means outside the scope of this MIB, such as by each interpreter in a printer with multiple interpreters. Additional information: The default input tray is determined by the printer based on DEFAULT-MEDIA-SIZE, what trays are locked (if any), and whether or not Tray 2 is installed. This object always returns -1, unknown." ::= { prtGeneralEntry 6 } prtOutputDefaultIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The value of prtOutputIndex corresponding to the default output sub-unit; that is, this object selects the default output destination. This value shall be -1 if there is no default output subunit specified for the printer as a whole. In this case, the actual default output subunit may be specified by means outside the scope of this MIB, such as by each interpreter in a printer with multiple interpreters. Additional information: The product has only one output bin, a face-down bin located at the top of the printer." ::= { prtGeneralEntry 7 } prtMarkerDefaultIndex OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS optional DESCRIPTION "The value of prtMarkerIndex corresponding to the default marker sub-unit; that is, this object selects the default marker. Additional information: The product only has one marker subunit." ::= { prtGeneralEntry 8 } prtMediaPathDefaultIndex OBJECT-TYPE SYNTAX INTEGER(1..3) ACCESS read-only STATUS optional DESCRIPTION "The value of prtMediaPathIndex corresponding to the default media path; that is, the selection of the default media path. Additional information: The only valid value for this object is 1 (simplex)." ::= { prtGeneralEntry 9 } prtConsoleLocalization OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The value of the prtLocalizationIndex corresponding to the language, country, and character set to be used for the console. This localization applies both to the actual display on the console as well as the encoding of these console objects in management operations." ::= { prtGeneralEntry 10 } prtConsoleNumberOfDisplayLines OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS optional DESCRIPTION "The number of lines on the printer's physical display. This value is 0 if there are no lines on the physical display or if there is no physical display." ::= { prtGeneralEntry 11 } prtConsoleNumberOfDisplayChars OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS optional DESCRIPTION "The number of characters per line displayed on the physical display. This value is 0 if there are no lines on the physical display or if there is no physical display. Additional information: The device has a 16 character by 2 line display." ::= { prtGeneralEntry 12 } prtConsoleDisable OBJECT-TYPE SYNTAX INTEGER { ePoperatorConsoleEnabled(3) } ACCESS read-only STATUS optional DESCRIPTION "If the object prtConsoleDisable has value 'operatorConsoleDisabled' then input is not accepted from the operator console. If the object prtConsoleDisable has the value 'operatorConsoleEnabled' then input is accepted from the operator console. If the object prtConsoleDisable has the value 'operatorConsoleEnabledLevel1','operatorConsoleEnabledLevel2' or 'operatorConsoleEnabledLevel3' then limited input is accepted from the operator console; the limitations are product specific, however, the limitations are generally less restrictive for operatorConsoleEnabledLevel1 than for operatorConsoleEnabledLeve2, which is less restrictive than operatorConsoleEnabledLevel3. The value of the prtConsoleDisable object is a type-2 enumeration." ::= { prtGeneralEntry 13 } prtGeneralPrinterName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) ACCESS read-write STATUS optional DESCRIPTION "An administrator-specified name for this printer. Depending upon implementation of this printer, the value of this object may or may not be same as the value for the MIB-II 'SysName' object. Additional information: The maximum supported string length is 32 characters. Length of 32 was chosen so a phone number could be included with the name. If the user-entered string is too long, the device will store as much as possible and will return the status. The value of this object is saved over a power cycle." ::= { prtGeneralEntry 16 } prtGeneralSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..11)) ACCESS read-only STATUS optional DESCRIPTION "A recorded serial number for this device that indexes some type device catalog or inventory. This value is usually set by the device manufacturer but the MIB supports the option of writeability for this object for site-specific administration of device inventory or tracking." ::= { prtGeneralEntry 17 } prtAlertCriticalEvents OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "A running counter of the number of critical alert events that have been recorded in the alert table. The value of this object is RESET in the event of a power cycle operation (i.e., the value is not persistent. Additional information: This object is set to zero every time the printer is turned on." ::= { prtGeneralEntry 18 } prtAlertAllEvents OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "A running counter of the total number of alert event entries (critical and non-critical) that have been recorded in the alert table Additional information: This object is set to zero every time the printer is turned on. (It is not persistent through a power-cycle.)" ::= { prtGeneralEntry 19 } prtCoverDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) ACCESS read-only STATUS optional DESCRIPTION "The manufacturer provided cover sub-mechanism name in the localization specified by prtGeneralCurrentLocalization." ::= { prtCoverEntry 2 } prtCoverStatus OBJECT-TYPE SYNTAX INTEGER { ePdoorOpen(3), ePdoorClosed(4) } ACCESS read-only STATUS optional DESCRIPTION "The status of this cover sub-unit." ::= { prtCoverEntry 3 } prtLocalizationLanguage OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..2)) ACCESS read-only STATUS optional DESCRIPTION "A two character language code from ISO 639. Examples en, gb, ca, fr, de." ::= { prtLocalizationEntry 2 } prtLocalizationCountry OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..2)) ACCESS read-only STATUS optional DESCRIPTION "A two character country code from ISO 3166, a blank string (two space characters) shall indicate that the country is not defined. Examples: US, FR, DE, ..." ::= { prtLocalizationEntry 3 } prtLocalizationCharacterSet OBJECT-TYPE SYNTAX INTEGER { ePcsHPRoman8(2004), ePcsISOLatin2(5), ePcsISOLatinCyrillic(8), ePcsISOLatin5(12), ePcsISOLatinGreek(10), ePcsISOLatinHebrew(11), ePcsISOLatinArabic(9), ePcsUnicode(2000) } ACCESS read-only STATUS optional DESCRIPTION "The coded character set used for this localization." ::= { prtLocalizationEntry 4 } prtStorageRefIndex OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS optional DESCRIPTION "The value of the hrDeviceIndex of the printer device that this storageEntry is associated with." ::= { prtStorageRefEntry 2 } prtDeviceRefIndex OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS optional DESCRIPTION "The value of the hrDeviceIndex of the printer device that this deviceEntry is associated with." ::= { prtDeviceRefEntry 2 } prtInputType OBJECT-TYPE SYNTAX INTEGER { ePsheetFeedAutoRemovableTray(3), ePsheetFeedAutoNonRemovableTray(4) } ACCESS read-only STATUS optional DESCRIPTION "The type of technology (discriminated primarily according to feeder mechanism type) employed by the input sub-unit. Note, the Optional Input Class provides for a descriptor field to further qualify the other choice. Additional information: Tray 1 is the multi-purpose tray and is always present. It supports both sheets and envelopes. Its type is ePsheetFeedAutoNonRemovableTray. The tray 2 object does not exist when the tray is NOT installed." ::= { prtInputEntry 2 } prtInputDimUnit OBJECT-TYPE SYNTAX INTEGER { ePtenThousandthsOfInches(3), ePmicrometers(4) } ACCESS read-only STATUS optional DESCRIPTION "The unit of measurement for use calculating and relaying dimensional values for this input sub-unit. Additional information: Following is a table of paper sizes and dimensions for each paper size supported by the product: Size....................Inches(ten-thousandths)...Micrometers ----------------------------------------------------------------- eUSExecutive............72500 x 105000............184150 x 266700 eUSLetter...............85000 x 110000............215900 x 279400 eUSLegal................85000 x 140000............215900 x 355600 eFoolscap...............85000 x 130000............215900 x 330200 eROC16K.................77500 x 107500............196850 x 273050 eISOandJISA4............82677 x 116929............210000 x 297000 eISOandJISA5............58286 x 82677.............148000 x 210000 eJISB5..................71654 x 101181............182000 x 257000 eIOSB5..................69300 x 98400.............176000 x 250000 eJapanesePostcardSingle.39370 x 58267.............100000 x 148000 eJapanesePostcardDouble.58267 x 78740.............148000 x 200000 eMonarch................38750 x 75000.............98425 x 190500 eCommercial10...........41250 x 95000.............104775 x 241300 eInternationalDL........43307 x 86614.............110000 x 220000 eInternationalC5........63780 x 90157.............162000 x 229000 eInternationalB5........69291 x 98425.............176000 x 250000 eCustom.................30000 x 140000(max).......76000 x 355600(max)" ::= { prtInputEntry 3 } prtInputMediaDimFeedDirDeclared OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "This object provides the value of the declared dimension, in the feed direction, of the media that is (or, if empty, was or will be) in this input sub-unit. The feed direction is the direction in which the media is fed on this sub-unit. This dimension is measured in input sub-unit dimensional units (prtInputDimUnit). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests. Otherwise, the value may be changed. The value (-1) means other and specifically means that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown. Additional information: The default values assume the trays are configured for letter size paper. For tray 1 the value is the dimension for the media size currently declared. Valid values are 50000 to 140000 if prtInputDimUnit is ePtenThousandthsOfInches and 127000 to 355600 if prtInputDimUnit is ePmicrometers." ::= { prtInputEntry 4 } prtInputMediaDimXFeedDirDeclared OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "This object provides the value of the declared dimension, in the cross feed direction, of the media that is (or, if empty, was or will be) in this input sub-unit. The cross feed direction is ninety degrees relative to the feed direction associated with this sub-unit. This dimension is measured in input sub-unit dimensional units (prtInputDimUnit). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests. Otherwise, the value may be changed. The value (-1) means other and specifically means that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown. Additional information: The default values assume the trays are configured for letter size paper. For trays 1 & 2, the value is the dimension for the media size currently declared. Valid values are 30000 to 85000 if prtInputDimUnit is ePtenThousandthsOfInches and 76000 to 216000 if prtInputDimUnit is ePmicrometers. The minimum value for tray 2 is 72500 (tenthousandsinch) and 191000(micrometers)." ::= { prtInputEntry 5 } prtInputMediaDimFeedDirChosen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The printer will act as if media of the chosen dimension (in the feed direction) is present in this input source. Note that this value will be used even if the input tray is empty. Feed dimension measurements are taken relative to the feed direction associated with that sub-unit and are in input sub-unit dimensional units (MediaUnit). If the printer supports the declared dimension, the granted dimension is the same as the declared dimension. If not, the granted dimension is set to the closest dimension that the printer supports when the declared dimension is set. The value (-1) means other and specifically indicates that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown. Additional information: The default value assumes the trays are configured for letter size paper. The objects for the trays return the value of the media size for which the trays are currently configured because it cannot sense what size media they contain." ::= { prtInputEntry 6 } prtInputMediaDimXFeedDirChosen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The printer will act as if media of the chosen dimension (in the cross feed direction) is present in this input source. Note that this value will be used even if the input tray is empty. The cross feed direction is ninety degrees relative to the feed direction associated with this sub-unit. This dimension is measured in input sub-unit dimensional units (MediaUnit). If the printer supports the declared dimension, the granted dimension is the same as the declared dimension. If not, the granted dimension is set to the closest dimension that the printer supports when the declared dimension is set. The value (-1) means other and specifically indicates that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown. Additional information: The default value assumes the trays are configured for letter size paper. The object for the trays return the value of the media size for which the trays are currently configured because it cannot sense what size media it contains." ::= { prtInputEntry 7 } prtInputCapacityUnit OBJECT-TYPE SYNTAX INTEGER { ePsheets(8) } ACCESS read-only STATUS optional DESCRIPTION "The unit of measurement for use in calculating and relaying capacity values for this input sub-unit. Additional information: A sheet is a single piece of 20 pound paper. " ::= { prtInputEntry 8 } prtInputMaxCapacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The maximum capacity of the input sub-unit in input sub-unit capacity units (PrtCapacityUnitTC). There is no convention associated with the media itself so this value reflects claimed capacity. If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. Additional information: This is specified assuming 20 pound paper for the paper trays." ::= { prtInputEntry 9 } prtInputCurrentLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The current capacity of the input sub-unit in input sub-unit capacity units (PrtCapacityUnitTC). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Contol Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. The value (-3) means that the printer knows that at least one unit remains. Additional information: The product can only detect empty/not empty in its trays. It returns -3 for not empty and -2 (unknown) for any other condition (e.g. tray is empty or tray is removed)." ::= { prtInputEntry 10 } prtInputStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The current status of this input sub-unit. Additional information: The default value assumes that media is loaded in the tray. When there is not media loaded in the tray it returns 9 instead of 0 (the default). Default - 0 (Available and Idle) paper motion - 6 (Available and Busy) paper out in this tray - 9 (Non-Critical Alert(8) + Unavailable and OnRequest(1)) paper mount in this tray - 48 (Critical Alert (16) + OffLine (32)) manual feed prompt (PaperMount) - 48 (Critical Alert (16) + OffLine (32))" ::= { prtInputEntry 11 } prtInputMediaName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS optional DESCRIPTION "A description of the media contained in this input sub-unit; This description is intended for display to a human operator. This description is not processed by the printer. It is used to provide information not expressible in terms of the other media attributes (e.g. prtInputMediaDimFeedDirChosen, prtInputMediaDimXFeedDirChosen, prtInputMediaWeight, prtInputMediaType). An example would be `legal tender bond paper'. Additional information: The product supports the concept of named media types. The values for this object will always match one of the MEDIAn-NAME objects." ::= { prtInputEntry 12 } prtInputName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-only STATUS optional DESCRIPTION "The name assigned to this input sub-unit." ::= { prtInputEntry 13 } prtInputVendorName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-only STATUS optional DESCRIPTION "The vendor name of this input sub-unit." ::= { prtInputEntry 14 } prtInputModel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-only STATUS optional DESCRIPTION "The model name of this input sub-unit. Additional information: The product does not specify model names for the input trays." ::= { prtInputEntry 15 } prtInputVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-only STATUS optional DESCRIPTION "The version of this input sub-unit. Additional information: The product does not specify version numbers for the input trays." ::= { prtInputEntry 16 } prtInputSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-only STATUS optional DESCRIPTION "The serial number assigned to this input sub-unit. Additional information: The product does not specify serial numbers for the input trays." ::= { prtInputEntry 17 } prtInputDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) ACCESS read-only STATUS optional DESCRIPTION "A free-form text description of this input sub-unit in the localization specified by prtGeneralCurrentLocalization." ::= { prtInputEntry 18 } prtInputSecurity OBJECT-TYPE SYNTAX INTEGER { ePother(1), ePon(3), ePoff(4), ePnotPresent(5) } ACCESS read-only STATUS optional DESCRIPTION "Indicates if this input sub-unit has some security associated with it. Additional information: No security mechanism provided." ::= { prtInputEntry 19 } prtOutputType OBJECT-TYPE SYNTAX INTEGER { ePother(1), ePunknown(2), ePremovableBin(3), ePunRemovableBin(4), ePcontinuousRollDevice(5), ePmailBox(6), ePcontinousFanFold(7) } ACCESS read-only STATUS optional DESCRIPTION "The type of technology supported by this output sub-unit. Additional information: The product has only one output bin, a face-down bin located at the top of the printer." ::= { prtOutputEntry 2 } prtOutputCapacityUnit OBJECT-TYPE SYNTAX INTEGER { ePtenThousandthsOfInches(3), ePmicrometers(4), ePsheets(8), ePfeet(16), ePmeters(17) } ACCESS read-only STATUS optional DESCRIPTION "The unit of measurement for use in calculating and relaying capacity values for this output sub-unit. Additional information: A sheet is a single piece of 20 pound paper." ::= { prtOutputEntry 3 } prtOutputMaxCapacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The maximum capacity of this output sub-unit in output sub-unit capacity units (PrtCapacityUnitTC). There is no convention associated with the media itself so this value essentially reflects claimed capacity. If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. Additional information: Note: The product cannot sense how much is in the output bin. The output bin can hold 125 sheets." ::= { prtOutputEntry 4 } prtOutputRemainingCapacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The remaining capacity of the possible output sub-unit capacity in output sub-unit capacity units (PrtCapacityUnitTC) of this output sub-unit. If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be modified by management requests; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. The value (-3) means that the printer knows that there remains capacity for at least one unit. Additional information: The product does not have any sensing on the output bin, so it will always report unknown (-2). Note that for the products, this object is read-only because any values written by a Remote Control Panel or a Management Application would be unreliable." ::= { prtOutputEntry 5 } prtOutputStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The current status of this output sub-unit. Additional information: The product cannot sense the output tray so this object will always return 5 (Unknown Status)." ::= { prtOutputEntry 6 } prtMarkerMarkTech OBJECT-TYPE SYNTAX INTEGER { ePelectrophotographicLaser(4) } ACCESS read-only STATUS optional DESCRIPTION "The type of marking technology used for this marking sub-unit." ::= { prtMarkerEntry 2 } prtMarkerCounterUnit OBJECT-TYPE SYNTAX INTEGER { ePimpressions(7) } ACCESS read-only STATUS optional DESCRIPTION "The unit that will be used by the printer when reporting counter values for this marking sub-unit. The time units of measure are provided for a device like a strip recorder that does not or cannot track the physical dimensions of the media and does not use characters, lines or sheets. Additional information: Since the product keeps track of pages printed, the counter unit will be defined as ePimpressions which would be like saying pages printed. (The term 'impressions' is used instead of 'pages' to avoid confusion between 'sheets' and 'pages' on a duplexing printer.)" ::= { prtMarkerEntry 3 } prtMarkerLifeCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The count of the number of units of measure counted during the life of printer using units of measure as specified by prtMarkerCounterUnit. Additional information: In the product, the total engine page count is kept in NVRAM, however the NVRAM value is only updated every 10 impressions. NOTE: The value returned by this OID will be incremented every page but if power is lost between NVRAM updates, up to 9 impressions of the page count may be lost. The counter will be reset to zero after 999999 pages. The page count is incremented when a sheet of media is pulled from an input tray." ::= { prtMarkerEntry 4 } prtMarkerPowerOnCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The count of the number of units of measure counted since the equipment was most recently powered on using units of measure as specified by prtMarkerCounterUnit." ::= { prtMarkerEntry 5 } prtMarkerProcessColorants OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS optional DESCRIPTION "The number of process colors supported by this marker. A process color of 1 implies monochrome. The value of this object and prtMarkerSpotColorants cannot both be 0. The value of prtMarkerProcessColorants must be 0 or greater." ::= { prtMarkerEntry 6 } prtMarkerSpotColorants OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS optional DESCRIPTION "The number of spot colors supported by this marker. The value of this object and prtMarkerProcessColorants cannot both be 0. Must be 0 or greater." ::= { prtMarkerEntry 7 } prtMarkerAddressabilityUnit OBJECT-TYPE SYNTAX INTEGER { ePtenThousandthsOfInches(3) } ACCESS read-only STATUS optional DESCRIPTION "The unit of measure of distances, as applied to the marker's resolution. Additional information: This will always be ePtenThousandthsOfInches, no matter what COLD-RESET-MEDIA-SIZE is because we are talking about resolution and toner addressability, which is always dpi." ::= { prtMarkerEntry 8 } prtMarkerAddressabilityFeedDir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The maximum number of addressable marking positions in the feed direction per 10000 units of measure specified by prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'. Additional information: Use this object to specify resolution. The product supports 600 dots per inch." ::= { prtMarkerEntry 9 } prtMarkerAddressabilityXFeedDir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The maximum number of addressable marking positions in the cross feed direction in 10000 units of measure specified by prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'. Additional information: Use this object to specify resolution. The product supports 600 dots per inch." ::= { prtMarkerEntry 10 } prtMarkerNorthMargin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The margin, in units identified by prtMarkerAddressabilityUnit, from the leading edge of the medium as the medium flows through the marking engine with the side to be imaged facing the observer. The leading edge is the North edge and the other edges are defined by the normal compass layout of directions with the compass facing the observer. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown." ::= { prtMarkerEntry 11 } prtMarkerSouthMargin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The margin from the South edge (see prtMarkerNorthMargin) of the medium in units identified by prtMarkerAddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown." ::= { prtMarkerEntry 12 } prtMarkerWestMargin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The margin from the West edge (see prtMarkerNorthMargin) of the medium in units identified by prtMarkerAddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown." ::= { prtMarkerEntry 13 } prtMarkerEastMargin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The margin from the East edge (see prtMarkerNorthMargin) of the medium in units identified by prtMarkerAddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown." ::= { prtMarkerEntry 14 } prtMarkerStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The current status of this marker sub-unit. Additional information: The default value assumes the printer is idle and has no malfunctions. Default - 0 (Available and Idle) no toner cartridge - 51 (UnAvailable because Broken (3) + Critical Alert (16) + OffLine (32))" ::= { prtMarkerEntry 15 } prtMarkerSuppliesMarkerIndex OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS optional DESCRIPTION "The value of prtMarkerIndex corresponding to the marking sub-unit with which this marker supply sub-unit is associated." ::= { prtMarkerSuppliesEntry 2 } prtMarkerSuppliesColorantIndex OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS optional DESCRIPTION "The value of prtMarkerColorantIndex corresponding to the colorant with which this marker supply sub-unit is associated. This value shall be 0 if there is no colorant table." ::= { prtMarkerSuppliesEntry 3 } prtMarkerSuppliesClass OBJECT-TYPE SYNTAX INTEGER { ePother(1), ePsupplyThatIsConsumed(3), ePreceptacleThatIsFilled(4) } ACCESS read-only STATUS optional DESCRIPTION "Indicates whether this supply entity represents a supply that is consumed or a receptacle that is filled." ::= { prtMarkerSuppliesEntry 4 } prtMarkerSuppliesType OBJECT-TYPE SYNTAX INTEGER { ePtoner(3), ePtransferUnit(20), ePtonerCartridge(21), ePfuser(15), ePdeveloper(10), ePfuserCleaingPad(19), ePopc(9) } ACCESS read-only STATUS optional DESCRIPTION "The type of this supply." ::= { prtMarkerSuppliesEntry 5 } prtMarkerSuppliesDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) ACCESS read-only STATUS optional DESCRIPTION "The description of this supply container/receptacle in the localization specified by prtGeneralCurrentLocalization. Additional information: " ::= { prtMarkerSuppliesEntry 6 } prtMarkerSuppliesSupplyUnit OBJECT-TYPE SYNTAX INTEGER { ePtenThousandthsOfInches(3), ePmicrometers(4), ePimpressions(7), ePsheets(8), ePthousandthsOfOunces(12), ePhours(11), ePtenthsOfGrams(13), ePhundrethsOfFluidOunces(14), ePtenthsOfMilliliters(15), ePfeet(16), ePmeters(17), ePpercent(19) } ACCESS read-only STATUS optional DESCRIPTION "Unit of measure of this marker supply container/receptacle." ::= { prtMarkerSuppliesEntry 7 } prtMarkerSuppliesMaxCapacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The maximum capacity of this supply container/receptacle expressed in prtMarkerSuppliesSupplyUnit. If this supply container/receptacle can reliably sense this value, the value is reported by the printer and is read-only; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. Additional information: This object reports the maximum capacity for the supply against which the level is reported." ::= { prtMarkerSuppliesEntry 8 } prtMarkerSuppliesLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The current level if this supply is a container; the remaining space if this supply is a receptacle. If this supply container/receptacle can reliably sense this value, the value is reported by the printer and is read-only; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. A value of (-3) means that the printer knows that there is some supply/remaining space, respectively. Additional information: Print Cartridges measure life based on the three components: toner, developer and drum. These Print Cartridge object (1) report the lowest of these three factors. Print Cartridges that are not installed will return a value of 100." ::= { prtMarkerSuppliesEntry 9 } prtMarkerColorantMarkerIndex OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS optional DESCRIPTION "The value of prtMarkerIndex corresponding to the marker sub-unit with which this colorant entry is associated." ::= { prtMarkerColorantEntry 2 } prtMarkerColorantRole OBJECT-TYPE SYNTAX INTEGER { ePother(1), ePprocess(3), ePspot(4) } ACCESS read-only STATUS optional DESCRIPTION "The role played by this colorant." ::= { prtMarkerColorantEntry 3 } prtMarkerColorantValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) ACCESS read-only STATUS optional DESCRIPTION "The name of the color of this colorant using standardized string names from ISO 10175 (DPA) and ISO 10180 (SPDL) which are: other unknown white red green blue cyan magenta yellow black Implementors may add additional string values. The naming conventions in ISO 9070 are recommended in order to avoid potential name clashes. Additional information: " ::= { prtMarkerColorantEntry 4 } prtMarkerColorantTonality OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The distinct levels of tonality realizable by a marking sub-unit when using this colorant. This value does not include the number of levels of tonal difference that an interpreter can obtain by techniques such as half toning. This value must be at least 2." ::= { prtMarkerColorantEntry 5 } prtMediaPathMaxSpeedPrintUnit OBJECT-TYPE SYNTAX INTEGER { ePimpressionsPerHour(7) } ACCESS read-only STATUS optional DESCRIPTION "The unit of measure used in specifying the speed of all media paths in the printer. Additional information: ePimpressionsPerHour is the value that will always be returned for this object. (Print Speed is measured in pages-per-minute (impressions per minute), so ePimpressionsPerHour is a natural extension.)" ::= { prtMediaPathEntry 2 } prtMediaPathMediaSizeUnit OBJECT-TYPE SYNTAX INTEGER { ePtenThousandthsOfInches(3), ePmicrometers(4) } ACCESS read-only STATUS optional DESCRIPTION "The units of measure of media size for use in calculating and relaying dimensional values for all media paths in the printer." ::= { prtMediaPathEntry 3 } prtMediaPathMaxSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The maximum printing speed of this media path expressed in prtMediaPathMaxSpeedUnit's. A value of (-1) implies 'other'. Additional information: The page size for this performance is 8.5 x 11. For the product, this value is (12ppm * 60)." ::= { prtMediaPathEntry 4 } prtMediaPathMaxMediaFeedDir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The maximum physical media size in the feed direction of this media path expressed in units of measure specified by PrtMediaPathMediaSizeUnit. A value of (-1) implies 'unlimited', a value of (-2) implies 'unknown'. Additional information: The value returned by this object depends on the value of prtMediaPathMediaSizeUnit. It is 140000 if prtInputDimUnit is ePtenThousandthsOfInches or 355600 if prtInputDimUnit is ePmicrometers. (140000 is the value arrived at because legal paper is the longest allowable on the product.)" ::= { prtMediaPathEntry 5 } prtMediaPathMaxMediaXFeedDir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The maximum physical media size across the feed direction of this media path expressed in units of measure specified by prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'. Additional information: The value returned by this object depends on the value of prtMediaPathMediaSizeUnit. It is 85000 if prtInputDimUnit is ePtenThousandthsOfInches or 216000 if prtInputDimUnit is ePmicrometers." ::= { prtMediaPathEntry 6 } prtMediaPathMinMediaFeedDir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The minimum physical media size in the feed direction of this media path expressed in units of measure specified by prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'. Additional information: The value returned by this object depends on the value of prtMediaPathMediaSizeUnit. It is 50000 if prtInputDimUnit is ePtenThousandthsOfInches or 127000 if prtInputDimUnit is ePmicrometers." ::= { prtMediaPathEntry 7 } prtMediaPathMinMediaXFeedDir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The minimum physical media size across the feed direction of this media path expressed in units of measure specified by prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'. Additional information: The value returned by this object depends on the value of prtMediaPathMediaSizeUnit. It is 30000 if prtInputDimUnit is ePtenThousandthsOfInches or 76200 if prtInputDimUnit is ePmicrometers. This size corresponds to a Monarch envelope. " ::= { prtMediaPathEntry 8 } prtMediaPathType OBJECT-TYPE SYNTAX INTEGER { ePsimplex(5) } ACCESS read-only STATUS optional DESCRIPTION "The type of the media path for this media path. Additional information: This object describes how many paths there are through the engine disregarding the paper source (tray 1, 2, or 3)." ::= { prtMediaPathEntry 9 } prtMediaPathDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) ACCESS read-only STATUS optional DESCRIPTION "The manufacturer-provided description of this media path in the localization specified by prtGeneralCurrentLocalization." ::= { prtMediaPathEntry 10 } prtMediaPathStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The current status of this media path. Additional information: The default values assume the printer is idle. Default - 0 (Available and Idle) paper motion - 6 (Available and Busy) paper out in all trays - 9 (Non-Critical Alert(8) + Unavailable and OnRequest(1)) paper mount (any tray) - 0 (Available and Idle) manual feed prompt (PaperMount) - 48 (Critical Alert (16) + OffLine (32))" ::= { prtMediaPathEntry 11 } prtInterpreterLangFamily OBJECT-TYPE SYNTAX INTEGER { ePother(1), ePlangPCL(3), ePlangPJL(5), ePlangPS(6), ePlangAutomatic(37), ePlangPCLXL(47) } ACCESS read-only STATUS optional DESCRIPTION "The family name of a Page Description Language (PDL) or control language which this interpreter in the printer can interpret or emulate. Additional information: ePlangAutomatic refers to the 'super-language' made available by implicit language switching." ::= { prtInterpreterEntry 2 } prtInterpreterLangLevel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..31)) ACCESS read-only STATUS optional DESCRIPTION "The level of the language which this interpreter is interpreting or emulating. This might contain a value like '5e' for an interpreter which is emulating level 5e of the PCL language. It might contain '2' for an interpreter which is emulating level 2 of the PostScript language. Similarly it might contain '2' for an interpreter which is emulating level 2 of the HPGL language." ::= { prtInterpreterEntry 3 } prtInterpreterLangVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..31)) ACCESS read-only STATUS optional DESCRIPTION "The date code or version of the language which this interpreter is interpreting or emulating. Additional information: These values are derived from the dateCode field of the personality entities. (ePlangautomatic uses the PJL dateCode.) For PostScript, this is more detailed revision information." ::= { prtInterpreterEntry 4 } prtInterpreterDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) ACCESS read-only STATUS optional DESCRIPTION "A string to identify this interpreter in the localization specified by prtGeneralCurrentLocalization as opposed to the language which is being interpreted. It is anticipated that this string will allow manufacturers to unambiguously identify their interpreters. Additional information: None of these strings are localized." ::= { prtInterpreterEntry 5 } prtInterpreterVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..31)) ACCESS read-only STATUS optional DESCRIPTION "The date code, version number, or other product specific information tied to this interpreter. This value is associated with the interpreter, rather than with the version of the language which is being interpreted or emulated. Additional information: Same as prtInterpreterLangVersion." ::= { prtInterpreterEntry 6 } prtInterpreterDefaultOrientation OBJECT-TYPE SYNTAX INTEGER { ePportrait(3), ePlandscape(4) } ACCESS read-write STATUS optional DESCRIPTION "The current orientation default for this interpreter. This value may be overridden for a particular job (e.g., by a command in the input data stream). Additional information: Interpreters 1 and 2 ignore the value of this object. The values for PCL and PostScript are either ePportrait or ePlandscape; attempting to set them to a different value will cause to be returned. Setting this object for one interpreter will change it for all installed interpreters." ::= { prtInterpreterEntry 7 } prtInterpreterFeedAddressability OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The maximum interpreter addressability in the feed direction in 10000 prtMarkerAddressabilityUnits (see prtMarkerAddressabilityFeedDir ) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter." ::= { prtInterpreterEntry 8 } prtInterpreterXFeedAddressability OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The maximum interpreter addressability in the cross feed direction in 10000 prtMarkerAddressabilityUnits (see prtMarkerAddressabilityXFeedDir) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter." ::= { prtInterpreterEntry 9 } prtInterpreterDefaultCharSetIn OBJECT-TYPE SYNTAX INTEGER { ePother(1), ePcsASCII(3), ePcsISOLatin1(4), ePcsISOLatin2(5), ePcsISOLatin5(12), ePcsISOLatin6(13), ePcsISOLatin9(2090), ePcsISO4UnitedKingdom(20), ePcsISO11SwedishforNames(21), ePcsISO15Italian(22), ePcsISO17Spanish(23), ePcsISO21German(24), ePcsISO60DanishNorwegian(25), ePcsISO69French(26), ePcsUnicodeIBM2039(1004), ePcsWindows30Latin1(2000), ePcsWindows31Latin1(2001), ePcsWindows31Latin2(2002), ePcsWindows31Latin5(2003), ePcsHPRoman8(2004), ePcsAdobeStandardEncoding(2005), ePcsPC850Multilingual(2009), ePcsPC858Multilingual(2089), ePcsPCp852(2010), ePcsPC8CodePage437(2011), ePcsPC8DNDanishNorwegian(2012), ePcsHPPC8Turkish(2014), ePcsHPLegal(2017), ePcsHPDeskTop(2021), ePcsMacintosh(2027), ePcsPC77Baltic(2087), ePcsWindows1257Baltic(2257) } ACCESS read-write STATUS optional DESCRIPTION "The default coded character set for input octets encountered outside a context in which the Page Description Language established the interpretation of the octets. (Input octets are presented to the interpreter through a path defined in the channel group.) This value shall be (2) if there is no default. Additional information: ePcsAdobeStandardEncoding is the same as PSText(10J). The object corresponding to PCL has read-write access; all others are read-only. Note: To determine which languages correspond to which subarrays refer to the object prtInterpreterLangFamily. The above list corresponds to the following symbol sets as they appear on the Control Panel: ePother( 1) - used if designated coded char. set not in list ePcsASCII( 3) - ISO-6 ePcsISOLatin1( 4) - ISO L1 ePcsISOLatin2( 5) - IS L2 ePcsISOLatin5( 12) - ISO L5 ePcsISOLatin6( 13) - ISO L6 ePcsISOLatin9( 2090) - ISO L9 ePcsISO4UnitedKingdom( 20) - ISO-4 ePcsISO11SwedishforNames( 21) - ISO-11 ePcsISO15Italian( 22) - ISO-15 ePcsISO17Spanish( 23) - ISO-17 ePcsISO21German( 24) - ISO-21 ePcsISO60DanishNorwegian( 25) - ISO-60 ePcsISO69French( 26) - ISO-69 ePcsUnicodeIBM2039(1004) - PC-1004 ePcsWindows30Latin1( 2000) - WIN 3.0 ePcsWindows31Latin1( 2001) - WIN L1 ePcsWindows31Latin2( 2002) - WIN L2 ePcsWindows31Latin5( 2003) - WIN L5 ePcsHPRoman8( 2004) - ROMAN-8 ePcsAdobeStandardEncoding( 2005) - PS TEXT ePcsPC850Multilingual( 2009) - PC-850 ePcsPC858Multilingual( 2089) - PC-858 ePcsPCp852( 2010) - PC-852 ePcsPC8CodePage437( 2011) - PC-8 ePcsPC8DNDanishNorwegian( 2012) - PC-8DN ePcsHPPC8Turkish( 2014) - PC-8 TK ePcsHPLegal( 2017) - LEGAL ePcsHPDeskTop( 2021) - DESKTOP ePcsMacintosh( 2027) - MC TEXT ePcsPC77Baltic( 2087) - PC-775 ePcsWindows1257Baltic( 2257) - WINBALT" ::= { prtInterpreterEntry 10 } prtInterpreterDefaultCharSetOut OBJECT-TYPE SYNTAX INTEGER { ePcsNoDefault(2), ePcsASCII(3), ePcsHPRoman8(2004), ePcsAdobeStandardEncoding(2005) } ACCESS read-only STATUS optional DESCRIPTION "The default character set for data coming from this interpreter through the printer's output channel (i.e. the 'backchannel'). This value shall be (2) if there is no default." ::= { prtInterpreterEntry 11 } prtInterpreterTwoWay OBJECT-TYPE SYNTAX INTEGER { ePyes(3), ePno(4) } ACCESS read-only STATUS optional DESCRIPTION "Indicates whether or not this interpreter returns information back to the host." ::= { prtInterpreterEntry 12 } prtConsoleDisplayBufferText OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) ACCESS read-only STATUS optional DESCRIPTION "The content of a line in the logical display buffer of the operator's console of the printer. When a write operation occurs, normally a critical message, to one of the LineText strings, the agent should make that line displayable if a physical display is present. Writing a zero length string clears the line. It is an implementation-specific matter as to whether the agent allows a line to be overwritten before it has been cleared. Printer generated strings shall be in the localization specified by prtConsoleLocalization. Management Application generated strings should be localized by the Management Application. Additional information: In the case of a 2-line display message, prtConsoleDisplayBufferText.1 maps to the first line and prtConsoleDisplayBufferText.2 maps to the second. In the case of a 1-line display message, prtConsoleDisplayBufferText.1 maps to the first line and prtConsoleDisplayBufferText.2 return NULL." ::= { prtConsoleDisplayBufferEntry 2 } prtConsoleOnTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "This object, in conjunction with prtConsoleOffTime, defines the current status of the light. If both prtConsoleOnTime and prtConsoleOffTime are non-zero, the lamp is blinking and the values presented define the on time and off time, respectively, in milliseconds. If prtConsoleOnTime is zero and prtConsoleOffTime is non-zero, the lamp is off. If prtConsoleOffTime is zero and prtConsoleOnTime is non-zero, the lamp is on. If both values are zero the status of the lamp is undefined. Additional information: There are two control panel LEDs: Attention and Ready. When an LED blinks, it is on for one half second and off for one half second. The value used for this object is 500 when the LED is on or blinking, otherwise it is zero. When the LEDs are in a cycling state the value of this object for all LEDs is zero and the value for prtConsoleOffTime for all LEDs is zero." ::= { prtConsoleLightEntry 2 } prtConsoleOffTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "This object, in conjunction with prtConsoleOnTime, defines the current status of the light. If both prtConsoleOnTime and prtConsoleOffTime are non-zero, the lamp is blinking and the values presented define the on time and off time, respectively, in milliseconds. If prtConsoleOnTime is zero and prtConsoleOffTime is non-zero, the lamp is off. If prtConsoleOffTime is zero and prtConsoleOnTime is non-zero, the lamp is on. If both values are zero the status of the lamp is undefined. Additional information: There are 2 control panel LEDs: Attention and Ready. When an LED blinks, it is on for one half second and off for one half second. The value used for this object is 500 when the LED is off or blinking, otherwise it is zero. When the LEDs are in a cycling state the value of this object for all LEDs is zero and the value for prtConsoleOnTime for all LEDs is zero." ::= { prtConsoleLightEntry 3 } prtConsoleColor OBJECT-TYPE SYNTAX INTEGER { ePother(1), ePunknown(2), ePwhite(3), ePred(4), ePgreen(5), ePblue(6), ePcyan(7), ePmagenta(8), ePyellow(9), ePorange(10) } ACCESS read-only STATUS optional DESCRIPTION "The color of this light." ::= { prtConsoleLightEntry 4 } prtConsoleDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) ACCESS read-only STATUS optional DESCRIPTION "The vendor description or label of this light in the localization specified by prtConsoleLocalization." ::= { prtConsoleLightEntry 5 } END