-- ***************************************************************** -- EKINOPS-pmora14.TXT: MIB -- --MIB Part Number:3MI00216AAAB --MIB Version:01 -- -- Copyright (c) 2016 by Ekinops -- All rights reserved. -- -- ***************************************************************** EKINOPS-Pmora14-MIB DEFINITIONS ::= BEGIN IMPORTS ekinops, EkiState, EkiOnOff, EkiMode, EkiProtocol, EkiApiState, EkiSynchroMode, EkiMeasureType FROM EKINOPS-MIB MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32, Counter32, IpAddress FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC; modulepmora14 MODULE-IDENTITY LAST-UPDATED "201605230000Z" ORGANIZATION "Ekinops" CONTACT-INFO "Ekinops 3, rue Blaise Pascal F-22300 Lannion / FRANCE Tel : +33 (0)2 96 05 00 30 Fax : +33 (0)2 96 48 62 39 E-mail: support@ekinops.net" DESCRIPTION "Creation" REVISION "201508310000Z" DESCRIPTION "Creation" REVISION "201605230000Z" DESCRIPTION "New AlarmType – synthesisAlarm (12)" ::= { ekinops 72 } --- ***************************************************** --- LEAF LEVEL 2 --- ***************************************************** pmora14alarms OBJECT IDENTIFIER ::= { modulepmora14 2 } pmora14AlmOther OBJECT IDENTIFIER ::= { pmora14alarms 1 } pmora14AlmOtherNurg OBJECT IDENTIFIER ::= { pmora14AlmOther 1 } pmora14AlmOtherUrg OBJECT IDENTIFIER ::= { pmora14AlmOther 2 } pmora14AlmOtherCrit OBJECT IDENTIFIER ::= { pmora14AlmOther 3 } pmora14AlmClient OBJECT IDENTIFIER ::= { pmora14alarms 2 } pmora14AlmClientNurg OBJECT IDENTIFIER ::= { pmora14AlmClient 1 } pmora14AlmClientUrg OBJECT IDENTIFIER ::= { pmora14AlmClient 2 } pmora14AlmClientCrit OBJECT IDENTIFIER ::= { pmora14AlmClient 3 } pmora14AlmLine OBJECT IDENTIFIER ::= { pmora14alarms 3 } pmora14AlmLineNurg OBJECT IDENTIFIER ::= { pmora14AlmLine 1 } pmora14AlmLineUrg OBJECT IDENTIFIER ::= { pmora14AlmLine 2 } pmora14AlmLineCrit OBJECT IDENTIFIER ::= { pmora14AlmLine 3 } pmora14measures OBJECT IDENTIFIER ::= { modulepmora14 3 } pmora14MesrOther OBJECT IDENTIFIER ::= { pmora14measures 1 } pmora14MesrClient OBJECT IDENTIFIER ::= { pmora14measures 2 } pmora14MesrLine OBJECT IDENTIFIER ::= { pmora14measures 3 } pmora14counters OBJECT IDENTIFIER ::= { modulepmora14 4 } pmora14CntOther OBJECT IDENTIFIER ::= { pmora14counters 1 } pmora14CntClient OBJECT IDENTIFIER ::= { pmora14counters 2 } pmora14CntLine OBJECT IDENTIFIER ::= { pmora14counters 3 } pmora14controlsWrite OBJECT IDENTIFIER ::= { modulepmora14 6 } pmora14CtrlOther OBJECT IDENTIFIER ::= { pmora14controlsWrite 1 } pmora14CtrlClient OBJECT IDENTIFIER ::= { pmora14controlsWrite 2 } pmora14CtrlLine OBJECT IDENTIFIER ::= { pmora14controlsWrite 3 } pmora14ri OBJECT IDENTIFIER ::= { modulepmora14 7 } pmora14riTable OBJECT IDENTIFIER ::= { pmora14ri 1 } pmora14Config OBJECT IDENTIFIER ::= { modulepmora14 9 } pmora14traps OBJECT IDENTIFIER ::= { modulepmora14 10 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- TEXTUAL-CONVENTION --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** Pmora14PumpsMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different modes on the Raman Module" SYNTAX INTEGER { ora14maxpowermode(0), ora14gaincontrolmode(1), ora14manualcontrolmode(2) } Pmora14AprMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different modes on APR" SYNTAX INTEGER { ora14aproffmode(0), ora14aproscmode(1), ora14aprbrratiomode(2) ora14aprsbandmode(3) ora14aprfullmode(4) } Pmora14LineFiberTypeMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different modes on APR" SYNTAX INTEGER { ora14g652mode(0), ora14g655leafmode(1), ora14g655truewavemode(2) ora14g654mode(3) ora14g653mode(4) } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- REMOTE INVENTORY --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** pmora14RinvReloadInventory OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Reload the inventory: This OID triggers an inventory reload." ::= { pmora14ri 2 } pmora14RinvHwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "HW platform description: This OID contains the description of the Hardware platform." ::= { pmora14ri 3 } pmora14RinvModulePlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module platform description: This OID contains the description of the Module." ::= { pmora14ri 4 } pmora14RinvSwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SW platform description: This OID contains the description of the Software platform." ::= { pmora14ri 5 } pmora14RinvGwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "GW platform description: This OID contains the description of the gateware platform." ::= { pmora14ri 6 } pmora14RinvLineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmora14RinvLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of the Lines on the selected module" ::= { pmora14riTable 2 } pmora14RinvLineEntry OBJECT-TYPE SYNTAX Pmora14RinvLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the Line table" INDEX { pmora14RinvLineIndex } ::= { pmora14RinvLineTable 1 } Pmora14RinvLineEntry::= SEQUENCE { pmora14RinvLineIndex Integer32, pmora14RinvportLine DisplayString } pmora14RinvLineIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for Line table" ::= { pmora14RinvLineEntry 1 } pmora14RinvportLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the Line: This OID contains the inventory for the Line" ::= { pmora14RinvLineEntry 2 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ALARMS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synthAlm0 article --- ***************************************************** pmora14AlmsynthAlm0 OBJECT IDENTIFIER ::= { pmora14AlmOtherCrit 0 } pmora14AlmDefFuseB OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition Status of the Fuse B DEF_FUSE_B powerProblem (36) equipmentAlarm (5) (2) " ::= { pmora14AlmsynthAlm0 16 } pmora14AlmDefFuseA OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition Status of the Fuse A DEF_FUSE_A powerProblem (36) equipmentAlarm (5) (2) " ::= { pmora14AlmsynthAlm0 15 } pmora14AlmInitNotCompl OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Raman Module Not Initialized :This OID indicates that the initialisation of the Raman module is not completed This status indicates if the Raman has been correctly initialized INIT_NOT_COMPL equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmora14AlmsynthAlm0 10 } pmora14AlmModGlobFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Failure :This OID is set on detection of a failure originating from the PM This alarm MOD_GLOB_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmora14AlmsynthAlm0 9 } pmora14AlmAprOn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Automatic Power Reduction :This OID indicates that the APR algorithm has been operated and the output of the lasers are shutdown The APR algorithm has been completed APR_ON other (1) other (1) (2) " ::= { pmora14AlmsynthAlm0 2 } pmora14AlmMaintenanceMode OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Maintenance Mode :This OID indicates that the PM is in maintenance mode This status indiates if the module is currently in maintenance mode MAINTENANCE_MODE other (1) other (1) (2) " ::= { pmora14AlmsynthAlm0 1 } --- ***************************************************** --- LEAF for the synthAlm2 article --- ***************************************************** pmora14AlmsynthAlm2 OBJECT IDENTIFIER ::= { pmora14AlmOtherNurg 2 } pmora14AlmConfTableLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. CONF_TABLE_LOAD other (1) other (1) (2) " ::= { pmora14AlmsynthAlm2 3 } pmora14AlmInvUpload OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Inventory Upload :This OID is at 1 during the uploading of PM inventory information. INV_UPLOAD other (1) other (1) (2) " ::= { pmora14AlmsynthAlm2 2 } pmora14AlmConfTableSave OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. CONF_TABLE_SAVE other (1) other (1) (2) " ::= { pmora14AlmsynthAlm2 1 } --- ***************************************************** --- LEAF for the synthAlm7 article --- ***************************************************** pmora14AlmsynthAlm7 OBJECT IDENTIFIER ::= { pmora14AlmLineUrg 7 } pmora14AlmLineFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port Failure :This OID indicates a failure on the line port This alarm indicates a failure on the Line port LINE_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmora14AlmsynthAlm7 12 } pmora14AlmPumpsTxOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pumps Laser Shutdown :This OID indicates the power of the pumps are both on This status indicates if the pumps lasers are both OFF PUMPS_TX_OFF pumpFailure (39) other (1) (2) " ::= { pmora14AlmsynthAlm7 5 } pmora14AlmLineHwFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue This alarm indicates a failure on the HW Line port LINE_HW_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmora14AlmsynthAlm7 4 } --- ***************************************************** --- LEAF for the clientOraAlarms1 article --- ***************************************************** pmora14AlmclientOraAlarms1 OBJECT IDENTIFIER ::= { pmora14AlmLineUrg 32 } pmora14AlmPump2TecAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 2 TEC Alarm :This OID indicates a transmit laser fail on pump 2 This alarm indicates if the laser of the pump2 is in fail condition PUMP2_TEC_ALARM performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmora14AlmclientOraAlarms1 4 } pmora14AlmPump1TecAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 1 TEC Alarm :This OID indicates a transmit laser fail on pump 1 This alarm indicates if the laser of the pump1 is in fail condition PUMP1_TEC_ALARM performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmora14AlmclientOraAlarms1 3 } pmora14AlmPump2CurrentHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 2 Current High Alarm :This OID indicates the Pump2 current is higher than the alarm threshold This alarm indicates if the pump2 current is higher than the alarm threshold PUMP2_CURRENT_HIGH_ALARM performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmora14AlmclientOraAlarms1 2 } pmora14AlmPump1CurrentHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 1 Current High Alarm :This OID indicates the Pump1 current is higher than the alarm threshold This alarm indicates if the pump1 current is higher than the alarm threshold PUMP1_CURRENT_HIGH_ALARM performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmora14AlmclientOraAlarms1 1 } --- ***************************************************** --- LEAF for the clientOraaWarnings article --- ***************************************************** pmora14AlmclientOraaWarnings OBJECT IDENTIFIER ::= { pmora14AlmLineNurg 33 } pmora14AlmPump2TecWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 2 TEC Warning :This OID indicates a transmit laser fail on pump 2 This alarm indicates if the laser of the pump2 is in fail condition PUMP2_TEC_WARNING performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmora14AlmclientOraaWarnings 4 } pmora14AlmPump1TecWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 1 TEC Warning :This OID indicates a transmit laser fail on pump 1 This alarm indicates if the laser of the pump1 is in fail condition PUMP1_TEC_WARNING performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmora14AlmclientOraaWarnings 3 } pmora14AlmPump2CurrentHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 2 Current High Warning :This OID indicates the Pump2 current is higher than the warning threshold This alarm indicates if the pump2 current is higher than the warning threshold PUMP2_CURRENT_HIGH_WARNING performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmora14AlmclientOraaWarnings 2 } pmora14AlmPump1CurrentHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 1 Current High Warning :This OID indicates the Pump1 current is higher than the warning threshold This alarm indicates if the pump1 current is higher than the warning threshold PUMP1_CURRENT_HIGH_WARNING performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmora14AlmclientOraaWarnings 1 } --- ***************************************************** --- LEAF for the pump1Alarms article --- ***************************************************** pmora14Almpump1Alarms OBJECT IDENTIFIER ::= { pmora14AlmLineCrit 35 } pmora14AlmPump1TecFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 1 TEC Fail :This OID indicates that the TEC is in fail condition on pump 1 This alarm indicates if the TEC of the pump1 is in fail condition PUMP1_TEC_FAIL pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmora14Almpump1Alarms 2 } pmora14AlmPump1Shutdown OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 1 Laser Shutdown :This OID indicates that the pump 1 is shutdown This status indicates if the pump1 is shutdown PUMP1_SHUTDOWN informationalStatus(1000) other(1) (2) " ::= { pmora14Almpump1Alarms 1 } --- ***************************************************** --- LEAF for the pump2Alarms article --- ***************************************************** pmora14Almpump2Alarms OBJECT IDENTIFIER ::= { pmora14AlmLineCrit 36 } pmora14AlmPump2TecFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 2 TEC Fail :This OID indicates that the TEC is in fail condition on pump 2 This alarm indicates if the TEC of the pump2 is in fail condition PUMP2_TEC_FAIL pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmora14Almpump2Alarms 2 } pmora14AlmPump2Shutdown OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 2 Laser Shutdown :This OID indicates that the pump 2 is shutdown This status indicates if the pump2 is shutdown PUMP2_SHUTDOWN informationalStatus(1000) other(1) (2) " ::= { pmora14Almpump2Alarms 1 } --- ***************************************************** --- LEAF for the fiberAlarms article --- ***************************************************** pmora14AlmfiberAlarms OBJECT IDENTIFIER ::= { pmora14AlmLineUrg 72 } pmora14AlmStartupHighBackReflection OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Startup High Back Reflection :This OID indicates that a High Back Reflection ratio is too high on startup This alarm indicates that a High Back Reflection ratio is too high on startup STARTUP_HIGH_BACK_REFLECTION equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmora14AlmfiberAlarms 9 } pmora14AlmStartupLowSBand OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Startup Low S Band :This OID indicates that the input power over the S-Band is too low on startup This alarm indicates that the input power over the S-Band is too low on startup STARTUP_LOW_S_BAND equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmora14AlmfiberAlarms 8 } pmora14AlmPartialAprSecurity OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Partial APR Security :This OID indicates at least one APR security switch has been disabled This alarm indicates at least one APR security switch has been disabled PARTIAL_APR_SECURITY other (1) equipmentAlarm (5) (2) " ::= { pmora14AlmfiberAlarms 7 } pmora14AlmOscFailed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Osc Failed :This OID indicates that an OSC Loss of Frame is reported by the linked HCS amplifier This alarm indicates that an OSC Loss of Frame is reported by the linked HCS amplifier OSC_FAILED equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmora14AlmfiberAlarms 6 } pmora14AlmLineConnectorUnlocked OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Connector Unlocked :This OID indicates the Fonrt panel Line connector is not locked This alarm indicates the Fonrt panel Line connector is not locked LINE_CONNECTOR_UNLOCKED other (1) operationalViolation (8) (2) " ::= { pmora14AlmfiberAlarms 5 } pmora14AlmHighBackReflection OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " High Back Reflection :This OID indicates that a High Back Reflection ratio is too high This alarm indicates that a High Back Reflection ratio is too high HIGH_BACK_REFLECTION other (1) operationalViolation (8) (2) " ::= { pmora14AlmfiberAlarms 4 } pmora14AlmCBandLossOfSignal OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " C Band Loss Of Signal :This OID indicates that a Loss of Signal is detected over the C-Band This alarm indicates that a Loss of Signal is detected over the C-Band C_BAND_LOSS_OF_SIGNAL lossOfSignal (30) operationalViolation (8) (2) " ::= { pmora14AlmfiberAlarms 3 } pmora14AlmLowSBand OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Low S Band :This OID indicates that the input power over the S-Band is too low This alarm indicates that the input power over the S-Band is too low LOW_S_BAND other (1) operationalViolation (8) (2) " ::= { pmora14AlmfiberAlarms 2 } pmora14AlmSBandLossOfSignal OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " S Band Loss Of Signal :This OID indicates that a Loss of Signal is detected over the S-Band This alarm indicates that a Loss of Signal is detected over the S-Band S_BAND_LOSS_OF_SIGNAL lossOfSignal (30) operationalViolation (8) (2) " ::= { pmora14AlmfiberAlarms 1 } --- ***************************************************** --- LEAF for the moduleAlarms article --- ***************************************************** pmora14AlmmoduleAlarms OBJECT IDENTIFIER ::= { pmora14AlmOtherUrg 74 } pmora14AlmModuleTempHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Temperature High Alarm :This OID indicates that the PM temperature is higher than the alarm threshold This alarm indicates if the module temperature is higher than the alarm threshold MODULE_TEMP_HIGH_ALARM temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmora14AlmmoduleAlarms 2 } pmora14AlmModuleTempLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Temperature Low Alarm :This OID indicates that the PM temperature if lower than the alarm threshold This alarm indicates if the module temperature is lower than the alarm threshold MODULE_TEMP_LOW_ALARM temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmora14AlmmoduleAlarms 1 } --- ***************************************************** --- LEAF for the moduleWarnings article --- ***************************************************** pmora14AlmmoduleWarnings OBJECT IDENTIFIER ::= { pmora14AlmOtherNurg 75 } pmora14AlmModuleTempHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Temperature High Warning :This OID indicates that the PM temperature if higher than the Warning threshold This alarm indicates if the module temperature is higher than the warning threshold MODULE_TEMP_HIGH_WARNING temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmora14AlmmoduleWarnings 2 } pmora14AlmModuleTempLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Temperature Low Warning :This OID indicates that the PM temperature if lower than the Warning threshold This alarm indicates if the module temperature is lower than the warning threshold MODULE_TEMP_LOW_WARNING temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmora14AlmmoduleWarnings 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONTROLS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synth0 article --- ***************************************************** pmora14Ctrlsynth0 OBJECT IDENTIFIER ::= { pmora14CtrlOther 0 } pmora14CtrlConfClear OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. This control restores the default configuration of the module " ::= { pmora14Ctrlsynth0 13 } pmora14CtrlConfFlash OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. This control saves the customer configuration on the module " ::= { pmora14Ctrlsynth0 9 } pmora14CtrlConfLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Load Configuration Tables :When set this enables loading from flash configuration1 into the module. " ::= { pmora14Ctrlsynth0 1 } --- ***************************************************** --- LEAF for the swMgnt article --- ***************************************************** pmora14CtrlswMgnt OBJECT IDENTIFIER ::= { pmora14CtrlOther 5 } pmora14CtrlWarmReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unchanged. This control initiates a warm reset of the module. " ::= { pmora14CtrlswMgnt 3 } pmora14CtrlColdReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start-up. This control initiates a cold reset of the module. " ::= { pmora14CtrlswMgnt 2 } --- ***************************************************** --- LEAF for the aprMode article --- ***************************************************** pmora14CtrlaprMode OBJECT-TYPE SYNTAX Pmora14AprMode MAX-ACCESS read-write STATUS current DESCRIPTION " APR Mode :This OID selects the APR Mode This control initiates the APR Mode " ::= { pmora14CtrlOther 16 } --- ***************************************************** --- LEAF for the ledTest article --- ***************************************************** pmora14CtrlledTest OBJECT IDENTIFIER ::= { pmora14CtrlOther 73 } pmora14CtrlLedOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Leds Off :This OID switches off all the Leds as a test feature. This control initiates a test leds turning all the LEDs to OFF " ::= { pmora14CtrlledTest 3 } pmora14CtrlRedLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Red Leds Test :This OID switches on all the red Leds as a test feature. This control initiates a test leds turning all the LEDs to red " ::= { pmora14CtrlledTest 2 } pmora14CtrlGreenLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Green Leds Test :This OID switches on all the green Leds as a test feature. This control initiates a test leds turning all the LEDs to green " ::= { pmora14CtrlledTest 1 } --- ***************************************************** --- LEAF for the maintMode article --- ***************************************************** pmora14CtrlmaintMode OBJECT IDENTIFIER ::= { pmora14CtrlOther 74 } pmora14CtrlMaintenance OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Maintenance Mode :This OID sets the PM in maintenance mode This control enables the maintenance mode of the module " ::= { pmora14CtrlmaintMode 1 } --- ***************************************************** --- LEAF for the aprManualRestart article --- ***************************************************** pmora14CtrlaprManualRestart OBJECT IDENTIFIER ::= { pmora14CtrlLine 75 } pmora14CtrlAprManualRestart OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " APR Manual Restart :This OID initiates the Restart mechanism to retrieve from the APR state. This control initiates the Restart mechanism to retrieve from the APR state. " ::= { pmora14CtrlaprManualRestart 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- COUNTERS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** pmora14CntCountersReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Counters Reset:This OID resets and restarts all the counters" ::= { pmora14counters 259 } pmora14CntCountersStop OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Counters stop:This OID stops all the counters" ::= { pmora14counters 260 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- MEASURES --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the pump1CurrentMeas article --- ***************************************************** pmora14Mesrpump1CurrentMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 1 Laser Current :This OID gives the Pump1 laser current (Current =AV/10) (Unit = mA) This measure gives the Pump1 Laser current " ::= { pmora14MesrLine 64 } --- ***************************************************** --- LEAF for the pump1PowerMeas article --- ***************************************************** pmora14Mesrpump1PowerMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 1 Tx Power :This OID gives the Pump1 power value (Power =AV/20) (Unit = mW) This measure gives the Pump1 Power value " ::= { pmora14MesrLine 65 } --- ***************************************************** --- LEAF for the pump1TempMeas article --- ***************************************************** pmora14Mesrpump1TempMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 1 Temperature :This OID gives the Pump1 TEC temperature (Temperature =AV/256) (Unit = C) This measure gives the Pump1 TEC temperature " ::= { pmora14MesrLine 66 } --- ***************************************************** --- LEAF for the pump1TecCurrentMeas article --- ***************************************************** pmora14Mesrpump1TecCurrentMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 1 TEC Current :This OID gives the Pump1 TEC current (Current =AV/10) (Unit = mA) This measure gives the Pump1 TEC current " ::= { pmora14MesrLine 67 } --- ***************************************************** --- LEAF for the pump2CurrentMeas article --- ***************************************************** pmora14Mesrpump2CurrentMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 2 Laser Current :This OID gives the Pump2 laser current (Current =AV/10) (Unit = mA) This measure gives the Pump2 Laser current " ::= { pmora14MesrLine 68 } --- ***************************************************** --- LEAF for the pump2PowerMeas article --- ***************************************************** pmora14Mesrpump2PowerMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 2 Tx Power :This OID gives the Pump2 power value (Power =AV/20) (Unit = mW) This measure gives the Pump2 Power value " ::= { pmora14MesrLine 69 } --- ***************************************************** --- LEAF for the pump2TempMeas article --- ***************************************************** pmora14Mesrpump2TempMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 2 Temperature :This OID gives the Pump2 TEC temperature (Temperature =AV/256) (Unit = C) This measure gives the Pump2 TEC temperature " ::= { pmora14MesrLine 70 } --- ***************************************************** --- LEAF for the pump2TecCurrentMeas article --- ***************************************************** pmora14Mesrpump2TecCurrentMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pump 2 TEC Current :This OID gives the Pump2 TEC current (Current =AV/10) (Unit = mA) This measure gives the Pump2 TEC current " ::= { pmora14MesrLine 71 } --- ***************************************************** --- LEAF for the totalPumpsPower article --- ***************************************************** pmora14MesrtotalPumpsPower OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Total Pumps Power :This OID indicates the total pumps power (Power = AV/20) (Unit = mW) This measure indicates the total pump power " ::= { pmora14MesrLine 72 } --- ***************************************************** --- LEAF for the inputCBandPower article --- ***************************************************** pmora14MesrinputCBandPower OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Input C Band Power :This OID indicates the input power over the C-Band (Power =(AV-32768)*0,005) (Unit = dBm) This measure indicates the input power over the C-Band " ::= { pmora14MesrLine 73 } --- ***************************************************** --- LEAF for the sBandPower article --- ***************************************************** pmora14MesrsBandPower OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " S Band Power :This OID indicates the input power over the S-band (Power =(AV-32768)*0,005) (Unit = dBm) This measure indicates the input power over the S-Band " ::= { pmora14MesrLine 74 } --- ***************************************************** --- LEAF for the backReflectionPumpPower article --- ***************************************************** pmora14MesrbackReflectionPumpPower OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Back Reflection Pump Power :This OID indicates the Back Reflection Pump power (Power =(AV-32768)*0,005) (Unit = dBm) This measure indicates the Back Reflection Pump power " ::= { pmora14MesrLine 75 } --- ***************************************************** --- LEAF for the backReflectionPumpRatio article --- ***************************************************** pmora14MesrbackReflectionPumpRatio OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Back Reflection Pump Ratio :This OID indicates the Back Relfection Pump ration (Power =(AV-32768)*0,005) (Unit = dB) This measure indicates the Back Reflection Pump ratio " ::= { pmora14MesrLine 76 } --- ***************************************************** --- LEAF for the pmTempMeas article --- ***************************************************** pmora14MesrpmTempMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Module Temperature :This OID gives the temperature of the PM (Temperature =AV/256) (Unit = C) This measure gives the temperature of the module " ::= { pmora14MesrOther 80 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONFIG --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the table Group noValue --- ***************************************************** pmora14CfgNoValue OBJECT IDENTIFIER ::= { pmora14Config 1 } --- ***************************************************** --- LEAF for the table 2191 --- ***************************************************** pmora14tablelineStartup OBJECT IDENTIFIER ::= { pmora14CfgNoValue 1 } pmora14CfgoraModuleCtrl OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on the module :This OID configures the default initialisation settings of the Raman module " ::= { pmora14tablelineStartup 2 } pmora14CfgautoRestartDelay OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on autorestart delay :This OID configures the default period on the autorestart " ::= { pmora14tablelineStartup 3 } pmora14CfgramanGain OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on the Raman Gain :This OID configures the default gain on the Raman module " ::= { pmora14tablelineStartup 4 } pmora14CfgramanMode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Raman mode :This OID configures the default Raman mode " ::= { pmora14tablelineStartup 5 } pmora14CfgtiltValue OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on the tilt value :This OID configures the default tilt on the line amplifier. " ::= { pmora14tablelineStartup 6 } pmora14CfghighBackreflectionThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on the backreflection threshold :This OID configures the default threshold on the backreflection " ::= { pmora14tablelineStartup 7 } pmora14CfgsBandThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on the S band threshold :This OID configures the default threshold on the S band " ::= { pmora14tablelineStartup 8 } pmora14Cfgpump1ManualPower OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on the pump power :This OID configures the default value on the power " ::= { pmora14tablelineStartup 9 } pmora14Cfgpump2ManualPower OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on the pump power :This OID configures the default value on the power " ::= { pmora14tablelineStartup 10 } --- ***************************************************** --- LEAF for the table Group labels --- ***************************************************** pmora14CfgLabels OBJECT IDENTIFIER ::= { pmora14Config 2 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmora14CfgLabelclientTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmora14CfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmora14CfgLabels 1 } pmora14CfgLabelclientEntry OBJECT-TYPE SYNTAX Pmora14CfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pmora14CfgLabelclientIndex } ::= { pmora14CfgLabelclientTable 1 } Pmora14CfgLabelclientEntry ::= SEQUENCE { pmora14CfgLabelclientIndex INTEGER, pmora14CfgLabelclientPortn DisplayString } pmora14CfgLabelclientIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelclient table " ::= { pmora14CfgLabelclientEntry 1 } pmora14CfgLabelclientPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. " ::= { pmora14CfgLabelclientEntry 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmora14CfgLabellineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmora14CfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmora14CfgLabels 2 } pmora14CfgLabellineEntry OBJECT-TYPE SYNTAX Pmora14CfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pmora14CfgLabellineIndex } ::= { pmora14CfgLabellineTable 1 } Pmora14CfgLabellineEntry ::= SEQUENCE { pmora14CfgLabellineIndex INTEGER, pmora14CfgLabellinePortn DisplayString } pmora14CfgLabellineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelline table " ::= { pmora14CfgLabellineEntry 1 } pmora14CfgLabellinePortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. " ::= { pmora14CfgLabellineEntry 3 } pmora14CfgWriteConfiguration OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Write configuration to module:This OID writes the complete configuration to the module" ::= { pmora14Config 257 } --- ***************************************************** --- TRAP OBJECTS --- ***************************************************** pmora14trapBoardNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last module which generates a trap" ::= { pmora14traps 4 } --- ***************************************************** --- GLOBAL TRAPS --- ***************************************************** pmora14LineTrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pmora14AlmLineFail, pmora14AlmLineHwFail, pmora14trapBoardNumber} STATUS current --&FILTNAME "PMORA14 Line Fail ON" --&ACTIONS { log, critical } --&MATCH { pmora14AlmLineFail "on", pmora14AlmLineHwFail "*", pmora14trapBoardNumber "$3"} --&MESG "Critical Alarm appears on PMORA14 in slot $3 ($A)" --&FILTNAME "PMORA14 Line HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pmora14AlmLineFail "*", pmora14AlmLineHwFail "on", pmora14trapBoardNumber "$3"} --&MESG "Critical Alarm appears on PMORA14 in slot $3 ($A)" DESCRIPTION "Critical Line default is activated" ::= { pmora14traps 34 } pmora14LineTrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pmora14AlmLineFail, pmora14AlmLineHwFail, pmora14trapBoardNumber} STATUS current --&FILTNAME "PMORA14 Line Fail OFF" --&ACTIONS { log, normal } --&CLEARS {"PMORA14 Line Fail ON"} --&MATCH { pmora14AlmLineFail "on", pmora14AlmLineHwFail "*", pmora14trapBoardNumber "$3"} --&MESG "Critical Alarm disappears on PMORA14 in slot $3 ($A)" --&FILTNAME "PMORA14 Line HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pmora14AlmLineFail "*", pmora14AlmLineHwFail "on", pmora14trapBoardNumber "$3"} --&MESG "Critical Alarm disappears on PMORA14 in slot $3 ($A)" DESCRIPTION "Critical Line default disappeared" ::= { pmora14traps 35 } --- ***************************************************** --- PORTS TRAPS --- ***************************************************** --- ***************************************************** --- HW TRAPS --- ***************************************************** pmora14PowerTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmora14AlmDefFuseB, pmora14AlmDefFuseA , pmora14trapBoardNumber} STATUS current --&FILTNAME "PMORA Fuse A Fail ON" --&ACTIONS { log, major } --&MATCH { pmora14AlmDefFuseB "*", pmora14AlmDefFuseA "on", pmora14trapBoardNumber "$3"} --&MESG "Power Input A Fail on PMORA in Slot $3 ($A)" --&FILTNAME "PMORA Fuse B Fail ON" --&ACTIONS { log, major } --&MATCH { pmora14AlmDefFuseB "on", pmora14AlmDefFuseA "*", pmora14trapBoardNumber "$3"} --&MESG "Power Input B Fail on PMORA in Slot $3 ($A)" DESCRIPTION "Urgent power supply default is activated" ::= { pmora14traps 50 } pmora14PowerTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmora14AlmDefFuseB, pmora14AlmDefFuseA , pmora14trapBoardNumber} STATUS current --&FILTNAME "PMORA Fuse A&B Fail OFF" --&ACTIONS { log, normal} --&CLEARS { "PMORA Fuse A Fail ON", "PMORA Fuse B Fail ON" } --&MATCH { pmora14AlmDefFuseB "on", pmora14AlmDefFuseA "on", pmora14trapBoardNumber "$3"} --&MESG "Power Inputs A and B Present on PMORA in Slot $3 ($A)" DESCRIPTION "Urgent power supply default disappeared" ::= { pmora14traps 51 } END