TSL-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, Opaque FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; -- MODULE-IDENTITY -- FROM SNMPv2-SMI; -- TSL_MIB; SNMP v1 agent definitions. -- the following only allowed in SMIv2 (also 0 enumeration of integers) -- As of 08/08/03, includes enterprise specific trap definitions (RFC1215) -- As of 08/08/08, added current sense data -- As of 08/08/09, added voltage measure and trap -- As of 04/04/10, added currentAlarm to alarmType, new contact details -- tslMIB MODULE-IDENTITY -- LAST-UPDATED "1004040000Z" -- ORGANIZATION "Television Systems Ltd" -- CONTACT-INFO " -- Tony Orme -- Television Systems Ltd -- Vanwall Road -- Maidenhead -- Berkshire -- SL6 4UB -- -- Tel + 44 1628 676200 -- Email: tony.orme@tsl.co.uk" -- DESCRIPTION "MIB module for all TSL products" -- ::= { enterprises 6853 } DisplayString ::= OCTET STRING -- SMIv1 definition of module tslMIB OBJECT IDENTIFIER ::= { enterprises 6853 } ------------------ Winsoft specific MIB -- DELETED for mdu12 hardware --------------------------------------------------- -------------- generic alarm MIB (all TSL equipment capable of SNMP alarms) alarm OBJECT IDENTIFIER ::= { tslMIB 2 } alarmIdent OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Equipment alarms description and version" ::= { alarm 1 } ------- alarm table alarmTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of alarm entries" ::= { alarm 2 } alarmEntry OBJECT-TYPE SYNTAX AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An alarm entry in the table" INDEX { alarmTableIndex } ::= { alarmTable 1} AlarmEntry ::= SEQUENCE { alarmTableIndex INTEGER, alarmType INTEGER, alarmIndex INTEGER, alarmText DisplayString, alarmState INTEGER, alarmPolarity INTEGER, alarmData Opaque } alarmTableIndex OBJECT-TYPE SYNTAX INTEGER (1..28) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the table" ::= { alarmEntry 1 } alarmType OBJECT-TYPE SYNTAX INTEGER { internal(1), -- general internal to equipment alarm gpi(2), -- from external GPI, alarmPolarity determines alarmState outputFail(3), -- eg MDU12 output fuse, etc psuFail(4), -- alarmData is text describing failure (eg rail values etc) currentAlarm(5) -- eg MDU12 output current } ACCESS read-only STATUS mandatory DESCRIPTION "Alarm type" ::= { alarmEntry 2 } alarmIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Alarm type number" ::= { alarmEntry 3 } alarmText OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Alarm description" ::= { alarmEntry 4 } alarmState OBJECT-TYPE SYNTAX INTEGER { inactive(1), active(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Alarm state" ::= { alarmEntry 5 } alarmPolarity OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), normallyOpen(2), normallyClosed(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Alarm active polarity (notApplicable for non-gpi alarms)" ::= { alarmEntry 6 } alarmData OBJECT-TYPE SYNTAX Opaque ACCESS read-only STATUS optional DESCRIPTION "Additional alarm data of variable length, according to alarm type." ::= { alarmEntry 7 } ------- end of table alarmTotal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of alarms in the table" ::= { alarm 3 } alarmLocation OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The physical location of the equipment generating the alarm" ::= { alarm 4 } alarmEqptTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Equipment temperature (in degrees Centigrade)" ::= { alarm 5 } alarmEqptTempHi OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Equipment temperature alarm point (degrees Centigrade)" ::= { alarm 6 } alarmTrap TRAP-TYPE ENTERPRISE tslMIB VARIABLES { alarmTableIndex, alarmType, alarmIndex, alarmText, alarmState, alarmPolarity, alarmData } DESCRIPTION "An entry in the alarm table has changed state" ::= 4 alarmEqptTempHiTrap TRAP-TYPE ENTERPRISE tslMIB VARIABLES { alarmEqptTemp } DESCRIPTION "The equipment temperature has exceeded the maximum allowed" ::= 5 alarmEqptTempOkTrap TRAP-TYPE ENTERPRISE tslMIB VARIABLES { alarmEqptTemp } DESCRIPTION "The equipment temperature is now within limits" ::= 6 --------------------------------------------------- -------------- MDU12 specific MIB mdu12 OBJECT IDENTIFIER ::= { tslMIB 3 } mdu12Ident OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Equipment description and version" ::= { mdu12 1 } mduPowerOn OBJECT-TYPE SYNTAX INTEGER { simultaneous(1), sequential(2), delayed(3) } ACCESS read-write STATUS mandatory DESCRIPTION "MDU power-on output sequence" ::= { mdu12 2 } mduSeqDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sequential mode delay between outputs" ::= { mdu12 3 } mduOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF MduOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of output controls" ::= { mdu12 4 } mduOutputEntry OBJECT-TYPE SYNTAX MduOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry in the output table" INDEX {mduOutputIndex} ::= { mduOutputTable 1} MduOutputEntry ::= SEQUENCE { mduOutputIndex INTEGER, mduOutputState INTEGER, mduOutputDelay INTEGER, mduOutputlowerCurrent INTEGER, mduOutputupperCurrent INTEGER, mduOutputCurrent INTEGER, mduOutputpowerFactor INTEGER, mduOutputVA INTEGER, mduOutputWatts INTEGER, mduOutputCal INTEGER } mduOutputIndex OBJECT-TYPE SYNTAX INTEGER(1..12) ACCESS read-only STATUS mandatory DESCRIPTION "Output number" ::= { mduOutputEntry 1 } mduOutputState OBJECT-TYPE SYNTAX INTEGER { off(1), on(2), locked-Off(3), -- locked by admin web page, cannot change via SNMP locked-On(4) -- locked by admin web page, cannot change via SNMP } ACCESS read-write STATUS mandatory DESCRIPTION "MDU Output status" ::= { mduOutputEntry 2 } mduOutputDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Output on delay from power on (Delay mode only)" ::= { mduOutputEntry 3 } mduOutputlowerCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Lower current limit for output" ::= { mduOutputEntry 4 } mduOutputupperCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Upper current limit for output" ::= { mduOutputEntry 5 } mduOutputCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Output current" ::= { mduOutputEntry 6 } mduOutputpowerFactor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Output power factor" ::= { mduOutputEntry 7 } mduOutputVA OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Output apparent power" ::= { mduOutputEntry 8 } mduOutputWatts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Output real power" ::= { mduOutputEntry 9 } mduOutputCal OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Output current measure calibration data" ::= { mduOutputEntry 10 } -- End of table mduPowerStatus OBJECT-TYPE SYNTAX INTEGER { totalLoss(1), input1OK(2), input2OK(3), allOk(4) -- note: a single input MDU would report allOk if power is present } ACCESS read-only STATUS mandatory DESCRIPTION "Status of MDU power inlets" ::= { mdu12 5 } mduVoltageCal OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Voltage measure calibration data" ::= { mdu12 6 } mduVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Voltage measurement" ::= { mdu12 7 } mduVoltageFloor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Voltage lower limit" ::= { mdu12 8 } mduVoltageLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Voltage upper limit" ::= { mdu12 9 } mduTotalCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Total current measurement" ::= { mdu12 10 } mduCurrentLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Current total limit" ::= { mdu12 11 } mduAuxRly1 OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Auxiliary Relay 1 state" ::= { mdu12 12 } mduAuxRly2 OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Auxiliary Relay 2 state" ::= { mdu12 13 } mduPowerStatusTrap TRAP-TYPE ENTERPRISE tslMIB VARIABLES { mduPowerStatus } DESCRIPTION "The power input to the MDU has changed state" ::= 7 mduVoltageStatusTrap TRAP-TYPE ENTERPRISE tslMIB VARIABLES { mduVoltage } DESCRIPTION "The voltage to the MDU has traversed a limit" ::= 8 mduTotalCurrentStatusTrap TRAP-TYPE ENTERPRISE tslMIB VARIABLES { mduTotalCurrent } DESCRIPTION "The total current through the MDU has traversed a limit" ::= 9 ------------ END