WebGraph-Thermometer-US-MIB DEFINITIONS ::= BEGIN ---------------------------------------------------------------- -- Revison: 1.26 ---------------------------------------------------------------- -- 28.06.2006 New: Community String Trap -- ---------------------------------------------------------------- -- Revison: 1.25 ---------------------------------------------------------------- -- 22.05.2006 Table entry names changed -- ---------------------------------------------------------------- -- Revison: 1.24 ---------------------------------------------------------------- -- 26.07.2005 #57605, WebGraph Thermometer -- CRON timer function ---------------------------------------------------------------- -- Revison: 1.23 ---------------------------------------------------------------- -- 14.07.2005 #57605, WebGraph Thermometer -- FTP functions ---------------------------------------------------------------- -- Revison: 1.22 ---------------------------------------------------------------- -- 02.06.2005 #57605, WebGraph Thermometer -- Trap NMS annotations ---------------------------------------------------------------- -- Revison: 1.21 ---------------------------------------------------------------- -- 19.04.2005 #57605, WebGraph Themometer -- Mail Authentication ---------------------------------------------------------------- -- Revison: 1.20 ---------------------------------------------------------------- -- 05.11.2004 #57605, WebGraph -- New: Syslog -- ---------------------------------------------------------------- -- Revison: 1.19 ---------------------------------------------------------------- -- 27.09.2004 #57601/3/4, Webio Digital -- New: -- Entry AlarmHysteresis corrected ---------------------------------------------------------------- -- Revison: 1.18 ---------------------------------------------------------------- -- 21.07.2004 #57601/3/4, Webio Anx -- New: -- Diagnosis ---------------------------------------------------------------- -- Revison: 1.17 ---------------------------------------------------------------- -- 28.06.2004 #57630/1/2, Webio Digital -- Neu: Puls Mode ---------------------------------------------------------------- -- Revison: 1.16 ---------------------------------------------------------------- -- 16.04.2004 New: #57632, Webio Digital EA24x24 -- -- #57630/1, Webio Digital EA12x12 -- New: -- wtWebioAn1GraphInputCounterClear ---------------------------------------------------------------- -- Revison: 1.15 ---------------------------------------------------------------- -- 27.02.2004 #57630/1, Webio Digital EA12x12 -- New: -- Length changed to 32 Bit: -- wtWebioEA12x12InputValue -- wtWebioEA12x12OutputValue -- wtWebioEA12x12LoadControlView -- wtWebioEA12x12LCShutDownView -- wtWebioEA12x12SetOutput -- wtWebioEA12x12AlarmInputTrigger -- wtWebioEA12x12AlarmOutputTrigger -- wtWebioEA12x12PortOutputSafetyState ---------------------------------------------------------------- -- Revison: 1.14 ---------------------------------------------------------------- -- 16.02.2004 #57630/1, Webio Digital EA12x12 -- New: -- Text: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger -- -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New: -- Alarm Hysteresis -- Alarm Clear Traps and Mails ---------------------------------------------------------------- -- Revison: 1.13 ---------------------------------------------------------------- -- 05.02.2004 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New: -- Text: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger ---------------------------------------------------------------- -- Revison: 1.12 ---------------------------------------------------------------- -- 05.11.2003 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New features: -- Mail : Option CSV attachment -- Port : Offset calibration -- Alarm : TCP Client mode ---------------------------------------------------------------- -- Revison: 1.11 ---------------------------------------------------------------- -- 28.10.2003 #57630/1, Webio Digital EA12x12 -- New features: -- Alarm : TCP Client mode -- Inputs: Puls filter ---------------------------------------------------------------- -- Revison: 1.10 ---------------------------------------------------------------- -- 22.07.2003 #57630, Webio Digital EA12x12 -- New navigation tree, new binary modes -- ---------------------------------------------------------------- -- Revison: 1.09 ---------------------------------------------------------------- -- 24.03.2003 Trap Enterprise (Type 1, 2) corrected ---------------------------------------------------------------- -- Revison: 1.08 ---------------------------------------------------------------- -- 04.03.2003 reconciled the language versions DE/US ---------------------------------------------------------------- -- Revison: 1.07 ---------------------------------------------------------------- -- 25.02.2003 Correction: wtWebioEA12x12LoadControl ---------------------------------------------------------------- -- Revison: 1.06 ---------------------------------------------------------------- -- 24.02.2003 New: -- #57630, Webio EA12x12, LoadControl Group -- Correction: Trap variable names ---------------------------------------------------------------- -- Revison: 1.05 ---------------------------------------------------------------- -- 21.01.2003 New: -- #57630, Webio EA12x12 ---------------------------------------------------------------- -- Revison: 1.04 ---------------------------------------------------------------- -- 02.01.2003 New: -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer, 8 alarms ---------------------------------------------------------------- -- Revison: 1.03 ---------------------------------------------------------------- -- 21.11.2002 New: -- #57604, 2xWebThermometer, BOOTP, StartupSite -- #57603, 8xWebThermometer, BOOTP, StartupSite ---------------------------------------------------------------- -- Revison: 1.02 ---------------------------------------------------------------- -- 26.07.2002 New: -- #57604, 2xWebThermometer -- #57603, 8xWebThermometer -- IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, PhysAddress FROM RFC1213-MIB enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI; -- IpAddress ::= -- [APPLICATION 0] -- IMPLICIT OCTET STRING (SIZE (4)) -- Counter ::= -- [APPLICATION 1] -- IMPLICIT INTEGER (0..4294967295) -- Gauge ::= -- [APPLICATION 2] -- IMPLICIT INTEGER (0..4294967295) -- TimeTicks ::= -- [APPLICATION 3] -- IMPLICIT INTEGER (0..4294967295) -- DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING -- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } -- privat OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { privat 1 } -- Wiesemann & Theis Com-Server MIB wut OBJECT IDENTIFIER ::= { enterprises 5040 } wtComServer OBJECT IDENTIFIER ::= { wut 1 } wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 } -- wtWebio Tree wtWebioAn1Graph OBJECT IDENTIFIER ::= { wtWebio 8 } -- wtWebioAn1Graph Tree wtWebioAn1GraphTemp OBJECT IDENTIFIER ::= { wtWebioAn1Graph 1 } wtWebioAn1GraphSessCntrl OBJECT IDENTIFIER ::= { wtWebioAn1Graph 2 } wtWebioAn1GraphConfig OBJECT IDENTIFIER ::= { wtWebioAn1Graph 3 } -- wtWebioAn1GraphConfig Tree wtWebioAn1GraphDevice OBJECT IDENTIFIER ::= { wtWebioAn1GraphConfig 1 } wtWebioAn1GraphPorts OBJECT IDENTIFIER ::= { wtWebioAn1GraphConfig 2 } wtWebioAn1GraphManufact OBJECT IDENTIFIER ::= { wtWebioAn1GraphConfig 3 } wtWebioAn1GraphDiag OBJECT IDENTIFIER ::= { wtWebioAn1GraphConfig 4 } -- wtWebioAn1GraphDevice Tree wtWebioAn1GraphText OBJECT IDENTIFIER ::= { wtWebioAn1GraphDevice 1 } wtWebioAn1GraphTimeDate OBJECT IDENTIFIER ::= { wtWebioAn1GraphDevice 2 } wtWebioAn1GraphBasic OBJECT IDENTIFIER ::= { wtWebioAn1GraphDevice 3 } wtWebioAn1GraphDatalogger OBJECT IDENTIFIER ::= { wtWebioAn1GraphDevice 4 } wtWebioAn1GraphAlarm OBJECT IDENTIFIER ::= { wtWebioAn1GraphDevice 5 } -- wtWebioAn1GraphTimeDate Tree wtWebioAn1GraphTimeZone OBJECT IDENTIFIER ::= { wtWebioAn1GraphTimeDate 1 } wtWebioAn1GraphTimeServer OBJECT IDENTIFIER ::= { wtWebioAn1GraphTimeDate 2 } wtWebioAn1GraphDeviceClock OBJECT IDENTIFIER ::= { wtWebioAn1GraphTimeDate 3 } -- wtWebioAn1GraphBasic Tree wtWebioAn1GraphNetwork OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 1 } wtWebioAn1GraphHTML OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 2 } wtWebioAn1GraphMail OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 3 } wtWebioAn1GraphSNMP OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 4 } wtWebioAn1GraphUDP OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 5 } wtWebioAn1GraphSyslog OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 6 } wtWebioAn1GraphFTP OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 7 } wtWebioAn1GraphHTTP OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 8 } -- wtWebioAn1GraphTemp Group ------------------------ wtWebioAn1GraphSensors OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Number of temperature sensors" ::= { wtWebioAn1GraphTemp 1 } -- Interface Table wtWebioAn1GraphSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensors." ::= { wtWebioAn1GraphTemp 2 } wtWebioAn1GraphSensorEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Temperature sensor numbers." INDEX { wtWebioAn1GraphSensorNo } ::= { wtWebioAn1GraphSensorTable 1 } WtWebioAn1GraphSensorEntry ::= SEQUENCE { wtWebioAn1GraphSensorNo INTEGER } wtWebioAn1GraphSensorNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature sensor number." ::= { wtWebioAn1GraphSensorEntry 1 } -- wtWebioAn1GraphTempValue Table wtWebioAn1GraphTempValueTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of temperature values corresponding to the channel numbers." ::= { wtWebioAn1GraphTemp 3 } wtWebioAn1GraphTempValueEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Temperatures of the sensors." INDEX { wtWebioAn1GraphSensorNo } ::= { wtWebioAn1GraphTempValueTable 1 } WtWebioAn1GraphTempValueEntry ::= SEQUENCE{ wtWebioAn1GraphTempValue OCTET STRING } wtWebioAn1GraphTempValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature value of the sensor, ASCII, 5 characters in length." ::= { wtWebioAn1GraphTempValueEntry 1 } -- wtWebioAn1GraphBinaryTempValue Table wtWebioAn1GraphBinaryTempValueTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphBinaryTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of binary temperature values corresponding to the channel numbers." ::= { wtWebioAn1GraphTemp 4 } wtWebioAn1GraphBinaryTempValueEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphBinaryTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary temperature values of the sensors." INDEX { wtWebioAn1GraphSensorNo } ::= { wtWebioAn1GraphBinaryTempValueTable 1 } WtWebioAn1GraphBinaryTempValueEntry ::= SEQUENCE{ wtWebioAn1GraphBinaryTempValue INTEGER } wtWebioAn1GraphBinaryTempValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Binary temperature value of the sensor in 1/10 degrees Celsius, signed number, 0x7FFF indicates an invalid measured value." ::= { wtWebioAn1GraphBinaryTempValueEntry 1 } -- wtWebioAn1GraphSessCntrl Group -------------------------------- wtWebioAn1GraphSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebioAn1GraphSessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebioAn1GraphSessCntrl 1 } wtWebioAn1GraphSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphSessCntrl-NoSession(0), wtWebioAn1GraphSessCntrl-Session(1) } ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebioAn1GraphSessCntrl 2 } wtWebioAn1GraphSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebioAn1GraphSessCntrl 3 } wtWebioAn1GraphSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebioAn1GraphSessCntrl 4 } wtWebioAn1GraphSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebioAn1GraphSessCntrl 5 } -- wtWebioAn1GraphText Group ------------------------ wtWebioAn1GraphDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebioAn1GraphText 1 } wtWebioAn1GraphDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebioAn1GraphText 2 } wtWebioAn1GraphDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebioAn1GraphText 3 } wtWebioAn1GraphDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebioAn1GraphText 4 } -- wtWebioAn1GraphTimeZone Group ---------------------------- wtWebioAn1GraphTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebioAn1GraphTimeZone 1 } wtWebioAn1GraphTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebioAn1GraphTimeZone 2 } wtWebioAn1GraphTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebioAn1GraphTimeZone 3 } wtWebioAn1GraphStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebioAn1GraphTimeZone 4 } wtWebioAn1GraphStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebioAn1GraphTimeZone 5 } wtWebioAn1GraphStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebioAn1GraphTimeZone 6 } wtWebioAn1GraphStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphStartMonth-January(1), wtWebioAn1GraphStartMonth-February(2), wtWebioAn1GraphStartMonth-March(3), wtWebioAn1GraphStartMonth-April(4), wtWebioAn1GraphStartMonth-May(5), wtWebioAn1GraphStartMonth-June(6), wtWebioAn1GraphStartMonth-July(7), wtWebioAn1GraphStartMonth-August(8), wtWebioAn1GraphStartMonth-September(9), wtWebioAn1GraphStartMonth-October(10), wtWebioAn1GraphStartMonth-November(11), wtWebioAn1GraphStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebioAn1GraphTimeZone 7 } wtWebioAn1GraphStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphStartMode-first(1), wtWebioAn1GraphStartMode-second(2), wtWebioAn1GraphStartMode-third(3), wtWebioAn1GraphStartMode-fourth(4), wtWebioAn1GraphStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebioAn1GraphTimeZone 8 } wtWebioAn1GraphStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphStartWday-Sunday(1), wtWebioAn1GraphStartWday-Monday(2), wtWebioAn1GraphStartWday-Tuesday(3), wtWebioAn1GraphStartWday-Thursday(4), wtWebioAn1GraphStartWday-Wednesday(5), wtWebioAn1GraphStartWday-Friday(6), wtWebioAn1GraphStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebioAn1GraphTimeZone 9 } wtWebioAn1GraphStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioAn1GraphTimeZone 10 } wtWebioAn1GraphStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioAn1GraphTimeZone 11 } wtWebioAn1GraphStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphStopMonth-January(1), wtWebioAn1GraphStopMonth-February(2), wtWebioAn1GraphStopMonth-March(3), wtWebioAn1GraphStopMonth-April(4), wtWebioAn1GraphStopMonth-May(5), wtWebioAn1GraphStopMonth-June(6), wtWebioAn1GraphStopMonth-July(7), wtWebioAn1GraphStopMonth-August(8), wtWebioAn1GraphStopMonth-September(9), wtWebioAn1GraphStopMonth-October(10), wtWebioAn1GraphStopMonth-November(11), wtWebioAn1GraphStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebioAn1GraphTimeZone 12 } wtWebioAn1GraphStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphStopMode-first(1), wtWebioAn1GraphStopMode-second(2), wtWebioAn1GraphStopMode-third(3), wtWebioAn1GraphStopMode-fourth(4), wtWebioAn1GraphStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebioAn1GraphTimeZone 13 } wtWebioAn1GraphStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphStopWday-Sunday(1), wtWebioAn1GraphStopWday-Monday(2), wtWebioAn1GraphStopWday-Tuesday(3), wtWebioAn1GraphStopWday-Thursday(4), wtWebioAn1GraphStopWday-Wednesday(5), wtWebioAn1GraphStopWday-Friday(6), wtWebioAn1GraphStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebioAn1GraphTimeZone 14 } wtWebioAn1GraphStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioAn1GraphTimeZone 15 } wtWebioAn1GraphStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioAn1GraphTimeZone 16 } -- wtWebioAn1GraphTimeServer Group ---------------------------- wtWebioAn1GraphTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebioAn1GraphTimeServer 1 } wtWebioAn1GraphTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebioAn1GraphTimeServer 2 } wtWebioAn1GraphTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebioAn1GraphTimeServer 3 } wtWebioAn1GraphTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebioAn1GraphTimeServer 4 } -- wtWebioAn1GraphDeviceClock Group ---------------------------- wtWebioAn1GraphClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebioAn1GraphDeviceClock 1 } wtWebioAn1GraphClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebioAn1GraphDeviceClock 2 } wtWebioAn1GraphClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebioAn1GraphDeviceClock 3 } wtWebioAn1GraphClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphClockMonth-January(1), wtWebioAn1GraphClockMonth-February(2), wtWebioAn1GraphClockMonth-March(3), wtWebioAn1GraphClockMonth-April(4), wtWebioAn1GraphClockMonth-May(5), wtWebioAn1GraphClockMonth-June(6), wtWebioAn1GraphClockMonth-July(7), wtWebioAn1GraphClockMonth-August(8), wtWebioAn1GraphClockMonth-September(9), wtWebioAn1GraphClockMonth-October(10), wtWebioAn1GraphClockMonth-November(11), wtWebioAn1GraphClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebioAn1GraphDeviceClock 4 } wtWebioAn1GraphClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebioAn1GraphDeviceClock 5 } -- wtWebioAn1GraphNetwork Group ------------------------ wtWebioAn1GraphIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebioAn1GraphNetwork 1 } wtWebioAn1GraphSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebioAn1GraphNetwork 2 } wtWebioAn1GraphGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebioAn1GraphNetwork 3 } wtWebioAn1GraphDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebioAn1GraphNetwork 4 } wtWebioAn1GraphDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebioAn1GraphNetwork 5 } wtWebioAn1GraphAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: BOOTP disable " ::= { wtWebioAn1GraphNetwork 6 } -- wtWebioAn1GraphHTTP Group -------------------------------- wtWebioAn1GraphStartup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time." ::= { wtWebioAn1GraphHTTP 1 } wtWebioAn1GraphGetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If this bit is set, every answer of a short form GET question will be lead by the IP-address and name of the device: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : GET Header enable" ::= { wtWebioAn1GraphHTTP 2 } wtWebioAn1GraphHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebioAn1GraphHTTP 3 } -- wtWebioAn1GraphMail Group -------------------------------- wtWebioAn1GraphMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebioAn1GraphMail 1 } wtWebioAn1GraphMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebioAn1GraphMail 2 } wtWebioAn1GraphMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebioAn1GraphMail 3 } wtWebioAn1MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebioAn1GraphMail 4 } wtWebioAn1GraphMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebioAn1GraphMail 5 } wtWebioAn1GraphMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebioAn1GraphMail 6 } wtWebioAn1GraphMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebioAn1GraphMail 7 } wtWebioAn1GraphMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebioAn1GraphMail 8 } -- wtWebioAn1GraphSNMP Group -------------------------------- wtWebioAn1GraphSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebioAn1GraphSNMP 1 } wtWebioAn1GraphSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebioAn1GraphSNMP 2 } wtWebioAn1GraphSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebioAn1GraphSNMP 3 } wtWebioAn1GraphSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused" ::= { wtWebioAn1GraphSNMP 4 } wtWebioAn1GraphSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebioAn1GraphSNMP 5 } wtWebioAn1GraphSnmpCommunityStringTrap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string of the traps." ::= { wtWebioAn1GraphSNMP 6 } -- wtWebioAn1GraphUDP Group -------------------------------- wtWebioAn1GraphUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebioAn1GraphUDP 1 } wtWebioAn1GraphUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebioAn1GraphUDP 2 } -- wtWebioAn1GraphSyslog Group -------------------------------- wtWebioAn1GraphSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebioAn1GraphSyslog 1 } wtWebioAn1GraphSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebioAn1GraphSyslog 2 } wtWebioAn1GraphSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebioAn1GraphSyslog 3 } wtWebioAn1GraphSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebioAn1GraphSyslog 4 } -- wtWebioAn1GraphFTP Group -------------------------------- wtWebioAn1GraphFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebioAn1GraphFTP 1 } wtWebioAn1GraphFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioAn1GraphFTP 2 } wtWebioAn1GraphFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebioAn1GraphFTP 3 } wtWebioAn1GraphFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebioAn1GraphFTP 4 } wtWebioAn1GraphFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebioAn1GraphFTP 5 } wtWebioAn1GraphFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebioAn1GraphFTP 6 } wtWebioAn1GraphFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebioAn1GraphFTP 7 } -- wtWebioAn1GraphDatalogger Group -------------------------------- wtWebioAn1GraphLoggerTimebase OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphDatalogger-1Min(1), wtWebioAn1GraphDatalogger-5Min(2), wtWebioAn1GraphDatalogger-15Min(3), wtWebioAn1GraphDatalogger-60Min(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Time base of the data logger" ::= { wtWebioAn1GraphDatalogger 1 } wtWebioAn1GraphLoggerSensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn1GraphDatalogger 2 } wtWebioAn1GraphDisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn1GraphDatalogger 3 } -- Graph Sensor Color Table wtWebioAn1GraphSensorColorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor colors for the praphical presentation." ::= { wtWebioAn1GraphDatalogger 4 } wtWebioAn1GraphSensorColorEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Index numbers of the sensors." INDEX { wtWebioAn1GraphSensorNo } ::= { wtWebioAn1GraphSensorColorTable 1 } WtWebioAn1GraphSensorColorEntry ::= SEQUENCE { wtWebioAn1GraphSensorColor OCTET STRING } wtWebioAn1GraphSensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Color of the sensors at the praphical presention." ::= { wtWebioAn1GraphSensorColorEntry 1 } wtWebioAn1GraphAutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable" ::= { wtWebioAn1GraphDatalogger 5 } wtWebioAn1GraphVerticalUpperLimit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn1GraphDatalogger 6 } wtWebioAn1GraphVerticalLowerLimit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn1GraphDatalogger 7 } wtWebioAn1GraphHorizontalZoom OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphZoom-25min(1), wtWebioAn1GraphZoom-75min(2), wtWebioAn1GraphZoom-5hrs(3), wtWebioAn1GraphZoom-30hrs(4), wtWebioAn1GraphZoom-5days(5), wtWebioAn1GraphZoom-25days(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines the default zoom stage, if no auto scaling is selected." ::= { wtWebioAn1GraphDatalogger 8 } -- wtWebioAn1GraphAlarm Group ---------------------------- wtWebioAn1GraphAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebioAn1GraphAlarm 1 } -- Alarm Interface Table wtWebioAn1GraphAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebioAn1GraphAlarm 2 } wtWebioAn1GraphAlarmIfEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebioAn1GraphAlarmNo } ::= { wtWebioAn1GraphAlarmIfTable 1 } WtWebioAn1GraphAlarmIfEntry ::= SEQUENCE { wtWebioAn1GraphAlarmNo INTEGER } wtWebioAn1GraphAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm number." ::= { wtWebioAn1GraphAlarmIfEntry 1 } -- Alarm Table wtWebioAn1GraphAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebioAn1GraphAlarm 3 } wtWebioAn1GraphAlarmEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebioAn1GraphAlarmNo } ::= { wtWebioAn1GraphAlarmTable 1 } WtWebioAn1GraphAlarmEntry ::= SEQUENCE { wtWebioAn1GraphAlarmTrigger OCTET STRING, wtWebioAn1GraphAlarmMin OCTET STRING, wtWebioAn1GraphAlarmMax OCTET STRING, wtWebioAn1GraphAlarmHysteresis OCTET STRING, wtWebioAn1GraphAlarmDelay OCTET STRING, wtWebioAn1GraphAlarmInterval OCTET STRING, wtWebioAn1GraphAlarmEnable OCTET STRING, wtWebioAn1GraphAlarmEMailAddr OCTET STRING, wtWebioAn1GraphAlarmMailSubject OCTET STRING, wtWebioAn1GraphAlarmMailText OCTET STRING, wtWebioAn1GraphAlarmManagerIP OCTET STRING, wtWebioAn1GraphAlarmTrapText OCTET STRING, wtWebioAn1GraphAlarmMailOptions OCTET STRING, wtWebioAn1GraphAlarmTcpIpAddr OCTET STRING, wtWebioAn1GraphAlarmTcpPort INTEGER, wtWebioAn1GraphAlarmTcpText OCTET STRING, wtWebioAn1GraphAlarmClearMailSubject OCTET STRING, wtWebioAn1GraphAlarmClearMailText OCTET STRING, wtWebioAn1GraphAlarmClearTrapText OCTET STRING, wtWebioAn1GraphAlarmClearTcpText OCTET STRING, wtWebioAn1GraphAlarmSyslogIpAddr OCTET STRING, wtWebioAn1GraphAlarmSyslogPort INTEGER, wtWebioAn1GraphAlarmSyslogText OCTET STRING, wtWebioAn1GraphAlarmFtpDataPort OCTET STRING, wtWebioAn1GraphAlarmFtpFileName OCTET STRING, wtWebioAn1GraphAlarmFtpText OCTET STRING, wtWebioAn1GraphAlarmFtpClearText OCTET STRING, wtWebioAn1GraphAlarmFtpOption OCTET STRING, wtWebioAn1GraphAlarmTimerCron OCTET STRING } wtWebioAn1GraphAlarmTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn1GraphAlarmEntry 1 } wtWebioAn1GraphAlarmMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn1GraphAlarmEntry 2 } wtWebioAn1GraphAlarmMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn1GraphAlarmEntry 3 } wtWebioAn1GraphAlarmHysteresis OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places." ::= { wtWebioAn1GraphAlarmEntry 4 } wtWebioAn1GraphAlarmDelay OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes)." ::= { wtWebioAn1GraphAlarmEntry 5 } wtWebioAn1GraphAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebioAn1GraphAlarmEntry 6 } wtWebioAn1GraphAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable" ::= { wtWebioAn1GraphAlarmEntry 7 } wtWebioAn1GraphAlarmEMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebioAn1GraphAlarmEntry 8 } wtWebioAn1GraphAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioAn1GraphAlarmEntry 9 } wtWebioAn1GraphAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: provides the current temperature; n = 1..8. provides the current time." ::= { wtWebioAn1GraphAlarmEntry 10 } wtWebioAn1GraphAlarmManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the SNMP Manager which accepts the trap." ::= { wtWebioAn1GraphAlarmEntry 11 } wtWebioAn1GraphAlarmTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebioAn1GraphAlarmEntry 12 } wtWebioAn1GraphAlarmMailOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1-7: unused" ::= { wtWebioAn1GraphAlarmEntry 13 } wtWebioAn1GraphAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the trap." ::= { wtWebioAn1GraphAlarmEntry 14 } wtWebioAn1GraphAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the trap." ::= { wtWebioAn1GraphAlarmEntry 15 } wtWebioAn1GraphAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebioAn1GraphAlarmEntry 16 } wtWebioAn1GraphAlarmClearMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm clear mail." ::= { wtWebioAn1GraphAlarmEntry 17 } wtWebioAn1GraphAlarmClearMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Alarm clear mail text: provides the current temperature; n = 1..8. provides the current time." ::= { wtWebioAn1GraphAlarmEntry 18 } wtWebioAn1GraphAlarmClearTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebioAn1GraphAlarmEntry 19 } wtWebioAn1GraphAlarmClearTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebioAn1GraphAlarmEntry 20 } wtWebioAn1GraphAlarmSyslogIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioAn1GraphAlarmEntry 21 } wtWebioAn1GraphAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioAn1GraphAlarmEntry 22 } wtWebioAn1GraphAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioAn1GraphAlarmEntry 23 } wtWebioAn1GraphAlarmSyslogClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioAn1GraphAlarmEntry 24 } wtWebioAn1GraphAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebioAn1GraphAlarmEntry 25 } wtWebioAn1GraphAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebioAn1GraphAlarmEntry 26 } wtWebioAn1GraphAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioAn1GraphAlarmEntry 27 } wtWebioAn1GraphAlarmFtpClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm clear message to store on the FTP server." ::= { wtWebioAn1GraphAlarmEntry 28 } wtWebioAn1GraphAlarmFtpOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebioAn1GraphAlarmEntry 29 } wtWebioAn1GraphAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 text fields space or tab seperated for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separately. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebioAn1GraphAlarmEntry 30 } -- wtWebioAn1GraphPorts Group ---------------------------- -- Table wtWebioAn1GraphPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the sensor number." ::= { wtWebioAn1GraphPorts 1 } wtWebioAn1GraphPortEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sensor parameters for the individual sensors." INDEX { wtWebioAn1GraphSensorNo } ::= { wtWebioAn1GraphPortTable 1 } WtWebioAn1GraphPortEntry ::= SEQUENCE { wtWebioAn1GraphPortName OCTET STRING, wtWebioAn1GraphPortText OCTET STRING, wtWebioAn1GraphPortOffset1 OCTET STRING, wtWebioAn1GraphPortTemperature1 OCTET STRING, wtWebioAn1GraphPortOffset2 OCTET STRING, wtWebioAn1GraphPortTemperature2 OCTET STRING, wtWebioAn1GraphPortComment OCTET STRING } wtWebioAn1GraphPortName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the sensor." ::= { wtWebioAn1GraphPortEntry 1 } wtWebioAn1GraphPortText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the sensor." ::= { wtWebioAn1GraphPortEntry 2 } wtWebioAn1GraphPortOffset1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1." ::= { wtWebioAn1GraphPortEntry 3 } wtWebioAn1GraphPortTemperature1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places." ::= { wtWebioAn1GraphPortEntry 4 } wtWebioAn1GraphPortOffset2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2." ::= { wtWebioAn1GraphPortEntry 5 } wtWebioAn1GraphPortTemperature2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places." ::= { wtWebioAn1GraphPortEntry 6 } wtWebioAn1GraphPortComment OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: informations of date, name of operator, reference devices." ::= { wtWebioAn1GraphPortEntry 7 } -- wtWebioAn1GraphManufact Group ---------------------------- wtWebioAn1GraphMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebioAn1GraphManufact 1 } wtWebioAn1GraphMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebioAn1GraphManufact 2 } wtWebioAn1GraphMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebioAn1GraphManufact 3 } wtWebioAn1GraphMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebioAn1GraphManufact 4 } wtWebioAn1GraphMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebioAn1GraphManufact 5 } wtWebioAn1GraphMfOrderNo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer part number." ::= { wtWebioAn1GraphManufact 6 } -- wtWebioAn1GraphDiag Group ---------------------------- wtWebioAn1GraphDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebioAn1GraphDiag 1 } wtWebioAn1GraphDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebioAn1GraphDiag 2 } wtWebioAn1GraphDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebioAn1GraphDiagErrorMessage. Errors are numbered from 1 to wtWebioAn1GraphDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioAn1GraphDiagErrorMessage." ::= { wtWebioAn1GraphDiag 3 } wtWebioAn1GraphDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebioAn1GraphDiagErrorIndex as an index, the appropriate message is available." ::= { wtWebioAn1GraphDiag 4 } wtWebioAn1GraphDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebioAn1GraphDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebioAn1GraphAlert1 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 31 wtWebioAn1GraphAlert2 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 32 wtWebioAn1GraphAlert3 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 33 wtWebioAn1GraphAlert4 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 34 wtWebioAn1GraphAlert5 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 35 wtWebioAn1GraphAlert6 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 36 wtWebioAn1GraphAlert7 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 37 wtWebioAn1GraphAlert8 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 38 wtWebioAn1GraphAlert9 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 91 wtWebioAn1GraphAlert10 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 92 wtWebioAn1GraphAlert11 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 93 wtWebioAn1GraphAlert12 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 94 wtWebioAn1GraphAlert13 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 95 wtWebioAn1GraphAlert14 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 96 wtWebioAn1GraphAlert15 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 97 wtWebioAn1GraphAlert16 TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 98 wtWebioAn1GraphAlertDiag TRAP-TYPE ENTERPRISE wtWebioAn1Graph VARIABLES { wtWebioAn1GraphDiagErrorIndex, wtWebioAn1GraphDiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 END