Webio-Digital-MIB-US DEFINITIONS ::= BEGIN ---------------------------------------------------------------- -- Revison: 1.55 ---------------------------------------------------------------- -- 12.12.2017 New: -- wtWebio577xxMQTTLastWillEnable -- wtWebio577xxMQTTLastWillTopic -- wtWebio577xxMQTTLastWillMsg -- wtWebio577xxMQTTLastWillQoS -- wtWebio577xxMQTTLastWillRetain -- wtWebio577xxMQTTLastWillConnectEnable -- wtWebio577xxMQTTLastWillConnectMsg ---------------------------------------------------------------- -- Revison: 1.54 ---------------------------------------------------------------- -- 29.08.2017 New: wtWebio577xxManagerPort -- wtWebio577xxMQTT_QoS -- wtWebio577xxMQTT_Retain ---------------------------------------------------------------- -- Revison: 1.53 ---------------------------------------------------------------- -- 23.01.2017 New: wtWebio577xxEA12x12 -- wtWebio577xxEA12x12Uart -- wtWebio577xxEA12x6Rel ---------------------------------------------------------------- -- Revison: 1.52 ---------------------------------------------------------------- -- 01.06.2016 New wtWebio577xxEA1x1 -- wtWebio577xxEA2x2 ---------------------------------------------------------------- -- Revison: 1.51 ---------------------------------------------------------------- -- 24.09.2012 Error correction -- ---------------------------------------------------------------- -- Revison: 1.50 ---------------------------------------------------------------- -- 21.01.2011 TrapReceiver -- Syntax correction ---------------------------------------------------------------- -- Revison: 1.49 ---------------------------------------------------------------- -- 27.07.2010 Update TrapReceiver -- ---------------------------------------------------------------- -- Revison: 1.48 ---------------------------------------------------------------- -- 22.06.2010 Webio -- Syntax correction ---------------------------------------------------------------- -- Revison: 1.47 ---------------------------------------------------------------- -- 23.04.2010 New: TrapReceiver Reports ---------------------------------------------------------------- -- Revison: 1.46 ---------------------------------------------------------------- -- 02.02.2010 New: 57638: ERP-Gateway PoE: Internal 24V -- 57655: IP-Watcher PoE: Internal 24V -- 57656: TrapReceiver 2x2 ---------------------------------------------------------------- -- Revison: 1.45 ---------------------------------------------------------------- -- 07.01.2010 New: 57654: IP List Alias Names -- ---------------------------------------------------------------- -- Revison: 1.44 ---------------------------------------------------------------- -- 24.11.2009 New: 57652: Add on Rate of Change -- UDP Remote Port ---------------------------------------------------------------- -- Revison: 1.43 ---------------------------------------------------------------- -- 06.11.2009 New: 57637: WebIO Digital 2x2 mit interner 24V -- Versorgung ---------------------------------------------------------------- -- Revison: 1.42 ---------------------------------------------------------------- -- 11.08.2009 Syntax correction -- ---------------------------------------------------------------- -- Revison: 1.41 ---------------------------------------------------------------- -- 15.06.2009 New: 57652: Rate of change -- ---------------------------------------------------------------- -- Revison: 1.40 ---------------------------------------------------------------- -- 17.04.2009 New: IP Watcher 57654 -- New: ERP Gateway 2x2 Digital 57635 -- New: ERP Gateway 6xRelais 57636 -- ---------------------------------------------------------------- -- Revison: 1.39 ---------------------------------------------------------------- -- 03.02.2009 New: WebIO Digital 6x6 Logger 57650 -- ---------------------------------------------------------------- -- Revison: 1.37 ---------------------------------------------------------------- -- 17.11.2008 Correction numbering OutputPortEntry -- ---------------------------------------------------------------- -- Revison: 1.36 ---------------------------------------------------------------- -- 03.09.2008 New: Web-Count 57652 -- ---------------------------------------------------------------- -- Revison: 1.35 ---------------------------------------------------------------- -- 20.08.2008 New: US Release Text -- Extensions ---------------------------------------------------------------- -- Revison: 1.34 ---------------------------------------------------------------- -- 08.08.2008 New: Web-Alarm 57651 -- Extensions ---------------------------------------------------------------- -- Revison: 1.33 ---------------------------------------------------------------- -- 24.06.2008 All: OutputState in group xxxInOut now read-write -- ---------------------------------------------------------------- -- Revison: 1.32 ---------------------------------------------------------------- -- 14.03.2008 WebAlarm 6x6 -- ---------------------------------------------------------------- -- Revison: 1.31 ---------------------------------------------------------------- -- 23.05.2007 Webio Digital -- new: Read(Write) Inputs/Outputs bitwise ---------------------------------------------------------------- -- Revison: 1.30 ---------------------------------------------------------------- -- 08.12.2006 Webio Digital -- new: 57634 ---------------------------------------------------------------- -- Revison: 1.29 ---------------------------------------------------------------- -- 09.11.2006 Webio Digital -- DHCP enable ---------------------------------------------------------------- -- Revison: 1.28 ---------------------------------------------------------------- -- 04.05.2006 #57632, Webio Digital -- new OEM device ---------------------------------------------------------------- -- Revison: 1.27 ---------------------------------------------------------------- -- 10.02.2006 #57630/1, Webio Digital -- Incremental Counter -- New: #57633 2x2 Webio Digital ---------------------------------------------------------------- -- Revison: 1.26 ---------------------------------------------------------------- -- 05.08.2005 #57630/1/2, Webio Digital -- CRON time functions -- FTP functions ---------------------------------------------------------------- -- Revison: 1.25 ---------------------------------------------------------------- -- 02.06.2005 #57630/1/2, Webio Digital -- Trap NMS annotations ---------------------------------------------------------------- -- Revison: 1.24 ---------------------------------------------------------------- -- 10.05.2005 #57630/1/2, Webio Digital -- Binary Mode: BIN-TCP-CLIENT-SERVER-HTTP-PORT -- Binary Mode: BIN-TCP-SERVER-CLIENT-HTTP-PORT ---------------------------------------------------------------- -- Revison: 1.23 ---------------------------------------------------------------- -- 19.04.2005 #57630/1/2, Webio Digital -- Mail Authentication -- PortInputMode: Change detection enable ---------------------------------------------------------------- -- Revison: 1.22 ---------------------------------------------------------------- -- 15.03.2005 #57630/1/2, Webio Digital -- variable HTTP port -- ---------------------------------------------------------------- -- Revison: 1.21 ---------------------------------------------------------------- -- 17.02.2005 #57630/1/2, Webio Digital -- 4 additional traps; new input/output alarm trigger -- ---------------------------------------------------------------- -- Revison: 1.20 ---------------------------------------------------------------- -- 13.12.2004 #57630/1/2, Webio Digital -- New: Size setoutput, alarminputtrigger, alarmoutputtrigger -- ---------------------------------------------------------------- -- Revison: 1.19 ---------------------------------------------------------------- -- 02.11.2004 #57630/1/2, Webio Digital -- New: Syslog -- ---------------------------------------------------------------- -- Revison: 1.18 ---------------------------------------------------------------- -- 12.07.2004 #57630/1/2, Webio Digital -- New: HTTP Input Trigger -- Diagnosis ---------------------------------------------------------------- -- Revison: 1.17 ---------------------------------------------------------------- -- 28.06.2004 #57630/1/2, Webio Digital -- Neu: Pulse Mode ---------------------------------------------------------------- -- Revison: 1.16 ---------------------------------------------------------------- -- 16.04.2004 New: #57632, Webio Digital EA24oem -- -- #57630/1, Webio Digital EA12x12 -- New: -- wtWebioEA12x12InputCounterClear ---------------------------------------------------------------- -- Revison: 1.15 ---------------------------------------------------------------- -- 27.02.2004 #57630/1, Webio Digital EA12x12 -- New: -- Length changed to 32 Bit: -- wtWebioEA12x12InputValue -- wtWebioEA12x12OutputValue -- wtWebioEA12x12LoadControlView -- wtWebioEA12x12LCShutDownView -- wtWebioEA12x12SetOutput -- wtWebioEA12x12AlarmInputTrigger -- wtWebioEA12x12AlarmOutputTrigger -- wtWebioEA12x12PortOutputSafetyState ---------------------------------------------------------------- -- Revison: 1.14 ---------------------------------------------------------------- -- 16.02.2004 #57630/1, Webio Digital EA12x12 -- New: -- Text: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger -- -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New: -- Alarm Hysteresis -- Alarm Clear Traps and Mails ---------------------------------------------------------------- -- Revison: 1.13 ---------------------------------------------------------------- -- 05.02.2004 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New: -- Text: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger ---------------------------------------------------------------- -- Revison: 1.12 ---------------------------------------------------------------- -- 05.11.2003 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New features: -- Mail : Option CSV attachment -- Port : Offset calibration -- Alarm : TCP Client mode ---------------------------------------------------------------- -- Revison: 1.11 ---------------------------------------------------------------- -- 28.10.2003 #57630/1, Webio Digital EA12x12 -- New features: -- Alarm : TCP Client mode -- Inputs: Pulse filter ---------------------------------------------------------------- -- Revison: 1.10 ---------------------------------------------------------------- -- 22.07.2003 #57630, Webio Digital EA12x12 -- New navigation tree, new binary modes -- ---------------------------------------------------------------- -- Revison: 1.09 ---------------------------------------------------------------- -- 24.03.2003 Trap Enterprise (Type 1, 2) corrected ---------------------------------------------------------------- -- Revison: 1.08 ---------------------------------------------------------------- -- 04.03.2003 reconciled the language versions DE/US ---------------------------------------------------------------- -- Revison: 1.07 ---------------------------------------------------------------- -- 25.02.2003 Correction: wtWebioEA12x12LoadControl ---------------------------------------------------------------- -- Revison: 1.06 ---------------------------------------------------------------- -- 24.02.2003 New: -- #57630, Webio EA12x12, LoadControl Group -- Correction: Trap variable names ---------------------------------------------------------------- -- Revison: 1.05 ---------------------------------------------------------------- -- 21.01.2003 New: -- #57630, Webio EA12x12 ---------------------------------------------------------------- -- Revison: 1.04 ---------------------------------------------------------------- -- 02.01.2003 New: -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer, 8 alarms ---------------------------------------------------------------- -- Revison: 1.03 ---------------------------------------------------------------- -- 21.11.2002 New: -- #57604, 2xWebThermometer, BOOTP, StartupSite -- #57603, 8xWebThermometer, BOOTP, StartupSite ---------------------------------------------------------------- -- Revison: 1.02 ---------------------------------------------------------------- -- 26.07.2002 New: -- #57604, 2xWebThermometer -- #57603, 8xWebThermometer -- IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, PhysAddress FROM RFC1213-MIB enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI; -- IpAddress ::= -- [APPLICATION 0] -- IMPLICIT OCTET STRING (SIZE (4)) -- Counter ::= -- [APPLICATION 1] -- IMPLICIT INTEGER (0..4294967295) -- Gauge ::= -- [APPLICATION 2] -- IMPLICIT INTEGER (0..4294967295) -- TimeTicks ::= -- [APPLICATION 3] -- IMPLICIT INTEGER (0..4294967295) -- DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING -- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } -- privat OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { privat 1 } -- Wiesemann & Theis Com-Server MIB wut OBJECT IDENTIFIER ::= { enterprises 5040 } wtComServer OBJECT IDENTIFIER ::= { wut 1 } wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 } -- wtWebio Tree wtWebioEA12x12 OBJECT IDENTIFIER ::= { wtWebio 4 } wtWebioEA2x2 OBJECT IDENTIFIER ::= { wtWebio 13 } wtWebioEA24oem OBJECT IDENTIFIER ::= { wtWebio 14 } wtWebioEA12x6Rel OBJECT IDENTIFIER ::= { wtWebio 19 } wtWebAlarm6x6 OBJECT IDENTIFIER ::= { wtWebio 20 } wtWebCount6 OBJECT IDENTIFIER ::= { wtWebio 22 } wtWebioEA6x6 OBJECT IDENTIFIER ::= { wtWebio 24 } wtWebioEA2x2ERP OBJECT IDENTIFIER ::= { wtWebio 25 } wtWebioEA12x6RelERP OBJECT IDENTIFIER ::= { wtWebio 26 } wtIpWatcher OBJECT IDENTIFIER ::= { wtWebio 27 } wtWebioEA2x2-24V OBJECT IDENTIFIER ::= { wtWebio 30 } wtWebioEA2x2ERP-24V OBJECT IDENTIFIER ::= { wtWebio 31 } wtIpWatcher-24V OBJECT IDENTIFIER ::= { wtWebio 32 } wtTrapReceiver2x2 OBJECT IDENTIFIER ::= { wtWebio 33 } wtWebio577xxEA1x1 OBJECT IDENTIFIER ::= { wtWebio 48 } wtWebio577xxEA12x12 OBJECT IDENTIFIER ::= { wtWebio 49 } wtWebio577xxEA12x12Uart OBJECT IDENTIFIER ::= { wtWebio 50 } wtWebio577xxEA12x6Rel OBJECT IDENTIFIER ::= { wtWebio 51 } wtWebio577xxEA2x2 OBJECT IDENTIFIER ::= { wtWebio 52 } -- wtWebio577xxEA1x1 Tree wtWebio577xxEA1x1InOut OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1 1 } wtWebio577xxEA1x1SessCntrl OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1 2 } wtWebio577xxEA1x1Config OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1 3 } wtWebio577xxEA1x1Diag OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1 4 } -- wtWebio577xxEA1x1Config Tree wtWebio577xxEA1x1Device OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Config 1 } wtWebio577xxEA1x1Ports OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Config 2 } wtWebio577xxEA1x1Manufact OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Config 3 } -- wtWebio577xxEA1x1Device Tree wtWebio577xxEA1x1Text OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Device 1 } wtWebio577xxEA1x1TimeDate OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Device 2 } wtWebio577xxEA1x1Basic OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Device 3 } wtWebio577xxEA1x1OutputMode OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Device 4 } wtWebio577xxEA1x1Alarm OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Device 5 } -- wtWebio577xxEA1x1Basic Tree wtWebio577xxEA1x1Network OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 1 } wtWebio577xxEA1x1HTTP OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 2 } wtWebio577xxEA1x1Mail OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 3 } wtWebio577xxEA1x1SNMP OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 4 } wtWebio577xxEA1x1UDP OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 5 } wtWebio577xxEA1x1Binary OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 6 } wtWebio577xxEA1x1Syslog OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 7 } wtWebio577xxEA1x1FTP OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 8 } wtWebio577xxEA1x1MQTT OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 12 } wtWebio577xxEA1x1REST OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 13 } -- wtWebio577xxEA1x1TimeDate Tree wtWebio577xxEA1x1TimeZone OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1TimeDate 1 } wtWebio577xxEA1x1TimeServer OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1TimeDate 2 } wtWebio577xxEA1x1DeviceClock OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1TimeDate 3 } -- wtWebio577xxEA2x2 Tree wtWebio577xxEA2x2InOut OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2 1 } wtWebio577xxEA2x2SessCntrl OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2 2 } wtWebio577xxEA2x2Config OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2 3 } wtWebio577xxEA2x2Diag OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2 4 } -- wtWebio577xxEA2x2Config Tree wtWebio577xxEA2x2Device OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Config 1 } wtWebio577xxEA2x2Ports OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Config 2 } wtWebio577xxEA2x2Manufact OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Config 3 } -- wtWebio577xxEA2x2Device Tree wtWebio577xxEA2x2Text OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Device 1 } wtWebio577xxEA2x2TimeDate OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Device 2 } wtWebio577xxEA2x2Basic OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Device 3 } wtWebio577xxEA2x2OutputMode OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Device 4 } wtWebio577xxEA2x2Alarm OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Device 5 } -- wtWebio577xxEA2x2Basic Tree wtWebio577xxEA2x2Network OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 1 } wtWebio577xxEA2x2HTTP OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 2 } wtWebio577xxEA2x2Mail OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 3 } wtWebio577xxEA2x2SNMP OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 4 } wtWebio577xxEA2x2UDP OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 5 } wtWebio577xxEA2x2Binary OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 6 } wtWebio577xxEA2x2Syslog OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 7 } wtWebio577xxEA2x2FTP OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 8 } wtWebio577xxEA2x2MQTT OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 12 } wtWebio577xxEA2x2REST OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 13 } -- wtWebio577xxEA2x2TimeDate Tree wtWebio577xxEA2x2TimeZone OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2TimeDate 1 } wtWebio577xxEA2x2TimeServer OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2TimeDate 2 } wtWebio577xxEA2x2DeviceClock OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2TimeDate 3 } -- wtWebioEA2x2 Tree wtWebioEA2x2InOut OBJECT IDENTIFIER ::= { wtWebioEA2x2 1 } wtWebioEA2x2SessCntrl OBJECT IDENTIFIER ::= { wtWebioEA2x2 2 } wtWebioEA2x2Config OBJECT IDENTIFIER ::= { wtWebioEA2x2 3 } wtWebioEA2x2Diag OBJECT IDENTIFIER ::= { wtWebioEA2x2 4 } -- wtWebioEA2x2Config Tree wtWebioEA2x2Device OBJECT IDENTIFIER ::= { wtWebioEA2x2Config 1 } wtWebioEA2x2Ports OBJECT IDENTIFIER ::= { wtWebioEA2x2Config 2 } wtWebioEA2x2Manufact OBJECT IDENTIFIER ::= { wtWebioEA2x2Config 3 } -- wtWebioEA2x2Device Tree wtWebioEA2x2Text OBJECT IDENTIFIER ::= { wtWebioEA2x2Device 1 } wtWebioEA2x2TimeDate OBJECT IDENTIFIER ::= { wtWebioEA2x2Device 2 } wtWebioEA2x2Basic OBJECT IDENTIFIER ::= { wtWebioEA2x2Device 3 } wtWebioEA2x2OutputMode OBJECT IDENTIFIER ::= { wtWebioEA2x2Device 4 } wtWebioEA2x2Alarm OBJECT IDENTIFIER ::= { wtWebioEA2x2Device 5 } -- wtWebioEA2x2Basic Tree wtWebioEA2x2Network OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 1 } wtWebioEA2x2HTTP OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 2 } wtWebioEA2x2Mail OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 3 } wtWebioEA2x2SNMP OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 4 } wtWebioEA2x2UDP OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 5 } wtWebioEA2x2Binary OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 6 } wtWebioEA2x2Syslog OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 7 } wtWebioEA2x2FTP OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 8 } -- wtWebioEA2x2TimeDate Tree wtWebioEA2x2TimeZone OBJECT IDENTIFIER ::= { wtWebioEA2x2TimeDate 1 } wtWebioEA2x2TimeServer OBJECT IDENTIFIER ::= { wtWebioEA2x2TimeDate 2 } wtWebioEA2x2DeviceClock OBJECT IDENTIFIER ::= { wtWebioEA2x2TimeDate 3 } -- wtWebio577xxEA12x12 Tree wtWebio577xxEA12x12InOut OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12 1 } wtWebio577xxEA12x12SessCntrl OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12 2 } wtWebio577xxEA12x12Config OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12 3 } wtWebio577xxEA12x12Diag OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12 4 } -- wtWebio577xxEA12x12Config Tree wtWebio577xxEA12x12Device OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Config 1 } wtWebio577xxEA12x12Ports OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Config 2 } wtWebio577xxEA12x12Manufact OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Config 3 } -- wtWebio577xxEA12x12Device Tree wtWebio577xxEA12x12Text OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Device 1 } wtWebio577xxEA12x12TimeDate OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Device 2 } wtWebio577xxEA12x12Basic OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Device 3 } wtWebio577xxEA12x12OutputMode OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Device 4 } wtWebio577xxEA12x12Alarm OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Device 5 } -- wtWebio577xxEA12x12Basic Tree wtWebio577xxEA12x12Network OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 1 } wtWebio577xxEA12x12HTTP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 2 } wtWebio577xxEA12x12Mail OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 3 } wtWebio577xxEA12x12SNMP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 4 } wtWebio577xxEA12x12UDP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 5 } wtWebio577xxEA12x12Binary OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 6 } wtWebio577xxEA12x12Syslog OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 7 } wtWebio577xxEA12x12FTP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 8 } wtWebio577xxEA12x12MQTT OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 12 } wtWebio577xxEA12x12REST OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 13 } -- wtWebio577xxEA12x12TimeDate Tree wtWebio577xxEA12x12TimeZone OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12TimeDate 1 } wtWebio577xxEA12x12TimeServer OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12TimeDate 2 } wtWebio577xxEA12x12DeviceClock OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12TimeDate 3 } -- wtWebioEA12x12 Tree wtWebioEA12x12InOut OBJECT IDENTIFIER ::= { wtWebioEA12x12 1 } wtWebioEA12x12SessCntrl OBJECT IDENTIFIER ::= { wtWebioEA12x12 2 } wtWebioEA12x12Config OBJECT IDENTIFIER ::= { wtWebioEA12x12 3 } wtWebioEA12x12Diag OBJECT IDENTIFIER ::= { wtWebioEA12x12 4 } -- wtWebioEA12x12Config Tree wtWebioEA12x12Device OBJECT IDENTIFIER ::= { wtWebioEA12x12Config 1 } wtWebioEA12x12Ports OBJECT IDENTIFIER ::= { wtWebioEA12x12Config 2 } wtWebioEA12x12Manufact OBJECT IDENTIFIER ::= { wtWebioEA12x12Config 3 } -- wtWebioEA12x12Device Tree wtWebioEA12x12Text OBJECT IDENTIFIER ::= { wtWebioEA12x12Device 1 } wtWebioEA12x12TimeDate OBJECT IDENTIFIER ::= { wtWebioEA12x12Device 2 } wtWebioEA12x12Basic OBJECT IDENTIFIER ::= { wtWebioEA12x12Device 3 } wtWebioEA12x12OutputMode OBJECT IDENTIFIER ::= { wtWebioEA12x12Device 4 } wtWebioEA12x12Alarm OBJECT IDENTIFIER ::= { wtWebioEA12x12Device 5 } -- wtWebioEA12x12Basic Tree wtWebioEA12x12Network OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 1 } wtWebioEA12x12HTTP OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 2 } wtWebioEA12x12Mail OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 3 } wtWebioEA12x12SNMP OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 4 } wtWebioEA12x12UDP OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 5 } wtWebioEA12x12Binary OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 6 } wtWebioEA12x12Syslog OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 7 } wtWebioEA12x12FTP OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 8 } -- wtWebioEA12x12TimeDate Tree wtWebioEA12x12TimeZone OBJECT IDENTIFIER ::= { wtWebioEA12x12TimeDate 1 } wtWebioEA12x12TimeServer OBJECT IDENTIFIER ::= { wtWebioEA12x12TimeDate 2 } wtWebioEA12x12DeviceClock OBJECT IDENTIFIER ::= { wtWebioEA12x12TimeDate 3 } -- wtWebioEA24oem Tree wtWebioEA24oemInOut OBJECT IDENTIFIER ::= { wtWebioEA24oem 1 } wtWebioEA24oemSessCntrl OBJECT IDENTIFIER ::= { wtWebioEA24oem 2 } wtWebioEA24oemConfig OBJECT IDENTIFIER ::= { wtWebioEA24oem 3 } wtWebioEA24oemDiag OBJECT IDENTIFIER ::= { wtWebioEA24oem 4 } -- wtWebioEA24oemConfig Tree wtWebioEA24oemDevice OBJECT IDENTIFIER ::= { wtWebioEA24oemConfig 1 } wtWebioEA24oemPorts OBJECT IDENTIFIER ::= { wtWebioEA24oemConfig 2 } wtWebioEA24oemManufact OBJECT IDENTIFIER ::= { wtWebioEA24oemConfig 3 } -- wtWebioEA24oemDevice Tree wtWebioEA24oemText OBJECT IDENTIFIER ::= { wtWebioEA24oemDevice 1 } wtWebioEA24oemTimeDate OBJECT IDENTIFIER ::= { wtWebioEA24oemDevice 2 } wtWebioEA24oemBasic OBJECT IDENTIFIER ::= { wtWebioEA24oemDevice 3 } wtWebioEA24oemOutputMode OBJECT IDENTIFIER ::= { wtWebioEA24oemDevice 4 } wtWebioEA24oemAlarm OBJECT IDENTIFIER ::= { wtWebioEA24oemDevice 5 } -- wtWebioEA24oemBasic Tree wtWebioEA24oemNetwork OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 1 } wtWebioEA24oemHTTP OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 2 } wtWebioEA24oemMail OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 3 } wtWebioEA24oemSNMP OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 4 } wtWebioEA24oemUDP OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 5 } wtWebioEA24oemBinary OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 6 } wtWebioEA24oemSyslog OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 7 } wtWebioEA24oemFTP OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 8 } -- wtWebioEA24oemTimeDate Tree wtWebioEA24oemTimeZone OBJECT IDENTIFIER ::= { wtWebioEA24oemTimeDate 1 } wtWebioEA24oemTimeServer OBJECT IDENTIFIER ::= { wtWebioEA24oemTimeDate 2 } wtWebioEA24oemDeviceClock OBJECT IDENTIFIER ::= { wtWebioEA24oemTimeDate 3 } -- wtWebio577xxEA12x6Rel Tree wtWebio577xxEA12x6RelInOut OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6Rel 1 } wtWebio577xxEA12x6RelSessCntrl OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6Rel 2 } wtWebio577xxEA12x6RelConfig OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6Rel 3 } wtWebio577xxEA12x6RelDiag OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6Rel 4 } -- wtWebio577xxEA12x6RelConfig Tree wtWebio577xxEA12x6RelDevice OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelConfig 1 } wtWebio577xxEA12x6RelPorts OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelConfig 2 } wtWebio577xxEA12x6RelManufact OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelConfig 3 } -- wtWebio577xxEA12x6RelDevice Tree wtWebio577xxEA12x6RelText OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelDevice 1 } wtWebio577xxEA12x6RelTimeDate OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelDevice 2 } wtWebio577xxEA12x6RelBasic OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelDevice 3 } wtWebio577xxEA12x6RelOutputMode OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelDevice 4 } wtWebio577xxEA12x6RelAlarm OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelDevice 5 } -- wtWebio577xxEA12x6RelBasic Tree wtWebio577xxEA12x6RelNetwork OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 1 } wtWebio577xxEA12x6RelHTTP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 2 } wtWebio577xxEA12x6RelMail OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 3 } wtWebio577xxEA12x6RelSNMP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 4 } wtWebio577xxEA12x6RelUDP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 5 } wtWebio577xxEA12x6RelBinary OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 6 } wtWebio577xxEA12x6RelSyslog OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 7 } wtWebio577xxEA12x6RelFTP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 8 } wtWebio577xxEA12x6RelMQTT OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 12 } wtWebio577xxEA12x6RelREST OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 13 } -- wtWebio577xxEA12x6RelTimeDate Tree wtWebio577xxEA12x6RelTimeZone OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelTimeDate 1 } wtWebio577xxEA12x6RelTimeServer OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelTimeDate 2 } wtWebio577xxEA12x6RelDeviceClock OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelTimeDate 3 } -- wtWebioEA12x6Rel Tree wtWebioEA12x6RelInOut OBJECT IDENTIFIER ::= { wtWebioEA12x6Rel 1 } wtWebioEA12x6RelSessCntrl OBJECT IDENTIFIER ::= { wtWebioEA12x6Rel 2 } wtWebioEA12x6RelConfig OBJECT IDENTIFIER ::= { wtWebioEA12x6Rel 3 } wtWebioEA12x6RelDiag OBJECT IDENTIFIER ::= { wtWebioEA12x6Rel 4 } -- wtWebioEA12x6RelConfig Tree wtWebioEA12x6RelDevice OBJECT IDENTIFIER ::= { wtWebioEA12x6RelConfig 1 } wtWebioEA12x6RelPorts OBJECT IDENTIFIER ::= { wtWebioEA12x6RelConfig 2 } wtWebioEA12x6RelManufact OBJECT IDENTIFIER ::= { wtWebioEA12x6RelConfig 3 } -- wtWebioEA12x6RelDevice Tree wtWebioEA12x6RelText OBJECT IDENTIFIER ::= { wtWebioEA12x6RelDevice 1 } wtWebioEA12x6RelTimeDate OBJECT IDENTIFIER ::= { wtWebioEA12x6RelDevice 2 } wtWebioEA12x6RelBasic OBJECT IDENTIFIER ::= { wtWebioEA12x6RelDevice 3 } wtWebioEA12x6RelOutputMode OBJECT IDENTIFIER ::= { wtWebioEA12x6RelDevice 4 } wtWebioEA12x6RelAlarm OBJECT IDENTIFIER ::= { wtWebioEA12x6RelDevice 5 } -- wtWebioEA12x6RelBasic Tree wtWebioEA12x6RelNetwork OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 1 } wtWebioEA12x6RelHTTP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 2 } wtWebioEA12x6RelMail OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 3 } wtWebioEA12x6RelSNMP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 4 } wtWebioEA12x6RelUDP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 5 } wtWebioEA12x6RelBinary OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 6 } wtWebioEA12x6RelSyslog OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 7 } wtWebioEA12x6RelFTP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 8 } -- wtWebioEA12x6RelTimeDate Tree wtWebioEA12x6RelTimeZone OBJECT IDENTIFIER ::= { wtWebioEA12x6RelTimeDate 1 } wtWebioEA12x6RelTimeServer OBJECT IDENTIFIER ::= { wtWebioEA12x6RelTimeDate 2 } wtWebioEA12x6RelDeviceClock OBJECT IDENTIFIER ::= { wtWebioEA12x6RelTimeDate 3 } -- wtWebAlarm6x6 Tree wtWebAlarm6x6InOut OBJECT IDENTIFIER ::= { wtWebAlarm6x6 1 } wtWebAlarm6x6SessCntrl OBJECT IDENTIFIER ::= { wtWebAlarm6x6 2 } wtWebAlarm6x6Config OBJECT IDENTIFIER ::= { wtWebAlarm6x6 3 } wtWebAlarm6x6Diag OBJECT IDENTIFIER ::= { wtWebAlarm6x6 4 } -- wtWebAlarm6x6Config Tree wtWebAlarm6x6Device OBJECT IDENTIFIER ::= { wtWebAlarm6x6Config 1 } wtWebAlarm6x6Ports OBJECT IDENTIFIER ::= { wtWebAlarm6x6Config 2 } wtWebAlarm6x6Manufact OBJECT IDENTIFIER ::= { wtWebAlarm6x6Config 3 } -- wtWebAlarm6x6Device Tree wtWebAlarm6x6Text OBJECT IDENTIFIER ::= { wtWebAlarm6x6Device 1 } wtWebAlarm6x6TimeDate OBJECT IDENTIFIER ::= { wtWebAlarm6x6Device 2 } wtWebAlarm6x6Basic OBJECT IDENTIFIER ::= { wtWebAlarm6x6Device 3 } wtWebAlarm6x6Alarm OBJECT IDENTIFIER ::= { wtWebAlarm6x6Device 5 } -- wtWebAlarm6x6Basic Tree wtWebAlarm6x6Network OBJECT IDENTIFIER ::= { wtWebAlarm6x6Basic 1 } wtWebAlarm6x6HTTP OBJECT IDENTIFIER ::= { wtWebAlarm6x6Basic 2 } wtWebAlarm6x6Mail OBJECT IDENTIFIER ::= { wtWebAlarm6x6Basic 3 } wtWebAlarm6x6SNMP OBJECT IDENTIFIER ::= { wtWebAlarm6x6Basic 4 } wtWebAlarm6x6UDP OBJECT IDENTIFIER ::= { wtWebAlarm6x6Basic 5 } wtWebAlarm6x6Syslog OBJECT IDENTIFIER ::= { wtWebAlarm6x6Basic 7 } wtWebAlarm6x6FTP OBJECT IDENTIFIER ::= { wtWebAlarm6x6Basic 8 } -- wtWebAlarm6x6TimeDate Tree wtWebAlarm6x6TimeZone OBJECT IDENTIFIER ::= { wtWebAlarm6x6TimeDate 1 } wtWebAlarm6x6TimeServer OBJECT IDENTIFIER ::= { wtWebAlarm6x6TimeDate 2 } wtWebAlarm6x6DeviceClock OBJECT IDENTIFIER ::= { wtWebAlarm6x6TimeDate 3 } -- wtWebCount6 Tree wtWebCount6InOut OBJECT IDENTIFIER ::= { wtWebCount6 1 } wtWebCount6SessCntrl OBJECT IDENTIFIER ::= { wtWebCount6 2 } wtWebCount6Config OBJECT IDENTIFIER ::= { wtWebCount6 3 } wtWebCount6Diag OBJECT IDENTIFIER ::= { wtWebCount6 4 } -- wtWebCount6Config Tree wtWebCount6Device OBJECT IDENTIFIER ::= { wtWebCount6Config 1 } wtWebCount6Ports OBJECT IDENTIFIER ::= { wtWebCount6Config 2 } wtWebCount6Manufact OBJECT IDENTIFIER ::= { wtWebCount6Config 3 } -- wtWebCount6Device Tree wtWebCount6Text OBJECT IDENTIFIER ::= { wtWebCount6Device 1 } wtWebCount6TimeDate OBJECT IDENTIFIER ::= { wtWebCount6Device 2 } wtWebCount6Basic OBJECT IDENTIFIER ::= { wtWebCount6Device 3 } wtWebCount6Report OBJECT IDENTIFIER ::= { wtWebCount6Device 5 } -- wtWebCount6Basic Tree wtWebCount6Network OBJECT IDENTIFIER ::= { wtWebCount6Basic 1 } wtWebCount6HTTP OBJECT IDENTIFIER ::= { wtWebCount6Basic 2 } wtWebCount6Mail OBJECT IDENTIFIER ::= { wtWebCount6Basic 3 } wtWebCount6SNMP OBJECT IDENTIFIER ::= { wtWebCount6Basic 4 } wtWebCount6UDP OBJECT IDENTIFIER ::= { wtWebCount6Basic 5 } wtWebCount6Syslog OBJECT IDENTIFIER ::= { wtWebCount6Basic 7 } wtWebCount6FTP OBJECT IDENTIFIER ::= { wtWebCount6Basic 8 } -- wtWebCount6TimeDate Tree wtWebCount6TimeZone OBJECT IDENTIFIER ::= { wtWebCount6TimeDate 1 } wtWebCount6TimeServer OBJECT IDENTIFIER ::= { wtWebCount6TimeDate 2 } wtWebCount6DeviceClock OBJECT IDENTIFIER ::= { wtWebCount6TimeDate 3 } -- wtWebioEA6x6 Tree wtWebioEA6x6InOut OBJECT IDENTIFIER ::= { wtWebioEA6x6 1 } wtWebioEA6x6SessCntrl OBJECT IDENTIFIER ::= { wtWebioEA6x6 2 } wtWebioEA6x6Config OBJECT IDENTIFIER ::= { wtWebioEA6x6 3 } wtWebioEA6x6Diag OBJECT IDENTIFIER ::= { wtWebioEA6x6 4 } -- wtWebioEA6x6Config Tree wtWebioEA6x6Device OBJECT IDENTIFIER ::= { wtWebioEA6x6Config 1 } wtWebioEA6x6Ports OBJECT IDENTIFIER ::= { wtWebioEA6x6Config 2 } wtWebioEA6x6Manufact OBJECT IDENTIFIER ::= { wtWebioEA6x6Config 3 } -- wtWebioEA6x6Device Tree wtWebioEA6x6Text OBJECT IDENTIFIER ::= { wtWebioEA6x6Device 1 } wtWebioEA6x6TimeDate OBJECT IDENTIFIER ::= { wtWebioEA6x6Device 2 } wtWebioEA6x6Basic OBJECT IDENTIFIER ::= { wtWebioEA6x6Device 3 } wtWebioEA6x6OutputMode OBJECT IDENTIFIER ::= { wtWebioEA6x6Device 4 } wtWebioEA6x6Alarm OBJECT IDENTIFIER ::= { wtWebioEA6x6Device 5 } -- wtWebioEA6x6Basic Tree wtWebioEA6x6Network OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 1 } wtWebioEA6x6HTTP OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 2 } wtWebioEA6x6Mail OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 3 } wtWebioEA6x6SNMP OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 4 } wtWebioEA6x6UDP OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 5 } wtWebioEA6x6Binary OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 6 } wtWebioEA6x6Syslog OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 7 } wtWebioEA6x6FTP OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 8 } -- wtWebioEA6x6TimeDate Tree wtWebioEA6x6TimeZone OBJECT IDENTIFIER ::= { wtWebioEA6x6TimeDate 1 } wtWebioEA6x6TimeServer OBJECT IDENTIFIER ::= { wtWebioEA6x6TimeDate 2 } wtWebioEA6x6DeviceClock OBJECT IDENTIFIER ::= { wtWebioEA6x6TimeDate 3 } -- wtWebioEA2x2ERP Tree wtWebioEA2x2ERPInOut OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP 1 } wtWebioEA2x2ERPSessCntrl OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP 2 } wtWebioEA2x2ERPConfig OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP 3 } wtWebioEA2x2ERPDiag OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP 4 } -- wtWebioEA2x2ERPConfig Tree wtWebioEA2x2ERPDevice OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPConfig 1 } wtWebioEA2x2ERPPorts OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPConfig 2 } wtWebioEA2x2ERPManufact OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPConfig 3 } -- wtWebioEA2x2ERPDevice Tree wtWebioEA2x2ERPText OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPDevice 1 } wtWebioEA2x2ERPTimeDate OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPDevice 2 } wtWebioEA2x2ERPBasic OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPDevice 3 } wtWebioEA2x2ERPOutputMode OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPDevice 4 } wtWebioEA2x2ERPAlarm OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPDevice 5 } -- wtWebioEA2x2ERPBasic Tree wtWebioEA2x2ERPNetwork OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 1 } wtWebioEA2x2ERPHTTP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 2 } wtWebioEA2x2ERPMail OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 3 } wtWebioEA2x2ERPSNMP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 4 } wtWebioEA2x2ERPUDP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 5 } wtWebioEA2x2ERPBinary OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 6 } wtWebioEA2x2ERPSyslog OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 7 } wtWebioEA2x2ERPFTP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 8 } wtWebioEA2x2ERPWayBack OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 10 } -- wtWebioEA2x2ERPTimeDate Tree wtWebioEA2x2ERPTimeZone OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPTimeDate 1 } wtWebioEA2x2ERPTimeServer OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPTimeDate 2 } wtWebioEA2x2ERPDeviceClock OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPTimeDate 3 } -- wtWebioEA12x6RelERP Tree wtWebioEA12x6RelERPInOut OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERP 1 } wtWebioEA12x6RelERPSessCntrl OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERP 2 } wtWebioEA12x6RelERPConfig OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERP 3 } wtWebioEA12x6RelERPDiag OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERP 4 } -- wtWebioEA12x6RelERPConfig Tree wtWebioEA12x6RelERPDevice OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPConfig 1 } wtWebioEA12x6RelERPPorts OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPConfig 2 } wtWebioEA12x6RelERPManufact OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPConfig 3 } -- wtWebioEA12x6RelERPDevice Tree wtWebioEA12x6RelERPText OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPDevice 1 } wtWebioEA12x6RelERPTimeDate OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPDevice 2 } wtWebioEA12x6RelERPBasic OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPDevice 3 } wtWebioEA12x6RelERPOutputMode OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPDevice 4 } wtWebioEA12x6RelERPAlarm OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPDevice 5 } -- wtWebioEA12x6RelERPBasic Tree wtWebioEA12x6RelERPNetwork OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 1 } wtWebioEA12x6RelERPHTTP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 2 } wtWebioEA12x6RelERPMail OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 3 } wtWebioEA12x6RelERPSNMP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 4 } wtWebioEA12x6RelERPUDP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 5 } wtWebioEA12x6RelERPBinary OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 6 } wtWebioEA12x6RelERPSyslog OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 7 } wtWebioEA12x6RelERPFTP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 8 } wtWebioEA12x6RelERPWayBack OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 10 } -- wtWebioEA12x6RelERPTimeDate Tree wtWebioEA12x6RelERPTimeZone OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPTimeDate 1 } wtWebioEA12x6RelERPTimeServer OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPTimeDate 2 } wtWebioEA12x6RelERPDeviceClock OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPTimeDate 3 } -- wtIpWatcher Tree wtIpWatcherInOut OBJECT IDENTIFIER ::= { wtIpWatcher 1 } wtIpWatcherSessCntrl OBJECT IDENTIFIER ::= { wtIpWatcher 2 } wtIpWatcherConfig OBJECT IDENTIFIER ::= { wtIpWatcher 3 } wtIpWatcherDiag OBJECT IDENTIFIER ::= { wtIpWatcher 4 } -- wtIpWatcherConfig Tree wtIpWatcherDevice OBJECT IDENTIFIER ::= { wtIpWatcherConfig 1 } wtIpWatcherPorts OBJECT IDENTIFIER ::= { wtIpWatcherConfig 2 } wtIpWatcherManufact OBJECT IDENTIFIER ::= { wtIpWatcherConfig 3 } -- wtIpWatcherDevice Tree wtIpWatcherText OBJECT IDENTIFIER ::= { wtIpWatcherDevice 1 } wtIpWatcherTimeDate OBJECT IDENTIFIER ::= { wtIpWatcherDevice 2 } wtIpWatcherBasic OBJECT IDENTIFIER ::= { wtIpWatcherDevice 3 } wtIpWatcherAlarm OBJECT IDENTIFIER ::= { wtIpWatcherDevice 5 } -- wtIpWatcherBasic Tree wtIpWatcherNetwork OBJECT IDENTIFIER ::= { wtIpWatcherBasic 1 } wtIpWatcherHTTP OBJECT IDENTIFIER ::= { wtIpWatcherBasic 2 } wtIpWatcherMail OBJECT IDENTIFIER ::= { wtIpWatcherBasic 3 } wtIpWatcherSNMP OBJECT IDENTIFIER ::= { wtIpWatcherBasic 4 } wtIpWatcherUDP OBJECT IDENTIFIER ::= { wtIpWatcherBasic 5 } wtIpWatcherSyslog OBJECT IDENTIFIER ::= { wtIpWatcherBasic 7 } wtIpWatcherFTP OBJECT IDENTIFIER ::= { wtIpWatcherBasic 8 } wtIpWatcherIpList OBJECT IDENTIFIER ::= { wtIpWatcherBasic 11 } -- wtIpWatcherTimeDate Tree wtIpWatcherTimeZone OBJECT IDENTIFIER ::= { wtIpWatcherTimeDate 1 } wtIpWatcherTimeServer OBJECT IDENTIFIER ::= { wtIpWatcherTimeDate 2 } wtIpWatcherDeviceClock OBJECT IDENTIFIER ::= { wtIpWatcherTimeDate 3 } -- wtWebioEA2x2-24V Tree wtWebioEA2x2-24VInOut OBJECT IDENTIFIER ::= { wtWebioEA2x2-24V 1 } wtWebioEA2x2-24VSessCntrl OBJECT IDENTIFIER ::= { wtWebioEA2x2-24V 2 } wtWebioEA2x2-24VConfig OBJECT IDENTIFIER ::= { wtWebioEA2x2-24V 3 } wtWebioEA2x2-24VDiag OBJECT IDENTIFIER ::= { wtWebioEA2x2-24V 4 } -- wtWebioEA2x2-24VConfig Tree wtWebioEA2x2-24VDevice OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VConfig 1 } wtWebioEA2x2-24VPorts OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VConfig 2 } wtWebioEA2x2-24VManufact OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VConfig 3 } -- wtWebioEA2x2-24VDevice Tree wtWebioEA2x2-24VText OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VDevice 1 } wtWebioEA2x2-24VTimeDate OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VDevice 2 } wtWebioEA2x2-24VBasic OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VDevice 3 } wtWebioEA2x2-24VOutputMode OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VDevice 4 } wtWebioEA2x2-24VAlarm OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VDevice 5 } -- wtWebioEA2x2-24VBasic Tree wtWebioEA2x2-24VNetwork OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 1 } wtWebioEA2x2-24VHTTP OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 2 } wtWebioEA2x2-24VMail OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 3 } wtWebioEA2x2-24VSNMP OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 4 } wtWebioEA2x2-24VUDP OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 5 } wtWebioEA2x2-24VBinary OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 6 } wtWebioEA2x2-24VSyslog OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 7 } wtWebioEA2x2-24VFTP OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 8 } -- wtWebioEA2x2-24VTimeDate Tree wtWebioEA2x2-24VTimeZone OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VTimeDate 1 } wtWebioEA2x2-24VTimeServer OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VTimeDate 2 } wtWebioEA2x2-24VDeviceClock OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VTimeDate 3 } -- wtWebioEA2x2ERP-24V Tree wtWebioEA2x2ERP-24VInOut OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24V 1 } wtWebioEA2x2ERP-24VSessCntrl OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24V 2 } wtWebioEA2x2ERP-24VConfig OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24V 3 } wtWebioEA2x2ERP-24VDiag OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24V 4 } -- wtWebioEA2x2ERP-24VConfig Tree wtWebioEA2x2ERP-24VDevice OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VConfig 1 } wtWebioEA2x2ERP-24VPorts OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VConfig 2 } wtWebioEA2x2ERP-24VManufact OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VConfig 3 } -- wtWebioEA2x2ERP-24VDevice Tree wtWebioEA2x2ERP-24VText OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VDevice 1 } wtWebioEA2x2ERP-24VTimeDate OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VDevice 2 } wtWebioEA2x2ERP-24VBasic OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VDevice 3 } wtWebioEA2x2ERP-24VOutputMode OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VDevice 4 } wtWebioEA2x2ERP-24VAlarm OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VDevice 5 } -- wtWebioEA2x2ERP-24VBasic Tree wtWebioEA2x2ERP-24VNetwork OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 1 } wtWebioEA2x2ERP-24VHTTP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 2 } wtWebioEA2x2ERP-24VMail OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 3 } wtWebioEA2x2ERP-24VSNMP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 4 } wtWebioEA2x2ERP-24VUDP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 5 } wtWebioEA2x2ERP-24VBinary OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 6 } wtWebioEA2x2ERP-24VSyslog OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 7 } wtWebioEA2x2ERP-24VFTP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 8 } wtWebioEA2x2ERP-24VWayBack OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 10 } -- wtWebioEA2x2ERP-24VTimeDate Tree wtWebioEA2x2ERP-24VTimeZone OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VTimeDate 1 } wtWebioEA2x2ERP-24VTimeServer OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VTimeDate 2 } wtWebioEA2x2ERP-24VDeviceClock OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VTimeDate 3 } -- wtIpWatcher-24V Tree wtIpWatcher-24VInOut OBJECT IDENTIFIER ::= { wtIpWatcher-24V 1 } wtIpWatcher-24VSessCntrl OBJECT IDENTIFIER ::= { wtIpWatcher-24V 2 } wtIpWatcher-24VConfig OBJECT IDENTIFIER ::= { wtIpWatcher-24V 3 } wtIpWatcher-24VDiag OBJECT IDENTIFIER ::= { wtIpWatcher-24V 4 } -- wtIpWatcher-24VConfig Tree wtIpWatcher-24VDevice OBJECT IDENTIFIER ::= { wtIpWatcher-24VConfig 1 } wtIpWatcher-24VPorts OBJECT IDENTIFIER ::= { wtIpWatcher-24VConfig 2 } wtIpWatcher-24VManufact OBJECT IDENTIFIER ::= { wtIpWatcher-24VConfig 3 } -- wtIpWatcher-24VDevice Tree wtIpWatcher-24VText OBJECT IDENTIFIER ::= { wtIpWatcher-24VDevice 1 } wtIpWatcher-24VTimeDate OBJECT IDENTIFIER ::= { wtIpWatcher-24VDevice 2 } wtIpWatcher-24VBasic OBJECT IDENTIFIER ::= { wtIpWatcher-24VDevice 3 } wtIpWatcher-24VOutputMode OBJECT IDENTIFIER ::= { wtIpWatcher-24VDevice 4 } wtIpWatcher-24VAlarm OBJECT IDENTIFIER ::= { wtIpWatcher-24VDevice 5 } -- wtIpWatcher-24VBasic Tree wtIpWatcher-24VNetwork OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 1 } wtIpWatcher-24VHTTP OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 2 } wtIpWatcher-24VMail OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 3 } wtIpWatcher-24VSNMP OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 4 } wtIpWatcher-24VUDP OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 5 } wtIpWatcher-24VSyslog OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 7 } wtIpWatcher-24VFTP OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 8 } wtIpWatcher-24VIpList OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 11 } -- wtIpWatcher-24VTimeDate Tree wtIpWatcher-24VTimeZone OBJECT IDENTIFIER ::= { wtIpWatcher-24VTimeDate 1 } wtIpWatcher-24VTimeServer OBJECT IDENTIFIER ::= { wtIpWatcher-24VTimeDate 2 } wtIpWatcher-24VDeviceClock OBJECT IDENTIFIER ::= { wtIpWatcher-24VTimeDate 3 } -- wtTrapReceiver2x2 Tree wtTrapReceiver2x2InOut OBJECT IDENTIFIER ::= { wtTrapReceiver2x2 1 } wtTrapReceiver2x2SessCntrl OBJECT IDENTIFIER ::= { wtTrapReceiver2x2 2 } wtTrapReceiver2x2Config OBJECT IDENTIFIER ::= { wtTrapReceiver2x2 3 } wtTrapReceiver2x2Diag OBJECT IDENTIFIER ::= { wtTrapReceiver2x2 4 } -- wtTrapReceiver2x2Config Tree wtTrapReceiver2x2Device OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Config 1 } wtTrapReceiver2x2Ports OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Config 2 } wtTrapReceiver2x2Manufact OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Config 3 } -- wtTrapReceiver2x2Device Tree wtTrapReceiver2x2Text OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Device 1 } wtTrapReceiver2x2TimeDate OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Device 2 } wtTrapReceiver2x2Basic OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Device 3 } wtTrapReceiver2x2OutputMode OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Device 4 } wtTrapReceiver2x2Action OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Device 5 } wtTrapReceiver2x2PrepareInEvents OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Device 6 } wtTrapReceiver2x2PrepareOutEvents OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Device 7 } -- wtTrapReceiver2x2Basic Tree wtTrapReceiver2x2Network OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Basic 1 } wtTrapReceiver2x2HTTP OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Basic 2 } wtTrapReceiver2x2Mail OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Basic 3 } wtTrapReceiver2x2SNMP OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Basic 4 } wtTrapReceiver2x2UDP OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Basic 5 } wtTrapReceiver2x2Syslog OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Basic 7 } wtTrapReceiver2x2FTP OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Basic 8 } -- wtTrapReceiver2x2TimeDate Tree wtTrapReceiver2x2TimeZone OBJECT IDENTIFIER ::= { wtTrapReceiver2x2TimeDate 1 } wtTrapReceiver2x2TimeServer OBJECT IDENTIFIER ::= { wtTrapReceiver2x2TimeDate 2 } wtTrapReceiver2x2DeviceClock OBJECT IDENTIFIER ::= { wtTrapReceiver2x2TimeDate 3 } -- wtTrapReceiver2x2PrepareInEvents wtTrapReceiver2x2WatchList OBJECT IDENTIFIER ::= { wtTrapReceiver2x2PrepareInEvents 1 } wtTrapReceiver2x2InEvSystemTimer OBJECT IDENTIFIER ::= { wtTrapReceiver2x2PrepareInEvents 2 } wtTrapReceiver2x2InEvButtons OBJECT IDENTIFIER ::= { wtTrapReceiver2x2PrepareInEvents 3 } wtTrapReceiver2x2InEvInputs OBJECT IDENTIFIER ::= { wtTrapReceiver2x2PrepareInEvents 4 } -- wtTrapReceiver2x2PrepareOutEvents wtTrapReceiver2x2OutEvOutputs OBJECT IDENTIFIER ::= { wtTrapReceiver2x2PrepareOutEvents 1 } -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebio577xxEA1x1InOut Group ------------------------ wtWebio577xxEA1x1Inputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtWebio577xxEA1x1InOut 1 } wtWebio577xxEA1x1Outputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent outputs." ::= { wtWebio577xxEA1x1InOut 2 } -- Input Interface Table wtWebio577xxEA1x1InputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA1x1InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebio577xxEA1x1InOut 3 } wtWebio577xxEA1x1InputEntry OBJECT-TYPE SYNTAX WtWebio577xxEA1x1InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtWebio577xxEA1x1InputNo } ::= { wtWebio577xxEA1x1InputTable 1 } WtWebio577xxEA1x1InputEntry ::= SEQUENCE { wtWebio577xxEA1x1InputNo INTEGER, wtWebio577xxEA1x1InputCounter INTEGER, wtWebio577xxEA1x1InputCounterClear INTEGER, wtWebio577xxEA1x1InputState INTEGER } wtWebio577xxEA1x1InputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebio577xxEA1x1InputEntry 1 } wtWebio577xxEA1x1InputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebio577xxEA1x1InputEntry 2 } wtWebio577xxEA1x1InputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtWebio577xxEA1x1InputEntry 3 } wtWebio577xxEA1x1InputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of a single input bit, 0-OFF, 1-ON." ::= { wtWebio577xxEA1x1InputEntry 4 } wtWebio577xxEA1x1InputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1" ::= { wtWebio577xxEA1x1InOut 4 } -- Output Interface Table wtWebio577xxEA1x1OutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA1x1OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtWebio577xxEA1x1InOut 5 } wtWebio577xxEA1x1OutputEntry OBJECT-TYPE SYNTAX WtWebio577xxEA1x1OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtWebio577xxEA1x1OutputNo } ::= { wtWebio577xxEA1x1OutputTable 1 } WtWebio577xxEA1x1OutputEntry ::= SEQUENCE { wtWebio577xxEA1x1OutputNo INTEGER, wtWebio577xxEA1x1OutputState INTEGER } wtWebio577xxEA1x1OutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtWebio577xxEA1x1OutputEntry 1 } wtWebio577xxEA1x1OutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of a single output bit, 0-OFF, 1-ON." ::= { wtWebio577xxEA1x1OutputEntry 2 } wtWebio577xxEA1x1OutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt" ::= { wtWebio577xxEA1x1InOut 6 } wtWebio577xxEA1x1SetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1" ::= { wtWebio577xxEA1x1InOut 7 } -- wtWebio577xxEA1x1SessCntrl Group -------------------------------- wtWebio577xxEA1x1SessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebio577xxEA1x1SessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebio577xxEA1x1SessCntrl 1 } wtWebio577xxEA1x1SessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebio577xxEA1x1SessCntrl 2 } wtWebio577xxEA1x1SessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebio577xxEA1x1SessCntrl 3 } wtWebio577xxEA1x1SessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebio577xxEA1x1SessCntrl 4 } wtWebio577xxEA1x1SessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebio577xxEA1x1SessCntrl 5 } -- wtWebio577xxEA1x1Text Group ------------------------ wtWebio577xxEA1x1DeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebio577xxEA1x1Text 1 } wtWebio577xxEA1x1DeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebio577xxEA1x1Text 2 } wtWebio577xxEA1x1DeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebio577xxEA1x1Text 3 } wtWebio577xxEA1x1DeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebio577xxEA1x1Text 4 } -- wtWebio577xxEA1x1TimeZone Group ---------------------------- wtWebio577xxEA1x1TzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebio577xxEA1x1TimeZone 1 } wtWebio577xxEA1x1TzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebio577xxEA1x1TimeZone 2 } wtWebio577xxEA1x1TzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebio577xxEA1x1TimeZone 3 } wtWebio577xxEA1x1StTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebio577xxEA1x1TimeZone 4 } wtWebio577xxEA1x1StTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebio577xxEA1x1TimeZone 5 } wtWebio577xxEA1x1StTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebio577xxEA1x1TimeZone 6 } wtWebio577xxEA1x1StTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA1x1StartMonth-January(1), wtWebio577xxEA1x1StartMonth-February(2), wtWebio577xxEA1x1StartMonth-March(3), wtWebio577xxEA1x1StartMonth-April(4), wtWebio577xxEA1x1StartMonth-May(5), wtWebio577xxEA1x1StartMonth-June(6), wtWebio577xxEA1x1StartMonth-July(7), wtWebio577xxEA1x1StartMonth-August(8), wtWebio577xxEA1x1StartMonth-September(9), wtWebio577xxEA1x1StartMonth-October(10), wtWebio577xxEA1x1StartMonth-November(11), wtWebio577xxEA1x1StartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebio577xxEA1x1TimeZone 7 } wtWebio577xxEA1x1StTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA1x1StartMode-first(1), wtWebio577xxEA1x1StartMode-second(2), wtWebio577xxEA1x1StartMode-third(3), wtWebio577xxEA1x1StartMode-fourth(4), wtWebio577xxEA1x1StartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebio577xxEA1x1TimeZone 8 } wtWebio577xxEA1x1StTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA1x1StartWday-Sunday(1), wtWebio577xxEA1x1StartWday-Monday(2), wtWebio577xxEA1x1StartWday-Tuesday(3), wtWebio577xxEA1x1StartWday-Thursday(4), wtWebio577xxEA1x1StartWday-Wednesday(5), wtWebio577xxEA1x1StartWday-Friday(6), wtWebio577xxEA1x1StartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebio577xxEA1x1TimeZone 9 } wtWebio577xxEA1x1StTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebio577xxEA1x1TimeZone 10 } wtWebio577xxEA1x1StTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebio577xxEA1x1TimeZone 11 } wtWebio577xxEA1x1StTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA1x1StopMonth-January(1), wtWebio577xxEA1x1StopMonth-February(2), wtWebio577xxEA1x1StopMonth-March(3), wtWebio577xxEA1x1StopMonth-April(4), wtWebio577xxEA1x1StopMonth-May(5), wtWebio577xxEA1x1StopMonth-June(6), wtWebio577xxEA1x1StopMonth-July(7), wtWebio577xxEA1x1StopMonth-August(8), wtWebio577xxEA1x1StopMonth-September(9), wtWebio577xxEA1x1StopMonth-October(10), wtWebio577xxEA1x1StopMonth-November(11), wtWebio577xxEA1x1StopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebio577xxEA1x1TimeZone 12 } wtWebio577xxEA1x1StTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA1x1StopMode-first(1), wtWebio577xxEA1x1StopMode-second(2), wtWebio577xxEA1x1StopMode-third(3), wtWebio577xxEA1x1StopMode-fourth(4), wtWebio577xxEA1x1StopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebio577xxEA1x1TimeZone 13 } wtWebio577xxEA1x1StTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA1x1StopWday-Sunday(1), wtWebio577xxEA1x1StopWday-Monday(2), wtWebio577xxEA1x1StopWday-Tuesday(3), wtWebio577xxEA1x1StopWday-Thursday(4), wtWebio577xxEA1x1StopWday-Wednesday(5), wtWebio577xxEA1x1StopWday-Friday(6), wtWebio577xxEA1x1StopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebio577xxEA1x1TimeZone 14 } wtWebio577xxEA1x1StTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebio577xxEA1x1TimeZone 15 } wtWebio577xxEA1x1StTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebio577xxEA1x1TimeZone 16 } -- wtWebio577xxEA1x1TimeServer Group ---------------------------- wtWebio577xxEA1x1TimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebio577xxEA1x1TimeServer 1 } wtWebio577xxEA1x1TimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebio577xxEA1x1TimeServer 2 } wtWebio577xxEA1x1TsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebio577xxEA1x1TimeServer 3 } wtWebio577xxEA1x1TsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebio577xxEA1x1TimeServer 4 } -- wtWebio577xxEA1x1DeviceClock Group ---------------------------- wtWebio577xxEA1x1ClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebio577xxEA1x1DeviceClock 1 } wtWebio577xxEA1x1ClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebio577xxEA1x1DeviceClock 2 } wtWebio577xxEA1x1ClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebio577xxEA1x1DeviceClock 3 } wtWebio577xxEA1x1ClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA1x1ClockMonth-January(1), wtWebio577xxEA1x1ClockMonth-February(2), wtWebio577xxEA1x1ClockMonth-March(3), wtWebio577xxEA1x1ClockMonth-April(4), wtWebio577xxEA1x1ClockMonth-May(5), wtWebio577xxEA1x1ClockMonth-June(6), wtWebio577xxEA1x1ClockMonth-July(7), wtWebio577xxEA1x1ClockMonth-August(8), wtWebio577xxEA1x1ClockMonth-September(9), wtWebio577xxEA1x1ClockMonth-October(10), wtWebio577xxEA1x1ClockMonth-November(11), wtWebio577xxEA1x1ClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebio577xxEA1x1DeviceClock 4 } wtWebio577xxEA1x1ClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebio577xxEA1x1DeviceClock 5 } -- wtWebio577xxEA1x1Network Group ------------------------ wtWebio577xxEA1x1IpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebio577xxEA1x1Network 1 } wtWebio577xxEA1x1SubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebio577xxEA1x1Network 2 } wtWebio577xxEA1x1Gateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebio577xxEA1x1Network 3 } wtWebio577xxEA1x1DnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebio577xxEA1x1Network 4 } wtWebio577xxEA1x1DnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebio577xxEA1x1Network 5 } wtWebio577xxEA1x1AddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebio577xxEA1x1Network 6 } -- wtWebio577xxEA1x1HTTP Group -------------------------------- wtWebio577xxEA1x1Startup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebio577xxEA1x1HTTP 1 } wtWebio577xxEA1x1GetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebio577xxEA1x1HTTP 2 } wtWebio577xxEA1x1HttpInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebio577xxEA1x1HTTP 3 } wtWebio577xxEA1x1HttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebio577xxEA1x1HTTP 4 } -- wtWebio577xxEA1x1Mail Group -------------------------------- wtWebio577xxEA1x1MailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebio577xxEA1x1Mail 1 } wtWebio577xxEA1x1MailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebio577xxEA1x1Mail 2 } wtWebio577xxEA1x1MailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebio577xxEA1x1Mail 3 } wtWebio577xxEA1x1MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebio577xxEA1x1Mail 4 } wtWebio577xxEA1x1MailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebio577xxEA1x1Mail 5 } wtWebio577xxEA1x1MailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebio577xxEA1x1Mail 6 } wtWebio577xxEA1x1MailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebio577xxEA1x1Mail 7 } wtWebio577xxEA1x1MailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebio577xxEA1x1Mail 8 } -- wtWebio577xxEA1x1Snmp Group -------------------------------- wtWebio577xxEA1x1SnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebio577xxEA1x1SNMP 1 } wtWebio577xxEA1x1SnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebio577xxEA1x1SNMP 2 } wtWebio577xxEA1x1SnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebio577xxEA1x1SNMP 3 } wtWebio577xxEA1x1SnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebio577xxEA1x1SNMP 4 } wtWebio577xxEA1x1SnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtWebio577xxEA1x1SNMP 5 } wtWebio577xxEA1x1SnmpSystemTrapManagerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the system trap." ::= { wtWebio577xxEA1x1SNMP 6 } -- wtWebio577xxEA1x1UDP Group -------------------------------- wtWebio577xxEA1x1UdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebio577xxEA1x1UDP 1 } wtWebio577xxEA1x1UdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebio577xxEA1x1UDP 2 } wtWebio577xxEA1x1UdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebio577xxEA1x1UDP 3 } -- wtWebio577xxEA1x1Binary Group -------------------------------- wtWebio577xxEA1x1BinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebio577xxEA1x1Binary 1 } -- Binary Interface Table wtWebio577xxEA1x1BinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA1x1BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebio577xxEA1x1Binary 2 } wtWebio577xxEA1x1BinaryIfEntry OBJECT-TYPE SYNTAX WtWebio577xxEA1x1BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebio577xxEA1x1BinaryModeNo } ::= { wtWebio577xxEA1x1BinaryIfTable 1 } WtWebio577xxEA1x1BinaryIfEntry ::= SEQUENCE { wtWebio577xxEA1x1BinaryModeNo INTEGER } wtWebio577xxEA1x1BinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebio577xxEA1x1BinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebio577xxEA1x1BinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA1x1BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebio577xxEA1x1Binary 3 } wtWebio577xxEA1x1BinaryEntry OBJECT-TYPE SYNTAX WtWebio577xxEA1x1BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebio577xxEA1x1BinaryModeNo } ::= { wtWebio577xxEA1x1BinaryTable 1 } WtWebio577xxEA1x1BinaryEntry ::= SEQUENCE { wtWebio577xxEA1x1BinaryOperationMode OCTET STRING, wtWebio577xxEA1x1BinaryTcpServerLocalPort INTEGER, wtWebio577xxEA1x1BinaryTcpServerInputTrigger OCTET STRING, wtWebio577xxEA1x1BinaryTcpServerApplicationMode OCTET STRING, wtWebio577xxEA1x1BinaryTcpClientLocalPort INTEGER, wtWebio577xxEA1x1BinaryTcpClientServerPort INTEGER, wtWebio577xxEA1x1BinaryTcpClientServerIpAddr OCTET STRING, wtWebio577xxEA1x1BinaryTcpClientServerPassword OCTET STRING, wtWebio577xxEA1x1BinaryTcpClientInactivity INTEGER, wtWebio577xxEA1x1BinaryTcpClientInputTrigger OCTET STRING, wtWebio577xxEA1x1BinaryTcpClientInterval INTEGER, wtWebio577xxEA1x1BinaryTcpClientApplicationMode OCTET STRING, wtWebio577xxEA1x1BinaryUdpPeerLocalPort INTEGER, wtWebio577xxEA1x1BinaryUdpPeerRemotePort INTEGER, wtWebio577xxEA1x1BinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebio577xxEA1x1BinaryUdpPeerInputTrigger OCTET STRING, wtWebio577xxEA1x1BinaryUdpPeerInterval INTEGER, wtWebio577xxEA1x1BinaryUdpPeerApplicationMode OCTET STRING, wtWebio577xxEA1x1BinaryConnectedPort INTEGER, wtWebio577xxEA1x1BinaryConnectedIpAddr IpAddress, wtWebio577xxEA1x1BinaryTcpServerClientHttpPort INTEGER, wtWebio577xxEA1x1BinaryTcpClientServerHttpPort INTEGER, wtWebio577xxEA1x1BinaryTcpClientServerUserName OCTET STRING } wtWebio577xxEA1x1BinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebio577xxEA1x1BinaryEntry 1 } wtWebio577xxEA1x1BinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebio577xxEA1x1BinaryEntry 2 } wtWebio577xxEA1x1BinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebio577xxEA1x1BinaryEntry 3 } wtWebio577xxEA1x1BinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebio577xxEA1x1BinaryEntry 4 } wtWebio577xxEA1x1BinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebio577xxEA1x1BinaryEntry 5 } wtWebio577xxEA1x1BinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebio577xxEA1x1BinaryEntry 6 } wtWebio577xxEA1x1BinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebio577xxEA1x1BinaryEntry 7 } wtWebio577xxEA1x1BinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebio577xxEA1x1BinaryEntry 8 } wtWebio577xxEA1x1BinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebio577xxEA1x1BinaryEntry 9 } wtWebio577xxEA1x1BinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebio577xxEA1x1BinaryEntry 10 } wtWebio577xxEA1x1BinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebio577xxEA1x1BinaryEntry 11 } wtWebio577xxEA1x1BinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebio577xxEA1x1BinaryEntry 12 } wtWebio577xxEA1x1BinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebio577xxEA1x1BinaryEntry 13 } wtWebio577xxEA1x1BinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebio577xxEA1x1BinaryEntry 14 } wtWebio577xxEA1x1BinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebio577xxEA1x1BinaryEntry 15 } wtWebio577xxEA1x1BinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebio577xxEA1x1BinaryEntry 16 } wtWebio577xxEA1x1BinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebio577xxEA1x1BinaryEntry 17 } wtWebio577xxEA1x1BinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebio577xxEA1x1BinaryEntry 18 } wtWebio577xxEA1x1BinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebio577xxEA1x1BinaryEntry 19 } wtWebio577xxEA1x1BinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebio577xxEA1x1BinaryEntry 20 } wtWebio577xxEA1x1BinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebio577xxEA1x1BinaryEntry 21 } wtWebio577xxEA1x1BinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebio577xxEA1x1BinaryEntry 22 } wtWebio577xxEA1x1BinaryTcpClientServerUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "User Name to login at the remote server, if authentication needed." ::= { wtWebio577xxEA1x1BinaryEntry 23 } -- wtWebio577xxEA1x1Syslog Group -------------------------------- wtWebio577xxEA1x1SyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebio577xxEA1x1Syslog 1 } wtWebio577xxEA1x1SyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebio577xxEA1x1Syslog 2 } wtWebio577xxEA1x1SyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebio577xxEA1x1Syslog 3 } wtWebio577xxEA1x1SyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebio577xxEA1x1Syslog 4 } -- wtWebio577xxEA1x1FTP Group -------------------------------- wtWebio577xxEA1x1FTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebio577xxEA1x1FTP 1 } wtWebio577xxEA1x1FTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebio577xxEA1x1FTP 2 } wtWebio577xxEA1x1FTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebio577xxEA1x1FTP 3 } wtWebio577xxEA1x1FTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebio577xxEA1x1FTP 4 } wtWebio577xxEA1x1FTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebio577xxEA1x1FTP 5 } wtWebio577xxEA1x1FTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebio577xxEA1x1FTP 6 } wtWebio577xxEA1x1FTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebio577xxEA1x1FTP 7 } -- wtWebio577xxEA1x1MQTT Group -------------------------------- wtWebio577xxEA1x1MQTTEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 7 schaltet MQTT frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0-6: ungenutzt Bit 7 : MQTT enable" ::= { wtWebio577xxEA1x1MQTT 1 } wtWebio577xxEA1x1MQTTBrockerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP-address of the MQTT-Server." ::= { wtWebio577xxEA1x1MQTT 2 } wtWebio577xxEA1x1MQTTUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT login user name." ::= { wtWebio577xxEA1x1MQTT 3 } wtWebio577xxEA1x1MQTTPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT login password." ::= { wtWebio577xxEA1x1MQTT 4 } wtWebio577xxEA1x1MQTTLocalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Local port number." ::= { wtWebio577xxEA1x1MQTT 5 } wtWebio577xxEA1x1MQTTBrokerServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Server port number." ::= { wtWebio577xxEA1x1MQTT 6 } wtWebio577xxEA1x1MQTTInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Ping intervall, if no data has to be send: time in seconds." ::= { wtWebio577xxEA1x1MQTT 7 } wtWebio577xxEA1x1MQTTLastWillEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activate MQTT LastWill message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will enable" ::= { wtWebio577xxEA1x1MQTT 8 } wtWebio577xxEA1x1MQTTLastWillTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will Topic." ::= { wtWebio577xxEA1x1MQTT 9 } wtWebio577xxEA1x1MQTTLastWillMsg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will message." ::= { wtWebio577xxEA1x1MQTT 10 } wtWebio577xxEA1x1MQTTLastWillQoS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded MQTT Publish QoS: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused" ::= { wtWebio577xxEA1x1MQTT 11 } wtWebio577xxEA1x1MQTTLastWillRetain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded MQTT Publish Retain properties: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused" ::= { wtWebio577xxEA1x1MQTT 12 } wtWebio577xxEA1x1MQTTLastWillConnectEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activate MQTT LastWill Connect message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will connect message enable" ::= { wtWebio577xxEA1x1MQTT 13 } wtWebio577xxEA1x1MQTTLastWillConnectMsg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will Connect message will be send with the QoS and Retain settings of the LastWill message." ::= { wtWebio577xxEA1x1MQTT 14 } -- wtWebio577xxEA1x1REST Group -------------------------------- wtWebio577xxEA1x1RESTEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activates REST: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : REST enable" ::= { wtWebio577xxEA1x1REST 1 } wtWebio577xxEA1x1RESTDigestAuthEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activates Digest-Authentification: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Digest Auth enable" ::= { wtWebio577xxEA1x1REST 2 } -- wtWebio577xxEA1x1OutputMode Group -------------------------------- -- OutputMode Table wtWebio577xxEA1x1OutputModeTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA1x1OutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of output mode configurations dependent on the output indices." ::= { wtWebio577xxEA1x1OutputMode 1 } wtWebio577xxEA1x1OutputModeEntry OBJECT-TYPE SYNTAX WtWebio577xxEA1x1OutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output mode configurations of the individual outputs." INDEX { wtWebio577xxEA1x1OutputNo } ::= { wtWebio577xxEA1x1OutputModeTable 1 } WtWebio577xxEA1x1OutputModeEntry ::= SEQUENCE { wtWebio577xxEA1x1OutputModeBit OCTET STRING } wtWebio577xxEA1x1OutputModeBit OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: Bit 7 : unused Bit 6 : unused Bit 5 : unused Bit 4 : unused Bit 3 : unused Bit 2 : unused Bit 1 : REST Bit 0 : AJAX OCTET 3: Bit 7 : Web Alarm Bit 6 : ASCII Socket Bit 5 : Time Switch Bit 4 : Logic Bit 3 : Binary 9 Bit 2 : Binary 8 Bit 1 : Binary 7 Bit 0 : Binary 6 OCTET 4: Bit 7 : Binary 5 Bit 6 : Binary 4 Bit 5 : Binary 3 Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebio577xxEA1x1OutputModeEntry 1 } wtWebio577xxEA1x1SafetyTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined." ::= { wtWebio577xxEA1x1OutputMode 2 } wtWebio577xxEA1x1LoadControlEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Here the function of automatic load control can be enabled. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Load Control enable" ::= { wtWebio577xxEA1x1OutputMode 3 } -- wtWebio577xxEA1x1Alarm Group ---------------------------- wtWebio577xxEA1x1AlarmCount OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebio577xxEA1x1Alarm 1 } -- Alarm Interface Table wtWebio577xxEA1x1AlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA1x1AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebio577xxEA1x1Alarm 2 } wtWebio577xxEA1x1AlarmIfEntry OBJECT-TYPE SYNTAX WtWebio577xxEA1x1AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebio577xxEA1x1AlarmNo } ::= { wtWebio577xxEA1x1AlarmIfTable 1 } WtWebio577xxEA1x1AlarmIfEntry ::= SEQUENCE { wtWebio577xxEA1x1AlarmNo INTEGER } wtWebio577xxEA1x1AlarmNo OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtWebio577xxEA1x1AlarmIfEntry 1 } -- Alarm Table wtWebio577xxEA1x1AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA1x1AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebio577xxEA1x1Alarm 3 } wtWebio577xxEA1x1AlarmEntry OBJECT-TYPE SYNTAX WtWebio577xxEA1x1AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebio577xxEA1x1AlarmNo } ::= { wtWebio577xxEA1x1AlarmTable 1 } WtWebio577xxEA1x1AlarmEntry ::= SEQUENCE { wtWebio577xxEA1x1AlarmInputTrigger OCTET STRING, wtWebio577xxEA1x1AlarmOutputTrigger OCTET STRING, wtWebio577xxEA1x1AlarmSystemTrigger OCTET STRING, wtWebio577xxEA1x1AlarmMaxCounterValue OCTET STRING, wtWebio577xxEA1x1AlarmInterval OCTET STRING, wtWebio577xxEA1x1AlarmEnable OCTET STRING, wtWebio577xxEA1x1AlarmMailAddr OCTET STRING, wtWebio577xxEA1x1AlarmMailSubject OCTET STRING, wtWebio577xxEA1x1AlarmMailText OCTET STRING, wtWebio577xxEA1x1AlarmSnmpManagerIP OCTET STRING, wtWebio577xxEA1x1AlarmSnmpTrapText OCTET STRING, wtWebio577xxEA1x1AlarmUdpIpAddr OCTET STRING, wtWebio577xxEA1x1AlarmUdpPort INTEGER, wtWebio577xxEA1x1AlarmUdpText OCTET STRING, wtWebio577xxEA1x1AlarmTcpIpAddr OCTET STRING, wtWebio577xxEA1x1AlarmTcpPort INTEGER, wtWebio577xxEA1x1AlarmTcpText OCTET STRING, wtWebio577xxEA1x1AlarmSyslogIpAddr OCTET STRING, wtWebio577xxEA1x1AlarmSyslogPort INTEGER, wtWebio577xxEA1x1AlarmSyslogText OCTET STRING, wtWebio577xxEA1x1AlarmFtpDataPort OCTET STRING, wtWebio577xxEA1x1AlarmFtpFileName OCTET STRING, wtWebio577xxEA1x1AlarmFtpText OCTET STRING, wtWebio577xxEA1x1AlarmFtpOption OCTET STRING, wtWebio577xxEA1x1AlarmTimerCron OCTET STRING, wtWebio577xxEA1x1AlarmMailReleaseSubject OCTET STRING, wtWebio577xxEA1x1AlarmMailReleaseText OCTET STRING, wtWebio577xxEA1x1AlarmSnmpTrapReleaseText OCTET STRING, wtWebio577xxEA1x1AlarmUdpReleaseText OCTET STRING, wtWebio577xxEA1x1AlarmTcpReleaseText OCTET STRING, wtWebio577xxEA1x1AlarmSyslogReleaseText OCTET STRING, wtWebio577xxEA1x1AlarmFtpReleaseText OCTET STRING, wtWebio577xxEA1x1AlarmGlobalEnable OCTET STRING, wtWebio577xxEA1x1AlarmCombinationLogic OCTET STRING, wtWebio577xxEA1x1AlarmTrgMqttTopic OCTET STRING, wtWebio577xxEA1x1AlarmTrgMqttTopicText OCTET STRING, wtWebio577xxEA1x1AlarmHttpReqAuthEnable OCTET STRING, wtWebio577xxEA1x1AlarmHttpReqAuthUser OCTET STRING, wtWebio577xxEA1x1AlarmHttpReqAuthPassword OCTET STRING, wtWebio577xxEA1x1AlarmHttpReqSetUrl OCTET STRING, wtWebio577xxEA1x1AlarmHttpReqClearUrl OCTET STRING, wtWebio577xxEA1x1AlarmHttpReqServerPort INTEGER, wtWebio577xxEA1x1AlarmMqttTopicPath OCTET STRING, wtWebio577xxEA1x1AlarmMqttTopicSetTopic OCTET STRING, wtWebio577xxEA1x1AlarmMqttTopicClear OCTET STRING, wtWebio577xxEA1x1AlarmSetOutputsOwn OCTET STRING, wtWebio577xxEA1x1AlarmSetOutputsServerIp OCTET STRING, wtWebio577xxEA1x1AlarmSetOutputsServerPort INTEGER, wtWebio577xxEA1x1AlarmSetOutputsServerPassword OCTET STRING, wtWebio577xxEA1x1AlarmSetOutputsServerOutputs OCTET STRING, wtWebio577xxEA1x1AlarmSetOutputsDest OCTET STRING, wtWebio577xxEA1x1AlarmSnmpManagerPort INTEGER, wtWebio577xxEA1x1AlarmMqttQoS OCTET STRING, wtWebio577xxEA1x1AlarmMqttRetain OCTET STRING } wtWebio577xxEA1x1AlarmInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital inputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital inputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1" ::= { wtWebio577xxEA1x1AlarmEntry 1 } wtWebio577xxEA1x1AlarmOutputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1" ::= { wtWebio577xxEA1x1AlarmEntry 2 } wtWebio577xxEA1x1AlarmSystemTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control" ::= { wtWebio577xxEA1x1AlarmEntry 3 } wtWebio577xxEA1x1AlarmMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebio577xxEA1x1AlarmInputTrigger are not considered." ::= { wtWebio577xxEA1x1AlarmEntry 4 } wtWebio577xxEA1x1AlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebio577xxEA1x1AlarmEntry 5 } wtWebio577xxEA1x1AlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Bit 0: UDP enable Bit1-7: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable Bit 3: Syslog Messages enable Bit 4: FTP enable Bit 5: HTTP Request enable Bit 6 MQTT Publish enable Bit 7: Set Outputs" ::= { wtWebio577xxEA1x1AlarmEntry 6 } wtWebio577xxEA1x1AlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebio577xxEA1x1AlarmEntry 7 } wtWebio577xxEA1x1AlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebio577xxEA1x1AlarmEntry 8 } wtWebio577xxEA1x1AlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebio577xxEA1x1AlarmEntry 9 } wtWebio577xxEA1x1AlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebio577xxEA1x1AlarmEntry 10 } wtWebio577xxEA1x1AlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebio577xxEA1x1AlarmEntry 11 } wtWebio577xxEA1x1AlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebio577xxEA1x1AlarmEntry 12 } wtWebio577xxEA1x1AlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebio577xxEA1x1AlarmEntry 13 } wtWebio577xxEA1x1AlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebio577xxEA1x1AlarmEntry 14 } wtWebio577xxEA1x1AlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebio577xxEA1x1AlarmEntry 15 } wtWebio577xxEA1x1AlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebio577xxEA1x1AlarmEntry 16 } wtWebio577xxEA1x1AlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebio577xxEA1x1AlarmEntry 17 } wtWebio577xxEA1x1AlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebio577xxEA1x1AlarmEntry 18 } wtWebio577xxEA1x1AlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebio577xxEA1x1AlarmEntry 19 } wtWebio577xxEA1x1AlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebio577xxEA1x1AlarmEntry 20 } wtWebio577xxEA1x1AlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebio577xxEA1x1AlarmEntry 21 } wtWebio577xxEA1x1AlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebio577xxEA1x1AlarmEntry 22 } wtWebio577xxEA1x1AlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebio577xxEA1x1AlarmEntry 23 } wtWebio577xxEA1x1AlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebio577xxEA1x1AlarmEntry 24 } wtWebio577xxEA1x1AlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebio577xxEA1x1AlarmEntry 25 } wtWebio577xxEA1x1AlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebio577xxEA1x1AlarmEntry 26 } wtWebio577xxEA1x1AlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebio577xxEA1x1AlarmEntry 27 } wtWebio577xxEA1x1AlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebio577xxEA1x1AlarmEntry 28 } wtWebio577xxEA1x1AlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebio577xxEA1x1AlarmEntry 29 } wtWebio577xxEA1x1AlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebio577xxEA1x1AlarmEntry 30 } wtWebio577xxEA1x1AlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebio577xxEA1x1AlarmEntry 31 } wtWebio577xxEA1x1AlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebio577xxEA1x1AlarmEntry 32 } wtWebio577xxEA1x1AlarmGlobalEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm activation: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Alarm enable" ::= { wtWebio577xxEA1x1AlarmEntry 34 } wtWebio577xxEA1x1AlarmCombinationLogic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm activation:: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : OR Bit 0 : AND" ::= { wtWebio577xxEA1x1AlarmEntry 58 } wtWebio577xxEA1x1AlarmTrgMqttTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT subscribe topic." ::= { wtWebio577xxEA1x1AlarmEntry 59 } wtWebio577xxEA1x1AlarmTrgMqttTopicText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Receiving this text from the MQTT Broker, Alarm will be triggered." ::= { wtWebio577xxEA1x1AlarmEntry 60 } wtWebio577xxEA1x1AlarmHttpReqAuthEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm activation: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable" ::= { wtWebio577xxEA1x1AlarmEntry 61 } wtWebio577xxEA1x1AlarmHttpReqAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: User" ::= { wtWebio577xxEA1x1AlarmEntry 62 } wtWebio577xxEA1x1AlarmHttpReqAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Password" ::= { wtWebio577xxEA1x1AlarmEntry 63 } wtWebio577xxEA1x1AlarmHttpReqSetUrl OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Set URL" ::= { wtWebio577xxEA1x1AlarmEntry 64 } wtWebio577xxEA1x1AlarmHttpReqClearUrl OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Clear URL" ::= { wtWebio577xxEA1x1AlarmEntry 65 } wtWebio577xxEA1x1AlarmHttpReqServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Server Port" ::= { wtWebio577xxEA1x1AlarmEntry 66 } wtWebio577xxEA1x1AlarmMqttTopicPath OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic path" ::= { wtWebio577xxEA1x1AlarmEntry 67 } wtWebio577xxEA1x1AlarmMqttTopicSetTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic SET message" ::= { wtWebio577xxEA1x1AlarmEntry 68 } wtWebio577xxEA1x1AlarmMqttTopicClear OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic CLEAR message" ::= { wtWebio577xxEA1x1AlarmEntry 69 } wtWebio577xxEA1x1AlarmSetOutputsOwn OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0: Mask for digital outputs 0 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0: Level of digital outputs 0 OCTETS 9-12 are unused." ::= { wtWebio577xxEA1x1AlarmEntry 70 } wtWebio577xxEA1x1AlarmSetOutputsServerIp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Outputs: Server IP Address" ::= { wtWebio577xxEA1x1AlarmEntry 71 } wtWebio577xxEA1x1AlarmSetOutputsServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Set Outputs: Server Port" ::= { wtWebio577xxEA1x1AlarmEntry 72 } wtWebio577xxEA1x1AlarmSetOutputsServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Outputs: Server Pasword" ::= { wtWebio577xxEA1x1AlarmEntry 73 } wtWebio577xxEA1x1AlarmSetOutputsServerOutputs OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0: Mask for digital outputs 0 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0: Level of digital outputs 0 OCTETS 9-12 are unused." ::= { wtWebio577xxEA1x1AlarmEntry 74 } wtWebio577xxEA1x1AlarmSetOutputsDest OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : set outputs of remote server. Bit 0 : set outputs of this WEB-IO" ::= { wtWebio577xxEA1x1AlarmEntry 75 } wtWebio577xxEA1x1AlarmSnmpManagerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebio577xxEA1x1AlarmEntry 76 } wtWebio577xxEA1x1AlarmMqttQoS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused" ::= { wtWebio577xxEA1x1AlarmEntry 77 } wtWebio577xxEA1x1AlarmMqttRetain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused" ::= { wtWebio577xxEA1x1AlarmEntry 78 } -- wtWebio577xxEA1x1LoadControl ---------------------------- wtWebio577xxEA1x1LoadControlView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Here the result of automatic load control can be read. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1." ::= { wtWebio577xxEA1x1Alarm 4 } wtWebio577xxEA1x1LCShutDownView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Here the result of the automatic load control shut down can be read. All outputs remain switched of, until a zero is written into this variable. But previously all loads should be inspected. High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason. If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair. All controlled output could be identified reading the variable wtWebio577xxEA1x1LoadControlEnable. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1." ::= { wtWebio577xxEA1x1Alarm 5 } -- wtWebio577xxEA1x1Ports Group ---------------------------- -- Input Port Table wtWebio577xxEA1x1InputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA1x1InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebio577xxEA1x1Ports 1 } wtWebio577xxEA1x1InputPortEntry OBJECT-TYPE SYNTAX WtWebio577xxEA1x1InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebio577xxEA1x1InputNo } ::= { wtWebio577xxEA1x1InputPortTable 1 } WtWebio577xxEA1x1InputPortEntry ::= SEQUENCE { wtWebio577xxEA1x1PortInputName OCTET STRING, wtWebio577xxEA1x1PortInputText OCTET STRING, wtWebio577xxEA1x1PortInputMode OCTET STRING, wtWebio577xxEA1x1PortInputFilter INTEGER, wtWebio577xxEA1x1PortInputBicountPulsePolarity OCTET STRING, wtWebio577xxEA1x1PortInputBicountInactivTimeout INTEGER } wtWebio577xxEA1x1PortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebio577xxEA1x1InputPortEntry 1 } wtWebio577xxEA1x1PortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebio577xxEA1x1InputPortEntry 2 } wtWebio577xxEA1x1PortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. Selection for input 0-1: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Bidirectional counter enable Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable" ::= { wtWebio577xxEA1x1InputPortEntry 3 } wtWebio577xxEA1x1PortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebio577xxEA1x1InputPortEntry 4 } wtWebio577xxEA1x1PortInputBicountPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebio577xxEA1x1InputPortEntry 5 } wtWebio577xxEA1x1PortInputBicountInactivTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored." ::= { wtWebio577xxEA1x1InputPortEntry 6 } -- Output Port Table wtWebio577xxEA1x1OutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA1x1OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtWebio577xxEA1x1Ports 2 } wtWebio577xxEA1x1OutputPortEntry OBJECT-TYPE SYNTAX WtWebio577xxEA1x1OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtWebio577xxEA1x1OutputNo } ::= { wtWebio577xxEA1x1OutputPortTable 1 } WtWebio577xxEA1x1OutputPortEntry ::= SEQUENCE { wtWebio577xxEA1x1PortOutputName OCTET STRING, wtWebio577xxEA1x1PortOutputText OCTET STRING, wtWebio577xxEA1x1PortOutputGroupMode OCTET STRING, wtWebio577xxEA1x1PortOutputSafetyState OCTET STRING, wtWebio577xxEA1x1PortLogicInputMask OCTET STRING, wtWebio577xxEA1x1PortLogicInputInverter OCTET STRING, wtWebio577xxEA1x1PortLogicFunction OCTET STRING, wtWebio577xxEA1x1PortLogicOutputInverter OCTET STRING, wtWebio577xxEA1x1PortPulseDuration INTEGER, wtWebio577xxEA1x1PortPulsePolarity OCTET STRING } wtWebio577xxEA1x1PortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtWebio577xxEA1x1OutputPortEntry 1 } wtWebio577xxEA1x1PortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtWebio577xxEA1x1OutputPortEntry 2 } wtWebio577xxEA1x1PortOutputGroupMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one ouput bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for ouputs 0-1: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : ouputs 0,1 disconnected (default) Bit 1 : ouputs 0+1 connected" ::= { wtWebio577xxEA1x1OutputPortEntry 3 } wtWebio577xxEA1x1PortOutputSafetyState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output" ::= { wtWebio577xxEA1x1OutputPortEntry 4 } wtWebio577xxEA1x1PortLogicInputMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebio577xxEA1x1PortLogicInputMask) 2. Inverting inputs if necessary (wtWebio577xxEA1x1PortLogicInputInverter) 3. Logical combination (wtWebio577xxEA1x1PortLogicFunction) 4. Inverting the result if necessary (wtWebio577xxEA1x1PortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1" ::= { wtWebio577xxEA1x1OutputPortEntry 5 } wtWebio577xxEA1x1PortLogicInputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1" ::= { wtWebio577xxEA1x1OutputPortEntry 6 } wtWebio577xxEA1x1PortLogicFunction OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused" ::= { wtWebio577xxEA1x1OutputPortEntry 7 } wtWebio577xxEA1x1PortLogicOutputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused" ::= { wtWebio577xxEA1x1OutputPortEntry 8 } wtWebio577xxEA1x1PortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtWebio577xxEA1x1OutputPortEntry 9 } wtWebio577xxEA1x1PortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtWebio577xxEA1x1PortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebio577xxEA1x1OutputPortEntry 10 } -- wtWebio577xxEA1x1Manufact Group ---------------------------- wtWebio577xxEA1x1MfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebio577xxEA1x1Manufact 1 } wtWebio577xxEA1x1MfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebio577xxEA1x1Manufact 2 } wtWebio577xxEA1x1MfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebio577xxEA1x1Manufact 3 } wtWebio577xxEA1x1MfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebio577xxEA1x1Manufact 4 } wtWebio577xxEA1x1MfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebio577xxEA1x1Manufact 5 } -- wtWebio577xxEA1x1Diag Group ---------------------------- wtWebio577xxEA1x1DiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebio577xxEA1x1Diag 1 } wtWebio577xxEA1x1DiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebio577xxEA1x1Diag 2 } wtWebio577xxEA1x1DiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebio577xxEA1x1DiagErrorMessage. Errors are numbered from 1 to wtWebio577xxEA1x1DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebio577xxEA1x1DiagErrorMessage." ::= { wtWebio577xxEA1x1Diag 3 } wtWebio577xxEA1x1DiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebio577xxEA1x1DiagErrorIndex as an index, the appropriate message is available." ::= { wtWebio577xxEA1x1Diag 4 } wtWebio577xxEA1x1DiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebio577xxEA1x1Diag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebio577xxEA1x1Alert1 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtWebio577xxEA1x1Alert2 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtWebio577xxEA1x1Alert3 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtWebio577xxEA1x1Alert4 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtWebio577xxEA1x1Alert5 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtWebio577xxEA1x1Alert6 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtWebio577xxEA1x1Alert7 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtWebio577xxEA1x1Alert8 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtWebio577xxEA1x1Alert9 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtWebio577xxEA1x1Alert10 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtWebio577xxEA1x1Alert11 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtWebio577xxEA1x1Alert12 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtWebio577xxEA1x1Alert13 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebio577xxEA1x1Alert14 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebio577xxEA1x1Alert15 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebio577xxEA1x1Alert16 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebio577xxEA1x1Alert17 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebio577xxEA1x1Alert18 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebio577xxEA1x1Alert19 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebio577xxEA1x1Alert20 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebio577xxEA1x1Alert21 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtWebio577xxEA1x1Alert22 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtWebio577xxEA1x1Alert23 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebio577xxEA1x1Alert24 TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebio577xxEA1x1AlertDiag TRAP-TYPE ENTERPRISE wtWebio577xxEA1x1 VARIABLES { wtWebio577xxEA1x1DiagErrorIndex, wtWebio577xxEA1x1DiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebio577xxEA2x2InOut Group ------------------------ wtWebio577xxEA2x2Inputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtWebio577xxEA2x2InOut 1 } wtWebio577xxEA2x2Outputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent outputs." ::= { wtWebio577xxEA2x2InOut 2 } -- Input Interface Table wtWebio577xxEA2x2InputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA2x2InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebio577xxEA2x2InOut 3 } wtWebio577xxEA2x2InputEntry OBJECT-TYPE SYNTAX WtWebio577xxEA2x2InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtWebio577xxEA2x2InputNo } ::= { wtWebio577xxEA2x2InputTable 1 } WtWebio577xxEA2x2InputEntry ::= SEQUENCE { wtWebio577xxEA2x2InputNo INTEGER, wtWebio577xxEA2x2InputCounter INTEGER, wtWebio577xxEA2x2InputCounterClear INTEGER, wtWebio577xxEA2x2InputState INTEGER } wtWebio577xxEA2x2InputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebio577xxEA2x2InputEntry 1 } wtWebio577xxEA2x2InputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebio577xxEA2x2InputEntry 2 } wtWebio577xxEA2x2InputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtWebio577xxEA2x2InputEntry 3 } wtWebio577xxEA2x2InputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of a single input bit, 0-OFF, 1-ON." ::= { wtWebio577xxEA2x2InputEntry 4 } wtWebio577xxEA2x2InputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1" ::= { wtWebio577xxEA2x2InOut 4 } -- Output Interface Table wtWebio577xxEA2x2OutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA2x2OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtWebio577xxEA2x2InOut 5 } wtWebio577xxEA2x2OutputEntry OBJECT-TYPE SYNTAX WtWebio577xxEA2x2OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtWebio577xxEA2x2OutputNo } ::= { wtWebio577xxEA2x2OutputTable 1 } WtWebio577xxEA2x2OutputEntry ::= SEQUENCE { wtWebio577xxEA2x2OutputNo INTEGER, wtWebio577xxEA2x2OutputState INTEGER } wtWebio577xxEA2x2OutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtWebio577xxEA2x2OutputEntry 1 } wtWebio577xxEA2x2OutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of a single output bit, 0-OFF, 1-ON." ::= { wtWebio577xxEA2x2OutputEntry 2 } wtWebio577xxEA2x2OutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt" ::= { wtWebio577xxEA2x2InOut 6 } wtWebio577xxEA2x2SetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1" ::= { wtWebio577xxEA2x2InOut 7 } -- wtWebio577xxEA2x2SessCntrl Group -------------------------------- wtWebio577xxEA2x2SessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebio577xxEA2x2SessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebio577xxEA2x2SessCntrl 1 } wtWebio577xxEA2x2SessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebio577xxEA2x2SessCntrl 2 } wtWebio577xxEA2x2SessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebio577xxEA2x2SessCntrl 3 } wtWebio577xxEA2x2SessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebio577xxEA2x2SessCntrl 4 } wtWebio577xxEA2x2SessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebio577xxEA2x2SessCntrl 5 } -- wtWebio577xxEA2x2Text Group ------------------------ wtWebio577xxEA2x2DeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebio577xxEA2x2Text 1 } wtWebio577xxEA2x2DeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebio577xxEA2x2Text 2 } wtWebio577xxEA2x2DeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebio577xxEA2x2Text 3 } wtWebio577xxEA2x2DeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebio577xxEA2x2Text 4 } -- wtWebio577xxEA2x2TimeZone Group ---------------------------- wtWebio577xxEA2x2TzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebio577xxEA2x2TimeZone 1 } wtWebio577xxEA2x2TzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebio577xxEA2x2TimeZone 2 } wtWebio577xxEA2x2TzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebio577xxEA2x2TimeZone 3 } wtWebio577xxEA2x2StTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebio577xxEA2x2TimeZone 4 } wtWebio577xxEA2x2StTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebio577xxEA2x2TimeZone 5 } wtWebio577xxEA2x2StTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebio577xxEA2x2TimeZone 6 } wtWebio577xxEA2x2StTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA2x2StartMonth-January(1), wtWebio577xxEA2x2StartMonth-February(2), wtWebio577xxEA2x2StartMonth-March(3), wtWebio577xxEA2x2StartMonth-April(4), wtWebio577xxEA2x2StartMonth-May(5), wtWebio577xxEA2x2StartMonth-June(6), wtWebio577xxEA2x2StartMonth-July(7), wtWebio577xxEA2x2StartMonth-August(8), wtWebio577xxEA2x2StartMonth-September(9), wtWebio577xxEA2x2StartMonth-October(10), wtWebio577xxEA2x2StartMonth-November(11), wtWebio577xxEA2x2StartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebio577xxEA2x2TimeZone 7 } wtWebio577xxEA2x2StTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA2x2StartMode-first(1), wtWebio577xxEA2x2StartMode-second(2), wtWebio577xxEA2x2StartMode-third(3), wtWebio577xxEA2x2StartMode-fourth(4), wtWebio577xxEA2x2StartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebio577xxEA2x2TimeZone 8 } wtWebio577xxEA2x2StTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA2x2StartWday-Sunday(1), wtWebio577xxEA2x2StartWday-Monday(2), wtWebio577xxEA2x2StartWday-Tuesday(3), wtWebio577xxEA2x2StartWday-Thursday(4), wtWebio577xxEA2x2StartWday-Wednesday(5), wtWebio577xxEA2x2StartWday-Friday(6), wtWebio577xxEA2x2StartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebio577xxEA2x2TimeZone 9 } wtWebio577xxEA2x2StTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebio577xxEA2x2TimeZone 10 } wtWebio577xxEA2x2StTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebio577xxEA2x2TimeZone 11 } wtWebio577xxEA2x2StTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA2x2StopMonth-January(1), wtWebio577xxEA2x2StopMonth-February(2), wtWebio577xxEA2x2StopMonth-March(3), wtWebio577xxEA2x2StopMonth-April(4), wtWebio577xxEA2x2StopMonth-May(5), wtWebio577xxEA2x2StopMonth-June(6), wtWebio577xxEA2x2StopMonth-July(7), wtWebio577xxEA2x2StopMonth-August(8), wtWebio577xxEA2x2StopMonth-September(9), wtWebio577xxEA2x2StopMonth-October(10), wtWebio577xxEA2x2StopMonth-November(11), wtWebio577xxEA2x2StopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebio577xxEA2x2TimeZone 12 } wtWebio577xxEA2x2StTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA2x2StopMode-first(1), wtWebio577xxEA2x2StopMode-second(2), wtWebio577xxEA2x2StopMode-third(3), wtWebio577xxEA2x2StopMode-fourth(4), wtWebio577xxEA2x2StopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebio577xxEA2x2TimeZone 13 } wtWebio577xxEA2x2StTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA2x2StopWday-Sunday(1), wtWebio577xxEA2x2StopWday-Monday(2), wtWebio577xxEA2x2StopWday-Tuesday(3), wtWebio577xxEA2x2StopWday-Thursday(4), wtWebio577xxEA2x2StopWday-Wednesday(5), wtWebio577xxEA2x2StopWday-Friday(6), wtWebio577xxEA2x2StopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebio577xxEA2x2TimeZone 14 } wtWebio577xxEA2x2StTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebio577xxEA2x2TimeZone 15 } wtWebio577xxEA2x2StTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebio577xxEA2x2TimeZone 16 } -- wtWebio577xxEA2x2TimeServer Group ---------------------------- wtWebio577xxEA2x2TimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebio577xxEA2x2TimeServer 1 } wtWebio577xxEA2x2TimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebio577xxEA2x2TimeServer 2 } wtWebio577xxEA2x2TsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebio577xxEA2x2TimeServer 3 } wtWebio577xxEA2x2TsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebio577xxEA2x2TimeServer 4 } -- wtWebio577xxEA2x2DeviceClock Group ---------------------------- wtWebio577xxEA2x2ClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebio577xxEA2x2DeviceClock 1 } wtWebio577xxEA2x2ClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebio577xxEA2x2DeviceClock 2 } wtWebio577xxEA2x2ClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebio577xxEA2x2DeviceClock 3 } wtWebio577xxEA2x2ClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA2x2ClockMonth-January(1), wtWebio577xxEA2x2ClockMonth-February(2), wtWebio577xxEA2x2ClockMonth-March(3), wtWebio577xxEA2x2ClockMonth-April(4), wtWebio577xxEA2x2ClockMonth-May(5), wtWebio577xxEA2x2ClockMonth-June(6), wtWebio577xxEA2x2ClockMonth-July(7), wtWebio577xxEA2x2ClockMonth-August(8), wtWebio577xxEA2x2ClockMonth-September(9), wtWebio577xxEA2x2ClockMonth-October(10), wtWebio577xxEA2x2ClockMonth-November(11), wtWebio577xxEA2x2ClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebio577xxEA2x2DeviceClock 4 } wtWebio577xxEA2x2ClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebio577xxEA2x2DeviceClock 5 } -- wtWebio577xxEA2x2Network Group ------------------------ wtWebio577xxEA2x2IpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebio577xxEA2x2Network 1 } wtWebio577xxEA2x2SubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebio577xxEA2x2Network 2 } wtWebio577xxEA2x2Gateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebio577xxEA2x2Network 3 } wtWebio577xxEA2x2DnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebio577xxEA2x2Network 4 } wtWebio577xxEA2x2DnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebio577xxEA2x2Network 5 } wtWebio577xxEA2x2AddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebio577xxEA2x2Network 6 } -- wtWebio577xxEA2x2HTTP Group -------------------------------- wtWebio577xxEA2x2Startup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebio577xxEA2x2HTTP 1 } wtWebio577xxEA2x2GetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebio577xxEA2x2HTTP 2 } wtWebio577xxEA2x2HttpInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebio577xxEA2x2HTTP 3 } wtWebio577xxEA2x2HttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebio577xxEA2x2HTTP 4 } -- wtWebio577xxEA2x2Mail Group -------------------------------- wtWebio577xxEA2x2MailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebio577xxEA2x2Mail 1 } wtWebio577xxEA2x2MailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebio577xxEA2x2Mail 2 } wtWebio577xxEA2x2MailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebio577xxEA2x2Mail 3 } wtWebio577xxEA2x2MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebio577xxEA2x2Mail 4 } wtWebio577xxEA2x2MailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebio577xxEA2x2Mail 5 } wtWebio577xxEA2x2MailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebio577xxEA2x2Mail 6 } wtWebio577xxEA2x2MailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebio577xxEA2x2Mail 7 } wtWebio577xxEA2x2MailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebio577xxEA2x2Mail 8 } -- wtWebio577xxEA2x2Snmp Group -------------------------------- wtWebio577xxEA2x2SnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebio577xxEA2x2SNMP 1 } wtWebio577xxEA2x2SnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebio577xxEA2x2SNMP 2 } wtWebio577xxEA2x2SnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebio577xxEA2x2SNMP 3 } wtWebio577xxEA2x2SnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebio577xxEA2x2SNMP 4 } wtWebio577xxEA2x2SnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtWebio577xxEA2x2SNMP 5 } wtWebio577xxEA2x2SnmpSystemTrapManagerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the system trap." ::= { wtWebio577xxEA2x2SNMP 6 } -- wtWebio577xxEA2x2UDP Group -------------------------------- wtWebio577xxEA2x2UdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebio577xxEA2x2UDP 1 } wtWebio577xxEA2x2UdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebio577xxEA2x2UDP 2 } wtWebio577xxEA2x2UdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebio577xxEA2x2UDP 3 } -- wtWebio577xxEA2x2Binary Group -------------------------------- wtWebio577xxEA2x2BinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebio577xxEA2x2Binary 1 } -- Binary Interface Table wtWebio577xxEA2x2BinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA2x2BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebio577xxEA2x2Binary 2 } wtWebio577xxEA2x2BinaryIfEntry OBJECT-TYPE SYNTAX WtWebio577xxEA2x2BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebio577xxEA2x2BinaryModeNo } ::= { wtWebio577xxEA2x2BinaryIfTable 1 } WtWebio577xxEA2x2BinaryIfEntry ::= SEQUENCE { wtWebio577xxEA2x2BinaryModeNo INTEGER } wtWebio577xxEA2x2BinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebio577xxEA2x2BinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebio577xxEA2x2BinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA2x2BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebio577xxEA2x2Binary 3 } wtWebio577xxEA2x2BinaryEntry OBJECT-TYPE SYNTAX WtWebio577xxEA2x2BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebio577xxEA2x2BinaryModeNo } ::= { wtWebio577xxEA2x2BinaryTable 1 } WtWebio577xxEA2x2BinaryEntry ::= SEQUENCE { wtWebio577xxEA2x2BinaryOperationMode OCTET STRING, wtWebio577xxEA2x2BinaryTcpServerLocalPort INTEGER, wtWebio577xxEA2x2BinaryTcpServerInputTrigger OCTET STRING, wtWebio577xxEA2x2BinaryTcpServerApplicationMode OCTET STRING, wtWebio577xxEA2x2BinaryTcpClientLocalPort INTEGER, wtWebio577xxEA2x2BinaryTcpClientServerPort INTEGER, wtWebio577xxEA2x2BinaryTcpClientServerIpAddr OCTET STRING, wtWebio577xxEA2x2BinaryTcpClientServerPassword OCTET STRING, wtWebio577xxEA2x2BinaryTcpClientInactivity INTEGER, wtWebio577xxEA2x2BinaryTcpClientInputTrigger OCTET STRING, wtWebio577xxEA2x2BinaryTcpClientInterval INTEGER, wtWebio577xxEA2x2BinaryTcpClientApplicationMode OCTET STRING, wtWebio577xxEA2x2BinaryUdpPeerLocalPort INTEGER, wtWebio577xxEA2x2BinaryUdpPeerRemotePort INTEGER, wtWebio577xxEA2x2BinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebio577xxEA2x2BinaryUdpPeerInputTrigger OCTET STRING, wtWebio577xxEA2x2BinaryUdpPeerInterval INTEGER, wtWebio577xxEA2x2BinaryUdpPeerApplicationMode OCTET STRING, wtWebio577xxEA2x2BinaryConnectedPort INTEGER, wtWebio577xxEA2x2BinaryConnectedIpAddr IpAddress, wtWebio577xxEA2x2BinaryTcpServerClientHttpPort INTEGER, wtWebio577xxEA2x2BinaryTcpClientServerHttpPort INTEGER, wtWebio577xxEA2x2BinaryTcpClientServerUserName OCTET STRING } wtWebio577xxEA2x2BinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebio577xxEA2x2BinaryEntry 1 } wtWebio577xxEA2x2BinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebio577xxEA2x2BinaryEntry 2 } wtWebio577xxEA2x2BinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebio577xxEA2x2BinaryEntry 3 } wtWebio577xxEA2x2BinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebio577xxEA2x2BinaryEntry 4 } wtWebio577xxEA2x2BinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebio577xxEA2x2BinaryEntry 5 } wtWebio577xxEA2x2BinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebio577xxEA2x2BinaryEntry 6 } wtWebio577xxEA2x2BinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebio577xxEA2x2BinaryEntry 7 } wtWebio577xxEA2x2BinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebio577xxEA2x2BinaryEntry 8 } wtWebio577xxEA2x2BinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebio577xxEA2x2BinaryEntry 9 } wtWebio577xxEA2x2BinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebio577xxEA2x2BinaryEntry 10 } wtWebio577xxEA2x2BinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebio577xxEA2x2BinaryEntry 11 } wtWebio577xxEA2x2BinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebio577xxEA2x2BinaryEntry 12 } wtWebio577xxEA2x2BinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebio577xxEA2x2BinaryEntry 13 } wtWebio577xxEA2x2BinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebio577xxEA2x2BinaryEntry 14 } wtWebio577xxEA2x2BinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebio577xxEA2x2BinaryEntry 15 } wtWebio577xxEA2x2BinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebio577xxEA2x2BinaryEntry 16 } wtWebio577xxEA2x2BinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebio577xxEA2x2BinaryEntry 17 } wtWebio577xxEA2x2BinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebio577xxEA2x2BinaryEntry 18 } wtWebio577xxEA2x2BinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebio577xxEA2x2BinaryEntry 19 } wtWebio577xxEA2x2BinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebio577xxEA2x2BinaryEntry 20 } wtWebio577xxEA2x2BinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebio577xxEA2x2BinaryEntry 21 } wtWebio577xxEA2x2BinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebio577xxEA2x2BinaryEntry 22 } wtWebio577xxEA2x2BinaryTcpClientServerUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "User Name to login at the remote server, if authentication needed." ::= { wtWebio577xxEA2x2BinaryEntry 23 } -- wtWebio577xxEA2x2Syslog Group -------------------------------- wtWebio577xxEA2x2SyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebio577xxEA2x2Syslog 1 } wtWebio577xxEA2x2SyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebio577xxEA2x2Syslog 2 } wtWebio577xxEA2x2SyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebio577xxEA2x2Syslog 3 } wtWebio577xxEA2x2SyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebio577xxEA2x2Syslog 4 } -- wtWebio577xxEA2x2FTP Group -------------------------------- wtWebio577xxEA2x2FTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebio577xxEA2x2FTP 1 } wtWebio577xxEA2x2FTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebio577xxEA2x2FTP 2 } wtWebio577xxEA2x2FTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebio577xxEA2x2FTP 3 } wtWebio577xxEA2x2FTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebio577xxEA2x2FTP 4 } wtWebio577xxEA2x2FTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebio577xxEA2x2FTP 5 } wtWebio577xxEA2x2FTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebio577xxEA2x2FTP 6 } wtWebio577xxEA2x2FTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebio577xxEA2x2FTP 7 } -- wtWebio577xxEA2x2MQTT Group -------------------------------- wtWebio577xxEA2x2MQTTEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 7 schaltet MQTT frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0-6: ungenutzt Bit 7 : MQTT enable" ::= { wtWebio577xxEA2x2MQTT 1 } wtWebio577xxEA2x2MQTTBrockerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP-address of the MQTT-Server." ::= { wtWebio577xxEA2x2MQTT 2 } wtWebio577xxEA2x2MQTTUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT login user name." ::= { wtWebio577xxEA2x2MQTT 3 } wtWebio577xxEA2x2MQTTPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT login password." ::= { wtWebio577xxEA2x2MQTT 4 } wtWebio577xxEA2x2MQTTLocalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Local port number." ::= { wtWebio577xxEA2x2MQTT 5 } wtWebio577xxEA2x2MQTTBrokerServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Server port number." ::= { wtWebio577xxEA2x2MQTT 6 } wtWebio577xxEA2x2MQTTInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Ping intervall, if no data has to be send: time in seconds." ::= { wtWebio577xxEA2x2MQTT 7 } wtWebio577xxEA2x2MQTTLastWillEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activate MQTT LastWill message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will enable" ::= { wtWebio577xxEA2x2MQTT 8 } wtWebio577xxEA2x2MQTTLastWillTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will Topic." ::= { wtWebio577xxEA2x2MQTT 9 } wtWebio577xxEA2x2MQTTLastWillMsg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will message." ::= { wtWebio577xxEA2x2MQTT 10 } wtWebio577xxEA2x2MQTTLastWillQoS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded MQTT Publish QoS: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused" ::= { wtWebio577xxEA2x2MQTT 11 } wtWebio577xxEA2x2MQTTLastWillRetain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded MQTT Publish Retain properties: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused" ::= { wtWebio577xxEA2x2MQTT 12 } wtWebio577xxEA2x2MQTTLastWillConnectEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activate MQTT LastWill Connect message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will connect message enable" ::= { wtWebio577xxEA2x2MQTT 13 } wtWebio577xxEA2x2MQTTLastWillConnectMsg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will Connect message will be send with the QoS and Retain settings of the LastWill message." ::= { wtWebio577xxEA2x2MQTT 14 } -- wtWebio577xxEA1x1REST Group -------------------------------- wtWebio577xxEA2x2RESTEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activates REST: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : REST enable" ::= { wtWebio577xxEA2x2REST 1 } wtWebio577xxEA2x2RESTDigestAuthEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activates Digest-Authentification: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Digest Auth enable" ::= { wtWebio577xxEA2x2REST 2 } -- wtWebio577xxEA2x2OutputMode Group -------------------------------- -- OutputMode Table wtWebio577xxEA2x2OutputModeTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA2x2OutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of output mode configurations dependent on the output indices." ::= { wtWebio577xxEA2x2OutputMode 1 } wtWebio577xxEA2x2OutputModeEntry OBJECT-TYPE SYNTAX WtWebio577xxEA2x2OutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output mode configurations of the individual outputs." INDEX { wtWebio577xxEA2x2OutputNo } ::= { wtWebio577xxEA2x2OutputModeTable 1 } WtWebio577xxEA2x2OutputModeEntry ::= SEQUENCE { wtWebio577xxEA2x2OutputModeBit OCTET STRING } wtWebio577xxEA2x2OutputModeBit OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebio577xxEA2x2OutputModeEntry 1 } wtWebio577xxEA2x2SafetyTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined." ::= { wtWebio577xxEA2x2OutputMode 2 } wtWebio577xxEA2x2PowerSupplyEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Activate the 24V power supply.. . Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Power supply enable" ::= { wtWebio577xxEA2x2OutputMode 4 } -- wtWebio577xxEA2x2Alarm Group ---------------------------- wtWebio577xxEA2x2AlarmCount OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebio577xxEA2x2Alarm 1 } -- Alarm Interface Table wtWebio577xxEA2x2AlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA2x2AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebio577xxEA2x2Alarm 2 } wtWebio577xxEA2x2AlarmIfEntry OBJECT-TYPE SYNTAX WtWebio577xxEA2x2AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebio577xxEA2x2AlarmNo } ::= { wtWebio577xxEA2x2AlarmIfTable 1 } WtWebio577xxEA2x2AlarmIfEntry ::= SEQUENCE { wtWebio577xxEA2x2AlarmNo INTEGER } wtWebio577xxEA2x2AlarmNo OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtWebio577xxEA2x2AlarmIfEntry 1 } -- Alarm Table wtWebio577xxEA2x2AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA2x2AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebio577xxEA2x2Alarm 3 } wtWebio577xxEA2x2AlarmEntry OBJECT-TYPE SYNTAX WtWebio577xxEA2x2AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebio577xxEA2x2AlarmNo } ::= { wtWebio577xxEA2x2AlarmTable 1 } WtWebio577xxEA2x2AlarmEntry ::= SEQUENCE { wtWebio577xxEA2x2AlarmInputTrigger OCTET STRING, wtWebio577xxEA2x2AlarmOutputTrigger OCTET STRING, wtWebio577xxEA2x2AlarmSystemTrigger OCTET STRING, wtWebio577xxEA2x2AlarmMaxCounterValue OCTET STRING, wtWebio577xxEA2x2AlarmInterval OCTET STRING, wtWebio577xxEA2x2AlarmEnable OCTET STRING, wtWebio577xxEA2x2AlarmMailAddr OCTET STRING, wtWebio577xxEA2x2AlarmMailSubject OCTET STRING, wtWebio577xxEA2x2AlarmMailText OCTET STRING, wtWebio577xxEA2x2AlarmSnmpManagerIP OCTET STRING, wtWebio577xxEA2x2AlarmSnmpTrapText OCTET STRING, wtWebio577xxEA2x2AlarmUdpIpAddr OCTET STRING, wtWebio577xxEA2x2AlarmUdpPort INTEGER, wtWebio577xxEA2x2AlarmUdpText OCTET STRING, wtWebio577xxEA2x2AlarmTcpIpAddr OCTET STRING, wtWebio577xxEA2x2AlarmTcpPort INTEGER, wtWebio577xxEA2x2AlarmTcpText OCTET STRING, wtWebio577xxEA2x2AlarmSyslogIpAddr OCTET STRING, wtWebio577xxEA2x2AlarmSyslogPort INTEGER, wtWebio577xxEA2x2AlarmSyslogText OCTET STRING, wtWebio577xxEA2x2AlarmFtpDataPort OCTET STRING, wtWebio577xxEA2x2AlarmFtpFileName OCTET STRING, wtWebio577xxEA2x2AlarmFtpText OCTET STRING, wtWebio577xxEA2x2AlarmFtpOption OCTET STRING, wtWebio577xxEA2x2AlarmTimerCron OCTET STRING, wtWebio577xxEA2x2AlarmMailReleaseSubject OCTET STRING, wtWebio577xxEA2x2AlarmMailReleaseText OCTET STRING, wtWebio577xxEA2x2AlarmSnmpTrapReleaseText OCTET STRING, wtWebio577xxEA2x2AlarmUdpReleaseText OCTET STRING, wtWebio577xxEA2x2AlarmTcpReleaseText OCTET STRING, wtWebio577xxEA2x2AlarmSyslogReleaseText OCTET STRING, wtWebio577xxEA2x2AlarmFtpReleaseText OCTET STRING, wtWebio577xxEA2x2AlarmGlobalEnable OCTET STRING, wtWebio577xxEA2x2AlarmCombinationLogic OCTET STRING, wtWebio577xxEA2x2AlarmTrgMqttTopic OCTET STRING, wtWebio577xxEA2x2AlarmTrgMqttTopicText OCTET STRING, wtWebio577xxEA2x2AlarmHttpReqAuthEnable OCTET STRING, wtWebio577xxEA2x2AlarmHttpReqAuthUser OCTET STRING, wtWebio577xxEA2x2AlarmHttpReqAuthPassword OCTET STRING, wtWebio577xxEA2x2AlarmHttpReqSetUrl OCTET STRING, wtWebio577xxEA2x2AlarmHttpReqClearUrl OCTET STRING, wtWebio577xxEA2x2AlarmHttpReqServerPort INTEGER, wtWebio577xxEA2x2AlarmMqttTopicPath OCTET STRING, wtWebio577xxEA2x2AlarmMqttTopicSetTopic OCTET STRING, wtWebio577xxEA2x2AlarmMqttTopicClear OCTET STRING, wtWebio577xxEA2x2AlarmSetOutputsOwn OCTET STRING, wtWebio577xxEA2x2AlarmSetOutputsServerIp OCTET STRING, wtWebio577xxEA2x2AlarmSetOutputsServerPort INTEGER, wtWebio577xxEA2x2AlarmSetOutputsServerPassword OCTET STRING, wtWebio577xxEA2x2AlarmSetOutputsServerOutputs OCTET STRING, wtWebio577xxEA2x2AlarmSetOutputsDest OCTET STRING, wtWebio577xxEA2x2AlarmSnmpManagerPort INTEGER, wtWebio577xxEA2x2AlarmMqttQoS OCTET STRING, wtWebio577xxEA2x2AlarmMqttRetain OCTET STRING } wtWebio577xxEA2x2AlarmInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital inputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital inputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1" ::= { wtWebio577xxEA2x2AlarmEntry 1 } wtWebio577xxEA2x2AlarmOutputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1" ::= { wtWebio577xxEA2x2AlarmEntry 2 } wtWebio577xxEA2x2AlarmSystemTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control" ::= { wtWebio577xxEA2x2AlarmEntry 3 } wtWebio577xxEA2x2AlarmMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebio577xxEA2x2AlarmInputTrigger are not considered." ::= { wtWebio577xxEA2x2AlarmEntry 4 } wtWebio577xxEA2x2AlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebio577xxEA2x2AlarmEntry 5 } wtWebio577xxEA2x2AlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Bit 0: UDP enable Bit1-7: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable Bit 3: Syslog Messages enable Bit 4: FTP enable Bit 5: HTTP Request enable Bit 6 MQTT Publish enable Bit 7: Set Outputs" ::= { wtWebio577xxEA2x2AlarmEntry 6 } wtWebio577xxEA2x2AlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebio577xxEA2x2AlarmEntry 7 } wtWebio577xxEA2x2AlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebio577xxEA2x2AlarmEntry 8 } wtWebio577xxEA2x2AlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebio577xxEA2x2AlarmEntry 9 } wtWebio577xxEA2x2AlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebio577xxEA2x2AlarmEntry 10 } wtWebio577xxEA2x2AlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebio577xxEA2x2AlarmEntry 11 } wtWebio577xxEA2x2AlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebio577xxEA2x2AlarmEntry 12 } wtWebio577xxEA2x2AlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebio577xxEA2x2AlarmEntry 13 } wtWebio577xxEA2x2AlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebio577xxEA2x2AlarmEntry 14 } wtWebio577xxEA2x2AlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebio577xxEA2x2AlarmEntry 15 } wtWebio577xxEA2x2AlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebio577xxEA2x2AlarmEntry 16 } wtWebio577xxEA2x2AlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebio577xxEA2x2AlarmEntry 17 } wtWebio577xxEA2x2AlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebio577xxEA2x2AlarmEntry 18 } wtWebio577xxEA2x2AlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebio577xxEA2x2AlarmEntry 19 } wtWebio577xxEA2x2AlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebio577xxEA2x2AlarmEntry 20 } wtWebio577xxEA2x2AlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebio577xxEA2x2AlarmEntry 21 } wtWebio577xxEA2x2AlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebio577xxEA2x2AlarmEntry 22 } wtWebio577xxEA2x2AlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebio577xxEA2x2AlarmEntry 23 } wtWebio577xxEA2x2AlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebio577xxEA2x2AlarmEntry 24 } wtWebio577xxEA2x2AlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebio577xxEA2x2AlarmEntry 25 } wtWebio577xxEA2x2AlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebio577xxEA2x2AlarmEntry 26 } wtWebio577xxEA2x2AlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebio577xxEA2x2AlarmEntry 27 } wtWebio577xxEA2x2AlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebio577xxEA2x2AlarmEntry 28 } wtWebio577xxEA2x2AlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebio577xxEA2x2AlarmEntry 29 } wtWebio577xxEA2x2AlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebio577xxEA2x2AlarmEntry 30 } wtWebio577xxEA2x2AlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebio577xxEA2x2AlarmEntry 31 } wtWebio577xxEA2x2AlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebio577xxEA2x2AlarmEntry 32 } wtWebio577xxEA2x2AlarmGlobalEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm activation: Bit 0 = LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Alarm enable" ::= { wtWebio577xxEA2x2AlarmEntry 34 } wtWebio577xxEA2x2AlarmCombinationLogic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded logic: Bit 0 = LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : OR Bit 0 : AND" ::= { wtWebio577xxEA2x2AlarmEntry 58 } wtWebio577xxEA2x2AlarmTrgMqttTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT subscribe topic." ::= { wtWebio577xxEA2x2AlarmEntry 59 } wtWebio577xxEA2x2AlarmTrgMqttTopicText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reveiving this message from the MQTT Broker, this alarm will be triggered." ::= { wtWebio577xxEA2x2AlarmEntry 60 } wtWebio577xxEA2x2AlarmHttpReqAuthEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binnary coded value: Bit 0 = LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable" ::= { wtWebio577xxEA2x2AlarmEntry 61 } wtWebio577xxEA2x2AlarmHttpReqAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: User" ::= { wtWebio577xxEA2x2AlarmEntry 62 } wtWebio577xxEA2x2AlarmHttpReqAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Password" ::= { wtWebio577xxEA2x2AlarmEntry 63 } wtWebio577xxEA2x2AlarmHttpReqSetUrl OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Set URL" ::= { wtWebio577xxEA2x2AlarmEntry 64 } wtWebio577xxEA2x2AlarmHttpReqClearUrl OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Clear URL" ::= { wtWebio577xxEA2x2AlarmEntry 65 } wtWebio577xxEA2x2AlarmHttpReqServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Server Port" ::= { wtWebio577xxEA2x2AlarmEntry 66 } wtWebio577xxEA2x2AlarmMqttTopicPath OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic path" ::= { wtWebio577xxEA2x2AlarmEntry 67 } wtWebio577xxEA2x2AlarmMqttTopicSetTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic SET message" ::= { wtWebio577xxEA2x2AlarmEntry 68 } wtWebio577xxEA2x2AlarmMqttTopicClear OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic CLEAR message" ::= { wtWebio577xxEA2x2AlarmEntry 69 } wtWebio577xxEA2x2AlarmSetOutputsOwn OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1 OCTETS 9-12 are unused." ::= { wtWebio577xxEA2x2AlarmEntry 70 } wtWebio577xxEA2x2AlarmSetOutputsServerIp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Outputs: Server IP Address" ::= { wtWebio577xxEA2x2AlarmEntry 71 } wtWebio577xxEA2x2AlarmSetOutputsServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Set Outputs: Server Port" ::= { wtWebio577xxEA2x2AlarmEntry 72 } wtWebio577xxEA2x2AlarmSetOutputsServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Outputs: Server Pasword" ::= { wtWebio577xxEA2x2AlarmEntry 73 } wtWebio577xxEA2x2AlarmSetOutputsServerOutputs OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1 OCTETS 9-12 are unused." ::= { wtWebio577xxEA2x2AlarmEntry 74 } wtWebio577xxEA2x2AlarmSetOutputsDest OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Bit 0 = LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : set outputs of remote server. Bit 0 : set outputs of this WEB-IO" ::= { wtWebio577xxEA2x2AlarmEntry 75 } wtWebio577xxEA2x2AlarmSnmpManagerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebio577xxEA2x2AlarmEntry 76 } wtWebio577xxEA2x2AlarmMqttQoS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused" ::= { wtWebio577xxEA2x2AlarmEntry 77 } wtWebio577xxEA2x2AlarmMqttRetain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused" ::= { wtWebio577xxEA2x2AlarmEntry 78 } -- wtWebio577xxEA2x2LoadControl ---------------------------- wtWebio577xxEA2x2LoadControlView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Here the result of automatic load control can be read. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1." ::= { wtWebio577xxEA2x2Alarm 4 } wtWebio577xxEA2x2LCShutDownView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Here the result of the automatic load control shut down can be read. All outputs remain switched of, until a zero is written into this variable. But previously all loads should be inspected. High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason. If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair. All controlled output could be identified reading the variable wtWebio577xxEA2x2LoadControlEnable. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1." ::= { wtWebio577xxEA2x2Alarm 5 } -- wtWebio577xxEA2x2Ports Group ---------------------------- -- Input Port Table wtWebio577xxEA2x2InputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA2x2InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebio577xxEA2x2Ports 1 } wtWebio577xxEA2x2InputPortEntry OBJECT-TYPE SYNTAX WtWebio577xxEA2x2InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebio577xxEA2x2InputNo } ::= { wtWebio577xxEA2x2InputPortTable 1 } WtWebio577xxEA2x2InputPortEntry ::= SEQUENCE { wtWebio577xxEA2x2PortInputName OCTET STRING, wtWebio577xxEA2x2PortInputText OCTET STRING, wtWebio577xxEA2x2PortInputMode OCTET STRING, wtWebio577xxEA2x2PortInputFilter INTEGER, wtWebio577xxEA2x2PortInputBicountPulsePolarity OCTET STRING, wtWebio577xxEA2x2PortInputBicountInactivTimeout INTEGER } wtWebio577xxEA2x2PortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebio577xxEA2x2InputPortEntry 1 } wtWebio577xxEA2x2PortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebio577xxEA2x2InputPortEntry 2 } wtWebio577xxEA2x2PortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. Selection for input 0-1: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Bidirectional counter enable Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable" ::= { wtWebio577xxEA2x2InputPortEntry 3 } wtWebio577xxEA2x2PortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebio577xxEA2x2InputPortEntry 4 } wtWebio577xxEA2x2PortInputBicountPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebio577xxEA2x2InputPortEntry 5 } wtWebio577xxEA2x2PortInputBicountInactivTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored." ::= { wtWebio577xxEA2x2InputPortEntry 6 } -- Output Port Table wtWebio577xxEA2x2OutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA2x2OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtWebio577xxEA2x2Ports 2 } wtWebio577xxEA2x2OutputPortEntry OBJECT-TYPE SYNTAX WtWebio577xxEA2x2OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtWebio577xxEA2x2OutputNo } ::= { wtWebio577xxEA2x2OutputPortTable 1 } WtWebio577xxEA2x2OutputPortEntry ::= SEQUENCE { wtWebio577xxEA2x2PortOutputName OCTET STRING, wtWebio577xxEA2x2PortOutputText OCTET STRING, wtWebio577xxEA2x2PortOutputGroupMode OCTET STRING, wtWebio577xxEA2x2PortOutputSafetyState OCTET STRING, wtWebio577xxEA2x2PortLogicInputMask OCTET STRING, wtWebio577xxEA2x2PortLogicInputInverter OCTET STRING, wtWebio577xxEA2x2PortLogicFunction OCTET STRING, wtWebio577xxEA2x2PortLogicOutputInverter OCTET STRING, wtWebio577xxEA2x2PortPulseDuration INTEGER, wtWebio577xxEA2x2PortPulsePolarity OCTET STRING } wtWebio577xxEA2x2PortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtWebio577xxEA2x2OutputPortEntry 1 } wtWebio577xxEA2x2PortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtWebio577xxEA2x2OutputPortEntry 2 } wtWebio577xxEA2x2PortOutputGroupMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one ouput bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for ouputs 0-1: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : ouputs 0,1 disconnected (default) Bit 1 : ouputs 0+1 connected" ::= { wtWebio577xxEA2x2OutputPortEntry 3 } wtWebio577xxEA2x2PortOutputSafetyState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output" ::= { wtWebio577xxEA2x2OutputPortEntry 4 } wtWebio577xxEA2x2PortLogicInputMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebio577xxEA2x2PortLogicInputMask) 2. Inverting inputs if necessary (wtWebio577xxEA2x2PortLogicInputInverter) 3. Logical combination (wtWebio577xxEA2x2PortLogicFunction) 4. Inverting the result if necessary (wtWebio577xxEA2x2PortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1" ::= { wtWebio577xxEA2x2OutputPortEntry 5 } wtWebio577xxEA2x2PortLogicInputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1" ::= { wtWebio577xxEA2x2OutputPortEntry 6 } wtWebio577xxEA2x2PortLogicFunction OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused" ::= { wtWebio577xxEA2x2OutputPortEntry 7 } wtWebio577xxEA2x2PortLogicOutputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused" ::= { wtWebio577xxEA2x2OutputPortEntry 8 } wtWebio577xxEA2x2PortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtWebio577xxEA2x2OutputPortEntry 9 } wtWebio577xxEA2x2PortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtWebio577xxEA2x2PortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebio577xxEA2x2OutputPortEntry 10 } -- wtWebio577xxEA2x2Manufact Group ---------------------------- wtWebio577xxEA2x2MfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebio577xxEA2x2Manufact 1 } wtWebio577xxEA2x2MfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebio577xxEA2x2Manufact 2 } wtWebio577xxEA2x2MfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebio577xxEA2x2Manufact 3 } wtWebio577xxEA2x2MfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebio577xxEA2x2Manufact 4 } wtWebio577xxEA2x2MfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebio577xxEA2x2Manufact 5 } -- wtWebio577xxEA2x2Diag Group ---------------------------- wtWebio577xxEA2x2DiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebio577xxEA2x2Diag 1 } wtWebio577xxEA2x2DiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebio577xxEA2x2Diag 2 } wtWebio577xxEA2x2DiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebio577xxEA2x2DiagErrorMessage. Errors are numbered from 1 to wtWebio577xxEA2x2DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebio577xxEA2x2DiagErrorMessage." ::= { wtWebio577xxEA2x2Diag 3 } wtWebio577xxEA2x2DiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebio577xxEA2x2DiagErrorIndex as an index, the appropriate message is available." ::= { wtWebio577xxEA2x2Diag 4 } wtWebio577xxEA2x2DiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebio577xxEA2x2Diag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebio577xxEA2x2Alert1 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtWebio577xxEA2x2Alert2 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtWebio577xxEA2x2Alert3 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtWebio577xxEA2x2Alert4 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtWebio577xxEA2x2Alert5 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtWebio577xxEA2x2Alert6 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtWebio577xxEA2x2Alert7 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtWebio577xxEA2x2Alert8 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtWebio577xxEA2x2Alert9 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtWebio577xxEA2x2Alert10 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtWebio577xxEA2x2Alert11 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtWebio577xxEA2x2Alert12 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtWebio577xxEA2x2Alert13 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebio577xxEA2x2Alert14 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebio577xxEA2x2Alert15 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebio577xxEA2x2Alert16 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebio577xxEA2x2Alert17 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebio577xxEA2x2Alert18 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebio577xxEA2x2Alert19 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebio577xxEA2x2Alert20 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebio577xxEA2x2Alert21 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtWebio577xxEA2x2Alert22 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtWebio577xxEA2x2Alert23 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebio577xxEA2x2Alert24 TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebio577xxEA2x2AlertDiag TRAP-TYPE ENTERPRISE wtWebio577xxEA2x2 VARIABLES { wtWebio577xxEA2x2DiagErrorIndex, wtWebio577xxEA2x2DiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebioEA2x2InOut Group ------------------------ wtWebioEA2x2Inputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtWebioEA2x2InOut 1 } wtWebioEA2x2Outputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent outputs." ::= { wtWebioEA2x2InOut 2 } -- Input Interface Table wtWebioEA2x2InputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebioEA2x2InOut 3 } wtWebioEA2x2InputEntry OBJECT-TYPE SYNTAX WtWebioEA2x2InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtWebioEA2x2InputNo } ::= { wtWebioEA2x2InputTable 1 } WtWebioEA2x2InputEntry ::= SEQUENCE { wtWebioEA2x2InputNo INTEGER, wtWebioEA2x2InputCounter INTEGER, wtWebioEA2x2InputCounterClear INTEGER, wtWebioEA2x2InputState INTEGER } wtWebioEA2x2InputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebioEA2x2InputEntry 1 } wtWebioEA2x2InputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebioEA2x2InputEntry 2 } wtWebioEA2x2InputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtWebioEA2x2InputEntry 3 } wtWebioEA2x2InputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of a single input bit, 0-OFF, 1-ON." ::= { wtWebioEA2x2InputEntry 4 } wtWebioEA2x2InputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1" ::= { wtWebioEA2x2InOut 4 } -- Output Interface Table wtWebioEA2x2OutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtWebioEA2x2InOut 5 } wtWebioEA2x2OutputEntry OBJECT-TYPE SYNTAX WtWebioEA2x2OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtWebioEA2x2OutputNo } ::= { wtWebioEA2x2OutputTable 1 } WtWebioEA2x2OutputEntry ::= SEQUENCE { wtWebioEA2x2OutputNo INTEGER, wtWebioEA2x2OutputState INTEGER } wtWebioEA2x2OutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtWebioEA2x2OutputEntry 1 } wtWebioEA2x2OutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of a single output bit, 0-OFF, 1-ON." ::= { wtWebioEA2x2OutputEntry 2 } wtWebioEA2x2OutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt" ::= { wtWebioEA2x2InOut 6 } wtWebioEA2x2SetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1" ::= { wtWebioEA2x2InOut 7 } -- wtWebioEA2x2SessCntrl Group -------------------------------- wtWebioEA2x2SessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebioEA2x2SessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebioEA2x2SessCntrl 1 } wtWebioEA2x2SessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebioEA2x2SessCntrl 2 } wtWebioEA2x2SessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebioEA2x2SessCntrl 3 } wtWebioEA2x2SessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebioEA2x2SessCntrl 4 } wtWebioEA2x2SessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebioEA2x2SessCntrl 5 } -- wtWebioEA2x2Text Group ------------------------ wtWebioEA2x2DeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebioEA2x2Text 1 } wtWebioEA2x2DeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebioEA2x2Text 2 } wtWebioEA2x2DeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebioEA2x2Text 3 } wtWebioEA2x2DeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebioEA2x2Text 4 } -- wtWebioEA2x2TimeZone Group ---------------------------- wtWebioEA2x2TzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebioEA2x2TimeZone 1 } wtWebioEA2x2TzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebioEA2x2TimeZone 2 } wtWebioEA2x2TzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebioEA2x2TimeZone 3 } wtWebioEA2x2StTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebioEA2x2TimeZone 4 } wtWebioEA2x2StTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebioEA2x2TimeZone 5 } wtWebioEA2x2StTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebioEA2x2TimeZone 6 } wtWebioEA2x2StTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2StartMonth-January(1), wtWebioEA2x2StartMonth-February(2), wtWebioEA2x2StartMonth-March(3), wtWebioEA2x2StartMonth-April(4), wtWebioEA2x2StartMonth-May(5), wtWebioEA2x2StartMonth-June(6), wtWebioEA2x2StartMonth-July(7), wtWebioEA2x2StartMonth-August(8), wtWebioEA2x2StartMonth-September(9), wtWebioEA2x2StartMonth-October(10), wtWebioEA2x2StartMonth-November(11), wtWebioEA2x2StartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebioEA2x2TimeZone 7 } wtWebioEA2x2StTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2StartMode-first(1), wtWebioEA2x2StartMode-second(2), wtWebioEA2x2StartMode-third(3), wtWebioEA2x2StartMode-fourth(4), wtWebioEA2x2StartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebioEA2x2TimeZone 8 } wtWebioEA2x2StTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2StartWday-Sunday(1), wtWebioEA2x2StartWday-Monday(2), wtWebioEA2x2StartWday-Tuesday(3), wtWebioEA2x2StartWday-Thursday(4), wtWebioEA2x2StartWday-Wednesday(5), wtWebioEA2x2StartWday-Friday(6), wtWebioEA2x2StartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebioEA2x2TimeZone 9 } wtWebioEA2x2StTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA2x2TimeZone 10 } wtWebioEA2x2StTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA2x2TimeZone 11 } wtWebioEA2x2StTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2StopMonth-January(1), wtWebioEA2x2StopMonth-February(2), wtWebioEA2x2StopMonth-March(3), wtWebioEA2x2StopMonth-April(4), wtWebioEA2x2StopMonth-May(5), wtWebioEA2x2StopMonth-June(6), wtWebioEA2x2StopMonth-July(7), wtWebioEA2x2StopMonth-August(8), wtWebioEA2x2StopMonth-September(9), wtWebioEA2x2StopMonth-October(10), wtWebioEA2x2StopMonth-November(11), wtWebioEA2x2StopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebioEA2x2TimeZone 12 } wtWebioEA2x2StTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2StopMode-first(1), wtWebioEA2x2StopMode-second(2), wtWebioEA2x2StopMode-third(3), wtWebioEA2x2StopMode-fourth(4), wtWebioEA2x2StopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebioEA2x2TimeZone 13 } wtWebioEA2x2StTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2StopWday-Sunday(1), wtWebioEA2x2StopWday-Monday(2), wtWebioEA2x2StopWday-Tuesday(3), wtWebioEA2x2StopWday-Thursday(4), wtWebioEA2x2StopWday-Wednesday(5), wtWebioEA2x2StopWday-Friday(6), wtWebioEA2x2StopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebioEA2x2TimeZone 14 } wtWebioEA2x2StTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA2x2TimeZone 15 } wtWebioEA2x2StTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA2x2TimeZone 16 } -- wtWebioEA2x2TimeServer Group ---------------------------- wtWebioEA2x2TimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebioEA2x2TimeServer 1 } wtWebioEA2x2TimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebioEA2x2TimeServer 2 } wtWebioEA2x2TsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebioEA2x2TimeServer 3 } wtWebioEA2x2TsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebioEA2x2TimeServer 4 } -- wtWebioEA2x2DeviceClock Group ---------------------------- wtWebioEA2x2ClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebioEA2x2DeviceClock 1 } wtWebioEA2x2ClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebioEA2x2DeviceClock 2 } wtWebioEA2x2ClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebioEA2x2DeviceClock 3 } wtWebioEA2x2ClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ClockMonth-January(1), wtWebioEA2x2ClockMonth-February(2), wtWebioEA2x2ClockMonth-March(3), wtWebioEA2x2ClockMonth-April(4), wtWebioEA2x2ClockMonth-May(5), wtWebioEA2x2ClockMonth-June(6), wtWebioEA2x2ClockMonth-July(7), wtWebioEA2x2ClockMonth-August(8), wtWebioEA2x2ClockMonth-September(9), wtWebioEA2x2ClockMonth-October(10), wtWebioEA2x2ClockMonth-November(11), wtWebioEA2x2ClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebioEA2x2DeviceClock 4 } wtWebioEA2x2ClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebioEA2x2DeviceClock 5 } -- wtWebioEA2x2Network Group ------------------------ wtWebioEA2x2IpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebioEA2x2Network 1 } wtWebioEA2x2SubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebioEA2x2Network 2 } wtWebioEA2x2Gateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebioEA2x2Network 3 } wtWebioEA2x2DnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebioEA2x2Network 4 } wtWebioEA2x2DnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebioEA2x2Network 5 } wtWebioEA2x2AddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebioEA2x2Network 6 } -- wtWebioEA2x2HTTP Group -------------------------------- wtWebioEA2x2Startup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebioEA2x2HTTP 1 } wtWebioEA2x2GetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebioEA2x2HTTP 2 } wtWebioEA2x2HttpInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2HTTP 3 } wtWebioEA2x2HttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebioEA2x2HTTP 4 } -- wtWebioEA2x2Mail Group -------------------------------- wtWebioEA2x2MailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebioEA2x2Mail 1 } wtWebioEA2x2MailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebioEA2x2Mail 2 } wtWebioEA2x2MailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebioEA2x2Mail 3 } wtWebioEA2x2MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebioEA2x2Mail 4 } wtWebioEA2x2MailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebioEA2x2Mail 5 } wtWebioEA2x2MailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebioEA2x2Mail 6 } wtWebioEA2x2MailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebioEA2x2Mail 7 } wtWebioEA2x2MailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebioEA2x2Mail 8 } -- wtWebioEA2x2Snmp Group -------------------------------- wtWebioEA2x2SnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebioEA2x2SNMP 1 } wtWebioEA2x2SnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebioEA2x2SNMP 2 } wtWebioEA2x2SnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebioEA2x2SNMP 3 } wtWebioEA2x2SnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebioEA2x2SNMP 4 } wtWebioEA2x2SnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtWebioEA2x2SNMP 5 } -- wtWebioEA2x2UDP Group -------------------------------- wtWebioEA2x2UdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebioEA2x2UDP 1 } wtWebioEA2x2UdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebioEA2x2UDP 2 } wtWebioEA2x2UdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebioEA2x2UDP 3 } -- wtWebioEA2x2Binary Group -------------------------------- wtWebioEA2x2BinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebioEA2x2Binary 1 } -- Binary Interface Table wtWebioEA2x2BinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebioEA2x2Binary 2 } wtWebioEA2x2BinaryIfEntry OBJECT-TYPE SYNTAX WtWebioEA2x2BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebioEA2x2BinaryModeNo } ::= { wtWebioEA2x2BinaryIfTable 1 } WtWebioEA2x2BinaryIfEntry ::= SEQUENCE { wtWebioEA2x2BinaryModeNo INTEGER } wtWebioEA2x2BinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebioEA2x2BinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebioEA2x2BinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebioEA2x2Binary 3 } wtWebioEA2x2BinaryEntry OBJECT-TYPE SYNTAX WtWebioEA2x2BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebioEA2x2BinaryModeNo } ::= { wtWebioEA2x2BinaryTable 1 } WtWebioEA2x2BinaryEntry ::= SEQUENCE { wtWebioEA2x2BinaryOperationMode OCTET STRING, wtWebioEA2x2BinaryTcpServerLocalPort INTEGER, wtWebioEA2x2BinaryTcpServerInputTrigger OCTET STRING, wtWebioEA2x2BinaryTcpServerApplicationMode OCTET STRING, wtWebioEA2x2BinaryTcpClientLocalPort INTEGER, wtWebioEA2x2BinaryTcpClientServerPort INTEGER, wtWebioEA2x2BinaryTcpClientServerIpAddr OCTET STRING, wtWebioEA2x2BinaryTcpClientServerPassword OCTET STRING, wtWebioEA2x2BinaryTcpClientInactivity INTEGER, wtWebioEA2x2BinaryTcpClientInputTrigger OCTET STRING, wtWebioEA2x2BinaryTcpClientInterval INTEGER, wtWebioEA2x2BinaryTcpClientApplicationMode OCTET STRING, wtWebioEA2x2BinaryUdpPeerLocalPort INTEGER, wtWebioEA2x2BinaryUdpPeerRemotePort INTEGER, wtWebioEA2x2BinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebioEA2x2BinaryUdpPeerInputTrigger OCTET STRING, wtWebioEA2x2BinaryUdpPeerInterval INTEGER, wtWebioEA2x2BinaryUdpPeerApplicationMode OCTET STRING, wtWebioEA2x2BinaryConnectedPort INTEGER, wtWebioEA2x2BinaryConnectedIpAddr IpAddress, wtWebioEA2x2BinaryTcpServerClientHttpPort INTEGER, wtWebioEA2x2BinaryTcpClientServerHttpPort INTEGER } wtWebioEA2x2BinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebioEA2x2BinaryEntry 1 } wtWebioEA2x2BinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA2x2BinaryEntry 2 } wtWebioEA2x2BinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2BinaryEntry 3 } wtWebioEA2x2BinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA2x2BinaryEntry 4 } wtWebioEA2x2BinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA2x2BinaryEntry 5 } wtWebioEA2x2BinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebioEA2x2BinaryEntry 6 } wtWebioEA2x2BinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebioEA2x2BinaryEntry 7 } wtWebioEA2x2BinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebioEA2x2BinaryEntry 8 } wtWebioEA2x2BinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebioEA2x2BinaryEntry 9 } wtWebioEA2x2BinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2BinaryEntry 10 } wtWebioEA2x2BinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebioEA2x2BinaryEntry 11 } wtWebioEA2x2BinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA2x2BinaryEntry 12 } wtWebioEA2x2BinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA2x2BinaryEntry 13 } wtWebioEA2x2BinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebioEA2x2BinaryEntry 14 } wtWebioEA2x2BinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebioEA2x2BinaryEntry 15 } wtWebioEA2x2BinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2BinaryEntry 16 } wtWebioEA2x2BinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebioEA2x2BinaryEntry 17 } wtWebioEA2x2BinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA2x2BinaryEntry 18 } wtWebioEA2x2BinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebioEA2x2BinaryEntry 19 } wtWebioEA2x2BinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebioEA2x2BinaryEntry 20 } wtWebioEA2x2BinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebioEA2x2BinaryEntry 21 } wtWebioEA2x2BinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebioEA2x2BinaryEntry 22 } -- wtWebioEA2x2Syslog Group -------------------------------- wtWebioEA2x2SyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebioEA2x2Syslog 1 } wtWebioEA2x2SyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebioEA2x2Syslog 2 } wtWebioEA2x2SyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebioEA2x2Syslog 3 } wtWebioEA2x2SyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebioEA2x2Syslog 4 } -- wtWebioEA2x2FTP Group -------------------------------- wtWebioEA2x2FTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebioEA2x2FTP 1 } wtWebioEA2x2FTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioEA2x2FTP 2 } wtWebioEA2x2FTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebioEA2x2FTP 3 } wtWebioEA2x2FTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebioEA2x2FTP 4 } wtWebioEA2x2FTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebioEA2x2FTP 5 } wtWebioEA2x2FTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebioEA2x2FTP 6 } wtWebioEA2x2FTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebioEA2x2FTP 7 } -- wtWebioEA2x2OutputMode Group -------------------------------- -- OutputMode Table wtWebioEA2x2OutputModeTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2OutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of output mode configurations dependent on the output indices." ::= { wtWebioEA2x2OutputMode 1 } wtWebioEA2x2OutputModeEntry OBJECT-TYPE SYNTAX WtWebioEA2x2OutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output mode configurations of the individual outputs." INDEX { wtWebioEA2x2OutputNo } ::= { wtWebioEA2x2OutputModeTable 1 } WtWebioEA2x2OutputModeEntry ::= SEQUENCE { wtWebioEA2x2OutputModeBit OCTET STRING } wtWebioEA2x2OutputModeBit OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebioEA2x2OutputModeEntry 1 } wtWebioEA2x2SafetyTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined." ::= { wtWebioEA2x2OutputMode 2 } wtWebioEA2x2LoadControlEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Here the function of automatic load control can be enabled. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Load Control enable" ::= { wtWebioEA2x2OutputMode 3 } -- wtWebioEA2x2Alarm Group ---------------------------- wtWebioEA2x2AlarmCount OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebioEA2x2Alarm 1 } -- Alarm Interface Table wtWebioEA2x2AlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebioEA2x2Alarm 2 } wtWebioEA2x2AlarmIfEntry OBJECT-TYPE SYNTAX WtWebioEA2x2AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebioEA2x2AlarmNo } ::= { wtWebioEA2x2AlarmIfTable 1 } WtWebioEA2x2AlarmIfEntry ::= SEQUENCE { wtWebioEA2x2AlarmNo INTEGER } wtWebioEA2x2AlarmNo OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtWebioEA2x2AlarmIfEntry 1 } -- Alarm Table wtWebioEA2x2AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebioEA2x2Alarm 3 } wtWebioEA2x2AlarmEntry OBJECT-TYPE SYNTAX WtWebioEA2x2AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebioEA2x2AlarmNo } ::= { wtWebioEA2x2AlarmTable 1 } WtWebioEA2x2AlarmEntry ::= SEQUENCE { wtWebioEA2x2AlarmInputTrigger OCTET STRING, wtWebioEA2x2AlarmOutputTrigger OCTET STRING, wtWebioEA2x2AlarmSystemTrigger OCTET STRING, wtWebioEA2x2AlarmMaxCounterValue OCTET STRING, wtWebioEA2x2AlarmInterval OCTET STRING, wtWebioEA2x2AlarmEnable OCTET STRING, wtWebioEA2x2AlarmMailAddr OCTET STRING, wtWebioEA2x2AlarmMailSubject OCTET STRING, wtWebioEA2x2AlarmMailText OCTET STRING, wtWebioEA2x2AlarmSnmpManagerIP OCTET STRING, wtWebioEA2x2AlarmSnmpTrapText OCTET STRING, wtWebioEA2x2AlarmUdpIpAddr OCTET STRING, wtWebioEA2x2AlarmUdpPort INTEGER, wtWebioEA2x2AlarmUdpText OCTET STRING, wtWebioEA2x2AlarmTcpIpAddr OCTET STRING, wtWebioEA2x2AlarmTcpPort INTEGER, wtWebioEA2x2AlarmTcpText OCTET STRING, wtWebioEA2x2AlarmSyslogIpAddr OCTET STRING, wtWebioEA2x2AlarmSyslogPort INTEGER, wtWebioEA2x2AlarmSyslogText OCTET STRING, wtWebioEA2x2AlarmFtpDataPort OCTET STRING, wtWebioEA2x2AlarmFtpFileName OCTET STRING, wtWebioEA2x2AlarmFtpText OCTET STRING, wtWebioEA2x2AlarmFtpOption OCTET STRING, wtWebioEA2x2AlarmTimerCron OCTET STRING, wtWebioEA2x2AlarmMailReleaseSubject OCTET STRING, wtWebioEA2x2AlarmMailReleaseText OCTET STRING, wtWebioEA2x2AlarmSnmpTrapReleaseText OCTET STRING, wtWebioEA2x2AlarmUdpReleaseText OCTET STRING, wtWebioEA2x2AlarmTcpReleaseText OCTET STRING, wtWebioEA2x2AlarmSyslogReleaseText OCTET STRING, wtWebioEA2x2AlarmFtpReleaseText OCTET STRING } wtWebioEA2x2AlarmInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital inputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital inputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1" ::= { wtWebioEA2x2AlarmEntry 1 } wtWebioEA2x2AlarmOutputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1" ::= { wtWebioEA2x2AlarmEntry 2 } wtWebioEA2x2AlarmSystemTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control" ::= { wtWebioEA2x2AlarmEntry 3 } wtWebioEA2x2AlarmMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA2x2AlarmInputTrigger are not considered." ::= { wtWebioEA2x2AlarmEntry 4 } wtWebioEA2x2AlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebioEA2x2AlarmEntry 5 } wtWebioEA2x2AlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused" ::= { wtWebioEA2x2AlarmEntry 6 } wtWebioEA2x2AlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebioEA2x2AlarmEntry 7 } wtWebioEA2x2AlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA2x2AlarmEntry 8 } wtWebioEA2x2AlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA2x2AlarmEntry 9 } wtWebioEA2x2AlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebioEA2x2AlarmEntry 10 } wtWebioEA2x2AlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA2x2AlarmEntry 11 } wtWebioEA2x2AlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA2x2AlarmEntry 12 } wtWebioEA2x2AlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA2x2AlarmEntry 13 } wtWebioEA2x2AlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA2x2AlarmEntry 14 } wtWebioEA2x2AlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA2x2AlarmEntry 15 } wtWebioEA2x2AlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA2x2AlarmEntry 16 } wtWebioEA2x2AlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA2x2AlarmEntry 17 } wtWebioEA2x2AlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA2x2AlarmEntry 18 } wtWebioEA2x2AlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA2x2AlarmEntry 19 } wtWebioEA2x2AlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA2x2AlarmEntry 20 } wtWebioEA2x2AlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebioEA2x2AlarmEntry 21 } wtWebioEA2x2AlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebioEA2x2AlarmEntry 22 } wtWebioEA2x2AlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA2x2AlarmEntry 23 } wtWebioEA2x2AlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebioEA2x2AlarmEntry 24 } wtWebioEA2x2AlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebioEA2x2AlarmEntry 25 } wtWebioEA2x2AlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA2x2AlarmEntry 26 } wtWebioEA2x2AlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA2x2AlarmEntry 27 } wtWebioEA2x2AlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA2x2AlarmEntry 28 } wtWebioEA2x2AlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA2x2AlarmEntry 29 } wtWebioEA2x2AlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA2x2AlarmEntry 30 } wtWebioEA2x2AlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA2x2AlarmEntry 31 } wtWebioEA2x2AlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA2x2AlarmEntry 32 } -- wtWebioEA2x2LoadControl ---------------------------- wtWebioEA2x2LoadControlView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Here the result of automatic load control can be read. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1." ::= { wtWebioEA2x2Alarm 4 } wtWebioEA2x2LCShutDownView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Here the result of the automatic load control shut down can be read. All outputs remain switched of, until a zero is written into this variable. But previously all loads should be inspected. High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason. If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair. All controlled output could be identified reading the variable wtWebioEA2x2LoadControlEnable. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1." ::= { wtWebioEA2x2Alarm 5 } -- wtWebioEA2x2Ports Group ---------------------------- -- Input Port Table wtWebioEA2x2InputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebioEA2x2Ports 1 } wtWebioEA2x2InputPortEntry OBJECT-TYPE SYNTAX WtWebioEA2x2InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebioEA2x2InputNo } ::= { wtWebioEA2x2InputPortTable 1 } WtWebioEA2x2InputPortEntry ::= SEQUENCE { wtWebioEA2x2PortInputName OCTET STRING, wtWebioEA2x2PortInputText OCTET STRING, wtWebioEA2x2PortInputMode OCTET STRING, wtWebioEA2x2PortInputFilter INTEGER, wtWebioEA2x2PortInputBicountPulsePolarity OCTET STRING, wtWebioEA2x2PortInputBicountInactivTimeout INTEGER } wtWebioEA2x2PortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebioEA2x2InputPortEntry 1 } wtWebioEA2x2PortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebioEA2x2InputPortEntry 2 } wtWebioEA2x2PortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. Selection for input 0-1: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Bidirectional counter enable Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable" ::= { wtWebioEA2x2InputPortEntry 3 } wtWebioEA2x2PortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebioEA2x2InputPortEntry 4 } wtWebioEA2x2PortInputBicountPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA2x2InputPortEntry 5 } wtWebioEA2x2PortInputBicountInactivTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored." ::= { wtWebioEA2x2InputPortEntry 6 } -- Output Port Table wtWebioEA2x2OutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtWebioEA2x2Ports 2 } wtWebioEA2x2OutputPortEntry OBJECT-TYPE SYNTAX WtWebioEA2x2OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtWebioEA2x2OutputNo } ::= { wtWebioEA2x2OutputPortTable 1 } WtWebioEA2x2OutputPortEntry ::= SEQUENCE { wtWebioEA2x2PortOutputName OCTET STRING, wtWebioEA2x2PortOutputText OCTET STRING, wtWebioEA2x2PortOutputGroupMode OCTET STRING, wtWebioEA2x2PortOutputSafetyState OCTET STRING, wtWebioEA2x2PortLogicInputMask OCTET STRING, wtWebioEA2x2PortLogicInputInverter OCTET STRING, wtWebioEA2x2PortLogicFunction OCTET STRING, wtWebioEA2x2PortLogicOutputInverter OCTET STRING, wtWebioEA2x2PortPulseDuration INTEGER, wtWebioEA2x2PortPulsePolarity OCTET STRING } wtWebioEA2x2PortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtWebioEA2x2OutputPortEntry 1 } wtWebioEA2x2PortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtWebioEA2x2OutputPortEntry 2 } wtWebioEA2x2PortOutputGroupMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one ouput bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for ouputs 0-1: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : ouputs 0,1 disconnected (default) Bit 1 : ouputs 0+1 connected" ::= { wtWebioEA2x2OutputPortEntry 3 } wtWebioEA2x2PortOutputSafetyState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output" ::= { wtWebioEA2x2OutputPortEntry 4 } wtWebioEA2x2PortLogicInputMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA2x2PortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA2x2PortLogicInputInverter) 3. Logical combination (wtWebioEA2x2PortLogicFunction) 4. Inverting the result if necessary (wtWebioEA2x2PortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1" ::= { wtWebioEA2x2OutputPortEntry 5 } wtWebioEA2x2PortLogicInputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1" ::= { wtWebioEA2x2OutputPortEntry 6 } wtWebioEA2x2PortLogicFunction OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused" ::= { wtWebioEA2x2OutputPortEntry 7 } wtWebioEA2x2PortLogicOutputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused" ::= { wtWebioEA2x2OutputPortEntry 8 } wtWebioEA2x2PortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtWebioEA2x2OutputPortEntry 9 } wtWebioEA2x2PortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtWebioEA2x2PortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA2x2OutputPortEntry 10 } -- wtWebioEA2x2Manufact Group ---------------------------- wtWebioEA2x2MfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebioEA2x2Manufact 1 } wtWebioEA2x2MfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebioEA2x2Manufact 2 } wtWebioEA2x2MfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebioEA2x2Manufact 3 } wtWebioEA2x2MfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebioEA2x2Manufact 4 } wtWebioEA2x2MfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebioEA2x2Manufact 5 } -- wtWebioEA2x2Diag Group ---------------------------- wtWebioEA2x2DiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebioEA2x2Diag 1 } wtWebioEA2x2DiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebioEA2x2Diag 2 } wtWebioEA2x2DiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebioEA2x2DiagErrorMessage. Errors are numbered from 1 to wtWebioEA2x2DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA2x2DiagErrorMessage." ::= { wtWebioEA2x2Diag 3 } wtWebioEA2x2DiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebioEA2x2DiagErrorIndex as an index, the appropriate message is available." ::= { wtWebioEA2x2Diag 4 } wtWebioEA2x2DiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebioEA2x2Diag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebioEA2x2Alert1 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtWebioEA2x2Alert2 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtWebioEA2x2Alert3 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtWebioEA2x2Alert4 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtWebioEA2x2Alert5 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtWebioEA2x2Alert6 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtWebioEA2x2Alert7 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtWebioEA2x2Alert8 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtWebioEA2x2Alert9 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtWebioEA2x2Alert10 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtWebioEA2x2Alert11 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtWebioEA2x2Alert12 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtWebioEA2x2Alert13 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebioEA2x2Alert14 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebioEA2x2Alert15 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebioEA2x2Alert16 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebioEA2x2Alert17 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebioEA2x2Alert18 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebioEA2x2Alert19 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebioEA2x2Alert20 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebioEA2x2Alert21 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtWebioEA2x2Alert22 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtWebioEA2x2Alert23 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebioEA2x2Alert24 TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebioEA2x2AlertDiag TRAP-TYPE ENTERPRISE wtWebioEA2x2 VARIABLES { wtWebioEA2x2DiagErrorIndex, wtWebioEA2x2DiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebio577xxEA12x12InOut Group ------------------------ wtWebio577xxEA12x12Inputs OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtWebio577xxEA12x12InOut 1 } wtWebio577xxEA12x12Outputs OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent outputs." ::= { wtWebio577xxEA12x12InOut 2 } -- Input Interface Table wtWebio577xxEA12x12InputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x12InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebio577xxEA12x12InOut 3 } wtWebio577xxEA12x12InputEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x12InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtWebio577xxEA12x12InputNo } ::= { wtWebio577xxEA12x12InputTable 1 } WtWebio577xxEA12x12InputEntry ::= SEQUENCE { wtWebio577xxEA12x12InputNo INTEGER, wtWebio577xxEA12x12InputCounter INTEGER, wtWebio577xxEA12x12InputCounterClear INTEGER, wtWebio577xxEA12x12InputState INTEGER } wtWebio577xxEA12x12InputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebio577xxEA12x12InputEntry 1 } wtWebio577xxEA12x12InputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebio577xxEA12x12InputEntry 2 } wtWebio577xxEA12x12InputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtWebio577xxEA12x12InputEntry 3 } wtWebio577xxEA12x12InputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of a single input bit, 0-OFF, 1-ON." ::= { wtWebio577xxEA12x12InputEntry 4 } wtWebio577xxEA12x12InputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3: Digital outputs 8-11 OCTET 4, Bit 0-7: Digital outputs 0-7" ::= { wtWebio577xxEA12x12InOut 4 } -- Output Interface Table wtWebio577xxEA12x12OutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x12OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtWebio577xxEA12x12InOut 5 } wtWebio577xxEA12x12OutputEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x12OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtWebio577xxEA12x12OutputNo } ::= { wtWebio577xxEA12x12OutputTable 1 } WtWebio577xxEA12x12OutputEntry ::= SEQUENCE { wtWebio577xxEA12x12OutputNo INTEGER, wtWebio577xxEA12x12OutputState INTEGER } wtWebio577xxEA12x12OutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtWebio577xxEA12x12OutputEntry 1 } wtWebio577xxEA12x12OutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of a single output bit, 0-OFF, 1-ON." ::= { wtWebio577xxEA12x12OutputEntry 2 } wtWebio577xxEA12x12OutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3: Digital outputs 8-11 OCTET 4, Bit 0-7: Digital outputs 0-7" ::= { wtWebio577xxEA12x12InOut 6 } wtWebio577xxEA12x12SetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : Bit 0-3: Mask for digital outputs 8-11 OCTET 4 : Bit 0-7: Mask for digital outputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : Bit 0-3: Mask for digital outputs 8-11 OCTET 8 : Bit 0-7: Mask for digital outputs 0-7" ::= { wtWebio577xxEA12x12InOut 7 } -- wtWebio577xxEA12x12SessCntrl Group -------------------------------- wtWebio577xxEA12x12SessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebio577xxEA12x12SessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebio577xxEA12x12SessCntrl 1 } wtWebio577xxEA12x12SessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebio577xxEA12x12SessCntrl 2 } wtWebio577xxEA12x12SessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebio577xxEA12x12SessCntrl 3 } wtWebio577xxEA12x12SessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebio577xxEA12x12SessCntrl 4 } wtWebio577xxEA12x12SessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebio577xxEA12x12SessCntrl 5 } -- wtWebio577xxEA12x12Text Group ------------------------ wtWebio577xxEA12x12DeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebio577xxEA12x12Text 1 } wtWebio577xxEA12x12DeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebio577xxEA12x12Text 2 } wtWebio577xxEA12x12DeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebio577xxEA12x12Text 3 } wtWebio577xxEA12x12DeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebio577xxEA12x12Text 4 } -- wtWebio577xxEA12x12TimeZone Group ---------------------------- wtWebio577xxEA12x12TzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebio577xxEA12x12TimeZone 1 } wtWebio577xxEA12x12TzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebio577xxEA12x12TimeZone 2 } wtWebio577xxEA12x12TzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebio577xxEA12x12TimeZone 3 } wtWebio577xxEA12x12StTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebio577xxEA12x12TimeZone 4 } wtWebio577xxEA12x12StTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebio577xxEA12x12TimeZone 5 } wtWebio577xxEA12x12StTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebio577xxEA12x12TimeZone 6 } wtWebio577xxEA12x12StTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA12x12StartMonth-January(1), wtWebio577xxEA12x12StartMonth-February(2), wtWebio577xxEA12x12StartMonth-March(3), wtWebio577xxEA12x12StartMonth-April(4), wtWebio577xxEA12x12StartMonth-May(5), wtWebio577xxEA12x12StartMonth-June(6), wtWebio577xxEA12x12StartMonth-July(7), wtWebio577xxEA12x12StartMonth-August(8), wtWebio577xxEA12x12StartMonth-September(9), wtWebio577xxEA12x12StartMonth-October(10), wtWebio577xxEA12x12StartMonth-November(11), wtWebio577xxEA12x12StartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebio577xxEA12x12TimeZone 7 } wtWebio577xxEA12x12StTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA12x12StartMode-first(1), wtWebio577xxEA12x12StartMode-second(2), wtWebio577xxEA12x12StartMode-third(3), wtWebio577xxEA12x12StartMode-fourth(4), wtWebio577xxEA12x12StartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebio577xxEA12x12TimeZone 8 } wtWebio577xxEA12x12StTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA12x12StartWday-Sunday(1), wtWebio577xxEA12x12StartWday-Monday(2), wtWebio577xxEA12x12StartWday-Tuesday(3), wtWebio577xxEA12x12StartWday-Thursday(4), wtWebio577xxEA12x12StartWday-Wednesday(5), wtWebio577xxEA12x12StartWday-Friday(6), wtWebio577xxEA12x12StartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebio577xxEA12x12TimeZone 9 } wtWebio577xxEA12x12StTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebio577xxEA12x12TimeZone 10 } wtWebio577xxEA12x12StTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebio577xxEA12x12TimeZone 11 } wtWebio577xxEA12x12StTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA12x12StopMonth-January(1), wtWebio577xxEA12x12StopMonth-February(2), wtWebio577xxEA12x12StopMonth-March(3), wtWebio577xxEA12x12StopMonth-April(4), wtWebio577xxEA12x12StopMonth-May(5), wtWebio577xxEA12x12StopMonth-June(6), wtWebio577xxEA12x12StopMonth-July(7), wtWebio577xxEA12x12StopMonth-August(8), wtWebio577xxEA12x12StopMonth-September(9), wtWebio577xxEA12x12StopMonth-October(10), wtWebio577xxEA12x12StopMonth-November(11), wtWebio577xxEA12x12StopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebio577xxEA12x12TimeZone 12 } wtWebio577xxEA12x12StTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA12x12StopMode-first(1), wtWebio577xxEA12x12StopMode-second(2), wtWebio577xxEA12x12StopMode-third(3), wtWebio577xxEA12x12StopMode-fourth(4), wtWebio577xxEA12x12StopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebio577xxEA12x12TimeZone 13 } wtWebio577xxEA12x12StTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA12x12StopWday-Sunday(1), wtWebio577xxEA12x12StopWday-Monday(2), wtWebio577xxEA12x12StopWday-Tuesday(3), wtWebio577xxEA12x12StopWday-Thursday(4), wtWebio577xxEA12x12StopWday-Wednesday(5), wtWebio577xxEA12x12StopWday-Friday(6), wtWebio577xxEA12x12StopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebio577xxEA12x12TimeZone 14 } wtWebio577xxEA12x12StTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebio577xxEA12x12TimeZone 15 } wtWebio577xxEA12x12StTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebio577xxEA12x12TimeZone 16 } -- wtWebio577xxEA12x12TimeServer Group ---------------------------- wtWebio577xxEA12x12TimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebio577xxEA12x12TimeServer 1 } wtWebio577xxEA12x12TimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebio577xxEA12x12TimeServer 2 } wtWebio577xxEA12x12TsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebio577xxEA12x12TimeServer 3 } wtWebio577xxEA12x12TsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebio577xxEA12x12TimeServer 4 } -- wtWebio577xxEA12x12DeviceClock Group ---------------------------- wtWebio577xxEA12x12ClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebio577xxEA12x12DeviceClock 1 } wtWebio577xxEA12x12ClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebio577xxEA12x12DeviceClock 2 } wtWebio577xxEA12x12ClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebio577xxEA12x12DeviceClock 3 } wtWebio577xxEA12x12ClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA12x12ClockMonth-January(1), wtWebio577xxEA12x12ClockMonth-February(2), wtWebio577xxEA12x12ClockMonth-March(3), wtWebio577xxEA12x12ClockMonth-April(4), wtWebio577xxEA12x12ClockMonth-May(5), wtWebio577xxEA12x12ClockMonth-June(6), wtWebio577xxEA12x12ClockMonth-July(7), wtWebio577xxEA12x12ClockMonth-August(8), wtWebio577xxEA12x12ClockMonth-September(9), wtWebio577xxEA12x12ClockMonth-October(10), wtWebio577xxEA12x12ClockMonth-November(11), wtWebio577xxEA12x12ClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebio577xxEA12x12DeviceClock 4 } wtWebio577xxEA12x12ClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebio577xxEA12x12DeviceClock 5 } -- wtWebio577xxEA12x12Network Group ------------------------ wtWebio577xxEA12x12IpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebio577xxEA12x12Network 1 } wtWebio577xxEA12x12SubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebio577xxEA12x12Network 2 } wtWebio577xxEA12x12Gateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebio577xxEA12x12Network 3 } wtWebio577xxEA12x12DnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebio577xxEA12x12Network 4 } wtWebio577xxEA12x12DnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebio577xxEA12x12Network 5 } wtWebio577xxEA12x12AddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebio577xxEA12x12Network 6 } -- wtWebio577xxEA12x12HTTP Group -------------------------------- wtWebio577xxEA12x12Startup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebio577xxEA12x12HTTP 1 } wtWebio577xxEA12x12GetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebio577xxEA12x12HTTP 2 } wtWebio577xxEA12x12HttpInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebio577xxEA12x12HTTP 3 } wtWebio577xxEA12x12HttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebio577xxEA12x12HTTP 4 } -- wtWebio577xxEA12x12Mail Group -------------------------------- wtWebio577xxEA12x12MailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebio577xxEA12x12Mail 1 } wtWebio577xxEA12x12MailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebio577xxEA12x12Mail 2 } wtWebio577xxEA12x12MailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebio577xxEA12x12Mail 3 } wtWebio577xxEA12x12MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebio577xxEA12x12Mail 4 } wtWebio577xxEA12x12MailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebio577xxEA12x12Mail 5 } wtWebio577xxEA12x12MailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebio577xxEA12x12Mail 6 } wtWebio577xxEA12x12MailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebio577xxEA12x12Mail 7 } wtWebio577xxEA12x12MailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebio577xxEA12x12Mail 8 } -- wtWebio577xxEA12x12Snmp Group -------------------------------- wtWebio577xxEA12x12SnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebio577xxEA12x12SNMP 1 } wtWebio577xxEA12x12SnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebio577xxEA12x12SNMP 2 } wtWebio577xxEA12x12SnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebio577xxEA12x12SNMP 3 } wtWebio577xxEA12x12SnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebio577xxEA12x12SNMP 4 } wtWebio577xxEA12x12SnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtWebio577xxEA12x12SNMP 5 } wtWebio577xxEA12x12SnmpSystemTrapManagerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the system trap." ::= { wtWebio577xxEA12x12SNMP 6 } -- wtWebio577xxEA12x12UDP Group -------------------------------- wtWebio577xxEA12x12UdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebio577xxEA12x12UDP 1 } wtWebio577xxEA12x12UdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebio577xxEA12x12UDP 2 } wtWebio577xxEA12x12UdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebio577xxEA12x12UDP 3 } -- wtWebio577xxEA12x12Binary Group -------------------------------- wtWebio577xxEA12x12BinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebio577xxEA12x12Binary 1 } -- Binary Interface Table wtWebio577xxEA12x12BinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x12BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebio577xxEA12x12Binary 2 } wtWebio577xxEA12x12BinaryIfEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x12BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebio577xxEA12x12BinaryModeNo } ::= { wtWebio577xxEA12x12BinaryIfTable 1 } WtWebio577xxEA12x12BinaryIfEntry ::= SEQUENCE { wtWebio577xxEA12x12BinaryModeNo INTEGER } wtWebio577xxEA12x12BinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebio577xxEA12x12BinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebio577xxEA12x12BinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x12BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebio577xxEA12x12Binary 3 } wtWebio577xxEA12x12BinaryEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x12BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebio577xxEA12x12BinaryModeNo } ::= { wtWebio577xxEA12x12BinaryTable 1 } WtWebio577xxEA12x12BinaryEntry ::= SEQUENCE { wtWebio577xxEA12x12BinaryOperationMode OCTET STRING, wtWebio577xxEA12x12BinaryTcpServerLocalPort INTEGER, wtWebio577xxEA12x12BinaryTcpServerInputTrigger OCTET STRING, wtWebio577xxEA12x12BinaryTcpServerApplicationMode OCTET STRING, wtWebio577xxEA12x12BinaryTcpClientLocalPort INTEGER, wtWebio577xxEA12x12BinaryTcpClientServerPort INTEGER, wtWebio577xxEA12x12BinaryTcpClientServerIpAddr OCTET STRING, wtWebio577xxEA12x12BinaryTcpClientServerPassword OCTET STRING, wtWebio577xxEA12x12BinaryTcpClientInactivity INTEGER, wtWebio577xxEA12x12BinaryTcpClientInputTrigger OCTET STRING, wtWebio577xxEA12x12BinaryTcpClientInterval INTEGER, wtWebio577xxEA12x12BinaryTcpClientApplicationMode OCTET STRING, wtWebio577xxEA12x12BinaryUdpPeerLocalPort INTEGER, wtWebio577xxEA12x12BinaryUdpPeerRemotePort INTEGER, wtWebio577xxEA12x12BinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebio577xxEA12x12BinaryUdpPeerInputTrigger OCTET STRING, wtWebio577xxEA12x12BinaryUdpPeerInterval INTEGER, wtWebio577xxEA12x12BinaryUdpPeerApplicationMode OCTET STRING, wtWebio577xxEA12x12BinaryConnectedPort INTEGER, wtWebio577xxEA12x12BinaryConnectedIpAddr IpAddress, wtWebio577xxEA12x12BinaryTcpServerClientHttpPort INTEGER, wtWebio577xxEA12x12BinaryTcpClientServerHttpPort INTEGER, wtWebio577xxEA12x12BinaryTcpClientServerUserName OCTET STRING } wtWebio577xxEA12x12BinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebio577xxEA12x12BinaryEntry 1 } wtWebio577xxEA12x12BinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebio577xxEA12x12BinaryEntry 2 } wtWebio577xxEA12x12BinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebio577xxEA12x12BinaryEntry 3 } wtWebio577xxEA12x12BinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebio577xxEA12x12BinaryEntry 4 } wtWebio577xxEA12x12BinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebio577xxEA12x12BinaryEntry 5 } wtWebio577xxEA12x12BinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebio577xxEA12x12BinaryEntry 6 } wtWebio577xxEA12x12BinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebio577xxEA12x12BinaryEntry 7 } wtWebio577xxEA12x12BinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebio577xxEA12x12BinaryEntry 8 } wtWebio577xxEA12x12BinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebio577xxEA12x12BinaryEntry 9 } wtWebio577xxEA12x12BinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebio577xxEA12x12BinaryEntry 10 } wtWebio577xxEA12x12BinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebio577xxEA12x12BinaryEntry 11 } wtWebio577xxEA12x12BinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebio577xxEA12x12BinaryEntry 12 } wtWebio577xxEA12x12BinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebio577xxEA12x12BinaryEntry 13 } wtWebio577xxEA12x12BinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebio577xxEA12x12BinaryEntry 14 } wtWebio577xxEA12x12BinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebio577xxEA12x12BinaryEntry 15 } wtWebio577xxEA12x12BinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3: Digital inputs 8-11 OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebio577xxEA12x12BinaryEntry 16 } wtWebio577xxEA12x12BinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebio577xxEA12x12BinaryEntry 17 } wtWebio577xxEA12x12BinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebio577xxEA12x12BinaryEntry 18 } wtWebio577xxEA12x12BinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebio577xxEA12x12BinaryEntry 19 } wtWebio577xxEA12x12BinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebio577xxEA12x12BinaryEntry 20 } wtWebio577xxEA12x12BinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebio577xxEA12x12BinaryEntry 21 } wtWebio577xxEA12x12BinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebio577xxEA12x12BinaryEntry 22 } wtWebio577xxEA12x12BinaryTcpClientServerUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "User Name to login at the remote server, if authentication needed." ::= { wtWebio577xxEA12x12BinaryEntry 23 } -- wtWebio577xxEA12x12Syslog Group -------------------------------- wtWebio577xxEA12x12SyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebio577xxEA12x12Syslog 1 } wtWebio577xxEA12x12SyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebio577xxEA12x12Syslog 2 } wtWebio577xxEA12x12SyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebio577xxEA12x12Syslog 3 } wtWebio577xxEA12x12SyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebio577xxEA12x12Syslog 4 } -- wtWebio577xxEA12x12FTP Group -------------------------------- wtWebio577xxEA12x12FTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebio577xxEA12x12FTP 1 } wtWebio577xxEA12x12FTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebio577xxEA12x12FTP 2 } wtWebio577xxEA12x12FTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebio577xxEA12x12FTP 3 } wtWebio577xxEA12x12FTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebio577xxEA12x12FTP 4 } wtWebio577xxEA12x12FTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebio577xxEA12x12FTP 5 } wtWebio577xxEA12x12FTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebio577xxEA12x12FTP 6 } wtWebio577xxEA12x12FTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebio577xxEA12x12FTP 7 } -- wtWebio577xxEA12x12MQTT Group -------------------------------- wtWebio577xxEA12x12MQTTEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 7 enables MQTT: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-6: unused Bit 7 : MQTT enable" ::= { wtWebio577xxEA12x12MQTT 1 } wtWebio577xxEA12x12MQTTBrockerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP-address of the MQTT-Server." ::= { wtWebio577xxEA12x12MQTT 2 } wtWebio577xxEA12x12MQTTUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT login user name." ::= { wtWebio577xxEA12x12MQTT 3 } wtWebio577xxEA12x12MQTTPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT login password." ::= { wtWebio577xxEA12x12MQTT 4 } wtWebio577xxEA12x12MQTTLocalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Local port number." ::= { wtWebio577xxEA12x12MQTT 5 } wtWebio577xxEA12x12MQTTBrokerServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Server port number." ::= { wtWebio577xxEA12x12MQTT 6 } wtWebio577xxEA12x12MQTTInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Ping intervall, if no data has to be send: time in seconds." ::= { wtWebio577xxEA12x12MQTT 7 } wtWebio577xxEA12x12MQTTLastWillEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activate MQTT LastWill message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will enable" ::= { wtWebio577xxEA12x12MQTT 8 } wtWebio577xxEA12x12MQTTLastWillTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will Topic." ::= { wtWebio577xxEA12x12MQTT 9 } wtWebio577xxEA12x12MQTTLastWillMsg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will message." ::= { wtWebio577xxEA12x12MQTT 10 } wtWebio577xxEA12x12MQTTLastWillQoS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded MQTT Publish QoS: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused" ::= { wtWebio577xxEA12x12MQTT 11 } wtWebio577xxEA12x12MQTTLastWillRetain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded MQTT Publish Retain properties: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused" ::= { wtWebio577xxEA12x12MQTT 12 } wtWebio577xxEA12x12MQTTLastWillConnectEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activate MQTT LastWill Connect message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will connect message enable" ::= { wtWebio577xxEA12x12MQTT 13 } wtWebio577xxEA12x12MQTTLastWillConnectMsg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will Connect message will be send with the QoS and Retain settings of the LastWill message." ::= { wtWebio577xxEA12x12MQTT 14 } -- wtWebio577xxEA1x1REST Group -------------------------------- wtWebio577xxEA12x12RESTEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activates REST: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : REST enable" ::= { wtWebio577xxEA12x12REST 1 } wtWebio577xxEA12x12RESTDigestAuthEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activates Digest-Authentification: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Digest Auth enable" ::= { wtWebio577xxEA12x12REST 2 } -- wtWebio577xxEA12x12OutputMode Group -------------------------------- -- OutputMode Table wtWebio577xxEA12x12OutputModeTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x12OutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of output mode configurations dependent on the output indices." ::= { wtWebio577xxEA12x12OutputMode 1 } wtWebio577xxEA12x12OutputModeEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x12OutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output mode configurations of the individual outputs." INDEX { wtWebio577xxEA12x12OutputNo } ::= { wtWebio577xxEA12x12OutputModeTable 1 } WtWebio577xxEA12x12OutputModeEntry ::= SEQUENCE { wtWebio577xxEA12x12OutputModeBit OCTET STRING } wtWebio577xxEA12x12OutputModeBit OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebio577xxEA12x12OutputModeEntry 1 } wtWebio577xxEA12x12SafetyTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined." ::= { wtWebio577xxEA12x12OutputMode 2 } -- wtWebio577xxEA12x12Alarm Group ---------------------------- wtWebio577xxEA12x12AlarmCount OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebio577xxEA12x12Alarm 1 } -- Alarm Interface Table wtWebio577xxEA12x12AlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x12AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebio577xxEA12x12Alarm 2 } wtWebio577xxEA12x12AlarmIfEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x12AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebio577xxEA12x12AlarmNo } ::= { wtWebio577xxEA12x12AlarmIfTable 1 } WtWebio577xxEA12x12AlarmIfEntry ::= SEQUENCE { wtWebio577xxEA12x12AlarmNo INTEGER } wtWebio577xxEA12x12AlarmNo OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtWebio577xxEA12x12AlarmIfEntry 1 } -- Alarm Table wtWebio577xxEA12x12AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x12AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebio577xxEA12x12Alarm 3 } wtWebio577xxEA12x12AlarmEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x12AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebio577xxEA12x12AlarmNo } ::= { wtWebio577xxEA12x12AlarmTable 1 } WtWebio577xxEA12x12AlarmEntry ::= SEQUENCE { wtWebio577xxEA12x12AlarmInputTrigger OCTET STRING, wtWebio577xxEA12x12AlarmOutputTrigger OCTET STRING, wtWebio577xxEA12x12AlarmSystemTrigger OCTET STRING, wtWebio577xxEA12x12AlarmMaxCounterValue OCTET STRING, wtWebio577xxEA12x12AlarmInterval OCTET STRING, wtWebio577xxEA12x12AlarmEnable OCTET STRING, wtWebio577xxEA12x12AlarmMailAddr OCTET STRING, wtWebio577xxEA12x12AlarmMailSubject OCTET STRING, wtWebio577xxEA12x12AlarmMailText OCTET STRING, wtWebio577xxEA12x12AlarmSnmpManagerIP OCTET STRING, wtWebio577xxEA12x12AlarmSnmpTrapText OCTET STRING, wtWebio577xxEA12x12AlarmUdpIpAddr OCTET STRING, wtWebio577xxEA12x12AlarmUdpPort INTEGER, wtWebio577xxEA12x12AlarmUdpText OCTET STRING, wtWebio577xxEA12x12AlarmTcpIpAddr OCTET STRING, wtWebio577xxEA12x12AlarmTcpPort INTEGER, wtWebio577xxEA12x12AlarmTcpText OCTET STRING, wtWebio577xxEA12x12AlarmSyslogIpAddr OCTET STRING, wtWebio577xxEA12x12AlarmSyslogPort INTEGER, wtWebio577xxEA12x12AlarmSyslogText OCTET STRING, wtWebio577xxEA12x12AlarmFtpDataPort OCTET STRING, wtWebio577xxEA12x12AlarmFtpFileName OCTET STRING, wtWebio577xxEA12x12AlarmFtpText OCTET STRING, wtWebio577xxEA12x12AlarmFtpOption OCTET STRING, wtWebio577xxEA12x12AlarmTimerCron OCTET STRING, wtWebio577xxEA12x12AlarmMailReleaseSubject OCTET STRING, wtWebio577xxEA12x12AlarmMailReleaseText OCTET STRING, wtWebio577xxEA12x12AlarmSnmpTrapReleaseText OCTET STRING, wtWebio577xxEA12x12AlarmUdpReleaseText OCTET STRING, wtWebio577xxEA12x12AlarmTcpReleaseText OCTET STRING, wtWebio577xxEA12x12AlarmSyslogReleaseText OCTET STRING, wtWebio577xxEA12x12AlarmFtpReleaseText OCTET STRING, wtWebio577xxEA12x12AlarmGlobalEnable OCTET STRING, wtWebio577xxEA12x12AlarmCombinationLogic OCTET STRING, wtWebio577xxEA12x12AlarmTrgMqttTopic OCTET STRING, wtWebio577xxEA12x12AlarmTrgMqttTopicText OCTET STRING, wtWebio577xxEA12x12AlarmHttpReqAuthEnable OCTET STRING, wtWebio577xxEA12x12AlarmHttpReqAuthUser OCTET STRING, wtWebio577xxEA12x12AlarmHttpReqAuthPassword OCTET STRING, wtWebio577xxEA12x12AlarmHttpReqSetUrl OCTET STRING, wtWebio577xxEA12x12AlarmHttpReqClearUrl OCTET STRING, wtWebio577xxEA12x12AlarmHttpReqServerPort INTEGER, wtWebio577xxEA12x12AlarmMqttTopicPath OCTET STRING, wtWebio577xxEA12x12AlarmMqttTopicSetTopic OCTET STRING, wtWebio577xxEA12x12AlarmMqttTopicClear OCTET STRING, wtWebio577xxEA12x12AlarmSetOutputsOwn OCTET STRING, wtWebio577xxEA12x12AlarmSetOutputsServerIp OCTET STRING, wtWebio577xxEA12x12AlarmSetOutputsServerPort INTEGER, wtWebio577xxEA12x12AlarmSetOutputsServerPassword OCTET STRING, wtWebio577xxEA12x12AlarmSetOutputsServerOutputs OCTET STRING, wtWebio577xxEA12x12AlarmSetOutputsDest OCTET STRING, wtWebio577xxEA12x12AlarmSnmpManagerPort INTEGER, wtWebio577xxEA12x12AlarmMqttQoS OCTET STRING, wtWebio577xxEA12x12AlarmMqttRetain OCTET STRING } wtWebio577xxEA12x12AlarmInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3, Bit 0-3: Mask for digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Mask for digital inputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7, Bit 0-3: Level of digital inputs 8-11 Bit 4-7: unused OCTET 8, Bit 0-7: Level of digital inputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unsused OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11 Bit 12-15 : unused OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7" ::= { wtWebio577xxEA12x12AlarmEntry 1 } wtWebio577xxEA12x12AlarmOutputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3, Bit 0-3: Mask for digital outputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Mask for digital outputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7, Bit 0-3: Level of digital outputs 8-11 Bit 4-7: unused OCTET 8, Bit 0-7: Level of digital outputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11 Bit 12-15 : unused OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7" ::= { wtWebio577xxEA12x12AlarmEntry 2 } wtWebio577xxEA12x12AlarmSystemTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control" ::= { wtWebio577xxEA12x12AlarmEntry 3 } wtWebio577xxEA12x12AlarmMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebio577xxEA12x12AlarmInputTrigger are not considered." ::= { wtWebio577xxEA12x12AlarmEntry 4 } wtWebio577xxEA12x12AlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebio577xxEA12x12AlarmEntry 5 } wtWebio577xxEA12x12AlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Bit 0: UDP enable Bit1-7: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable Bit 3: Syslog Messages enable Bit 4: FTP enable Bit 5: HTTP Request enable Bit 6 MQTT Publish enable Bit 7: Set Outputs" ::= { wtWebio577xxEA12x12AlarmEntry 6 } wtWebio577xxEA12x12AlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebio577xxEA12x12AlarmEntry 7 } wtWebio577xxEA12x12AlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebio577xxEA12x12AlarmEntry 8 } wtWebio577xxEA12x12AlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebio577xxEA12x12AlarmEntry 9 } wtWebio577xxEA12x12AlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebio577xxEA12x12AlarmEntry 10 } wtWebio577xxEA12x12AlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebio577xxEA12x12AlarmEntry 11 } wtWebio577xxEA12x12AlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebio577xxEA12x12AlarmEntry 12 } wtWebio577xxEA12x12AlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebio577xxEA12x12AlarmEntry 13 } wtWebio577xxEA12x12AlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebio577xxEA12x12AlarmEntry 14 } wtWebio577xxEA12x12AlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebio577xxEA12x12AlarmEntry 15 } wtWebio577xxEA12x12AlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebio577xxEA12x12AlarmEntry 16 } wtWebio577xxEA12x12AlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebio577xxEA12x12AlarmEntry 17 } wtWebio577xxEA12x12AlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebio577xxEA12x12AlarmEntry 18 } wtWebio577xxEA12x12AlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebio577xxEA12x12AlarmEntry 19 } wtWebio577xxEA12x12AlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebio577xxEA12x12AlarmEntry 20 } wtWebio577xxEA12x12AlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebio577xxEA12x12AlarmEntry 21 } wtWebio577xxEA12x12AlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebio577xxEA12x12AlarmEntry 22 } wtWebio577xxEA12x12AlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebio577xxEA12x12AlarmEntry 23 } wtWebio577xxEA12x12AlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebio577xxEA12x12AlarmEntry 24 } wtWebio577xxEA12x12AlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebio577xxEA12x12AlarmEntry 25 } wtWebio577xxEA12x12AlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebio577xxEA12x12AlarmEntry 26 } wtWebio577xxEA12x12AlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebio577xxEA12x12AlarmEntry 27 } wtWebio577xxEA12x12AlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebio577xxEA12x12AlarmEntry 28 } wtWebio577xxEA12x12AlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebio577xxEA12x12AlarmEntry 29 } wtWebio577xxEA12x12AlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebio577xxEA12x12AlarmEntry 30 } wtWebio577xxEA12x12AlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebio577xxEA12x12AlarmEntry 31 } wtWebio577xxEA12x12AlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebio577xxEA12x12AlarmEntry 32 } wtWebio577xxEA12x12AlarmGlobalEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm activation: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Alarm enable" ::= { wtWebio577xxEA12x12AlarmEntry 34 } wtWebio577xxEA12x12AlarmCombinationLogic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded logic, all Input/Output-trigger will be combined: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : OR Bit 0 : AND" ::= { wtWebio577xxEA12x12AlarmEntry 58 } wtWebio577xxEA12x12AlarmTrgMqttTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT subscribe topic." ::= { wtWebio577xxEA12x12AlarmEntry 59 } wtWebio577xxEA12x12AlarmTrgMqttTopicText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Receiving this text from the MQTT Broker, Alarm will be triggered." ::= { wtWebio577xxEA12x12AlarmEntry 60 } wtWebio577xxEA12x12AlarmHttpReqAuthEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable" ::= { wtWebio577xxEA12x12AlarmEntry 61 } wtWebio577xxEA12x12AlarmHttpReqAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: User" ::= { wtWebio577xxEA12x12AlarmEntry 62 } wtWebio577xxEA12x12AlarmHttpReqAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Password" ::= { wtWebio577xxEA12x12AlarmEntry 63 } wtWebio577xxEA12x12AlarmHttpReqSetUrl OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Set URL" ::= { wtWebio577xxEA12x12AlarmEntry 64 } wtWebio577xxEA12x12AlarmHttpReqClearUrl OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Clear URL" ::= { wtWebio577xxEA12x12AlarmEntry 65 } wtWebio577xxEA12x12AlarmHttpReqServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Server Port" ::= { wtWebio577xxEA12x12AlarmEntry 66 } wtWebio577xxEA12x12AlarmMqttTopicPath OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic path" ::= { wtWebio577xxEA12x12AlarmEntry 67 } wtWebio577xxEA12x12AlarmMqttTopicSetTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic SET message" ::= { wtWebio577xxEA12x12AlarmEntry 68 } wtWebio577xxEA12x12AlarmMqttTopicClear OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic CLEAR message" ::= { wtWebio577xxEA12x12AlarmEntry 69 } wtWebio577xxEA12x12AlarmSetOutputsOwn OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : Bit 0-3: Level of digital outputs 8-11 OCTET 4 : Bit 0-7: Mask for digital outputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : Bit 0-3: Level of digital outputs 8-11 OCTET 8 : Bit 0-7: Level of digital outputs 0-7 OCTETS 9-12 are unused." ::= { wtWebio577xxEA12x12AlarmEntry 70 } wtWebio577xxEA12x12AlarmSetOutputsServerIp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Outputs: Server IP Address" ::= { wtWebio577xxEA12x12AlarmEntry 71 } wtWebio577xxEA12x12AlarmSetOutputsServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Set Outputs: Server Port" ::= { wtWebio577xxEA12x12AlarmEntry 72 } wtWebio577xxEA12x12AlarmSetOutputsServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Outputs: Server Pasword" ::= { wtWebio577xxEA12x12AlarmEntry 73 } wtWebio577xxEA12x12AlarmSetOutputsServerOutputs OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : Bit 0-3: Level of digital outputs 8-11 OCTET 4 : Bit 0-7: Mask for digital outputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : Bit 0-3: Level of digital outputs 8-11 OCTET 8 : Bit 0-7: Level of digital outputs 0-7 OCTETS 9-12 are unused." ::= { wtWebio577xxEA12x12AlarmEntry 74 } wtWebio577xxEA12x12AlarmSetOutputsDest OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Bit 0 = LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : set outputs of remote server. Bit 0 : set outputs of this WEB-IO" ::= { wtWebio577xxEA12x12AlarmEntry 75 } wtWebio577xxEA12x12AlarmSnmpManagerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebio577xxEA12x12AlarmEntry 76 } wtWebio577xxEA12x12AlarmMqttQoS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused" ::= { wtWebio577xxEA12x12AlarmEntry 77 } wtWebio577xxEA12x12AlarmMqttRetain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused" ::= { wtWebio577xxEA12x12AlarmEntry 78 } -- wtWebio577xxEA12x12LoadControl ---------------------------- wtWebio577xxEA12x12LoadControlView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Here the result of automatic load control can be read. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: Bit 0-3: outputs 8-11 Octet 4: Bit 0-7: outputs 0-7." ::= { wtWebio577xxEA12x12Alarm 4 } wtWebio577xxEA12x12LCShutDownView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Here the result of the automatic load control shut down can be read. All outputs remain switched of, until a zero is written into this variable. But previously all loads should be inspected. High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason. If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair. All controlled output could be identified reading the variable wtWebio577xxEA12x12LoadControlEnable. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: Bit 0-3: outputs 8-11 Octet 4: Bit 0-7: outputs 0-7." ::= { wtWebio577xxEA12x12Alarm 5 } -- wtWebio577xxEA12x12Ports Group ---------------------------- -- Input Port Table wtWebio577xxEA12x12InputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x12InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebio577xxEA12x12Ports 1 } wtWebio577xxEA12x12InputPortEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x12InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebio577xxEA12x12InputNo } ::= { wtWebio577xxEA12x12InputPortTable 1 } WtWebio577xxEA12x12InputPortEntry ::= SEQUENCE { wtWebio577xxEA12x12PortInputName OCTET STRING, wtWebio577xxEA12x12PortInputText OCTET STRING, wtWebio577xxEA12x12PortInputMode OCTET STRING, wtWebio577xxEA12x12PortInputFilter INTEGER, wtWebio577xxEA12x12PortInputBicountPulsePolarity OCTET STRING, wtWebio577xxEA12x12PortInputBicountInactivTimeout INTEGER } wtWebio577xxEA12x12PortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebio577xxEA12x12InputPortEntry 1 } wtWebio577xxEA12x12PortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebio577xxEA12x12InputPortEntry 2 } wtWebio577xxEA12x12PortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. Selection for input 0-1: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Bidirectional counter enable Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable" ::= { wtWebio577xxEA12x12InputPortEntry 3 } wtWebio577xxEA12x12PortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebio577xxEA12x12InputPortEntry 4 } wtWebio577xxEA12x12PortInputBicountPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebio577xxEA12x12InputPortEntry 5 } wtWebio577xxEA12x12PortInputBicountInactivTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored." ::= { wtWebio577xxEA12x12InputPortEntry 6 } -- Output Port Table wtWebio577xxEA12x12OutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x12OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtWebio577xxEA12x12Ports 2 } wtWebio577xxEA12x12OutputPortEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x12OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtWebio577xxEA12x12OutputNo } ::= { wtWebio577xxEA12x12OutputPortTable 1 } WtWebio577xxEA12x12OutputPortEntry ::= SEQUENCE { wtWebio577xxEA12x12PortOutputName OCTET STRING, wtWebio577xxEA12x12PortOutputText OCTET STRING, wtWebio577xxEA12x12PortOutputGroupMode OCTET STRING, wtWebio577xxEA12x12PortOutputSafetyState OCTET STRING, wtWebio577xxEA12x12PortLogicInputMask OCTET STRING, wtWebio577xxEA12x12PortLogicInputInverter OCTET STRING, wtWebio577xxEA12x12PortLogicFunction OCTET STRING, wtWebio577xxEA12x12PortLogicOutputInverter OCTET STRING, wtWebio577xxEA12x12PortPulseDuration INTEGER, wtWebio577xxEA12x12PortPulsePolarity OCTET STRING } wtWebio577xxEA12x12PortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtWebio577xxEA12x12OutputPortEntry 1 } wtWebio577xxEA12x12PortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtWebio577xxEA12x12OutputPortEntry 2 } wtWebio577xxEA12x12PortOutputGroupMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one output bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for outputs 0-3: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 0,1,2,3 disconnected (default) Bit 1 : outputs 0+1, 2+3 connected Bit 2 : outputs 0+1+2+3 connected Bit 3-7 : unused Selection for outputs 4-7: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 4, 5, 6, 7 disconnected (default) Bit 1 : outputs 4+5, 6+7 connected Bit 2 : outputs 4+5+6+7 connected Bit 3-7 : unused Selection for outputs 8-11: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 8, 9, 10, 11 disconnected (default) Bit 1 : outputs 8+9, 10+11 connected Bit 2 : outputs 8+9+10+11 connected Bit 3-7 : unused" ::= { wtWebio577xxEA12x12OutputPortEntry 3 } wtWebio577xxEA12x12PortOutputSafetyState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 Bit 4-7: unused Bit 0-3: Mask for digital output 8-11 OCTET 4 Bit 0-7: Mask for digital output 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 Bit 4-7: Unused Bit 0-3: Level of digital output 8-11 OCTET 8 Bit 0-7: Level of digital output 0-7" ::= { wtWebio577xxEA12x12OutputPortEntry 4 } wtWebio577xxEA12x12PortLogicInputMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebio577xxEA12x12PortLogicInputMask) 2. Inverting inputs if necessary (wtWebio577xxEA12x12PortLogicInputInverter) 3. Logical combination (wtWebio577xxEA12x12PortLogicFunction) 4. Inverting the result if necessary (wtWebio577xxEA12x12PortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : inputs 8-11 OCTET 4: Bit 0-7 : inputs 0-7" ::= { wtWebio577xxEA12x12OutputPortEntry 5 } wtWebio577xxEA12x12PortLogicInputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : inputs 8-11 OCTET 4: Bit 0-7 : inputs 0-7" ::= { wtWebio577xxEA12x12OutputPortEntry 6 } wtWebio577xxEA12x12PortLogicFunction OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused" ::= { wtWebio577xxEA12x12OutputPortEntry 7 } wtWebio577xxEA12x12PortLogicOutputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : Output Inverter enable 8-11 OCTET 4: Bit 0-7 : Output Inverter enable 0-7" ::= { wtWebio577xxEA12x12OutputPortEntry 8 } wtWebio577xxEA12x12PortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtWebio577xxEA12x12OutputPortEntry 9 } wtWebio577xxEA12x12PortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtWebio577xxEA12x12PortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebio577xxEA12x12OutputPortEntry 10 } -- wtWebio577xxEA12x12Manufact Group ---------------------------- wtWebio577xxEA12x12MfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebio577xxEA12x12Manufact 1 } wtWebio577xxEA12x12MfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebio577xxEA12x12Manufact 2 } wtWebio577xxEA12x12MfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebio577xxEA12x12Manufact 3 } wtWebio577xxEA12x12MfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebio577xxEA12x12Manufact 4 } wtWebio577xxEA12x12MfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebio577xxEA12x12Manufact 5 } -- wtWebio577xxEA12x12Diag Group ---------------------------- wtWebio577xxEA12x12DiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebio577xxEA12x12Diag 1 } wtWebio577xxEA12x12DiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebio577xxEA12x12Diag 2 } wtWebio577xxEA12x12DiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebio577xxEA12x12DiagErrorMessage. Errors are numbered from 1 to wtWebio577xxEA12x12DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebio577xxEA12x12DiagErrorMessage." ::= { wtWebio577xxEA12x12Diag 3 } wtWebio577xxEA12x12DiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebio577xxEA12x12DiagErrorIndex as an index, the appropriate message is available." ::= { wtWebio577xxEA12x12Diag 4 } wtWebio577xxEA12x12DiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebio577xxEA12x12Diag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebio577xxEA12x12Alert1 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtWebio577xxEA12x12Alert2 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtWebio577xxEA12x12Alert3 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtWebio577xxEA12x12Alert4 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtWebio577xxEA12x12Alert5 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtWebio577xxEA12x12Alert6 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtWebio577xxEA12x12Alert7 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtWebio577xxEA12x12Alert8 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtWebio577xxEA12x12Alert9 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtWebio577xxEA12x12Alert10 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtWebio577xxEA12x12Alert11 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtWebio577xxEA12x12Alert12 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtWebio577xxEA12x12Alert13 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebio577xxEA12x12Alert14 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebio577xxEA12x12Alert15 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebio577xxEA12x12Alert16 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebio577xxEA12x12Alert17 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebio577xxEA12x12Alert18 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebio577xxEA12x12Alert19 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebio577xxEA12x12Alert20 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebio577xxEA12x12Alert21 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtWebio577xxEA12x12Alert22 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtWebio577xxEA12x12Alert23 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebio577xxEA12x12Alert24 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebio577xxEA12x12AlertDiag TRAP-TYPE ENTERPRISE wtWebio577xxEA12x12 VARIABLES { wtWebio577xxEA12x12DiagErrorIndex, wtWebio577xxEA12x12DiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebioEA12x12InOut Group ------------------------ wtWebioEA12x12Inputs OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtWebioEA12x12InOut 1 } wtWebioEA12x12Outputs OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent outputs." ::= { wtWebioEA12x12InOut 2 } -- Input Interface Table wtWebioEA12x12InputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x12InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebioEA12x12InOut 3 } wtWebioEA12x12InputEntry OBJECT-TYPE SYNTAX WtWebioEA12x12InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtWebioEA12x12InputNo } ::= { wtWebioEA12x12InputTable 1 } WtWebioEA12x12InputEntry ::= SEQUENCE { wtWebioEA12x12InputNo INTEGER, wtWebioEA12x12InputCounter INTEGER, wtWebioEA12x12InputCounterClear INTEGER, wtWebioEA12x12InputState INTEGER } wtWebioEA12x12InputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebioEA12x12InputEntry 1 } wtWebioEA12x12InputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebioEA12x12InputEntry 2 } wtWebioEA12x12InputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtWebioEA12x12InputEntry 3 } wtWebioEA12x12InputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of a single input bit, 0-OFF, 1-ON." ::= { wtWebioEA12x12InputEntry 4 } wtWebioEA12x12InputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital outputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital outputs 0-7" ::= { wtWebioEA12x12InOut 4 } -- Output Interface Table wtWebioEA12x12OutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x12OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtWebioEA12x12InOut 5 } wtWebioEA12x12OutputEntry OBJECT-TYPE SYNTAX WtWebioEA12x12OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtWebioEA12x12OutputNo } ::= { wtWebioEA12x12OutputTable 1 } WtWebioEA12x12OutputEntry ::= SEQUENCE { wtWebioEA12x12OutputNo INTEGER, wtWebioEA12x12OutputState INTEGER } wtWebioEA12x12OutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtWebioEA12x12OutputEntry 1 } wtWebioEA12x12OutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of a single output bit, 0-OFF, 1-ON." ::= { wtWebioEA12x12OutputEntry 2 } wtWebioEA12x12OutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital outputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital outputs 0-7" ::= { wtWebioEA12x12InOut 6 } wtWebioEA12x12SetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3, Bit 0-3: Mask for digital outputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Mask for digital outputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7, Bit 0-3: Level of digital outputs 8-11 Bit 4-7: unused OCTET 8, Bit 0-7: Level of digital outputs 0-7" ::= { wtWebioEA12x12InOut 7 } -- wtWebioEA12x12SessCntrl Group -------------------------------- wtWebioEA12x12SessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebioEA12x12SessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebioEA12x12SessCntrl 1 } wtWebioEA12x12SessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebioEA12x12SessCntrl 2 } wtWebioEA12x12SessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebioEA12x12SessCntrl 3 } wtWebioEA12x12SessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebioEA12x12SessCntrl 4 } wtWebioEA12x12SessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebioEA12x12SessCntrl 5 } -- wtWebioEA12x12Text Group ------------------------ wtWebioEA12x12DeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebioEA12x12Text 1 } wtWebioEA12x12DeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebioEA12x12Text 2 } wtWebioEA12x12DeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebioEA12x12Text 3 } wtWebioEA12x12DeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebioEA12x12Text 4 } -- wtWebioEA12x12TimeZone Group ---------------------------- wtWebioEA12x12TzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebioEA12x12TimeZone 1 } wtWebioEA12x12TzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebioEA12x12TimeZone 2 } wtWebioEA12x12TzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebioEA12x12TimeZone 3 } wtWebioEA12x12StTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebioEA12x12TimeZone 4 } wtWebioEA12x12StTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebioEA12x12TimeZone 5 } wtWebioEA12x12StTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebioEA12x12TimeZone 6 } wtWebioEA12x12StTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x12StartMonth-January(1), wtWebioEA12x12StartMonth-February(2), wtWebioEA12x12StartMonth-March(3), wtWebioEA12x12StartMonth-April(4), wtWebioEA12x12StartMonth-May(5), wtWebioEA12x12StartMonth-June(6), wtWebioEA12x12StartMonth-July(7), wtWebioEA12x12StartMonth-August(8), wtWebioEA12x12StartMonth-September(9), wtWebioEA12x12StartMonth-October(10), wtWebioEA12x12StartMonth-November(11), wtWebioEA12x12StartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebioEA12x12TimeZone 7 } wtWebioEA12x12StTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x12StartMode-first(1), wtWebioEA12x12StartMode-second(2), wtWebioEA12x12StartMode-third(3), wtWebioEA12x12StartMode-fourth(4), wtWebioEA12x12StartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebioEA12x12TimeZone 8 } wtWebioEA12x12StTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x12StartWday-Sunday(1), wtWebioEA12x12StartWday-Monday(2), wtWebioEA12x12StartWday-Tuesday(3), wtWebioEA12x12StartWday-Thursday(4), wtWebioEA12x12StartWday-Wednesday(5), wtWebioEA12x12StartWday-Friday(6), wtWebioEA12x12StartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebioEA12x12TimeZone 9 } wtWebioEA12x12StTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA12x12TimeZone 10 } wtWebioEA12x12StTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA12x12TimeZone 11 } wtWebioEA12x12StTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x12StopMonth-January(1), wtWebioEA12x12StopMonth-February(2), wtWebioEA12x12StopMonth-March(3), wtWebioEA12x12StopMonth-April(4), wtWebioEA12x12StopMonth-May(5), wtWebioEA12x12StopMonth-June(6), wtWebioEA12x12StopMonth-July(7), wtWebioEA12x12StopMonth-August(8), wtWebioEA12x12StopMonth-September(9), wtWebioEA12x12StopMonth-October(10), wtWebioEA12x12StopMonth-November(11), wtWebioEA12x12StopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebioEA12x12TimeZone 12 } wtWebioEA12x12StTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x12StopMode-first(1), wtWebioEA12x12StopMode-second(2), wtWebioEA12x12StopMode-third(3), wtWebioEA12x12StopMode-fourth(4), wtWebioEA12x12StopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebioEA12x12TimeZone 13 } wtWebioEA12x12StTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x12StopWday-Sunday(1), wtWebioEA12x12StopWday-Monday(2), wtWebioEA12x12StopWday-Tuesday(3), wtWebioEA12x12StopWday-Thursday(4), wtWebioEA12x12StopWday-Wednesday(5), wtWebioEA12x12StopWday-Friday(6), wtWebioEA12x12StopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebioEA12x12TimeZone 14 } wtWebioEA12x12StTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA12x12TimeZone 15 } wtWebioEA12x12StTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA12x12TimeZone 16 } -- wtWebioEA12x12TimeServer Group ---------------------------- wtWebioEA12x12TimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebioEA12x12TimeServer 1 } wtWebioEA12x12TimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebioEA12x12TimeServer 2 } wtWebioEA12x12TsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebioEA12x12TimeServer 3 } wtWebioEA12x12TsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebioEA12x12TimeServer 4 } -- wtWebioEA12x12DeviceClock Group ---------------------------- wtWebioEA12x12ClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebioEA12x12DeviceClock 1 } wtWebioEA12x12ClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebioEA12x12DeviceClock 2 } wtWebioEA12x12ClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebioEA12x12DeviceClock 3 } wtWebioEA12x12ClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x12ClockMonth-January(1), wtWebioEA12x12ClockMonth-February(2), wtWebioEA12x12ClockMonth-March(3), wtWebioEA12x12ClockMonth-April(4), wtWebioEA12x12ClockMonth-May(5), wtWebioEA12x12ClockMonth-June(6), wtWebioEA12x12ClockMonth-July(7), wtWebioEA12x12ClockMonth-August(8), wtWebioEA12x12ClockMonth-September(9), wtWebioEA12x12ClockMonth-October(10), wtWebioEA12x12ClockMonth-November(11), wtWebioEA12x12ClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebioEA12x12DeviceClock 4 } wtWebioEA12x12ClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebioEA12x12DeviceClock 5 } -- wtWebioEA12x12Network Group ------------------------ wtWebioEA12x12IpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebioEA12x12Network 1 } wtWebioEA12x12SubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebioEA12x12Network 2 } wtWebioEA12x12Gateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebioEA12x12Network 3 } wtWebioEA12x12DnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebioEA12x12Network 4 } wtWebioEA12x12DnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebioEA12x12Network 5 } wtWebioEA12x12AddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebioEA12x12Network 6 } -- wtWebioEA12x12HTTP Group -------------------------------- wtWebioEA12x12Startup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebioEA12x12HTTP 1 } wtWebioEA12x12GetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebioEA12x12HTTP 2 } wtWebioEA12x12HttpInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebioEA12x12HTTP 3 } wtWebioEA12x12HttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebioEA12x12HTTP 4 } -- wtWebioEA12x12Mail Group -------------------------------- wtWebioEA12x12MailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebioEA12x12Mail 1 } wtWebioEA12x12MailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebioEA12x12Mail 2 } wtWebioEA12x12MailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebioEA12x12Mail 3 } wtWebioEA12x12MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebioEA12x12Mail 4 } wtWebioEA12x12MailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebioEA12x12Mail 5 } wtWebioEA12x12MailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebioEA12x12Mail 6 } wtWebioEA12x12MailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebioEA12x12Mail 7 } wtWebioEA12x12MailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebioEA12x12Mail 8 } -- wtWebioEA12x12Snmp Group -------------------------------- wtWebioEA12x12SnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebioEA12x12SNMP 1 } wtWebioEA12x12SnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebioEA12x12SNMP 2 } wtWebioEA12x12SnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebioEA12x12SNMP 3 } wtWebioEA12x12SnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebioEA12x12SNMP 4 } wtWebioEA12x12SnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtWebioEA12x12SNMP 5 } -- wtWebioEA12x12Udp Group -------------------------------- wtWebioEA12x12UdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebioEA12x12UDP 1 } wtWebioEA12x12UdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebioEA12x12UDP 2 } wtWebioEA12x12UdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebioEA12x12UDP 3 } -- wtWebioEA12x12Binary Group -------------------------------- wtWebioEA12x12BinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebioEA12x12Binary 1 } -- Binary Interface Table wtWebioEA12x12BinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x12BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebioEA12x12Binary 2 } wtWebioEA12x12BinaryIfEntry OBJECT-TYPE SYNTAX WtWebioEA12x12BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebioEA12x12BinaryModeNo } ::= { wtWebioEA12x12BinaryIfTable 1 } WtWebioEA12x12BinaryIfEntry ::= SEQUENCE { wtWebioEA12x12BinaryModeNo INTEGER } wtWebioEA12x12BinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebioEA12x12BinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebioEA12x12BinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x12BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebioEA12x12Binary 3 } wtWebioEA12x12BinaryEntry OBJECT-TYPE SYNTAX WtWebioEA12x12BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebioEA12x12BinaryModeNo } ::= { wtWebioEA12x12BinaryTable 1 } WtWebioEA12x12BinaryEntry ::= SEQUENCE { wtWebioEA12x12BinaryOperationMode OCTET STRING, wtWebioEA12x12BinaryTcpServerLocalPort INTEGER, wtWebioEA12x12BinaryTcpServerInputTrigger OCTET STRING, wtWebioEA12x12BinaryTcpServerApplicationMode OCTET STRING, wtWebioEA12x12BinaryTcpClientLocalPort INTEGER, wtWebioEA12x12BinaryTcpClientServerPort INTEGER, wtWebioEA12x12BinaryTcpClientServerIpAddr OCTET STRING, wtWebioEA12x12BinaryTcpClientServerPassword OCTET STRING, wtWebioEA12x12BinaryTcpClientInactivity INTEGER, wtWebioEA12x12BinaryTcpClientInputTrigger OCTET STRING, wtWebioEA12x12BinaryTcpClientInterval INTEGER, wtWebioEA12x12BinaryTcpClientApplicationMode OCTET STRING, wtWebioEA12x12BinaryUdpPeerLocalPort INTEGER, wtWebioEA12x12BinaryUdpPeerRemotePort INTEGER, wtWebioEA12x12BinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebioEA12x12BinaryUdpPeerInputTrigger OCTET STRING, wtWebioEA12x12BinaryUdpPeerInterval INTEGER, wtWebioEA12x12BinaryUdpPeerApplicationMode OCTET STRING, wtWebioEA12x12BinaryConnectedPort INTEGER, wtWebioEA12x12BinaryConnectedIpAddr IpAddress, wtWebioEA12x12BinaryTcpServerClientHttpPort INTEGER, wtWebioEA12x12BinaryTcpClientServerHttpPort INTEGER } wtWebioEA12x12BinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebioEA12x12BinaryEntry 1 } wtWebioEA12x12BinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA12x12BinaryEntry 2 } wtWebioEA12x12BinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebioEA12x12BinaryEntry 3 } wtWebioEA12x12BinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA12x12BinaryEntry 4 } wtWebioEA12x12BinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA12x12BinaryEntry 5 } wtWebioEA12x12BinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebioEA12x12BinaryEntry 6 } wtWebioEA12x12BinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebioEA12x12BinaryEntry 7 } wtWebioEA12x12BinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebioEA12x12BinaryEntry 8 } wtWebioEA12x12BinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebioEA12x12BinaryEntry 9 } wtWebioEA12x12BinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebioEA12x12BinaryEntry 10 } wtWebioEA12x12BinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebioEA12x12BinaryEntry 11 } wtWebioEA12x12BinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA12x12BinaryEntry 12 } wtWebioEA12x12BinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA12x12BinaryEntry 13 } wtWebioEA12x12BinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebioEA12x12BinaryEntry 14 } wtWebioEA12x12BinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebioEA12x12BinaryEntry 15 } wtWebioEA12x12BinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebioEA12x12BinaryEntry 16 } wtWebioEA12x12BinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebioEA12x12BinaryEntry 17 } wtWebioEA12x12BinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA12x12BinaryEntry 18 } wtWebioEA12x12BinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebioEA12x12BinaryEntry 19 } wtWebioEA12x12BinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebioEA12x12BinaryEntry 20 } wtWebioEA12x12BinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebioEA12x12BinaryEntry 21 } wtWebioEA12x12BinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebioEA12x12BinaryEntry 22 } -- wtWebioEA12x12Syslog Group -------------------------------- wtWebioEA12x12SyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebioEA12x12Syslog 1 } wtWebioEA12x12SyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebioEA12x12Syslog 2 } wtWebioEA12x12SyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebioEA12x12Syslog 3 } wtWebioEA12x12SyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebioEA12x12Syslog 4 } -- wtWebioEA12x12FTP Group -------------------------------- wtWebioEA12x12FTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebioEA12x12FTP 1 } wtWebioEA12x12FTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioEA12x12FTP 2 } wtWebioEA12x12FTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebioEA12x12FTP 3 } wtWebioEA12x12FTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebioEA12x12FTP 4 } wtWebioEA12x12FTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebioEA12x12FTP 5 } wtWebioEA12x12FTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebioEA12x12FTP 6 } wtWebioEA12x12FTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebioEA12x12FTP 7 } -- wtWebioEA12x12OutputMode Group -------------------------------- -- OutputMode Table wtWebioEA12x12OutputModeTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x12OutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of output mode configurations dependent on the output indices." ::= { wtWebioEA12x12OutputMode 1 } wtWebioEA12x12OutputModeEntry OBJECT-TYPE SYNTAX WtWebioEA12x12OutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output mode configurations of the individual outputs." INDEX { wtWebioEA12x12OutputNo } ::= { wtWebioEA12x12OutputModeTable 1 } WtWebioEA12x12OutputModeEntry ::= SEQUENCE { wtWebioEA12x12OutputModeBit OCTET STRING } wtWebioEA12x12OutputModeBit OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebioEA12x12OutputModeEntry 1 } wtWebioEA12x12SafetyTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined." ::= { wtWebioEA12x12OutputMode 2 } wtWebioEA12x12LoadControlEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Here the function of automatic load control can be enabled. All output were tested in pairs (0-1, 2-3, 4-5, 6-7, 8-9, 10-11). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Load Control enable" ::= { wtWebioEA12x12OutputMode 3 } -- wtWebioEA12x12Alarm Group ---------------------------- wtWebioEA12x12AlarmCount OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebioEA12x12Alarm 1 } -- Alarm Interface Table wtWebioEA12x12AlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x12AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebioEA12x12Alarm 2 } wtWebioEA12x12AlarmIfEntry OBJECT-TYPE SYNTAX WtWebioEA12x12AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebioEA12x12AlarmNo } ::= { wtWebioEA12x12AlarmIfTable 1 } WtWebioEA12x12AlarmIfEntry ::= SEQUENCE { wtWebioEA12x12AlarmNo INTEGER } wtWebioEA12x12AlarmNo OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtWebioEA12x12AlarmIfEntry 1 } -- Alarm Table wtWebioEA12x12AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x12AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebioEA12x12Alarm 3 } wtWebioEA12x12AlarmEntry OBJECT-TYPE SYNTAX WtWebioEA12x12AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebioEA12x12AlarmNo } ::= { wtWebioEA12x12AlarmTable 1 } WtWebioEA12x12AlarmEntry ::= SEQUENCE { wtWebioEA12x12AlarmInputTrigger OCTET STRING, wtWebioEA12x12AlarmOutputTrigger OCTET STRING, wtWebioEA12x12AlarmSystemTrigger OCTET STRING, wtWebioEA12x12AlarmMaxCounterValue OCTET STRING, wtWebioEA12x12AlarmInterval OCTET STRING, wtWebioEA12x12AlarmEnable OCTET STRING, wtWebioEA12x12AlarmMailAddr OCTET STRING, wtWebioEA12x12AlarmMailSubject OCTET STRING, wtWebioEA12x12AlarmMailText OCTET STRING, wtWebioEA12x12AlarmSnmpManagerIP OCTET STRING, wtWebioEA12x12AlarmSnmpTrapText OCTET STRING, wtWebioEA12x12AlarmUdpIpAddr OCTET STRING, wtWebioEA12x12AlarmUdpPort INTEGER, wtWebioEA12x12AlarmUdpText OCTET STRING, wtWebioEA12x12AlarmTcpIpAddr OCTET STRING, wtWebioEA12x12AlarmTcpPort INTEGER, wtWebioEA12x12AlarmTcpText OCTET STRING, wtWebioEA12x12AlarmSyslogIpAddr OCTET STRING, wtWebioEA12x12AlarmSyslogPort INTEGER, wtWebioEA12x12AlarmSyslogText OCTET STRING, wtWebioEA12x12AlarmFtpDataPort OCTET STRING, wtWebioEA12x12AlarmFtpFileName OCTET STRING, wtWebioEA12x12AlarmFtpText OCTET STRING, wtWebioEA12x12AlarmFtpOption OCTET STRING, wtWebioEA12x12AlarmTimerCron OCTET STRING, wtWebioEA12x12AlarmMailReleaseSubject OCTET STRING, wtWebioEA12x12AlarmMailReleaseText OCTET STRING, wtWebioEA12x12AlarmSnmpTrapReleaseText OCTET STRING, wtWebioEA12x12AlarmUdpReleaseText OCTET STRING, wtWebioEA12x12AlarmTcpReleaseText OCTET STRING, wtWebioEA12x12AlarmSyslogReleaseText OCTET STRING, wtWebioEA12x12AlarmFtpReleaseText OCTET STRING } wtWebioEA12x12AlarmInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3, Bit 0-3: Mask for digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Mask for digital inputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7, Bit 0-3: Level of digital inputs 8-11 Bit 4-7: unused OCTET 8, Bit 0-7: Level of digital inputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unsused OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11 Bit 12-15 : unused OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7" ::= { wtWebioEA12x12AlarmEntry 1 } wtWebioEA12x12AlarmOutputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3, Bit 0-3: Mask for digital outputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Mask for digital outputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7, Bit 0-3: Level of digital outputs 8-11 Bit 4-7: unused OCTET 8, Bit 0-7: Level of digital outputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11 Bit 12-15 : unused OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7" ::= { wtWebioEA12x12AlarmEntry 2 } wtWebioEA12x12AlarmSystemTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control" ::= { wtWebioEA12x12AlarmEntry 3 } wtWebioEA12x12AlarmMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA12x12AlarmInputTrigger are not considered." ::= { wtWebioEA12x12AlarmEntry 4 } wtWebioEA12x12AlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebioEA12x12AlarmEntry 5 } wtWebioEA12x12AlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused" ::= { wtWebioEA12x12AlarmEntry 6 } wtWebioEA12x12AlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebioEA12x12AlarmEntry 7 } wtWebioEA12x12AlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA12x12AlarmEntry 8 } wtWebioEA12x12AlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA12x12AlarmEntry 9 } wtWebioEA12x12AlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebioEA12x12AlarmEntry 10 } wtWebioEA12x12AlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA12x12AlarmEntry 11 } wtWebioEA12x12AlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA12x12AlarmEntry 12 } wtWebioEA12x12AlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA12x12AlarmEntry 13 } wtWebioEA12x12AlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA12x12AlarmEntry 14 } wtWebioEA12x12AlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA12x12AlarmEntry 15 } wtWebioEA12x12AlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA12x12AlarmEntry 16 } wtWebioEA12x12AlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA12x12AlarmEntry 17 } wtWebioEA12x12AlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA12x12AlarmEntry 18 } wtWebioEA12x12AlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA12x12AlarmEntry 19 } wtWebioEA12x12AlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA12x12AlarmEntry 20 } wtWebioEA12x12AlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebioEA12x12AlarmEntry 21 } wtWebioEA12x12AlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebioEA12x12AlarmEntry 22 } wtWebioEA12x12AlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA12x12AlarmEntry 23 } wtWebioEA12x12AlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebioEA12x12AlarmEntry 24 } wtWebioEA12x12AlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebioEA12x12AlarmEntry 25 } wtWebioEA12x12AlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA12x12AlarmEntry 26 } wtWebioEA12x12AlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA12x12AlarmEntry 27 } wtWebioEA12x12AlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA12x12AlarmEntry 28 } wtWebioEA12x12AlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA12x12AlarmEntry 29 } wtWebioEA12x12AlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA12x12AlarmEntry 30 } wtWebioEA12x12AlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA12x12AlarmEntry 31 } wtWebioEA12x12AlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA12x12AlarmEntry 32 } -- wtWebioEA12x12LoadControl ---------------------------- wtWebioEA12x12LoadControlView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Here the result of automatic load control can be read. All output were tested in pairs (0-1, 2-3, 4-5, 6-7, 8-9, 10-11). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: Bit 4-7: unused Bit 0-3: outputs 8-11 Octet 4: Bit 0-7: outputs 0-7." ::= { wtWebioEA12x12Alarm 4 } wtWebioEA12x12LCShutDownView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Here the result of the automatic load control shut down can be read. All outputs remain switched of, until a zero is written into this variable. But previously all loads should be inspected. High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason. If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair. All controlled output could be identified reading the variable wtWebioEA12x12LoadControlEnable. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: Bit 4-7: unused Bit 0-3: outputs 8-11 Octet 4: Bit 0-7: outputs 0-7." ::= { wtWebioEA12x12Alarm 5 } -- wtWebioEA12x12Ports Group ---------------------------- -- Input Port Table wtWebioEA12x12InputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x12InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebioEA12x12Ports 1 } wtWebioEA12x12InputPortEntry OBJECT-TYPE SYNTAX WtWebioEA12x12InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebioEA12x12InputNo } ::= { wtWebioEA12x12InputPortTable 1 } WtWebioEA12x12InputPortEntry ::= SEQUENCE { wtWebioEA12x12PortInputName OCTET STRING, wtWebioEA12x12PortInputText OCTET STRING, wtWebioEA12x12PortInputMode OCTET STRING, wtWebioEA12x12PortInputFilter INTEGER, wtWebioEA12x12PortInputBicountPulsePolarity OCTET STRING, wtWebioEA12x12PortInputBicountInactivTimeout INTEGER } wtWebioEA12x12PortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebioEA12x12InputPortEntry 1 } wtWebioEA12x12PortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebioEA12x12InputPortEntry 2 } wtWebioEA12x12PortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an input. Bit 0 corresponds to the LSB. Selection for input 0-3: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 3-7: unused Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable Selection for inputs 4-11: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on read Bit 0 : Change detection enable (default)" ::= { wtWebioEA12x12InputPortEntry 3 } wtWebioEA12x12PortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebioEA12x12InputPortEntry 4 } wtWebioEA12x12PortInputBicountPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA12x12InputPortEntry 5 } wtWebioEA12x12PortInputBicountInactivTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored." ::= { wtWebioEA12x12InputPortEntry 6 } -- Output Port Table wtWebioEA12x12OutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x12OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtWebioEA12x12Ports 2 } wtWebioEA12x12OutputPortEntry OBJECT-TYPE SYNTAX WtWebioEA12x12OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtWebioEA12x12OutputNo } ::= { wtWebioEA12x12OutputPortTable 1 } WtWebioEA12x12OutputPortEntry ::= SEQUENCE { wtWebioEA12x12PortOutputName OCTET STRING, wtWebioEA12x12PortOutputText OCTET STRING, wtWebioEA12x12PortOutputGroupMode OCTET STRING, wtWebioEA12x12PortOutputSafetyState OCTET STRING, wtWebioEA12x12PortLogicInputMask OCTET STRING, wtWebioEA12x12PortLogicInputInverter OCTET STRING, wtWebioEA12x12PortLogicFunction OCTET STRING, wtWebioEA12x12PortLogicOutputInverter OCTET STRING, wtWebioEA12x12PortPulseDuration INTEGER, wtWebioEA12x12PortPulsePolarity OCTET STRING } wtWebioEA12x12PortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtWebioEA12x12OutputPortEntry 1 } wtWebioEA12x12PortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtWebioEA12x12OutputPortEntry 2 } wtWebioEA12x12PortOutputGroupMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one output bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for outputs 0-3: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 0,1,2,3 disconnected (default) Bit 1 : outputs 0+1, 2+3 connected Bit 2 : outputs 0+1+2+3 connected Bit 3-7 : unused Selection for outputs 4-7: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 4, 5, 6, 7 disconnected (default) Bit 1 : outputs 4+5, 6+7 connected Bit 2 : outputs 4+5+6+7 connected Bit 3-7 : unused Selection for outputs 8-11: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 8, 9, 10, 11 disconnected (default) Bit 1 : outputs 8+9, 10+11 connected Bit 2 : outputs 8+9+10+11 connected Bit 3-7 : unused" ::= { wtWebioEA12x12OutputPortEntry 3 } wtWebioEA12x12PortOutputSafetyState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 Bit 4-7: unused Bit 0-3: Mask for digital output 8-11 OCTET 4, Bit 0-7: Mask for digital output 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 Bit 4-7: unused Bit 0-3: Level of digital output 8-11 OCTET 8 Bit 0-7 : Level of digital output 0-7" ::= { wtWebioEA12x12OutputPortEntry 4 } wtWebioEA12x12PortLogicInputMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA12x12PortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA12x12PortLogicInputInverter) 3. Logical combination (wtWebioEA12x12PortLogicFunction) 4. Inverting the result if necessary (wtWebioEA12x12PortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : inputs 8-11 Bit 4-7 : unused OCTET 4: Bit 0-7 : inputs 0-7" ::= { wtWebioEA12x12OutputPortEntry 5 } wtWebioEA12x12PortLogicInputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : inputs 8-11 Bit 4-7 : unused OCTET 4: Bit 0-7 : inputs 0-7" ::= { wtWebioEA12x12OutputPortEntry 6 } wtWebioEA12x12PortLogicFunction OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused" ::= { wtWebioEA12x12OutputPortEntry 7 } wtWebioEA12x12PortLogicOutputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused" ::= { wtWebioEA12x12OutputPortEntry 8 } wtWebioEA12x12PortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtWebioEA12x12OutputPortEntry 9 } wtWebioEA12x12PortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtWebioEA12x12PortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA12x12OutputPortEntry 10 } -- wtWebioEA12x12Manufact Group ---------------------------- wtWebioEA12x12MfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebioEA12x12Manufact 1 } wtWebioEA12x12MfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebioEA12x12Manufact 2 } wtWebioEA12x12MfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebioEA12x12Manufact 3 } wtWebioEA12x12MfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebioEA12x12Manufact 4 } wtWebioEA12x12MfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebioEA12x12Manufact 5 } -- wtWebioEA12x12Diag Group ---------------------------- wtWebioEA12x12DiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebioEA12x12Diag 1 } wtWebioEA12x12DiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebioEA12x12Diag 2 } wtWebioEA12x12DiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebioEA12x12DiagErrorMessage. Errors are numbered from 1 to wtWebioEA12x12DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA12x12DiagErrorMessage." ::= { wtWebioEA12x12Diag 3 } wtWebioEA12x12DiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebioEA12x12DiagErrorIndex as an index, the appropriate message is available." ::= { wtWebioEA12x12Diag 4 } wtWebioEA12x12DiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebioEA12x12Diag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebioEA12x12Alert1 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtWebioEA12x12Alert2 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtWebioEA12x12Alert3 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtWebioEA12x12Alert4 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtWebioEA12x12Alert5 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtWebioEA12x12Alert6 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtWebioEA12x12Alert7 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtWebioEA12x12Alert8 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtWebioEA12x12Alert9 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtWebioEA12x12Alert10 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtWebioEA12x12Alert11 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtWebioEA12x12Alert12 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtWebioEA12x12Alert13 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebioEA12x12Alert14 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebioEA12x12Alert15 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebioEA12x12Alert16 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebioEA12x12Alert17 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebioEA12x12Alert18 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebioEA12x12Alert19 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebioEA12x12Alert20 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebioEA12x12Alert21 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtWebioEA12x12Alert22 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtWebioEA12x12Alert23 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebioEA12x12Alert24 TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebioEA12x12AlertDiag TRAP-TYPE ENTERPRISE wtWebioEA12x12 VARIABLES { wtWebioEA12x12DiagErrorIndex, wtWebioEA12x12DiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebioEA24oemInOut Group ------------------------ wtWebioEA24oemInputs OBJECT-TYPE SYNTAX INTEGER (1..24) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent inputs." ::= { wtWebioEA24oemInOut 1 } wtWebioEA24oemOutputs OBJECT-TYPE SYNTAX INTEGER (1..24) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent outputs." ::= { wtWebioEA24oemInOut 2 } -- Input Interface Table wtWebioEA24oemInputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA24oemInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebioEA24oemInOut 3 } wtWebioEA24oemInputEntry OBJECT-TYPE SYNTAX WtWebioEA24oemInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the inputs." INDEX { wtWebioEA24oemInputNo } ::= { wtWebioEA24oemInputTable 1 } WtWebioEA24oemInputEntry ::= SEQUENCE { wtWebioEA24oemInputNo INTEGER, wtWebioEA24oemInputCounter INTEGER, wtWebioEA24oemInputCounterClear INTEGER, wtWebioEA24oemInputState INTEGER } wtWebioEA24oemInputNo OBJECT-TYPE SYNTAX INTEGER (1..24) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebioEA24oemInputEntry 1 } wtWebioEA24oemInputCounter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebioEA24oemInputEntry 2 } wtWebioEA24oemInputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter. After reading this counter will be cleared." ::= { wtWebioEA24oemInputEntry 3 } wtWebioEA24oemInputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of a single input bit, 0-OFF, 1-ON." ::= { wtWebioEA24oemInputEntry 4 } wtWebioEA24oemInputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: Bit 0-7 : inputs 16 - 23 OCTET 3: Bit 0-7 : inputs 8 - 15 OCTET 4: Bit 0-7 : inputs 0 - 7" ::= { wtWebioEA24oemInOut 4 } -- Output Interface Table wtWebioEA24oemOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA24oemOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtWebioEA24oemInOut 5 } wtWebioEA24oemOutputEntry OBJECT-TYPE SYNTAX WtWebioEA24oemOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the outputs." INDEX { wtWebioEA24oemOutputNo } ::= { wtWebioEA24oemOutputTable 1 } WtWebioEA24oemOutputEntry ::= SEQUENCE { wtWebioEA24oemOutputNo INTEGER, wtWebioEA24oemOutputState INTEGER } wtWebioEA24oemOutputNo OBJECT-TYPE SYNTAX INTEGER (1..24) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the outputs." ::= { wtWebioEA24oemOutputEntry 1 } wtWebioEA24oemOutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of a single output bit, 0-OFF, 1-ON." ::= { wtWebioEA24oemOutputEntry 2 } wtWebioEA24oemOutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: Bit 0-7: Digital outputs 16-23 OCTET 3, Bit 0-7: Digital outputs 8-15 OCTET 4, Bit 0-7: Digital outputs 0-7" ::= { wtWebioEA24oemInOut 6 } wtWebioEA24oemSetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1: unused OCTET 2: Bit 0-7: Mask for digital outputs 16-23 OCTET 3, Bit 0-7: Mask for digital outputs 8-15 OCTET 4, Bit 0-7: Mask for digital outputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5: unused OCTET 6: Bit 0-7: Level of digital outputs 16-23 OCTET 7, Bit 0-7: Level of digital outputs 8-15 OCTET 8, Bit 0-7: Level of digital outputs 0-7" ::= { wtWebioEA24oemInOut 7 } -- wtWebioEA24oemSessCntrl Group -------------------------------- wtWebioEA24oemSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebioEA24oemSessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebioEA24oemSessCntrl 1 } wtWebioEA24oemSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebioEA24oemSessCntrl 2 } wtWebioEA24oemSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebioEA24oemSessCntrl 3 } wtWebioEA24oemSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebioEA24oemSessCntrl 4 } wtWebioEA24oemSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebioEA24oemSessCntrl 5 } -- wtWebioEA24oemText Group ------------------------ wtWebioEA24oemDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebioEA24oemText 1 } wtWebioEA24oemDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebioEA24oemText 2 } wtWebioEA24oemDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebioEA24oemText 3 } wtWebioEA24oemDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebioEA24oemText 4 } -- wtWebioEA24oemTimeZone Group ---------------------------- wtWebioEA24oemTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebioEA24oemTimeZone 1 } wtWebioEA24oemTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebioEA24oemTimeZone 2 } wtWebioEA24oemTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebioEA24oemTimeZone 3 } wtWebioEA24oemStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebioEA24oemTimeZone 4 } wtWebioEA24oemStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebioEA24oemTimeZone 5 } wtWebioEA24oemStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebioEA24oemTimeZone 6 } wtWebioEA24oemStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA24oemStartMonth-January(1), wtWebioEA24oemStartMonth-February(2), wtWebioEA24oemStartMonth-March(3), wtWebioEA24oemStartMonth-April(4), wtWebioEA24oemStartMonth-May(5), wtWebioEA24oemStartMonth-June(6), wtWebioEA24oemStartMonth-July(7), wtWebioEA24oemStartMonth-August(8), wtWebioEA24oemStartMonth-September(9), wtWebioEA24oemStartMonth-October(10), wtWebioEA24oemStartMonth-November(11), wtWebioEA24oemStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebioEA24oemTimeZone 7 } wtWebioEA24oemStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA24oemStartMode-first(1), wtWebioEA24oemStartMode-second(2), wtWebioEA24oemStartMode-third(3), wtWebioEA24oemStartMode-fourth(4), wtWebioEA24oemStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebioEA24oemTimeZone 8 } wtWebioEA24oemStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA24oemStartWday-Sunday(1), wtWebioEA24oemStartWday-Monday(2), wtWebioEA24oemStartWday-Tuesday(3), wtWebioEA24oemStartWday-Thursday(4), wtWebioEA24oemStartWday-Wednesday(5), wtWebioEA24oemStartWday-Friday(6), wtWebioEA24oemStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebioEA24oemTimeZone 9 } wtWebioEA24oemStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA24oemTimeZone 10 } wtWebioEA24oemStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA24oemTimeZone 11 } wtWebioEA24oemStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA24oemStopMonth-January(1), wtWebioEA24oemStopMonth-February(2), wtWebioEA24oemStopMonth-March(3), wtWebioEA24oemStopMonth-April(4), wtWebioEA24oemStopMonth-May(5), wtWebioEA24oemStopMonth-June(6), wtWebioEA24oemStopMonth-July(7), wtWebioEA24oemStopMonth-August(8), wtWebioEA24oemStopMonth-September(9), wtWebioEA24oemStopMonth-October(10), wtWebioEA24oemStopMonth-November(11), wtWebioEA24oemStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebioEA24oemTimeZone 12 } wtWebioEA24oemStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA24oemStopMode-first(1), wtWebioEA24oemStopMode-second(2), wtWebioEA24oemStopMode-third(3), wtWebioEA24oemStopMode-fourth(4), wtWebioEA24oemStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebioEA24oemTimeZone 13 } wtWebioEA24oemStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA24oemStopWday-Sunday(1), wtWebioEA24oemStopWday-Monday(2), wtWebioEA24oemStopWday-Tuesday(3), wtWebioEA24oemStopWday-Thursday(4), wtWebioEA24oemStopWday-Wednesday(5), wtWebioEA24oemStopWday-Friday(6), wtWebioEA24oemStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebioEA24oemTimeZone 14 } wtWebioEA24oemStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA24oemTimeZone 15 } wtWebioEA24oemStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA24oemTimeZone 16 } -- wtWebioEA24oemTimeServer Group ---------------------------- wtWebioEA24oemTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebioEA24oemTimeServer 1 } wtWebioEA24oemTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebioEA24oemTimeServer 2 } wtWebioEA24oemTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebioEA24oemTimeServer 3 } wtWebioEA24oemTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebioEA24oemTimeServer 4 } -- wtWebioEA24oemDeviceClock Group -------------------------------- wtWebioEA24oemClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebioEA24oemDeviceClock 1 } wtWebioEA24oemClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebioEA24oemDeviceClock 2 } wtWebioEA24oemClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebioEA24oemDeviceClock 3 } wtWebioEA24oemClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA24oemClockMonth-January(1), wtWebioEA24oemClockMonth-February(2), wtWebioEA24oemClockMonth-March(3), wtWebioEA24oemClockMonth-April(4), wtWebioEA24oemClockMonth-May(5), wtWebioEA24oemClockMonth-June(6), wtWebioEA24oemClockMonth-July(7), wtWebioEA24oemClockMonth-August(8), wtWebioEA24oemClockMonth-September(9), wtWebioEA24oemClockMonth-October(10), wtWebioEA24oemClockMonth-November(11), wtWebioEA24oemClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebioEA24oemDeviceClock 4 } wtWebioEA24oemClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebioEA24oemDeviceClock 5 } -- wtWebioEA24oemNetwork Group -------------------------------- wtWebioEA24oemIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebioEA24oemNetwork 1 } wtWebioEA24oemSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebioEA24oemNetwork 2 } wtWebioEA24oemGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebioEA24oemNetwork 3 } wtWebioEA24oemDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebioEA24oemNetwork 4 } wtWebioEA24oemDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebioEA24oemNetwork 5 } wtWebioEA24oemAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebioEA24oemNetwork 6 } -- wtWebioEA24oemHTTP Group -------------------------------- wtWebioEA24oemStartup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebioEA24oemHTTP 1 } wtWebioEA24oemGetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebioEA24oemHTTP 2 } wtWebioEA24oemHttpInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: Bit 0-7 : inputs 16 - 23 OCTET 3: Bit 0-7 : inputs 8 - 15 OCTET 4: Bit 0-7 : inputs 0 - 7" ::= { wtWebioEA24oemHTTP 3 } wtWebioEA24oemHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebioEA24oemHTTP 4 } -- wtWebioEA24oemMail Group -------------------------------- wtWebioEA24oemMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebioEA24oemMail 1 } wtWebioEA24oemMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebioEA24oemMail 2 } wtWebioEA24oemMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebioEA24oemMail 3 } wtWebioEA24oemMailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebioEA24oemMail 4 } wtWebioEA24oemMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebioEA24oemMail 5 } wtWebioEA24oemMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebioEA24oemMail 6 } wtWebioEA24oemMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebioEA24oemMail 7 } wtWebioEA24oemMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebioEA24oemMail 8 } -- wtWebioEA24oemSnmp Group -------------------------------- wtWebioEA24oemSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebioEA24oemSNMP 1 } wtWebioEA24oemSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebioEA24oemSNMP 2 } wtWebioEA24oemSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebioEA24oemSNMP 3 } wtWebioEA24oemSnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebioEA24oemSNMP 4 } wtWebioEA24oemSnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused" ::= { wtWebioEA24oemSNMP 5 } -- wtWebioEA24oemUdp Group -------------------------------- wtWebioEA24oemUdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebioEA24oemUDP 1 } wtWebioEA24oemUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebioEA24oemUDP 2 } wtWebioEA24oemUdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebioEA24oemUDP 3 } -- wtWebioEA24oemBinary Group -------------------------------- wtWebioEA24oemBinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebioEA24oemBinary 1 } -- Binary Interface Table wtWebioEA24oemBinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA24oemBinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebioEA24oemBinary 2 } wtWebioEA24oemBinaryIfEntry OBJECT-TYPE SYNTAX WtWebioEA24oemBinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebioEA24oemBinaryModeNo } ::= { wtWebioEA24oemBinaryIfTable 1 } WtWebioEA24oemBinaryIfEntry ::= SEQUENCE { wtWebioEA24oemBinaryModeNo INTEGER } wtWebioEA24oemBinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebioEA24oemBinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebioEA24oemBinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA24oemBinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebioEA24oemBinary 3 } wtWebioEA24oemBinaryEntry OBJECT-TYPE SYNTAX WtWebioEA24oemBinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebioEA24oemBinaryModeNo } ::= { wtWebioEA24oemBinaryTable 1 } WtWebioEA24oemBinaryEntry ::= SEQUENCE { wtWebioEA24oemBinaryOperationMode OCTET STRING, wtWebioEA24oemBinaryTcpServerLocalPort INTEGER, wtWebioEA24oemBinaryTcpServerInputTrigger OCTET STRING, wtWebioEA24oemBinaryTcpServerApplicationMode OCTET STRING, wtWebioEA24oemBinaryTcpClientLocalPort INTEGER, wtWebioEA24oemBinaryTcpClientServerPort INTEGER, wtWebioEA24oemBinaryTcpClientServerIpAddr OCTET STRING, wtWebioEA24oemBinaryTcpClientServerPassword OCTET STRING, wtWebioEA24oemBinaryTcpClientInactivity INTEGER, wtWebioEA24oemBinaryTcpClientInputTrigger OCTET STRING, wtWebioEA24oemBinaryTcpClientInterval INTEGER, wtWebioEA24oemBinaryTcpClientApplicationMode OCTET STRING, wtWebioEA24oemBinaryUdpPeerLocalPort INTEGER, wtWebioEA24oemBinaryUdpPeerRemotePort INTEGER, wtWebioEA24oemBinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebioEA24oemBinaryUdpPeerInputTrigger OCTET STRING, wtWebioEA24oemBinaryUdpPeerInterval INTEGER, wtWebioEA24oemBinaryUdpPeerApplicationMode OCTET STRING, wtWebioEA24oemBinaryConnectedPort INTEGER, wtWebioEA24oemBinaryConnectedIpAddr IpAddress, wtWebioEA24oemBinaryTcpServerClientHttpPort INTEGER, wtWebioEA24oemBinaryTcpClientServerHttpPort INTEGER } wtWebioEA24oemBinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebioEA24oemBinaryEntry 1 } wtWebioEA24oemBinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA24oemBinaryEntry 2 } wtWebioEA24oemBinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: Bit 0-7 : inputs 16 - 23 OCTET 3: Bit 0-7 : inputs 8 - 15 OCTET 4: Bit 0-7 : inputs 0 - 7" ::= { wtWebioEA24oemBinaryEntry 3 } wtWebioEA24oemBinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA24oemBinaryEntry 4 } wtWebioEA24oemBinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA24oemBinaryEntry 5 } wtWebioEA24oemBinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebioEA24oemBinaryEntry 6 } wtWebioEA24oemBinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebioEA24oemBinaryEntry 7 } wtWebioEA24oemBinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebioEA24oemBinaryEntry 8 } wtWebioEA24oemBinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebioEA24oemBinaryEntry 9 } wtWebioEA24oemBinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: Bit 0-7 : inputs 16 - 23 OCTET 3: Bit 0-7 : inputs 8 - 15 OCTET 4: Bit 0-7 : inputs 0 - 7" ::= { wtWebioEA24oemBinaryEntry 10 } wtWebioEA24oemBinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebioEA24oemBinaryEntry 11 } wtWebioEA24oemBinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA24oemBinaryEntry 12 } wtWebioEA24oemBinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA24oemBinaryEntry 13 } wtWebioEA24oemBinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebioEA24oemBinaryEntry 14 } wtWebioEA24oemBinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebioEA24oemBinaryEntry 15 } wtWebioEA24oemBinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: Bit 0-7 : inputs 16 - 23 OCTET 3: Bit 0-7 : inputs 8 - 15 OCTET 4: Bit 0-7 : inputs 0 - 7" ::= { wtWebioEA24oemBinaryEntry 16 } wtWebioEA24oemBinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebioEA24oemBinaryEntry 17 } wtWebioEA24oemBinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA24oemBinaryEntry 18 } wtWebioEA24oemBinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebioEA24oemBinaryEntry 19 } wtWebioEA24oemBinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebioEA24oemBinaryEntry 20 } wtWebioEA24oemBinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebioEA24oemBinaryEntry 21 } wtWebioEA24oemBinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebioEA24oemBinaryEntry 22 } -- wtWebioEA24oemSyslog Group -------------------------------- wtWebioEA24oemSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebioEA24oemSyslog 1 } wtWebioEA24oemSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebioEA24oemSyslog 2 } wtWebioEA24oemSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebioEA24oemSyslog 3 } wtWebioEA24oemSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebioEA24oemSyslog 4 } -- wtWebioEA24oemFTP Group -------------------------------- wtWebioEA24oemFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebioEA24oemFTP 1 } wtWebioEA24oemFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioEA24oemFTP 2 } wtWebioEA24oemFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebioEA24oemFTP 3 } wtWebioEA24oemFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebioEA24oemFTP 4 } wtWebioEA24oemFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebioEA24oemFTP 5 } wtWebioEA24oemFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebioEA24oemFTP 6 } wtWebioEA24oemFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebioEA24oemFTP 7 } -- wtWebioEA24oemOutputMode Group -------------------------------- -- OutputMode Table wtWebioEA24oemOutputModeTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA24oemOutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of output mode configurations dependent on the output indices." ::= { wtWebioEA24oemOutputMode 1 } wtWebioEA24oemOutputModeEntry OBJECT-TYPE SYNTAX WtWebioEA24oemOutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output mode configurations of the individual outputs." INDEX { wtWebioEA24oemOutputNo } ::= { wtWebioEA24oemOutputModeTable 1 } WtWebioEA24oemOutputModeEntry ::= SEQUENCE { wtWebioEA24oemOutputModeBit OCTET STRING } wtWebioEA24oemOutputModeBit OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebioEA24oemOutputModeEntry 1 } wtWebioEA24oemSafetyTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined." ::= { wtWebioEA24oemOutputMode 2 } wtWebioEA24oemLoadControlEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Here the function of automatic load control can be enabled. All output were tested in pairs (0-1, 2-3, 4-5, 6-7, 8-9, 10-11). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Load Control enable" ::= { wtWebioEA24oemOutputMode 3 } -- wtWebioEA24oemAlarm Group ---------------------------- wtWebioEA24oemAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebioEA24oemAlarm 1 } -- Alarm Interface Table wtWebioEA24oemAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA24oemAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebioEA24oemAlarm 2 } wtWebioEA24oemAlarmIfEntry OBJECT-TYPE SYNTAX WtWebioEA24oemAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebioEA24oemAlarmNo } ::= { wtWebioEA24oemAlarmIfTable 1 } WtWebioEA24oemAlarmIfEntry ::= SEQUENCE { wtWebioEA24oemAlarmNo INTEGER } wtWebioEA24oemAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtWebioEA24oemAlarmIfEntry 1 } -- Alarm Table wtWebioEA24oemAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA24oemAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebioEA24oemAlarm 3 } wtWebioEA24oemAlarmEntry OBJECT-TYPE SYNTAX WtWebioEA24oemAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebioEA24oemAlarmNo } ::= { wtWebioEA24oemAlarmTable 1 } WtWebioEA24oemAlarmEntry ::= SEQUENCE { wtWebioEA24oemAlarmInputTrigger OCTET STRING, wtWebioEA24oemAlarmOutputTrigger OCTET STRING, wtWebioEA24oemAlarmSystemTrigger OCTET STRING, wtWebioEA24oemAlarmMaxCounterValue OCTET STRING, wtWebioEA24oemAlarmInterval OCTET STRING, wtWebioEA24oemAlarmEnable OCTET STRING, wtWebioEA24oemAlarmMailAddr OCTET STRING, wtWebioEA24oemAlarmMailSubject OCTET STRING, wtWebioEA24oemAlarmMailText OCTET STRING, wtWebioEA24oemAlarmSnmpManagerIP OCTET STRING, wtWebioEA24oemAlarmSnmpTrapText OCTET STRING, wtWebioEA24oemAlarmUdpIpAddr OCTET STRING, wtWebioEA24oemAlarmUdpPort INTEGER, wtWebioEA24oemAlarmUdpText OCTET STRING, wtWebioEA24oemAlarmTcpIpAddr OCTET STRING, wtWebioEA24oemAlarmTcpPort INTEGER, wtWebioEA24oemAlarmTcpText OCTET STRING, wtWebioEA24oemAlarmSyslogIpAddr OCTET STRING, wtWebioEA24oemAlarmSyslogPort INTEGER, wtWebioEA24oemAlarmSyslogText OCTET STRING, wtWebioEA24oemAlarmFtpDataPort OCTET STRING, wtWebioEA24oemAlarmFtpFileName OCTET STRING, wtWebioEA24oemAlarmFtpText OCTET STRING, wtWebioEA24oemAlarmFtpOption OCTET STRING, wtWebioEA24oemAlarmTimerCron OCTET STRING } wtWebioEA24oemAlarmInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2: Bit 0-7: Mask for digital inputs 16-23 OCTET 3, Bit 0-7: Mask for digital inputs 8-15 OCTET 4, Bit 0-7: Mask for digital inputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6: Bit 0-7: Level of digital inputs 16-23 OCTET 7, Bit 0-7: Level of digital inputs 8-15 OCTET 8, Bit 0-7: Level of digital inputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10, Bit 0-7: ANY bits of digital inputs 16-23 OCTET 11, Bit 0-7: ANY bits of digital inputs 8-15 OCTET 12, Bit 0-7: ANY bits of digital inputs 0-7" ::= { wtWebioEA24oemAlarmEntry 1 } wtWebioEA24oemAlarmOutputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2: Bit 0-7: Mask for digital outputs 16-23 OCTET 3, Bit 0-7: Mask for digital outputs 8-15 OCTET 4, Bit 0-7: Mask for digital outputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6: Bit 0-7: Level of digital outputs 16-23 OCTET 7, Bit 0-7: Level of digital outputs 8-15 OCTET 8, Bit 0-7: Level of digital outputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10, Bit 0-7: ANY bits of digital outputs 16-23 OCTET 11, Bit 0-7: ANY bits of digital outputs 8-15 OCTET 12, Bit 0-7: ANY bits of digital outputs 0-7" ::= { wtWebioEA24oemAlarmEntry 2 } wtWebioEA24oemAlarmSystemTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control" ::= { wtWebioEA24oemAlarmEntry 3 } wtWebioEA24oemAlarmMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA24oemAlarmInputTrigger are not considered." ::= { wtWebioEA24oemAlarmEntry 4 } wtWebioEA24oemAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebioEA24oemAlarmEntry 5 } wtWebioEA24oemAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4-7: unused" ::= { wtWebioEA24oemAlarmEntry 6 } wtWebioEA24oemAlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebioEA24oemAlarmEntry 7 } wtWebioEA24oemAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA24oemAlarmEntry 8 } wtWebioEA24oemAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA24oemAlarmEntry 9 } wtWebioEA24oemAlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebioEA24oemAlarmEntry 10 } wtWebioEA24oemAlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA24oemAlarmEntry 11 } wtWebioEA24oemAlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA24oemAlarmEntry 12 } wtWebioEA24oemAlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA24oemAlarmEntry 13 } wtWebioEA24oemAlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA24oemAlarmEntry 14 } wtWebioEA24oemAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA24oemAlarmEntry 15 } wtWebioEA24oemAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA24oemAlarmEntry 16 } wtWebioEA24oemAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA24oemAlarmEntry 17 } wtWebioEA24oemAlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA24oemAlarmEntry 18 } wtWebioEA24oemAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA24oemAlarmEntry 19 } wtWebioEA24oemAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA24oemAlarmEntry 20 } wtWebioEA24oemAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebioEA24oemAlarmEntry 21 } wtWebioEA24oemAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebioEA24oemAlarmEntry 22 } wtWebioEA24oemAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA24oemAlarmEntry 23 } wtWebioEA24oemAlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebioEA24oemAlarmEntry 24 } wtWebioEA24oemAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebioEA24oemAlarmEntry 25 } -- wtWebioEA24oemLoadControl ---------------------------- wtWebioEA24oemLoadControlView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Here the result of automatic load control can be read. All output were tested in pairs (0-1, 2-3, 4-5, 6-7, 8-9, 10-11). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused OCTET 2: Bit 0-7 : outputs 16 - 23 OCTET 3: Bit 0-7 : outputs 8 - 15 OCTET 4: Bit 0-7 : outputs 0 - 7" ::= { wtWebioEA24oemAlarm 4 } wtWebioEA24oemLCShutDownView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Here the result of the automatic load control shut down can be read. All outputs remain switched of, until a zero is written into this variable. But previously all loads should be inspected. High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason. If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair. All controlled output could be identified reading the variable wtWebioEA24oemLoadControlEnable. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused OCTET 2: Bit 0-7 : outputs 16 - 23 OCTET 3: Bit 0-7 : outputs 8 - 15 OCTET 4: Bit 0-7 : outputs 0 - 7" ::= { wtWebioEA24oemAlarm 5 } -- wtWebioEA24oemPorts Group ---------------------------- -- Input Port Table wtWebioEA24oemInputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA24oemInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebioEA24oemPorts 1 } wtWebioEA24oemInputPortEntry OBJECT-TYPE SYNTAX WtWebioEA24oemInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebioEA24oemInputNo } ::= { wtWebioEA24oemInputPortTable 1 } WtWebioEA24oemInputPortEntry ::= SEQUENCE { wtWebioEA24oemPortInputName OCTET STRING, wtWebioEA24oemPortInputText OCTET STRING, wtWebioEA24oemPortInputMode OCTET STRING, wtWebioEA24oemPortInputFilter INTEGER } wtWebioEA24oemPortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebioEA24oemInputPortEntry 1 } wtWebioEA24oemPortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebioEA24oemInputPortEntry 2 } wtWebioEA24oemPortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an input. Bit 0 corresponds to the LSB. Selection for input 0-3: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable Selection for inputs 4-11: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on read Bit 0 : Change detection enable (default)" ::= { wtWebioEA24oemInputPortEntry 3 } wtWebioEA24oemPortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebioEA24oemInputPortEntry 4 } -- Output Port Table wtWebioEA24oemOutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA24oemOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtWebioEA24oemPorts 2 } wtWebioEA24oemOutputPortEntry OBJECT-TYPE SYNTAX WtWebioEA24oemOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtWebioEA24oemOutputNo } ::= { wtWebioEA24oemOutputPortTable 1 } WtWebioEA24oemOutputPortEntry ::= SEQUENCE { wtWebioEA24oemPortOutputName OCTET STRING, wtWebioEA24oemPortOutputText OCTET STRING, wtWebioEA24oemPortOutputGroupMode OCTET STRING, wtWebioEA24oemPortOutputSafetyState OCTET STRING, wtWebioEA24oemPortLogicInputMask OCTET STRING, wtWebioEA24oemPortLogicInputInverter OCTET STRING, wtWebioEA24oemPortLogicFunction OCTET STRING, wtWebioEA24oemPortLogicOutputInverter OCTET STRING, wtWebioEA24oemPortPulseDuration INTEGER, wtWebioEA24oemPortPulsePolarity OCTET STRING } wtWebioEA24oemPortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtWebioEA24oemOutputPortEntry 1 } wtWebioEA24oemPortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtWebioEA24oemOutputPortEntry 2 } wtWebioEA24oemPortOutputGroupMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one output bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for outputs 0-3: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 0,1,2,3 disconnected (default) Bit 1 : outputs 0+1, 2+3 connected Bit 2 : outputs 0+1+2+3 connected Bit 3-7 : unused Selection for outputs 4-7: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 4, 5, 6, 7 disconnected (default) Bit 1 : outputs 4+5, 6+7 connected Bit 2 : outputs 4+5+6+7 connected Bit 3-7 : unused Selection for outputs 8-11: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 8, 9, 10, 11 disconnected (default) Bit 1 : outputs 8+9, 10+11 connected Bit 2 : outputs 8+9+10+11 connected Bit 3-7 : unused Selection for outputs 12-15: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : outputs 12,13,14,15 disconnected (default) Bit 1 : outputs 12+13,14+15 connected Bit 2 : outputs 12+13+14+15 connected Bit 3-7 : unused Selection for outputs 16-19: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : outputs 16,17,18,19 disconnected (default) Bit 1 : outputs 16+17,18+19 connected Bit 2 : outputs 16+17+18+19 connected Bit 3-7 : unused Selection for outputs 20-23: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : outputs 20,21,22,23 disconnected (default) Bit 1 : outputs 20+21,22+23 connected Bit 2 : outputs 20+21+22+23 connected Bit 3-7 : unused" ::= { wtWebioEA24oemOutputPortEntry 3 } wtWebioEA24oemPortOutputSafetyState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output" ::= { wtWebioEA24oemOutputPortEntry 4 } wtWebioEA24oemPortLogicInputMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA24oemPortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA24oemPortLogicInputInverter) 3. Logical combination (wtWebioEA24oemPortLogicFunction) 4. Inverting the result if necessary (wtWebioEA24oemPortLogicOutputInverter) OCTET 1: unused OCTET 2: Bit 0-7 : inputs 16 - 23 OCTET 3: Bit 0-7 : inputs 8 - 15 OCTET 4: Bit 0-7 : inputs 0 - 7" ::= { wtWebioEA24oemOutputPortEntry 5 } wtWebioEA24oemPortLogicInputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: Bit 0-7 : inputs 16 - 23 OCTET 3: Bit 0-7 : inputs 8 - 15 OCTET 4: Bit 0-7 : inputs 0 - 7" ::= { wtWebioEA24oemOutputPortEntry 6 } wtWebioEA24oemPortLogicFunction OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused" ::= { wtWebioEA24oemOutputPortEntry 7 } wtWebioEA24oemPortLogicOutputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused" ::= { wtWebioEA24oemOutputPortEntry 8 } wtWebioEA24oemPortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtWebioEA24oemOutputPortEntry 9 } wtWebioEA24oemPortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtWebioEA24oemPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : ungenutzt" ::= { wtWebioEA24oemOutputPortEntry 10 } -- wtWebioEA24oemManufact Group ---------------------------- wtWebioEA24oemMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebioEA24oemManufact 1 } wtWebioEA24oemMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebioEA24oemManufact 2 } wtWebioEA24oemMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebioEA24oemManufact 3 } wtWebioEA24oemMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebioEA24oemManufact 4 } wtWebioEA24oemMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebioEA24oemManufact 5 } -- wtWebioEA24oemDiag Group ---------------------------- wtWebioEA24oemDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebioEA24oemDiag 1 } wtWebioEA24oemDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebioEA24oemDiag 2 } wtWebioEA24oemDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebioEA24oemDiagErrorMessage. Errors are numbered from 1 to wtWebioEA24oemDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA24oemDiagErrorMessage." ::= { wtWebioEA24oemDiag 3 } wtWebioEA24oemDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebioEA24oemDiagErrorIndex as an index, the appropriate message is available." ::= { wtWebioEA24oemDiag 4 } wtWebioEA24oemDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebioEA24oemDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebioEA24oemAlert1 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 53 wtWebioEA24oemAlert2 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 54 wtWebioEA24oemAlert3 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 55 wtWebioEA24oemAlert4 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 56 wtWebioEA24oemAlert5 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 57 wtWebioEA24oemAlert6 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 58 wtWebioEA24oemAlert7 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 59 wtWebioEA24oemAlert8 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 60 wtWebioEA24oemAlert9 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 61 wtWebioEA24oemAlert10 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 62 wtWebioEA24oemAlert11 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 63 wtWebioEA24oemAlert12 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 64 wtWebioEA24oemAlert13 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 13 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 13" --#SUMMARY "Alarm 13: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 65 wtWebioEA24oemAlert14 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 14 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 14" --#SUMMARY "Alarm 14: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 66 wtWebioEA24oemAlert15 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 15 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 15" --#SUMMARY "Alarm 15: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 67 wtWebioEA24oemAlert16 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 16 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 16" --#SUMMARY "Alarm 16: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 68 wtWebioEA24oemAlert17 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebioEA24oemAlert18 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebioEA24oemAlert19 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebioEA24oemAlert20 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebioEA24oemAlert21 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebioEA24oemAlert22 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebioEA24oemAlert23 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebioEA24oemAlert24 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebioEA24oemAlert25 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtWebioEA24oemAlert26 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtWebioEA24oemAlert27 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebioEA24oemAlert28 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebioEA24oemAlert29 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 13 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 13" --#SUMMARY "Release Alarm 13: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 83 wtWebioEA24oemAlert30 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 14 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 14" --#SUMMARY "Release Alarm 14: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 84 wtWebioEA24oemAlert31 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 15 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 15" --#SUMMARY "Release Alarm 15: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 85 wtWebioEA24oemAlert32 TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 16 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 16" --#SUMMARY "Release Alarm 16: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 86 wtWebioEA24oemAlertDiag TRAP-TYPE ENTERPRISE wtWebioEA24oem VARIABLES { wtWebioEA24oemDiagErrorIndex, wtWebioEA24oemDiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diag/error message was generated, the SNMP-Trap-Enable bit is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebio577xxEA12x6RelInOut Group ------------------------ wtWebio577xxEA12x6RelInputs OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtWebio577xxEA12x6RelInOut 1 } wtWebio577xxEA12x6RelOutputs OBJECT-TYPE SYNTAX INTEGER (1..6) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent outputs." ::= { wtWebio577xxEA12x6RelInOut 2 } -- Input Interface Table wtWebio577xxEA12x6RelInputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebio577xxEA12x6RelInOut 3 } wtWebio577xxEA12x6RelInputEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x6RelInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtWebio577xxEA12x6RelInputNo } ::= { wtWebio577xxEA12x6RelInputTable 1 } WtWebio577xxEA12x6RelInputEntry ::= SEQUENCE { wtWebio577xxEA12x6RelInputNo INTEGER, wtWebio577xxEA12x6RelInputCounter INTEGER, wtWebio577xxEA12x6RelInputCounterClear INTEGER, wtWebio577xxEA12x6RelInputState INTEGER } wtWebio577xxEA12x6RelInputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebio577xxEA12x6RelInputEntry 1 } wtWebio577xxEA12x6RelInputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebio577xxEA12x6RelInputEntry 2 } wtWebio577xxEA12x6RelInputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtWebio577xxEA12x6RelInputEntry 3 } wtWebio577xxEA12x6RelInputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of a single input bit, 0-OFF, 1-ON." ::= { wtWebio577xxEA12x6RelInputEntry 4 } wtWebio577xxEA12x6RelInputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-6: Digital outputs 0-6" ::= { wtWebio577xxEA12x6RelInOut 4 } -- Output Interface Table wtWebio577xxEA12x6RelOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtWebio577xxEA12x6RelInOut 5 } wtWebio577xxEA12x6RelOutputEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x6RelOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtWebio577xxEA12x6RelOutputNo } ::= { wtWebio577xxEA12x6RelOutputTable 1 } WtWebio577xxEA12x6RelOutputEntry ::= SEQUENCE { wtWebio577xxEA12x6RelOutputNo INTEGER, wtWebio577xxEA12x6RelOutputState INTEGER } wtWebio577xxEA12x6RelOutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtWebio577xxEA12x6RelOutputEntry 1 } wtWebio577xxEA12x6RelOutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of a single output bit, 0-OFF, 1-ON." ::= { wtWebio577xxEA12x6RelOutputEntry 2 } wtWebio577xxEA12x6RelOutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-6: Digital outputs 0-6" ::= { wtWebio577xxEA12x6RelInOut 6 } wtWebio577xxEA12x6RelSetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4 : Bit 0-6: Mask for digital outputs 0-6 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8 : Bit 0-6: Mask for digital outputs 0-6" ::= { wtWebio577xxEA12x6RelInOut 7 } -- wtWebio577xxEA12x6RelSessCntrl Group -------------------------------- wtWebio577xxEA12x6RelSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebio577xxEA12x6RelSessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebio577xxEA12x6RelSessCntrl 1 } wtWebio577xxEA12x6RelSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebio577xxEA12x6RelSessCntrl 2 } wtWebio577xxEA12x6RelSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebio577xxEA12x6RelSessCntrl 3 } wtWebio577xxEA12x6RelSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebio577xxEA12x6RelSessCntrl 4 } wtWebio577xxEA12x6RelSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebio577xxEA12x6RelSessCntrl 5 } -- wtWebio577xxEA12x6RelText Group ------------------------ wtWebio577xxEA12x6RelDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebio577xxEA12x6RelText 1 } wtWebio577xxEA12x6RelDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebio577xxEA12x6RelText 2 } wtWebio577xxEA12x6RelDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebio577xxEA12x6RelText 3 } wtWebio577xxEA12x6RelDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebio577xxEA12x6RelText 4 } -- wtWebio577xxEA12x6RelTimeZone Group ---------------------------- wtWebio577xxEA12x6RelTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebio577xxEA12x6RelTimeZone 1 } wtWebio577xxEA12x6RelTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebio577xxEA12x6RelTimeZone 2 } wtWebio577xxEA12x6RelTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebio577xxEA12x6RelTimeZone 3 } wtWebio577xxEA12x6RelStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebio577xxEA12x6RelTimeZone 4 } wtWebio577xxEA12x6RelStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebio577xxEA12x6RelTimeZone 5 } wtWebio577xxEA12x6RelStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebio577xxEA12x6RelTimeZone 6 } wtWebio577xxEA12x6RelStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA12x6RelStartMonth-January(1), wtWebio577xxEA12x6RelStartMonth-February(2), wtWebio577xxEA12x6RelStartMonth-March(3), wtWebio577xxEA12x6RelStartMonth-April(4), wtWebio577xxEA12x6RelStartMonth-May(5), wtWebio577xxEA12x6RelStartMonth-June(6), wtWebio577xxEA12x6RelStartMonth-July(7), wtWebio577xxEA12x6RelStartMonth-August(8), wtWebio577xxEA12x6RelStartMonth-September(9), wtWebio577xxEA12x6RelStartMonth-October(10), wtWebio577xxEA12x6RelStartMonth-November(11), wtWebio577xxEA12x6RelStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebio577xxEA12x6RelTimeZone 7 } wtWebio577xxEA12x6RelStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA12x6RelStartMode-first(1), wtWebio577xxEA12x6RelStartMode-second(2), wtWebio577xxEA12x6RelStartMode-third(3), wtWebio577xxEA12x6RelStartMode-fourth(4), wtWebio577xxEA12x6RelStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebio577xxEA12x6RelTimeZone 8 } wtWebio577xxEA12x6RelStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA12x6RelStartWday-Sunday(1), wtWebio577xxEA12x6RelStartWday-Monday(2), wtWebio577xxEA12x6RelStartWday-Tuesday(3), wtWebio577xxEA12x6RelStartWday-Thursday(4), wtWebio577xxEA12x6RelStartWday-Wednesday(5), wtWebio577xxEA12x6RelStartWday-Friday(6), wtWebio577xxEA12x6RelStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebio577xxEA12x6RelTimeZone 9 } wtWebio577xxEA12x6RelStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebio577xxEA12x6RelTimeZone 10 } wtWebio577xxEA12x6RelStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebio577xxEA12x6RelTimeZone 11 } wtWebio577xxEA12x6RelStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA12x6RelStopMonth-January(1), wtWebio577xxEA12x6RelStopMonth-February(2), wtWebio577xxEA12x6RelStopMonth-March(3), wtWebio577xxEA12x6RelStopMonth-April(4), wtWebio577xxEA12x6RelStopMonth-May(5), wtWebio577xxEA12x6RelStopMonth-June(6), wtWebio577xxEA12x6RelStopMonth-July(7), wtWebio577xxEA12x6RelStopMonth-August(8), wtWebio577xxEA12x6RelStopMonth-September(9), wtWebio577xxEA12x6RelStopMonth-October(10), wtWebio577xxEA12x6RelStopMonth-November(11), wtWebio577xxEA12x6RelStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebio577xxEA12x6RelTimeZone 12 } wtWebio577xxEA12x6RelStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA12x6RelStopMode-first(1), wtWebio577xxEA12x6RelStopMode-second(2), wtWebio577xxEA12x6RelStopMode-third(3), wtWebio577xxEA12x6RelStopMode-fourth(4), wtWebio577xxEA12x6RelStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebio577xxEA12x6RelTimeZone 13 } wtWebio577xxEA12x6RelStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA12x6RelStopWday-Sunday(1), wtWebio577xxEA12x6RelStopWday-Monday(2), wtWebio577xxEA12x6RelStopWday-Tuesday(3), wtWebio577xxEA12x6RelStopWday-Thursday(4), wtWebio577xxEA12x6RelStopWday-Wednesday(5), wtWebio577xxEA12x6RelStopWday-Friday(6), wtWebio577xxEA12x6RelStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebio577xxEA12x6RelTimeZone 14 } wtWebio577xxEA12x6RelStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebio577xxEA12x6RelTimeZone 15 } wtWebio577xxEA12x6RelStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebio577xxEA12x6RelTimeZone 16 } -- wtWebio577xxEA12x6RelTimeServer Group ---------------------------- wtWebio577xxEA12x6RelTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebio577xxEA12x6RelTimeServer 1 } wtWebio577xxEA12x6RelTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebio577xxEA12x6RelTimeServer 2 } wtWebio577xxEA12x6RelTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebio577xxEA12x6RelTimeServer 3 } wtWebio577xxEA12x6RelTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebio577xxEA12x6RelTimeServer 4 } -- wtWebio577xxEA12x6RelDeviceClock Group ---------------------------- wtWebio577xxEA12x6RelClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebio577xxEA12x6RelDeviceClock 1 } wtWebio577xxEA12x6RelClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebio577xxEA12x6RelDeviceClock 2 } wtWebio577xxEA12x6RelClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebio577xxEA12x6RelDeviceClock 3 } wtWebio577xxEA12x6RelClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebio577xxEA12x6RelClockMonth-January(1), wtWebio577xxEA12x6RelClockMonth-February(2), wtWebio577xxEA12x6RelClockMonth-March(3), wtWebio577xxEA12x6RelClockMonth-April(4), wtWebio577xxEA12x6RelClockMonth-May(5), wtWebio577xxEA12x6RelClockMonth-June(6), wtWebio577xxEA12x6RelClockMonth-July(7), wtWebio577xxEA12x6RelClockMonth-August(8), wtWebio577xxEA12x6RelClockMonth-September(9), wtWebio577xxEA12x6RelClockMonth-October(10), wtWebio577xxEA12x6RelClockMonth-November(11), wtWebio577xxEA12x6RelClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebio577xxEA12x6RelDeviceClock 4 } wtWebio577xxEA12x6RelClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebio577xxEA12x6RelDeviceClock 5 } -- wtWebio577xxEA12x6RelNetwork Group ------------------------ wtWebio577xxEA12x6RelIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebio577xxEA12x6RelNetwork 1 } wtWebio577xxEA12x6RelSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebio577xxEA12x6RelNetwork 2 } wtWebio577xxEA12x6RelGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebio577xxEA12x6RelNetwork 3 } wtWebio577xxEA12x6RelDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebio577xxEA12x6RelNetwork 4 } wtWebio577xxEA12x6RelDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebio577xxEA12x6RelNetwork 5 } wtWebio577xxEA12x6RelAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebio577xxEA12x6RelNetwork 6 } -- wtWebio577xxEA12x6RelHTTP Group -------------------------------- wtWebio577xxEA12x6RelStartup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebio577xxEA12x6RelHTTP 1 } wtWebio577xxEA12x6RelGetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebio577xxEA12x6RelHTTP 2 } wtWebio577xxEA12x6RelHttpInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebio577xxEA12x6RelHTTP 3 } wtWebio577xxEA12x6RelHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebio577xxEA12x6RelHTTP 4 } -- wtWebio577xxEA12x6RelMail Group -------------------------------- wtWebio577xxEA12x6RelMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebio577xxEA12x6RelMail 1 } wtWebio577xxEA12x6RelMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebio577xxEA12x6RelMail 2 } wtWebio577xxEA12x6RelMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebio577xxEA12x6RelMail 3 } wtWebio577xxEA12x6RelMailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebio577xxEA12x6RelMail 4 } wtWebio577xxEA12x6RelMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebio577xxEA12x6RelMail 5 } wtWebio577xxEA12x6RelMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebio577xxEA12x6RelMail 6 } wtWebio577xxEA12x6RelMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebio577xxEA12x6RelMail 7 } wtWebio577xxEA12x6RelMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebio577xxEA12x6RelMail 8 } -- wtWebio577xxEA12x6RelSnmp Group -------------------------------- wtWebio577xxEA12x6RelSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebio577xxEA12x6RelSNMP 1 } wtWebio577xxEA12x6RelSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebio577xxEA12x6RelSNMP 2 } wtWebio577xxEA12x6RelSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebio577xxEA12x6RelSNMP 3 } wtWebio577xxEA12x6RelSnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebio577xxEA12x6RelSNMP 4 } wtWebio577xxEA12x6RelSnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtWebio577xxEA12x6RelSNMP 5 } wtWebio577xxEA12x6RelSnmpSystemTrapManagerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the system trap." ::= { wtWebio577xxEA12x6RelSNMP 6 } -- wtWebio577xxEA12x6RelUDP Group -------------------------------- wtWebio577xxEA12x6RelUdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebio577xxEA12x6RelUDP 1 } wtWebio577xxEA12x6RelUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebio577xxEA12x6RelUDP 2 } wtWebio577xxEA12x6RelUdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebio577xxEA12x6RelUDP 3 } -- wtWebio577xxEA12x6RelBinary Group -------------------------------- wtWebio577xxEA12x6RelBinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebio577xxEA12x6RelBinary 1 } -- Binary Interface Table wtWebio577xxEA12x6RelBinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelBinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebio577xxEA12x6RelBinary 2 } wtWebio577xxEA12x6RelBinaryIfEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x6RelBinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebio577xxEA12x6RelBinaryModeNo } ::= { wtWebio577xxEA12x6RelBinaryIfTable 1 } WtWebio577xxEA12x6RelBinaryIfEntry ::= SEQUENCE { wtWebio577xxEA12x6RelBinaryModeNo INTEGER } wtWebio577xxEA12x6RelBinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebio577xxEA12x6RelBinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebio577xxEA12x6RelBinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelBinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebio577xxEA12x6RelBinary 3 } wtWebio577xxEA12x6RelBinaryEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x6RelBinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebio577xxEA12x6RelBinaryModeNo } ::= { wtWebio577xxEA12x6RelBinaryTable 1 } WtWebio577xxEA12x6RelBinaryEntry ::= SEQUENCE { wtWebio577xxEA12x6RelBinaryOperationMode OCTET STRING, wtWebio577xxEA12x6RelBinaryTcpServerLocalPort INTEGER, wtWebio577xxEA12x6RelBinaryTcpServerInputTrigger OCTET STRING, wtWebio577xxEA12x6RelBinaryTcpServerApplicationMode OCTET STRING, wtWebio577xxEA12x6RelBinaryTcpClientLocalPort INTEGER, wtWebio577xxEA12x6RelBinaryTcpClientServerPort INTEGER, wtWebio577xxEA12x6RelBinaryTcpClientServerIpAddr OCTET STRING, wtWebio577xxEA12x6RelBinaryTcpClientServerPassword OCTET STRING, wtWebio577xxEA12x6RelBinaryTcpClientInactivity INTEGER, wtWebio577xxEA12x6RelBinaryTcpClientInputTrigger OCTET STRING, wtWebio577xxEA12x6RelBinaryTcpClientInterval INTEGER, wtWebio577xxEA12x6RelBinaryTcpClientApplicationMode OCTET STRING, wtWebio577xxEA12x6RelBinaryUdpPeerLocalPort INTEGER, wtWebio577xxEA12x6RelBinaryUdpPeerRemotePort INTEGER, wtWebio577xxEA12x6RelBinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebio577xxEA12x6RelBinaryUdpPeerInputTrigger OCTET STRING, wtWebio577xxEA12x6RelBinaryUdpPeerInterval INTEGER, wtWebio577xxEA12x6RelBinaryUdpPeerApplicationMode OCTET STRING, wtWebio577xxEA12x6RelBinaryConnectedPort INTEGER, wtWebio577xxEA12x6RelBinaryConnectedIpAddr IpAddress, wtWebio577xxEA12x6RelBinaryTcpServerClientHttpPort INTEGER, wtWebio577xxEA12x6RelBinaryTcpClientServerHttpPort INTEGER, wtWebio577xxEA12x6RelBinaryTcpClientServerUserName OCTET STRING } wtWebio577xxEA12x6RelBinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebio577xxEA12x6RelBinaryEntry 1 } wtWebio577xxEA12x6RelBinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebio577xxEA12x6RelBinaryEntry 2 } wtWebio577xxEA12x6RelBinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebio577xxEA12x6RelBinaryEntry 3 } wtWebio577xxEA12x6RelBinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebio577xxEA12x6RelBinaryEntry 4 } wtWebio577xxEA12x6RelBinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebio577xxEA12x6RelBinaryEntry 5 } wtWebio577xxEA12x6RelBinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebio577xxEA12x6RelBinaryEntry 6 } wtWebio577xxEA12x6RelBinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebio577xxEA12x6RelBinaryEntry 7 } wtWebio577xxEA12x6RelBinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebio577xxEA12x6RelBinaryEntry 8 } wtWebio577xxEA12x6RelBinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebio577xxEA12x6RelBinaryEntry 9 } wtWebio577xxEA12x6RelBinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebio577xxEA12x6RelBinaryEntry 10 } wtWebio577xxEA12x6RelBinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebio577xxEA12x6RelBinaryEntry 11 } wtWebio577xxEA12x6RelBinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebio577xxEA12x6RelBinaryEntry 12 } wtWebio577xxEA12x6RelBinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebio577xxEA12x6RelBinaryEntry 13 } wtWebio577xxEA12x6RelBinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebio577xxEA12x6RelBinaryEntry 14 } wtWebio577xxEA12x6RelBinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebio577xxEA12x6RelBinaryEntry 15 } wtWebio577xxEA12x6RelBinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-6: Digital inputs 0-6" ::= { wtWebio577xxEA12x6RelBinaryEntry 16 } wtWebio577xxEA12x6RelBinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebio577xxEA12x6RelBinaryEntry 17 } wtWebio577xxEA12x6RelBinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebio577xxEA12x6RelBinaryEntry 18 } wtWebio577xxEA12x6RelBinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebio577xxEA12x6RelBinaryEntry 19 } wtWebio577xxEA12x6RelBinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebio577xxEA12x6RelBinaryEntry 20 } wtWebio577xxEA12x6RelBinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebio577xxEA12x6RelBinaryEntry 21 } wtWebio577xxEA12x6RelBinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebio577xxEA12x6RelBinaryEntry 22 } wtWebio577xxEA12x6RelBinaryTcpClientServerUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "User Name to login at the remote server, if authentication needed." ::= { wtWebio577xxEA12x6RelBinaryEntry 23 } -- wtWebio577xxEA12x6RelSyslog Group -------------------------------- wtWebio577xxEA12x6RelSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebio577xxEA12x6RelSyslog 1 } wtWebio577xxEA12x6RelSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebio577xxEA12x6RelSyslog 2 } wtWebio577xxEA12x6RelSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebio577xxEA12x6RelSyslog 3 } wtWebio577xxEA12x6RelSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebio577xxEA12x6RelSyslog 4 } -- wtWebio577xxEA12x6RelFTP Group -------------------------------- wtWebio577xxEA12x6RelFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebio577xxEA12x6RelFTP 1 } wtWebio577xxEA12x6RelFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebio577xxEA12x6RelFTP 2 } wtWebio577xxEA12x6RelFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebio577xxEA12x6RelFTP 3 } wtWebio577xxEA12x6RelFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebio577xxEA12x6RelFTP 4 } wtWebio577xxEA12x6RelFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebio577xxEA12x6RelFTP 5 } wtWebio577xxEA12x6RelFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebio577xxEA12x6RelFTP 6 } wtWebio577xxEA12x6RelFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebio577xxEA12x6RelFTP 7 } -- wtWebio577xxEA12x6RelMQTT Group -------------------------------- wtWebio577xxEA12x6RelMQTTEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 7 enables MQTT: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-6: unused Bit 7 : MQTT enable" ::= { wtWebio577xxEA12x6RelMQTT 1 } wtWebio577xxEA12x6RelMQTTBrockerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP-address of the MQTT-Server." ::= { wtWebio577xxEA12x6RelMQTT 2 } wtWebio577xxEA12x6RelMQTTUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT login user name." ::= { wtWebio577xxEA12x6RelMQTT 3 } wtWebio577xxEA12x6RelMQTTPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT login password." ::= { wtWebio577xxEA12x6RelMQTT 4 } wtWebio577xxEA12x6RelMQTTLocalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Local port number." ::= { wtWebio577xxEA12x6RelMQTT 5 } wtWebio577xxEA12x6RelMQTTBrokerServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Server port number." ::= { wtWebio577xxEA12x6RelMQTT 6 } wtWebio577xxEA12x6RelMQTTInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Ping intervall, if no data has to be send: time in seconds." ::= { wtWebio577xxEA12x6RelMQTT 7 } wtWebio577xxEA12x6RelMQTTLastWillEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activate MQTT LastWill message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will enable" ::= { wtWebio577xxEA12x6RelMQTT 8 } wtWebio577xxEA12x6RelMQTTLastWillTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will Topic." ::= { wtWebio577xxEA12x6RelMQTT 9 } wtWebio577xxEA12x6RelMQTTLastWillMsg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will message." ::= { wtWebio577xxEA12x6RelMQTT 10 } wtWebio577xxEA12x6RelMQTTLastWillQoS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded MQTT Publish QoS: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused" ::= { wtWebio577xxEA12x6RelMQTT 11 } wtWebio577xxEA12x6RelMQTTLastWillRetain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded MQTT Publish Retain properties: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused" ::= { wtWebio577xxEA12x6RelMQTT 12 } wtWebio577xxEA12x6RelMQTTLastWillConnectEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activate MQTT LastWill Connect message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will connect message enable" ::= { wtWebio577xxEA12x6RelMQTT 13 } wtWebio577xxEA12x6RelMQTTLastWillConnectMsg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will Connect message will be send with the QoS and Retain settings of the LastWill message." ::= { wtWebio577xxEA12x6RelMQTT 14 } -- wtWebio577xxEA1x1REST Group -------------------------------- wtWebio577xxEA12x6RelRESTEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activates REST: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : REST enable" ::= { wtWebio577xxEA12x6RelREST 1 } wtWebio577xxEA12x6RelRESTDigestAuthEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activates Digest-Authentification: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Digest Auth enable" ::= { wtWebio577xxEA12x6RelREST 2 } -- wtWebio577xxEA12x6RelOutputMode Group -------------------------------- -- OutputMode Table wtWebio577xxEA12x6RelOutputModeTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelOutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of output mode configurations dependent on the output indices." ::= { wtWebio577xxEA12x6RelOutputMode 1 } wtWebio577xxEA12x6RelOutputModeEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x6RelOutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output mode configurations of the individual outputs." INDEX { wtWebio577xxEA12x6RelOutputNo } ::= { wtWebio577xxEA12x6RelOutputModeTable 1 } WtWebio577xxEA12x6RelOutputModeEntry ::= SEQUENCE { wtWebio577xxEA12x6RelOutputModeBit OCTET STRING } wtWebio577xxEA12x6RelOutputModeBit OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebio577xxEA12x6RelOutputModeEntry 1 } wtWebio577xxEA12x6RelSafetyTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined." ::= { wtWebio577xxEA12x6RelOutputMode 2 } -- wtWebio577xxEA12x6RelAlarm Group ---------------------------- wtWebio577xxEA12x6RelAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebio577xxEA12x6RelAlarm 1 } -- Alarm Interface Table wtWebio577xxEA12x6RelAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebio577xxEA12x6RelAlarm 2 } wtWebio577xxEA12x6RelAlarmIfEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x6RelAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebio577xxEA12x6RelAlarmNo } ::= { wtWebio577xxEA12x6RelAlarmIfTable 1 } WtWebio577xxEA12x6RelAlarmIfEntry ::= SEQUENCE { wtWebio577xxEA12x6RelAlarmNo INTEGER } wtWebio577xxEA12x6RelAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtWebio577xxEA12x6RelAlarmIfEntry 1 } -- Alarm Table wtWebio577xxEA12x6RelAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebio577xxEA12x6RelAlarm 3 } wtWebio577xxEA12x6RelAlarmEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x6RelAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebio577xxEA12x6RelAlarmNo } ::= { wtWebio577xxEA12x6RelAlarmTable 1 } WtWebio577xxEA12x6RelAlarmEntry ::= SEQUENCE { wtWebio577xxEA12x6RelAlarmInputTrigger OCTET STRING, wtWebio577xxEA12x6RelAlarmOutputTrigger OCTET STRING, wtWebio577xxEA12x6RelAlarmSystemTrigger OCTET STRING, wtWebio577xxEA12x6RelAlarmMaxCounterValue OCTET STRING, wtWebio577xxEA12x6RelAlarmInterval OCTET STRING, wtWebio577xxEA12x6RelAlarmEnable OCTET STRING, wtWebio577xxEA12x6RelAlarmMailAddr OCTET STRING, wtWebio577xxEA12x6RelAlarmMailSubject OCTET STRING, wtWebio577xxEA12x6RelAlarmMailText OCTET STRING, wtWebio577xxEA12x6RelAlarmSnmpManagerIP OCTET STRING, wtWebio577xxEA12x6RelAlarmSnmpTrapText OCTET STRING, wtWebio577xxEA12x6RelAlarmUdpIpAddr OCTET STRING, wtWebio577xxEA12x6RelAlarmUdpPort INTEGER, wtWebio577xxEA12x6RelAlarmUdpText OCTET STRING, wtWebio577xxEA12x6RelAlarmTcpIpAddr OCTET STRING, wtWebio577xxEA12x6RelAlarmTcpPort INTEGER, wtWebio577xxEA12x6RelAlarmTcpText OCTET STRING, wtWebio577xxEA12x6RelAlarmSyslogIpAddr OCTET STRING, wtWebio577xxEA12x6RelAlarmSyslogPort INTEGER, wtWebio577xxEA12x6RelAlarmSyslogText OCTET STRING, wtWebio577xxEA12x6RelAlarmFtpDataPort OCTET STRING, wtWebio577xxEA12x6RelAlarmFtpFileName OCTET STRING, wtWebio577xxEA12x6RelAlarmFtpText OCTET STRING, wtWebio577xxEA12x6RelAlarmFtpOption OCTET STRING, wtWebio577xxEA12x6RelAlarmTimerCron OCTET STRING, wtWebio577xxEA12x6RelAlarmMailReleaseSubject OCTET STRING, wtWebio577xxEA12x6RelAlarmMailReleaseText OCTET STRING, wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText OCTET STRING, wtWebio577xxEA12x6RelAlarmUdpReleaseText OCTET STRING, wtWebio577xxEA12x6RelAlarmTcpReleaseText OCTET STRING, wtWebio577xxEA12x6RelAlarmSyslogReleaseText OCTET STRING, wtWebio577xxEA12x6RelAlarmFtpReleaseText OCTET STRING, wtWebio577xxEA12x6RelAlarmGlobalEnable OCTET STRING, wtWebio577xxEA12x6RelAlarmCombinationLogic OCTET STRING, wtWebio577xxEA12x6RelAlarmTrgMqttTopic OCTET STRING, wtWebio577xxEA12x6RelAlarmTrgMqttTopicText OCTET STRING, wtWebio577xxEA12x6RelAlarmHttpReqAuthEnable OCTET STRING, wtWebio577xxEA12x6RelAlarmHttpReqAuthUser OCTET STRING, wtWebio577xxEA12x6RelAlarmHttpReqAuthPassword OCTET STRING, wtWebio577xxEA12x6RelAlarmHttpReqSetUrl OCTET STRING, wtWebio577xxEA12x6RelAlarmHttpReqClearUrl OCTET STRING, wtWebio577xxEA12x6RelAlarmHttpReqServerPort INTEGER, wtWebio577xxEA12x6RelAlarmMqttTopicPath OCTET STRING, wtWebio577xxEA12x6RelAlarmMqttTopicSetTopic OCTET STRING, wtWebio577xxEA12x6RelAlarmMqttTopicClear OCTET STRING, wtWebio577xxEA12x6RelAlarmSetOutputsOwn OCTET STRING, wtWebio577xxEA12x6RelAlarmSetOutputsServerIp OCTET STRING, wtWebio577xxEA12x6RelAlarmSetOutputsServerPort INTEGER, wtWebio577xxEA12x6RelAlarmSetOutputsServerPassword OCTET STRING, wtWebio577xxEA12x6RelAlarmSetOutputsServerOutputs OCTET STRING, wtWebio577xxEA12x6RelAlarmSetOutputsDest OCTET STRING, wtWebio577xxEA12x6RelAlarmSnmpManagerPort INTEGER, wtWebio577xxEA12x6RelAlarmMqttQoS OCTET STRING, wtWebio577xxEA12x6RelAlarmMqttRetain OCTET STRING } wtWebio577xxEA12x6RelAlarmInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3, Bit 0-3: Mask for digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Mask for digital inputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7, Bit 0-3: Level of digital inputs 8-11 Bit 4-7: unused OCTET 8, Bit 0-7: Level of digital inputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unsused OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11 Bit 12-15 : unused OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7" ::= { wtWebio577xxEA12x6RelAlarmEntry 1 } wtWebio577xxEA12x6RelAlarmOutputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4 : Bit 0-6: Mask for digital outputs 0-6 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8 : Bit 0-6: Level of digital outputs 0-6 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 11: unused OCTET 12: Bit 0-6 : ANY bits of digital inputs 0-6" ::= { wtWebio577xxEA12x6RelAlarmEntry 2 } wtWebio577xxEA12x6RelAlarmSystemTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control" ::= { wtWebio577xxEA12x6RelAlarmEntry 3 } wtWebio577xxEA12x6RelAlarmMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebio577xxEA12x6RelAlarmInputTrigger are not considered." ::= { wtWebio577xxEA12x6RelAlarmEntry 4 } wtWebio577xxEA12x6RelAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebio577xxEA12x6RelAlarmEntry 5 } wtWebio577xxEA12x6RelAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Bit 0: UDP enable Bit1-7: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable Bit 3: Syslog Messages enable Bit 4: FTP enable Bit 5: HTTP Request enable Bit 6 MQTT Publish enable Bit 7: Set Outputs" ::= { wtWebio577xxEA12x6RelAlarmEntry 6 } wtWebio577xxEA12x6RelAlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebio577xxEA12x6RelAlarmEntry 7 } wtWebio577xxEA12x6RelAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebio577xxEA12x6RelAlarmEntry 8 } wtWebio577xxEA12x6RelAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebio577xxEA12x6RelAlarmEntry 9 } wtWebio577xxEA12x6RelAlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebio577xxEA12x6RelAlarmEntry 10 } wtWebio577xxEA12x6RelAlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebio577xxEA12x6RelAlarmEntry 11 } wtWebio577xxEA12x6RelAlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebio577xxEA12x6RelAlarmEntry 12 } wtWebio577xxEA12x6RelAlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebio577xxEA12x6RelAlarmEntry 13 } wtWebio577xxEA12x6RelAlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebio577xxEA12x6RelAlarmEntry 14 } wtWebio577xxEA12x6RelAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebio577xxEA12x6RelAlarmEntry 15 } wtWebio577xxEA12x6RelAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebio577xxEA12x6RelAlarmEntry 16 } wtWebio577xxEA12x6RelAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebio577xxEA12x6RelAlarmEntry 17 } wtWebio577xxEA12x6RelAlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebio577xxEA12x6RelAlarmEntry 18 } wtWebio577xxEA12x6RelAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebio577xxEA12x6RelAlarmEntry 19 } wtWebio577xxEA12x6RelAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebio577xxEA12x6RelAlarmEntry 20 } wtWebio577xxEA12x6RelAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebio577xxEA12x6RelAlarmEntry 21 } wtWebio577xxEA12x6RelAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebio577xxEA12x6RelAlarmEntry 22 } wtWebio577xxEA12x6RelAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebio577xxEA12x6RelAlarmEntry 23 } wtWebio577xxEA12x6RelAlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebio577xxEA12x6RelAlarmEntry 24 } wtWebio577xxEA12x6RelAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebio577xxEA12x6RelAlarmEntry 25 } wtWebio577xxEA12x6RelAlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebio577xxEA12x6RelAlarmEntry 26 } wtWebio577xxEA12x6RelAlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebio577xxEA12x6RelAlarmEntry 27 } wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebio577xxEA12x6RelAlarmEntry 28 } wtWebio577xxEA12x6RelAlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebio577xxEA12x6RelAlarmEntry 29 } wtWebio577xxEA12x6RelAlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebio577xxEA12x6RelAlarmEntry 30 } wtWebio577xxEA12x6RelAlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebio577xxEA12x6RelAlarmEntry 31 } wtWebio577xxEA12x6RelAlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebio577xxEA12x6RelAlarmEntry 32 } wtWebio577xxEA12x6RelAlarmGlobalEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm activation: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Alarm enable" ::= { wtWebio577xxEA12x6RelAlarmEntry 34 } wtWebio577xxEA12x6RelAlarmCombinationLogic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded logic, all Input/Output-trigger will be combined: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : OR Bit 0 : AND" ::= { wtWebio577xxEA12x6RelAlarmEntry 58 } wtWebio577xxEA12x6RelAlarmTrgMqttTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT subscribe topic." ::= { wtWebio577xxEA12x6RelAlarmEntry 59 } wtWebio577xxEA12x6RelAlarmTrgMqttTopicText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Receiving this text from the MQTT Broker, Alarm will be triggered." ::= { wtWebio577xxEA12x6RelAlarmEntry 60 } wtWebio577xxEA12x6RelAlarmHttpReqAuthEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable" ::= { wtWebio577xxEA12x6RelAlarmEntry 61 } wtWebio577xxEA12x6RelAlarmHttpReqAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: User" ::= { wtWebio577xxEA12x6RelAlarmEntry 62 } wtWebio577xxEA12x6RelAlarmHttpReqAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Password" ::= { wtWebio577xxEA12x6RelAlarmEntry 63 } wtWebio577xxEA12x6RelAlarmHttpReqSetUrl OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Set URL" ::= { wtWebio577xxEA12x6RelAlarmEntry 64 } wtWebio577xxEA12x6RelAlarmHttpReqClearUrl OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Clear URL" ::= { wtWebio577xxEA12x6RelAlarmEntry 65 } wtWebio577xxEA12x6RelAlarmHttpReqServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Server Port" ::= { wtWebio577xxEA12x6RelAlarmEntry 66 } wtWebio577xxEA12x6RelAlarmMqttTopicPath OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic path" ::= { wtWebio577xxEA12x6RelAlarmEntry 67 } wtWebio577xxEA12x6RelAlarmMqttTopicSetTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic SET message" ::= { wtWebio577xxEA12x6RelAlarmEntry 68 } wtWebio577xxEA12x6RelAlarmMqttTopicClear OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic CLEAR message" ::= { wtWebio577xxEA12x6RelAlarmEntry 69 } wtWebio577xxEA12x6RelAlarmSetOutputsOwn OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4 : Bit 0-6: Mask for digital outputs 0-6 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8 : Bit 0-6: Level of digital outputs 0-6 OCTETS 9-12 are unused." ::= { wtWebio577xxEA12x6RelAlarmEntry 70 } wtWebio577xxEA12x6RelAlarmSetOutputsServerIp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Outputs: Server IP Address" ::= { wtWebio577xxEA12x6RelAlarmEntry 71 } wtWebio577xxEA12x6RelAlarmSetOutputsServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Set Outputs: Server Port" ::= { wtWebio577xxEA12x6RelAlarmEntry 72 } wtWebio577xxEA12x6RelAlarmSetOutputsServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Outputs: Server Pasword" ::= { wtWebio577xxEA12x6RelAlarmEntry 73 } wtWebio577xxEA12x6RelAlarmSetOutputsServerOutputs OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : Bit 0-3: Level of digital outputs 8-11 OCTET 4 : Bit 0-7: Mask for digital outputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : Bit 0-3: Level of digital outputs 8-11 OCTET 8 : Bit 0-7: Level of digital outputs 0-7 OCTETS 9-12 are unused." ::= { wtWebio577xxEA12x6RelAlarmEntry 74 } wtWebio577xxEA12x6RelAlarmSetOutputsDest OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Bit 0 = LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : set outputs of remote server. Bit 0 : set outputs of this WEB-IO" ::= { wtWebio577xxEA12x6RelAlarmEntry 75 } wtWebio577xxEA12x6RelAlarmSnmpManagerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebio577xxEA12x6RelAlarmEntry 76 } wtWebio577xxEA12x6RelAlarmMqttQoS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused" ::= { wtWebio577xxEA12x6RelAlarmEntry 77 } wtWebio577xxEA12x6RelAlarmMqttRetain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused" ::= { wtWebio577xxEA12x6RelAlarmEntry 78 } -- wtWebio577xxEA12x6RelPorts Group ---------------------------- -- Input Port Table wtWebio577xxEA12x6RelInputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebio577xxEA12x6RelPorts 1 } wtWebio577xxEA12x6RelInputPortEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x6RelInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebio577xxEA12x6RelInputNo } ::= { wtWebio577xxEA12x6RelInputPortTable 1 } WtWebio577xxEA12x6RelInputPortEntry ::= SEQUENCE { wtWebio577xxEA12x6RelPortInputName OCTET STRING, wtWebio577xxEA12x6RelPortInputText OCTET STRING, wtWebio577xxEA12x6RelPortInputMode OCTET STRING, wtWebio577xxEA12x6RelPortInputFilter INTEGER, wtWebio577xxEA12x6RelPortInputBicountPulsePolarity OCTET STRING, wtWebio577xxEA12x6RelPortInputBicountInactivTimeout INTEGER } wtWebio577xxEA12x6RelPortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebio577xxEA12x6RelInputPortEntry 1 } wtWebio577xxEA12x6RelPortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebio577xxEA12x6RelInputPortEntry 2 } wtWebio577xxEA12x6RelPortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. Selection for input 0-1: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Bidirectional counter enable Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable" ::= { wtWebio577xxEA12x6RelInputPortEntry 3 } wtWebio577xxEA12x6RelPortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebio577xxEA12x6RelInputPortEntry 4 } wtWebio577xxEA12x6RelPortInputBicountPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebio577xxEA12x6RelInputPortEntry 5 } wtWebio577xxEA12x6RelPortInputBicountInactivTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored." ::= { wtWebio577xxEA12x6RelInputPortEntry 6 } -- Output Port Table wtWebio577xxEA12x6RelOutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtWebio577xxEA12x6RelPorts 2 } wtWebio577xxEA12x6RelOutputPortEntry OBJECT-TYPE SYNTAX WtWebio577xxEA12x6RelOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtWebio577xxEA12x6RelOutputNo } ::= { wtWebio577xxEA12x6RelOutputPortTable 1 } WtWebio577xxEA12x6RelOutputPortEntry ::= SEQUENCE { wtWebio577xxEA12x6RelPortOutputName OCTET STRING, wtWebio577xxEA12x6RelPortOutputText OCTET STRING, wtWebio577xxEA12x6RelPortOutputGroupMode OCTET STRING, wtWebio577xxEA12x6RelPortOutputSafetyState OCTET STRING, wtWebio577xxEA12x6RelPortPulseDuration INTEGER, wtWebio577xxEA12x6RelPortPulsePolarity OCTET STRING } wtWebio577xxEA12x6RelPortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtWebio577xxEA12x6RelOutputPortEntry 1 } wtWebio577xxEA12x6RelPortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtWebio577xxEA12x6RelOutputPortEntry 2 } wtWebio577xxEA12x6RelPortOutputGroupMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "No function within this device." ::= { wtWebio577xxEA12x6RelOutputPortEntry 3 } wtWebio577xxEA12x6RelPortOutputSafetyState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4 Bit 0-6: Mask for digital output 0-6 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : Unused OCTET 8 Bit 0-6: Level of digital output 0-6" ::= { wtWebio577xxEA12x6RelOutputPortEntry 4 } wtWebio577xxEA12x6RelPortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtWebio577xxEA12x6RelOutputPortEntry 9 } wtWebio577xxEA12x6RelPortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtWebio577xxEA12x6RelPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebio577xxEA12x6RelOutputPortEntry 10 } -- wtWebio577xxEA12x6RelManufact Group ---------------------------- wtWebio577xxEA12x6RelMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebio577xxEA12x6RelManufact 1 } wtWebio577xxEA12x6RelMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebio577xxEA12x6RelManufact 2 } wtWebio577xxEA12x6RelMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebio577xxEA12x6RelManufact 3 } wtWebio577xxEA12x6RelMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebio577xxEA12x6RelManufact 4 } wtWebio577xxEA12x6RelMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebio577xxEA12x6RelManufact 5 } -- wtWebio577xxEA12x6RelDiag Group ---------------------------- wtWebio577xxEA12x6RelDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebio577xxEA12x6RelDiag 1 } wtWebio577xxEA12x6RelDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebio577xxEA12x6RelDiag 2 } wtWebio577xxEA12x6RelDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebio577xxEA12x6RelDiagErrorMessage. Errors are numbered from 1 to wtWebio577xxEA12x6RelDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebio577xxEA12x6RelDiagErrorMessage." ::= { wtWebio577xxEA12x6RelDiag 3 } wtWebio577xxEA12x6RelDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebio577xxEA12x6RelDiagErrorIndex as an index, the appropriate message is available." ::= { wtWebio577xxEA12x6RelDiag 4 } wtWebio577xxEA12x6RelDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebio577xxEA12x6RelDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebio577xxEA12x6RelAlert1 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtWebio577xxEA12x6RelAlert2 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtWebio577xxEA12x6RelAlert3 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtWebio577xxEA12x6RelAlert4 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtWebio577xxEA12x6RelAlert5 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtWebio577xxEA12x6RelAlert6 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtWebio577xxEA12x6RelAlert7 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtWebio577xxEA12x6RelAlert8 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtWebio577xxEA12x6RelAlert9 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtWebio577xxEA12x6RelAlert10 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtWebio577xxEA12x6RelAlert11 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtWebio577xxEA12x6RelAlert12 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtWebio577xxEA12x6RelAlert13 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebio577xxEA12x6RelAlert14 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebio577xxEA12x6RelAlert15 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebio577xxEA12x6RelAlert16 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebio577xxEA12x6RelAlert17 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebio577xxEA12x6RelAlert18 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebio577xxEA12x6RelAlert19 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebio577xxEA12x6RelAlert20 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebio577xxEA12x6RelAlert21 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtWebio577xxEA12x6RelAlert22 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtWebio577xxEA12x6RelAlert23 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebio577xxEA12x6RelAlert24 TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebio577xxEA12x6RelAlertDiag TRAP-TYPE ENTERPRISE wtWebio577xxEA12x6Rel VARIABLES { wtWebio577xxEA12x6RelDiagErrorIndex, wtWebio577xxEA12x6RelDiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebioEA12x6RelInOut Group ------------------------ wtWebioEA12x6RelInputs OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtWebioEA12x6RelInOut 1 } wtWebioEA12x6RelOutputs OBJECT-TYPE SYNTAX INTEGER (1..6) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent outputs." ::= { wtWebioEA12x6RelInOut 2 } -- Input Interface Table wtWebioEA12x6RelInputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebioEA12x6RelInOut 3 } wtWebioEA12x6RelInputEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtWebioEA12x6RelInputNo } ::= { wtWebioEA12x6RelInputTable 1 } WtWebioEA12x6RelInputEntry ::= SEQUENCE { wtWebioEA12x6RelInputNo INTEGER, wtWebioEA12x6RelInputCounter INTEGER, wtWebioEA12x6RelInputCounterClear INTEGER } wtWebioEA12x6RelInputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebioEA12x6RelInputEntry 1 } wtWebioEA12x6RelInputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebioEA12x6RelInputEntry 2 } wtWebioEA12x6RelInputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtWebioEA12x6RelInputEntry 3 } wtWebioEA12x6RelInputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebioEA12x6RelInOut 4 } -- Output Interface Table wtWebioEA12x6RelOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtWebioEA12x6RelInOut 5 } wtWebioEA12x6RelOutputEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtWebioEA12x6RelOutputNo } ::= { wtWebioEA12x6RelOutputTable 1 } WtWebioEA12x6RelOutputEntry ::= SEQUENCE { wtWebioEA12x6RelOutputNo INTEGER, wtWebioEA12x6RelOutputState INTEGER } wtWebioEA12x6RelOutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtWebioEA12x6RelOutputEntry 1 } wtWebioEA12x6RelOutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Setting and reading of the states of the outputs, 0-OFF, 1-ON." ::= { wtWebioEA12x6RelOutputEntry 2 } wtWebioEA12x6RelOutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-5: Digital outputs 0-5" ::= { wtWebioEA12x6RelInOut 6 } wtWebioEA12x6RelSetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4 : Bit 0-5: Mask for digital outputs 0-5 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8 : Bit 0-5: Level of digital outputs 0-5" ::= { wtWebioEA12x6RelInOut 7 } -- wtWebioEA12x6RelSessCntrl Group -------------------------------- wtWebioEA12x6RelSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebioEA12x6RelSessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebioEA12x6RelSessCntrl 1 } wtWebioEA12x6RelSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebioEA12x6RelSessCntrl 2 } wtWebioEA12x6RelSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebioEA12x6RelSessCntrl 3 } wtWebioEA12x6RelSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebioEA12x6RelSessCntrl 4 } wtWebioEA12x6RelSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebioEA12x6RelSessCntrl 5 } -- wtWebioEA12x6RelText Group ------------------------ wtWebioEA12x6RelDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebioEA12x6RelText 1 } wtWebioEA12x6RelDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebioEA12x6RelText 2 } wtWebioEA12x6RelDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebioEA12x6RelText 3 } wtWebioEA12x6RelDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebioEA12x6RelText 4 } -- wtWebioEA12x6RelTimeZone Group ---------------------------- wtWebioEA12x6RelTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebioEA12x6RelTimeZone 1 } wtWebioEA12x6RelTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebioEA12x6RelTimeZone 2 } wtWebioEA12x6RelTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebioEA12x6RelTimeZone 3 } wtWebioEA12x6RelStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebioEA12x6RelTimeZone 4 } wtWebioEA12x6RelStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebioEA12x6RelTimeZone 5 } wtWebioEA12x6RelStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebioEA12x6RelTimeZone 6 } wtWebioEA12x6RelStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x6RelStartMonth-January(1), wtWebioEA12x6RelStartMonth-February(2), wtWebioEA12x6RelStartMonth-March(3), wtWebioEA12x6RelStartMonth-April(4), wtWebioEA12x6RelStartMonth-May(5), wtWebioEA12x6RelStartMonth-June(6), wtWebioEA12x6RelStartMonth-July(7), wtWebioEA12x6RelStartMonth-August(8), wtWebioEA12x6RelStartMonth-September(9), wtWebioEA12x6RelStartMonth-October(10), wtWebioEA12x6RelStartMonth-November(11), wtWebioEA12x6RelStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebioEA12x6RelTimeZone 7 } wtWebioEA12x6RelStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x6RelStartMode-first(1), wtWebioEA12x6RelStartMode-second(2), wtWebioEA12x6RelStartMode-third(3), wtWebioEA12x6RelStartMode-fourth(4), wtWebioEA12x6RelStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebioEA12x6RelTimeZone 8 } wtWebioEA12x6RelStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x6RelStartWday-Sunday(1), wtWebioEA12x6RelStartWday-Monday(2), wtWebioEA12x6RelStartWday-Tuesday(3), wtWebioEA12x6RelStartWday-Thursday(4), wtWebioEA12x6RelStartWday-Wednesday(5), wtWebioEA12x6RelStartWday-Friday(6), wtWebioEA12x6RelStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebioEA12x6RelTimeZone 9 } wtWebioEA12x6RelStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA12x6RelTimeZone 10 } wtWebioEA12x6RelStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA12x6RelTimeZone 11 } wtWebioEA12x6RelStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x6RelStopMonth-January(1), wtWebioEA12x6RelStopMonth-February(2), wtWebioEA12x6RelStopMonth-March(3), wtWebioEA12x6RelStopMonth-April(4), wtWebioEA12x6RelStopMonth-May(5), wtWebioEA12x6RelStopMonth-June(6), wtWebioEA12x6RelStopMonth-July(7), wtWebioEA12x6RelStopMonth-August(8), wtWebioEA12x6RelStopMonth-September(9), wtWebioEA12x6RelStopMonth-October(10), wtWebioEA12x6RelStopMonth-November(11), wtWebioEA12x6RelStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebioEA12x6RelTimeZone 12 } wtWebioEA12x6RelStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x6RelStopMode-first(1), wtWebioEA12x6RelStopMode-second(2), wtWebioEA12x6RelStopMode-third(3), wtWebioEA12x6RelStopMode-fourth(4), wtWebioEA12x6RelStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebioEA12x6RelTimeZone 13 } wtWebioEA12x6RelStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x6RelStopWday-Sunday(1), wtWebioEA12x6RelStopWday-Monday(2), wtWebioEA12x6RelStopWday-Tuesday(3), wtWebioEA12x6RelStopWday-Thursday(4), wtWebioEA12x6RelStopWday-Wednesday(5), wtWebioEA12x6RelStopWday-Friday(6), wtWebioEA12x6RelStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebioEA12x6RelTimeZone 14 } wtWebioEA12x6RelStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA12x6RelTimeZone 15 } wtWebioEA12x6RelStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA12x6RelTimeZone 16 } -- wtWebioEA12x6RelTimeServer Group ---------------------------- wtWebioEA12x6RelTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebioEA12x6RelTimeServer 1 } wtWebioEA12x6RelTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebioEA12x6RelTimeServer 2 } wtWebioEA12x6RelTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebioEA12x6RelTimeServer 3 } wtWebioEA12x6RelTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebioEA12x6RelTimeServer 4 } -- wtWebioEA12x6RelDeviceClock Group ---------------------------- wtWebioEA12x6RelClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebioEA12x6RelDeviceClock 1 } wtWebioEA12x6RelClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebioEA12x6RelDeviceClock 2 } wtWebioEA12x6RelClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebioEA12x6RelDeviceClock 3 } wtWebioEA12x6RelClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x6RelClockMonth-January(1), wtWebioEA12x6RelClockMonth-February(2), wtWebioEA12x6RelClockMonth-March(3), wtWebioEA12x6RelClockMonth-April(4), wtWebioEA12x6RelClockMonth-May(5), wtWebioEA12x6RelClockMonth-June(6), wtWebioEA12x6RelClockMonth-July(7), wtWebioEA12x6RelClockMonth-August(8), wtWebioEA12x6RelClockMonth-September(9), wtWebioEA12x6RelClockMonth-October(10), wtWebioEA12x6RelClockMonth-November(11), wtWebioEA12x6RelClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebioEA12x6RelDeviceClock 4 } wtWebioEA12x6RelClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebioEA12x6RelDeviceClock 5 } -- wtWebioEA12x6RelNetwork Group ------------------------ wtWebioEA12x6RelIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebioEA12x6RelNetwork 1 } wtWebioEA12x6RelSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebioEA12x6RelNetwork 2 } wtWebioEA12x6RelGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebioEA12x6RelNetwork 3 } wtWebioEA12x6RelDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebioEA12x6RelNetwork 4 } wtWebioEA12x6RelDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebioEA12x6RelNetwork 5 } wtWebioEA12x6RelAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebioEA12x6RelNetwork 6 } -- wtWebioEA12x6RelHTTP Group -------------------------------- wtWebioEA12x6RelStartup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebioEA12x6RelHTTP 1 } wtWebioEA12x6RelGetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebioEA12x6RelHTTP 2 } wtWebioEA12x6RelHttpInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebioEA12x6RelHTTP 3 } wtWebioEA12x6RelHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebioEA12x6RelHTTP 4 } -- wtWebioEA12x6RelMail Group -------------------------------- wtWebioEA12x6RelMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebioEA12x6RelMail 1 } wtWebioEA12x6RelMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebioEA12x6RelMail 2 } wtWebioEA12x6RelMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebioEA12x6RelMail 3 } wtWebioEA12x6RelMailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebioEA12x6RelMail 4 } wtWebioEA12x6RelMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebioEA12x6RelMail 5 } wtWebioEA12x6RelMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebioEA12x6RelMail 6 } wtWebioEA12x6RelMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebioEA12x6RelMail 7 } wtWebioEA12x6RelMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebioEA12x6RelMail 8 } -- wtWebioEA12x6RelSnmp Group -------------------------------- wtWebioEA12x6RelSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebioEA12x6RelSNMP 1 } wtWebioEA12x6RelSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebioEA12x6RelSNMP 2 } wtWebioEA12x6RelSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebioEA12x6RelSNMP 3 } wtWebioEA12x6RelSnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebioEA12x6RelSNMP 4 } wtWebioEA12x6RelSnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtWebioEA12x6RelSNMP 5 } -- wtWebioEA12x6RelUdp Group -------------------------------- wtWebioEA12x6RelUdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebioEA12x6RelUDP 1 } wtWebioEA12x6RelUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebioEA12x6RelUDP 2 } wtWebioEA12x6RelUdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebioEA12x6RelUDP 3 } -- wtWebioEA12x6RelBinary Group -------------------------------- wtWebioEA12x6RelBinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebioEA12x6RelBinary 1 } -- Binary Interface Table wtWebioEA12x6RelBinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelBinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebioEA12x6RelBinary 2 } wtWebioEA12x6RelBinaryIfEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelBinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebioEA12x6RelBinaryModeNo } ::= { wtWebioEA12x6RelBinaryIfTable 1 } WtWebioEA12x6RelBinaryIfEntry ::= SEQUENCE { wtWebioEA12x6RelBinaryModeNo INTEGER } wtWebioEA12x6RelBinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebioEA12x6RelBinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebioEA12x6RelBinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelBinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebioEA12x6RelBinary 3 } wtWebioEA12x6RelBinaryEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelBinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebioEA12x6RelBinaryModeNo } ::= { wtWebioEA12x6RelBinaryTable 1 } WtWebioEA12x6RelBinaryEntry ::= SEQUENCE { wtWebioEA12x6RelBinaryOperationMode OCTET STRING, wtWebioEA12x6RelBinaryTcpServerLocalPort INTEGER, wtWebioEA12x6RelBinaryTcpServerInputTrigger OCTET STRING, wtWebioEA12x6RelBinaryTcpServerApplicationMode OCTET STRING, wtWebioEA12x6RelBinaryTcpClientLocalPort INTEGER, wtWebioEA12x6RelBinaryTcpClientServerPort INTEGER, wtWebioEA12x6RelBinaryTcpClientServerIpAddr OCTET STRING, wtWebioEA12x6RelBinaryTcpClientServerPassword OCTET STRING, wtWebioEA12x6RelBinaryTcpClientInactivity INTEGER, wtWebioEA12x6RelBinaryTcpClientInputTrigger OCTET STRING, wtWebioEA12x6RelBinaryTcpClientInterval INTEGER, wtWebioEA12x6RelBinaryTcpClientApplicationMode OCTET STRING, wtWebioEA12x6RelBinaryUdpPeerLocalPort INTEGER, wtWebioEA12x6RelBinaryUdpPeerRemotePort INTEGER, wtWebioEA12x6RelBinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebioEA12x6RelBinaryUdpPeerInputTrigger OCTET STRING, wtWebioEA12x6RelBinaryUdpPeerInterval INTEGER, wtWebioEA12x6RelBinaryUdpPeerApplicationMode OCTET STRING, wtWebioEA12x6RelBinaryConnectedPort INTEGER, wtWebioEA12x6RelBinaryConnectedIpAddr IpAddress, wtWebioEA12x6RelBinaryTcpServerClientHttpPort INTEGER, wtWebioEA12x6RelBinaryTcpClientServerHttpPort INTEGER } wtWebioEA12x6RelBinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebioEA12x6RelBinaryEntry 1 } wtWebioEA12x6RelBinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA12x6RelBinaryEntry 2 } wtWebioEA12x6RelBinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebioEA12x6RelBinaryEntry 3 } wtWebioEA12x6RelBinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA12x6RelBinaryEntry 4 } wtWebioEA12x6RelBinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA12x6RelBinaryEntry 5 } wtWebioEA12x6RelBinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebioEA12x6RelBinaryEntry 6 } wtWebioEA12x6RelBinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebioEA12x6RelBinaryEntry 7 } wtWebioEA12x6RelBinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebioEA12x6RelBinaryEntry 8 } wtWebioEA12x6RelBinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebioEA12x6RelBinaryEntry 9 } wtWebioEA12x6RelBinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebioEA12x6RelBinaryEntry 10 } wtWebioEA12x6RelBinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebioEA12x6RelBinaryEntry 11 } wtWebioEA12x6RelBinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA12x6RelBinaryEntry 12 } wtWebioEA12x6RelBinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA12x6RelBinaryEntry 13 } wtWebioEA12x6RelBinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebioEA12x6RelBinaryEntry 14 } wtWebioEA12x6RelBinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebioEA12x6RelBinaryEntry 15 } wtWebioEA12x6RelBinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebioEA12x6RelBinaryEntry 16 } wtWebioEA12x6RelBinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebioEA12x6RelBinaryEntry 17 } wtWebioEA12x6RelBinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA12x6RelBinaryEntry 18 } wtWebioEA12x6RelBinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebioEA12x6RelBinaryEntry 19 } wtWebioEA12x6RelBinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebioEA12x6RelBinaryEntry 20 } wtWebioEA12x6RelBinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebioEA12x6RelBinaryEntry 21 } wtWebioEA12x6RelBinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebioEA12x6RelBinaryEntry 22 } -- wtWebioEA12x6RelSyslog Group -------------------------------- wtWebioEA12x6RelSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebioEA12x6RelSyslog 1 } wtWebioEA12x6RelSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebioEA12x6RelSyslog 2 } wtWebioEA12x6RelSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebioEA12x6RelSyslog 3 } wtWebioEA12x6RelSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebioEA12x6RelSyslog 4 } -- wtWebioEA12x6RelFTP Group -------------------------------- wtWebioEA12x6RelFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebioEA12x6RelFTP 1 } wtWebioEA12x6RelFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioEA12x6RelFTP 2 } wtWebioEA12x6RelFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebioEA12x6RelFTP 3 } wtWebioEA12x6RelFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebioEA12x6RelFTP 4 } wtWebioEA12x6RelFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebioEA12x6RelFTP 5 } wtWebioEA12x6RelFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebioEA12x6RelFTP 6 } wtWebioEA12x6RelFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebioEA12x6RelFTP 7 } -- wtWebioEA12x6RelOutputMode Group -------------------------------- -- OutputMode Table wtWebioEA12x6RelOutputModeTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelOutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of output mode configurations dependent on the output indices." ::= { wtWebioEA12x6RelOutputMode 1 } wtWebioEA12x6RelOutputModeEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelOutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output mode configurations of the individual outputs." INDEX { wtWebioEA12x6RelOutputNo } ::= { wtWebioEA12x6RelOutputModeTable 1 } WtWebioEA12x6RelOutputModeEntry ::= SEQUENCE { wtWebioEA12x6RelOutputModeBit OCTET STRING } wtWebioEA12x6RelOutputModeBit OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebioEA12x6RelOutputModeEntry 1 } wtWebioEA12x6RelSafetyTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined." ::= { wtWebioEA12x6RelOutputMode 2 } -- wtWebioEA12x6RelAlarm Group ---------------------------- wtWebioEA12x6RelAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebioEA12x6RelAlarm 1 } -- Alarm Interface Table wtWebioEA12x6RelAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebioEA12x6RelAlarm 2 } wtWebioEA12x6RelAlarmIfEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebioEA12x6RelAlarmNo } ::= { wtWebioEA12x6RelAlarmIfTable 1 } WtWebioEA12x6RelAlarmIfEntry ::= SEQUENCE { wtWebioEA12x6RelAlarmNo INTEGER } wtWebioEA12x6RelAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtWebioEA12x6RelAlarmIfEntry 1 } -- Alarm Table wtWebioEA12x6RelAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebioEA12x6RelAlarm 3 } wtWebioEA12x6RelAlarmEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebioEA12x6RelAlarmNo } ::= { wtWebioEA12x6RelAlarmTable 1 } WtWebioEA12x6RelAlarmEntry ::= SEQUENCE { wtWebioEA12x6RelAlarmInputTrigger OCTET STRING, wtWebioEA12x6RelAlarmOutputTrigger OCTET STRING, wtWebioEA12x6RelAlarmSystemTrigger OCTET STRING, wtWebioEA12x6RelAlarmMaxCounterValue OCTET STRING, wtWebioEA12x6RelAlarmInterval OCTET STRING, wtWebioEA12x6RelAlarmEnable OCTET STRING, wtWebioEA12x6RelAlarmMailAddr OCTET STRING, wtWebioEA12x6RelAlarmMailSubject OCTET STRING, wtWebioEA12x6RelAlarmMailText OCTET STRING, wtWebioEA12x6RelAlarmSnmpManagerIP OCTET STRING, wtWebioEA12x6RelAlarmSnmpTrapText OCTET STRING, wtWebioEA12x6RelAlarmUdpIpAddr OCTET STRING, wtWebioEA12x6RelAlarmUdpPort INTEGER, wtWebioEA12x6RelAlarmUdpText OCTET STRING, wtWebioEA12x6RelAlarmTcpIpAddr OCTET STRING, wtWebioEA12x6RelAlarmTcpPort INTEGER, wtWebioEA12x6RelAlarmTcpText OCTET STRING, wtWebioEA12x6RelAlarmSyslogIpAddr OCTET STRING, wtWebioEA12x6RelAlarmSyslogPort INTEGER, wtWebioEA12x6RelAlarmSyslogText OCTET STRING, wtWebioEA12x6RelAlarmFtpDataPort OCTET STRING, wtWebioEA12x6RelAlarmFtpFileName OCTET STRING, wtWebioEA12x6RelAlarmFtpText OCTET STRING, wtWebioEA12x6RelAlarmFtpOption OCTET STRING, wtWebioEA12x6RelAlarmTimerCron OCTET STRING, wtWebioEA12x6RelAlarmMailReleaseSubject OCTET STRING, wtWebioEA12x6RelAlarmMailReleaseText OCTET STRING, wtWebioEA12x6RelAlarmSnmpTrapReleaseText OCTET STRING, wtWebioEA12x6RelAlarmUdpReleaseText OCTET STRING, wtWebioEA12x6RelAlarmTcpReleaseText OCTET STRING, wtWebioEA12x6RelAlarmSyslogReleaseText OCTET STRING, wtWebioEA12x6RelAlarmFtpReleaseText OCTET STRING } wtWebioEA12x6RelAlarmInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3, Bit 0-3: Mask for digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Mask for digital inputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7, Bit 0-3: Level of digital inputs 8-11 Bit 4-7: unused OCTET 8, Bit 0-7: Level of digital inputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11 Bit 12-15 : unused OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7" ::= { wtWebioEA12x6RelAlarmEntry 1 } wtWebioEA12x6RelAlarmOutputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-5: Mask for digital outputs 0-5 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-5: Level of digital outputs 0-5 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unused OCTET 11: unused OCTET 12: Bit 0-5: ANY bits of digital outputs 0-5" ::= { wtWebioEA12x6RelAlarmEntry 2 } wtWebioEA12x6RelAlarmSystemTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control" ::= { wtWebioEA12x6RelAlarmEntry 3 } wtWebioEA12x6RelAlarmMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA12x6RelAlarmInputTrigger are not considered." ::= { wtWebioEA12x6RelAlarmEntry 4 } wtWebioEA12x6RelAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebioEA12x6RelAlarmEntry 5 } wtWebioEA12x6RelAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused" ::= { wtWebioEA12x6RelAlarmEntry 6 } wtWebioEA12x6RelAlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebioEA12x6RelAlarmEntry 7 } wtWebioEA12x6RelAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA12x6RelAlarmEntry 8 } wtWebioEA12x6RelAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA12x6RelAlarmEntry 9 } wtWebioEA12x6RelAlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebioEA12x6RelAlarmEntry 10 } wtWebioEA12x6RelAlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA12x6RelAlarmEntry 11 } wtWebioEA12x6RelAlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA12x6RelAlarmEntry 12 } wtWebioEA12x6RelAlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA12x6RelAlarmEntry 13 } wtWebioEA12x6RelAlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA12x6RelAlarmEntry 14 } wtWebioEA12x6RelAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA12x6RelAlarmEntry 15 } wtWebioEA12x6RelAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA12x6RelAlarmEntry 16 } wtWebioEA12x6RelAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA12x6RelAlarmEntry 17 } wtWebioEA12x6RelAlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA12x6RelAlarmEntry 18 } wtWebioEA12x6RelAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA12x6RelAlarmEntry 19 } wtWebioEA12x6RelAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA12x6RelAlarmEntry 20 } wtWebioEA12x6RelAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebioEA12x6RelAlarmEntry 21 } wtWebioEA12x6RelAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebioEA12x6RelAlarmEntry 22 } wtWebioEA12x6RelAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA12x6RelAlarmEntry 23 } wtWebioEA12x6RelAlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebioEA12x6RelAlarmEntry 24 } wtWebioEA12x6RelAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebioEA12x6RelAlarmEntry 25 } wtWebioEA12x6RelAlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA12x6RelAlarmEntry 26 } wtWebioEA12x6RelAlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA12x6RelAlarmEntry 27 } wtWebioEA12x6RelAlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA12x6RelAlarmEntry 28 } wtWebioEA12x6RelAlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA12x6RelAlarmEntry 29 } wtWebioEA12x6RelAlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA12x6RelAlarmEntry 30 } wtWebioEA12x6RelAlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA12x6RelAlarmEntry 31 } wtWebioEA12x6RelAlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA12x6RelAlarmEntry 32 } -- wtWebioEA12x6RelPorts Group ---------------------------- -- Input Port Table wtWebioEA12x6RelInputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebioEA12x6RelPorts 1 } wtWebioEA12x6RelInputPortEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebioEA12x6RelInputNo } ::= { wtWebioEA12x6RelInputPortTable 1 } WtWebioEA12x6RelInputPortEntry ::= SEQUENCE { wtWebioEA12x6RelPortInputName OCTET STRING, wtWebioEA12x6RelPortInputText OCTET STRING, wtWebioEA12x6RelPortInputMode OCTET STRING, wtWebioEA12x6RelPortInputFilter INTEGER, wtWebioEA12x6RelPortInputBicountPulsePolarity OCTET STRING, wtWebioEA12x6RelPortInputBicountInactivTimeout INTEGER } wtWebioEA12x6RelPortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebioEA12x6RelInputPortEntry 1 } wtWebioEA12x6RelPortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebioEA12x6RelInputPortEntry 2 } wtWebioEA12x6RelPortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. Selection for input 0-3: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 3-7: unused Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable Selection for inputs 4-11: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on read Bit 0 : Change detection enable (default)" ::= { wtWebioEA12x6RelInputPortEntry 3 } wtWebioEA12x6RelPortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebioEA12x6RelInputPortEntry 4 } wtWebioEA12x6RelPortInputBicountPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA12x6RelInputPortEntry 5 } wtWebioEA12x6RelPortInputBicountInactivTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored." ::= { wtWebioEA12x6RelInputPortEntry 6 } -- Output Port Table wtWebioEA12x6RelOutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtWebioEA12x6RelPorts 2 } wtWebioEA12x6RelOutputPortEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtWebioEA12x6RelOutputNo } ::= { wtWebioEA12x6RelOutputPortTable 1 } WtWebioEA12x6RelOutputPortEntry ::= SEQUENCE { wtWebioEA12x6RelPortOutputName OCTET STRING, wtWebioEA12x6RelPortOutputText OCTET STRING, wtWebioEA12x6RelPortOutputGroupMode OCTET STRING, wtWebioEA12x6RelPortOutputSafetyState OCTET STRING, wtWebioEA12x6RelPortLogicInputMask OCTET STRING, wtWebioEA12x6RelPortLogicInputInverter OCTET STRING, wtWebioEA12x6RelPortLogicFunction OCTET STRING, wtWebioEA12x6RelPortLogicOutputInverter OCTET STRING, wtWebioEA12x6RelPortPulseDuration INTEGER, wtWebioEA12x6RelPortPulsePolarity OCTET STRING } wtWebioEA12x6RelPortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtWebioEA12x6RelOutputPortEntry 1 } wtWebioEA12x6RelPortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtWebioEA12x6RelOutputPortEntry 2 } wtWebioEA12x6RelPortOutputGroupMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Unused in this device 57634" ::= { wtWebioEA12x6RelOutputPortEntry 3 } wtWebioEA12x6RelPortOutputSafetyState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH=Relais closed, 0=LOW Relais open) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output" ::= { wtWebioEA12x6RelOutputPortEntry 4 } wtWebioEA12x6RelPortLogicInputMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA12x6RelPortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA12x6RelPortLogicInputInverter) 3. Logical combination (wtWebioEA12x6RelPortLogicFunction) 4. Inverting the result if necessary (wtWebioEA12x6RelPortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : inputs 8-11 Bit 4-7 : unused OCTET 4: Bit 0-7 : inputs 0-7" ::= { wtWebioEA12x6RelOutputPortEntry 5 } wtWebioEA12x6RelPortLogicInputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : inputs 8-11 Bit 4-7 : unused OCTET 4: Bit 0-7 : inputs 0-7" ::= { wtWebioEA12x6RelOutputPortEntry 6 } wtWebioEA12x6RelPortLogicFunction OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused" ::= { wtWebioEA12x6RelOutputPortEntry 7 } wtWebioEA12x6RelPortLogicOutputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused" ::= { wtWebioEA12x6RelOutputPortEntry 8 } wtWebioEA12x6RelPortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtWebioEA12x6RelOutputPortEntry 9 } wtWebioEA12x6RelPortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtWebioEA12x6RelPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA12x6RelOutputPortEntry 10 } -- wtWebioEA12x6RelManufact Group ---------------------------- wtWebioEA12x6RelMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebioEA12x6RelManufact 1 } wtWebioEA12x6RelMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebioEA12x6RelManufact 2 } wtWebioEA12x6RelMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebioEA12x6RelManufact 3 } wtWebioEA12x6RelMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebioEA12x6RelManufact 4 } wtWebioEA12x6RelMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebioEA12x6RelManufact 5 } wtWebioEA12x6RelMfOrderNo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer part number." ::= { wtWebioEA12x6RelManufact 6 } -- wtWebioEA12x6RelDiag Group ---------------------------- wtWebioEA12x6RelDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebioEA12x6RelDiag 1 } wtWebioEA12x6RelDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebioEA12x6RelDiag 2 } wtWebioEA12x6RelDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebioEA12x6RelDiagErrorMessage. Errors are numbered from 1 to wtWebioEA12x6RelDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA12x6RelDiagErrorMessage." ::= { wtWebioEA12x6RelDiag 3 } wtWebioEA12x6RelDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebioEA12x6RelDiagErrorIndex as an index, the appropriate message is available." ::= { wtWebioEA12x6RelDiag 4 } wtWebioEA12x6RelDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebioEA12x6RelDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebioEA12x6RelAlert1 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtWebioEA12x6RelAlert2 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtWebioEA12x6RelAlert3 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtWebioEA12x6RelAlert4 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtWebioEA12x6RelAlert5 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtWebioEA12x6RelAlert6 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtWebioEA12x6RelAlert7 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtWebioEA12x6RelAlert8 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtWebioEA12x6RelAlert9 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtWebioEA12x6RelAlert10 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtWebioEA12x6RelAlert11 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtWebioEA12x6RelAlert12 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtWebioEA12x6RelAlert13 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebioEA12x6RelAlert14 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebioEA12x6RelAlert15 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebioEA12x6RelAlert16 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebioEA12x6RelAlert17 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebioEA12x6RelAlert18 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebioEA12x6RelAlert19 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebioEA12x6RelAlert20 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebioEA12x6RelAlert21 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtWebioEA12x6RelAlert22 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtWebioEA12x6RelAlert23 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebioEA12x6RelAlert24 TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebioEA12x6RelAlertDiag TRAP-TYPE ENTERPRISE wtWebioEA12x6Rel VARIABLES { wtWebioEA12x6RelDiagErrorIndex, wtWebioEA12x6RelDiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebAlarm6x6InOut Group ------------------------ wtWebAlarm6x6Inputs OBJECT-TYPE SYNTAX INTEGER (1..6) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtWebAlarm6x6InOut 1 } wtWebAlarm6x6Outputs OBJECT-TYPE SYNTAX INTEGER (1..6) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent outputs." ::= { wtWebAlarm6x6InOut 2 } -- Input Interface Table wtWebAlarm6x6InputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebAlarm6x6InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebAlarm6x6InOut 3 } wtWebAlarm6x6InputEntry OBJECT-TYPE SYNTAX WtWebAlarm6x6InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtWebAlarm6x6InputNo } ::= { wtWebAlarm6x6InputTable 1 } WtWebAlarm6x6InputEntry ::= SEQUENCE { wtWebAlarm6x6InputNo INTEGER, wtWebAlarm6x6InputCounter INTEGER, wtWebAlarm6x6InputCounterClear INTEGER, wtWebAlarm6x6InputState INTEGER } wtWebAlarm6x6InputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebAlarm6x6InputEntry 1 } wtWebAlarm6x6InputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebAlarm6x6InputEntry 2 } wtWebAlarm6x6InputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtWebAlarm6x6InputEntry 3 } wtWebAlarm6x6InputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "States of the inputs, 0-OFF, 1-ON." ::= { wtWebAlarm6x6InputEntry 4 } wtWebAlarm6x6InputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-5: Digital inputs 0-5 Bit 6-7: unused" ::= { wtWebAlarm6x6InOut 4 } -- Output Interface Table wtWebAlarm6x6OutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebAlarm6x6OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtWebAlarm6x6InOut 5 } wtWebAlarm6x6OutputEntry OBJECT-TYPE SYNTAX WtWebAlarm6x6OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtWebAlarm6x6OutputNo } ::= { wtWebAlarm6x6OutputTable 1 } WtWebAlarm6x6OutputEntry ::= SEQUENCE { wtWebAlarm6x6OutputNo INTEGER, wtWebAlarm6x6OutputState INTEGER } wtWebAlarm6x6OutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtWebAlarm6x6OutputEntry 1 } wtWebAlarm6x6OutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "States of the outputs, 0-OFF, 1-ON." ::= { wtWebAlarm6x6OutputEntry 2 } wtWebAlarm6x6OutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-5: Digital outputs 0-5" ::= { wtWebAlarm6x6InOut 6 } -- Alarm Output Interface Table wtWebAlarm6x6AlarmOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebAlarm6x6AlarmOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices.." ::= { wtWebAlarm6x6InOut 8 } wtWebAlarm6x6AlarmOutputEntry OBJECT-TYPE SYNTAX WtWebAlarm6x6AlarmOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Index reference." INDEX { wtWebAlarm6x6AlarmNo } ::= { wtWebAlarm6x6AlarmOutputTable 1 } WtWebAlarm6x6AlarmOutputEntry ::= SEQUENCE { wtWebAlarm6x6AlarmOutputState INTEGER, wtWebAlarm6x6AlarmTriggerState INTEGER } wtWebAlarm6x6AlarmOutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "State of the alarm, 0-OFF, 1-ON." ::= { wtWebAlarm6x6AlarmOutputEntry 1 } wtWebAlarm6x6AlarmTriggerState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "State of the trigger condition, 0-OFF, 1-ON." ::= { wtWebAlarm6x6AlarmOutputEntry 2 } -- wtWebAlarm6x6SessCntrl Group -------------------------------- wtWebAlarm6x6SessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebAlarm6x6SessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebAlarm6x6SessCntrl 1 } wtWebAlarm6x6SessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebAlarm6x6SessCntrl 2 } wtWebAlarm6x6SessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebAlarm6x6SessCntrl 3 } wtWebAlarm6x6SessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebAlarm6x6SessCntrl 4 } wtWebAlarm6x6SessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebAlarm6x6SessCntrl 5 } -- wtWebAlarm6x6Text Group ------------------------ wtWebAlarm6x6DeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebAlarm6x6Text 1 } wtWebAlarm6x6DeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebAlarm6x6Text 2 } wtWebAlarm6x6DeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebAlarm6x6Text 3 } wtWebAlarm6x6DeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebAlarm6x6Text 4 } -- wtWebAlarm6x6TimeZone Group ---------------------------- wtWebAlarm6x6TzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebAlarm6x6TimeZone 1 } wtWebAlarm6x6TzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebAlarm6x6TimeZone 2 } wtWebAlarm6x6TzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebAlarm6x6TimeZone 3 } wtWebAlarm6x6StTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebAlarm6x6TimeZone 4 } wtWebAlarm6x6StTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebAlarm6x6TimeZone 5 } wtWebAlarm6x6StTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebAlarm6x6TimeZone 6 } wtWebAlarm6x6StTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebAlarm6x6StartMonth-January(1), wtWebAlarm6x6StartMonth-February(2), wtWebAlarm6x6StartMonth-March(3), wtWebAlarm6x6StartMonth-April(4), wtWebAlarm6x6StartMonth-May(5), wtWebAlarm6x6StartMonth-June(6), wtWebAlarm6x6StartMonth-July(7), wtWebAlarm6x6StartMonth-August(8), wtWebAlarm6x6StartMonth-September(9), wtWebAlarm6x6StartMonth-October(10), wtWebAlarm6x6StartMonth-November(11), wtWebAlarm6x6StartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebAlarm6x6TimeZone 7 } wtWebAlarm6x6StTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebAlarm6x6StartMode-first(1), wtWebAlarm6x6StartMode-second(2), wtWebAlarm6x6StartMode-third(3), wtWebAlarm6x6StartMode-fourth(4), wtWebAlarm6x6StartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebAlarm6x6TimeZone 8 } wtWebAlarm6x6StTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebAlarm6x6StartWday-Sunday(1), wtWebAlarm6x6StartWday-Monday(2), wtWebAlarm6x6StartWday-Tuesday(3), wtWebAlarm6x6StartWday-Thursday(4), wtWebAlarm6x6StartWday-Wednesday(5), wtWebAlarm6x6StartWday-Friday(6), wtWebAlarm6x6StartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebAlarm6x6TimeZone 9 } wtWebAlarm6x6StTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebAlarm6x6TimeZone 10 } wtWebAlarm6x6StTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebAlarm6x6TimeZone 11 } wtWebAlarm6x6StTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebAlarm6x6StopMonth-January(1), wtWebAlarm6x6StopMonth-February(2), wtWebAlarm6x6StopMonth-March(3), wtWebAlarm6x6StopMonth-April(4), wtWebAlarm6x6StopMonth-May(5), wtWebAlarm6x6StopMonth-June(6), wtWebAlarm6x6StopMonth-July(7), wtWebAlarm6x6StopMonth-August(8), wtWebAlarm6x6StopMonth-September(9), wtWebAlarm6x6StopMonth-October(10), wtWebAlarm6x6StopMonth-November(11), wtWebAlarm6x6StopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebAlarm6x6TimeZone 12 } wtWebAlarm6x6StTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebAlarm6x6StopMode-first(1), wtWebAlarm6x6StopMode-second(2), wtWebAlarm6x6StopMode-third(3), wtWebAlarm6x6StopMode-fourth(4), wtWebAlarm6x6StopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebAlarm6x6TimeZone 13 } wtWebAlarm6x6StTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebAlarm6x6StopWday-Sunday(1), wtWebAlarm6x6StopWday-Monday(2), wtWebAlarm6x6StopWday-Tuesday(3), wtWebAlarm6x6StopWday-Thursday(4), wtWebAlarm6x6StopWday-Wednesday(5), wtWebAlarm6x6StopWday-Friday(6), wtWebAlarm6x6StopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebAlarm6x6TimeZone 14 } wtWebAlarm6x6StTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebAlarm6x6TimeZone 15 } wtWebAlarm6x6StTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebAlarm6x6TimeZone 16 } -- wtWebAlarm6x6TimeServer Group ---------------------------- wtWebAlarm6x6TimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebAlarm6x6TimeServer 1 } wtWebAlarm6x6TimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebAlarm6x6TimeServer 2 } wtWebAlarm6x6TsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebAlarm6x6TimeServer 3 } wtWebAlarm6x6TsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebAlarm6x6TimeServer 4 } -- wtWebAlarm6x6DeviceClock Group ---------------------------- wtWebAlarm6x6ClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebAlarm6x6DeviceClock 1 } wtWebAlarm6x6ClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebAlarm6x6DeviceClock 2 } wtWebAlarm6x6ClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebAlarm6x6DeviceClock 3 } wtWebAlarm6x6ClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebAlarm6x6ClockMonth-January(1), wtWebAlarm6x6ClockMonth-February(2), wtWebAlarm6x6ClockMonth-March(3), wtWebAlarm6x6ClockMonth-April(4), wtWebAlarm6x6ClockMonth-May(5), wtWebAlarm6x6ClockMonth-June(6), wtWebAlarm6x6ClockMonth-July(7), wtWebAlarm6x6ClockMonth-August(8), wtWebAlarm6x6ClockMonth-September(9), wtWebAlarm6x6ClockMonth-October(10), wtWebAlarm6x6ClockMonth-November(11), wtWebAlarm6x6ClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebAlarm6x6DeviceClock 4 } wtWebAlarm6x6ClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebAlarm6x6DeviceClock 5 } -- wtWebAlarm6x6Network Group ------------------------ wtWebAlarm6x6IpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebAlarm6x6Network 1 } wtWebAlarm6x6SubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebAlarm6x6Network 2 } wtWebAlarm6x6Gateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebAlarm6x6Network 3 } wtWebAlarm6x6DnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebAlarm6x6Network 4 } wtWebAlarm6x6DnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebAlarm6x6Network 5 } wtWebAlarm6x6AddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebAlarm6x6Network 6 } -- wtWebAlarm6x6HTTP Group -------------------------------- wtWebAlarm6x6HttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebAlarm6x6HTTP 4 } -- wtWebAlarm6x6Mail Group -------------------------------- wtWebAlarm6x6MailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebAlarm6x6Mail 1 } wtWebAlarm6x6MailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebAlarm6x6Mail 2 } wtWebAlarm6x6MailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebAlarm6x6Mail 3 } wtWebAlarm6x6MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebAlarm6x6Mail 4 } wtWebAlarm6x6MailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebAlarm6x6Mail 5 } wtWebAlarm6x6MailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebAlarm6x6Mail 6 } wtWebAlarm6x6MailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebAlarm6x6Mail 7 } wtWebAlarm6x6MailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebAlarm6x6Mail 8 } -- wtWebAlarm6x6Snmp Group -------------------------------- wtWebAlarm6x6SnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebAlarm6x6SNMP 1 } wtWebAlarm6x6SnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebAlarm6x6SNMP 2 } wtWebAlarm6x6SnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebAlarm6x6SNMP 3 } wtWebAlarm6x6SnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebAlarm6x6SNMP 4 } wtWebAlarm6x6SnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtWebAlarm6x6SNMP 5 } -- wtWebAlarm6x6Udp Group -------------------------------- wtWebAlarm6x6UdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebAlarm6x6UDP 1 } wtWebAlarm6x6UdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebAlarm6x6UDP 2 } wtWebAlarm6x6UdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebAlarm6x6UDP 3 } -- wtWebAlarm6x6Syslog Group -------------------------------- wtWebAlarm6x6SyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebAlarm6x6Syslog 1 } wtWebAlarm6x6SyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebAlarm6x6Syslog 2 } wtWebAlarm6x6SyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebAlarm6x6Syslog 3 } wtWebAlarm6x6SyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebAlarm6x6Syslog 4 } -- wtWebAlarm6x6FTP Group -------------------------------- wtWebAlarm6x6FTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebAlarm6x6FTP 1 } wtWebAlarm6x6FTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebAlarm6x6FTP 2 } wtWebAlarm6x6FTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebAlarm6x6FTP 3 } wtWebAlarm6x6FTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebAlarm6x6FTP 4 } wtWebAlarm6x6FTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebAlarm6x6FTP 5 } wtWebAlarm6x6FTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebAlarm6x6FTP 6 } wtWebAlarm6x6FTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebAlarm6x6FTP 7 } -- wtWebAlarm6x6Alarm Group ---------------------------- wtWebAlarm6x6AlarmCount OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebAlarm6x6Alarm 1 } -- Alarm Interface Table wtWebAlarm6x6AlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebAlarm6x6AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebAlarm6x6Alarm 2 } wtWebAlarm6x6AlarmIfEntry OBJECT-TYPE SYNTAX WtWebAlarm6x6AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebAlarm6x6AlarmNo } ::= { wtWebAlarm6x6AlarmIfTable 1 } WtWebAlarm6x6AlarmIfEntry ::= SEQUENCE { wtWebAlarm6x6AlarmNo INTEGER } wtWebAlarm6x6AlarmNo OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtWebAlarm6x6AlarmIfEntry 1 } -- Alarm Table wtWebAlarm6x6AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebAlarm6x6AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebAlarm6x6Alarm 3 } wtWebAlarm6x6AlarmEntry OBJECT-TYPE SYNTAX WtWebAlarm6x6AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebAlarm6x6AlarmNo } ::= { wtWebAlarm6x6AlarmTable 1 } WtWebAlarm6x6AlarmEntry ::= SEQUENCE { wtWebAlarm6x6AlarmInputTrigger OCTET STRING, wtWebAlarm6x6AlarmMaxCounterValue OCTET STRING, wtWebAlarm6x6AlarmInterval OCTET STRING, wtWebAlarm6x6AlarmEnable OCTET STRING, wtWebAlarm6x6AlarmMailAddr OCTET STRING, wtWebAlarm6x6AlarmMailSubject OCTET STRING, wtWebAlarm6x6AlarmMailText OCTET STRING, wtWebAlarm6x6AlarmSnmpManagerIP OCTET STRING, wtWebAlarm6x6AlarmSnmpTrapText OCTET STRING, wtWebAlarm6x6AlarmUdpIpAddr OCTET STRING, wtWebAlarm6x6AlarmUdpPort INTEGER, wtWebAlarm6x6AlarmUdpText OCTET STRING, wtWebAlarm6x6AlarmTcpIpAddr OCTET STRING, wtWebAlarm6x6AlarmTcpPort INTEGER, wtWebAlarm6x6AlarmTcpText OCTET STRING, wtWebAlarm6x6AlarmSyslogIpAddr OCTET STRING, wtWebAlarm6x6AlarmSyslogPort INTEGER, wtWebAlarm6x6AlarmSyslogText OCTET STRING, wtWebAlarm6x6AlarmFtpDataPort OCTET STRING, wtWebAlarm6x6AlarmFtpFileName OCTET STRING, wtWebAlarm6x6AlarmFtpText OCTET STRING, wtWebAlarm6x6AlarmFtpOption OCTET STRING, wtWebAlarm6x6AlarmMailReleaseSubject OCTET STRING, wtWebAlarm6x6AlarmMailReleaseText OCTET STRING, wtWebAlarm6x6AlarmSnmpTrapReleaseText OCTET STRING, wtWebAlarm6x6AlarmUdpReleaseText OCTET STRING, wtWebAlarm6x6AlarmTcpReleaseText OCTET STRING, wtWebAlarm6x6AlarmSyslogReleaseText OCTET STRING, wtWebAlarm6x6AlarmFtpReleaseText OCTET STRING, wtWebAlarm6x6AlarmName OCTET STRING, wtWebAlarm6x6AlarmGlobalEnable OCTET STRING, wtWebAlarm6x6AlarmCounterClear OCTET STRING, wtWebAlarm6x6AlarmAckEnable OCTET STRING, wtWebAlarm6x6AlarmAckPort INTEGER, wtWebAlarm6x6AlarmSetPort INTEGER, wtWebAlarm6x6AlarmMailTrgClearSubject OCTET STRING, wtWebAlarm6x6AlarmMailTrgClearText OCTET STRING, wtWebAlarm6x6AlarmSnmpTrapTrgClearText OCTET STRING, wtWebAlarm6x6AlarmUdpTrgClearText OCTET STRING, wtWebAlarm6x6AlarmTcpTrgClearText OCTET STRING, wtWebAlarm6x6AlarmSyslogTrgClearText OCTET STRING, wtWebAlarm6x6AlarmFtpTrgClearText OCTET STRING, wtWebAlarm6x6AlarmMailTrapTxEnable OCTET STRING, wtWebAlarm6x6AlarmSnmpTrapTrapTxEnable OCTET STRING, wtWebAlarm6x6AlarmUdpTrapTxEnable OCTET STRING, wtWebAlarm6x6AlarmTcpTrapTxEnable OCTET STRING, wtWebAlarm6x6AlarmSyslogTrapTxEnable OCTET STRING, wtWebAlarm6x6AlarmFtpTrapTxEnable OCTET STRING } wtWebAlarm6x6AlarmInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3: unused OCTET 4, Bit 0-5: Mask for digital inputs 0-5 Bit 6-7: unused OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-5: Level of digital inputs 0-5 Bit 6-7: unused OCTETS 9-12 contain the counter bit (1=ON, 0=OFF). Inputs masked with the counter bit trigger an alarm when the corresponding counter reaching the wtWebAlarm6x6AlarmMaxCounterValue. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-5: Counter bits of digital inputs 0-5 Bit 6-7: unused." ::= { wtWebAlarm6x6AlarmEntry 1 } wtWebAlarm6x6AlarmMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebAlarm6x6AlarmInputTrigger are not considered." ::= { wtWebAlarm6x6AlarmEntry 4 } wtWebAlarm6x6AlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebAlarm6x6AlarmEntry 5 } wtWebAlarm6x6AlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Output Switch Enable Bit 1: Mail Enable Bit 2: SNMP Trap enable Bit 3: UDP enable Bit 4: unused Bit 5: TCP Client enable Bit 6: Syslog Messages enable Bit 7: FTP Client enable" ::= { wtWebAlarm6x6AlarmEntry 6 } wtWebAlarm6x6AlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebAlarm6x6AlarmEntry 7 } wtWebAlarm6x6AlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebAlarm6x6AlarmEntry 8 } wtWebAlarm6x6AlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebAlarm6x6AlarmEntry 9 } wtWebAlarm6x6AlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebAlarm6x6AlarmEntry 10 } wtWebAlarm6x6AlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebAlarm6x6AlarmEntry 11 } wtWebAlarm6x6AlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebAlarm6x6AlarmEntry 12 } wtWebAlarm6x6AlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebAlarm6x6AlarmEntry 13 } wtWebAlarm6x6AlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebAlarm6x6AlarmEntry 14 } wtWebAlarm6x6AlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebAlarm6x6AlarmEntry 15 } wtWebAlarm6x6AlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebAlarm6x6AlarmEntry 16 } wtWebAlarm6x6AlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebAlarm6x6AlarmEntry 17 } wtWebAlarm6x6AlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebAlarm6x6AlarmEntry 18 } wtWebAlarm6x6AlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebAlarm6x6AlarmEntry 19 } wtWebAlarm6x6AlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebAlarm6x6AlarmEntry 20 } wtWebAlarm6x6AlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebAlarm6x6AlarmEntry 21 } wtWebAlarm6x6AlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebAlarm6x6AlarmEntry 22 } wtWebAlarm6x6AlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebAlarm6x6AlarmEntry 23 } wtWebAlarm6x6AlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebAlarm6x6AlarmEntry 24 } wtWebAlarm6x6AlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebAlarm6x6AlarmEntry 26 } wtWebAlarm6x6AlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebAlarm6x6AlarmEntry 27 } wtWebAlarm6x6AlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebAlarm6x6AlarmEntry 28 } wtWebAlarm6x6AlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebAlarm6x6AlarmEntry 29 } wtWebAlarm6x6AlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebAlarm6x6AlarmEntry 30 } wtWebAlarm6x6AlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebAlarm6x6AlarmEntry 31 } wtWebAlarm6x6AlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebAlarm6x6AlarmEntry 32 } wtWebAlarm6x6AlarmName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the alarm." ::= { wtWebAlarm6x6AlarmEntry 33 } wtWebAlarm6x6AlarmGlobalEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm activation: Die OCTETS werden bitweise interpretiert. Bit 0 entspricht dem LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Alarm enable" ::= { wtWebAlarm6x6AlarmEntry 34 } wtWebAlarm6x6AlarmCounterClear OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on Alarm acknowledge Bit 0 : Counter clear on Alarm send" ::= { wtWebAlarm6x6AlarmEntry 35 } wtWebAlarm6x6AlarmAckEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Software acknowledge enable Bit 0 : Hardware acknowledge enable" ::= { wtWebAlarm6x6AlarmEntry 36 } wtWebAlarm6x6AlarmAckPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of the input, which clears the alarm (1-6)." ::= { wtWebAlarm6x6AlarmEntry 37 } wtWebAlarm6x6AlarmSetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of the output, which will be set by this alarm (1-6). The configuration of pulse mode and polarity defined in the port output section is used." ::= { wtWebAlarm6x6AlarmEntry 38 } wtWebAlarm6x6AlarmMailTrgClearSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebAlarm6x6AlarmEntry 39 } wtWebAlarm6x6AlarmMailTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebAlarm6x6AlarmEntry 40 } wtWebAlarm6x6AlarmSnmpTrapTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebAlarm6x6AlarmEntry 41 } wtWebAlarm6x6AlarmUdpTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebAlarm6x6AlarmEntry 42 } wtWebAlarm6x6AlarmTcpTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebAlarm6x6AlarmEntry 43 } wtWebAlarm6x6AlarmSyslogTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebAlarm6x6AlarmEntry 44 } wtWebAlarm6x6AlarmFtpTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebAlarm6x6AlarmEntry 45 } wtWebAlarm6x6AlarmMailTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtWebAlarm6x6AlarmEntry 46 } wtWebAlarm6x6AlarmSnmpTrapTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtWebAlarm6x6AlarmEntry 47 } wtWebAlarm6x6AlarmUdpTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtWebAlarm6x6AlarmEntry 48 } wtWebAlarm6x6AlarmTcpTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtWebAlarm6x6AlarmEntry 49 } wtWebAlarm6x6AlarmSyslogTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtWebAlarm6x6AlarmEntry 50 } wtWebAlarm6x6AlarmFtpTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtWebAlarm6x6AlarmEntry 51 } -- wtWebAlarm6x6Ports Group ---------------------------- -- Input Port Table wtWebAlarm6x6InputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebAlarm6x6InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebAlarm6x6Ports 1 } wtWebAlarm6x6InputPortEntry OBJECT-TYPE SYNTAX WtWebAlarm6x6InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebAlarm6x6InputNo } ::= { wtWebAlarm6x6InputPortTable 1 } WtWebAlarm6x6InputPortEntry ::= SEQUENCE { wtWebAlarm6x6PortInputName OCTET STRING, wtWebAlarm6x6PortInputText OCTET STRING, wtWebAlarm6x6PortInputFilter INTEGER, wtWebAlarm6x6PortInputPulsePolarity OCTET STRING, wtWebAlarm6x6PortInputCounterSet INTEGER } wtWebAlarm6x6PortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebAlarm6x6InputPortEntry 1 } wtWebAlarm6x6PortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebAlarm6x6InputPortEntry 2 } wtWebAlarm6x6PortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebAlarm6x6InputPortEntry 4 } wtWebAlarm6x6PortInputPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebAlarm6x6InputPortEntry 5 } wtWebAlarm6x6PortInputCounterSet OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Writing to this variable presets the counter, while reading returns the actual value." ::= { wtWebAlarm6x6InputPortEntry 7 } -- Output Port Table wtWebAlarm6x6OutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebAlarm6x6OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtWebAlarm6x6Ports 2 } wtWebAlarm6x6OutputPortEntry OBJECT-TYPE SYNTAX WtWebAlarm6x6OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtWebAlarm6x6OutputNo } ::= { wtWebAlarm6x6OutputPortTable 1 } WtWebAlarm6x6OutputPortEntry ::= SEQUENCE { wtWebAlarm6x6PortOutputName OCTET STRING, wtWebAlarm6x6PortOutputText OCTET STRING, wtWebAlarm6x6PortPulseDuration INTEGER, wtWebAlarm6x6PortPulsePolarity OCTET STRING } wtWebAlarm6x6PortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtWebAlarm6x6OutputPortEntry 1 } wtWebAlarm6x6PortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtWebAlarm6x6OutputPortEntry 2 } wtWebAlarm6x6PortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/100 sec. Setting this value to zero, disables the pulse output." ::= { wtWebAlarm6x6OutputPortEntry 9 } wtWebAlarm6x6PortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtWebAlarm6x6PortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebAlarm6x6OutputPortEntry 10 } -- wtWebAlarm6x6Manufact Group ---------------------------- wtWebAlarm6x6MfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebAlarm6x6Manufact 1 } wtWebAlarm6x6MfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebAlarm6x6Manufact 2 } wtWebAlarm6x6MfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebAlarm6x6Manufact 3 } wtWebAlarm6x6MfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebAlarm6x6Manufact 4 } wtWebAlarm6x6MfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebAlarm6x6Manufact 5 } wtWebAlarm6x6MfOrderNo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer part number." ::= { wtWebAlarm6x6Manufact 6 } -- wtWebAlarm6x6Diag Group ---------------------------- wtWebAlarm6x6DiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebAlarm6x6Diag 1 } wtWebAlarm6x6DiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebAlarm6x6Diag 2 } wtWebAlarm6x6DiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebAlarm6x6DiagErrorMessage. Errors are numbered from 1 to wtWebAlarm6x6DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebAlarm6x6DiagErrorMessage." ::= { wtWebAlarm6x6Diag 3 } wtWebAlarm6x6DiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebAlarm6x6DiagErrorIndex as an index, the appropriate message is available." ::= { wtWebAlarm6x6Diag 4 } wtWebAlarm6x6DiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebAlarm6x6Diag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebAlarm6x6Alert1 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtWebAlarm6x6Alert2 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtWebAlarm6x6Alert3 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtWebAlarm6x6Alert4 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtWebAlarm6x6Alert5 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtWebAlarm6x6Alert6 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtWebAlarm6x6Alert7 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtWebAlarm6x6Alert8 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtWebAlarm6x6Alert9 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtWebAlarm6x6Alert10 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtWebAlarm6x6Alert11 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtWebAlarm6x6Alert12 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtWebAlarm6x6Alert13 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebAlarm6x6Alert14 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebAlarm6x6Alert15 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebAlarm6x6Alert16 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebAlarm6x6Alert17 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebAlarm6x6Alert18 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebAlarm6x6Alert19 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebAlarm6x6Alert20 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebAlarm6x6Alert21 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtWebAlarm6x6Alert22 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtWebAlarm6x6Alert23 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebAlarm6x6Alert24 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebAlarm6x6Alert25 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 91 wtWebAlarm6x6Alert26 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 92 wtWebAlarm6x6Alert27 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 93 wtWebAlarm6x6Alert28 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 94 wtWebAlarm6x6Alert29 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 95 wtWebAlarm6x6Alert30 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 96 wtWebAlarm6x6Alert31 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 97 wtWebAlarm6x6Alert32 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 98 wtWebAlarm6x6Alert33 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 99 wtWebAlarm6x6Alert34 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 100 wtWebAlarm6x6Alert35 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 101 wtWebAlarm6x6Alert36 TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 102 wtWebAlarm6x6AlertDiag TRAP-TYPE ENTERPRISE wtWebAlarm6x6 VARIABLES { wtWebAlarm6x6DiagErrorIndex, wtWebAlarm6x6DiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebAlarm Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebCount6InOut Group ------------------------ wtWebCount6Inputs OBJECT-TYPE SYNTAX INTEGER (1..6) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtWebCount6InOut 1 } wtWebCount6Outputs OBJECT-TYPE SYNTAX INTEGER (1..6) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent outputs." ::= { wtWebCount6InOut 2 } -- Input Interface Table wtWebCount6InputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebCount6InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebCount6InOut 3 } wtWebCount6InputEntry OBJECT-TYPE SYNTAX WtWebCount6InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtWebCount6InputNo } ::= { wtWebCount6InputTable 1 } WtWebCount6InputEntry ::= SEQUENCE { wtWebCount6InputNo INTEGER, wtWebCount6InputCounter INTEGER, wtWebCount6InputCounterClear INTEGER, wtWebCount6InputState INTEGER } wtWebCount6InputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebCount6InputEntry 1 } wtWebCount6InputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebCount6InputEntry 2 } wtWebCount6InputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtWebCount6InputEntry 3 } wtWebCount6InputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Tates of the inputs, 0-OFF, 1-ON." ::= { wtWebCount6InputEntry 4 } wtWebCount6InputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-5: Digital inputs 0-5 Bit 6-7: unused" ::= { wtWebCount6InOut 4 } -- Report Output Interface Table wtWebCount6ReportOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebCount6ReportOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of Report indices.." ::= { wtWebCount6InOut 8 } wtWebCount6ReportOutputEntry OBJECT-TYPE SYNTAX WtWebCount6ReportOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Index reference." INDEX { wtWebCount6ReportNo } ::= { wtWebCount6ReportOutputTable 1 } WtWebCount6ReportOutputEntry ::= SEQUENCE { wtWebCount6ReportOutputState INTEGER, wtWebCount6ReportTriggerState INTEGER } wtWebCount6ReportOutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "State of the Report, 0-OFF, 1-ON." ::= { wtWebCount6ReportOutputEntry 1 } wtWebCount6ReportTriggerState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "State of the trigger condition, 0-OFF, 1-ON." ::= { wtWebCount6ReportOutputEntry 2 } -- wtWebCount6SessCntrl Group -------------------------------- wtWebCount6SessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebCount6SessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebCount6SessCntrl 1 } wtWebCount6SessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebCount6SessCntrl 2 } wtWebCount6SessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebCount6SessCntrl 3 } wtWebCount6SessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebCount6SessCntrl 4 } wtWebCount6SessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebCount6SessCntrl 5 } -- wtWebCount6Text Group ------------------------ wtWebCount6DeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebCount6Text 1 } wtWebCount6DeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebCount6Text 2 } wtWebCount6DeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebCount6Text 3 } wtWebCount6DeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebCount6Text 4 } -- wtWebCount6TimeZone Group ---------------------------- wtWebCount6TzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebCount6TimeZone 1 } wtWebCount6TzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebCount6TimeZone 2 } wtWebCount6TzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebCount6TimeZone 3 } wtWebCount6StTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebCount6TimeZone 4 } wtWebCount6StTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebCount6TimeZone 5 } wtWebCount6StTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebCount6TimeZone 6 } wtWebCount6StTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebCount6StartMonth-January(1), wtWebCount6StartMonth-February(2), wtWebCount6StartMonth-March(3), wtWebCount6StartMonth-April(4), wtWebCount6StartMonth-May(5), wtWebCount6StartMonth-June(6), wtWebCount6StartMonth-July(7), wtWebCount6StartMonth-August(8), wtWebCount6StartMonth-September(9), wtWebCount6StartMonth-October(10), wtWebCount6StartMonth-November(11), wtWebCount6StartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebCount6TimeZone 7 } wtWebCount6StTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebCount6StartMode-first(1), wtWebCount6StartMode-second(2), wtWebCount6StartMode-third(3), wtWebCount6StartMode-fourth(4), wtWebCount6StartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebCount6TimeZone 8 } wtWebCount6StTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebCount6StartWday-Sunday(1), wtWebCount6StartWday-Monday(2), wtWebCount6StartWday-Tuesday(3), wtWebCount6StartWday-Thursday(4), wtWebCount6StartWday-Wednesday(5), wtWebCount6StartWday-Friday(6), wtWebCount6StartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebCount6TimeZone 9 } wtWebCount6StTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebCount6TimeZone 10 } wtWebCount6StTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebCount6TimeZone 11 } wtWebCount6StTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebCount6StopMonth-January(1), wtWebCount6StopMonth-February(2), wtWebCount6StopMonth-March(3), wtWebCount6StopMonth-April(4), wtWebCount6StopMonth-May(5), wtWebCount6StopMonth-June(6), wtWebCount6StopMonth-July(7), wtWebCount6StopMonth-August(8), wtWebCount6StopMonth-September(9), wtWebCount6StopMonth-October(10), wtWebCount6StopMonth-November(11), wtWebCount6StopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebCount6TimeZone 12 } wtWebCount6StTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebCount6StopMode-first(1), wtWebCount6StopMode-second(2), wtWebCount6StopMode-third(3), wtWebCount6StopMode-fourth(4), wtWebCount6StopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebCount6TimeZone 13 } wtWebCount6StTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebCount6StopWday-Sunday(1), wtWebCount6StopWday-Monday(2), wtWebCount6StopWday-Tuesday(3), wtWebCount6StopWday-Thursday(4), wtWebCount6StopWday-Wednesday(5), wtWebCount6StopWday-Friday(6), wtWebCount6StopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebCount6TimeZone 14 } wtWebCount6StTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebCount6TimeZone 15 } wtWebCount6StTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebCount6TimeZone 16 } -- wtWebCount6TimeServer Group ---------------------------- wtWebCount6TimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebCount6TimeServer 1 } wtWebCount6TimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebCount6TimeServer 2 } wtWebCount6TsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebCount6TimeServer 3 } wtWebCount6TsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebCount6TimeServer 4 } -- wtWebCount6DeviceClock Group ---------------------------- wtWebCount6ClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebCount6DeviceClock 1 } wtWebCount6ClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebCount6DeviceClock 2 } wtWebCount6ClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebCount6DeviceClock 3 } wtWebCount6ClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebCount6ClockMonth-January(1), wtWebCount6ClockMonth-February(2), wtWebCount6ClockMonth-March(3), wtWebCount6ClockMonth-April(4), wtWebCount6ClockMonth-May(5), wtWebCount6ClockMonth-June(6), wtWebCount6ClockMonth-July(7), wtWebCount6ClockMonth-August(8), wtWebCount6ClockMonth-September(9), wtWebCount6ClockMonth-October(10), wtWebCount6ClockMonth-November(11), wtWebCount6ClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebCount6DeviceClock 4 } wtWebCount6ClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebCount6DeviceClock 5 } -- wtWebCount6Network Group ------------------------ wtWebCount6IpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebCount6Network 1 } wtWebCount6SubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebCount6Network 2 } wtWebCount6Gateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebCount6Network 3 } wtWebCount6DnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebCount6Network 4 } wtWebCount6DnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebCount6Network 5 } wtWebCount6AddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebCount6Network 6 } -- wtWebCount6HTTP Group -------------------------------- wtWebCount6HttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebCount6HTTP 4 } -- wtWebCount6Mail Group -------------------------------- wtWebCount6MailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebCount6Mail 1 } wtWebCount6MailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebCount6Mail 2 } wtWebCount6MailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebCount6Mail 3 } wtWebCount6MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebCount6Mail 4 } wtWebCount6MailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebCount6Mail 5 } wtWebCount6MailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebCount6Mail 6 } wtWebCount6MailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebCount6Mail 7 } wtWebCount6MailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebCount6Mail 8 } -- wtWebCount6Snmp Group -------------------------------- wtWebCount6SnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebCount6SNMP 1 } wtWebCount6SnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebCount6SNMP 2 } wtWebCount6SnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebCount6SNMP 3 } wtWebCount6SnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebCount6SNMP 4 } wtWebCount6SnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtWebCount6SNMP 5 } -- wtWebCount6Udp Group -------------------------------- wtWebCount6UdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebCount6UDP 1 } wtWebCount6UdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebCount6UDP 2 } wtWebCount6UdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebCount6UDP 3 } -- wtWebCount6Syslog Group -------------------------------- wtWebCount6SyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebCount6Syslog 1 } wtWebCount6SyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebCount6Syslog 2 } wtWebCount6SyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebCount6Syslog 3 } wtWebCount6SyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebCount6Syslog 4 } -- wtWebCount6FTP Group -------------------------------- wtWebCount6FTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebCount6FTP 1 } wtWebCount6FTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebCount6FTP 2 } wtWebCount6FTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebCount6FTP 3 } wtWebCount6FTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebCount6FTP 4 } wtWebCount6FTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebCount6FTP 5 } wtWebCount6FTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebCount6FTP 6 } wtWebCount6FTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebCount6FTP 7 } -- wtWebCount6Report Group ---------------------------- wtWebCount6ReportCount OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent Reports." ::= { wtWebCount6Report 1 } -- Report Interface Table wtWebCount6ReportIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebCount6ReportIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of Report indices." ::= { wtWebCount6Report 2 } wtWebCount6ReportIfEntry OBJECT-TYPE SYNTAX WtWebCount6ReportIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the Reports." INDEX { wtWebCount6ReportNo } ::= { wtWebCount6ReportIfTable 1 } WtWebCount6ReportIfEntry ::= SEQUENCE { wtWebCount6ReportNo INTEGER } wtWebCount6ReportNo OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the Reports." ::= { wtWebCount6ReportIfEntry 1 } -- Report Table wtWebCount6ReportTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebCount6ReportEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the Report number." ::= { wtWebCount6Report 3 } wtWebCount6ReportEntry OBJECT-TYPE SYNTAX WtWebCount6ReportEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Report parameters of the individual Reports." INDEX { wtWebCount6ReportNo } ::= { wtWebCount6ReportTable 1 } WtWebCount6ReportEntry ::= SEQUENCE { wtWebCount6ReportInputTrigger OCTET STRING, wtWebCount6ReportSystemTrigger OCTET STRING, wtWebCount6ReportMaxCounterValue OCTET STRING, wtWebCount6ReportInterval OCTET STRING, wtWebCount6ReportEnable OCTET STRING, wtWebCount6ReportMailAddr OCTET STRING, wtWebCount6ReportMailSubject OCTET STRING, wtWebCount6ReportMailText OCTET STRING, wtWebCount6ReportSnmpManagerIP OCTET STRING, wtWebCount6ReportSnmpTrapText OCTET STRING, wtWebCount6ReportUdpIpAddr OCTET STRING, wtWebCount6ReportUdpPort INTEGER, wtWebCount6ReportUdpText OCTET STRING, wtWebCount6ReportTcpIpAddr OCTET STRING, wtWebCount6ReportTcpPort INTEGER, wtWebCount6ReportTcpText OCTET STRING, wtWebCount6ReportSyslogIpAddr OCTET STRING, wtWebCount6ReportSyslogPort INTEGER, wtWebCount6ReportSyslogText OCTET STRING, wtWebCount6ReportFtpDataPort OCTET STRING, wtWebCount6ReportFtpFileName OCTET STRING, wtWebCount6ReportFtpText OCTET STRING, wtWebCount6ReportFtpOption OCTET STRING, wtWebCount6ReportTimerCron OCTET STRING, wtWebCount6ReportName OCTET STRING, wtWebCount6ReportGlobalEnable OCTET STRING, wtWebCount6ReportCounterClear OCTET STRING, wtWebCount6ReportRateOfChange OCTET STRING, wtWebCount6ReportRateOfChangeWindow OCTET STRING, wtWebCount6ReportRateOfChange OCTET STRING, wtWebCount6ReportRateOfChangeMode OCTET STRING } wtWebCount6ReportInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3: unused OCTET 4, Bit 0-5: Mask for digital inputs 0-5 Bit 6-7: unused OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-5: Level of digital inputs 0-5 Bit 6-7: unused OCTETS 9-12 contain the counter bit (1=ON, 0=OFF). Inputs masked with the counter bit trigger an Report when the corresponding counter reaching the wtWebCount6ReportMaxCounterValue. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-5: Counter bits of digital inputs 0-5 Bit 6-7: unused." ::= { wtWebCount6ReportEntry 1 } wtWebCount6ReportSystemTrigger OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 7 : Timer OFF Bit 6 : Time Window Bit 5 : unused Bit 4 : unused Bit 3 : unused Bit 2 : unused Bit 1 : Timer Bit 0 : unused" ::= { wtWebCount6ReportEntry 3 } wtWebCount6ReportMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding Report is triggered. Input counters with its mask bit unset in wtWebCount6ReportInputTrigger are not considered." ::= { wtWebCount6ReportEntry 4 } wtWebCount6ReportInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for Report messages." ::= { wtWebCount6ReportEntry 5 } wtWebCount6ReportEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded Report enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Output Switch Enable Bit 1: Mail Enable Bit 2: SNMP Trap enable Bit 3: UDP enable Bit 4: unused Bit 5: TCP Client enable Bit 6: Syslog Messages enable Bit 7: FTP Client enable" ::= { wtWebCount6ReportEntry 6 } wtWebCount6ReportMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the Report mail to." ::= { wtWebCount6ReportEntry 7 } wtWebCount6ReportMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for Report mail." ::= { wtWebCount6ReportEntry 8 } wtWebCount6ReportMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Report mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebCount6ReportEntry 9 } wtWebCount6ReportSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebCount6ReportEntry 10 } wtWebCount6ReportSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebCount6ReportEntry 11 } wtWebCount6ReportUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebCount6ReportEntry 12 } wtWebCount6ReportUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebCount6ReportEntry 13 } wtWebCount6ReportUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebCount6ReportEntry 14 } wtWebCount6ReportTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebCount6ReportEntry 15 } wtWebCount6ReportTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebCount6ReportEntry 16 } wtWebCount6ReportTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebCount6ReportEntry 17 } wtWebCount6ReportSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebCount6ReportEntry 18 } wtWebCount6ReportSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebCount6ReportEntry 19 } wtWebCount6ReportSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebCount6ReportEntry 20 } wtWebCount6ReportFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebCount6ReportEntry 21 } wtWebCount6ReportFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebCount6ReportEntry 22 } wtWebCount6ReportFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebCount6ReportEntry 23 } wtWebCount6ReportFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebCount6ReportEntry 24 } wtWebCount6ReportTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a report, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebCount6ReportEntry 25 } wtWebCount6ReportName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Report." ::= { wtWebCount6ReportEntry 33 } wtWebCount6ReportGlobalEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded Report activation: Die OCTETS werden bitweise interpretiert. Bit 0 entspricht dem LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Report enable" ::= { wtWebCount6ReportEntry 34 } wtWebCount6ReportCounterClear OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Counter clear on Report send" ::= { wtWebCount6ReportEntry 35 } wtWebCount6ReportRateOfChange OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value within a time slot. If an input counter value exceeds this max. value, the corresponding Report is triggered. Input counters with its mask bit unset in wtWebCount6ReportInputTrigger are not considered. A value of Zero disable the tracing of rate of change." ::= { wtWebCount6ReportEntry 52 } wtWebCount6ReportRateOfChangeWindow OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures the time slot of wtWebCount6ReportRateOfChange. Input counters with its mask bit unset in wtWebCount6ReportInputTrigger are not considered. A value of Zero disable the tracing of rate of change." ::= { wtWebCount6ReportEntry 53 } wtWebCount6ReportRateOfChangeMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: Minimum mode: a report will be send if the count of pulses is lower than the given pulse count in wtWebCount6ReportRateOfChange. Maximum mode: a report will be send if the count of pulses is greater than the pulse count given in wtWebCount6ReportRateOfChange. The OCTETS are interpreted bit-by-bit, use only one bit at a time. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 2 : Maximum Mode Bit 1 : Minimum Mode Bit 0 : Rate of Change OFF" ::= { wtWebCount6ReportEntry 54 } -- wtWebCount6Ports Group ---------------------------- -- Input Port Table wtWebCount6InputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebCount6InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebCount6Ports 1 } wtWebCount6InputPortEntry OBJECT-TYPE SYNTAX WtWebCount6InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebCount6InputNo } ::= { wtWebCount6InputPortTable 1 } WtWebCount6InputPortEntry ::= SEQUENCE { wtWebCount6PortInputName OCTET STRING, wtWebCount6PortInputText OCTET STRING, wtWebCount6PortInputMode OCTET STRING, wtWebCount6PortInputFilter INTEGER, wtWebCount6PortInputPulsePolarity OCTET STRING, wtWebCount6PortInputBicountInactivTimeout INTEGER, wtWebCount6PortInputCounterSet INTEGER, wtWebCount6PortInputCounterScale OCTET STRING, wtWebCount6PortInputCounterUnit OCTET STRING } wtWebCount6PortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebCount6InputPortEntry 1 } wtWebCount6PortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebCount6InputPortEntry 2 } wtWebCount6PortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded modes: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. Selection for input 0-1: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Bidirectional counter enable Bit 2 : unused Bit 1 : Change detection enable Bit 0 : unused" ::= { wtWebCount6InputPortEntry 3 } wtWebCount6PortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebCount6InputPortEntry 4 } wtWebCount6PortInputPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebCount6InputPortEntry 5 } wtWebCount6PortInputBicountInactivTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored." ::= { wtWebCount6InputPortEntry 6 } wtWebCount6PortInputCounterSet OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Writing to this variable presets the counter, while reading returns the actual value." ::= { wtWebCount6InputPortEntry 7 } wtWebCount6PortInputCounterScale OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Conversion factor for this counter." ::= { wtWebCount6InputPortEntry 8 } wtWebCount6PortInputCounterUnit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Unit for this counter." ::= { wtWebCount6InputPortEntry 9 } -- wtWebCount6Manufact Group ---------------------------- wtWebCount6MfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebCount6Manufact 1 } wtWebCount6MfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebCount6Manufact 2 } wtWebCount6MfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebCount6Manufact 3 } wtWebCount6MfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebCount6Manufact 4 } wtWebCount6MfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebCount6Manufact 5 } wtWebCount6MfOrderNo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer part number." ::= { wtWebCount6Manufact 6 } -- wtWebCount6Diag Group ---------------------------- wtWebCount6DiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebCount6Diag 1 } wtWebCount6DiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebCount6Diag 2 } wtWebCount6DiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebCount6DiagErrorMessage. Errors are numbered from 1 to wtWebCount6DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebCount6DiagErrorMessage." ::= { wtWebCount6Diag 3 } wtWebCount6DiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebCount6DiagErrorIndex as an index, the appropriate message is available." ::= { wtWebCount6Diag 4 } wtWebCount6DiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebCount6Diag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Reporttriggerbedingungen zutreffen wtWebCount6Alert1 TRAP-TYPE ENTERPRISE wtWebCount6 VARIABLES { wtWebCount6ReportSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Report 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebCount Report 1" --#SUMMARY "Report 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtWebCount6Alert2 TRAP-TYPE ENTERPRISE wtWebCount6 VARIABLES { wtWebCount6ReportSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Report 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebCount Report 2" --#SUMMARY "Report 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtWebCount6Alert3 TRAP-TYPE ENTERPRISE wtWebCount6 VARIABLES { wtWebCount6ReportSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Report 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebCount Report 3" --#SUMMARY "Report 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtWebCount6Alert4 TRAP-TYPE ENTERPRISE wtWebCount6 VARIABLES { wtWebCount6ReportSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Report 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebCount Report 4" --#SUMMARY "Report 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtWebCount6Alert5 TRAP-TYPE ENTERPRISE wtWebCount6 VARIABLES { wtWebCount6ReportSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Report 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebCount Report 5" --#SUMMARY "Report 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtWebCount6Alert6 TRAP-TYPE ENTERPRISE wtWebCount6 VARIABLES { wtWebCount6ReportSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Report 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebCount Report 6" --#SUMMARY "Report 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtWebCount6Alert7 TRAP-TYPE ENTERPRISE wtWebCount6 VARIABLES { wtWebCount6ReportSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Report 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebCount Report 7" --#SUMMARY "Report 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtWebCount6Alert8 TRAP-TYPE ENTERPRISE wtWebCount6 VARIABLES { wtWebCount6ReportSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Report 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebCount Report 8" --#SUMMARY "Report 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtWebCount6Alert9 TRAP-TYPE ENTERPRISE wtWebCount6 VARIABLES { wtWebCount6ReportSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Report 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebCount Report 9" --#SUMMARY "Report 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtWebCount6Alert10 TRAP-TYPE ENTERPRISE wtWebCount6 VARIABLES { wtWebCount6ReportSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Report 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebCount Report 10" --#SUMMARY "Report 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtWebCount6Alert11 TRAP-TYPE ENTERPRISE wtWebCount6 VARIABLES { wtWebCount6ReportSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Report 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebCount Report 11" --#SUMMARY "Report 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtWebCount6Alert12 TRAP-TYPE ENTERPRISE wtWebCount6 VARIABLES { wtWebCount6ReportSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Report 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebCount Report 12" --#SUMMARY "Report 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtWebCount6AlertDiag TRAP-TYPE ENTERPRISE wtWebCount6 VARIABLES { wtWebCount6DiagErrorIndex, wtWebCount6DiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "WebCount Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebioEA6x6InOut Group ------------------------ wtWebioEA6x6Inputs OBJECT-TYPE SYNTAX INTEGER (1..6) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtWebioEA6x6InOut 1 } wtWebioEA6x6Outputs OBJECT-TYPE SYNTAX INTEGER (1..6) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent outputs." ::= { wtWebioEA6x6InOut 2 } -- Input Interface Table wtWebioEA6x6InputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA6x6InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebioEA6x6InOut 3 } wtWebioEA6x6InputEntry OBJECT-TYPE SYNTAX WtWebioEA6x6InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtWebioEA6x6InputNo } ::= { wtWebioEA6x6InputTable 1 } WtWebioEA6x6InputEntry ::= SEQUENCE { wtWebioEA6x6InputNo INTEGER, wtWebioEA6x6InputCounter INTEGER, wtWebioEA6x6InputCounterClear INTEGER, wtWebioEA6x6InputState INTEGER } wtWebioEA6x6InputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebioEA6x6InputEntry 1 } wtWebioEA6x6InputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebioEA6x6InputEntry 2 } wtWebioEA6x6InputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtWebioEA6x6InputEntry 3 } wtWebioEA6x6InputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of a single input bit, 0-OFF, 1-ON." ::= { wtWebioEA6x6InputEntry 4 } wtWebioEA6x6InputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, unused OCTET 4, Bit 0-5: Digital outputs 0-5 Bit 6-7: unused" ::= { wtWebioEA6x6InOut 4 } -- Output Interface Table wtWebioEA6x6OutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA6x6OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtWebioEA6x6InOut 5 } wtWebioEA6x6OutputEntry OBJECT-TYPE SYNTAX WtWebioEA6x6OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtWebioEA6x6OutputNo } ::= { wtWebioEA6x6OutputTable 1 } WtWebioEA6x6OutputEntry ::= SEQUENCE { wtWebioEA6x6OutputNo INTEGER, wtWebioEA6x6OutputState INTEGER } wtWebioEA6x6OutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtWebioEA6x6OutputEntry 1 } wtWebioEA6x6OutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of a single output bit, 0-OFF, 1-ON." ::= { wtWebioEA6x6OutputEntry 2 } wtWebioEA6x6OutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, unused OCTET 4, Bit 0-5: Digital outputs 0-5 Bit 6-7: unused" ::= { wtWebioEA6x6InOut 6 } wtWebioEA6x6SetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4 : Bit 0-5: Mask for digital outputs 0-5 Bit 6-7: unused OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8 : Bit 0-5: Level of digital outputs 0-5 Bit 6-7: unused" ::= { wtWebioEA6x6InOut 7 } -- wtWebioEA6x6SessCntrl Group -------------------------------- wtWebioEA6x6SessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebioEA6x6SessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebioEA6x6SessCntrl 1 } wtWebioEA6x6SessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebioEA6x6SessCntrl 2 } wtWebioEA6x6SessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebioEA6x6SessCntrl 3 } wtWebioEA6x6SessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebioEA6x6SessCntrl 4 } wtWebioEA6x6SessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebioEA6x6SessCntrl 5 } -- wtWebioEA6x6Text Group ------------------------ wtWebioEA6x6DeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebioEA6x6Text 1 } wtWebioEA6x6DeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebioEA6x6Text 2 } wtWebioEA6x6DeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebioEA6x6Text 3 } wtWebioEA6x6DeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebioEA6x6Text 4 } -- wtWebioEA6x6TimeZone Group ---------------------------- wtWebioEA6x6TzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebioEA6x6TimeZone 1 } wtWebioEA6x6TzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebioEA6x6TimeZone 2 } wtWebioEA6x6TzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebioEA6x6TimeZone 3 } wtWebioEA6x6StTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebioEA6x6TimeZone 4 } wtWebioEA6x6StTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebioEA6x6TimeZone 5 } wtWebioEA6x6StTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebioEA6x6TimeZone 6 } wtWebioEA6x6StTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA6x6StartMonth-January(1), wtWebioEA6x6StartMonth-February(2), wtWebioEA6x6StartMonth-March(3), wtWebioEA6x6StartMonth-April(4), wtWebioEA6x6StartMonth-May(5), wtWebioEA6x6StartMonth-June(6), wtWebioEA6x6StartMonth-July(7), wtWebioEA6x6StartMonth-August(8), wtWebioEA6x6StartMonth-September(9), wtWebioEA6x6StartMonth-October(10), wtWebioEA6x6StartMonth-November(11), wtWebioEA6x6StartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebioEA6x6TimeZone 7 } wtWebioEA6x6StTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA6x6StartMode-first(1), wtWebioEA6x6StartMode-second(2), wtWebioEA6x6StartMode-third(3), wtWebioEA6x6StartMode-fourth(4), wtWebioEA6x6StartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebioEA6x6TimeZone 8 } wtWebioEA6x6StTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA6x6StartWday-Sunday(1), wtWebioEA6x6StartWday-Monday(2), wtWebioEA6x6StartWday-Tuesday(3), wtWebioEA6x6StartWday-Thursday(4), wtWebioEA6x6StartWday-Wednesday(5), wtWebioEA6x6StartWday-Friday(6), wtWebioEA6x6StartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebioEA6x6TimeZone 9 } wtWebioEA6x6StTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA6x6TimeZone 10 } wtWebioEA6x6StTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA6x6TimeZone 11 } wtWebioEA6x6StTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA6x6StopMonth-January(1), wtWebioEA6x6StopMonth-February(2), wtWebioEA6x6StopMonth-March(3), wtWebioEA6x6StopMonth-April(4), wtWebioEA6x6StopMonth-May(5), wtWebioEA6x6StopMonth-June(6), wtWebioEA6x6StopMonth-July(7), wtWebioEA6x6StopMonth-August(8), wtWebioEA6x6StopMonth-September(9), wtWebioEA6x6StopMonth-October(10), wtWebioEA6x6StopMonth-November(11), wtWebioEA6x6StopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebioEA6x6TimeZone 12 } wtWebioEA6x6StTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA6x6StopMode-first(1), wtWebioEA6x6StopMode-second(2), wtWebioEA6x6StopMode-third(3), wtWebioEA6x6StopMode-fourth(4), wtWebioEA6x6StopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebioEA6x6TimeZone 13 } wtWebioEA6x6StTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA6x6StopWday-Sunday(1), wtWebioEA6x6StopWday-Monday(2), wtWebioEA6x6StopWday-Tuesday(3), wtWebioEA6x6StopWday-Thursday(4), wtWebioEA6x6StopWday-Wednesday(5), wtWebioEA6x6StopWday-Friday(6), wtWebioEA6x6StopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebioEA6x6TimeZone 14 } wtWebioEA6x6StTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA6x6TimeZone 15 } wtWebioEA6x6StTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA6x6TimeZone 16 } -- wtWebioEA6x6TimeServer Group ---------------------------- wtWebioEA6x6TimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebioEA6x6TimeServer 1 } wtWebioEA6x6TimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebioEA6x6TimeServer 2 } wtWebioEA6x6TsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebioEA6x6TimeServer 3 } wtWebioEA6x6TsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebioEA6x6TimeServer 4 } -- wtWebioEA6x6DeviceClock Group ---------------------------- wtWebioEA6x6ClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebioEA6x6DeviceClock 1 } wtWebioEA6x6ClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebioEA6x6DeviceClock 2 } wtWebioEA6x6ClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebioEA6x6DeviceClock 3 } wtWebioEA6x6ClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA6x6ClockMonth-January(1), wtWebioEA6x6ClockMonth-February(2), wtWebioEA6x6ClockMonth-March(3), wtWebioEA6x6ClockMonth-April(4), wtWebioEA6x6ClockMonth-May(5), wtWebioEA6x6ClockMonth-June(6), wtWebioEA6x6ClockMonth-July(7), wtWebioEA6x6ClockMonth-August(8), wtWebioEA6x6ClockMonth-September(9), wtWebioEA6x6ClockMonth-October(10), wtWebioEA6x6ClockMonth-November(11), wtWebioEA6x6ClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebioEA6x6DeviceClock 4 } wtWebioEA6x6ClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebioEA6x6DeviceClock 5 } -- wtWebioEA6x6Network Group ------------------------ wtWebioEA6x6IpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebioEA6x6Network 1 } wtWebioEA6x6SubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebioEA6x6Network 2 } wtWebioEA6x6Gateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebioEA6x6Network 3 } wtWebioEA6x6DnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebioEA6x6Network 4 } wtWebioEA6x6DnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebioEA6x6Network 5 } wtWebioEA6x6AddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebioEA6x6Network 6 } -- wtWebioEA6x6HTTP Group -------------------------------- wtWebioEA6x6Startup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebioEA6x6HTTP 1 } wtWebioEA6x6GetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebioEA6x6HTTP 2 } wtWebioEA6x6HttpInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-5: Digital inputs 0-5 Bit 6-7: unused" ::= { wtWebioEA6x6HTTP 3 } wtWebioEA6x6HttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebioEA6x6HTTP 4 } -- wtWebioEA6x6Mail Group -------------------------------- wtWebioEA6x6MailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebioEA6x6Mail 1 } wtWebioEA6x6MailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebioEA6x6Mail 2 } wtWebioEA6x6MailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebioEA6x6Mail 3 } wtWebioEA6x6MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebioEA6x6Mail 4 } wtWebioEA6x6MailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebioEA6x6Mail 5 } wtWebioEA6x6MailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebioEA6x6Mail 6 } wtWebioEA6x6MailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebioEA6x6Mail 7 } wtWebioEA6x6MailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebioEA6x6Mail 8 } -- wtWebioEA6x6Snmp Group -------------------------------- wtWebioEA6x6SnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebioEA6x6SNMP 1 } wtWebioEA6x6SnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebioEA6x6SNMP 2 } wtWebioEA6x6SnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebioEA6x6SNMP 3 } wtWebioEA6x6SnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebioEA6x6SNMP 4 } wtWebioEA6x6SnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtWebioEA6x6SNMP 5 } -- wtWebioEA6x6Udp Group -------------------------------- wtWebioEA6x6UdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebioEA6x6UDP 1 } wtWebioEA6x6UdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebioEA6x6UDP 2 } wtWebioEA6x6UdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebioEA6x6UDP 3 } -- wtWebioEA6x6Binary Group -------------------------------- wtWebioEA6x6BinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebioEA6x6Binary 1 } -- Binary Interface Table wtWebioEA6x6BinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA6x6BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebioEA6x6Binary 2 } wtWebioEA6x6BinaryIfEntry OBJECT-TYPE SYNTAX WtWebioEA6x6BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebioEA6x6BinaryModeNo } ::= { wtWebioEA6x6BinaryIfTable 1 } WtWebioEA6x6BinaryIfEntry ::= SEQUENCE { wtWebioEA6x6BinaryModeNo INTEGER } wtWebioEA6x6BinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebioEA6x6BinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebioEA6x6BinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA6x6BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebioEA6x6Binary 3 } wtWebioEA6x6BinaryEntry OBJECT-TYPE SYNTAX WtWebioEA6x6BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebioEA6x6BinaryModeNo } ::= { wtWebioEA6x6BinaryTable 1 } WtWebioEA6x6BinaryEntry ::= SEQUENCE { wtWebioEA6x6BinaryOperationMode OCTET STRING, wtWebioEA6x6BinaryTcpServerLocalPort INTEGER, wtWebioEA6x6BinaryTcpServerInputTrigger OCTET STRING, wtWebioEA6x6BinaryTcpServerApplicationMode OCTET STRING, wtWebioEA6x6BinaryTcpClientLocalPort INTEGER, wtWebioEA6x6BinaryTcpClientServerPort INTEGER, wtWebioEA6x6BinaryTcpClientServerIpAddr OCTET STRING, wtWebioEA6x6BinaryTcpClientServerPassword OCTET STRING, wtWebioEA6x6BinaryTcpClientInactivity INTEGER, wtWebioEA6x6BinaryTcpClientInputTrigger OCTET STRING, wtWebioEA6x6BinaryTcpClientInterval INTEGER, wtWebioEA6x6BinaryTcpClientApplicationMode OCTET STRING, wtWebioEA6x6BinaryUdpPeerLocalPort INTEGER, wtWebioEA6x6BinaryUdpPeerRemotePort INTEGER, wtWebioEA6x6BinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebioEA6x6BinaryUdpPeerInputTrigger OCTET STRING, wtWebioEA6x6BinaryUdpPeerInterval INTEGER, wtWebioEA6x6BinaryUdpPeerApplicationMode OCTET STRING, wtWebioEA6x6BinaryConnectedPort INTEGER, wtWebioEA6x6BinaryConnectedIpAddr IpAddress, wtWebioEA6x6BinaryTcpServerClientHttpPort INTEGER, wtWebioEA6x6BinaryTcpClientServerHttpPort INTEGER } wtWebioEA6x6BinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebioEA6x6BinaryEntry 1 } wtWebioEA6x6BinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA6x6BinaryEntry 2 } wtWebioEA6x6BinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-5: Digital inputs 0-5 Bit 6-7: unused" ::= { wtWebioEA6x6BinaryEntry 3 } wtWebioEA6x6BinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA6x6BinaryEntry 4 } wtWebioEA6x6BinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA6x6BinaryEntry 5 } wtWebioEA6x6BinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebioEA6x6BinaryEntry 6 } wtWebioEA6x6BinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebioEA6x6BinaryEntry 7 } wtWebioEA6x6BinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebioEA6x6BinaryEntry 8 } wtWebioEA6x6BinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebioEA6x6BinaryEntry 9 } wtWebioEA6x6BinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-5: Digital inputs 0-5 Bit 6-7: unused" ::= { wtWebioEA6x6BinaryEntry 10 } wtWebioEA6x6BinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebioEA6x6BinaryEntry 11 } wtWebioEA6x6BinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA6x6BinaryEntry 12 } wtWebioEA6x6BinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA6x6BinaryEntry 13 } wtWebioEA6x6BinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebioEA6x6BinaryEntry 14 } wtWebioEA6x6BinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebioEA6x6BinaryEntry 15 } wtWebioEA6x6BinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-5: Digital inputs 0-5 Bit 6-7: unused" ::= { wtWebioEA6x6BinaryEntry 16 } wtWebioEA6x6BinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebioEA6x6BinaryEntry 17 } wtWebioEA6x6BinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA6x6BinaryEntry 18 } wtWebioEA6x6BinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebioEA6x6BinaryEntry 19 } wtWebioEA6x6BinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebioEA6x6BinaryEntry 20 } wtWebioEA6x6BinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebioEA6x6BinaryEntry 21 } wtWebioEA6x6BinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebioEA6x6BinaryEntry 22 } -- wtWebioEA6x6Syslog Group -------------------------------- wtWebioEA6x6SyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebioEA6x6Syslog 1 } wtWebioEA6x6SyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebioEA6x6Syslog 2 } wtWebioEA6x6SyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebioEA6x6Syslog 3 } wtWebioEA6x6SyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebioEA6x6Syslog 4 } -- wtWebioEA6x6FTP Group -------------------------------- wtWebioEA6x6FTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebioEA6x6FTP 1 } wtWebioEA6x6FTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioEA6x6FTP 2 } wtWebioEA6x6FTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebioEA6x6FTP 3 } wtWebioEA6x6FTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebioEA6x6FTP 4 } wtWebioEA6x6FTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebioEA6x6FTP 5 } wtWebioEA6x6FTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebioEA6x6FTP 6 } wtWebioEA6x6FTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebioEA6x6FTP 7 } -- wtWebioEA6x6OutputMode Group -------------------------------- -- OutputMode Table wtWebioEA6x6OutputModeTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA6x6OutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of output mode configurations dependent on the output indices." ::= { wtWebioEA6x6OutputMode 1 } wtWebioEA6x6OutputModeEntry OBJECT-TYPE SYNTAX WtWebioEA6x6OutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output mode configurations of the individual outputs." INDEX { wtWebioEA6x6OutputNo } ::= { wtWebioEA6x6OutputModeTable 1 } WtWebioEA6x6OutputModeEntry ::= SEQUENCE { wtWebioEA6x6OutputModeBit OCTET STRING } wtWebioEA6x6OutputModeBit OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebioEA6x6OutputModeEntry 1 } wtWebioEA6x6SafetyTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined." ::= { wtWebioEA6x6OutputMode 2 } -- wtWebioEA6x6Alarm Group ---------------------------- wtWebioEA6x6AlarmCount OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebioEA6x6Alarm 1 } -- Alarm Interface Table wtWebioEA6x6AlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA6x6AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebioEA6x6Alarm 2 } wtWebioEA6x6AlarmIfEntry OBJECT-TYPE SYNTAX WtWebioEA6x6AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebioEA6x6AlarmNo } ::= { wtWebioEA6x6AlarmIfTable 1 } WtWebioEA6x6AlarmIfEntry ::= SEQUENCE { wtWebioEA6x6AlarmNo INTEGER } wtWebioEA6x6AlarmNo OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtWebioEA6x6AlarmIfEntry 1 } -- Alarm Table wtWebioEA6x6AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA6x6AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebioEA6x6Alarm 3 } wtWebioEA6x6AlarmEntry OBJECT-TYPE SYNTAX WtWebioEA6x6AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebioEA6x6AlarmNo } ::= { wtWebioEA6x6AlarmTable 1 } WtWebioEA6x6AlarmEntry ::= SEQUENCE { wtWebioEA6x6AlarmInputTrigger OCTET STRING, wtWebioEA6x6AlarmOutputTrigger OCTET STRING, wtWebioEA6x6AlarmSystemTrigger OCTET STRING, wtWebioEA6x6AlarmMaxCounterValue OCTET STRING, wtWebioEA6x6AlarmInterval OCTET STRING, wtWebioEA6x6AlarmEnable OCTET STRING, wtWebioEA6x6AlarmMailAddr OCTET STRING, wtWebioEA6x6AlarmMailSubject OCTET STRING, wtWebioEA6x6AlarmMailText OCTET STRING, wtWebioEA6x6AlarmSnmpManagerIP OCTET STRING, wtWebioEA6x6AlarmSnmpTrapText OCTET STRING, wtWebioEA6x6AlarmUdpIpAddr OCTET STRING, wtWebioEA6x6AlarmUdpPort INTEGER, wtWebioEA6x6AlarmUdpText OCTET STRING, wtWebioEA6x6AlarmTcpIpAddr OCTET STRING, wtWebioEA6x6AlarmTcpPort INTEGER, wtWebioEA6x6AlarmTcpText OCTET STRING, wtWebioEA6x6AlarmSyslogIpAddr OCTET STRING, wtWebioEA6x6AlarmSyslogPort INTEGER, wtWebioEA6x6AlarmSyslogText OCTET STRING, wtWebioEA6x6AlarmFtpDataPort OCTET STRING, wtWebioEA6x6AlarmFtpFileName OCTET STRING, wtWebioEA6x6AlarmFtpText OCTET STRING, wtWebioEA6x6AlarmFtpOption OCTET STRING, wtWebioEA6x6AlarmTimerCron OCTET STRING, wtWebioEA6x6AlarmMailReleaseSubject OCTET STRING, wtWebioEA6x6AlarmMailReleaseText OCTET STRING, wtWebioEA6x6AlarmSnmpTrapReleaseText OCTET STRING, wtWebioEA6x6AlarmUdpReleaseText OCTET STRING, wtWebioEA6x6AlarmTcpReleaseText OCTET STRING, wtWebioEA6x6AlarmSyslogReleaseText OCTET STRING, wtWebioEA6x6AlarmFtpReleaseText OCTET STRING } wtWebioEA6x6AlarmInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-5: Mask for digital inputs 0-5 Bit 6-7: unused OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-5: Level of digital inputs 0-5 Bit 6-7: unused OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-5: ANY bits of digital inputs 0-5 Bit 6-7: unused" ::= { wtWebioEA6x6AlarmEntry 1 } wtWebioEA6x6AlarmOutputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-5: Mask for digital outputs 0-5 Bit 6-7: unused OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-5: Level of digital outputs 0-5 Bit 6-7: unused OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-5: ANY bits of digital outputs 0-5 Bit 6-7: unused" ::= { wtWebioEA6x6AlarmEntry 2 } wtWebioEA6x6AlarmSystemTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control" ::= { wtWebioEA6x6AlarmEntry 3 } wtWebioEA6x6AlarmMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA6x6AlarmInputTrigger are not considered." ::= { wtWebioEA6x6AlarmEntry 4 } wtWebioEA6x6AlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebioEA6x6AlarmEntry 5 } wtWebioEA6x6AlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused" ::= { wtWebioEA6x6AlarmEntry 6 } wtWebioEA6x6AlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebioEA6x6AlarmEntry 7 } wtWebioEA6x6AlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA6x6AlarmEntry 8 } wtWebioEA6x6AlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA6x6AlarmEntry 9 } wtWebioEA6x6AlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebioEA6x6AlarmEntry 10 } wtWebioEA6x6AlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA6x6AlarmEntry 11 } wtWebioEA6x6AlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA6x6AlarmEntry 12 } wtWebioEA6x6AlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA6x6AlarmEntry 13 } wtWebioEA6x6AlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA6x6AlarmEntry 14 } wtWebioEA6x6AlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA6x6AlarmEntry 15 } wtWebioEA6x6AlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA6x6AlarmEntry 16 } wtWebioEA6x6AlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA6x6AlarmEntry 17 } wtWebioEA6x6AlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA6x6AlarmEntry 18 } wtWebioEA6x6AlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA6x6AlarmEntry 19 } wtWebioEA6x6AlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA6x6AlarmEntry 20 } wtWebioEA6x6AlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebioEA6x6AlarmEntry 21 } wtWebioEA6x6AlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebioEA6x6AlarmEntry 22 } wtWebioEA6x6AlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA6x6AlarmEntry 23 } wtWebioEA6x6AlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebioEA6x6AlarmEntry 24 } wtWebioEA6x6AlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebioEA6x6AlarmEntry 25 } wtWebioEA6x6AlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA6x6AlarmEntry 26 } wtWebioEA6x6AlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA6x6AlarmEntry 27 } wtWebioEA6x6AlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA6x6AlarmEntry 28 } wtWebioEA6x6AlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA6x6AlarmEntry 29 } wtWebioEA6x6AlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA6x6AlarmEntry 30 } wtWebioEA6x6AlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA6x6AlarmEntry 31 } wtWebioEA6x6AlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA6x6AlarmEntry 32 } -- wtWebioEA6x6Ports Group ---------------------------- -- Input Port Table wtWebioEA6x6InputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA6x6InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebioEA6x6Ports 1 } wtWebioEA6x6InputPortEntry OBJECT-TYPE SYNTAX WtWebioEA6x6InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebioEA6x6InputNo } ::= { wtWebioEA6x6InputPortTable 1 } WtWebioEA6x6InputPortEntry ::= SEQUENCE { wtWebioEA6x6PortInputName OCTET STRING, wtWebioEA6x6PortInputText OCTET STRING, wtWebioEA6x6PortInputMode OCTET STRING, wtWebioEA6x6PortInputFilter INTEGER, wtWebioEA6x6PortInputBicountPulsePolarity OCTET STRING, wtWebioEA6x6PortInputBicountInactivTimeout INTEGER } wtWebioEA6x6PortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebioEA6x6InputPortEntry 1 } wtWebioEA6x6PortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebioEA6x6InputPortEntry 2 } wtWebioEA6x6PortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an input. Bit 0 corresponds to the LSB. Selection for input 0-3: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 3-7: unused Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable Selection for inputs 4-5: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on read Bit 0 : Change detection enable (default)" ::= { wtWebioEA6x6InputPortEntry 3 } wtWebioEA6x6PortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebioEA6x6InputPortEntry 4 } wtWebioEA6x6PortInputBicountPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA6x6InputPortEntry 5 } wtWebioEA6x6PortInputBicountInactivTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored." ::= { wtWebioEA6x6InputPortEntry 6 } -- Output Port Table wtWebioEA6x6OutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA6x6OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtWebioEA6x6Ports 2 } wtWebioEA6x6OutputPortEntry OBJECT-TYPE SYNTAX WtWebioEA6x6OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtWebioEA6x6OutputNo } ::= { wtWebioEA6x6OutputPortTable 1 } WtWebioEA6x6OutputPortEntry ::= SEQUENCE { wtWebioEA6x6PortOutputName OCTET STRING, wtWebioEA6x6PortOutputText OCTET STRING, wtWebioEA6x6PortOutputGroupMode OCTET STRING, wtWebioEA6x6PortOutputSafetyState OCTET STRING, wtWebioEA6x6PortLogicInputMask OCTET STRING, wtWebioEA6x6PortLogicInputInverter OCTET STRING, wtWebioEA6x6PortLogicFunction OCTET STRING, wtWebioEA6x6PortLogicOutputInverter OCTET STRING, wtWebioEA6x6PortPulseDuration INTEGER, wtWebioEA6x6PortPulsePolarity OCTET STRING } wtWebioEA6x6PortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtWebioEA6x6OutputPortEntry 1 } wtWebioEA6x6PortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtWebioEA6x6OutputPortEntry 2 } wtWebioEA6x6PortOutputGroupMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one output bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for outputs 0-3: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 0,1,2,3 disconnected (default) Bit 1 : outputs 0+1, 2+3 connected Bit 2 : outputs 0+1+2+3 connected Bit 3-7 : unused Selection for outputs 4-7: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 4, 5 disconnected (default) Bit 1 : outputs 4+5 connected Bit 2-7 : unused Selection for outputs 8-11: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: unused" ::= { wtWebioEA6x6OutputPortEntry 3 } wtWebioEA6x6PortOutputSafetyState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output" ::= { wtWebioEA6x6OutputPortEntry 4 } wtWebioEA6x6PortLogicInputMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA6x6PortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA6x6PortLogicInputInverter) 3. Logical combination (wtWebioEA6x6PortLogicFunction) 4. Inverting the result if necessary (wtWebioEA6x6PortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-5 : inputs 0-5 Bit 6-7 : unused" ::= { wtWebioEA6x6OutputPortEntry 5 } wtWebioEA6x6PortLogicInputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-5 : inputs 0-5 Bit 6-7 : unused" ::= { wtWebioEA6x6OutputPortEntry 6 } wtWebioEA6x6PortLogicFunction OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused" ::= { wtWebioEA6x6OutputPortEntry 7 } wtWebioEA6x6PortLogicOutputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused" ::= { wtWebioEA6x6OutputPortEntry 8 } wtWebioEA6x6PortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtWebioEA6x6OutputPortEntry 9 } wtWebioEA6x6PortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtWebioEA6x6PortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA6x6OutputPortEntry 10 } -- wtWebioEA6x6Manufact Group ---------------------------- wtWebioEA6x6MfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebioEA6x6Manufact 1 } wtWebioEA6x6MfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebioEA6x6Manufact 2 } wtWebioEA6x6MfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebioEA6x6Manufact 3 } wtWebioEA6x6MfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebioEA6x6Manufact 4 } wtWebioEA6x6MfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebioEA6x6Manufact 5 } -- wtWebioEA6x6Diag Group ---------------------------- wtWebioEA6x6DiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebioEA6x6Diag 1 } wtWebioEA6x6DiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebioEA6x6Diag 2 } wtWebioEA6x6DiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebioEA6x6DiagErrorMessage. Errors are numbered from 1 to wtWebioEA6x6DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA6x6DiagErrorMessage." ::= { wtWebioEA6x6Diag 3 } wtWebioEA6x6DiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebioEA6x6DiagErrorIndex as an index, the appropriate message is available." ::= { wtWebioEA6x6Diag 4 } wtWebioEA6x6DiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebioEA6x6Diag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebioEA6x6Alert1 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtWebioEA6x6Alert2 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtWebioEA6x6Alert3 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtWebioEA6x6Alert4 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtWebioEA6x6Alert5 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtWebioEA6x6Alert6 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtWebioEA6x6Alert7 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtWebioEA6x6Alert8 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtWebioEA6x6Alert9 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtWebioEA6x6Alert10 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtWebioEA6x6Alert11 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtWebioEA6x6Alert12 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtWebioEA6x6Alert13 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebioEA6x6Alert14 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebioEA6x6Alert15 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebioEA6x6Alert16 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebioEA6x6Alert17 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebioEA6x6Alert18 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebioEA6x6Alert19 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebioEA6x6Alert20 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebioEA6x6Alert21 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtWebioEA6x6Alert22 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtWebioEA6x6Alert23 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebioEA6x6Alert24 TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebioEA6x6AlertDiag TRAP-TYPE ENTERPRISE wtWebioEA6x6 VARIABLES { wtWebioEA6x6DiagErrorIndex, wtWebioEA6x6DiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebioEA2x2ERPInOut Group ------------------------ wtWebioEA2x2ERPInputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtWebioEA2x2ERPInOut 1 } wtWebioEA2x2ERPOutputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent outputs." ::= { wtWebioEA2x2ERPInOut 2 } -- Input Interface Table wtWebioEA2x2ERPInputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERPInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebioEA2x2ERPInOut 3 } wtWebioEA2x2ERPInputEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERPInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtWebioEA2x2ERPInputNo } ::= { wtWebioEA2x2ERPInputTable 1 } WtWebioEA2x2ERPInputEntry ::= SEQUENCE { wtWebioEA2x2ERPInputNo INTEGER, wtWebioEA2x2ERPInputCounter INTEGER, wtWebioEA2x2ERPInputCounterClear INTEGER, wtWebioEA2x2ERPInputState INTEGER } wtWebioEA2x2ERPInputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebioEA2x2ERPInputEntry 1 } wtWebioEA2x2ERPInputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebioEA2x2ERPInputEntry 2 } wtWebioEA2x2ERPInputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtWebioEA2x2ERPInputEntry 3 } wtWebioEA2x2ERPInputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of a single input bit, 0-OFF, 1-ON." ::= { wtWebioEA2x2ERPInputEntry 4 } wtWebioEA2x2ERPInputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1" ::= { wtWebioEA2x2ERPInOut 4 } -- Output Interface Table wtWebioEA2x2ERPOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERPOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtWebioEA2x2ERPInOut 5 } wtWebioEA2x2ERPOutputEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERPOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtWebioEA2x2ERPOutputNo } ::= { wtWebioEA2x2ERPOutputTable 1 } WtWebioEA2x2ERPOutputEntry ::= SEQUENCE { wtWebioEA2x2ERPOutputNo INTEGER, wtWebioEA2x2ERPOutputState INTEGER } wtWebioEA2x2ERPOutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtWebioEA2x2ERPOutputEntry 1 } wtWebioEA2x2ERPOutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of a single output bit, 0-OFF, 1-ON." ::= { wtWebioEA2x2ERPOutputEntry 2 } wtWebioEA2x2ERPOutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt" ::= { wtWebioEA2x2ERPInOut 6 } wtWebioEA2x2ERPSetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1" ::= { wtWebioEA2x2ERPInOut 7 } -- wtWebioEA2x2ERPSessCntrl Group -------------------------------- wtWebioEA2x2ERPSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebioEA2x2ERPSessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebioEA2x2ERPSessCntrl 1 } wtWebioEA2x2ERPSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebioEA2x2ERPSessCntrl 2 } wtWebioEA2x2ERPSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebioEA2x2ERPSessCntrl 3 } wtWebioEA2x2ERPSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebioEA2x2ERPSessCntrl 4 } wtWebioEA2x2ERPSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebioEA2x2ERPSessCntrl 5 } -- wtWebioEA2x2ERPText Group ------------------------ wtWebioEA2x2ERPDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebioEA2x2ERPText 1 } wtWebioEA2x2ERPDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebioEA2x2ERPText 2 } wtWebioEA2x2ERPDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebioEA2x2ERPText 3 } wtWebioEA2x2ERPDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebioEA2x2ERPText 4 } -- wtWebioEA2x2ERPTimeZone Group ---------------------------- wtWebioEA2x2ERPTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebioEA2x2ERPTimeZone 1 } wtWebioEA2x2ERPTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebioEA2x2ERPTimeZone 2 } wtWebioEA2x2ERPTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebioEA2x2ERPTimeZone 3 } wtWebioEA2x2ERPStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebioEA2x2ERPTimeZone 4 } wtWebioEA2x2ERPStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebioEA2x2ERPTimeZone 5 } wtWebioEA2x2ERPStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebioEA2x2ERPTimeZone 6 } wtWebioEA2x2ERPStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ERPStartMonth-January(1), wtWebioEA2x2ERPStartMonth-February(2), wtWebioEA2x2ERPStartMonth-March(3), wtWebioEA2x2ERPStartMonth-April(4), wtWebioEA2x2ERPStartMonth-May(5), wtWebioEA2x2ERPStartMonth-June(6), wtWebioEA2x2ERPStartMonth-July(7), wtWebioEA2x2ERPStartMonth-August(8), wtWebioEA2x2ERPStartMonth-September(9), wtWebioEA2x2ERPStartMonth-October(10), wtWebioEA2x2ERPStartMonth-November(11), wtWebioEA2x2ERPStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebioEA2x2ERPTimeZone 7 } wtWebioEA2x2ERPStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ERPStartMode-first(1), wtWebioEA2x2ERPStartMode-second(2), wtWebioEA2x2ERPStartMode-third(3), wtWebioEA2x2ERPStartMode-fourth(4), wtWebioEA2x2ERPStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebioEA2x2ERPTimeZone 8 } wtWebioEA2x2ERPStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ERPStartWday-Sunday(1), wtWebioEA2x2ERPStartWday-Monday(2), wtWebioEA2x2ERPStartWday-Tuesday(3), wtWebioEA2x2ERPStartWday-Thursday(4), wtWebioEA2x2ERPStartWday-Wednesday(5), wtWebioEA2x2ERPStartWday-Friday(6), wtWebioEA2x2ERPStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebioEA2x2ERPTimeZone 9 } wtWebioEA2x2ERPStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA2x2ERPTimeZone 10 } wtWebioEA2x2ERPStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA2x2ERPTimeZone 11 } wtWebioEA2x2ERPStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ERPStopMonth-January(1), wtWebioEA2x2ERPStopMonth-February(2), wtWebioEA2x2ERPStopMonth-March(3), wtWebioEA2x2ERPStopMonth-April(4), wtWebioEA2x2ERPStopMonth-May(5), wtWebioEA2x2ERPStopMonth-June(6), wtWebioEA2x2ERPStopMonth-July(7), wtWebioEA2x2ERPStopMonth-August(8), wtWebioEA2x2ERPStopMonth-September(9), wtWebioEA2x2ERPStopMonth-October(10), wtWebioEA2x2ERPStopMonth-November(11), wtWebioEA2x2ERPStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebioEA2x2ERPTimeZone 12 } wtWebioEA2x2ERPStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ERPStopMode-first(1), wtWebioEA2x2ERPStopMode-second(2), wtWebioEA2x2ERPStopMode-third(3), wtWebioEA2x2ERPStopMode-fourth(4), wtWebioEA2x2ERPStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebioEA2x2ERPTimeZone 13 } wtWebioEA2x2ERPStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ERPStopWday-Sunday(1), wtWebioEA2x2ERPStopWday-Monday(2), wtWebioEA2x2ERPStopWday-Tuesday(3), wtWebioEA2x2ERPStopWday-Thursday(4), wtWebioEA2x2ERPStopWday-Wednesday(5), wtWebioEA2x2ERPStopWday-Friday(6), wtWebioEA2x2ERPStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebioEA2x2ERPTimeZone 14 } wtWebioEA2x2ERPStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA2x2ERPTimeZone 15 } wtWebioEA2x2ERPStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA2x2ERPTimeZone 16 } -- wtWebioEA2x2ERPTimeServer Group ---------------------------- wtWebioEA2x2ERPTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebioEA2x2ERPTimeServer 1 } wtWebioEA2x2ERPTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebioEA2x2ERPTimeServer 2 } wtWebioEA2x2ERPTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebioEA2x2ERPTimeServer 3 } wtWebioEA2x2ERPTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebioEA2x2ERPTimeServer 4 } -- wtWebioEA2x2ERPDeviceClock Group ---------------------------- wtWebioEA2x2ERPClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebioEA2x2ERPDeviceClock 1 } wtWebioEA2x2ERPClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebioEA2x2ERPDeviceClock 2 } wtWebioEA2x2ERPClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebioEA2x2ERPDeviceClock 3 } wtWebioEA2x2ERPClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ERPClockMonth-January(1), wtWebioEA2x2ERPClockMonth-February(2), wtWebioEA2x2ERPClockMonth-March(3), wtWebioEA2x2ERPClockMonth-April(4), wtWebioEA2x2ERPClockMonth-May(5), wtWebioEA2x2ERPClockMonth-June(6), wtWebioEA2x2ERPClockMonth-July(7), wtWebioEA2x2ERPClockMonth-August(8), wtWebioEA2x2ERPClockMonth-September(9), wtWebioEA2x2ERPClockMonth-October(10), wtWebioEA2x2ERPClockMonth-November(11), wtWebioEA2x2ERPClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebioEA2x2ERPDeviceClock 4 } wtWebioEA2x2ERPClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebioEA2x2ERPDeviceClock 5 } -- wtWebioEA2x2ERPNetwork Group ------------------------ wtWebioEA2x2ERPIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebioEA2x2ERPNetwork 1 } wtWebioEA2x2ERPSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebioEA2x2ERPNetwork 2 } wtWebioEA2x2ERPGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebioEA2x2ERPNetwork 3 } wtWebioEA2x2ERPDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebioEA2x2ERPNetwork 4 } wtWebioEA2x2ERPDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebioEA2x2ERPNetwork 5 } wtWebioEA2x2ERPAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebioEA2x2ERPNetwork 6 } -- wtWebioEA2x2ERPHTTP Group -------------------------------- wtWebioEA2x2ERPStartup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebioEA2x2ERPHTTP 1 } wtWebioEA2x2ERPGetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebioEA2x2ERPHTTP 2 } wtWebioEA2x2ERPHttpInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2ERPHTTP 3 } wtWebioEA2x2ERPHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebioEA2x2ERPHTTP 4 } -- wtWebioEA2x2ERPMail Group -------------------------------- wtWebioEA2x2ERPMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebioEA2x2ERPMail 1 } wtWebioEA2x2ERPMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebioEA2x2ERPMail 2 } wtWebioEA2x2ERPMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebioEA2x2ERPMail 3 } wtWebioEA2x2ERPMailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebioEA2x2ERPMail 4 } wtWebioEA2x2ERPMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebioEA2x2ERPMail 5 } wtWebioEA2x2ERPMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebioEA2x2ERPMail 6 } wtWebioEA2x2ERPMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebioEA2x2ERPMail 7 } wtWebioEA2x2ERPMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebioEA2x2ERPMail 8 } -- wtWebioEA2x2ERPSnmp Group -------------------------------- wtWebioEA2x2ERPSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebioEA2x2ERPSNMP 1 } wtWebioEA2x2ERPSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebioEA2x2ERPSNMP 2 } wtWebioEA2x2ERPSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebioEA2x2ERPSNMP 3 } wtWebioEA2x2ERPSnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebioEA2x2ERPSNMP 4 } wtWebioEA2x2ERPSnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtWebioEA2x2ERPSNMP 5 } -- wtWebioEA2x2ERPUDP Group -------------------------------- wtWebioEA2x2ERPUdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebioEA2x2ERPUDP 1 } wtWebioEA2x2ERPUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebioEA2x2ERPUDP 2 } wtWebioEA2x2ERPUdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebioEA2x2ERPUDP 3 } -- wtWebioEA2x2ERPBinary Group -------------------------------- wtWebioEA2x2ERPBinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebioEA2x2ERPBinary 1 } -- Binary Interface Table wtWebioEA2x2ERPBinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERPBinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebioEA2x2ERPBinary 2 } wtWebioEA2x2ERPBinaryIfEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERPBinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebioEA2x2ERPBinaryModeNo } ::= { wtWebioEA2x2ERPBinaryIfTable 1 } WtWebioEA2x2ERPBinaryIfEntry ::= SEQUENCE { wtWebioEA2x2ERPBinaryModeNo INTEGER } wtWebioEA2x2ERPBinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebioEA2x2ERPBinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebioEA2x2ERPBinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERPBinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebioEA2x2ERPBinary 3 } wtWebioEA2x2ERPBinaryEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERPBinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebioEA2x2ERPBinaryModeNo } ::= { wtWebioEA2x2ERPBinaryTable 1 } WtWebioEA2x2ERPBinaryEntry ::= SEQUENCE { wtWebioEA2x2ERPBinaryOperationMode OCTET STRING, wtWebioEA2x2ERPBinaryTcpServerLocalPort INTEGER, wtWebioEA2x2ERPBinaryTcpServerInputTrigger OCTET STRING, wtWebioEA2x2ERPBinaryTcpServerApplicationMode OCTET STRING, wtWebioEA2x2ERPBinaryTcpClientLocalPort INTEGER, wtWebioEA2x2ERPBinaryTcpClientServerPort INTEGER, wtWebioEA2x2ERPBinaryTcpClientServerIpAddr OCTET STRING, wtWebioEA2x2ERPBinaryTcpClientServerPassword OCTET STRING, wtWebioEA2x2ERPBinaryTcpClientInactivity INTEGER, wtWebioEA2x2ERPBinaryTcpClientInputTrigger OCTET STRING, wtWebioEA2x2ERPBinaryTcpClientInterval INTEGER, wtWebioEA2x2ERPBinaryTcpClientApplicationMode OCTET STRING, wtWebioEA2x2ERPBinaryUdpPeerLocalPort INTEGER, wtWebioEA2x2ERPBinaryUdpPeerRemotePort INTEGER, wtWebioEA2x2ERPBinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebioEA2x2ERPBinaryUdpPeerInputTrigger OCTET STRING, wtWebioEA2x2ERPBinaryUdpPeerInterval INTEGER, wtWebioEA2x2ERPBinaryUdpPeerApplicationMode OCTET STRING, wtWebioEA2x2ERPBinaryConnectedPort INTEGER, wtWebioEA2x2ERPBinaryConnectedIpAddr IpAddress, wtWebioEA2x2ERPBinaryTcpServerClientHttpPort INTEGER, wtWebioEA2x2ERPBinaryTcpClientServerHttpPort INTEGER } wtWebioEA2x2ERPBinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebioEA2x2ERPBinaryEntry 1 } wtWebioEA2x2ERPBinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA2x2ERPBinaryEntry 2 } wtWebioEA2x2ERPBinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2ERPBinaryEntry 3 } wtWebioEA2x2ERPBinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA2x2ERPBinaryEntry 4 } wtWebioEA2x2ERPBinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA2x2ERPBinaryEntry 5 } wtWebioEA2x2ERPBinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebioEA2x2ERPBinaryEntry 6 } wtWebioEA2x2ERPBinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebioEA2x2ERPBinaryEntry 7 } wtWebioEA2x2ERPBinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebioEA2x2ERPBinaryEntry 8 } wtWebioEA2x2ERPBinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebioEA2x2ERPBinaryEntry 9 } wtWebioEA2x2ERPBinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2ERPBinaryEntry 10 } wtWebioEA2x2ERPBinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebioEA2x2ERPBinaryEntry 11 } wtWebioEA2x2ERPBinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA2x2ERPBinaryEntry 12 } wtWebioEA2x2ERPBinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA2x2ERPBinaryEntry 13 } wtWebioEA2x2ERPBinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebioEA2x2ERPBinaryEntry 14 } wtWebioEA2x2ERPBinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebioEA2x2ERPBinaryEntry 15 } wtWebioEA2x2ERPBinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2ERPBinaryEntry 16 } wtWebioEA2x2ERPBinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebioEA2x2ERPBinaryEntry 17 } wtWebioEA2x2ERPBinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA2x2ERPBinaryEntry 18 } wtWebioEA2x2ERPBinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebioEA2x2ERPBinaryEntry 19 } wtWebioEA2x2ERPBinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebioEA2x2ERPBinaryEntry 20 } wtWebioEA2x2ERPBinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebioEA2x2ERPBinaryEntry 21 } wtWebioEA2x2ERPBinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebioEA2x2ERPBinaryEntry 22 } -- wtWebioEA2x2ERPSyslog Group -------------------------------- wtWebioEA2x2ERPSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebioEA2x2ERPSyslog 1 } wtWebioEA2x2ERPSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebioEA2x2ERPSyslog 2 } wtWebioEA2x2ERPSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebioEA2x2ERPSyslog 3 } wtWebioEA2x2ERPSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebioEA2x2ERPSyslog 4 } -- wtWebioEA2x2ERPFTP Group -------------------------------- wtWebioEA2x2ERPFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebioEA2x2ERPFTP 1 } wtWebioEA2x2ERPFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioEA2x2ERPFTP 2 } wtWebioEA2x2ERPFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebioEA2x2ERPFTP 3 } wtWebioEA2x2ERPFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebioEA2x2ERPFTP 4 } wtWebioEA2x2ERPFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebioEA2x2ERPFTP 5 } wtWebioEA2x2ERPFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebioEA2x2ERPFTP 6 } wtWebioEA2x2ERPFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebioEA2x2ERPFTP 7 } -- wtWebioEA2x2ERPWayBack Group -------------------------------- wtWebioEA2x2ERPWayBackEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable WayBack: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : WayBack enable" ::= { wtWebioEA2x2ERPWayBack 1 } wtWebioEA2x2ERPWayBackServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioEA2x2ERPWayBack 2 } wtWebioEA2x2ERPWayBackFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "WayBack FTP Loggin: Password of the user." ::= { wtWebioEA2x2ERPWayBack 3 } wtWebioEA2x2ERPWayBackFTPResponse OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "WayBack FTP response: return message after login." ::= { wtWebioEA2x2ERPWayBack 4 } wtWebioEA2x2ERPWayBackFTPTimeOut OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "WayBack FTP Timeout: a request must be finished within this periode of time." ::= { wtWebioEA2x2ERPWayBack 5 } -- wtWebioEA2x2ERPOutputMode Group -------------------------------- -- OutputMode Table wtWebioEA2x2ERPOutputModeTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERPOutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of output mode configurations dependent on the output indices." ::= { wtWebioEA2x2ERPOutputMode 1 } wtWebioEA2x2ERPOutputModeEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERPOutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output mode configurations of the individual outputs." INDEX { wtWebioEA2x2ERPOutputNo } ::= { wtWebioEA2x2ERPOutputModeTable 1 } WtWebioEA2x2ERPOutputModeEntry ::= SEQUENCE { wtWebioEA2x2ERPOutputModeBit OCTET STRING } wtWebioEA2x2ERPOutputModeBit OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebioEA2x2ERPOutputModeEntry 1 } wtWebioEA2x2ERPSafetyTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined." ::= { wtWebioEA2x2ERPOutputMode 2 } wtWebioEA2x2ERPLoadControlEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Here the function of automatic load control can be enabled. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Load Control enable" ::= { wtWebioEA2x2ERPOutputMode 3 } -- wtWebioEA2x2ERPAlarm Group ---------------------------- wtWebioEA2x2ERPAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebioEA2x2ERPAlarm 1 } -- Alarm Interface Table wtWebioEA2x2ERPAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERPAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebioEA2x2ERPAlarm 2 } wtWebioEA2x2ERPAlarmIfEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERPAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebioEA2x2ERPAlarmNo } ::= { wtWebioEA2x2ERPAlarmIfTable 1 } WtWebioEA2x2ERPAlarmIfEntry ::= SEQUENCE { wtWebioEA2x2ERPAlarmNo INTEGER } wtWebioEA2x2ERPAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtWebioEA2x2ERPAlarmIfEntry 1 } -- Alarm Table wtWebioEA2x2ERPAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERPAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebioEA2x2ERPAlarm 3 } wtWebioEA2x2ERPAlarmEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERPAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebioEA2x2ERPAlarmNo } ::= { wtWebioEA2x2ERPAlarmTable 1 } WtWebioEA2x2ERPAlarmEntry ::= SEQUENCE { wtWebioEA2x2ERPAlarmInputTrigger OCTET STRING, wtWebioEA2x2ERPAlarmOutputTrigger OCTET STRING, wtWebioEA2x2ERPAlarmSystemTrigger OCTET STRING, wtWebioEA2x2ERPAlarmMaxCounterValue OCTET STRING, wtWebioEA2x2ERPAlarmInterval OCTET STRING, wtWebioEA2x2ERPAlarmEnable OCTET STRING, wtWebioEA2x2ERPAlarmMailAddr OCTET STRING, wtWebioEA2x2ERPAlarmMailSubject OCTET STRING, wtWebioEA2x2ERPAlarmMailText OCTET STRING, wtWebioEA2x2ERPAlarmSnmpManagerIP OCTET STRING, wtWebioEA2x2ERPAlarmSnmpTrapText OCTET STRING, wtWebioEA2x2ERPAlarmUdpIpAddr OCTET STRING, wtWebioEA2x2ERPAlarmUdpPort INTEGER, wtWebioEA2x2ERPAlarmUdpText OCTET STRING, wtWebioEA2x2ERPAlarmTcpIpAddr OCTET STRING, wtWebioEA2x2ERPAlarmTcpPort INTEGER, wtWebioEA2x2ERPAlarmTcpText OCTET STRING, wtWebioEA2x2ERPAlarmSyslogIpAddr OCTET STRING, wtWebioEA2x2ERPAlarmSyslogPort INTEGER, wtWebioEA2x2ERPAlarmSyslogText OCTET STRING, wtWebioEA2x2ERPAlarmFtpDataPort OCTET STRING, wtWebioEA2x2ERPAlarmFtpFileName OCTET STRING, wtWebioEA2x2ERPAlarmFtpText OCTET STRING, wtWebioEA2x2ERPAlarmFtpOption OCTET STRING, wtWebioEA2x2ERPAlarmTimerCron OCTET STRING, wtWebioEA2x2ERPAlarmMailReleaseSubject OCTET STRING, wtWebioEA2x2ERPAlarmMailReleaseText OCTET STRING, wtWebioEA2x2ERPAlarmSnmpTrapReleaseText OCTET STRING, wtWebioEA2x2ERPAlarmUdpReleaseText OCTET STRING, wtWebioEA2x2ERPAlarmTcpReleaseText OCTET STRING, wtWebioEA2x2ERPAlarmSyslogReleaseText OCTET STRING, wtWebioEA2x2ERPAlarmFtpReleaseText OCTET STRING } wtWebioEA2x2ERPAlarmInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital inputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital inputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1" ::= { wtWebioEA2x2ERPAlarmEntry 1 } wtWebioEA2x2ERPAlarmOutputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1" ::= { wtWebioEA2x2ERPAlarmEntry 2 } wtWebioEA2x2ERPAlarmSystemTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control" ::= { wtWebioEA2x2ERPAlarmEntry 3 } wtWebioEA2x2ERPAlarmMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA2x2ERPAlarmInputTrigger are not considered." ::= { wtWebioEA2x2ERPAlarmEntry 4 } wtWebioEA2x2ERPAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebioEA2x2ERPAlarmEntry 5 } wtWebioEA2x2ERPAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused" ::= { wtWebioEA2x2ERPAlarmEntry 6 } wtWebioEA2x2ERPAlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebioEA2x2ERPAlarmEntry 7 } wtWebioEA2x2ERPAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA2x2ERPAlarmEntry 8 } wtWebioEA2x2ERPAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA2x2ERPAlarmEntry 9 } wtWebioEA2x2ERPAlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebioEA2x2ERPAlarmEntry 10 } wtWebioEA2x2ERPAlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA2x2ERPAlarmEntry 11 } wtWebioEA2x2ERPAlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA2x2ERPAlarmEntry 12 } wtWebioEA2x2ERPAlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA2x2ERPAlarmEntry 13 } wtWebioEA2x2ERPAlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA2x2ERPAlarmEntry 14 } wtWebioEA2x2ERPAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA2x2ERPAlarmEntry 15 } wtWebioEA2x2ERPAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA2x2ERPAlarmEntry 16 } wtWebioEA2x2ERPAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA2x2ERPAlarmEntry 17 } wtWebioEA2x2ERPAlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA2x2ERPAlarmEntry 18 } wtWebioEA2x2ERPAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA2x2ERPAlarmEntry 19 } wtWebioEA2x2ERPAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA2x2ERPAlarmEntry 20 } wtWebioEA2x2ERPAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebioEA2x2ERPAlarmEntry 21 } wtWebioEA2x2ERPAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebioEA2x2ERPAlarmEntry 22 } wtWebioEA2x2ERPAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA2x2ERPAlarmEntry 23 } wtWebioEA2x2ERPAlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebioEA2x2ERPAlarmEntry 24 } wtWebioEA2x2ERPAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebioEA2x2ERPAlarmEntry 25 } wtWebioEA2x2ERPAlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA2x2ERPAlarmEntry 26 } wtWebioEA2x2ERPAlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA2x2ERPAlarmEntry 27 } wtWebioEA2x2ERPAlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA2x2ERPAlarmEntry 28 } wtWebioEA2x2ERPAlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA2x2ERPAlarmEntry 29 } wtWebioEA2x2ERPAlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA2x2ERPAlarmEntry 30 } wtWebioEA2x2ERPAlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA2x2ERPAlarmEntry 31 } wtWebioEA2x2ERPAlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA2x2ERPAlarmEntry 32 } -- wtWebioEA2x2ERPLoadControl ---------------------------- wtWebioEA2x2ERPLoadControlView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Here the result of automatic load control can be read. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1." ::= { wtWebioEA2x2ERPAlarm 4 } wtWebioEA2x2ERPLCShutDownView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Here the result of the automatic load control shut down can be read. All outputs remain switched of, until a zero is written into this variable. But previously all loads should be inspected. High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason. If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair. All controlled output could be identified reading the variable wtWebioEA2x2ERPLoadControlEnable. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1." ::= { wtWebioEA2x2ERPAlarm 5 } -- wtWebioEA2x2ERPPorts Group ---------------------------- -- Input Port Table wtWebioEA2x2ERPInputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERPInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebioEA2x2ERPPorts 1 } wtWebioEA2x2ERPInputPortEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERPInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebioEA2x2ERPInputNo } ::= { wtWebioEA2x2ERPInputPortTable 1 } WtWebioEA2x2ERPInputPortEntry ::= SEQUENCE { wtWebioEA2x2ERPPortInputName OCTET STRING, wtWebioEA2x2ERPPortInputText OCTET STRING, wtWebioEA2x2ERPPortInputMode OCTET STRING, wtWebioEA2x2ERPPortInputFilter INTEGER, wtWebioEA2x2ERPPortInputBicountPulsePolarity OCTET STRING, wtWebioEA2x2ERPPortInputBicountInactivTimeout INTEGER } wtWebioEA2x2ERPPortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebioEA2x2ERPInputPortEntry 1 } wtWebioEA2x2ERPPortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebioEA2x2ERPInputPortEntry 2 } wtWebioEA2x2ERPPortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. Selection for input 0-1: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Bidirectional counter enable Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable" ::= { wtWebioEA2x2ERPInputPortEntry 3 } wtWebioEA2x2ERPPortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebioEA2x2ERPInputPortEntry 4 } wtWebioEA2x2ERPPortInputBicountPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA2x2ERPInputPortEntry 5 } wtWebioEA2x2ERPPortInputBicountInactivTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored." ::= { wtWebioEA2x2ERPInputPortEntry 6 } -- Output Port Table wtWebioEA2x2ERPOutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERPOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtWebioEA2x2ERPPorts 2 } wtWebioEA2x2ERPOutputPortEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERPOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtWebioEA2x2ERPOutputNo } ::= { wtWebioEA2x2ERPOutputPortTable 1 } WtWebioEA2x2ERPOutputPortEntry ::= SEQUENCE { wtWebioEA2x2ERPPortOutputName OCTET STRING, wtWebioEA2x2ERPPortOutputText OCTET STRING, wtWebioEA2x2ERPPortOutputGroupMode OCTET STRING, wtWebioEA2x2ERPPortOutputSafetyState OCTET STRING, wtWebioEA2x2ERPPortLogicInputMask OCTET STRING, wtWebioEA2x2ERPPortLogicInputInverter OCTET STRING, wtWebioEA2x2ERPPortLogicFunction OCTET STRING, wtWebioEA2x2ERPPortLogicOutputInverter OCTET STRING, wtWebioEA2x2ERPPortPulseDuration INTEGER, wtWebioEA2x2ERPPortPulsePolarity OCTET STRING } wtWebioEA2x2ERPPortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtWebioEA2x2ERPOutputPortEntry 1 } wtWebioEA2x2ERPPortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtWebioEA2x2ERPOutputPortEntry 2 } wtWebioEA2x2ERPPortOutputGroupMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one ouput bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for ouputs 0-1: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : ouputs 0,1 disconnected (default) Bit 1 : ouputs 0+1 connected" ::= { wtWebioEA2x2ERPOutputPortEntry 3 } wtWebioEA2x2ERPPortOutputSafetyState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output" ::= { wtWebioEA2x2ERPOutputPortEntry 4 } wtWebioEA2x2ERPPortLogicInputMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA2x2ERPPortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA2x2ERPPortLogicInputInverter) 3. Logical combination (wtWebioEA2x2ERPPortLogicFunction) 4. Inverting the result if necessary (wtWebioEA2x2ERPPortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1" ::= { wtWebioEA2x2ERPOutputPortEntry 5 } wtWebioEA2x2ERPPortLogicInputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1" ::= { wtWebioEA2x2ERPOutputPortEntry 6 } wtWebioEA2x2ERPPortLogicFunction OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused" ::= { wtWebioEA2x2ERPOutputPortEntry 7 } wtWebioEA2x2ERPPortLogicOutputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused" ::= { wtWebioEA2x2ERPOutputPortEntry 8 } wtWebioEA2x2ERPPortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtWebioEA2x2ERPOutputPortEntry 9 } wtWebioEA2x2ERPPortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtWebioEA2x2ERPPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA2x2ERPOutputPortEntry 10 } -- wtWebioEA2x2ERPManufact Group ---------------------------- wtWebioEA2x2ERPMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebioEA2x2ERPManufact 1 } wtWebioEA2x2ERPMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebioEA2x2ERPManufact 2 } wtWebioEA2x2ERPMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebioEA2x2ERPManufact 3 } wtWebioEA2x2ERPMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebioEA2x2ERPManufact 4 } wtWebioEA2x2ERPMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebioEA2x2ERPManufact 5 } -- wtWebioEA2x2ERPDiag Group ---------------------------- wtWebioEA2x2ERPDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebioEA2x2ERPDiag 1 } wtWebioEA2x2ERPDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebioEA2x2ERPDiag 2 } wtWebioEA2x2ERPDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebioEA2x2ERPDiagErrorMessage. Errors are numbered from 1 to wtWebioEA2x2ERPDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA2x2ERPDiagErrorMessage." ::= { wtWebioEA2x2ERPDiag 3 } wtWebioEA2x2ERPDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebioEA2x2ERPDiagErrorIndex as an index, the appropriate message is available." ::= { wtWebioEA2x2ERPDiag 4 } wtWebioEA2x2ERPDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebioEA2x2ERPDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebioEA2x2ERPAlert1 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtWebioEA2x2ERPAlert2 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtWebioEA2x2ERPAlert3 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtWebioEA2x2ERPAlert4 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtWebioEA2x2ERPAlert5 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtWebioEA2x2ERPAlert6 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtWebioEA2x2ERPAlert7 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtWebioEA2x2ERPAlert8 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtWebioEA2x2ERPAlert9 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtWebioEA2x2ERPAlert10 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtWebioEA2x2ERPAlert11 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtWebioEA2x2ERPAlert12 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtWebioEA2x2ERPAlert13 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebioEA2x2ERPAlert14 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebioEA2x2ERPAlert15 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebioEA2x2ERPAlert16 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebioEA2x2ERPAlert17 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebioEA2x2ERPAlert18 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebioEA2x2ERPAlert19 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebioEA2x2ERPAlert20 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebioEA2x2ERPAlert21 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtWebioEA2x2ERPAlert22 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtWebioEA2x2ERPAlert23 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebioEA2x2ERPAlert24 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebioEA2x2ERPAlertDiag TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP VARIABLES { wtWebioEA2x2ERPDiagErrorIndex, wtWebioEA2x2ERPDiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebioEA12x6RelERPInOut Group ------------------------ wtWebioEA12x6RelERPInputs OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtWebioEA12x6RelERPInOut 1 } wtWebioEA12x6RelERPOutputs OBJECT-TYPE SYNTAX INTEGER (1..6) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent outputs." ::= { wtWebioEA12x6RelERPInOut 2 } -- Input Interface Table wtWebioEA12x6RelERPInputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelERPInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebioEA12x6RelERPInOut 3 } wtWebioEA12x6RelERPInputEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelERPInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtWebioEA12x6RelERPInputNo } ::= { wtWebioEA12x6RelERPInputTable 1 } WtWebioEA12x6RelERPInputEntry ::= SEQUENCE { wtWebioEA12x6RelERPInputNo INTEGER, wtWebioEA12x6RelERPInputCounter INTEGER, wtWebioEA12x6RelERPInputCounterClear INTEGER } wtWebioEA12x6RelERPInputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebioEA12x6RelERPInputEntry 1 } wtWebioEA12x6RelERPInputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebioEA12x6RelERPInputEntry 2 } wtWebioEA12x6RelERPInputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtWebioEA12x6RelERPInputEntry 3 } wtWebioEA12x6RelERPInputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebioEA12x6RelERPInOut 4 } -- Output Interface Table wtWebioEA12x6RelERPOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelERPOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtWebioEA12x6RelERPInOut 5 } wtWebioEA12x6RelERPOutputEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelERPOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtWebioEA12x6RelERPOutputNo } ::= { wtWebioEA12x6RelERPOutputTable 1 } WtWebioEA12x6RelERPOutputEntry ::= SEQUENCE { wtWebioEA12x6RelERPOutputNo INTEGER, wtWebioEA12x6RelERPOutputState INTEGER } wtWebioEA12x6RelERPOutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtWebioEA12x6RelERPOutputEntry 1 } wtWebioEA12x6RelERPOutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Setting and reading of the states of the outputs, 0-OFF, 1-ON." ::= { wtWebioEA12x6RelERPOutputEntry 2 } wtWebioEA12x6RelERPOutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-5: Digital outputs 0-5" ::= { wtWebioEA12x6RelERPInOut 6 } wtWebioEA12x6RelERPSetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4 : Bit 0-5: Mask for digital outputs 0-5 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8 : Bit 0-5: Level of digital outputs 0-5" ::= { wtWebioEA12x6RelERPInOut 7 } -- wtWebioEA12x6RelERPSessCntrl Group -------------------------------- wtWebioEA12x6RelERPSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebioEA12x6RelERPSessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebioEA12x6RelERPSessCntrl 1 } wtWebioEA12x6RelERPSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebioEA12x6RelERPSessCntrl 2 } wtWebioEA12x6RelERPSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebioEA12x6RelERPSessCntrl 3 } wtWebioEA12x6RelERPSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebioEA12x6RelERPSessCntrl 4 } wtWebioEA12x6RelERPSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebioEA12x6RelERPSessCntrl 5 } -- wtWebioEA12x6RelERPText Group ------------------------ wtWebioEA12x6RelERPDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebioEA12x6RelERPText 1 } wtWebioEA12x6RelERPDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebioEA12x6RelERPText 2 } wtWebioEA12x6RelERPDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebioEA12x6RelERPText 3 } wtWebioEA12x6RelERPDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebioEA12x6RelERPText 4 } -- wtWebioEA12x6RelERPTimeZone Group ---------------------------- wtWebioEA12x6RelERPTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebioEA12x6RelERPTimeZone 1 } wtWebioEA12x6RelERPTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebioEA12x6RelERPTimeZone 2 } wtWebioEA12x6RelERPTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebioEA12x6RelERPTimeZone 3 } wtWebioEA12x6RelERPStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebioEA12x6RelERPTimeZone 4 } wtWebioEA12x6RelERPStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebioEA12x6RelERPTimeZone 5 } wtWebioEA12x6RelERPStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebioEA12x6RelERPTimeZone 6 } wtWebioEA12x6RelERPStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x6RelERPStartMonth-January(1), wtWebioEA12x6RelERPStartMonth-February(2), wtWebioEA12x6RelERPStartMonth-March(3), wtWebioEA12x6RelERPStartMonth-April(4), wtWebioEA12x6RelERPStartMonth-May(5), wtWebioEA12x6RelERPStartMonth-June(6), wtWebioEA12x6RelERPStartMonth-July(7), wtWebioEA12x6RelERPStartMonth-August(8), wtWebioEA12x6RelERPStartMonth-September(9), wtWebioEA12x6RelERPStartMonth-October(10), wtWebioEA12x6RelERPStartMonth-November(11), wtWebioEA12x6RelERPStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebioEA12x6RelERPTimeZone 7 } wtWebioEA12x6RelERPStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x6RelERPStartMode-first(1), wtWebioEA12x6RelERPStartMode-second(2), wtWebioEA12x6RelERPStartMode-third(3), wtWebioEA12x6RelERPStartMode-fourth(4), wtWebioEA12x6RelERPStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebioEA12x6RelERPTimeZone 8 } wtWebioEA12x6RelERPStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x6RelERPStartWday-Sunday(1), wtWebioEA12x6RelERPStartWday-Monday(2), wtWebioEA12x6RelERPStartWday-Tuesday(3), wtWebioEA12x6RelERPStartWday-Thursday(4), wtWebioEA12x6RelERPStartWday-Wednesday(5), wtWebioEA12x6RelERPStartWday-Friday(6), wtWebioEA12x6RelERPStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebioEA12x6RelERPTimeZone 9 } wtWebioEA12x6RelERPStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA12x6RelERPTimeZone 10 } wtWebioEA12x6RelERPStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA12x6RelERPTimeZone 11 } wtWebioEA12x6RelERPStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x6RelERPStopMonth-January(1), wtWebioEA12x6RelERPStopMonth-February(2), wtWebioEA12x6RelERPStopMonth-March(3), wtWebioEA12x6RelERPStopMonth-April(4), wtWebioEA12x6RelERPStopMonth-May(5), wtWebioEA12x6RelERPStopMonth-June(6), wtWebioEA12x6RelERPStopMonth-July(7), wtWebioEA12x6RelERPStopMonth-August(8), wtWebioEA12x6RelERPStopMonth-September(9), wtWebioEA12x6RelERPStopMonth-October(10), wtWebioEA12x6RelERPStopMonth-November(11), wtWebioEA12x6RelERPStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebioEA12x6RelERPTimeZone 12 } wtWebioEA12x6RelERPStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x6RelERPStopMode-first(1), wtWebioEA12x6RelERPStopMode-second(2), wtWebioEA12x6RelERPStopMode-third(3), wtWebioEA12x6RelERPStopMode-fourth(4), wtWebioEA12x6RelERPStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebioEA12x6RelERPTimeZone 13 } wtWebioEA12x6RelERPStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x6RelERPStopWday-Sunday(1), wtWebioEA12x6RelERPStopWday-Monday(2), wtWebioEA12x6RelERPStopWday-Tuesday(3), wtWebioEA12x6RelERPStopWday-Thursday(4), wtWebioEA12x6RelERPStopWday-Wednesday(5), wtWebioEA12x6RelERPStopWday-Friday(6), wtWebioEA12x6RelERPStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebioEA12x6RelERPTimeZone 14 } wtWebioEA12x6RelERPStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA12x6RelERPTimeZone 15 } wtWebioEA12x6RelERPStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA12x6RelERPTimeZone 16 } -- wtWebioEA12x6RelERPTimeServer Group ---------------------------- wtWebioEA12x6RelERPTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebioEA12x6RelERPTimeServer 1 } wtWebioEA12x6RelERPTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebioEA12x6RelERPTimeServer 2 } wtWebioEA12x6RelERPTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebioEA12x6RelERPTimeServer 3 } wtWebioEA12x6RelERPTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebioEA12x6RelERPTimeServer 4 } -- wtWebioEA12x6RelERPDeviceClock Group ---------------------------- wtWebioEA12x6RelERPClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebioEA12x6RelERPDeviceClock 1 } wtWebioEA12x6RelERPClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebioEA12x6RelERPDeviceClock 2 } wtWebioEA12x6RelERPClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebioEA12x6RelERPDeviceClock 3 } wtWebioEA12x6RelERPClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA12x6RelERPClockMonth-January(1), wtWebioEA12x6RelERPClockMonth-February(2), wtWebioEA12x6RelERPClockMonth-March(3), wtWebioEA12x6RelERPClockMonth-April(4), wtWebioEA12x6RelERPClockMonth-May(5), wtWebioEA12x6RelERPClockMonth-June(6), wtWebioEA12x6RelERPClockMonth-July(7), wtWebioEA12x6RelERPClockMonth-August(8), wtWebioEA12x6RelERPClockMonth-September(9), wtWebioEA12x6RelERPClockMonth-October(10), wtWebioEA12x6RelERPClockMonth-November(11), wtWebioEA12x6RelERPClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebioEA12x6RelERPDeviceClock 4 } wtWebioEA12x6RelERPClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebioEA12x6RelERPDeviceClock 5 } -- wtWebioEA12x6RelERPNetwork Group ------------------------ wtWebioEA12x6RelERPIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebioEA12x6RelERPNetwork 1 } wtWebioEA12x6RelERPSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebioEA12x6RelERPNetwork 2 } wtWebioEA12x6RelERPGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebioEA12x6RelERPNetwork 3 } wtWebioEA12x6RelERPDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebioEA12x6RelERPNetwork 4 } wtWebioEA12x6RelERPDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebioEA12x6RelERPNetwork 5 } wtWebioEA12x6RelERPAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebioEA12x6RelERPNetwork 6 } -- wtWebioEA12x6RelERPHTTP Group -------------------------------- wtWebioEA12x6RelERPStartup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebioEA12x6RelERPHTTP 1 } wtWebioEA12x6RelERPGetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebioEA12x6RelERPHTTP 2 } wtWebioEA12x6RelERPHttpInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebioEA12x6RelERPHTTP 3 } wtWebioEA12x6RelERPHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebioEA12x6RelERPHTTP 4 } -- wtWebioEA12x6RelERPMail Group -------------------------------- wtWebioEA12x6RelERPMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebioEA12x6RelERPMail 1 } wtWebioEA12x6RelERPMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebioEA12x6RelERPMail 2 } wtWebioEA12x6RelERPMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebioEA12x6RelERPMail 3 } wtWebioEA12x6RelERPMailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebioEA12x6RelERPMail 4 } wtWebioEA12x6RelERPMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebioEA12x6RelERPMail 5 } wtWebioEA12x6RelERPMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebioEA12x6RelERPMail 6 } wtWebioEA12x6RelERPMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebioEA12x6RelERPMail 7 } wtWebioEA12x6RelERPMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebioEA12x6RelERPMail 8 } -- wtWebioEA12x6RelERPSnmp Group -------------------------------- wtWebioEA12x6RelERPSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebioEA12x6RelERPSNMP 1 } wtWebioEA12x6RelERPSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebioEA12x6RelERPSNMP 2 } wtWebioEA12x6RelERPSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebioEA12x6RelERPSNMP 3 } wtWebioEA12x6RelERPSnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebioEA12x6RelERPSNMP 4 } wtWebioEA12x6RelERPSnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtWebioEA12x6RelERPSNMP 5 } -- wtWebioEA12x6RelERPUdp Group -------------------------------- wtWebioEA12x6RelERPUdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebioEA12x6RelERPUDP 1 } wtWebioEA12x6RelERPUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebioEA12x6RelERPUDP 2 } wtWebioEA12x6RelERPUdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebioEA12x6RelERPUDP 3 } -- wtWebioEA12x6RelERPBinary Group -------------------------------- wtWebioEA12x6RelERPBinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebioEA12x6RelERPBinary 1 } -- Binary Interface Table wtWebioEA12x6RelERPBinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelERPBinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebioEA12x6RelERPBinary 2 } wtWebioEA12x6RelERPBinaryIfEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelERPBinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebioEA12x6RelERPBinaryModeNo } ::= { wtWebioEA12x6RelERPBinaryIfTable 1 } WtWebioEA12x6RelERPBinaryIfEntry ::= SEQUENCE { wtWebioEA12x6RelERPBinaryModeNo INTEGER } wtWebioEA12x6RelERPBinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebioEA12x6RelERPBinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebioEA12x6RelERPBinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelERPBinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebioEA12x6RelERPBinary 3 } wtWebioEA12x6RelERPBinaryEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelERPBinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebioEA12x6RelERPBinaryModeNo } ::= { wtWebioEA12x6RelERPBinaryTable 1 } WtWebioEA12x6RelERPBinaryEntry ::= SEQUENCE { wtWebioEA12x6RelERPBinaryOperationMode OCTET STRING, wtWebioEA12x6RelERPBinaryTcpServerLocalPort INTEGER, wtWebioEA12x6RelERPBinaryTcpServerInputTrigger OCTET STRING, wtWebioEA12x6RelERPBinaryTcpServerApplicationMode OCTET STRING, wtWebioEA12x6RelERPBinaryTcpClientLocalPort INTEGER, wtWebioEA12x6RelERPBinaryTcpClientServerPort INTEGER, wtWebioEA12x6RelERPBinaryTcpClientServerIpAddr OCTET STRING, wtWebioEA12x6RelERPBinaryTcpClientServerPassword OCTET STRING, wtWebioEA12x6RelERPBinaryTcpClientInactivity INTEGER, wtWebioEA12x6RelERPBinaryTcpClientInputTrigger OCTET STRING, wtWebioEA12x6RelERPBinaryTcpClientInterval INTEGER, wtWebioEA12x6RelERPBinaryTcpClientApplicationMode OCTET STRING, wtWebioEA12x6RelERPBinaryUdpPeerLocalPort INTEGER, wtWebioEA12x6RelERPBinaryUdpPeerRemotePort INTEGER, wtWebioEA12x6RelERPBinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebioEA12x6RelERPBinaryUdpPeerInputTrigger OCTET STRING, wtWebioEA12x6RelERPBinaryUdpPeerInterval INTEGER, wtWebioEA12x6RelERPBinaryUdpPeerApplicationMode OCTET STRING, wtWebioEA12x6RelERPBinaryConnectedPort INTEGER, wtWebioEA12x6RelERPBinaryConnectedIpAddr IpAddress, wtWebioEA12x6RelERPBinaryTcpServerClientHttpPort INTEGER, wtWebioEA12x6RelERPBinaryTcpClientServerHttpPort INTEGER } wtWebioEA12x6RelERPBinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebioEA12x6RelERPBinaryEntry 1 } wtWebioEA12x6RelERPBinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA12x6RelERPBinaryEntry 2 } wtWebioEA12x6RelERPBinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebioEA12x6RelERPBinaryEntry 3 } wtWebioEA12x6RelERPBinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA12x6RelERPBinaryEntry 4 } wtWebioEA12x6RelERPBinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA12x6RelERPBinaryEntry 5 } wtWebioEA12x6RelERPBinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebioEA12x6RelERPBinaryEntry 6 } wtWebioEA12x6RelERPBinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebioEA12x6RelERPBinaryEntry 7 } wtWebioEA12x6RelERPBinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebioEA12x6RelERPBinaryEntry 8 } wtWebioEA12x6RelERPBinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebioEA12x6RelERPBinaryEntry 9 } wtWebioEA12x6RelERPBinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebioEA12x6RelERPBinaryEntry 10 } wtWebioEA12x6RelERPBinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebioEA12x6RelERPBinaryEntry 11 } wtWebioEA12x6RelERPBinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA12x6RelERPBinaryEntry 12 } wtWebioEA12x6RelERPBinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA12x6RelERPBinaryEntry 13 } wtWebioEA12x6RelERPBinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebioEA12x6RelERPBinaryEntry 14 } wtWebioEA12x6RelERPBinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebioEA12x6RelERPBinaryEntry 15 } wtWebioEA12x6RelERPBinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7" ::= { wtWebioEA12x6RelERPBinaryEntry 16 } wtWebioEA12x6RelERPBinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebioEA12x6RelERPBinaryEntry 17 } wtWebioEA12x6RelERPBinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA12x6RelERPBinaryEntry 18 } wtWebioEA12x6RelERPBinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebioEA12x6RelERPBinaryEntry 19 } wtWebioEA12x6RelERPBinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebioEA12x6RelERPBinaryEntry 20 } wtWebioEA12x6RelERPBinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebioEA12x6RelERPBinaryEntry 21 } wtWebioEA12x6RelERPBinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebioEA12x6RelERPBinaryEntry 22 } -- wtWebioEA12x6RelERPSyslog Group -------------------------------- wtWebioEA12x6RelERPSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebioEA12x6RelERPSyslog 1 } wtWebioEA12x6RelERPSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebioEA12x6RelERPSyslog 2 } wtWebioEA12x6RelERPSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebioEA12x6RelERPSyslog 3 } wtWebioEA12x6RelERPSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebioEA12x6RelERPSyslog 4 } -- wtWebioEA12x6RelERPFTP Group -------------------------------- wtWebioEA12x6RelERPFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebioEA12x6RelERPFTP 1 } wtWebioEA12x6RelERPFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioEA12x6RelERPFTP 2 } wtWebioEA12x6RelERPFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebioEA12x6RelERPFTP 3 } wtWebioEA12x6RelERPFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebioEA12x6RelERPFTP 4 } wtWebioEA12x6RelERPFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebioEA12x6RelERPFTP 5 } wtWebioEA12x6RelERPFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebioEA12x6RelERPFTP 6 } wtWebioEA12x6RelERPFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebioEA12x6RelERPFTP 7 } -- wtWebioEA12x6RelERPWayBack Group -------------------------------- wtWebioEA12x6RelERPWayBackEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable WayBack: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : WayBack enable" ::= { wtWebioEA12x6RelERPWayBack 1 } wtWebioEA12x6RelERPWayBackServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioEA12x6RelERPWayBack 2 } wtWebioEA12x6RelERPWayBackFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "WayBack FTP Loggin: Password of the user." ::= { wtWebioEA12x6RelERPWayBack 3 } wtWebioEA12x6RelERPWayBackFTPResponse OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "WayBack FTP response: return message after login." ::= { wtWebioEA12x6RelERPWayBack 4 } wtWebioEA12x6RelERPWayBackFTPTimeOut OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "WayBack FTP Timeout: a request must be finished within this periode of time." ::= { wtWebioEA12x6RelERPWayBack 5 } -- wtWebioEA12x6RelERPOutputMode Group -------------------------------- -- OutputMode Table wtWebioEA12x6RelERPOutputModeTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelERPOutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of output mode configurations dependent on the output indices." ::= { wtWebioEA12x6RelERPOutputMode 1 } wtWebioEA12x6RelERPOutputModeEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelERPOutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output mode configurations of the individual outputs." INDEX { wtWebioEA12x6RelERPOutputNo } ::= { wtWebioEA12x6RelERPOutputModeTable 1 } WtWebioEA12x6RelERPOutputModeEntry ::= SEQUENCE { wtWebioEA12x6RelERPOutputModeBit OCTET STRING } wtWebioEA12x6RelERPOutputModeBit OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebioEA12x6RelERPOutputModeEntry 1 } wtWebioEA12x6RelERPSafetyTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined." ::= { wtWebioEA12x6RelERPOutputMode 2 } -- wtWebioEA12x6RelERPAlarm Group ---------------------------- wtWebioEA12x6RelERPAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebioEA12x6RelERPAlarm 1 } -- Alarm Interface Table wtWebioEA12x6RelERPAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelERPAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebioEA12x6RelERPAlarm 2 } wtWebioEA12x6RelERPAlarmIfEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelERPAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebioEA12x6RelERPAlarmNo } ::= { wtWebioEA12x6RelERPAlarmIfTable 1 } WtWebioEA12x6RelERPAlarmIfEntry ::= SEQUENCE { wtWebioEA12x6RelERPAlarmNo INTEGER } wtWebioEA12x6RelERPAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtWebioEA12x6RelERPAlarmIfEntry 1 } -- Alarm Table wtWebioEA12x6RelERPAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelERPAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebioEA12x6RelERPAlarm 3 } wtWebioEA12x6RelERPAlarmEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelERPAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebioEA12x6RelERPAlarmNo } ::= { wtWebioEA12x6RelERPAlarmTable 1 } WtWebioEA12x6RelERPAlarmEntry ::= SEQUENCE { wtWebioEA12x6RelERPAlarmInputTrigger OCTET STRING, wtWebioEA12x6RelERPAlarmOutputTrigger OCTET STRING, wtWebioEA12x6RelERPAlarmSystemTrigger OCTET STRING, wtWebioEA12x6RelERPAlarmMaxCounterValue OCTET STRING, wtWebioEA12x6RelERPAlarmInterval OCTET STRING, wtWebioEA12x6RelERPAlarmEnable OCTET STRING, wtWebioEA12x6RelERPAlarmMailAddr OCTET STRING, wtWebioEA12x6RelERPAlarmMailSubject OCTET STRING, wtWebioEA12x6RelERPAlarmMailText OCTET STRING, wtWebioEA12x6RelERPAlarmSnmpManagerIP OCTET STRING, wtWebioEA12x6RelERPAlarmSnmpTrapText OCTET STRING, wtWebioEA12x6RelERPAlarmUdpIpAddr OCTET STRING, wtWebioEA12x6RelERPAlarmUdpPort INTEGER, wtWebioEA12x6RelERPAlarmUdpText OCTET STRING, wtWebioEA12x6RelERPAlarmTcpIpAddr OCTET STRING, wtWebioEA12x6RelERPAlarmTcpPort INTEGER, wtWebioEA12x6RelERPAlarmTcpText OCTET STRING, wtWebioEA12x6RelERPAlarmSyslogIpAddr OCTET STRING, wtWebioEA12x6RelERPAlarmSyslogPort INTEGER, wtWebioEA12x6RelERPAlarmSyslogText OCTET STRING, wtWebioEA12x6RelERPAlarmFtpDataPort OCTET STRING, wtWebioEA12x6RelERPAlarmFtpFileName OCTET STRING, wtWebioEA12x6RelERPAlarmFtpText OCTET STRING, wtWebioEA12x6RelERPAlarmFtpOption OCTET STRING, wtWebioEA12x6RelERPAlarmTimerCron OCTET STRING, wtWebioEA12x6RelERPAlarmMailReleaseSubject OCTET STRING, wtWebioEA12x6RelERPAlarmMailReleaseText OCTET STRING, wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText OCTET STRING, wtWebioEA12x6RelERPAlarmUdpReleaseText OCTET STRING, wtWebioEA12x6RelERPAlarmTcpReleaseText OCTET STRING, wtWebioEA12x6RelERPAlarmSyslogReleaseText OCTET STRING, wtWebioEA12x6RelERPAlarmFtpReleaseText OCTET STRING } wtWebioEA12x6RelERPAlarmInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3, Bit 0-3: Mask for digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Mask for digital inputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7, Bit 0-3: Level of digital inputs 8-11 Bit 4-7: unused OCTET 8, Bit 0-7: Level of digital inputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11 Bit 12-15 : unused OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7" ::= { wtWebioEA12x6RelERPAlarmEntry 1 } wtWebioEA12x6RelERPAlarmOutputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-5: Mask for digital outputs 0-5 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-5: Level of digital outputs 0-5 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unused OCTET 11: unused OCTET 12: Bit 0-5: ANY bits of digital outputs 0-5" ::= { wtWebioEA12x6RelERPAlarmEntry 2 } wtWebioEA12x6RelERPAlarmSystemTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control" ::= { wtWebioEA12x6RelERPAlarmEntry 3 } wtWebioEA12x6RelERPAlarmMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA12x6RelERPAlarmInputTrigger are not considered." ::= { wtWebioEA12x6RelERPAlarmEntry 4 } wtWebioEA12x6RelERPAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebioEA12x6RelERPAlarmEntry 5 } wtWebioEA12x6RelERPAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused" ::= { wtWebioEA12x6RelERPAlarmEntry 6 } wtWebioEA12x6RelERPAlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebioEA12x6RelERPAlarmEntry 7 } wtWebioEA12x6RelERPAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA12x6RelERPAlarmEntry 8 } wtWebioEA12x6RelERPAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA12x6RelERPAlarmEntry 9 } wtWebioEA12x6RelERPAlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebioEA12x6RelERPAlarmEntry 10 } wtWebioEA12x6RelERPAlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA12x6RelERPAlarmEntry 11 } wtWebioEA12x6RelERPAlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA12x6RelERPAlarmEntry 12 } wtWebioEA12x6RelERPAlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA12x6RelERPAlarmEntry 13 } wtWebioEA12x6RelERPAlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA12x6RelERPAlarmEntry 14 } wtWebioEA12x6RelERPAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA12x6RelERPAlarmEntry 15 } wtWebioEA12x6RelERPAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA12x6RelERPAlarmEntry 16 } wtWebioEA12x6RelERPAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA12x6RelERPAlarmEntry 17 } wtWebioEA12x6RelERPAlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA12x6RelERPAlarmEntry 18 } wtWebioEA12x6RelERPAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA12x6RelERPAlarmEntry 19 } wtWebioEA12x6RelERPAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA12x6RelERPAlarmEntry 20 } wtWebioEA12x6RelERPAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebioEA12x6RelERPAlarmEntry 21 } wtWebioEA12x6RelERPAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebioEA12x6RelERPAlarmEntry 22 } wtWebioEA12x6RelERPAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA12x6RelERPAlarmEntry 23 } wtWebioEA12x6RelERPAlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebioEA12x6RelERPAlarmEntry 24 } wtWebioEA12x6RelERPAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebioEA12x6RelERPAlarmEntry 25 } wtWebioEA12x6RelERPAlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA12x6RelERPAlarmEntry 26 } wtWebioEA12x6RelERPAlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA12x6RelERPAlarmEntry 27 } wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA12x6RelERPAlarmEntry 28 } wtWebioEA12x6RelERPAlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA12x6RelERPAlarmEntry 29 } wtWebioEA12x6RelERPAlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA12x6RelERPAlarmEntry 30 } wtWebioEA12x6RelERPAlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA12x6RelERPAlarmEntry 31 } wtWebioEA12x6RelERPAlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA12x6RelERPAlarmEntry 32 } -- wtWebioEA12x6RelERPPorts Group ---------------------------- -- Input Port Table wtWebioEA12x6RelERPInputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelERPInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebioEA12x6RelERPPorts 1 } wtWebioEA12x6RelERPInputPortEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelERPInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebioEA12x6RelERPInputNo } ::= { wtWebioEA12x6RelERPInputPortTable 1 } WtWebioEA12x6RelERPInputPortEntry ::= SEQUENCE { wtWebioEA12x6RelERPPortInputName OCTET STRING, wtWebioEA12x6RelERPPortInputText OCTET STRING, wtWebioEA12x6RelERPPortInputMode OCTET STRING, wtWebioEA12x6RelERPPortInputFilter INTEGER, wtWebioEA12x6RelERPPortInputBicountPulsePolarity OCTET STRING, wtWebioEA12x6RelERPPortInputBicountInactivTimeout INTEGER } wtWebioEA12x6RelERPPortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebioEA12x6RelERPInputPortEntry 1 } wtWebioEA12x6RelERPPortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebioEA12x6RelERPInputPortEntry 2 } wtWebioEA12x6RelERPPortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. Selection for input 0-3: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 3-7: unused Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable Selection for inputs 4-11: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on read Bit 0 : Change detection enable (default)" ::= { wtWebioEA12x6RelERPInputPortEntry 3 } wtWebioEA12x6RelERPPortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebioEA12x6RelERPInputPortEntry 4 } wtWebioEA12x6RelERPPortInputBicountPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA12x6RelERPInputPortEntry 5 } wtWebioEA12x6RelERPPortInputBicountInactivTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored." ::= { wtWebioEA12x6RelERPInputPortEntry 6 } -- Output Port Table wtWebioEA12x6RelERPOutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA12x6RelERPOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtWebioEA12x6RelERPPorts 2 } wtWebioEA12x6RelERPOutputPortEntry OBJECT-TYPE SYNTAX WtWebioEA12x6RelERPOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtWebioEA12x6RelERPOutputNo } ::= { wtWebioEA12x6RelERPOutputPortTable 1 } WtWebioEA12x6RelERPOutputPortEntry ::= SEQUENCE { wtWebioEA12x6RelERPPortOutputName OCTET STRING, wtWebioEA12x6RelERPPortOutputText OCTET STRING, wtWebioEA12x6RelERPPortOutputGroupMode OCTET STRING, wtWebioEA12x6RelERPPortOutputSafetyState OCTET STRING, wtWebioEA12x6RelERPPortLogicInputMask OCTET STRING, wtWebioEA12x6RelERPPortLogicInputInverter OCTET STRING, wtWebioEA12x6RelERPPortLogicFunction OCTET STRING, wtWebioEA12x6RelERPPortLogicOutputInverter OCTET STRING, wtWebioEA12x6RelERPPortPulseDuration INTEGER, wtWebioEA12x6RelERPPortPulsePolarity OCTET STRING } wtWebioEA12x6RelERPPortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtWebioEA12x6RelERPOutputPortEntry 1 } wtWebioEA12x6RelERPPortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtWebioEA12x6RelERPOutputPortEntry 2 } wtWebioEA12x6RelERPPortOutputGroupMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Unused in this device 57634" ::= { wtWebioEA12x6RelERPOutputPortEntry 3 } wtWebioEA12x6RelERPPortOutputSafetyState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH=Relais closed, 0=LOW Relais open) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output" ::= { wtWebioEA12x6RelERPOutputPortEntry 4 } wtWebioEA12x6RelERPPortLogicInputMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA12x6RelERPPortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA12x6RelERPPortLogicInputInverter) 3. Logical combination (wtWebioEA12x6RelERPPortLogicFunction) 4. Inverting the result if necessary (wtWebioEA12x6RelERPPortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : inputs 8-11 Bit 4-7 : unused OCTET 4: Bit 0-7 : inputs 0-7" ::= { wtWebioEA12x6RelERPOutputPortEntry 5 } wtWebioEA12x6RelERPPortLogicInputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : inputs 8-11 Bit 4-7 : unused OCTET 4: Bit 0-7 : inputs 0-7" ::= { wtWebioEA12x6RelERPOutputPortEntry 6 } wtWebioEA12x6RelERPPortLogicFunction OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused" ::= { wtWebioEA12x6RelERPOutputPortEntry 7 } wtWebioEA12x6RelERPPortLogicOutputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused" ::= { wtWebioEA12x6RelERPOutputPortEntry 8 } wtWebioEA12x6RelERPPortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtWebioEA12x6RelERPOutputPortEntry 9 } wtWebioEA12x6RelERPPortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtWebioEA12x6RelERPPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA12x6RelERPOutputPortEntry 10 } -- wtWebioEA12x6RelERPManufact Group ---------------------------- wtWebioEA12x6RelERPMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebioEA12x6RelERPManufact 1 } wtWebioEA12x6RelERPMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebioEA12x6RelERPManufact 2 } wtWebioEA12x6RelERPMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebioEA12x6RelERPManufact 3 } wtWebioEA12x6RelERPMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebioEA12x6RelERPManufact 4 } wtWebioEA12x6RelERPMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebioEA12x6RelERPManufact 5 } wtWebioEA12x6RelERPMfOrderNo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer part number." ::= { wtWebioEA12x6RelERPManufact 6 } -- wtWebioEA12x6RelERPDiag Group ---------------------------- wtWebioEA12x6RelERPDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebioEA12x6RelERPDiag 1 } wtWebioEA12x6RelERPDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebioEA12x6RelERPDiag 2 } wtWebioEA12x6RelERPDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebioEA12x6RelERPDiagErrorMessage. Errors are numbered from 1 to wtWebioEA12x6RelERPDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA12x6RelERPDiagErrorMessage." ::= { wtWebioEA12x6RelERPDiag 3 } wtWebioEA12x6RelERPDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebioEA12x6RelERPDiagErrorIndex as an index, the appropriate message is available." ::= { wtWebioEA12x6RelERPDiag 4 } wtWebioEA12x6RelERPDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebioEA12x6RelERPDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebioEA12x6RelERPAlert1 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtWebioEA12x6RelERPAlert2 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtWebioEA12x6RelERPAlert3 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtWebioEA12x6RelERPAlert4 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtWebioEA12x6RelERPAlert5 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtWebioEA12x6RelERPAlert6 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtWebioEA12x6RelERPAlert7 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtWebioEA12x6RelERPAlert8 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtWebioEA12x6RelERPAlert9 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtWebioEA12x6RelERPAlert10 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtWebioEA12x6RelERPAlert11 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtWebioEA12x6RelERPAlert12 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtWebioEA12x6RelERPAlert13 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebioEA12x6RelERPAlert14 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebioEA12x6RelERPAlert15 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebioEA12x6RelERPAlert16 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebioEA12x6RelERPAlert17 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebioEA12x6RelERPAlert18 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebioEA12x6RelERPAlert19 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebioEA12x6RelERPAlert20 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebioEA12x6RelERPAlert21 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtWebioEA12x6RelERPAlert22 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtWebioEA12x6RelERPAlert23 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebioEA12x6RelERPAlert24 TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebioEA12x6RelERPAlertDiag TRAP-TYPE ENTERPRISE wtWebioEA12x6RelERP VARIABLES { wtWebioEA12x6RelERPDiagErrorIndex, wtWebioEA12x6RelERPDiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtIpWatcherInOut Group ------------------------ wtIpWatcherInputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtIpWatcherInOut 1 } wtIpWatcherOutputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent outputs." ::= { wtIpWatcherInOut 2 } -- Input Interface Table wtIpWatcherInputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcherInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtIpWatcherInOut 3 } wtIpWatcherInputEntry OBJECT-TYPE SYNTAX WtIpWatcherInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtIpWatcherInputNo } ::= { wtIpWatcherInputTable 1 } WtIpWatcherInputEntry ::= SEQUENCE { wtIpWatcherInputNo INTEGER, wtIpWatcherInputCounter INTEGER, wtIpWatcherInputCounterClear INTEGER, wtIpWatcherInputState INTEGER } wtIpWatcherInputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtIpWatcherInputEntry 1 } wtIpWatcherInputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtIpWatcherInputEntry 2 } wtIpWatcherInputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtIpWatcherInputEntry 3 } wtIpWatcherInputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of a single input bit, 0-OFF, 1-ON." ::= { wtIpWatcherInputEntry 4 } wtIpWatcherInputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1" ::= { wtIpWatcherInOut 4 } -- Output Interface Table wtIpWatcherOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcherOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtIpWatcherInOut 5 } wtIpWatcherOutputEntry OBJECT-TYPE SYNTAX WtIpWatcherOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtIpWatcherOutputNo } ::= { wtIpWatcherOutputTable 1 } WtIpWatcherOutputEntry ::= SEQUENCE { wtIpWatcherOutputNo INTEGER, wtIpWatcherOutputState INTEGER } wtIpWatcherOutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtIpWatcherOutputEntry 1 } wtIpWatcherOutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of a single output bit, 0-OFF, 1-ON." ::= { wtIpWatcherOutputEntry 2 } wtIpWatcherOutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt" ::= { wtIpWatcherInOut 6 } wtIpWatcherSetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1" ::= { wtIpWatcherInOut 7 } -- Alarm Output Interface Table wtIpWatcherAlarmOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcherAlarmOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices.." ::= { wtIpWatcherInOut 8 } wtIpWatcherAlarmOutputEntry OBJECT-TYPE SYNTAX WtIpWatcherAlarmOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Index reference." INDEX { wtIpWatcherAlarmNo } ::= { wtIpWatcherAlarmOutputTable 1 } WtIpWatcherAlarmOutputEntry ::= SEQUENCE { wtIpWatcherAlarmOutputState INTEGER, wtIpWatcherAlarmTriggerState INTEGER } wtIpWatcherAlarmOutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "State of the alarm, 0-OFF, 1-ON." ::= { wtIpWatcherAlarmOutputEntry 1 } wtIpWatcherAlarmTriggerState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "State of the trigger condition, 0-OFF, 1-ON." ::= { wtIpWatcherAlarmOutputEntry 2 } -- wtIpWatcherSessCntrl Group -------------------------------- wtIpWatcherSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtIpWatcherSessCntrlLogout. When read this variable provides a string of length zero." ::= { wtIpWatcherSessCntrl 1 } wtIpWatcherSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtIpWatcherSessCntrl 2 } wtIpWatcherSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtIpWatcherSessCntrl 3 } wtIpWatcherSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtIpWatcherSessCntrl 4 } wtIpWatcherSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtIpWatcherSessCntrl 5 } -- wtIpWatcherText Group ------------------------ wtIpWatcherDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtIpWatcherText 1 } wtIpWatcherDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtIpWatcherText 2 } wtIpWatcherDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtIpWatcherText 3 } wtIpWatcherDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtIpWatcherText 4 } -- wtIpWatcherTimeZone Group ---------------------------- wtIpWatcherTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtIpWatcherTimeZone 1 } wtIpWatcherTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtIpWatcherTimeZone 2 } wtIpWatcherTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtIpWatcherTimeZone 3 } wtIpWatcherStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtIpWatcherTimeZone 4 } wtIpWatcherStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtIpWatcherTimeZone 5 } wtIpWatcherStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtIpWatcherTimeZone 6 } wtIpWatcherStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtIpWatcherStartMonth-January(1), wtIpWatcherStartMonth-February(2), wtIpWatcherStartMonth-March(3), wtIpWatcherStartMonth-April(4), wtIpWatcherStartMonth-May(5), wtIpWatcherStartMonth-June(6), wtIpWatcherStartMonth-July(7), wtIpWatcherStartMonth-August(8), wtIpWatcherStartMonth-September(9), wtIpWatcherStartMonth-October(10), wtIpWatcherStartMonth-November(11), wtIpWatcherStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtIpWatcherTimeZone 7 } wtIpWatcherStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtIpWatcherStartMode-first(1), wtIpWatcherStartMode-second(2), wtIpWatcherStartMode-third(3), wtIpWatcherStartMode-fourth(4), wtIpWatcherStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtIpWatcherTimeZone 8 } wtIpWatcherStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtIpWatcherStartWday-Sunday(1), wtIpWatcherStartWday-Monday(2), wtIpWatcherStartWday-Tuesday(3), wtIpWatcherStartWday-Thursday(4), wtIpWatcherStartWday-Wednesday(5), wtIpWatcherStartWday-Friday(6), wtIpWatcherStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtIpWatcherTimeZone 9 } wtIpWatcherStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtIpWatcherTimeZone 10 } wtIpWatcherStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtIpWatcherTimeZone 11 } wtIpWatcherStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtIpWatcherStopMonth-January(1), wtIpWatcherStopMonth-February(2), wtIpWatcherStopMonth-March(3), wtIpWatcherStopMonth-April(4), wtIpWatcherStopMonth-May(5), wtIpWatcherStopMonth-June(6), wtIpWatcherStopMonth-July(7), wtIpWatcherStopMonth-August(8), wtIpWatcherStopMonth-September(9), wtIpWatcherStopMonth-October(10), wtIpWatcherStopMonth-November(11), wtIpWatcherStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtIpWatcherTimeZone 12 } wtIpWatcherStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtIpWatcherStopMode-first(1), wtIpWatcherStopMode-second(2), wtIpWatcherStopMode-third(3), wtIpWatcherStopMode-fourth(4), wtIpWatcherStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtIpWatcherTimeZone 13 } wtIpWatcherStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtIpWatcherStopWday-Sunday(1), wtIpWatcherStopWday-Monday(2), wtIpWatcherStopWday-Tuesday(3), wtIpWatcherStopWday-Thursday(4), wtIpWatcherStopWday-Wednesday(5), wtIpWatcherStopWday-Friday(6), wtIpWatcherStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtIpWatcherTimeZone 14 } wtIpWatcherStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtIpWatcherTimeZone 15 } wtIpWatcherStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtIpWatcherTimeZone 16 } -- wtIpWatcherTimeServer Group ---------------------------- wtIpWatcherTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtIpWatcherTimeServer 1 } wtIpWatcherTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtIpWatcherTimeServer 2 } wtIpWatcherTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtIpWatcherTimeServer 3 } wtIpWatcherTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtIpWatcherTimeServer 4 } -- wtIpWatcherDeviceClock Group ---------------------------- wtIpWatcherClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtIpWatcherDeviceClock 1 } wtIpWatcherClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtIpWatcherDeviceClock 2 } wtIpWatcherClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtIpWatcherDeviceClock 3 } wtIpWatcherClockMonth OBJECT-TYPE SYNTAX INTEGER { wtIpWatcherClockMonth-January(1), wtIpWatcherClockMonth-February(2), wtIpWatcherClockMonth-March(3), wtIpWatcherClockMonth-April(4), wtIpWatcherClockMonth-May(5), wtIpWatcherClockMonth-June(6), wtIpWatcherClockMonth-July(7), wtIpWatcherClockMonth-August(8), wtIpWatcherClockMonth-September(9), wtIpWatcherClockMonth-October(10), wtIpWatcherClockMonth-November(11), wtIpWatcherClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtIpWatcherDeviceClock 4 } wtIpWatcherClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtIpWatcherDeviceClock 5 } -- wtIpWatcherNetwork Group ------------------------ wtIpWatcherIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtIpWatcherNetwork 1 } wtIpWatcherSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtIpWatcherNetwork 2 } wtIpWatcherGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtIpWatcherNetwork 3 } wtIpWatcherDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtIpWatcherNetwork 4 } wtIpWatcherDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtIpWatcherNetwork 5 } wtIpWatcherAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtIpWatcherNetwork 6 } -- wtIpWatcherHTTP Group -------------------------------- wtIpWatcherHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtIpWatcherHTTP 4 } -- wtIpWatcherMail Group -------------------------------- wtIpWatcherMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtIpWatcherMail 1 } wtIpWatcherMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtIpWatcherMail 2 } wtIpWatcherMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtIpWatcherMail 3 } wtIpWatcherMailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtIpWatcherMail 4 } wtIpWatcherMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtIpWatcherMail 5 } wtIpWatcherMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtIpWatcherMail 6 } wtIpWatcherMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtIpWatcherMail 7 } wtIpWatcherMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtIpWatcherMail 8 } -- wtIpWatcherSnmp Group -------------------------------- wtIpWatcherSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtIpWatcherSNMP 1 } wtIpWatcherSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtIpWatcherSNMP 2 } wtIpWatcherSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtIpWatcherSNMP 3 } wtIpWatcherSnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtIpWatcherSNMP 4 } wtIpWatcherSnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtIpWatcherSNMP 5 } -- wtIpWatcherUDP Group -------------------------------- wtIpWatcherUdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtIpWatcherUDP 1 } wtIpWatcherUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtIpWatcherUDP 2 } wtIpWatcherUdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtIpWatcherUDP 3 } -- wtIpWatcherSyslog Group -------------------------------- wtIpWatcherSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtIpWatcherSyslog 1 } wtIpWatcherSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtIpWatcherSyslog 2 } wtIpWatcherSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtIpWatcherSyslog 3 } wtIpWatcherSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtIpWatcherSyslog 4 } -- wtIpWatcherFTP Group -------------------------------- wtIpWatcherFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtIpWatcherFTP 1 } wtIpWatcherFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtIpWatcherFTP 2 } wtIpWatcherFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtIpWatcherFTP 3 } wtIpWatcherFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtIpWatcherFTP 4 } wtIpWatcherFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtIpWatcherFTP 5 } wtIpWatcherFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtIpWatcherFTP 6 } wtIpWatcherFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtIpWatcherFTP 7 } -- wtIpWatcherIpList Group ---------------------------- wtIpWatcherIpListCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Ip addresses." ::= { wtIpWatcherIpList 1 } -- IpList Interface Table wtIpWatcherIpListIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcherIpListIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of inices." ::= { wtIpWatcherIpList 2 } wtIpWatcherIpListIfEntry OBJECT-TYPE SYNTAX WtIpWatcherIpListIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table entry." INDEX { wtIpWatcherIpListNo } ::= { wtIpWatcherIpListIfTable 1 } WtIpWatcherIpListIfEntry ::= SEQUENCE { wtIpWatcherIpListNo INTEGER } wtIpWatcherIpListNo OBJECT-TYPE SYNTAX INTEGER (1..999) ACCESS read-only STATUS mandatory DESCRIPTION "List number of this entry." ::= { wtIpWatcherIpListIfEntry 1 } -- IpList Table wtIpWatcherIpListTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcherIpListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of ip addresses." ::= { wtIpWatcherIpList 3 } wtIpWatcherIpListEntry OBJECT-TYPE SYNTAX WtIpWatcherIpListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List entry." INDEX { wtIpWatcherIpListNo } ::= { wtIpWatcherIpListTable 1 } WtIpWatcherIpListEntry ::= SEQUENCE { wtIpWatcherIpListName OCTET STRING, wtIpWatcherIpListPort INTEGER, wtIpWatcherIpListService OCTET STRING, wtIpWatcherIpListEnable OCTET STRING, wtIpWatcherIpListAlias OCTET STRING } wtIpWatcherIpListName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address." ::= { wtIpWatcherIpListEntry 1 } wtIpWatcherIpListPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number, zero in the case of broadcast or Ping." ::= { wtIpWatcherIpListEntry 2 } wtIpWatcherIpListService OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded scan mode, only one mode can be selected at a particular time: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Ping enable Bit 1-7: unused" ::= { wtIpWatcherIpListEntry 3 } wtIpWatcherIpListEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: enabled in Alarm 1 Bit 1: enabled in Alarm 2 Bit 2: enabled in Alarm 3 Bit 3: enabled in Alarm 4 Bit 4-7: unused" ::= { wtIpWatcherIpListEntry 4 } wtIpWatcherIpListAlias OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alias Name" ::= { wtIpWatcherIpListEntry 5 } -- wtIpWatcherAlarm Group ---------------------------- wtIpWatcherAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtIpWatcherAlarm 1 } -- Alarm Interface Table wtIpWatcherAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcherAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtIpWatcherAlarm 2 } wtIpWatcherAlarmIfEntry OBJECT-TYPE SYNTAX WtIpWatcherAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtIpWatcherAlarmNo } ::= { wtIpWatcherAlarmIfTable 1 } WtIpWatcherAlarmIfEntry ::= SEQUENCE { wtIpWatcherAlarmNo INTEGER } wtIpWatcherAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtIpWatcherAlarmIfEntry 1 } -- Alarm Table wtIpWatcherAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcherAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtIpWatcherAlarm 3 } wtIpWatcherAlarmEntry OBJECT-TYPE SYNTAX WtIpWatcherAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtIpWatcherAlarmNo } ::= { wtIpWatcherAlarmTable 1 } WtIpWatcherAlarmEntry ::= SEQUENCE { wtIpWatcherAlarmInterval OCTET STRING, wtIpWatcherAlarmEnable OCTET STRING, wtIpWatcherAlarmMailAddr OCTET STRING, wtIpWatcherAlarmMailSubject OCTET STRING, wtIpWatcherAlarmMailText OCTET STRING, wtIpWatcherAlarmSnmpManagerIP OCTET STRING, wtIpWatcherAlarmSnmpTrapText OCTET STRING, wtIpWatcherAlarmUdpIpAddr OCTET STRING, wtIpWatcherAlarmUdpPort INTEGER, wtIpWatcherAlarmUdpText OCTET STRING, wtIpWatcherAlarmTcpIpAddr OCTET STRING, wtIpWatcherAlarmTcpPort INTEGER, wtIpWatcherAlarmTcpText OCTET STRING, wtIpWatcherAlarmSyslogIpAddr OCTET STRING, wtIpWatcherAlarmSyslogPort INTEGER, wtIpWatcherAlarmSyslogText OCTET STRING, wtIpWatcherAlarmFtpDataPort OCTET STRING, wtIpWatcherAlarmFtpFileName OCTET STRING, wtIpWatcherAlarmFtpText OCTET STRING, wtIpWatcherAlarmFtpOption OCTET STRING, wtIpWatcherAlarmTimerCron OCTET STRING, wtIpWatcherAlarmMailReleaseSubject OCTET STRING, wtIpWatcherAlarmMailReleaseText OCTET STRING, wtIpWatcherAlarmSnmpTrapReleaseText OCTET STRING, wtIpWatcherAlarmUdpReleaseText OCTET STRING, wtIpWatcherAlarmTcpReleaseText OCTET STRING, wtIpWatcherAlarmSyslogReleaseText OCTET STRING, wtIpWatcherAlarmFtpReleaseText OCTET STRING, wtIpWatcherAlarmName OCTET STRING, wtIpWatcherAlarmGlobalEnable OCTET STRING, wtIpWatcherAlarmCounterClear OCTET STRING, wtIpWatcherAlarmAckEnable OCTET STRING, wtIpWatcherAlarmAckPort INTEGER, wtIpWatcherAlarmSetPort INTEGER, wtIpWatcherAlarmMailTrgClearSubject OCTET STRING, wtIpWatcherAlarmMailTrgClearText OCTET STRING, wtIpWatcherAlarmSnmpTrapTrgClearText OCTET STRING, wtIpWatcherAlarmUdpTrgClearText OCTET STRING, wtIpWatcherAlarmTcpTrgClearText OCTET STRING, wtIpWatcherAlarmSyslogTrgClearText OCTET STRING, wtIpWatcherAlarmFtpTrgClearText OCTET STRING, wtIpWatcherAlarmMailTrapTxEnable OCTET STRING, wtIpWatcherAlarmSnmpTrapTrapTxEnable OCTET STRING, wtIpWatcherAlarmUdpTrapTxEnable OCTET STRING, wtIpWatcherAlarmTcpTrapTxEnable OCTET STRING, wtIpWatcherAlarmSyslogTrapTxEnable OCTET STRING, wtIpWatcherAlarmFtpTrapTxEnable OCTET STRING, wtIpWatcherAlarmTriggerCount INTEGER, wtIpWatcherAlarmPollingRate INTEGER } wtIpWatcherAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtIpWatcherAlarmEntry 5 } wtIpWatcherAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused" ::= { wtIpWatcherAlarmEntry 6 } wtIpWatcherAlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtIpWatcherAlarmEntry 7 } wtIpWatcherAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtIpWatcherAlarmEntry 8 } wtIpWatcherAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtIpWatcherAlarmEntry 9 } wtIpWatcherAlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtIpWatcherAlarmEntry 10 } wtIpWatcherAlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtIpWatcherAlarmEntry 11 } wtIpWatcherAlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtIpWatcherAlarmEntry 12 } wtIpWatcherAlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtIpWatcherAlarmEntry 13 } wtIpWatcherAlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtIpWatcherAlarmEntry 14 } wtIpWatcherAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtIpWatcherAlarmEntry 15 } wtIpWatcherAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtIpWatcherAlarmEntry 16 } wtIpWatcherAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtIpWatcherAlarmEntry 17 } wtIpWatcherAlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtIpWatcherAlarmEntry 18 } wtIpWatcherAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtIpWatcherAlarmEntry 19 } wtIpWatcherAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtIpWatcherAlarmEntry 20 } wtIpWatcherAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtIpWatcherAlarmEntry 21 } wtIpWatcherAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtIpWatcherAlarmEntry 22 } wtIpWatcherAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtIpWatcherAlarmEntry 23 } wtIpWatcherAlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtIpWatcherAlarmEntry 24 } wtIpWatcherAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtIpWatcherAlarmEntry 25 } wtIpWatcherAlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtIpWatcherAlarmEntry 26 } wtIpWatcherAlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtIpWatcherAlarmEntry 27 } wtIpWatcherAlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtIpWatcherAlarmEntry 28 } wtIpWatcherAlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtIpWatcherAlarmEntry 29 } wtIpWatcherAlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtIpWatcherAlarmEntry 30 } wtIpWatcherAlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtIpWatcherAlarmEntry 31 } wtIpWatcherAlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtIpWatcherAlarmEntry 32 } wtIpWatcherAlarmName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the alarm." ::= { wtIpWatcherAlarmEntry 33 } wtIpWatcherAlarmGlobalEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm activation: Die OCTETS werden bitweise interpretiert. Bit 0 entspricht dem LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Alarm enable" ::= { wtIpWatcherAlarmEntry 34 } wtIpWatcherAlarmCounterClear OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on Alarm acknowledge Bit 0 : Counter clear on Alarm send" ::= { wtIpWatcherAlarmEntry 35 } wtIpWatcherAlarmAckEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Software acknowledge enable Bit 0 : Hardware acknowledge enable" ::= { wtIpWatcherAlarmEntry 36 } wtIpWatcherAlarmAckPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of the input, which clears the alarm (1-6)." ::= { wtIpWatcherAlarmEntry 37 } wtIpWatcherAlarmSetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of the output, which will be set by this alarm (1-6). The configuration of pulse mode and polarity defined in the port output section is used." ::= { wtIpWatcherAlarmEntry 38 } wtIpWatcherAlarmMailTrgClearSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtIpWatcherAlarmEntry 39 } wtIpWatcherAlarmMailTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtIpWatcherAlarmEntry 40 } wtIpWatcherAlarmSnmpTrapTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtIpWatcherAlarmEntry 41 } wtIpWatcherAlarmUdpTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtIpWatcherAlarmEntry 42 } wtIpWatcherAlarmTcpTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtIpWatcherAlarmEntry 43 } wtIpWatcherAlarmSyslogTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtIpWatcherAlarmEntry 44 } wtIpWatcherAlarmFtpTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtIpWatcherAlarmEntry 45 } wtIpWatcherAlarmMailTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtIpWatcherAlarmEntry 46 } wtIpWatcherAlarmSnmpTrapTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtIpWatcherAlarmEntry 47 } wtIpWatcherAlarmUdpTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtIpWatcherAlarmEntry 48 } wtIpWatcherAlarmTcpTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtIpWatcherAlarmEntry 49 } wtIpWatcherAlarmSyslogTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtIpWatcherAlarmEntry 50 } wtIpWatcherAlarmFtpTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtIpWatcherAlarmEntry 51 } wtIpWatcherAlarmTriggerCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Alarm will be send if the trigger condition occours TriggerCount times." ::= { wtIpWatcherAlarmEntry 52 } wtIpWatcherAlarmPollingRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds." ::= { wtIpWatcherAlarmEntry 53 } -- wtIpWatcherPorts Group ---------------------------- -- Input Port Table wtIpWatcherInputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcherInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtIpWatcherPorts 1 } wtIpWatcherInputPortEntry OBJECT-TYPE SYNTAX WtIpWatcherInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtIpWatcherInputNo } ::= { wtIpWatcherInputPortTable 1 } WtIpWatcherInputPortEntry ::= SEQUENCE { wtIpWatcherPortInputName OCTET STRING, wtIpWatcherPortInputText OCTET STRING, wtIpWatcherPortInputFilter INTEGER } wtIpWatcherPortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtIpWatcherInputPortEntry 1 } wtIpWatcherPortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtIpWatcherInputPortEntry 2 } wtIpWatcherPortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtIpWatcherInputPortEntry 4 } -- Output Port Table wtIpWatcherOutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcherOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtIpWatcherPorts 2 } wtIpWatcherOutputPortEntry OBJECT-TYPE SYNTAX WtIpWatcherOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtIpWatcherOutputNo } ::= { wtIpWatcherOutputPortTable 1 } WtIpWatcherOutputPortEntry ::= SEQUENCE { wtIpWatcherPortOutputName OCTET STRING, wtIpWatcherPortOutputText OCTET STRING, wtIpWatcherPortPulseDuration INTEGER, wtIpWatcherPortPulsePolarity OCTET STRING } wtIpWatcherPortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtIpWatcherOutputPortEntry 1 } wtIpWatcherPortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtIpWatcherOutputPortEntry 2 } wtIpWatcherPortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtIpWatcherOutputPortEntry 9 } wtIpWatcherPortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtIpWatcherPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtIpWatcherOutputPortEntry 10 } -- wtIpWatcherManufact Group ---------------------------- wtIpWatcherMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtIpWatcherManufact 1 } wtIpWatcherMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtIpWatcherManufact 2 } wtIpWatcherMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtIpWatcherManufact 3 } wtIpWatcherMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtIpWatcherManufact 4 } wtIpWatcherMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtIpWatcherManufact 5 } -- wtIpWatcherDiag Group ---------------------------- wtIpWatcherDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtIpWatcherDiag 1 } wtIpWatcherDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtIpWatcherDiag 2 } wtIpWatcherDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtIpWatcherDiagErrorMessage. Errors are numbered from 1 to wtIpWatcherDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtIpWatcherDiagErrorMessage." ::= { wtIpWatcherDiag 3 } wtIpWatcherDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtIpWatcherDiagErrorIndex as an index, the appropriate message is available." ::= { wtIpWatcherDiag 4 } wtIpWatcherDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtIpWatcherDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtIpWatcherAlert1 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtIpWatcherAlert2 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtIpWatcherAlert3 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtIpWatcherAlert4 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtIpWatcherAlert5 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtIpWatcherAlert6 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtIpWatcherAlert7 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtIpWatcherAlert8 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtIpWatcherAlert9 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtIpWatcherAlert10 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtIpWatcherAlert11 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtIpWatcherAlert12 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtIpWatcherAlert13 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtIpWatcherAlert14 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtIpWatcherAlert15 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtIpWatcherAlert16 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtIpWatcherAlert17 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtIpWatcherAlert18 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtIpWatcherAlert19 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtIpWatcherAlert20 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtIpWatcherAlert21 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtIpWatcherAlert22 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtIpWatcherAlert23 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtIpWatcherAlert24 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtIpWatcherAlert25 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 91 wtIpWatcherAlert26 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 92 wtIpWatcherAlert27 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 93 wtIpWatcherAlert28 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 94 wtIpWatcherAlert29 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 95 wtIpWatcherAlert30 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 96 wtIpWatcherAlert31 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 97 wtIpWatcherAlert32 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 98 wtIpWatcherAlert33 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 99 wtIpWatcherAlert34 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 100 wtIpWatcherAlert35 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 101 wtIpWatcherAlert36 TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 102 wtIpWatcherAlertDiag TRAP-TYPE ENTERPRISE wtIpWatcher VARIABLES { wtIpWatcherDiagErrorIndex, wtIpWatcherDiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebioEA2x2-24VInOut Group ------------------------ wtWebioEA2x2-24VInputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtWebioEA2x2-24VInOut 1 } wtWebioEA2x2-24VOutputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent outputs." ::= { wtWebioEA2x2-24VInOut 2 } -- Input Interface Table wtWebioEA2x2-24VInputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2-24VInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebioEA2x2-24VInOut 3 } wtWebioEA2x2-24VInputEntry OBJECT-TYPE SYNTAX WtWebioEA2x2-24VInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtWebioEA2x2-24VInputNo } ::= { wtWebioEA2x2-24VInputTable 1 } WtWebioEA2x2-24VInputEntry ::= SEQUENCE { wtWebioEA2x2-24VInputNo INTEGER, wtWebioEA2x2-24VInputCounter INTEGER, wtWebioEA2x2-24VInputCounterClear INTEGER, wtWebioEA2x2-24VInputState INTEGER } wtWebioEA2x2-24VInputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebioEA2x2-24VInputEntry 1 } wtWebioEA2x2-24VInputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebioEA2x2-24VInputEntry 2 } wtWebioEA2x2-24VInputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtWebioEA2x2-24VInputEntry 3 } wtWebioEA2x2-24VInputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of a single input bit, 0-OFF, 1-ON." ::= { wtWebioEA2x2-24VInputEntry 4 } wtWebioEA2x2-24VInputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1" ::= { wtWebioEA2x2-24VInOut 4 } -- Output Interface Table wtWebioEA2x2-24VOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2-24VOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtWebioEA2x2-24VInOut 5 } wtWebioEA2x2-24VOutputEntry OBJECT-TYPE SYNTAX WtWebioEA2x2-24VOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtWebioEA2x2-24VOutputNo } ::= { wtWebioEA2x2-24VOutputTable 1 } WtWebioEA2x2-24VOutputEntry ::= SEQUENCE { wtWebioEA2x2-24VOutputNo INTEGER, wtWebioEA2x2-24VOutputState INTEGER } wtWebioEA2x2-24VOutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtWebioEA2x2-24VOutputEntry 1 } wtWebioEA2x2-24VOutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of a single output bit, 0-OFF, 1-ON." ::= { wtWebioEA2x2-24VOutputEntry 2 } wtWebioEA2x2-24VOutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt" ::= { wtWebioEA2x2-24VInOut 6 } wtWebioEA2x2-24VSetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1" ::= { wtWebioEA2x2-24VInOut 7 } -- wtWebioEA2x2-24VSessCntrl Group -------------------------------- wtWebioEA2x2-24VSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebioEA2x2-24VSessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebioEA2x2-24VSessCntrl 1 } wtWebioEA2x2-24VSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebioEA2x2-24VSessCntrl 2 } wtWebioEA2x2-24VSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebioEA2x2-24VSessCntrl 3 } wtWebioEA2x2-24VSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebioEA2x2-24VSessCntrl 4 } wtWebioEA2x2-24VSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebioEA2x2-24VSessCntrl 5 } -- wtWebioEA2x2-24VText Group ------------------------ wtWebioEA2x2-24VDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebioEA2x2-24VText 1 } wtWebioEA2x2-24VDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebioEA2x2-24VText 2 } wtWebioEA2x2-24VDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebioEA2x2-24VText 3 } wtWebioEA2x2-24VDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebioEA2x2-24VText 4 } -- wtWebioEA2x2-24VTimeZone Group ---------------------------- wtWebioEA2x2-24VTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebioEA2x2-24VTimeZone 1 } wtWebioEA2x2-24VTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebioEA2x2-24VTimeZone 2 } wtWebioEA2x2-24VTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebioEA2x2-24VTimeZone 3 } wtWebioEA2x2-24VStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebioEA2x2-24VTimeZone 4 } wtWebioEA2x2-24VStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebioEA2x2-24VTimeZone 5 } wtWebioEA2x2-24VStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebioEA2x2-24VTimeZone 6 } wtWebioEA2x2-24VStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2-24VStartMonth-January(1), wtWebioEA2x2-24VStartMonth-February(2), wtWebioEA2x2-24VStartMonth-March(3), wtWebioEA2x2-24VStartMonth-April(4), wtWebioEA2x2-24VStartMonth-May(5), wtWebioEA2x2-24VStartMonth-June(6), wtWebioEA2x2-24VStartMonth-July(7), wtWebioEA2x2-24VStartMonth-August(8), wtWebioEA2x2-24VStartMonth-September(9), wtWebioEA2x2-24VStartMonth-October(10), wtWebioEA2x2-24VStartMonth-November(11), wtWebioEA2x2-24VStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebioEA2x2-24VTimeZone 7 } wtWebioEA2x2-24VStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2-24VStartMode-first(1), wtWebioEA2x2-24VStartMode-second(2), wtWebioEA2x2-24VStartMode-third(3), wtWebioEA2x2-24VStartMode-fourth(4), wtWebioEA2x2-24VStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebioEA2x2-24VTimeZone 8 } wtWebioEA2x2-24VStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2-24VStartWday-Sunday(1), wtWebioEA2x2-24VStartWday-Monday(2), wtWebioEA2x2-24VStartWday-Tuesday(3), wtWebioEA2x2-24VStartWday-Thursday(4), wtWebioEA2x2-24VStartWday-Wednesday(5), wtWebioEA2x2-24VStartWday-Friday(6), wtWebioEA2x2-24VStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebioEA2x2-24VTimeZone 9 } wtWebioEA2x2-24VStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA2x2-24VTimeZone 10 } wtWebioEA2x2-24VStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA2x2-24VTimeZone 11 } wtWebioEA2x2-24VStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2-24VStopMonth-January(1), wtWebioEA2x2-24VStopMonth-February(2), wtWebioEA2x2-24VStopMonth-March(3), wtWebioEA2x2-24VStopMonth-April(4), wtWebioEA2x2-24VStopMonth-May(5), wtWebioEA2x2-24VStopMonth-June(6), wtWebioEA2x2-24VStopMonth-July(7), wtWebioEA2x2-24VStopMonth-August(8), wtWebioEA2x2-24VStopMonth-September(9), wtWebioEA2x2-24VStopMonth-October(10), wtWebioEA2x2-24VStopMonth-November(11), wtWebioEA2x2-24VStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebioEA2x2-24VTimeZone 12 } wtWebioEA2x2-24VStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2-24VStopMode-first(1), wtWebioEA2x2-24VStopMode-second(2), wtWebioEA2x2-24VStopMode-third(3), wtWebioEA2x2-24VStopMode-fourth(4), wtWebioEA2x2-24VStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebioEA2x2-24VTimeZone 13 } wtWebioEA2x2-24VStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2-24VStopWday-Sunday(1), wtWebioEA2x2-24VStopWday-Monday(2), wtWebioEA2x2-24VStopWday-Tuesday(3), wtWebioEA2x2-24VStopWday-Thursday(4), wtWebioEA2x2-24VStopWday-Wednesday(5), wtWebioEA2x2-24VStopWday-Friday(6), wtWebioEA2x2-24VStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebioEA2x2-24VTimeZone 14 } wtWebioEA2x2-24VStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA2x2-24VTimeZone 15 } wtWebioEA2x2-24VStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA2x2-24VTimeZone 16 } -- wtWebioEA2x2-24VTimeServer Group ---------------------------- wtWebioEA2x2-24VTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebioEA2x2-24VTimeServer 1 } wtWebioEA2x2-24VTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebioEA2x2-24VTimeServer 2 } wtWebioEA2x2-24VTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebioEA2x2-24VTimeServer 3 } wtWebioEA2x2-24VTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebioEA2x2-24VTimeServer 4 } -- wtWebioEA2x2-24VDeviceClock Group ---------------------------- wtWebioEA2x2-24VClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebioEA2x2-24VDeviceClock 1 } wtWebioEA2x2-24VClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebioEA2x2-24VDeviceClock 2 } wtWebioEA2x2-24VClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebioEA2x2-24VDeviceClock 3 } wtWebioEA2x2-24VClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2-24VClockMonth-January(1), wtWebioEA2x2-24VClockMonth-February(2), wtWebioEA2x2-24VClockMonth-March(3), wtWebioEA2x2-24VClockMonth-April(4), wtWebioEA2x2-24VClockMonth-May(5), wtWebioEA2x2-24VClockMonth-June(6), wtWebioEA2x2-24VClockMonth-July(7), wtWebioEA2x2-24VClockMonth-August(8), wtWebioEA2x2-24VClockMonth-September(9), wtWebioEA2x2-24VClockMonth-October(10), wtWebioEA2x2-24VClockMonth-November(11), wtWebioEA2x2-24VClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebioEA2x2-24VDeviceClock 4 } wtWebioEA2x2-24VClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebioEA2x2-24VDeviceClock 5 } -- wtWebioEA2x2-24VNetwork Group ------------------------ wtWebioEA2x2-24VIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebioEA2x2-24VNetwork 1 } wtWebioEA2x2-24VSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebioEA2x2-24VNetwork 2 } wtWebioEA2x2-24VGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebioEA2x2-24VNetwork 3 } wtWebioEA2x2-24VDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebioEA2x2-24VNetwork 4 } wtWebioEA2x2-24VDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebioEA2x2-24VNetwork 5 } wtWebioEA2x2-24VAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebioEA2x2-24VNetwork 6 } -- wtWebioEA2x2-24VHTTP Group -------------------------------- wtWebioEA2x2-24VStartup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebioEA2x2-24VHTTP 1 } wtWebioEA2x2-24VGetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebioEA2x2-24VHTTP 2 } wtWebioEA2x2-24VHttpInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2-24VHTTP 3 } wtWebioEA2x2-24VHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebioEA2x2-24VHTTP 4 } -- wtWebioEA2x2-24VMail Group -------------------------------- wtWebioEA2x2-24VMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebioEA2x2-24VMail 1 } wtWebioEA2x2-24VMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebioEA2x2-24VMail 2 } wtWebioEA2x2-24VMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebioEA2x2-24VMail 3 } wtWebioEA2x2-24VMailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebioEA2x2-24VMail 4 } wtWebioEA2x2-24VMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebioEA2x2-24VMail 5 } wtWebioEA2x2-24VMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebioEA2x2-24VMail 6 } wtWebioEA2x2-24VMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebioEA2x2-24VMail 7 } wtWebioEA2x2-24VMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebioEA2x2-24VMail 8 } -- wtWebioEA2x2-24VSnmp Group -------------------------------- wtWebioEA2x2-24VSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebioEA2x2-24VSNMP 1 } wtWebioEA2x2-24VSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebioEA2x2-24VSNMP 2 } wtWebioEA2x2-24VSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebioEA2x2-24VSNMP 3 } wtWebioEA2x2-24VSnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebioEA2x2-24VSNMP 4 } wtWebioEA2x2-24VSnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtWebioEA2x2-24VSNMP 5 } -- wtWebioEA2x2-24VUDP Group -------------------------------- wtWebioEA2x2-24VUdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebioEA2x2-24VUDP 1 } wtWebioEA2x2-24VUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebioEA2x2-24VUDP 2 } wtWebioEA2x2-24VUdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebioEA2x2-24VUDP 3 } -- wtWebioEA2x2-24VBinary Group -------------------------------- wtWebioEA2x2-24VBinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebioEA2x2-24VBinary 1 } -- Binary Interface Table wtWebioEA2x2-24VBinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2-24VBinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebioEA2x2-24VBinary 2 } wtWebioEA2x2-24VBinaryIfEntry OBJECT-TYPE SYNTAX WtWebioEA2x2-24VBinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebioEA2x2-24VBinaryModeNo } ::= { wtWebioEA2x2-24VBinaryIfTable 1 } WtWebioEA2x2-24VBinaryIfEntry ::= SEQUENCE { wtWebioEA2x2-24VBinaryModeNo INTEGER } wtWebioEA2x2-24VBinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebioEA2x2-24VBinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebioEA2x2-24VBinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2-24VBinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebioEA2x2-24VBinary 3 } wtWebioEA2x2-24VBinaryEntry OBJECT-TYPE SYNTAX WtWebioEA2x2-24VBinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebioEA2x2-24VBinaryModeNo } ::= { wtWebioEA2x2-24VBinaryTable 1 } WtWebioEA2x2-24VBinaryEntry ::= SEQUENCE { wtWebioEA2x2-24VBinaryOperationMode OCTET STRING, wtWebioEA2x2-24VBinaryTcpServerLocalPort INTEGER, wtWebioEA2x2-24VBinaryTcpServerInputTrigger OCTET STRING, wtWebioEA2x2-24VBinaryTcpServerApplicationMode OCTET STRING, wtWebioEA2x2-24VBinaryTcpClientLocalPort INTEGER, wtWebioEA2x2-24VBinaryTcpClientServerPort INTEGER, wtWebioEA2x2-24VBinaryTcpClientServerIpAddr OCTET STRING, wtWebioEA2x2-24VBinaryTcpClientServerPassword OCTET STRING, wtWebioEA2x2-24VBinaryTcpClientInactivity INTEGER, wtWebioEA2x2-24VBinaryTcpClientInputTrigger OCTET STRING, wtWebioEA2x2-24VBinaryTcpClientInterval INTEGER, wtWebioEA2x2-24VBinaryTcpClientApplicationMode OCTET STRING, wtWebioEA2x2-24VBinaryUdpPeerLocalPort INTEGER, wtWebioEA2x2-24VBinaryUdpPeerRemotePort INTEGER, wtWebioEA2x2-24VBinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebioEA2x2-24VBinaryUdpPeerInputTrigger OCTET STRING, wtWebioEA2x2-24VBinaryUdpPeerInterval INTEGER, wtWebioEA2x2-24VBinaryUdpPeerApplicationMode OCTET STRING, wtWebioEA2x2-24VBinaryConnectedPort INTEGER, wtWebioEA2x2-24VBinaryConnectedIpAddr IpAddress, wtWebioEA2x2-24VBinaryTcpServerClientHttpPort INTEGER, wtWebioEA2x2-24VBinaryTcpClientServerHttpPort INTEGER } wtWebioEA2x2-24VBinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebioEA2x2-24VBinaryEntry 1 } wtWebioEA2x2-24VBinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA2x2-24VBinaryEntry 2 } wtWebioEA2x2-24VBinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2-24VBinaryEntry 3 } wtWebioEA2x2-24VBinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA2x2-24VBinaryEntry 4 } wtWebioEA2x2-24VBinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA2x2-24VBinaryEntry 5 } wtWebioEA2x2-24VBinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebioEA2x2-24VBinaryEntry 6 } wtWebioEA2x2-24VBinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebioEA2x2-24VBinaryEntry 7 } wtWebioEA2x2-24VBinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebioEA2x2-24VBinaryEntry 8 } wtWebioEA2x2-24VBinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebioEA2x2-24VBinaryEntry 9 } wtWebioEA2x2-24VBinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2-24VBinaryEntry 10 } wtWebioEA2x2-24VBinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebioEA2x2-24VBinaryEntry 11 } wtWebioEA2x2-24VBinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA2x2-24VBinaryEntry 12 } wtWebioEA2x2-24VBinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA2x2-24VBinaryEntry 13 } wtWebioEA2x2-24VBinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebioEA2x2-24VBinaryEntry 14 } wtWebioEA2x2-24VBinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebioEA2x2-24VBinaryEntry 15 } wtWebioEA2x2-24VBinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2-24VBinaryEntry 16 } wtWebioEA2x2-24VBinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebioEA2x2-24VBinaryEntry 17 } wtWebioEA2x2-24VBinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA2x2-24VBinaryEntry 18 } wtWebioEA2x2-24VBinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebioEA2x2-24VBinaryEntry 19 } wtWebioEA2x2-24VBinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebioEA2x2-24VBinaryEntry 20 } wtWebioEA2x2-24VBinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebioEA2x2-24VBinaryEntry 21 } wtWebioEA2x2-24VBinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebioEA2x2-24VBinaryEntry 22 } -- wtWebioEA2x2-24VSyslog Group -------------------------------- wtWebioEA2x2-24VSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebioEA2x2-24VSyslog 1 } wtWebioEA2x2-24VSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebioEA2x2-24VSyslog 2 } wtWebioEA2x2-24VSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebioEA2x2-24VSyslog 3 } wtWebioEA2x2-24VSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebioEA2x2-24VSyslog 4 } -- wtWebioEA2x2-24VFTP Group -------------------------------- wtWebioEA2x2-24VFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebioEA2x2-24VFTP 1 } wtWebioEA2x2-24VFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioEA2x2-24VFTP 2 } wtWebioEA2x2-24VFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebioEA2x2-24VFTP 3 } wtWebioEA2x2-24VFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebioEA2x2-24VFTP 4 } wtWebioEA2x2-24VFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebioEA2x2-24VFTP 5 } wtWebioEA2x2-24VFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebioEA2x2-24VFTP 6 } wtWebioEA2x2-24VFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebioEA2x2-24VFTP 7 } -- wtWebioEA2x2-24VOutputMode Group -------------------------------- -- OutputMode Table wtWebioEA2x2-24VOutputModeTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2-24VOutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of output mode configurations dependent on the output indices." ::= { wtWebioEA2x2-24VOutputMode 1 } wtWebioEA2x2-24VOutputModeEntry OBJECT-TYPE SYNTAX WtWebioEA2x2-24VOutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output mode configurations of the individual outputs." INDEX { wtWebioEA2x2-24VOutputNo } ::= { wtWebioEA2x2-24VOutputModeTable 1 } WtWebioEA2x2-24VOutputModeEntry ::= SEQUENCE { wtWebioEA2x2-24VOutputModeBit OCTET STRING } wtWebioEA2x2-24VOutputModeBit OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebioEA2x2-24VOutputModeEntry 1 } wtWebioEA2x2-24VSafetyTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined." ::= { wtWebioEA2x2-24VOutputMode 2 } wtWebioEA2x2-24VPowerSupplyEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Setting this enable bit turns on the intarnal 24V power supply of the outputs. All currents out must not exceed 150mA. At overcurrent condition the power supply will be shut down automatically. To reset the ocvercurrent protection circuit write 1 into wtWebioEA2x2-24VDiagErrorClear. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Power Supply enable" ::= { wtWebioEA2x2-24VOutputMode 4 } -- wtWebioEA2x2-24VAlarm Group ---------------------------- wtWebioEA2x2-24VAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebioEA2x2-24VAlarm 1 } -- Alarm Interface Table wtWebioEA2x2-24VAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2-24VAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebioEA2x2-24VAlarm 2 } wtWebioEA2x2-24VAlarmIfEntry OBJECT-TYPE SYNTAX WtWebioEA2x2-24VAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebioEA2x2-24VAlarmNo } ::= { wtWebioEA2x2-24VAlarmIfTable 1 } WtWebioEA2x2-24VAlarmIfEntry ::= SEQUENCE { wtWebioEA2x2-24VAlarmNo INTEGER } wtWebioEA2x2-24VAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtWebioEA2x2-24VAlarmIfEntry 1 } -- Alarm Table wtWebioEA2x2-24VAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2-24VAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebioEA2x2-24VAlarm 3 } wtWebioEA2x2-24VAlarmEntry OBJECT-TYPE SYNTAX WtWebioEA2x2-24VAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebioEA2x2-24VAlarmNo } ::= { wtWebioEA2x2-24VAlarmTable 1 } WtWebioEA2x2-24VAlarmEntry ::= SEQUENCE { wtWebioEA2x2-24VAlarmInputTrigger OCTET STRING, wtWebioEA2x2-24VAlarmOutputTrigger OCTET STRING, wtWebioEA2x2-24VAlarmSystemTrigger OCTET STRING, wtWebioEA2x2-24VAlarmMaxCounterValue OCTET STRING, wtWebioEA2x2-24VAlarmInterval OCTET STRING, wtWebioEA2x2-24VAlarmEnable OCTET STRING, wtWebioEA2x2-24VAlarmMailAddr OCTET STRING, wtWebioEA2x2-24VAlarmMailSubject OCTET STRING, wtWebioEA2x2-24VAlarmMailText OCTET STRING, wtWebioEA2x2-24VAlarmSnmpManagerIP OCTET STRING, wtWebioEA2x2-24VAlarmSnmpTrapText OCTET STRING, wtWebioEA2x2-24VAlarmUdpIpAddr OCTET STRING, wtWebioEA2x2-24VAlarmUdpPort INTEGER, wtWebioEA2x2-24VAlarmUdpText OCTET STRING, wtWebioEA2x2-24VAlarmTcpIpAddr OCTET STRING, wtWebioEA2x2-24VAlarmTcpPort INTEGER, wtWebioEA2x2-24VAlarmTcpText OCTET STRING, wtWebioEA2x2-24VAlarmSyslogIpAddr OCTET STRING, wtWebioEA2x2-24VAlarmSyslogPort INTEGER, wtWebioEA2x2-24VAlarmSyslogText OCTET STRING, wtWebioEA2x2-24VAlarmFtpDataPort OCTET STRING, wtWebioEA2x2-24VAlarmFtpFileName OCTET STRING, wtWebioEA2x2-24VAlarmFtpText OCTET STRING, wtWebioEA2x2-24VAlarmFtpOption OCTET STRING, wtWebioEA2x2-24VAlarmTimerCron OCTET STRING, wtWebioEA2x2-24VAlarmMailReleaseSubject OCTET STRING, wtWebioEA2x2-24VAlarmMailReleaseText OCTET STRING, wtWebioEA2x2-24VAlarmSnmpTrapReleaseText OCTET STRING, wtWebioEA2x2-24VAlarmUdpReleaseText OCTET STRING, wtWebioEA2x2-24VAlarmTcpReleaseText OCTET STRING, wtWebioEA2x2-24VAlarmSyslogReleaseText OCTET STRING, wtWebioEA2x2-24VAlarmFtpReleaseText OCTET STRING } wtWebioEA2x2-24VAlarmInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital inputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital inputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1" ::= { wtWebioEA2x2-24VAlarmEntry 1 } wtWebioEA2x2-24VAlarmOutputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1" ::= { wtWebioEA2x2-24VAlarmEntry 2 } wtWebioEA2x2-24VAlarmSystemTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : unused" ::= { wtWebioEA2x2-24VAlarmEntry 3 } wtWebioEA2x2-24VAlarmMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA2x2-24VAlarmInputTrigger are not considered." ::= { wtWebioEA2x2-24VAlarmEntry 4 } wtWebioEA2x2-24VAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebioEA2x2-24VAlarmEntry 5 } wtWebioEA2x2-24VAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused" ::= { wtWebioEA2x2-24VAlarmEntry 6 } wtWebioEA2x2-24VAlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebioEA2x2-24VAlarmEntry 7 } wtWebioEA2x2-24VAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA2x2-24VAlarmEntry 8 } wtWebioEA2x2-24VAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA2x2-24VAlarmEntry 9 } wtWebioEA2x2-24VAlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebioEA2x2-24VAlarmEntry 10 } wtWebioEA2x2-24VAlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA2x2-24VAlarmEntry 11 } wtWebioEA2x2-24VAlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA2x2-24VAlarmEntry 12 } wtWebioEA2x2-24VAlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA2x2-24VAlarmEntry 13 } wtWebioEA2x2-24VAlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA2x2-24VAlarmEntry 14 } wtWebioEA2x2-24VAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA2x2-24VAlarmEntry 15 } wtWebioEA2x2-24VAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA2x2-24VAlarmEntry 16 } wtWebioEA2x2-24VAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA2x2-24VAlarmEntry 17 } wtWebioEA2x2-24VAlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA2x2-24VAlarmEntry 18 } wtWebioEA2x2-24VAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA2x2-24VAlarmEntry 19 } wtWebioEA2x2-24VAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA2x2-24VAlarmEntry 20 } wtWebioEA2x2-24VAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebioEA2x2-24VAlarmEntry 21 } wtWebioEA2x2-24VAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebioEA2x2-24VAlarmEntry 22 } wtWebioEA2x2-24VAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA2x2-24VAlarmEntry 23 } wtWebioEA2x2-24VAlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebioEA2x2-24VAlarmEntry 24 } wtWebioEA2x2-24VAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebioEA2x2-24VAlarmEntry 25 } wtWebioEA2x2-24VAlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA2x2-24VAlarmEntry 26 } wtWebioEA2x2-24VAlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA2x2-24VAlarmEntry 27 } wtWebioEA2x2-24VAlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA2x2-24VAlarmEntry 28 } wtWebioEA2x2-24VAlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA2x2-24VAlarmEntry 29 } wtWebioEA2x2-24VAlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA2x2-24VAlarmEntry 30 } wtWebioEA2x2-24VAlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA2x2-24VAlarmEntry 31 } wtWebioEA2x2-24VAlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA2x2-24VAlarmEntry 32 } -- wtWebioEA2x2-24VPorts Group ---------------------------- -- Input Port Table wtWebioEA2x2-24VInputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2-24VInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebioEA2x2-24VPorts 1 } wtWebioEA2x2-24VInputPortEntry OBJECT-TYPE SYNTAX WtWebioEA2x2-24VInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebioEA2x2-24VInputNo } ::= { wtWebioEA2x2-24VInputPortTable 1 } WtWebioEA2x2-24VInputPortEntry ::= SEQUENCE { wtWebioEA2x2-24VPortInputName OCTET STRING, wtWebioEA2x2-24VPortInputText OCTET STRING, wtWebioEA2x2-24VPortInputMode OCTET STRING, wtWebioEA2x2-24VPortInputFilter INTEGER, wtWebioEA2x2-24VPortInputBicountPulsePolarity OCTET STRING, wtWebioEA2x2-24VPortInputBicountInactivTimeout INTEGER } wtWebioEA2x2-24VPortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebioEA2x2-24VInputPortEntry 1 } wtWebioEA2x2-24VPortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebioEA2x2-24VInputPortEntry 2 } wtWebioEA2x2-24VPortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. Selection for input 0-1: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Bidirectional counter enable Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable" ::= { wtWebioEA2x2-24VInputPortEntry 3 } wtWebioEA2x2-24VPortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebioEA2x2-24VInputPortEntry 4 } wtWebioEA2x2-24VPortInputBicountPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA2x2-24VInputPortEntry 5 } wtWebioEA2x2-24VPortInputBicountInactivTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored." ::= { wtWebioEA2x2-24VInputPortEntry 6 } -- Output Port Table wtWebioEA2x2-24VOutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2-24VOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtWebioEA2x2-24VPorts 2 } wtWebioEA2x2-24VOutputPortEntry OBJECT-TYPE SYNTAX WtWebioEA2x2-24VOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtWebioEA2x2-24VOutputNo } ::= { wtWebioEA2x2-24VOutputPortTable 1 } WtWebioEA2x2-24VOutputPortEntry ::= SEQUENCE { wtWebioEA2x2-24VPortOutputName OCTET STRING, wtWebioEA2x2-24VPortOutputText OCTET STRING, wtWebioEA2x2-24VPortOutputGroupMode OCTET STRING, wtWebioEA2x2-24VPortOutputSafetyState OCTET STRING, wtWebioEA2x2-24VPortLogicInputMask OCTET STRING, wtWebioEA2x2-24VPortLogicInputInverter OCTET STRING, wtWebioEA2x2-24VPortLogicFunction OCTET STRING, wtWebioEA2x2-24VPortLogicOutputInverter OCTET STRING, wtWebioEA2x2-24VPortPulseDuration INTEGER, wtWebioEA2x2-24VPortPulsePolarity OCTET STRING } wtWebioEA2x2-24VPortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtWebioEA2x2-24VOutputPortEntry 1 } wtWebioEA2x2-24VPortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtWebioEA2x2-24VOutputPortEntry 2 } wtWebioEA2x2-24VPortOutputGroupMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one ouput bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for ouputs 0-1: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : ouputs 0,1 disconnected (default) Bit 1 : ouputs 0+1 connected" ::= { wtWebioEA2x2-24VOutputPortEntry 3 } wtWebioEA2x2-24VPortOutputSafetyState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output" ::= { wtWebioEA2x2-24VOutputPortEntry 4 } wtWebioEA2x2-24VPortLogicInputMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA2x2-24VPortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA2x2-24VPortLogicInputInverter) 3. Logical combination (wtWebioEA2x2-24VPortLogicFunction) 4. Inverting the result if necessary (wtWebioEA2x2-24VPortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1" ::= { wtWebioEA2x2-24VOutputPortEntry 5 } wtWebioEA2x2-24VPortLogicInputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1" ::= { wtWebioEA2x2-24VOutputPortEntry 6 } wtWebioEA2x2-24VPortLogicFunction OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused" ::= { wtWebioEA2x2-24VOutputPortEntry 7 } wtWebioEA2x2-24VPortLogicOutputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused" ::= { wtWebioEA2x2-24VOutputPortEntry 8 } wtWebioEA2x2-24VPortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtWebioEA2x2-24VOutputPortEntry 9 } wtWebioEA2x2-24VPortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtWebioEA2x2-24VPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA2x2-24VOutputPortEntry 10 } -- wtWebioEA2x2-24VManufact Group ---------------------------- wtWebioEA2x2-24VMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebioEA2x2-24VManufact 1 } wtWebioEA2x2-24VMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebioEA2x2-24VManufact 2 } wtWebioEA2x2-24VMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebioEA2x2-24VManufact 3 } wtWebioEA2x2-24VMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebioEA2x2-24VManufact 4 } wtWebioEA2x2-24VMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebioEA2x2-24VManufact 5 } -- wtWebioEA2x2-24VDiag Group ---------------------------- wtWebioEA2x2-24VDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebioEA2x2-24VDiag 1 } wtWebioEA2x2-24VDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebioEA2x2-24VDiag 2 } wtWebioEA2x2-24VDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebioEA2x2-24VDiagErrorMessage. Errors are numbered from 1 to wtWebioEA2x2-24VDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA2x2-24VDiagErrorMessage." ::= { wtWebioEA2x2-24VDiag 3 } wtWebioEA2x2-24VDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebioEA2x2-24VDiagErrorIndex as an index, the appropriate message is available." ::= { wtWebioEA2x2-24VDiag 4 } wtWebioEA2x2-24VDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebioEA2x2-24VDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebioEA2x2-24VAlert1 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtWebioEA2x2-24VAlert2 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtWebioEA2x2-24VAlert3 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtWebioEA2x2-24VAlert4 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtWebioEA2x2-24VAlert5 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtWebioEA2x2-24VAlert6 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtWebioEA2x2-24VAlert7 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtWebioEA2x2-24VAlert8 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtWebioEA2x2-24VAlert9 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtWebioEA2x2-24VAlert10 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtWebioEA2x2-24VAlert11 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtWebioEA2x2-24VAlert12 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtWebioEA2x2-24VAlert13 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebioEA2x2-24VAlert14 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebioEA2x2-24VAlert15 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebioEA2x2-24VAlert16 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebioEA2x2-24VAlert17 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebioEA2x2-24VAlert18 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebioEA2x2-24VAlert19 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebioEA2x2-24VAlert20 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebioEA2x2-24VAlert21 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtWebioEA2x2-24VAlert22 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtWebioEA2x2-24VAlert23 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebioEA2x2-24VAlert24 TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebioEA2x2-24VAlertDiag TRAP-TYPE ENTERPRISE wtWebioEA2x2-24V VARIABLES { wtWebioEA2x2-24VDiagErrorIndex, wtWebioEA2x2-24VDiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtWebioEA2x2ERP-24VInOut Group ------------------------ wtWebioEA2x2ERP-24VInputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtWebioEA2x2ERP-24VInOut 1 } wtWebioEA2x2ERP-24VOutputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent outputs." ::= { wtWebioEA2x2ERP-24VInOut 2 } -- Input Interface Table wtWebioEA2x2ERP-24VInputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtWebioEA2x2ERP-24VInOut 3 } wtWebioEA2x2ERP-24VInputEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERP-24VInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtWebioEA2x2ERP-24VInputNo } ::= { wtWebioEA2x2ERP-24VInputTable 1 } WtWebioEA2x2ERP-24VInputEntry ::= SEQUENCE { wtWebioEA2x2ERP-24VInputNo INTEGER, wtWebioEA2x2ERP-24VInputCounter INTEGER, wtWebioEA2x2ERP-24VInputCounterClear INTEGER, wtWebioEA2x2ERP-24VInputState INTEGER } wtWebioEA2x2ERP-24VInputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtWebioEA2x2ERP-24VInputEntry 1 } wtWebioEA2x2ERP-24VInputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtWebioEA2x2ERP-24VInputEntry 2 } wtWebioEA2x2ERP-24VInputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtWebioEA2x2ERP-24VInputEntry 3 } wtWebioEA2x2ERP-24VInputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of a single input bit, 0-OFF, 1-ON." ::= { wtWebioEA2x2ERP-24VInputEntry 4 } wtWebioEA2x2ERP-24VInputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1" ::= { wtWebioEA2x2ERP-24VInOut 4 } -- Output Interface Table wtWebioEA2x2ERP-24VOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtWebioEA2x2ERP-24VInOut 5 } wtWebioEA2x2ERP-24VOutputEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERP-24VOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtWebioEA2x2ERP-24VOutputNo } ::= { wtWebioEA2x2ERP-24VOutputTable 1 } WtWebioEA2x2ERP-24VOutputEntry ::= SEQUENCE { wtWebioEA2x2ERP-24VOutputNo INTEGER, wtWebioEA2x2ERP-24VOutputState INTEGER } wtWebioEA2x2ERP-24VOutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtWebioEA2x2ERP-24VOutputEntry 1 } wtWebioEA2x2ERP-24VOutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of a single output bit, 0-OFF, 1-ON." ::= { wtWebioEA2x2ERP-24VOutputEntry 2 } wtWebioEA2x2ERP-24VOutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt" ::= { wtWebioEA2x2ERP-24VInOut 6 } wtWebioEA2x2ERP-24VSetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1" ::= { wtWebioEA2x2ERP-24VInOut 7 } -- wtWebioEA2x2ERP-24VSessCntrl Group -------------------------------- wtWebioEA2x2ERP-24VSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebioEA2x2ERP-24VSessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebioEA2x2ERP-24VSessCntrl 1 } wtWebioEA2x2ERP-24VSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebioEA2x2ERP-24VSessCntrl 2 } wtWebioEA2x2ERP-24VSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebioEA2x2ERP-24VSessCntrl 3 } wtWebioEA2x2ERP-24VSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebioEA2x2ERP-24VSessCntrl 4 } wtWebioEA2x2ERP-24VSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebioEA2x2ERP-24VSessCntrl 5 } -- wtWebioEA2x2ERP-24VText Group ------------------------ wtWebioEA2x2ERP-24VDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebioEA2x2ERP-24VText 1 } wtWebioEA2x2ERP-24VDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebioEA2x2ERP-24VText 2 } wtWebioEA2x2ERP-24VDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebioEA2x2ERP-24VText 3 } wtWebioEA2x2ERP-24VDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebioEA2x2ERP-24VText 4 } -- wtWebioEA2x2ERP-24VTimeZone Group ---------------------------- wtWebioEA2x2ERP-24VTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebioEA2x2ERP-24VTimeZone 1 } wtWebioEA2x2ERP-24VTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebioEA2x2ERP-24VTimeZone 2 } wtWebioEA2x2ERP-24VTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebioEA2x2ERP-24VTimeZone 3 } wtWebioEA2x2ERP-24VStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebioEA2x2ERP-24VTimeZone 4 } wtWebioEA2x2ERP-24VStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebioEA2x2ERP-24VTimeZone 5 } wtWebioEA2x2ERP-24VStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebioEA2x2ERP-24VTimeZone 6 } wtWebioEA2x2ERP-24VStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ERP-24VStartMonth-January(1), wtWebioEA2x2ERP-24VStartMonth-February(2), wtWebioEA2x2ERP-24VStartMonth-March(3), wtWebioEA2x2ERP-24VStartMonth-April(4), wtWebioEA2x2ERP-24VStartMonth-May(5), wtWebioEA2x2ERP-24VStartMonth-June(6), wtWebioEA2x2ERP-24VStartMonth-July(7), wtWebioEA2x2ERP-24VStartMonth-August(8), wtWebioEA2x2ERP-24VStartMonth-September(9), wtWebioEA2x2ERP-24VStartMonth-October(10), wtWebioEA2x2ERP-24VStartMonth-November(11), wtWebioEA2x2ERP-24VStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebioEA2x2ERP-24VTimeZone 7 } wtWebioEA2x2ERP-24VStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ERP-24VStartMode-first(1), wtWebioEA2x2ERP-24VStartMode-second(2), wtWebioEA2x2ERP-24VStartMode-third(3), wtWebioEA2x2ERP-24VStartMode-fourth(4), wtWebioEA2x2ERP-24VStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebioEA2x2ERP-24VTimeZone 8 } wtWebioEA2x2ERP-24VStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ERP-24VStartWday-Sunday(1), wtWebioEA2x2ERP-24VStartWday-Monday(2), wtWebioEA2x2ERP-24VStartWday-Tuesday(3), wtWebioEA2x2ERP-24VStartWday-Thursday(4), wtWebioEA2x2ERP-24VStartWday-Wednesday(5), wtWebioEA2x2ERP-24VStartWday-Friday(6), wtWebioEA2x2ERP-24VStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebioEA2x2ERP-24VTimeZone 9 } wtWebioEA2x2ERP-24VStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA2x2ERP-24VTimeZone 10 } wtWebioEA2x2ERP-24VStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioEA2x2ERP-24VTimeZone 11 } wtWebioEA2x2ERP-24VStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ERP-24VStopMonth-January(1), wtWebioEA2x2ERP-24VStopMonth-February(2), wtWebioEA2x2ERP-24VStopMonth-March(3), wtWebioEA2x2ERP-24VStopMonth-April(4), wtWebioEA2x2ERP-24VStopMonth-May(5), wtWebioEA2x2ERP-24VStopMonth-June(6), wtWebioEA2x2ERP-24VStopMonth-July(7), wtWebioEA2x2ERP-24VStopMonth-August(8), wtWebioEA2x2ERP-24VStopMonth-September(9), wtWebioEA2x2ERP-24VStopMonth-October(10), wtWebioEA2x2ERP-24VStopMonth-November(11), wtWebioEA2x2ERP-24VStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebioEA2x2ERP-24VTimeZone 12 } wtWebioEA2x2ERP-24VStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ERP-24VStopMode-first(1), wtWebioEA2x2ERP-24VStopMode-second(2), wtWebioEA2x2ERP-24VStopMode-third(3), wtWebioEA2x2ERP-24VStopMode-fourth(4), wtWebioEA2x2ERP-24VStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebioEA2x2ERP-24VTimeZone 13 } wtWebioEA2x2ERP-24VStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ERP-24VStopWday-Sunday(1), wtWebioEA2x2ERP-24VStopWday-Monday(2), wtWebioEA2x2ERP-24VStopWday-Tuesday(3), wtWebioEA2x2ERP-24VStopWday-Thursday(4), wtWebioEA2x2ERP-24VStopWday-Wednesday(5), wtWebioEA2x2ERP-24VStopWday-Friday(6), wtWebioEA2x2ERP-24VStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebioEA2x2ERP-24VTimeZone 14 } wtWebioEA2x2ERP-24VStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA2x2ERP-24VTimeZone 15 } wtWebioEA2x2ERP-24VStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioEA2x2ERP-24VTimeZone 16 } -- wtWebioEA2x2ERP-24VTimeServer Group ---------------------------- wtWebioEA2x2ERP-24VTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebioEA2x2ERP-24VTimeServer 1 } wtWebioEA2x2ERP-24VTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebioEA2x2ERP-24VTimeServer 2 } wtWebioEA2x2ERP-24VTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebioEA2x2ERP-24VTimeServer 3 } wtWebioEA2x2ERP-24VTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebioEA2x2ERP-24VTimeServer 4 } -- wtWebioEA2x2ERP-24VDeviceClock Group ---------------------------- wtWebioEA2x2ERP-24VClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebioEA2x2ERP-24VDeviceClock 1 } wtWebioEA2x2ERP-24VClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebioEA2x2ERP-24VDeviceClock 2 } wtWebioEA2x2ERP-24VClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebioEA2x2ERP-24VDeviceClock 3 } wtWebioEA2x2ERP-24VClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioEA2x2ERP-24VClockMonth-January(1), wtWebioEA2x2ERP-24VClockMonth-February(2), wtWebioEA2x2ERP-24VClockMonth-March(3), wtWebioEA2x2ERP-24VClockMonth-April(4), wtWebioEA2x2ERP-24VClockMonth-May(5), wtWebioEA2x2ERP-24VClockMonth-June(6), wtWebioEA2x2ERP-24VClockMonth-July(7), wtWebioEA2x2ERP-24VClockMonth-August(8), wtWebioEA2x2ERP-24VClockMonth-September(9), wtWebioEA2x2ERP-24VClockMonth-October(10), wtWebioEA2x2ERP-24VClockMonth-November(11), wtWebioEA2x2ERP-24VClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebioEA2x2ERP-24VDeviceClock 4 } wtWebioEA2x2ERP-24VClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebioEA2x2ERP-24VDeviceClock 5 } -- wtWebioEA2x2ERP-24VNetwork Group ------------------------ wtWebioEA2x2ERP-24VIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebioEA2x2ERP-24VNetwork 1 } wtWebioEA2x2ERP-24VSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebioEA2x2ERP-24VNetwork 2 } wtWebioEA2x2ERP-24VGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebioEA2x2ERP-24VNetwork 3 } wtWebioEA2x2ERP-24VDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebioEA2x2ERP-24VNetwork 4 } wtWebioEA2x2ERP-24VDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebioEA2x2ERP-24VNetwork 5 } wtWebioEA2x2ERP-24VAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtWebioEA2x2ERP-24VNetwork 6 } -- wtWebioEA2x2ERP-24VHTTP Group -------------------------------- wtWebioEA2x2ERP-24VStartup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebioEA2x2ERP-24VHTTP 1 } wtWebioEA2x2ERP-24VGetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebioEA2x2ERP-24VHTTP 2 } wtWebioEA2x2ERP-24VHttpInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2ERP-24VHTTP 3 } wtWebioEA2x2ERP-24VHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebioEA2x2ERP-24VHTTP 4 } -- wtWebioEA2x2ERP-24VMail Group -------------------------------- wtWebioEA2x2ERP-24VMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebioEA2x2ERP-24VMail 1 } wtWebioEA2x2ERP-24VMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebioEA2x2ERP-24VMail 2 } wtWebioEA2x2ERP-24VMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebioEA2x2ERP-24VMail 3 } wtWebioEA2x2ERP-24VMailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebioEA2x2ERP-24VMail 4 } wtWebioEA2x2ERP-24VMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebioEA2x2ERP-24VMail 5 } wtWebioEA2x2ERP-24VMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebioEA2x2ERP-24VMail 6 } wtWebioEA2x2ERP-24VMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebioEA2x2ERP-24VMail 7 } wtWebioEA2x2ERP-24VMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebioEA2x2ERP-24VMail 8 } -- wtWebioEA2x2ERP-24VSnmp Group -------------------------------- wtWebioEA2x2ERP-24VSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebioEA2x2ERP-24VSNMP 1 } wtWebioEA2x2ERP-24VSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebioEA2x2ERP-24VSNMP 2 } wtWebioEA2x2ERP-24VSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebioEA2x2ERP-24VSNMP 3 } wtWebioEA2x2ERP-24VSnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebioEA2x2ERP-24VSNMP 4 } wtWebioEA2x2ERP-24VSnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtWebioEA2x2ERP-24VSNMP 5 } -- wtWebioEA2x2ERP-24VUDP Group -------------------------------- wtWebioEA2x2ERP-24VUdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebioEA2x2ERP-24VUDP 1 } wtWebioEA2x2ERP-24VUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebioEA2x2ERP-24VUDP 2 } wtWebioEA2x2ERP-24VUdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtWebioEA2x2ERP-24VUDP 3 } -- wtWebioEA2x2ERP-24VBinary Group -------------------------------- wtWebioEA2x2ERP-24VBinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebioEA2x2ERP-24VBinary 1 } -- Binary Interface Table wtWebioEA2x2ERP-24VBinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VBinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebioEA2x2ERP-24VBinary 2 } wtWebioEA2x2ERP-24VBinaryIfEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERP-24VBinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebioEA2x2ERP-24VBinaryModeNo } ::= { wtWebioEA2x2ERP-24VBinaryIfTable 1 } WtWebioEA2x2ERP-24VBinaryIfEntry ::= SEQUENCE { wtWebioEA2x2ERP-24VBinaryModeNo INTEGER } wtWebioEA2x2ERP-24VBinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebioEA2x2ERP-24VBinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebioEA2x2ERP-24VBinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VBinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebioEA2x2ERP-24VBinary 3 } wtWebioEA2x2ERP-24VBinaryEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERP-24VBinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebioEA2x2ERP-24VBinaryModeNo } ::= { wtWebioEA2x2ERP-24VBinaryTable 1 } WtWebioEA2x2ERP-24VBinaryEntry ::= SEQUENCE { wtWebioEA2x2ERP-24VBinaryOperationMode OCTET STRING, wtWebioEA2x2ERP-24VBinaryTcpServerLocalPort INTEGER, wtWebioEA2x2ERP-24VBinaryTcpServerInputTrigger OCTET STRING, wtWebioEA2x2ERP-24VBinaryTcpServerApplicationMode OCTET STRING, wtWebioEA2x2ERP-24VBinaryTcpClientLocalPort INTEGER, wtWebioEA2x2ERP-24VBinaryTcpClientServerPort INTEGER, wtWebioEA2x2ERP-24VBinaryTcpClientServerIpAddr OCTET STRING, wtWebioEA2x2ERP-24VBinaryTcpClientServerPassword OCTET STRING, wtWebioEA2x2ERP-24VBinaryTcpClientInactivity INTEGER, wtWebioEA2x2ERP-24VBinaryTcpClientInputTrigger OCTET STRING, wtWebioEA2x2ERP-24VBinaryTcpClientInterval INTEGER, wtWebioEA2x2ERP-24VBinaryTcpClientApplicationMode OCTET STRING, wtWebioEA2x2ERP-24VBinaryUdpPeerLocalPort INTEGER, wtWebioEA2x2ERP-24VBinaryUdpPeerRemotePort INTEGER, wtWebioEA2x2ERP-24VBinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebioEA2x2ERP-24VBinaryUdpPeerInputTrigger OCTET STRING, wtWebioEA2x2ERP-24VBinaryUdpPeerInterval INTEGER, wtWebioEA2x2ERP-24VBinaryUdpPeerApplicationMode OCTET STRING, wtWebioEA2x2ERP-24VBinaryConnectedPort INTEGER, wtWebioEA2x2ERP-24VBinaryConnectedIpAddr IpAddress, wtWebioEA2x2ERP-24VBinaryTcpServerClientHttpPort INTEGER, wtWebioEA2x2ERP-24VBinaryTcpClientServerHttpPort INTEGER } wtWebioEA2x2ERP-24VBinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebioEA2x2ERP-24VBinaryEntry 1 } wtWebioEA2x2ERP-24VBinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA2x2ERP-24VBinaryEntry 2 } wtWebioEA2x2ERP-24VBinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2ERP-24VBinaryEntry 3 } wtWebioEA2x2ERP-24VBinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA2x2ERP-24VBinaryEntry 4 } wtWebioEA2x2ERP-24VBinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA2x2ERP-24VBinaryEntry 5 } wtWebioEA2x2ERP-24VBinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebioEA2x2ERP-24VBinaryEntry 6 } wtWebioEA2x2ERP-24VBinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebioEA2x2ERP-24VBinaryEntry 7 } wtWebioEA2x2ERP-24VBinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebioEA2x2ERP-24VBinaryEntry 8 } wtWebioEA2x2ERP-24VBinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebioEA2x2ERP-24VBinaryEntry 9 } wtWebioEA2x2ERP-24VBinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2ERP-24VBinaryEntry 10 } wtWebioEA2x2ERP-24VBinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebioEA2x2ERP-24VBinaryEntry 11 } wtWebioEA2x2ERP-24VBinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA2x2ERP-24VBinaryEntry 12 } wtWebioEA2x2ERP-24VBinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebioEA2x2ERP-24VBinaryEntry 13 } wtWebioEA2x2ERP-24VBinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebioEA2x2ERP-24VBinaryEntry 14 } wtWebioEA2x2ERP-24VBinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebioEA2x2ERP-24VBinaryEntry 15 } wtWebioEA2x2ERP-24VBinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1" ::= { wtWebioEA2x2ERP-24VBinaryEntry 16 } wtWebioEA2x2ERP-24VBinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebioEA2x2ERP-24VBinaryEntry 17 } wtWebioEA2x2ERP-24VBinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebioEA2x2ERP-24VBinaryEntry 18 } wtWebioEA2x2ERP-24VBinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebioEA2x2ERP-24VBinaryEntry 19 } wtWebioEA2x2ERP-24VBinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebioEA2x2ERP-24VBinaryEntry 20 } wtWebioEA2x2ERP-24VBinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebioEA2x2ERP-24VBinaryEntry 21 } wtWebioEA2x2ERP-24VBinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebioEA2x2ERP-24VBinaryEntry 22 } -- wtWebioEA2x2ERP-24VSyslog Group -------------------------------- wtWebioEA2x2ERP-24VSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebioEA2x2ERP-24VSyslog 1 } wtWebioEA2x2ERP-24VSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebioEA2x2ERP-24VSyslog 2 } wtWebioEA2x2ERP-24VSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebioEA2x2ERP-24VSyslog 3 } wtWebioEA2x2ERP-24VSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebioEA2x2ERP-24VSyslog 4 } -- wtWebioEA2x2ERP-24VFTP Group -------------------------------- wtWebioEA2x2ERP-24VFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebioEA2x2ERP-24VFTP 1 } wtWebioEA2x2ERP-24VFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioEA2x2ERP-24VFTP 2 } wtWebioEA2x2ERP-24VFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebioEA2x2ERP-24VFTP 3 } wtWebioEA2x2ERP-24VFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebioEA2x2ERP-24VFTP 4 } wtWebioEA2x2ERP-24VFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebioEA2x2ERP-24VFTP 5 } wtWebioEA2x2ERP-24VFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebioEA2x2ERP-24VFTP 6 } wtWebioEA2x2ERP-24VFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebioEA2x2ERP-24VFTP 7 } -- wtWebioEA2x2ERP-24VWayBack Group -------------------------------- wtWebioEA2x2ERP-24VWayBackEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable WayBack: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : WayBack enable" ::= { wtWebioEA2x2ERP-24VWayBack 1 } wtWebioEA2x2ERP-24VWayBackServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioEA2x2ERP-24VWayBack 2 } wtWebioEA2x2ERP-24VWayBackFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "WayBack FTP Loggin: Password of the user." ::= { wtWebioEA2x2ERP-24VWayBack 3 } wtWebioEA2x2ERP-24VWayBackFTPResponse OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "WayBack FTP response: return message after login." ::= { wtWebioEA2x2ERP-24VWayBack 4 } wtWebioEA2x2ERP-24VWayBackFTPTimeOut OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "WayBack FTP Timeout: a request must be finished within this periode of time." ::= { wtWebioEA2x2ERP-24VWayBack 5 } -- wtWebioEA2x2ERP-24VOutputMode Group -------------------------------- -- OutputMode Table wtWebioEA2x2ERP-24VOutputModeTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VOutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of output mode configurations dependent on the output indices." ::= { wtWebioEA2x2ERP-24VOutputMode 1 } wtWebioEA2x2ERP-24VOutputModeEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERP-24VOutputModeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output mode configurations of the individual outputs." INDEX { wtWebioEA2x2ERP-24VOutputNo } ::= { wtWebioEA2x2ERP-24VOutputModeTable 1 } WtWebioEA2x2ERP-24VOutputModeEntry ::= SEQUENCE { wtWebioEA2x2ERP-24VOutputModeBit OCTET STRING } wtWebioEA2x2ERP-24VOutputModeBit OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebioEA2x2ERP-24VOutputModeEntry 1 } wtWebioEA2x2ERP-24VSafetyTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined." ::= { wtWebioEA2x2ERP-24VOutputMode 2 } wtWebioEA2x2ERP-24VLoadControlEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Here the function of automatic load control can be enabled. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Load Control enable" ::= { wtWebioEA2x2ERP-24VOutputMode 3 } wtWebioEA2x2ERP-24VPowerSupplyEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Setting this enable bit turns on the intarnal 24V power supply of the outputs. All currents out must not exceed 150mA. At overcurrent condition the power supply will be shut down automatically. To reset the ocvercurrent protection circuit write 1 into wtWebioEA2x2DiagErrorClear. Internal power supply is a feature of 57638 only. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Power Supply enable" ::= { wtWebioEA2x2ERP-24VOutputMode 4 } -- wtWebioEA2x2ERP-24VAlarm Group ---------------------------- wtWebioEA2x2ERP-24VAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebioEA2x2ERP-24VAlarm 1 } -- Alarm Interface Table wtWebioEA2x2ERP-24VAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebioEA2x2ERP-24VAlarm 2 } wtWebioEA2x2ERP-24VAlarmIfEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERP-24VAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebioEA2x2ERP-24VAlarmNo } ::= { wtWebioEA2x2ERP-24VAlarmIfTable 1 } WtWebioEA2x2ERP-24VAlarmIfEntry ::= SEQUENCE { wtWebioEA2x2ERP-24VAlarmNo INTEGER } wtWebioEA2x2ERP-24VAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtWebioEA2x2ERP-24VAlarmIfEntry 1 } -- Alarm Table wtWebioEA2x2ERP-24VAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebioEA2x2ERP-24VAlarm 3 } wtWebioEA2x2ERP-24VAlarmEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERP-24VAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebioEA2x2ERP-24VAlarmNo } ::= { wtWebioEA2x2ERP-24VAlarmTable 1 } WtWebioEA2x2ERP-24VAlarmEntry ::= SEQUENCE { wtWebioEA2x2ERP-24VAlarmInputTrigger OCTET STRING, wtWebioEA2x2ERP-24VAlarmOutputTrigger OCTET STRING, wtWebioEA2x2ERP-24VAlarmSystemTrigger OCTET STRING, wtWebioEA2x2ERP-24VAlarmMaxCounterValue OCTET STRING, wtWebioEA2x2ERP-24VAlarmInterval OCTET STRING, wtWebioEA2x2ERP-24VAlarmEnable OCTET STRING, wtWebioEA2x2ERP-24VAlarmMailAddr OCTET STRING, wtWebioEA2x2ERP-24VAlarmMailSubject OCTET STRING, wtWebioEA2x2ERP-24VAlarmMailText OCTET STRING, wtWebioEA2x2ERP-24VAlarmSnmpManagerIP OCTET STRING, wtWebioEA2x2ERP-24VAlarmSnmpTrapText OCTET STRING, wtWebioEA2x2ERP-24VAlarmUdpIpAddr OCTET STRING, wtWebioEA2x2ERP-24VAlarmUdpPort INTEGER, wtWebioEA2x2ERP-24VAlarmUdpText OCTET STRING, wtWebioEA2x2ERP-24VAlarmTcpIpAddr OCTET STRING, wtWebioEA2x2ERP-24VAlarmTcpPort INTEGER, wtWebioEA2x2ERP-24VAlarmTcpText OCTET STRING, wtWebioEA2x2ERP-24VAlarmSyslogIpAddr OCTET STRING, wtWebioEA2x2ERP-24VAlarmSyslogPort INTEGER, wtWebioEA2x2ERP-24VAlarmSyslogText OCTET STRING, wtWebioEA2x2ERP-24VAlarmFtpDataPort OCTET STRING, wtWebioEA2x2ERP-24VAlarmFtpFileName OCTET STRING, wtWebioEA2x2ERP-24VAlarmFtpText OCTET STRING, wtWebioEA2x2ERP-24VAlarmFtpOption OCTET STRING, wtWebioEA2x2ERP-24VAlarmTimerCron OCTET STRING, wtWebioEA2x2ERP-24VAlarmMailReleaseSubject OCTET STRING, wtWebioEA2x2ERP-24VAlarmMailReleaseText OCTET STRING, wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText OCTET STRING, wtWebioEA2x2ERP-24VAlarmUdpReleaseText OCTET STRING, wtWebioEA2x2ERP-24VAlarmTcpReleaseText OCTET STRING, wtWebioEA2x2ERP-24VAlarmSyslogReleaseText OCTET STRING, wtWebioEA2x2ERP-24VAlarmFtpReleaseText OCTET STRING } wtWebioEA2x2ERP-24VAlarmInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital inputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital inputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1" ::= { wtWebioEA2x2ERP-24VAlarmEntry 1 } wtWebioEA2x2ERP-24VAlarmOutputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1" ::= { wtWebioEA2x2ERP-24VAlarmEntry 2 } wtWebioEA2x2ERP-24VAlarmSystemTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control" ::= { wtWebioEA2x2ERP-24VAlarmEntry 3 } wtWebioEA2x2ERP-24VAlarmMaxCounterValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA2x2ERP-24VAlarmInputTrigger are not considered." ::= { wtWebioEA2x2ERP-24VAlarmEntry 4 } wtWebioEA2x2ERP-24VAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebioEA2x2ERP-24VAlarmEntry 5 } wtWebioEA2x2ERP-24VAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused" ::= { wtWebioEA2x2ERP-24VAlarmEntry 6 } wtWebioEA2x2ERP-24VAlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebioEA2x2ERP-24VAlarmEntry 7 } wtWebioEA2x2ERP-24VAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA2x2ERP-24VAlarmEntry 8 } wtWebioEA2x2ERP-24VAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA2x2ERP-24VAlarmEntry 9 } wtWebioEA2x2ERP-24VAlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebioEA2x2ERP-24VAlarmEntry 10 } wtWebioEA2x2ERP-24VAlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA2x2ERP-24VAlarmEntry 11 } wtWebioEA2x2ERP-24VAlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA2x2ERP-24VAlarmEntry 12 } wtWebioEA2x2ERP-24VAlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtWebioEA2x2ERP-24VAlarmEntry 13 } wtWebioEA2x2ERP-24VAlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA2x2ERP-24VAlarmEntry 14 } wtWebioEA2x2ERP-24VAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA2x2ERP-24VAlarmEntry 15 } wtWebioEA2x2ERP-24VAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtWebioEA2x2ERP-24VAlarmEntry 16 } wtWebioEA2x2ERP-24VAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA2x2ERP-24VAlarmEntry 17 } wtWebioEA2x2ERP-24VAlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA2x2ERP-24VAlarmEntry 18 } wtWebioEA2x2ERP-24VAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioEA2x2ERP-24VAlarmEntry 19 } wtWebioEA2x2ERP-24VAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA2x2ERP-24VAlarmEntry 20 } wtWebioEA2x2ERP-24VAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebioEA2x2ERP-24VAlarmEntry 21 } wtWebioEA2x2ERP-24VAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebioEA2x2ERP-24VAlarmEntry 22 } wtWebioEA2x2ERP-24VAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA2x2ERP-24VAlarmEntry 23 } wtWebioEA2x2ERP-24VAlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebioEA2x2ERP-24VAlarmEntry 24 } wtWebioEA2x2ERP-24VAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebioEA2x2ERP-24VAlarmEntry 25 } wtWebioEA2x2ERP-24VAlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioEA2x2ERP-24VAlarmEntry 26 } wtWebioEA2x2ERP-24VAlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtWebioEA2x2ERP-24VAlarmEntry 27 } wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtWebioEA2x2ERP-24VAlarmEntry 28 } wtWebioEA2x2ERP-24VAlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtWebioEA2x2ERP-24VAlarmEntry 29 } wtWebioEA2x2ERP-24VAlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtWebioEA2x2ERP-24VAlarmEntry 30 } wtWebioEA2x2ERP-24VAlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioEA2x2ERP-24VAlarmEntry 31 } wtWebioEA2x2ERP-24VAlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioEA2x2ERP-24VAlarmEntry 32 } -- wtWebioEA2x2ERP-24VLoadControl ---------------------------- wtWebioEA2x2ERP-24VLoadControlView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Here the result of automatic load control can be read. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1." ::= { wtWebioEA2x2ERP-24VAlarm 4 } wtWebioEA2x2ERP-24VLCShutDownView OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Here the result of the automatic load control shut down can be read. All outputs remain switched of, until a zero is written into this variable. But previously all loads should be inspected. High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason. If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair. All controlled output could be identified reading the variable wtWebioEA2x2ERP-24VLoadControlEnable. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1." ::= { wtWebioEA2x2ERP-24VAlarm 5 } -- wtWebioEA2x2ERP-24VPorts Group ---------------------------- -- Input Port Table wtWebioEA2x2ERP-24VInputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtWebioEA2x2ERP-24VPorts 1 } wtWebioEA2x2ERP-24VInputPortEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERP-24VInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtWebioEA2x2ERP-24VInputNo } ::= { wtWebioEA2x2ERP-24VInputPortTable 1 } WtWebioEA2x2ERP-24VInputPortEntry ::= SEQUENCE { wtWebioEA2x2ERP-24VPortInputName OCTET STRING, wtWebioEA2x2ERP-24VPortInputText OCTET STRING, wtWebioEA2x2ERP-24VPortInputMode OCTET STRING, wtWebioEA2x2ERP-24VPortInputFilter INTEGER, wtWebioEA2x2ERP-24VPortInputBicountPulsePolarity OCTET STRING, wtWebioEA2x2ERP-24VPortInputBicountInactivTimeout INTEGER } wtWebioEA2x2ERP-24VPortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtWebioEA2x2ERP-24VInputPortEntry 1 } wtWebioEA2x2ERP-24VPortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtWebioEA2x2ERP-24VInputPortEntry 2 } wtWebioEA2x2ERP-24VPortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. Selection for input 0-1: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Bidirectional counter enable Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable" ::= { wtWebioEA2x2ERP-24VInputPortEntry 3 } wtWebioEA2x2ERP-24VPortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtWebioEA2x2ERP-24VInputPortEntry 4 } wtWebioEA2x2ERP-24VPortInputBicountPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA2x2ERP-24VInputPortEntry 5 } wtWebioEA2x2ERP-24VPortInputBicountInactivTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored." ::= { wtWebioEA2x2ERP-24VInputPortEntry 6 } -- Output Port Table wtWebioEA2x2ERP-24VOutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtWebioEA2x2ERP-24VPorts 2 } wtWebioEA2x2ERP-24VOutputPortEntry OBJECT-TYPE SYNTAX WtWebioEA2x2ERP-24VOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtWebioEA2x2ERP-24VOutputNo } ::= { wtWebioEA2x2ERP-24VOutputPortTable 1 } WtWebioEA2x2ERP-24VOutputPortEntry ::= SEQUENCE { wtWebioEA2x2ERP-24VPortOutputName OCTET STRING, wtWebioEA2x2ERP-24VPortOutputText OCTET STRING, wtWebioEA2x2ERP-24VPortOutputGroupMode OCTET STRING, wtWebioEA2x2ERP-24VPortOutputSafetyState OCTET STRING, wtWebioEA2x2ERP-24VPortLogicInputMask OCTET STRING, wtWebioEA2x2ERP-24VPortLogicInputInverter OCTET STRING, wtWebioEA2x2ERP-24VPortLogicFunction OCTET STRING, wtWebioEA2x2ERP-24VPortLogicOutputInverter OCTET STRING, wtWebioEA2x2ERP-24VPortPulseDuration INTEGER, wtWebioEA2x2ERP-24VPortPulsePolarity OCTET STRING } wtWebioEA2x2ERP-24VPortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtWebioEA2x2ERP-24VOutputPortEntry 1 } wtWebioEA2x2ERP-24VPortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtWebioEA2x2ERP-24VOutputPortEntry 2 } wtWebioEA2x2ERP-24VPortOutputGroupMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one ouput bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for ouputs 0-1: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : ouputs 0,1 disconnected (default) Bit 1 : ouputs 0+1 connected" ::= { wtWebioEA2x2ERP-24VOutputPortEntry 3 } wtWebioEA2x2ERP-24VPortOutputSafetyState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output" ::= { wtWebioEA2x2ERP-24VOutputPortEntry 4 } wtWebioEA2x2ERP-24VPortLogicInputMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA2x2ERP-24VPortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA2x2ERP-24VPortLogicInputInverter) 3. Logical combination (wtWebioEA2x2ERP-24VPortLogicFunction) 4. Inverting the result if necessary (wtWebioEA2x2ERP-24VPortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1" ::= { wtWebioEA2x2ERP-24VOutputPortEntry 5 } wtWebioEA2x2ERP-24VPortLogicInputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1" ::= { wtWebioEA2x2ERP-24VOutputPortEntry 6 } wtWebioEA2x2ERP-24VPortLogicFunction OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused" ::= { wtWebioEA2x2ERP-24VOutputPortEntry 7 } wtWebioEA2x2ERP-24VPortLogicOutputInverter OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused" ::= { wtWebioEA2x2ERP-24VOutputPortEntry 8 } wtWebioEA2x2ERP-24VPortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtWebioEA2x2ERP-24VOutputPortEntry 9 } wtWebioEA2x2ERP-24VPortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtWebioEA2x2ERP-24VPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtWebioEA2x2ERP-24VOutputPortEntry 10 } -- wtWebioEA2x2ERP-24VManufact Group ---------------------------- wtWebioEA2x2ERP-24VMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebioEA2x2ERP-24VManufact 1 } wtWebioEA2x2ERP-24VMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebioEA2x2ERP-24VManufact 2 } wtWebioEA2x2ERP-24VMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebioEA2x2ERP-24VManufact 3 } wtWebioEA2x2ERP-24VMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebioEA2x2ERP-24VManufact 4 } wtWebioEA2x2ERP-24VMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebioEA2x2ERP-24VManufact 5 } -- wtWebioEA2x2ERP-24VDiag Group ---------------------------- wtWebioEA2x2ERP-24VDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebioEA2x2ERP-24VDiag 1 } wtWebioEA2x2ERP-24VDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebioEA2x2ERP-24VDiag 2 } wtWebioEA2x2ERP-24VDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebioEA2x2ERP-24VDiagErrorMessage. Errors are numbered from 1 to wtWebioEA2x2ERP-24VDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA2x2ERP-24VDiagErrorMessage." ::= { wtWebioEA2x2ERP-24VDiag 3 } wtWebioEA2x2ERP-24VDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebioEA2x2ERP-24VDiagErrorIndex as an index, the appropriate message is available." ::= { wtWebioEA2x2ERP-24VDiag 4 } wtWebioEA2x2ERP-24VDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebioEA2x2ERP-24VDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebioEA2x2ERP-24VAlert1 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtWebioEA2x2ERP-24VAlert2 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtWebioEA2x2ERP-24VAlert3 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtWebioEA2x2ERP-24VAlert4 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtWebioEA2x2ERP-24VAlert5 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtWebioEA2x2ERP-24VAlert6 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtWebioEA2x2ERP-24VAlert7 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtWebioEA2x2ERP-24VAlert8 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtWebioEA2x2ERP-24VAlert9 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtWebioEA2x2ERP-24VAlert10 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtWebioEA2x2ERP-24VAlert11 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtWebioEA2x2ERP-24VAlert12 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtWebioEA2x2ERP-24VAlert13 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebioEA2x2ERP-24VAlert14 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebioEA2x2ERP-24VAlert15 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebioEA2x2ERP-24VAlert16 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebioEA2x2ERP-24VAlert17 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebioEA2x2ERP-24VAlert18 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebioEA2x2ERP-24VAlert19 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebioEA2x2ERP-24VAlert20 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebioEA2x2ERP-24VAlert21 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtWebioEA2x2ERP-24VAlert22 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtWebioEA2x2ERP-24VAlert23 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebioEA2x2ERP-24VAlert24 TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebioEA2x2ERP-24VAlertDiag TRAP-TYPE ENTERPRISE wtWebioEA2x2ERP-24V VARIABLES { wtWebioEA2x2ERP-24VDiagErrorIndex, wtWebioEA2x2ERP-24VDiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Webio Digital Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtIpWatcher-24VInOut Group ------------------------ wtIpWatcher-24VInputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtIpWatcher-24VInOut 1 } wtIpWatcher-24VOutputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent outputs." ::= { wtIpWatcher-24VInOut 2 } -- Input Interface Table wtIpWatcher-24VInputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcher-24VInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtIpWatcher-24VInOut 3 } wtIpWatcher-24VInputEntry OBJECT-TYPE SYNTAX WtIpWatcher-24VInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtIpWatcher-24VInputNo } ::= { wtIpWatcher-24VInputTable 1 } WtIpWatcher-24VInputEntry ::= SEQUENCE { wtIpWatcher-24VInputNo INTEGER, wtIpWatcher-24VInputCounter INTEGER, wtIpWatcher-24VInputCounterClear INTEGER, wtIpWatcher-24VInputState INTEGER } wtIpWatcher-24VInputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtIpWatcher-24VInputEntry 1 } wtIpWatcher-24VInputCounter OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Value of the input counter." ::= { wtIpWatcher-24VInputEntry 2 } wtIpWatcher-24VInputCounterClear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Clears the input counter after returning its value." ::= { wtIpWatcher-24VInputEntry 3 } wtIpWatcher-24VInputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of a single input bit, 0-OFF, 1-ON." ::= { wtIpWatcher-24VInputEntry 4 } wtIpWatcher-24VInputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1" ::= { wtIpWatcher-24VInOut 4 } -- Output Interface Table wtIpWatcher-24VOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcher-24VOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtIpWatcher-24VInOut 5 } wtIpWatcher-24VOutputEntry OBJECT-TYPE SYNTAX WtIpWatcher-24VOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtIpWatcher-24VOutputNo } ::= { wtIpWatcher-24VOutputTable 1 } WtIpWatcher-24VOutputEntry ::= SEQUENCE { wtIpWatcher-24VOutputNo INTEGER, wtIpWatcher-24VOutputState INTEGER } wtIpWatcher-24VOutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtIpWatcher-24VOutputEntry 1 } wtIpWatcher-24VOutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of a single output bit, 0-OFF, 1-ON." ::= { wtIpWatcher-24VOutputEntry 2 } wtIpWatcher-24VOutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt" ::= { wtIpWatcher-24VInOut 6 } wtIpWatcher-24VSetOutput OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-write -- write-only STATUS mandatory DESCRIPTION "This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1" ::= { wtIpWatcher-24VInOut 7 } -- Alarm Output Interface Table wtIpWatcher-24VAlarmOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcher-24VAlarmOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices.." ::= { wtIpWatcher-24VInOut 8 } wtIpWatcher-24VAlarmOutputEntry OBJECT-TYPE SYNTAX WtIpWatcher-24VAlarmOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Index reference." INDEX { wtIpWatcher-24VAlarmNo } ::= { wtIpWatcher-24VAlarmOutputTable 1 } WtIpWatcher-24VAlarmOutputEntry ::= SEQUENCE { wtIpWatcher-24VAlarmOutputState INTEGER, wtIpWatcher-24VAlarmTriggerState INTEGER } wtIpWatcher-24VAlarmOutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "State of the alarm, 0-OFF, 1-ON." ::= { wtIpWatcher-24VAlarmOutputEntry 1 } wtIpWatcher-24VAlarmTriggerState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "State of the trigger condition, 0-OFF, 1-ON." ::= { wtIpWatcher-24VAlarmOutputEntry 2 } -- wtIpWatcher-24VSessCntrl Group -------------------------------- wtIpWatcher-24VSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtIpWatcher-24VSessCntrlLogout. When read this variable provides a string of length zero." ::= { wtIpWatcher-24VSessCntrl 1 } wtIpWatcher-24VSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtIpWatcher-24VSessCntrl 2 } wtIpWatcher-24VSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtIpWatcher-24VSessCntrl 3 } wtIpWatcher-24VSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtIpWatcher-24VSessCntrl 4 } wtIpWatcher-24VSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtIpWatcher-24VSessCntrl 5 } -- wtIpWatcher-24VText Group ------------------------ wtIpWatcher-24VDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtIpWatcher-24VText 1 } wtIpWatcher-24VDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtIpWatcher-24VText 2 } wtIpWatcher-24VDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtIpWatcher-24VText 3 } wtIpWatcher-24VDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtIpWatcher-24VText 4 } -- wtIpWatcher-24VTimeZone Group ---------------------------- wtIpWatcher-24VTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtIpWatcher-24VTimeZone 1 } wtIpWatcher-24VTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtIpWatcher-24VTimeZone 2 } wtIpWatcher-24VTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtIpWatcher-24VTimeZone 3 } wtIpWatcher-24VStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtIpWatcher-24VTimeZone 4 } wtIpWatcher-24VStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtIpWatcher-24VTimeZone 5 } wtIpWatcher-24VStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtIpWatcher-24VTimeZone 6 } wtIpWatcher-24VStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtIpWatcher-24VStartMonth-January(1), wtIpWatcher-24VStartMonth-February(2), wtIpWatcher-24VStartMonth-March(3), wtIpWatcher-24VStartMonth-April(4), wtIpWatcher-24VStartMonth-May(5), wtIpWatcher-24VStartMonth-June(6), wtIpWatcher-24VStartMonth-July(7), wtIpWatcher-24VStartMonth-August(8), wtIpWatcher-24VStartMonth-September(9), wtIpWatcher-24VStartMonth-October(10), wtIpWatcher-24VStartMonth-November(11), wtIpWatcher-24VStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtIpWatcher-24VTimeZone 7 } wtIpWatcher-24VStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtIpWatcher-24VStartMode-first(1), wtIpWatcher-24VStartMode-second(2), wtIpWatcher-24VStartMode-third(3), wtIpWatcher-24VStartMode-fourth(4), wtIpWatcher-24VStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtIpWatcher-24VTimeZone 8 } wtIpWatcher-24VStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtIpWatcher-24VStartWday-Sunday(1), wtIpWatcher-24VStartWday-Monday(2), wtIpWatcher-24VStartWday-Tuesday(3), wtIpWatcher-24VStartWday-Thursday(4), wtIpWatcher-24VStartWday-Wednesday(5), wtIpWatcher-24VStartWday-Friday(6), wtIpWatcher-24VStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtIpWatcher-24VTimeZone 9 } wtIpWatcher-24VStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtIpWatcher-24VTimeZone 10 } wtIpWatcher-24VStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtIpWatcher-24VTimeZone 11 } wtIpWatcher-24VStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtIpWatcher-24VStopMonth-January(1), wtIpWatcher-24VStopMonth-February(2), wtIpWatcher-24VStopMonth-March(3), wtIpWatcher-24VStopMonth-April(4), wtIpWatcher-24VStopMonth-May(5), wtIpWatcher-24VStopMonth-June(6), wtIpWatcher-24VStopMonth-July(7), wtIpWatcher-24VStopMonth-August(8), wtIpWatcher-24VStopMonth-September(9), wtIpWatcher-24VStopMonth-October(10), wtIpWatcher-24VStopMonth-November(11), wtIpWatcher-24VStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtIpWatcher-24VTimeZone 12 } wtIpWatcher-24VStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtIpWatcher-24VStopMode-first(1), wtIpWatcher-24VStopMode-second(2), wtIpWatcher-24VStopMode-third(3), wtIpWatcher-24VStopMode-fourth(4), wtIpWatcher-24VStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtIpWatcher-24VTimeZone 13 } wtIpWatcher-24VStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtIpWatcher-24VStopWday-Sunday(1), wtIpWatcher-24VStopWday-Monday(2), wtIpWatcher-24VStopWday-Tuesday(3), wtIpWatcher-24VStopWday-Thursday(4), wtIpWatcher-24VStopWday-Wednesday(5), wtIpWatcher-24VStopWday-Friday(6), wtIpWatcher-24VStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtIpWatcher-24VTimeZone 14 } wtIpWatcher-24VStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtIpWatcher-24VTimeZone 15 } wtIpWatcher-24VStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtIpWatcher-24VTimeZone 16 } -- wtIpWatcher-24VTimeServer Group ---------------------------- wtIpWatcher-24VTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtIpWatcher-24VTimeServer 1 } wtIpWatcher-24VTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtIpWatcher-24VTimeServer 2 } wtIpWatcher-24VTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtIpWatcher-24VTimeServer 3 } wtIpWatcher-24VTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtIpWatcher-24VTimeServer 4 } -- wtIpWatcher-24VDeviceClock Group ---------------------------- wtIpWatcher-24VClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtIpWatcher-24VDeviceClock 1 } wtIpWatcher-24VClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtIpWatcher-24VDeviceClock 2 } wtIpWatcher-24VClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtIpWatcher-24VDeviceClock 3 } wtIpWatcher-24VClockMonth OBJECT-TYPE SYNTAX INTEGER { wtIpWatcher-24VClockMonth-January(1), wtIpWatcher-24VClockMonth-February(2), wtIpWatcher-24VClockMonth-March(3), wtIpWatcher-24VClockMonth-April(4), wtIpWatcher-24VClockMonth-May(5), wtIpWatcher-24VClockMonth-June(6), wtIpWatcher-24VClockMonth-July(7), wtIpWatcher-24VClockMonth-August(8), wtIpWatcher-24VClockMonth-September(9), wtIpWatcher-24VClockMonth-October(10), wtIpWatcher-24VClockMonth-November(11), wtIpWatcher-24VClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtIpWatcher-24VDeviceClock 4 } wtIpWatcher-24VClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtIpWatcher-24VDeviceClock 5 } -- wtIpWatcher-24VNetwork Group ------------------------ wtIpWatcher-24VIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtIpWatcher-24VNetwork 1 } wtIpWatcher-24VSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtIpWatcher-24VNetwork 2 } wtIpWatcher-24VGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtIpWatcher-24VNetwork 3 } wtIpWatcher-24VDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtIpWatcher-24VNetwork 4 } wtIpWatcher-24VDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtIpWatcher-24VNetwork 5 } wtIpWatcher-24VAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtIpWatcher-24VNetwork 6 } -- wtIpWatcher-24VHTTP Group -------------------------------- wtIpWatcher-24VHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtIpWatcher-24VHTTP 4 } -- wtIpWatcher-24VMail Group -------------------------------- wtIpWatcher-24VMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtIpWatcher-24VMail 1 } wtIpWatcher-24VMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtIpWatcher-24VMail 2 } wtIpWatcher-24VMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtIpWatcher-24VMail 3 } wtIpWatcher-24VMailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtIpWatcher-24VMail 4 } wtIpWatcher-24VMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtIpWatcher-24VMail 5 } wtIpWatcher-24VMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtIpWatcher-24VMail 6 } wtIpWatcher-24VMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtIpWatcher-24VMail 7 } wtIpWatcher-24VMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtIpWatcher-24VMail 8 } -- wtIpWatcher-24VSnmp Group -------------------------------- wtIpWatcher-24VSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtIpWatcher-24VSNMP 1 } wtIpWatcher-24VSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtIpWatcher-24VSNMP 2 } wtIpWatcher-24VSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtIpWatcher-24VSNMP 3 } wtIpWatcher-24VSnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtIpWatcher-24VSNMP 4 } wtIpWatcher-24VSnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtIpWatcher-24VSNMP 5 } -- wtIpWatcher-24VUDP Group -------------------------------- wtIpWatcher-24VUdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtIpWatcher-24VUDP 1 } wtIpWatcher-24VUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtIpWatcher-24VUDP 2 } wtIpWatcher-24VUdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtIpWatcher-24VUDP 3 } -- wtIpWatcher-24VSyslog Group -------------------------------- wtIpWatcher-24VSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtIpWatcher-24VSyslog 1 } wtIpWatcher-24VSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtIpWatcher-24VSyslog 2 } wtIpWatcher-24VSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtIpWatcher-24VSyslog 3 } wtIpWatcher-24VSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtIpWatcher-24VSyslog 4 } -- wtIpWatcher-24VFTP Group -------------------------------- wtIpWatcher-24VFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtIpWatcher-24VFTP 1 } wtIpWatcher-24VFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtIpWatcher-24VFTP 2 } wtIpWatcher-24VFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtIpWatcher-24VFTP 3 } wtIpWatcher-24VFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtIpWatcher-24VFTP 4 } wtIpWatcher-24VFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtIpWatcher-24VFTP 5 } wtIpWatcher-24VFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtIpWatcher-24VFTP 6 } wtIpWatcher-24VFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtIpWatcher-24VFTP 7 } -- wtIpWatcher-24VIpList Group ---------------------------- wtIpWatcher-24VIpListCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Ip addresses." ::= { wtIpWatcher-24VIpList 1 } -- IpList Interface Table wtIpWatcher-24VIpListIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcher-24VIpListIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of inices." ::= { wtIpWatcher-24VIpList 2 } wtIpWatcher-24VIpListIfEntry OBJECT-TYPE SYNTAX WtIpWatcher-24VIpListIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table entry." INDEX { wtIpWatcher-24VIpListNo } ::= { wtIpWatcher-24VIpListIfTable 1 } WtIpWatcher-24VIpListIfEntry ::= SEQUENCE { wtIpWatcher-24VIpListNo INTEGER } wtIpWatcher-24VIpListNo OBJECT-TYPE SYNTAX INTEGER (1..999) ACCESS read-only STATUS mandatory DESCRIPTION "List number of this entry." ::= { wtIpWatcher-24VIpListIfEntry 1 } -- IpList Table wtIpWatcher-24VIpListTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcher-24VIpListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of ip addresses." ::= { wtIpWatcher-24VIpList 3 } wtIpWatcher-24VIpListEntry OBJECT-TYPE SYNTAX WtIpWatcher-24VIpListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List entry." INDEX { wtIpWatcher-24VIpListNo } ::= { wtIpWatcher-24VIpListTable 1 } WtIpWatcher-24VIpListEntry ::= SEQUENCE { wtIpWatcher-24VIpListName OCTET STRING, wtIpWatcher-24VIpListPort INTEGER, wtIpWatcher-24VIpListService OCTET STRING, wtIpWatcher-24VIpListEnable OCTET STRING, wtIpWatcher-24VIpListAlias OCTET STRING } wtIpWatcher-24VIpListName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address." ::= { wtIpWatcher-24VIpListEntry 1 } wtIpWatcher-24VIpListPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number, zero in the case of broadcast or Ping." ::= { wtIpWatcher-24VIpListEntry 2 } wtIpWatcher-24VIpListService OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded scan mode, only one mode can be selected at a particular time: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Ping enable Bit 1-7: unused" ::= { wtIpWatcher-24VIpListEntry 3 } wtIpWatcher-24VIpListEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: enabled in Alarm 1 Bit 1: enabled in Alarm 2 Bit 2: enabled in Alarm 3 Bit 3: enabled in Alarm 4 Bit 4-7: unused" ::= { wtIpWatcher-24VIpListEntry 4 } wtIpWatcher-24VIpListAlias OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alias Name" ::= { wtIpWatcher-24VIpListEntry 5 } -- wtIpWatcher-24VOutputMode Group ---------------------------- wtIpWatcher-24VPowerSupplyEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Setting this enable bit turns on the intarnal 24V power supply of the outputs. All currents out must not exceed 150mA. At overcurrent condition the power supply will be shut down automatically. To reset the ocvercurrent protection circuit write 1 into wtIpWatcher-24VDiagErrorClear. Internal power supply is a feature of 57655 only. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Power Supply enable" ::= { wtIpWatcher-24VOutputMode 4 } -- wtIpWatcher-24VAlarm Group ---------------------------- wtIpWatcher-24VAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtIpWatcher-24VAlarm 1 } -- Alarm Interface Table wtIpWatcher-24VAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcher-24VAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtIpWatcher-24VAlarm 2 } wtIpWatcher-24VAlarmIfEntry OBJECT-TYPE SYNTAX WtIpWatcher-24VAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtIpWatcher-24VAlarmNo } ::= { wtIpWatcher-24VAlarmIfTable 1 } WtIpWatcher-24VAlarmIfEntry ::= SEQUENCE { wtIpWatcher-24VAlarmNo INTEGER } wtIpWatcher-24VAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtIpWatcher-24VAlarmIfEntry 1 } -- Alarm Table wtIpWatcher-24VAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcher-24VAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtIpWatcher-24VAlarm 3 } wtIpWatcher-24VAlarmEntry OBJECT-TYPE SYNTAX WtIpWatcher-24VAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtIpWatcher-24VAlarmNo } ::= { wtIpWatcher-24VAlarmTable 1 } WtIpWatcher-24VAlarmEntry ::= SEQUENCE { wtIpWatcher-24VAlarmInterval OCTET STRING, wtIpWatcher-24VAlarmEnable OCTET STRING, wtIpWatcher-24VAlarmMailAddr OCTET STRING, wtIpWatcher-24VAlarmMailSubject OCTET STRING, wtIpWatcher-24VAlarmMailText OCTET STRING, wtIpWatcher-24VAlarmSnmpManagerIP OCTET STRING, wtIpWatcher-24VAlarmSnmpTrapText OCTET STRING, wtIpWatcher-24VAlarmUdpIpAddr OCTET STRING, wtIpWatcher-24VAlarmUdpPort INTEGER, wtIpWatcher-24VAlarmUdpText OCTET STRING, wtIpWatcher-24VAlarmTcpIpAddr OCTET STRING, wtIpWatcher-24VAlarmTcpPort INTEGER, wtIpWatcher-24VAlarmTcpText OCTET STRING, wtIpWatcher-24VAlarmSyslogIpAddr OCTET STRING, wtIpWatcher-24VAlarmSyslogPort INTEGER, wtIpWatcher-24VAlarmSyslogText OCTET STRING, wtIpWatcher-24VAlarmFtpDataPort OCTET STRING, wtIpWatcher-24VAlarmFtpFileName OCTET STRING, wtIpWatcher-24VAlarmFtpText OCTET STRING, wtIpWatcher-24VAlarmFtpOption OCTET STRING, wtIpWatcher-24VAlarmTimerCron OCTET STRING, wtIpWatcher-24VAlarmMailReleaseSubject OCTET STRING, wtIpWatcher-24VAlarmMailReleaseText OCTET STRING, wtIpWatcher-24VAlarmSnmpTrapReleaseText OCTET STRING, wtIpWatcher-24VAlarmUdpReleaseText OCTET STRING, wtIpWatcher-24VAlarmTcpReleaseText OCTET STRING, wtIpWatcher-24VAlarmSyslogReleaseText OCTET STRING, wtIpWatcher-24VAlarmFtpReleaseText OCTET STRING, wtIpWatcher-24VAlarmName OCTET STRING, wtIpWatcher-24VAlarmGlobalEnable OCTET STRING, wtIpWatcher-24VAlarmCounterClear OCTET STRING, wtIpWatcher-24VAlarmAckEnable OCTET STRING, wtIpWatcher-24VAlarmAckPort INTEGER, wtIpWatcher-24VAlarmSetPort INTEGER, wtIpWatcher-24VAlarmMailTrgClearSubject OCTET STRING, wtIpWatcher-24VAlarmMailTrgClearText OCTET STRING, wtIpWatcher-24VAlarmSnmpTrapTrgClearText OCTET STRING, wtIpWatcher-24VAlarmUdpTrgClearText OCTET STRING, wtIpWatcher-24VAlarmTcpTrgClearText OCTET STRING, wtIpWatcher-24VAlarmSyslogTrgClearText OCTET STRING, wtIpWatcher-24VAlarmFtpTrgClearText OCTET STRING, wtIpWatcher-24VAlarmMailTrapTxEnable OCTET STRING, wtIpWatcher-24VAlarmSnmpTrapTrapTxEnable OCTET STRING, wtIpWatcher-24VAlarmUdpTrapTxEnable OCTET STRING, wtIpWatcher-24VAlarmTcpTrapTxEnable OCTET STRING, wtIpWatcher-24VAlarmSyslogTrapTxEnable OCTET STRING, wtIpWatcher-24VAlarmFtpTrapTxEnable OCTET STRING, wtIpWatcher-24VAlarmTriggerCount INTEGER, wtIpWatcher-24VAlarmPollingRate INTEGER } wtIpWatcher-24VAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtIpWatcher-24VAlarmEntry 5 } wtIpWatcher-24VAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused" ::= { wtIpWatcher-24VAlarmEntry 6 } wtIpWatcher-24VAlarmMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtIpWatcher-24VAlarmEntry 7 } wtIpWatcher-24VAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtIpWatcher-24VAlarmEntry 8 } wtIpWatcher-24VAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtIpWatcher-24VAlarmEntry 9 } wtIpWatcher-24VAlarmSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtIpWatcher-24VAlarmEntry 10 } wtIpWatcher-24VAlarmSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtIpWatcher-24VAlarmEntry 11 } wtIpWatcher-24VAlarmUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtIpWatcher-24VAlarmEntry 12 } wtIpWatcher-24VAlarmUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtIpWatcher-24VAlarmEntry 13 } wtIpWatcher-24VAlarmUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtIpWatcher-24VAlarmEntry 14 } wtIpWatcher-24VAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtIpWatcher-24VAlarmEntry 15 } wtIpWatcher-24VAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtIpWatcher-24VAlarmEntry 16 } wtIpWatcher-24VAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtIpWatcher-24VAlarmEntry 17 } wtIpWatcher-24VAlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtIpWatcher-24VAlarmEntry 18 } wtIpWatcher-24VAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtIpWatcher-24VAlarmEntry 19 } wtIpWatcher-24VAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtIpWatcher-24VAlarmEntry 20 } wtIpWatcher-24VAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtIpWatcher-24VAlarmEntry 21 } wtIpWatcher-24VAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtIpWatcher-24VAlarmEntry 22 } wtIpWatcher-24VAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtIpWatcher-24VAlarmEntry 23 } wtIpWatcher-24VAlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtIpWatcher-24VAlarmEntry 24 } wtIpWatcher-24VAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtIpWatcher-24VAlarmEntry 25 } wtIpWatcher-24VAlarmMailReleaseSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtIpWatcher-24VAlarmEntry 26 } wtIpWatcher-24VAlarmMailReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtIpWatcher-24VAlarmEntry 27 } wtIpWatcher-24VAlarmSnmpTrapReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtIpWatcher-24VAlarmEntry 28 } wtIpWatcher-24VAlarmUdpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtIpWatcher-24VAlarmEntry 29 } wtIpWatcher-24VAlarmTcpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtIpWatcher-24VAlarmEntry 30 } wtIpWatcher-24VAlarmSyslogReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtIpWatcher-24VAlarmEntry 31 } wtIpWatcher-24VAlarmFtpReleaseText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtIpWatcher-24VAlarmEntry 32 } wtIpWatcher-24VAlarmName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the alarm." ::= { wtIpWatcher-24VAlarmEntry 33 } wtIpWatcher-24VAlarmGlobalEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm activation: Die OCTETS werden bitweise interpretiert. Bit 0 entspricht dem LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Alarm enable" ::= { wtIpWatcher-24VAlarmEntry 34 } wtIpWatcher-24VAlarmCounterClear OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on Alarm acknowledge Bit 0 : Counter clear on Alarm send" ::= { wtIpWatcher-24VAlarmEntry 35 } wtIpWatcher-24VAlarmAckEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Software acknowledge enable Bit 0 : Hardware acknowledge enable" ::= { wtIpWatcher-24VAlarmEntry 36 } wtIpWatcher-24VAlarmAckPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of the input, which clears the alarm (1-6)." ::= { wtIpWatcher-24VAlarmEntry 37 } wtIpWatcher-24VAlarmSetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of the output, which will be set by this alarm (1-6). The configuration of pulse mode and polarity defined in the port output section is used." ::= { wtIpWatcher-24VAlarmEntry 38 } wtIpWatcher-24VAlarmMailTrgClearSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtIpWatcher-24VAlarmEntry 39 } wtIpWatcher-24VAlarmMailTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtIpWatcher-24VAlarmEntry 40 } wtIpWatcher-24VAlarmSnmpTrapTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtIpWatcher-24VAlarmEntry 41 } wtIpWatcher-24VAlarmUdpTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtIpWatcher-24VAlarmEntry 42 } wtIpWatcher-24VAlarmTcpTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtIpWatcher-24VAlarmEntry 43 } wtIpWatcher-24VAlarmSyslogTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtIpWatcher-24VAlarmEntry 44 } wtIpWatcher-24VAlarmFtpTrgClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtIpWatcher-24VAlarmEntry 45 } wtIpWatcher-24VAlarmMailTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtIpWatcher-24VAlarmEntry 46 } wtIpWatcher-24VAlarmSnmpTrapTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtIpWatcher-24VAlarmEntry 47 } wtIpWatcher-24VAlarmUdpTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtIpWatcher-24VAlarmEntry 48 } wtIpWatcher-24VAlarmTcpTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtIpWatcher-24VAlarmEntry 49 } wtIpWatcher-24VAlarmSyslogTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtIpWatcher-24VAlarmEntry 50 } wtIpWatcher-24VAlarmFtpTrapTxEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable" ::= { wtIpWatcher-24VAlarmEntry 51 } wtIpWatcher-24VAlarmTriggerCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Alarm will be send if the trigger condition occours TriggerCount times." ::= { wtIpWatcher-24VAlarmEntry 52 } wtIpWatcher-24VAlarmPollingRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds." ::= { wtIpWatcher-24VAlarmEntry 53 } -- wtIpWatcher-24VPorts Group ---------------------------- -- Input Port Table wtIpWatcher-24VInputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcher-24VInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtIpWatcher-24VPorts 1 } wtIpWatcher-24VInputPortEntry OBJECT-TYPE SYNTAX WtIpWatcher-24VInputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtIpWatcher-24VInputNo } ::= { wtIpWatcher-24VInputPortTable 1 } WtIpWatcher-24VInputPortEntry ::= SEQUENCE { wtIpWatcher-24VPortInputName OCTET STRING, wtIpWatcher-24VPortInputText OCTET STRING, wtIpWatcher-24VPortInputFilter INTEGER } wtIpWatcher-24VPortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtIpWatcher-24VInputPortEntry 1 } wtIpWatcher-24VPortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtIpWatcher-24VInputPortEntry 2 } wtIpWatcher-24VPortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtIpWatcher-24VInputPortEntry 4 } -- Output Port Table wtIpWatcher-24VOutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtIpWatcher-24VOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtIpWatcher-24VPorts 2 } wtIpWatcher-24VOutputPortEntry OBJECT-TYPE SYNTAX WtIpWatcher-24VOutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtIpWatcher-24VOutputNo } ::= { wtIpWatcher-24VOutputPortTable 1 } WtIpWatcher-24VOutputPortEntry ::= SEQUENCE { wtIpWatcher-24VPortOutputName OCTET STRING, wtIpWatcher-24VPortOutputText OCTET STRING, wtIpWatcher-24VPortPulseDuration INTEGER, wtIpWatcher-24VPortPulsePolarity OCTET STRING } wtIpWatcher-24VPortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtIpWatcher-24VOutputPortEntry 1 } wtIpWatcher-24VPortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtIpWatcher-24VOutputPortEntry 2 } wtIpWatcher-24VPortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtIpWatcher-24VOutputPortEntry 9 } wtIpWatcher-24VPortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtIpWatcher-24VPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtIpWatcher-24VOutputPortEntry 10 } -- wtIpWatcher-24VManufact Group ---------------------------- wtIpWatcher-24VMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtIpWatcher-24VManufact 1 } wtIpWatcher-24VMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtIpWatcher-24VManufact 2 } wtIpWatcher-24VMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtIpWatcher-24VManufact 3 } wtIpWatcher-24VMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtIpWatcher-24VManufact 4 } wtIpWatcher-24VMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtIpWatcher-24VManufact 5 } -- wtIpWatcher-24VDiag Group ---------------------------- wtIpWatcher-24VDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtIpWatcher-24VDiag 1 } wtIpWatcher-24VDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtIpWatcher-24VDiag 2 } wtIpWatcher-24VDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtIpWatcher-24VDiagErrorMessage. Errors are numbered from 1 to wtIpWatcher-24VDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtIpWatcher-24VDiagErrorMessage." ::= { wtIpWatcher-24VDiag 3 } wtIpWatcher-24VDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtIpWatcher-24VDiagErrorIndex as an index, the appropriate message is available." ::= { wtIpWatcher-24VDiag 4 } wtIpWatcher-24VDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtIpWatcher-24VDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtIpWatcher-24VAlert1 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtIpWatcher-24VAlert2 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtIpWatcher-24VAlert3 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtIpWatcher-24VAlert4 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtIpWatcher-24VAlert5 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtIpWatcher-24VAlert6 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtIpWatcher-24VAlert7 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtIpWatcher-24VAlert8 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtIpWatcher-24VAlert9 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 9" --#SUMMARY "Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtIpWatcher-24VAlert10 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 10" --#SUMMARY "Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtIpWatcher-24VAlert11 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 11" --#SUMMARY "Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtIpWatcher-24VAlert12 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 12" --#SUMMARY "Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtIpWatcher-24VAlert13 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtIpWatcher-24VAlert14 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtIpWatcher-24VAlert15 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtIpWatcher-24VAlert16 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtIpWatcher-24VAlert17 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtIpWatcher-24VAlert18 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtIpWatcher-24VAlert19 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtIpWatcher-24VAlert20 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtIpWatcher-24VAlert21 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 79 wtIpWatcher-24VAlert22 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 80 wtIpWatcher-24VAlert23 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtIpWatcher-24VAlert24 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText } DESCRIPTION "This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Release Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtIpWatcher-24VAlert25 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 1 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 91 wtIpWatcher-24VAlert26 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 2 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 92 wtIpWatcher-24VAlert27 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 3 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 93 wtIpWatcher-24VAlert28 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 4 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 94 wtIpWatcher-24VAlert29 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 5 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 95 wtIpWatcher-24VAlert30 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 6 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 96 wtIpWatcher-24VAlert31 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 7 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 97 wtIpWatcher-24VAlert32 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 8 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 98 wtIpWatcher-24VAlert33 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 9 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 9" --#SUMMARY "Release Alarm 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 99 wtIpWatcher-24VAlert34 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 10 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 10" --#SUMMARY "Release Alarm 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 100 wtIpWatcher-24VAlert35 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 11 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 11" --#SUMMARY "Release Alarm 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 101 wtIpWatcher-24VAlert36 TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText } DESCRIPTION "This SNMP trap is generated when the trigger of the Alarm 12 was released, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Alarm 12" --#SUMMARY "Release Alarm 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 102 wtIpWatcher-24VAlertDiag TRAP-TYPE ENTERPRISE wtIpWatcher-24V VARIABLES { wtIpWatcher-24VDiagErrorIndex, wtIpWatcher-24VDiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "IP Watcher Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- wtTrapReceiver2x2InOut Group ------------------------ wtTrapReceiver2x2Inputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent inputs." ::= { wtTrapReceiver2x2InOut 1 } wtTrapReceiver2x2Outputs OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of idependent outputs." ::= { wtTrapReceiver2x2InOut 2 } -- Input Interface Table wtTrapReceiver2x2InputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtTrapReceiver2x2InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of input indices." ::= { wtTrapReceiver2x2InOut 3 } wtTrapReceiver2x2InputEntry OBJECT-TYPE SYNTAX WtTrapReceiver2x2InputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the inputs." INDEX { wtTrapReceiver2x2InputNo } ::= { wtTrapReceiver2x2InputTable 1 } WtTrapReceiver2x2InputEntry ::= SEQUENCE { wtTrapReceiver2x2InputNo INTEGER, wtTrapReceiver2x2InputState INTEGER } wtTrapReceiver2x2InputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Index numbers of the inputs." ::= { wtTrapReceiver2x2InputEntry 1 } wtTrapReceiver2x2InputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of a single input bit, 0-OFF, 1-ON." ::= { wtTrapReceiver2x2InputEntry 4 } wtTrapReceiver2x2InputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1" ::= { wtTrapReceiver2x2InOut 4 } -- Output Interface Table wtTrapReceiver2x2OutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtTrapReceiver2x2OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of output indices." ::= { wtTrapReceiver2x2InOut 5 } wtTrapReceiver2x2OutputEntry OBJECT-TYPE SYNTAX WtTrapReceiver2x2OutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the outputs." INDEX { wtTrapReceiver2x2OutputNo } ::= { wtTrapReceiver2x2OutputTable 1 } WtTrapReceiver2x2OutputEntry ::= SEQUENCE { wtTrapReceiver2x2OutputNo INTEGER, wtTrapReceiver2x2OutputState INTEGER } wtTrapReceiver2x2OutputNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Output number." ::= { wtTrapReceiver2x2OutputEntry 1 } wtTrapReceiver2x2OutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of a single output bit, 0-OFF, 1-ON." ::= { wtTrapReceiver2x2OutputEntry 2 } wtTrapReceiver2x2OutputValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to read the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt" ::= { wtTrapReceiver2x2InOut 6 } -- Action Output Interface Table wtTrapReceiver2x2ActionOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF WtTrapReceiver2x2ActionOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices.." ::= { wtTrapReceiver2x2InOut 8 } wtTrapReceiver2x2ActionOutputEntry OBJECT-TYPE SYNTAX WtTrapReceiver2x2ActionOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Index reference." INDEX { wtTrapReceiver2x2ActionNo } ::= { wtTrapReceiver2x2ActionOutputTable 1 } WtTrapReceiver2x2ActionOutputEntry ::= SEQUENCE { wtTrapReceiver2x2ActionOutputState INTEGER, wtTrapReceiver2x2ActionTriggerState INTEGER } wtTrapReceiver2x2ActionOutputState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "State of the alarm, 0-OFF, 1-ON." ::= { wtTrapReceiver2x2ActionOutputEntry 1 } wtTrapReceiver2x2ActionTriggerState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "State of the trigger condition, 0-OFF, 1-ON." ::= { wtTrapReceiver2x2ActionOutputEntry 2 } -- SystemTimer Interface Table wtTrapReceiver2x2SystemTimerTable OBJECT-TYPE SYNTAX SEQUENCE OF WtTrapReceiver2x2SystemTimerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of system timer." ::= { wtTrapReceiver2x2InOut 9 } wtTrapReceiver2x2SystemTimerEntry OBJECT-TYPE SYNTAX WtTrapReceiver2x2SystemTimerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the system timer." INDEX { wtTrapReceiver2x2SystemTimerNo } ::= { wtTrapReceiver2x2SystemTimerTable 1 } WtTrapReceiver2x2SystemTimerEntry ::= SEQUENCE { wtTrapReceiver2x2SystemTimerNo INTEGER } wtTrapReceiver2x2SystemTimerNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Index number of the system timer." ::= { wtTrapReceiver2x2SystemTimerEntry 1 } -- Button Interface Table wtTrapReceiver2x2ButtonTable OBJECT-TYPE SYNTAX SEQUENCE OF WtTrapReceiver2x2ButtonEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of buttons." ::= { wtTrapReceiver2x2InOut 10 } wtTrapReceiver2x2ButtonEntry OBJECT-TYPE SYNTAX WtTrapReceiver2x2ButtonEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Number of the button." INDEX { wtTrapReceiver2x2ButtonNo } ::= { wtTrapReceiver2x2ButtonTable 1 } WtTrapReceiver2x2ButtonEntry ::= SEQUENCE { wtTrapReceiver2x2ButtonNo INTEGER } wtTrapReceiver2x2ButtonNo OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Index numder of the button." ::= { wtTrapReceiver2x2ButtonEntry 1 } -- wtTrapReceiver2x2SessCntrl Group -------------------------------- wtTrapReceiver2x2SessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtTrapReceiver2x2SessCntrlLogout. When read this variable provides a string of length zero." ::= { wtTrapReceiver2x2SessCntrl 1 } wtTrapReceiver2x2SessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtTrapReceiver2x2SessCntrl 2 } wtTrapReceiver2x2SessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtTrapReceiver2x2SessCntrl 3 } wtTrapReceiver2x2SessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtTrapReceiver2x2SessCntrl 4 } wtTrapReceiver2x2SessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtTrapReceiver2x2SessCntrl 5 } -- wtTrapReceiver2x2Text Group ------------------------ wtTrapReceiver2x2DeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtTrapReceiver2x2Text 1 } wtTrapReceiver2x2DeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtTrapReceiver2x2Text 2 } wtTrapReceiver2x2DeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtTrapReceiver2x2Text 3 } wtTrapReceiver2x2DeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtTrapReceiver2x2Text 4 } -- wtTrapReceiver2x2TimeZone Group ---------------------------- wtTrapReceiver2x2TzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtTrapReceiver2x2TimeZone 1 } wtTrapReceiver2x2TzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtTrapReceiver2x2TimeZone 2 } wtTrapReceiver2x2TzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtTrapReceiver2x2TimeZone 3 } wtTrapReceiver2x2StTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtTrapReceiver2x2TimeZone 4 } wtTrapReceiver2x2StTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtTrapReceiver2x2TimeZone 5 } wtTrapReceiver2x2StTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtTrapReceiver2x2TimeZone 6 } wtTrapReceiver2x2StTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtTrapReceiver2x2StartMonth-January(1), wtTrapReceiver2x2StartMonth-February(2), wtTrapReceiver2x2StartMonth-March(3), wtTrapReceiver2x2StartMonth-April(4), wtTrapReceiver2x2StartMonth-May(5), wtTrapReceiver2x2StartMonth-June(6), wtTrapReceiver2x2StartMonth-July(7), wtTrapReceiver2x2StartMonth-August(8), wtTrapReceiver2x2StartMonth-September(9), wtTrapReceiver2x2StartMonth-October(10), wtTrapReceiver2x2StartMonth-November(11), wtTrapReceiver2x2StartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtTrapReceiver2x2TimeZone 7 } wtTrapReceiver2x2StTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtTrapReceiver2x2StartMode-first(1), wtTrapReceiver2x2StartMode-second(2), wtTrapReceiver2x2StartMode-third(3), wtTrapReceiver2x2StartMode-fourth(4), wtTrapReceiver2x2StartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtTrapReceiver2x2TimeZone 8 } wtTrapReceiver2x2StTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtTrapReceiver2x2StartWday-Sunday(1), wtTrapReceiver2x2StartWday-Monday(2), wtTrapReceiver2x2StartWday-Tuesday(3), wtTrapReceiver2x2StartWday-Thursday(4), wtTrapReceiver2x2StartWday-Wednesday(5), wtTrapReceiver2x2StartWday-Friday(6), wtTrapReceiver2x2StartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtTrapReceiver2x2TimeZone 9 } wtTrapReceiver2x2StTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtTrapReceiver2x2TimeZone 10 } wtTrapReceiver2x2StTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtTrapReceiver2x2TimeZone 11 } wtTrapReceiver2x2StTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtTrapReceiver2x2StopMonth-January(1), wtTrapReceiver2x2StopMonth-February(2), wtTrapReceiver2x2StopMonth-March(3), wtTrapReceiver2x2StopMonth-April(4), wtTrapReceiver2x2StopMonth-May(5), wtTrapReceiver2x2StopMonth-June(6), wtTrapReceiver2x2StopMonth-July(7), wtTrapReceiver2x2StopMonth-August(8), wtTrapReceiver2x2StopMonth-September(9), wtTrapReceiver2x2StopMonth-October(10), wtTrapReceiver2x2StopMonth-November(11), wtTrapReceiver2x2StopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtTrapReceiver2x2TimeZone 12 } wtTrapReceiver2x2StTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtTrapReceiver2x2StopMode-first(1), wtTrapReceiver2x2StopMode-second(2), wtTrapReceiver2x2StopMode-third(3), wtTrapReceiver2x2StopMode-fourth(4), wtTrapReceiver2x2StopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtTrapReceiver2x2TimeZone 13 } wtTrapReceiver2x2StTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtTrapReceiver2x2StopWday-Sunday(1), wtTrapReceiver2x2StopWday-Monday(2), wtTrapReceiver2x2StopWday-Tuesday(3), wtTrapReceiver2x2StopWday-Thursday(4), wtTrapReceiver2x2StopWday-Wednesday(5), wtTrapReceiver2x2StopWday-Friday(6), wtTrapReceiver2x2StopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtTrapReceiver2x2TimeZone 14 } wtTrapReceiver2x2StTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtTrapReceiver2x2TimeZone 15 } wtTrapReceiver2x2StTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtTrapReceiver2x2TimeZone 16 } -- wtTrapReceiver2x2TimeServer Group ---------------------------- wtTrapReceiver2x2TimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtTrapReceiver2x2TimeServer 1 } wtTrapReceiver2x2TimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtTrapReceiver2x2TimeServer 2 } wtTrapReceiver2x2TsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtTrapReceiver2x2TimeServer 3 } wtTrapReceiver2x2TsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtTrapReceiver2x2TimeServer 4 } -- wtTrapReceiver2x2DeviceClock Group ---------------------------- wtTrapReceiver2x2ClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtTrapReceiver2x2DeviceClock 1 } wtTrapReceiver2x2ClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtTrapReceiver2x2DeviceClock 2 } wtTrapReceiver2x2ClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtTrapReceiver2x2DeviceClock 3 } wtTrapReceiver2x2ClockMonth OBJECT-TYPE SYNTAX INTEGER { wtTrapReceiver2x2ClockMonth-January(1), wtTrapReceiver2x2ClockMonth-February(2), wtTrapReceiver2x2ClockMonth-March(3), wtTrapReceiver2x2ClockMonth-April(4), wtTrapReceiver2x2ClockMonth-May(5), wtTrapReceiver2x2ClockMonth-June(6), wtTrapReceiver2x2ClockMonth-July(7), wtTrapReceiver2x2ClockMonth-August(8), wtTrapReceiver2x2ClockMonth-September(9), wtTrapReceiver2x2ClockMonth-October(10), wtTrapReceiver2x2ClockMonth-November(11), wtTrapReceiver2x2ClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtTrapReceiver2x2DeviceClock 4 } wtTrapReceiver2x2ClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtTrapReceiver2x2DeviceClock 5 } -- wtTrapReceiver2x2Network Group ------------------------ wtTrapReceiver2x2IpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtTrapReceiver2x2Network 1 } wtTrapReceiver2x2SubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtTrapReceiver2x2Network 2 } wtTrapReceiver2x2Gateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtTrapReceiver2x2Network 3 } wtTrapReceiver2x2DnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtTrapReceiver2x2Network 4 } wtTrapReceiver2x2DnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtTrapReceiver2x2Network 5 } wtTrapReceiver2x2AddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable" ::= { wtTrapReceiver2x2Network 6 } -- wtTrapReceiver2x2HTTP Group -------------------------------- wtTrapReceiver2x2HttpPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtTrapReceiver2x2HTTP 4 } -- wtTrapReceiver2x2Mail Group -------------------------------- wtTrapReceiver2x2MailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtTrapReceiver2x2Mail 1 } wtTrapReceiver2x2MailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtTrapReceiver2x2Mail 2 } wtTrapReceiver2x2MailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtTrapReceiver2x2Mail 3 } wtTrapReceiver2x2MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtTrapReceiver2x2Mail 4 } wtTrapReceiver2x2MailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtTrapReceiver2x2Mail 5 } wtTrapReceiver2x2MailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtTrapReceiver2x2Mail 6 } wtTrapReceiver2x2MailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtTrapReceiver2x2Mail 7 } wtTrapReceiver2x2MailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtTrapReceiver2x2Mail 8 } -- wtTrapReceiver2x2Snmp Group -------------------------------- wtTrapReceiver2x2SnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtTrapReceiver2x2SNMP 1 } wtTrapReceiver2x2SnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtTrapReceiver2x2SNMP 2 } wtTrapReceiver2x2SnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtTrapReceiver2x2SNMP 3 } wtTrapReceiver2x2SnmpSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtTrapReceiver2x2SNMP 4 } wtTrapReceiver2x2SnmpSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused" ::= { wtTrapReceiver2x2SNMP 5 } -- wtTrapReceiver2x2UDP Group -------------------------------- wtTrapReceiver2x2UdpAdminPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtTrapReceiver2x2UDP 1 } wtTrapReceiver2x2UdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtTrapReceiver2x2UDP 2 } wtTrapReceiver2x2UdpRemotePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value." ::= { wtTrapReceiver2x2UDP 3 } -- wtTrapReceiver2x2Syslog Group -------------------------------- wtTrapReceiver2x2SyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtTrapReceiver2x2Syslog 1 } wtTrapReceiver2x2SyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtTrapReceiver2x2Syslog 2 } wtTrapReceiver2x2SyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtTrapReceiver2x2Syslog 3 } wtTrapReceiver2x2SyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtTrapReceiver2x2Syslog 4 } -- wtTrapReceiver2x2FTP Group -------------------------------- wtTrapReceiver2x2FTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtTrapReceiver2x2FTP 1 } wtTrapReceiver2x2FTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtTrapReceiver2x2FTP 2 } wtTrapReceiver2x2FTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtTrapReceiver2x2FTP 3 } wtTrapReceiver2x2FTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtTrapReceiver2x2FTP 4 } wtTrapReceiver2x2FTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtTrapReceiver2x2FTP 5 } wtTrapReceiver2x2FTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtTrapReceiver2x2FTP 6 } wtTrapReceiver2x2FTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtTrapReceiver2x2FTP 7 } -- wtTrapReceiver2x2WatchList Group ---------------------------- wtTrapReceiver2x2WatchListCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Ip addresses." ::= { wtTrapReceiver2x2WatchList 1 } -- WatchList Interface Table wtTrapReceiver2x2WatchListIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtTrapReceiver2x2WatchListIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of inices." ::= { wtTrapReceiver2x2WatchList 2 } wtTrapReceiver2x2WatchListIfEntry OBJECT-TYPE SYNTAX WtTrapReceiver2x2WatchListIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table entry." INDEX { wtTrapReceiver2x2WatchListNo } ::= { wtTrapReceiver2x2WatchListIfTable 1 } WtTrapReceiver2x2WatchListIfEntry ::= SEQUENCE { wtTrapReceiver2x2WatchListNo INTEGER } wtTrapReceiver2x2WatchListNo OBJECT-TYPE SYNTAX INTEGER (1..999) ACCESS read-only STATUS mandatory DESCRIPTION "List number of this entry." ::= { wtTrapReceiver2x2WatchListIfEntry 1 } -- WatchList Table wtTrapReceiver2x2WatchListTable OBJECT-TYPE SYNTAX SEQUENCE OF WtTrapReceiver2x2WatchListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of ip addresses." ::= { wtTrapReceiver2x2WatchList 3 } wtTrapReceiver2x2WatchListEntry OBJECT-TYPE SYNTAX WtTrapReceiver2x2WatchListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List entry." INDEX { wtTrapReceiver2x2WatchListNo } ::= { wtTrapReceiver2x2WatchListTable 1 } WtTrapReceiver2x2WatchListEntry ::= SEQUENCE { wtTrapReceiver2x2WatchListName OCTET STRING, wtTrapReceiver2x2WatchListPort INTEGER, wtTrapReceiver2x2WatchListService OCTET STRING, wtTrapReceiver2x2WatchListEnable OCTET STRING, wtTrapReceiver2x2WatchListAlias OCTET STRING, wtTrapReceiver2x2WatchListTrapNo INTEGER, wtTrapReceiver2x2WatchListSpecificNo INTEGER, wtTrapReceiver2x2WatchListFacility INTEGER, wtTrapReceiver2x2WatchListSeverity INTEGER } wtTrapReceiver2x2WatchListName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address." ::= { wtTrapReceiver2x2WatchListEntry 1 } wtTrapReceiver2x2WatchListPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number, zero in the case of broadcast or Ping." ::= { wtTrapReceiver2x2WatchListEntry 2 } wtTrapReceiver2x2WatchListService OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded scan mode, only one mode can be selected at a particular time: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: unused Bit 1: unused Bit 2: SNMP Trap reveive enable Bit 3: Syslog receive enable Bit 4-7: unused" ::= { wtTrapReceiver2x2WatchListEntry 3 } wtTrapReceiver2x2WatchListEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: Bit 0: enabled in Report 9 Bit 1: enabled in Report 10 Bit 2: enabled in Report 11 Bit 3: enabled in Report 12 Bit 4-7: unused Octet 4: Bit 0: enabled in Report 1 Bit 1: enabled in Report 2 Bit 2: enabled in Report 3 Bit 3: enabled in Report 4 Bit 4: enabled in Report 5 Bit 5: enabled in Report 6 Bit 6: enabled in Report 7 Bit 7: enabled in Report 8" ::= { wtTrapReceiver2x2WatchListEntry 4 } wtTrapReceiver2x2WatchListAlias OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alias Name" ::= { wtTrapReceiver2x2WatchListEntry 5 } wtTrapReceiver2x2WatchListTrapNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Trap No: this filter is only active, if SNMP Trap reveive enable in wtTrapReceiver2x2WatchListService is set. wtTrapReceiver2x2WatchListTrapNo-ColdStart(0), wtTrapReceiver2x2WatchListTrapNo-WarmStart(1), wtTrapReceiver2x2WatchListTrapNo-LinkDown(2), wtTrapReceiver2x2WatchListTrapNo-LinkUp(3), wtTrapReceiver2x2WatchListTrapNo-AuthFailure(4), wtTrapReceiver2x2WatchListTrapNo-EPGneighborLoss(5), wtTrapReceiver2x2WatchListTrapNo-EnterpriseSpecific(6), wtTrapReceiver2x2WatchListTrapNo-WildCard(7)" ::= { wtTrapReceiver2x2WatchListEntry 6 } wtTrapReceiver2x2WatchListSpecificNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Specific No: this filter is only active, if SNMP Trap reveive enable in wtTrapReceiver2x2WatchListService is set." ::= { wtTrapReceiver2x2WatchListEntry 7 } wtTrapReceiver2x2WatchListFacility OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Syslog message level Facility: this filter is only active, if Syslog receive enable in wtTrapReceiver2x2WatchListService is set. wtTrapReceiver2x2WatchListFacility-Emergency(0), wtTrapReceiver2x2WatchListFacility-Alert(1), wtTrapReceiver2x2WatchListFacility-Critical(2), wtTrapReceiver2x2WatchListFacility-Error(3), wtTrapReceiver2x2WatchListFacility-Warning(4), wtTrapReceiver2x2WatchListFacility-Notice(5), wtTrapReceiver2x2WatchListFacility-Informational(6), wtTrapReceiver2x2WatchListFacility-Debug(7), wtTrapReceiver2x2WatchListFacility-WildCard(8)" ::= { wtTrapReceiver2x2WatchListEntry 8 } wtTrapReceiver2x2WatchListSeverity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Syslog message level Severity: this filter is only active, if Syslog receive enable in wtTrapReceiver2x2WatchListService is set. wtTrapReceiver2x2WatchListSeverity-kernel-messages(0), wtTrapReceiver2x2WatchListSeverity-user-level-messages(1), wtTrapReceiver2x2WatchListSeverity-mail-system(2), wtTrapReceiver2x2WatchListSeverity-system-daemons(3), wtTrapReceiver2x2WatchListSeverity-security-auth-messages(4), wtTrapReceiver2x2WatchListSeverity-msg-generated-by-syslogd(5), wtTrapReceiver2x2WatchListSeverity-line-printer-subsystem(6), wtTrapReceiver2x2WatchListSeverity-network-news-subsystem(7), wtTrapReceiver2x2WatchListSeverity-UUCP-subsystem(8), wtTrapReceiver2x2WatchListSeverity-clock-daemon(9), wtTrapReceiver2x2WatchListSeverity-security-auth-msg-private(10), wtTrapReceiver2x2WatchListSeverity-FTP-daemon(11), wtTrapReceiver2x2WatchListSeverity-NTP-subsystem(12), wtTrapReceiver2x2WatchListSeverity-log-audit(13), wtTrapReceiver2x2WatchListSeverity-log-alert(14), wtTrapReceiver2x2WatchListSeverity-clock-daemon-15(15), wtTrapReceiver2x2WatchListSeverity-local0(16), wtTrapReceiver2x2WatchListSeverity-local1(17), wtTrapReceiver2x2WatchListSeverity-local2(18), wtTrapReceiver2x2WatchListSeverity-local3(19), wtTrapReceiver2x2WatchListSeverity-local4(20), wtTrapReceiver2x2WatchListSeverity-local5(21), wtTrapReceiver2x2WatchListSeverity-local6(22), wtTrapReceiver2x2WatchListSeverity-local7(23), wtTrapReceiver2x2WatchListSeverity-WildCard(24) " ::= { wtTrapReceiver2x2WatchListEntry 9 } -- wtTrapReceiver2x2OutputMode Group ---------------------------- wtTrapReceiver2x2PowerSupplyEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Setting this enable bit turns on the intarnal 24V power supply of the outputs. All currents out must not exceed 150mA. At overcurrent condition the power supply will be shut down automatically. To reset the ocvercurrent protection circuit write 1 into wtTrapReceiver2x2DiagErrorClear. Internal power supply is a feature of 57655 only. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Power Supply enable" ::= { wtTrapReceiver2x2OutputMode 4 } -- wtTrapReceiver2x2Action Group ---------------------------- wtTrapReceiver2x2ActionCount OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtTrapReceiver2x2Action 1 } -- Action Interface Table wtTrapReceiver2x2ActionIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtTrapReceiver2x2ActionIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtTrapReceiver2x2Action 2 } wtTrapReceiver2x2ActionIfEntry OBJECT-TYPE SYNTAX WtTrapReceiver2x2ActionIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtTrapReceiver2x2ActionNo } ::= { wtTrapReceiver2x2ActionIfTable 1 } WtTrapReceiver2x2ActionIfEntry ::= SEQUENCE { wtTrapReceiver2x2ActionNo INTEGER } wtTrapReceiver2x2ActionNo OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Numbers of the alarms." ::= { wtTrapReceiver2x2ActionIfEntry 1 } -- Action Table wtTrapReceiver2x2ActionTable OBJECT-TYPE SYNTAX SEQUENCE OF WtTrapReceiver2x2ActionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtTrapReceiver2x2Action 3 } wtTrapReceiver2x2ActionEntry OBJECT-TYPE SYNTAX WtTrapReceiver2x2ActionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Action parameters of the individual alarms." INDEX { wtTrapReceiver2x2ActionNo } ::= { wtTrapReceiver2x2ActionTable 1 } WtTrapReceiver2x2ActionEntry ::= SEQUENCE { wtTrapReceiver2x2ActionInputTrigger OCTET STRING, wtTrapReceiver2x2ActionInterval OCTET STRING, wtTrapReceiver2x2ActionEnable OCTET STRING, wtTrapReceiver2x2ActionMailAddr OCTET STRING, wtTrapReceiver2x2ActionMailSubject OCTET STRING, wtTrapReceiver2x2ActionMailText OCTET STRING, wtTrapReceiver2x2ActionSnmpManagerIP OCTET STRING, wtTrapReceiver2x2ActionSnmpTrapText OCTET STRING, wtTrapReceiver2x2ActionUdpIpAddr OCTET STRING, wtTrapReceiver2x2ActionUdpPort INTEGER, wtTrapReceiver2x2ActionUdpText OCTET STRING, wtTrapReceiver2x2ActionTcpIpAddr OCTET STRING, wtTrapReceiver2x2ActionTcpPort INTEGER, wtTrapReceiver2x2ActionTcpText OCTET STRING, wtTrapReceiver2x2ActionSyslogIpAddr OCTET STRING, wtTrapReceiver2x2ActionSyslogPort INTEGER, wtTrapReceiver2x2ActionSyslogText OCTET STRING, wtTrapReceiver2x2ActionFtpDataPort OCTET STRING, wtTrapReceiver2x2ActionFtpFileName OCTET STRING, wtTrapReceiver2x2ActionFtpText OCTET STRING, wtTrapReceiver2x2ActionFtpOption OCTET STRING, wtTrapReceiver2x2ActionTimerCron OCTET STRING, wtTrapReceiver2x2ActionName OCTET STRING, wtTrapReceiver2x2ActionGlobalEnable OCTET STRING, wtTrapReceiver2x2ActionSystemTimerTrigger OCTET STRING, wtTrapReceiver2x2ActionSystemButtonTrigger OCTET STRING, wtTrapReceiver2x2ActionOutputAction OCTET STRING } wtTrapReceiver2x2ActionInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0: Input 0 falling edge Bit 1: Input 0 rising edge Bit 2: Input 1 falling edge Bit 3: Input 1 rising edge Bit 4-7: unused" ::= { wtTrapReceiver2x2ActionEntry 1 } wtTrapReceiver2x2ActionInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtTrapReceiver2x2ActionEntry 5 } wtTrapReceiver2x2ActionEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused" ::= { wtTrapReceiver2x2ActionEntry 6 } wtTrapReceiver2x2ActionMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtTrapReceiver2x2ActionEntry 7 } wtTrapReceiver2x2ActionMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtTrapReceiver2x2ActionEntry 8 } wtTrapReceiver2x2ActionMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Action mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual" ::= { wtTrapReceiver2x2ActionEntry 9 } wtTrapReceiver2x2ActionSnmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtTrapReceiver2x2ActionEntry 10 } wtTrapReceiver2x2ActionSnmpTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the trap body." ::= { wtTrapReceiver2x2ActionEntry 11 } wtTrapReceiver2x2ActionUdpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the UDP listener to which the Webio device should send UDP traps." ::= { wtTrapReceiver2x2ActionEntry 12 } wtTrapReceiver2x2ActionUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the UDP listener to which the Webio device should send UDP traps." ::= { wtTrapReceiver2x2ActionEntry 13 } wtTrapReceiver2x2ActionUdpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the UDP trap body." ::= { wtTrapReceiver2x2ActionEntry 14 } wtTrapReceiver2x2ActionTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the TCP listener to which the Webio device should send TCP traps." ::= { wtTrapReceiver2x2ActionEntry 15 } wtTrapReceiver2x2ActionTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP listener to which the Webio device should send TCP traps." ::= { wtTrapReceiver2x2ActionEntry 16 } wtTrapReceiver2x2ActionTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text appears in the TCP trap body." ::= { wtTrapReceiver2x2ActionEntry 17 } wtTrapReceiver2x2ActionSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtTrapReceiver2x2ActionEntry 18 } wtTrapReceiver2x2ActionSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtTrapReceiver2x2ActionEntry 19 } wtTrapReceiver2x2ActionSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtTrapReceiver2x2ActionEntry 20 } wtTrapReceiver2x2ActionFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtTrapReceiver2x2ActionEntry 21 } wtTrapReceiver2x2ActionFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtTrapReceiver2x2ActionEntry 22 } wtTrapReceiver2x2ActionFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtTrapReceiver2x2ActionEntry 23 } wtTrapReceiver2x2ActionFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtTrapReceiver2x2ActionEntry 24 } wtTrapReceiver2x2ActionTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 10 space or tab seperated text fields defining a time window for sending time triggered messages. 2 CRON time for start time and stop time are defined as follows: Start time: field 1: Minutes Range 0-59 3. Hours Range 0-23, 0 is midnight 5: Day of month Range 1-31 7: Month Range 1-12 9: Weekday Range 0-6, 0 is sunday Stop time: field 2: Minutes Range 0-59 4. Hours Range 0-23, 0 is midnight 6: Day of month Range 1-31 8: Month Range 1-12 10: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtTrapReceiver2x2ActionEntry 25 } wtTrapReceiver2x2ActionName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the alarm." ::= { wtTrapReceiver2x2ActionEntry 33 } wtTrapReceiver2x2ActionGlobalEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm activation: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Action enable" ::= { wtTrapReceiver2x2ActionEntry 34 } wtTrapReceiver2x2ActionSystemTimerTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded system timer activation: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0: System Timer 1 enable Bit 1: System Timer 2 enable Bit 2-7: unused" ::= { wtTrapReceiver2x2ActionEntry 55 } wtTrapReceiver2x2ActionSystemButtonTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded button activation: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0: Button 1 enable Bit 1: Button 2 enable Bit 2: Button 3 enable Bit 3: Button 4 enable Bit 3: Button 5 enable Bit 3: Button 6 enable Bit 3: Button 7 enable Bit 3: Button 8 enable." ::= { wtTrapReceiver2x2ActionEntry 56 } wtTrapReceiver2x2ActionOutputAction OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows setting of individual output. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1 OCTETS 9-12 contain the TOOGLE bit (1=ON, 0=OFF). outputs masked with the TOGGLE bit trigger change their state on every action. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: TOGGLE bits of digital outputs 0-1" ::= { wtTrapReceiver2x2ActionEntry 57 } -- wtTrapReceiver2x2InEvSystemTimer Group ---------------------------- -- SystemTimer Table wtTrapReceiver2x2SystemTimerPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtTrapReceiver2x2SystemTimerPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the SystemTimer number." ::= { wtTrapReceiver2x2InEvSystemTimer 1 } wtTrapReceiver2x2SystemTimerPortEntry OBJECT-TYPE SYNTAX WtTrapReceiver2x2SystemTimerPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SystemTimer parameter for the individual SystemTimer." INDEX { wtTrapReceiver2x2SystemTimerNo } ::= { wtTrapReceiver2x2SystemTimerPortTable 1 } WtTrapReceiver2x2SystemTimerPortEntry ::= SEQUENCE { wtTrapReceiver2x2PortSystemTimerEnable OCTET STRING, wtTrapReceiver2x2PortSystemTimerName OCTET STRING, wtTrapReceiver2x2PortSystemTimerCron OCTET STRING } wtTrapReceiver2x2PortSystemTimerEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded SystemTimer enable: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: ungenutzt OCTET 2: ungenutzt OCTET 3: ungenutzt OCTET 4, Bit 1-7: ungenutzt Bit 0 : SystemTimer enable" ::= { wtTrapReceiver2x2SystemTimerPortEntry 1 } wtTrapReceiver2x2PortSystemTimerName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the SystemTimer." ::= { wtTrapReceiver2x2SystemTimerPortEntry 2 } wtTrapReceiver2x2PortSystemTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtTrapReceiver2x2SystemTimerPortEntry 3 } -- wtTrapReceiver2x2InEvButtons Group ---------------------------- -- Button Table wtTrapReceiver2x2ButtonPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtTrapReceiver2x2ButtonPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the button number." ::= { wtTrapReceiver2x2InEvButtons 1 } wtTrapReceiver2x2ButtonPortEntry OBJECT-TYPE SYNTAX WtTrapReceiver2x2ButtonPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Button parameter for the individual buttons." INDEX { wtTrapReceiver2x2ButtonNo } ::= { wtTrapReceiver2x2ButtonPortTable 1 } WtTrapReceiver2x2ButtonPortEntry ::= SEQUENCE { wtTrapReceiver2x2PortButtonEnable OCTET STRING, wtTrapReceiver2x2PortButtonName OCTET STRING, wtTrapReceiver2x2PortButtonText OCTET STRING, wtTrapReceiver2x2PortButtonAccess OCTET STRING } wtTrapReceiver2x2PortButtonEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded button enable: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: ungenutzt OCTET 2: ungenutzt OCTET 3: ungenutzt OCTET 4, Bit 1-7: ungenutzt Bit 0 : Button enable" ::= { wtTrapReceiver2x2ButtonPortEntry 1 } wtTrapReceiver2x2PortButtonName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the button." ::= { wtTrapReceiver2x2ButtonPortEntry 2 } wtTrapReceiver2x2PortButtonText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the button." ::= { wtTrapReceiver2x2ButtonPortEntry 3 } wtTrapReceiver2x2PortButtonAccess OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded button access level: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 3-7: unused Bit 2 : For user administrator visible and operable Bit 1 : For user operator visible and operable Bit 0 : For user guest visible and operable" ::= { wtTrapReceiver2x2ButtonPortEntry 4 } -- wtTrapReceiver2x2InEvInputs Group ---------------------------- -- Input Port Table wtTrapReceiver2x2InputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtTrapReceiver2x2InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the input number." ::= { wtTrapReceiver2x2InEvInputs 1 } wtTrapReceiver2x2InputPortEntry OBJECT-TYPE SYNTAX WtTrapReceiver2x2InputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input parameter for the individual inputs." INDEX { wtTrapReceiver2x2InputNo } ::= { wtTrapReceiver2x2InputPortTable 1 } WtTrapReceiver2x2InputPortEntry ::= SEQUENCE { wtTrapReceiver2x2PortInputName OCTET STRING, wtTrapReceiver2x2PortInputText OCTET STRING, wtTrapReceiver2x2PortInputFilter INTEGER } wtTrapReceiver2x2PortInputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the input." ::= { wtTrapReceiver2x2InputPortEntry 1 } wtTrapReceiver2x2PortInputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the input." ::= { wtTrapReceiver2x2InputPortEntry 2 } wtTrapReceiver2x2PortInputFilter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored." ::= { wtTrapReceiver2x2InputPortEntry 4 } -- wtTrapReceiver2x2OutEvOutputs Group wtTrapReceiver2x2OutputPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtTrapReceiver2x2OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the output number." ::= { wtTrapReceiver2x2OutEvOutputs 1 } wtTrapReceiver2x2OutputPortEntry OBJECT-TYPE SYNTAX WtTrapReceiver2x2OutputPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output parameters of the individual outputs." INDEX { wtTrapReceiver2x2OutputNo } ::= { wtTrapReceiver2x2OutputPortTable 1 } WtTrapReceiver2x2OutputPortEntry ::= SEQUENCE { wtTrapReceiver2x2PortOutputName OCTET STRING, wtTrapReceiver2x2PortOutputText OCTET STRING, wtTrapReceiver2x2PortPulseDuration INTEGER, wtTrapReceiver2x2PortPulsePolarity OCTET STRING } wtTrapReceiver2x2PortOutputName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the output." ::= { wtTrapReceiver2x2OutputPortEntry 1 } wtTrapReceiver2x2PortOutputText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the output." ::= { wtTrapReceiver2x2OutputPortEntry 2 } wtTrapReceiver2x2PortPulseDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output." ::= { wtTrapReceiver2x2OutputPortEntry 9 } wtTrapReceiver2x2PortPulsePolarity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the polarity of the output pulse, if wtTrapReceiver2x2PortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused" ::= { wtTrapReceiver2x2OutputPortEntry 10 } -- wtTrapReceiver2x2Manufact Group ---------------------------- wtTrapReceiver2x2MfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtTrapReceiver2x2Manufact 1 } wtTrapReceiver2x2MfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtTrapReceiver2x2Manufact 2 } wtTrapReceiver2x2MfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtTrapReceiver2x2Manufact 3 } wtTrapReceiver2x2MfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtTrapReceiver2x2Manufact 4 } wtTrapReceiver2x2MfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtTrapReceiver2x2Manufact 5 } -- wtTrapReceiver2x2Diag Group ---------------------------- wtTrapReceiver2x2DiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtTrapReceiver2x2Diag 1 } wtTrapReceiver2x2DiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtTrapReceiver2x2Diag 2 } wtTrapReceiver2x2DiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtTrapReceiver2x2DiagErrorMessage. Errors are numbered from 1 to wtTrapReceiver2x2DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtTrapReceiver2x2DiagErrorMessage." ::= { wtTrapReceiver2x2Diag 3 } wtTrapReceiver2x2DiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtTrapReceiver2x2DiagErrorIndex as an index, the appropriate message is available." ::= { wtTrapReceiver2x2Diag 4 } wtTrapReceiver2x2DiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtTrapReceiver2x2Diag 5 } -- TRAP DEFINITIONS -- These SNMP traps will be send, if the appropriate trigger condition match wtTrapReceiver2x2Alert1 TRAP-TYPE ENTERPRISE wtTrapReceiver2x2 VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Action 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Trap-Receiver Action 1" --#SUMMARY "Action 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 41 wtTrapReceiver2x2Alert2 TRAP-TYPE ENTERPRISE wtTrapReceiver2x2 VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Action 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Trap-Receiver Action 2" --#SUMMARY "Action 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 42 wtTrapReceiver2x2Alert3 TRAP-TYPE ENTERPRISE wtTrapReceiver2x2 VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Action 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Trap-Receiver Action 3" --#SUMMARY "Action 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 43 wtTrapReceiver2x2Alert4 TRAP-TYPE ENTERPRISE wtTrapReceiver2x2 VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Action 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Trap-Receiver Action 4" --#SUMMARY "Action 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 44 wtTrapReceiver2x2Alert5 TRAP-TYPE ENTERPRISE wtTrapReceiver2x2 VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Action 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Trap-Receiver Action 5" --#SUMMARY "Action 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 45 wtTrapReceiver2x2Alert6 TRAP-TYPE ENTERPRISE wtTrapReceiver2x2 VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Action 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Trap-Receiver Action 6" --#SUMMARY "Action 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 46 wtTrapReceiver2x2Alert7 TRAP-TYPE ENTERPRISE wtTrapReceiver2x2 VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Action 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Trap-Receiver Action 7" --#SUMMARY "Action 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 47 wtTrapReceiver2x2Alert8 TRAP-TYPE ENTERPRISE wtTrapReceiver2x2 VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Action 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Trap-Receiver Action 8" --#SUMMARY "Action 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 48 wtTrapReceiver2x2Alert9 TRAP-TYPE ENTERPRISE wtTrapReceiver2x2 VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Action 9 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Trap-Receiver Action 9" --#SUMMARY "Action 9: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 49 wtTrapReceiver2x2Alert10 TRAP-TYPE ENTERPRISE wtTrapReceiver2x2 VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Action 10 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Trap-Receiver Action 10" --#SUMMARY "Action 10: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 50 wtTrapReceiver2x2Alert11 TRAP-TYPE ENTERPRISE wtTrapReceiver2x2 VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Action 11 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Trap-Receiver Action 11" --#SUMMARY "Action 11: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 51 wtTrapReceiver2x2Alert12 TRAP-TYPE ENTERPRISE wtTrapReceiver2x2 VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText } DESCRIPTION "This SNMP trap is generated when Action 12 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Trap-Receiver Action 12" --#SUMMARY "Action 12: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 52 wtTrapReceiver2x2AlertDiag TRAP-TYPE ENTERPRISE wtTrapReceiver2x2 VARIABLES { wtTrapReceiver2x2DiagErrorIndex, wtTrapReceiver2x2DiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Trap-Receiver Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- END