WebGraph-AnalogIO-57762-US-MIB DEFINITIONS ::= BEGIN ---------------------------------------------------------------- -- Revison: 1.31 ---------------------------------------------------------------- -- 27.03.2018 New: Mail Auth, SNMP destination port -- Binary HttpPort, time base report -- MQTT, REST ---------------------------------------------------------------- -- Revison: 1.30 ---------------------------------------------------------------- -- 08.01.2010 New: Reports -- ---------------------------------------------------------------- -- Revison: 1.29 ---------------------------------------------------------------- -- 01.10.2009 Webio -- New Analog Out: 57762 ---------------------------------------------------------------- -- Revison: 1.28 ---------------------------------------------------------------- -- 02.12.2008 Webio -- New Graphics java script base parameter ---------------------------------------------------------------- -- Revison: 1.27 ---------------------------------------------------------------- -- 09.11.2006 Webio -- DHCP enable ---------------------------------------------------------------- -- Revison: 1.26 ---------------------------------------------------------------- -- 28.06.2006 New: Community String Trap -- ---------------------------------------------------------------- -- Revison: 1.25 ---------------------------------------------------------------- -- 25.11.2005 #57641, WebGraph AnalogIn -- OID correction ---------------------------------------------------------------- -- Revison: 1.24 ---------------------------------------------------------------- -- 26.07.2005 #57641, WebGraph AnalogIn -- CRON timer function ---------------------------------------------------------------- -- Revison: 1.23 ---------------------------------------------------------------- -- 14.07.2005 #57641, WebGraph AnalogIn -- FTP functions ---------------------------------------------------------------- -- Revison: 1.22 ---------------------------------------------------------------- -- 17.05.2005 #57641, WebGraph AnalogIn -- Trap NMS annotations ---------------------------------------------------------------- -- Revison: 1.21 ---------------------------------------------------------------- -- 19.04.2005 #57605, WebGraph Themometer -- Mail Authentication ---------------------------------------------------------------- -- Revison: 1.20 ---------------------------------------------------------------- -- 05.11.2004 #57606, WebGraph Thermo-Hygrometer -- New: Syslog -- ---------------------------------------------------------------- -- Revison: 1.19 ---------------------------------------------------------------- -- 08.09.2004 #57606 WebGraph Thermo-Hygrometer -- New: -- wtWebGraphThermHygroAlarmRHMin -- wtWebGraphThermHygroAlarmRHMax -- wtWebGraphThermHygroAlarmRHHysteresis -- wtWebGraphThermHygroPortSensorSelect -- wtWebGraphThermHygroAlarmDeltaTemp -- wtWebGraphThermHygroAlarmAHMin -- wtWebGraphThermHygroAlarmAHMax ---------------------------------------------------------------- -- Revison: 1.18 ---------------------------------------------------------------- -- 21.07.2004 #57601/3/4, Webio Anx -- New: -- Diagnosis ---------------------------------------------------------------- -- Revison: 1.17 ---------------------------------------------------------------- -- 28.06.2004 #57630/1/2, Webio Digital -- Neu: Puls Mode ---------------------------------------------------------------- -- Revison: 1.16 ---------------------------------------------------------------- -- 16.04.2004 New: #57632, Webio Digital EA24x24 -- -- #57630/1, Webio Digital EA12x12 -- New: -- wtWebioEA12x12InputCounterClear ---------------------------------------------------------------- -- Revison: 1.15 ---------------------------------------------------------------- -- 27.02.2004 #57630/1, Webio Digital EA12x12 -- New: -- Length changed to 32 Bit: -- wtWebioEA12x12InputValue -- wtWebioEA12x12OutputValue -- wtWebioEA12x12LoadControlView -- wtWebioEA12x12LCShutDownView -- wtWebioEA12x12SetOutput -- wtWebioEA12x12AlarmInputTrigger -- wtWebioEA12x12AlarmOutputTrigger -- wtWebioEA12x12PortOutputSafetyState ---------------------------------------------------------------- -- Revison: 1.14 ---------------------------------------------------------------- -- 16.02.2004 #57630/1, Webio Digital EA12x12 -- New: -- Text: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger -- -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New: -- Alarm Hysteresis -- Alarm Clear Traps and Mails ---------------------------------------------------------------- -- Revison: 1.13 ---------------------------------------------------------------- -- 05.02.2004 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New: -- Text: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger ---------------------------------------------------------------- -- Revison: 1.12 ---------------------------------------------------------------- -- 05.11.2003 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New features: -- Mail : Option CSV attachment -- Port : Offset calibration -- Alarm : TCP Client mode ---------------------------------------------------------------- -- Revison: 1.11 ---------------------------------------------------------------- -- 28.10.2003 #57630/1, Webio Digital EA12x12 -- New features: -- Alarm : TCP Client mode -- Inputs: Puls filter ---------------------------------------------------------------- -- Revison: 1.10 ---------------------------------------------------------------- -- 22.07.2003 #57630, Webio Digital EA12x12 -- New navigation tree, new binary modes -- ---------------------------------------------------------------- -- Revison: 1.09 ---------------------------------------------------------------- -- 24.03.2003 Trap Enterprise (Type 1, 2) corrected ---------------------------------------------------------------- -- Revison: 1.08 ---------------------------------------------------------------- -- 04.03.2003 reconciled the language versions DE/US ---------------------------------------------------------------- -- Revison: 1.07 ---------------------------------------------------------------- -- 25.02.2003 Correction: wtWebioEA12x12LoadControl ---------------------------------------------------------------- -- Revison: 1.06 ---------------------------------------------------------------- -- 24.02.2003 New: -- #57630, Webio EA12x12, LoadControl Group -- Correction: Trap variable names ---------------------------------------------------------------- -- Revison: 1.05 ---------------------------------------------------------------- -- 21.01.2003 New: -- #57630, Webio EA12x12 ---------------------------------------------------------------- -- Revison: 1.04 ---------------------------------------------------------------- -- 02.01.2003 New: -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer, 8 alarms ---------------------------------------------------------------- -- Revison: 1.03 ---------------------------------------------------------------- -- 21.11.2002 New: -- #57604, 2xWebThermometer, BOOTP, StartupSite -- #57603, 8xWebThermometer, BOOTP, StartupSite ---------------------------------------------------------------- -- Revison: 1.02 ---------------------------------------------------------------- -- 26.07.2002 New: -- #57604, 2xWebThermometer -- #57603, 8xWebThermometer -- IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, PhysAddress FROM RFC1213-MIB enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI; -- IpAddress ::= -- [APPLICATION 0] -- IMPLICIT OCTET STRING (SIZE (4)) -- Counter ::= -- [APPLICATION 1] -- IMPLICIT INTEGER (0..4294967295) -- Gauge ::= -- [APPLICATION 2] -- IMPLICIT INTEGER (0..4294967295) -- TimeTicks ::= -- [APPLICATION 3] -- IMPLICIT INTEGER (0..4294967295) -- DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING -- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } -- privat OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { privat 1 } -- Wiesemann & Theis Com-Server MIB wut OBJECT IDENTIFIER ::= { enterprises 5040 } wtComServer OBJECT IDENTIFIER ::= { wut 1 } wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 } -- wtWebGraph Tree wtWebGraphAnalog57762 OBJECT IDENTIFIER ::= { wtWebio 29 } -- wtWebGraphAnalog57762 Tree wtWebGraphAnalog57762Inventory OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762 1 } wtWebGraphAnalog57762SessCntrl OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762 2 } wtWebGraphAnalog57762Config OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762 3 } wtWebGraphAnalog57762Diag OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762 4 } -- wtWebGraphAnalog57762Config Tree wtWebGraphAnalog57762Device OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Config 1 } wtWebGraphAnalog57762Ports OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Config 2 } wtWebGraphAnalog57762Manufact OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Config 3 } -- wtWebGraphAnalog57762Device Tree wtWebGraphAnalog57762Text OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 1 } wtWebGraphAnalog57762TimeDate OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 2 } wtWebGraphAnalog57762Basic OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 3 } wtWebGraphAnalog57762Datalogger OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 4 } wtWebGraphAnalog57762Alarm OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 5 } wtWebGraphAnalog57762Graphics OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 6 } -- wtWebGraphAnalog57762TimeDate Tree wtWebGraphAnalog57762TimeZone OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762TimeDate 1 } wtWebGraphAnalog57762TimeServer OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762TimeDate 2 } wtWebGraphAnalog57762DeviceClock OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762TimeDate 3 } -- wtWebGraphAnalog57762Basic Tree wtWebGraphAnalog57762Network OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 1 } wtWebGraphAnalog57762HTTP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 2 } wtWebGraphAnalog57762Mail OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 3 } wtWebGraphAnalog57762SNMP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 4 } wtWebGraphAnalog57762UDP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 5 } wtWebGraphAnalog57762Syslog OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 6 } wtWebGraphAnalog57762FTP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 7 } wtWebGraphAnalog57762Language OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 8 } wtWebGraphAnalog57762Binary OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 9 } wtWebGraphAnalog57762MQTT OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 12 } wtWebGraphAnalog57762REST OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 13 } -- wtWebGraphAnalog57762Graphics Tree wtWebGraphAnalog57762GraphicsBase OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Graphics 1 } wtWebGraphAnalog57762GraphicsSelect OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Graphics 2 } wtWebGraphAnalog57762GraphicsScale OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Graphics 3 } -- wtWebGraphAnalog57762Inventory Group ------------------------ wtWebGraphAnalog57762Sensors OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of sensors" ::= { wtWebGraphAnalog57762Inventory 1 } -- Interface Table wtWebGraphAnalog57762SensorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57762SensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensors." ::= { wtWebGraphAnalog57762Inventory 2 } wtWebGraphAnalog57762SensorEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57762SensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor numbers." INDEX { wtWebGraphAnalog57762SensorNo } ::= { wtWebGraphAnalog57762SensorTable 1 } WtWebGraphAnalog57762SensorEntry ::= SEQUENCE { wtWebGraphAnalog57762SensorNo INTEGER } wtWebGraphAnalog57762SensorNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor number." ::= { wtWebGraphAnalog57762SensorEntry 1 } -- wtWebGraphAnalog57762Values Table wtWebGraphAnalog57762ValuesTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57762ValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of measurement values corresponding to the channel numbers." ::= { wtWebGraphAnalog57762Inventory 3 } wtWebGraphAnalog57762ValuesEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57762ValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Measurement values of the sensors." INDEX { wtWebGraphAnalog57762SensorNo } ::= { wtWebGraphAnalog57762ValuesTable 1 } WtWebGraphAnalog57762ValuesEntry ::= SEQUENCE{ wtWebGraphAnalog57762Values OCTET STRING } wtWebGraphAnalog57762Values OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-write STATUS mandatory DESCRIPTION "Measurement value of the sensor, ASCII. This value will be translated according to the ports settings for the read and write operations." ::= { wtWebGraphAnalog57762ValuesEntry 1 } -- wtWebGraphAnalog57762BinaryValues Table wtWebGraphAnalog57762BinaryValuesTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57762BinaryValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of binary measurement values corresponding to the channel numbers." ::= { wtWebGraphAnalog57762Inventory 4 } wtWebGraphAnalog57762BinaryValuesEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57762BinaryValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary measurement values of the sensors." INDEX { wtWebGraphAnalog57762SensorNo } ::= { wtWebGraphAnalog57762BinaryValuesTable 1 } WtWebGraphAnalog57762BinaryValuesEntry ::= SEQUENCE{ wtWebGraphAnalog57762BinaryValues INTEGER } wtWebGraphAnalog57762BinaryValues OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Binary measurement value of the sensor in 1/1000, signed number, 0x7FFFFFFF indicates an invalid value. This value will be translated according to the ports settings for the read and write operations." ::= { wtWebGraphAnalog57762BinaryValuesEntry 1 } -- wtWebGraphAnalog57762ValuesPoint Table wtWebGraphAnalog57762ValuesPointTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57762ValuesPointEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of measurement values corresponding to the channel numbers." ::= { wtWebGraphAnalog57762Inventory 8 } wtWebGraphAnalog57762ValuesPointEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57762ValuesPointEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Measurement values of the sensors." INDEX { wtWebGraphAnalog57762SensorNo } ::= { wtWebGraphAnalog57762ValuesPointTable 1 } WtWebGraphAnalog57762ValuesPointEntry ::= SEQUENCE{ wtWebGraphAnalog57762ValuesPoint OCTET STRING } wtWebGraphAnalog57762ValuesPoint OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-write STATUS mandatory DESCRIPTION "Measurement value of the sensor, ASCII. This value will be translated according to the ports settings for the read and write operations." ::= { wtWebGraphAnalog57762ValuesPointEntry 1 } -- wtWebGraphAnalog57762SessCntrl Group -------------------------------- wtWebGraphAnalog57762SessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebGraphAnalog57762SessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebGraphAnalog57762SessCntrl 1 } wtWebGraphAnalog57762SessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57762SessCntrl-NoSession(0), wtWebGraphAnalog57762SessCntrl-Session(1) } ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebGraphAnalog57762SessCntrl 2 } wtWebGraphAnalog57762SessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebGraphAnalog57762SessCntrl 3 } wtWebGraphAnalog57762SessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebGraphAnalog57762SessCntrl 4 } wtWebGraphAnalog57762SessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebGraphAnalog57762SessCntrl 5 } -- wtWebGraphAnalog57762Text Group ------------------------ wtWebGraphAnalog57762DeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebGraphAnalog57762Text 1 } wtWebGraphAnalog57762DeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebGraphAnalog57762Text 2 } wtWebGraphAnalog57762DeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebGraphAnalog57762Text 3 } wtWebGraphAnalog57762DeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebGraphAnalog57762Text 4 } -- wtWebGraphAnalog57762TimeZone Group ---------------------------- wtWebGraphAnalog57762TzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebGraphAnalog57762TimeZone 1 } wtWebGraphAnalog57762TzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebGraphAnalog57762TimeZone 2 } wtWebGraphAnalog57762TzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebGraphAnalog57762TimeZone 3 } wtWebGraphAnalog57762StTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebGraphAnalog57762TimeZone 4 } wtWebGraphAnalog57762StTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebGraphAnalog57762TimeZone 5 } wtWebGraphAnalog57762StTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebGraphAnalog57762TimeZone 6 } wtWebGraphAnalog57762StTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57762StartMonth-January(1), wtWebGraphAnalog57762StartMonth-February(2), wtWebGraphAnalog57762StartMonth-March(3), wtWebGraphAnalog57762StartMonth-April(4), wtWebGraphAnalog57762StartMonth-May(5), wtWebGraphAnalog57762StartMonth-June(6), wtWebGraphAnalog57762StartMonth-July(7), wtWebGraphAnalog57762StartMonth-August(8), wtWebGraphAnalog57762StartMonth-September(9), wtWebGraphAnalog57762StartMonth-October(10), wtWebGraphAnalog57762StartMonth-November(11), wtWebGraphAnalog57762StartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebGraphAnalog57762TimeZone 7 } wtWebGraphAnalog57762StTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57762StartMode-first(1), wtWebGraphAnalog57762StartMode-second(2), wtWebGraphAnalog57762StartMode-third(3), wtWebGraphAnalog57762StartMode-fourth(4), wtWebGraphAnalog57762StartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebGraphAnalog57762TimeZone 8 } wtWebGraphAnalog57762StTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57762StartWday-Sunday(1), wtWebGraphAnalog57762StartWday-Monday(2), wtWebGraphAnalog57762StartWday-Tuesday(3), wtWebGraphAnalog57762StartWday-Thursday(4), wtWebGraphAnalog57762StartWday-Wednesday(5), wtWebGraphAnalog57762StartWday-Friday(6), wtWebGraphAnalog57762StartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebGraphAnalog57762TimeZone 9 } wtWebGraphAnalog57762StTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebGraphAnalog57762TimeZone 10 } wtWebGraphAnalog57762StTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebGraphAnalog57762TimeZone 11 } wtWebGraphAnalog57762StTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57762StopMonth-January(1), wtWebGraphAnalog57762StopMonth-February(2), wtWebGraphAnalog57762StopMonth-March(3), wtWebGraphAnalog57762StopMonth-April(4), wtWebGraphAnalog57762StopMonth-May(5), wtWebGraphAnalog57762StopMonth-June(6), wtWebGraphAnalog57762StopMonth-July(7), wtWebGraphAnalog57762StopMonth-August(8), wtWebGraphAnalog57762StopMonth-September(9), wtWebGraphAnalog57762StopMonth-October(10), wtWebGraphAnalog57762StopMonth-November(11), wtWebGraphAnalog57762StopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebGraphAnalog57762TimeZone 12 } wtWebGraphAnalog57762StTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57762StopMode-first(1), wtWebGraphAnalog57762StopMode-second(2), wtWebGraphAnalog57762StopMode-third(3), wtWebGraphAnalog57762StopMode-fourth(4), wtWebGraphAnalog57762StopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebGraphAnalog57762TimeZone 13 } wtWebGraphAnalog57762StTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57762StopWday-Sunday(1), wtWebGraphAnalog57762StopWday-Monday(2), wtWebGraphAnalog57762StopWday-Tuesday(3), wtWebGraphAnalog57762StopWday-Thursday(4), wtWebGraphAnalog57762StopWday-Wednesday(5), wtWebGraphAnalog57762StopWday-Friday(6), wtWebGraphAnalog57762StopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebGraphAnalog57762TimeZone 14 } wtWebGraphAnalog57762StTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebGraphAnalog57762TimeZone 15 } wtWebGraphAnalog57762StTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebGraphAnalog57762TimeZone 16 } -- wtWebGraphAnalog57762TimeServer Group ---------------------------- wtWebGraphAnalog57762TimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebGraphAnalog57762TimeServer 1 } wtWebGraphAnalog57762TimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebGraphAnalog57762TimeServer 2 } wtWebGraphAnalog57762TsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebGraphAnalog57762TimeServer 3 } wtWebGraphAnalog57762TsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebGraphAnalog57762TimeServer 4 } -- wtWebGraphAnalog57762DeviceClock Group ---------------------------- wtWebGraphAnalog57762ClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebGraphAnalog57762DeviceClock 1 } wtWebGraphAnalog57762ClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebGraphAnalog57762DeviceClock 2 } wtWebGraphAnalog57762ClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebGraphAnalog57762DeviceClock 3 } wtWebGraphAnalog57762ClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57762ClockMonth-January(1), wtWebGraphAnalog57762ClockMonth-February(2), wtWebGraphAnalog57762ClockMonth-March(3), wtWebGraphAnalog57762ClockMonth-April(4), wtWebGraphAnalog57762ClockMonth-May(5), wtWebGraphAnalog57762ClockMonth-June(6), wtWebGraphAnalog57762ClockMonth-July(7), wtWebGraphAnalog57762ClockMonth-August(8), wtWebGraphAnalog57762ClockMonth-September(9), wtWebGraphAnalog57762ClockMonth-October(10), wtWebGraphAnalog57762ClockMonth-November(11), wtWebGraphAnalog57762ClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebGraphAnalog57762DeviceClock 4 } wtWebGraphAnalog57762ClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebGraphAnalog57762DeviceClock 5 } -- wtWebGraphAnalog57762Network Group ------------------------ wtWebGraphAnalog57762IpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebGraphAnalog57762Network 1 } wtWebGraphAnalog57762SubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebGraphAnalog57762Network 2 } wtWebGraphAnalog57762Gateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebGraphAnalog57762Network 3 } wtWebGraphAnalog57762DnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebGraphAnalog57762Network 4 } wtWebGraphAnalog57762DnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebGraphAnalog57762Network 5 } wtWebGraphAnalog57762AddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP disable Bit 0: BOOTP disable " ::= { wtWebGraphAnalog57762Network 6 } -- wtWebGraphAnalog57762HTTP Group -------------------------------- wtWebGraphAnalog57762Startup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time." ::= { wtWebGraphAnalog57762HTTP 1 } wtWebGraphAnalog57762GetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-6: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebGraphAnalog57762HTTP 2 } wtWebGraphAnalog57762HttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebGraphAnalog57762HTTP 3 } -- wtWebGraphAnalog57762Mail Group -------------------------------- wtWebGraphAnalog57762MailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebGraphAnalog57762Mail 1 } wtWebGraphAnalog57762MailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebGraphAnalog57762Mail 2 } wtWebGraphAnalog57762MailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebGraphAnalog57762Mail 3 } wtWebioAn1MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebGraphAnalog57762Mail 4 } wtWebGraphAnalog57762MailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebGraphAnalog57762Mail 5 } wtWebGraphAnalog57762MailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebGraphAnalog57762Mail 6 } wtWebGraphAnalog57762MailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebGraphAnalog57762Mail 7 } wtWebGraphAnalog57762MailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebGraphAnalog57762Mail 8 } -- wtWebGraphAnalog57762SNMP Group -------------------------------- wtWebGraphAnalog57762SnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebGraphAnalog57762SNMP 1 } wtWebGraphAnalog57762SnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebGraphAnalog57762SNMP 2 } wtWebGraphAnalog57762SystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebGraphAnalog57762SNMP 3 } wtWebGraphAnalog57762SystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused" ::= { wtWebGraphAnalog57762SNMP 4 } wtWebGraphAnalog57762SnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebGraphAnalog57762SNMP 5 } wtWebGraphAnalog57762SnmpCommunityStringTrap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string send within traps." ::= { wtWebGraphAnalog57762SNMP 6 } wtWebGraphAnalog57762SnmpSystemTrapManagerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the system trap." ::= { wtWebGraphAnalog57762SNMP 7 } -- wtWebGraphAnalog57762UDP Group -------------------------------- wtWebGraphAnalog57762UdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebGraphAnalog57762UDP 1 } wtWebGraphAnalog57762UdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebGraphAnalog57762UDP 2 } -- wtWebGraphAnalog57762Syslog Group -------------------------------- wtWebGraphAnalog57762SyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebGraphAnalog57762Syslog 1 } wtWebGraphAnalog57762SyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebGraphAnalog57762Syslog 2 } wtWebGraphAnalog57762SyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebGraphAnalog57762Syslog 3 } wtWebGraphAnalog57762SyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebGraphAnalog57762Syslog 4 } -- wtWebGraphAnalog57762FTP Group -------------------------------- wtWebGraphAnalog57762FTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebGraphAnalog57762FTP 1 } wtWebGraphAnalog57762FTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebGraphAnalog57762FTP 2 } wtWebGraphAnalog57762FTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebGraphAnalog57762FTP 3 } wtWebGraphAnalog57762FTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebGraphAnalog57762FTP 4 } wtWebGraphAnalog57762FTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebGraphAnalog57762FTP 5 } wtWebGraphAnalog57762FTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebGraphAnalog57762FTP 6 } wtWebGraphAnalog57762FTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebGraphAnalog57762FTP 7 } -- wtWebGraphAnalog57762Language Group -------------------------------- wtWebGraphAnalog57762LanguageSelect OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Language selection: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : English Bit 0 : German" ::= { wtWebGraphAnalog57762Language 1 } -- wtWebGraphAnalog57762Binary Group -------------------------------- wtWebGraphAnalog57762BinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebGraphAnalog57762Binary 1 } -- Binary Interface Table wtWebGraphAnalog57762BinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57762BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebGraphAnalog57762Binary 2 } wtWebGraphAnalog57762BinaryIfEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57762BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebGraphAnalog57762BinaryModeNo } ::= { wtWebGraphAnalog57762BinaryIfTable 1 } WtWebGraphAnalog57762BinaryIfEntry ::= SEQUENCE { wtWebGraphAnalog57762BinaryModeNo INTEGER } wtWebGraphAnalog57762BinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebGraphAnalog57762BinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebGraphAnalog57762BinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57762BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebGraphAnalog57762Binary 3 } wtWebGraphAnalog57762BinaryEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57762BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebGraphAnalog57762BinaryModeNo } ::= { wtWebGraphAnalog57762BinaryTable 1 } WtWebGraphAnalog57762BinaryEntry ::= SEQUENCE { wtWebGraphAnalog57762BinaryOperationMode OCTET STRING, wtWebGraphAnalog57762BinaryTcpServerLocalPort INTEGER, wtWebGraphAnalog57762BinaryTcpServerInputTrigger OCTET STRING, wtWebGraphAnalog57762BinaryTcpServerApplicationMode OCTET STRING, wtWebGraphAnalog57762BinaryTcpClientLocalPort INTEGER, wtWebGraphAnalog57762BinaryTcpClientServerPort INTEGER, wtWebGraphAnalog57762BinaryTcpClientServerIpAddr OCTET STRING, wtWebGraphAnalog57762BinaryTcpClientServerPassword OCTET STRING, wtWebGraphAnalog57762BinaryTcpClientInactivity INTEGER, wtWebGraphAnalog57762BinaryTcpClientInputTrigger OCTET STRING, wtWebGraphAnalog57762BinaryTcpClientInterval INTEGER, wtWebGraphAnalog57762BinaryTcpClientApplicationMode OCTET STRING, wtWebGraphAnalog57762BinaryUdpPeerLocalPort INTEGER, wtWebGraphAnalog57762BinaryUdpPeerRemotePort INTEGER, wtWebGraphAnalog57762BinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebGraphAnalog57762BinaryUdpPeerInputTrigger OCTET STRING, wtWebGraphAnalog57762BinaryUdpPeerInterval INTEGER, wtWebGraphAnalog57762BinaryUdpPeerApplicationMode OCTET STRING, wtWebGraphAnalog57762BinaryConnectedPort INTEGER, wtWebGraphAnalog57762BinaryConnectedIpAddr IpAddress, wtWebGraphAnalog57762BinaryTcpServerClientHttpPort INTEGER, wtWebGraphAnalog57762BinaryTcpClientServerHttpPort INTEGER, wtWebGraphAnalog57762BinaryTcpServerHysteresis1 OCTET STRING, wtWebGraphAnalog57762BinaryTcpServerHysteresis2 OCTET STRING, wtWebGraphAnalog57762BinaryTcpClientHysteresis1 OCTET STRING, wtWebGraphAnalog57762BinaryTcpClientHysteresis2 OCTET STRING, wtWebGraphAnalog57762BinaryUdpPeerHysteresis1 OCTET STRING, wtWebGraphAnalog57762BinaryUdpPeerHysteresis2 OCTET STRING, wtWebGraphAnalog57762BinaryTcpClientServerUserName OCTET STRING } wtWebGraphAnalog57762BinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebGraphAnalog57762BinaryEntry 1 } wtWebGraphAnalog57762BinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebGraphAnalog57762BinaryEntry 2 } wtWebGraphAnalog57762BinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input states. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Analog inputs 0-1" ::= { wtWebGraphAnalog57762BinaryEntry 3 } wtWebGraphAnalog57762BinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebGraphAnalog57762BinaryEntry 4 } wtWebGraphAnalog57762BinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebGraphAnalog57762BinaryEntry 5 } wtWebGraphAnalog57762BinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebGraphAnalog57762BinaryEntry 6 } wtWebGraphAnalog57762BinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebGraphAnalog57762BinaryEntry 7 } wtWebGraphAnalog57762BinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebGraphAnalog57762BinaryEntry 8 } wtWebGraphAnalog57762BinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebGraphAnalog57762BinaryEntry 9 } wtWebGraphAnalog57762BinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input states. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Analog inputs 0-1" ::= { wtWebGraphAnalog57762BinaryEntry 10 } wtWebGraphAnalog57762BinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebGraphAnalog57762BinaryEntry 11 } wtWebGraphAnalog57762BinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebGraphAnalog57762BinaryEntry 12 } wtWebGraphAnalog57762BinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebGraphAnalog57762BinaryEntry 13 } wtWebGraphAnalog57762BinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebGraphAnalog57762BinaryEntry 14 } wtWebGraphAnalog57762BinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebGraphAnalog57762BinaryEntry 15 } wtWebGraphAnalog57762BinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input states. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Analog inputs 0-1" ::= { wtWebGraphAnalog57762BinaryEntry 16 } wtWebGraphAnalog57762BinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebGraphAnalog57762BinaryEntry 17 } wtWebGraphAnalog57762BinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebGraphAnalog57762BinaryEntry 18 } wtWebGraphAnalog57762BinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebGraphAnalog57762BinaryEntry 19 } wtWebGraphAnalog57762BinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebGraphAnalog57762BinaryEntry 20 } wtWebGraphAnalog57762BinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebGraphAnalog57762BinaryEntry 21 } wtWebGraphAnalog57762BinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebGraphAnalog57762BinaryEntry 22 } wtWebGraphAnalog57762BinaryTcpServerHysteresis1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57762BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be transmitted." ::= { wtWebGraphAnalog57762BinaryEntry 23 } wtWebGraphAnalog57762BinaryTcpServerHysteresis2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57762BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be transmitted." ::= { wtWebGraphAnalog57762BinaryEntry 24 } wtWebGraphAnalog57762BinaryTcpClientHysteresis1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57762BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be transmitted." ::= { wtWebGraphAnalog57762BinaryEntry 25 } wtWebGraphAnalog57762BinaryTcpClientHysteresis2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57762BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be transmitted." ::= { wtWebGraphAnalog57762BinaryEntry 26 } wtWebGraphAnalog57762BinaryUdpPeerHysteresis1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57762BinaryUdpPeerInputTrigger. With a hysteresis of zero any change will be transmitted." ::= { wtWebGraphAnalog57762BinaryEntry 27 } wtWebGraphAnalog57762BinaryUdpPeerHysteresis2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57762BinaryUdpPeerInputTrigger. With a hysteresis of zero any change will be transmitted." ::= { wtWebGraphAnalog57762BinaryEntry 28 } wtWebGraphAnalog57762BinaryTcpClientServerUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by a specific user name within the server. Enter the user name to establish the connection, if a user name entry exists." ::= { wtWebGraphAnalog57762BinaryEntry 29 } -- wtWebGraphAnalog57762MQTT Group -------------------------------- wtWebGraphAnalog57762MQTTEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 7 schaltet MQTT frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0-6: ungenutzt Bit 7 : MQTT enable" ::= { wtWebGraphAnalog57762MQTT 1 } wtWebGraphAnalog57762MQTTBrockerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP-address of the MQTT-Server." ::= { wtWebGraphAnalog57762MQTT 2 } wtWebGraphAnalog57762MQTTUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT login user name." ::= { wtWebGraphAnalog57762MQTT 3 } wtWebGraphAnalog57762MQTTPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT login password." ::= { wtWebGraphAnalog57762MQTT 4 } wtWebGraphAnalog57762MQTTLocalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Local port number." ::= { wtWebGraphAnalog57762MQTT 5 } wtWebGraphAnalog57762MQTTBrokerServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Server port number." ::= { wtWebGraphAnalog57762MQTT 6 } wtWebGraphAnalog57762MQTTInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Ping intervall, if no data has to be send: time in seconds." ::= { wtWebGraphAnalog57762MQTT 7 } wtWebGraphAnalog57762MQTTLastWillEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activate MQTT LastWill message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will enable" ::= { wtWebGraphAnalog57762MQTT 8 } wtWebGraphAnalog57762MQTTLastWillTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will Topic." ::= { wtWebGraphAnalog57762MQTT 9 } wtWebGraphAnalog57762MQTTLastWillMsg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will message." ::= { wtWebGraphAnalog57762MQTT 10 } wtWebGraphAnalog57762MQTTLastWillQoS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded MQTT Publish QoS: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused" ::= { wtWebGraphAnalog57762MQTT 11 } wtWebGraphAnalog57762MQTTLastWillRetain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded MQTT Publish Retain properties: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused" ::= { wtWebGraphAnalog57762MQTT 12 } wtWebGraphAnalog57762MQTTLastWillConnectEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activate MQTT LastWill Connect message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will connect message enable" ::= { wtWebGraphAnalog57762MQTT 13 } wtWebGraphAnalog57762MQTTLastWillConnectMsg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will Connect message will be send with the QoS and Retain settings of the LastWill message." ::= { wtWebGraphAnalog57762MQTT 14 } -- wtWebGraphAnalog57762REST Group -------------------------------- wtWebGraphAnalog57762RESTEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activates REST : Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : REST enable" ::= { wtWebGraphAnalog57762REST 1 } wtWebGraphAnalog57762RESTDigestAuthEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activates Digest-Authentification: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Digest Auth enable" ::= { wtWebGraphAnalog57762REST 2 } -- wtWebGraphAnalog57762Datalogger Group -------------------------------- wtWebGraphAnalog57762LoggerTimebase OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57762Datalogger-15Sec(1), wtWebGraphAnalog57762Datalogger-30Sec(2), wtWebGraphAnalog57762Datalogger-1Min(3), wtWebGraphAnalog57762Datalogger-5Min(4), wtWebGraphAnalog57762Datalogger-15Min(5), wtWebGraphAnalog57762Datalogger-60Min(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Time base of the data logger" ::= { wtWebGraphAnalog57762Datalogger 1 } wtWebGraphAnalog57762LoggerSensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused" ::= { wtWebGraphAnalog57762Datalogger 2 } -- wtWebGraphAnalog57762Alarm Group ---------------------------- wtWebGraphAnalog57762AlarmCount OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebGraphAnalog57762Alarm 1 } -- Alarm Interface Table wtWebGraphAnalog57762AlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57762AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebGraphAnalog57762Alarm 2 } wtWebGraphAnalog57762AlarmIfEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57762AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebGraphAnalog57762AlarmNo } ::= { wtWebGraphAnalog57762AlarmIfTable 1 } WtWebGraphAnalog57762AlarmIfEntry ::= SEQUENCE { wtWebGraphAnalog57762AlarmNo INTEGER } wtWebGraphAnalog57762AlarmNo OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm number." ::= { wtWebGraphAnalog57762AlarmIfEntry 1 } -- Alarm Table wtWebGraphAnalog57762AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57762AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebGraphAnalog57762Alarm 3 } wtWebGraphAnalog57762AlarmEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57762AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebGraphAnalog57762AlarmNo } ::= { wtWebGraphAnalog57762AlarmTable 1 } WtWebGraphAnalog57762AlarmEntry ::= SEQUENCE { wtWebGraphAnalog57762AlarmTrigger OCTET STRING, wtWebGraphAnalog57762AlarmMin1 OCTET STRING, wtWebGraphAnalog57762AlarmMax1 OCTET STRING, wtWebGraphAnalog57762AlarmHysteresis1 OCTET STRING, wtWebGraphAnalog57762AlarmDelay OCTET STRING, wtWebGraphAnalog57762AlarmInterval OCTET STRING, wtWebGraphAnalog57762AlarmEnable OCTET STRING, wtWebGraphAnalog57762AlarmEMailAddr OCTET STRING, wtWebGraphAnalog57762AlarmMailSubject OCTET STRING, wtWebGraphAnalog57762AlarmMailText OCTET STRING, wtWebGraphAnalog57762AlarmManagerIP OCTET STRING, wtWebGraphAnalog57762AlarmTrapText OCTET STRING, wtWebGraphAnalog57762AlarmMailOptions OCTET STRING, wtWebGraphAnalog57762AlarmTcpIpAddr OCTET STRING, wtWebGraphAnalog57762AlarmTcpPort INTEGER, wtWebGraphAnalog57762AlarmTcpText OCTET STRING, wtWebGraphAnalog57762AlarmClearMailSubject OCTET STRING, wtWebGraphAnalog57762AlarmClearMailText OCTET STRING, wtWebGraphAnalog57762AlarmClearTrapText OCTET STRING, wtWebGraphAnalog57762AlarmClearTcpText OCTET STRING, wtWebGraphAnalog57762AlarmMin2 OCTET STRING, wtWebGraphAnalog57762AlarmMax2 OCTET STRING, wtWebGraphAnalog57762AlarmHysteresis2 OCTET STRING, wtWebGraphAnalog57762AlarmSyslogIpAddr OCTET STRING, wtWebGraphAnalog57762AlarmSyslogPort INTEGER, wtWebGraphAnalog57762AlarmSyslogText OCTET STRING, wtWebGraphAnalog57762AlarmSyslogClearText OCTET STRING, wtWebGraphAnalog57762AlarmFtpDataPort OCTET STRING, wtWebGraphAnalog57762AlarmFtpFileName OCTET STRING, wtWebGraphAnalog57762AlarmFtpText OCTET STRING, wtWebGraphAnalog57762AlarmFtpClearText OCTET STRING, wtWebGraphAnalog57762AlarmFtpOption OCTET STRING, wtWebGraphAnalog57762AlarmTimerCron OCTET STRING, wtWebGraphAnalog57762AlarmDeltaTemp OCTET STRING, wtWebGraphAnalog57762AlarmName OCTET STRING, wtWebGraphAnalog57762AlarmActive OCTET STRING, wtWebGraphAnalog57762AlarmHttpReqAuthEnable OCTET STRING, wtWebGraphAnalog57762AlarmHttpReqAuthUser OCTET STRING, wtWebGraphAnalog57762AlarmHttpReqAuthPassword OCTET STRING, wtWebGraphAnalog57762AlarmHttpReqSetUrl OCTET STRING, wtWebGraphAnalog57762AlarmHttpReqClearUrl OCTET STRING, wtWebGraphAnalog57762AlarmHttpReqServerPort INTEGER, wtWebGraphAnalog57762AlarmMqttTopicPath OCTET STRING, wtWebGraphAnalog57762AlarmMqttTopicSetTopic OCTET STRING, wtWebGraphAnalog57762AlarmMqttTopicClear OCTET STRING, wtWebGraphAnalog57762AlarmSensorLostSelection OCTET STRING, wtWebGraphAnalog57762AlarmLimitWindow OCTET STRING, wtWebGraphAnalog57762AlarmSnmpManagerPort INTEGER, wtWebGraphAnalog57762AlarmMqttQoS OCTET STRING, wtWebGraphAnalog57762AlarmMqttRetain OCTET STRING } wtWebGraphAnalog57762AlarmTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused" ::= { wtWebGraphAnalog57762AlarmEntry 1 } wtWebGraphAnalog57762AlarmMin1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum sensor 1 with maximum 3 decimal places." ::= { wtWebGraphAnalog57762AlarmEntry 2 } wtWebGraphAnalog57762AlarmMax1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum sensor 1 with maximum 3 decimal places." ::= { wtWebGraphAnalog57762AlarmEntry 3 } wtWebGraphAnalog57762AlarmHysteresis1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reading changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) with maximum 3 decimal places." ::= { wtWebGraphAnalog57762AlarmEntry 4 } wtWebGraphAnalog57762AlarmDelay OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes)." ::= { wtWebGraphAnalog57762AlarmEntry 5 } wtWebGraphAnalog57762AlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebGraphAnalog57762AlarmEntry 6 } wtWebGraphAnalog57762AlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable" ::= { wtWebGraphAnalog57762AlarmEntry 7 } wtWebGraphAnalog57762AlarmEMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebGraphAnalog57762AlarmEntry 8 } wtWebGraphAnalog57762AlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebGraphAnalog57762AlarmEntry 9 } wtWebGraphAnalog57762AlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: provides the current temperature; n = 1..2. provides the current time." ::= { wtWebGraphAnalog57762AlarmEntry 10 } wtWebGraphAnalog57762AlarmManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the SNMP Manager which accepts the trap." ::= { wtWebGraphAnalog57762AlarmEntry 11 } wtWebGraphAnalog57762AlarmTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebGraphAnalog57762AlarmEntry 12 } wtWebGraphAnalog57762AlarmMailOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused" ::= { wtWebGraphAnalog57762AlarmEntry 13 } wtWebGraphAnalog57762AlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the trap." ::= { wtWebGraphAnalog57762AlarmEntry 14 } wtWebGraphAnalog57762AlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the trap." ::= { wtWebGraphAnalog57762AlarmEntry 15 } wtWebGraphAnalog57762AlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebGraphAnalog57762AlarmEntry 16 } wtWebGraphAnalog57762AlarmClearMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm clear mail." ::= { wtWebGraphAnalog57762AlarmEntry 17 } wtWebGraphAnalog57762AlarmClearMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm clear mail text: provides the current temperature; n = 1..2. provides the current time." ::= { wtWebGraphAnalog57762AlarmEntry 18 } wtWebGraphAnalog57762AlarmClearTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebGraphAnalog57762AlarmEntry 19 } wtWebGraphAnalog57762AlarmClearTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebGraphAnalog57762AlarmEntry 20 } wtWebGraphAnalog57762AlarmMin2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum sensor 2 with maximum 3 decimal places." ::= { wtWebGraphAnalog57762AlarmEntry 21 } wtWebGraphAnalog57762AlarmMax2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum sensor 2 with maximum 2 decimal places." ::= { wtWebGraphAnalog57762AlarmEntry 22 } wtWebGraphAnalog57762AlarmHysteresis2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Hysterese rel. sensor 2 with maximum 3 decimal places." ::= { wtWebGraphAnalog57762AlarmEntry 23 } wtWebGraphAnalog57762AlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebGraphAnalog57762AlarmEntry 24 } wtWebGraphAnalog57762AlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebGraphAnalog57762AlarmEntry 25 } wtWebGraphAnalog57762AlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebGraphAnalog57762AlarmEntry 26 } wtWebGraphAnalog57762AlarmSyslogClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body of a alarm clear message." ::= { wtWebGraphAnalog57762AlarmEntry 27 } wtWebGraphAnalog57762AlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebGraphAnalog57762AlarmEntry 28 } wtWebGraphAnalog57762AlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebGraphAnalog57762AlarmEntry 29 } wtWebGraphAnalog57762AlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebGraphAnalog57762AlarmEntry 30 } wtWebGraphAnalog57762AlarmFtpClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm clear message to store on the FTP server." ::= { wtWebGraphAnalog57762AlarmEntry 31 } wtWebGraphAnalog57762AlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebGraphAnalog57762AlarmEntry 32 } wtWebGraphAnalog57762AlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry defines a time window for alarm 1-8 and a activation time for the report. A time window is definied by start and stop time stamp, seperated by a space or tab. The activation time of the report is defined by a single start time stamp. Each time stamp contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger an action, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas (i.e.: 2,14,22) - a partition within the allowed range (i.e.: 1-5) - step size within a partition of the allowed range (i.e.: 0-59/2 every second minute)." ::= { wtWebGraphAnalog57762AlarmEntry 33 } -- __JB__ wtWebGraphAnalog57762AlarmName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alert name" ::= { wtWebGraphAnalog57762AlarmEntry 39 } -- __JB__ wtWebGraphAnalog57762AlarmActive OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alert active 1 = ON 0 = OFF" ::= { wtWebGraphAnalog57762AlarmEntry 40 } wtWebGraphAnalog57762AlarmHttpReqAuthEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable" ::= { wtWebGraphAnalog57762AlarmEntry 61 } wtWebGraphAnalog57762AlarmHttpReqAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: User" ::= { wtWebGraphAnalog57762AlarmEntry 62 } wtWebGraphAnalog57762AlarmHttpReqAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Password" ::= { wtWebGraphAnalog57762AlarmEntry 63 } wtWebGraphAnalog57762AlarmHttpReqSetUrl OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Set URL" ::= { wtWebGraphAnalog57762AlarmEntry 64 } wtWebGraphAnalog57762AlarmHttpReqClearUrl OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Clear URL" ::= { wtWebGraphAnalog57762AlarmEntry 65 } wtWebGraphAnalog57762AlarmHttpReqServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Server Port" ::= { wtWebGraphAnalog57762AlarmEntry 66 } wtWebGraphAnalog57762AlarmMqttTopicPath OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic path" ::= { wtWebGraphAnalog57762AlarmEntry 67 } wtWebGraphAnalog57762AlarmMqttTopicSetTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic SET message" ::= { wtWebGraphAnalog57762AlarmEntry 68 } wtWebGraphAnalog57762AlarmMqttTopicClear OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic CLEAR message" ::= { wtWebGraphAnalog57762AlarmEntry 69 } wtWebGraphAnalog57762AlarmSensorLostSelection OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Sensor 0" ::= { wtWebGraphAnalog57762AlarmEntry 70 } wtWebGraphAnalog57762AlarmLimitWindow OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If window type is INSIDE the alarm is genereted when the temperature is greater minumum value and lower than maximum value. If window type is OUTSIDE the alarm is generated when the measured value is lower than the minimum value or greater than the maximum value. Binary coded options, select only one option at the same time: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : inside window Bit 0 : outside window" ::= { wtWebGraphAnalog57762AlarmEntry 71 } wtWebGraphAnalog57762AlarmSnmpManagerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebGraphAnalog57762AlarmEntry 76 } wtWebGraphAnalog57762AlarmMqttQoS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused" ::= { wtWebGraphAnalog57762AlarmEntry 77 } wtWebGraphAnalog57762AlarmMqttRetain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused" ::= { wtWebGraphAnalog57762AlarmEntry 78 } -- wtWebGraphAnalog57762GraphicsBase Group ---------------------------- wtWebGraphAnalog57762GraphicsBaseEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5-7: unused" ::= { wtWebGraphAnalog57762GraphicsBase 1 } wtWebGraphAnalog57762GraphicsBaseWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the width of the graphic in pixels." ::= { wtWebGraphAnalog57762GraphicsBase 2 } wtWebGraphAnalog57762GraphicsBaseHeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the height of the graphic in pixels." ::= { wtWebGraphAnalog57762GraphicsBase 3 } wtWebGraphAnalog57762GraphicsBaseFrameColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Frame color definition in RGB." ::= { wtWebGraphAnalog57762GraphicsBase 4 } wtWebGraphAnalog57762GraphicsBaseBackgroundColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Background color definition in RGB." ::= { wtWebGraphAnalog57762GraphicsBase 5 } wtWebGraphAnalog57762GraphicsBasePollingrate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic." ::= { wtWebGraphAnalog57762GraphicsBase 6 } -- wtWebGraphAnalog57762GraphicsSelect Group ---------------------------- wtWebGraphAnalog57762GraphicsSelectDisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused" ::= { wtWebGraphAnalog57762GraphicsSelect 1 } wtWebGraphAnalog57762GraphicsSelectDisplayShowExtrem OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused" ::= { wtWebGraphAnalog57762GraphicsSelect 2 } -- Graph Sensor Color Table wtWebGraphAnalog57762SensorColor2Table OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57762SensorColor2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor colors for the praphical presentation." ::= { wtWebGraphAnalog57762GraphicsSelect 3 } wtWebGraphAnalog57762SensorColor2Entry OBJECT-TYPE SYNTAX WtWebGraphAnalog57762SensorColor2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the sensors." INDEX { wtWebGraphAnalog57762SensorNo } ::= { wtWebGraphAnalog57762SensorColor2Table 1 } WtWebGraphAnalog57762SensorColor2Entry ::= SEQUENCE { wtWebGraphAnalog57762GraphicsSensorColor OCTET STRING, wtWebGraphAnalog57762GraphicsSelectScale OCTET STRING } wtWebGraphAnalog57762GraphicsSensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Color of the sensors at the praphical presention." ::= { wtWebGraphAnalog57762SensorColor2Entry 1 } wtWebGraphAnalog57762GraphicsSelectScale OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2-7: unused" ::= { wtWebGraphAnalog57762SensorColor2Entry 2 } -- wtWebGraphAnalog57762GraphicsScale Group ---------------------------- wtWebGraphAnalog57762GraphicsScaleAutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2-7: unused" ::= { wtWebGraphAnalog57762GraphicsScale 1 } wtWebGraphAnalog57762GraphicsScaleAutoFitEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2-7: unused" ::= { wtWebGraphAnalog57762GraphicsScale 2 } wtWebGraphAnalog57762GraphicsScale1Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Minimum." ::= { wtWebGraphAnalog57762GraphicsScale 3 } wtWebGraphAnalog57762GraphicsScale2Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Minimum." ::= { wtWebGraphAnalog57762GraphicsScale 4 } wtWebGraphAnalog57762GraphicsScale1Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Maximum." ::= { wtWebGraphAnalog57762GraphicsScale 7 } wtWebGraphAnalog57762GraphicsScale2Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Maximum." ::= { wtWebGraphAnalog57762GraphicsScale 8 } wtWebGraphAnalog57762GraphicsScale1Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Unit." ::= { wtWebGraphAnalog57762GraphicsScale 11 } wtWebGraphAnalog57762GraphicsScale2Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Unit." ::= { wtWebGraphAnalog57762GraphicsScale 12 } -- wtWebGraphAnalog57762Ports Group ---------------------------- -- Table wtWebGraphAnalog57762PortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57762PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the sensor number." ::= { wtWebGraphAnalog57762Ports 1 } wtWebGraphAnalog57762PortEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57762PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sensor parameters for the individual sensors." INDEX { wtWebGraphAnalog57762SensorNo } ::= { wtWebGraphAnalog57762PortTable 1 } WtWebGraphAnalog57762PortEntry ::= SEQUENCE { wtWebGraphAnalog57762PortName OCTET STRING, wtWebGraphAnalog57762PortText OCTET STRING, wtWebGraphAnalog57762PortOffset1 OCTET STRING, wtWebGraphAnalog57762SetPoint1 OCTET STRING, wtWebGraphAnalog57762PortOffset2 OCTET STRING, wtWebGraphAnalog57762SetPoint2 OCTET STRING, wtWebGraphAnalog57762PortComment OCTET STRING, wtWebGraphAnalog57762PortSensorSelect OCTET STRING, wtWebGraphAnalog57762PortUnit OCTET STRING, wtWebGraphAnalog57762PortScale0 OCTET STRING, wtWebGraphAnalog57762PortScale100 OCTET STRING, wtWebGraphAnalog57762PortOutputMode OCTET STRING, wtWebGraphAnalog57762PortInputMode OCTET STRING, wtWebGraphAnalog57762PortPresetValue OCTET STRING } wtWebGraphAnalog57762PortName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the sensor." ::= { wtWebGraphAnalog57762PortEntry 1 } wtWebGraphAnalog57762PortText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the sensor." ::= { wtWebGraphAnalog57762PortEntry 2 } wtWebGraphAnalog57762PortOffset1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 3 decimal places at set point 1." ::= { wtWebGraphAnalog57762PortEntry 3 } wtWebGraphAnalog57762SetPoint1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Reference set point 1 in degrees with maximum 3 decimal places." ::= { wtWebGraphAnalog57762PortEntry 4 } wtWebGraphAnalog57762PortOffset2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 3 decimal places at set point 2." ::= { wtWebGraphAnalog57762PortEntry 5 } wtWebGraphAnalog57762SetPoint2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Reference set point 2 in degrees with maximum 3 decimal places." ::= { wtWebGraphAnalog57762PortEntry 6 } wtWebGraphAnalog57762PortComment OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: informations of date, name of operator, reference devices." ::= { wtWebGraphAnalog57762PortEntry 7 } wtWebGraphAnalog57762PortSensorSelect OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options for sensor 1: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : 0-20mA (default) Bit 1 : 4-20mA Bit 2 : Disconnect Bit 3-7: unused" ::= { wtWebGraphAnalog57762PortEntry 8 } wtWebGraphAnalog57762PortUnit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "User scale: displayed unit." ::= { wtWebGraphAnalog57762PortEntry 9 } wtWebGraphAnalog57762PortScale0 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "User scale: displayed value in 1/1000 at 0% full scale range. Range: -999999.999 to 999999.999" ::= { wtWebGraphAnalog57762PortEntry 10 } wtWebGraphAnalog57762PortScale100 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "User scale: displayed value in 1/1000 at 100% full scale range. Range: -999999.999 to 999999.999" ::= { wtWebGraphAnalog57762PortEntry 11 } wtWebGraphAnalog57762PortOutputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. If an output mode is selected, Bit 2 in wtWebGraphAnalog57762PortInputMode will be set automatically. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Output OFF Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebGraphAnalog57762PortEntry 12 } wtWebGraphAnalog57762PortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded input mode defines the individual operation mode for any input. More than one mode must not be selected. If an input mode is selected, Bit 5 in wtWebGraphAnalog57762PortOutputMode will be set automatically. The OCTETS are interpreted bit-by-bit,Bit 0 corresponds to the LSB. OCTET 1: ungenutzt OCTET 2: ungenutzt OCTET 3: ungenutzt OCTET 4: Bit 3-7: unused Bit 2 : I-Output Bit 1 : I-Input, active Bit 0 : I-Input, passive" ::= { wtWebGraphAnalog57762PortEntry 13 } wtWebGraphAnalog57762PortPresetValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This value will be set after reset or initialisation." ::= { wtWebGraphAnalog57762PortEntry 16 } -- wtWebGraphAnalog57762Manufact Group ---------------------------- wtWebGraphAnalog57762MfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebGraphAnalog57762Manufact 1 } wtWebGraphAnalog57762MfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebGraphAnalog57762Manufact 2 } wtWebGraphAnalog57762MfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebGraphAnalog57762Manufact 3 } wtWebGraphAnalog57762MfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebGraphAnalog57762Manufact 4 } wtWebGraphAnalog57762MfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebGraphAnalog57762Manufact 5 } wtWebGraphAnalog57762MfOrderNo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer part number." ::= { wtWebGraphAnalog57762Manufact 6 } -- wtWebGraphAnalog57762Diag Group ---------------------------- wtWebGraphAnalog57762DiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebGraphAnalog57762Diag 1 } wtWebGraphAnalog57762DiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebGraphAnalog57762Diag 2 } wtWebGraphAnalog57762DiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebGraphAnalog57762DiagErrorMessage. Errors are numbered from 1 to wtWebGraphAnalog57762DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebGraphAnalog57762DiagErrorMessage." ::= { wtWebGraphAnalog57762Diag 3 } wtWebGraphAnalog57762DiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebGraphAnalog57762DiagErrorIndex as an index, the appropriate message is available." ::= { wtWebGraphAnalog57762Diag 4 } wtWebGraphAnalog57762DiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebGraphAnalog57762Diag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebGraphAnalog57762Alert1 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 31 wtWebGraphAnalog57762Alert2 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 32 wtWebGraphAnalog57762Alert3 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 33 wtWebGraphAnalog57762Alert4 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 34 wtWebGraphAnalog57762Alert5 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 35 wtWebGraphAnalog57762Alert6 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 36 wtWebGraphAnalog57762Alert7 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 37 wtWebGraphAnalog57762Alert8 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 38 wtWebGraphAnalog57762Alert9 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 91 wtWebGraphAnalog57762Alert10 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 92 wtWebGraphAnalog57762Alert11 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 93 wtWebGraphAnalog57762Alert12 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 94 wtWebGraphAnalog57762Alert13 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 95 wtWebGraphAnalog57762Alert14 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 96 wtWebGraphAnalog57762Alert15 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 97 wtWebGraphAnalog57762Alert16 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 98 wtWebGraphAnalog57762AlertReport TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762AlarmTrapText } DESCRIPTION "This SNMP trap is generated when the report was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Report" --#SUMMARY "Report: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 39 wtWebGraphAnalog57762AlertDiag TRAP-TYPE ENTERPRISE wtWebGraphAnalog57762 VARIABLES { wtWebGraphAnalog57762DiagErrorIndex, wtWebGraphAnalog57762DiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 END