-- ***************************************************************** -- Smartoptics SiteLight Escon Module MIB -- -- Aug 2002, Omri Viner -- -- Copyright (c) 1999-2002 by Smartoptics Ltd. -- All rights reserved. -- ***************************************************************** SL-ESCON-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Counter64, Gauge32, Integer32, mib-2 FROM SNMPv2-SMI TEXTUAL-CONVENTION, TruthValue, TimeStamp, DisplayString FROM SNMPv2-TC InterfaceIndex FROM IF-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF slService FROM SL-NE-MIB; esconMIB MODULE-IDENTITY LAST-UPDATED "0208190000Z" ORGANIZATION "Smartoptics Networks Ltd." CONTACT-INFO "E-mail: d.lutz@Smartoptics.com" DESCRIPTION "The MIB module for Escon Interface." ::= { slService 5 } esconMIBObjects OBJECT IDENTIFIER ::= { esconMIB 1 } -- Groups under esconMIBObjects esconConfig OBJECT IDENTIFIER ::= { esconMIBObjects 1 } esconPm OBJECT IDENTIFIER ::= { esconMIBObjects 2 } esconTraps OBJECT IDENTIFIER ::= { esconMIBObjects 3 } -- Textual Conventions EsconAddressId ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents Escon Address ID. Should be displayed as HH HH" SYNTAX INTEGER (0..65535) EsconNodeDescription ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents Escon Node Description." SYNTAX DisplayString (SIZE (1..32)) -- The Configuration group -- This esconPortTable contains, one entry for each Escon Port, -- configuration parameters of the ports. esconPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF EsconPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each port." ::= { esconConfig 1 } esconPortConfigEntry OBJECT-TYPE SYNTAX EsconPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing the result configuration and service parameters of a port." INDEX { esconPortConfigIndex } ::= { esconPortConfigTable 1 } EsconPortConfigEntry ::= SEQUENCE { esconPortConfigIndex InterfaceIndex, esconPortConfigSrcAddress EsconAddressId, esconPortConfigSrcDescription EsconNodeDescription, esconPortConfigTranceiverMedia -- deprecated INTEGER, esconPortConfigResetPmCounters INTEGER, esconPortConfigTranceiverType -- deprecated INTEGER, esconPortConfigStatus INTEGER, esconPortConfigValidIntervals INTEGER, esconPortConfigLoginState BITS, esconPortResetPmCounters INTEGER } esconPortConfigIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex of the port." ::= { esconPortConfigEntry 1 } esconPortConfigSrcAddress OBJECT-TYPE SYNTAX EsconAddressId MAX-ACCESS read-only STATUS current DESCRIPTION "The source address of the physical path of this port. This value is valid only when state is validLogin(2)." ::= { esconPortConfigEntry 2 } esconPortConfigSrcDescription OBJECT-TYPE SYNTAX EsconNodeDescription MAX-ACCESS read-only STATUS current DESCRIPTION "The description of the attached node. This value is valid only when state is validLogin(2)." ::= { esconPortConfigEntry 3 } esconPortConfigTranceiverMedia OBJECT-TYPE SYNTAX INTEGER { none(1), sm(2), -- single-mode mm(3) -- multi-mode } MAX-ACCESS read-only STATUS current -- deprecated DESCRIPTION "The tranceiver media." ::= { esconPortConfigEntry 4 } esconPortConfigResetPmCounters OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this variable to 1 will cause the current interval PM counters of the port to be initialized to zero (0)." ::= { esconPortConfigEntry 5 } esconPortConfigTranceiverType OBJECT-TYPE SYNTAX INTEGER { none(1), shortWave(2), -- 850nm longWave(3) -- 1310nm } MAX-ACCESS read-only STATUS current -- deprecated DESCRIPTION "The tranceiver type." ::= { esconPortConfigEntry 6 } esconPortConfigStatus OBJECT-TYPE SYNTAX INTEGER (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Line Status of the ESCON interface. The esconPortStatus is a bit map represented as a sum, therefore, it can represent multiple failures (alarms) simultaneously. esconPortNoAlarm must be set if and only if no other flag is set. The various bit positions are: 1 esconPortNoAlarm No alarm present 2 esconPortTransmitFault Transceiver transmit fault 4 esconPortLossOfSignal Transceiver signal detect failed 8 esconPortNoLink No link established yet." ::= { esconPortConfigEntry 7 } esconPortConfigValidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous near end intervals for which data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online. In the case where the agent is a proxy, it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available." ::= { esconPortConfigEntry 8 } esconPortConfigLoginState OBJECT-TYPE SYNTAX BITS { signalSense(0), syncPort(1), validLogin(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The high bit signalSense(0) means that a physical connection has been established with the attached port. The high bit syncPort(1) means that the there there is a sequence synchronization with the attached port. The high bit validLogin(2) indicates that the physical path has been established." ::= { esconPortConfigEntry 9 } esconPortResetPmCounters OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this variable to 1 will cause the current interval Escon PM counters of the port to be initialized to zero (0)." ::= { esconPortConfigEntry 10 } -- PM Group -- -- Consists of the the following objects: -- 1. esconPortCurrentTable - the current PM counters -- 2. esconPortIntervalTable - keeps the history of the 1-32/96 intervals -- of 15 minutes PM counters. -- 3. esconPortTotalTable - the total PM counters of the previous 24 hours -- 4. esconPortThresholdTable - the threshold for the current PM counters. -- When crossing a threshold the TCA alarm is generated. -- -- The PM Current Table esconPortCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF EsconPortCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ESCON current table contains various statistics being collected for the current 15 minute interval." ::= { esconPm 1 } esconPortCurrentEntry OBJECT-TYPE SYNTAX EsconPortCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Escon Current table." INDEX { esconPortCurrentIndex } ::= { esconPortCurrentTable 1 } EsconPortCurrentEntry ::= SEQUENCE { esconPortCurrentIndex InterfaceIndex, -- ingress esconPortCurrentRxOctets Counter64, esconPortCurrentRxPkts Counter64, esconPortCurrentRxSigLosses Counter64, esconPortCurrentRxSyncLosses Counter64, esconPortCurrentRxLinkFailures Counter64, esconPortCurrentRxInvalidCrcs Counter64, esconPortCurrentRxDelimiterErrors Counter64, esconPortCurrentRxSizeFrames Counter64, esconPortCurrentRxDisparityErrors Counter64, esconPortCurrentRxInvalidTxWords Counter64, -- egress esconPortCurrentTxOctets Counter64, esconPortCurrentTxPkts Counter64, esconPortCurrentTxHeaderError Counter64, esconPortCurrentTxJitterUnderflow Counter64 } esconPortCurrentIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The index value which uniquely identifies the ESCON interface to which this entry is applicable." ::= { esconPortCurrentEntry 1 } esconPortCurrentRxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of octets of data received during the current interval." ::= { esconPortCurrentEntry 2 } esconPortCurrentRxPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets (including bad packets) received during the current interval." ::= { esconPortCurrentEntry 3 } esconPortCurrentRxSigLosses OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of loss of signal detected during this current interval." ::= { esconPortCurrentEntry 4 } esconPortCurrentRxSyncLosses OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of loss of synchronization detected during this current interval." ::= { esconPortCurrentEntry 5 } esconPortCurrentRxLinkFailures OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of link failures detected during this current interval." ::= { esconPortCurrentEntry 6 } esconPortCurrentRxInvalidCrcs OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of invalid CRC detected during this current interval." ::= { esconPortCurrentEntry 7 } esconPortCurrentRxDelimiterErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Delimiter Errors detected during this current interval." ::= { esconPortCurrentEntry 8 } esconPortCurrentRxDisparityErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Disparity Errors detected during this current interval." ::= { esconPortCurrentEntry 9 } esconPortCurrentRxSizeFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of too short or too long frames detected during this current interval." ::= { esconPortCurrentEntry 10 } esconPortCurrentRxInvalidTxWords OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of invalid transmission word detected during this current interval." ::= { esconPortCurrentEntry 11 } esconPortCurrentTxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets of data transmited during the current interval." ::= { esconPortCurrentEntry 12 } esconPortCurrentTxPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets (including bad packets) transmitted during the current interval." ::= { esconPortCurrentEntry 13 } esconPortCurrentTxHeaderError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PL-ESC header error transmitted during the current interval." ::= { esconPortCurrentEntry 14 } esconPortCurrentTxJitterUnderflow OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Jitter buffer underflow occurences during the current interval." ::= { esconPortCurrentEntry 15 } -- The PM Interval Table esconPortIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF EsconPortIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ESCON In table contains various statistics being collected for the 15 minute intervals." ::= { esconPm 2 } esconPortIntervalEntry OBJECT-TYPE SYNTAX EsconPortIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ESCON Interval table." INDEX { esconPortIntervalIndex, esconPortIntervalNumber } ::= { esconPortIntervalTable 1 } EsconPortIntervalEntry ::= SEQUENCE { esconPortIntervalIndex InterfaceIndex, esconPortIntervalNumber INTEGER, -- ingress esconPortIntervalRxOctets Counter64, esconPortIntervalRxPkts Counter64, esconPortIntervalRxSigLosses Counter64, esconPortIntervalRxSyncLosses Counter64, esconPortIntervalRxLinkFailures Counter64, esconPortIntervalRxInvalidCrcs Counter64, esconPortIntervalRxDelimiterErrors Counter64, esconPortIntervalRxSizeFrames Counter64, esconPortIntervalRxDisparityErrors Counter64, esconPortIntervalRxInvalidTxWords Counter64, -- egress esconPortIntervalTxOctets Counter64, esconPortIntervalTxPkts Counter64, esconPortIntervalTxHeaderError Counter64, esconPortIntervalTxJitterUnderflow Counter64, -- general esconPortIntervalValidData TruthValue, esconPortIntervalTcaFlag TruthValue } esconPortIntervalIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The index value which uniquely identifies the Escon interface to which this entry is applicable." ::= { esconPortIntervalEntry 1 } esconPortIntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the 15 minutes interval completed 23 hours and 45 minutes prior to interval 1." ::= { esconPortIntervalEntry 2 } esconPortIntervalRxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets of data received during the sampling interval." ::= { esconPortIntervalEntry 3 } esconPortIntervalRxPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets (including bad packets) received during the sampling interval." ::= { esconPortIntervalEntry 4 } esconPortIntervalRxSigLosses OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of loss of signal detected during this sampling interval." ::= { esconPortIntervalEntry 5 } esconPortIntervalRxSyncLosses OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of loss of synchronization detected during this sampling interval." ::= { esconPortIntervalEntry 6 } esconPortIntervalRxLinkFailures OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of link failures detected during this sampling interval." ::= { esconPortIntervalEntry 7 } esconPortIntervalRxInvalidCrcs OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of invalid CRC detected during this sampling interval." ::= { esconPortIntervalEntry 8 } esconPortIntervalRxDelimiterErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Delimiter Errors detected during this sampling interval." ::= { esconPortIntervalEntry 9 } esconPortIntervalRxDisparityErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Disparity Errors detected during this sampling interval." ::= { esconPortIntervalEntry 10 } esconPortIntervalRxSizeFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of too short or too long frames detected during this sampling interval." ::= { esconPortIntervalEntry 11 } esconPortIntervalRxInvalidTxWords OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The current number of invalid transmission word detected during this sampling interval." ::= { esconPortIntervalEntry 12 } esconPortIntervalTxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets of data transmited during the sampling interval." ::= { esconPortIntervalEntry 13 } esconPortIntervalTxPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets (including bad packets) transmitted during the sampling interval." ::= { esconPortIntervalEntry 14 } esconPortIntervalTxHeaderError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PL-ESC header error transmitted during the sampling interval." ::= { esconPortIntervalEntry 15 } esconPortIntervalTxJitterUnderflow OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Jitter buffer underflow occurences during the sampling interval." ::= { esconPortIntervalEntry 16 } esconPortIntervalValidData OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates if the data for this interval is valid." ::= { esconPortIntervalEntry 17 } esconPortIntervalTcaFlag OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "TRUE if one of the counters crossed the threshold during the interval." ::= { esconPortIntervalEntry 18 } -- The PM Total Table esconPortTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF EsconPortTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Escon current table contains various statistics being collected for the pervious 24 hours. interval." ::= { esconPm 3 } esconPortTotalEntry OBJECT-TYPE SYNTAX EsconPortTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Escon Total table." INDEX { esconPortTotalIndex, esconPortTotalDayNumber } ::= { esconPortTotalTable 1 } EsconPortTotalEntry ::= SEQUENCE { esconPortTotalIndex InterfaceIndex, esconPortTotalDayNumber INTEGER, -- ingress esconPortTotalRxOctets Counter64, esconPortTotalRxPkts Counter64, esconPortTotalRxSigLosses Counter64, esconPortTotalRxSyncLosses Counter64, esconPortTotalRxLinkFailures Counter64, esconPortTotalRxInvalidCrcs Counter64, esconPortTotalRxDelimiterErrors Counter64, esconPortTotalRxSizeFrames Counter64, esconPortTotalRxDisparityErrors Counter64, esconPortTotalRxInvalidTxWords Counter64, -- egress esconPortTotalTxOctets Counter64, esconPortTotalTxPkts Counter64, esconPortTotalTxHeaderError Counter64, esconPortTotalTxJitterUnderflow Counter64, -- general esconPortTotalValidData TruthValue, esconPortTotalTcaFlag TruthValue } esconPortTotalIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The index value which uniquely identifies the Escon interface to which this entry is applicable." ::= { esconPortTotalEntry 1 } esconPortTotalDayNumber OBJECT-TYPE SYNTAX INTEGER (1..33) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A number which identifies the 1-day interval for which the set of section related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval." ::= { esconPortTotalEntry 2 } esconPortTotalRxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of octets of data received during the sampling interval." ::= { esconPortTotalEntry 3 } esconPortTotalRxPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) received during the sampling interval." ::= { esconPortTotalEntry 4 } esconPortTotalRxSigLosses OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of loss of signal detected during this sampling interval." ::= { esconPortTotalEntry 5 } esconPortTotalRxSyncLosses OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of loss of synchronization detected during this sampling interval." ::= { esconPortTotalEntry 6 } esconPortTotalRxLinkFailures OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of link failures detected during this sampling interval." ::= { esconPortTotalEntry 7 } esconPortTotalRxInvalidCrcs OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of invalid CRC detected during this sampling interval." ::= { esconPortTotalEntry 8 } esconPortTotalRxDelimiterErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of Delimiter Errors detected during this sampling interval." ::= { esconPortTotalEntry 9 } esconPortTotalRxDisparityErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of Disparity Errors detected during this sampling interval." ::= { esconPortTotalEntry 10 } esconPortTotalRxSizeFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of too short or too long frames detected during this sampling interval." ::= { esconPortTotalEntry 11 } esconPortTotalRxInvalidTxWords OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of invalid transmission word detected during this sampling interval." ::= { esconPortTotalEntry 12 } esconPortTotalTxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of octets of data transmited during the sampling interval." ::= { esconPortTotalEntry 13 } esconPortTotalTxPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets (including bad packets) transmitted during the sampling interval." ::= { esconPortTotalEntry 14 } esconPortTotalTxHeaderError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of PL-ESC header error transmitted during the sampling interval." ::= { esconPortTotalEntry 15 } esconPortTotalTxJitterUnderflow OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of Jitter buffer underflow occurences during the sampling interval." ::= { esconPortTotalEntry 16 } esconPortTotalValidData OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates if the data for this interval is valid." ::= { esconPortTotalEntry 17 } esconPortTotalTcaFlag OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "TRUE if one of the counters crossed the threshold during the interval." ::= { esconPortTotalEntry 18 } -- -- The PM Interval Threshold Table -- esconPortIntervalThresholdTable OBJECT-TYPE SYNTAX SEQUENCE OF EsconPortIntervalThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Escon Threshold Table contains Interval thresholds for the PM counters collected by each Escon Interface (identified by esconPortIntervalThresholdIndex)." ::= { esconPm 4 } esconPortIntervalThresholdEntry OBJECT-TYPE SYNTAX EsconPortIntervalThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Escon Interval Threshold table." INDEX { esconPortIntervalThresholdIndex } ::= { esconPortIntervalThresholdTable 1 } EsconPortIntervalThresholdEntry ::= SEQUENCE { esconPortIntervalThresholdIndex InterfaceIndex, -- ingress esconPortIntervalThresholdRxSigLosses Counter64, esconPortIntervalThresholdRxSyncLosses Counter64, esconPortIntervalThresholdRxLinkFailures Counter64, esconPortIntervalThresholdRxInvalidCrcs Counter64, esconPortIntervalThresholdRxDelimiterErrors Counter64, esconPortIntervalThresholdRxSizeFrames Counter64, esconPortIntervalThresholdRxDisparityErrors Counter64, esconPortIntervalThresholdRxInvalidTxWords Counter64, -- egress esconPortIntervalThresholdTxHeaderError Counter64, esconPortIntervalThresholdTxJitterUnderflow Counter64 } esconPortIntervalThresholdIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The index value which uniquely identifies the Escon interface to which this entry is applicable." ::= { esconPortIntervalThresholdEntry 1 } esconPortIntervalThresholdRxSigLosses OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of signal loss detection." ::= { esconPortIntervalThresholdEntry 2 } esconPortIntervalThresholdRxSyncLosses OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of synchronization loss detection." ::= { esconPortIntervalThresholdEntry 3 } esconPortIntervalThresholdRxLinkFailures OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of link failures detection." ::= { esconPortIntervalThresholdEntry 4 } esconPortIntervalThresholdRxInvalidCrcs OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of invalid CRC detection." ::= { esconPortIntervalThresholdEntry 5 } esconPortIntervalThresholdRxDelimiterErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of Delimiter Errors detection." ::= { esconPortIntervalThresholdEntry 6 } esconPortIntervalThresholdRxDisparityErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of Disparity Errors detection." ::= { esconPortIntervalThresholdEntry 7 } esconPortIntervalThresholdRxSizeFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of too short or too long frames errors detection." ::= { esconPortIntervalThresholdEntry 8 } esconPortIntervalThresholdRxInvalidTxWords OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of invalid transmission word detection." ::= { esconPortIntervalThresholdEntry 9 } esconPortIntervalThresholdTxHeaderError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number PL-ESC header transmitted detection." ::= { esconPortIntervalThresholdEntry 10 } esconPortIntervalThresholdTxJitterUnderflow OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of Jitter buffer underflow detection." ::= { esconPortIntervalThresholdEntry 11 } -- -- The PM Day Threshold Table -- esconPortDayThresholdTable OBJECT-TYPE SYNTAX SEQUENCE OF EsconPortDayThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Escon Threshold Table contains Day thresholds for the PM counters collected by each Escon Interface (identified by esconPortDayThresholdIndex)." ::= { esconPm 5 } esconPortDayThresholdEntry OBJECT-TYPE SYNTAX EsconPortDayThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Escon Day Threshold table." INDEX { esconPortDayThresholdIndex } ::= { esconPortDayThresholdTable 1 } EsconPortDayThresholdEntry ::= SEQUENCE { esconPortDayThresholdIndex InterfaceIndex, -- ingress esconPortDayThresholdRxSigLosses Counter64, esconPortDayThresholdRxSyncLosses Counter64, esconPortDayThresholdRxLinkFailures Counter64, esconPortDayThresholdRxInvalidCrcs Counter64, esconPortDayThresholdRxDelimiterErrors Counter64, esconPortDayThresholdRxSizeFrames Counter64, esconPortDayThresholdRxDisparityErrors Counter64, esconPortDayThresholdRxInvalidTxWords Counter64, -- egress esconPortDayThresholdTxHeaderError Counter64, esconPortDayThresholdTxJitterUnderflow Counter64 } esconPortDayThresholdIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The index value which uniquely identifies the Escon interface to which this entry is applicable." ::= { esconPortDayThresholdEntry 1 } esconPortDayThresholdRxSigLosses OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of signal loss detection." ::= { esconPortDayThresholdEntry 2 } esconPortDayThresholdRxSyncLosses OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of synchronization loss detection." ::= { esconPortDayThresholdEntry 3 } esconPortDayThresholdRxLinkFailures OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of link failures detection." ::= { esconPortDayThresholdEntry 4 } esconPortDayThresholdRxInvalidCrcs OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of invalid CRC detection." ::= { esconPortDayThresholdEntry 5 } esconPortDayThresholdRxDelimiterErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of Delimiter Errors detection." ::= { esconPortDayThresholdEntry 6 } esconPortDayThresholdRxDisparityErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of Disparity Errors detection." ::= { esconPortDayThresholdEntry 7 } esconPortDayThresholdRxSizeFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of too short or too long frames errors detection." ::= { esconPortDayThresholdEntry 8 } esconPortDayThresholdRxInvalidTxWords OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of invalid transmission word detection." ::= { esconPortDayThresholdEntry 9 } esconPortDayThresholdTxHeaderError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number PL-ESC header transmitted detection." ::= { esconPortDayThresholdEntry 10 } esconPortDayThresholdTxJitterUnderflow OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the number of Jitter buffer underflow detection." ::= { esconPortDayThresholdEntry 11 } -- Escon Traps esconCounterId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only -- accessible-for-notify STATUS current DESCRIPTION "The OBJECT IDENTIFIER of the instance of the Escon counter that has crossed its threshold." ::= { esconTraps 1 } esconCounterValue OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only -- accessible-for-notify STATUS current DESCRIPTION "The current value of the Escon counter that has crossed its threshold." ::= { esconTraps 2 } esconPortThresholdCrossing NOTIFICATION-TYPE OBJECTS { esconCounterId, esconCounterValue } STATUS current DESCRIPTION "A esconPortThresholdCrossing trap is sent when the a PM counter exceeded the specified threshold." ::= { esconTraps 3 } esconPortStatusChange NOTIFICATION-TYPE OBJECTS { esconPortConfigIndex, esconPortConfigStatus } STATUS current DESCRIPTION "A esconPortStatusChange trap is sent when the value of an instance esconPortConfigStatus changes. It can be utilized by an NMS to trigger polls." ::= { esconTraps 4 } END