-- ----------------------------------------------------------------------------- -- MIB NAME : CPU protect Common mib -- FILE NAME: CPUProtect.mib -- DATE : 2012/07/13 -- VERSION : 1.01 -- PURPOSE : To construct the MIB structure of CPU Protect management -- for proprietary enterprise -- ----------------------------------------------------------------------------- -- MODIFICTION HISTORY: -- ----------------------------------------------------------------------------- -- Version, Date, Author -- Description: -- [New Object] -- [Modification] -- Notes: (Requested by who and which project) -- -- Version 1.00, 2012/06/21, Lillian -- This is the first formal version for universal MIB definition. -- -- Version 1.01, 2012/07/13, Lillian -- [Modification] -- 1. Remove the node ˇ°swCPUProtectProtocolRowStatusˇ± -- 2. Modify the access state of ˇ°swCPUProtectProtocolRateˇ± from ˇ°Read-Createˇ± to ˇ°Read-Writeˇ±. -- 3. Modify the description of the node "swCPUProtectProtocolRate". -- ----------------------------------------------------------------------------- CPU-PROTECT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI TruthValue, RowStatus,DisplayString FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF dlink-common-mgmt FROM DLINK-ID-REC-MIB; swCPUProtectMIB MODULE-IDENTITY LAST-UPDATED "201207130000Z" ORGANIZATION "D-Link Corp." CONTACT-INFO " " DESCRIPTION "The MIB module for managing cpu protect engine." ::= { dlink-common-mgmt 106 } swCPUProtectGlobalMgmt OBJECT IDENTIFIER ::= { swCPUProtectMIB 1 } -- ----------------------------------------------------------------------------- -- swCPUProtectGlobalMgmt -- ----------------------------------------------------------------------------- swCPUProtectState OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the CPU Protect state of the switch.Only enabled the feature, the rate limit for packets will be effective." ::= { swCPUProtectGlobalMgmt 1 } -- ----------------------------------------------------------------------------- -- swCPUProtectProtocolTable OBJECT IDENTIFIER ::= { swCPUProtectMIB 2 } -- ----------------------------------------------------------------------------- swCPUProtectProtocolTable OBJECT-TYPE SYNTAX SEQUENCE OF SwCPUProtectProtocolEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that holds the CPU Protected rate limit settings of the device." ::= { swCPUProtectMIB 2} swCPUProtectProtocolEntry OBJECT-TYPE SYNTAX SwCPUProtectProtocolEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of CPU Protected rate limit settings of the device." INDEX { swCPUProtectProtocolType } ::= { swCPUProtectProtocolTable 1 } SwCPUProtectProtocolEntry ::= SEQUENCE { swCPUProtectProtocolType INTEGER, swCPUProtectProtocolRate INTEGER } swCPUProtectProtocolType OBJECT-TYPE SYNTAX INTEGER { arp(1), bpdu(2), icmp(3), igmp(4), snmp(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the CPU Protect Protocol type." ::= { swCPUProtectProtocolEntry 1 } swCPUProtectProtocolRate OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The range for configuring rate-limit in packet per second (pps). A value of -1 means no-limit and all packets of specified type will not be controlled. the default value is no-limit. The rate values are 0 to N. When 0 is set on the specified type, all packets of the specified type will be dropped.The value N means the maximum rate which is project dependent.If the specific packet that sends to the CPU exceeds the above rate,it will be dropped." ::= { swCPUProtectProtocolEntry 2 } END