ATMEDIA-MIB DEFINITIONS ::= BEGIN -- -- MIB definied by ATMedia GmbH -- for use with ATMedia Encryptors -- (c) 2002-2007 ATMedia GmbH -- IMPORTS OBJECT-TYPE, TimeTicks, Counter32, Gauge32, Counter64, enterprises FROM SNMPv2-SMI DateAndTime FROM SNMPv2-TC; DisplayString ::= OCTET STRING atmedia OBJECT IDENTIFIER ::= { enterprises 13458 } atmcrypt OBJECT IDENTIFIER ::= { atmedia 1 } acMachine OBJECT IDENTIFIER ::= { atmcrypt 1 } acSoftware OBJECT IDENTIFIER ::= { atmcrypt 2 } acHardware OBJECT IDENTIFIER ::= { atmcrypt 3 } acStatus OBJECT IDENTIFIER ::= { atmcrypt 4 } acMaintenance OBJECT IDENTIFIER ::= { atmcrypt 5 } acTransmission OBJECT IDENTIFIER ::= { atmcrypt 6 } acInterfaces OBJECT IDENTIFIER ::= { acHardware 3 } acEncryptors OBJECT IDENTIFIER ::= { acHardware 4 } acInterfaceStatus OBJECT IDENTIFIER ::= { acStatus 1 } acEncryptorStatus OBJECT IDENTIFIER ::= { acStatus 2 } -- media dependend status / alarm counter acSonet OBJECT IDENTIFIER ::= { acTransmission 1 } acE3 OBJECT IDENTIFIER ::= { acTransmission 2 } acE1 OBJECT IDENTIFIER ::= { acTransmission 3 } acGigabit OBJECT IDENTIFIER ::= { acTransmission 4 } acFibrechannel OBJECT IDENTIFIER ::= { acTransmission 5 } acSonetStatus OBJECT IDENTIFIER ::= { acSonet 1 } acSonetAlarms OBJECT IDENTIFIER ::= { acSonet 2 } acSonetErrCounter OBJECT IDENTIFIER ::= { acSonet 3 } acSonetEtsCounter OBJECT IDENTIFIER ::= { acSonet 4 } acE3Status OBJECT IDENTIFIER ::= { acE3 1 } acE3Alarms OBJECT IDENTIFIER ::= { acE3 2 } acE3ErrCounter OBJECT IDENTIFIER ::= { acE3 3 } acE3EtsCounter OBJECT IDENTIFIER ::= { acE3 4 } acE1Status OBJECT IDENTIFIER ::= { acE1 1 } acE1Alarms OBJECT IDENTIFIER ::= { acE1 2 } acE1ErrCounter OBJECT IDENTIFIER ::= { acE1 3 } acE1EtsCounter OBJECT IDENTIFIER ::= { acE1 4 } acGigabitStatus OBJECT IDENTIFIER ::= { acGigabit 1 } acGigabitAlarms OBJECT IDENTIFIER ::= { acGigabit 2 } acGigabitErrCounter OBJECT IDENTIFIER ::= { acGigabit 3 } acGigabitEtsCounter OBJECT IDENTIFIER ::= { acGigabit 4 } acFibrechannelStatus OBJECT IDENTIFIER ::= { acFibrechannel 1 } acFibrechannelAlarms OBJECT IDENTIFIER ::= { acFibrechannel 2 } acFibrechannelErrCounter OBJECT IDENTIFIER ::= { acFibrechannel 3 } acFibrechannelEtsCounter OBJECT IDENTIFIER ::= { acFibrechannel 4 } -- -- acMachine part -- acProductID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The product identifier of the ATMedia Encryptor device." ::= { acMachine 1 } acSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of the ATMedia Encryptor device." ::= { acMachine 2 } acHostname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The actual host name of the ATMedia Encryptor device." ::= { acMachine 3 } acContact OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The contact person for ATMedia Encryptor administration." ::= { acMachine 4 } acLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The location of the ATMedia Encryptor device." ::= { acMachine 5 } acDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The description of the ATMedia Encryptor device." ::= { acMachine 6 } -- -- acSoftware part -- acSoftVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The software version running on the ATMedia Encryptor device." ::= { acSoftware 1 } acSoftDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the ATMedia Encryptor software." ::= { acSoftware 2 } -- -- acHardware part -- acHardVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The hardware version of the ATMedia Encryptor device." ::= { acHardware 1 } acHardDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the ATMedia Encryptor hardware." ::= { acHardware 2 } -- -- acInterfaces part -- acIfNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical ATMedia Encryptor interfaces." ::= { acInterfaces 1 } acIfTable OBJECT-TYPE SYNTAX SEQUENCE OF AcIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of physical ATMedia Encryptor interfaces. The number of entries is given by the value of acsIfNumber." ::= { acInterfaces 2 } acIfEntry OBJECT-TYPE SYNTAX AcIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular physical interface." INDEX { acIfIndex } ::= { acIfTable 1 } AcIfEntry ::= SEQUENCE { acIfIndex INTEGER, acIfDescr DisplayString, acIfPhyType INTEGER, acIfSpeed Gauge32, acIfRevision DisplayString } acIfIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acIfEntry 1 } acIfDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the physical interface." ::= { acIfEntry 2 } acIfPhyType OBJECT-TYPE SYNTAX INTEGER { other(0), -- none of the following sonet(1), -- SONET/SDH standard e3(2), -- PDH standard E3 ds3(3), -- PDH standard DS3 e1(4), -- E1 standard ds1(5), -- DS1/T1 standard gigabit(6), -- 1000Base-X (IEEE 802.3z) sonetlink(7), -- SONET/SDH link fibrechannel(8), -- Fibrechannel ethernet(9) -- Ethernet 10/100 } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the physical interface." ::= { acIfEntry 3 } acIfSpeed OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Speed of the physical interface in bps." ::= { acIfEntry 4 } acIfRevision OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Revision of the physical interface." ::= { acIfEntry 5 } -- -- acEncryptors part -- acEcNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ATMedia encryptor engines." ::= { acEncryptors 1 } acEcTable OBJECT-TYPE SYNTAX SEQUENCE OF AcEcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ATMedia encryptor engines. The number of entries is given by the value of acsEcNumber." ::= { acEncryptors 2 } acEcEntry OBJECT-TYPE SYNTAX AcEcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular encryptor engine." INDEX { acEcIndex } ::= { acEcTable 1 } AcEcEntry ::= SEQUENCE { acEcIndex INTEGER, acEcDescr DisplayString, acEcRevision DisplayString } acEcIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each encryptor engine. It is recommended that values are assigned contiguously starting from 1. The value for each encryptor must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acEcEntry 1 } acEcDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the encryptor engine." ::= { acEcEntry 2 } acEcRevision OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Revision of the encryptor engine." ::= { acEcEntry 3 } -- -- acInterfaceStatus part -- acInterfaceStatusNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ATMedia Encryptor physical interfaces." ::= { acInterfaceStatus 1 } acInterfaceStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AcInterfaceStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of interface cell counter informations. The number of entries is given by the value of acInferfaceStatusNumber." ::= { acInterfaceStatus 2 } acInterfaceStatusEntry OBJECT-TYPE SYNTAX AcInterfaceStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing alarm informations applicable to a particular physical interface." INDEX { acInterfaceStatusIndex } ::= { acInterfaceStatusTable 1 } AcInterfaceStatusEntry ::= SEQUENCE { acInterfaceStatusIndex INTEGER, acInterfaceStatusState INTEGER, acInterfaceStatusLastChange TimeTicks, acInterfaceStatusDescr DisplayString, acInterfaceStatusRxCells Counter64, acInterfaceStatusTxCells Counter64, acInterfaceStatusRxBytes Counter64, acInterfaceStatusTxBytes Counter64, acInterfaceStatusRxRate Gauge32, acInterfaceStatusTxRate Gauge32 } acInterfaceStatusIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acInterfaceStatusEntry 1 } acInterfaceStatusState OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational state of the interface." ::= { acInterfaceStatusEntry 2 } acInterfaceStatusLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the interface entered its current operational state." ::= { acInterfaceStatusEntry 3 } acInterfaceStatusDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the encryptor engine status." ::= { acInterfaceStatusEntry 4 } acInterfaceStatusRxCells OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of cells received by the physical interface." ::= { acInterfaceStatusEntry 5 } acInterfaceStatusTxCells OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of cells sent by the physical interface." ::= { acInterfaceStatusEntry 6 } acInterfaceStatusRxBytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of bytes received by the physical interface." ::= { acInterfaceStatusEntry 7 } acInterfaceStatusTxBytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of bytes sent by the physical interface." ::= { acInterfaceStatusEntry 8 } acInterfaceStatusRxRate OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Data rate with which cells are received by the physical interface." ::= { acInterfaceStatusEntry 9 } acInterfaceStatusTxRate OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Data rate with which cells are sent by the physical interface." ::= { acInterfaceStatusEntry 10 } -- -- acEncryptors part -- acEncryptorStatusNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ATMedia encryptor engines." ::= { acEncryptorStatus 1 } acEncryptorStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AcEncryptorStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ATMedia encryptor engine status informations. The number of entries is given by the value of acsEcstatNumber." ::= { acEncryptorStatus 2 } acEncryptorStatusEntry OBJECT-TYPE SYNTAX AcEncryptorStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing status information applicable to a particular encryptor engine." INDEX { acEncryptorStatusIndex } ::= { acEncryptorStatusTable 1 } AcEncryptorStatusEntry ::= SEQUENCE { acEncryptorStatusIndex INTEGER, acEncryptorStatusState INTEGER, acEncryptorStatusLastChange TimeTicks, acEncryptorStatusDescr DisplayString } acEncryptorStatusIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each encryptor engine. It is recommended that values are assigned contiguously starting from 1. The value for each encryptor must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acEncryptorStatusEntry 1 } acEncryptorStatusState OBJECT-TYPE SYNTAX INTEGER { up(1), -- encryptor running down(2), -- encryptor stopped plain(3) -- plaintext (version 2.1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the encryptor engine. Since version 2.1 all encryptors will distinguish between crypt (running) and plaintext mode" ::= { acEncryptorStatusEntry 2 } acEncryptorStatusLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the encryptor entered its current operational state." ::= { acEncryptorStatusEntry 3 } acEncryptorStatusDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the encryptor engine status." ::= { acEncryptorStatusEntry 4 } -- -- acMaintenance part -- acMaUptime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Hundredth of seconds since system start." ::= { acMaintenance 1 } acMaLastBoot OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Hundredth of seconds since last reboot." ::= { acMaintenance 2 } acMaSystime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "System Date/Time of ATMedia Encryptor device (UTC)." ::= { acMaintenance 3 } acMaTemperature OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of ATMedia Encryptor device in hundredth of degree celsius." ::= { acMaintenance 4 } acMaCpuTemperature1 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of the first CPU of the ATMedia Encryptor device in hundredth of degree celsius." ::= { acMaintenance 5 } acMaCpuTemperature2 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of the second CPU of the ATMedia Encryptor device in hundredth of degree celsius." ::= { acMaintenance 6 } acMaFanSpeed1 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Speed of the first fan of the ATMedia Encryptor device in rpm (revolutions per minute)" ::= { acMaintenance 7 } acMaFanSpeed2 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Speed of the second fan of the ATMedia Encryptor device in rpm (revolutions per minute)" ::= { acMaintenance 8 } acMaFanSpeed3 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Speed of the third fan of the ATMedia Encryptor device in rpm (revolutions per minute)" ::= { acMaintenance 9 } acMaFanSpeed4 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Speed of the fourth fan of the ATMedia Encryptor device in rpm (revolutions per minute)" ::= { acMaintenance 10 } acMaPowerState OBJECT-TYPE SYNTAX INTEGER { unknown(0), -- unknown state up(1), -- power supply ok down(2) -- power failure detected } MAX-ACCESS read-only STATUS current DESCRIPTION "State of the power supply of the ATMedia Encryptor device" ::= { acMaintenance 11 } acMaPowerLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the power supply entered its current state." ::= { acMaintenance 12 } -- -- acSonetStatus part -- acSonetStatusNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical Sonet interfaces." ::= { acSonetStatus 1 } acSonetStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSonetStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of physical Sonet interface status informations. The number of entries is given by the value of acsIfstatNumber." ::= { acSonetStatus 2 } acSonetStatusEntry OBJECT-TYPE SYNTAX AcSonetStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing status information applicable to a particular Sonet physical interface." INDEX { acSonetStatusIndex } ::= { acSonetStatusTable 1 } AcSonetStatusEntry ::= SEQUENCE { acSonetStatusIndex INTEGER, acSonetStatusState INTEGER, acSonetStatusLOS INTEGER, acSonetStatusOOF INTEGER, acSonetStatusLOC INTEGER, acSonetStatusLineAIS INTEGER, acSonetStatusLineRDI INTEGER, acSonetStatusPathAIS INTEGER, acSonetStatusPathYellow INTEGER, acSonetStatusCustom INTEGER, acSonetStatusDescr DisplayString } acSonetStatusIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acSonetStatusEntry 1 } acSonetStatusState OBJECT-TYPE SYNTAX INTEGER { up(1), -- interface running down(2), -- interface not running failure(3) -- some error detected } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the physical Sonet interface." ::= { acSonetStatusEntry 2 } acSonetStatusLOS OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type LOS at the physical Sonet interface." ::= { acSonetStatusEntry 3 } acSonetStatusOOF OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type OOF at the physical Sonet interface." ::= { acSonetStatusEntry 4 } acSonetStatusLOC OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type LOC at the physical Sonet interface." ::= { acSonetStatusEntry 5 } acSonetStatusLineAIS OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type LineAIS at the physical Sonet interface." ::= { acSonetStatusEntry 6 } acSonetStatusLineRDI OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type LineRDI at the physical Sonet interface." ::= { acSonetStatusEntry 7 } acSonetStatusPathAIS OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type PathAIS at the physical Sonet interface." ::= { acSonetStatusEntry 8 } acSonetStatusPathYellow OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type PathYellow at the physical Sonet interface." ::= { acSonetStatusEntry 9 } acSonetStatusCustom OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Numerical status information of the physical Sonet interface. The AcSonetStatusCustom is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The various bit positions are: 0x0001 STATUS_LOS 0x0002 STATUS_LOP 0x0004 STATUS_LINE_AIS 0x0008 STATUS_PATH_AIS 0x0010 STATUS_PATH_YELLOW 0x0020 STATUS_STS_OOF 0x0040 STATUS_STS_LOF 0x0080 STATUS_STS_LOF23 0x0100 STATUS_LOC 0x0200 STATUS_LINE_FERF 0x1000 STATUS_PATH_FERF" ::= { acSonetStatusEntry 10 } acSonetStatusDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the status of the physical Sonet interface." ::= { acSonetStatusEntry 11 } -- -- acSonetAlarms part -- acSonetAlarmsNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical Sonet interfaces." ::= { acSonetAlarms 1 } acSonetAlarmsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSonetAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Sonet interface alarm informations. The number of entries is given by the value of acSonetAlarmsNumber." ::= { acSonetAlarms 2 } acSonetAlarmsEntry OBJECT-TYPE SYNTAX AcSonetAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing alarm informations applicable to a particular physical Sonet interface." INDEX { acSonetAlarmsIndex } ::= { acSonetAlarmsTable 1 } AcSonetAlarmsEntry ::= SEQUENCE { acSonetAlarmsIndex INTEGER, acSonetAlarmsLOS Counter64, acSonetAlarmsLineAIS Counter64, acSonetAlarmsLineRDI Counter64, acSonetAlarmsPathAIS Counter64, acSonetAlarmsPathYellow Counter64 } acSonetAlarmsIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acSonetAlarmsEntry 1 } acSonetAlarmsLOS OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alarm conditions of type LOS at the physical interface." ::= { acSonetAlarmsEntry 2 } acSonetAlarmsLineAIS OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alarm conditions of type LineAIS at the physical interface." ::= { acSonetAlarmsEntry 3 } acSonetAlarmsLineRDI OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alarm conditions of type LineRDI at the physical interface." ::= { acSonetAlarmsEntry 4 } acSonetAlarmsPathAIS OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alarm conditions of type PathAIS at the physical interface." ::= { acSonetAlarmsEntry 5 } acSonetAlarmsPathYellow OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alarm conditions of type PathYellow at the physical interface." ::= { acSonetAlarmsEntry 6 } -- -- acSonetErrCounter part -- acSonetErrCounterNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical Sonet interfaces." ::= { acSonetErrCounter 1 } acSonetErrCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSonetErrCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Sonet interface alarm informations. The number of entries is given by the value of acSonetErrCounterNumber." ::= { acSonetErrCounter 2 } acSonetErrCounterEntry OBJECT-TYPE SYNTAX AcSonetErrCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing alarm informations applicable to a particular physical Sonet interface." INDEX { acSonetErrCounterIndex } ::= { acSonetErrCounterTable 1 } AcSonetErrCounterEntry ::= SEQUENCE { acSonetErrCounterIndex INTEGER, acSonetErrCounterOOF Counter64, acSonetErrCounterLOC Counter64, acSonetErrCounterB1BIP Counter64, acSonetErrCounterB2BIP Counter64, acSonetErrCounterB3BIP Counter64, acSonetErrCounterLineFEBE Counter64, acSonetErrCounterPathFEBE Counter64, acSonetErrCounterHEC Counter64 } acSonetErrCounterIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acSonetErrCounterEntry 1 } acSonetErrCounterOOF OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type OOF at the physical interface." ::= { acSonetErrCounterEntry 2 } acSonetErrCounterLOC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LOC at the physical interface." ::= { acSonetErrCounterEntry 3 } acSonetErrCounterB1BIP OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type B1BIP at the physical interface." ::= { acSonetErrCounterEntry 4 } acSonetErrCounterB2BIP OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type B2BIP at the physical interface." ::= { acSonetErrCounterEntry 5 } acSonetErrCounterB3BIP OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type B3BIP at the physical interface." ::= { acSonetErrCounterEntry 6 } acSonetErrCounterLineFEBE OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LineFEBE at the physical interface." ::= { acSonetErrCounterEntry 7 } acSonetErrCounterPathFEBE OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type PathFEBE at the physical interface." ::= { acSonetErrCounterEntry 8 } acSonetErrCounterHEC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type HEC at the physical interface." ::= { acSonetErrCounterEntry 9 } -- -- acSonetEtsCounter part -- acSonetEtsCounterNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical Sonet interfaces." ::= { acSonetEtsCounter 1 } acSonetEtsCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSonetEtsCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Sonet interface alarm informations. The number of entries is given by the value of acSonetEtsCounterNumber." ::= { acSonetEtsCounter 2 } acSonetEtsCounterEntry OBJECT-TYPE SYNTAX AcSonetEtsCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing alarm informations applicable to a particular physical Sonet interface." INDEX { acSonetEtsCounterIndex } ::= { acSonetEtsCounterTable 1 } AcSonetEtsCounterEntry ::= SEQUENCE { acSonetEtsCounterIndex INTEGER, acSonetEtsCounterOOF Counter64, acSonetEtsCounterLOC Counter64, acSonetEtsCounterB1BIP Counter64, acSonetEtsCounterB2BIP Counter64, acSonetEtsCounterB3BIP Counter64, acSonetEtsCounterLineFEBE Counter64, acSonetEtsCounterPathFEBE Counter64, acSonetEtsCounterHEC Counter64 } acSonetEtsCounterIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acSonetEtsCounterEntry 1 } acSonetEtsCounterOOF OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type OOF at the physical interface." ::= { acSonetEtsCounterEntry 2 } acSonetEtsCounterLOC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LOC at the physical interface." ::= { acSonetEtsCounterEntry 3 } acSonetEtsCounterB1BIP OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type B1BIP at the physical interface." ::= { acSonetEtsCounterEntry 4 } acSonetEtsCounterB2BIP OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type B2BIP at the physical interface." ::= { acSonetEtsCounterEntry 5 } acSonetEtsCounterB3BIP OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type B3BIP at the physical interface." ::= { acSonetEtsCounterEntry 6 } acSonetEtsCounterLineFEBE OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LineFEBE at the physical interface." ::= { acSonetEtsCounterEntry 7 } acSonetEtsCounterPathFEBE OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type PathFEBE at the physical interface." ::= { acSonetEtsCounterEntry 8 } acSonetEtsCounterHEC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type HEC at the physical interface." ::= { acSonetEtsCounterEntry 9 } -- -- acE3Status part -- acE3StatusNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical E3 interfaces." ::= { acE3Status 1 } acE3StatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AcE3StatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of physical E3 interface status informations. The number of entries is given by the value of acE3StatusNumber." ::= { acE3Status 2 } acE3StatusEntry OBJECT-TYPE SYNTAX AcE3StatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing status information applicable to a particular E3 physical interface." INDEX { acE3StatusIndex } ::= { acE3StatusTable 1 } AcE3StatusEntry ::= SEQUENCE { acE3StatusIndex INTEGER, acE3StatusState INTEGER, acE3StatusLOS INTEGER, acE3StatusOOF INTEGER, acE3StatusLOC INTEGER, acE3StatusAIS INTEGER, acE3StatusMAFERF INTEGER, acE3StatusCustom INTEGER, acE3StatusDescr DisplayString } acE3StatusIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acE3StatusEntry 1 } acE3StatusState OBJECT-TYPE SYNTAX INTEGER { up(1), -- interface running down(2), -- interface not running failure(3) -- some error detected } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the physical E3 interface." ::= { acE3StatusEntry 2 } acE3StatusLOS OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type LOS at the physical E3 interface." ::= { acE3StatusEntry 3 } acE3StatusOOF OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type OOF at the physical E3 interface." ::= { acE3StatusEntry 4 } acE3StatusLOC OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type LOC at the physical E3 interface." ::= { acE3StatusEntry 5 } acE3StatusAIS OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type AIS at the physical E3 interface." ::= { acE3StatusEntry 6 } acE3StatusMAFERF OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type MAFERF at the physical E3 interface." ::= { acE3StatusEntry 7 } acE3StatusCustom OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Numerical status information of the physical E3 interface. The AcE3StatusCustom is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The various bit positions are: 0x0001 STATUS_LOS 0x0004 STATUS_E3_AIS 0x0020 STATUS_E3_OOF 0x0040 STATUS_E3_LOF 0x0080 STATUS_E3_LOF23 0x0100 STATUS_LOC 0x1000 STATUS_MA_FERF" ::= { acE3StatusEntry 8 } acE3StatusDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the status of the physical E3 interface." ::= { acE3StatusEntry 9 } -- -- acE3Alarms part -- acE3AlarmsNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical E3 interfaces." ::= { acE3Alarms 1 } acE3AlarmsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcE3AlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of E3 interface alarm informations. The number of entries is given by the value of acE3AlarmsNumber." ::= { acE3Alarms 2 } acE3AlarmsEntry OBJECT-TYPE SYNTAX AcE3AlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing alarm informations applicable to a particular physical E3 interface." INDEX { acE3AlarmsIndex } ::= { acE3AlarmsTable 1 } AcE3AlarmsEntry ::= SEQUENCE { acE3AlarmsIndex INTEGER, acE3AlarmsLOS Counter64, acE3AlarmsAIS Counter64, acE3AlarmsMAFERF Counter64 } acE3AlarmsIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acE3AlarmsEntry 1 } acE3AlarmsLOS OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alarm conditions of type LOS at the physical interface." ::= { acE3AlarmsEntry 2 } acE3AlarmsAIS OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alarm conditions of type AIS at the physical interface." ::= { acE3AlarmsEntry 3 } acE3AlarmsMAFERF OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alarm conditions of type MAFERF at the physical interface." ::= { acE3AlarmsEntry 4 } -- -- acE3ErrCounter part -- acE3ErrCounterNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical E3 interfaces." ::= { acE3ErrCounter 1 } acE3ErrCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF AcE3ErrCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of E3 interface alarm informations. The number of entries is given by the value of acE3ErrCounterNumber." ::= { acE3ErrCounter 2 } acE3ErrCounterEntry OBJECT-TYPE SYNTAX AcE3ErrCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing alarm informations applicable to a particular physical E3 interface." INDEX { acE3ErrCounterIndex } ::= { acE3ErrCounterTable 1 } AcE3ErrCounterEntry ::= SEQUENCE { acE3ErrCounterIndex INTEGER, acE3ErrCounterLCV Counter64, acE3ErrCounterOOF Counter64, acE3ErrCounterLOC Counter64, acE3ErrCounterBIP Counter64, acE3ErrCounterMAFEBE Counter64, acE3ErrCounterHEC Counter64 } acE3ErrCounterIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acE3ErrCounterEntry 1 } acE3ErrCounterLCV OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LCV at the physical interface." ::= { acE3ErrCounterEntry 2 } acE3ErrCounterOOF OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type OOF at the physical interface." ::= { acE3ErrCounterEntry 3 } acE3ErrCounterLOC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LOC at the physical interface." ::= { acE3ErrCounterEntry 4 } acE3ErrCounterBIP OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type B1BIP at the physical interface." ::= { acE3ErrCounterEntry 5 } acE3ErrCounterMAFEBE OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type MAFEBE at the physical interface." ::= { acE3ErrCounterEntry 6 } acE3ErrCounterHEC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type HEC at the physical interface." ::= { acE3ErrCounterEntry 7 } -- -- acE3EtsCounter part -- acE3EtsCounterNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical E3 interfaces." ::= { acE3EtsCounter 1 } acE3EtsCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF AcE3EtsCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of E3 interface alarm informations. The number of entries is given by the value of acE3EtsCounterNumber." ::= { acE3EtsCounter 2 } acE3EtsCounterEntry OBJECT-TYPE SYNTAX AcE3EtsCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing alarm informations applicable to a particular physical E3 interface." INDEX { acE3EtsCounterIndex } ::= { acE3EtsCounterTable 1 } AcE3EtsCounterEntry ::= SEQUENCE { acE3EtsCounterIndex INTEGER, acE3EtsCounterLCV Counter64, acE3EtsCounterOOF Counter64, acE3EtsCounterLOC Counter64, acE3EtsCounterBIP Counter64, acE3EtsCounterMAFEBE Counter64, acE3EtsCounterHEC Counter64 } acE3EtsCounterIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acE3EtsCounterEntry 1 } acE3EtsCounterLCV OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LCV at the physical interface." ::= { acE3EtsCounterEntry 2 } acE3EtsCounterOOF OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type OOF at the physical interface." ::= { acE3EtsCounterEntry 3 } acE3EtsCounterLOC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LOC at the physical interface." ::= { acE3EtsCounterEntry 4 } acE3EtsCounterBIP OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type B1BIP at the physical interface." ::= { acE3EtsCounterEntry 5 } acE3EtsCounterMAFEBE OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type MAFEBE at the physical interface." ::= { acE3EtsCounterEntry 6 } acE3EtsCounterHEC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type HEC at the physical interface." ::= { acE3EtsCounterEntry 7 } -- -- acGigabitStatus part -- acGigabitStatusNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical Gigabit interfaces." ::= { acGigabitStatus 1 } acGigabitStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AcGigabitStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of physical Gigabit interface status informations. The number of entries is given by the value of acsGigabitStatusNumber." ::= { acGigabitStatus 2 } acGigabitStatusEntry OBJECT-TYPE SYNTAX AcGigabitStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing status information applicable to a particular Gigabit physical interface." INDEX { acGigabitStatusIndex } ::= { acGigabitStatusTable 1 } -- TODO AcGigabitStatusEntry ::= SEQUENCE { acGigabitStatusIndex INTEGER, acGigabitStatusState INTEGER, acGigabitStatusLOS INTEGER, acGigabitStatusLossofSync INTEGER, acGigabitStatusLinkDown INTEGER, acGigabitStatusCustom INTEGER, acGigabitStatusDescr DisplayString } acGigabitStatusIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acGigabitStatusEntry 1 } acGigabitStatusState OBJECT-TYPE SYNTAX INTEGER { up(1), -- interface running down(2), -- interface not running failure(3) -- some error detected } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the physical Gigabit interface." ::= { acGigabitStatusEntry 2 } acGigabitStatusLOS OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type LOS at the physical Gigabit interface." ::= { acGigabitStatusEntry 3 } acGigabitStatusLossofSync OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type LossofSync at the physical Gigabit interface." ::= { acGigabitStatusEntry 4 } acGigabitStatusLinkDown OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type LinkDown at the physical Gigabit interface." ::= { acGigabitStatusEntry 5 } acGigabitStatusCustom OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Numerical status information of the physical Gigabit interface. The AcSonetStatusCustom is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The various bit positions are: 0x0001 STATUS_LOS 0x0002 STATUS_LossofSync 0x0004 STATUS_LinkDown" ::= { acGigabitStatusEntry 6 } acGigabitStatusDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the status of the physical Gigabit interface." ::= { acGigabitStatusEntry 7 } -- -- acGigabitAlarms part -- acGigabitAlarmsNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical Gigabit interfaces." ::= { acGigabitAlarms 1 } acGigabitAlarmsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcGigabitAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Gigabit interface alarm informations. The number of entries is given by the value of acGigabitAlarmsNumber." ::= { acGigabitAlarms 2 } acGigabitAlarmsEntry OBJECT-TYPE SYNTAX AcGigabitAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing alarm informations applicable to a particular physical Gigabit interface." INDEX { acGigabitAlarmsIndex } ::= { acGigabitAlarmsTable 1 } AcGigabitAlarmsEntry ::= SEQUENCE { acGigabitAlarmsIndex INTEGER, acGigabitAlarmsLOS Counter64, acGigabitAlarmsLinkDown Counter64 } acGigabitAlarmsIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acGigabitAlarmsEntry 1 } acGigabitAlarmsLOS OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alarm conditions of type LOS at the physical interface." ::= { acGigabitAlarmsEntry 2 } acGigabitAlarmsLinkDown OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alarm conditions of type LinkDown at the physical interface." ::= { acGigabitAlarmsEntry 3 } -- -- acGigabitErrCounter part -- acGigabitErrCounterNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical Gigabit interfaces." ::= { acGigabitErrCounter 1 } acGigabitErrCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF AcGigabitErrCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Gigabit interface alarm informations. The number of entries is given by the value of acGigabitErrCounterNumber." ::= { acGigabitErrCounter 2 } acGigabitErrCounterEntry OBJECT-TYPE SYNTAX AcGigabitErrCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing alarm informations applicable to a particular physical Gigabit interface." INDEX { acGigabitErrCounterIndex } ::= { acGigabitErrCounterTable 1 } AcGigabitErrCounterEntry ::= SEQUENCE { acGigabitErrCounterIndex INTEGER, acGigabitErrCounterTotalFrame Counter64, acGigabitErrCounterErroredFrame Counter64, acGigabitErrCounterFalseCarrier Counter64, acGigabitErrCounterLossofSync Counter64, acGigabitErrCounterLineError Counter64 } acGigabitErrCounterIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acGigabitErrCounterEntry 1 } acGigabitErrCounterTotalFrame OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of total frames at the physical interface." ::= { acGigabitErrCounterEntry 2 } acGigabitErrCounterErroredFrame OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of errored frames at the physical interface." ::= { acGigabitErrCounterEntry 3 } acGigabitErrCounterFalseCarrier OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type FalseCarrier at the physical interface." ::= { acGigabitErrCounterEntry 4 } acGigabitErrCounterLossofSync OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LossofSync at the physical interface." ::= { acGigabitErrCounterEntry 5 } acGigabitErrCounterLineError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LineError at the physical interface." ::= { acGigabitErrCounterEntry 6 } -- -- acGigabitEtsCounter part -- acGigabitEtsCounterNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical Gigabit interfaces." ::= { acGigabitEtsCounter 1 } acGigabitEtsCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF AcGigabitEtsCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Gigabit interface alarm informations. The number of entries is given by the value of acGigabitEtsCounterNumber." ::= { acGigabitEtsCounter 2 } acGigabitEtsCounterEntry OBJECT-TYPE SYNTAX AcGigabitEtsCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing alarm informations applicable to a particular physical Gigabit interface." INDEX { acGigabitEtsCounterIndex } ::= { acGigabitEtsCounterTable 1 } AcGigabitEtsCounterEntry ::= SEQUENCE { acGigabitEtsCounterIndex INTEGER, acGigabitEtsCounterTotalFrame Counter64, acGigabitEtsCounterErroredFrame Counter64, acGigabitEtsCounterFalseCarrier Counter64, acGigabitEtsCounterLossofSync Counter64, acGigabitEtsCounterLineError Counter64 } acGigabitEtsCounterIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acGigabitEtsCounterEntry 1 } acGigabitEtsCounterTotalFrame OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "not defined." ::= { acGigabitEtsCounterEntry 2 } acGigabitEtsCounterErroredFrame OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of errored frames at the physical interface." ::= { acGigabitEtsCounterEntry 3 } acGigabitEtsCounterFalseCarrier OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type FalseCarrier at the physical interface." ::= { acGigabitEtsCounterEntry 4 } acGigabitEtsCounterLossofSync OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LossofSync at the physical interface." ::= { acGigabitEtsCounterEntry 5 } acGigabitEtsCounterLineError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LineError at the physical interface." ::= { acGigabitEtsCounterEntry 6 } -- -- acFibrechannelStatus part -- acFibrechannelStatusNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical Fibrechannel interfaces." ::= { acFibrechannelStatus 1 } acFibrechannelStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AcFibrechannelStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of physical Fibrechannel interface status informations. The number of entries is given by the value of acsFibrechannelStatusNumber." ::= { acFibrechannelStatus 2 } acFibrechannelStatusEntry OBJECT-TYPE SYNTAX AcFibrechannelStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing status information applicable to a particular Fibrechannel physical interface." INDEX { acFibrechannelStatusIndex } ::= { acFibrechannelStatusTable 1 } -- TODO AcFibrechannelStatusEntry ::= SEQUENCE { acFibrechannelStatusIndex INTEGER, acFibrechannelStatusState INTEGER, acFibrechannelStatusLOS INTEGER, acFibrechannelStatusLossofSync INTEGER, acFibrechannelStatusLinkDown INTEGER, acFibrechannelStatusCustom INTEGER, acFibrechannelStatusDescr DisplayString } acFibrechannelStatusIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acFibrechannelStatusEntry 1 } acFibrechannelStatusState OBJECT-TYPE SYNTAX INTEGER { up(1), -- interface running down(2), -- interface not running failure(3) -- some error detected } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the physical Fibrechannel interface." ::= { acFibrechannelStatusEntry 2 } acFibrechannelStatusLOS OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type LOS at the physical Fibrechannel interface." ::= { acFibrechannelStatusEntry 3 } acFibrechannelStatusLossofSync OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type LossofSync at the physical Fibrechannel interface." ::= { acFibrechannelStatusEntry 4 } acFibrechannelStatusLinkDown OBJECT-TYPE SYNTAX INTEGER { active(1), -- alarm set inactive(2) -- alarm not set } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition of type LinkDown at the physical Fibrechannel interface." ::= { acFibrechannelStatusEntry 5 } acFibrechannelStatusCustom OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Numerical status information of the physical Fibrechannel interface. The AcSonetStatusCustom is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The various bit positions are: 0x0001 STATUS_LOS 0x0002 STATUS_LossofSync 0x0004 STATUS_LinkDown" ::= { acFibrechannelStatusEntry 6 } acFibrechannelStatusDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the status of the physical Fibrechannel interface." ::= { acFibrechannelStatusEntry 7 } -- -- acFibrechannelAlarms part -- acFibrechannelAlarmsNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical Fibrechannel interfaces." ::= { acFibrechannelAlarms 1 } acFibrechannelAlarmsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcFibrechannelAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Fibrechannel interface alarm informations. The number of entries is given by the value of acFibrechannelAlarmsNumber." ::= { acFibrechannelAlarms 2 } acFibrechannelAlarmsEntry OBJECT-TYPE SYNTAX AcFibrechannelAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing alarm informations applicable to a particular physical Fibrechannel interface." INDEX { acFibrechannelAlarmsIndex } ::= { acFibrechannelAlarmsTable 1 } AcFibrechannelAlarmsEntry ::= SEQUENCE { acFibrechannelAlarmsIndex INTEGER, acFibrechannelAlarmsLOS Counter64, acFibrechannelAlarmsLinkDown Counter64 } acFibrechannelAlarmsIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acFibrechannelAlarmsEntry 1 } acFibrechannelAlarmsLOS OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alarm conditions of type LOS at the physical interface." ::= { acFibrechannelAlarmsEntry 2 } acFibrechannelAlarmsLinkDown OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alarm conditions of type LinkDown at the physical interface." ::= { acFibrechannelAlarmsEntry 3 } -- -- acFibrechannelErrCounter part -- acFibrechannelErrCounterNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical Fibrechannel interfaces." ::= { acFibrechannelErrCounter 1 } acFibrechannelErrCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF AcFibrechannelErrCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Fibrechannel interface alarm informations. The number of entries is given by the value of acFibrechannelErrCounterNumber." ::= { acFibrechannelErrCounter 2 } acFibrechannelErrCounterEntry OBJECT-TYPE SYNTAX AcFibrechannelErrCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing alarm informations applicable to a particular physical Fibrechannel interface." INDEX { acFibrechannelErrCounterIndex } ::= { acFibrechannelErrCounterTable 1 } AcFibrechannelErrCounterEntry ::= SEQUENCE { acFibrechannelErrCounterIndex INTEGER, acFibrechannelErrCounterTotalFrame Counter64, acFibrechannelErrCounterErroredFrame Counter64, acFibrechannelErrCounterDiscardFrame Counter64, acFibrechannelErrCounterLossofSync Counter64, acFibrechannelErrCounterLineError Counter64, acFibrechannelErrCounterFCSError Counter64, acFibrechannelErrCounterCheckError Counter64 } acFibrechannelErrCounterIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acFibrechannelErrCounterEntry 1 } acFibrechannelErrCounterTotalFrame OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of total frames at the physical interface." ::= { acFibrechannelErrCounterEntry 2 } acFibrechannelErrCounterErroredFrame OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of errored frames at the physical interface." ::= { acFibrechannelErrCounterEntry 3 } acFibrechannelErrCounterDiscardFrame OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of discarded frames at the physical interface." ::= { acFibrechannelErrCounterEntry 4 } acFibrechannelErrCounterLossofSync OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LossofSync at the physical interface." ::= { acFibrechannelErrCounterEntry 5 } acFibrechannelErrCounterLineError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LineError at the physical interface." ::= { acFibrechannelErrCounterEntry 6 } acFibrechannelErrCounterFCSError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type FCSError at the physical interface." ::= { acFibrechannelErrCounterEntry 7 } acFibrechannelErrCounterCheckError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type CheckError at the physical interface." ::= { acFibrechannelErrCounterEntry 8 } -- -- acFibrechannelEtsCounter part -- acFibrechannelEtsCounterNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical Fibrechannel interfaces." ::= { acFibrechannelEtsCounter 1 } acFibrechannelEtsCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF AcFibrechannelEtsCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Fibrechannel interface alarm informations. The number of entries is given by the value of acFibrechannelEtsCounterNumber." ::= { acFibrechannelEtsCounter 2 } acFibrechannelEtsCounterEntry OBJECT-TYPE SYNTAX AcFibrechannelEtsCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing alarm informations applicable to a particular physical Fibrechannel interface." INDEX { acFibrechannelEtsCounterIndex } ::= { acFibrechannelEtsCounterTable 1 } AcFibrechannelEtsCounterEntry ::= SEQUENCE { acFibrechannelEtsCounterIndex INTEGER, acFibrechannelEtsCounterTotalFrame Counter64, acFibrechannelEtsCounterErroredFrame Counter64, acFibrechannelEtsCounterDiscardFrame Counter64, acFibrechannelEtsCounterLossofSync Counter64, acFibrechannelEtsCounterLineError Counter64, acFibrechannelEtsCounterFCSError Counter64, acFibrechannelEtsCounterCheckError Counter64 } acFibrechannelEtsCounterIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { acFibrechannelEtsCounterEntry 1 } acFibrechannelEtsCounterTotalFrame OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "not defined." ::= { acFibrechannelEtsCounterEntry 2 } acFibrechannelEtsCounterErroredFrame OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of errored frames at the physical interface." ::= { acFibrechannelEtsCounterEntry 3 } acFibrechannelEtsCounterDiscardFrame OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of discarded frames at the physical interface." ::= { acFibrechannelEtsCounterEntry 4 } acFibrechannelEtsCounterLossofSync OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LossofSync at the physical interface." ::= { acFibrechannelEtsCounterEntry 5 } acFibrechannelEtsCounterLineError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type LineError at the physical interface." ::= { acFibrechannelEtsCounterEntry 6 } acFibrechannelEtsCounterFCSError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type FCSError at the physical interface." ::= { acFibrechannelEtsCounterEntry 7 } acFibrechannelEtsCounterCheckError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of error conditions of type CheckError at the physical interface." ::= { acFibrechannelEtsCounterEntry 8 } END