-- -- WWP-SYSTEM-MIB.my -- -- NOTE WELL -- Starting from LE2X 3.5, the bootp will be replaced by -- the dhcp, hence the object mentioned under wwpSystemBootp -- are deprecated. They have been replaced with -- objects defined in WWP-DHCP-CLIENT-MIB.my . -- Management Applications should no longer be -- examining the objects defined under the wwpSystemBootp -- -- NOTE WELL WWP-SYSTEM-MIB DEFINITIONS ::= BEGIN IMPORTS IpAddress, Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI DisplayString, TruthValue, MacAddress, DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC wwpModules FROM WWP-SMI; wwpSystemMIB MODULE-IDENTITY LAST-UPDATED "200104031700Z" ORGANIZATION "World Wide Packets, Inc" CONTACT-INFO " Mib Meister Postal: World Wide Packets P.O. Box 950 Veradale, WA 99037 USA Phone: +1 509 242 9000 Email: mib.meister@worldwidepackets.com" DESCRIPTION "The MIB module for the WWP System specific information. This MIB provide additional information to whatever is provided by the standard system group." REVISION "200303110000Z" -- 11th March. 2003 DESCRIPTION "The debug group is added." REVISION "200104031700Z" DESCRIPTION "Initial creation." ::= { wwpModules 2 } -- -- Node definitions -- wwpSystemMIBObjects OBJECT IDENTIFIER ::= { wwpSystemMIB 1 } -- System Clock -- wwpSystemClock OBJECT IDENTIFIER ::= { wwpSystemMIBObjects 1 } -- -- System Bootp -- wwpSystemBootp OBJECT IDENTIFIER ::= { wwpSystemMIBObjects 2 } -- -- System Attributes -- wwpSystemAttr OBJECT IDENTIFIER ::= { wwpSystemMIBObjects 3 } -- -- Cfg Group -- wwpSystemCfg OBJECT IDENTIFIER ::= { wwpSystemMIBObjects 4 } -- -- Debug Group -- wwpSystemDebug OBJECT IDENTIFIER ::= { wwpSystemMIBObjects 5 } -- Notifications wwpSystemMIBNotificationPrefix OBJECT IDENTIFIER ::= { wwpSystemMIB 2 } wwpSystemMIBNotifications OBJECT IDENTIFIER ::= { wwpSystemMIBNotificationPrefix 0 } -- Conformance information wwpSystemMIBConformance OBJECT IDENTIFIER ::= { wwpSystemMIB 3 } wwpSystemMIBCompliances OBJECT IDENTIFIER ::= { wwpSystemMIBConformance 1 } wwpSystemMIBGroups OBJECT IDENTIFIER ::= { wwpSystemMIBConformance 2 } wwpSysClockDateTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-write STATUS current DESCRIPTION "The current system date and time of box. There are no privisions for local time or daylight savings. All times use the 24 hr clock and are UTC. Because device time is UTC, only first 7 bytes of DateAndTime data are returned, per rfc1903." ::= { wwpSystemClock 1 } wwpSysClockTimeOffset OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Value used in conjunction with the universal coordinated time (UTC) during the creation of caller ID messages. The value of this object can also be modified by the DHCP using the Time Offset Option." DEFVAL { 0 } ::= { wwpSystemClock 2 } wwpSystemBootpMsgFreq OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) UNITS "in seconds" MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Defines how frequently (in seconds) that bootp messages are sent to the host." DEFVAL { 12 } ::= { wwpSystemBootp 1 } wwpSystemStartMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Base MAC address for the device, from which all other mac addresses are derived." ::= { wwpSystemAttr 1 } wwpSystemDefaultGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Default gateway IP address." ::= { wwpSystemAttr 2 } wwpSystemTftpServer OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Has the TFTP Server host name assigned by the bootp server, and later used for subsequent bootp requests." ::= { wwpSystemAttr 3 } wwpSystemBootFile OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Name of the dhcp cmd file for the system." ::= { wwpSystemAttr 4 } wwpSystemInterfaceHostName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Host name for vmi or smi interface." ::= { wwpSystemAttr 5 } wwpSystemCfgControl OBJECT-TYPE SYNTAX INTEGER { none(0), save(1), updatePasswords(2), updateSnmpCfg(3), mfgDefaultCfg(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls configuration options on the device. The current options are: save: to make the configuration changes made using SNMP persistent across a reboot. updatePasswords: to update the current password file with the new password file. The new passwords will become active immediately. updateSnmpCfg: to update the current snmp configuration data. The new configuration will become active immediately. mfgDefaultCfg: Set system configuration to factory defaults. Note: this will wipe out all of the current configuration including Password and VLAN information. If the system doesn't support any of these control configuration option, it should return error while trying to set this object to the specific option. A read on this object should return none(0)." ::= { wwpSystemCfg 1 } wwpSystemCfgFilepath OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the path for configuration related files." ::= { wwpSystemCfg 2 } wwpSystemConsolePortEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to 'true' will enable the console port." DEFVAL { false } ::= { wwpSystemDebug 1 } END -- -- WWP-SYSTEM-MIB.my --