-- SOCOMEC SICON MIB -- MIB for Intelligent Power Management -- -- { iso org(3) dod(6) internet(1) private(4) enterprises(1) socomecSicon(4555) -- product(1) pduAgent(1) iPDU(20) -- ============================================================================================== --- --- Revision History --- --- v0.80a1 02-Apr-2012 Brian Chen/socomecSicon --- Created --- --- v0.80a2 07-Jan-2013 Brian Chen/Ingrasys --- Modified trap group --- Modified EMD trap issue. --- SOCOMECIPDU-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215; socomecSicon OBJECT IDENTIFIER ::= { enterprises 4555 } product OBJECT IDENTIFIER ::= { socomecSicon 1 } pduAgent OBJECT IDENTIFIER ::= { product 1 } iPDU OBJECT IDENTIFIER ::= { pduAgent 20 } ipduObjects OBJECT IDENTIFIER ::= { iPDU 1 } ipduTraps OBJECT IDENTIFIER ::= { iPDU 2 } ipduIdent OBJECT IDENTIFIER ::= { ipduObjects 1 } ipduAgent OBJECT IDENTIFIER ::= { ipduObjects 2 } ipduDevice OBJECT IDENTIFIER ::= { ipduObjects 3 } ipduSlave OBJECT IDENTIFIER ::= { ipduObjects 4 } ipduEnv OBJECT IDENTIFIER ::= { ipduObjects 5 } -- =========================================================================== -- -- ipduIdent -- -- iPDU Identification Group -- -- =========================================================================== ipduIdentManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of manufacturer." ::= { ipduIdent 1 } ipduIdentModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The Model designation of device." ::= { ipduIdent 2 } ipduIdentAgentSoftwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The firmware version of the device." ::= { ipduIdent 3 } ipduIdentName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A description of this device." ::= { ipduIdent 4 } ipduAgentConfig OBJECT IDENTIFIER ::= { ipduAgent 1 } -- =========================================================================== -- -- ipduConfig -- -- iPDU Configuration Group, configure the secific features of iPDU -- -- =========================================================================== ipduAgentMibVersion OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Mib Version implemented on this device." ::= { ipduAgentConfig 1 } ipduAgentTime OBJECT IDENTIFIER ::= { ipduAgent 2 } -- =========================================================================== -- -- ipduConfigTime -- -- Date/Time Configuration Group of the device. -- -- =========================================================================== ipduAgentTimeDate OBJECT-TYPE SYNTAX DisplayString (SIZE (10..10)) ACCESS read-write STATUS mandatory DESCRIPTION "The date in agent, format is (dd/mm/yyyy)" ::= { ipduAgentTime 1 } ipduAgentTimeTime OBJECT-TYPE SYNTAX DisplayString (SIZE (8..8)) ACCESS read-write STATUS mandatory DESCRIPTION "The time in agent, format is (hh:mm:ss)" ::= { ipduAgentTime 2 } ipduAgentTimerFromNtp OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the agent to synchronize date/time with NTP server." ::= { ipduAgentTime 3 } ipduAgentNtpIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The ip address of NTP server." ::= { ipduAgentTime 4 } ipduAgentNtpTimeZone OBJECT-TYPE SYNTAX INTEGER { gMT-1200(1), gMT-1100(2), gMT-1000(3), gMT-0900(4), gMT-0800(5), gMT-0700(6), gMT-0600(7), gMT-0500(8), gMT-0400(9), gMT-0330(10), gMT-0300(11), gMT-0200(12), gMT-0100(13), gMT-0000(14), gMT0100(15), gMT0200(16), gMT0300(17), gMT0330(18), gMT0400(19), gMT0500(20), gMT0530(21), gMT0600(22), gMT0700(23), gMT0800(24), gMT0900(25), gMT1000(26), gMT1100(27), gMT1200(28) } ACCESS read-write STATUS mandatory DESCRIPTION "Time Zone to use when synchronize with NTP server." ::= { ipduAgentTime 5 } ipduAgentDayLightSaving OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable the Day Light Saving when synchronize with NTP server." ::= { ipduAgentTime 6 } ipduAgentNetwork OBJECT IDENTIFIER ::= { ipduAgent 3 } -- =========================================================================== -- -- ipduConfigNetwork -- -- Network Configuration Group of the device. -- -- =========================================================================== ipduAgentNetworkIp OBJECT IDENTIFIER ::= { ipduAgentNetwork 1 } -- =========================================================================== -- -- ipduAgentNetworkIp -- -- Ip address Configuration Group of the device. -- -- =========================================================================== ipduAgentNetworkIpAdress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The ip address that NMS can identify the managed device." ::= { ipduAgentNetworkIp 1} ipduAgentNetworkIpGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The default gateway that allow device managed through routers." ::= { ipduAgentNetworkIp 2} ipduAgentNetworkIpSubnet OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Internet address subnet mask" ::= { ipduAgentNetworkIp 3} ipduAgentNetworkDhcpControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable DHCP protocol" ::= { ipduAgentNetwork 2 } ipduAgentNetworkPingControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable to response to PING request." ::= { ipduAgentNetwork 3 } ipduAgentNetworkTftpControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable TFTP protocol" ::= { ipduAgentNetwork 4 } ipduAgentNetworkTelnet OBJECT IDENTIFIER ::= { ipduAgentNetwork 5 } -- =========================================================================== -- -- ipduConfigNetworkTelnet -- -- Telnet Configuration Group of the device. -- -- =========================================================================== ipduAgentTelnetControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable Telnet protocol." ::= { ipduAgentNetworkTelnet 1 } ipduAgentTelnetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The TCP port for telnet" ::= { ipduAgentNetworkTelnet 2} ipduAgentNetworkHttp OBJECT IDENTIFIER ::= { ipduAgentNetwork 6 } -- =========================================================================== -- -- ipduConfigNetworkHttp -- -- HTTP Configuration Group of the device. -- -- =========================================================================== ipduAgentHttpControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable HTTP protocol." ::= { ipduAgentNetworkHttp 1 } ipduAgentHttpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The TCP port for HTTP." ::= { ipduAgentNetworkHttp 2} ipduAgentNetworkSnmp OBJECT IDENTIFIER ::= { ipduAgentNetwork 7 } -- =========================================================================== -- -- ipduAgentNetworkSnmp -- -- SNMP Configuration Group of the device. -- -- =========================================================================== ipduAgentSnmpControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable SNMP protocol." ::= { ipduAgentNetworkSnmp 1 } ipduAgentSnmpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The UDP port for SNMP." ::= { ipduAgentNetworkSnmp 2} ipduAgentLog OBJECT IDENTIFIER ::= { ipduAgentConfig 4 } -- =========================================================================== -- -- ipduConfigLog -- -- Log Configuration Group of the device. -- -- =========================================================================== pduAgentDataLogInterval OBJECT-TYPE SYNTAX INTEGER (60..28800) -- in seconds ACCESS read-write STATUS mandatory DESCRIPTION "The interval of the updation of the data log. The value is in seconds" ::= { ipduAgentLog 1 } ipduAgentControl OBJECT IDENTIFIER ::= { ipduAgentConfig 5 } -- =========================================================================== -- -- ipduAgentAgentControl -- -- Agent Control Configuration Group of the device. -- -- =========================================================================== ipduAgentControlDefault OBJECT-TYPE SYNTAX INTEGER { reset(1), nothing(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all parameters of the agent to default value." ::= { ipduAgentControl 1} ipduAgentControlRestart OBJECT-TYPE SYNTAX INTEGER { restart(1), nothing(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Restart the agent." ::= { ipduAgentControl 2} ipduAgentTrap OBJECT IDENTIFIER ::= { ipduAgentConfig 6 } -- =========================================================================== -- -- ipduAgentTrap -- -- Trap Configuration Group of the agent. -- -- =========================================================================== ipduAgentTrapRetryCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The count of repeat traps send to NMS before trap acknowledgement received." ::= { ipduAgentTrap 1} ipduAgentTrapRetryTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The time interval in seconds between retry traps sned to NMS." ::= { ipduAgentTrap 2} ipduAgentTrapAckSignature OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The signature of trap acknowledgement." ::= { ipduAgentTrap 3} -- =========================================================================== -- -- ipduAgentTrapsReceiversTable -- -- =========================================================================== ipduAgentTrapsReceiversTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduAgentTrapsReceiversEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of managers to send traps to. The number of entries is given by the value of agentConfigNumTrapReceivers" ::= { ipduAgentConfig 7} ipduAgentTrapsReceiversEntry OBJECT-TYPE SYNTAX IpduAgentTrapsReceiversEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The managers to send traps to." INDEX { trapsIndex } ::= { ipduAgentTrapsReceiversTable 1 } IpduAgentTrapsReceiversEntry ::= SEQUENCE { trapsIndex INTEGER, trapsReceiverAddr IpAddress, receiverCommunityString DisplayString, receiverNmsType INTEGER, receiverSeverityLevel INTEGER, receiverDescription DisplayString } trapsIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a trap receiver entry." ::= { ipduAgentTrapsReceiversEntry 1 } trapsReceiverAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the manager to send a trap to." ::= { ipduAgentTrapsReceiversEntry 2 } receiverCommunityString OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "The community name to use in the trap when sent to the manager." ::= { ipduAgentTrapsReceiversEntry 3 } receiverNmsType OBJECT-TYPE SYNTAX INTEGER { none(1), iPDU-trap(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The trap group that NMS desired." ::= { ipduAgentTrapsReceiversEntry 4 } receiverSeverityLevel OBJECT-TYPE SYNTAX INTEGER { informational(1), warning(2), severe(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The severity level of traps to be received by this manager." ::= { ipduAgentTrapsReceiversEntry 5 } receiverDescription OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "Description of trap receivers" ::= { ipduAgentTrapsReceiversEntry 6 } -- =========================================================================== -- -- ipduAgentAccessControlTable -- -- =========================================================================== ipduAgentAccessControlTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduAgentAccessControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of managers which can access the device with private community string." ::= { ipduAgentConfig 8} ipduAgentAccessControlEntry OBJECT-TYPE SYNTAX IpduAgentAccessControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The managers." INDEX { accessIndex} ::= { ipduAgentAccessControlTable 1 } IpduAgentAccessControlEntry ::= SEQUENCE { accessIndex INTEGER, accessControlAddr IpAddress, accessControlMode INTEGER } accessIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access control entry." ::= { ipduAgentAccessControlEntry 1 } accessControlAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the manager to access the device." ::= { ipduAgentAccessControlEntry 2 } accessControlMode OBJECT-TYPE SYNTAX INTEGER { permitted (1), denied (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Access type, only read/Write access type can change parameter of the device." ::= { ipduAgentAccessControlEntry 3 } ipduDeviceInlet OBJECT IDENTIFIER ::= { ipduDevice 1 } -- =========================================================================== -- -- ipduDeviceInlet -- -- Inlet Group -- -- =========================================================================== ipduDeviceInletNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The inlet number on this device." ::= { ipduDeviceInlet 1} ipduDeviceInletConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduDeviceInletConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of inlet on this device." ::= { ipduDeviceInlet 2} ipduDeviceInletConfigEntry OBJECT-TYPE SYNTAX IpduDeviceInletConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The inlet number of device." INDEX { inletConfigIndex} ::= { ipduDeviceInletConfigTable 1 } IpduDeviceInletConfigEntry ::= SEQUENCE { inletConfigIndex INTEGER, inletConfigDesc DisplayString, inletConfigVoltageHigh INTEGER, inletConfigVoltageHighAction INTEGER, inletConfigVoltageLow INTEGER, inletConfigVoltageLowAction INTEGER, inletConfigCurrentHigh INTEGER, inletConfigCurrentHighAction INTEGER, inletConfigFrequencyHigh INTEGER, inletConfigfrequencyHighAction INTEGER, inletConfigFrequencyLow INTEGER, inletConfigfrequencyLowAction INTEGER } inletConfigIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access inlet configuration table." ::= { ipduDeviceInletConfigEntry 1 } inletConfigDesc OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of inlet of device." ::= { ipduDeviceInletConfigEntry 2 } inletConfigVoltageHigh OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet high voltage threshold, in volts." ::= { ipduDeviceInletConfigEntry 3 } inletConfigVoltageHighAction OBJECT-TYPE SYNTAX INTEGER { outletsOff (1), nothing (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reaction of the device when inlet voltage higher than set point." ::= { ipduDeviceInletConfigEntry 4 } inletConfigVoltageLow OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet low voltage threshold, in volts." ::= { ipduDeviceInletConfigEntry 5 } inletConfigVoltageLowAction OBJECT-TYPE SYNTAX INTEGER { outletsOff (1), nothing (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reaction of the device when inlet voltage lower than set point." ::= { ipduDeviceInletConfigEntry 6 } inletConfigCurrentHigh OBJECT-TYPE SYNTAX INTEGER (1..160) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet low voltage threshold, in 0.1 amps." ::= { ipduDeviceInletConfigEntry 7 } inletConfigCurrentHighAction OBJECT-TYPE SYNTAX INTEGER { outletsOff (1), nothing (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reaction of the device when inlet current higher than set point." ::= { ipduDeviceInletConfigEntry 8 } inletConfigFrequencyHigh OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet high frequency threshold, in hz." ::= { ipduDeviceInletConfigEntry 9 } inletConfigfrequencyHighAction OBJECT-TYPE SYNTAX INTEGER { outletsOff (1), nothing (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reaction of the device when inlet frequency higher than set point." ::= { ipduDeviceInletConfigEntry 10 } inletConfigFrequencyLow OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet low frequency threshold, in hz." ::= { ipduDeviceInletConfigEntry 11 } inletConfigfrequencyLowAction OBJECT-TYPE SYNTAX INTEGER { outletsOff (1), nothing (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reaction of the device when inlet frequency lower than set point." ::= { ipduDeviceInletConfigEntry 12 } ipduDeviceInletStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduDeviceInletStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of inlet on this device." ::= { ipduDeviceInlet 3} ipduDeviceInletStatusEntry OBJECT-TYPE SYNTAX IpduDeviceInletStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The inlet number of device." INDEX { inletStatusIndex} ::= { ipduDeviceInletStatusTable 1 } IpduDeviceInletStatusEntry ::= SEQUENCE { inletStatusIndex INTEGER, inletStatusVoltage INTEGER, inletStatusCurrent INTEGER, inletStatusFrequency INTEGER, inletStatusKwatt INTEGER, inletStatusWH INTEGER } inletStatusIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access inlet configuration table." ::= { ipduDeviceInletStatusEntry 1 } inletStatusVoltage OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Voltage in 0.1 volts" ::= { ipduDeviceInletStatusEntry 2 } inletStatusCurrent OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Current in 0.001 Amp." ::= { ipduDeviceInletStatusEntry 3 } inletStatusFrequency OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Frequency in 0.1 Hz" ::= { ipduDeviceInletStatusEntry 4 } inletStatusKwatt OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Kwatt in 0.1 KW/H" ::= { ipduDeviceInletStatusEntry 5 } inletStatusWH OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Kwatt in 0.1 W/H" ::= { ipduDeviceInletStatusEntry 6 } inletWattReset OBJECT-TYPE SYNTAX INTEGER { none(1), inlet1(2), inlet2(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset inlet kw." ::= { ipduDeviceInlet 4} ipduDeviceOutlet OBJECT IDENTIFIER ::= { ipduDevice 2 } -- =========================================================================== -- -- ipduDeviceOutlet -- -- Inlet Group -- -- =========================================================================== ipduDeviceOutletNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet number on this device." ::= { ipduDeviceOutlet 1} ipduDeviceOutletConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduDeviceOutletConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipduDeviceOutlet 2} ipduDeviceOutletConfigEntry OBJECT-TYPE SYNTAX IpduDeviceOutletConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The inlet number of device." INDEX { inletConfigIndex} ::= { ipduDeviceOutletConfigTable 1 } IpduDeviceOutletConfigEntry ::= SEQUENCE { outletConfigIndex INTEGER, outletConfigDesc DisplayString, outletConfigLocation DisplayString, outletConfigOnDelay INTEGER, outletConfigOffDelay INTEGER, outletConfigCurrentHigh INTEGER, outletConfigCurrentHighAction INTEGER } outletConfigIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access inlet configuration table." ::= { ipduDeviceOutletConfigEntry 1 } outletConfigDesc OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of outlet of device." ::= { ipduDeviceOutletConfigEntry 2 } outletConfigLocation OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "Location of device connectted to this outlet." ::= { ipduDeviceOutletConfigEntry 3 } outletConfigOnDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduDeviceOutletConfigEntry 4 } outletConfigOffDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn off tis outlet, in seconds." ::= { ipduDeviceOutletConfigEntry 5 } outletConfigCurrentHigh OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The outlet high current threshold, in amp." ::= { ipduDeviceOutletConfigEntry 6 } outletConfigCurrentHighAction OBJECT-TYPE SYNTAX INTEGER { outletOff (1), nothing (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reaction of the device when outlet current higher than set point." ::= { ipduDeviceOutletConfigEntry 7 } ipduDeviceOutletStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduDeviceOutletStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipduDeviceOutlet 3} ipduDeviceOutletStatusEntry OBJECT-TYPE SYNTAX IpduDeviceOutletStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { outletStatusIndex} ::= { ipduDeviceOutletStatusTable 1 } IpduDeviceOutletStatusEntry ::= SEQUENCE { outletStatusIndex INTEGER, outletStatusStatus INTEGER, outletStatusCurrent INTEGER, outletStatusKwatt INTEGER, outletStatusWH INTEGER, outletStatusStateTime INTEGER, outletStatusTimeToGo INTEGER } outletStatusIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipduDeviceOutletStatusEntry 1 } outletStatusStatus OBJECT-TYPE SYNTAX INTEGER { unknow (1), outletOff (2), outletOn (3), outletOffToOn (4), outletOnToOff (5), outletCycling (6) } ACCESS read-only STATUS mandatory DESCRIPTION "Outlet state" ::= { ipduDeviceOutletStatusEntry 2 } outletStatusCurrent OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The outlet Current in 0.001 Amp." ::= { ipduDeviceOutletStatusEntry 3 } outletStatusKwatt OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The outlet Kwatt in 0.001 KW/H." ::= { ipduDeviceOutletStatusEntry 4 } outletStatusWH OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The outlet Watt in 0.1 W/H." ::= { ipduDeviceOutletStatusEntry 5 } outletStatusStateTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds since the outlet changed to current state." ::= { ipduDeviceOutletStatusEntry 6 } outletStatusTimeToGo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Remain time the outlet state will be changed by agent, in seconds" ::= { ipduDeviceOutletStatusEntry 7 } ipduDeviceOutletControlTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduDeviceOutletControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipduDeviceOutlet 4} ipduDeviceOutletControlEntry OBJECT-TYPE SYNTAX IpduDeviceOutletControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { outletControlIndex} ::= { ipduDeviceOutletControlTable 1 } IpduDeviceOutletControlEntry ::= SEQUENCE { outletControlIndex INTEGER, outletControlControl INTEGER } outletControlIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipduDeviceOutletControlEntry 1 } outletControlControl OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipduDeviceOutletControlEntry 2 } ipduDeviceOutletControlAll OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimers(6), offByActionTimers(7), cycleByActionTimers(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control all outlets perform action as requested." ::= { ipduDeviceOutlet 5} ipduDeviceOutletWattReset OBJECT-TYPE SYNTAX INTEGER { none(1), outleta(2), outletb(3), outletc(4), outletd(5), outlete(6), outletf(7), outletg(8), outleth(9), outleti(10), outletj(11), outletk(12), outletl(13) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset outlet kw." ::= { ipduDeviceOutlet 6} ipduDeviceCcOut OBJECT IDENTIFIER ::= { ipduDevice 3 } -- =========================================================================== -- -- ipduDeviceCCOut -- -- Contact Closure Output Group -- -- =========================================================================== ipduDeviceCcOutNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The contact closure output number on this device." ::= { ipduDeviceCcOut 1} ipduDeviceCcOutConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduDeviceCcOutConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of contact closure output on this device." ::= { ipduDeviceCcOut 2} ipduDeviceCcOutConfigEntry OBJECT-TYPE SYNTAX IpduDeviceCcOutConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The CC number of device." INDEX { ccOutConfigIndex} ::= { ipduDeviceCcOutConfigTable 1 } IpduDeviceCcOutConfigEntry ::= SEQUENCE { ccOutConfigIndex INTEGER, ccOutConfigDesc DisplayString, ccOutConfigEventAction INTEGER, ccOutConfigCloseDelay INTEGER, ccOutConfigOpenDelay INTEGER } ccOutConfigIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to access contact closure output configuration table." ::= { ipduDeviceCcOutConfigEntry 1 } ccOutConfigDesc OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a contact closure output of device." ::= { ipduDeviceCcOutConfigEntry 2 } ccOutConfigEventAction OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disble the contact closure output to react to events." ::= { ipduDeviceCcOutConfigEntry 3 } ccOutConfigCloseDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time in seconds when the contact closure output set to close." ::= { ipduDeviceCcOutConfigEntry 4 } ccOutConfigOpenDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time in seconds when the contact closure output set to open." ::= { ipduDeviceCcOutConfigEntry 5 } ipduDeviceCcOutStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduDeviceCcOutStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of contact closure output on this device." ::= { ipduDeviceCcOut 3} ipduDeviceCcOutStatusEntry OBJECT-TYPE SYNTAX IpduDeviceCcOutStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The CC number of device." INDEX { ccOutStatusIndex} ::= { ipduDeviceCcOutStatusTable 1 } IpduDeviceCcOutStatusEntry ::= SEQUENCE { ccOutStatusIndex INTEGER, ccOutStatusStatus INTEGER, ccOutStatusTimeOnState INTEGER } ccOutStatusIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to access contact closure output configuration table." ::= { ipduDeviceCcOutStatusEntry 1 } ccOutStatusStatus OBJECT-TYPE SYNTAX INTEGER { closed (1), open (2) } ACCESS read-only STATUS mandatory DESCRIPTION "State of a contact closure output of device." ::= { ipduDeviceCcOutStatusEntry 2 } ccOutStatusTimeOnState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds since the contact closure output changed to current state." ::= { ipduDeviceCcOutStatusEntry 3 } ipduDeviceCcOutControlTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduDeviceCcOutControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of contact closure output on this device." ::= { ipduDeviceCcOut 4} ipduDeviceCcOutControlEntry OBJECT-TYPE SYNTAX IpduDeviceCcOutControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { ccOutControlIndex} ::= { ipduDeviceCcOutControlTable 1 } IpduDeviceCcOutControlEntry ::= SEQUENCE { ccOutControlIndex INTEGER, ccOutControlControl INTEGER } ccOutControlIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access contact closure output configuration table." ::= { ipduDeviceCcOutControlEntry 1 } ccOutControlControl OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), closeImmediately(3), openImmediately(4), cycleImmediately(5), closeByCloseTimer(6), openByOpenTimer(7), cycleByActionTimer(8), closeThenOpenByActionTimers(9), openThenCloseByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the contact closure output perform action as requested." ::= { ipduDeviceCcOutControlEntry 2 } ipduSlaveState OBJECT IDENTIFIER ::= { ipduSlave 1 } -- =========================================================================== -- -- ipduSlaveState -- -- Daisy Chain Device Group -- -- =========================================================================== -- ipduSlaveStateTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduSlaveStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipduSlaveState 1} ipduSlaveStateEntry OBJECT-TYPE SYNTAX IpduSlaveStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveStateIndex} ::= { ipduSlaveStateTable 1 } IpduSlaveStateEntry ::= SEQUENCE { slaveStateIndex INTEGER, slaveStateControl01 INTEGER } slaveStateIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipduSlaveStateEntry 1 } slaveStateControl01 OBJECT-TYPE SYNTAX INTEGER { disconnected(1), connected(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested to slave outlet A" ::= { ipduSlaveStateEntry 2 } ipduSlaveInlet OBJECT IDENTIFIER ::= { ipduSlave 2 } -- =========================================================================== -- -- ipduSlaveAllDevice -- -- Daisy Chain Device Group -- -- =========================================================================== ipduSlaveInletStatus OBJECT IDENTIFIER ::= { ipduSlaveInlet 1 } -- =========================================================================== -- -- ipduSlaveAllDevice -- -- Daisy Chain Device Group -- -- =========================================================================== ipduDeviceSlaveInletStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduDeviceSlaveInletStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of inlet on this device." ::= { ipduSlaveInletStatus 1} ipduDeviceSlaveInletStatusEntry OBJECT-TYPE SYNTAX IpduDeviceSlaveInletStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The inlet number of device." INDEX { inletStatusIndex} ::= { ipduDeviceSlaveInletStatusTable 1 } IpduDeviceSlaveInletStatusEntry ::= SEQUENCE { inletSlaveStatusIndex INTEGER, inletSlaveStatusVoltage INTEGER, inletSlaveStatusCurrent INTEGER, inletSlaveStatusFrequency INTEGER, inletSlaveStatusKwatt INTEGER, inletSlaveStatusWH INTEGER, inletSlaveStatusVoltage2 INTEGER, inletSlaveStatusCurrent2 INTEGER, inletSlaveStatusFrequency2 INTEGER, inletSlaveStatusKwatt2 INTEGER, inletSlaveStatusWH2 INTEGER } inletSlaveStatusIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access inlet configuration table." ::= { ipduDeviceSlaveInletStatusEntry 1 } inletSlaveStatusVoltage OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Voltage in 0.1 volts" ::= { ipduDeviceSlaveInletStatusEntry 2 } inletSlaveStatusCurrent OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Current in 0.001 Amp." ::= { ipduDeviceSlaveInletStatusEntry 3 } inletSlaveStatusFrequency OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Frequency in 0.1 Hz" ::= { ipduDeviceSlaveInletStatusEntry 4 } inletSlaveStatusKwatt OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Kwatt in 0.001 KW/H" ::= { ipduDeviceSlaveInletStatusEntry 5 } inletSlaveStatusWH OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Kwatt in 0.001 KW/H" ::= { ipduDeviceSlaveInletStatusEntry 6 } inletSlaveStatusVoltage2 OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Voltage in 0.1 volts" ::= { ipduDeviceSlaveInletStatusEntry 7 } inletSlaveStatusCurrent2 OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Current in 0.001 Amp." ::= { ipduDeviceSlaveInletStatusEntry 8 } inletSlaveStatusFrequency2 OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Frequency in 0.1 Hz" ::= { ipduDeviceSlaveInletStatusEntry 9 } inletSlaveStatusKwatt2 OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Kwatt in 0.001 KW/H" ::= { ipduDeviceSlaveInletStatusEntry 10 } inletSlaveStatusWH2 OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Kwatt in 0.001 KW/H" ::= { ipduDeviceSlaveInletStatusEntry 11 } ipduSlaveInletConfig OBJECT IDENTIFIER ::= { ipduSlaveInlet 2 } -- =========================================================================== -- -- ipduSlaveAllDevice -- -- Daisy Chain Device Group -- -- =========================================================================== ipduDeviceslaveInletConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduDeviceslaveInletConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of inlet on this device." ::= { ipduSlaveInletConfig 1} ipduDeviceslaveInletConfigEntry OBJECT-TYPE SYNTAX IpduDeviceslaveInletConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The inlet number of device." INDEX { slaveInletConfigIndex} ::= { ipduDeviceslaveInletConfigTable 1 } IpduDeviceslaveInletConfigEntry ::= SEQUENCE { slaveInletConfigIndex INTEGER, slaveInletConfigVoltageHigh INTEGER, slaveInletConfigVoltageLow INTEGER, slaveInlet2ConfigVoltageHigh INTEGER, slaveInlet2ConfigVoltageLow INTEGER } slaveInletConfigIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access inlet configuration table." ::= { ipduDeviceslaveInletConfigEntry 1 } slaveInletConfigVoltageHigh OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet high voltage threshold, in volts." ::= { ipduDeviceslaveInletConfigEntry 2 } slaveInletConfigVoltageLow OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet low voltage threshold, in volts." ::= { ipduDeviceslaveInletConfigEntry 3 } slaveInlet2ConfigVoltageHigh OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet 2 high voltage threshold, in volts." ::= { ipduDeviceslaveInletConfigEntry 4 } slaveInlet2ConfigVoltageLow OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet low voltage threshold, in volts." ::= { ipduDeviceslaveInletConfigEntry 5 } ipduSlaveOutlet OBJECT IDENTIFIER ::= { ipduSlave 3 } -- =========================================================================== -- -- ipduSlaveAllDevice -- -- Daisy Chain Device Group -- -- =========================================================================== ipduSlaveOutletConfig OBJECT IDENTIFIER ::= { ipduSlaveOutlet 1 } -- =========================================================================== -- -- ipduOutletConfig -- -- Outlet Config Group -- -- =========================================================================== -- -- Outlet Name Description -- ipduSlaveDeviceOutletNameTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduSlaveDeviceOutletNameEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipduSlaveOutletConfig 1} ipduSlaveDeviceOutletNameEntry OBJECT-TYPE SYNTAX IpduSlaveDeviceOutletNameEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletNameIndex} ::= { ipduSlaveDeviceOutletNameTable 1 } IpduSlaveDeviceOutletNameEntry ::= SEQUENCE { slaveOutletNameIndex INTEGER, slaveOutletName01 DisplayString, slaveOutletName02 DisplayString, slaveOutletName03 DisplayString, slaveOutletName04 DisplayString, slaveOutletName05 DisplayString, slaveOutletName06 DisplayString, slaveOutletName07 DisplayString, slaveOutletName08 DisplayString, slaveOutletName09 DisplayString, slaveOutletName10 DisplayString, slaveOutletName11 DisplayString, slaveOutletName12 DisplayString } slaveOutletNameIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipduSlaveDeviceOutletNameEntry 1 } slaveOutletName01 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletNameEntry 2 } slaveOutletName02 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletNameEntry 3 } slaveOutletName03 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletNameEntry 4 } slaveOutletName04 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletNameEntry 5 } slaveOutletName05 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletNameEntry 6 } slaveOutletName06 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletNameEntry 7 } slaveOutletName07 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletNameEntry 8 } slaveOutletName08 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletNameEntry 9 } slaveOutletName09 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletNameEntry 10 } slaveOutletName10 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletNameEntry 11 } slaveOutletName11 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletNameEntry 12 } slaveOutletName12 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletNameEntry 13 } -- =============================== -- Outlet Location Description -- =============================== ipduSlaveDeviceOutletLocationTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduSlaveDeviceOutletLocationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipduSlaveOutletConfig 2} ipduSlaveDeviceOutletLocationEntry OBJECT-TYPE SYNTAX IpduSlaveDeviceOutletLocationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletLocationIndex} ::= { ipduSlaveDeviceOutletLocationTable 1 } IpduSlaveDeviceOutletLocationEntry ::= SEQUENCE { slaveOutletLocationIndex INTEGER, slaveOutletLocation01 DisplayString, slaveOutletLocation02 DisplayString, slaveOutletLocation03 DisplayString, slaveOutletLocation04 DisplayString, slaveOutletLocation05 DisplayString, slaveOutletLocation06 DisplayString, slaveOutletLocation07 DisplayString, slaveOutletLocation08 DisplayString, slaveOutletLocation09 DisplayString, slaveOutletLocation10 DisplayString, slaveOutletLocation11 DisplayString, slaveOutletLocation12 DisplayString } slaveOutletLocationIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipduSlaveDeviceOutletLocationEntry 1 } slaveOutletLocation01 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletLocationEntry 2 } slaveOutletLocation02 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletLocationEntry 3 } slaveOutletLocation03 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletLocationEntry 4 } slaveOutletLocation04 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletLocationEntry 5 } slaveOutletLocation05 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletLocationEntry 6 } slaveOutletLocation06 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletLocationEntry 7 } slaveOutletLocation07 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletLocationEntry 8 } slaveOutletLocation08 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletLocationEntry 9 } slaveOutletLocation09 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletLocationEntry 10 } slaveOutletLocation10 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletLocationEntry 11 } slaveOutletLocation11 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletLocationEntry 12 } slaveOutletLocation12 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipduSlaveDeviceOutletLocationEntry 13 } -- ========================================== -- Outlet On Delay Time -- ========================================== ipduSlaveDeviceOutletOnTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduSlaveDeviceOutletOnTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipduSlaveOutletConfig 3} ipduSlaveDeviceOutletOnTimeEntry OBJECT-TYPE SYNTAX IpduSlaveDeviceOutletOnTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletOnTimeIndex} ::= { ipduSlaveDeviceOutletOnTimeTable 1 } IpduSlaveDeviceOutletOnTimeEntry ::= SEQUENCE { slaveOutletOnTimeIndex INTEGER, slaveOutletOnTime01 INTEGER, slaveOutletOnTime02 INTEGER, slaveOutletOnTime03 INTEGER, slaveOutletOnTime04 INTEGER, slaveOutletOnTime05 INTEGER, slaveOutletOnTime06 INTEGER, slaveOutletOnTime07 INTEGER, slaveOutletOnTime08 INTEGER, slaveOutletOnTime09 INTEGER, slaveOutletOnTime10 INTEGER, slaveOutletOnTime11 INTEGER, slaveOutletOnTime12 INTEGER } slaveOutletOnTimeIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipduSlaveDeviceOutletOnTimeEntry 1 } slaveOutletOnTime01 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOnTimeEntry 2 } slaveOutletOnTime02 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOnTimeEntry 3 } slaveOutletOnTime03 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOnTimeEntry 4 } slaveOutletOnTime04 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOnTimeEntry 5 } slaveOutletOnTime05 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOnTimeEntry 6 } slaveOutletOnTime06 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOnTimeEntry 7 } slaveOutletOnTime07 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOnTimeEntry 8 } slaveOutletOnTime08 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOnTimeEntry 9 } slaveOutletOnTime09 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOnTimeEntry 10 } slaveOutletOnTime10 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOnTimeEntry 11 } slaveOutletOnTime11 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOnTimeEntry 12 } slaveOutletOnTime12 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOnTimeEntry 13 } -- ========================================== -- Outlet Off Delay Time -- ========================================== ipduSlaveDeviceOutletOffTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduSlaveDeviceOutletOffTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipduSlaveOutletConfig 4} ipduSlaveDeviceOutletOffTimeEntry OBJECT-TYPE SYNTAX IpduSlaveDeviceOutletOffTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletOffTimeIndex} ::= { ipduSlaveDeviceOutletOffTimeTable 1 } IpduSlaveDeviceOutletOffTimeEntry ::= SEQUENCE { slaveOutletOffTimeIndex INTEGER, slaveOutletOffTime01 INTEGER, slaveOutletOffTime02 INTEGER, slaveOutletOffTime03 INTEGER, slaveOutletOffTime04 INTEGER, slaveOutletOffTime05 INTEGER, slaveOutletOffTime06 INTEGER, slaveOutletOffTime07 INTEGER, slaveOutletOffTime08 INTEGER, slaveOutletOffTime09 INTEGER, slaveOutletOffTime10 INTEGER, slaveOutletOffTime11 INTEGER, slaveOutletOffTime12 INTEGER } slaveOutletOffTimeIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipduSlaveDeviceOutletOffTimeEntry 1 } slaveOutletOffTime01 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOffTimeEntry 2 } slaveOutletOffTime02 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOffTimeEntry 3 } slaveOutletOffTime03 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOffTimeEntry 4 } slaveOutletOffTime04 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOffTimeEntry 5 } slaveOutletOffTime05 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOffTimeEntry 6 } slaveOutletOffTime06 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOffTimeEntry 7 } slaveOutletOffTime07 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOffTimeEntry 8 } slaveOutletOffTime08 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOffTimeEntry 9 } slaveOutletOffTime09 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOffTimeEntry 10 } slaveOutletOffTime10 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOffTimeEntry 11 } slaveOutletOffTime11 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOffTimeEntry 12 } slaveOutletOffTime12 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipduSlaveDeviceOutletOffTimeEntry 13 } -- ========================================== -- Outlet Current TH -- ========================================== ipduSlaveDeviceOutletCurrThTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduSlaveDeviceOutletCurrThEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipduSlaveOutletConfig 5} ipduSlaveDeviceOutletCurrThEntry OBJECT-TYPE SYNTAX IpduSlaveDeviceOutletCurrThEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletCurrThIndex} ::= { ipduSlaveDeviceOutletCurrThTable 1 } IpduSlaveDeviceOutletCurrThEntry ::= SEQUENCE { slaveOutletCurrThIndex INTEGER, slaveOutletCurrTh01 INTEGER, slaveOutletCurrTh02 INTEGER, slaveOutletCurrTh03 INTEGER, slaveOutletCurrTh04 INTEGER, slaveOutletCurrTh05 INTEGER, slaveOutletCurrTh06 INTEGER, slaveOutletCurrTh07 INTEGER, slaveOutletCurrTh08 INTEGER, slaveOutletCurrTh09 INTEGER, slaveOutletCurrTh10 INTEGER, slaveOutletCurrTh11 INTEGER, slaveOutletCurrTh12 INTEGER } slaveOutletCurrThIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipduSlaveDeviceOutletCurrThEntry 1 } slaveOutletCurrTh01 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipduSlaveDeviceOutletCurrThEntry 2 } slaveOutletCurrTh02 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipduSlaveDeviceOutletCurrThEntry 3 } slaveOutletCurrTh03 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipduSlaveDeviceOutletCurrThEntry 4 } slaveOutletCurrTh04 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipduSlaveDeviceOutletCurrThEntry 5 } slaveOutletCurrTh05 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipduSlaveDeviceOutletCurrThEntry 6 } slaveOutletCurrTh06 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipduSlaveDeviceOutletCurrThEntry 7 } slaveOutletCurrTh07 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipduSlaveDeviceOutletCurrThEntry 8 } slaveOutletCurrTh08 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipduSlaveDeviceOutletCurrThEntry 9 } slaveOutletCurrTh09 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipduSlaveDeviceOutletCurrThEntry 10 } slaveOutletCurrTh10 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipduSlaveDeviceOutletCurrThEntry 11 } slaveOutletCurrTh11 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipduSlaveDeviceOutletCurrThEntry 12 } slaveOutletCurrTh12 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipduSlaveDeviceOutletCurrThEntry 13 } ipduSlaveOutletStatus OBJECT IDENTIFIER ::= { ipduSlaveOutlet 2 } -- =========================================================================== -- -- ipduOutletStatus -- -- Outlet Status Group -- -- =========================================================================== -- ========================================== -- Outlet Current -- ========================================== ipduSlaveDeviceOutletCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduSlaveDeviceOutletCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipduSlaveOutletStatus 1} ipduSlaveDeviceOutletCurrentEntry OBJECT-TYPE SYNTAX IpduSlaveDeviceOutletCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletCurrentIndex} ::= { ipduSlaveDeviceOutletCurrentTable 1 } IpduSlaveDeviceOutletCurrentEntry ::= SEQUENCE { slaveOutletCurrentIndex INTEGER, slaveOutletCurrent01 INTEGER, slaveOutletCurrent02 INTEGER, slaveOutletCurrent03 INTEGER, slaveOutletCurrent04 INTEGER, slaveOutletCurrent05 INTEGER, slaveOutletCurrent06 INTEGER, slaveOutletCurrent07 INTEGER, slaveOutletCurrent08 INTEGER, slaveOutletCurrent09 INTEGER, slaveOutletCurrent10 INTEGER, slaveOutletCurrent11 INTEGER, slaveOutletCurrent12 INTEGER } slaveOutletCurrentIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipduSlaveDeviceOutletCurrentEntry 1 } slaveOutletCurrent01 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet A Current in 0.001 Amp." ::= { ipduSlaveDeviceOutletCurrentEntry 2 } slaveOutletCurrent02 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet B Current in 0.001 Amp." ::= { ipduSlaveDeviceOutletCurrentEntry 3 } slaveOutletCurrent03 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet C Current in 0.001 Amp." ::= { ipduSlaveDeviceOutletCurrentEntry 4 } slaveOutletCurrent04 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet D Current in 0.001 Amp." ::= { ipduSlaveDeviceOutletCurrentEntry 5 } slaveOutletCurrent05 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet E Current in 0.001 Amp." ::= { ipduSlaveDeviceOutletCurrentEntry 6 } slaveOutletCurrent06 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet F Current in 0.001 Amp." ::= { ipduSlaveDeviceOutletCurrentEntry 7 } slaveOutletCurrent07 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet G Current in 0.001 Amp." ::= { ipduSlaveDeviceOutletCurrentEntry 8 } slaveOutletCurrent08 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet H Current in 0.001 Amp." ::= { ipduSlaveDeviceOutletCurrentEntry 9 } slaveOutletCurrent09 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet I Current in 0.001 Amp." ::= { ipduSlaveDeviceOutletCurrentEntry 10 } slaveOutletCurrent10 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet J Current in 0.001 Amp." ::= { ipduSlaveDeviceOutletCurrentEntry 11 } slaveOutletCurrent11 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet K Current in 0.001 Amp." ::= { ipduSlaveDeviceOutletCurrentEntry 12 } slaveOutletCurrent12 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet L Current in 0.001 Amp." ::= { ipduSlaveDeviceOutletCurrentEntry 13 } -- ========================================== -- Outlet W/H -- ========================================== ipduSlaveDeviceOutletWattTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduSlaveDeviceOutletWattEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipduSlaveOutletStatus 2} ipduSlaveDeviceOutletWattEntry OBJECT-TYPE SYNTAX IpduSlaveDeviceOutletWattEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletWattIndex} ::= { ipduSlaveDeviceOutletWattTable 1 } IpduSlaveDeviceOutletWattEntry ::= SEQUENCE { slaveOutletWattIndex INTEGER, slaveOutletWatt01 INTEGER, slaveOutletWatt02 INTEGER, slaveOutletWatt03 INTEGER, slaveOutletWatt04 INTEGER, slaveOutletWatt05 INTEGER, slaveOutletWatt06 INTEGER, slaveOutletWatt07 INTEGER, slaveOutletWatt08 INTEGER, slaveOutletWatt09 INTEGER, slaveOutletWatt10 INTEGER, slaveOutletWatt11 INTEGER, slaveOutletWatt12 INTEGER } slaveOutletWattIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipduSlaveDeviceOutletWattEntry 1 } slaveOutletWatt01 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet A Watt in 0.1 W/H." ::= { ipduSlaveDeviceOutletWattEntry 2 } slaveOutletWatt02 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet B Watt in 0.1 W/H." ::= { ipduSlaveDeviceOutletWattEntry 3 } slaveOutletWatt03 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet C Watt in 0.1 W/H." ::= { ipduSlaveDeviceOutletWattEntry 4 } slaveOutletWatt04 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet D Watt in 0.1 W/H." ::= { ipduSlaveDeviceOutletWattEntry 5 } slaveOutletWatt05 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet E Watt in 0.1 W/H." ::= { ipduSlaveDeviceOutletWattEntry 6 } slaveOutletWatt06 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet F Watt in 0.1 W/H." ::= { ipduSlaveDeviceOutletWattEntry 7 } slaveOutletWatt07 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet G Watt in 0.1 W/H." ::= { ipduSlaveDeviceOutletWattEntry 8 } slaveOutletWatt08 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet H Watt in 0.1 W/H." ::= { ipduSlaveDeviceOutletWattEntry 9 } slaveOutletWatt09 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet I Watt in 0.1 W/H." ::= { ipduSlaveDeviceOutletWattEntry 10 } slaveOutletWatt10 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet J Watt in 0.1 W/H." ::= { ipduSlaveDeviceOutletWattEntry 11 } slaveOutletWatt11 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet K Watt in 0.1 W/H." ::= { ipduSlaveDeviceOutletWattEntry 12 } slaveOutletWatt12 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet L Watt in 0.1 W/H." ::= { ipduSlaveDeviceOutletWattEntry 13 } -- ========================================== -- Outlet W/H -- ========================================== ipduSlaveDeviceOutletKwattTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduSlaveDeviceOutletKwattEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipduSlaveOutletStatus 3} ipduSlaveDeviceOutletKwattEntry OBJECT-TYPE SYNTAX IpduSlaveDeviceOutletKwattEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletKwattIndex} ::= { ipduSlaveDeviceOutletKwattTable 1 } IpduSlaveDeviceOutletKwattEntry ::= SEQUENCE { slaveOutletKwattIndex INTEGER, slaveOutletKwatt01 INTEGER, slaveOutletKwatt02 INTEGER, slaveOutletKwatt03 INTEGER, slaveOutletKwatt04 INTEGER, slaveOutletKwatt05 INTEGER, slaveOutletKwatt06 INTEGER, slaveOutletKwatt07 INTEGER, slaveOutletKwatt08 INTEGER, slaveOutletKwatt09 INTEGER, slaveOutletKwatt10 INTEGER, slaveOutletKwatt11 INTEGER, slaveOutletKwatt12 INTEGER } slaveOutletKwattIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipduSlaveDeviceOutletKwattEntry 1 } slaveOutletKwatt01 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet A Kwatt in 0.001 KW/H." ::= { ipduSlaveDeviceOutletKwattEntry 2 } slaveOutletKwatt02 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet B Kwatt in 0.001 KW/H." ::= { ipduSlaveDeviceOutletKwattEntry 3 } slaveOutletKwatt03 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet C Kwatt in 0.001 KW/H." ::= { ipduSlaveDeviceOutletKwattEntry 4 } slaveOutletKwatt04 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet D Kwatt in 0.001 KW/H." ::= { ipduSlaveDeviceOutletKwattEntry 5 } slaveOutletKwatt05 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet E Kwatt in 0.001 KW/H." ::= { ipduSlaveDeviceOutletKwattEntry 6 } slaveOutletKwatt06 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet F Kwatt in 0.001 KW/H." ::= { ipduSlaveDeviceOutletKwattEntry 7 } slaveOutletKwatt07 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet G Kwatt in 0.001 KW/H." ::= { ipduSlaveDeviceOutletKwattEntry 8 } slaveOutletKwatt08 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet H Kwatt in 0.001 KW/H." ::= { ipduSlaveDeviceOutletKwattEntry 9 } slaveOutletKwatt09 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet I Kwatt in 0.001 KW/H." ::= { ipduSlaveDeviceOutletKwattEntry 10 } slaveOutletKwatt10 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet J Kwatt in 0.001 KW/H." ::= { ipduSlaveDeviceOutletKwattEntry 11 } slaveOutletKwatt11 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet K Kwatt in 0.001 KW/H." ::= { ipduSlaveDeviceOutletKwattEntry 12 } slaveOutletKwatt12 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet L Kwatt in 0.001 KW/H." ::= { ipduSlaveDeviceOutletKwattEntry 13 } ipduSlaveOutletAction OBJECT IDENTIFIER ::= { ipduSlaveOutlet 3 } -- =========================================================================== -- -- ipduOutletStatus -- -- Outlet Action Group -- -- =========================================================================== ipduSlaveDeviceOutletActionTable OBJECT-TYPE SYNTAX SEQUENCE OF IpduSlaveDeviceOutletActionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipduSlaveOutletAction 1} ipduSlaveDeviceOutletActionEntry OBJECT-TYPE SYNTAX IpduSlaveDeviceOutletActionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletActionIndex} ::= { ipduSlaveDeviceOutletActionTable 1 } IpduSlaveDeviceOutletActionEntry ::= SEQUENCE { slaveOutletActionIndex INTEGER, slaveOutletAction01 INTEGER, slaveOutletAction02 INTEGER, slaveOutletAction03 INTEGER, slaveOutletAction04 INTEGER, slaveOutletAction05 INTEGER, slaveOutletAction06 INTEGER, slaveOutletAction07 INTEGER, slaveOutletAction08 INTEGER, slaveOutletAction09 INTEGER, slaveOutletAction10 INTEGER, slaveOutletAction11 INTEGER, slaveOutletAction12 INTEGER } slaveOutletActionIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipduSlaveDeviceOutletActionEntry 1 } slaveOutletAction01 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipduSlaveDeviceOutletActionEntry 2 } slaveOutletAction02 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipduSlaveDeviceOutletActionEntry 3 } slaveOutletAction03 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipduSlaveDeviceOutletActionEntry 4 } slaveOutletAction04 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipduSlaveDeviceOutletActionEntry 5 } slaveOutletAction05 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipduSlaveDeviceOutletActionEntry 6 } slaveOutletAction06 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipduSlaveDeviceOutletActionEntry 7 } slaveOutletAction07 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipduSlaveDeviceOutletActionEntry 8 } slaveOutletAction08 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipduSlaveDeviceOutletActionEntry 9 } slaveOutletAction09 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipduSlaveDeviceOutletActionEntry 10 } slaveOutletAction10 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipduSlaveDeviceOutletActionEntry 11 } slaveOutletAction11 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipduSlaveDeviceOutletActionEntry 12 } slaveOutletAction12 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipduSlaveDeviceOutletActionEntry 13 } ipduEnvEmd OBJECT IDENTIFIER ::= { ipduEnv 1 } -- =========================================================================== -- -- ipduEnvEmd -- -- Environmental Monitor Device Group -- -- =========================================================================== ipduEnvEmdStatus OBJECT IDENTIFIER ::= { ipduEnvEmd 1 } -- =========================================================================== -- -- ipduEnvEmd -- -- Environmental Monitor Device Status Group -- -- =========================================================================== ipduEnvEmdStatusEmdType OBJECT-TYPE SYNTAX INTEGER { unknown(1), disabled(2), eMD-HT(3), eMD-T(4) } ACCESS read-only STATUS mandatory DESCRIPTION "EMD Type." ::= { ipduEnvEmdStatus 1 } ipduEnvEmdStatusTemperature OBJECT-TYPE SYNTAX INTEGER (1..10000) -- ACCESS read-only STATUS mandatory DESCRIPTION "EMD Temperature in 0.1 degree C." ::= { ipduEnvEmdStatus 2 } ipduEnvEmdStatusHumidity OBJECT-TYPE SYNTAX INTEGER (1..10000) -- ACCESS read-only STATUS mandatory DESCRIPTION "EMD Humidity in 0.1%." ::= { ipduEnvEmdStatus 3 } ipduEnvEmdStatusAlarm1 OBJECT-TYPE SYNTAX INTEGER { unknown(1), disabled(2), alarm(3), normal(4) } ACCESS read-only STATUS mandatory DESCRIPTION "EMD Alarm-1 state." ::= { ipduEnvEmdStatus 4 } ipduEnvEmdStatusAlarm2 OBJECT-TYPE SYNTAX INTEGER { unknown(1), disabled(2), alarm(3), normal(4) } ACCESS read-only STATUS mandatory DESCRIPTION "EMD Alarm-2 state." ::= { ipduEnvEmdStatus 5 } ipduEnvEmdConfig OBJECT IDENTIFIER ::= { ipduEnvEmd 2 } -- =========================================================================== -- -- ipduEnvEmd -- -- Environmental Monitor Device Configuration Group -- -- =========================================================================== ipduEnvEmdConfigEmdPresence OBJECT-TYPE SYNTAX INTEGER { disabled(1), autoDetect(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Configure the EMD presence by auto-detect or not exist (disabled)." ::= { ipduEnvEmdConfig 1 } ipduEnvEmdConfigEmdName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of Emd." ::= { ipduEnvEmdConfig 2 } ipduEnvEmdConfigTemp OBJECT IDENTIFIER ::= { ipduEnvEmdConfig 3 } -- =========================================================================== -- -- ipduEnvEmdConfigTemp -- -- Environmental Monitor Device Temperature Configuration Group -- -- =========================================================================== ipduEnvEmdConfigTempName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of EMD Temperature sensor." ::= { ipduEnvEmdConfigTemp 1 } ipduEnvEmdConfigTempHighSetPoint OBJECT-TYPE SYNTAX INTEGER (5..65) -- ACCESS read-write STATUS mandatory DESCRIPTION "EMD Temperature set point high, alarm will active when temperature over this value, in degree C." ::= { ipduEnvEmdConfigTemp 2 } ipduEnvEmdConfigTempHighStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enabled/disabled the high setpoint be applied or not" ::= { ipduEnvEmdConfigTemp 3 } ipduEnvEmdConfigTempLowSetPoint OBJECT-TYPE SYNTAX INTEGER (5..65) -- ACCESS read-write STATUS mandatory DESCRIPTION "EMD Temperature set point high, alarm will active when temperature under this value, in degree C." ::= { ipduEnvEmdConfigTemp 4 } ipduEnvEmdConfigTempLowStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enabled/disabled the low setpoint be applied or not" ::= { ipduEnvEmdConfigTemp 5 } ipduEnvEmdConfigTempOffset OBJECT-TYPE SYNTAX INTEGER { t0p0(1), t0p5(2), t1p0(3), t1p5(4), t2p0(5), t2p5(6), t3p0(7), t-0p5(8), t-1p0(9), t-1p5(10), t-2p0(11), t-2p5(12), t-3p0(13) } ACCESS read-write STATUS mandatory DESCRIPTION "Offset of temperature in degree C to adjust EMD temperature measurement." ::= { ipduEnvEmdConfigTemp 6 } ipduEnvEmdConfigHumi OBJECT IDENTIFIER ::= { ipduEnvEmdConfig 4 } -- =========================================================================== -- -- ipduEnvEmdConfigHumi -- -- Environmental Monitor Device Humidity Configuration Group -- -- =========================================================================== ipduEnvEmdConfigHumiName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of EMD Humidity." ::= { ipduEnvEmdConfigHumi 1 } ipduEnvEmdConfigHumiHighSetPoint OBJECT-TYPE SYNTAX INTEGER (5..95) -- ACCESS read-write STATUS mandatory DESCRIPTION "EMD humidity set point high, alarm will active when humidity over this value, in %." ::= { ipduEnvEmdConfigHumi 2 } ipduEnvEmdConfigHumiHighStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enabled/disabled the high setpoint be applied or not" ::= { ipduEnvEmdConfigHumi 3 } ipduEnvEmdConfigHumiLowSetPoint OBJECT-TYPE SYNTAX INTEGER (5..95) -- ACCESS read-write STATUS mandatory DESCRIPTION "EMD humidity set point low, alarm will active when humidity under this value, in %." ::= { ipduEnvEmdConfigHumi 4 } ipduEnvEmdConfigHumiLowStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enabled/disabled the high setpoint be applied or not" ::= { ipduEnvEmdConfigHumi 5 } ipduEnvEmdConfigHumiOffset OBJECT-TYPE SYNTAX INTEGER { h0p0(1), h1p0(2), h2p0(3), h3p0(4), h4p0(5), h5p0(6), h6p0(7), h-1p0(8), h-2p0(9), h-3p0(10), h-4p0(11), h-5p0(12), h-6p0(13) } ACCESS read-write STATUS mandatory DESCRIPTION "Emd Hum Offset;" ::= { ipduEnvEmdConfigHumi 6 } ipduEnvEmdConfigAlarm1 OBJECT IDENTIFIER ::= { ipduEnvEmdConfig 5 } -- =========================================================================== -- -- ipduEnvEmdConfigAlarm1 -- -- Environmental Monitor Device Alarm-1 Configuration Group -- -- =========================================================================== ipduEnvEmdConfigAlarm1Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of EMD Alarm-1." ::= { ipduEnvEmdConfigAlarm1 1 } ipduEnvEmdConfigAlarm1Type OBJECT-TYPE SYNTAX INTEGER { disabled(1), normalOpen(2), normalClose(3) } ACCESS read-write STATUS mandatory DESCRIPTION "EMD Alarm-1 type" ::= { ipduEnvEmdConfigAlarm1 2 } ipduEnvEmdConfigAlarm2 OBJECT IDENTIFIER ::= { ipduEnvEmdConfig 6 } -- =========================================================================== -- -- ipduEnvEmdConfigAlarm2 -- -- Environmental Monitor Device Alarm-2 Configuration Group -- -- =========================================================================== ipduEnvEmdConfigAlarm2Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of EMD Alarm-2." ::= { ipduEnvEmdConfigAlarm2 1 } ipduEnvEmdConfigAlarm2Type OBJECT-TYPE SYNTAX INTEGER { disabled(1), normalOpen(2), normalClose(3) } ACCESS read-write STATUS mandatory DESCRIPTION "EMD Alarm-2 type" ::= { ipduEnvEmdConfigAlarm2 2 } -- =========================================================================== -- ipduTraps -- -- iPDU Trap group -- =========================================================================== -- This section defines the well-known notifications sent by -- iPDU agents. ipduInletVoltageTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusVoltage, inletConfigVoltageHigh, inletConfigDesc } DESCRIPTION "CRITICAL: The input voltage over high threshold." ::= 1 ipduInletVoltageNotTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusVoltage, inletConfigVoltageHigh, inletConfigDesc } DESCRIPTION "WARNING: The input voltage return from over high threshold." ::= 2 ipduInletVoltageTooLow TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusVoltage, inletConfigVoltageLow, inletConfigDesc } DESCRIPTION "CRITICAL: The input voltage under low threshold." ::= 3 ipduInletVoltageNotTooLow TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusVoltage, inletConfigVoltageLow, inletConfigDesc } DESCRIPTION "WARNING: The input voltage return from under low threshold." ::= 4 ipduInletCurrentTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusCurrent, inletConfigCurrentHigh, inletConfigDesc } DESCRIPTION "CRITICAL: The input current over high threshold." ::= 5 ipduInletCurrentNotTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusCurrent, inletConfigCurrentHigh, inletConfigDesc } DESCRIPTION "WARNING: The input current return from over high threshold." ::= 6 ipduInletFrequencyTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusFrequency, inletConfigFrequencyHigh, inletConfigDesc } DESCRIPTION "CRITICAL: The input frequency over high threshold." ::= 7 ipduInletFrequencyNotTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusFrequency, inletConfigFrequencyHigh, inletConfigDesc } DESCRIPTION "WARNING: The input frequency return from over high threshold." ::= 8 ipduInletFrequencyTooLow TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusFrequency, inletConfigFrequencyLow, inletConfigDesc } DESCRIPTION "CRITICAL: The input frequency under low threshold." ::= 9 ipduInletFrequencyNotTooLow TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusFrequency, inletConfigFrequencyLow, inletConfigDesc } DESCRIPTION "WARNING: The input frequency return from under low threshold." ::= 10 ipduInlet2VoltageTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusVoltage, inletConfigVoltageHigh, inletConfigDesc } DESCRIPTION "CRITICAL: The input2 voltage over high threshold." ::= 11 ipduInlet2VoltageNotTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusVoltage, inletConfigVoltageHigh, inletConfigDesc } DESCRIPTION "WARNING: The input2 voltage return from over high threshold." ::= 12 ipduInlet2VoltageTooLow TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusVoltage, inletConfigVoltageLow, inletConfigDesc } DESCRIPTION "CRITICAL: The input2 voltage under low threshold." ::= 13 ipduInlet2VoltageNotTooLow TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusVoltage, inletConfigVoltageLow, inletConfigDesc } DESCRIPTION "WARNING: The input2 voltage return from under low threshold." ::= 14 ipduInlet2CurrentTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusCurrent, inletConfigCurrentHigh, inletConfigDesc } DESCRIPTION "CRITICAL: The input2 current over high threshold." ::= 15 ipduInlet2CurrentNotTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusCurrent, inletConfigCurrentHigh, inletConfigDesc } DESCRIPTION "WARNING: The input2 current return from over high threshold." ::= 16 ipduInlet2FrequencyTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusFrequency, inletConfigFrequencyHigh, inletConfigDesc } DESCRIPTION "CRITICAL: The input2 frequency over high threshold." ::= 17 ipduInlet2FrequencyNotTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusFrequency, inletConfigFrequencyHigh, inletConfigDesc } DESCRIPTION "WARNING: The input2 frequency return from over high threshold." ::= 18 ipduInlet2FrequencyTooLow TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusFrequency, inletConfigFrequencyLow, inletConfigDesc } DESCRIPTION "CRITICAL: The input2 frequency under low threshold." ::= 19 ipduInlet2FrequencyNotTooLow TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { inletConfigIndex, inletStatusFrequency, inletConfigFrequencyLow, inletConfigDesc } DESCRIPTION "WARNING: The input2 frequency return from under low threshold." ::= 20 ipduOutletCurrentTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { outletConfigIndex, outletStatusCurrent, outletConfigCurrentHigh, outletConfigDesc } DESCRIPTION "CRITICAL: The output current of outlet over high threshold." ::= 21 ipduOutletCurrentNotTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { outletConfigIndex, outletStatusCurrent, outletConfigCurrentHigh, outletConfigDesc } DESCRIPTION "WARNING: The output current of outlet return from over high threshold." ::= 22 ipduOutletStateChanged TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { outletConfigIndex, outletStatusStatus, outletConfigDesc } DESCRIPTION "INFORMATION: The outlet state had changed from on to off, or from off to on." ::= 23 ipduEmdTemperatureNotHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { ipduEnvEmdStatusTemperature, ipduEnvEmdConfigTempHighSetPoint, ipduEnvEmdConfigTempName } DESCRIPTION "INFORMATION: emd Temperature Not High." ::= 24 ipduEmdTemperatureTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { ipduEnvEmdStatusTemperature, ipduEnvEmdConfigTempHighSetPoint, ipduEnvEmdConfigTempName } DESCRIPTION "WARNING: emd Temperature Too High." ::= 25 ipduEmdTemperatureNotLow TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { ipduEnvEmdStatusTemperature, ipduEnvEmdConfigTempLowSetPoint, ipduEnvEmdConfigTempName } DESCRIPTION "INFORMATION: emd Temperature Not Low." ::= 26 ipduEmdTemperatureTooLow TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { ipduEnvEmdStatusTemperature, ipduEnvEmdConfigTempLowSetPoint, ipduEnvEmdConfigTempName } DESCRIPTION "WARNING: emd Temperature Too Low." ::= 27 ipduEmdHumidityNotHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { ipduEnvEmdStatusHumidity, ipduEnvEmdConfigHumiHighSetPoint, ipduEnvEmdConfigHumiName } DESCRIPTION "INFORMATION: emd Humidity Not High." ::= 28 ipduEmdHumidityTooHigh TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { ipduEnvEmdStatusHumidity, ipduEnvEmdConfigHumiHighSetPoint, ipduEnvEmdConfigHumiName } DESCRIPTION "WARNING: emd Humidity Too High." ::= 29 ipduEmdHumidityNotLow TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { ipduEnvEmdStatusHumidity, ipduEnvEmdConfigHumiLowSetPoint, ipduEnvEmdConfigHumiName } DESCRIPTION "INFORMATION: emd Humidity Not Low." ::= 30 ipduEmdHumidityTooLow TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { ipduEnvEmdStatusHumidity, ipduEnvEmdConfigHumiLowSetPoint, ipduEnvEmdConfigHumiName } DESCRIPTION "WARNING: emd Humidity Too Low." ::= 31 ipduEmdAlarm1Normal TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { ipduEnvEmdConfigAlarm1Type, ipduEnvEmdConfigAlarm1Name } DESCRIPTION "INFORMATION: emd Alarm1 Normal." ::= 32 ipduEmdAlarm1Active TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { ipduEnvEmdConfigAlarm1Type, ipduEnvEmdConfigAlarm1Name } DESCRIPTION "WARNING: emd Alarm1 Active." ::= 33 ipduEmdAlarm2Normal TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { ipduEnvEmdConfigAlarm2Type, ipduEnvEmdConfigAlarm2Name } DESCRIPTION "INFORMATION: emd Alarm2 Normal." ::= 34 ipduEmdAlarm2Active TRAP-TYPE ENTERPRISE ipduTraps VARIABLES { ipduEnvEmdConfigAlarm2Type, ipduEnvEmdConfigAlarm2Name } DESCRIPTION "WARNING: emd Alarm2 Active." ::= 35 --========================================================================== -- Slave01 trap --========================================================================== ipduSlave01Inlet01OverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 input01 voltage over high threshold." ::= 36 ipduSlave01Inlet01NotOverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 input01 voltage Not over high threshold." ::= 37 ipduSlave01Inlet02OverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 input02 voltage over high threshold." ::= 38 ipduSlave01Inlet02NotOverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 input02 voltage Not over high threshold." ::= 39 ipduSlave01Inlet01UnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 input01 voltage under low threshold." ::= 40 ipduSlave01Inlet01NotUnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 input01 voltage Not under low threshold." ::= 41 ipduSlave01Inlet02UnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 input02 voltage under low threshold." ::= 42 ipduSlave01Inlet02NotUnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 input02 voltage Not under low threshold." ::= 43 ipduSlave01Inlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 input01 current over high threshold." ::= 44 ipduSlave01Inlet01NotCurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 input01 current not over high threshold." ::= 45 ipduSlave01Inlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 input02 current over high threshold." ::= 46 ipduSlave01Inlet02NotCurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 input02 current not over high threshold." ::= 47 ipduSlave01EmdTemperatureTooHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 emd Temperature Too High." ::= 48 ipduSlave01EmdTemperatureNotHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave01 emd Temperature Not High." ::= 49 ipduSlave01EmdTemperatureTooLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 emd Temperature Too Low." ::= 50 ipduSlave01EmdTemperatureNotLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave01 emd Temperature Not Low." ::= 51 ipduSlave01EmdHumidityTooHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 emd Humidity Too High." ::= 52 ipduSlave01EmdHumidityNotHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave01 emd Humidity Not High." ::= 53 ipduSlave01EmdHumidityTooLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 emd Humidity Too Low." ::= 54 ipduSlave01EmdHumidityNotLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave01 emd Humidity Not Low." ::= 55 ipduSlave01EmdAlarm1Active TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 emd Alarm1 Active." ::= 56 ipduSlave01EmdAlarm1Normal TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave01 emd Alarm1 Normal." ::= 57 ipduSlave01EmdAlarm2Active TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 emd Alarm2 Active." ::= 58 ipduSlave01EmdAlarm2Normal TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave01 emd Alarm2 Normal." ::= 59 ipduSlave01Outlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 Outlet01 Current over threshold." ::= 60 ipduSlave01Outlet01CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 Outlet01 Current not over threshold." ::= 61 ipduSlave01Outlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 Outlet02 Current over threshold." ::= 62 ipduSlave01Outlet02CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 Outlet02 Current not over threshold." ::= 63 ipduSlave01Outlet03CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 Outlet03 Current over threshold." ::= 64 ipduSlave01Outlet03CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 Outlet03 Current not over threshold." ::= 65 ipduSlave01Outlet04CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 Outlet04 Current over threshold." ::= 66 ipduSlave01Outlet04CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 Outlet04 Current not over threshold." ::= 67 ipduSlave01Outlet05CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 Outlet05 Current over threshold." ::= 68 ipduSlave01Outlet05CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 Outlet05 Current not over threshold." ::= 69 ipduSlave01Outlet06CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 Outlet06 Current over threshold." ::= 70 ipduSlave01Outlet06CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 Outlet06 Current not over threshold." ::= 71 ipduSlave01Outlet07CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 Outlet07 Current over threshold." ::= 72 ipduSlave01Outlet07CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 Outlet07 Current not over threshold." ::= 73 ipduSlave01Outlet08CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 Outlet08 Current over threshold." ::= 74 ipduSlave01Outlet08CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 Outlet08 Current not over threshold." ::= 75 ipduSlave01Outlet09CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 Outlet09 Current over threshold." ::= 76 ipduSlave01Outlet09CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 Outlet09 Current not over threshold." ::= 77 ipduSlave01Outlet10CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 Outlet10 Current over threshold." ::= 78 ipduSlave01Outlet10CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 Outlet10 Current not over threshold." ::= 79 ipduSlave01Outlet11CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 Outlet11 Current over threshold." ::= 80 ipduSlave01Outlet11CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 Outlet11 Current not over threshold." ::= 81 ipduSlave01Outlet12CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave01 Outlet12 Current over threshold." ::= 82 ipduSlave01Outlet12CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave01 Outlet12 Current not over threshold." ::= 83 --========================================================================== -- Slave02 trap --========================================================================== ipduSlave02Inlet01OverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 input01 voltage over high threshold." ::= 84 ipduSlave02Inlet01NotOverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 input01 voltage Not over high threshold." ::= 85 ipduSlave02Inlet02OverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 input02 voltage over high threshold." ::= 86 ipduSlave02Inlet02NotOverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 input02 voltage Not over high threshold." ::= 87 ipduSlave02Inlet01UnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 input01 voltage under low threshold." ::= 88 ipduSlave02Inlet01NotUnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 input01 voltage Not under low threshold." ::= 89 ipduSlave02Inlet02UnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 input02 voltage under low threshold." ::= 90 ipduSlave02Inlet02NotUnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 input02 voltage Not under low threshold." ::= 91 ipduSlave02Inlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 input01 current over high threshold." ::= 92 ipduSlave02Inlet01NotCurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 input01 current not over high threshold." ::= 93 ipduSlave02Inlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 input02 current over high threshold." ::= 94 ipduSlave02Inlet02NotCurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 input02 current not over high threshold." ::= 95 ipduSlave02EmdTemperatureTooHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 emd Temperature Too High." ::= 96 ipduSlave02EmdTemperatureNotHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave02 emd Temperature Not High." ::= 97 ipduSlave02EmdTemperatureTooLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 emd Temperature Too Low." ::= 98 ipduSlave02EmdTemperatureNotLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave02 emd Temperature Not Low." ::= 99 ipduSlave02EmdHumidityTooHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 emd Humidity Too High." ::= 100 ipduSlave02EmdHumidityNotHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave02 emd Humidity Not High." ::= 101 ipduSlave02EmdHumidityTooLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 emd Humidity Too Low." ::= 102 ipduSlave02EmdHumidityNotLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave02 emd Humidity Not Low." ::= 103 ipduSlave02EmdAlarm1Active TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 emd Alarm1 Active." ::= 104 ipduSlave02EmdAlarm1Normal TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave02 emd Alarm1 Normal." ::= 105 ipduSlave02EmdAlarm2Active TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 emd Alarm2 Active." ::= 106 ipduSlave02EmdAlarm2Normal TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave02 emd Alarm2 Normal." ::= 107 ipduSlave02Outlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 Outlet01 Current over threshold." ::= 108 ipduSlave02Outlet01CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 Outlet01 Current not over threshold." ::= 109 ipduSlave02Outlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 Outlet02 Current over threshold." ::= 110 ipduSlave02Outlet02CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 Outlet02 Current not over threshold." ::= 111 ipduSlave02Outlet03CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 Outlet03 Current over threshold." ::= 112 ipduSlave02Outlet03CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 Outlet03 Current not over threshold." ::= 113 ipduSlave02Outlet04CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 Outlet04 Current over threshold." ::= 114 ipduSlave02Outlet04CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 Outlet04 Current not over threshold." ::= 115 ipduSlave02Outlet05CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 Outlet05 Current over threshold." ::= 116 ipduSlave02Outlet05CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 Outlet05 Current not over threshold." ::= 117 ipduSlave02Outlet06CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 Outlet06 Current over threshold." ::= 118 ipduSlave02Outlet06CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 Outlet06 Current not over threshold." ::= 119 ipduSlave02Outlet07CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 Outlet07 Current over threshold." ::= 120 ipduSlave02Outlet07CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 Outlet07 Current not over threshold." ::= 121 ipduSlave02Outlet08CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 Outlet08 Current over threshold." ::= 122 ipduSlave02Outlet08CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 Outlet08 Current not over threshold." ::= 123 ipduSlave02Outlet09CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 Outlet09 Current over threshold." ::= 124 ipduSlave02Outlet09CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 Outlet09 Current not over threshold." ::= 125 ipduSlave02Outlet10CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 Outlet10 Current over threshold." ::= 126 ipduSlave02Outlet10CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 Outlet10 Current not over threshold." ::= 127 ipduSlave02Outlet11CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 Outlet11 Current over threshold." ::= 128 ipduSlave02Outlet11CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 Outlet11 Current not over threshold." ::= 129 ipduSlave02Outlet12CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave02 Outlet12 Current over threshold." ::= 130 ipduSlave02Outlet12CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave02 Outlet12 Current not over threshold." ::= 131 --========================================================================== -- Slave03 trap --========================================================================== ipduSlave03Inlet01OverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 input01 voltage over high threshold." ::= 132 ipduSlave03Inlet01NotOverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 input01 voltage Not over high threshold." ::= 133 ipduSlave03Inlet02OverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 input02 voltage over high threshold." ::= 134 ipduSlave03Inlet02NotOverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 input02 voltage Not over high threshold." ::= 135 ipduSlave03Inlet01UnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 input01 voltage under low threshold." ::= 136 ipduSlave03Inlet01NotUnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 input01 voltage Not under low threshold." ::= 137 ipduSlave03Inlet02UnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 input02 voltage under low threshold." ::= 138 ipduSlave03Inlet02NotUnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 input02 voltage Not under low threshold." ::= 139 ipduSlave03Inlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 input01 current over high threshold." ::= 140 ipduSlave03Inlet01NotCurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 input01 current not over high threshold." ::= 141 ipduSlave03Inlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 input02 current over high threshold." ::= 142 ipduSlave03Inlet02NotCurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 input02 current not over high threshold." ::= 143 ipduSlave03EmdTemperatureTooHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 emd Temperature Too High." ::= 144 ipduSlave03EmdTemperatureNotHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave03 emd Temperature Not High." ::= 145 ipduSlave03EmdTemperatureTooLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 emd Temperature Too Low." ::= 146 ipduSlave03EmdTemperatureNotLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave03 emd Temperature Not Low." ::= 147 ipduSlave03EmdHumidityTooHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 emd Humidity Too High." ::= 148 ipduSlave03EmdHumidityNotHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave03 emd Humidity Not High." ::= 149 ipduSlave03EmdHumidityTooLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 emd Humidity Too Low." ::= 150 ipduSlave03EmdHumidityNotLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave03 emd Humidity Not Low." ::= 151 ipduSlave03EmdAlarm1Active TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 emd Alarm1 Active." ::= 152 ipduSlave03EmdAlarm1Normal TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave03 emd Alarm1 Normal." ::= 153 ipduSlave03EmdAlarm2Active TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 emd Alarm2 Active." ::= 154 ipduSlave03EmdAlarm2Normal TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave03 emd Alarm2 Normal." ::= 155 ipduSlave03Outlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 Outlet01 Current over threshold." ::= 156 ipduSlave03Outlet01CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 Outlet01 Current not over threshold." ::= 157 ipduSlave03Outlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 Outlet02 Current over threshold." ::= 158 ipduSlave03Outlet02CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 Outlet02 Current not over threshold." ::= 159 ipduSlave03Outlet03CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 Outlet03 Current over threshold." ::= 160 ipduSlave03Outlet03CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 Outlet03 Current not over threshold." ::= 161 ipduSlave03Outlet04CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 Outlet04 Current over threshold." ::= 162 ipduSlave03Outlet04CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 Outlet04 Current not over threshold." ::= 163 ipduSlave03Outlet05CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 Outlet05 Current over threshold." ::= 164 ipduSlave03Outlet05CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 Outlet05 Current not over threshold." ::= 165 ipduSlave03Outlet06CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 Outlet06 Current over threshold." ::= 166 ipduSlave03Outlet06CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 Outlet06 Current not over threshold." ::= 167 ipduSlave03Outlet07CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 Outlet07 Current over threshold." ::= 168 ipduSlave03Outlet07CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 Outlet07 Current not over threshold." ::= 169 ipduSlave03Outlet08CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 Outlet08 Current over threshold." ::= 170 ipduSlave03Outlet08CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 Outlet08 Current not over threshold." ::= 171 ipduSlave03Outlet09CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 Outlet09 Current over threshold." ::= 172 ipduSlave03Outlet09CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 Outlet09 Current not over threshold." ::= 173 ipduSlave03Outlet10CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 Outlet10 Current over threshold." ::= 174 ipduSlave03Outlet10CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 Outlet10 Current not over threshold." ::= 175 ipduSlave03Outlet11CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 Outlet11 Current over threshold." ::= 176 ipduSlave03Outlet11CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 Outlet11 Current not over threshold." ::= 177 ipduSlave03Outlet12CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave03 Outlet12 Current over threshold." ::= 178 ipduSlave03Outlet12CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave03 Outlet12 Current not over threshold." ::= 179 --========================================================================== -- Slave04 trap --========================================================================== ipduSlave04Inlet01OverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 input01 voltage over high threshold." ::= 180 ipduSlave04Inlet01NotOverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 input01 voltage Not over high threshold." ::= 181 ipduSlave04Inlet02OverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 input02 voltage over high threshold." ::= 182 ipduSlave04Inlet02NotOverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 input02 voltage Not over high threshold." ::= 183 ipduSlave04Inlet01UnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 input01 voltage under low threshold." ::= 184 ipduSlave04Inlet01NotUnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 input01 voltage Not under low threshold." ::= 185 ipduSlave04Inlet02UnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 input02 voltage under low threshold." ::= 186 ipduSlave04Inlet02NotUnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 input02 voltage Not under low threshold." ::= 187 ipduSlave04Inlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 input01 current over high threshold." ::= 188 ipduSlave04Inlet01NotCurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 input01 current not over high threshold." ::= 189 ipduSlave04Inlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 input02 current over high threshold." ::= 190 ipduSlave04Inlet02NotCurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 input02 current not over high threshold." ::= 191 ipduSlave04EmdTemperatureTooHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 emd Temperature Too High." ::= 192 ipduSlave04EmdTemperatureNotHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave04 emd Temperature Not High." ::= 193 ipduSlave04EmdTemperatureTooLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 emd Temperature Too Low." ::= 194 ipduSlave04EmdTemperatureNotLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave04 emd Temperature Not Low." ::= 195 ipduSlave04EmdHumidityTooHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 emd Humidity Too High." ::= 196 ipduSlave04EmdHumidityNotHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave04 emd Humidity Not High." ::= 197 ipduSlave04EmdHumidityTooLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 emd Humidity Too Low." ::= 198 ipduSlave04EmdHumidityNotLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave04 emd Humidity Not Low." ::= 199 ipduSlave04EmdAlarm1Active TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 emd Alarm1 Active." ::= 200 ipduSlave04EmdAlarm1Normal TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave04 emd Alarm1 Normal." ::= 201 ipduSlave04EmdAlarm2Active TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 emd Alarm2 Active." ::= 202 ipduSlave04EmdAlarm2Normal TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave04 emd Alarm2 Normal." ::= 203 ipduSlave04Outlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 Outlet01 Current over threshold." ::= 204 ipduSlave04Outlet01CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 Outlet01 Current not over threshold." ::= 205 ipduSlave04Outlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 Outlet02 Current over threshold." ::= 206 ipduSlave04Outlet02CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 Outlet02 Current not over threshold." ::= 207 ipduSlave04Outlet03CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 Outlet03 Current over threshold." ::= 208 ipduSlave04Outlet03CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 Outlet03 Current not over threshold." ::= 209 ipduSlave04Outlet04CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 Outlet04 Current over threshold." ::= 210 ipduSlave04Outlet04CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 Outlet04 Current not over threshold." ::= 211 ipduSlave04Outlet05CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 Outlet05 Current over threshold." ::= 212 ipduSlave04Outlet05CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 Outlet05 Current not over threshold." ::= 213 ipduSlave04Outlet06CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 Outlet06 Current over threshold." ::= 214 ipduSlave04Outlet06CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 Outlet06 Current not over threshold." ::= 215 ipduSlave04Outlet07CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 Outlet07 Current over threshold." ::= 216 ipduSlave04Outlet07CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 Outlet07 Current not over threshold." ::= 217 ipduSlave04Outlet08CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 Outlet08 Current over threshold." ::= 218 ipduSlave04Outlet08CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 Outlet08 Current not over threshold." ::= 219 ipduSlave04Outlet09CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 Outlet09 Current over threshold." ::= 220 ipduSlave04Outlet09CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 Outlet09 Current not over threshold." ::= 221 ipduSlave04Outlet10CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 Outlet10 Current over threshold." ::= 222 ipduSlave04Outlet10CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 Outlet10 Current not over threshold." ::= 223 ipduSlave04Outlet11CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 Outlet11 Current over threshold." ::= 224 ipduSlave04Outlet11CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 Outlet11 Current not over threshold." ::= 225 ipduSlave04Outlet12CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave04 Outlet12 Current over threshold." ::= 226 ipduSlave04Outlet12CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave04 Outlet12 Current not over threshold." ::= 227 --========================================================================== -- Slave05 trap --========================================================================== ipduSlave05Inlet01OverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 input01 voltage over high threshold." ::= 228 ipduSlave05Inlet01NotOverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 input01 voltage Not over high threshold." ::= 229 ipduSlave05Inlet02OverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 input02 voltage over high threshold." ::= 230 ipduSlave05Inlet02NotOverHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 input02 voltage Not over high threshold." ::= 231 ipduSlave05Inlet01UnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 input01 voltage under low threshold." ::= 232 ipduSlave05Inlet01NotUnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 input01 voltage Not under low threshold." ::= 233 ipduSlave05Inlet02UnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 input02 voltage under low threshold." ::= 234 ipduSlave05Inlet02NotUnderLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 input02 voltage Not under low threshold." ::= 235 ipduSlave05Inlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 input01 current over high threshold." ::= 236 ipduSlave05Inlet01NotCurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 input01 current not over high threshold." ::= 237 ipduSlave05Inlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 input02 current over high threshold." ::= 238 ipduSlave05Inlet02NotCurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 input02 current not over high threshold." ::= 239 ipduSlave05EmdTemperatureTooHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 emd Temperature Too High." ::= 240 ipduSlave05EmdTemperatureNotHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave05 emd Temperature Not High." ::= 241 ipduSlave05EmdTemperatureTooLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 emd Temperature Too Low." ::= 242 ipduSlave05EmdTemperatureNotLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave05 emd Temperature Not Low." ::= 243 ipduSlave05EmdHumidityTooHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 emd Humidity Too High." ::= 244 ipduSlave05EmdHumidityNotHigh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave05 emd Humidity Not High." ::= 245 ipduSlave05EmdHumidityTooLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 emd Humidity Too Low." ::= 246 ipduSlave05EmdHumidityNotLow TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave05 emd Humidity Not Low." ::= 247 ipduSlave05EmdAlarm1Active TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 emd Alarm1 Active." ::= 248 ipduSlave05EmdAlarm1Normal TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave05 emd Alarm1 Normal." ::= 249 ipduSlave05EmdAlarm2Active TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 emd Alarm2 Active." ::= 250 ipduSlave05EmdAlarm2Normal TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "INFORMATION: The Slave05 emd Alarm2 Normal." ::= 251 ipduSlave05Outlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 Outlet01 Current over threshold." ::= 252 ipduSlave05Outlet01CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 Outlet01 Current not over threshold." ::= 253 ipduSlave05Outlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 Outlet02 Current over threshold." ::= 254 ipduSlave05Outlet02CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 Outlet02 Current not over threshold." ::= 255 ipduSlave05Outlet03CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 Outlet03 Current over threshold." ::= 256 ipduSlave05Outlet03CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 Outlet03 Current not over threshold." ::= 257 ipduSlave05Outlet04CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 Outlet04 Current over threshold." ::= 258 ipduSlave05Outlet04CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 Outlet04 Current not over threshold." ::= 259 ipduSlave05Outlet05CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 Outlet05 Current over threshold." ::= 260 ipduSlave05Outlet05CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 Outlet05 Current not over threshold." ::= 261 ipduSlave05Outlet06CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 Outlet06 Current over threshold." ::= 262 ipduSlave05Outlet06CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 Outlet06 Current not over threshold." ::= 263 ipduSlave05Outlet07CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 Outlet07 Current over threshold." ::= 264 ipduSlave05Outlet07CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 Outlet07 Current not over threshold." ::= 265 ipduSlave05Outlet08CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 Outlet08 Current over threshold." ::= 266 ipduSlave05Outlet08CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 Outlet08 Current not over threshold." ::= 267 ipduSlave05Outlet09CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 Outlet09 Current over threshold." ::= 268 ipduSlave05Outlet09CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 Outlet09 Current not over threshold." ::= 269 ipduSlave05Outlet10CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 Outlet10 Current over threshold." ::= 270 ipduSlave05Outlet10CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 Outlet10 Current not over threshold." ::= 271 ipduSlave05Outlet11CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 Outlet11 Current over threshold." ::= 272 ipduSlave05Outlet11CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 Outlet11 Current not over threshold." ::= 273 ipduSlave05Outlet12CurrentOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "CRITICAL: The Slave05 Outlet12 Current over threshold." ::= 274 ipduSlave05Outlet12CurrentNotOverTh TRAP-TYPE ENTERPRISE ipduTraps DESCRIPTION "WARNING: The Slave05 Outlet12 Current not over threshold." ::= 275 END