--SupermicroDOT11u Proprietary MIB Definition -- /***************************************************************** -- * * -- * $RCSfile: dot11u.mib,v $ * -- * * -- * $Date: 2013/04/06 13:16:44 $ * -- * * -- * $Revision: 1.2 $ * -- * * -- ****************************************************************/ -- SupermicroDOT11 and DOT11u MIBs. -- The MIB contains scalars used to configure SupermicroDOT11 functionally. SUPERMICRO-DOT11u-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY, IpAddress, Counter32, Integer32, enterprises FROM SNMPv2-SMI DisplayString, TruthValue, RowStatus, MacAddress FROM SNMPv2-TC; dot11MIB MODULE-IDENTITY LAST-UPDATED "201212200000Z" ORGANIZATION "Super Micro Computer Inc." CONTACT-INFO "Super Micro Computer Inc. E-mail:support@Supermicro.com" DESCRIPTION "This proprietary MIB for Supermicro Dot11u is for IEEE 802.11u standard entities." REVISION "201212200000Z" DESCRIPTION " This mib module is for Supermicro Dot11u module" ::= { enterprises supermicro-computer-inc(10876) super-switch(101) basic(2) 78} dot11MIBObjects OBJECT IDENTIFIER ::= { dot11MIB 1 } -- ------------------------------------------------------------- -- groups in the dot11u MIB -- ------------------------------------------------------------- dot11GASAdvertisement OBJECT IDENTIFIER ::= { dot11MIBObjects 1 } dot11StationConfig OBJECT IDENTIFIER ::= { dot11MIBObjects 2 } -- ------------------------------------------------------------- dot11StationConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11StationConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Station Configuration attributes. In tablular form to allow for multiple instances on an agent." ::= { dot11StationConfig 1 } dot11StationConfigEntry OBJECT-TYPE SYNTAX Dot11StationConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11StationConfigTable. It is possible for there to be multiple IEEE 802.11 interfaces on one agent, each with its unique MAC address. The relationship between an IEEE 802.11 interface and an interface in the context of the Internet-standard MIB is one-to-one. As such, the value of an ifIndex object instance can be directly used to identify corresponding instances of the objects defined herein. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11StationConfigTable 1 } Dot11StationConfigEntry ::= SEQUENCE { ifIndex INTEGER, dot11InterworkingServiceImplemented TruthValue, dot11InterworkingServiceActivated TruthValue, dot11QosmapImplemented TruthValue, dot11QosMapActivated TruthValue, dot11EBRImplemented TruthValue, dot11EBRActivated TruthValue, dot11ESNetwork TruthValue, dot11SSPNInterfaceImplemented TruthValue, dot11SSPNInterfaceActivated TruthValue, dot11HESSID MacAddress, dot11EASImplemented TruthValue, dot11EASActivated TruthValue, dot11MSGCFImplemented TruthValue, dot11MSGCFActivated TruthValue, dot11StationID MacAddress, dot11MediumOccupancyLimit INTEGER , dot11CFPollable TruthValue, dot11CFPPeriod INTEGER, dot11CFPMaxDuration INTEGER, dot11AuthenticationResponseTimeOut Unsigned32, dot11PrivacyOptionImplemented TruthValue, dot11PowerManagementMode INTEGER, dot11DesiredSSID OCTET STRING, dot11DesiredBSSType INTEGER, dot11OperationalRateSet OCTET STRING, dot11BeaconPeriod INTEGER, dot11DTIMPeriod INTEGER, dot11AssociationResponseTimeOut Unsigned32, dot11DisassociateReason INTEGER, dot11DisassociateStation MacAddress, dot11DeauthenticateReason INTEGER, dot11DeauthenticateStation MacAddress, dot11AuthenticateFailStatus INTEGER, dot11AuthenticateFailStation MacAddress, dot11MultiDomainCapabilityImplemented TruthValue, dot11MultiDomainCapabilityEnabled TruthValue, dot11CountryString OCTET STRING } -- HS Group -- This group defines objects for DOT11 and DOT11u. ifIndex OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The one octet identification number for the GAS Advertisement Protocol, as defined in Table7-43bi, for which statistics are stored the logical row of the GASAdvertisement table." ::= { dot11StationConfigEntry 1 } dot11InterworkingServiceImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute when true, indicates the STA is capable of interworking with external networks. A STA setting this to TRUE implements Interworking Service. When this is false, the STA does not implement Interworking Service." DEFVAL {true} ::= { dot11StationConfigEntry 2 } dot11InterworkingServiceActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute when true, indicates the STA is capable of interworking with external networks. A STA setting this to TRUE implements Interworking Service. When this is false, the STA does not implement Interworking Service." DEFVAL {true} ::= { dot11StationConfigEntry 3 } dot11QosmapImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute available at STAs, when true, indicates the STA is capable of supporting the QoS Map procedures. When this is set to FALSE, the STA does not implement QoS Map procedures.." DEFVAL {false} ::= { dot11StationConfigEntry 4 } dot11QosMapActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION ".This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates the capability of the TA to support QoS Map procedures is enabled. The capability s disabled otherwise.." DEFVAL {false} ::= { dot11StationConfigEntry 5 } dot11EBRImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. ts value is determined by device capabilities. his attribute available at STAs, when true, indicates the TA is capable of supporting Expedited Bandwidth Request rocedures. When this is false, the STA does not implement xpedited Bandwidth Request procedures.." DEFVAL {false} ::= { dot11StationConfigEntry 6 } dot11EBRActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. t is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. his attribute, when true, indicates the capability of the TA to support Expedited Bandwidth Request procedures is nabled. The capability is disabled otherwise.." DEFVAL {false} ::= { dot11StationConfigEntry 7} dot11ESNetwork OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. t is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. he Emergency Services Access Network Type set to TRUE ndicates that the BSS is used exclusively for the purposes of accessing emergency services. This object is not used by non-AP STAs.." ::= { dot11StationConfigEntry 8 } dot11SSPNInterfaceImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION ".This is a capability variable. Its value is determined by device capabilities. This attribute when true, indicates the AP is capable of SSPN Interface service. When this is false, the STA does not implement SSPN Interface Service. This object is not used by non-AP STAs. The default value of this attribute is false.." DEFVAL {false} ::= { dot11StationConfigEntry 9 } dot11SSPNInterfaceActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION ".This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates the capability of the AP to provide SSPN Interface service is enabled. The capability is disabled, otherwise. The default value of this attribute is false.." DEFVAL {false} ::= { dot11StationConfigEntry 10 } dot11HESSID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION ".This is a control variable. It is written by an external management entity or the SME. Changes take effect for the next MLME-Start.request primitive. This attribute is used by an AP and is the 6-octet homogeneous ESS identifier field, whose value is set to one of the BSSIDs in the ESS. It is required that the same value of HESSID be used for all BSSs in the homogeneous ESS.." ::= { dot11StationConfigEntry 11 } dot11EASImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION ".This is a capability variable. Its value is determined by device capabilities. This attribute when true, indicates the STA is capable of emergency alert system notification with external networks. A STA setting this to TRUE implements emergency alert system notification. When this is false, the STA does not implement emergency alert system notification.." DEFVAL {false} ::= { dot11StationConfigEntry 12 } dot11EASActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical This attribute when true, indicates the STA is capable of supporting emergency alert system. The capability is disabled otherwise.." DEFVAL {false} ::= { dot11StationConfigEntry 13 } dot11MSGCFImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute when true, indicates the non-AP STA is capable of supporting the MSGCF procedures defined in 11B. When false, the non-AP STA does not implement MSGCF procedures. This object is not used by APs. The default value of this attribute is false.." DEFVAL {false} ::= { dot11StationConfigEntry 14 } dot11MSGCFActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates the capability of the non- AP STA to provide the MSGCF is enabled. The capability is disabled, otherwise. The default value of this attribute is false.." DEFVAL {false} ::= { dot11StationConfigEntry 15 } dot11StationID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS deprecated DESCRIPTION "The purpose of dot11StationID is to allow a manager to identify a station for its own purposes. This attribute provides for that eventuality while keeping the true MAC address independent. Its syntax is MAC address and default value is the station's assigned, unique MAC address." ::= { dot11StationConfigEntry 16 } dot11MediumOccupancyLimit OBJECT-TYPE SYNTAX INTEGER(0..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall indicate the maximum amount of time, in TU, that a point coordinator may control the usage of the wireless medium without relinquishing control for long enough to allow at least one instance of DCF access to the medium. The default value of this attribute shall be 100, and the maximum value shall be 1000." ::= { dot11StationConfigEntry 17 } dot11CFPollable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "When this attribute is true, it shall indicate that the STA is able to respond to a CF-Poll with a data frame within a SIFS time. This attribute shall be false if the STA is not able to respond to a CF-Poll with a data frame within a SIFS time." ::= { dot11StationConfigEntry 18 } dot11CFPPeriod OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The attribute shall describe the number of DTIM intervals between the start of CFPs. It is modified by MLME-START.request primitive." ::= { dot11StationConfigEntry 19 } dot11CFPMaxDuration OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The attribute shall describe the maximum duration of the CFP in TU that may be generated by the PCF. It is modified by MLME-START.request primitive." ::= { dot11StationConfigEntry 20 } dot11AuthenticationResponseTimeOut OBJECT-TYPE -- SYNTAX INTEGER (1..4294967295) SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the number of TU that a responding STA should wait for the next frame in the authentication sequence." ::= { dot11StationConfigEntry 21 } dot11PrivacyOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute, when true, shall indicate that the IEEE 802.11 WEP option is implemented. The default value of this attribute shall be false." ::= { dot11StationConfigEntry 22 } dot11PowerManagementMode OBJECT-TYPE SYNTAX INTEGER { active(1), powersave(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the power management mode of the STA. When set to active, it shall indicate that the station is not in power-save mode. When set to powersave, it shall indicate that the station is in power-save mode. The power management mode is transmitted in all frames according to the rules in 7.1.3.1.7." ::= { dot11StationConfigEntry 23 } dot11DesiredSSID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute reflects the Service Set ID used in the DesiredSSID parameter of the most recent MLME_Scan.request. This value may be modified by an external management entity and used by the local SME to make decisions about the Scanning process." ::= { dot11StationConfigEntry 24 } dot11DesiredBSSType OBJECT-TYPE SYNTAX INTEGER { infrastructure(1), independent(2), any(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the type of BSS the station shall use when scanning for a BSS with which to synchronize. This value is used to filter Probe Response frames and Beacons. When set to infrastructure, the station shall only synchronize with a BSS whose Capability Information field has the ESS subfield set to 1. When set to independent, the station shall only synchronize with a BSS whose Capability Information field has the IBSS subfield set to 1. When set to any, the station may synchronize to either type of BSS." ::= { dot11StationConfigEntry 25 } dot11OperationalRateSet OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..126)) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the set of data rates at which the station may transmit data. Each octet contains a value representing a rate. Each rate shall be within the range from 2 to 127, corresponding to data rates in increments of 500 kb/s from 1 Mb/s to 63.5 Mb/s, and shall be supported (as indicated in the supported rates table) for receiving data. This value is reported in transmitted Beacon, Probe Request, Probe Response, Association Request, Association Response, Reassociation Request, and Reassociation Response frames, and is used to determine whether a BSS with which the station desires to synchronize is suitable. It is also used when starting a BSS, as specified in 10.3." ::= { dot11StationConfigEntry 26 } dot11BeaconPeriod OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the number of TU that a station shall use for scheduling Beacon transmissions. This value is transmitted in Beacon and Probe Response frames." ::= { dot11StationConfigEntry 27 } dot11DTIMPeriod OBJECT-TYPE SYNTAX INTEGER(1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the number of beacon intervals that shall elapse between transmission of Beacons frames containing a TIM element whose DTIM Count field is 0. This value is transmitted in the DTIM Period field of Beacon frames." ::= { dot11StationConfigEntry 28 } dot11AssociationResponseTimeOut OBJECT-TYPE -- SYNTAX INTEGER(1..4294967295) SYNTAX Unsigned32(1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the number of TU that a requesting STA should wait for a response to a transmitted association-request MMPDU." ::= { dot11StationConfigEntry 29 } dot11DisassociateReason OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute holds the most recently transmitted Reason Code in a Disassociation frame. If no Disassociation frame has been transmitted, the value of this attribute shall be 0." -- REFERENCE "IEEE Std 802.11-1997, 7.3.1.7" ::= { dot11StationConfigEntry 30 } dot11DisassociateStation OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute holds the MAC address from the Address 1 field of the most recently transmitted Disassociation frame. If no Disassociation frame has been transmitted, the value of this attribute shall be 0." ::= { dot11StationConfigEntry 31 } dot11DeauthenticateReason OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute holds the most recently transmitted Reason Code in a Deauthentication frame. If no Deauthentication frame has been transmitted, the value of this attribute shall be 0." -- REFERENCE "IEEE Std 802.11-1997, 7.3.1.7" ::= { dot11StationConfigEntry 32 } dot11DeauthenticateStation OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute holds the MAC address from the Address 1 field of the most recently transmitted Deauthentication frame. If no Deauthentication frame has been transmitted, the value of this attribute shall be 0." ::= { dot11StationConfigEntry 33 } dot11AuthenticateFailStatus OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute holds the most recently transmitted Status Code in a failed Authentication frame. If no failed Athentication frame has been transmitted, the value of this attribute shall be 0." -- REFERENCE "IEEE Std 802.11-1997, 7.3.1.9" ::= { dot11StationConfigEntry 34 } dot11AuthenticateFailStation OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute holds the MAC address from the Address 1 field of the most recently transmitted failed Authentication frame. If no failed Authentication frame has been transmitted, the value of this attribute shall be 0." ::= { dot11StationConfigEntry 35 } dot11MultiDomainCapabilityImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute, when TRUE, indicates that the station implementation is capable of supporting multiple re gulatory domains. The capability is disabled, otherwise. The default value of this attribute is FALSE." ::= { dot11StationConfigEntry 36 } dot11MultiDomainCapabilityEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute, when TRUE, indicates that the capability of the station to operate in multiple regulatory domains is enabled. The capability is disabled, otherwise. The default value of this attribute is FALSE." ::= { dot11StationConfigEntry 37 } dot11CountryString OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute identifies the country in which the station is operating. The first two octets if this string is the two character country code as described in document ISO/IEC 3166-1. The third octet shall be one of the following: 1. an ASCII space character, if the regulations under which the station is operating encompass all environments in the country, 2. an ASCII Ocharacter, if the regulations under which the station is operating are for an Outdoor environment only, or 3. an ASCII Icharacter, if the regulations under which the station is operating are for an Indoor environment only." ::= { dot11StationConfigEntry 38 } -- ------------------------------------------------------------- -- the dot11GASAdvertisementTable group -- ------------------------------------------------------------- dot11GASAdvertisementTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11GASAdvertisementEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is a table of GAS counters that allows for multiple instantiations of those counters on an STA." ::= { dot11GASAdvertisement 1 } dot11GASAdvertisementEntry OBJECT-TYPE SYNTAX Dot11GASAdvertisementEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object provides the attributes identifying a GAS counter within an STA." INDEX { dot11GASAdvertisementId } ::= { dot11GASAdvertisementTable 1 } Dot11GASAdvertisementEntry ::= SEQUENCE { dot11GASAdvertisementId INTEGER, dot11GASPauseForServerResponse TruthValue, dot11GASResponseTimeout INTEGER, dot11GASComebackDelay INTEGER, dot11GASResponseBufferingTime INTEGER, dot11GASQueryResponseLengthLimit INTEGER, dot11GASQueries Counter32, dot11GASQueryRate Unsigned32, dot11GASResponses Counter32, dot11GASResponseRate Unsigned32, dot11GASTransmittedFragmentCount Counter32, dot11GASReceivedFragmentCount Counter32, dot11GASNoRequestOutstanding Counter32, dot11GASResponsesDiscarded Counter32, dot11GASFailedResponses Counter32 } -- HS Group -- This group defines objects for DOT11 and DOT11u. dot11GASAdvertisementId OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The one octet identification number for the GAS Advertisement Protocol, as defined in Table7-43bi, for which statistics are stored the logical row of the GASAdvertisement table." ::= { dot11GASAdvertisementEntry 1 } dot11GASPauseForServerResponse OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute is only used by the responding STA in a GAS exchange. When true, it indicates that the responding STA will not transmit a GAS Initial Response frame until it receives the query response from the Advertisement Server or a timeout occurs. When false, the STA will not wait for a response from the Advertisement Server before transmiting the GAS Initial Response frame." DEFVAL {false} ::= { dot11GASAdvertisementEntry 2 } dot11GASResponseTimeout OBJECT-TYPE SYNTAX INTEGER (1000..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This parameter shall indicate the GAS response timeout value in TUs." DEFVAL {5000} ::= { dot11GASAdvertisementEntry 3 } dot11GASComebackDelay OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This object identifies the GAS Comeback Delay (in TUs) to be used for this Advertisement Protocol" DEFVAL {1000} ::= { dot11GASAdvertisementEntry 4 } dot11GASResponseBufferingTime OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This object defines the time duration after the expiry of the GAS Comeback Delay that an STA will buffer a Query Response. The units of this MIB object are TUs. Upon expiry of this time, the STA may discard the Query Response." DEFVAL {1000} ::= { dot11GASAdvertisementEntry 5 } dot11GASQueryResponseLengthLimit OBJECT-TYPE SYNTAX INTEGER (1..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This object indicates the maximum number of octets an AP will transmit in one or more Query Response fields contained within GAS Comeback Response frame(s). A value of 127 means the maximum limit enforced is contained by the maximum allowable number of fragments in the GAS Query Fragment Response ID" ::= { dot11GASAdvertisementEntry 6 } dot11GASQueries OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after transmission of a MLME- GAS.request or MLME-PDGAS.request or receipt of an MLME- GAS.indication or MLME-PDGAS.indication primitive. The number of GAS queries sent or received for the protocol identified by dot11GASAdvertisementId." ::= { dot11GASAdvertisementEntry 7 } dot11GASQueryRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is updated by the SME after receipt of an MLME- GAS.indication or MLME-PDGAS.indication primitive. The number of GAS queries per minute received for the protocol identified by dot11GASAdvertisementId, averaged over the previous ten minutes." ::= { dot11GASAdvertisementEntry 8 } dot11GASResponses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after transmission of a MLME- GAS.response or MLME-PDGAS.response or receipt of an MLME- GAS.confirm or MLME-PDGAS.confirm primitive. The number of GAS responses sent or received for the protocol identified by dot11GASAdvertisementId." ::= { dot11GASAdvertisementEntry 9 } dot11GASResponseRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is updated by the SME after transmission of an MLME- GAS.response or MLME-PDGAS.response primitive. The number of responses to GAS queries per minute transmitted by an AP for the protocol identified by dot11GASAdvertisementId, averaged over the previous ten minutes. This MIB variable is not used in non-AP STAs." ::= { dot11GASAdvertisementEntry 10 } dot11GASTransmittedFragmentCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is updated by the SME after transmission of an MLME- GAS.response or MLME-PDGAS.response primitive. This counter shall be incremented for an acknowledged GAS MMPDU for the protocol identified by dot11GASAdvertisementId." ::= { dot11GASAdvertisementEntry 11 } dot11GASReceivedFragmentCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is updated by the MAC after transmission of an MLME- GAS.confirm or MLME-PDGAS.confirm primitive. This counter shall be incremented for each successfully received MMPDU of type Data" ::= { dot11GASAdvertisementEntry 12 } dot11GASNoRequestOutstanding OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is updated by the SME after transmission of an MLME-GAS.response or MLME-PDGAS.response primitive. This counter shall be incremented each time a STA returns a status code of no request outstanding in a GAS Initial Response or GAS Comeback Response frame for the protocol identified by dot11GASAdvertisementId." ::= { dot11GASAdvertisementEntry 13 } dot11GASResponsesDiscarded OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is updated by the SME after transmission of an MLME-GAS.response or MLME-PDGAS.response primitive. This counter shall be incremented each a STA discards a GAS response due to the expiry of the dot11GASResponseBufferingTime timer for the protocol identified by dot11GASAdvertisementId." ::= { dot11GASAdvertisementEntry 14 } dot11GASFailedResponses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is updated by the SME after transmission of an MLME-GAS.response or MLME-PDGAS.response primitive. This counter shall be incremented each time a STA commences transmitting a GAS response but fails to successfully complete the transmission of all GAS fragments in that response due to the expiry of the dot11GASResponseTimeout timer for the protocol identified by dot11GASAdvertisementId." ::= { dot11GASAdvertisementEntry 15 } END