-- ================================================================= -- Copyright (c) 2004-2011 Hangzhou H3C Tech. Co., Ltd. All rights reserved. -- -- Description: This MIB define objects for MPLS Te Tunnel. -- Reference: -- Version: V1.0 -- History: -- V1.0 2011-03-24 Created by fengnina 04924. -- ================================================================== H3C-TE-TUNNEL-MIB DEFINITIONS ::= BEGIN IMPORTS h3cCommon FROM HUAWEI-3COM-OID-MIB MplsTunnelIndex, MplsTunnelInstanceIndex, MplsExtendedTunnelId, MplsLabel FROM MPLS-TC-STD-MIB OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP FROM SNMPv2-CONF Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI RowPointer FROM SNMPv2-TC; h3cTeTunnel MODULE-IDENTITY LAST-UPDATED "201103240948Z" -- March 24, 2011 at 09:48 GMT ORGANIZATION "Hangzhou H3C Tech. Co., Ltd." CONTACT-INFO "Platform Team Hangzhou H3C Tech. Co., Ltd. Hai-Dian District Beijing P.R. China http://www.h3c.com Zip:100085" DESCRIPTION "This MIB contains managed object definitions for the Multiprotocol Label Switching (MPLS) Te Tunnel." ::= { h3cCommon 115 } -- -- Node definitions -- h3cTeTunnelScalars OBJECT IDENTIFIER ::= { h3cTeTunnel 1 } h3cTeTunnelMaxTunnelIndex OBJECT-TYPE SYNTAX MplsTunnelIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The max value of tunnel id is permitted configure on the device." ::= { h3cTeTunnelScalars 1 } h3cTeTunnelObjects OBJECT IDENTIFIER ::= { h3cTeTunnel 2 } h3cTeTunnelStaticCrlspTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cTeTunnelStaticCrlspEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information for static-crlsp, and through this to get detail information about this static-crlsp. Only support transit LSR and egress LSR." ::= { h3cTeTunnelObjects 1 } h3cTeTunnelStaticCrlspEntry OBJECT-TYPE SYNTAX H3cTeTunnelStaticCrlspEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry in this table describes static-crlsp information." INDEX { h3cTeTunnelStaticCrlspInLabel } ::= { h3cTeTunnelStaticCrlspTable 1 } H3cTeTunnelStaticCrlspEntry ::= SEQUENCE { h3cTeTunnelStaticCrlspInLabel MplsLabel, h3cTeTunnelStaticCrlspName OCTET STRING, h3cTeTunnelStaticCrlspStatus INTEGER, h3cTeTunnelStaticCrlspRole INTEGER, h3cTeTunnelStaticCrlspXCPointer RowPointer } h3cTeTunnelStaticCrlspInLabel OBJECT-TYPE SYNTAX MplsLabel MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is unique label value that manualy assigned. Uniquely identifies a static-crlsp. Managers should use this to obtain detail static-crlsp information." ::= { h3cTeTunnelStaticCrlspEntry 1 } h3cTeTunnelStaticCrlspName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The unique name assigned to the static-crlsp." ::= { h3cTeTunnelStaticCrlspEntry 2 } h3cTeTunnelStaticCrlspStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the actual status of this static-crlsp, The value must be up when the static-crlsp status is up and the value must be down when the static-crlsp status is down." ::= { h3cTeTunnelStaticCrlspEntry 3 } h3cTeTunnelStaticCrlspRole OBJECT-TYPE SYNTAX INTEGER { transit(1), tail(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicate the role of this static-crlsp. This value must be transit at transit point of the tunnel, and tail at terminating point of the tunnel." ::= { h3cTeTunnelStaticCrlspEntry 4 } h3cTeTunnelStaticCrlspXCPointer OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "This pointer unique identify a row of mplsXCTable. This value should be zeroDotZero when the static-crlsp is down. The mplsXCTable identifies the segments that compose this tunnel, their characteristics, and relationships to each other." ::= { h3cTeTunnelStaticCrlspEntry 5 } h3cTeTunnelCoTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cTeTunnelCoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information for Co-routed reverse crlsp and infomation of Co-routed bidirectional Tunnel Interface. If h3cCorouteTunnelLspInstance is zero, to obtain infomation of Co-routed bidirectional Tunnel Interface, otherwise to obtain Co-routed reverse crlsp infomation." ::= { h3cTeTunnelObjects 2 } h3cTeTunnelCoEntry OBJECT-TYPE SYNTAX H3cTeTunnelCoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry in this table describes Co-routed infomation of bidirectional Tunnel Interface and reserver lsp information." INDEX { h3cTeTunnelCoIndex, h3cTeTunnelCoLspInstance, h3cTeTunnelCoIngressLSRId, h3cTeTunnelCoEgressLSRId } ::= { h3cTeTunnelCoTable 1 } H3cTeTunnelCoEntry ::= SEQUENCE { h3cTeTunnelCoIndex MplsTunnelIndex, h3cTeTunnelCoLspInstance MplsTunnelInstanceIndex, h3cTeTunnelCoIngressLSRId MplsExtendedTunnelId, h3cTeTunnelCoEgressLSRId MplsExtendedTunnelId, h3cTeTunnelCoBiMode INTEGER, h3cTeTunnelCoReverseLspInstance MplsTunnelInstanceIndex, h3cTeTunnelCoReverseLspXCPointer RowPointer } h3cTeTunnelCoIndex OBJECT-TYPE SYNTAX MplsTunnelIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "Uniquely identifies a set of tunnel instances between a pair of ingress and egress LSRs that specified at originating point. This value should be equal to the value signaled in the Tunnel Id of the Session object." ::= { h3cTeTunnelCoEntry 1 } h3cTeTunnelCoLspInstance OBJECT-TYPE SYNTAX MplsTunnelInstanceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "When obtain infomation of Co-routed bidirectional Tunnel Interface, this vlaue should be zero. And this value must be LspID to obtain reverse crlsp information. Values greater than 0, but less than or equal to 65535, should be useless." ::= { h3cTeTunnelCoEntry 2 } h3cTeTunnelCoIngressLSRId OBJECT-TYPE SYNTAX MplsExtendedTunnelId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identity the ingress LSR associated with this tunnel instance. This vlaue is equal to the LsrID of originating endpoint." ::= { h3cTeTunnelCoEntry 3 } h3cTeTunnelCoEgressLSRId OBJECT-TYPE SYNTAX MplsExtendedTunnelId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identity of the egress LSR associated with this tunnel instance. This vlaue is equal to the LsrID of terminating point." ::= { h3cTeTunnelCoEntry 4 } h3cTeTunnelCoBiMode OBJECT-TYPE SYNTAX INTEGER { coroutedActive(1), coroutedPassive(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This vlaue indicated the bidirection mode of tunnel interface. The valuemust be coroutedActive at the originating point of the tunnel and coroutedPassive at the terminating point." ::= { h3cTeTunnelCoEntry 5 } h3cTeTunnelCoReverseLspInstance OBJECT-TYPE SYNTAX MplsTunnelInstanceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicated the reverse lsp instance, and should be equal to obverse lsp instance." ::= { h3cTeTunnelCoEntry 6 } h3cTeTunnelCoReverseLspXCPointer OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "This pointer unique index to mplsXCTable of the reverse lsp. The mplsXCTable identifies the segments that compose this tunnel, their characteristics, and relationships to each other. A value of zeroDotZero indicate that there is no crlsp assigned to this." ::= { h3cTeTunnelCoEntry 7 } h3cTeTunnelPsTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cTeTunnelPsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines some objects for managers to obtain TE tunnel Protection Switching group current status information." ::= { h3cTeTunnelObjects 3 } h3cTeTunnelPsEntry OBJECT-TYPE SYNTAX H3cTeTunnelPsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry in this table describes TE tunnel Protection Switching group infromation." INDEX { h3cTeTunnelPsIndex, h3cTeTunnelPsIngressLSRId, h3cTeTunnelPsEgressLSRId } ::= { h3cTeTunnelPsTable 1 } H3cTeTunnelPsEntry ::= SEQUENCE { h3cTeTunnelPsIndex MplsTunnelIndex, h3cTeTunnelPsIngressLSRId MplsExtendedTunnelId, h3cTeTunnelPsEgressLSRId MplsExtendedTunnelId, h3cTeTunnelPsProtectIndex MplsTunnelIndex, h3cTeTunnelPsProtectIngressLSRId MplsExtendedTunnelId, h3cTeTunnelPsProtectEgressLSRId MplsExtendedTunnelId, h3cTeTunnelPsProtectType INTEGER, h3cTeTunnelPsRevertiveMode INTEGER, h3cTeTunnelPsWtrTime Unsigned32, h3cTeTunnelPsHoldOffTime Unsigned32, h3cTeTunnelPsSwitchMode INTEGER, h3cTeTunnelPsWorkPathStatus INTEGER, h3cTeTunnelPsProtectPathStatus INTEGER, h3cTeTunnelPsSwitchResult INTEGER } h3cTeTunnelPsIndex OBJECT-TYPE SYNTAX MplsTunnelIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "Uniquely identifies a TE tunnel Protection Switching group instance. This value must be equal to the tunnel id of work tunnel instance." ::= { h3cTeTunnelPsEntry 1 } h3cTeTunnelPsIngressLSRId OBJECT-TYPE SYNTAX MplsExtendedTunnelId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identity the ingress LSR associated with work tunnel instance." ::= { h3cTeTunnelPsEntry 2 } h3cTeTunnelPsEgressLSRId OBJECT-TYPE SYNTAX MplsExtendedTunnelId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identity of the egress LSR associated with work tunnel instance." ::= { h3cTeTunnelPsEntry 3 } h3cTeTunnelPsProtectIndex OBJECT-TYPE SYNTAX MplsTunnelIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Uniquely identifies a TE tunnel Protection Switching group instance. This value must be equal to the tunnel id of TE tunnel Protection Switching group instance." ::= { h3cTeTunnelPsEntry 4 } h3cTeTunnelPsProtectIngressLSRId OBJECT-TYPE SYNTAX MplsExtendedTunnelId MAX-ACCESS read-only STATUS current DESCRIPTION "Identity the ingress LSR associated with TE tunnel Protection Switching group instance." ::= { h3cTeTunnelPsEntry 5 } h3cTeTunnelPsProtectEgressLSRId OBJECT-TYPE SYNTAX MplsExtendedTunnelId MAX-ACCESS read-only STATUS current DESCRIPTION "Identity of the egress LSR associated with TE tunnel Protection Switching group instance." ::= { h3cTeTunnelPsEntry 6 } h3cTeTunnelPsProtectType OBJECT-TYPE SYNTAX INTEGER { oneToOne(1), onePlusOne(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicated TE tunnel Protection Switching group type. The default value is oneToOne." DEFVAL { oneToOne } ::= { h3cTeTunnelPsEntry 7 } h3cTeTunnelPsRevertiveMode OBJECT-TYPE SYNTAX INTEGER { revertive(1), noRevertive(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicated protect switch mode. The value must be revertive or nonRevertive, default value is revertive. " DEFVAL { revertive } ::= { h3cTeTunnelPsEntry 8 } h3cTeTunnelPsWtrTime OBJECT-TYPE SYNTAX Unsigned32 (0..60) UNITS "30 seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The cycle time that switch to protect tunnel." DEFVAL { 24 } ::= { h3cTeTunnelPsEntry 9 } h3cTeTunnelPsHoldOffTime OBJECT-TYPE SYNTAX Unsigned32 (0..20) UNITS "500ms" MAX-ACCESS read-only STATUS current DESCRIPTION "This value is switchback delay time. When detected the work path fault, switch to protect path after this time." DEFVAL { 0 } ::= { h3cTeTunnelPsEntry 10 } h3cTeTunnelPsSwitchMode OBJECT-TYPE SYNTAX INTEGER { uniDirectional(1), biDirectional(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicated TE tunnel Protection Switching group switch mode." DEFVAL { uniDirectional } ::= { h3cTeTunnelPsEntry 11 } h3cTeTunnelPsWorkPathStatus OBJECT-TYPE SYNTAX INTEGER { none(1), noDefect(2), inDefect(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates work path status. none, noDefect, inDefect will be used." ::= { h3cTeTunnelPsEntry 12 } h3cTeTunnelPsProtectPathStatus OBJECT-TYPE SYNTAX INTEGER { none(1), noDefect(2), inDefect(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates protect path status. none, noDefect, inDefect(3) will be used." ::= { h3cTeTunnelPsEntry 13 } h3cTeTunnelPsSwitchResult OBJECT-TYPE SYNTAX INTEGER { workPath(1), protectPath(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicated current using path is work path or protect path." ::= { h3cTeTunnelPsEntry 14 } h3cTeTunnelNotifications OBJECT IDENTIFIER ::= { h3cTeTunnel 3 } h3cTeTunnelNotificationsPrefix OBJECT IDENTIFIER ::= { h3cTeTunnelNotifications 0 } h3cTeTunnelPsSwitchWtoP NOTIFICATION-TYPE OBJECTS { h3cTeTunnelPsWorkPathStatus, h3cTeTunnelPsProtectPathStatus } STATUS current DESCRIPTION "This notification is generated when protect workgroup switch from work tunnel to protect tunnel." ::= { h3cTeTunnelNotificationsPrefix 1 } h3cTeTunnelPsSwitchPtoW NOTIFICATION-TYPE OBJECTS { h3cTeTunnelPsWorkPathStatus, h3cTeTunnelPsProtectPathStatus } STATUS current DESCRIPTION "This notification is generated when protect workgroup switch from protect tunnel to work tunnel." ::= { h3cTeTunnelNotificationsPrefix 2 } h3cTeTunnelConformance OBJECT IDENTIFIER ::= { h3cTeTunnel 4 } h3cTeTunnelCompliances OBJECT IDENTIFIER ::= { h3cTeTunnelConformance 1 } h3cTeTunnelCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMP." MODULE -- this module MANDATORY-GROUPS { h3cTeTunnelNotificationsGroup, h3cTeTunnelScalarsGroup, h3cTeTunnelStaticCrlspGroup, h3cTeTunnelCorouteGroup, h3cTeTunnelPsGroup } ::= { h3cTeTunnelCompliances 1 } h3cTeTunnelGroups OBJECT IDENTIFIER ::= { h3cTeTunnelConformance 2 } h3cTeTunnelNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { h3cTeTunnelPsSwitchPtoW, h3cTeTunnelPsSwitchWtoP } STATUS current DESCRIPTION "This group contains MPLS Te Tunnel traps." ::= { h3cTeTunnelGroups 1 } h3cTeTunnelScalarsGroup OBJECT-GROUP OBJECTS { h3cTeTunnelMaxTunnelIndex } STATUS current DESCRIPTION "Scalar object needed to implement MPLS te tunnels." ::= { h3cTeTunnelGroups 2 } h3cTeTunnelStaticCrlspGroup OBJECT-GROUP OBJECTS { h3cTeTunnelStaticCrlspName, h3cTeTunnelStaticCrlspStatus, h3cTeTunnelStaticCrlspRole, h3cTeTunnelStaticCrlspXCPointer } STATUS current DESCRIPTION "Objects for quering static-crlsp information." ::= { h3cTeTunnelGroups 3 } h3cTeTunnelCorouteGroup OBJECT-GROUP OBJECTS { h3cTeTunnelCoBiMode, h3cTeTunnelCoReverseLspInstance, h3cTeTunnelCoReverseLspXCPointer } STATUS current DESCRIPTION "Objects for quering Co-routed reverse crlsp information." ::= { h3cTeTunnelGroups 4 } h3cTeTunnelPsGroup OBJECT-GROUP OBJECTS { h3cTeTunnelPsProtectIndex, h3cTeTunnelPsProtectIngressLSRId, h3cTeTunnelPsProtectEgressLSRId, h3cTeTunnelPsProtectType, h3cTeTunnelPsRevertiveMode, h3cTeTunnelPsWtrTime, h3cTeTunnelPsHoldOffTime, h3cTeTunnelPsSwitchMode, h3cTeTunnelPsWorkPathStatus, h3cTeTunnelPsProtectPathStatus, h3cTeTunnelPsSwitchResult } STATUS current DESCRIPTION "Objects for quering protect workgroup information." ::= { h3cTeTunnelGroups 5 } END