TPLINK-SNMPRMON-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, TimeTicks, Counter32 FROM SNMPv2-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC tplinkSnmpMIBObjects FROM TPLINK-SNMP-MIB; tpSnmpRmonControl OBJECT IDENTIFIER ::= { tplinkSnmpMIBObjects 2 } tpSnmpRmonStatisticsCtrl OBJECT IDENTIFIER ::= { tpSnmpRmonControl 1 } tpSnmpRmonHistoryCtrl OBJECT IDENTIFIER ::= { tpSnmpRmonControl 2 } tpSnmpRmonEventCtrl OBJECT IDENTIFIER ::= { tpSnmpRmonControl 3 } tpSnmpRmonAlarmCtrl OBJECT IDENTIFIER ::= { tpSnmpRmonControl 4 } EntryStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The status of a table entry." SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } --****************** --Statistics --****************** tpSnmpRmonStatsCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF TPSNMPRMONSTATSCTRLENTRY MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of SNMP RMON STATISTICS control entries." ::= {tpSnmpRmonStatisticsCtrl 1} tpSnmpRmonStatsCtrlEntry OBJECT-TYPE SYNTAX TPSNMPRMONSTATSCTRLENTRY MAX-ACCESS not-accessible STATUS current DESCRIPTION " RMON (Remote Monitoring), basing on SNMP (Simple Network Management Protocol) architecture, functions to monitor the network. Statistics Group, as one of the commonly used RMON Groups, is used to collect the statistics of interfaces. " INDEX { tpSnmpRmonStatsCtrlIndex } ::= { tpSnmpRmonStatsCtrlTable 1 } TPSNMPRMONSTATSCTRLENTRY ::= SEQUENCE { tpSnmpRmonStatsCtrlIndex INTEGER, tpSnmpRmonStatsCtrlDataSource OCTET STRING, tpSnmpRmonStatsCtrlOwner OCTET STRING, tpSnmpRmonStatsCtrlRowStatus EntryStatus } tpSnmpRmonStatsCtrlIndex OBJECT-TYPE SYNTAX INTEGER(1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of this entry." ::= { tpSnmpRmonStatsCtrlEntry 1 } tpSnmpRmonStatsCtrlDataSource OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "This object identifies the source of the data that this statistics entry is configured to analyze. This source can be any ethernet interface on this device. The source should be given as 1/0/1." ::= { tpSnmpRmonStatsCtrlEntry 2 } tpSnmpRmonStatsCtrlOwner OBJECT-TYPE SYNTAX OCTET STRING(SIZE(1..16)) MAX-ACCESS read-create STATUS current DESCRIPTION "The owner of this entry." DEFVAL { "MibBrowser" } ::= { tpSnmpRmonStatsCtrlEntry 3 } tpSnmpRmonStatsCtrlRowStatus OBJECT-TYPE SYNTAX EntryStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status column has four defined values: - 'valid(1)', which indicates that the conceptual row is available for using by the managed device; - 'createRequest(2)', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to valid(1), making it available for using by the managed device; - 'underCreation(3)', which indicates that the conceptual row is existing in the managed device but not working. - 'invalid(4)', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row." DEFVAL { 2 } ::= { tpSnmpRmonStatsCtrlEntry 4 } --****************** --History --****************** tpSnmpRmonHistoryCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF TPSNMPRMONHISTORYCTRLENTRY MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of SNMP RMON hisotry control entries." ::= {tpSnmpRmonHistoryCtrl 1} tpSnmpRmonHistoryCtrlEntry OBJECT-TYPE SYNTAX TPSNMPRMONHISTORYCTRLENTRY MAX-ACCESS not-accessible STATUS current DESCRIPTION " History Group is one of the commonly used RMON (Remote Monitoring) Groups. After a history group is configured, the switch collects network statistics information periodically, based on which the management station can monitor network effectively." INDEX { tpSnmpRmonHistoryCtrlIndex } ::= { tpSnmpRmonHistoryCtrlTable 1 } TPSNMPRMONHISTORYCTRLENTRY ::= SEQUENCE { tpSnmpRmonHistoryCtrlIndex INTEGER, tpSnmpRmonHistoryCtrlSourcePort OCTET STRING, tpSnmpRmonHistoryCtrlInterval INTEGER, tpSnmpRmonHistoryCtrlBucketsRequested INTEGER, tpSnmpRmonHistoryCtrlOwner OCTET STRING, tpSnmpRmonHistoryCtrlStatus INTEGER } tpSnmpRmonHistoryCtrlIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The index of this entry." ::={tpSnmpRmonHistoryCtrlEntry 1} tpSnmpRmonHistoryCtrlSourcePort OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The port from which the history samples were taken. Specify the port in form of 1/0/1." ::={tpSnmpRmonHistoryCtrlEntry 2} tpSnmpRmonHistoryCtrlInterval OBJECT-TYPE SYNTAX INTEGER(10..3600) MAX-ACCESS read-write STATUS current DESCRIPTION " The interval to take samplings from the port. 10sec-3600sec." ::={tpSnmpRmonHistoryCtrlEntry 3} tpSnmpRmonHistoryCtrlBucketsRequested OBJECT-TYPE SYNTAX INTEGER(1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The requested number of discrete time intervals over which data is to be saved in the part of the media-specific table associated with this historyControlEntry. " ::= { tpSnmpRmonHistoryCtrlEntry 4 } tpSnmpRmonHistoryCtrlOwner OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the device or user that defined the entry." ::={tpSnmpRmonHistoryCtrlEntry 5} tpSnmpRmonHistoryCtrlStatus OBJECT-TYPE SYNTAX INTEGER{ disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable the corresponding sampling entry. disable(0), disable the history entry. enable(1), enable the history entry." ::={tpSnmpRmonHistoryCtrlEntry 6} tpSnmpRmonHistoryDataTable OBJECT-TYPE SYNTAX SEQUENCE OF TPSNMPRMONHISTORYDATAENTRY MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of SNMP RMON hisotry data entries." ::= {tpSnmpRmonHistoryCtrl 2} tpSnmpRmonHistoryDataEntry OBJECT-TYPE SYNTAX TPSNMPRMONHISTORYDATAENTRY MAX-ACCESS not-accessible STATUS current DESCRIPTION "Contains of the history data for a control entry" INDEX { tpSnmpRmonHistoryDataIndex } ::= { tpSnmpRmonHistoryDataTable 1 } TPSNMPRMONHISTORYDATAENTRY ::= SEQUENCE { tpSnmpRmonHistoryDataIndex INTEGER, tpSnmpRmonHistoryDataSampleIndex INTEGER, tpSnmpRmonHistoryDataIntervalStart TimeTicks, tpSnmpRmonHistoryDataDropEvents Counter32, tpSnmpRmonHistoryDataOctets Counter32, tpSnmpRmonHistoryDataPkts Counter32, tpSnmpRmonHistoryDataBroadcastPkts Counter32, tpSnmpRmonHistoryDataMulticastPkts Counter32, tpSnmpRmonHistoryDataCRCAlignErrors Counter32, tpSnmpRmonHistoryDataUndersizePkts Counter32, tpSnmpRmonHistoryDataOversizePkts Counter32, tpSnmpRmonHistoryDataFragments Counter32, tpSnmpRmonHistoryDataJabbers Counter32, tpSnmpRmonHistoryDataCollisions Counter32, tpSnmpRmonHistoryDataUtilization INTEGER } tpSnmpRmonHistoryDataIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "index" ::= { tpSnmpRmonHistoryDataEntry 1 } tpSnmpRmonHistoryDataSampleIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely identifies the particular sample this entry represents among all samples associated with the same historyControlEntry. This index starts at 1 and increases by one as each new sample is taken." ::= { tpSnmpRmonHistoryDataEntry 2 } tpSnmpRmonHistoryDataIntervalStart OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION " The value of sysUpTime at the start of the interval over which this sample was measured. If the probe keeps track of the time of day, it should start the first sample of the history at a time such that when the next hour of the day begins, a sample is started at that instant. Note that following this rule may require the probe to delay collecting the first sample of the history, as each sample must be of the same interval. Also note that the sample which is currently being collected is not accessible in this table until the end of its interval." ::= { tpSnmpRmonHistoryDataEntry 3 } tpSnmpRmonHistoryDataDropEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " The total number of events in which packets were dropped by the probe due to lack of resources during this sampling interval. Note that this number is not necessarily the number of packets dropped, it is just the number of times this condition has been detected." ::= { tpSnmpRmonHistoryDataEntry 4 } tpSnmpRmonHistoryDataOctets OBJECT-TYPE SYNTAX Counter32 UNITS "Octets" MAX-ACCESS read-only STATUS current DESCRIPTION " The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets)" ::= { tpSnmpRmonHistoryDataEntry 5 } tpSnmpRmonHistoryDataPkts OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION " The number of packets (including bad packets) received during this sampling interval." ::= { tpSnmpRmonHistoryDataEntry 6 } tpSnmpRmonHistoryDataBroadcastPkts OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION " The number of good packets received during this sampling interval that were directed to the broadcast address." ::= { tpSnmpRmonHistoryDataEntry 7 } tpSnmpRmonHistoryDataMulticastPkts OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION " The number of good packets received during this sampling interval that were directed to the broadcast address." ::= { tpSnmpRmonHistoryDataEntry 8 } tpSnmpRmonHistoryDataCRCAlignErrors OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION " The number of packets received during this sampling interval that had a length (excluding framing bits but including FCS octets) between 64 and 1518 octets, inclusive, but had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error)." ::= { tpSnmpRmonHistoryDataEntry 9 } tpSnmpRmonHistoryDataUndersizePkts OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION " The number of packets received during this sampling interval that were less than 64 octets long (excluding framing bits but including FCS octets) and were otherwise well formed." ::= { tpSnmpRmonHistoryDataEntry 10 } tpSnmpRmonHistoryDataOversizePkts OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION " The number of packets received during this sampling interval that were longer than 1518 octets (excluding framing bits but including FCS octets) but were otherwise well formed." ::= { tpSnmpRmonHistoryDataEntry 11 } tpSnmpRmonHistoryDataFragments OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION " The total number of packets received during this sampling interval that were less than 64 octets in length (excluding framing bits but including FCS octets) had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error)." ::= { tpSnmpRmonHistoryDataEntry 12 } tpSnmpRmonHistoryDataJabbers OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION " The number of packets received during this sampling interval that were longer than 1518 octets (excluding framing bits but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error)." ::= { tpSnmpRmonHistoryDataEntry 13 } tpSnmpRmonHistoryDataCollisions OBJECT-TYPE SYNTAX Counter32 UNITS "Collisions" MAX-ACCESS read-only STATUS current DESCRIPTION " The number of collion received during this sampling interval that" ::= { tpSnmpRmonHistoryDataEntry 14 } tpSnmpRmonHistoryDataUtilization OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION " The best estimate of the mean physical layer network utilization on this interface during this sampling interval, in hundredths of a percent." ::= { tpSnmpRmonHistoryDataEntry 15 } --****************** --Event --****************** tpSnmpRmonEventCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF TPSNMPRMONEVENTCTRLENTRY MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of SNMP RMON EVENT control entries." ::= {tpSnmpRmonEventCtrl 1} tpSnmpRmonEventCtrlEntry OBJECT-TYPE SYNTAX TPSNMPRMONEVENTCTRLENTRY MAX-ACCESS not-accessible STATUS current DESCRIPTION " RMON (Remote Monitoring), basing on SNMP (Simple Network Management Protocol) architecture, functions to monitor the network. Event Group, as one of the commonly used RMON Groups, is used to define RMON events. Alarms occur when an event is detected." INDEX { tpSnmpRmonEventCtrlIndex } ::= { tpSnmpRmonEventCtrlTable 1 } TPSNMPRMONEVENTCTRLENTRY ::= SEQUENCE { tpSnmpRmonEventCtrlIndex INTEGER, tpSnmpRmonEventCtrlUserName OCTET STRING, tpSnmpRmonEventCtrlDesc OCTET STRING, tpSnmpRmonEventCtrlType INTEGER, tpSnmpRmonEventCtrlOwner OCTET STRING, tpSnmpRmonEventCtrlStatus INTEGER } tpSnmpRmonEventCtrlIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The index of this entry." ::={tpSnmpRmonEventCtrlEntry 1} tpSnmpRmonEventCtrlUserName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the User or the community to which the event belongs." ::={tpSnmpRmonEventCtrlEntry 2} tpSnmpRmonEventCtrlDesc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "Description which is given to the event for identification." ::={tpSnmpRmonEventCtrlEntry 3} tpSnmpRmonEventCtrlType OBJECT-TYPE SYNTAX INTEGER{ none(1), log(2), snmptrap(3), logandtrap(4) } MAX-ACCESS read-write STATUS current DESCRIPTION " The event type, which determines the act way of the network device in response to an event. none(1),no processing. log(2),logging the event. snmptrap(3),sending trap messages to the management station. logandtrap(4),logging the event and sending trap messages to the management station." ::={tpSnmpRmonEventCtrlEntry 4} tpSnmpRmonEventCtrlOwner OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the device or user that defined the entry." ::={tpSnmpRmonEventCtrlEntry 5} tpSnmpRmonEventCtrlStatus OBJECT-TYPE SYNTAX INTEGER{ disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable the corresponding event entry. disable(0),disable the event entry. enable(1),enable the event entry. " ::={tpSnmpRmonEventCtrlEntry 6} tpSnmpRmonEventLogTable OBJECT-TYPE SYNTAX SEQUENCE OF TPSNMPRMONEVENTLOGENTRY MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of log that have been logged." ::= { tpSnmpRmonEventCtrl 2 } tpSnmpRmonEventLogEntry OBJECT-TYPE SYNTAX TPSNMPRMONEVENTLOGENTRY MAX-ACCESS not-accessible STATUS current DESCRIPTION " A set of data describing an event that has been logged. For example, an instance of the logDescription object might be named logDescription.6.47" INDEX { tpSnmpRmonEventLogEventIndex, tpSnmpRmonEventLogIndex } ::= { tpSnmpRmonEventLogTable 1 } TPSNMPRMONEVENTLOGENTRY ::= SEQUENCE { tpSnmpRmonEventLogEventIndex INTEGER, tpSnmpRmonEventLogIndex INTEGER, tpSnmpRmonEventLogTime TimeTicks, tpSnmpRmonEventLogDescription OCTET STRING } tpSnmpRmonEventLogEventIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " The event entry that generated this log entry. The log identified by a particular value of this index is associated with the same eventEntry as identified by the same value of eventIndex." ::= { tpSnmpRmonEventLogEntry 1 } tpSnmpRmonEventLogIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION " An index that uniquely identifies an entry in the log table amongst those generated by the same eventEntries. These indexes are assigned beginning with 1 and increase by one with each new log entry. The association between values of logIndex and logEntries is fixed for the lifetime of each logEntry. The agent may choose to delete the oldest instances of logEntry as required because of lack of memory. It is an implementation-specific matter as to when this deletion may occur." ::= { tpSnmpRmonEventLogEntry 2 } tpSnmpRmonEventLogTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when this log entry was created." ::= { tpSnmpRmonEventLogEntry 3 } tpSnmpRmonEventLogDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION " An implementation dependent description of the event that activated this log entry." ::= { tpSnmpRmonEventLogEntry 4 } --****************** --Alarm --****************** tpSnmpRmonAlarmCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF TPSNMPRMONALARMCTRLENTRY MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of SNMP RMON EVENT control entries." ::= {tpSnmpRmonAlarmCtrl 1} tpSnmpRmonAlarmCtrlEntry OBJECT-TYPE SYNTAX TPSNMPRMONALARMCTRLENTRY MAX-ACCESS not-accessible STATUS current DESCRIPTION " Alarm Group is one of the commonly used RMON Groups. RMON alarm management allows monitoring the specific alarm variables. When the value of a monitored variable exceeds the threshold, an alarm event is generated, which triggers the switch to act in the set way." INDEX { tpSnmpRmonAlarmCtrlIndex } ::= { tpSnmpRmonAlarmCtrlTable 1 } TPSNMPRMONALARMCTRLENTRY ::= SEQUENCE { tpSnmpRmonAlarmCtrlIndex INTEGER, tpSnmpRmonAlarmCtrlVariable INTEGER, tpSnmpRmonAlarmCtrlStatisticsIndex INTEGER, tpSnmpRmonAlarmCtrlSampleType INTEGER, tpSnmpRmonAlarmCtrlRisingThreshold INTEGER, tpSnmpRmonAlarmCtrlRisingEvent INTEGER, tpSnmpRmonAlarmCtrlFallingThreshold INTEGER, tpSnmpRmonAlarmCtrlFallingEvent INTEGER, tpSnmpRmonAlarmCtrlStartUp INTEGER, tpSnmpRmonAlarmCtrlInterval INTEGER, tpSnmpRmonAlarmCtrlOwner OCTET STRING, tpSnmpRmonAlarmCtrlStatus INTEGER } tpSnmpRmonAlarmCtrlIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The index of this entry." ::={tpSnmpRmonAlarmCtrlEntry 1} tpSnmpRmonAlarmCtrlVariable OBJECT-TYPE SYNTAX INTEGER{ recBytes(4), recPackets(5), bPackets(6), mPackets(7), crcAlignErr(8), undersize(9), oversize(10), jabbers(12), collisions(13), packet64Bytes(14), packetFrom65to127(15), packetFrom128to255(16), packetFrom256to511(17), packetFrom512to1023(18), packetFrom1024to1518(19) } MAX-ACCESS read-write STATUS current DESCRIPTION "The packet type that to be count." ::={tpSnmpRmonAlarmCtrlEntry 2} tpSnmpRmonAlarmCtrlStatisticsIndex OBJECT-TYPE SYNTAX INTEGER(1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The index of the statistics entry relative with this alarm entry." ::={tpSnmpRmonAlarmCtrlEntry 3} tpSnmpRmonAlarmCtrlSampleType OBJECT-TYPE SYNTAX INTEGER{ absoluteValue(1), deltaValue(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " The method of sampling the selected variable and calculating the value to be compared against the thresholds. absoluteValue(1),compares the values directly with the thresholds at the end of the sampling interval. deltaValue(2),subtracts the last sampled value from the current value. The difference in the values is compared to the threshold." ::={tpSnmpRmonAlarmCtrlEntry 4} tpSnmpRmonAlarmCtrlRisingThreshold OBJECT-TYPE SYNTAX INTEGER(1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The rising counter value that triggers the rise hold alarm." ::={tpSnmpRmonAlarmCtrlEntry 5} tpSnmpRmonAlarmCtrlRisingEvent OBJECT-TYPE SYNTAX INTEGER(1..12) MAX-ACCESS read-write STATUS current DESCRIPTION " The index of the corresponding event which will be triggered if the sampled value is larger than the Rise Hold." ::={tpSnmpRmonAlarmCtrlEntry 6} tpSnmpRmonAlarmCtrlFallingThreshold OBJECT-TYPE SYNTAX INTEGER(1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The falling counter value that triggers the fall hold alarm." ::={tpSnmpRmonAlarmCtrlEntry 7} tpSnmpRmonAlarmCtrlFallingEvent OBJECT-TYPE SYNTAX INTEGER(1..12) MAX-ACCESS read-write STATUS current DESCRIPTION " The index of the corresponding event which will be triggered if the sampled value is lower than the Fall Hold. " ::={tpSnmpRmonAlarmCtrlEntry 8} tpSnmpRmonAlarmCtrlStartUp OBJECT-TYPE SYNTAX INTEGER { risingAlarm(1), fallingAlarm(2), risingOrFallingAlarm(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the type of the alarm. risingAlarm(1),When the sampled value exceeds the Rise Hold, an alarm event is triggered. fallingAlarm(2),When the sampled value is under the Fall Hold, an alarm event is triggered. risingOrFallingAlarm(3),The alarm event will be triggered either the sampled value exceeds the Rise Hold or is under the Fall Hold." ::={tpSnmpRmonAlarmCtrlEntry 9} tpSnmpRmonAlarmCtrlInterval OBJECT-TYPE SYNTAX INTEGER(10..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "The alarm interval time in seconds. 10sec-3600sec." ::={tpSnmpRmonAlarmCtrlEntry 10} tpSnmpRmonAlarmCtrlOwner OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the device or user that defined the entry." ::={tpSnmpRmonAlarmCtrlEntry 11} tpSnmpRmonAlarmCtrlStatus OBJECT-TYPE SYNTAX INTEGER{ disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable the corresponding alarm entry. disable(0),disable the alarm entry. enable(1),enable the alarm entry" ::={tpSnmpRmonAlarmCtrlEntry 12} END