RUGGEDCOM-IRIGB-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, NOTIFICATION-TYPE FROM SNMPv2-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC OBJECT-GROUP FROM SNMPv2-CONF ruggedcomMgmt, ruggedcomTraps FROM RUGGEDCOM-MIB RcTimeSyncStatus FROM RUGGEDCOM-TIMECONFIG-MIB; rcIrigb MODULE-IDENTITY LAST-UPDATED "201510301700Z" -- Oct 30, 17:00 EST 2015 ORGANIZATION "Siemens Canada Limited" CONTACT-INFO "Postal: Siemens Canada Limited 300 Applewood Crescent Concord, Ontario, L4K 5C7 Canada Tel: 1-905-856-5288 E-Mail: support@ruggedcom.com" DESCRIPTION "Siemens - RuggedCom proprietary to control and monitor IRIGB module." REVISION "201510301700Z" -- Oct 30, 17:00 EST 2015 DESCRIPTION "Added objects to configure and monitor IRIGB in RuggedCom devices." REVISION "201412011700Z" -- Dec 01, 17:00 EST 2014 DESCRIPTION "Initial version of Siemens - RuggedCom proprietary MIB to control and monitor IRIGB module." ::= { ruggedcomMgmt 10 } --------------------------------------------------------------- -- Textual Conventions --------------------------------------------------------------- RcTimeStamp ::= TEXTUAL-CONVENTION DISPLAY-HINT "4d.4d" STATUS current DESCRIPTION "Timestamps are represented as a 64-bit unsigned fixed-point number in seconds relative to 00:00 on 1 January 1970. The integer part is in the first 32 bits and the fraction part is in the last 32 bits." SYNTAX OCTET STRING (SIZE (8)) -- ---------------------------------------------------------- -- -- rcIrigb subtrees -- ---------------------------------------------------------- -- rcIrigbBase OBJECT IDENTIFIER ::= { rcIrigb 1 } rcIrigbConformance OBJECT IDENTIFIER ::= { rcIrigb 2 } rcIrigbGroups OBJECT IDENTIFIER ::= { rcIrigbConformance 2 } -- ---------------------------------------------------------------------- -- -- Base subtree -- ---------------------------------------------------------------------- -- rcIrigbStatus OBJECT-TYPE SYNTAX RcTimeSyncStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The system synchronization status when IRIGB is a primary time source. If value of this object is changed, rcIrigbStatusChange notification will be sent." ::= { rcIrigbBase 1} rcIrigbAMOutput OBJECT-TYPE SYNTAX INTEGER { off(1), am(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects AM (Amplitude Modulation) mode of IRIGB port." REFERENCE "AM mode complies with IRIG Standard 200-04." ::= { rcIrigbBase 2} rcIrigbTimeCode OBJECT-TYPE SYNTAX INTEGER { bxx0(1), bxx1(2), bxx2(3), bxx3(4), bxx4(5), bxx5(6), bxx6(7), bxx7(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This device uses the following convention to decode the IRIGB time code: letter [B] represents IRIG-B format, [xx] represents [00] for PWM/TTL mode of operation and [12] for AM operation. For example, Bxx7 represents B007 for PWM/TTL operation and B127 for AM operation. Please note that only Bxx0, Bxx1, Bxx4 and Bxx5 time codes support IRIGB extensions." ::= { rcIrigbBase 3} rcIrigbExt OBJECT-TYPE SYNTAX INTEGER { off(1), ieee1344(2), c37-118-2005(3), c37-118-2011(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "IRIGB extensions use extra bits of the Control Functions (CF) portion of the IRIGB time code. Within this portion of the time code, bits are designated for additional features, including: Calendar Year, Leap seconds, leap seconds pending, Daylight Saving Time (DST), DST pending, local time offset and time quality. Please note that only Bxx0, Bxx1, Bxx4 and Bxx5 time codes support IRIGB extensions." ::= { rcIrigbBase 4} rcIrigbInput OBJECT-TYPE SYNTAX INTEGER { off(1), pwm(2), pps(3), am(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects operational mode of IRIGB input port. IRIGB module is capable of interpreting IRIGB extensions such as C37.118-2011, C37.118-2005 and IEEE1344." REFERENCE "C37.118-2011, C37.118-2005 and IEEE1344." ::= { rcIrigbBase 5} rcIrigbLockInt OBJECT-TYPE SYNTAX Integer32(1..120) MAX-ACCESS read-write STATUS current DESCRIPTION "To set time interval in minute with in which IRIGB receiver should acquire lock to the time source. Normally IRIGB receiver needs couple of minutes to lock the signal. User should set reasonable time interval. If time interval expire with out acquire the lock then system start distributing the time using local clock." ::= { rcIrigbBase 6} rcIrigbCableComp OBJECT-TYPE SYNTAX Integer32(0..50000) MAX-ACCESS read-write STATUS current DESCRIPTION "Cable compensation in ns may be desired to compensate for a long cable run in order to minimize the timing inaccuracy." ::= { rcIrigbBase 7} rcIrigbOFM OBJECT-TYPE SYNTAX Integer32(-2147483647..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The current time offset between system and reference clocks." ::= { rcIrigbBase 8} rcIrigbFreqAdj OBJECT-TYPE SYNTAX Integer32(-2147483647..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The current amount of discipline applied to the local frequency reference (TCXO)." ::= { rcIrigbBase 9} rcIrigbOutputPWM1 OBJECT-TYPE SYNTAX INTEGER { off(1), pwm(2), pps(3), ppx(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects Operational mode of TTL output port. PWM mode complies with IRIG Standard 200-04. PPx provides generic pulse per x second interface to synchronize external devices." ::= { rcIrigbBase 10} rcIrigbPulseInterval1 OBJECT-TYPE SYNTAX Integer32(1..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "Selects Pulse Interval in s for TTL output port. This parameter is used in conjunction with PPx in order to provides generic pulse per x second interface to synchronize external devices." ::= { rcIrigbBase 11} rcIrigbPulseWidth1 OBJECT-TYPE SYNTAX Integer32(1..200) MAX-ACCESS read-write STATUS current DESCRIPTION "Selects Pulse Width in ms for TTL output port. This parameter is used in conjunction with PPx to control the width of the pulse." ::= { rcIrigbBase 12} rcIrigbStartTime1 OBJECT-TYPE SYNTAX RcTimeStamp MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used in conjunction with PPx to set the starting time of first PPx event. Note that this parameter must be set at least 15 seconds before the start of desired PPx otherwise first PPx event might be lost." ::= { rcIrigbBase 13} rcIrigbOutputPWM2 OBJECT-TYPE SYNTAX INTEGER { off(1), pwm(2), pps(3), ppx(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects Operational mode of TTL output port2. PWM mode complies with IRIG Standard 200-04. PPx provides generic pulse per x second interface to synchronize external devices." REFERENCE "IRIGB Standard 200-04." ::= { rcIrigbBase 14} rcIrigbPulseInterval2 OBJECT-TYPE SYNTAX Integer32(1..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "Selects Pulse Interval in s for TTL output port2. This parameter is used in conjunction with PPx in order to provides generic pulse per x second interface to synchronize external devices." ::= { rcIrigbBase 15} rcIrigbPulseWidth2 OBJECT-TYPE SYNTAX Integer32(1..200) MAX-ACCESS read-write STATUS current DESCRIPTION "Selects Pulse Width in ms for TTL output port2. This parameter is used in conjunction with PPx to control the width of the pulse." ::= { rcIrigbBase 16} rcIrigbStartTime2 OBJECT-TYPE SYNTAX RcTimeStamp MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used in conjunction with PPx to set the starting time of first PPx event. Note that this parameter must be set at least 15 seconds before the start of desired PPx otherwise first PPx event might be lost." ::= { rcIrigbBase 17} -- ---------------------------------------------------------------------- -- -- Traps -- ---------------------------------------------------------------------- -- rcIrigbStatusChange NOTIFICATION-TYPE OBJECTS { rcIrigbStatus } STATUS current DESCRIPTION "Notification generated if status of the IRIGB module is changed." ::= { ruggedcomTraps 35 } -- ---------------------------------------------------------------------- -- -- Conformance Groups -- ---------------------------------------------------------------------- -- rcIrigbBaseGroup OBJECT-GROUP OBJECTS { rcIrigbStatus } STATUS current DESCRIPTION "A group of objects providing ability ability to monitor and configure IRIGB status." ::= { rcIrigbGroups 1 } rcIrigbNotifyGroup OBJECT-GROUP OBJECTS { rcIrigbStatusChange } STATUS current DESCRIPTION "A group of objects that define trap." ::= { rcIrigbGroups 2 } rcIrigbCommonGroup OBJECT-GROUP OBJECTS { rcIrigbStatus, rcIrigbTimeCode, rcIrigbExt, rcIrigbLockInt, rcIrigbCableComp, rcIrigbOFM, rcIrigbFreqAdj } STATUS current DESCRIPTION "A group of objects providing ability to monitor and configure IRIGB device." ::= { rcIrigbGroups 3 } rcIrigbAMOutGroup OBJECT-GROUP OBJECTS { rcIrigbAMOutput } STATUS current DESCRIPTION "A group of objects providing ability to configure IRIGB AM output interface." ::= { rcIrigbGroups 4 } rcIrigbInputGroup OBJECT-GROUP OBJECTS { rcIrigbInput } STATUS current DESCRIPTION "This parameter covers both AM and PWM inputs." ::= { rcIrigbGroups 5 } rcIrigbTTLOutput01Group OBJECT-GROUP OBJECTS { rcIrigbOutputPWM1, rcIrigbPulseInterval1, rcIrigbPulseWidth1, rcIrigbStartTime1 } STATUS current DESCRIPTION "A group of objects providing ability to configure IRIGB TTL output interface01." ::= { rcIrigbGroups 6 } rcIrigbTTLOutput02Group OBJECT-GROUP OBJECTS { rcIrigbOutputPWM2, rcIrigbPulseInterval2, rcIrigbPulseWidth2, rcIrigbStartTime2 } STATUS current DESCRIPTION "A group of objects providing ability to configure IRIGB TTL output interface02." ::= { rcIrigbGroups 7 } END