---------------------------------------------------------------------------------------------------------- -- WagoKontakttechnik.mib -- Version: 2.01 -- Date: 2012-03-26 -- Author: WAGO Kontakttechnik GmbH & Co. KG ---------------------------------------------------------------------------------------------------------- WAGO-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 enterprises, IpAddress FROM RFC1155-SMI; -- -- Type definitions -- DisplayString ::= OCTET STRING -- -- Node definitions -- -- 1.3.6.1.4.1.13576 -- 1.3.6.1.4.1.13576 wago OBJECT IDENTIFIER ::= { enterprises 13576 } -- 1.3.6.1.4.1.13576.1 -- 1.3.6.1.4.1.13576.1 wagoCompany OBJECT IDENTIFIER ::= { wago 1 } -- 1.3.6.1.4.1.13576.1.1 -- 1.3.6.1.4.1.13576.1.1 wagoName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Registered name of the company" DEFVAL { "WAGO Kontakttechnik GmbH & Co. KG" } ::= { wagoCompany 1 } -- 1.3.6.1.4.1.13576.1.2 -- 1.3.6.1.4.1.13576.1.2 wagoDescrition OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Description of company" DEFVAL { "WAGO Kontakttechnik GmbH & Co. KG, Hansastr. 27, D-32423 Minden" } ::= { wagoCompany 2 } -- 1.3.6.1.4.1.13576.1.3 -- 1.3.6.1.4.1.13576.1.3 wagoURL OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "URL to webpage of company" DEFVAL { "www.wago.com" } ::= { wagoCompany 3 } -- 1.3.6.1.4.1.13576.10 -- 1.3.6.1.4.1.13576.10 wagoIOProducts OBJECT IDENTIFIER ::= { wago 10 } -- 1.3.6.1.4.1.13576.10.1 -- 1.3.6.1.4.1.13576.10.1 wioCommon OBJECT IDENTIFIER ::= { wagoIOProducts 1 } -- 1.3.6.1.4.1.13576.10.1.1 -- 1.3.6.1.4.1.13576.10.1.1 wioArticleName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "Name of article" DEFVAL { "750-841/000-000" } ::= { wioCommon 1 } -- 1.3.6.1.4.1.13576.10.1.2 -- 1.3.6.1.4.1.13576.10.1.2 wioArticleDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Description of article" DEFVAL { "WAGO Ethernet(10/100MBit)-FBC" } ::= { wioCommon 2 } -- 1.3.6.1.4.1.13576.10.1.3 -- 1.3.6.1.4.1.13576.10.1.3 wioSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Serialnumber of article" DEFVAL { "SNxxxxxxxx-Txxxxxx-mac|0030DExxxxxx" } ::= { wioCommon 3 } -- 1.3.6.1.4.1.13576.10.1.4 -- 1.3.6.1.4.1.13576.10.1.4 wioMacAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "MAC-Address of article" DEFVAL { "0030DExxxxxx" } ::= { wioCommon 4 } -- 1.3.6.1.4.1.13576.10.1.5 -- 1.3.6.1.4.1.13576.10.1.5 wioURLDatasheet OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "URL to datasheet of article" DEFVAL { "http://www.wago.com/wagoweb/documentation/navigate/nm0dc__e.htm#ethernet" } ::= { wioCommon 5 } -- 1.3.6.1.4.1.13576.10.1.6 -- 1.3.6.1.4.1.13576.10.1.6 wioURLManual OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "URL to manual of article" DEFVAL { "http://www.wago.com/wagoweb/documentation/navigate/nm0dc__e.htm#ethernet" } ::= { wioCommon 6 } -- 1.3.6.1.4.1.13576.10.1.10.7 -- 1.3.6.1.4.1.13576.10.1.7 wioDeviceClass OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "device class of the article wioDeviceClass = 10: Controller wioDeviceClass = 20: Koppler wioDeviceClass = 30: Switch wioDeviceClass = 40: Display wioDeviceClass = 50: Sensor wioDeviceClass = 60: Aktor " ::= { wioCommon 7 } -- 1.3.6.1.4.1.13576.10.1.10.8 -- 1.3.6.1.4.1.13576.10.1.8 wioDeviceGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "device group of the article wioDeviceGroup = 10: 750 wioDeviceGroup = 20: Speedway wioDeviceGroup = 30: 758 " ::= { wioCommon 8 } -- 1.3.6.1.4.1.13576.10.1.10 -- 1.3.6.1.4.1.13576.10.1.10 wioVersion OBJECT IDENTIFIER ::= { wioCommon 10 } -- 1.3.6.1.4.1.13576.10.1.10.1 -- 1.3.6.1.4.1.13576.10.1.10.1 wioFirmwareIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of firmwareversion" ::= { wioVersion 1 } -- 1.3.6.1.4.1.13576.10.1.10.2 -- 1.3.6.1.4.1.13576.10.1.10.2 wioHardwareIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of hardwareversion" ::= { wioVersion 2 } -- 1.3.6.1.4.1.13576.10.1.10.3 -- 1.3.6.1.4.1.13576.10.1.10.3 wioFwlIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of softwareversion from firmwareloader" ::= { wioVersion 3 } -- 1.3.6.1.4.1.13576.10.1.10.4 -- 1.3.6.1.4.1.13576.10.1.10.4 wioFirmwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "Complete firmwarestring" ::= { wioVersion 4 } -- 1.3.6.1.4.1.13576.10.1.11 -- 1.3.6.1.4.1.13576.10.1.11 wioRealTimeClock OBJECT IDENTIFIER ::= { wioCommon 11 } -- 1.3.6.1.4.1.13576.10.1.11.1 -- 1.3.6.1.4.1.13576.10.1.11.1 wioRtcDateTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..35)) ACCESS read-write STATUS mandatory DESCRIPTION "Date / time of coupler in UTC as string. For writing date / time use the following string: time 11:22:33 date 13-1-2007" DEFVAL { "time xx:xx:xx date xx-xx-xxxx (UTC)" } ::= { wioRealTimeClock 1 } -- 1.3.6.1.4.1.13576.10.1.11.2 -- 1.3.6.1.4.1.13576.10.1.11.2 wioRtcTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Date / time of coupler in UTC as integer in seconds from 1970-01-01" ::= { wioRealTimeClock 2 } -- 1.3.6.1.4.1.13576.10.1.11.3 -- 1.3.6.1.4.1.13576.10.1.11.3 wioTimezone OBJECT-TYPE SYNTAX INTEGER (-12..12) ACCESS read-write STATUS mandatory DESCRIPTION "Actual timezone of article in hours (-12 - +12)" DEFVAL { 0 } ::= { wioRealTimeClock 3 } -- 1.3.6.1.4.1.13576.10.1.11.4 -- 1.3.6.1.4.1.13576.10.1.11.4 wioRtcHourMode OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Hour mode: 0 = 12h-Mode 1 = 24h-Mode" DEFVAL { 0 } ::= { wioRealTimeClock 4 } -- 1.3.6.1.4.1.13576.10.1.11.5 -- 1.3.6.1.4.1.13576.10.1.11.5 wioRtcBatteryStatus OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "RTC-Battery Status: 0 = ok 1 = battery empty" DEFVAL { 1 } ::= { wioRealTimeClock 5 } -- 1.3.6.1.4.1.13576.10.1.11.6 -- 1.3.6.1.4.1.13576.10.1.11.6 wioRtcDayLightSaving OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Timeoffset of 1 hour: 0 = not offset 1 = offset 1 hour (DayLightSaving)" DEFVAL { 0 } ::= { wioRealTimeClock 6 } -- 1.3.6.1.4.1.13576.10.1.12 -- 1.3.6.1.4.1.13576.10.1.12 wioEthernet OBJECT IDENTIFIER ::= { wioCommon 12 } -- 1.3.6.1.4.1.13576.10.1.12.1 -- 1.3.6.1.4.1.13576.10.1.12.1 wioEthernetMode OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-write STATUS mandatory DESCRIPTION "IP-Configuration of Ethernetconnection: 0 = fix Ip-Address 1 = dynamic IP-Address over Bootp 2 = dynamic IP-Address over DHCP" DEFVAL { 1 } ::= { wioEthernet 1 } -- 1.3.6.1.4.1.13576.10.1.12.2 -- 1.3.6.1.4.1.13576.10.1.12.2 wioIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Actual IP-Address of coupler" ::= { wioEthernet 2 } -- 1.3.6.1.4.1.13576.10.1.12.3 -- 1.3.6.1.4.1.13576.10.1.12.3 wioSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Actual Subnet-Mask of coupler" ::= { wioEthernet 3 } -- 1.3.6.1.4.1.13576.10.1.12.4 -- 1.3.6.1.4.1.13576.10.1.12.4 wioGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Actual Gateway-IP of coupler" ::= { wioEthernet 4 } -- 1.3.6.1.4.1.13576.10.1.12.5 -- 1.3.6.1.4.1.13576.10.1.12.5 wioHostname OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "Actual hostname of coupler" ::= { wioEthernet 5 } -- 1.3.6.1.4.1.13576.10.1.12.6 -- 1.3.6.1.4.1.13576.10.1.12.6 wioDomainName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "Actual domainname of coupler" ::= { wioEthernet 6 } -- 1.3.6.1.4.1.13576.10.1.12.7 -- 1.3.6.1.4.1.13576.10.1.12.7 wioDnsServer1 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP-Address of first DNS-Server" ::= { wioEthernet 7 } -- 1.3.6.1.4.1.13576.10.1.12.8 -- 1.3.6.1.4.1.13576.10.1.12.8 wioDnsServer2 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP-Address of second DNS-Server" ::= { wioEthernet 8 } -- 1.3.6.1.4.1.13576.10.1.20 -- 1.3.6.1.4.1.13576.10.1.20 wioActualStatus OBJECT IDENTIFIER ::= { wioCommon 20 } -- 1.3.6.1.4.1.13576.10.1.20.1 -- 1.3.6.1.4.1.13576.10.1.20.1 wioErrorGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errorgroup of actual error" ::= { wioActualStatus 1 } -- 1.3.6.1.4.1.13576.10.1.20.2 -- 1.3.6.1.4.1.13576.10.1.20.2 wioErrorCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errorcode of actual error" ::= { wioActualStatus 2 } -- 1.3.6.1.4.1.13576.10.1.20.3 -- 1.3.6.1.4.1.13576.10.1.20.3 wioErrorArgument OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errorargument of actual error" ::= { wioActualStatus 3 } -- 1.3.6.1.4.1.13576.10.1.20.4 -- 1.3.6.1.4.1.13576.10.1.20.4 wioErrorDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "Actual error description" ::= { wioActualStatus 4 } -- 1.3.6.1.4.1.13576.10.1.30 -- 1.3.6.1.4.1.13576.10.1.30 wioPlcBrowser OBJECT IDENTIFIER ::= { wioCommon 30 } -- 1.3.6.1.4.1.13576.10.1.30.1 -- 1.3.6.1.4.1.13576.10.1.30.1 wioProjectId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ID of Codesys-Project" ::= { wioPlcBrowser 1 } -- 1.3.6.1.4.1.13576.10.1.30.2 -- 1.3.6.1.4.1.13576.10.1.30.2 wioProjectDate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Date of Codesys-Project" ::= { wioPlcBrowser 2 } -- 1.3.6.1.4.1.13576.10.1.30.3 -- 1.3.6.1.4.1.13576.10.1.30.3 wioProjectName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "Name of Codesys-Project" ::= { wioPlcBrowser 3 } -- 1.3.6.1.4.1.13576.10.1.30.4 -- 1.3.6.1.4.1.13576.10.1.30.4 wioProjectTitle OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "Title of Codesys-Project" ::= { wioPlcBrowser 4 } -- 1.3.6.1.4.1.13576.10.1.30.5 -- 1.3.6.1.4.1.13576.10.1.30.5 wioProjectVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "Version of Codesys-Project" ::= { wioPlcBrowser 5 } -- 1.3.6.1.4.1.13576.10.1.30.6 -- 1.3.6.1.4.1.13576.10.1.30.6 wioProjectAuthor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "Author of Codesys-Project" ::= { wioPlcBrowser 6 } -- 1.3.6.1.4.1.13576.10.1.30.7 -- 1.3.6.1.4.1.13576.10.1.30.7 wioProjectDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "Description of Codesys-Project" ::= { wioPlcBrowser 7 } -- 1.3.6.1.4.1.13576.10.1.30.8 -- 1.3.6.1.4.1.13576.10.1.30.8 wioNumberOfIecTasks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of IEC-Tasks in the Codesys-Project" ::= { wioPlcBrowser 8 } -- 1.3.6.1.4.1.13576.10.1.30.9 -- 1.3.6.1.4.1.13576.10.1.30.9 wioIecTaskTable OBJECT-TYPE SYNTAX SEQUENCE OF WioIecTaskEntry ACCESS not-accessible STATUS mandatory ::= { wioPlcBrowser 9 } -- 1.3.6.1.4.1.13576.10.1.30.9.1 -- 1.3.6.1.4.1.13576.10.1.30.9.1 wioIecTaskEntry OBJECT-TYPE SYNTAX WioIecTaskEntry ACCESS not-accessible STATUS mandatory INDEX { wioIecTaskId } ::= { wioIecTaskTable 1 } WioIecTaskEntry ::= SEQUENCE { wioIecTaskId INTEGER, wioIecTaskName DisplayString, wioIecTaskStatus INTEGER, wioIecTaskMode INTEGER, wioIecTaskPriority INTEGER, wioIecTaskInterval INTEGER, wioIecTaskEvent INTEGER, wioIecTaskCycleCount INTEGER, wioIecTaskCycleTime INTEGER, wioIecTaskCycleTimeMin INTEGER, wioIecTaskCycleTimeMax INTEGER, wioIecTaskCycleTimeAvg INTEGER } -- 1.3.6.1.4.1.13576.10.1.30.9.1.1 -- 1.3.6.1.4.1.13576.10.1.30.9.1.1 wioIecTaskId OBJECT-TYPE SYNTAX INTEGER (1..29) ACCESS read-only STATUS mandatory DESCRIPTION "ID of IEC-Task in the Codesys-Project" ::= { wioIecTaskEntry 1 } -- 1.3.6.1.4.1.13576.10.1.30.9.1.2 -- 1.3.6.1.4.1.13576.10.1.30.9.1.2 wioIecTaskName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "Name of IEC-Task in the Codesys-Project" ::= { wioIecTaskEntry 2 } -- 1.3.6.1.4.1.13576.10.1.30.9.1.3 -- 1.3.6.1.4.1.13576.10.1.30.9.1.3 wioIecTaskStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Status of IEC-Task in the Codesys-Project" ::= { wioIecTaskEntry 3 } -- 1.3.6.1.4.1.13576.10.1.30.9.1.4 -- 1.3.6.1.4.1.13576.10.1.30.9.1.4 wioIecTaskMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Mode of IEC-Task in the Codesys-Project" ::= { wioIecTaskEntry 4 } -- 1.3.6.1.4.1.13576.10.1.30.9.1.5 -- 1.3.6.1.4.1.13576.10.1.30.9.1.5 wioIecTaskPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Priority of IEC-Task in the Codesys-Project" ::= { wioIecTaskEntry 5 } -- 1.3.6.1.4.1.13576.10.1.30.9.1.6 -- 1.3.6.1.4.1.13576.10.1.30.9.1.6 wioIecTaskInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Interval of cyclic IEC-Task in the Codesys-Project" ::= { wioIecTaskEntry 6 } -- 1.3.6.1.4.1.13576.10.1.30.9.1.7 -- 1.3.6.1.4.1.13576.10.1.30.9.1.7 wioIecTaskEvent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Event for IEC-Task in the Codesys-Project" ::= { wioIecTaskEntry 7 } -- 1.3.6.1.4.1.13576.10.1.30.9.1.8 -- 1.3.6.1.4.1.13576.10.1.30.9.1.8 wioIecTaskCycleCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Count of IEC-Task in the Codesys-Project" ::= { wioIecTaskEntry 8 } -- 1.3.6.1.4.1.13576.10.1.30.9.1.9 -- 1.3.6.1.4.1.13576.10.1.30.9.1.9 wioIecTaskCycleTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Last cycletime of IEC-Task in the Codesys-Project" ::= { wioIecTaskEntry 9 } -- 1.3.6.1.4.1.13576.10.1.30.9.1.10 -- 1.3.6.1.4.1.13576.10.1.30.9.1.10 wioIecTaskCycleTimeMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minimal cycletime of IEC-Task in the Codesys-Project" ::= { wioIecTaskEntry 10 } -- 1.3.6.1.4.1.13576.10.1.30.9.1.11 -- 1.3.6.1.4.1.13576.10.1.30.9.1.11 wioIecTaskCycleTimeMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximal cycletime of IEC-Task in the Codesys-Project" ::= { wioIecTaskEntry 11 } -- 1.3.6.1.4.1.13576.10.1.30.9.1.12 -- 1.3.6.1.4.1.13576.10.1.30.9.1.12 wioIecTaskCycleTimeAvg OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average cycletime of IEC-Task in the Codesys-Project" ::= { wioIecTaskEntry 12 } -- 1.3.6.1.4.1.13576.10.1.40 -- 1.3.6.1.4.1.13576.10.1.40 wioEthernetProtocols OBJECT IDENTIFIER ::= { wioCommon 40 } -- 1.3.6.1.4.1.13576.10.1.40.1 -- 1.3.6.1.4.1.13576.10.1.40.1 wioHttp OBJECT IDENTIFIER ::= { wioEthernetProtocols 1 } -- 1.3.6.1.4.1.13576.10.1.40.1.1 -- 1.3.6.1.4.1.13576.10.1.40.1.1 wioHttpEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Enable / Disable the port of the webserver: 0 = port of webserver disable 1 = port of webserver enable" DEFVAL { 1 } ::= { wioHttp 1 } -- 1.3.6.1.4.1.13576.10.1.40.1.2 -- 1.3.6.1.4.1.13576.10.1.40.1.2 wioHttpAuthenticationEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Enable / disable the authentication on the websides: 0 = authentication disabled 1 = authentication enable" DEFVAL { 1 } ::= { wioHttp 2 } -- 1.3.6.1.4.1.13576.10.1.40.1.3 -- 1.3.6.1.4.1.13576.10.1.40.1.3 wioHttpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port of the Http-Web-Server" DEFVAL { 80 } ::= { wioHttp 3 } -- 1.3.6.1.4.1.13576.10.1.40.2 -- 1.3.6.1.4.1.13576.10.1.40.2 wioFtp OBJECT IDENTIFIER ::= { wioEthernetProtocols 2 } -- 1.3.6.1.4.1.13576.10.1.40.2.1 -- 1.3.6.1.4.1.13576.10.1.40.2.1 wioFtpEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Enable / Disable the port of the ftpserver 0 = port of ftpserver disable 1 = port of ftpserver enable" DEFVAL { 1 } ::= { wioFtp 1 } -- 1.3.6.1.4.1.13576.10.1.40.3 -- 1.3.6.1.4.1.13576.10.1.40.3 wioSntp OBJECT IDENTIFIER ::= { wioEthernetProtocols 3 } -- 1.3.6.1.4.1.13576.10.1.40.3.1 -- 1.3.6.1.4.1.13576.10.1.40.3.1 wioSntpEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Enable / Disable the port of the SNTPserver 0 = port of SNTPserver disable 1 = port of SNTPserver enable" DEFVAL { 1 } ::= { wioSntp 1 } -- 1.3.6.1.4.1.13576.10.1.40.3.2 -- 1.3.6.1.4.1.13576.10.1.40.3.2 wioSntpServerAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP-Address of SNTP-Server" DEFVAL { 0 } ::= { wioSntp 2 } -- 1.3.6.1.4.1.13576.10.1.40.3.3 -- 1.3.6.1.4.1.13576.10.1.40.3.3 wioSntpClientIntervall OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Interval to pool SNTP-Manager" DEFVAL { 0 } ::= { wioSntp 3 } -- 1.3.6.1.4.1.13576.10.1.40.3.4 -- 1.3.6.1.4.1.13576.10.1.40.3.4 wioSntpClientTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Timeout to corrupt SNTP answer" DEFVAL { 2000 } ::= { wioSntp 4 } -- 1.3.6.1.4.1.13576.10.1.40.3.5 -- 1.3.6.1.4.1.13576.10.1.40.3.5 wioSntpClientDayLightSaving OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Timeoffset of 1 hour: 0 = not offset 1 = offset 1 hour (DayLightSaving)" DEFVAL { 0 } ::= { wioSntp 5 } -- 1.3.6.1.4.1.13576.10.1.40.4 -- 1.3.6.1.4.1.13576.10.1.40.4 wioSnmp OBJECT IDENTIFIER ::= { wioEthernetProtocols 4 } -- 1.3.6.1.4.1.13576.10.1.40.4.1 -- 1.3.6.1.4.1.13576.10.1.40.4.1 wioSnmpEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Enable / Disable the port of the SNMPserver 0 = port of SNMPserver disable 1 = port of SNMPserver enable" DEFVAL { 1 } ::= { wioSnmp 1 } -- 1.3.6.1.4.1.13576.10.1.40.4.2 -- 1.3.6.1.4.1.13576.10.1.40.4.2 wioSnmpV1V2c OBJECT IDENTIFIER ::= { wioSnmp 2 } -- 1.3.6.1.4.1.13576.10.1.40.4.2.1 -- 1.3.6.1.4.1.13576.10.1.40.4.2.1 wioSnmpEnableV1V2 OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Enable / Disable the management for SNMP version 1 and version 2c 0 = disable 1 = enable" ::= { wioSnmpV1V2c 1 } -- 1.3.6.1.4.1.13576.10.1.40.4.2.2 -- 1.3.6.1.4.1.13576.10.1.40.4.2.2 wioLocalCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { wioSnmpV1V2c 2 } -- 1.3.6.1.4.1.13576.10.1.40.4.2.3 -- 1.3.6.1.4.1.13576.10.1.40.4.2.3 wioTrapReceiverV1V2Table OBJECT-TYPE SYNTAX SEQUENCE OF WioTrapReceiverV1V2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION " " ::= { wioSnmpV1V2c 3 } -- 1.3.6.1.4.1.13576.10.1.40.4.2.3.1 -- 1.3.6.1.4.1.13576.10.1.40.4.2.3.1 wioTrapReceiverV1V2Entry OBJECT-TYPE SYNTAX WioTrapReceiverV1V2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { wioTrapReceiverIndex } ::= { wioTrapReceiverV1V2Table 1 } WioTrapReceiverV1V2Entry ::= SEQUENCE { wioTrapReceiverIndex INTEGER, wioTrapReceiverIpAddress IpAddress, wioTrapReceiverCommunityName DisplayString, wioTrapReceiverTrapVersion INTEGER } -- 1.3.6.1.4.1.13576.10.1.40.4.2.3.1.1 -- 1.3.6.1.4.1.13576.10.1.40.4.2.3.1.1 wioTrapReceiverIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { wioTrapReceiverV1V2Entry 1 } -- 1.3.6.1.4.1.13576.10.1.40.4.2.3.1.2 -- 1.3.6.1.4.1.13576.10.1.40.4.2.3.1.2 wioTrapReceiverIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { wioTrapReceiverV1V2Entry 2 } -- 1.3.6.1.4.1.13576.10.1.40.4.2.3.1.3 -- 1.3.6.1.4.1.13576.10.1.40.4.2.3.1.3 wioTrapReceiverCommunityName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { wioTrapReceiverV1V2Entry 3 } -- 1.3.6.1.4.1.13576.10.1.40.4.2.3.1.4 -- 1.3.6.1.4.1.13576.10.1.40.4.2.3.1.4 wioTrapReceiverTrapVersion OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { wioTrapReceiverV1V2Entry 4 } -- 1.3.6.1.4.1.13576.10.1.40.4.3 -- 1.3.6.1.4.1.13576.10.1.40.4.3 wioSnmpV3Usm OBJECT IDENTIFIER ::= { wioSnmp 3 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.1 -- 1.3.6.1.4.1.13576.10.1.40.4.3.1 wioSnmp1UserEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Enables / Disables first SNMPv3 User" DEFVAL { 1 } ::= { wioSnmpV3Usm 1 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.2 -- 1.3.6.1.4.1.13576.10.1.40.4.3.2 wioSnmp1AuthenticationTyp OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-write STATUS mandatory DESCRIPTION "Athentication-Typ for first SNMPv3-user: 0 = no Authentication 1 = MD5 Authentication 2 = SHA1 Authentication" DEFVAL { 1 } ::= { wioSnmpV3Usm 2 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.3 -- 1.3.6.1.4.1.13576.10.1.40.4.3.3 wioSnmp1AuthenticationName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "Authentication name for first SNMPv3-user" DEFVAL { "SecurityName" } ::= { wioSnmpV3Usm 3 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.4 -- 1.3.6.1.4.1.13576.10.1.40.4.3.4 wioSnmp1AuthenticationKey OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "Authentication key for first SNMPv3-user" DEFVAL { "AuthenticationKey" } ::= { wioSnmpV3Usm 4 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.5 -- 1.3.6.1.4.1.13576.10.1.40.4.3.5 wioSnmp1PrivacyEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Disable / Enable Data Encryption for first SNMPv3-user: 0 = no Encryption 1 = DES Encryption" DEFVAL { 1 } ::= { wioSnmpV3Usm 5 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.6 -- 1.3.6.1.4.1.13576.10.1.40.4.3.6 wioSnmp1PrivacyKey OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "Privacy key for SNMPv3 for first SNMPv3-user" DEFVAL { "PrivacyKey" } ::= { wioSnmpV3Usm 6 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.7 -- 1.3.6.1.4.1.13576.10.1.40.4.3.7 wioSnmp1NotificationEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Enables / Disables notification (SNMPv3-traps) with SNMPv3 User" DEFVAL { 1 } ::= { wioSnmpV3Usm 7 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.8 -- 1.3.6.1.4.1.13576.10.1.40.4.3.8 wioSnmp1NotificationReceiverIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Receiver-IP-Address for notification (SNMPv3-traps) with SNMPv3 User" DEFVAL { 'C0A80101'h } ::= { wioSnmpV3Usm 8 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.9 -- 1.3.6.1.4.1.13576.10.1.40.4.3.9 wioSnmp2UserEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Enables / Disables second SNMPv3 User" DEFVAL { 0 } ::= { wioSnmpV3Usm 9 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.10 -- 1.3.6.1.4.1.13576.10.1.40.4.3.10 wioSnmp2AuthenticationTyp OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-write STATUS mandatory DESCRIPTION "Athentication-Typ for second SNMPv3-user: 0 = no Authentication 1 = MD5 Authentication 2 = SHA1 Authentication" DEFVAL { 1 } ::= { wioSnmpV3Usm 10 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.11 -- 1.3.6.1.4.1.13576.10.1.40.4.3.11 wioSnmp2AuthenticationName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "Authentication name for second SNMPv3-user" DEFVAL { "SecurityName" } ::= { wioSnmpV3Usm 11 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.12 -- 1.3.6.1.4.1.13576.10.1.40.4.3.12 wioSnmp2AuthenticationKey OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "Authentication key for second SNMPv3-user" DEFVAL { "AuthenticationKey" } ::= { wioSnmpV3Usm 12 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.13 -- 1.3.6.1.4.1.13576.10.1.40.4.3.13 wioSnmp2PrivacyEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Privacy key for SNMPv3 for second SNMPv3-user" DEFVAL { 1 } ::= { wioSnmpV3Usm 13 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.14 -- 1.3.6.1.4.1.13576.10.1.40.4.3.14 wioSnmp2PrivacyKey OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "Privacy key for SNMPv3 for second SNMPv3-user" DEFVAL { "PrivacyKey" } ::= { wioSnmpV3Usm 14 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.15 -- 1.3.6.1.4.1.13576.10.1.40.4.3.15 wioSnmp2NotificationEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Enables / Disables notification (SNMPv3-traps) with SNMPv3 User" DEFVAL { 0 } ::= { wioSnmpV3Usm 15 } -- 1.3.6.1.4.1.13576.10.1.40.4.3.16 -- 1.3.6.1.4.1.13576.10.1.40.4.3.16 wioSnmp2NotificationReceiverIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Receiver-IP-Address for notification (SNMPv3-traps) with SNMPv3 User" DEFVAL { '00000000'h } ::= { wioSnmpV3Usm 16 } -- 1.3.6.1.4.1.13576.10.1.40.4.4 -- 1.3.6.1.4.1.13576.10.1.40.4.4 wioTrapMessages OBJECT IDENTIFIER ::= { wioSnmp 4 } -- 1.3.6.1.4.1.13576.10.1.40.4.4.1 -- 1.3.6.1.4.1.13576.10.1.40.4.4.1 wioTrapKbusError OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 1.SNMP-Trap" DEFVAL { "Kbus Error" } ::= { wioTrapMessages 1 } -- 1.3.6.1.4.1.13576.10.1.40.4.4.2 -- 1.3.6.1.4.1.13576.10.1.40.4.4.2 wioTrapPlcStart OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 2.SNMP-Trap" DEFVAL { "Plc Start" } ::= { wioTrapMessages 2 } -- 1.3.6.1.4.1.13576.10.1.40.4.4.3 -- 1.3.6.1.4.1.13576.10.1.40.4.4.3 wioTrapPlcStop OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 3.SNMP-Trap" DEFVAL { "Plc Stop" } ::= { wioTrapMessages 3 } -- 1.3.6.1.4.1.13576.10.1.40.4.4.4 -- 1.3.6.1.4.1.13576.10.1.40.4.4.4 wioTrapPlcReset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 4.SNMP-Trap" DEFVAL { "Plc Reset" } ::= { wioTrapMessages 4 } -- 1.3.6.1.4.1.13576.10.1.40.4.4.5 -- 1.3.6.1.4.1.13576.10.1.40.4.4.5 wioTrapPlcSoftwareWatchdog OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 5.SNMP-Trap" DEFVAL { "Plc Software Watchdog" } ::= { wioTrapMessages 5 } -- 1.3.6.1.4.1.13576.10.1.40.4.4.6 -- 1.3.6.1.4.1.13576.10.1.40.4.4.6 wioTrapPlcDivideByZero OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 6.SNMP-Trap" DEFVAL { "Plc Division By Zero" } ::= { wioTrapMessages 6 } -- 1.3.6.1.4.1.13576.10.1.40.4.4.7 -- 1.3.6.1.4.1.13576.10.1.40.4.4.7 wioTrapPlcOnlineChange OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 7.SNMP-Trap" DEFVAL { "Plc Online Change" } ::= { wioTrapMessages 7 } -- 1.3.6.1.4.1.13576.10.1.40.4.4.8 -- 1.3.6.1.4.1.13576.10.1.40.4.4.8 wioTrapPlcDownload OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 8.SNMP-Trap" DEFVAL { "Plc Download Programm" } ::= { wioTrapMessages 8 } -- 1.3.6.1.4.1.13576.10.1.40.4.4.9 -- 1.3.6.1.4.1.13576.10.1.40.4.4.9 wioTrapPlcLogin OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 9.SNMP-Trap" DEFVAL { "Plc Login" } ::= { wioTrapMessages 9 } -- 1.3.6.1.4.1.13576.10.1.40.4.4.10 -- 1.3.6.1.4.1.13576.10.1.40.4.4.10 wioTrapPlcLogout OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 10.SNMP-Trap" DEFVAL { "Plc Logout" } ::= { wioTrapMessages 10 } -- 1.3.6.1.4.1.13576.10.1.40.4.5 -- 1.3.6.1.4.1.13576.10.1.40.4.5 wioUserTrapMessages OBJECT IDENTIFIER ::= { wioSnmp 5 } -- 1.3.6.1.4.1.13576.10.1.40.4.5.1 -- 1.3.6.1.4.1.13576.10.1.40.4.5.1 wioUserTrapMsg1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 1.SNMP-Trap" ::= { wioUserTrapMessages 1 } -- 1.3.6.1.4.1.13576.10.1.40.4.5.2 -- 1.3.6.1.4.1.13576.10.1.40.4.5.2 wioUserTrapMsg2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 1.SNMP-Trap" ::= { wioUserTrapMessages 2 } -- 1.3.6.1.4.1.13576.10.1.40.4.5.3 -- 1.3.6.1.4.1.13576.10.1.40.4.5.3 wioUserTrapMsg3 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 1.SNMP-Trap" ::= { wioUserTrapMessages 3 } -- 1.3.6.1.4.1.13576.10.1.40.4.5.4 -- 1.3.6.1.4.1.13576.10.1.40.4.5.4 wioUserTrapMsg4 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 1.SNMP-Trap" ::= { wioUserTrapMessages 4 } -- 1.3.6.1.4.1.13576.10.1.40.4.5.5 -- 1.3.6.1.4.1.13576.10.1.40.4.5.5 wioUserTrapMsg5 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 1.SNMP-Trap" ::= { wioUserTrapMessages 5 } -- 1.3.6.1.4.1.13576.10.1.40.4.5.6 -- 1.3.6.1.4.1.13576.10.1.40.4.5.6 wioUserTrapMsg6 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 1.SNMP-Trap" ::= { wioUserTrapMessages 6 } -- 1.3.6.1.4.1.13576.10.1.40.4.5.7 -- 1.3.6.1.4.1.13576.10.1.40.4.5.7 wioUserTrapMsg7 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 1.SNMP-Trap" ::= { wioUserTrapMessages 7 } -- 1.3.6.1.4.1.13576.10.1.40.4.5.8 -- 1.3.6.1.4.1.13576.10.1.40.4.5.8 wioUserTrapMsg8 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 1.SNMP-Trap" ::= { wioUserTrapMessages 8 } -- 1.3.6.1.4.1.13576.10.1.40.4.5.9 -- 1.3.6.1.4.1.13576.10.1.40.4.5.9 wioUserTrapMsg9 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 1.SNMP-Trap" ::= { wioUserTrapMessages 9 } -- 1.3.6.1.4.1.13576.10.1.40.4.5.10 -- 1.3.6.1.4.1.13576.10.1.40.4.5.10 wioUserTrapMsg10 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "String for 1.SNMP-Trap" ::= { wioUserTrapMessages 10 } -- 1.3.6.1.4.1.13576.10.1.40.5 -- 1.3.6.1.4.1.13576.10.1.40.5 wioCoDeSys OBJECT IDENTIFIER ::= { wioEthernetProtocols 5 } -- 1.3.6.1.4.1.13576.10.1.40.5.1 -- 1.3.6.1.4.1.13576.10.1.40.5.1 wioCoDeSysEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Enable / Disable the port of the CoDeSysServer 0 = port of CoDeSysServer disable 1 = port of CoDeSysServer enable" DEFVAL { 1 } ::= { wioCoDeSys 1 } -- 1.3.6.1.4.1.13576.10.1.40.6 -- 1.3.6.1.4.1.13576.10.1.40.6 wioModbus OBJECT IDENTIFIER ::= { wioEthernetProtocols 6 } -- 1.3.6.1.4.1.13576.10.1.40.6.1 -- 1.3.6.1.4.1.13576.10.1.40.6.1 wioModbusTcpEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Enable / Disable the port of the Modbus-TCP-Server 0 = port of Modbus-TCP-Server disable 1 = port of Modbus-TCP-Server enable" DEFVAL { 1 } ::= { wioModbus 1 } -- 1.3.6.1.4.1.13576.10.1.40.6.2 -- 1.3.6.1.4.1.13576.10.1.40.6.2 wioModbusUdbEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Enable / Disable the port of the Modbus-UDP-Server 0 = port of Modbus-UDP-Server disable 1 = port of Modbus-UDP-Server enable" DEFVAL { 1 } ::= { wioModbus 2 } -- 1.3.6.1.4.1.13576.10.1.40.6.3 -- 1.3.6.1.4.1.13576.10.1.40.6.3 wioMaxConnections OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximal count of modbus connections" DEFVAL { 15 } ::= { wioModbus 3 } -- 1.3.6.1.4.1.13576.10.1.40.6.4 -- 1.3.6.1.4.1.13576.10.1.40.6.4 wioConnectionTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Timeout of the modbus connection" DEFVAL { 600 } ::= { wioModbus 4 } -- 1.3.6.1.4.1.13576.10.1.40.6.5 -- 1.3.6.1.4.1.13576.10.1.40.6.5 wioModbusWatchdogMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the modbus watchdog" DEFVAL { 0 } ::= { wioModbus 5 } -- 1.3.6.1.4.1.13576.10.1.40.6.6 -- 1.3.6.1.4.1.13576.10.1.40.6.6 wioModbusWatchdogTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Timeout of the modbus watchdog" DEFVAL { 100 } ::= { wioModbus 6 } -- 1.3.6.1.4.1.13576.10.1.40.6.7 -- 1.3.6.1.4.1.13576.10.1.40.6.7 wioFreeModbusSockets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unused and free modbus connections" DEFVAL { 15 } ::= { wioModbus 7 } -- 1.3.6.1.4.1.13576.10.1.40.6.8 -- 1.3.6.1.4.1.13576.10.1.40.6.8 wioModbusConnectionTable OBJECT-TYPE SYNTAX SEQUENCE OF WioModbusConnectionEntry ACCESS not-accessible STATUS mandatory ::= { wioModbus 8 } -- 1.3.6.1.4.1.13576.10.1.40.6.8.1 -- 1.3.6.1.4.1.13576.10.1.40.6.8.1 wioModbusConnectionEntry OBJECT-TYPE SYNTAX WioModbusConnectionEntry ACCESS not-accessible STATUS mandatory INDEX { wioModbusConnectionIndex } ::= { wioModbusConnectionTable 1 } WioModbusConnectionEntry ::= SEQUENCE { wioModbusConnectionIndex INTEGER, wioModbusConnectionIp IpAddress, wioModbusConnectionPort INTEGER } -- 1.3.6.1.4.1.13576.10.1.40.6.8.1.1 -- 1.3.6.1.4.1.13576.10.1.40.6.8.1.1 wioModbusConnectionIndex OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Index of modbus connection" ::= { wioModbusConnectionEntry 1 } -- 1.3.6.1.4.1.13576.10.1.40.6.8.1.2 -- 1.3.6.1.4.1.13576.10.1.40.6.8.1.2 wioModbusConnectionIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP-Address of modbus connection" ::= { wioModbusConnectionEntry 2 } -- 1.3.6.1.4.1.13576.10.1.40.6.8.1.3 -- 1.3.6.1.4.1.13576.10.1.40.6.8.1.3 wioModbusConnectionPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port of modbus connection" ::= { wioModbusConnectionEntry 3 } -- 1.3.6.1.4.1.13576.10.1.40.7 -- 1.3.6.1.4.1.13576.10.1.40.7 wioEthernetIp OBJECT IDENTIFIER ::= { wioEthernetProtocols 7 } -- 1.3.6.1.4.1.13576.10.1.40.7.1 -- 1.3.6.1.4.1.13576.10.1.40.7.1 wioEthernetIpEnable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Enable / Disable the port of the EthernetIPServer 0 = port of EthernetIPServer disable 1 = port of EthernetIPServer enable" DEFVAL { 0 } ::= { wioEthernetIp 1 } -- 1.3.6.1.4.1.13576.10.1.40.7.2 -- 1.3.6.1.4.1.13576.10.1.40.7.2 wioEthernetIpVariablesInputCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory ::= { wioEthernetIp 2 } -- 1.3.6.1.4.1.13576.10.1.40.7.3 -- 1.3.6.1.4.1.13576.10.1.40.7.3 wioEthernetIpVariablesOutputCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory ::= { wioEthernetIp 3 } -- 1.3.6.1.4.1.13576.10.1.40.7.4 -- 1.3.6.1.4.1.13576.10.1.40.7.4 wioEthernetIpVariablesPlcInputCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory ::= { wioEthernetIp 4 } -- 1.3.6.1.4.1.13576.10.1.40.7.5 -- 1.3.6.1.4.1.13576.10.1.40.7.5 wioEthernetIpVariablesPlcInputOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory ::= { wioEthernetIp 5 } -- 1.3.6.1.4.1.13576.10.1.40.7.6 -- 1.3.6.1.4.1.13576.10.1.40.7.6 wioEthernetIpVariablesPlcOutputCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory ::= { wioEthernetIp 6 } -- 1.3.6.1.4.1.13576.10.1.40.7.7 -- 1.3.6.1.4.1.13576.10.1.40.7.7 wioEthernetIpVariablesPlcOutputOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory ::= { wioEthernetIp 7 } -- 1.3.6.1.4.1.13576.10.1.40.7.8 -- 1.3.6.1.4.1.13576.10.1.40.7.8 wioEthernetIpRunIdleHeaderOrginatorToTarget OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory ::= { wioEthernetIp 8 } -- 1.3.6.1.4.1.13576.10.1.40.7.9 -- 1.3.6.1.4.1.13576.10.1.40.7.9 wioEthernetIpRunIdleHeaderTargetToOrginator OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory ::= { wioEthernetIp 9 } -- 1.3.6.1.4.1.13576.10.1.50 -- 1.3.6.1.4.1.13576.10.1.50 wioProcessImage OBJECT IDENTIFIER ::= { wioCommon 50 } -- 1.3.6.1.4.1.13576.10.1.50.1 -- 1.3.6.1.4.1.13576.10.1.50.1 wioModulCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Count of modules" ::= { wioProcessImage 1 } -- 1.3.6.1.4.1.13576.10.1.50.2 -- 1.3.6.1.4.1.13576.10.1.50.2 wioAnalogOutLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of analog output process datas" ::= { wioProcessImage 2 } -- 1.3.6.1.4.1.13576.10.1.50.3 -- 1.3.6.1.4.1.13576.10.1.50.3 wioAnalogInLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of analog input process datas" ::= { wioProcessImage 3 } -- 1.3.6.1.4.1.13576.10.1.50.4 -- 1.3.6.1.4.1.13576.10.1.50.4 wioDigitalOutLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of digital output process datas" ::= { wioProcessImage 4 } -- 1.3.6.1.4.1.13576.10.1.50.5 -- 1.3.6.1.4.1.13576.10.1.50.5 wioDigitalInLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of digital input process datas" ::= { wioProcessImage 5 } -- 1.3.6.1.4.1.13576.10.1.50.6 -- 1.3.6.1.4.1.13576.10.1.50.6 wioDigitalOutOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Offset of digital output process datas" ::= { wioProcessImage 6 } -- 1.3.6.1.4.1.13576.10.1.50.7 -- 1.3.6.1.4.1.13576.10.1.50.7 wioDigitalInOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Offset of digital input process datas" ::= { wioProcessImage 7 } -- 1.3.6.1.4.1.13576.10.1.50.8 -- 1.3.6.1.4.1.13576.10.1.50.8 wioModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF WioModuleEntry ACCESS not-accessible STATUS mandatory ::= { wioProcessImage 8 } -- 1.3.6.1.4.1.13576.10.1.50.8.1 -- 1.3.6.1.4.1.13576.10.1.50.8.1 wioModuleEntry OBJECT-TYPE SYNTAX WioModuleEntry ACCESS not-accessible STATUS mandatory INDEX { wioModuleNumber } ::= { wioModuleTable 1 } WioModuleEntry ::= SEQUENCE { wioModuleNumber INTEGER, wioModuleName DisplayString, wioModuleType INTEGER, wioModuleCount INTEGER, wioModuleAlternativeFormat INTEGER, wioModuleAnalogOutLength INTEGER, wioModuleAnalogInLength INTEGER, wioModuleDigitalOutLength INTEGER, wioModuleDigitalInLength INTEGER } -- 1.3.6.1.4.1.13576.10.1.50.8.1.1 -- 1.3.6.1.4.1.13576.10.1.50.8.1.1 wioModuleNumber OBJECT-TYPE SYNTAX INTEGER (1..249) ACCESS read-only STATUS mandatory DESCRIPTION "Number of module slot" ::= { wioModuleEntry 1 } -- 1.3.6.1.4.1.13576.10.1.50.8.1.2 -- 1.3.6.1.4.1.13576.10.1.50.8.1.2 wioModuleName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "Name of module" ::= { wioModuleEntry 2 } -- 1.3.6.1.4.1.13576.10.1.50.8.1.3 -- 1.3.6.1.4.1.13576.10.1.50.8.1.3 wioModuleType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Type of module" ::= { wioModuleEntry 3 } -- 1.3.6.1.4.1.13576.10.1.50.8.1.4 -- 1.3.6.1.4.1.13576.10.1.50.8.1.4 wioModuleCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Count of module" ::= { wioModuleEntry 4 } -- 1.3.6.1.4.1.13576.10.1.50.8.1.5 -- 1.3.6.1.4.1.13576.10.1.50.8.1.5 wioModuleAlternativeFormat OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Module in alternative format" ::= { wioModuleEntry 5 } -- 1.3.6.1.4.1.13576.10.1.50.8.1.6 -- 1.3.6.1.4.1.13576.10.1.50.8.1.6 wioModuleAnalogOutLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of analog output datas of module (Bit)" ::= { wioModuleEntry 6 } -- 1.3.6.1.4.1.13576.10.1.50.8.1.7 -- 1.3.6.1.4.1.13576.10.1.50.8.1.7 wioModuleAnalogInLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of analog input datas of module (Bit)" ::= { wioModuleEntry 7 } -- 1.3.6.1.4.1.13576.10.1.50.8.1.8 -- 1.3.6.1.4.1.13576.10.1.50.8.1.8 wioModuleDigitalOutLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of digital output datas of module (Bit)" ::= { wioModuleEntry 8 } -- 1.3.6.1.4.1.13576.10.1.50.8.1.9 -- 1.3.6.1.4.1.13576.10.1.50.8.1.9 wioModuleDigitalInLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of digital input datas of module (Bit)" ::= { wioModuleEntry 9 } -- 1.3.6.1.4.1.13576.10.1.100 -- 1.3.6.1.4.1.13576.10.1.100 wioPlcData OBJECT IDENTIFIER ::= { wioCommon 100 } -- 1.3.6.1.4.1.13576.10.1.100.1 -- 1.3.6.1.4.1.13576.10.1.100.1 wioPlcDataTable OBJECT-TYPE SYNTAX SEQUENCE OF WioPlcDataEntry ACCESS not-accessible STATUS mandatory ::= { wioPlcData 1 } -- 1.3.6.1.4.1.13576.10.1.100.1.1 -- 1.3.6.1.4.1.13576.10.1.100.1.1 wioPlcDataEntry OBJECT-TYPE SYNTAX WioPlcDataEntry ACCESS not-accessible STATUS mandatory INDEX { wioPlcDataIndex } ::= { wioPlcDataTable 1 } WioPlcDataEntry ::= SEQUENCE { wioPlcDataIndex INTEGER, wioPlcDataReadArea INTEGER, wioPlcDataWriteArea INTEGER } -- 1.3.6.1.4.1.13576.10.1.100.1.1.1 -- 1.3.6.1.4.1.13576.10.1.100.1.1.1 wioPlcDataIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Number of plc data DWORD" ::= { wioPlcDataEntry 1 } -- 1.3.6.1.4.1.13576.10.1.100.1.1.2 -- 1.3.6.1.4.1.13576.10.1.100.1.1.2 wioPlcDataReadArea OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Readable plc data (DWORD)" ::= { wioPlcDataEntry 2 } -- 1.3.6.1.4.1.13576.10.1.100.1.1.3 -- 1.3.6.1.4.1.13576.10.1.100.1.1.3 wioPlcDataWriteArea OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Write- / Readable plc data (DWORD)" ::= { wioPlcDataEntry 3 } -- -- Trap definitions -- -- Trap definitions -- wioPlcKbusError TRAP-TYPE ENTERPRISE wago VARIABLES { wioTrapKbusError } DESCRIPTION "Trap, if KBus state change to error" ::= 1 wioPlcStart TRAP-TYPE ENTERPRISE wago VARIABLES { wioTrapPlcStart } DESCRIPTION "Trap, if PLC programm start" ::= 2 wioPlcStop TRAP-TYPE ENTERPRISE wago VARIABLES { wioTrapPlcStop } DESCRIPTION "Trap, if PLC programm stop" ::= 3 wioPlcReset TRAP-TYPE ENTERPRISE wago VARIABLES { wioTrapPlcReset } DESCRIPTION "Trap, if PLC programm reset" ::= 4 wioPlcSoftwareWatchdog TRAP-TYPE ENTERPRISE wago VARIABLES { wioTrapPlcSoftwareWatchdog } DESCRIPTION "Trap, if PLC software watchdog is detected" ::= 5 wioPlcDivideByZero TRAP-TYPE ENTERPRISE wago VARIABLES { wioTrapPlcDivideByZero } DESCRIPTION "Trap, if PLC software detect a division by zero" ::= 6 wioPlcOnlineChange TRAP-TYPE ENTERPRISE wago VARIABLES { wioTrapPlcOnlineChange } DESCRIPTION "Trap, if PLC programm change online" ::= 7 wioPlcDownload TRAP-TYPE ENTERPRISE wago VARIABLES { wioTrapPlcDownload } DESCRIPTION "Trap, if PLC new programm is downloading" ::= 8 wioPlcLogin TRAP-TYPE ENTERPRISE wago VARIABLES { wioTrapPlcLogin } DESCRIPTION "Trap, if someone login to PLC" ::= 9 wioPlcLogout TRAP-TYPE ENTERPRISE wago VARIABLES { wioTrapPlcLogout } DESCRIPTION "Trap, if someone logout from PLC" ::= 10 END -- -- WAGO-MIB.my --