-- ********************************************************** -- Copyright 2019-2023 VMware, Inc. All rights reserved. -- ********************************************************** VMWARE-NSX-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF TEXTUAL-CONVENTION, DateAndTime FROM SNMPv2-TC vmwNSXsys FROM VMWARE-ROOT-MIB; vmwNSXsysMIB MODULE-IDENTITY LAST-UPDATED "202304020000Z" ORGANIZATION "VMware, Inc" CONTACT-INFO "VMware, Inc 3401 Hillview Ave Palo Alto, CA 94304 Tel: 1-877-486-9273 or 650-427-5000 Fax: 650-427-5001 Web: http://kb.vmware.com/kb/1013445 " DESCRIPTION "In much the same way that server virtualization programmatically creates, snapshots, deletes, and restores software-based virtual machines (VMs), NSX Data Center network virtualization programmatically creates, deletes, and restores software-based virtual networks. With network virtualization, the functional equivalent of a network hypervisor reproduces the complete set of Layer 2 through Layer 7 networking services (for example, switching, routing, access control, firewalling, QoS) in software. As a result, these services can be programmatically assembled in any arbitrary combination, to produce unique, isolated virtual networks in a matter of seconds. For more information about NSX Data Center, please visit: https://docs.vmware.com/en/VMware-NSX-T-Data-Center/ " REVISION "202304020000Z" DESCRIPTION "This revision adds 48 new notifications for NSX Data Center 4.1.0" REVISION "202206210000Z" DESCRIPTION "This revision adds 106 new notifications for NSX Data Center 4.0.0" REVISION "202206160000Z" DESCRIPTION "This revision adds 6 new notifications for NSX Data Center 3.2.1" REVISION "202202140000Z" DESCRIPTION "This revision adds 174 new notifications for NSX Data Center 3.2.0" REVISION "202108060000Z" DESCRIPTION "This revision adds 18 new notifications for NSX Data Center 3.1.3" REVISION "202104220000Z" DESCRIPTION "This revision adds 12 new notifications for NSX Data Center 3.1.2" REVISION "202103250000Z" DESCRIPTION "This revision adds 2 new notifications for NSX Data Center 3.0.3" REVISION "202101300000Z" DESCRIPTION "This revision adds 2 new notifications for NSX Data Center 3.1.1" REVISION "202010300000Z" DESCRIPTION "This revision adds 56 new notifications for NSX Data Center 3.1.0" REVISION "202009220000Z" DESCRIPTION "This revision adds 10 new notifications for NSX Data Center 3.0.2" REVISION "202006290000Z" DESCRIPTION "This revision adds 12 new notifications for NSX Data Center 3.0.1" REVISION "202003240000Z" DESCRIPTION "Initial revision of NSX Data Center SNMP event notifications." ::= { vmwNSXsys 1 } -- ********************************************************** -- Top-level MIB groups -- ********************************************************** vmwNsxTDataCenterNotifications OBJECT-IDENTITY STATUS current DESCRIPTION "All event notifications from NSX Data Center fall under this oid." ::= { vmwNSXsysMIB 0 } vmwNsxTDataCenterData OBJECT-IDENTITY STATUS current DESCRIPTION "All variables that are sent in NSX Data Center event notifications fall under this oid." ::= { vmwNSXsysMIB 1 } -- ********************************************************** -- Type definitions -- ********************************************************** VmwNsxTDataCenterFeatureIdType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The NSX Data Center feature ID associated with the event. For example, this value identifies the feature is managerHealth, edgeHealth, loadBalancer, etc." SYNTAX INTEGER { managerHealth(1), edgeHealth(2), certificates(3), passwordManagement(4), licenses(5), intelligenceHealth(6), infrastructureCommunication(7), intelligenceCommunication(9), cniHealth(10), ncpHealth(11), nodeAgentsHealth(12), endpointProtection(13), serviceInsertion(14), vpn(15), alarmManagement(16), loadBalancer(17), transportNodeHealth(18), infrastructureService(19), dhcp(20), highAvailability(21), capacity(22), auditLogHealth(24), routing(28), dns(30), distributedFirewall(31), federation(32), distributedIdsIps(33), communication(35), identityFirewall(36), ipam(38), gatewayFirewall(39), clustering(40), nsxApplicationPlatformCommunication(41), mtuCheck(42), nsxApplicationPlatformHealth(43), edge(45), nat(46), physicalServer(47), malwarePreventionHealth(48), edgeCluster(49), vmcApp(50), tepHealth(51), policyConstraint(53), groups(54), securityCompliance(56), nsxaasHealth(58) } VmwNsxTDataCenterEventTypeType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The name of the NSX Data Center event. The complete set of events are reported by the NSX API GET /api/v1/events." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterSeverityType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The severity of the NSX Data Center event. Currently only the critical(2), error(3), warning(4) and informational(6) levels are used, but the other levels may be used in future releases." SYNTAX INTEGER { emergency(0), alert(1), critical(2), error(3), warning(4), notice(5), informational(6), debug(7) } VmwNsxTDataCenterNodeIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The node ID from where a NSX Data Center event was emitted. A node ID can be for a cluster node as reported by the NSX API GET /api/v1/cluster. Or a node ID can be for a transport node as reported by the NSX API GET /api/v1/transport-nodes." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterNodeTypeType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The type of node from where a NSX Data Center event was emitted." SYNTAX INTEGER { manager(0), edge(1), esx(2), kvm(3), publiccloudgateway(4), intelligence(5), autonomousedge(6), globalmanager(7) } VmwNsxTDataCenterEntityIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The ID of a NSX Data Center entity an event pertains to. The event description field provides additional details of the entity. For example the ID can be for a specific Load Balancer rule as reported by the NSX API GET /api/v1/loadbalancer/rules or a specific certificate as reported by the NSX API GET /api/v1/trust-management/certificates." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterSystemResourceUsageType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The CPU, memory, or disk usage percentage of an NSX appliance. The value is an integer between 0 and 100." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterDiskPartitionNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The name of a disk partition in an NSX appliance. For example, the name for the /tmp partition is '/tmp'." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterLicenseEditionTypeType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The edition type of an NSX license. For example, the type for an NSX evaluation license is 'NSX Data Center Evaluation'." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterApplianceAddressType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The NSX appliance's IP address. The value is an IPv4 address." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterCurrentGatewayStateType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The current gateway state. The value could be 0, 1 or 2 where 0 is down, 1 is standby and 2 is active" SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterCurrentServiceStateType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The current service state. The value could be start/stop/restart/crashed." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterDatapathResourceUsageType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The CPU, memory, or disk usage percentage of the datapath on a NSX appliance. The value is an integer between 0 and 100." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterDHCPPoolUsageType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The usage of a DHCP pool. The value is an integer between 0 and 100." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterEdgeServiceNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The name of the service running on the Edge node." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterFailureReasonType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The detailed reason of any module failure like BGP down, IKE down, etc." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterPreviousGatewayStateType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The previous gateway state. The value could be 0, 1 or 2 where 0 is down, 1 is standby and 2 is active" SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterPreviousServiceStateType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The previous service state. The value could be start/stop/restart/crashed." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterSystemUsageThresholdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The configured threshold value for the CPU, memory, or disk usage percentage of an NSX appliance. The value is an integer between 0 and 100." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterUsernameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The name of a user in an NSX appliance." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterDHCPServerIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The UUID of a DHCP server." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterServiceNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The name of the service running in an NSX appliance." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterIntelligenceNodeIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The node ID of an NSX Intelligence node." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterHostnameOrIPAddressWithPortType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Hostname or ip address with port of logging server." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterEventIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The event identifier." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterActiveGlobalManagerType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The identifier for the active Global Manager node." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterActiveGlobalManagersType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "A comma delimited list of identifiers for the active Global Manager nodes." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterSessionDownReasonType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Down reason of the IPsec VPN session." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterManagerNodeNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The display name of a NSX Manager node." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterTransportNodeAddressType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The IP address of a NSX Transport node." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterTransportNodeNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The display name of a NSX Transport node." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterCentralControlPlaneIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The UUID of a NSX centrol control plane." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterTunnelDownReasonType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Down reason of the IPsec VPN tunnel." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterHeapTypeType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Heap type information for DFW memory usage like vsip-attr, vsip-flow, vsip-fqdni, etc." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterMempoolNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Name of a memory pool." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterPasswordExpirationDaysType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The number of days left before expiration of the password of an NSX appliance user. The value is an integer greater than 0." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterBGPNeighborIPType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "IP address of BGP Neighbor. This could be either IPv4 or IPv6 address." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterLDAPServerType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The name or IP address of a LDAP server." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterPeerAddressType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "IP address of BFD peer." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterMaxIDSEventsAllowedType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The maximum number of IDS events that are allowed in the system, anything beyond this would be purged at regular intervals." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterStaticAddressType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "A Static IP address." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterDuplicateIPAddressType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Duplicate IP address." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterCapacityDisplayNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Display name of type on capacity dashboard." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterCapacityUsageCountType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Current usage count of capacity usage type." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterEdgeNICNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The name of the NIC whose link is down or which faced tx/rx ring buffer overflow." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterRxRingBufferOverflowPercentageType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The NIC's receive descriptor ring buffer on a NSX Edge or Gateway node has no space left to accomodate new incoming packets and there is a significant drop due to it. The value is a float between 0 to 100 describing the overflow percentage due to the packet drops." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterTxRingBufferOverflowPercentageType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The NIC's transmit descriptor ring buffer on a NSX Edge or Gateway node has no space left to accomodate new outgoing packets and there is a significant drop due to it. The value is a float between 0 to 100 describing the overflow percentage due to the packet drops." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterSrIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Service Router UUID." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterIDSEventsCountType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Count of the IDS events in the system currently." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterRemoteSiteNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Name of a remote site in federation. For more information on remote sites and an overview of the federation feature, refer to: https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-D5B6DC79-6733-44A7-8072-50221CF2122A.html" SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterBGPSourceIPType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Source IP address of BGP session. This could be either an IPv4 address in dotted-decimal format or an IPv6 address in IPv6 address format." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterRemoteSiteIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The identifier for a remote site." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterSiteIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The identifier for a local site." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterSiteNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Name of a local site in federation. For more information on local sites and an overview of the federation feature, refer to: https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-D5B6DC79-6733-44A7-8072-50221CF2122A.html" SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterLrIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Logical Router UUID." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterRxMissesType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The number of packets missed while receiving due to rx ring buffer being full." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterRxProcessedType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The number of successful incoming packets while polling for rx buffer full event." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterTxMissesType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The number of packets missed while transmitting due to tx ring buffer being full." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterTxProcessedType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The number of successful outgoing packets while polling for tx buffer full event." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterLrportIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Logical Router Port UUID." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterServiceIPType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The IP configured for the service running in an NSX appliance in dotted-decimal format." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterRemoteManagerNodeIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The remote Manager node UUID." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterDirectoryDomainType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The name of a directory domain." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterTimeoutInMinutesType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Timeout value in minutes." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterMaxCapacityThresholdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Maximum threshold defined for capacity usage type." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterMinCapacityThresholdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Minimum threshold defined for capacity usage type." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterMaxSupportedCapacityCountType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Maximum supported count for capacity usage type." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterLatencySourceType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The source of reported latency." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterLatencyThresholdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Threshold value of reported IO latency." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterLatencyValueType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Value of reported IO latency." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterApplianceFQDNType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The NSX appliance's fully qualified domain name." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterRemoteApplianceAddressType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The remote NSX appliance's IP address. The value is an IPv4 address." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterManagerNodeIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The Manager node UUID." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterDisplayedLicenseKeyType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The last 5 characters of the license key of an NSX license." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterEdgeThreadNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The name of the Edge node thread." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterIntentPathType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The policy intent path." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterFirewallHalfopenFlowUsageType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Current firewall TCP half-open connection usage percentage of max supported value. The value is an integer between 0 and 100." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterFirewallICMPFlowUsageType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Current firewall ICMP connection usage percentage of max supported value. The value is an integer between 0 and 100." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterServiceDownReasonType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Reason service is down." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterFirewallUDPFlowUsageType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Current firewall UDP connection usage percentage of max supported value. The value is an integer between 0 and 100." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterFirewallIPFlowUsageType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Current firewall IP connection usage percentage of max supported value. The value is an integer between 0 and 100." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterDNSIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The DNS forwarder identifier." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterDNSUpstreamIPType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "IP address of one DNS forwarder upstream server." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterCABundleAgeThresholdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The age threshold in days for the CA bundle." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterAPICollectionPathType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The API path of the collection containing entity_id." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterEdgeNodeSettingMismatchReasonType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String containing Policy/MP intent of Edge transport node settings that differs from corresponding Edge transport node settings on Edge NSX CLI." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReasonType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String containing Policy/MP intent of Edge transport node vSphere deployment configuration that differs from corresponding Edge transport node configuration on vSphere." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterFirewallSNATPortsUsageType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Current firewall SNAT ports usage percentage of max supported value. The value is an integer between 0 and 100." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterEdgevSphereLocationMismatchReasonType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String containing Policy/MP intent of vSphere deployment configuration that differs from corresponding Edge transport node configuration on vSphere when vMotion happens for Edge node." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReasonType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String containing Policy/MP intent of Edge transport node settings and vSphere deployment configuration that differs from corresponding Edge transport node settings on Edge NSX CLI and Edge transport node configuration on vSphere." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterSNATIPAddressType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The SNAT IP address which ran out of port threshold." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterNappClusterIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The cluster ID of the NSX Application Platform cluster." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterNappMessagingLAGThresholdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The configured threshold value for the number of pending messages in an NSX Application Platform messaging topic." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterNappNodeIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The node ID of an NSX Application Platform node." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterNappServiceNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The service name of an NSX Application Platform service." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterFlowIdentifierType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "A flow identifier indicating the direction of flow of data which is one of following. - GM_2_LM - LM_2_GM_NOTIFICATION - LM_2_GM_ONBOARD_CONFIG" SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterSyncIssueReasonType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "A reason for data synchronization issue." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterQueueNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The name of the queue used to synchronize data between two sites." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterQueueSizeType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The occupancy size of queue used to synchronize data between two sites." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterQueueSizeThresholdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Maximum threshold value of reported queue size." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterGroupTypeType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The group type of a GMLE cluster." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterManagerNodeIDSType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "A comma delimited list of identifiers for the Manager nodes." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterServiceRouterIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The ID of a service-router that is part of a tier0 or tier1 gateway spanning one or more edges" SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterTransportNodeIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The Transport node UUID." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterFromGMPathType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Policy path of the Global Manager." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterToGMPathType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Policy path of the Global Manager." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterNICThroughputType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The NIC throughput, as a percentage. The value is an integer between 0 and 100." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterNICThroughputThresholdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The NIC throughput threshold, as a percentage. The value is an integer between 0 and 100." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterEdgeCryptoDrvNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Name of the edge crypto driver." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterNappNodeNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The node name of an NSX Application Platform node." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterNewVMMorefIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String containing Edge VM moref details corresponding to Policy/MP intent vSphere deployment configuration." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterPolicyEdgeVMNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String containing Edge VM name corresponding to Policy/MP intent vSphere deployment configuration." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterVMMorefIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String containing Edge VM moref details corresponding to Policy/MP intent vSphere deployment configuration." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterDPUIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Data processing unit identifier." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterEdgeNodeType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String representing the Edge node UUID." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterPrefixesCountMaxType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Maximum value of prefix count of BGP neighbor." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterPrefixesCountThresholdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Threshold Value of prefix count of BGP neighbor." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterRouteLimitMaximumType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String representing maximum limit for routes." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterRouteLimitThresholdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String representing threshold limit for routes." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterSubsequentAddressFamilyType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String representing subsequent address family (Unicast or Multicast)." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCentervCenterClusterIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Cluster identifier in the Virtual Center." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterMpsServiceNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The service name of an NSX Malware Prevention service." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterMemberIndexIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String representing member index ID." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterEdgeClusterIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String representing the edge cluster ID." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterCoreDumpCountType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The number of core dump file generated in system." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterNodeDisplayOrHostNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Display name or Host name of NSX node." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterNSXEdgeTNNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The display name of a NSX Edge Transport node." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterNSXESXTNNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The display name of a NSX Host Transport node." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterCollectorIPType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "External OPS collector IP address for OPS features." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterDvsAliasType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "DVS name to indicate given DVS." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterStackAliasType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Stack name specified for given vmknic." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterVerticalNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Name of OPS vertical on DPU." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterEdgeClusterHighestHwVersionType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String containing highest hardware version of Edge Transport Node in edge cluster." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterEdgeTNHwVersionType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String containing hardware version of Edge Transport Node." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterEdgeClusterNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String containing Edge cluster display name." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterHaStateType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The current high-availability state. The value could be active/standby/down." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterHaState2Type ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The current high-availability state. The value could be active/standby/down." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterTransportNodeId2Type ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The Transport node UUID." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterDvsNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The ESXi DVS name." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterVtepFaultReasonType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The VTEP fault reason." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterVtepNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The ESXi VTEP name." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterMetricsTargetAddressType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "IP address of specified target metrics being delivered to." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterMetricsTargetAliasType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Alias of specified target metrics being delivered to." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterMetricsTargetPortType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Listen port of specified target metrics being delivered to." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterIPv4AddressType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Name of IPv4 address in dual stack." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterIPv6AddressType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Name of IPv6 address in dual stack." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterConstraintLimitType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Value of constraint limit." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterConstraintTypeType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Type of constraint resource." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterCurrentCountType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Current count of object." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterGroupIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The group UUID." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterGroupMaxNumberLimitType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Maximum number of group elements supported." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterGroupSizeType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Total number of group elements." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterIPCountType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Number of IP sets inside one group." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterLrpCountType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Number of logical router port inside one group." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterLspCountType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Number of logical switch port inside one group." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterMacCountType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Number of MAC sets inside one group." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterSidCountType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Number of security IDs inside one group." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterTNCountType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Number of Transport Nodes inside one group." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterVifCountType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Number of VIFs inside one group." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterVMCountType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Number of VMs inside one group." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterCoreIdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String to identify the core on which event is triggered." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterFlowCacheThresholdType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String to identify the flow cache threshold." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterNSXaaSServiceNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "The name of the service running in NSXaaS." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterProtocolNameType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "String containing network protocol." SYNTAX OCTET STRING (SIZE (0..256)) VmwNsxTDataCenterConstraintTypePathType ::= TEXTUAL-CONVENTION DISPLAY-HINT "256a" STATUS current DESCRIPTION "Path prefix of constraint resource." SYNTAX OCTET STRING (SIZE (0..256)) vmwNsxTDataCenterTimestamp OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The timestamp when the NSX Data Center event occurred." ::= { vmwNsxTDataCenterData 1 } vmwNsxTDataCenterFeatureName OBJECT-TYPE SYNTAX VmwNsxTDataCenterFeatureIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The NSX Data Center feature ID associated with the event." ::= { vmwNsxTDataCenterData 2 } vmwNsxTDataCenterEventType OBJECT-TYPE SYNTAX VmwNsxTDataCenterEventTypeType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The name of the NSX Data Center event." ::= { vmwNsxTDataCenterData 3 } vmwNsxTDataCenterEventSeverity OBJECT-TYPE SYNTAX VmwNsxTDataCenterSeverityType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The severity of the NSX Data Center event." ::= { vmwNsxTDataCenterData 4 } vmwNsxTDataCenterNodeId OBJECT-TYPE SYNTAX VmwNsxTDataCenterNodeIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The node ID from where a NSX Data Center event was emitted." ::= { vmwNsxTDataCenterData 5 } vmwNsxTDataCenterNodeType OBJECT-TYPE SYNTAX VmwNsxTDataCenterNodeTypeType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The type of node from where a NSX Data Center event was emitted." ::= { vmwNsxTDataCenterData 6 } vmwNsxTDataCenterEntityId OBJECT-TYPE SYNTAX VmwNsxTDataCenterEntityIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The ID of a NSX Data Center entity an event pertains to. The event description field provides additional details of the entity. For example the ID can be for a specific Load Balancer rule as reported by the NSX API GET /api/v1/loadbalancer/rules or a specific certificate as reported by the NSX API GET /api/v1/trust-management/certificates." ::= { vmwNsxTDataCenterData 21 } vmwNsxTDataCenterSystemResourceUsage OBJECT-TYPE SYNTAX VmwNsxTDataCenterSystemResourceUsageType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The CPU, memory, or disk usage percentage of an NSX appliance. The value is an integer between 0 and 100." ::= { vmwNsxTDataCenterData 22 } vmwNsxTDataCenterDiskPartitionName OBJECT-TYPE SYNTAX VmwNsxTDataCenterDiskPartitionNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The name of a disk partition in an NSX appliance. For example, the name for the /tmp partition is '/tmp'." ::= { vmwNsxTDataCenterData 23 } vmwNsxTDataCenterLicenseEditionType OBJECT-TYPE SYNTAX VmwNsxTDataCenterLicenseEditionTypeType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The edition type of an NSX license. For example, the type for an NSX evaluation license is 'NSX Data Center Evaluation'." ::= { vmwNsxTDataCenterData 24 } vmwNsxTDataCenterApplianceAddress OBJECT-TYPE SYNTAX VmwNsxTDataCenterApplianceAddressType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The NSX appliance's IP address. The value is an IPv4 address." ::= { vmwNsxTDataCenterData 25 } vmwNsxTDataCenterCurrentGatewayState OBJECT-TYPE SYNTAX VmwNsxTDataCenterCurrentGatewayStateType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The current gateway state. The value could be 0, 1 or 2 where 0 is down, 1 is standby and 2 is active" ::= { vmwNsxTDataCenterData 26 } vmwNsxTDataCenterCurrentServiceState OBJECT-TYPE SYNTAX VmwNsxTDataCenterCurrentServiceStateType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The current service state. The value could be start/stop/restart/crashed." ::= { vmwNsxTDataCenterData 27 } vmwNsxTDataCenterDatapathResourceUsage OBJECT-TYPE SYNTAX VmwNsxTDataCenterDatapathResourceUsageType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The CPU, memory, or disk usage percentage of the datapath on a NSX appliance. The value is an integer between 0 and 100." ::= { vmwNsxTDataCenterData 28 } vmwNsxTDataCenterDHCPPoolUsage OBJECT-TYPE SYNTAX VmwNsxTDataCenterDHCPPoolUsageType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The usage of a DHCP pool. The value is an integer between 0 and 100." ::= { vmwNsxTDataCenterData 29 } vmwNsxTDataCenterEdgeServiceName OBJECT-TYPE SYNTAX VmwNsxTDataCenterEdgeServiceNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The name of the service running on the Edge node." ::= { vmwNsxTDataCenterData 30 } vmwNsxTDataCenterFailureReason OBJECT-TYPE SYNTAX VmwNsxTDataCenterFailureReasonType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The detailed reason of any module failure like BGP down, IKE down, etc." ::= { vmwNsxTDataCenterData 31 } vmwNsxTDataCenterPreviousGatewayState OBJECT-TYPE SYNTAX VmwNsxTDataCenterPreviousGatewayStateType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The previous gateway state. The value could be 0, 1 or 2 where 0 is down, 1 is standby and 2 is active" ::= { vmwNsxTDataCenterData 32 } vmwNsxTDataCenterPreviousServiceState OBJECT-TYPE SYNTAX VmwNsxTDataCenterPreviousServiceStateType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The previous service state. The value could be start/stop/restart/crashed." ::= { vmwNsxTDataCenterData 33 } vmwNsxTDataCenterSystemUsageThreshold OBJECT-TYPE SYNTAX VmwNsxTDataCenterSystemUsageThresholdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The configured threshold value for the CPU, memory, or disk usage percentage of an NSX appliance. The value is an integer between 0 and 100." ::= { vmwNsxTDataCenterData 34 } vmwNsxTDataCenterUsername OBJECT-TYPE SYNTAX VmwNsxTDataCenterUsernameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The name of a user in an NSX appliance." ::= { vmwNsxTDataCenterData 35 } vmwNsxTDataCenterDHCPServerId OBJECT-TYPE SYNTAX VmwNsxTDataCenterDHCPServerIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The UUID of a DHCP server." ::= { vmwNsxTDataCenterData 36 } vmwNsxTDataCenterServiceName OBJECT-TYPE SYNTAX VmwNsxTDataCenterServiceNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The name of the service running in an NSX appliance." ::= { vmwNsxTDataCenterData 37 } vmwNsxTDataCenterIntelligenceNodeId OBJECT-TYPE SYNTAX VmwNsxTDataCenterIntelligenceNodeIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The node ID of an NSX Intelligence node." ::= { vmwNsxTDataCenterData 38 } vmwNsxTDataCenterHostnameOrIPAddressWithPort OBJECT-TYPE SYNTAX VmwNsxTDataCenterHostnameOrIPAddressWithPortType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 39 } vmwNsxTDataCenterEventId OBJECT-TYPE SYNTAX VmwNsxTDataCenterEventIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The event identifier." ::= { vmwNsxTDataCenterData 40 } vmwNsxTDataCenterActiveGlobalManager OBJECT-TYPE SYNTAX VmwNsxTDataCenterActiveGlobalManagerType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 41 } vmwNsxTDataCenterActiveGlobalManagers OBJECT-TYPE SYNTAX VmwNsxTDataCenterActiveGlobalManagersType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 42 } vmwNsxTDataCenterSessionDownReason OBJECT-TYPE SYNTAX VmwNsxTDataCenterSessionDownReasonType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Down reason of the IPsec VPN session." ::= { vmwNsxTDataCenterData 43 } vmwNsxTDataCenterManagerNodeName OBJECT-TYPE SYNTAX VmwNsxTDataCenterManagerNodeNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 44 } vmwNsxTDataCenterTransportNodeAddress OBJECT-TYPE SYNTAX VmwNsxTDataCenterTransportNodeAddressType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 45 } vmwNsxTDataCenterTransportNodeName OBJECT-TYPE SYNTAX VmwNsxTDataCenterTransportNodeNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 46 } vmwNsxTDataCenterCentralControlPlaneId OBJECT-TYPE SYNTAX VmwNsxTDataCenterCentralControlPlaneIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 47 } vmwNsxTDataCenterTunnelDownReason OBJECT-TYPE SYNTAX VmwNsxTDataCenterTunnelDownReasonType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Down reason of the IPsec VPN tunnel." ::= { vmwNsxTDataCenterData 48 } vmwNsxTDataCenterHeapType OBJECT-TYPE SYNTAX VmwNsxTDataCenterHeapTypeType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Heap type information for DFW memory usage like vsip-attr, vsip-flow, vsip-fqdni, etc." ::= { vmwNsxTDataCenterData 49 } vmwNsxTDataCenterMempoolName OBJECT-TYPE SYNTAX VmwNsxTDataCenterMempoolNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Name of a memory pool." ::= { vmwNsxTDataCenterData 50 } vmwNsxTDataCenterPasswordExpirationDays OBJECT-TYPE SYNTAX VmwNsxTDataCenterPasswordExpirationDaysType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The number of days left before expiration of the password of an NSX appliance user. The value is an integer greater than 0." ::= { vmwNsxTDataCenterData 51 } vmwNsxTDataCenterBGPNeighborIP OBJECT-TYPE SYNTAX VmwNsxTDataCenterBGPNeighborIPType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "IP address of BGP Neighbor. This could be either IPv4 or IPv6 address." ::= { vmwNsxTDataCenterData 52 } vmwNsxTDataCenterLDAPServer OBJECT-TYPE SYNTAX VmwNsxTDataCenterLDAPServerType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 53 } vmwNsxTDataCenterPeerAddress OBJECT-TYPE SYNTAX VmwNsxTDataCenterPeerAddressType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "IP address of BFD peer." ::= { vmwNsxTDataCenterData 54 } vmwNsxTDataCenterMaxIDSEventsAllowed OBJECT-TYPE SYNTAX VmwNsxTDataCenterMaxIDSEventsAllowedType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 55 } vmwNsxTDataCenterStaticAddress OBJECT-TYPE SYNTAX VmwNsxTDataCenterStaticAddressType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "A Static IP address." ::= { vmwNsxTDataCenterData 56 } vmwNsxTDataCenterDuplicateIPAddress OBJECT-TYPE SYNTAX VmwNsxTDataCenterDuplicateIPAddressType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Duplicate IP address." ::= { vmwNsxTDataCenterData 57 } vmwNsxTDataCenterCapacityDisplayName OBJECT-TYPE SYNTAX VmwNsxTDataCenterCapacityDisplayNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 58 } vmwNsxTDataCenterCapacityUsageCount OBJECT-TYPE SYNTAX VmwNsxTDataCenterCapacityUsageCountType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 59 } vmwNsxTDataCenterEdgeNICName OBJECT-TYPE SYNTAX VmwNsxTDataCenterEdgeNICNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The name of the NIC whose link is down or which faced tx/rx ring buffer overflow." ::= { vmwNsxTDataCenterData 60 } vmwNsxTDataCenterRxRingBufferOverflowPercentage OBJECT-TYPE SYNTAX VmwNsxTDataCenterRxRingBufferOverflowPercentageType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The NIC's receive descriptor ring buffer on a NSX Edge or Gateway node has no space left to accomodate new incoming packets and there is a significant drop due to it. The value is a float between 0 to 100 describing the overflow percentage due to the packet drops." ::= { vmwNsxTDataCenterData 61 } vmwNsxTDataCenterTxRingBufferOverflowPercentage OBJECT-TYPE SYNTAX VmwNsxTDataCenterTxRingBufferOverflowPercentageType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The NIC's transmit descriptor ring buffer on a NSX Edge or Gateway node has no space left to accomodate new outgoing packets and there is a significant drop due to it. The value is a float between 0 to 100 describing the overflow percentage due to the packet drops." ::= { vmwNsxTDataCenterData 62 } vmwNsxTDataCenterSrId OBJECT-TYPE SYNTAX VmwNsxTDataCenterSrIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Service Router UUID." ::= { vmwNsxTDataCenterData 63 } vmwNsxTDataCenterIDSEventsCount OBJECT-TYPE SYNTAX VmwNsxTDataCenterIDSEventsCountType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 64 } vmwNsxTDataCenterRemoteSiteName OBJECT-TYPE SYNTAX VmwNsxTDataCenterRemoteSiteNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 65 } vmwNsxTDataCenterBGPSourceIP OBJECT-TYPE SYNTAX VmwNsxTDataCenterBGPSourceIPType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 66 } vmwNsxTDataCenterRemoteSiteId OBJECT-TYPE SYNTAX VmwNsxTDataCenterRemoteSiteIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 67 } vmwNsxTDataCenterSiteId OBJECT-TYPE SYNTAX VmwNsxTDataCenterSiteIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 68 } vmwNsxTDataCenterSiteName OBJECT-TYPE SYNTAX VmwNsxTDataCenterSiteNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 69 } vmwNsxTDataCenterLrId OBJECT-TYPE SYNTAX VmwNsxTDataCenterLrIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 70 } vmwNsxTDataCenterRxMisses OBJECT-TYPE SYNTAX VmwNsxTDataCenterRxMissesType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 71 } vmwNsxTDataCenterRxProcessed OBJECT-TYPE SYNTAX VmwNsxTDataCenterRxProcessedType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 72 } vmwNsxTDataCenterTxMisses OBJECT-TYPE SYNTAX VmwNsxTDataCenterTxMissesType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 73 } vmwNsxTDataCenterTxProcessed OBJECT-TYPE SYNTAX VmwNsxTDataCenterTxProcessedType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 74 } vmwNsxTDataCenterLrportId OBJECT-TYPE SYNTAX VmwNsxTDataCenterLrportIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Logical Router Port UUID." ::= { vmwNsxTDataCenterData 75 } vmwNsxTDataCenterServiceIP OBJECT-TYPE SYNTAX VmwNsxTDataCenterServiceIPType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The Ip configured for the service running in an NSX appliance." ::= { vmwNsxTDataCenterData 77 } vmwNsxTDataCenterRemoteManagerNodeId OBJECT-TYPE SYNTAX VmwNsxTDataCenterRemoteManagerNodeIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 80 } vmwNsxTDataCenterDirectoryDomain OBJECT-TYPE SYNTAX VmwNsxTDataCenterDirectoryDomainType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 81 } vmwNsxTDataCenterTimeoutInMinutes OBJECT-TYPE SYNTAX VmwNsxTDataCenterTimeoutInMinutesType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 82 } vmwNsxTDataCenterMaxCapacityThreshold OBJECT-TYPE SYNTAX VmwNsxTDataCenterMaxCapacityThresholdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 83 } vmwNsxTDataCenterMinCapacityThreshold OBJECT-TYPE SYNTAX VmwNsxTDataCenterMinCapacityThresholdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 84 } vmwNsxTDataCenterMaxSupportedCapacityCount OBJECT-TYPE SYNTAX VmwNsxTDataCenterMaxSupportedCapacityCountType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 85 } vmwNsxTDataCenterLatencySource OBJECT-TYPE SYNTAX VmwNsxTDataCenterLatencySourceType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 86 } vmwNsxTDataCenterLatencyThreshold OBJECT-TYPE SYNTAX VmwNsxTDataCenterLatencyThresholdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 87 } vmwNsxTDataCenterLatencyValue OBJECT-TYPE SYNTAX VmwNsxTDataCenterLatencyValueType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 88 } vmwNsxTDataCenterApplianceFQDN OBJECT-TYPE SYNTAX VmwNsxTDataCenterApplianceFQDNType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 89 } vmwNsxTDataCenterRemoteApplianceAddress OBJECT-TYPE SYNTAX VmwNsxTDataCenterRemoteApplianceAddressType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 90 } vmwNsxTDataCenterManagerNodeId OBJECT-TYPE SYNTAX VmwNsxTDataCenterManagerNodeIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 91 } vmwNsxTDataCenterDisplayedLicenseKey OBJECT-TYPE SYNTAX VmwNsxTDataCenterDisplayedLicenseKeyType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 92 } vmwNsxTDataCenterEdgeThreadName OBJECT-TYPE SYNTAX VmwNsxTDataCenterEdgeThreadNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 93 } vmwNsxTDataCenterIntentPath OBJECT-TYPE SYNTAX VmwNsxTDataCenterIntentPathType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 94 } vmwNsxTDataCenterFirewallHalfopenFlowUsage OBJECT-TYPE SYNTAX VmwNsxTDataCenterFirewallHalfopenFlowUsageType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Firewall TCP half-open connection usage." ::= { vmwNsxTDataCenterData 95 } vmwNsxTDataCenterFirewallICMPFlowUsage OBJECT-TYPE SYNTAX VmwNsxTDataCenterFirewallICMPFlowUsageType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Firewall ICMP connection usage." ::= { vmwNsxTDataCenterData 96 } vmwNsxTDataCenterServiceDownReason OBJECT-TYPE SYNTAX VmwNsxTDataCenterServiceDownReasonType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 97 } vmwNsxTDataCenterFirewallUDPFlowUsage OBJECT-TYPE SYNTAX VmwNsxTDataCenterFirewallUDPFlowUsageType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Firewall UDP connection usage." ::= { vmwNsxTDataCenterData 98 } vmwNsxTDataCenterFirewallIPFlowUsage OBJECT-TYPE SYNTAX VmwNsxTDataCenterFirewallIPFlowUsageType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Firewall IP connection usage." ::= { vmwNsxTDataCenterData 99 } vmwNsxTDataCenterDNSId OBJECT-TYPE SYNTAX VmwNsxTDataCenterDNSIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "DNS forwarder identifier." ::= { vmwNsxTDataCenterData 100 } vmwNsxTDataCenterDNSUpstreamIP OBJECT-TYPE SYNTAX VmwNsxTDataCenterDNSUpstreamIPType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "DNS forwarder upstream server IP address." ::= { vmwNsxTDataCenterData 101 } vmwNsxTDataCenterCABundleAgeThreshold OBJECT-TYPE SYNTAX VmwNsxTDataCenterCABundleAgeThresholdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 121 } vmwNsxTDataCenterAPICollectionPath OBJECT-TYPE SYNTAX VmwNsxTDataCenterAPICollectionPathType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 122 } vmwNsxTDataCenterEdgeNodeSettingMismatchReason OBJECT-TYPE SYNTAX VmwNsxTDataCenterEdgeNodeSettingMismatchReasonType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 123 } vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason OBJECT-TYPE SYNTAX VmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReasonType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 124 } vmwNsxTDataCenterFirewallSNATPortsUsage OBJECT-TYPE SYNTAX VmwNsxTDataCenterFirewallSNATPortsUsageType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 125 } vmwNsxTDataCenterEdgevSphereLocationMismatchReason OBJECT-TYPE SYNTAX VmwNsxTDataCenterEdgevSphereLocationMismatchReasonType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 126 } vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason OBJECT-TYPE SYNTAX VmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReasonType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 127 } vmwNsxTDataCenterSNATIPAddress OBJECT-TYPE SYNTAX VmwNsxTDataCenterSNATIPAddressType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 128 } vmwNsxTDataCenterNappClusterId OBJECT-TYPE SYNTAX VmwNsxTDataCenterNappClusterIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 129 } vmwNsxTDataCenterNappMessagingLAGThreshold OBJECT-TYPE SYNTAX VmwNsxTDataCenterNappMessagingLAGThresholdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 130 } vmwNsxTDataCenterNappNodeId OBJECT-TYPE SYNTAX VmwNsxTDataCenterNappNodeIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 131 } vmwNsxTDataCenterNappServiceName OBJECT-TYPE SYNTAX VmwNsxTDataCenterNappServiceNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 132 } vmwNsxTDataCenterFlowIdentifier OBJECT-TYPE SYNTAX VmwNsxTDataCenterFlowIdentifierType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 133 } vmwNsxTDataCenterSyncIssueReason OBJECT-TYPE SYNTAX VmwNsxTDataCenterSyncIssueReasonType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 134 } vmwNsxTDataCenterQueueName OBJECT-TYPE SYNTAX VmwNsxTDataCenterQueueNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 135 } vmwNsxTDataCenterQueueSize OBJECT-TYPE SYNTAX VmwNsxTDataCenterQueueSizeType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 136 } vmwNsxTDataCenterQueueSizeThreshold OBJECT-TYPE SYNTAX VmwNsxTDataCenterQueueSizeThresholdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 137 } vmwNsxTDataCenterGroupType OBJECT-TYPE SYNTAX VmwNsxTDataCenterGroupTypeType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 138 } vmwNsxTDataCenterManagerNodeIDS OBJECT-TYPE SYNTAX VmwNsxTDataCenterManagerNodeIDSType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 139 } vmwNsxTDataCenterServiceRouterId OBJECT-TYPE SYNTAX VmwNsxTDataCenterServiceRouterIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 140 } vmwNsxTDataCenterTransportNodeId OBJECT-TYPE SYNTAX VmwNsxTDataCenterTransportNodeIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 141 } vmwNsxTDataCenterFromGMPath OBJECT-TYPE SYNTAX VmwNsxTDataCenterFromGMPathType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 142 } vmwNsxTDataCenterToGMPath OBJECT-TYPE SYNTAX VmwNsxTDataCenterToGMPathType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 143 } vmwNsxTDataCenterNICThroughput OBJECT-TYPE SYNTAX VmwNsxTDataCenterNICThroughputType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 144 } vmwNsxTDataCenterNICThroughputThreshold OBJECT-TYPE SYNTAX VmwNsxTDataCenterNICThroughputThresholdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 145 } vmwNsxTDataCenterEdgeCryptoDrvName OBJECT-TYPE SYNTAX VmwNsxTDataCenterEdgeCryptoDrvNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 146 } vmwNsxTDataCenterNappNodeName OBJECT-TYPE SYNTAX VmwNsxTDataCenterNappNodeNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 147 } vmwNsxTDataCenterNewVMMorefId OBJECT-TYPE SYNTAX VmwNsxTDataCenterNewVMMorefIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 148 } vmwNsxTDataCenterPolicyEdgeVMName OBJECT-TYPE SYNTAX VmwNsxTDataCenterPolicyEdgeVMNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 149 } vmwNsxTDataCenterVMMorefId OBJECT-TYPE SYNTAX VmwNsxTDataCenterVMMorefIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 150 } vmwNsxTDataCenterDPUId OBJECT-TYPE SYNTAX VmwNsxTDataCenterDPUIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 171 } vmwNsxTDataCenterEdgeNode OBJECT-TYPE SYNTAX VmwNsxTDataCenterEdgeNodeType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 172 } vmwNsxTDataCenterPrefixesCountMax OBJECT-TYPE SYNTAX VmwNsxTDataCenterPrefixesCountMaxType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 173 } vmwNsxTDataCenterPrefixesCountThreshold OBJECT-TYPE SYNTAX VmwNsxTDataCenterPrefixesCountThresholdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 174 } vmwNsxTDataCenterRouteLimitMaximum OBJECT-TYPE SYNTAX VmwNsxTDataCenterRouteLimitMaximumType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 175 } vmwNsxTDataCenterRouteLimitThreshold OBJECT-TYPE SYNTAX VmwNsxTDataCenterRouteLimitThresholdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 176 } vmwNsxTDataCenterSubsequentAddressFamily OBJECT-TYPE SYNTAX VmwNsxTDataCenterSubsequentAddressFamilyType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 177 } vmwNsxTDataCentervCenterClusterId OBJECT-TYPE SYNTAX VmwNsxTDataCentervCenterClusterIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 179 } vmwNsxTDataCenterMpsServiceName OBJECT-TYPE SYNTAX VmwNsxTDataCenterMpsServiceNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 180 } vmwNsxTDataCenterMemberIndexId OBJECT-TYPE SYNTAX VmwNsxTDataCenterMemberIndexIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 182 } vmwNsxTDataCenterEdgeClusterId OBJECT-TYPE SYNTAX VmwNsxTDataCenterEdgeClusterIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 184 } vmwNsxTDataCenterCoreDumpCount OBJECT-TYPE SYNTAX VmwNsxTDataCenterCoreDumpCountType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 185 } vmwNsxTDataCenterNodeDisplayOrHostName OBJECT-TYPE SYNTAX VmwNsxTDataCenterNodeDisplayOrHostNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 186 } vmwNsxTDataCenterNSXEdgeTNName OBJECT-TYPE SYNTAX VmwNsxTDataCenterNSXEdgeTNNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 187 } vmwNsxTDataCenterNSXESXTNName OBJECT-TYPE SYNTAX VmwNsxTDataCenterNSXESXTNNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 188 } vmwNsxTDataCenterCollectorIP OBJECT-TYPE SYNTAX VmwNsxTDataCenterCollectorIPType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 189 } vmwNsxTDataCenterDvsAlias OBJECT-TYPE SYNTAX VmwNsxTDataCenterDvsAliasType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 190 } vmwNsxTDataCenterStackAlias OBJECT-TYPE SYNTAX VmwNsxTDataCenterStackAliasType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 191 } vmwNsxTDataCenterVerticalName OBJECT-TYPE SYNTAX VmwNsxTDataCenterVerticalNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 192 } vmwNsxTDataCenterEdgeClusterHighestHwVersion OBJECT-TYPE SYNTAX VmwNsxTDataCenterEdgeClusterHighestHwVersionType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 195 } vmwNsxTDataCenterEdgeTNHwVersion OBJECT-TYPE SYNTAX VmwNsxTDataCenterEdgeTNHwVersionType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 196 } vmwNsxTDataCenterEdgeClusterName OBJECT-TYPE SYNTAX VmwNsxTDataCenterEdgeClusterNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 197 } vmwNsxTDataCenterHaState OBJECT-TYPE SYNTAX VmwNsxTDataCenterHaStateType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 220 } vmwNsxTDataCenterHaState2 OBJECT-TYPE SYNTAX VmwNsxTDataCenterHaState2Type MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 221 } vmwNsxTDataCenterTransportNodeId2 OBJECT-TYPE SYNTAX VmwNsxTDataCenterTransportNodeId2Type MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 222 } vmwNsxTDataCenterDvsName OBJECT-TYPE SYNTAX VmwNsxTDataCenterDvsNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 223 } vmwNsxTDataCenterVtepFaultReason OBJECT-TYPE SYNTAX VmwNsxTDataCenterVtepFaultReasonType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 224 } vmwNsxTDataCenterVtepName OBJECT-TYPE SYNTAX VmwNsxTDataCenterVtepNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 225 } vmwNsxTDataCenterMetricsTargetAddress OBJECT-TYPE SYNTAX VmwNsxTDataCenterMetricsTargetAddressType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 226 } vmwNsxTDataCenterMetricsTargetAlias OBJECT-TYPE SYNTAX VmwNsxTDataCenterMetricsTargetAliasType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 227 } vmwNsxTDataCenterMetricsTargetPort OBJECT-TYPE SYNTAX VmwNsxTDataCenterMetricsTargetPortType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 228 } vmwNsxTDataCenterIPv4Address OBJECT-TYPE SYNTAX VmwNsxTDataCenterIPv4AddressType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 229 } vmwNsxTDataCenterIPv6Address OBJECT-TYPE SYNTAX VmwNsxTDataCenterIPv6AddressType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 230 } vmwNsxTDataCenterConstraintLimit OBJECT-TYPE SYNTAX VmwNsxTDataCenterConstraintLimitType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 231 } vmwNsxTDataCenterConstraintType OBJECT-TYPE SYNTAX VmwNsxTDataCenterConstraintTypeType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 232 } vmwNsxTDataCenterCurrentCount OBJECT-TYPE SYNTAX VmwNsxTDataCenterCurrentCountType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 233 } vmwNsxTDataCenterGroupId OBJECT-TYPE SYNTAX VmwNsxTDataCenterGroupIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 234 } vmwNsxTDataCenterGroupMaxNumberLimit OBJECT-TYPE SYNTAX VmwNsxTDataCenterGroupMaxNumberLimitType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 235 } vmwNsxTDataCenterGroupSize OBJECT-TYPE SYNTAX VmwNsxTDataCenterGroupSizeType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 236 } vmwNsxTDataCenterIPCount OBJECT-TYPE SYNTAX VmwNsxTDataCenterIPCountType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 237 } vmwNsxTDataCenterLrpCount OBJECT-TYPE SYNTAX VmwNsxTDataCenterLrpCountType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 238 } vmwNsxTDataCenterLspCount OBJECT-TYPE SYNTAX VmwNsxTDataCenterLspCountType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 239 } vmwNsxTDataCenterMacCount OBJECT-TYPE SYNTAX VmwNsxTDataCenterMacCountType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 240 } vmwNsxTDataCenterSidCount OBJECT-TYPE SYNTAX VmwNsxTDataCenterSidCountType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 241 } vmwNsxTDataCenterTNCount OBJECT-TYPE SYNTAX VmwNsxTDataCenterTNCountType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 244 } vmwNsxTDataCenterVifCount OBJECT-TYPE SYNTAX VmwNsxTDataCenterVifCountType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 245 } vmwNsxTDataCenterVMCount OBJECT-TYPE SYNTAX VmwNsxTDataCenterVMCountType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 246 } vmwNsxTDataCenterCoreId OBJECT-TYPE SYNTAX VmwNsxTDataCenterCoreIdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 247 } vmwNsxTDataCenterFlowCacheThreshold OBJECT-TYPE SYNTAX VmwNsxTDataCenterFlowCacheThresholdType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 248 } vmwNsxTDataCenterNSXaaSServiceName OBJECT-TYPE SYNTAX VmwNsxTDataCenterNSXaaSServiceNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 249 } vmwNsxTDataCenterProtocolName OBJECT-TYPE SYNTAX VmwNsxTDataCenterProtocolNameType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 250 } vmwNsxTDataCenterConstraintTypePath OBJECT-TYPE SYNTAX VmwNsxTDataCenterConstraintTypePathType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This value is not expected to be empty." ::= { vmwNsxTDataCenterData 251 } -- ********************************************************** -- AlarmManagement feature event notifications -- ********************************************************** vmwNsxTAlarmManagementFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the AlarmManagement feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 16 } vmwNsxTAlarmManagementFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for AlarmManagement feature notifications. " ::= { vmwNsxTAlarmManagementFeaturePrefix 0 } vmwNsxTAlarmManagementAlarmServiceOverloaded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Due to heavy volume of alarms reported, the alarm service is temporarily overloaded. The NSX UI and GET /api/v1/alarms NSX API have stopped reporting new alarms; however, syslog entries and SNMP traps (if enabled) are still being emitted reporting the underlying event details. When the underlying issues causing the heavy volume of alarms are addressed, the alarm service will start reporting new alarms again. Action required: Review all active alarms using the Alarms page in the NSX UI or using the GET /api/v1/alarms?status=OPEN,ACKNOWLEDGED,SUPPRESSED NSX API. For each active alarm investigate the root cause by following the recommended action for the alarm. When sufficient alarms are resolved, the alarm service will start reporting new alarms again. " ::= { vmwNsxTAlarmManagementFeature 1 } vmwNsxTAlarmManagementAlarmServiceOverloadedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The heavy volume of alarms has subsided and new alarms are being reported again. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTAlarmManagementFeature 2 } vmwNsxTAlarmManagementHeavyVolumeOfAlarms NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEventId } STATUS current DESCRIPTION "Due to heavy volume of vmwNsxTDataCenterEventId alarms, the alarm service has temporarily stopped reporting alarms of this type. The NSX UI and GET /api/v1/alarms NSX API are not reporting new instances of these alarms; however, syslog entries and SNMP traps (if enabled) are still being emitted reporting the underlying event details. When the underlying issues causing the heavy volume of vmwNsxTDataCenterEventId alarms are addressed, the alarm service will start reporting new vmwNsxTDataCenterEventId alarms when new issues are detected again. Action required: Review all active alarms of type vmwNsxTDataCenterEventId using the Alarms page in the NSX UI or using the NSX API GET /api/v1/alarms?status=OPEN,ACKNOWLEDGED,SUPPRESSED. For each active alarm investigate the root cause by following the recommended action for the alarm. When sufficient alarms are resolved, the alarm service will start reporting new vmwNsxTDataCenterEventId alarms again. " ::= { vmwNsxTAlarmManagementFeature 3 } vmwNsxTAlarmManagementHeavyVolumeOfAlarmsClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEventId } STATUS current DESCRIPTION "The heavy volume of vmwNsxTDataCenterEventId alarms has subsided and new alarms of this type are being reported again. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTAlarmManagementFeature 4 } -- ********************************************************** -- AuditLogHealth feature event notifications -- ********************************************************** vmwNsxTAuditLogHealthFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the AuditLogHealth feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 24 } vmwNsxTAuditLogHealthFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for AuditLogHealth feature notifications. " ::= { vmwNsxTAuditLogHealthFeaturePrefix 0 } vmwNsxTAuditLogHealthAuditLogFileUpdateError NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "At least one of the monitored log files has read-only permissions or has incorrect user/group ownership on Manager, Global Manager, Edge, Public Cloud Gateway, KVM or Linux Physical Server nodes. Or log folder is missing in Windows Physical Server nodes. Or rsyslog.log is missing on Manager, Global Manager, Edge or Public Cloud Gateway nodes. Action required: 1. On Manager and Global Managaer nodes, Edge and Public Cloud Gateway nodes, Ubuntu KVM Host nodes ensure the permissions for the /var/log directory is 775 and the ownership is root:syslog. One Rhel KVM and BMS Host nodes ensure the permission for the /var/log directory is 755 and the ownership is root:root. 2. On Manager and Global Manager nodes, ensure the file permissions for auth.log, nsx-audit.log, nsx-audit-write.log, rsyslog.log and syslog under /var/log is 640 and ownership is syslog:admin. 3. On Edge and Public Cloud Gateway nodes, ensure the file permissions for rsyslog.log and syslog under /var/log is 640 and ownership is syslog:admin. 4. On Ubuntu KVM Host and Ubuntu Physical Server nodes, ensure the file permissions of auth.log and vmware/nsx-syslog under /var/log is 640 and ownership is syslog:admin. 5. On Rhel KVM Host nodes and Centos/Rhel/Sles Physical Server nodes, ensure the file permission of vmware/nsx-syslog under /var/log is 640 and ownership is root:root. 6. If any of these files have incorrect permissions or ownership, invoke the commands `chmod ` and `chown : `. 7. If rsyslog.log is missing on Manager, Global Manager, Edge or Public Cloud Gateway nodes, invoke the NSX CLI command `restart service syslog` which restarts the logging service and regenerates /var/log/rsyslog.log. 8. On Windows Physical Server nodes, ensure the log folder: C:\ProgramData\VMware\NSX\Logs exists. If not, re-install NSX on the Windows Physical Server nodes. " ::= { vmwNsxTAuditLogHealthFeature 1 } vmwNsxTAuditLogHealthAuditLogFileUpdateErrorClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "All monitored log files have the correct file permissions and ownership and rsyslog.log exists on Manager, Global Manager, Edge or Public Cloud Gateway nodes. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTAuditLogHealthFeature 2 } vmwNsxTAuditLogHealthRemoteLoggingServerError NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterHostnameOrIPAddressWithPort } STATUS current DESCRIPTION "Log messages to logging server vmwNsxTDataCenterHostnameOrIPAddressWithPort (vmwNsxTDataCenterEntityId) cannot be delivered possibly due to an unresolvable FQDN, an invalid TLS certificate or missing NSX appliance iptables rule. Action required: 1. Ensure that vmwNsxTDataCenterHostnameOrIPAddressWithPort is the correct hostname or IP address and port. 2. If the logging server is specified using a FQDN, ensure the FQDN is resolvable from the NSX appliance using the NSX CLI command `nslookup `. If not resolvable, verify the correct FQDN is specified and the network DNS server has the required entry for the FQDN. 3. If the logging server is configured to use TLS, verify the specified certificate is valid. For example, ensure the logging server is actually using the certificate or verify the certificate has not expired using the openssl command `openssl x509 -in -noout -dates`. 4. NSX appliances use iptables rules to explicitly allow outgoing traffic. Verify the iptables rule for the logging server is configured properly by invoking the NSX CLI command `verify logging-servers` which re-configures logging server iptables rules as needed. 5. If for any reason the logging server is misconfigured, it should be deleted using the NSX CLI `del logging-server proto level ` command and re-added with the correct configuration. " ::= { vmwNsxTAuditLogHealthFeature 3 } vmwNsxTAuditLogHealthRemoteLoggingServerErrorClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterHostnameOrIPAddressWithPort } STATUS current DESCRIPTION "Configuration for logging server vmwNsxTDataCenterHostnameOrIPAddressWithPort (vmwNsxTDataCenterEntityId) appear correct. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTAuditLogHealthFeature 4 } -- ********************************************************** -- Capacity feature event notifications -- ********************************************************** vmwNsxTCapacityFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the Capacity feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 22 } vmwNsxTCapacityFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for Capacity feature notifications. " ::= { vmwNsxTCapacityFeaturePrefix 0 } vmwNsxTCapacityMaximumCapacity NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterCapacityDisplayName, vmwNsxTDataCenterCapacityUsageCount, vmwNsxTDataCenterMaxSupportedCapacityCount } STATUS current DESCRIPTION "The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount which is above the maximum supported count of vmwNsxTDataCenterMaxSupportedCapacityCount. Action required: Ensure that the number of NSX objects created is within the limits supported by NSX. If there are any unused objects, delete them using the respective NSX UI or API from the system. Consider increasing the form factor of all Manager nodes and/or Edge nodes. Note that the form factor of each node type should be the same. If not the same, the capacity limits for the lowest form factor deployed are used. " ::= { vmwNsxTCapacityFeature 1 } vmwNsxTCapacityMaximumCapacityClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterCapacityDisplayName, vmwNsxTDataCenterCapacityUsageCount, vmwNsxTDataCenterMaxSupportedCapacityCount } STATUS current DESCRIPTION "The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount and is at or below the maximum supported count of vmwNsxTDataCenterMaxSupportedCapacityCount. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCapacityFeature 2 } vmwNsxTCapacityMaximumCapacityThreshold NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterCapacityDisplayName, vmwNsxTDataCenterCapacityUsageCount, vmwNsxTDataCenterMaxCapacityThreshold } STATUS current DESCRIPTION "The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount which is above the maximum capacity threshold of vmwNsxTDataCenterMaxCapacityThreshold%. Action required: Navigate to the capacity page in the NSX UI and review current usage versus threshold limits. If the current usage is expected, consider increasing the maximum threshold values. If the current usage is unexpected, review the network policies configured to decrease usage at or below the maximum threshold. " ::= { vmwNsxTCapacityFeature 3 } vmwNsxTCapacityMaximumCapacityThresholdClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterCapacityDisplayName, vmwNsxTDataCenterCapacityUsageCount, vmwNsxTDataCenterMaxCapacityThreshold } STATUS current DESCRIPTION "The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount and is at or below the maximum capacity threshold of vmwNsxTDataCenterMaxCapacityThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCapacityFeature 4 } vmwNsxTCapacityMinimumCapacityThreshold NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterCapacityDisplayName, vmwNsxTDataCenterCapacityUsageCount, vmwNsxTDataCenterMinCapacityThreshold } STATUS current DESCRIPTION "The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount which is above the minimum capacity threshold of vmwNsxTDataCenterMinCapacityThreshold%. Action required: Navigate to the capacity page in the NSX UI and review current usage versus threshold limits. If the current usage is expected, consider increasing the minimum threshold values. If the current usage is unexpected, review the network policies configured to decrease usage at or below the minimum threshold. " ::= { vmwNsxTCapacityFeature 5 } vmwNsxTCapacityMinimumCapacityThresholdClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterCapacityDisplayName, vmwNsxTDataCenterCapacityUsageCount, vmwNsxTDataCenterMinCapacityThreshold } STATUS current DESCRIPTION "The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount and is at or below the minimum capacity threshold of vmwNsxTDataCenterMinCapacityThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCapacityFeature 6 } -- ********************************************************** -- Certificates feature event notifications -- ********************************************************** vmwNsxTCertificatesFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the Certificates feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 3 } vmwNsxTCertificatesFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for Certificates feature notifications. " ::= { vmwNsxTCertificatesFeaturePrefix 0 } vmwNsxTCertificatesCABundleUpdateRecommended NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterCABundleAgeThreshold } STATUS current DESCRIPTION "The trusted CA bundle vmwNsxTDataCenterEntityId was updated more than vmwNsxTDataCenterCABundleAgeThreshold days ago. Update for the trusted CA bundle is recommended. Action required: Ensure services that are currently using the trusted CA bundle are updated to use a recently-updated trusted CA bundle. Unless it is system-provided bundle, the bundle can be updated using the PUT /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API. Once the expired bundle is no longer in use, it should be deleted (if not system-provided) by invoking the DELETE /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API. " ::= { vmwNsxTCertificatesFeature 7 } vmwNsxTCertificatesCABundleUpdateRecommendedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The trusted CA bundle vmwNsxTDataCenterEntityId has been removed, updated, or is no longer in use. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCertificatesFeature 8 } vmwNsxTCertificatesCABundleUpdateSuggested NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterCABundleAgeThreshold } STATUS current DESCRIPTION "The trusted CA bundle vmwNsxTDataCenterEntityId was updated more than vmwNsxTDataCenterCABundleAgeThreshold days ago. Update for the trusted CA bundle is suggested. Action required: Ensure services that are currently using the trusted CA bundle are updated to use a recently-updated trusted CA bundle. Unless it is system-provided bundle, the bundle can be updated using the PUT /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API. Once the expired bundle is no longer in use, it should be deleted (if not system-provided) by invoking the DELETE /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API. " ::= { vmwNsxTCertificatesFeature 9 } vmwNsxTCertificatesCABundleUpdateSuggestedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The trusted CA bundle vmwNsxTDataCenterEntityId has been removed, updated, or is no longer in use. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCertificatesFeature 10 } vmwNsxTCertificatesCertificateExpirationApproaching NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterAPICollectionPath } STATUS current DESCRIPTION "Certificate vmwNsxTDataCenterEntityId is approaching expiration. Action required: Ensure services that are currently using the certificate are updated to use a new, non-expiring certificate. Once the expiring certificate is no longer in use, it should be deleted by invoking the DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API. " ::= { vmwNsxTCertificatesFeature 1 } vmwNsxTCertificatesCertificateExpirationApproachingClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The expiring certificate vmwNsxTDataCenterEntityId has been removed or is no longer approaching expiration. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCertificatesFeature 2 } vmwNsxTCertificatesCertificateExpired NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterAPICollectionPath } STATUS current DESCRIPTION "Certificate vmwNsxTDataCenterEntityId has expired. Action required: Ensure services that are currently using the certificate are updated to use a new, non-expired certificate. Once the expired certificate is no longer in use, it should be deleted by invoking the DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API. If the expired certificate is used by NAPP Platform, the connection is broken between NSX and NAPP Platform. Check the NAPP Platform troubleshooting document to use a self-signed NAPP CA certificate for recovering the connection. For more information see: https://www.vmware.com/esx/support/askvmware/index.php?eventtype=certificates.certificate_expired " ::= { vmwNsxTCertificatesFeature 3 } vmwNsxTCertificatesCertificateExpiredClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The expired certificate vmwNsxTDataCenterEntityId has been removed or is no longer expired. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCertificatesFeature 4 } vmwNsxTCertificatesCertificateIsAboutToExpire NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterAPICollectionPath } STATUS current DESCRIPTION "Certificate vmwNsxTDataCenterEntityId is about to expire. Action required: Ensure services that are currently using the certificate are updated to use a new, non-expiring certificate. Once the expiring certificate is no longer in use, it should be deleted by invoking the DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API. " ::= { vmwNsxTCertificatesFeature 5 } vmwNsxTCertificatesCertificateIsAboutToExpireClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The expiring certificate vmwNsxTDataCenterEntityId has been removed or is no longer about to expire. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCertificatesFeature 6 } vmwNsxTCertificatesTransportNodeCertificateExpirApproaching NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Certificate for Transport node vmwNsxTDataCenterEntityId is approaching expiration. Action required: Replace the Transport node vmwNsxTDataCenterEntityId certificate with a non-expired certificate. The expired certificate should be replaced by invoking the POST /api/v1/trust-management/certificates/action/replace-host-certificate/vmwNsxTDataCenterEntityId NSX API. If the certificate is not replaced, when the certificate expires the connection between the Transport node and the Manager node will be broken. " ::= { vmwNsxTCertificatesFeature 17 } vmwNsxTCertificatesTransportNodeCertificateExpirApproachingClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The expiring certificate for Transport node vmwNsxTDataCenterEntityId has been removed or is no longer approaching expiration. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCertificatesFeature 18 } vmwNsxTCertificatesTransportNodeCertificateExpired NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Certificate has expired for Transport node vmwNsxTDataCenterEntityId. Action required: Replace the Transport node vmwNsxTDataCenterEntityId certificate with a non-expired certificate. The expired certificate should be replaced by invoking the POST /api/v1/trust-management/certificates/action/replace-host-certificate/vmwNsxTDataCenterEntityId NSX API. If the expired certificate is used by Transport node, the connection is broken between Transport node and Manager node. " ::= { vmwNsxTCertificatesFeature 19 } vmwNsxTCertificatesTransportNodeCertificateExpiredClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The expired certificate for Transport node vmwNsxTDataCenterEntityId has been replaced or is no longer expired. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCertificatesFeature 20 } vmwNsxTCertificatesTransportNodeCertificateIsAboutToExpire NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Certificate for Transport node vmwNsxTDataCenterEntityId is about to expire. Action required: Replace the Transport node vmwNsxTDataCenterEntityId certificate with a non-expired certificate. The expired certificate should be replaced by invoking the POST /api/v1/trust-management/certificates/action/replace-host-certificate/vmwNsxTDataCenterEntityId NSX API. If the certificate is not replaced, when the certificate expires the connection between the Transport node and the Manager node will be broken. " ::= { vmwNsxTCertificatesFeature 21 } vmwNsxTCertificatesTransportNodeCertificateIsAboutToExpireClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The expiring certificate for Transport node vmwNsxTDataCenterEntityId has been removed or is no longer about to expire. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCertificatesFeature 22 } -- ********************************************************** -- Clustering feature event notifications -- ********************************************************** vmwNsxTClusteringFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the Clustering feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 40 } vmwNsxTClusteringFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for Clustering feature notifications. " ::= { vmwNsxTClusteringFeaturePrefix 0 } vmwNsxTClusteringClusterDegraded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterManagerNodeId, vmwNsxTDataCenterGroupType } STATUS current DESCRIPTION "Group member vmwNsxTDataCenterManagerNodeId of service vmwNsxTDataCenterGroupType is down. Action required: 1. Invoke the NSX CLI command 'get cluster status' to view the status of group members of the cluster. 2. Ensure the service for vmwNsxTDataCenterGroupType is running on node. Invoke the GET /api/v1/node/services//status NSX API or the `get service ` NSX CLI command to determine if the service is running. If not running, invoke the POST /api/v1/node/services/?action=restart NSX API or the `restart service ` NSX CLI to restart the service. 3. Check /var/log/ of service vmwNsxTDataCenterGroupType to see if there are errors reported. " ::= { vmwNsxTClusteringFeature 1 } vmwNsxTClusteringClusterDegradedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterManagerNodeId, vmwNsxTDataCenterGroupType } STATUS current DESCRIPTION "Group member vmwNsxTDataCenterManagerNodeId of vmwNsxTDataCenterGroupType is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTClusteringFeature 2 } vmwNsxTClusteringClusterUnavailable NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterManagerNodeIDS, vmwNsxTDataCenterGroupType } STATUS current DESCRIPTION "All group members vmwNsxTDataCenterManagerNodeIDS of service vmwNsxTDataCenterGroupType are down. Action required: 1. Ensure the service for vmwNsxTDataCenterGroupType is running on node. Invoke the GET /api/v1/node/services//status NSX API or the `get service ` NSX CLI command to determine if the service is running. If not running, invoke the POST /api/v1/node/services/?action=restart NSX API or the `restart service ` NSX CLI to restart the service. 2. Check /var/log/ of service vmwNsxTDataCenterGroupType to see if there are errors reported. " ::= { vmwNsxTClusteringFeature 3 } vmwNsxTClusteringClusterUnavailableClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterManagerNodeIDS, vmwNsxTDataCenterGroupType } STATUS current DESCRIPTION "All group members vmwNsxTDataCenterManagerNodeIDS of service vmwNsxTDataCenterGroupType are up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTClusteringFeature 4 } -- ********************************************************** -- CniHealth feature event notifications -- ********************************************************** vmwNsxTCniHealthFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the CniHealth feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 10 } vmwNsxTCniHealthFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for CniHealth feature notifications. " ::= { vmwNsxTCniHealthFeaturePrefix 0 } vmwNsxTCniHealthHyperbusManagerConnectionDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Hyperbus cannot communicate with the Manager node. Action required: The hyperbus vmkernel interface (vmk50) may be missing. Refer to Knowledge Base article https://kb.vmware.com/s/article/67432. " ::= { vmwNsxTCniHealthFeature 3 } vmwNsxTCniHealthHyperbusManagerConnectionDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Hyperbus can communicate with the Manager node. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCniHealthFeature 4 } vmwNsxTCniHealthHyperbusManagerConnectionDownOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "Hyperbus on DPU vmwNsxTDataCenterDPUId cannot communicate with the Manager node. Action required: The hyperbus vmkernel interface (vmk50) on DPU vmwNsxTDataCenterDPUId may be missing. Refer to Knowledge Base article https://kb.vmware.com/s/article/67432. " ::= { vmwNsxTCniHealthFeature 5 } vmwNsxTCniHealthHyperbusManagerConnectionDownOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "Hyperbus on DPU vmwNsxTDataCenterDPUId can communicate with the Manager node. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCniHealthFeature 6 } -- ********************************************************** -- Communication feature event notifications -- ********************************************************** vmwNsxTCommunicationFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the Communication feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 35 } vmwNsxTCommunicationFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for Communication feature notifications. " ::= { vmwNsxTCommunicationFeaturePrefix 0 } vmwNsxTCommunicationControlChannelToManagerNodeDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterApplianceAddress, vmwNsxTDataCenterTimeoutInMinutes } STATUS current DESCRIPTION "The Transport node vmwNsxTDataCenterEntityId control plane connection to Manager node vmwNsxTDataCenterApplianceAddress is down for at least vmwNsxTDataCenterTimeoutInMinutes minutes from the Transport node's point of view. Action required: 1. Check the connectivity from Transport node vmwNsxTDataCenterEntityId to Manager node vmwNsxTDataCenterApplianceAddress interface via ping. If they are not pingable, check for flakiness in network connectivity. 2. Check to see if the TCP connections are established using the netstat output to see if the Controller service on the Manager node vmwNsxTDataCenterApplianceAddress is listening for connections on port 1235. If not, check firewall (or) iptables rules to see if port 1235 is blocking Transport node vmwNsxTDataCenterEntityId connection requests. Ensure that there are no host firewalls or network firewalls in the underlay are blocking the required IP ports between Manager nodes and Transport nodes. This is documented in our ports and protocols tool which is here: https://ports.vmware.com/. 3. It is possible that the Transport node vmwNsxTDataCenterEntityId may still be in maintenance mode. You can check whether the Transport node is in maintenance mode via the following API: GET https:///api/v1/transport-nodes/ When maintenance mode is set, the Transport node will not be connected to the Controller service. This is usually the case when host upgrade is in progress. Wait for a few minutes and check connectivity again. Note: This alarm is not critical and should be resolved. GSS need not be contacted for the notification of this alarm unless the alarm remains unresolved over an extended period of time. " ::= { vmwNsxTCommunicationFeature 7 } vmwNsxTCommunicationControlChannelToManagerNodeDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterApplianceAddress } STATUS current DESCRIPTION "The Transport node vmwNsxTDataCenterEntityId restores the control plane connection to Manager node vmwNsxTDataCenterApplianceAddress. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 8 } vmwNsxTCommunicationControlChannelToManagerNodeDownTooLong NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterApplianceAddress, vmwNsxTDataCenterTimeoutInMinutes } STATUS current DESCRIPTION "The Transport node vmwNsxTDataCenterEntityId control plane connection to Manager node vmwNsxTDataCenterApplianceAddress is down for at least vmwNsxTDataCenterTimeoutInMinutes minutes from the Transport node's point of view. Action required: 1. Check the connectivity from Transport node vmwNsxTDataCenterEntityId to Manager node vmwNsxTDataCenterApplianceAddress interface via ping. If they are not pingable, check for flakiness in network connectivity. 2. Check to see if the TCP connections are established using the netstat output to see if the Controller service on the Manager node vmwNsxTDataCenterApplianceAddress is listening for connections on port 1235. If not, check firewall (or) iptables rules to see if port 1235 is blocking Transport node vmwNsxTDataCenterEntityId connection requests. Ensure that there are no host firewalls or network firewalls in the underlay are blocking the required IP ports between Manager nodes and Transport nodes. This is documented in our ports and protocols tool which is here: https://ports.vmware.com/. 3. It is possible that the Transport node vmwNsxTDataCenterEntityId may still be in maintenance mode. You can check whether the Transport node is in maintenance mode via the following API: GET https:///api/v1/transport-nodes/. When maintenance mode is set, the Transport node will not be connected to the Controller service. This is usually the case when host upgrade is in progress. Wait for a few minutes and check connectivity again. " ::= { vmwNsxTCommunicationFeature 9 } vmwNsxTCommunicationControlChannelToManagerNodeDownTooLongClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterApplianceAddress } STATUS current DESCRIPTION "The Transport node vmwNsxTDataCenterEntityId restores the control plane connection to Manager node vmwNsxTDataCenterApplianceAddress. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 10 } vmwNsxTCommunicationControlChannelToTransportNodeDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterApplianceAddress, vmwNsxTDataCenterCentralControlPlaneId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "Controller service on Manager node vmwNsxTDataCenterApplianceAddress (vmwNsxTDataCenterCentralControlPlaneId) to Transport node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) down for at least three minutes from Controller service's point of view. Action required: 1. Check the connectivity from the Controller service vmwNsxTDataCenterCentralControlPlaneId and Transport node vmwNsxTDataCenterEntityId interface via ping and traceroute. This can be done on the NSX Manager node admin CLI. The ping test should not see drops and have consistent latency values. VMware recommends latency values of 150ms or less. 2. Navigate to System | Fabric | Nodes | Transport node vmwNsxTDataCenterEntityId on the NSX UI to check if the TCP connections between the Controller service on Manager node vmwNsxTDataCenterApplianceAddress (vmwNsxTDataCenterCentralControlPlaneId) and Transport node vmwNsxTDataCenterEntityId is established. If not, check firewall rules on the network and the hosts to see if port 1235 is blocking Transport node vmwNsxTDataCenterEntityId connection requests. Ensure that there are no host firewalls or network firewalls in the underlay are blocking the required IP ports between Manager nodes and Transport nodes. This is documented in our ports and protocols tool which is here: https://ports.vmware.com/. " ::= { vmwNsxTCommunicationFeature 11 } vmwNsxTCommunicationControlChannelToTransportNodeDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterApplianceAddress, vmwNsxTDataCenterCentralControlPlaneId } STATUS current DESCRIPTION "Controller service on Manager node vmwNsxTDataCenterApplianceAddress (vmwNsxTDataCenterCentralControlPlaneId) restores connection to Transport node vmwNsxTDataCenterEntityId. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 12 } vmwNsxTCommunicationControlChannelToTransportNodeDownLong NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterApplianceAddress, vmwNsxTDataCenterCentralControlPlaneId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "Controller service on Manager node vmwNsxTDataCenterApplianceAddress (vmwNsxTDataCenterCentralControlPlaneId) to Transport node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) down for at least 15 minutes from Controller service's point of view. Action required: 1. Check the connectivity from the Controller service vmwNsxTDataCenterCentralControlPlaneId and Transport node vmwNsxTDataCenterEntityId interface via ping and traceroute. This can be done on the NSX Manager node admin CLI. The ping test should not see drops and have consistent latency values. VMware recommends latency values of 150ms or less. 2. Navigate to System | Fabric | Nodes | Transport node vmwNsxTDataCenterEntityId on the NSX UI to check if the TCP connections between the Controller service on Manager node vmwNsxTDataCenterApplianceAddress (vmwNsxTDataCenterCentralControlPlaneId) and Transport node vmwNsxTDataCenterEntityId is established. If not, check firewall rules on the network and the hosts to see if port 1235 is blocking Transport node vmwNsxTDataCenterEntityId connection requests. Ensure that there are no host firewalls or network firewalls in the underlay are blocking the required IP ports between Manager nodes and Transport nodes. This is documented in our ports and protocols tool which is here: https://ports.vmware.com/. " ::= { vmwNsxTCommunicationFeature 19 } vmwNsxTCommunicationControlChannelToTransportNodeDownLongClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterApplianceAddress, vmwNsxTDataCenterCentralControlPlaneId } STATUS current DESCRIPTION "Controller service on Manager node vmwNsxTDataCenterApplianceAddress (vmwNsxTDataCenterCentralControlPlaneId) restores connection to Transport node vmwNsxTDataCenterEntityId. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 20 } vmwNsxTCommunicationLimitedReachabilityOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVerticalName, vmwNsxTDataCenterCollectorIP, vmwNsxTDataCenterStackAlias, vmwNsxTDataCenterDvsAlias, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "The vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP can not be reached via vmknic(s)(stack vmwNsxTDataCenterStackAlias) on DVS vmwNsxTDataCenterDvsAlias on DPU vmwNsxTDataCenterDPUId, but is reachable via vmknic(s)(stack vmwNsxTDataCenterStackAlias) on other DVS(es). Action required: If the warning is on, it does not mean the collector is unreachable. The exported flows generated by the vertical based on DVS vmwNsxTDataCenterDvsAlias can still reach the collector vmwNsxTDataCenterCollectorIP via vmknic(s) on DVS(es) besides of DVS vmwNsxTDataCenterDvsAlias. If this is unacceptable, user can try to create vmknic(s) with stack vmwNsxTDataCenterStackAlias on DVS vmwNsxTDataCenterDvsAlias and configure it with approriate IPv4(6) address, then check if the vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP can be reached via the newly-created vmknic(s) on DPU vmwNsxTDataCenterDPUId by invoking `vmkping vmwNsxTDataCenterCollectorIP -S vmwNsxTDataCenterStackAlias -I vmkX` with SSH to DPU via ESXi enabled. " ::= { vmwNsxTCommunicationFeature 31 } vmwNsxTCommunicationLimitedReachabilityOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVerticalName, vmwNsxTDataCenterCollectorIP, vmwNsxTDataCenterStackAlias, vmwNsxTDataCenterDvsAlias, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "The vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP can be reached via vmknic(s) (stack vmwNsxTDataCenterStackAlias) on DVS vmwNsxTDataCenterDvsAlias on DPU vmwNsxTDataCenterDPUId, or the vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP is unreachable completely. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 32 } vmwNsxTCommunicationManagementChannelToManagerNodeDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterManagerNodeId, vmwNsxTDataCenterApplianceAddress, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "Management channel to Manager Node vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress) is down for 5 minutes. Action required: Ensure there is network connectivity between the Transport node vmwNsxTDataCenterTransportNodeId and master Manager node. Also ensure no firewalls are blocking traffic between the nodes. Ensure the messaging manager service is running on Manager nodes by invoking the command `/etc/init.d/messaging-manager status`. If the messaging manager is not running, restart it by invoking the command `/etc/init.d/messaging-manager restart`. " ::= { vmwNsxTCommunicationFeature 13 } vmwNsxTCommunicationManagementChannelToManagerNodeDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterManagerNodeId, vmwNsxTDataCenterApplianceAddress } STATUS current DESCRIPTION "Management channel to Manager Node vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress) is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 14 } vmwNsxTCommunicationManagementChannelToManagerNodeDownLong NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterManagerNodeId, vmwNsxTDataCenterApplianceAddress, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "Management channel to Manager Node vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress) is down for 15 minutes. Action required: Ensure there is network connectivity between the Transport node vmwNsxTDataCenterTransportNodeId and master Manager nodes. Also ensure no firewalls are blocking traffic between the nodes. Ensure the messaging manager service is running on Manager nodes by invoking the command `/etc/init.d/messaging-manager status`. If the messaging manager is not running, restart it by invoking the command `/etc/init.d/messaging-manager restart`. " ::= { vmwNsxTCommunicationFeature 25 } vmwNsxTCommunicationManagementChannelToManagerNodeDownLongClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterManagerNodeId, vmwNsxTDataCenterApplianceAddress } STATUS current DESCRIPTION "Management channel to Manager Node vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress) is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 26 } vmwNsxTCommunicationManagementChannelToTransportNodeDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterTransportNodeAddress } STATUS current DESCRIPTION "Management channel to Transport Node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) is down for 5 minutes. Action required: Ensure there is network connectivity between the Manager nodes and Transport node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) and no firewalls are blocking traffic between the nodes. On Windows Transport nodes, ensure the nsx-proxy service is running on the Transport node by invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 status` in the Windows PowerShell. If it is not running, restart it by invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 restart`. On all other Transport nodes, ensure the nsx-proxy service is running on the Transport node by invoking the command `/etc/init.d/nsx-proxy status`. If it is not running, restart it by invoking the command `/etc/init.d/nsx-proxy restart`. " ::= { vmwNsxTCommunicationFeature 1 } vmwNsxTCommunicationManagementChannelToTransportNodeDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterTransportNodeAddress } STATUS current DESCRIPTION "Management channel to Transport Node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 2 } vmwNsxTCommunicationManagementChannelToTransportNodeDownLg NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterTransportNodeAddress } STATUS current DESCRIPTION "Management channel to Transport Node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) is down for 15 minutes. Action required: Ensure there is network connectivity between the Manager nodes and Transport node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) and no firewalls are blocking traffic between the nodes. On Windows Transport nodes, ensure the nsx-proxy service is running on the Transport node by invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 status` in the Windows PowerShell. If it is not running, restart it by invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 restart`. On all other Transport nodes, ensure the nsx-proxy service is running on the Transport node by invoking the command `/etc/init.d/nsx-proxy status`. If it is not running, restart it by invoking the command `/etc/init.d/nsx-proxy restart`. " ::= { vmwNsxTCommunicationFeature 5 } vmwNsxTCommunicationManagementChannelToTransportNodeDownLgClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterTransportNodeAddress } STATUS current DESCRIPTION "Management channel to Transport Node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 6 } vmwNsxTCommunicationManagerClusterLatencyHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterManagerNodeId, vmwNsxTDataCenterApplianceAddress, vmwNsxTDataCenterRemoteManagerNodeId, vmwNsxTDataCenterRemoteApplianceAddress } STATUS current DESCRIPTION "The average network latency between Manager nodes vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress) and vmwNsxTDataCenterRemoteManagerNodeId (vmwNsxTDataCenterRemoteApplianceAddress) is more than 10ms for the last 5 minutes. Action required: Ensure there are no firewall rules blocking ping traffic between the Manager nodes. If there are other high bandwidth servers and applications sharing the local network, consider moving these to a different network. " ::= { vmwNsxTCommunicationFeature 17 } vmwNsxTCommunicationManagerClusterLatencyHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterManagerNodeId, vmwNsxTDataCenterApplianceAddress, vmwNsxTDataCenterRemoteManagerNodeId, vmwNsxTDataCenterRemoteApplianceAddress } STATUS current DESCRIPTION "The average network latency between Manager nodes vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress) and vmwNsxTDataCenterRemoteManagerNodeId (vmwNsxTDataCenterRemoteApplianceAddress) is within 10ms. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 18 } vmwNsxTCommunicationManagerControlChannelDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterManagerNodeName, vmwNsxTDataCenterApplianceAddress } STATUS current DESCRIPTION "The communication between the management function and the control function has failed on Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterApplianceAddress). Action required: 1. On Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterApplianceAddress), invoke the following NSX CLI command: `get service applianceproxy` to check the status of the service periodically for 60 minutes. 2. If the service is not running for more than 60 minutes, invoke the following NSX CLI command: `restart service applianceproxy` and recheck the status. If the service is still down, contact VMware support. " ::= { vmwNsxTCommunicationFeature 3 } vmwNsxTCommunicationManagerControlChannelDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterManagerNodeName, vmwNsxTDataCenterApplianceAddress } STATUS current DESCRIPTION "The communication between the management function and the control function has been restored on Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterApplianceAddress). Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 4 } vmwNsxTCommunicationManagerFQDNLookupFailure NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterApplianceFQDN } STATUS current DESCRIPTION "DNS lookup failed for Manager node vmwNsxTDataCenterEntityId with FQDN vmwNsxTDataCenterApplianceFQDN and the publish_fqdns flag was set. Action required: 1. Assign correct FQDNs to all Manager nodes and verify the DNS configuration is correct for successful lookup of all Manager nodes' FQDNs. 2. Alternatively, disable the use of FQDNs by invoking the NSX API PUT /api/v1/configs/management with publish_fqdns set to false in the request body. After that calls from Transport nodes and from Federation to Manager nodes in this cluster will use only IP addresses. " ::= { vmwNsxTCommunicationFeature 21 } vmwNsxTCommunicationManagerFQDNLookupFailureClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterApplianceFQDN } STATUS current DESCRIPTION "FQDN lookup succeeded for Manager node vmwNsxTDataCenterEntityId with FQDN vmwNsxTDataCenterApplianceFQDN or the publish_fqdns flag was cleared. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 22 } vmwNsxTCommunicationManagerFQDNReverseLookupFailure NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterApplianceAddress } STATUS current DESCRIPTION "Reverse DNS lookup failed for Manager node vmwNsxTDataCenterEntityId with IP address vmwNsxTDataCenterApplianceAddress and the publish_fqdns flag was set. Action required: 1. Assign correct FQDNs to all Manager nodes and verify the DNS configuration is correct for successful reverse lookup of the Manager node's IP address. 2. Alternatively, disable the use of FQDNs by invoking the NSX API PUT /api/v1/configs/management with publish_fqdns set to false in the request body. After that calls from Transport nodes and from Federation to Manager nodes in this cluster will use only IP addresses. " ::= { vmwNsxTCommunicationFeature 23 } vmwNsxTCommunicationManagerFQDNReverseLookupFailureClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterApplianceAddress } STATUS current DESCRIPTION "Reverse DNS lookup succeeded for Manager node vmwNsxTDataCenterEntityId with IP address vmwNsxTDataCenterApplianceAddress or the publish_fqdns flag was cleared. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 24 } vmwNsxTCommunicationNetworkLatencyHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterTransportNodeAddress } STATUS current DESCRIPTION "The average network latency between manager nodes and host vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) is more than 150 ms for 5 minutes. Action required: 1. Wait for 5 minutes to see if the alarm automatically gets resolved. 2. Ping the NSX Transport node from Manager node. The ping test should not see drops and have consistent latency values. VMware recommends latency values of 150ms or less. 3. Inspect for any other physical network layer issues. If the problem persists, contact VMware support. " ::= { vmwNsxTCommunicationFeature 29 } vmwNsxTCommunicationNetworkLatencyHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterTransportNodeAddress } STATUS current DESCRIPTION "The average network latency between manager nodes and host vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) is normal. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 30 } vmwNsxTCommunicationUnreachableCollectorOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVerticalName, vmwNsxTDataCenterCollectorIP, vmwNsxTDataCenterStackAlias, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "The vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP can not be reached via existing vmknic(s)(stack vmwNsxTDataCenterStackAlias) on any DVS on DPU vmwNsxTDataCenterDPUId. Action required: To make the collector reachable for given vertical on the DVS, user has to make sure there is(are) vmknic(s) with expected stack vmwNsxTDataCenterStackAlias created and configured with approriate IPv4(6) addresses, and the network connection to vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP is also fine. So user has to do the checking on DPU vmwNsxTDataCenterDPUId, and perform required configuration to make sure the condition is met. Finally if `vmkping vmwNsxTDataCenterCollectorIP -S vmwNsxTDataCenterStackAlias` with SSH to DPU via ESXi enabled succeeds, this indicates the problem is gone. " ::= { vmwNsxTCommunicationFeature 33 } vmwNsxTCommunicationUnreachableCollectorOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVerticalName, vmwNsxTDataCenterCollectorIP, vmwNsxTDataCenterStackAlias, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "The vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP can be reached with existing vmknic(s)(stack vmwNsxTDataCenterStackAlias) now on DPU vmwNsxTDataCenterDPUId. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTCommunicationFeature 34 } -- ********************************************************** -- DHCP feature event notifications -- ********************************************************** vmwNsxTDHCPFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the DHCP feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 20 } vmwNsxTDHCPFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for DHCP feature notifications. " ::= { vmwNsxTDHCPFeaturePrefix 0 } vmwNsxTDHCPPoolLeaseAllocationFailed NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDHCPServerId } STATUS current DESCRIPTION "The addresses in IP Pool vmwNsxTDataCenterEntityId of DHCP Server vmwNsxTDataCenterDHCPServerId have been exhausted. The last DHCP request has failed and future requests will fail. Action required: Review the DHCP pool configuration in the NSX UI or on the Edge node where the DHCP server is running by invoking the NSX CLI command `get dhcp ip-pool`. Also review the current active leases on the Edge node by invoking the NSX CLI command `get dhcp lease`. Compare the leases to the number of active VMs. Consider reducing the lease time on the DHCP server configuration if the number of VMs are low compared to the number of active leases. Also consider expanding the pool range for the DHCP server by visiting the Networking | Segments | Segment page in the NSX UI. " ::= { vmwNsxTDHCPFeature 1 } vmwNsxTDHCPPoolLeaseAllocationFailedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDHCPServerId } STATUS current DESCRIPTION "IP Pool vmwNsxTDataCenterEntityId of DHCP Server vmwNsxTDataCenterDHCPServerId is no longer exhausted. A lease is successfully allocated to the last DHCP request. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDHCPFeature 2 } vmwNsxTDHCPPoolOverloaded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDHCPServerId, vmwNsxTDataCenterDHCPPoolUsage } STATUS current DESCRIPTION "The DHCP Server vmwNsxTDataCenterDHCPServerId IP Pool vmwNsxTDataCenterEntityId usage is approaching exhaustion with vmwNsxTDataCenterDHCPPoolUsage% IPs allocated. Action required: Review the DHCP pool configuration in the NSX UI or on the Edge node where the DHCP server is running by invoking the NSX CLI command `get dhcp ip-pool`. Also review the current active leases on the Edge node by invoking the NSX CLI command `get dhcp lease`. Compare the leases to the number of active VMs. Consider reducing the lease time on the DHCP server configuration if the number of VMs are low compared to the number of active leases. Also consider expanding the pool range for the DHCP server by visiting the Networking | Segments | Segment page in the NSX UI. " ::= { vmwNsxTDHCPFeature 3 } vmwNsxTDHCPPoolOverloadedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDHCPServerId } STATUS current DESCRIPTION "The DHCP Server vmwNsxTDataCenterDHCPServerId IP Pool vmwNsxTDataCenterEntityId has fallen below the high usage threshold. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDHCPFeature 4 } -- ********************************************************** -- DistributedFirewall feature event notifications -- ********************************************************** vmwNsxTDistributedFirewallFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the DistributedFirewall feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 31 } vmwNsxTDistributedFirewallFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for DistributedFirewall feature notifications. " ::= { vmwNsxTDistributedFirewallFeaturePrefix 0 } vmwNsxTDistributedFirewallDFWCPUUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Consider re-balancing the VM workloads on this host to other hosts. Review the security design for optimization. For example, use the apply-to configuration if the rules are not applicable to the entire datacenter. " ::= { vmwNsxTDistributedFirewallFeature 1 } vmwNsxTDistributedFirewallDFWCPUUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedFirewallFeature 2 } vmwNsxTDistributedFirewallDFWCPUUsageVeryHighOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterDPUId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Consider re-balancing the VM workloads on this host to other hosts. Review the security design for optimization. For example, use the apply-to configuration if the rules are not applicable to the entire datacenter. " ::= { vmwNsxTDistributedFirewallFeature 17 } vmwNsxTDistributedFirewallDFWCPUUsageVeryHighOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterDPUId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedFirewallFeature 18 } vmwNsxTDistributedFirewallDFWFloodLimitCritical NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterProtocolName } STATUS current DESCRIPTION "The DFW flood limit for DFW filter vmwNsxTDataCenterEntityId on host vmwNsxTDataCenterTransportNodeName has reached critical level of 98% of the configured limit for protocol vmwNsxTDataCenterProtocolName. Action required: Check VMs on the host in NSX Manager, check configured flood critical level of the DFW filter vmwNsxTDataCenterEntityId for protocol vmwNsxTDataCenterProtocolName. " ::= { vmwNsxTDistributedFirewallFeature 23 } vmwNsxTDistributedFirewallDFWFloodLimitCriticalClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterProtocolName } STATUS current DESCRIPTION "The critical flood limit condition for DFW filter vmwNsxTDataCenterEntityId on host vmwNsxTDataCenterTransportNodeName for protocol vmwNsxTDataCenterProtocolName is cleared. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedFirewallFeature 24 } vmwNsxTDistributedFirewallDFWFloodLimitWarning NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterProtocolName } STATUS current DESCRIPTION "The DFW flood limit for DFW filter vmwNsxTDataCenterEntityId on host vmwNsxTDataCenterTransportNodeName has reached warning level of 80% of the configured limit for protocol vmwNsxTDataCenterProtocolName. Action required: Check VMs on the host in NSX Manager, check configured flood warning level of the DFW filter vmwNsxTDataCenterEntityId for protocol vmwNsxTDataCenterProtocolName. " ::= { vmwNsxTDistributedFirewallFeature 21 } vmwNsxTDistributedFirewallDFWFloodLimitWarningClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterProtocolName } STATUS current DESCRIPTION "The warning flood limit condition for DFW filter vmwNsxTDataCenterEntityId on host vmwNsxTDataCenterTransportNodeName for protocol vmwNsxTDataCenterProtocolName is cleared. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedFirewallFeature 22 } vmwNsxTDistributedFirewallDFWMemoryUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterHeapType, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: View the current DFW memory usage by invoking the NSX CLI command `get firewall thresholds` on the host. Consider re-balancing the workloads on this host to other hosts. " ::= { vmwNsxTDistributedFirewallFeature 3 } vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterHeapType, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedFirewallFeature 4 } vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterHeapType, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterDPUId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: View the current DFW memory usage by invoking the NSX CLI command `get firewall thresholds` on the DPU. Consider re-balancing the workloads on this host to other hosts. " ::= { vmwNsxTDistributedFirewallFeature 19 } vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterHeapType, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterDPUId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedFirewallFeature 20 } vmwNsxTDistributedFirewallDFWRulesLimitPerHostApproaching NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "The DFW rules limit for host vmwNsxTDataCenterTransportNodeName is approaching the maximum limit. Action required: Log in into the ESX host vmwNsxTDataCenterTransportNodeName and invoke the NSX CLI command `get firewall rule-stats total` to get the rule statistics for rules configured on the ESX host vmwNsxTDataCenterTransportNodeName. Reduce the number of rules configured for host vmwNsxTDataCenterTransportNodeName. Check the number of rules configured for various VIFs by using NSX CLI command `get firewall ruleset rules`. Reduce the number of rules configured for various VIFs. " ::= { vmwNsxTDistributedFirewallFeature 11 } vmwNsxTDistributedFirewallDFWRulesLimitPerHostApproachingClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "The DFW rules limit for host vmwNsxTDataCenterTransportNodeName dropped below the threshold. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedFirewallFeature 12 } vmwNsxTDistributedFirewallDFWRulesLimitPerHostExceeded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "The DFW rules limit for host vmwNsxTDataCenterTransportNodeName is about to exceed the maximum limit. Action required: Log in into the ESX host vmwNsxTDataCenterTransportNodeName and invoke the NSX CLI command `get firewall rule-stats total` to get the rule statistics for rules configured on the ESX host vmwNsxTDataCenterTransportNodeName. Reduce the number of rules configured for host vmwNsxTDataCenterTransportNodeName. Check the number of rules configured for various VIFs by using NSX CLI command `get firewall ruleset rules`. Reduce the number of rules configured for various VIFs. " ::= { vmwNsxTDistributedFirewallFeature 13 } vmwNsxTDistributedFirewallDFWRulesLimitPerHostExceededClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "The DFW rules limit for host vmwNsxTDataCenterTransportNodeName dropped below maximum limit. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedFirewallFeature 14 } vmwNsxTDistributedFirewallDFWRulesLimitPervNICApproaching NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "The DFW rules limit for VIF vmwNsxTDataCenterEntityId on destination host vmwNsxTDataCenterTransportNodeName is approaching the maximum limit. Action required: Log in into the ESX host vmwNsxTDataCenterTransportNodeName and invoke the NSX CLI command `get firewall ruleset rules` to get the rule statistics for rules configured on the corresponding VIF. Reduce the number of rules configured for VIF vmwNsxTDataCenterEntityId. " ::= { vmwNsxTDistributedFirewallFeature 15 } vmwNsxTDistributedFirewallDFWRulesLimitPervNICApproachingClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "The DFW rules limit for VIF vmwNsxTDataCenterEntityId on the destination host vmwNsxTDataCenterTransportNodeName dropped below the threshold. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedFirewallFeature 16 } vmwNsxTDistributedFirewallDFWRulesLimitPervNICExceeded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "The DFW rules limit for VIF vmwNsxTDataCenterEntityId on destination host vmwNsxTDataCenterTransportNodeName is about to exceed the maximum limit. Action required: Log in into the ESX host vmwNsxTDataCenterTransportNodeName and invoke the NSX CLI command `get firewall ruleset rules` to get the rule statistics for rules configured on the corresponding VIF. Reduce the number of rules configured for VIF vmwNsxTDataCenterEntityId. " ::= { vmwNsxTDistributedFirewallFeature 9 } vmwNsxTDistributedFirewallDFWRulesLimitPervNICExceededClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "The DFW rules limit for VIF vmwNsxTDataCenterEntityId on the destination host vmwNsxTDataCenterTransportNodeName dropped below maximum limit. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedFirewallFeature 10 } vmwNsxTDistributedFirewallDFWSessionCountHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The DFW session count is high on Transport node vmwNsxTDataCenterEntityId, it has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review the network traffic load level of the workloads on the host. Consider re-balancing the workloads on this host to other hosts. " ::= { vmwNsxTDistributedFirewallFeature 5 } vmwNsxTDistributedFirewallDFWSessionCountHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The DFW session count on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the the threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedFirewallFeature 6 } vmwNsxTDistributedFirewallDFWVmotionFailure NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "The DFW vMotion for DFW filter vmwNsxTDataCenterEntityId on destination host vmwNsxTDataCenterTransportNodeName has failed and the port for the entity has been disconnected. Action required: Check VMs on the host in NSX Manager, manually repush the DFW configuration through NSX Manager UI. The DFW policy to be repushed can be traced by the DFW filter vmwNsxTDataCenterEntityId. Also consider finding the VM to which the DFW filter is attached and restart it. " ::= { vmwNsxTDistributedFirewallFeature 7 } vmwNsxTDistributedFirewallDFWVmotionFailureClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "The DFW configuration for DFW filter vmwNsxTDataCenterEntityId on the destination host vmwNsxTDataCenterTransportNodeName has succeeded and error caused by DFW vMotion failure cleared. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedFirewallFeature 8 } -- ********************************************************** -- DistributedIDSIPS feature event notifications -- ********************************************************** vmwNsxTDistributedIDSIPSFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the DistributedIDSIPS feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 33 } vmwNsxTDistributedIDSIPSFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for DistributedIDSIPS feature notifications. " ::= { vmwNsxTDistributedIDSIPSFeaturePrefix 0 } vmwNsxTDistributedIDSIPSIDPSBypassedCPUOversubscribed NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The IDPS engine has insufficient CPU resources and is unable to keep pace with the incoming traffic resulting in the excess traffic being bypassed. For more details, login to the ESX host and issue the following command: `vsipioctl getdpiinfo -s` and look at oversubscription stats. Action required: Review reason for oversubscription. Move certain applications to different host. " ::= { vmwNsxTDistributedIDSIPSFeature 53 } vmwNsxTDistributedIDSIPSIDPSBypassedCPUOversubscribedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The distributed IDPS engine has adequate CPU resources and is not bypassing any traffic. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 54 } vmwNsxTDistributedIDSIPSIDPSBypassedNetworkOversubscribed NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The IDPS engine is unable to keep pace with the rate of incoming traffic resulting in the excess traffic being bypassed. For more details, login to the ESX host and issue the following command: `vsipioctl getdpiinfo -s` and look at oversubscription stats. Action required: Review reason for oversubscription. Review the IDPS rules to reduce the amount of traffic being subject to IDPS service. " ::= { vmwNsxTDistributedIDSIPSFeature 55 } vmwNsxTDistributedIDSIPSIDPSBypassedNetworkOversubscribedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The distributed IDPS engine is not bypassing any traffic. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 56 } vmwNsxTDistributedIDSIPSIDPSEngineCPUOversubscriptionHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "CPU utilization for the distributed IDPS engine is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review reason for oversubscription. Move certain applications to different host. " ::= { vmwNsxTDistributedIDSIPSFeature 57 } vmwNsxTDistributedIDSIPSIDPSEngineCPUOversubscriptionHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "CPU utilization for the distributed IDPS engine is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 58 } vmwNsxTDistributedIDSIPSIDPSCPUOversubscriptionVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "CPU utilization for the distributed IDPS engine is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review reason for oversubscription. Move certain applications to different host. " ::= { vmwNsxTDistributedIDSIPSFeature 59 } vmwNsxTDistributedIDSIPSIDPSCPUOversubscriptionVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "CPU utilization for the distributed IDPS engine is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 60 } vmwNsxTDistributedIDSIPSIDPSDroppedCPUOversubscribed NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The IDPS engine has insufficient CPU resources and is unable to keep pace with the incoming traffic resulting in the excess traffic being dropped. For more details, login to the ESX host and issue the following command: `vsipioctl getdpiinfo -s` and look at oversubscription stats. Action required: Review reason for oversubscription. Move certain applications to different host. " ::= { vmwNsxTDistributedIDSIPSFeature 61 } vmwNsxTDistributedIDSIPSIDPSDroppedCPUOversubscribedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The distributed IDPS engine has adequate CPU resources and is not dropping any traffic. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 62 } vmwNsxTDistributedIDSIPSIDPSDroppedNetworkOversubscribed NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The IDPS engine is unable to keep pace with the rate of incoming traffic resulting in the excess traffic being dropped. For more details, login to the ESX host and issue the following command: `vsipioctl getdpiinfo -s` and look at oversubscription stats. Action required: Review reason for oversubscription. Review the IDPS rules to reduce the amount of traffic being subject to IDPS service. " ::= { vmwNsxTDistributedIDSIPSFeature 63 } vmwNsxTDistributedIDSIPSIDPSDroppedNetworkOversubscribedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The distributed IDPS engine is not dropping any traffic. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 64 } vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Network utilization for the distributed IDPS engine is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review reason for oversubscription. Review the IDPS rules to reduce the amount of traffic being subject to IDPS service. " ::= { vmwNsxTDistributedIDSIPSFeature 65 } vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Network utilization for the distributed IDPS engine is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 66 } vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Network utilization for the distributed IDPS engine is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review reason for oversubscription. Review the IDPS rules to reduce the amount of traffic being subject to IDPS service. " ::= { vmwNsxTDistributedIDSIPSFeature 67 } vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Network utilization for the distributed IDPS engine is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 68 } vmwNsxTDistributedIDSIPSMaxEventsReached NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIDSEventsCount, vmwNsxTDataCenterMaxIDSEventsAllowed } STATUS current DESCRIPTION "The number of intrusion events in the system is vmwNsxTDataCenterIDSEventsCount which is higher than the maximum allowed value vmwNsxTDataCenterMaxIDSEventsAllowed. Action required: There is no manual intervention required. A purge job will kick in automatically every 3 minutes and delete 10% of the older records to bring the total intrusion events count in the system to below the threshold value of 1.5 million events. " ::= { vmwNsxTDistributedIDSIPSFeature 3 } vmwNsxTDistributedIDSIPSMaxEventsReachedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIDSEventsCount, vmwNsxTDataCenterMaxIDSEventsAllowed } STATUS current DESCRIPTION "The number of intrusion events in the system is vmwNsxTDataCenterIDSEventsCount which is below the maximum allowed value vmwNsxTDataCenterMaxIDSEventsAllowed. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 4 } vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine CPU usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the high threshold value of 75%. Action required: Consider re-balancing the VM workloads on this host to other hosts. " ::= { vmwNsxTDistributedIDSIPSFeature 7 } vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine CPU usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is below the high threshold value of 75%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 8 } vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine CPU usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the medium high threshold value of 85%. Action required: Consider re-balancing the VM workloads on this host to other hosts. " ::= { vmwNsxTDistributedIDSIPSFeature 21 } vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine CPU usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is below the medium high threshold value of 85%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 22 } vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine CPU usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the very high threshold value of 95%. Action required: Consider re-balancing the VM workloads on this host to other hosts. " ::= { vmwNsxTDistributedIDSIPSFeature 9 } vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine CPU usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is below the very high threshold value of 95%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 10 } vmwNsxTDistributedIDSIPSNSXIDPSEngineDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "NSX IDPS is enabled via NSX policy and IDPS rules are configured, but NSX-IDPS engine is down. Action required: 1. Check /var/log/nsx-syslog.log to see if there are errors reported. 2. Invoke the NSX CLI command `get ids engine status` to check if NSX Distributed IDPS is in disabled state. If so, invoke `/etc/init.d/nsx-idps start` to start the service. 3. Invoke `/etc/init.d/nsx-vdpi status` to check if nsx-vdpi is running. If not, invoke `/etc/init.d/nsx-vdpi start` to start the service. " ::= { vmwNsxTDistributedIDSIPSFeature 13 } vmwNsxTDistributedIDSIPSNSXIDPSEngineDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "NSX IDPS is in one of the cases below. 1. NSX IDPS is disabled via NSX policy. 2. NSX IDPS engine is enabled, NSX-IDPS engine and vdpi are up, and NSX IDPS has been enabled and IDPS rules are configured via NSX Policy. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 14 } vmwNsxTDistributedIDSIPSNSXIDPSEngineDownOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "NSX IDPS is enabled via NSX policy and IDPS rules are configured, but NSX-IDPS engine is down on DPU vmwNsxTDataCenterDPUId. Action required: 1. Check /var/log/nsx-idps/nsx-idps.log and /var/log/nsx-syslog.log to see if there are errors reported. 2. Invoke the NSX CLI command `get ids engine status` to check if NSX Distributed IDPS is in disabled state. If so, invoke `/etc/init.d/nsx-idps start` to start the service. 3. Invoke `/etc/init.d/nsx-vdpi status` to check if nsx-vdpi is running. If not, invoke `/etc/init.d/nsx-vdpi start` to start the service. " ::= { vmwNsxTDistributedIDSIPSFeature 31 } vmwNsxTDistributedIDSIPSNSXIDPSEngineDownOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "NSX IDPS is in one of the cases below on DPU vmwNsxTDataCenterDPUId. 1. NSX IDPS is disabled via NSX policy. 2. NSX IDPS engine is enabled, NSX-IDPS engine and vdpi are up, and NSX IDPS has been enabled and IDPS rules are configured via NSX Policy. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 32 } vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the high threshold value of 75%. Action required: Consider re-balancing the VM workloads on this host to other hosts. " ::= { vmwNsxTDistributedIDSIPSFeature 15 } vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is below the high threshold value of 75%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 16 } vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "NSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the high threshold value of 75% on DPU vmwNsxTDataCenterDPUId. Action required: Consider re-balancing the VM workloads on this host to other hosts. " ::= { vmwNsxTDistributedIDSIPSFeature 23 } vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine memory usage has reached on DPU vmwNsxTDataCenterDPUId, vmwNsxTDataCenterSystemResourceUsage%, which is below the high threshold value of 75%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 24 } vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the medium high threshold value of 85%. Action required: Consider re-balancing the VM workloads on this host to other hosts. " ::= { vmwNsxTDistributedIDSIPSFeature 17 } vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is below the medium high threshold value of 85%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 18 } vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageMedHighOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "NSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the medium high threshold value of 85% on DPU vmwNsxTDataCenterDPUId. Action required: Consider re-balancing the VM workloads on this host to other hosts. " ::= { vmwNsxTDistributedIDSIPSFeature 33 } vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageMedHighOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine memory usage has reached on DPU vmwNsxTDataCenterDPUId, vmwNsxTDataCenterSystemResourceUsage%, which is below the medium high threshold value of 85%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 34 } vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the very high threshold value of 95%. Action required: Consider re-balancing the VM workloads on this host to other hosts. " ::= { vmwNsxTDistributedIDSIPSFeature 19 } vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is below the very high threshold value of 95%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 20 } vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageVeryHighDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "NSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the very high threshold value of 95% on DPU vmwNsxTDataCenterDPUId. Action required: Consider re-balancing the VM workloads on this host to other hosts. " ::= { vmwNsxTDistributedIDSIPSFeature 35 } vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageVeryHighDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId, vmwNsxTDataCenterSystemResourceUsage } STATUS current DESCRIPTION "NSX-IDPS engine memory usage has reached on DPU vmwNsxTDataCenterDPUId, vmwNsxTDataCenterSystemResourceUsage%, which is below the very high threshold value of 95%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDistributedIDSIPSFeature 36 } -- ********************************************************** -- DNS feature event notifications -- ********************************************************** vmwNsxTDNSFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the DNS feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 30 } vmwNsxTDNSFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for DNS feature notifications. " ::= { vmwNsxTDNSFeaturePrefix 0 } vmwNsxTDNSForwarderDisabled NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "DNS forwarder vmwNsxTDataCenterEntityId is disabled. Action required: 1. Invoke the NSX CLI command `get dns-forwarders status` to verify if the DNS forwarder is in the disabled state. 2. Use NSX Policy API or Manager API to enable the DNS forwarder it should not be in the disabled state. " ::= { vmwNsxTDNSFeature 1 } vmwNsxTDNSForwarderDisabledClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "DNS forwarder vmwNsxTDataCenterEntityId is enabled. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDNSFeature 2 } vmwNsxTDNSForwarderDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "DNS forwarder vmwNsxTDataCenterEntityId is not running. This is impacting the identified DNS Forwarder that is currently enabled. Action required: 1. Invoke the NSX CLI command `get dns-forwarders status` to verify if the DNS forwarder is in down state. 2. Check /var/log/syslog to see if there are errors reported. 3. Collect a support bundle and contact the NSX support team. " ::= { vmwNsxTDNSFeature 3 } vmwNsxTDNSForwarderDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "DNS forwarder vmwNsxTDataCenterEntityId is running again. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDNSFeature 4 } vmwNsxTDNSForwarderUpstreamServerTimeout NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntentPath, vmwNsxTDataCenterDNSId, vmwNsxTDataCenterDNSUpstreamIP } STATUS current DESCRIPTION "DNS forwarder vmwNsxTDataCenterIntentPath(vmwNsxTDataCenterDNSId) did not receive a timely response from upstream server vmwNsxTDataCenterDNSUpstreamIP. Compute instance connectivity to timed out FQDNs may be impacted. Action required: 1. Invoke the NSX API GET /api/v1/dns/forwarders/vmwNsxTDataCenterDNSId/nslookup? address=
&server_ip=vmwNsxTDataCenterDNSUpstreamIP&source_ip=. This API request triggers a DNS lookup to the upstream server in the DNS forwarder's network namespace.
is the IP address or FQDN in the same domain as the upstream server. is an IP address in the upstream server's zone. If the API returns a connection timed out response, there is likely a network error or upstream server problem. Check why DSN lookups are not reaching the upstream server or why the upstream server is not returning a response. If the API response indicates the upstream server is answering, proceed to step 2. 2. Invoke the NSX API GET /api/v1/dns/forwarders/vmwNsxTDataCenterDNSId/nslookup? address=
. This API request triggers a DNS lookup to the DNS forwarder. If the API returns a valid response, the upstream server may have recovered and this alarm should get resolved within a few minutes. If the API returns a connection timed out response, proceed to step 3. 3. Invoke the NSX CLI command `get dns-forwarder vmwNsxTDataCenterDNSId live-debug server-ip vmwNsxTDataCenterDNSUpstreamIP`. This command triggers live debugging on the upstream server and logs details and statistics showing why the DNS forwarder is not getting a response. " ::= { vmwNsxTDNSFeature 5 } vmwNsxTDNSForwarderUpstreamServerTimeoutClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntentPath, vmwNsxTDataCenterDNSId, vmwNsxTDataCenterDNSUpstreamIP } STATUS current DESCRIPTION "DNS forwarder vmwNsxTDataCenterIntentPath(vmwNsxTDataCenterDNSId) upstream server vmwNsxTDataCenterDNSUpstreamIP is normal. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTDNSFeature 6 } -- ********************************************************** -- Edge feature event notifications -- ********************************************************** vmwNsxTEdgeFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the Edge feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 45 } vmwNsxTEdgeFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for Edge feature notifications. " ::= { vmwNsxTEdgeFeaturePrefix 0 } vmwNsxTEdgeEdgeHardwareVersionMismatch NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterEdgeClusterName, vmwNsxTDataCenterEdgeTNHwVersion, vmwNsxTDataCenterEdgeClusterHighestHwVersion } STATUS current DESCRIPTION "The Edge node vmwNsxTDataCenterTransportNodeName in Edge cluster vmwNsxTDataCenterEdgeClusterName has a hardware version vmwNsxTDataCenterEdgeTNHwVersion, which is less than the highest hardware version vmwNsxTDataCenterEdgeClusterHighestHwVersion in the Edge cluster. Action required: Follow KB article to resolve hardware version mismatch alarm for Edge node vmwNsxTDataCenterTransportNodeName. For more information see: https://www.vmware.com/esx/support/askvmware/index.php?eventtype=edge.edge_hardware_version_mismatch " ::= { vmwNsxTEdgeFeature 15 } vmwNsxTEdgeEdgeHardwareVersionMismatchClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "The Edge node vmwNsxTDataCenterTransportNodeName hardware version mismatch is resolved now. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeFeature 16 } vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChanged NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason } STATUS current DESCRIPTION "The Edge node vmwNsxTDataCenterEntityId settings and vSphere configuration are changed and does not match the policy intent configuration. The Edge node configuration visible to user on UI or API is not same as what is realized. The realized Edge node changes made by user outside of NSX Manager are shown in the details of this alarm and any edits in UI or API will overwrite the realized configuration. Fields that differ for Edge node settings and vSphere configuration are listed in runtime data vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason Action required: Review the node settings and vSphere configuration of this Edge Transport Node vmwNsxTDataCenterEntityId. Follow one of following actions to resolve alarm - 1. Manually update Edge Transport Node setting Policy intent using API : PUT https:///api/v1/transport-nodes/. 2. Accept intent or vSphere realized Edge node configuration or realized Edge node settings for this Edge Transport Node through Edge Transport Node resolver to resolve this alarm. 3. Resolve alarm by accepting the Edge node settings and vSphere realized configuration using refresh API - POST https:///api/v1/transport-nodes/?action=refresh_node_configuration&resource_type=EdgeNode. " ::= { vmwNsxTEdgeFeature 1 } vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChangedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Edge node vmwNsxTDataCenterEntityId node settings and vSphere settings are consistent with policy intent now. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeFeature 2 } vmwNsxTEdgeEdgeNodeSettingsMismatch NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeNodeSettingMismatchReason } STATUS current DESCRIPTION "The Edge node vmwNsxTDataCenterEntityId settings configuration does not match the policy intent configuration. The Edge node configuration visible to user on UI or API is not same as what is realized. The realized Edge node changes made by user outside of NSX Manager are shown in the details of this alarm and any edits in UI or API will overwrite the realized configuration. Fields that differ for the Edge node are listed in runtime data vmwNsxTDataCenterEdgeNodeSettingMismatchReason Action required: Review the node settings of this Edge transport node vmwNsxTDataCenterEntityId. Follow one of following actions to resolve alarm - 1. Manually update Edge transport node setting Policy intent using API - PUT https:///api/v1/transport-nodes/. 2. Accept intent or realized Edge node settings for this Edge transport node through Edge transport node resolver to resolve this alarm. 3. Resolve alarm by accepting the Edge node settings configuration using refresh API - POST https:///api/v1/transport-nodes/?action=refresh_node_configuration&resource_type=EdgeNode. " ::= { vmwNsxTEdgeFeature 3 } vmwNsxTEdgeEdgeNodeSettingsMismatchClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Edge node vmwNsxTDataCenterEntityId node settings are consistent with policy intent now. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeFeature 4 } vmwNsxTEdgeEdgeVMNotPresentInBothNSXInventoryAndvCenter NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterPolicyEdgeVMName, vmwNsxTDataCenterVMMorefId } STATUS current DESCRIPTION "The VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId corresponding to the Edge Transport node vmwNsxTDataCenterEntityId vSphere placement parameters is not found in both NSX inventory and vCenter. The placement parameters in the vSphere configuration of this Edge Transport node vmwNsxTDataCenterEntityId refer to the VM with moref vmwNsxTDataCenterVMMorefId. Action required: The managed object reference moref id of a VM has the form vm-number, which is visible in the URL on selecting the Edge VM in vCenter UI. Example vm-12011 in https:///ui/app/vm;nav=h/urn:vmomi:VirtualMachine:vm-12011:164ff798-c4f1-495b-a0be-adfba337e5d2/summary Find the VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId in vCenter for this Edge Transport Node vmwNsxTDataCenterEntityId. Follow the below action to resolve the alarm - Check if VM has been deleted in vSphere or is present with a different moref id. 1. If the VM is still present in vCenter, put the Edge Transport node in maintenance mode and then power off and delete the Edge VM in vCenter. Use the NSX Redeploy API to deploy a new VM for the Edge node. Data traffic for the Edge Transport node will be disrupted in the interim duration if the Edge VM is forwarding traffic. 2. If the VM is not present in vCenter, use the redeploy API to deploy a new VM for the Edge node. POST https:///api/v1/transport-nodes/?action=redeploy. " ::= { vmwNsxTEdgeFeature 11 } vmwNsxTEdgeEdgeVMNotPresentInBothNSXInventoryAndvCenterClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVMMorefId } STATUS current DESCRIPTION "Edge node vmwNsxTDataCenterEntityId with VM moref id vmwNsxTDataCenterVMMorefId is present in both NSX inventory and vCenter. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeFeature 12 } vmwNsxTEdgeEdgeVMPresentInNSXInventoryNotPresentInvCenter NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterPolicyEdgeVMName, vmwNsxTDataCenterVMMorefId } STATUS current DESCRIPTION "The VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId corresponding to the Edge Transport node vmwNsxTDataCenterEntityId vSphere placement parameters is found in NSX inventory but is not present in vCenter. Check if the VM has been removed in vCenter or is present with a different VM moref id. Action required: The managed object reference moref id of a VM has the form vm-number, which is visible in the URL on selecting the Edge VM in vCenter UI. Example vm-12011 in https:///ui/app/vm;nav=h/urn:vmomi:VirtualMachine:vm-12011:164ff798-c4f1-495b-a0be-adfba337e5d2/summary Find the VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId in vCenter for this Edge Transport Node vmwNsxTDataCenterEntityId. If the Edge VM is present in vCenter with a different moref id, follow the below action. Use NSX add or update placement API with JSON request payload properties vm_id and vm_deployment_config to update the new vm moref id and vSphere deployment parameters. POST https:///api/v1/transport-nodes/?action=addOrUpdatePlacementReferences. If the Edge VM with name vmwNsxTDataCenterPolicyEdgeVMName is not present in vCenter, use the NSX Redeploy API to deploy a new VM for the Edge node. POST https:///api/v1/transport-nodes/?action=redeploy. " ::= { vmwNsxTEdgeFeature 9 } vmwNsxTEdgeEdgeVMPresentInNSXInventoryNotPresentInvCenterClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVMMorefId } STATUS current DESCRIPTION "Edge node vmwNsxTDataCenterEntityId with VM moref id vmwNsxTDataCenterVMMorefId is present in both NSX inventory and vCenter. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeFeature 10 } vmwNsxTEdgeEdgeVmvSphereSettingsMismatch NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason } STATUS current DESCRIPTION "The Edge node vmwNsxTDataCenterEntityId configuration on vSphere does not match the policy intent configuration. The Edge node configuration visible to user on UI or API is not same as what is realized. The realized Edge node changes made by user outside of NSX Manager are shown in the details of this alarm and any edits in UI or API will overwrite the realized configuration. Fields that differ for the Edge node are listed in runtime data vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason Action required: Review the vSphere configuration of this Edge Transport Node vmwNsxTDataCenterEntityId. Follow one of following actions to resolve alarm - 1. Accept intent or vSphere realized Edge node configuration for this Edge Transport Node through Edge Transport Node resolver to resolve this alarm. 2. Resolve alarm by accepting the Edge node vSphere realized configuration using refresh API - POST https:///api/v1/transport-nodes/?action=refresh_node_configuration&resource_type=EdgeNode. " ::= { vmwNsxTEdgeFeature 5 } vmwNsxTEdgeEdgeVmvSphereSettingsMismatchClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Edge node vmwNsxTDataCenterEntityId VM vSphere settings are consistent with policy intent now. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeFeature 6 } vmwNsxTEdgeEdgevSphereLocationMismatch NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgevSphereLocationMismatchReason } STATUS current DESCRIPTION "The Edge node vmwNsxTDataCenterEntityId has been moved using vMotion. The Edge node vmwNsxTDataCenterEntityId, the configuration on vSphere does not match the policy intent configuration. The Edge node configuration visible to user on UI or API is not same as what is realized. The realized Edge node changes made by user outside of NSX Manager are shown in the details of this alarm. Fields that differ for the Edge node are listed in runtime data vmwNsxTDataCenterEdgevSphereLocationMismatchReason Action required: Review the vSphere configuration of this Edge Transport Node vmwNsxTDataCenterEntityId. Follow one of following actions to resolve alarm - 1. Resolve alarm by accepting the Edge node vSphere realized config using refresh API - POST https:///api/v1/transport-nodes/?action=refresh_node_configuration&resource_type=EdgeNode. 2. If you want to return to the previous location use NSX Redeploy API - POST https:///api/v1/transport-nodes/?action=redeploy. vMotion back to the original host is not supported. " ::= { vmwNsxTEdgeFeature 7 } vmwNsxTEdgeEdgevSphereLocationMismatchClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Edge node vmwNsxTDataCenterEntityId node vSphere settings are consistent with policy intent now. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeFeature 8 } vmwNsxTEdgeFailedToDeleteTheOldVMInvCenterDuringRedeploy NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVMMorefId, vmwNsxTDataCenterNewVMMorefId, vmwNsxTDataCenterPolicyEdgeVMName } STATUS current DESCRIPTION "Failed to power off and delete the Edge node vmwNsxTDataCenterEntityId VM with moref id vmwNsxTDataCenterVMMorefId in vCenter during Redeploy operation. A new Edge VM with moref id vmwNsxTDataCenterNewVMMorefId has been deployed. Both old and new VMs for this Edge are functional at the same time and may result in IP conflicts and networking issues. Action required: The managed object reference moref id of a VM has the form vm-number, which is visible in the URL on selecting the Edge VM in vCenter UI. Example vm-12011 in https:///ui/app/vm;nav=h/urn:vmomi:VirtualMachine:vm-12011:164ff798-c4f1-495b-a0be-adfba337e5d2/summary Find the VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId in vCenter for this Edge Transport Node vmwNsxTDataCenterEntityId. Power off and delete the old Edge VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId in vCenter. " ::= { vmwNsxTEdgeFeature 13 } vmwNsxTEdgeFailedToDeleteTheOldVMInvCenterDuringRedeployClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVMMorefId, vmwNsxTDataCenterNewVMMorefId } STATUS current DESCRIPTION "Edge node vmwNsxTDataCenterEntityId with stale VM moref id vmwNsxTDataCenterVMMorefId is not found anymore in both NSX inventory and vCenter. New deployed VM with moref id vmwNsxTDataCenterNewVMMorefId is present in both NSX inventory and vCenter. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeFeature 14 } -- ********************************************************** -- EdgeCluster feature event notifications -- ********************************************************** vmwNsxTEdgeClusterFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the EdgeCluster feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 49 } vmwNsxTEdgeClusterFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for EdgeCluster feature notifications. " ::= { vmwNsxTEdgeClusterFeaturePrefix 0 } vmwNsxTEdgeClusterEdgeClusterMemberRelocateFailure NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeClusterId, vmwNsxTDataCenterMemberIndexId, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "The operation on Edge cluster vmwNsxTDataCenterEdgeClusterId to relocate all service context failed for Edge cluster member index vmwNsxTDataCenterMemberIndexId with Transport node ID vmwNsxTDataCenterTransportNodeId Action required: Review the available capacity for the Edge cluster. If more capacity is required, scale your Edge cluster. Retry the relocate Edge cluster member operation. " ::= { vmwNsxTEdgeClusterFeature 5 } vmwNsxTEdgeClusterEdgeClusterMemberRelocateFailureClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "Edge node with vmwNsxTDataCenterTransportNodeId relocation failure has been resolved now. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeClusterFeature 6 } -- ********************************************************** -- EdgeHealth feature event notifications -- ********************************************************** vmwNsxTEdgeHealthFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the EdgeHealth feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 2 } vmwNsxTEdgeHealthFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for EdgeHealth feature notifications. " ::= { vmwNsxTEdgeHealthFeaturePrefix 0 } vmwNsxTEdgeHealthDatapathThreadDeadlocked NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeThreadName } STATUS current DESCRIPTION "Edge node datapath thread vmwNsxTDataCenterEdgeThreadName is deadlocked. Action required: Restart the dataplane service by invoking the NSX CLI command `restart service dataplane`. " ::= { vmwNsxTEdgeHealthFeature 45 } vmwNsxTEdgeHealthDatapathThreadDeadlockedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeThreadName } STATUS current DESCRIPTION "Edge node datapath thread vmwNsxTDataCenterEdgeThreadName is free from deadlock. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 46 } vmwNsxTEdgeHealthEdgeCPUUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review the configuration, running services and sizing of this Edge node. Consider adjusting the Edge appliance form factor size or rebalancing services to other Edge nodes for the applicable workload. " ::= { vmwNsxTEdgeHealthFeature 1 } vmwNsxTEdgeHealthEdgeCPUUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 2 } vmwNsxTEdgeHealthEdgeCPUUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review the configuration, running services and sizing of this Edge node. Consider adjusting the Edge appliance form factor size or rebalancing services to other Edge nodes for the applicable workload. " ::= { vmwNsxTEdgeHealthFeature 3 } vmwNsxTEdgeHealthEdgeCPUUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 4 } vmwNsxTEdgeHealthEdgeDatapathConfigurationFailure NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Failed to enable the datapath on the Edge node after three attempts. Action required: Ensure the Edge node's connectivity to the Manager node is healthy. From the Edge node's NSX CLI, invoke the command `get services` to check the health of services. If the dataplane service is stopped, invoke the command `start service dataplane` to start it. " ::= { vmwNsxTEdgeHealthFeature 21 } vmwNsxTEdgeHealthEdgeDatapathConfigurationFailureClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Datapath on the Edge node has been successfully enabled. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 22 } vmwNsxTEdgeHealthEdgeDatapathCPUHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDatapathResourceUsage } STATUS current DESCRIPTION "The datapath CPU usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterDatapathResourceUsage% which is at or above the high threshold for at least two minutes. Action required: Review the CPU statistics on the Edge node by invoking the NSX CLI command `get dataplane cpu stats` to show packet rates per CPU core. Higher CPU usage is expected with higher packet rates. Consider increasing the Edge appliance form factor size and rebalancing services on this Edge node to other Edge nodes in the same cluster or other Edge clusters. " ::= { vmwNsxTEdgeHealthFeature 17 } vmwNsxTEdgeHealthEdgeDatapathCPUHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached below the high threshold. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 18 } vmwNsxTEdgeHealthEdgeDatapathCPUVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDatapathResourceUsage } STATUS current DESCRIPTION "The datapath CPU usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterDatapathResourceUsage% which is at or above the very high threshold for at least two minutes. Action required: Review the CPU statistics on the Edge node by invoking the NSX CLI command `get dataplane cpu stats` to show packet rates per CPU core. Higher CPU usage is expected with higher packet rates. Consider increasing the Edge appliance form factor size and rebalancing services on this Edge node to other Edge nodes in the same cluster or other Edge clusters. " ::= { vmwNsxTEdgeHealthFeature 19 } vmwNsxTEdgeHealthEdgeDatapathCPUVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached below the very high threshold. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 20 } vmwNsxTEdgeHealthEdgeDatapathCryptodrvDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeCryptoDrvName } STATUS current DESCRIPTION "Edge node crypto driver vmwNsxTDataCenterEdgeCryptoDrvName is down. Action required: Upgrade the Edge node as needed. " ::= { vmwNsxTEdgeHealthFeature 23 } vmwNsxTEdgeHealthEdgeDatapathCryptodrvDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeCryptoDrvName } STATUS current DESCRIPTION "Edge node crypto driver vmwNsxTDataCenterEdgeCryptoDrvName is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 24 } vmwNsxTEdgeHealthEdgeDatapathMempoolHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterMempoolName, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The datapath mempool usage for vmwNsxTDataCenterMempoolName on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Log in as the root user and invoke the command `edge-appctl -t /var/run/vmware/edge/dpd.ctl mempool/show` and `edge-appctl -t /var/run/vmware/edge/dpd.ctl memory/show malloc_heap` to check DPDK memory usage. " ::= { vmwNsxTEdgeHealthFeature 25 } vmwNsxTEdgeHealthEdgeDatapathMempoolHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterMempoolName, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The datapath mempool usage for vmwNsxTDataCenterMempoolName on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 26 } vmwNsxTEdgeHealthEdgeDatapathNICThroughputHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeNICName, vmwNsxTDataCenterNICThroughput, vmwNsxTDataCenterNICThroughputThreshold } STATUS current DESCRIPTION "The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which is at or above the high threshold value of vmwNsxTDataCenterNICThroughputThreshold%. Action required: Examine the traffic thoughput levels on the NIC and determine whether configuration changes are needed. The 'get dataplane thoughput ' command can be used to monitor throughput. " ::= { vmwNsxTEdgeHealthFeature 49 } vmwNsxTEdgeHealthEdgeDatapathNICThroughputHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeNICName, vmwNsxTDataCenterNICThroughput, vmwNsxTDataCenterNICThroughputThreshold } STATUS current DESCRIPTION "The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which is below the high threshold value of vmwNsxTDataCenterNICThroughputThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 50 } vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeNICName, vmwNsxTDataCenterNICThroughput, vmwNsxTDataCenterNICThroughputThreshold } STATUS current DESCRIPTION "The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which is at or above the very high threshold value of vmwNsxTDataCenterNICThroughputThreshold%. Action required: Examine the traffic thoughput levels on the NIC and determine whether configuration changes are needed. The 'get dataplane thoughput ' command can be used to monitor throughput. " ::= { vmwNsxTEdgeHealthFeature 51 } vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeNICName, vmwNsxTDataCenterNICThroughput, vmwNsxTDataCenterNICThroughputThreshold } STATUS current DESCRIPTION "The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which is below the very high threshold value of vmwNsxTDataCenterNICThroughputThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 52 } vmwNsxTEdgeHealthEdgeDiskUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Examine the partition with high usage and see if there are any unexpected large files that can be removed. " ::= { vmwNsxTEdgeHealthFeature 9 } vmwNsxTEdgeHealthEdgeDiskUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 10 } vmwNsxTEdgeHealthEdgeDiskUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Examine the partition with high usage and see if there are any unexpected large files that can be removed. " ::= { vmwNsxTEdgeHealthFeature 11 } vmwNsxTEdgeHealthEdgeDiskUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 12 } vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDatapathResourceUsage } STATUS current DESCRIPTION "Global ARP table usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterDatapathResourceUsage% which is above the high threshold for over two minutes. Action required: Log in as the root user and invoke the command `edge-appctl -t /var/run/vmware/edge/dpd.ctl neigh/show` and check if neigh cache usage is normal. If it is normal, invoke the command `edge-appctl -t /var/run/vmware/edge/dpd.ctl neigh/set_param max_entries` to increase the ARP table size. " ::= { vmwNsxTEdgeHealthFeature 27 } vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Global ARP table usage on Edge node vmwNsxTDataCenterEntityId has reached below the high threshold. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 28 } vmwNsxTEdgeHealthEdgeMemoryUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review the configuration, running services and sizing of this Edge node. Consider adjusting the Edge appliance form factor size or rebalancing services to other Edge nodes for the applicable workload. " ::= { vmwNsxTEdgeHealthFeature 5 } vmwNsxTEdgeHealthEdgeMemoryUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 6 } vmwNsxTEdgeHealthEdgeMemoryUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review the configuration, running services and sizing of this Edge node. Consider adjusting the Edge appliance form factor size or rebalancing services to other Edge nodes for the applicable workload. " ::= { vmwNsxTEdgeHealthFeature 7 } vmwNsxTEdgeHealthEdgeMemoryUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 8 } vmwNsxTEdgeHealthEdgeNICLinkStatusDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeNICName } STATUS current DESCRIPTION "Edge node NIC vmwNsxTDataCenterEdgeNICName link is down. Action required: On the Edge node confirm if the NIC link is physically down by invoking the NSX CLI command `get interfaces`. If it is down, verify the cable connection. " ::= { vmwNsxTEdgeHealthFeature 29 } vmwNsxTEdgeHealthEdgeNICLinkStatusDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeNICName } STATUS current DESCRIPTION "Edge node NIC vmwNsxTDataCenterEdgeNICName link is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 30 } vmwNsxTEdgeHealthEdgeNICOutOfReceiveBuffer NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeNICName, vmwNsxTDataCenterRxRingBufferOverflowPercentage, vmwNsxTDataCenterRxMisses, vmwNsxTDataCenterRxProcessed } STATUS current DESCRIPTION "Edge NIC vmwNsxTDataCenterEdgeNICName receive ring buffer has overflowed by vmwNsxTDataCenterRxRingBufferOverflowPercentage% on Edge node vmwNsxTDataCenterEntityId. The missed packet count is vmwNsxTDataCenterRxMisses and processed packet count is vmwNsxTDataCenterRxProcessed. Action required: Run the NSX CLI command `get dataplane cpu stats` on the edge node and check: 1. If cpu usage is high, i.e., > 90%, then take a packet capture on the interface using the command `start capture interface direction input` or `start capture interface direction input core ` (to capture packets ingressing on specific core whose usage is high). Then analyze the capture to see if there are majority of fragmented packets or ipsec packets. If yes, then it is expected behavior. If not, datapath is probably busy with other operations. If this alarm lasts more than 2-3 minutes, contact VMware Support. 2. If cpu usage is not high, i.e., < 90%, then check if rx pps is high using the command `get dataplane cpu stats` (just to make sure the traffic rate is increasing). Then increase the ring size by 1024 using the command `set dataplane ring-size rx `. NOTE - The continuous increase of ring size by 1024 factor can lead to some performance issues. If even after increasing the ring size, the issue persists then it is an indication that edge needs a larger form factor deployment to accommodate the traffic. 3. If the alarm keeps on flapping i.e., triggers and resolves very soon, then it is due to bursty traffic. In this case check if rx pps as described above, if it is not high during the alarm active period then contact VMware Support. If pps is high it confirms bursty traffic. Consider suppressing the alarm. NOTE - There is no specific benchmark to decide what is regarded as a high pps value. It depends on infrastructure and type of traffic. The comparison can be made by noting down when alarm is inactive and when it is active. " ::= { vmwNsxTEdgeHealthFeature 31 } vmwNsxTEdgeHealthEdgeNICOutOfReceiveBufferClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeNICName } STATUS current DESCRIPTION "Edge NIC vmwNsxTDataCenterEdgeNICName receive ring buffer usage on Edge node vmwNsxTDataCenterEntityId is no longer overflowing. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 32 } vmwNsxTEdgeHealthEdgeNICOutOfTransmitBuffer NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeNICName, vmwNsxTDataCenterTxRingBufferOverflowPercentage, vmwNsxTDataCenterTxMisses, vmwNsxTDataCenterTxProcessed } STATUS current DESCRIPTION "Edge NIC vmwNsxTDataCenterEdgeNICName transmit ring buffer has overflowed by vmwNsxTDataCenterTxRingBufferOverflowPercentage% on Edge node vmwNsxTDataCenterEntityId. The missed packet count is vmwNsxTDataCenterTxMisses and processed packet count is vmwNsxTDataCenterTxProcessed. Action required: 1. If a lot of VMs are accommodated along with edge by the hypervisor then edge VM might not get time to run, hence the packets might not be retrieved by hypervisor. Then probably migrating the edge VM to a host with fewer VMs. 2. Increase the ring size by 1024 using the command `set dataplane ring-size tx `. If even after increasing the ring size, the issue persists then contact VMware Support as the ESX side transmit ring buffer might be of lower value. If there is no issue on ESX side, it indicates the edge needs to be scaled to a larger form factor deployment to accommodate the traffic. 3. If the alarm keeps on flapping, i.e., triggers and resolves very soon, then it is due to bursty traffic. In this case check if tx pps using the command `get dataplane cpu stats`. If it is not high during the alarm active period then contact VMware Support. If pps is high it confirms bursty traffic. Consider suppressing the alarm. NOTE - There is no specific benchmark to decide what is regarded as a high pps value. It depends on infrastructure and type of traffic. The comparison can be made by noting down when alarm is inactive and when it is active. " ::= { vmwNsxTEdgeHealthFeature 33 } vmwNsxTEdgeHealthEdgeNICOutOfTransmitBufferClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeNICName } STATUS current DESCRIPTION "Edge NIC vmwNsxTDataCenterEdgeNICName transmit ring buffer usage on Edge node vmwNsxTDataCenterEntityId is no longer overflowing. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 34 } vmwNsxTEdgeHealthFailureDomainDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "All members of failure domain vmwNsxTDataCenterTransportNodeId are down. Action required: 1. On the Edge node identified by vmwNsxTDataCenterTransportNodeId, check the connectivity to the management and control planes by invoking the NSX CLI command `get managers` and `get controllers`. 2. Invoke the NSX CLI command `get interface eth0` to check the management interface status. 3. Invoke the CLI `get services` to check the core services status like dataplane/local-controller/nestdb/router, etc. 4. Inspect the /var/log/syslog to find the suspecting error. 5. Reboot the Edge node. " ::= { vmwNsxTEdgeHealthFeature 53 } vmwNsxTEdgeHealthFailureDomainDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "All members of failure domain vmwNsxTDataCenterTransportNodeId are reachable. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 54 } vmwNsxTEdgeHealthMegaFlowCacheHitRateLow NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFlowCacheThreshold, vmwNsxTDataCenterCoreId } STATUS current DESCRIPTION "Mega Flow Cache hit rate on Edge node vmwNsxTDataCenterEntityId has decreased below the specified threshold of vmwNsxTDataCenterFlowCacheThreshold% for core vmwNsxTDataCenterCoreId, and the Datapath CPU usage has increased for the last 30 minutes. Action required: The Cache Flow hit rate has decreased for the last 30 minutes which is an indication that there may be degradation on Edge performance. The traffic will continue to be forwarded and you may not experience any issues. Check the datapath CPU utilization for Edge vmwNsxTDataCenterEntityId core vmwNsxTDataCenterCoreId if it is high for the last 30 minutes. The Edge will have low flow-cache hit rate when there are continuously new flows getting created because the first packet of any new flow will be used to setup to flow-cache for fast path processing. You may want to increase your Edge appliance size or increase the number of Edge nodes used for Active/Active Gateways. " ::= { vmwNsxTEdgeHealthFeature 55 } vmwNsxTEdgeHealthMegaFlowCacheHitRateLowClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Flow Cache hit rate is in the normal range. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 56 } vmwNsxTEdgeHealthMicroFlowCacheHitRateLow NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFlowCacheThreshold, vmwNsxTDataCenterCoreId } STATUS current DESCRIPTION "Micro Flow Cache hit rate on Edge node vmwNsxTDataCenterEntityId has decreased below the specified threshold of vmwNsxTDataCenterFlowCacheThreshold% for core vmwNsxTDataCenterCoreId, and the Datapath CPU usage has increased for the last 30 minutes. Action required: The Cache Flow hit rate has decreased for the last 30 minutes which is an indication that there may be degradation on Edge performance. The traffic will continue to be forwarded and you may not experience any issues. Check the datapath CPU utilization for Edge vmwNsxTDataCenterEntityId core vmwNsxTDataCenterCoreId if it is high for the last 30 minutes. The Edge will have low flow-cache hit rate when there are continuously new flows getting created because the first packet of any new flow will be used to setup to flow-cache for fast path processing. You may want to increase your Edge appliance size or increase the number of Edge nodes used for Active/Active Gateways. " ::= { vmwNsxTEdgeHealthFeature 57 } vmwNsxTEdgeHealthMicroFlowCacheHitRateLowClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Flow Cache hit rate is in the normal range. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 58 } vmwNsxTEdgeHealthStorageError NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName } STATUS current DESCRIPTION "The following disk partitions on the Edge node are in read-only mode: vmwNsxTDataCenterDiskPartitionName Action required: Examine the read-only partition to see if reboot resolves the issue or the disk needs to be replaced. Contact GSS for more information. " ::= { vmwNsxTEdgeHealthFeature 37 } vmwNsxTEdgeHealthStorageErrorClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName } STATUS current DESCRIPTION "The following disk partitions on the Edge node have recovered from read-only mode: vmwNsxTDataCenterDiskPartitionName Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEdgeHealthFeature 38 } -- ********************************************************** -- EndpointProtection feature event notifications -- ********************************************************** vmwNsxTEndpointProtectionFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the EndpointProtection feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 13 } vmwNsxTEndpointProtectionFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for EndpointProtection feature notifications. " ::= { vmwNsxTEndpointProtectionFeaturePrefix 0 } vmwNsxTEndpointProtectionEAMStatusDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "ESX Agent Manager (EAM) service on compute manager vmwNsxTDataCenterEntityId is down. Action required: Start the ESX Agent Manager (EAM) service. SSH into vCenter and invoke the command `service vmware-eam start`. " ::= { vmwNsxTEndpointProtectionFeature 1 } vmwNsxTEndpointProtectionEAMStatusDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "ESX Agent Manager (EAM) service on compute manager vmwNsxTDataCenterEntityId is either up or compute manager vmwNsxTDataCenterEntityId has been removed. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEndpointProtectionFeature 2 } vmwNsxTEndpointProtectionPartnerChannelDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The connection between host module and Partner SVM vmwNsxTDataCenterEntityId is down. Action required: Refer to https://kb.vmware.com/s/article/85844 and make sure that Partner SVM vmwNsxTDataCenterEntityId is re-connected to the host module. " ::= { vmwNsxTEndpointProtectionFeature 3 } vmwNsxTEndpointProtectionPartnerChannelDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The connection between host module and Partner SVM vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTEndpointProtectionFeature 4 } -- ********************************************************** -- Federation feature event notifications -- ********************************************************** vmwNsxTFederationFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the Federation feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 32 } vmwNsxTFederationFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for Federation feature notifications. " ::= { vmwNsxTFederationFeaturePrefix 0 } vmwNsxTFederationGMToGMLatencyWarning NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFromGMPath, vmwNsxTDataCenterToGMPath, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteId } STATUS current DESCRIPTION "Latency is higher than expected between Global Managers vmwNsxTDataCenterFromGMPath and vmwNsxTDataCenterToGMPath. Action required: Check the connectivity from Global Manager vmwNsxTDataCenterFromGMPath(vmwNsxTDataCenterSiteId) to the Global Manager vmwNsxTDataCenterToGMPath(vmwNsxTDataCenterRemoteSiteId) via ping. If they are not pingable, check for flakiness in WAN connectivity. " ::= { vmwNsxTFederationFeature 17 } vmwNsxTFederationGMToGMLatencyWarningClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFromGMPath, vmwNsxTDataCenterToGMPath } STATUS current DESCRIPTION "Latency is below expected levels between Global Managers vmwNsxTDataCenterFromGMPath and vmwNsxTDataCenterToGMPath. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTFederationFeature 18 } vmwNsxTFederationGMToGMSplitBrain NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterActiveGlobalManagers } STATUS current DESCRIPTION "Multiple Global Manager nodes are active: vmwNsxTDataCenterActiveGlobalManagers. Only one Global Manager node must be active at any time. Action required: Configure only one Global Manager node as active and all other Global Manager nodes as standby. " ::= { vmwNsxTFederationFeature 9 } vmwNsxTFederationGMToGMSplitBrainClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterActiveGlobalManager } STATUS current DESCRIPTION "Global Manager node vmwNsxTDataCenterActiveGlobalManager is the only active Global Manager node now. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTFederationFeature 10 } vmwNsxTFederationGMToGMSynchronizationError NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFromGMPath, vmwNsxTDataCenterToGMPath, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteId } STATUS current DESCRIPTION "Active Global Manager vmwNsxTDataCenterFromGMPath to Standby Global Manager vmwNsxTDataCenterToGMPath cannot synchronize for more than 5 minutes. Action required: Check the connectivity from Global Manager vmwNsxTDataCenterFromGMPath(vmwNsxTDataCenterSiteId) to the Global Manager vmwNsxTDataCenterToGMPath(vmwNsxTDataCenterRemoteSiteId) via ping. " ::= { vmwNsxTFederationFeature 19 } vmwNsxTFederationGMToGMSynchronizationErrorClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFromGMPath, vmwNsxTDataCenterToGMPath } STATUS current DESCRIPTION "Synchronization from active Global Manager vmwNsxTDataCenterFromGMPath to standby vmwNsxTDataCenterToGMPath is healthy. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTFederationFeature 20 } vmwNsxTFederationGMToGMSynchronizationWarning NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFromGMPath, vmwNsxTDataCenterToGMPath, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteId } STATUS current DESCRIPTION "Active Global Manager vmwNsxTDataCenterFromGMPath to Standby Global Manager vmwNsxTDataCenterToGMPath can not synchronize. Action required: Check the connectivity from Global Manager vmwNsxTDataCenterFromGMPath(vmwNsxTDataCenterSiteId) to the Global Manager vmwNsxTDataCenterToGMPath(vmwNsxTDataCenterRemoteSiteId) via ping. " ::= { vmwNsxTFederationFeature 21 } vmwNsxTFederationGMToGMSynchronizationWarningClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFromGMPath, vmwNsxTDataCenterToGMPath } STATUS current DESCRIPTION "Synchronization from active Global Manager vmwNsxTDataCenterFromGMPath to standby vmwNsxTDataCenterToGMPath is healthy. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTFederationFeature 22 } vmwNsxTFederationGMToLMLatencyWarning NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSiteName, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterRemoteSiteId, vmwNsxTDataCenterLatencyValue, vmwNsxTDataCenterLatencyThreshold } STATUS current DESCRIPTION "Latency between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) has reached vmwNsxTDataCenterLatencyValue which is above the threshold value of vmwNsxTDataCenterLatencyThreshold. Action required: 1. Check the network connectivity between remote site and local site via ping. 2. Ensure port TCP/1236 traffic is allowed between the local and remote sites. 3. Check /var/log/async-replicator/ar.log to see if there are errors reported. " ::= { vmwNsxTFederationFeature 27 } vmwNsxTFederationGMToLMLatencyWarningClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSiteName, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterRemoteSiteId, vmwNsxTDataCenterLatencyValue, vmwNsxTDataCenterLatencyThreshold } STATUS current DESCRIPTION "Latency between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) has reached vmwNsxTDataCenterLatencyValue which below the threshold value of vmwNsxTDataCenterLatencyThreshold. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTFederationFeature 28 } vmwNsxTFederationGMToLMSynchronizationError NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSiteName, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterRemoteSiteId, vmwNsxTDataCenterFlowIdentifier, vmwNsxTDataCenterSyncIssueReason } STATUS current DESCRIPTION "Data synchronization between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed for the vmwNsxTDataCenterFlowIdentifier for an extended period. Reason: vmwNsxTDataCenterSyncIssueReason. Action required: 1. Check the network connectivity between remote site and local site via ping. 2. Ensure port TCP/1236 traffic is allowed between the local and remote sites. 3. Ensure the async-replicator service is running on both local and remote sites. Invoke the GET /api/v1/node/services/async_replicator/status NSX API or the `get service async_replicator` NSX CLI command to determine if the service is running. If not running, invoke the POST /api/v1/node/services/async_replicator?action=restart NSX API or the `restart service async_replicator` NSX CLI to restart the service. 4. Check /var/log/async-replicator/ar.log to see if there are errors reported. 5. Collect a support bundle and contact the NSX support team. " ::= { vmwNsxTFederationFeature 23 } vmwNsxTFederationGMToLMSynchronizationErrorClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSiteName, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterRemoteSiteId, vmwNsxTDataCenterFlowIdentifier } STATUS current DESCRIPTION "Sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized for vmwNsxTDataCenterFlowIdentifier. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTFederationFeature 24 } vmwNsxTFederationGMToLMSynchronizationWarning NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSiteName, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterRemoteSiteId, vmwNsxTDataCenterFlowIdentifier, vmwNsxTDataCenterSyncIssueReason } STATUS current DESCRIPTION "Data synchronization between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed for the vmwNsxTDataCenterFlowIdentifier. Reason: vmwNsxTDataCenterSyncIssueReason Action required: 1. Check the network connectivity between remote site and local site via ping. 2. Ensure port TCP/1236 traffic is allowed between the local and remote sites. 3. Ensure the async-replicator service is running on both local and remote sites. Invoke the GET /api/v1/node/services/async_replicator/status NSX API or the `get service async_replicator` NSX CLI command to determine if the service is running. If not running, invoke the POST /api/v1/node/services/async_replicator?action=restart NSX API or the `restart service async_replicator` NSX CLI to restart the service. 4. Check /var/log/async-replicator/ar.log to see if there are errors reported. " ::= { vmwNsxTFederationFeature 25 } vmwNsxTFederationGMToLMSynchronizationWarningClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSiteName, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterRemoteSiteId, vmwNsxTDataCenterFlowIdentifier } STATUS current DESCRIPTION "Sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized for vmwNsxTDataCenterFlowIdentifier. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTFederationFeature 26 } vmwNsxTFederationLMRestoreWhileConfigImportInProgress NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSiteName, vmwNsxTDataCenterSiteId } STATUS current DESCRIPTION "Config import from site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is in progress. However site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is restored from backup by the administrator leaving it in an inconsistent state. Action required: 1. Log in to NSX Global Manager appliance CLI. 2. Switch to root. 3. Invoke the NSX API DELETE http://localhost:64440/gm/api/v1/infra/sites//onboarding/status in local mode, this will delete site on-boarding status for Global Manager. 4. Re-initiate config on-boarding again. " ::= { vmwNsxTFederationFeature 31 } vmwNsxTFederationLMRestoreWhileConfigImportInProgressClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSiteName, vmwNsxTDataCenterSiteId } STATUS current DESCRIPTION "Config inconsistency at site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is resolved. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTFederationFeature 32 } vmwNsxTFederationLmToLmSynchronizationError NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSiteName, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterRemoteSiteId } STATUS current DESCRIPTION "The synchronization between vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed for more than 15 minutes. Action required: 1. Invoke the NSX CLI command `get site-replicator remote-sites` to get connection state between the remote locations. If a remote location is connected but not synchronized, it is possible that the location is still in the process of master resolution. In this case, wait for around 10 seconds and try invoking the CLI again to check for the state of the remote location. If a location is disconnected, try the next step. 2. Check the connectivity from Local Manager (LM) in location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) to the LMs in location vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) via ping. If they are not pingable, check for flakiness in WAN connectivity. If there are no physical network connectivity issues, try the next step. 3. Check the /var/log/cloudnet/nsx-ccp.log file on the Manager nodes in the local cluster in location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) that triggered the alarm to see if there are any cross-site communication errors. In addition, also look for errors being logged by the nsx-appl-proxy subcomponent within /var/log/syslog. " ::= { vmwNsxTFederationFeature 3 } vmwNsxTFederationLmToLmSynchronizationErrorClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSiteName, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterRemoteSiteId } STATUS current DESCRIPTION "Remote sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTFederationFeature 4 } vmwNsxTFederationLmToLmSynchronizationWarning NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSiteName, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterRemoteSiteId } STATUS current DESCRIPTION "The synchronization between vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed for more than 3 minutes. Action required: 1. Invoke the NSX CLI command `get site-replicator remote-sites` to get connection state between the remote locations. If a remote location is connected but not synchronized, it is possible that the location is still in the process of master resolution. In this case, wait for around 10 seconds and try invoking the CLI again to check for the state of the remote location. If a location is disconnected, try the next step. 2. Check the connectivity from Local Manager (LM) in location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) to the LMs in location vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) via ping. If they are not pingable, check for flakiness in WAN connectivity. If there are no physical network connectivity issues, try the next step. 3. Check the /var/log/cloudnet/nsx-ccp.log file on the Manager nodes in the local cluster in location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) that triggered the alarm to see if there are any cross-site communication errors. In addition, also look for errors being logged by the nsx-appl-proxy subcomponent within /var/log/syslog. " ::= { vmwNsxTFederationFeature 5 } vmwNsxTFederationLmToLmSynchronizationWarningClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSiteName, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterRemoteSiteId } STATUS current DESCRIPTION "Remote locations vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTFederationFeature 6 } vmwNsxTFederationQueueOccupancyThresholdExceeded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterQueueName, vmwNsxTDataCenterSiteName, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterRemoteSiteId, vmwNsxTDataCenterQueueSize, vmwNsxTDataCenterQueueSizeThreshold } STATUS current DESCRIPTION "Queue (vmwNsxTDataCenterQueueName) used for syncing data between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) has reached size vmwNsxTDataCenterQueueSize which is at or above the maximum threshold of vmwNsxTDataCenterQueueSizeThreshold%. Action required: Queue size can exceed threshold due to communication issue with remote site or an overloaded system. Check system performance and /var/log/async-replicator/ar.log to see if there are any errors reported. " ::= { vmwNsxTFederationFeature 29 } vmwNsxTFederationQueueOccupancyThresholdExceededClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterQueueName, vmwNsxTDataCenterSiteName, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterRemoteSiteId, vmwNsxTDataCenterQueueSize, vmwNsxTDataCenterQueueSizeThreshold } STATUS current DESCRIPTION "Queue (vmwNsxTDataCenterQueueName) used for syncing data between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) has reached size vmwNsxTDataCenterQueueSize which is below the maximum threshold of vmwNsxTDataCenterQueueSizeThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTFederationFeature 30 } vmwNsxTFederationRtepBGPDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterBGPSourceIP, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterBGPNeighborIP, vmwNsxTDataCenterFailureReason } STATUS current DESCRIPTION "RTEP (Remote Tunnel Endpoint) BGP session from source IP vmwNsxTDataCenterBGPSourceIP to remote location vmwNsxTDataCenterRemoteSiteName neighbor IP vmwNsxTDataCenterBGPNeighborIP is down. Reason: vmwNsxTDataCenterFailureReason. Action required: 1. Invoke the NSX CLI command `get logical-routers` on the affected edge node. 2. Switch to REMOTE_TUNNEL_VRF context. 3. Invoke the NSX CLI command `get bgp neighbor summary` to check the BGP neighbor status. 4. Alternatively, invoke the NSX API GET /api/v1/transport-nodes//inter-site/bgp/summary to get the BGP neighbor status. 5. Invoke the NSX CLI command `get interfaces` and check if the correct RTEP IP address is assigned to the interface with name remote-tunnel-endpoint. 6. Check if the ping is working successfully between assigned RTEP IP address (vmwNsxTDataCenterBGPSourceIP) and the remote location vmwNsxTDataCenterRemoteSiteName neighbor IP vmwNsxTDataCenterBGPNeighborIP. 7. Check /var/log/syslog for any errors related to BGP. 8. Invoke the NSX API GET or PUT /api/v1/transport-nodes/ to get/update remote_tunnel_endpoint configuration on the edge node. This will update the RTEP IP assigned to the affected edge node. If the reason indicates `Edge is not ready`, check why the Edge node is not in good state. 1. Invoke the NSX CLI command `get edge-cluster status` to check reason why Edge node might be down. 2. Invoke the NSX CLI commands `get bfd-config` and `get bfd-sessions` to check if BFD is running well. 3. Check any Edge health related alarms to get more information. " ::= { vmwNsxTFederationFeature 1 } vmwNsxTFederationRtepBGPDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterBGPSourceIP, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterBGPNeighborIP } STATUS current DESCRIPTION "RTEP (Remote Tunnel Endpoint) BGP session from source IP vmwNsxTDataCenterBGPSourceIP to remote location vmwNsxTDataCenterRemoteSiteName neighbor IP vmwNsxTDataCenterBGPNeighborIP is established. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTFederationFeature 2 } vmwNsxTFederationRtepConnectivityLost NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterRemoteSiteName } STATUS current DESCRIPTION "Edge node vmwNsxTDataCenterTransportNodeName lost RTEP (Remote Tunnel Endpoint) connectivity with remote location vmwNsxTDataCenterRemoteSiteName. Action required: 1. Invoke the NSX CLI command `get logical-routers` on the affected edge node vmwNsxTDataCenterTransportNodeName. 2. Switch to REMOTE_TUNNEL_VRF context. 3. Invoke the NSX CLI command `get bgp neighbor summary` to check the BGP neighbor status. 4. Alternatively, invoke the NSX API GET /api/v1/transport-nodes//inter-site/bgp/summary to get the BGP neighbor status. 5. Invoke the NSX CLI command `get interfaces` and check if the correct RTEP IP address is assigned to the interface with name remote-tunnel-endpoint. 6. Check if the ping is working successfully between assigned RTEP IP address and the RTEP IP addresses on the remote location vmwNsxTDataCenterRemoteSiteName. 7. Check /var/log/syslog for any errors related to BGP. 8. Invoke the NSX API GET or PUT /api/v1/transport-nodes/ to get/update remote_tunnel_endpoint configuration on the edge node. This will update the RTEP IP assigned to the affected edge node vmwNsxTDataCenterTransportNodeName. " ::= { vmwNsxTFederationFeature 7 } vmwNsxTFederationRtepConnectivityLostClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterRemoteSiteName } STATUS current DESCRIPTION "Edge node vmwNsxTDataCenterTransportNodeName has restored RTEP (Remote Tunnel Endpoint) connectivity with remote location vmwNsxTDataCenterRemoteSiteName. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTFederationFeature 8 } -- ********************************************************** -- GatewayFirewall feature event notifications -- ********************************************************** vmwNsxTGatewayFirewallFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the GatewayFirewall feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 39 } vmwNsxTGatewayFirewallFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for GatewayFirewall feature notifications. " ::= { vmwNsxTGatewayFirewallFeaturePrefix 0 } vmwNsxTGatewayFirewallICMPFlowCountExceeded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFirewallICMPFlowUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Gateway firewall flow table usage for ICMP traffic on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallICMPFlowUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. New flows will be dropped by Gateway firewall when usage reaches the maximum limit. Action required: Log in as the admin user on Edge node and invoke the NSX CLI command `get firewall interface stats | json` by using right interface uuid and check flow table usage for ICMP flows. Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node. " ::= { vmwNsxTGatewayFirewallFeature 21 } vmwNsxTGatewayFirewallICMPFlowCountExceededClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTGatewayFirewallFeature 22 } vmwNsxTGatewayFirewallICMPFlowCountHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFirewallICMPFlowUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Gateway firewall flow table usage for ICMP on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallICMPFlowUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. New flows will be dropped by Gateway firewall when usage reaches the maximum limit. Action required: Log in as the admin user on Edge node and invoke the NSX CLI command `get firewall interface stats | json` by using right interface uuid and check flow table usege for ICMP flows. Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node. " ::= { vmwNsxTGatewayFirewallFeature 23 } vmwNsxTGatewayFirewallICMPFlowCountHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Gateway firewall flow table usage for ICMP on logical router vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTGatewayFirewallFeature 24 } vmwNsxTGatewayFirewallIPFlowCountExceeded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFirewallIPFlowUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Gateway firewall flow table usage for IP traffic on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallIPFlowUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. New flows will be dropped by Gateway firewall when usage reaches the maximum limit. Action required: Log in as the admin user on Edge node and invoke the NSX CLI command `get firewall interface stats | json` by using right interface uuid and check flow table usage for IP flows. Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node. " ::= { vmwNsxTGatewayFirewallFeature 25 } vmwNsxTGatewayFirewallIPFlowCountExceededClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTGatewayFirewallFeature 26 } vmwNsxTGatewayFirewallIPFlowCountHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFirewallIPFlowUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Gateway firewall flow table usage for IP on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallIPFlowUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. New flows will be dropped by Gateway firewall when usage reaches the maximum limit. Action required: Log in as the admin user on Edge node and invoke the NSX CLI command `get firewall interface stats | json` by using right interface uuid and check flow table usege for IP flows. Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node. " ::= { vmwNsxTGatewayFirewallFeature 27 } vmwNsxTGatewayFirewallIPFlowCountHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Gateway firewall flow table usage for non IP flows on logical router vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTGatewayFirewallFeature 28 } vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceeded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFirewallHalfopenFlowUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Gateway firewall flow table usage for TCP half-open traffic on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallHalfopenFlowUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. New flows will be dropped by Gateway firewall when usage reaches the maximum limit. Action required: Log in as the admin user on Edge node and invoke the NSX CLI command `get firewall interface stats | json` by using right interface uuid and check flow table usage for TCP half-open flows. Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node. " ::= { vmwNsxTGatewayFirewallFeature 29 } vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceededClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTGatewayFirewallFeature 30 } vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFirewallHalfopenFlowUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Gateway firewall flow table usage for TCP on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallHalfopenFlowUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. New flows will be dropped by Gateway firewall when usage reaches the maximum limit. Action required: Log in as the admin user on Edge node and invoke the NSX CLI command `get firewall interface stats | json` by using right interface uuid and check flow table usege for TCP half-open flow. Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node. " ::= { vmwNsxTGatewayFirewallFeature 31 } vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Gateway firewall flow table usage for TCP half-open on logical router vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTGatewayFirewallFeature 32 } vmwNsxTGatewayFirewallUDPFlowCountExceeded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFirewallUDPFlowUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Gateway firewall flow table usage for UDP traffic on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallUDPFlowUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. New flows will be dropped by Gateway firewall when usage reaches the maximum limit. Action required: Log in as the admin user on Edge node and invoke the NSX CLI command `get firewall interface stats | json` by using right interface uuid and check flow table usage for UDP flows. Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node. " ::= { vmwNsxTGatewayFirewallFeature 33 } vmwNsxTGatewayFirewallUDPFlowCountExceededClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached below the high threshold. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTGatewayFirewallFeature 34 } vmwNsxTGatewayFirewallUDPFlowCountHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterFirewallUDPFlowUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "Gateway firewall flow table usage for UDP on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallUDPFlowUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. New flows will be dropped by Gateway firewall when usage reaches the maximum limit. Action required: Log in as the admin user on Edge node and invoke the NSX CLI command `get firewall interface stats | json` by using right interface uuid and check flow table usege for UDP flows. Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node. " ::= { vmwNsxTGatewayFirewallFeature 35 } vmwNsxTGatewayFirewallUDPFlowCountHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Gateway firewall flow table usage for UDP on logical router vmwNsxTDataCenterEntityId has reached below the high threshold. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTGatewayFirewallFeature 36 } -- ********************************************************** -- Groups feature event notifications -- ********************************************************** vmwNsxTGroupsFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the Groups feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 54 } vmwNsxTGroupsFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for Groups feature notifications. " ::= { vmwNsxTGroupsFeaturePrefix 0 } vmwNsxTGroupsGroupSizeLimitExceeded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterGroupId, vmwNsxTDataCenterGroupSize, vmwNsxTDataCenterGroupMaxNumberLimit, vmwNsxTDataCenterIPCount, vmwNsxTDataCenterMacCount, vmwNsxTDataCenterVifCount, vmwNsxTDataCenterLspCount, vmwNsxTDataCenterLrpCount, vmwNsxTDataCenterSidCount } STATUS current DESCRIPTION "Group vmwNsxTDataCenterGroupId has at least vmwNsxTDataCenterGroupSize translated elements which is at or greater than the maximum numbers limit of vmwNsxTDataCenterGroupMaxNumberLimit. This can result in long processing times and can lead to timeouts and outages. The current count for each element type is as follows. IP sets:vmwNsxTDataCenterIPCount, MAC sets:vmwNsxTDataCenterMacCount, VIFS:vmwNsxTDataCenterVifCount, Logical switch ports:vmwNsxTDataCenterLspCount, Logical router ports:vmwNsxTDataCenterLrpCount, AdGroups:vmwNsxTDataCenterSidCount. Action required: 1. Consider adjusting group elements in oversized group vmwNsxTDataCenterGroupId. 2. Consider splitting oversized group vmwNsxTDataCenterGroupId to multiple smaller groups and distributing members of oversized group to these groups. " ::= { vmwNsxTGroupsFeature 3 } vmwNsxTGroupsGroupSizeLimitExceededClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterGroupId, vmwNsxTDataCenterGroupMaxNumberLimit } STATUS current DESCRIPTION "Total number of elements in group vmwNsxTDataCenterGroupId is below the maximum limit of vmwNsxTDataCenterGroupMaxNumberLimit. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTGroupsFeature 4 } -- ********************************************************** -- HighAvailability feature event notifications -- ********************************************************** vmwNsxTHighAvailabilityFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the HighAvailability feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 21 } vmwNsxTHighAvailabilityFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for HighAvailability feature notifications. " ::= { vmwNsxTHighAvailabilityFeaturePrefix 0 } vmwNsxTHighAvailabilityTier0GatewayFailover NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterPreviousGatewayState, vmwNsxTDataCenterCurrentGatewayState, vmwNsxTDataCenterServiceRouterId } STATUS current DESCRIPTION "The tier0 gateway vmwNsxTDataCenterEntityId failover from vmwNsxTDataCenterPreviousGatewayState to vmwNsxTDataCenterCurrentGatewayState, service-router vmwNsxTDataCenterServiceRouterId. Action required: Invoke the NSX CLI command `get logical-router ` to identify the tier0 service-router vrf ID. Switch to the vrf context by invoking `vrf ` then invoke `get high-availability status` to determine the service that is down. " ::= { vmwNsxTHighAvailabilityFeature 9 } vmwNsxTHighAvailabilityTier0GatewayFailoverClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The tier0 gateway vmwNsxTDataCenterEntityId is now up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTHighAvailabilityFeature 10 } vmwNsxTHighAvailabilityTier0ServiceGroupFailover NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterHaState, vmwNsxTDataCenterTransportNodeId, vmwNsxTDataCenterHaState2, vmwNsxTDataCenterTransportNodeId2 } STATUS current DESCRIPTION "Service-group cluster vmwNsxTDataCenterEntityId currently does not have an active instance. It is in state vmwNsxTDataCenterHaState (where 0 is down, 1 is standby and 2 is active) on Edge node vmwNsxTDataCenterTransportNodeId and in state vmwNsxTDataCenterHaState2 on Edge node vmwNsxTDataCenterTransportNodeId2. Action required: Invoke the NSX CLI command `get logical-router service_group` to check all service-groups configured under a given service-router. Examine the output for reason for a service-group leaving active state. " ::= { vmwNsxTHighAvailabilityFeature 13 } vmwNsxTHighAvailabilityTier0ServiceGroupFailoverClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "Tier0 service-group cluster vmwNsxTDataCenterEntityId now has one active instance on Edge node vmwNsxTDataCenterTransportNodeId. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTHighAvailabilityFeature 14 } vmwNsxTHighAvailabilityTier0ServiceGroupReducedRedundancy NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceRouterId, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "Service-group cluster vmwNsxTDataCenterEntityId attached to Tier0 service-router vmwNsxTDataCenterServiceRouterId on Edge node vmwNsxTDataCenterTransportNodeId has failed. As a result, the service-group cluster currently does not have a standby instance. Action required: Invoke the NSX CLI command `get logical-router service_group` to check all service-groups configured under a given service-router. Examine the output for failure reason for a previously standby service-group. " ::= { vmwNsxTHighAvailabilityFeature 17 } vmwNsxTHighAvailabilityTier0ServiceGroupReducedRedundancyClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterHaState, vmwNsxTDataCenterTransportNodeId, vmwNsxTDataCenterHaState2, vmwNsxTDataCenterTransportNodeId2 } STATUS current DESCRIPTION "Service-group cluster vmwNsxTDataCenterEntityId is in state vmwNsxTDataCenterHaState (where 0 is down, 1 is standby and 2 is active) on Edge node vmwNsxTDataCenterTransportNodeId and state vmwNsxTDataCenterHaState2 on Edge node vmwNsxTDataCenterTransportNodeId2. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTHighAvailabilityFeature 18 } vmwNsxTHighAvailabilityTier1GatewayFailover NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterPreviousGatewayState, vmwNsxTDataCenterCurrentGatewayState, vmwNsxTDataCenterServiceRouterId } STATUS current DESCRIPTION "The tier1 gateway vmwNsxTDataCenterEntityId failover from vmwNsxTDataCenterPreviousGatewayState to vmwNsxTDataCenterCurrentGatewayState, service-router vmwNsxTDataCenterServiceRouterId. Action required: Invoke the NSX CLI command `get logical-router ` to identify the tier1 service-router vrf ID. Switch to the vrf context by invoking `vrf ` then invoke `get high-availability status` to determine the service that is down. " ::= { vmwNsxTHighAvailabilityFeature 11 } vmwNsxTHighAvailabilityTier1GatewayFailoverClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The tier1 gateway vmwNsxTDataCenterEntityId is now up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTHighAvailabilityFeature 12 } vmwNsxTHighAvailabilityTier1ServiceGroupFailover NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterHaState, vmwNsxTDataCenterTransportNodeId, vmwNsxTDataCenterHaState2, vmwNsxTDataCenterTransportNodeId2 } STATUS current DESCRIPTION "Service-group cluster vmwNsxTDataCenterEntityId currently does not have an active instance. It is in state vmwNsxTDataCenterHaState (where 0 is down, 1 is standby and 2 is active) on Edge node vmwNsxTDataCenterTransportNodeId and in state vmwNsxTDataCenterHaState2 on Edge node vmwNsxTDataCenterTransportNodeId2. Action required: Invoke the NSX CLI command `get logical-router service_group` to check all service-groups configured under a given service-router. Examine the output for reason for a service-group leaving active state. " ::= { vmwNsxTHighAvailabilityFeature 15 } vmwNsxTHighAvailabilityTier1ServiceGroupFailoverClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "Tier1 service-group cluster vmwNsxTDataCenterEntityId now has one active instance on Edge node vmwNsxTDataCenterTransportNodeId. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTHighAvailabilityFeature 16 } vmwNsxTHighAvailabilityTier1ServiceGroupReducedRedundancy NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceRouterId, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "Service-group cluster vmwNsxTDataCenterEntityId attached to Tier1 service-router vmwNsxTDataCenterServiceRouterId on Edge node vmwNsxTDataCenterTransportNodeId has failed. As a result, the service-group cluster currently does not have a standby instance. Action required: Invoke the NSX CLI command `get logical-router service_group` to check all service-groups configured under a given service-router. Examine the output for failure reason for a previously standby service-group. " ::= { vmwNsxTHighAvailabilityFeature 19 } vmwNsxTHighAvailabilityTier1ServiceGroupReducedRedundancyClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterHaState, vmwNsxTDataCenterTransportNodeId, vmwNsxTDataCenterHaState2, vmwNsxTDataCenterTransportNodeId2 } STATUS current DESCRIPTION "Service-group cluster vmwNsxTDataCenterEntityId is in state vmwNsxTDataCenterHaState (where 0 is down, 1 is standby and 2 is active) on Edge node vmwNsxTDataCenterTransportNodeId and state vmwNsxTDataCenterHaState2 on Edge node vmwNsxTDataCenterTransportNodeId2. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTHighAvailabilityFeature 20 } -- ********************************************************** -- IdentityFirewall feature event notifications -- ********************************************************** vmwNsxTIdentityFirewallFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the IdentityFirewall feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 36 } vmwNsxTIdentityFirewallFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for IdentityFirewall feature notifications. " ::= { vmwNsxTIdentityFirewallFeaturePrefix 0 } vmwNsxTIdentityFirewallConnectivityToLDAPServerLost NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterLDAPServer } STATUS current DESCRIPTION "The connectivity to LDAP server vmwNsxTDataCenterLDAPServer is lost. Action required: Check 1. The LDAP server is reachable from NSX nodes. 2. The LDAP server details are configured correctly in NSX. 3. The LDAP server is running correctly. 4. There are no firewalls blocking access between the LDAP server and NSX nodes. Afer the issue is fixed, use TEST CONNECTION in NSX UI under Identity Firewall AD to test the connection. " ::= { vmwNsxTIdentityFirewallFeature 1 } vmwNsxTIdentityFirewallConnectivityToLDAPServerLostClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterLDAPServer } STATUS current DESCRIPTION "The connectivity to LDAP server vmwNsxTDataCenterLDAPServer is restored. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIdentityFirewallFeature 2 } vmwNsxTIdentityFirewallErrorInDeltaSync NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDirectoryDomain } STATUS current DESCRIPTION "Errors occurred while performing delta sync with vmwNsxTDataCenterDirectoryDomain. Action required: 1. Check if there are any connectivity to LDAP server lost alarms. 2. Find the error details in /var/log/syslog. Around the alarm trigger time, search for text: Error happened when synchronize LDAP objects. 3. Check with AD administrator if there are any recent AD changes which may cause the errors. 4. If the errors persist, collect the technical support bundle and contact VMware technical support. " ::= { vmwNsxTIdentityFirewallFeature 3 } vmwNsxTIdentityFirewallErrorInDeltaSyncClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDirectoryDomain } STATUS current DESCRIPTION "No errors occurred while performing delta sync with vmwNsxTDataCenterDirectoryDomain. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIdentityFirewallFeature 4 } -- ********************************************************** -- InfrastructureCommunication feature event notifications -- ********************************************************** vmwNsxTInfrastructureCommunicationFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the InfrastructureCommunication feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 7 } vmwNsxTInfrastructureCommunicationFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for InfrastructureCommunication feature notifications. " ::= { vmwNsxTInfrastructureCommunicationFeaturePrefix 0 } vmwNsxTInfrastructureCommunicationEdgeTunnelsDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The overall tunnel status of Edge node vmwNsxTDataCenterEntityId is down. Action required: Invoke the NSX CLI command `get tunnel-ports` to get all tunnel ports, then check each tunnel's stats by invoking NSX CLI command `get tunnel-port stats` to check if there are any drops. Also check /var/log/syslog if there are tunnel related errors. " ::= { vmwNsxTInfrastructureCommunicationFeature 17 } vmwNsxTInfrastructureCommunicationEdgeTunnelsDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The tunnels of Edge node vmwNsxTDataCenterEntityId have been restored. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTInfrastructureCommunicationFeature 18 } -- ********************************************************** -- InfrastructureService feature event notifications -- ********************************************************** vmwNsxTInfrastructureServiceFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the InfrastructureService feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 19 } vmwNsxTInfrastructureServiceFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for InfrastructureService feature notifications. " ::= { vmwNsxTInfrastructureServiceFeaturePrefix 0 } vmwNsxTInfrastructureServiceApplicationCrashed NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNodeDisplayOrHostName, vmwNsxTDataCenterCoreDumpCount } STATUS current DESCRIPTION "Application on NSX node vmwNsxTDataCenterNodeDisplayOrHostName has crashed. The number of core files found is vmwNsxTDataCenterCoreDumpCount. Collect the Support Bundle including core dump files and contact VMware Support team. Action required: Collect Support Bundle for NSX node vmwNsxTDataCenterNodeDisplayOrHostName using NSX Manager UI or API. Note, core dumps can be set to move or copy into NSX Tech Support Bundle in order to remove or preserve the local copy on node. Copy of Support Bundle with core dump files is essential for VMware Support team to troubleshoot the issue and it is best recommended to save a latest copy of Tech Support Bundle including core dump files before removing core dump files from system. Refer KB article for more details. " ::= { vmwNsxTInfrastructureServiceFeature 9 } vmwNsxTInfrastructureServiceApplicationCrashedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "All core dump files are withdrawn from system. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTInfrastructureServiceFeature 10 } vmwNsxTInfrastructureServiceEdgeServiceStatusChanged NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeServiceName, vmwNsxTDataCenterPreviousServiceState, vmwNsxTDataCenterCurrentServiceState, vmwNsxTDataCenterServiceDownReason } STATUS current DESCRIPTION "The service vmwNsxTDataCenterEdgeServiceName changed from vmwNsxTDataCenterPreviousServiceState to vmwNsxTDataCenterCurrentServiceState. vmwNsxTDataCenterServiceDownReason Action required: On the Edge node, verify the service hasn't exited due to an error by looking for core files in the /var/log/core directory. In addition, invoke the NSX CLI command `get services` to confirm whether the service is stopped. If so, invoke `start service ` to restart the service. " ::= { vmwNsxTInfrastructureServiceFeature 1 } vmwNsxTInfrastructureServiceEdgeServiceStatusChangedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeServiceName, vmwNsxTDataCenterPreviousServiceState, vmwNsxTDataCenterCurrentServiceState } STATUS current DESCRIPTION "The service vmwNsxTDataCenterEdgeServiceName changed from vmwNsxTDataCenterPreviousServiceState to vmwNsxTDataCenterCurrentServiceState. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTInfrastructureServiceFeature 2 } vmwNsxTInfrastructureServiceEdgeServiceStatusDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeServiceName, vmwNsxTDataCenterServiceDownReason } STATUS current DESCRIPTION "The service vmwNsxTDataCenterEdgeServiceName is down for at least one minute. vmwNsxTDataCenterServiceDownReason Action required: On the Edge node, verify the service hasn't exited due to an error by looking for core files in the /var/log/core directory. In addition, invoke the NSX CLI command `get services` to confirm whether the service is stopped. If so, invoke `start service ` to restart the service. " ::= { vmwNsxTInfrastructureServiceFeature 3 } vmwNsxTInfrastructureServiceEdgeServiceStatusDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEdgeServiceName } STATUS current DESCRIPTION "The service vmwNsxTDataCenterEdgeServiceName is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTInfrastructureServiceFeature 4 } vmwNsxTInfrastructureServiceMetricsDeliveryFailure NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterMetricsTargetAlias, vmwNsxTDataCenterMetricsTargetAddress, vmwNsxTDataCenterMetricsTargetPort } STATUS current DESCRIPTION "Failed to deliver metrics from SHA to target vmwNsxTDataCenterMetricsTargetAlias(vmwNsxTDataCenterMetricsTargetAddress:vmwNsxTDataCenterMetricsTargetPort). Action required: User should perform the following checks in order to exclude the problem causing the failure: 1. Check if target address vmwNsxTDataCenterMetricsTargetAddress and port vmwNsxTDataCenterMetricsTargetPort (default is 443 in the case port is not specified) passed down to connect is the expected target, 2. Check if the certificate is correct by `/opt/vmware/nsx-nestdb/bin/nestdb-cli --cmd 'put vmware.nsx.nestdb.CommonAgentHostConfigMsg'`, 3. Check if target vmwNsxTDataCenterMetricsTargetAddress is reachable, 4. Check if the metric manager on target vmwNsxTDataCenterMetricsTargetAddress is running by `docker ps | grep metrics_manager`, 5. Check if port vmwNsxTDataCenterMetricsTargetPort is opened by `netstat -a | grep vmwNsxTDataCenterMetricsTargetPort` on target, 6. Check if ALLOW firewall rule is installed on the node by `iptables -S OUTPUT | grep vmwNsxTDataCenterMetricsTargetPort`(EDGE/UA) or `localcli network firewall ruleset list | grep nsx-sha-tsdb`(ESX), 7. Restart SHA daemon to see if it could be solved by `/etc/init.d/netopa restart`(ESX) or `/etc/init.d/nsx-netopa restart`(EDGE) or `/etc/init.d/nsx-sha restart`(UA). " ::= { vmwNsxTInfrastructureServiceFeature 19 } vmwNsxTInfrastructureServiceMetricsDeliveryFailureClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterMetricsTargetAlias, vmwNsxTDataCenterMetricsTargetAddress, vmwNsxTDataCenterMetricsTargetPort } STATUS current DESCRIPTION "Metrics delivery to target vmwNsxTDataCenterMetricsTargetAlias(vmwNsxTDataCenterMetricsTargetAddress:vmwNsxTDataCenterMetricsTargetPort) recovered. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTInfrastructureServiceFeature 20 } vmwNsxTInfrastructureServiceServiceStatusUnknown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceName } STATUS current DESCRIPTION "The service vmwNsxTDataCenterServiceName has been unresponsive for 10 seconds. Action required: Verify vmwNsxTDataCenterServiceName service is still running by invoking `/etc/init.d/vmwNsxTDataCenterServiceName status`. If the service is reported as running, it may need to get restarted which can be done by `/etc/init.d/vmwNsxTDataCenterServiceName restart`. Rerun the status command to verify the service is now running. If the script `/etc/init.d/vmwNsxTDataCenterServiceName` is unavailable, invoke `systemctl vmwNsxTDataCenterServiceName status` and restart by `systemctl vmwNsxTDataCenterServiceName restart` with root priviledges. If restarting the service does not resolve the issue or if the issue reoccurs after a successful restart, contact VMware Support. " ::= { vmwNsxTInfrastructureServiceFeature 7 } vmwNsxTInfrastructureServiceServiceStatusUnknownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceName } STATUS current DESCRIPTION "The service vmwNsxTDataCenterServiceName is responsive again. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTInfrastructureServiceFeature 8 } vmwNsxTInfrastructureServiceServiceStatusUnknownOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceName, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "The service vmwNsxTDataCenterServiceName on DPU vmwNsxTDataCenterDPUId has been unresponsive for 10 seconds. Action required: Verify vmwNsxTDataCenterServiceName service on DPU vmwNsxTDataCenterDPUId is still running by invoking `/etc/init.d/vmwNsxTDataCenterServiceName status`. If the service is reported as running, it may need to get restarted which can be done by `/etc/init.d/vmwNsxTDataCenterServiceName restart`. Rerun the status command to verify the service is now running. If restarting the service does not resolve the issue or if the issue reoccurs after a successful restart, contact VMware Support. " ::= { vmwNsxTInfrastructureServiceFeature 11 } vmwNsxTInfrastructureServiceServiceStatusUnknownOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceName, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "The service vmwNsxTDataCenterServiceName on DPU vmwNsxTDataCenterDPUId is responsive again. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTInfrastructureServiceFeature 12 } -- ********************************************************** -- IntelligenceCommunication feature event notifications -- ********************************************************** vmwNsxTIntelligenceCommunicationFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the IntelligenceCommunication feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 9 } vmwNsxTIntelligenceCommunicationFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for IntelligenceCommunication feature notifications. " ::= { vmwNsxTIntelligenceCommunicationFeaturePrefix 0 } vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnected NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The flow exporter on Transport node vmwNsxTDataCenterEntityId is disconnected from the Intelligence node's messaging broker. Data collection is affected. Action required: Restart the messaging service if it is not running in the Intelligence node. Resolve the network connection failure between the Transport node flow exporter and the Intelligence node. " ::= { vmwNsxTIntelligenceCommunicationFeature 7 } vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnectedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The flow exporter on Transport node vmwNsxTDataCenterEntityId has reconnected to the Intelligence node's messaging broker. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIntelligenceCommunicationFeature 8 } -- ********************************************************** -- IntelligenceHealth feature event notifications -- ********************************************************** vmwNsxTIntelligenceHealthFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the IntelligenceHealth feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 6 } vmwNsxTIntelligenceHealthFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for IntelligenceHealth feature notifications. " ::= { vmwNsxTIntelligenceHealthFeaturePrefix 0 } vmwNsxTIntelligenceHealthCPUUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Use the top command to check which processes have the most CPU usages, and then check /var/log/syslog and these processes' local logs to see if there are any outstanding errors to be resolved. " ::= { vmwNsxTIntelligenceHealthFeature 41 } vmwNsxTIntelligenceHealthCPUUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIntelligenceHealthFeature 42 } vmwNsxTIntelligenceHealthCPUUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Use the top command to check which processes have the most CPU usages, and then check /var/log/syslog and these processes' local logs to see if there are any outstanding errors to be resolved. " ::= { vmwNsxTIntelligenceHealthFeature 43 } vmwNsxTIntelligenceHealthCPUUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIntelligenceHealthFeature 44 } vmwNsxTIntelligenceHealthDataDiskPartitionUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of disk partition /data on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Stop NSX intelligence data collection until the disk usage is below the threshold. Examine disk partition /data and see if there are any unexpected large files that can be removed. " ::= { vmwNsxTIntelligenceHealthFeature 45 } vmwNsxTIntelligenceHealthDataDiskPartitionUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of disk partition /data on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIntelligenceHealthFeature 46 } vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of disk partition /data on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Stop NSX intelligence data collection until the disk usage is below the threshold. In the NSX UI, navigate to System | Appliances | NSX Intelligence Appliance. Then click ACTONS, Stop Collecting Data. " ::= { vmwNsxTIntelligenceHealthFeature 47 } vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of disk partition /data on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIntelligenceHealthFeature 48 } vmwNsxTIntelligenceHealthDiskUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Examine disk partition vmwNsxTDataCenterDiskPartitionName and see if there are any unexpected large files that can be removed. " ::= { vmwNsxTIntelligenceHealthFeature 49 } vmwNsxTIntelligenceHealthDiskUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIntelligenceHealthFeature 50 } vmwNsxTIntelligenceHealthDiskUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Examine disk partition vmwNsxTDataCenterDiskPartitionName and see if there are any unexpected large files that can be removed. " ::= { vmwNsxTIntelligenceHealthFeature 51 } vmwNsxTIntelligenceHealthDiskUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIntelligenceHealthFeature 52 } vmwNsxTIntelligenceHealthMemoryUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Use the top command to check which processes have the most memory usages, and then check /var/log/syslog and these processes' local logs to see if there are any outstanding errors to be resolved. " ::= { vmwNsxTIntelligenceHealthFeature 53 } vmwNsxTIntelligenceHealthMemoryUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIntelligenceHealthFeature 54 } vmwNsxTIntelligenceHealthMemoryUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Use the top command to check which processes have the most memory usages, and then check /var/log/syslog and these processes' local logs to see if there are any outstanding errors to be resolved. " ::= { vmwNsxTIntelligenceHealthFeature 55 } vmwNsxTIntelligenceHealthMemoryUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIntelligenceHealthFeature 56 } vmwNsxTIntelligenceHealthNodeStatusDegraded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceName, vmwNsxTDataCenterIntelligenceNodeId } STATUS current DESCRIPTION "Intelligence node vmwNsxTDataCenterIntelligenceNodeId is degraded. Action required: Invoke the NSX API GET /napp/api/v1/platform/monitor/category/health to check which specific pod is down and the reason behind it. Invoke the following CLI command to restart the degraded service: `kubectl rollout restart -n ` " ::= { vmwNsxTIntelligenceHealthFeature 57 } vmwNsxTIntelligenceHealthNodeStatusDegradedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceName, vmwNsxTDataCenterIntelligenceNodeId } STATUS current DESCRIPTION "Intelligence node vmwNsxTDataCenterIntelligenceNodeId is running properly. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIntelligenceHealthFeature 58 } vmwNsxTIntelligenceHealthStorageLatencyHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The storage latency of disk partition vmwNsxTDataCenterDiskPartitionName on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold milliseconds. Action required: Transient high storage latency may happen due to spike of I/O requests. If storage latency remains high for more than 30 minutes, consider deploying NSX Intelligence appliance in a low latency disk, or not sharing the same storage device with other VMs. " ::= { vmwNsxTIntelligenceHealthFeature 63 } vmwNsxTIntelligenceHealthStorageLatencyHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The storage latency of disk partition vmwNsxTDataCenterDiskPartitionName on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold milliseconds. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIntelligenceHealthFeature 64 } -- ********************************************************** -- IPAM feature event notifications -- ********************************************************** vmwNsxTIPAMFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the IPAM feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 38 } vmwNsxTIPAMFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for IPAM feature notifications. " ::= { vmwNsxTIPAMFeaturePrefix 0 } vmwNsxTIPAMIPBlockUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntentPath } STATUS current DESCRIPTION "IP block usage of vmwNsxTDataCenterIntentPath is very high. IP block nearing its total capacity, creation of subnet using IP block might fail. Action required: Review IP block usage. Use new IP block for resource creation or delete unused IP subnet from the IP block. To check subnet being used for IP Block. From NSX UI, navigate to Networking | IP Address pools | IP Address pools tab. Select IP pools where IP block being used, check Subnets and Allocated IPs column on UI. If no allocation has been used for the IP pool and it is not going to be used in future then delete subnet or IP pool. Use following API to check if IP block being used by IP pool and also check if any IP allocation done: To get configured subnets of an IP pool, invoke the NSX API GET /policy/api/v1/infra/ip-pools//ip-subnets To get IP allocations, invoke the NSX API GET /policy/api/v1/infra/ip-pools//ip-allocations Note: Deletion of IP pool/subnet should only be done if it does not have any allocated IPs and it is not going to be used in future. " ::= { vmwNsxTIPAMFeature 1 } vmwNsxTIPAMIPBlockUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntentPath } STATUS current DESCRIPTION "IP block usage of vmwNsxTDataCenterIntentPath is below threshold level. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIPAMFeature 2 } vmwNsxTIPAMIPPoolUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntentPath } STATUS current DESCRIPTION "IP pool usage of vmwNsxTDataCenterIntentPath is very high. Creation of entity/service depends on IP being allocated from IP pool might fail. Action required: Review IP pool usage. Release unused ip allocations from IP pool or create new IP pool and use it. From NSX UI navigate to Networking | IP Address pools | IP Address pools tab. Select IP pools and check Allocated IPs column, this will show IPs allocated from the IP pool. If user see any IPs are not being used then those IPs can be released. To release unused IP allocations, invoke the NSX API DELETE /policy/api/v1/infra/ip-pools//ip-allocations/ " ::= { vmwNsxTIPAMFeature 3 } vmwNsxTIPAMIPPoolUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIntentPath } STATUS current DESCRIPTION "IP pool usage of vmwNsxTDataCenterIntentPath is normal now. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTIPAMFeature 4 } -- ********************************************************** -- Licenses feature event notifications -- ********************************************************** vmwNsxTLicensesFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the Licenses feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 5 } vmwNsxTLicensesFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for Licenses feature notifications. " ::= { vmwNsxTLicensesFeaturePrefix 0 } vmwNsxTLicensesLicenseExpired NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterLicenseEditionType, vmwNsxTDataCenterDisplayedLicenseKey } STATUS current DESCRIPTION "The vmwNsxTDataCenterLicenseEditionType license key ending with vmwNsxTDataCenterDisplayedLicenseKey, has expired. Action required: Add a new, non-expired license using the NSX UI by navigating to System | Licenses then click ADD and specify the key of the new license. The expired license should be deleted by checking the checkbox of the license, then click DELETE. " ::= { vmwNsxTLicensesFeature 1 } vmwNsxTLicensesLicenseExpiredClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterLicenseEditionType, vmwNsxTDataCenterDisplayedLicenseKey } STATUS current DESCRIPTION "The expired vmwNsxTDataCenterLicenseEditionType license key ending with vmwNsxTDataCenterDisplayedLicenseKey, has been removed, updated or is no longer about to expire. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTLicensesFeature 2 } vmwNsxTLicensesLicenseIsAboutToExpire NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterLicenseEditionType, vmwNsxTDataCenterDisplayedLicenseKey } STATUS current DESCRIPTION "The vmwNsxTDataCenterLicenseEditionType license key ending with vmwNsxTDataCenterDisplayedLicenseKey, is about to expire. Action required: The license is about to expire in several days. Plan to add a new, non-expiring license using the NSX UI by navigating to System | Licenses then click ADD and specify the key of the new license. The expired license should be deleted by checking the checkbox of the license, then click DELETE. " ::= { vmwNsxTLicensesFeature 3 } vmwNsxTLicensesLicenseIsAboutToExpireClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterLicenseEditionType, vmwNsxTDataCenterDisplayedLicenseKey } STATUS current DESCRIPTION "The expiring vmwNsxTDataCenterLicenseEditionType license key ending with vmwNsxTDataCenterDisplayedLicenseKey, has been removed, updated or is no longer about to expire. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTLicensesFeature 4 } -- ********************************************************** -- LoadBalancer feature event notifications -- ********************************************************** vmwNsxTLoadBalancerFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the LoadBalancer feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 17 } vmwNsxTLoadBalancerFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for LoadBalancer feature notifications. " ::= { vmwNsxTLoadBalancerFeaturePrefix 0 } vmwNsxTLoadBalancerDLBStatusDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The distributed load balancer service vmwNsxTDataCenterEntityId is down. Action required: On ESXi host node, invoke the NSX CLI command `get load-balancer status`. If 'Conflict LSP' is reported, check whether this LSP is attached to other load balancer service. Check whether this conflict is acceptable. If 'Not Ready LSP' is reported, check the status of this LSP by invoking NSX CLI command `get logical-switch-port status`. " ::= { vmwNsxTLoadBalancerFeature 17 } vmwNsxTLoadBalancerDLBStatusDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The distributed load balancer service vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTLoadBalancerFeature 18 } vmwNsxTLoadBalancerLBCPUVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of load balancer vmwNsxTDataCenterEntityId is very high. The threshold is vmwNsxTDataCenterSystemUsageThreshold%. Action required: If the load balancer CPU utilization is higher than system usage threshold, the workload is too high for this load balancer. Rescale the load balancer service by changing the load balancer size from small to medium or from medium to large. If the CPU utilization of this load balancer is still high, consider adjusting the Edge appliance form factor size or moving load balancer services to other Edge nodes for the applicable workload. " ::= { vmwNsxTLoadBalancerFeature 1 } vmwNsxTLoadBalancerLBCPUVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of load balancer vmwNsxTDataCenterEntityId is low enough. The threshold is vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTLoadBalancerFeature 2 } vmwNsxTLoadBalancerLBEdgeCapacityInUseHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The usage of load balancer service in Edge node vmwNsxTDataCenterEntityId is high. The threshold is vmwNsxTDataCenterSystemUsageThreshold%. Action required: If multiple LB instances have been configurerd in this Edge node, deploy a new Edge node and move some LB instances to that new Edge node. If only a single LB instance (small/medium/etc) has been configured in an Edge node of same size (small/medium/etc), deploy a new Edge of bigger size and move the LB instance to that new Edge node. " ::= { vmwNsxTLoadBalancerFeature 3 } vmwNsxTLoadBalancerLBEdgeCapacityInUseHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The usage of load balancer service in Edge node vmwNsxTDataCenterEntityId is low enough. The threshold is vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTLoadBalancerFeature 4 } vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The usage of pool members in Edge node vmwNsxTDataCenterEntityId is very high. The threshold is vmwNsxTDataCenterSystemUsageThreshold%. Action required: Deploy a new Edge node and move the load balancer service from existing Edge nodes to the newly deployed Edge node. " ::= { vmwNsxTLoadBalancerFeature 5 } vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The usage of pool members in Edge node vmwNsxTDataCenterEntityId is low enough. The threshold is vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTLoadBalancerFeature 6 } vmwNsxTLoadBalancerLBStatusDegraded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The load balancer service vmwNsxTDataCenterEntityId is degraded. Action required: For centralized load balancer: Check the load balancer status on standby Edge node as the degraded status means the load balancer status on standby Edge node is not ready. On standby Edge node, invoke the NSX CLI command `get load-balancer status`. If the LB-State of load balancer service is not_ready or there is no output, make the Edge node enter maintenance mode, then exit maintenance mode. For distributed load balancer: 1. Get detailed status by invoking NSX API GET /policy/api/v1/infra/lb-services//detailed-status?source=realtime 2. From API output, find ESXi host reporting a non-zero instance_number with status NOT_READY or CONFLICT. 3. On ESXi host node, invoke the NSX CLI command `get load-balancer status`. If 'Conflict LSP'is reported, check whether this LSP is attached to other load balancer service. Check whether this conflict is acceptable. If 'Not Ready LSP' is reported, check the status of this LSP by invoking NSX CLI command `get logical-switch-port status`. NOTE: You should ignore the alarm if it can be resolved automatically in 5 mins because the degraded status can be a transient status. " ::= { vmwNsxTLoadBalancerFeature 15 } vmwNsxTLoadBalancerLBStatusDegradedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The load balancer service vmwNsxTDataCenterEntityId is not degraded. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTLoadBalancerFeature 16 } vmwNsxTLoadBalancerLBStatusDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The centralized load balancer service vmwNsxTDataCenterEntityId is down. Action required: On active Edge node, check load balancer status by invoking the NSX CLI command `get load-balancer status`. If the LB-State of load balancer service is not_ready or there is no output, make the Edge node enter maintenance mode, then exit maintenance mode. " ::= { vmwNsxTLoadBalancerFeature 7 } vmwNsxTLoadBalancerLBStatusDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The centralized load balancer service vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTLoadBalancerFeature 8 } vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemory NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "The load balancer configuration vmwNsxTDataCenterEntityId is not realized, due to high memory usage on Edge node vmwNsxTDataCenterTransportNodeId. Action required: Prefer defining small and medium sized load balancers over large sized load balancers. Spread out load balancer services among the available Edge nodes. Reduce number of Virtual Servers defined. " ::= { vmwNsxTLoadBalancerFeature 19 } vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemoryClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "The load balancer configuration vmwNsxTDataCenterEntityId is realized on vmwNsxTDataCenterTransportNodeId. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTLoadBalancerFeature 20 } vmwNsxTLoadBalancerPoolStatusDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The load balancer pool vmwNsxTDataCenterEntityId status is down. Action required: Consult the load balancer pool to determine which members are down by invoking the NSX CLI command `get load-balancer pool status` or NSX API GET /policy/api/v1/infra/lb-services//lb-pools//detailed-status If DOWN or UNKNOWN is reported, verify the pool member. Check network connectivity from the load balancer to the impacted pool members. Validate application health of each pool member. Also validate the health of each pool member using the configured monitor. When the health of the member is established, the pool member status is updated to healthy based on the 'Rise Count' configuration in the monitor. Remediate the issue by rebooting the pool member or make the Edge node enter maintenance mode, then exit maintenance mode. " ::= { vmwNsxTLoadBalancerFeature 9 } vmwNsxTLoadBalancerPoolStatusDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The load balancer pool vmwNsxTDataCenterEntityId status is up Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTLoadBalancerFeature 10 } vmwNsxTLoadBalancerVirtualServerStatusDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The load balancer virtual server vmwNsxTDataCenterEntityId is down. Action required: Consult the load balancer pool to determine its status and verify its configuration. If incorrectly configured, reconfigure it and remove the load balancer pool from the virtual server then re-add it to the virtual server again. " ::= { vmwNsxTLoadBalancerFeature 11 } vmwNsxTLoadBalancerVirtualServerStatusDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The load balancer virtual server vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTLoadBalancerFeature 12 } -- ********************************************************** -- MalwarePreventionHealth feature event notifications -- ********************************************************** vmwNsxTMalwarePreventionHealthFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the MalwarePreventionHealth feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 48 } vmwNsxTMalwarePreventionHealthFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for MalwarePreventionHealth feature notifications. " ::= { vmwNsxTMalwarePreventionHealthFeaturePrefix 0 } vmwNsxTMalwarePreventionHealthAnalystAPIServiceUnreachable NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterMpsServiceName } STATUS current DESCRIPTION "Service vmwNsxTDataCenterMpsServiceName is degraded on NSX Application Platform. It is unable to communicate with analyst_api service. Inspected file verdicts may not be up to date. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services to check which service is degraded. Invoke the NSX API GET /napp/api/v1/platform/monitor/feature/health to check which specific service is down and the reason behind it. Invoke the following CLI command to restart the degraded service: `kubectl rollout restart -n ` Determine the status of Malware Prevention Cloud Connector service. For more information see: https://www.vmware.com/esx/support/askvmware/index.php?eventtype=malware_prevention_health.analyst_api_service_unreachable " ::= { vmwNsxTMalwarePreventionHealthFeature 1 } vmwNsxTMalwarePreventionHealthAnalystAPIServiceUnreachableClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterMpsServiceName } STATUS current DESCRIPTION "Service vmwNsxTDataCenterMpsServiceName is running properly on NSX Application Platform. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTMalwarePreventionHealthFeature 2 } vmwNsxTMalwarePreventionHealthDatabaseUnreachable NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterMpsServiceName } STATUS current DESCRIPTION "Service vmwNsxTDataCenterMpsServiceName is degraded on NSX Application Platform. It is unable to communicate with Malware Prevention database. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services to check which service is degraded. Invoke the NSX API GET /napp/api/v1/platform/monitor/feature/health to check which specific service is down and the reason behind it. Invoke the following CLI command to restart the degraded service: `kubectl rollout restart -n ` Determine the status of Malware Prevention Database service. For more information see: https://www.vmware.com/esx/support/askvmware/index.php?eventtype=malware_prevention_health.database_unreachable " ::= { vmwNsxTMalwarePreventionHealthFeature 3 } vmwNsxTMalwarePreventionHealthDatabaseUnreachableClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterMpsServiceName } STATUS current DESCRIPTION "Service vmwNsxTDataCenterMpsServiceName is running properly on NSX Application Platform. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTMalwarePreventionHealthFeature 4 } vmwNsxTMalwarePreventionHealthFileExtractSvcUnreachable NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterMpsServiceName, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterNSXEdgeTNName, vmwNsxTDataCenterNSXESXTNName } STATUS current DESCRIPTION "Service vmwNsxTDataCenterMpsServiceName is degraded on vmwNsxTDataCenterTransportNodeName. Unable to communicate with file extraction functionality. All file extraction abilities on the vmwNsxTDataCenterTransportNodeName are paused. Action required: 1. On the Edge node identified by vmwNsxTDataCenterNSXEdgeTNName, invoke the NSX CLI `get ids engine status` to check the status of file_extraction (IDS) service. Inspect /var/log/syslog to find any suspecting error(s) with the file extraction (IDS) service and/or vmwNsxTDataCenterMpsServiceName. 2. On the Host node identified by vmwNsxTDataCenterNSXESXTNName, log into the associated Malware Prevention Service VM vmwNsxTDataCenterEntityId and check the status of file extraction (NXGI) service. Inspect /var/log/syslog on the associated Malware Prevention Service VM vmwNsxTDataCenterEntityId to find any suspecting error(s). For more information see: https://www.vmware.com/esx/support/askvmware/index.php?eventtype=malware_prevention_health.file_extraction_service_unreachable " ::= { vmwNsxTMalwarePreventionHealthFeature 5 } vmwNsxTMalwarePreventionHealthFileExtractSvcUnreachableClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterMpsServiceName, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "Service vmwNsxTDataCenterMpsServiceName is running properly on vmwNsxTDataCenterTransportNodeName. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTMalwarePreventionHealthFeature 6 } vmwNsxTMalwarePreventionHealthNTICSRepSvcUnreachable NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterMpsServiceName } STATUS current DESCRIPTION "Service vmwNsxTDataCenterMpsServiceName is degraded on NSX Application Platform. It is unable to communicate with NTICS reputation service. Inspected file reputations may not be up to date. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services to check which service is degraded. Invoke the NSX API GET /napp/api/v1/platform/monitor/feature/health to check which specific service is down and the reason behind it. Invoke the following CLI command to restart the degraded service: `kubectl rollout restart -n ` Determine if access to NTICS service is down. " ::= { vmwNsxTMalwarePreventionHealthFeature 7 } vmwNsxTMalwarePreventionHealthNTICSRepSvcUnreachableClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterMpsServiceName } STATUS current DESCRIPTION "Service vmwNsxTDataCenterMpsServiceName is running properly on NSX Application Platform. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTMalwarePreventionHealthFeature 8 } vmwNsxTMalwarePreventionHealthServiceStatusDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterMpsServiceName, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterNSXEdgeTNName, vmwNsxTDataCenterNSXESXTNName } STATUS current DESCRIPTION "Service vmwNsxTDataCenterMpsServiceName is not running on vmwNsxTDataCenterTransportNodeName. Action required: 1. On the Edge node identified by vmwNsxTDataCenterNSXEdgeTNName, invoke the NSX CLI `get services` to check the status of vmwNsxTDataCenterMpsServiceName. Inspect /var/log/syslog to find any suspecting error(s). 2. On the Host node identified by vmwNsxTDataCenterNSXESXTNName, log into the associated Malware Prevention Service VM vmwNsxTDataCenterEntityId and check the status of vmwNsxTDataCenterMpsServiceName. Inspect /var/log/syslog on the associated Malware Prevention Service VM vmwNsxTDataCenterEntityId to find any suspecting error(s). For more information see: https://www.vmware.com/esx/support/askvmware/index.php?eventtype=malware_prevention_health.service_status_down " ::= { vmwNsxTMalwarePreventionHealthFeature 9 } vmwNsxTMalwarePreventionHealthServiceStatusDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterMpsServiceName, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "Service vmwNsxTDataCenterMpsServiceName is running properly on vmwNsxTDataCenterTransportNodeName. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTMalwarePreventionHealthFeature 10 } -- ********************************************************** -- ManagerHealth feature event notifications -- ********************************************************** vmwNsxTManagerHealthFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the ManagerHealth feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 1 } vmwNsxTManagerHealthFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for ManagerHealth feature notifications. " ::= { vmwNsxTManagerHealthFeaturePrefix 0 } vmwNsxTManagerHealthDuplicateIPAddress NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDuplicateIPAddress } STATUS current DESCRIPTION "Manager node vmwNsxTDataCenterEntityId IP address vmwNsxTDataCenterDuplicateIPAddress is currently being used by another device in the network. Action required: 1. Determine which device is using the Manager's IP address and assign the device a new IP address. Note, reconfiguring the Manager to use a new IP address is not supported. 2. Ensure the static IP address pool/DHCP server is configured correctly. 3. Correct the IP address of the device if it is manually assigned. " ::= { vmwNsxTManagerHealthFeature 17 } vmwNsxTManagerHealthDuplicateIPAddressClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDuplicateIPAddress } STATUS current DESCRIPTION "The device using the IP address assigned to Manager node vmwNsxTDataCenterEntityId appears to no longer be using vmwNsxTDataCenterDuplicateIPAddress. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTManagerHealthFeature 18 } vmwNsxTManagerHealthManagerConfigDiskUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Manager node disk partition /config has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of rising disk usage by the NSX Datastore service under the /config/corfu directory. Action required: Run the following tool and contact GSS if any issues are reported /opt/vmware/tools/support/inspect_checkpoint_issues.py " ::= { vmwNsxTManagerHealthFeature 13 } vmwNsxTManagerHealthManagerConfigDiskUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Manager node disk partition /config has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTManagerHealthFeature 14 } vmwNsxTManagerHealthManagerConfigDiskUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Manager node disk partition /config has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of high disk usage by the NSX Datastore service under the /config/corfu directory. Action required: Run the following tool and contact GSS if any issues are reported /opt/vmware/tools/support/inspect_checkpoint_issues.py " ::= { vmwNsxTManagerHealthFeature 15 } vmwNsxTManagerHealthManagerConfigDiskUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Manager node disk partition /config has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTManagerHealthFeature 16 } vmwNsxTManagerHealthManagerCPUUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review the configuration, running services and sizing of this Manager node. Consider adjusting the Manager appliance form factor size. " ::= { vmwNsxTManagerHealthFeature 1 } vmwNsxTManagerHealthManagerCPUUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTManagerHealthFeature 2 } vmwNsxTManagerHealthManagerCPUUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review the configuration, running services and sizing of this Manager node. Consider adjusting the Manager appliance form factor size. " ::= { vmwNsxTManagerHealthFeature 3 } vmwNsxTManagerHealthManagerCPUUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTManagerHealthFeature 4 } vmwNsxTManagerHealthManagerDiskUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Examine the partition with high usage and see if there are any unexpected large files that can be removed. " ::= { vmwNsxTManagerHealthFeature 9 } vmwNsxTManagerHealthManagerDiskUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTManagerHealthFeature 10 } vmwNsxTManagerHealthManagerDiskUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Examine the partition with high usage and see if there are any unexpected large files that can be removed. " ::= { vmwNsxTManagerHealthFeature 11 } vmwNsxTManagerHealthManagerDiskUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTManagerHealthFeature 12 } vmwNsxTManagerHealthManagerMemoryUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review the configuration, running services and sizing of this Manager node. Consider adjusting the Manager appliance form factor size. " ::= { vmwNsxTManagerHealthFeature 5 } vmwNsxTManagerHealthManagerMemoryUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTManagerHealthFeature 6 } vmwNsxTManagerHealthManagerMemoryUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review the configuration, running services and sizing of this Manager node. Consider adjusting the Manager appliance form factor size. " ::= { vmwNsxTManagerHealthFeature 7 } vmwNsxTManagerHealthManagerMemoryUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTManagerHealthFeature 8 } vmwNsxTManagerHealthMissingDNSEntryForManagerFQDN NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterManagerNodeName } STATUS current DESCRIPTION "The DNS configuration for Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterEntityId) is incorrect. The Manager node is dual-stack and/or CA-signed API certificate is used, but the IP address(es) of the Manager node do not resolve to an FQDN or resolve to different FQDNs. Action required: 1. Ensure proper DNS servers are configured in the Manager node. 2. Ensure proper A records and PTR records are configured in the DNS servers such that reverse lookup of the IP addresses of the Manager node return the same FQDN, and forward lookup of the FQDN return all IP addresses of the Manager node. 3. Alternatively, if the Manager node is not dual-stack, replace the CA-signed certificate for API service type with a self-signed certificate. " ::= { vmwNsxTManagerHealthFeature 28 } vmwNsxTManagerHealthMissingDNSEntryForManagerFQDNClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterManagerNodeName } STATUS current DESCRIPTION "The DNS configuration for Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterEntityId) is correct. Either the Manager node is not dual-stack and CA-signed API certificate is no longer used, or the IP address(es) of the Manager node resolve to the same FQDN. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTManagerHealthFeature 29 } vmwNsxTManagerHealthMissingDNSEntryForVipFQDN NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterIPv4Address, vmwNsxTDataCenterIPv6Address } STATUS current DESCRIPTION "In case of dual stack or CA-signed API certificate for a NSX Manager, virtual IPv4 address vmwNsxTDataCenterIPv4Address and virtual IPv6 address vmwNsxTDataCenterIPv6Address for Manager node vmwNsxTDataCenterEntityId should resolve to the same FQDN. Action required: Examine the DNS entry for the VIP addresses to see if they resolve to the same FQDN. " ::= { vmwNsxTManagerHealthFeature 33 } vmwNsxTManagerHealthMissingDNSEntryForVipFQDNClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Dual stack VIP addresses for Manager node vmwNsxTDataCenterEntityId resolved to same FQDN. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTManagerHealthFeature 34 } vmwNsxTManagerHealthOperationsDbDiskUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Manager node disk partition /nonconfig has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of rising disk usage by the NSX Datastore service under the /nonconfig/corfu directory. Action required: run the following tool and contact GSS if any issues are reported /opt/vmware/tools/support/inspect_checkpoint_issues.py --nonconfig " ::= { vmwNsxTManagerHealthFeature 19 } vmwNsxTManagerHealthOperationsDbDiskUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Manager node disk partition /nonconfig has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTManagerHealthFeature 20 } vmwNsxTManagerHealthOperationsDbDiskUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Manager node disk partition /nonconfig has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of high disk usage by the NSX Datastore service under the /nonconfig/corfu directory. Action required: Run the following tool and contact GSS if any issues are reported /opt/vmware/tools/support/inspect_checkpoint_issues.py --nonconfig " ::= { vmwNsxTManagerHealthFeature 21 } vmwNsxTManagerHealthOperationsDbDiskUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage for the Manager node disk partition /nonconfig has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTManagerHealthFeature 22 } vmwNsxTManagerHealthStorageError NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName } STATUS current DESCRIPTION "The following disk partition on the Manager node vmwNsxTDataCenterEntityId is in read-only mode: vmwNsxTDataCenterDiskPartitionName Action required: Examine the read-only partition to see if reboot resolves the issue or the disk needs to be replaced. Contact GSS for more information. " ::= { vmwNsxTManagerHealthFeature 23 } vmwNsxTManagerHealthStorageErrorClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDiskPartitionName } STATUS current DESCRIPTION "The following disk partition on the Manager node vmwNsxTDataCenterEntityId has recovered from read-only mode: vmwNsxTDataCenterDiskPartitionName Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTManagerHealthFeature 24 } -- ********************************************************** -- MTUCheck feature event notifications -- ********************************************************** vmwNsxTMTUCheckFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the MTUCheck feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 42 } vmwNsxTMTUCheckFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for MTUCheck feature notifications. " ::= { vmwNsxTMTUCheckFeaturePrefix 0 } vmwNsxTMTUCheckGlobalRouterMTUTooBig NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The global router MTU configuration is bigger than MTU of switches in overlay Transport Zone which connects to Tier0 or Tier1. Global router MTU value should be less than all switches MTU value by at least a 100 as we require 100 quota for Geneve encapsulation. Action required: 1. Navigate to System | Fabric | Settings | MTU Configuration Check | Inconsistent on the NSX UI to check more mismatch details. 2. Set the bigger MTU value on switches by invoking the NSX API PUT /api/v1/host-switch-profiles/ with mtu in the request body, or API PUT /api/v1/global-configs/SwitchingGlobalConfig with physical_uplink_mtu in request body. 3. Or set the smaller MTU value of global router configuration by invoking the NSX API PUT /api/v1/global-configs/RoutingGlobalConfig with logical_uplink_mtu in the request body. " ::= { vmwNsxTMTUCheckFeature 3 } vmwNsxTMTUCheckGlobalRouterMTUTooBigClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The global router MTU is less than the MTU of overlay Transport Zone now. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTMTUCheckFeature 4 } vmwNsxTMTUCheckMTUMismatchWithinTransportZone NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "MTU configuration mismatch between Transport Nodes (ESXi, KVM and Edge) attached to the same Transport Zone. MTU values on all switches attached to the same Transport Zone not being consistent will cause connectivity issues. Action required: 1. Navigate to System | Fabric | Settings | MTU Configuration Check | Inconsistent on the NSX UI to check more mismatch details. 2. Set the same MTU value on all switches attached to the same Transport Zone by invoking the NSX API PUT /api/v1/host-switch-profiles/ with mtu in the request body, or API PUT /api/v1/global-configs/SwitchingGlobalConfig with physical_uplink_mtu in request body. " ::= { vmwNsxTMTUCheckFeature 1 } vmwNsxTMTUCheckMTUMismatchWithinTransportZoneClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "All MTU values between Transport Nodes attached to the same Transport Zone are consistent now. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTMTUCheckFeature 2 } -- ********************************************************** -- NAT feature event notifications -- ********************************************************** vmwNsxTNATFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the NAT feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 46 } vmwNsxTNATFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for NAT feature notifications. " ::= { vmwNsxTNATFeaturePrefix 0 } vmwNsxTNATSNATPortUsageOnGatewayIsHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSNATIPAddress, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "SNAT ports usage on logical router vmwNsxTDataCenterEntityId for SNAT IP vmwNsxTDataCenterSNATIPAddress has reached the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. New flows will not be SNATed when usage reaches the maximum limit. Action required: Log in as the admin user on Edge node and invoke the NSX CLI command `get firewall connection state` by using the right interface uuid and check various SNAT mappings for the SNAT IP vmwNsxTDataCenterSNATIPAddress. Check traffic flows going through the gateway is not a denial-of-service attack or anomalous burst. If the traffic appears to be within the normal load but the alarm threshold is hit, consider adding more SNAT IP addresses to distribute the load or route new traffic to another Edge node. " ::= { vmwNsxTNATFeature 1 } vmwNsxTNATSNATPortUsageOnGatewayIsHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSNATIPAddress, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "SNAT ports usage on logical router vmwNsxTDataCenterEntityId for SNAT IP vmwNsxTDataCenterSNATIPAddress has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNATFeature 2 } -- ********************************************************** -- NCPHealth feature event notifications -- ********************************************************** vmwNsxTNCPHealthFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the NCPHealth feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 11 } vmwNsxTNCPHealthFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for NCPHealth feature notifications. " ::= { vmwNsxTNCPHealthFeaturePrefix 0 } vmwNsxTNCPHealthNCPPluginDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Manager Node has detected the NCP is down or unhealthy. Action required: To find the clusters which are having issues, use the NSX UI and navigate to the Alarms page. The Entity name value for this alarm instance identifies the cluster name. Or invoke the NSX API GET /api/v1/systemhealth/container-cluster/ncp/status to fetch all cluster statuses and determine the name of any clusters that report DOWN or UNKNOWN. Then on the NSX UI Inventory | Container | Clusters page find the cluster by name and click the Nodes tab which lists all Kubernetes and PAS cluster members. For Kubernetes cluster: 1. Check NCP Pod liveness by finding the K8s master node from all the cluster members and log onto the master node. Then invoke the kubectl command `kubectl get pods --all-namespaces`. If there is an issue with the NCP Pod, use kubectl logs command to check the issue and fix the error. 2. Check the connection between NCP and Kubernetes API server. The NSX CLI can be used inside the NCP Pod to check this connection status by invoking the following commands from the master VM. `kubectl exec -it -n nsx-system bash` `nsxcli` `get ncp-k8s-api-server status` If there is an issue with the connection, check both the network and NCP configurations. 3. Check the connection between NCP and NSX Manager. The NSX CLI can be used inside the NCP Pod to check this connection status by invoking the following command from the master VM. `kubectl exec -it -n nsx-system bash` `nsxcli` `get ncp-nsx status` If there is an issue with the connection, check both the network and NCP configurations. For PAS cluster: 1. Check the network connections between virtual machines and fix any network issues. 2. Check the status of both nodes and services and fix crashed nodes or services. Invoke the command `bosh vms` and `bosh instances -p` to check the status of nodes and services. " ::= { vmwNsxTNCPHealthFeature 3 } vmwNsxTNCPHealthNCPPluginDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Manager Node has detected the NCP is up or healthy again. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNCPHealthFeature 4 } -- ********************************************************** -- NodeAgentsHealth feature event notifications -- ********************************************************** vmwNsxTNodeAgentsHealthFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the NodeAgentsHealth feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 12 } vmwNsxTNodeAgentsHealthFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for NodeAgentsHealth feature notifications. " ::= { vmwNsxTNodeAgentsHealthFeaturePrefix 0 } vmwNsxTNodeAgentsHealthNodeAgentsDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The agents running inside the Node VM appear to be down. Action required: For ESX: 1. If Vmk50 is missing, refer to this Knowledge Base article https://kb.vmware.com/s/article/67432. 2. If Hyperbus 4094 is missing, restarting nsx-cfgagent or restarting the container host VM may help. 3. If container host VIF is blocked, check the connection to the Controller to make sure all configurations are sent down. 4. If nsx-cfg-agent has stopped, restart nsx-cfgagent. For KVM: 1. If Hyperbus namespace is missing, restarting the nsx-opsagent may help recreate the namespace. 2. If Hyperbus interface is missing inside the hyperbus namespace, restarting the nsx-opsagent may help. 3. If nsx-agent has stopped, restart nsx-agent. For Both ESX and KVM: 1. If the node-agent package is missing, check whether node-agent package has been successfully installed in the container host vm. 2. If the interface for node-agent in container host vm is down, check the eth1 interface status inside the container host vm. " ::= { vmwNsxTNodeAgentsHealthFeature 3 } vmwNsxTNodeAgentsHealthNodeAgentsDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The agents inside the Node VM are running. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNodeAgentsHealthFeature 4 } vmwNsxTNodeAgentsHealthNodeAgentsDownOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "The agents running inside the Node VM appear to be down on DPU vmwNsxTDataCenterDPUId. Action required: 1. If Vmk50 on DPU vmwNsxTDataCenterDPUId is missing, refer to this Knowledge Base article https://kb.vmware.com/s/article/67432. 2. If Hyperbus 4094 on DPU vmwNsxTDataCenterDPUId is missing, restarting nsx-cfgagent on DPU vmwNsxTDataCenterDPUId or restarting the container host VM may help. 3. If container host VIF is blocked, check the connection to the Controller to make sure all configurations are sent down. 4. If nsx-cfg-agent on DPU vmwNsxTDataCenterDPUId has stopped, restart nsx-cfgagent on DPU vmwNsxTDataCenterDPUId . 5. If the node-agent package is missing, check whether node-agent package has been successfully installed in the container host vm. 6. If the interface for node-agent in container host vm is down, check the eth1 interface status inside the container host vm. " ::= { vmwNsxTNodeAgentsHealthFeature 5 } vmwNsxTNodeAgentsHealthNodeAgentsDownOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "The agents inside the Node VM are running on DPU vmwNsxTDataCenterDPUId. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNodeAgentsHealthFeature 6 } -- ********************************************************** -- NSXApplicationPlatformCommunication feature event notifications -- ********************************************************** vmwNsxTNSXApplicationPlatformCommunicationFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the NSXApplicationPlatformCommunication feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 41 } vmwNsxTNSXApplicationPlatformCommunicationFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for NSXApplicationPlatformCommunication feature notifications. " ::= { vmwNsxTNSXApplicationPlatformCommunicationFeaturePrefix 0 } vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflow NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappMessagingLAGThreshold } STATUS current DESCRIPTION "The number of pending messages in the messaging topic Over Flow is above the pending message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold. Action required: Add nodes and then scale up the NSX Application Platform cluster. If bottleneck can be attributed to a specific service, for example, the analytics service, then scale up the specific service when the new nodes are added. " ::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 7 } vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflowClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappMessagingLAGThreshold } STATUS current DESCRIPTION "The number of pending messages in the messaging topic Over Flow is below the pending message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 8 } vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflow NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappMessagingLAGThreshold } STATUS current DESCRIPTION "The number of pending messages in the messaging topic Raw Flow is above the pending message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold. Action required: Add nodes and then scale up the NSX Application Platform cluster. If the bottleneck can be attributed to a specific service, for example, the analytics service, then scale up the specific service when the new nodes are added. " ::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 11 } vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflowClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappMessagingLAGThreshold } STATUS current DESCRIPTION "The number of pending messages in the messaging topic Raw Flow is below the pending message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 12 } vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnected NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId } STATUS current DESCRIPTION "The NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is disconnected from the NSX management cluster. Action required: Check whether the manager cluster certificate, manager node certificates, kafka certificate and ingress certificate match on both NSX Manager and the NSX Application Platform cluster. Check expiration dates of the above mentioned certificates to make sure they are valid. Check the network connection between NSX Manager and NSX Application Platform cluster and resolve any network connection failures. " ::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 1 } vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnectedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId } STATUS current DESCRIPTION "The NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is reconnected to the NSX management cluster. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 2 } vmwNsxTNSXApplicationPlatformCommunicationExpDisconnected NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The flow exporter on Transport node vmwNsxTDataCenterEntityId is disconnected from the NSX Application Platform cluster's messaging broker. Data collection is affected. Action required: Restart the messaging service if it is not running in the NSX Application Platform cluster. Resolve the network connection failure between the Transport node flow exporter and the NSX Application Platform cluster. " ::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 13 } vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The flow exporter on Transport node vmwNsxTDataCenterEntityId has reconnected to the NSX Application Platform cluster's messaging broker. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 14 } vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "The flow exporter on Transport node vmwNsxTDataCenterEntityId DPU vmwNsxTDataCenterDPUId is disconnected from the Intelligence node's messaging broker. Data collection is affected. Action required: Restart the messaging service if it is not running in the Intelligence node. Resolve the network connection failure between the Transport node flow exporter and the Intelligence node. " ::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 17 } vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "The flow exporter on Transport node vmwNsxTDataCenterEntityId DPU vmwNsxTDataCenterDPUId has reconnected to the Intelligence node's messaging broker. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 18 } -- ********************************************************** -- NSXApplicationPlatformHealth feature event notifications -- ********************************************************** vmwNsxTNSXApplicationPlatformHealthFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the NSXApplicationPlatformHealth feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 43 } vmwNsxTNSXApplicationPlatformHealthFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for NSXApplicationPlatformHealth feature notifications. " ::= { vmwNsxTNSXApplicationPlatformHealthFeaturePrefix 0 } vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Analytics service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or the Analytics service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 1 } vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Analytics service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 2 } vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Analytics service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or the Analytics service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 3 } vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Analytics service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 4 } vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Analytics service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not needed. Scale out all services or the Analytics service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 5 } vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Analytics service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 6 } vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Analytics service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not needed. Scale out all services or the Analytics service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 7 } vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Analytics service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 8 } vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Analytics service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or the Analytics service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 9 } vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Analytics service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 10 } vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Analytics service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or the Analytics service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 11 } vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Analytics service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 12 } vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services and check the System Load field of individual services to see which service is under pressure. See if the load can be reduced. If more computing power is required, click on the Scale Out button to request more resources. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 13 } vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 14 } vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services and check the System Load field of individual services to see which service is under pressure. See if the load can be reduced. If more computing power is required, click on the Scale Out button to request more resources. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 15 } vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 16 } vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services and check the Storage field of individual services to see which service is under pressure. See if the load can be reduced. If more disk storage is required, click on the Scale Out button to request more resources. If data storage service is under strain, another way is to click on the Scale Up button to increase disk size. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 17 } vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 18 } vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services and check the Storage field of individual services to see which service is under pressure. See if the load can be reduced. If more disk storage is required, click on the Scale Out button to request more resources. If data storage service is under strain, another way is to click on the Scale Up button to increase disk size. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 19 } vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 20 } vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services and check the Memory field of individual services to see which service is under pressure. See if the load can be reduced. If more memory is required, click on the Scale Out button to request more resources. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 21 } vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 22 } vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services and check the Memory field of individual services to see which service is under pressure. See if the load can be reduced. If more memory is required, click on the Scale Out button to request more resources. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 23 } vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 24 } vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Configuration Database service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 31 } vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Configuration Database service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 32 } vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Configuration Database service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 33 } vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Configuration Database service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 34 } vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Configuration Database service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not needed. Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 35 } vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Configuration Database service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 36 } vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Configuration Database service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not needed. Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 37 } vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Configuration Database service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 38 } vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Configuration Database service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 109 } vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Configuration Database service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 110 } vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Configuration Database service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 39 } vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Configuration Database service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 40 } vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Data Storage service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or the Data Storage service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 41 } vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Data Storage service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 42 } vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Data Storage service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or the Data Storage service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 43 } vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Data Storage service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 44 } vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Data Storage service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out or scale up the data storage service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 45 } vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Data Storage service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 46 } vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Data Storage service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out or scale up the data storage service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 47 } vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Data Storage service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 48 } vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Data Storage service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or the Data Storage service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 49 } vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Data Storage service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 50 } vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Data Storage service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or the Data Storage service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 51 } vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Data Storage service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 52 } vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Messaging service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or the Messaging service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 53 } vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Messaging service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 54 } vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Messaging service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or the Messaging service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 55 } vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Messaging service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 56 } vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Messaging service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not needed. Scale out all services or the Messaging service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 57 } vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Messaging service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 58 } vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Messaging service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not needed. Scale out all services or the Messaging service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 59 } vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Messaging service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 60 } vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Messaging service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or the Messaging service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 61 } vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Messaging service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 62 } vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Messaging service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or the Messaging service. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 63 } vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Messaging service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 64 } vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Metrics service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 97 } vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Metrics service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 98 } vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Metrics service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 99 } vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Metrics service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 100 } vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Metrics service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not needed. Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 101 } vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Metrics service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 102 } vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Metrics service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not needed. Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 103 } vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Metrics service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 104 } vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Metrics service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 105 } vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Metrics service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 106 } vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Metrics service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 107 } vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Metrics service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 108 } vmwNsxTNSXApplicationPlatformHealthNappStatusDegraded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId } STATUS current DESCRIPTION "NSX Application Platform cluster vmwNsxTDataCenterNappClusterId overall status is degraded. Action required: Get more information from alarms of nodes and services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 117 } vmwNsxTNSXApplicationPlatformHealthNappStatusDegradedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId } STATUS current DESCRIPTION "NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is running properly. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 118 } vmwNsxTNSXApplicationPlatformHealthNappStatusDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId } STATUS current DESCRIPTION "NSX Application Platform cluster vmwNsxTDataCenterNappClusterId overall status is down. Action required: Get more information from alarms of nodes and services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 119 } vmwNsxTNSXApplicationPlatformHealthNappStatusDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappClusterId } STATUS current DESCRIPTION "NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is running properly. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 120 } vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services and check the System Load field of individual services to see which service is under pressure. See if load can be reduced. If only a small minority of the nodes have high CPU usage, by default, Kubernetes will reschedule services automatically. If most nodes have high CPU usage and load cannot be reduced, click on the Scale Out button to request more resources. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 65 } vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 66 } vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services and check the System Load field of individual services to see which service is under pressure. See if load can be reduced. If only a small minority of the nodes have high CPU usage, by default, Kubernetes will reschedule services automatically. If most nodes have high CPU usage and load cannot be reduced, click on the Scale Out button to request more resources. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 67 } vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 68 } vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services and check the Storage field of individual services to see which service is under pressure. Clean up unused data or log to free up disk resources and see if the load can be reduced. If more disk storage is required, Scale Out the service under pressure. If data storage service is under strain, another way is to click on the Scale Up button to increase disk size. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 69 } vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 70 } vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services and check the Storage field of individual services to see which service is under pressure. Clean up unused data or log to free up disk resources and see if the load can be reduced. If more disk storage is required, Scale Out the service under pressure. If data storage service is under strain, another way is to click on the Scale Up button to increase disk size. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 71 } vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 72 } vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services and check the Memory field of individual services to see which service is under pressure. See if load can be reduced. If only a small minority of the nodes have high Memory usage, by default, Kubernetes will reschedule services automatically. If most nodes have high Memory usage and load cannot be reduced, click on the Scale Out button to request more resources. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 73 } vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 74 } vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services and check the Memory field of individual services to see which service is under pressure. See if load can be reduced. If only a small minority of the nodes have high Memory usage, by default, Kubernetes will reschedule services automatically. If most nodes have high Memory usage and load cannot be reduced, click on the Scale Out button to request more resources. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 75 } vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 76 } vmwNsxTNSXApplicationPlatformHealthNodeStatusDegraded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName } STATUS current DESCRIPTION "NSX Application Platform node vmwNsxTDataCenterNappNodeName is degraded. Action required: In the NSX UI, navigate to System | NSX Application Platform | Resources to check which node is degraded. Check network, memory and CPU usage of the node. Reboot the node if it is a worker node. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 77 } vmwNsxTNSXApplicationPlatformHealthNodeStatusDegradedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName } STATUS current DESCRIPTION "NSX Application Platform node vmwNsxTDataCenterNappNodeName is running properly. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 78 } vmwNsxTNSXApplicationPlatformHealthNodeStatusDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName } STATUS current DESCRIPTION "NSX Application Platform node vmwNsxTDataCenterNappNodeName is not running. Action required: In the NSX UI, navigate to System | NSX Application Platform | Resources to check which node is down. Check network, memory and CPU usage of the node. Reboot the node if it is a worker node. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 79 } vmwNsxTNSXApplicationPlatformHealthNodeStatusDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappNodeName } STATUS current DESCRIPTION "NSX Application Platform node vmwNsxTDataCenterNappNodeName is running properly. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 80 } vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Platform Services service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 81 } vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Platform Services service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 82 } vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Platform Services service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 83 } vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The CPU usage of Platform Services service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 84 } vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Platform Services service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not needed. Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 85 } vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Platform Services service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 86 } vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Platform Services service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not needed. Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 87 } vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The disk usage of Platform Services service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 88 } vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHigh NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Platform Services service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 89 } vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHighClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Platform Services service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 90 } vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHi NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Platform Services service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 91 } vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHiClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSystemUsageThreshold } STATUS current DESCRIPTION "The memory usage of Platform Services service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 92 } vmwNsxTNSXApplicationPlatformHealthServiceStatusDegraded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappServiceName } STATUS current DESCRIPTION "Service vmwNsxTDataCenterNappServiceName is degraded. The service may still be able to reach a quorum while pods associated with vmwNsxTDataCenterNappServiceName are not all stable. Resources consumed by these unstable pods may be released. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services to check which service is degraded. Invoke the NSX API GET /napp/api/v1/platform/monitor/feature/health to check which specific service is degraded and the reason behind it. Invoke the following CLI command to restart the degraded service if necessary: `kubectl rollout restart -n ` Degraded services can function correctly but performance is sub-optimal. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 93 } vmwNsxTNSXApplicationPlatformHealthServiceStatusDegradedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappServiceName } STATUS current DESCRIPTION "Service vmwNsxTDataCenterNappServiceName is running properly. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 94 } vmwNsxTNSXApplicationPlatformHealthServiceStatusDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappServiceName } STATUS current DESCRIPTION "Service vmwNsxTDataCenterNappServiceName is not running. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services to check which service is degraded. Invoke the NSX API GET /napp/api/v1/platform/monitor/feature/health to check which specific service is down and the reason behind it. Invoke the following CLI command to restart the degraded service: `kubectl rollout restart -n ` " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 95 } vmwNsxTNSXApplicationPlatformHealthServiceStatusDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterNappServiceName } STATUS current DESCRIPTION "Service vmwNsxTDataCenterNappServiceName is running properly. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTNSXApplicationPlatformHealthFeature 96 } -- ********************************************************** -- PasswordManagement feature event notifications -- ********************************************************** vmwNsxTPasswordManagementFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the PasswordManagement feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 4 } vmwNsxTPasswordManagementFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for PasswordManagement feature notifications. " ::= { vmwNsxTPasswordManagementFeaturePrefix 0 } vmwNsxTPasswordManagementPasswordExpirationApproaching NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterUsername, vmwNsxTDataCenterPasswordExpirationDays } STATUS current DESCRIPTION "The password for user vmwNsxTDataCenterUsername is approaching expiration in vmwNsxTDataCenterPasswordExpirationDays days. Action required: The password for the user vmwNsxTDataCenterUsername needs to be changed soon. For example, to apply a new password to a user, invoke the following NSX API with a valid password in the request body: PUT /api/v1/node/users/ where is the ID of the user. " ::= { vmwNsxTPasswordManagementFeature 1 } vmwNsxTPasswordManagementPasswordExpirationApproachingClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterUsername } STATUS current DESCRIPTION "The password for the user vmwNsxTDataCenterUsername has been changed successfully or is no longer expired or the user is no longer active. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTPasswordManagementFeature 2 } vmwNsxTPasswordManagementPasswordExpired NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterUsername } STATUS current DESCRIPTION "The password for user vmwNsxTDataCenterUsername has expired. Action required: The password for user vmwNsxTDataCenterUsername must be changed now to access the system. For example, to apply a new password to a user, invoke the following NSX API with a valid password in the request body: PUT /api/v1/node/users/ where is the ID of the user. If the admin user (with 10000) password has expired, admin must login to the system via SSH (if enabled) or console in order to change the password. Upon entering the current expired password, admin will be prompted to enter a new password. " ::= { vmwNsxTPasswordManagementFeature 3 } vmwNsxTPasswordManagementPasswordExpiredClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterUsername } STATUS current DESCRIPTION "The password for user vmwNsxTDataCenterUsername has been changed successfully or is no longer expired or the user is no longer active. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTPasswordManagementFeature 4 } vmwNsxTPasswordManagementPasswordIsAboutToExpire NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterUsername, vmwNsxTDataCenterPasswordExpirationDays } STATUS current DESCRIPTION "The password for user vmwNsxTDataCenterUsername is about to expire in vmwNsxTDataCenterPasswordExpirationDays days. Action required: Ensure the password for the user vmwNsxTDataCenterUsername is changed immediately. For example, to apply a new password to a user, invoke the following NSX API with a valid password in the request body: PUT /api/v1/node/users/ where is the ID of the user. " ::= { vmwNsxTPasswordManagementFeature 5 } vmwNsxTPasswordManagementPasswordIsAboutToExpireClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterUsername } STATUS current DESCRIPTION "The password for the user vmwNsxTDataCenterUsername has been changed successfully or is no longer expired or the user is no longer active. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTPasswordManagementFeature 6 } -- ********************************************************** -- PhysicalServer feature event notifications -- ********************************************************** vmwNsxTPhysicalServerFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the PhysicalServer feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 47 } vmwNsxTPhysicalServerFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for PhysicalServer feature notifications. " ::= { vmwNsxTPhysicalServerFeaturePrefix 0 } vmwNsxTPhysicalServerPhysicalServerInstallFailed NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "Physical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) installation failed. Action required: Navigate to System > Fabric > Nodes > Host Transport Nodes and resolve the error on the node. " ::= { vmwNsxTPhysicalServerFeature 1 } vmwNsxTPhysicalServerPhysicalServerInstallFailedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "Physical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) installation completed. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTPhysicalServerFeature 2 } vmwNsxTPhysicalServerPhysicalServerUninstallFailed NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "Physical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) uninstallation failed. Action required: Navigate to System > Fabric > Nodes > Host Transport Nodes and resolve the error on the node. " ::= { vmwNsxTPhysicalServerFeature 3 } vmwNsxTPhysicalServerPhysicalServerUninstallFailedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "Physical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) uninstallation completed. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTPhysicalServerFeature 4 } vmwNsxTPhysicalServerPhysicalServerUpgradeFailed NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "Physical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) upgrade failed. Action required: Navigate to System > Upgrade and resolve the error, then re-trigger the upgrade. " ::= { vmwNsxTPhysicalServerFeature 5 } vmwNsxTPhysicalServerPhysicalServerUpgradeFailedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeName } STATUS current DESCRIPTION "Physical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) upgrade completed. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTPhysicalServerFeature 6 } -- ********************************************************** -- PolicyConstraint feature event notifications -- ********************************************************** vmwNsxTPolicyConstraintFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the PolicyConstraint feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 53 } vmwNsxTPolicyConstraintFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for PolicyConstraint feature notifications. " ::= { vmwNsxTPolicyConstraintFeaturePrefix 0 } vmwNsxTPolicyConstraintCreationCountLimitReached NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterConstraintType, vmwNsxTDataCenterConstraintTypePath, vmwNsxTDataCenterCurrentCount, vmwNsxTDataCenterConstraintLimit } STATUS current DESCRIPTION "Entity count for type vmwNsxTDataCenterConstraintType in vmwNsxTDataCenterConstraintTypePath is currently at vmwNsxTDataCenterCurrentCount which reached the maximum limit of vmwNsxTDataCenterConstraintLimit. Action required: Review vmwNsxTDataCenterConstraintType usage. Update the constraint to increase the limit or delete unused vmwNsxTDataCenterConstraintType. " ::= { vmwNsxTPolicyConstraintFeature 1 } vmwNsxTPolicyConstraintCreationCountLimitReachedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterConstraintType } STATUS current DESCRIPTION "vmwNsxTDataCenterConstraintType Count is below threshold. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTPolicyConstraintFeature 2 } -- ********************************************************** -- Routing feature event notifications -- ********************************************************** vmwNsxTRoutingFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the Routing feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 28 } vmwNsxTRoutingFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for Routing feature notifications. " ::= { vmwNsxTRoutingFeaturePrefix 0 } vmwNsxTRoutingBFDDownOnExternalInterface NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterLrId, vmwNsxTDataCenterPeerAddress, vmwNsxTDataCenterSrId } STATUS current DESCRIPTION "In router vmwNsxTDataCenterLrId, BFD session for peer vmwNsxTDataCenterPeerAddress is down. Action required: 1. Invoke the NSX CLI command `get logical-routers`. 2. Switch to the service router vmwNsxTDataCenterSrId 3. Invoke the NSX CLI command `ping vmwNsxTDataCenterPeerAddress` to verify the connectivity. " ::= { vmwNsxTRoutingFeature 7 } vmwNsxTRoutingBFDDownOnExternalInterfaceClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterLrId, vmwNsxTDataCenterPeerAddress } STATUS current DESCRIPTION "In router vmwNsxTDataCenterLrId, BFD session for peer vmwNsxTDataCenterPeerAddress is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTRoutingFeature 8 } vmwNsxTRoutingBGPDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterLrId, vmwNsxTDataCenterBGPNeighborIP, vmwNsxTDataCenterFailureReason, vmwNsxTDataCenterSrId } STATUS current DESCRIPTION "In Router vmwNsxTDataCenterLrId, BGP neighbor vmwNsxTDataCenterEntityId (vmwNsxTDataCenterBGPNeighborIP) is down. Reason: vmwNsxTDataCenterFailureReason. Action required: 1. Invoke the NSX CLI command `get logical-routers`. 2. Switch to service-router vmwNsxTDataCenterSrId. If the reason indicates Network or config error - 3. Invoke the NSX CLI command `get bgp neighbor summary` to check the BGP neighbor status. If the reason indicates `Edge is not ready`, check why the Edge node is not in good state. 4. Invoke the NSX CLI command `get edge-cluster status` to check reason why Edge node might be down. 5. Invoke the NSX CLI commands `get bfd-config` and `get bfd-sessions` to check if BFD is running well. 6. Check any Edge health related alarms to get more information. Check /var/log/syslog to see if there are any errors related to BGP connectivity. " ::= { vmwNsxTRoutingFeature 1 } vmwNsxTRoutingBGPDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterLrId, vmwNsxTDataCenterBGPNeighborIP } STATUS current DESCRIPTION "In Router vmwNsxTDataCenterLrId, BGP neighbor vmwNsxTDataCenterEntityId (vmwNsxTDataCenterBGPNeighborIP) is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTRoutingFeature 2 } vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborApproaching NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSubsequentAddressFamily, vmwNsxTDataCenterBGPNeighborIP, vmwNsxTDataCenterPrefixesCountThreshold, vmwNsxTDataCenterPrefixesCountMax } STATUS current DESCRIPTION "Number of IPv4 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP reaches vmwNsxTDataCenterPrefixesCountThreshold. Limit defined for this peer is vmwNsxTDataCenterPrefixesCountMax. Action required: 1. Check the BGP routing policies in the external router. 2. Consider reducing the number of routes advertised by the BGP peer by applying routing policies and filters to the external router. 3. If required, increase the maximum prefixes settings under the BGP neighbor configuration section. " ::= { vmwNsxTRoutingFeature 39 } vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborApproachingClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSubsequentAddressFamily, vmwNsxTDataCenterBGPNeighborIP, vmwNsxTDataCenterPrefixesCountThreshold } STATUS current DESCRIPTION "Number of IPv4 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP is within the limit vmwNsxTDataCenterPrefixesCountThreshold. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTRoutingFeature 40 } vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborExceeded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSubsequentAddressFamily, vmwNsxTDataCenterBGPNeighborIP, vmwNsxTDataCenterPrefixesCountMax } STATUS current DESCRIPTION "Number of IPv4 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP exceeded the limit defined for this peer of vmwNsxTDataCenterPrefixesCountMax. Action required: 1. Check the BGP routing policies in the external router. 2. Consider reducing the number of routes advertised by the BGP peer by applying routing policies and filters to the external router. 3. If required, increase the maximum prefixes settings under the BGP neighbor configuration section. " ::= { vmwNsxTRoutingFeature 41 } vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborExceededClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSubsequentAddressFamily, vmwNsxTDataCenterBGPNeighborIP, vmwNsxTDataCenterPrefixesCountMax } STATUS current DESCRIPTION "Number of IPv4 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP is within the limit vmwNsxTDataCenterPrefixesCountMax. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTRoutingFeature 42 } vmwNsxTRoutingMaximumIPv4RouteLimitApproaching NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterRouteLimitThreshold, vmwNsxTDataCenterEdgeNode } STATUS current DESCRIPTION "IPv4 routes limit has reached vmwNsxTDataCenterRouteLimitThreshold on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action required: 1. Check route redistribution policies and routes received from all external peers. 2. Consider reducing the number of routes by applying routing policies and filters accordingly. " ::= { vmwNsxTRoutingFeature 43 } vmwNsxTRoutingMaximumIPv4RouteLimitApproachingClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterRouteLimitThreshold, vmwNsxTDataCenterEdgeNode } STATUS current DESCRIPTION "IPv4 routes are within the limit of vmwNsxTDataCenterRouteLimitThreshold on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTRoutingFeature 44 } vmwNsxTRoutingMaximumIPv4RouteLimitExceeded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterRouteLimitMaximum, vmwNsxTDataCenterEdgeNode } STATUS current DESCRIPTION "IPv4 routes has exceeded limit of vmwNsxTDataCenterRouteLimitMaximum on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action required: 1. Check route redistribution policies and routes received from all external peers. 2. Consider reducing the number of routes by applying routing policies and filters accordingly. " ::= { vmwNsxTRoutingFeature 45 } vmwNsxTRoutingMaximumIPv4RouteLimitExceededClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterRouteLimitMaximum, vmwNsxTDataCenterEdgeNode } STATUS current DESCRIPTION "IPv4 routes are within the limit of vmwNsxTDataCenterRouteLimitMaximum on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTRoutingFeature 46 } vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborApproaching NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSubsequentAddressFamily, vmwNsxTDataCenterBGPNeighborIP, vmwNsxTDataCenterPrefixesCountThreshold, vmwNsxTDataCenterPrefixesCountMax } STATUS current DESCRIPTION "Number of IPv6 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP reaches vmwNsxTDataCenterPrefixesCountThreshold. Limit defined for this peer is vmwNsxTDataCenterPrefixesCountMax. Action required: 1. Check the BGP routing policies in the external router. 2. Consider reducing the number of routes advertised by the BGP peer by applying routing policies and filters to the external router. 3. If required, increase the maximum prefixes settings under the BGP neighbor configuration section. " ::= { vmwNsxTRoutingFeature 47 } vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborApproachingClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSubsequentAddressFamily, vmwNsxTDataCenterBGPNeighborIP, vmwNsxTDataCenterPrefixesCountThreshold } STATUS current DESCRIPTION "Number of IPv6 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP is within the limit vmwNsxTDataCenterPrefixesCountThreshold. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTRoutingFeature 48 } vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborExceeded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSubsequentAddressFamily, vmwNsxTDataCenterBGPNeighborIP, vmwNsxTDataCenterPrefixesCountMax } STATUS current DESCRIPTION "Number of IPv6 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP exceeded the limit defined for this peer of vmwNsxTDataCenterPrefixesCountMax. Action required: 1. Check the BGP routing policies in the external router. 2. Consider reducing the number of routes advertised by the BGP peer by applying routing policies and filters to the external router. 3. If required, increase the maximum prefixes settings under the BGP neighbor configuration section. " ::= { vmwNsxTRoutingFeature 49 } vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborExceededClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSubsequentAddressFamily, vmwNsxTDataCenterBGPNeighborIP, vmwNsxTDataCenterPrefixesCountMax } STATUS current DESCRIPTION "Number of IPv6 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP is within the limit vmwNsxTDataCenterPrefixesCountMax. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTRoutingFeature 50 } vmwNsxTRoutingMaximumIPv6RouteLimitApproaching NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterRouteLimitThreshold, vmwNsxTDataCenterEdgeNode } STATUS current DESCRIPTION "IPv6 routes limit has reached vmwNsxTDataCenterRouteLimitThreshold on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action required: 1. Check route redistribution policies and routes received from all external peers. 2. Consider reducing the number of routes by applying routing policies and filters accordingly. " ::= { vmwNsxTRoutingFeature 51 } vmwNsxTRoutingMaximumIPv6RouteLimitApproachingClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterRouteLimitThreshold, vmwNsxTDataCenterEdgeNode } STATUS current DESCRIPTION "IPv6 routes are within the limit of vmwNsxTDataCenterRouteLimitThreshold on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTRoutingFeature 52 } vmwNsxTRoutingMaximumIPv6RouteLimitExceeded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterRouteLimitMaximum, vmwNsxTDataCenterEdgeNode } STATUS current DESCRIPTION "IPv6 routes has exceeded limit of vmwNsxTDataCenterRouteLimitMaximum on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action required: 1. Check route redistribution policies and routes received from all external peers. 2. Consider reducing the number of routes by applying routing policies and filters accordingly. " ::= { vmwNsxTRoutingFeature 53 } vmwNsxTRoutingMaximumIPv6RouteLimitExceededClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterRouteLimitMaximum, vmwNsxTDataCenterEdgeNode } STATUS current DESCRIPTION "IPv6 routes are within the limit of vmwNsxTDataCenterRouteLimitMaximum on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTRoutingFeature 54 } vmwNsxTRoutingOSPFNeighborWentDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterPeerAddress } STATUS current DESCRIPTION "OSPF neighbor vmwNsxTDataCenterPeerAddress moved from full to another state. Action required: 1. Invoke the NSX CLI command `get logical-routers` to get the vrf id and switch to TIER0 service router. 2. Run `get ospf neighbor` to check the current state of this neighbor. If the neighbor is not listed in the output, the neighbor has gone down or out of the network. 3. Invoke the NSX CLI command `ping ` to verify the connectivity. 4. Also, verify the configuration for both NSX and peer router to ensure that timers and area-id match. 5. Check /var/log/syslog to see if there are any errors related to connectivity. " ::= { vmwNsxTRoutingFeature 11 } vmwNsxTRoutingOSPFNeighborWentDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterPeerAddress } STATUS current DESCRIPTION "OSPF neighbor vmwNsxTDataCenterPeerAddress moved to full state. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTRoutingFeature 12 } vmwNsxTRoutingProxyARPNotConfiguredForServiceIP NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceIP, vmwNsxTDataCenterLrportId, vmwNsxTDataCenterLrId } STATUS current DESCRIPTION "Proxy ARP for Service IP vmwNsxTDataCenterServiceIP and Service entity vmwNsxTDataCenterEntityId is not configured as the number of ARP proxy entries generated due to overlap of the Service IP with subnet of lrport vmwNsxTDataCenterLrportId on Router vmwNsxTDataCenterLrId has exceeded the allowed threshold limit of 16384. Action required: Reconfigure the Service IP vmwNsxTDataCenterServiceIP for the Service entity vmwNsxTDataCenterEntityId or change the subnet of the lrport vmwNsxTDataCenterLrportId on Router vmwNsxTDataCenterLrId so that the proxy ARP entries generated due to the overlap between the Service IP and the subnet of lrport is less than the allowed threshold limit of 16384. " ::= { vmwNsxTRoutingFeature 13 } vmwNsxTRoutingProxyARPNotConfiguredForServiceIPClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterLrportId, vmwNsxTDataCenterLrId } STATUS current DESCRIPTION "Proxy ARP for Service entity vmwNsxTDataCenterEntityId is generated successfully as the overlap of service IP with subnet of lrport vmwNsxTDataCenterLrportId on Router vmwNsxTDataCenterLrId is within the allowed limit of 16384 entries. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTRoutingFeature 14 } vmwNsxTRoutingRoutingDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "All BGP/BFD sessions are down. Action required: Invoke the NSX CLI command `get logical-routers` to get the tier0 service router and switch to this vrf, then invoke the following NSX CLI commands. 1. `ping ` to verify connectivity. 2. `get bfd-config` and `get bfd-sessions` to check if BFD is running well. 3. `get bgp neighbor summary` to check if BGP is running well. Also check /var/log/syslog to see if there are any errors related to BGP connectivity. " ::= { vmwNsxTRoutingFeature 9 } vmwNsxTRoutingRoutingDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "At least one BGP/BFD session up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTRoutingFeature 10 } vmwNsxTRoutingStaticRoutingRemoved NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterLrId, vmwNsxTDataCenterStaticAddress, vmwNsxTDataCenterSrId } STATUS current DESCRIPTION "In router vmwNsxTDataCenterLrId, static route vmwNsxTDataCenterEntityId (vmwNsxTDataCenterStaticAddress) was removed because BFD was down. Action required: The static routing entry was removed because the BFD session was down. 1. Invoke the NSX CLI command `get logical-routers`. 2. Switch to the service-router vmwNsxTDataCenterSrId. 3. Invoke the NSX CLI command `ping ` to verify the connectivity. Also, verify the configuration in both NSX and the BFD peer to ensure that timers have not been changed. " ::= { vmwNsxTRoutingFeature 5 } vmwNsxTRoutingStaticRoutingRemovedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterLrId, vmwNsxTDataCenterStaticAddress } STATUS current DESCRIPTION "In router vmwNsxTDataCenterLrId, static route vmwNsxTDataCenterEntityId (vmwNsxTDataCenterStaticAddress) was re-added as BFD recovered. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTRoutingFeature 6 } -- ********************************************************** -- SecurityCompliance feature event notifications -- ********************************************************** vmwNsxTSecurityComplianceFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the SecurityCompliance feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 56 } vmwNsxTSecurityComplianceFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for SecurityCompliance feature notifications. " ::= { vmwNsxTSecurityComplianceFeaturePrefix 0 } vmwNsxTSecurityCompliancePollEAL4NonCompliance NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "One of the EAL4+ compliance requirements is being violated. That means the NSX configuration is currently non-compliant with regards to EAL4+. Action required: Run the compliance report from the UI Home - Monitoring & Dashboard - Compliance Report menu and resolve all the issues that are marked with the EAL4+ compliance name. " ::= { vmwNsxTSecurityComplianceFeature 1 } vmwNsxTSecurityCompliancePollEAL4NonComplianceClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The EAL4+ compliance issues have all been resolved. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTSecurityComplianceFeature 2 } vmwNsxTSecurityCompliancePollNDcPPNonCompliance NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "One of the NDcPP compliance requirements is being violated. That means the NSX configuration is currently non-compliant with regards to NDcPP. Action required: Run the compliance report from the UI Home - Monitoring & Dashboard - Compliance Report menu and resolve all the issues that are marked with the NDcPP compliance name. " ::= { vmwNsxTSecurityComplianceFeature 3 } vmwNsxTSecurityCompliancePollNDcPPNonComplianceClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The NDcPP compliance issues have all been resolved. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTSecurityComplianceFeature 4 } vmwNsxTSecurityComplianceTriggerEAL4NonCompliance NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "One of the EAL4+ compliance requirements is being violated. That means the NSX status is currently non-compliant with regards to EAL4+. Action required: Run the compliance report from the UI Home - Monitoring & Dashboard - Compliance Report menu and resolve all the issues that are marked with the EAL4+ compliance name. " ::= { vmwNsxTSecurityComplianceFeature 5 } vmwNsxTSecurityComplianceTriggerEAL4NonComplianceClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The EAL4+ compliance issues have all been resolved. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTSecurityComplianceFeature 6 } vmwNsxTSecurityComplianceTriggerNDcPPNonCompliance NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "One of the NDcPP compliance requirements is being violated. That means the NSX status is currently non-compliant with regards to NDcPP. Action required: Run the compliance report from the UI Home - Monitoring & Dashboard - Compliance Report menu and resolve all the issues that are marked with the NDcPP compliance name. " ::= { vmwNsxTSecurityComplianceFeature 7 } vmwNsxTSecurityComplianceTriggerNDcPPNonComplianceClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The NDcPP compliance issues have all been resolved. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTSecurityComplianceFeature 8 } -- ********************************************************** -- ServiceInsertion feature event notifications -- ********************************************************** vmwNsxTServiceInsertionFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the ServiceInsertion feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 14 } vmwNsxTServiceInsertionFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for ServiceInsertion feature notifications. " ::= { vmwNsxTServiceInsertionFeaturePrefix 0 } vmwNsxTServiceInsertionNewHostAdded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCentervCenterClusterId } STATUS current DESCRIPTION "New host added in cluster vmwNsxTDataCentervCenterClusterId and SVM will be deployed. Action required: Check for the VM deployment status and wait till it powers on. " ::= { vmwNsxTServiceInsertionFeature 7 } vmwNsxTServiceInsertionNewHostAddedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "New host added successfully. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTServiceInsertionFeature 8 } vmwNsxTServiceInsertionServiceChainPathDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Service chain path is down on vmwNsxTDataCenterEntityId and traffic flow is impacted. Action required: Perform any corrective action from the KB and check if the status is up. " ::= { vmwNsxTServiceInsertionFeature 21 } vmwNsxTServiceInsertionServiceChainPathDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Service chain path is up and configured as expected. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTServiceInsertionFeature 22 } vmwNsxTServiceInsertionServiceDeploymentFailed NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceName, vmwNsxTDataCentervCenterClusterId, vmwNsxTDataCenterFailureReason } STATUS current DESCRIPTION "The service deployment vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName on cluster vmwNsxTDataCentervCenterClusterId has failed. Reason : vmwNsxTDataCenterFailureReason Action required: Delete the service deployment using NSX UI or API. Perform any corrective action from the KB and retry service deployment again. " ::= { vmwNsxTServiceInsertionFeature 9 } vmwNsxTServiceInsertionServiceDeploymentFailedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The failed service deployment vmwNsxTDataCenterEntityId has been removed. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTServiceInsertionFeature 10 } vmwNsxTServiceInsertionServiceDeploymentSucceeded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceName, vmwNsxTDataCentervCenterClusterId } STATUS current DESCRIPTION "The service deployment vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName on cluster vmwNsxTDataCentervCenterClusterId has succeeded. Action required: No action needed. " ::= { vmwNsxTServiceInsertionFeature 11 } vmwNsxTServiceInsertionServiceDeploymentSucceededClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCentervCenterClusterId } STATUS current DESCRIPTION "The service deployment vmwNsxTDataCenterEntityId on cluster vmwNsxTDataCentervCenterClusterId has succeeded, no action needed. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTServiceInsertionFeature 12 } vmwNsxTServiceInsertionServiceInsertionInfraStatusDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTransportNodeId, vmwNsxTDataCenterFailureReason } STATUS current DESCRIPTION "SPF not enabled at port level on host vmwNsxTDataCenterTransportNodeId and the status is down. Reason : vmwNsxTDataCenterFailureReason. Action required: Perform any corrective action from the KB and check if the status is up. Resolve the alarm manually after checking the status. " ::= { vmwNsxTServiceInsertionFeature 29 } vmwNsxTServiceInsertionServiceInsertionInfraStatusDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Service insertion infrastructure status is up and has been correctly enabled on host. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTServiceInsertionFeature 30 } vmwNsxTServiceInsertionServiceUndeploymentFailed NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceName, vmwNsxTDataCentervCenterClusterId, vmwNsxTDataCenterFailureReason } STATUS current DESCRIPTION "The deletion of service deployment vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName on cluster vmwNsxTDataCentervCenterClusterId has failed. Reason : vmwNsxTDataCenterFailureReason Action required: Delete the service deployment using NSX UI or API. Perform any corrective action from the KB and retry deleting the service deployment again. Resolve the alarm manually after checking all the VM and objects are deleted. " ::= { vmwNsxTServiceInsertionFeature 15 } vmwNsxTServiceInsertionServiceUndeploymentFailedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The failed service deployment name vmwNsxTDataCenterEntityId has been removed. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTServiceInsertionFeature 16 } vmwNsxTServiceInsertionServiceUndeploymentSucceeded NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceName, vmwNsxTDataCentervCenterClusterId } STATUS current DESCRIPTION "The deletion of service deployment vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName on cluster vmwNsxTDataCentervCenterClusterId has succeeded. Action required: No action needed. " ::= { vmwNsxTServiceInsertionFeature 17 } vmwNsxTServiceInsertionServiceUndeploymentSucceededClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCentervCenterClusterId } STATUS current DESCRIPTION "The deletion of service deployment vmwNsxTDataCenterEntityId on cluster vmwNsxTDataCentervCenterClusterId has succeeded, no action needed. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTServiceInsertionFeature 18 } vmwNsxTServiceInsertionSVMHealthStatusDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceName, vmwNsxTDataCenterHostnameOrIPAddressWithPort, vmwNsxTDataCenterFailureReason } STATUS current DESCRIPTION "The health check for SVM vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName is not working correctly on vmwNsxTDataCenterHostnameOrIPAddressWithPort. Reason : vmwNsxTDataCenterFailureReason. Action required: Delete the service deployment using NSX UI or API. Perform any corrective action from the KB and retry service deployment again if necessary. " ::= { vmwNsxTServiceInsertionFeature 23 } vmwNsxTServiceInsertionSVMHealthStatusDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The SVM vmwNsxTDataCenterEntityId with wrong state has been removed. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTServiceInsertionFeature 24 } vmwNsxTServiceInsertionSVMHealthStatusUp NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceName, vmwNsxTDataCenterHostnameOrIPAddressWithPort } STATUS current DESCRIPTION "The health check for SVM vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName is working correctly on vmwNsxTDataCenterHostnameOrIPAddressWithPort. Action required: No action needed. " ::= { vmwNsxTServiceInsertionFeature 25 } vmwNsxTServiceInsertionSVMHealthStatusUpClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The SVM vmwNsxTDataCenterEntityId is working correctly, no action needed. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTServiceInsertionFeature 26 } vmwNsxTServiceInsertionSVMLivenessStateDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "SVM liveness state is down on vmwNsxTDataCenterEntityId and traffic flow is impacted. Action required: Perform any corrective action from the KB and check if the state is up. " ::= { vmwNsxTServiceInsertionFeature 27 } vmwNsxTServiceInsertionSVMLivenessStateDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "SVM liveness state is up and configured as expected. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTServiceInsertionFeature 28 } -- ********************************************************** -- TEPHealth feature event notifications -- ********************************************************** vmwNsxTTEPHealthFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the TEPHealth feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 51 } vmwNsxTTEPHealthFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for TEPHealth feature notifications. " ::= { vmwNsxTTEPHealthFeaturePrefix 0 } vmwNsxTTEPHealthFaultyTEP NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId, vmwNsxTDataCenterVtepFaultReason } STATUS current DESCRIPTION "TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId. Overlay workloads using this TEP will face network outage. Reason: vmwNsxTDataCenterVtepFaultReason. Action required: 1. Check if TEP has valid IP or any other underlay connectivity issues. 2. Enable TEP HA to failover workloads to other healthy TEPs. " ::= { vmwNsxTTEPHealthFeature 1 } vmwNsxTTEPHealthFaultyTEPClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId is healthy. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTTEPHealthFeature 2 } vmwNsxTTEPHealthFaultyTEPOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId, vmwNsxTDataCenterDPUId, vmwNsxTDataCenterVtepFaultReason } STATUS current DESCRIPTION "TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId. Overlay workloads using this TEP will face network outage. Reason: vmwNsxTDataCenterVtepFaultReason. Action required: 1. Check if TEP has valid IP or any other underlay connectivity issues. 2. Enable TEP HA to failover workloads to other healthy TEPs. " ::= { vmwNsxTTEPHealthFeature 3 } vmwNsxTTEPHealthFaultyTEPOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId is healthy. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTTEPHealthFeature 4 } vmwNsxTTEPHealthTEPAutorecoverFailure NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId failed. Overlay workloads using this TEP will failover to other healthy TEPs. If no other healthy TEPs, overlay workloads will face network outage. Action required: Check if TEP has valid IP or any other underlay connectivity issues. " ::= { vmwNsxTTEPHealthFeature 5 } vmwNsxTTEPHealthTEPAutorecoverFailureClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId is cleared. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTTEPHealthFeature 6 } vmwNsxTTEPHealthTEPAutorecoverFailureOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId failed. Overlay workloads using this TEP will failover to other healthy TEPs. If no other healthy TEPs, overlay workloads will face network outage. Action required: Check if TEP has valid IP or any other underlay connectivity issues. " ::= { vmwNsxTTEPHealthFeature 7 } vmwNsxTTEPHealthTEPAutorecoverFailureOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId is cleared. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTTEPHealthFeature 8 } vmwNsxTTEPHealthTEPAutorecoverSuccess NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId is successful. Action required: None. " ::= { vmwNsxTTEPHealthFeature 9 } vmwNsxTTEPHealthTEPAutorecoverSuccessClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId is cleared. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTTEPHealthFeature 10 } vmwNsxTTEPHealthTEPAutorecoverSuccessOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId. on DPU vmwNsxTDataCenterDPUId is successful. Action required: None. " ::= { vmwNsxTTEPHealthFeature 11 } vmwNsxTTEPHealthTEPAutorecoverSuccessOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId. on DPU vmwNsxTDataCenterDPUId is cleared. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTTEPHealthFeature 12 } vmwNsxTTEPHealthTEPHaActivated NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "TEP HA activated for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId. Action required: Enable AutoRecover or invoke Manual Recover for TEP:vmwNsxTDataCenterVtepName on VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId. " ::= { vmwNsxTTEPHealthFeature 13 } vmwNsxTTEPHealthTEPHaActivatedClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "TEP HA cleared for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTTEPHealthFeature 14 } vmwNsxTTEPHealthTEPHaActivatedOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "TEP HA activated for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId. Action required: Enable AutoRecover or invoke Manual Recover for TEP:vmwNsxTDataCenterVtepName on VDS:vmwNsxTDataCenterDvsName. at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId. " ::= { vmwNsxTTEPHealthFeature 15 } vmwNsxTTEPHealthTEPHaActivatedOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterVtepName, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterTransportNodeId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "TEP HA cleared for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTTEPHealthFeature 16 } -- ********************************************************** -- TransportNodeHealth feature event notifications -- ********************************************************** vmwNsxTTransportNodeHealthFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the TransportNodeHealth feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 18 } vmwNsxTTransportNodeHealthFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for TransportNodeHealth feature notifications. " ::= { vmwNsxTTransportNodeHealthFeaturePrefix 0 } vmwNsxTTransportNodeHealthLAGMemberDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "LACP reporting member down. Action required: Check the connection status of LAG members on hosts. 1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes | Host Transport Nodes. 2. In the Host Transport Nodes list, check the Node Status column. Find the Transport node with the degraded or down Node Status. 3. Select | Monitor. Find the bond(uplink) which is reporting degraded or down. 4. Check the LACP member status details by logging into the failed host and invoking `esxcli network vswitch dvs vmware lacp status get` on an ESXi host or `ovs-appctl bond/show` and `ovs-appctl lacp/show` on a KVM host. " ::= { vmwNsxTTransportNodeHealthFeature 5 } vmwNsxTTransportNodeHealthLAGMemberDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "LACP reporting member up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTTransportNodeHealthFeature 6 } vmwNsxTTransportNodeHealthLAGMemberDownOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "LACP on DPU vmwNsxTDataCenterDPUId reporting member down. Action required: Check the connection status of LAG members on DPU vmwNsxTDataCenterDPUId. Find out the mapped name of related physical NIC on host, then perform checking on UI. 1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes | Host Transport Nodes. 2. In the Host Transport Nodes list, check the Node Status column. Find the Transport node with the degraded or down Node Status. 3. Select | Monitor. Find the bond(uplink) which is reporting degraded or down. 4. Check the LACP member status details by logging into the failed DPU vmwNsxTDataCenterDPUId and invoking `esxcli network vswitch dvs vmware lacp status get`. " ::= { vmwNsxTTransportNodeHealthFeature 9 } vmwNsxTTransportNodeHealthLAGMemberDownOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "LACP on DPU vmwNsxTDataCenterDPUId reporting member up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTTransportNodeHealthFeature 10 } vmwNsxTTransportNodeHealthNVDSUplinkDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Uplink is going down. Action required: Check the physical NICs' status of uplinks on hosts. 1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes | Host Transport Nodes. 2. In the Host Transport Nodes list, check the Node Status column. Find the Transport node with the degraded or down Node Status. 3. Select | Monitor. Check the status details of the bond(uplink) which is reporting degraded or down. To avoid a degraded state, ensure all uplink interfaces are connected and up regardless of whether they are in use or not. " ::= { vmwNsxTTransportNodeHealthFeature 3 } vmwNsxTTransportNodeHealthNVDSUplinkDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Uplink is going up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTTransportNodeHealthFeature 4 } vmwNsxTTransportNodeHealthTransportNodeUplinkDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Uplink is going down. Action required: Check the physical NICs' status of uplinks on hosts. 1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes | Host Transport Nodes. 2. In the Host Transport Nodes list, check the Node Status column. Find the Transport node with the degraded or down Node Status. 3. Select | Monitor. Check the status details of the bond(uplink) which is reporting degraded or down. To avoid a degraded state, ensure all uplink interfaces are connected and up regardless of whether they are in use or not. " ::= { vmwNsxTTransportNodeHealthFeature 7 } vmwNsxTTransportNodeHealthTransportNodeUplinkDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Uplink is going up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTTransportNodeHealthFeature 8 } vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPU NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "Uplink on DPU vmwNsxTDataCenterDPUId is going down. Action required: Check the physical NICs' status of uplinks on DPU vmwNsxTDataCenterDPUId. Find out the mapped name of this physical NIC on host, then perform checking on UI. 1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes | Host Transport Nodes. 2. In the Host Transport Nodes list, check the Node Status column. Find the Transport node with the degraded or down Node Status. 3. Select | Monitor. Check the status details of the bond(uplink) which is reporting degraded or down. To avoid a degraded state, ensure all uplink interfaces are connected and up regardless of whether they are in use or not. " ::= { vmwNsxTTransportNodeHealthFeature 11 } vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPUClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterDPUId } STATUS current DESCRIPTION "Uplink on DPU vmwNsxTDataCenterDPUId is going up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTTransportNodeHealthFeature 12 } -- ********************************************************** -- VMCApp feature event notifications -- ********************************************************** vmwNsxTVMCAppFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the VMCApp feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 50 } vmwNsxTVMCAppFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for VMCApp feature notifications. " ::= { vmwNsxTVMCAppFeaturePrefix 0 } vmwNsxTVMCAppTransitConnectFailure NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Transit Connect related configuration is not fully correctly realized. Possible issues could be failing to retrieve provider information or some transient provider communication error. Action required: If this alarm is not auto-resolved within 10 minutes, retry the most recent transit connect related request(s). For example, if a TGW attachment API request triggered this alarm, retry the TGW attachment API request again. If alarm does not resolve even after retry, then try the following steps: 1. Check if the task keeps failing, or the task has recovered. a) Identify leader Manager node. After logging into one of the nodes, run command: - `su admin` - `get cluster status verbose` This will show the leader Manager node b) Log in to NSX leader Manager node. check vmc-app.log on the NSX leader Manager node: - `tail -f /var/log/policy/vmc-app.log` c) Check logs for following prints - If any of these error messages keeps showing every two mins, that means task keeps failing. - Failed to get TGW route table for []. Error: [] - Failed to get TGW routes for attachment [] in route table []. Error - Failed to get TGW attachment VPC ID for []. Error: [] - Failed to get TGW attachment resource ID for []. Error: Unknown resource type - Failed to get TGW attachments for TGW []. Error: [] - Failed to get local TGW attachment []. Error: [] - Failed to find correct TgwAttachment state in AWS, state: [], skipping TGW route update task - TGW attachment [] is not associated with any route table - No local TGW SDDC attachment found for [] 2. Check if all AWS calls from NSX Manager failed, on leader Manager node. Run following command: - `export HTTP_PROXY=http://:3128` - `export HTTPS_PROXY=http://:3128` - `export NO_PROXY=169.254.169.254` - `aws ec2 describe-instances --region ` If aws command failed with error, then there might be a system issue in HTTP reverse proxy configuration on pop, or there is AWS service side issue. 3. Check whether TGW attachment still exists in AWS. a) TGW attachment ID could be found with GET cloud-service/api/v1/infra/associated-groups - `aws ec2 describe-transit-gateway-attachments --region --transit-gateway-attachment-id ` If TGW attachment has been deleted, contact VMware Support, share SDDC ID and TGW attachment ID. After VMware support team identified the issue, manually delete the object left behind, if needed. b) Check if this TGW attachment exists on AWS console. c) Another option is logging in to NSX Manager, using aws command to check the state of TGW attachment: - `aws ec2 describe-transit-gateway-attachments --region --transit-gateway-attachment-id ` " ::= { vmwNsxTVMCAppFeature 1 } vmwNsxTVMCAppTransitConnectFailureClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "Transit Connect failure is remediated. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTVMCAppFeature 2 } -- ********************************************************** -- VPN feature event notifications -- ********************************************************** vmwNsxTVPNFeaturePrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications applicable to the VPN feature have this OID prefix." ::= { vmwNsxTDataCenterNotifications 15 } vmwNsxTVPNFeature OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-identifier added to ensure the next-to-last sub-identifier is zero for VPN feature notifications. " ::= { vmwNsxTVPNFeaturePrefix 0 } vmwNsxTVPNIPsecPolicyBasedSessionDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSessionDownReason } STATUS current DESCRIPTION "The policy based IPsec VPN session vmwNsxTDataCenterEntityId is down. Reason: vmwNsxTDataCenterSessionDownReason. Action required: Check IPsec VPN session configuration and resolve errors based on the session down reason. " ::= { vmwNsxTVPNFeature 7 } vmwNsxTVPNIPsecPolicyBasedSessionDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The policy based IPsec VPN session vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTVPNFeature 8 } vmwNsxTVPNIPsecPolicyBasedTunnelDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "One or more policy based IPsec VPN tunnels in session vmwNsxTDataCenterEntityId are down. Action required: Check IPsec VPN session configuration and resolve errors based on the tunnel down reason. " ::= { vmwNsxTVPNFeature 9 } vmwNsxTVPNIPsecPolicyBasedTunnelDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "All policy based IPsec VPN tunnels in session vmwNsxTDataCenterEntityId are up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTVPNFeature 10 } vmwNsxTVPNIPsecRouteBasedSessionDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterSessionDownReason } STATUS current DESCRIPTION "The route based IPsec VPN session vmwNsxTDataCenterEntityId is down. Reason: vmwNsxTDataCenterSessionDownReason. Action required: Check IPsec VPN session configuration and resolve errors based on the session down reason. " ::= { vmwNsxTVPNFeature 11 } vmwNsxTVPNIPsecRouteBasedSessionDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The route based IPsec VPN session vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTVPNFeature 12 } vmwNsxTVPNIPsecRouteBasedTunnelDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterTunnelDownReason } STATUS current DESCRIPTION "The route based IPsec VPN tunnel in session vmwNsxTDataCenterEntityId is down. Reason: vmwNsxTDataCenterTunnelDownReason. Action required: Check IPsec VPN session configuration and resolve errors based on the tunnel down reason. " ::= { vmwNsxTVPNFeature 13 } vmwNsxTVPNIPsecRouteBasedTunnelDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The route based IPsec VPN tunnel in session vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTVPNFeature 14 } vmwNsxTVPNIPsecServiceDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterServiceDownReason } STATUS current DESCRIPTION "The IPsec service vmwNsxTDataCenterEntityId is down. Reason: vmwNsxTDataCenterServiceDownReason. Action required: 1. Disable and enable the IPsec service from NSX Manager UI. 2. If the issue still persists, check syslog for error logs and contact VMware support. " ::= { vmwNsxTVPNFeature 17 } vmwNsxTVPNIPsecServiceDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The IPsec service vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTVPNFeature 18 } vmwNsxTVPNL2VpnSessionDown NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The L2VPN session vmwNsxTDataCenterEntityId is down. Action required: Check L2VPN session status for session down reason and resolve errors based on the reason. " ::= { vmwNsxTVPNFeature 15 } vmwNsxTVPNL2VpnSessionDownClear NOTIFICATION-TYPE OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterEntityId } STATUS current DESCRIPTION "The L2VPN session vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared. " ::= { vmwNsxTVPNFeature 16 } -- ********************************************************** -- Conformance information -- ********************************************************** vmwNsxTDataCenterConformance OBJECT IDENTIFIER ::= { vmwNSXsysMIB 2 } vmwNsxTDataCenterCompliances OBJECT IDENTIFIER ::= { vmwNsxTDataCenterConformance 1 } vmwNsxTDataCenterSMIBGroups OBJECT IDENTIFIER ::= { vmwNsxTDataCenterConformance 2 } -- ********************************************************** -- Compliance statements -- ********************************************************** vmwNsxTDataCenterBasicCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxTDataCenterNotificationInfoGroup, vmwNsxTDataCenterNotificationGroup } ::= { vmwNsxTDataCenterCompliances 1 } vmwNsxTDataCenterNotificationInfoGroup OBJECT-GROUP OBJECTS { vmwNsxTDataCenterTimestamp, vmwNsxTDataCenterFeatureName, vmwNsxTDataCenterEventType, vmwNsxTDataCenterEventSeverity, vmwNsxTDataCenterNodeId, vmwNsxTDataCenterNodeType, vmwNsxTDataCenterApplianceAddress, vmwNsxTDataCenterBGPNeighborIP, vmwNsxTDataCenterCurrentGatewayState, vmwNsxTDataCenterCurrentServiceState, vmwNsxTDataCenterDHCPPoolUsage, vmwNsxTDataCenterDHCPServerId, vmwNsxTDataCenterDatapathResourceUsage, vmwNsxTDataCenterDiskPartitionName, vmwNsxTDataCenterDuplicateIPAddress, vmwNsxTDataCenterEdgeNICName, vmwNsxTDataCenterEdgeServiceName, vmwNsxTDataCenterEntityId, vmwNsxTDataCenterEventId, vmwNsxTDataCenterFailureReason, vmwNsxTDataCenterHeapType, vmwNsxTDataCenterIntelligenceNodeId, vmwNsxTDataCenterLicenseEditionType, vmwNsxTDataCenterMempoolName, vmwNsxTDataCenterPasswordExpirationDays, vmwNsxTDataCenterPeerAddress, vmwNsxTDataCenterPreviousGatewayState, vmwNsxTDataCenterPreviousServiceState, vmwNsxTDataCenterRxRingBufferOverflowPercentage, vmwNsxTDataCenterServiceName, vmwNsxTDataCenterSessionDownReason, vmwNsxTDataCenterSrId, vmwNsxTDataCenterStaticAddress, vmwNsxTDataCenterSystemResourceUsage, vmwNsxTDataCenterSystemUsageThreshold, vmwNsxTDataCenterTunnelDownReason, vmwNsxTDataCenterTxRingBufferOverflowPercentage, vmwNsxTDataCenterUsername } STATUS current DESCRIPTION "These objects provide details in NSX Data Center event notifications." ::= { vmwNsxTDataCenterSMIBGroups 1 } vmwNsxTDataCenterNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { vmwNsxTAlarmManagementAlarmServiceOverloaded, vmwNsxTAlarmManagementAlarmServiceOverloadedClear, vmwNsxTAlarmManagementHeavyVolumeOfAlarms, vmwNsxTAlarmManagementHeavyVolumeOfAlarmsClear, vmwNsxTCertificatesCertificateExpirationApproaching, vmwNsxTCertificatesCertificateExpirationApproachingClear, vmwNsxTCertificatesCertificateExpired, vmwNsxTCertificatesCertificateExpiredClear, vmwNsxTCertificatesCertificateIsAboutToExpire, vmwNsxTCertificatesCertificateIsAboutToExpireClear, vmwNsxTCniHealthHyperbusManagerConnectionDown, vmwNsxTCniHealthHyperbusManagerConnectionDownClear, vmwNsxTDHCPPoolLeaseAllocationFailed, vmwNsxTDHCPPoolLeaseAllocationFailedClear, vmwNsxTDHCPPoolOverloaded, vmwNsxTDHCPPoolOverloadedClear, vmwNsxTDistributedFirewallDFWCPUUsageVeryHigh, vmwNsxTDistributedFirewallDFWCPUUsageVeryHighClear, vmwNsxTDistributedFirewallDFWMemoryUsageVeryHigh, vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighClear, vmwNsxTDNSForwarderDisabled, vmwNsxTDNSForwarderDisabledClear, vmwNsxTDNSForwarderDown, vmwNsxTDNSForwarderDownClear, vmwNsxTEdgeHealthEdgeCPUUsageHigh, vmwNsxTEdgeHealthEdgeCPUUsageHighClear, vmwNsxTEdgeHealthEdgeCPUUsageVeryHigh, vmwNsxTEdgeHealthEdgeCPUUsageVeryHighClear, vmwNsxTEdgeHealthEdgeDatapathConfigurationFailure, vmwNsxTEdgeHealthEdgeDatapathConfigurationFailureClear, vmwNsxTEdgeHealthEdgeDatapathCPUHigh, vmwNsxTEdgeHealthEdgeDatapathCPUHighClear, vmwNsxTEdgeHealthEdgeDatapathCPUVeryHigh, vmwNsxTEdgeHealthEdgeDatapathCPUVeryHighClear, vmwNsxTEdgeHealthEdgeDatapathCryptodrvDown, vmwNsxTEdgeHealthEdgeDatapathCryptodrvDownClear, vmwNsxTEdgeHealthEdgeDatapathMempoolHigh, vmwNsxTEdgeHealthEdgeDatapathMempoolHighClear, vmwNsxTEdgeHealthEdgeDiskUsageHigh, vmwNsxTEdgeHealthEdgeDiskUsageHighClear, vmwNsxTEdgeHealthEdgeDiskUsageVeryHigh, vmwNsxTEdgeHealthEdgeDiskUsageVeryHighClear, vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHigh, vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHighClear, vmwNsxTEdgeHealthEdgeMemoryUsageHigh, vmwNsxTEdgeHealthEdgeMemoryUsageHighClear, vmwNsxTEdgeHealthEdgeMemoryUsageVeryHigh, vmwNsxTEdgeHealthEdgeMemoryUsageVeryHighClear, vmwNsxTEdgeHealthEdgeNICLinkStatusDown, vmwNsxTEdgeHealthEdgeNICLinkStatusDownClear, vmwNsxTEdgeHealthEdgeNICOutOfReceiveBuffer, vmwNsxTEdgeHealthEdgeNICOutOfReceiveBufferClear, vmwNsxTEdgeHealthEdgeNICOutOfTransmitBuffer, vmwNsxTEdgeHealthEdgeNICOutOfTransmitBufferClear, vmwNsxTEndpointProtectionEAMStatusDown, vmwNsxTEndpointProtectionEAMStatusDownClear, vmwNsxTEndpointProtectionPartnerChannelDown, vmwNsxTEndpointProtectionPartnerChannelDownClear, vmwNsxTHighAvailabilityTier0GatewayFailover, vmwNsxTHighAvailabilityTier0GatewayFailoverClear, vmwNsxTHighAvailabilityTier1GatewayFailover, vmwNsxTHighAvailabilityTier1GatewayFailoverClear, vmwNsxTInfrastructureCommunicationEdgeTunnelsDown, vmwNsxTInfrastructureCommunicationEdgeTunnelsDownClear, vmwNsxTInfrastructureServiceEdgeServiceStatusChanged, vmwNsxTInfrastructureServiceEdgeServiceStatusChangedClear, vmwNsxTInfrastructureServiceEdgeServiceStatusDown, vmwNsxTInfrastructureServiceEdgeServiceStatusDownClear, vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnected, vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnectedClear, vmwNsxTIntelligenceHealthCPUUsageHigh, vmwNsxTIntelligenceHealthCPUUsageHighClear, vmwNsxTIntelligenceHealthCPUUsageVeryHigh, vmwNsxTIntelligenceHealthCPUUsageVeryHighClear, vmwNsxTIntelligenceHealthDataDiskPartitionUsageHigh, vmwNsxTIntelligenceHealthDataDiskPartitionUsageHighClear, vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHigh, vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHighClear, vmwNsxTIntelligenceHealthDiskUsageHigh, vmwNsxTIntelligenceHealthDiskUsageHighClear, vmwNsxTIntelligenceHealthDiskUsageVeryHigh, vmwNsxTIntelligenceHealthDiskUsageVeryHighClear, vmwNsxTIntelligenceHealthMemoryUsageHigh, vmwNsxTIntelligenceHealthMemoryUsageHighClear, vmwNsxTIntelligenceHealthMemoryUsageVeryHigh, vmwNsxTIntelligenceHealthMemoryUsageVeryHighClear, vmwNsxTIntelligenceHealthNodeStatusDegraded, vmwNsxTIntelligenceHealthNodeStatusDegradedClear, vmwNsxTLicensesLicenseExpired, vmwNsxTLicensesLicenseExpiredClear, vmwNsxTLicensesLicenseIsAboutToExpire, vmwNsxTLicensesLicenseIsAboutToExpireClear, vmwNsxTLoadBalancerLBCPUVeryHigh, vmwNsxTLoadBalancerLBCPUVeryHighClear, vmwNsxTLoadBalancerLBStatusDown, vmwNsxTLoadBalancerLBStatusDownClear, vmwNsxTLoadBalancerPoolStatusDown, vmwNsxTLoadBalancerPoolStatusDownClear, vmwNsxTLoadBalancerVirtualServerStatusDown, vmwNsxTLoadBalancerVirtualServerStatusDownClear, vmwNsxTManagerHealthDuplicateIPAddress, vmwNsxTManagerHealthDuplicateIPAddressClear, vmwNsxTManagerHealthManagerConfigDiskUsageHigh, vmwNsxTManagerHealthManagerConfigDiskUsageHighClear, vmwNsxTManagerHealthManagerConfigDiskUsageVeryHigh, vmwNsxTManagerHealthManagerConfigDiskUsageVeryHighClear, vmwNsxTManagerHealthManagerCPUUsageHigh, vmwNsxTManagerHealthManagerCPUUsageHighClear, vmwNsxTManagerHealthManagerCPUUsageVeryHigh, vmwNsxTManagerHealthManagerCPUUsageVeryHighClear, vmwNsxTManagerHealthManagerDiskUsageHigh, vmwNsxTManagerHealthManagerDiskUsageHighClear, vmwNsxTManagerHealthManagerDiskUsageVeryHigh, vmwNsxTManagerHealthManagerDiskUsageVeryHighClear, vmwNsxTManagerHealthManagerMemoryUsageHigh, vmwNsxTManagerHealthManagerMemoryUsageHighClear, vmwNsxTManagerHealthManagerMemoryUsageVeryHigh, vmwNsxTManagerHealthManagerMemoryUsageVeryHighClear, vmwNsxTNCPHealthNCPPluginDown, vmwNsxTNCPHealthNCPPluginDownClear, vmwNsxTNodeAgentsHealthNodeAgentsDown, vmwNsxTNodeAgentsHealthNodeAgentsDownClear, vmwNsxTPasswordManagementPasswordExpirationApproaching, vmwNsxTPasswordManagementPasswordExpirationApproachingClear, vmwNsxTPasswordManagementPasswordExpired, vmwNsxTPasswordManagementPasswordExpiredClear, vmwNsxTPasswordManagementPasswordIsAboutToExpire, vmwNsxTPasswordManagementPasswordIsAboutToExpireClear, vmwNsxTRoutingBFDDownOnExternalInterface, vmwNsxTRoutingBFDDownOnExternalInterfaceClear, vmwNsxTRoutingBGPDown, vmwNsxTRoutingBGPDownClear, vmwNsxTRoutingRoutingDown, vmwNsxTRoutingRoutingDownClear, vmwNsxTRoutingStaticRoutingRemoved, vmwNsxTRoutingStaticRoutingRemovedClear, vmwNsxTTransportNodeHealthLAGMemberDown, vmwNsxTTransportNodeHealthLAGMemberDownClear, vmwNsxTTransportNodeHealthNVDSUplinkDown, vmwNsxTTransportNodeHealthNVDSUplinkDownClear, vmwNsxTVPNIPsecPolicyBasedSessionDown, vmwNsxTVPNIPsecPolicyBasedSessionDownClear, vmwNsxTVPNIPsecPolicyBasedTunnelDown, vmwNsxTVPNIPsecPolicyBasedTunnelDownClear, vmwNsxTVPNIPsecRouteBasedSessionDown, vmwNsxTVPNIPsecRouteBasedSessionDownClear, vmwNsxTVPNIPsecRouteBasedTunnelDown, vmwNsxTVPNIPsecRouteBasedTunnelDownClear, vmwNsxTVPNL2VpnSessionDown, vmwNsxTVPNL2VpnSessionDownClear } STATUS current DESCRIPTION "Group of objects describing event notifications emitted by NSX Data Center. " ::= { vmwNsxTDataCenterSMIBGroups 2 } vmwNsxTDataCenterBasicCompliance2 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxTDataCenterNotificationInfoGroup, vmwNsxTDataCenterNotificationInfoGroup2, vmwNsxTDataCenterNotificationGroup, vmwNsxTDataCenterNotificationGroup2 } ::= { vmwNsxTDataCenterCompliances 2 } vmwNsxTDataCenterNotificationInfoGroup2 OBJECT-GROUP OBJECTS { vmwNsxTDataCenterBGPSourceIP, vmwNsxTDataCenterRemoteSiteId, vmwNsxTDataCenterRemoteSiteName, vmwNsxTDataCenterSiteId, vmwNsxTDataCenterSiteName } STATUS current DESCRIPTION "These objects provide details in NSX Data Center event notifications." ::= { vmwNsxTDataCenterSMIBGroups 3 } vmwNsxTDataCenterNotificationGroup2 NOTIFICATION-GROUP NOTIFICATIONS { vmwNsxTEdgeHealthStorageError, vmwNsxTEdgeHealthStorageErrorClear, vmwNsxTFederationLmToLmSynchronizationError, vmwNsxTFederationLmToLmSynchronizationErrorClear, vmwNsxTFederationLmToLmSynchronizationWarning, vmwNsxTFederationLmToLmSynchronizationWarningClear, vmwNsxTFederationRtepBGPDown, vmwNsxTFederationRtepBGPDownClear, vmwNsxTManagerHealthOperationsDbDiskUsageHigh, vmwNsxTManagerHealthOperationsDbDiskUsageHighClear, vmwNsxTManagerHealthOperationsDbDiskUsageVeryHigh, vmwNsxTManagerHealthOperationsDbDiskUsageVeryHighClear } STATUS current DESCRIPTION "Group of objects describing event notifications emitted by NSX Data Center. " ::= { vmwNsxTDataCenterSMIBGroups 4 } vmwNsxTDataCenterBasicCompliance3 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxTDataCenterNotificationInfoGroup, vmwNsxTDataCenterNotificationInfoGroup2, vmwNsxTDataCenterNotificationInfoGroup3, vmwNsxTDataCenterNotificationGroup, vmwNsxTDataCenterNotificationGroup2, vmwNsxTDataCenterNotificationGroup3 } ::= { vmwNsxTDataCenterCompliances 3 } vmwNsxTDataCenterNotificationInfoGroup3 OBJECT-GROUP OBJECTS { vmwNsxTDataCenterLrId, vmwNsxTDataCenterManagerNodeName, vmwNsxTDataCenterRxMisses, vmwNsxTDataCenterRxProcessed, vmwNsxTDataCenterTransportNodeAddress, vmwNsxTDataCenterTransportNodeName, vmwNsxTDataCenterTxMisses, vmwNsxTDataCenterTxProcessed } STATUS current DESCRIPTION "These objects provide details in NSX Data Center event notifications." ::= { vmwNsxTDataCenterSMIBGroups 5 } vmwNsxTDataCenterNotificationGroup3 NOTIFICATION-GROUP NOTIFICATIONS { vmwNsxTCommunicationManagementChannelToTransportNodeDown, vmwNsxTCommunicationManagementChannelToTransportNodeDownClear, vmwNsxTCommunicationManagementChannelToTransportNodeDownLg, vmwNsxTCommunicationManagementChannelToTransportNodeDownLgClear, vmwNsxTCommunicationManagerControlChannelDown, vmwNsxTCommunicationManagerControlChannelDownClear, vmwNsxTFederationRtepConnectivityLost, vmwNsxTFederationRtepConnectivityLostClear, vmwNsxTManagerHealthStorageError, vmwNsxTManagerHealthStorageErrorClear } STATUS current DESCRIPTION "Group of objects describing event notifications emitted by NSX Data Center. " ::= { vmwNsxTDataCenterSMIBGroups 6 } vmwNsxTDataCenterBasicCompliance4 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxTDataCenterNotificationInfoGroup, vmwNsxTDataCenterNotificationInfoGroup2, vmwNsxTDataCenterNotificationInfoGroup3, vmwNsxTDataCenterNotificationInfoGroup4, vmwNsxTDataCenterNotificationGroup, vmwNsxTDataCenterNotificationGroup2, vmwNsxTDataCenterNotificationGroup3, vmwNsxTDataCenterNotificationGroup4 } ::= { vmwNsxTDataCenterCompliances 4 } vmwNsxTDataCenterNotificationInfoGroup4 OBJECT-GROUP OBJECTS { vmwNsxTDataCenterActiveGlobalManager, vmwNsxTDataCenterActiveGlobalManagers, vmwNsxTDataCenterApplianceFQDN, vmwNsxTDataCenterCapacityDisplayName, vmwNsxTDataCenterCapacityUsageCount, vmwNsxTDataCenterCentralControlPlaneId, vmwNsxTDataCenterDirectoryDomain, vmwNsxTDataCenterDisplayedLicenseKey, vmwNsxTDataCenterEdgeThreadName, vmwNsxTDataCenterHostnameOrIPAddressWithPort, vmwNsxTDataCenterIDSEventsCount, vmwNsxTDataCenterLDAPServer, vmwNsxTDataCenterLatencySource, vmwNsxTDataCenterLatencyThreshold, vmwNsxTDataCenterLatencyValue, vmwNsxTDataCenterManagerNodeId, vmwNsxTDataCenterMaxCapacityThreshold, vmwNsxTDataCenterMaxIDSEventsAllowed, vmwNsxTDataCenterMaxSupportedCapacityCount, vmwNsxTDataCenterMinCapacityThreshold, vmwNsxTDataCenterRemoteApplianceAddress, vmwNsxTDataCenterRemoteManagerNodeId, vmwNsxTDataCenterTimeoutInMinutes } STATUS current DESCRIPTION "These objects provide details in NSX Data Center event notifications." ::= { vmwNsxTDataCenterSMIBGroups 7 } vmwNsxTDataCenterNotificationGroup4 NOTIFICATION-GROUP NOTIFICATIONS { vmwNsxTAuditLogHealthAuditLogFileUpdateError, vmwNsxTAuditLogHealthAuditLogFileUpdateErrorClear, vmwNsxTAuditLogHealthRemoteLoggingServerError, vmwNsxTAuditLogHealthRemoteLoggingServerErrorClear, vmwNsxTCapacityMaximumCapacity, vmwNsxTCapacityMaximumCapacityClear, vmwNsxTCapacityMaximumCapacityThreshold, vmwNsxTCapacityMaximumCapacityThresholdClear, vmwNsxTCapacityMinimumCapacityThreshold, vmwNsxTCapacityMinimumCapacityThresholdClear, vmwNsxTCommunicationControlChannelToManagerNodeDown, vmwNsxTCommunicationControlChannelToManagerNodeDownClear, vmwNsxTCommunicationControlChannelToManagerNodeDownTooLong, vmwNsxTCommunicationControlChannelToManagerNodeDownTooLongClear, vmwNsxTCommunicationControlChannelToTransportNodeDown, vmwNsxTCommunicationControlChannelToTransportNodeDownClear, vmwNsxTCommunicationControlChannelToTransportNodeDownLong, vmwNsxTCommunicationControlChannelToTransportNodeDownLongClear, vmwNsxTCommunicationManagerClusterLatencyHigh, vmwNsxTCommunicationManagerClusterLatencyHighClear, vmwNsxTCommunicationManagerFQDNLookupFailure, vmwNsxTCommunicationManagerFQDNLookupFailureClear, vmwNsxTCommunicationManagerFQDNReverseLookupFailure, vmwNsxTCommunicationManagerFQDNReverseLookupFailureClear, vmwNsxTDistributedIDSIPSMaxEventsReached, vmwNsxTDistributedIDSIPSMaxEventsReachedClear, vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHigh, vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHighClear, vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHigh, vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHighClear, vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHigh, vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHighClear, vmwNsxTDistributedIDSIPSNSXIDPSEngineDown, vmwNsxTDistributedIDSIPSNSXIDPSEngineDownClear, vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHigh, vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighClear, vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHigh, vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHighClear, vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHigh, vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHighClear, vmwNsxTEdgeHealthDatapathThreadDeadlocked, vmwNsxTEdgeHealthDatapathThreadDeadlockedClear, vmwNsxTFederationGMToGMSplitBrain, vmwNsxTFederationGMToGMSplitBrainClear, vmwNsxTIdentityFirewallConnectivityToLDAPServerLost, vmwNsxTIdentityFirewallConnectivityToLDAPServerLostClear, vmwNsxTIdentityFirewallErrorInDeltaSync, vmwNsxTIdentityFirewallErrorInDeltaSyncClear, vmwNsxTInfrastructureServiceServiceStatusUnknown, vmwNsxTInfrastructureServiceServiceStatusUnknownClear, vmwNsxTIntelligenceHealthStorageLatencyHigh, vmwNsxTIntelligenceHealthStorageLatencyHighClear } STATUS current DESCRIPTION "Group of objects describing event notifications emitted by NSX Data Center. " ::= { vmwNsxTDataCenterSMIBGroups 8 } vmwNsxTDataCenterBasicCompliance5 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxTDataCenterNotificationInfoGroup, vmwNsxTDataCenterNotificationInfoGroup2, vmwNsxTDataCenterNotificationInfoGroup3, vmwNsxTDataCenterNotificationInfoGroup4, vmwNsxTDataCenterNotificationGroup, vmwNsxTDataCenterNotificationGroup2, vmwNsxTDataCenterNotificationGroup3, vmwNsxTDataCenterNotificationGroup4, vmwNsxTDataCenterNotificationGroup5 } ::= { vmwNsxTDataCenterCompliances 5 } vmwNsxTDataCenterNotificationGroup5 NOTIFICATION-GROUP NOTIFICATIONS { vmwNsxTRoutingOSPFNeighborWentDown, vmwNsxTRoutingOSPFNeighborWentDownClear } STATUS current DESCRIPTION "Group of objects describing event notifications emitted by NSX Data Center. " ::= { vmwNsxTDataCenterSMIBGroups 10 } vmwNsxTDataCenterBasicCompliance6 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxTDataCenterNotificationInfoGroup, vmwNsxTDataCenterNotificationInfoGroup2, vmwNsxTDataCenterNotificationInfoGroup3, vmwNsxTDataCenterNotificationInfoGroup4, vmwNsxTDataCenterNotificationInfoGroup6, vmwNsxTDataCenterNotificationGroup, vmwNsxTDataCenterNotificationGroup2, vmwNsxTDataCenterNotificationGroup3, vmwNsxTDataCenterNotificationGroup4, vmwNsxTDataCenterNotificationGroup5, vmwNsxTDataCenterNotificationGroup6 } ::= { vmwNsxTDataCenterCompliances 6 } vmwNsxTDataCenterNotificationInfoGroup6 OBJECT-GROUP OBJECTS { vmwNsxTDataCenterLrportId, vmwNsxTDataCenterServiceIP } STATUS current DESCRIPTION "These objects provide details in NSX Data Center event notifications." ::= { vmwNsxTDataCenterSMIBGroups 11 } vmwNsxTDataCenterNotificationGroup6 NOTIFICATION-GROUP NOTIFICATIONS { vmwNsxTRoutingProxyARPNotConfiguredForServiceIP, vmwNsxTRoutingProxyARPNotConfiguredForServiceIPClear } STATUS current DESCRIPTION "Group of objects describing event notifications emitted by NSX Data Center. " ::= { vmwNsxTDataCenterSMIBGroups 12 } vmwNsxTDataCenterBasicCompliance7 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxTDataCenterNotificationInfoGroup, vmwNsxTDataCenterNotificationInfoGroup2, vmwNsxTDataCenterNotificationInfoGroup3, vmwNsxTDataCenterNotificationInfoGroup4, vmwNsxTDataCenterNotificationInfoGroup6, vmwNsxTDataCenterNotificationInfoGroup7, vmwNsxTDataCenterNotificationGroup, vmwNsxTDataCenterNotificationGroup2, vmwNsxTDataCenterNotificationGroup3, vmwNsxTDataCenterNotificationGroup4, vmwNsxTDataCenterNotificationGroup5, vmwNsxTDataCenterNotificationGroup6, vmwNsxTDataCenterNotificationGroup7 } ::= { vmwNsxTDataCenterCompliances 7 } vmwNsxTDataCenterNotificationInfoGroup7 OBJECT-GROUP OBJECTS { vmwNsxTDataCenterIntentPath } STATUS current DESCRIPTION "These objects provide details in NSX Data Center event notifications." ::= { vmwNsxTDataCenterSMIBGroups 13 } vmwNsxTDataCenterNotificationGroup7 NOTIFICATION-GROUP NOTIFICATIONS { vmwNsxTIPAMIPBlockUsageVeryHigh, vmwNsxTIPAMIPBlockUsageVeryHighClear, vmwNsxTIPAMIPPoolUsageVeryHigh, vmwNsxTIPAMIPPoolUsageVeryHighClear, vmwNsxTLoadBalancerDLBStatusDown, vmwNsxTLoadBalancerDLBStatusDownClear, vmwNsxTLoadBalancerLBEdgeCapacityInUseHigh, vmwNsxTLoadBalancerLBEdgeCapacityInUseHighClear, vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHigh, vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHighClear, vmwNsxTLoadBalancerLBStatusDegraded, vmwNsxTLoadBalancerLBStatusDegradedClear } STATUS current DESCRIPTION "Group of objects describing event notifications emitted by NSX Data Center. " ::= { vmwNsxTDataCenterSMIBGroups 14 } vmwNsxTDataCenterBasicCompliance8 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxTDataCenterNotificationInfoGroup, vmwNsxTDataCenterNotificationInfoGroup2, vmwNsxTDataCenterNotificationInfoGroup3, vmwNsxTDataCenterNotificationInfoGroup4, vmwNsxTDataCenterNotificationInfoGroup7, vmwNsxTDataCenterNotificationInfoGroup8, vmwNsxTDataCenterNotificationGroup, vmwNsxTDataCenterNotificationGroup2, vmwNsxTDataCenterNotificationGroup3, vmwNsxTDataCenterNotificationGroup4, vmwNsxTDataCenterNotificationGroup5, vmwNsxTDataCenterNotificationGroup6, vmwNsxTDataCenterNotificationGroup7, vmwNsxTDataCenterNotificationGroup8 } ::= { vmwNsxTDataCenterCompliances 8 } vmwNsxTDataCenterNotificationInfoGroup8 OBJECT-GROUP OBJECTS { vmwNsxTDataCenterDNSId, vmwNsxTDataCenterDNSUpstreamIP, vmwNsxTDataCenterFirewallHalfopenFlowUsage, vmwNsxTDataCenterFirewallICMPFlowUsage, vmwNsxTDataCenterFirewallIPFlowUsage, vmwNsxTDataCenterFirewallUDPFlowUsage } STATUS current DESCRIPTION "These objects provide details in NSX Data Center event notifications." ::= { vmwNsxTDataCenterSMIBGroups 15 } vmwNsxTDataCenterNotificationGroup8 NOTIFICATION-GROUP NOTIFICATIONS { vmwNsxTDNSForwarderUpstreamServerTimeout, vmwNsxTDNSForwarderUpstreamServerTimeoutClear, vmwNsxTGatewayFirewallICMPFlowCountExceeded, vmwNsxTGatewayFirewallICMPFlowCountExceededClear, vmwNsxTGatewayFirewallICMPFlowCountHigh, vmwNsxTGatewayFirewallICMPFlowCountHighClear, vmwNsxTGatewayFirewallIPFlowCountExceeded, vmwNsxTGatewayFirewallIPFlowCountExceededClear, vmwNsxTGatewayFirewallIPFlowCountHigh, vmwNsxTGatewayFirewallIPFlowCountHighClear, vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceeded, vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceededClear, vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHigh, vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHighClear, vmwNsxTGatewayFirewallUDPFlowCountExceeded, vmwNsxTGatewayFirewallUDPFlowCountExceededClear, vmwNsxTGatewayFirewallUDPFlowCountHigh, vmwNsxTGatewayFirewallUDPFlowCountHighClear } STATUS current DESCRIPTION "Group of objects describing event notifications emitted by NSX Data Center. " ::= { vmwNsxTDataCenterSMIBGroups 16 } vmwNsxTDataCenterBasicCompliance9 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxTDataCenterNotificationInfoGroup, vmwNsxTDataCenterNotificationInfoGroup2, vmwNsxTDataCenterNotificationInfoGroup3, vmwNsxTDataCenterNotificationInfoGroup4, vmwNsxTDataCenterNotificationInfoGroup7, vmwNsxTDataCenterNotificationInfoGroup8, vmwNsxTDataCenterNotificationInfoGroup9, vmwNsxTDataCenterNotificationGroup, vmwNsxTDataCenterNotificationGroup2, vmwNsxTDataCenterNotificationGroup3, vmwNsxTDataCenterNotificationGroup4, vmwNsxTDataCenterNotificationGroup5, vmwNsxTDataCenterNotificationGroup6, vmwNsxTDataCenterNotificationGroup7, vmwNsxTDataCenterNotificationGroup8, vmwNsxTDataCenterNotificationGroup9 } ::= { vmwNsxTDataCenterCompliances 9 } vmwNsxTDataCenterNotificationInfoGroup9 OBJECT-GROUP OBJECTS { vmwNsxTDataCenterAPICollectionPath, vmwNsxTDataCenterCABundleAgeThreshold, vmwNsxTDataCenterEdgeCryptoDrvName, vmwNsxTDataCenterEdgeNodeSettingMismatchReason, vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason, vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason, vmwNsxTDataCenterEdgevSphereLocationMismatchReason, vmwNsxTDataCenterFirewallSNATPortsUsage, vmwNsxTDataCenterFlowIdentifier, vmwNsxTDataCenterFromGMPath, vmwNsxTDataCenterGroupType, vmwNsxTDataCenterManagerNodeIDS, vmwNsxTDataCenterNICThroughput, vmwNsxTDataCenterNICThroughputThreshold, vmwNsxTDataCenterNappClusterId, vmwNsxTDataCenterNappMessagingLAGThreshold, vmwNsxTDataCenterNappNodeId, vmwNsxTDataCenterNappNodeName, vmwNsxTDataCenterNappServiceName, vmwNsxTDataCenterQueueName, vmwNsxTDataCenterQueueSize, vmwNsxTDataCenterQueueSizeThreshold, vmwNsxTDataCenterSNATIPAddress, vmwNsxTDataCenterServiceDownReason, vmwNsxTDataCenterServiceRouterId, vmwNsxTDataCenterSyncIssueReason, vmwNsxTDataCenterToGMPath, vmwNsxTDataCenterTransportNodeId } STATUS current DESCRIPTION "These objects provide details in NSX Data Center event notifications." ::= { vmwNsxTDataCenterSMIBGroups 17 } vmwNsxTDataCenterNotificationGroup9 NOTIFICATION-GROUP NOTIFICATIONS { vmwNsxTCertificatesCABundleUpdateRecommended, vmwNsxTCertificatesCABundleUpdateRecommendedClear, vmwNsxTCertificatesCABundleUpdateSuggested, vmwNsxTCertificatesCABundleUpdateSuggestedClear, vmwNsxTClusteringClusterDegraded, vmwNsxTClusteringClusterDegradedClear, vmwNsxTClusteringClusterUnavailable, vmwNsxTClusteringClusterUnavailableClear, vmwNsxTCommunicationManagementChannelToManagerNodeDown, vmwNsxTCommunicationManagementChannelToManagerNodeDownClear, vmwNsxTCommunicationManagementChannelToManagerNodeDownLong, vmwNsxTCommunicationManagementChannelToManagerNodeDownLongClear, vmwNsxTDistributedFirewallDFWSessionCountHigh, vmwNsxTDistributedFirewallDFWSessionCountHighClear, vmwNsxTDistributedFirewallDFWVmotionFailure, vmwNsxTDistributedFirewallDFWVmotionFailureClear, vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChanged, vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChangedClear, vmwNsxTEdgeEdgeNodeSettingsMismatch, vmwNsxTEdgeEdgeNodeSettingsMismatchClear, vmwNsxTEdgeEdgeVmvSphereSettingsMismatch, vmwNsxTEdgeEdgeVmvSphereSettingsMismatchClear, vmwNsxTEdgeEdgevSphereLocationMismatch, vmwNsxTEdgeEdgevSphereLocationMismatchClear, vmwNsxTEdgeHealthEdgeDatapathNICThroughputHigh, vmwNsxTEdgeHealthEdgeDatapathNICThroughputHighClear, vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHigh, vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHighClear, vmwNsxTEdgeHealthFailureDomainDown, vmwNsxTEdgeHealthFailureDomainDownClear, vmwNsxTFederationGMToGMLatencyWarning, vmwNsxTFederationGMToGMLatencyWarningClear, vmwNsxTFederationGMToGMSynchronizationError, vmwNsxTFederationGMToGMSynchronizationErrorClear, vmwNsxTFederationGMToGMSynchronizationWarning, vmwNsxTFederationGMToGMSynchronizationWarningClear, vmwNsxTFederationGMToLMLatencyWarning, vmwNsxTFederationGMToLMLatencyWarningClear, vmwNsxTFederationGMToLMSynchronizationError, vmwNsxTFederationGMToLMSynchronizationErrorClear, vmwNsxTFederationGMToLMSynchronizationWarning, vmwNsxTFederationGMToLMSynchronizationWarningClear, vmwNsxTFederationLMRestoreWhileConfigImportInProgress, vmwNsxTFederationLMRestoreWhileConfigImportInProgressClear, vmwNsxTFederationQueueOccupancyThresholdExceeded, vmwNsxTFederationQueueOccupancyThresholdExceededClear, vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemory, vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemoryClear, vmwNsxTMTUCheckGlobalRouterMTUTooBig, vmwNsxTMTUCheckGlobalRouterMTUTooBigClear, vmwNsxTMTUCheckMTUMismatchWithinTransportZone, vmwNsxTMTUCheckMTUMismatchWithinTransportZoneClear, vmwNsxTNATSNATPortUsageOnGatewayIsHigh, vmwNsxTNATSNATPortUsageOnGatewayIsHighClear, vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflow, vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflowClear, vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflow, vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflowClear, vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnected, vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnectedClear, vmwNsxTNSXApplicationPlatformCommunicationExpDisconnected, vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectedClear, vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHigh, vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHighClear, vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHi, vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHiClear, vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHigh, vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHighClear, vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHi, vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHiClear, vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHigh, vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHighClear, vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHi, vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHiClear, vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHigh, vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHighClear, vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHigh, vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHighClear, vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHigh, vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHighClear, vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHigh, vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHighClear, vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHigh, vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHighClear, vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHi, vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHiClear, vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHi, vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHiClear, vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHi, vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHiClear, vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHigh, vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHighClear, vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHi, vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHiClear, vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHigh, vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHighClear, vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHigh, vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHighClear, vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHigh, vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHighClear, vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHi, vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHiClear, vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHigh, vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHighClear, vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHi, vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHiClear, vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHigh, vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHighClear, vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHi, vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHiClear, vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHigh, vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHighClear, vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHi, vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHiClear, vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHigh, vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHighClear, vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHi, vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHiClear, vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHigh, vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHighClear, vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHi, vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHiClear, vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHigh, vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHighClear, vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHigh, vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHighClear, vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHi, vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHiClear, vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHigh, vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHighClear, vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHi, vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHiClear, vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHigh, vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHighClear, vmwNsxTNSXApplicationPlatformHealthNappStatusDegraded, vmwNsxTNSXApplicationPlatformHealthNappStatusDegradedClear, vmwNsxTNSXApplicationPlatformHealthNappStatusDown, vmwNsxTNSXApplicationPlatformHealthNappStatusDownClear, vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHigh, vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHighClear, vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHigh, vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHighClear, vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHigh, vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHighClear, vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHigh, vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHighClear, vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHigh, vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHighClear, vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHigh, vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHighClear, vmwNsxTNSXApplicationPlatformHealthNodeStatusDegraded, vmwNsxTNSXApplicationPlatformHealthNodeStatusDegradedClear, vmwNsxTNSXApplicationPlatformHealthNodeStatusDown, vmwNsxTNSXApplicationPlatformHealthNodeStatusDownClear, vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHigh, vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHighClear, vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHigh, vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHighClear, vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHigh, vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHighClear, vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHi, vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHiClear, vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHigh, vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHighClear, vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHi, vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHiClear, vmwNsxTNSXApplicationPlatformHealthServiceStatusDegraded, vmwNsxTNSXApplicationPlatformHealthServiceStatusDegradedClear, vmwNsxTNSXApplicationPlatformHealthServiceStatusDown, vmwNsxTNSXApplicationPlatformHealthServiceStatusDownClear, vmwNsxTTransportNodeHealthTransportNodeUplinkDown, vmwNsxTTransportNodeHealthTransportNodeUplinkDownClear, vmwNsxTVPNIPsecServiceDown, vmwNsxTVPNIPsecServiceDownClear } STATUS current DESCRIPTION "Group of objects describing event notifications emitted by NSX Data Center. " ::= { vmwNsxTDataCenterSMIBGroups 18 } vmwNsxTDataCenterBasicCompliance10 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxTDataCenterNotificationInfoGroup, vmwNsxTDataCenterNotificationInfoGroup2, vmwNsxTDataCenterNotificationInfoGroup3, vmwNsxTDataCenterNotificationInfoGroup4, vmwNsxTDataCenterNotificationInfoGroup6, vmwNsxTDataCenterNotificationInfoGroup7, vmwNsxTDataCenterNotificationInfoGroup8, vmwNsxTDataCenterNotificationInfoGroup9, vmwNsxTDataCenterNotificationInfoGroup10, vmwNsxTDataCenterNotificationGroup, vmwNsxTDataCenterNotificationGroup2, vmwNsxTDataCenterNotificationGroup3, vmwNsxTDataCenterNotificationGroup4, vmwNsxTDataCenterNotificationGroup5, vmwNsxTDataCenterNotificationGroup6, vmwNsxTDataCenterNotificationGroup7, vmwNsxTDataCenterNotificationGroup8, vmwNsxTDataCenterNotificationGroup9, vmwNsxTDataCenterNotificationGroup10 } ::= { vmwNsxTDataCenterCompliances 10 } vmwNsxTDataCenterNotificationInfoGroup10 OBJECT-GROUP OBJECTS { vmwNsxTDataCenterNewVMMorefId, vmwNsxTDataCenterPolicyEdgeVMName, vmwNsxTDataCenterVMMorefId } STATUS current DESCRIPTION "These objects provide details in NSX Data Center event notifications." ::= { vmwNsxTDataCenterSMIBGroups 19 } vmwNsxTDataCenterNotificationGroup10 NOTIFICATION-GROUP NOTIFICATIONS { vmwNsxTEdgeEdgeVMNotPresentInBothNSXInventoryAndvCenter, vmwNsxTEdgeEdgeVMNotPresentInBothNSXInventoryAndvCenterClear, vmwNsxTEdgeEdgeVMPresentInNSXInventoryNotPresentInvCenter, vmwNsxTEdgeEdgeVMPresentInNSXInventoryNotPresentInvCenterClear, vmwNsxTEdgeFailedToDeleteTheOldVMInvCenterDuringRedeploy, vmwNsxTEdgeFailedToDeleteTheOldVMInvCenterDuringRedeployClear } STATUS current DESCRIPTION "Group of objects describing event notifications emitted by NSX Data Center. " ::= { vmwNsxTDataCenterSMIBGroups 20 } vmwNsxTDataCenterBasicCompliance11 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxTDataCenterNotificationInfoGroup, vmwNsxTDataCenterNotificationInfoGroup2, vmwNsxTDataCenterNotificationInfoGroup3, vmwNsxTDataCenterNotificationInfoGroup4, vmwNsxTDataCenterNotificationInfoGroup6, vmwNsxTDataCenterNotificationInfoGroup7, vmwNsxTDataCenterNotificationInfoGroup8, vmwNsxTDataCenterNotificationInfoGroup9, vmwNsxTDataCenterNotificationInfoGroup10, vmwNsxTDataCenterNotificationInfoGroup11, vmwNsxTDataCenterNotificationGroup, vmwNsxTDataCenterNotificationGroup2, vmwNsxTDataCenterNotificationGroup3, vmwNsxTDataCenterNotificationGroup4, vmwNsxTDataCenterNotificationGroup5, vmwNsxTDataCenterNotificationGroup6, vmwNsxTDataCenterNotificationGroup7, vmwNsxTDataCenterNotificationGroup8, vmwNsxTDataCenterNotificationGroup9, vmwNsxTDataCenterNotificationGroup10, vmwNsxTDataCenterNotificationGroup11 } ::= { vmwNsxTDataCenterCompliances 11 } vmwNsxTDataCenterNotificationInfoGroup11 OBJECT-GROUP OBJECTS { vmwNsxTDataCenterCoreId, vmwNsxTDataCenterFlowCacheThreshold } STATUS current DESCRIPTION "These objects provide details in NSX-T Data Center event notifications." ::= { vmwNsxTDataCenterSMIBGroups 21 } vmwNsxTDataCenterNotificationGroup11 NOTIFICATION-GROUP NOTIFICATIONS { vmwNsxTEdgeHealthMegaFlowCacheHitRateLow, vmwNsxTEdgeHealthMegaFlowCacheHitRateLowClear, vmwNsxTEdgeHealthMicroFlowCacheHitRateLow, vmwNsxTEdgeHealthMicroFlowCacheHitRateLowClear } STATUS current DESCRIPTION "Group of objects describing event notifications emitted by NSX-T Data Center. " ::= { vmwNsxTDataCenterSMIBGroups 22 } vmwNsxTDataCenterBasicCompliance12 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxTDataCenterNotificationInfoGroup, vmwNsxTDataCenterNotificationInfoGroup2, vmwNsxTDataCenterNotificationInfoGroup3, vmwNsxTDataCenterNotificationInfoGroup4, vmwNsxTDataCenterNotificationInfoGroup6, vmwNsxTDataCenterNotificationInfoGroup7, vmwNsxTDataCenterNotificationInfoGroup8, vmwNsxTDataCenterNotificationInfoGroup9, vmwNsxTDataCenterNotificationInfoGroup10, vmwNsxTDataCenterNotificationInfoGroup11, vmwNsxTDataCenterNotificationInfoGroup12, vmwNsxTDataCenterNotificationGroup, vmwNsxTDataCenterNotificationGroup2, vmwNsxTDataCenterNotificationGroup3, vmwNsxTDataCenterNotificationGroup4, vmwNsxTDataCenterNotificationGroup5, vmwNsxTDataCenterNotificationGroup6, vmwNsxTDataCenterNotificationGroup7, vmwNsxTDataCenterNotificationGroup8, vmwNsxTDataCenterNotificationGroup9, vmwNsxTDataCenterNotificationGroup10, vmwNsxTDataCenterNotificationGroup11, vmwNsxTDataCenterNotificationGroup12 } ::= { vmwNsxTDataCenterCompliances 12 } vmwNsxTDataCenterNotificationInfoGroup12 OBJECT-GROUP OBJECTS { vmwNsxTDataCenterCoreDumpCount, vmwNsxTDataCenterDPUId, vmwNsxTDataCenterEdgeClusterId, vmwNsxTDataCenterEdgeNode, vmwNsxTDataCenterMemberIndexId, vmwNsxTDataCenterMpsServiceName, vmwNsxTDataCenterNSXESXTNName, vmwNsxTDataCenterNSXEdgeTNName, vmwNsxTDataCenterNodeDisplayOrHostName, vmwNsxTDataCenterPrefixesCountMax, vmwNsxTDataCenterPrefixesCountThreshold, vmwNsxTDataCenterRouteLimitMaximum, vmwNsxTDataCenterRouteLimitThreshold, vmwNsxTDataCenterSubsequentAddressFamily, vmwNsxTDataCentervCenterClusterId } STATUS current DESCRIPTION "These objects provide details in NSX-T Data Center event notifications." ::= { vmwNsxTDataCenterSMIBGroups 23 } vmwNsxTDataCenterNotificationGroup12 NOTIFICATION-GROUP NOTIFICATIONS { vmwNsxTCniHealthHyperbusManagerConnectionDownOnDPU, vmwNsxTCniHealthHyperbusManagerConnectionDownOnDPUClear, vmwNsxTCommunicationNetworkLatencyHigh, vmwNsxTCommunicationNetworkLatencyHighClear, vmwNsxTDistributedFirewallDFWCPUUsageVeryHighOnDPU, vmwNsxTDistributedFirewallDFWCPUUsageVeryHighOnDPUClear, vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighOnDPU, vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighOnDPUClear, vmwNsxTDistributedFirewallDFWRulesLimitPerHostApproaching, vmwNsxTDistributedFirewallDFWRulesLimitPerHostApproachingClear, vmwNsxTDistributedFirewallDFWRulesLimitPerHostExceeded, vmwNsxTDistributedFirewallDFWRulesLimitPerHostExceededClear, vmwNsxTDistributedFirewallDFWRulesLimitPervNICApproaching, vmwNsxTDistributedFirewallDFWRulesLimitPervNICApproachingClear, vmwNsxTDistributedFirewallDFWRulesLimitPervNICExceeded, vmwNsxTDistributedFirewallDFWRulesLimitPervNICExceededClear, vmwNsxTDistributedIDSIPSIDPSBypassedCPUOversubscribed, vmwNsxTDistributedIDSIPSIDPSBypassedCPUOversubscribedClear, vmwNsxTDistributedIDSIPSIDPSBypassedNetworkOversubscribed, vmwNsxTDistributedIDSIPSIDPSBypassedNetworkOversubscribedClear, vmwNsxTDistributedIDSIPSIDPSEngineCPUOversubscriptionHigh, vmwNsxTDistributedIDSIPSIDPSEngineCPUOversubscriptionHighClear, vmwNsxTDistributedIDSIPSIDPSCPUOversubscriptionVeryHigh, vmwNsxTDistributedIDSIPSIDPSCPUOversubscriptionVeryHighClear, vmwNsxTDistributedIDSIPSIDPSDroppedCPUOversubscribed, vmwNsxTDistributedIDSIPSIDPSDroppedCPUOversubscribedClear, vmwNsxTDistributedIDSIPSIDPSDroppedNetworkOversubscribed, vmwNsxTDistributedIDSIPSIDPSDroppedNetworkOversubscribedClear, vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionHigh, vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionHighClear, vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionVeryHigh, vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionVeryHighClear, vmwNsxTDistributedIDSIPSNSXIDPSEngineDownOnDPU, vmwNsxTDistributedIDSIPSNSXIDPSEngineDownOnDPUClear, vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighOnDPU, vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighOnDPUClear, vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageMedHighOnDPU, vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageMedHighOnDPUClear, vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageVeryHighDPU, vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageVeryHighDPUClear, vmwNsxTEdgeClusterEdgeClusterMemberRelocateFailure, vmwNsxTEdgeClusterEdgeClusterMemberRelocateFailureClear, vmwNsxTInfrastructureServiceApplicationCrashed, vmwNsxTInfrastructureServiceApplicationCrashedClear, vmwNsxTInfrastructureServiceServiceStatusUnknownOnDPU, vmwNsxTInfrastructureServiceServiceStatusUnknownOnDPUClear, vmwNsxTMalwarePreventionHealthAnalystAPIServiceUnreachable, vmwNsxTMalwarePreventionHealthAnalystAPIServiceUnreachableClear, vmwNsxTMalwarePreventionHealthDatabaseUnreachable, vmwNsxTMalwarePreventionHealthDatabaseUnreachableClear, vmwNsxTMalwarePreventionHealthFileExtractSvcUnreachable, vmwNsxTMalwarePreventionHealthFileExtractSvcUnreachableClear, vmwNsxTMalwarePreventionHealthNTICSRepSvcUnreachable, vmwNsxTMalwarePreventionHealthNTICSRepSvcUnreachableClear, vmwNsxTMalwarePreventionHealthServiceStatusDown, vmwNsxTMalwarePreventionHealthServiceStatusDownClear, vmwNsxTNodeAgentsHealthNodeAgentsDownOnDPU, vmwNsxTNodeAgentsHealthNodeAgentsDownOnDPUClear, vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectDPU, vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectDPUClear, vmwNsxTPhysicalServerPhysicalServerInstallFailed, vmwNsxTPhysicalServerPhysicalServerInstallFailedClear, vmwNsxTPhysicalServerPhysicalServerUninstallFailed, vmwNsxTPhysicalServerPhysicalServerUninstallFailedClear, vmwNsxTPhysicalServerPhysicalServerUpgradeFailed, vmwNsxTPhysicalServerPhysicalServerUpgradeFailedClear, vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborApproaching, vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborApproachingClear, vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborExceeded, vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborExceededClear, vmwNsxTRoutingMaximumIPv4RouteLimitApproaching, vmwNsxTRoutingMaximumIPv4RouteLimitApproachingClear, vmwNsxTRoutingMaximumIPv4RouteLimitExceeded, vmwNsxTRoutingMaximumIPv4RouteLimitExceededClear, vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborApproaching, vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborApproachingClear, vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborExceeded, vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborExceededClear, vmwNsxTRoutingMaximumIPv6RouteLimitApproaching, vmwNsxTRoutingMaximumIPv6RouteLimitApproachingClear, vmwNsxTRoutingMaximumIPv6RouteLimitExceeded, vmwNsxTRoutingMaximumIPv6RouteLimitExceededClear, vmwNsxTServiceInsertionNewHostAdded, vmwNsxTServiceInsertionNewHostAddedClear, vmwNsxTServiceInsertionServiceChainPathDown, vmwNsxTServiceInsertionServiceChainPathDownClear, vmwNsxTServiceInsertionServiceDeploymentFailed, vmwNsxTServiceInsertionServiceDeploymentFailedClear, vmwNsxTServiceInsertionServiceDeploymentSucceeded, vmwNsxTServiceInsertionServiceDeploymentSucceededClear, vmwNsxTServiceInsertionServiceInsertionInfraStatusDown, vmwNsxTServiceInsertionServiceInsertionInfraStatusDownClear, vmwNsxTServiceInsertionServiceUndeploymentFailed, vmwNsxTServiceInsertionServiceUndeploymentFailedClear, vmwNsxTServiceInsertionServiceUndeploymentSucceeded, vmwNsxTServiceInsertionServiceUndeploymentSucceededClear, vmwNsxTServiceInsertionSVMHealthStatusDown, vmwNsxTServiceInsertionSVMHealthStatusDownClear, vmwNsxTServiceInsertionSVMHealthStatusUp, vmwNsxTServiceInsertionSVMHealthStatusUpClear, vmwNsxTServiceInsertionSVMLivenessStateDown, vmwNsxTServiceInsertionSVMLivenessStateDownClear, vmwNsxTTransportNodeHealthLAGMemberDownOnDPU, vmwNsxTTransportNodeHealthLAGMemberDownOnDPUClear, vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPU, vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPUClear } STATUS current DESCRIPTION "Group of objects describing event notifications emitted by NSX-T Data Center. " ::= { vmwNsxTDataCenterSMIBGroups 24 } vmwNsxTDataCenterBasicCompliance13 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxTDataCenterNotificationInfoGroup, vmwNsxTDataCenterNotificationInfoGroup2, vmwNsxTDataCenterNotificationInfoGroup3, vmwNsxTDataCenterNotificationInfoGroup4, vmwNsxTDataCenterNotificationInfoGroup6, vmwNsxTDataCenterNotificationInfoGroup7, vmwNsxTDataCenterNotificationInfoGroup8, vmwNsxTDataCenterNotificationInfoGroup9, vmwNsxTDataCenterNotificationInfoGroup10, vmwNsxTDataCenterNotificationInfoGroup11, vmwNsxTDataCenterNotificationInfoGroup12, vmwNsxTDataCenterNotificationInfoGroup13, vmwNsxTDataCenterNotificationGroup, vmwNsxTDataCenterNotificationGroup2, vmwNsxTDataCenterNotificationGroup3, vmwNsxTDataCenterNotificationGroup4, vmwNsxTDataCenterNotificationGroup5, vmwNsxTDataCenterNotificationGroup6, vmwNsxTDataCenterNotificationGroup7, vmwNsxTDataCenterNotificationGroup8, vmwNsxTDataCenterNotificationGroup9, vmwNsxTDataCenterNotificationGroup10, vmwNsxTDataCenterNotificationGroup11, vmwNsxTDataCenterNotificationGroup12, vmwNsxTDataCenterNotificationGroup13 } ::= { vmwNsxTDataCenterCompliances 13 } vmwNsxTDataCenterNotificationInfoGroup13 OBJECT-GROUP OBJECTS { vmwNsxTDataCenterCollectorIP, vmwNsxTDataCenterDvsAlias, vmwNsxTDataCenterEdgeClusterHighestHwVersion, vmwNsxTDataCenterEdgeClusterName, vmwNsxTDataCenterEdgeTNHwVersion, vmwNsxTDataCenterHaState, vmwNsxTDataCenterHaState2, vmwNsxTDataCenterStackAlias, vmwNsxTDataCenterTransportNodeId2, vmwNsxTDataCenterVerticalName } STATUS current DESCRIPTION "These objects provide details in NSX-T Data Center event notifications." ::= { vmwNsxTDataCenterSMIBGroups 25 } vmwNsxTDataCenterNotificationGroup13 NOTIFICATION-GROUP NOTIFICATIONS { vmwNsxTCommunicationLimitedReachabilityOnDPU, vmwNsxTCommunicationLimitedReachabilityOnDPUClear, vmwNsxTCommunicationUnreachableCollectorOnDPU, vmwNsxTCommunicationUnreachableCollectorOnDPUClear, vmwNsxTEdgeEdgeHardwareVersionMismatch, vmwNsxTEdgeEdgeHardwareVersionMismatchClear, vmwNsxTHighAvailabilityTier0ServiceGroupFailover, vmwNsxTHighAvailabilityTier0ServiceGroupFailoverClear, vmwNsxTHighAvailabilityTier0ServiceGroupReducedRedundancy, vmwNsxTHighAvailabilityTier0ServiceGroupReducedRedundancyClear, vmwNsxTHighAvailabilityTier1ServiceGroupFailover, vmwNsxTHighAvailabilityTier1ServiceGroupFailoverClear, vmwNsxTHighAvailabilityTier1ServiceGroupReducedRedundancy, vmwNsxTHighAvailabilityTier1ServiceGroupReducedRedundancyClear, vmwNsxTMalwarePreventionHealthAnalystAPIServiceUnreachable, vmwNsxTMalwarePreventionHealthAnalystAPIServiceUnreachableClear, vmwNsxTMalwarePreventionHealthDatabaseUnreachable, vmwNsxTMalwarePreventionHealthDatabaseUnreachableClear, vmwNsxTMalwarePreventionHealthFileExtractSvcUnreachable, vmwNsxTMalwarePreventionHealthFileExtractSvcUnreachableClear, vmwNsxTMalwarePreventionHealthServiceStatusDown, vmwNsxTMalwarePreventionHealthServiceStatusDownClear } STATUS current DESCRIPTION "Group of objects describing event notifications emitted by NSX-T Data Center. " ::= { vmwNsxTDataCenterSMIBGroups 26 } vmwNsxTDataCenterBasicCompliance14 MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxTDataCenterNotificationInfoGroup, vmwNsxTDataCenterNotificationInfoGroup2, vmwNsxTDataCenterNotificationInfoGroup3, vmwNsxTDataCenterNotificationInfoGroup4, vmwNsxTDataCenterNotificationInfoGroup6, vmwNsxTDataCenterNotificationInfoGroup7, vmwNsxTDataCenterNotificationInfoGroup8, vmwNsxTDataCenterNotificationInfoGroup9, vmwNsxTDataCenterNotificationInfoGroup10, vmwNsxTDataCenterNotificationInfoGroup11, vmwNsxTDataCenterNotificationInfoGroup12, vmwNsxTDataCenterNotificationInfoGroup13, vmwNsxTDataCenterNotificationInfoGroup14, vmwNsxTDataCenterNotificationGroup, vmwNsxTDataCenterNotificationGroup2, vmwNsxTDataCenterNotificationGroup3, vmwNsxTDataCenterNotificationGroup4, vmwNsxTDataCenterNotificationGroup5, vmwNsxTDataCenterNotificationGroup6, vmwNsxTDataCenterNotificationGroup7, vmwNsxTDataCenterNotificationGroup8, vmwNsxTDataCenterNotificationGroup9, vmwNsxTDataCenterNotificationGroup10, vmwNsxTDataCenterNotificationGroup11, vmwNsxTDataCenterNotificationGroup12, vmwNsxTDataCenterNotificationGroup13, vmwNsxTDataCenterNotificationGroup14 } ::= { vmwNsxTDataCenterCompliances 14 } vmwNsxTDataCenterNotificationInfoGroup14 OBJECT-GROUP OBJECTS { vmwNsxTDataCenterConstraintLimit, vmwNsxTDataCenterConstraintType, vmwNsxTDataCenterConstraintTypePath, vmwNsxTDataCenterCurrentCount, vmwNsxTDataCenterDvsName, vmwNsxTDataCenterGroupId, vmwNsxTDataCenterGroupMaxNumberLimit, vmwNsxTDataCenterGroupSize, vmwNsxTDataCenterIPCount, vmwNsxTDataCenterIPv4Address, vmwNsxTDataCenterIPv6Address, vmwNsxTDataCenterLrpCount, vmwNsxTDataCenterLspCount, vmwNsxTDataCenterMacCount, vmwNsxTDataCenterMetricsTargetAddress, vmwNsxTDataCenterMetricsTargetAlias, vmwNsxTDataCenterMetricsTargetPort, vmwNsxTDataCenterNSXaaSServiceName, vmwNsxTDataCenterProtocolName, vmwNsxTDataCenterSidCount, vmwNsxTDataCenterTNCount, vmwNsxTDataCenterVMCount, vmwNsxTDataCenterVifCount, vmwNsxTDataCenterVtepFaultReason, vmwNsxTDataCenterVtepName } STATUS current DESCRIPTION "These objects provide details in NSX-T Data Center event notifications." ::= { vmwNsxTDataCenterSMIBGroups 27 } vmwNsxTDataCenterNotificationGroup14 NOTIFICATION-GROUP NOTIFICATIONS { vmwNsxTCertificatesTransportNodeCertificateExpirApproaching, vmwNsxTCertificatesTransportNodeCertificateExpirApproachingClear, vmwNsxTCertificatesTransportNodeCertificateExpired, vmwNsxTCertificatesTransportNodeCertificateExpiredClear, vmwNsxTCertificatesTransportNodeCertificateIsAboutToExpire, vmwNsxTCertificatesTransportNodeCertificateIsAboutToExpireClear, vmwNsxTDistributedFirewallDFWFloodLimitCritical, vmwNsxTDistributedFirewallDFWFloodLimitCriticalClear, vmwNsxTDistributedFirewallDFWFloodLimitWarning, vmwNsxTDistributedFirewallDFWFloodLimitWarningClear, vmwNsxTGroupsGroupSizeLimitExceeded, vmwNsxTGroupsGroupSizeLimitExceededClear, vmwNsxTInfrastructureServiceMetricsDeliveryFailure, vmwNsxTInfrastructureServiceMetricsDeliveryFailureClear, vmwNsxTMalwarePreventionHealthNTICSRepSvcUnreachable, vmwNsxTMalwarePreventionHealthNTICSRepSvcUnreachableClear, vmwNsxTManagerHealthMissingDNSEntryForManagerFQDN, vmwNsxTManagerHealthMissingDNSEntryForManagerFQDNClear, vmwNsxTManagerHealthMissingDNSEntryForVipFQDN, vmwNsxTManagerHealthMissingDNSEntryForVipFQDNClear, vmwNsxTPolicyConstraintCreationCountLimitReached, vmwNsxTPolicyConstraintCreationCountLimitReachedClear, vmwNsxTSecurityCompliancePollEAL4NonCompliance, vmwNsxTSecurityCompliancePollEAL4NonComplianceClear, vmwNsxTSecurityCompliancePollNDcPPNonCompliance, vmwNsxTSecurityCompliancePollNDcPPNonComplianceClear, vmwNsxTSecurityComplianceTriggerEAL4NonCompliance, vmwNsxTSecurityComplianceTriggerEAL4NonComplianceClear, vmwNsxTSecurityComplianceTriggerNDcPPNonCompliance, vmwNsxTSecurityComplianceTriggerNDcPPNonComplianceClear, vmwNsxTTEPHealthFaultyTEP, vmwNsxTTEPHealthFaultyTEPClear, vmwNsxTTEPHealthFaultyTEPOnDPU, vmwNsxTTEPHealthFaultyTEPOnDPUClear, vmwNsxTTEPHealthTEPAutorecoverFailure, vmwNsxTTEPHealthTEPAutorecoverFailureClear, vmwNsxTTEPHealthTEPAutorecoverFailureOnDPU, vmwNsxTTEPHealthTEPAutorecoverFailureOnDPUClear, vmwNsxTTEPHealthTEPAutorecoverSuccess, vmwNsxTTEPHealthTEPAutorecoverSuccessClear, vmwNsxTTEPHealthTEPAutorecoverSuccessOnDPU, vmwNsxTTEPHealthTEPAutorecoverSuccessOnDPUClear, vmwNsxTTEPHealthTEPHaActivated, vmwNsxTTEPHealthTEPHaActivatedClear, vmwNsxTTEPHealthTEPHaActivatedOnDPU, vmwNsxTTEPHealthTEPHaActivatedOnDPUClear, vmwNsxTVMCAppTransitConnectFailure, vmwNsxTVMCAppTransitConnectFailureClear } STATUS current DESCRIPTION "Group of objects describing event notifications emitted by NSX-T Data Center. " ::= { vmwNsxTDataCenterSMIBGroups 28 } END