RUGGEDCOM-DOT11-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, IpAddress, Unsigned32, TimeTicks FROM SNMPv2-SMI OBJECT-GROUP FROM SNMPv2-CONF DisplayString, MacAddress, TruthValue FROM SNMPv2-TC ruggedcomMgmt FROM RUGGEDCOM-MIB; rcDot11 MODULE-IDENTITY LAST-UPDATED "200902271000Z" -- Feb 27, 10:00 EST 2009 ORGANIZATION "RuggedCom" CONTACT-INFO "Postal: RuggedCom Inc. 300 Applewood Crescent Concord, Ontario, L4K 5C7 Canada Tel: 1-905-856-5288 E-Mail: support@ruggedcom.com" DESCRIPTION "RuggedCom MIB for Managing Wireless Interface on RuggedCom Devices." ::= { ruggedcomMgmt 4 } -- ---------------------------------------------------------------------- -- -- rcDot11 subtrees -- ---------------------------------------------------------------------- -- rcDot11GlobalParams OBJECT-IDENTITY STATUS current DESCRIPTION "The main subtree for managing system wide parameters as applicable to wireless interface." ::= { rcDot11 1 } rcDot11NetworkParams OBJECT-IDENTITY STATUS current DESCRIPTION "The main subtree for managing Wireless Network related parameteres of wireless interface." ::= { rcDot11 2 } rcDot11SecurityParams OBJECT-IDENTITY STATUS current DESCRIPTION "The main subtree for managing Security parameteres on wireless interface." ::= { rcDot11 3 } rcDot11MacFiltering OBJECT-IDENTITY STATUS current DESCRIPTION "The main subtree for managaing Mac Filtering options and entries for the wireless interface." ::= { rcDot11 4 } rcDot11DhcpParams OBJECT-IDENTITY STATUS current DESCRIPTION "The main subtree for managing DHCP client-server communication for wireless interfaces." ::= { rcDot11 5 } rcDot11AssociationInfo OBJECT-IDENTITY STATUS current DESCRIPTION "The main subtree for managing information related to associated stations on the wireless interface." ::= { rcDot11 6 } -- ---------------------------------------------------------------------- -- -- branches rcDot11 7,8 and 9 are reserved for future use -- ---------------------------------------------------------------------- -- rcDot11Conformance OBJECT IDENTIFIER ::= { rcDot11 10 } -- rcDot11Compliances OBJECT IDENTIFIER ::= { rcDot11Conformance 1 } rcDot11Groups OBJECT IDENTIFIER ::= { rcDot11Conformance 2 } -- ---------------------------------------------------------------------- -- -- rcDot11GlobalParams Interface objects -- ---------------------------------------------------------------------- -- rcDot11OpMode OBJECT-TYPE SYNTAX INTEGER { ap(1), clientBridge(2), clientIpBridge(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Operational mode of wireless interface." ::= { rcDot11GlobalParams 1} rcDot11RFMAC OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC address assigned to the wireless interface side to operate in WLAN. Wired interface side is actually WLAN port of the switch and it is represented as an interface entry of ifTable." ::= { rcDot11GlobalParams 2} rcDot11IpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP Address assigned to the wireless interface. Note that wireless interface resides on a daughter card and is supported by separate IP stack." ::= { rcDot11GlobalParams 3} rcDot11IpSubnet OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The subnet mask associated with rcDot11SysIpAddress. The value of the mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0. Note that wireless interface resides on a daughter card and is supported by separate IP stack." ::= { rcDot11GlobalParams 4} rcDot11DefaultGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The default IP Gateway for the wireless interface. Note that wireless interface resides on a daughter card and is supported by separate IP stack." ::= { rcDot11GlobalParams 5} rcDot11Status OBJECT-TYPE SYNTAX INTEGER { unknown(1), booting(2), running(3), cmdProcessing(4), softwareUpgrade(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of the wireless interface." ::= { rcDot11GlobalParams 6} rcDot11UpTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The time since the daughter card was last re-initialized." ::= { rcDot11GlobalParams 7} rcDot11Version OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the WLAN firmware residing on the wireless daughter card." ::= { rcDot11GlobalParams 8} rcDot11TftpServerIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the TFTP server where the WLAN firmware is located. Note that rcDot11IpAddress and rcDot11TftpServerIpAddress must be on the same IP subnet." ::= { rcDot11GlobalParams 9} rcDot11SwUpgrade OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value of this object to 'true(1)' will start firmware upgrade procedure for the wireless daughter card. Note that this upgrade will take approximately 15 mintues to complete." ::= { rcDot11GlobalParams 10} rcDot11SwUpgradeStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Current status of the software upgrade process for the wireless daughter card." ::= { rcDot11GlobalParams 11} rcDot11WlanReset OBJECT-TYPE SYNTAX INTEGER { none(1), fullReset(2), quickReset(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The software controlled WLAN interface reset functionality. Setting the value of this object to 'fullReset(2)' will reset to both, the RF and Ethernet interfaces of WLAN (duration is approx 70 seconds). Setting the value of this object to 'quickReset(3)' will reset only the RF interface of WLAN (duration is approx 10 seconds). As a result of Read request the agent will return value 'none(1)'. NOTE: The daughter card must be reset, to activate any newly applied WLAN parameter(s). Most WLAN parameters only require a 'quickReset(3)' to take effect, and it is also acceptable for the user to issue a single reset command, even after several multiple WLAN parameters may have been changed." ::= { rcDot11GlobalParams 12} -- ---------------------------------------------------------------------- -- -- rcDot11NetworkParams objects -- ---------------------------------------------------------------------- -- rcDot11NetworkPhyMode OBJECT-TYPE SYNTAX INTEGER { auto(1), dot11b(2), dot11g(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The wireless mode running on the wireless network. Setting the value of this object to 'auto(1)' will allow Access Point to select the wireless mode. Setting the value of this object to 'dot11b(2) allows 802.11b mode only (up to 11 Mbps). Setting the value of this object to 'dot11g(3) allows 802.11g mode with 802.11b compatibility (up to 54 Mbps)" ::= { rcDot11NetworkParams 1} rcDot11NetworkDesiredSsid OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "The Service Set ID (SSID). This value is a unique name which is used to identify the wireless network for an Access Point(AP)." ::= { rcDot11NetworkParams 2} rcDot11NetworkPrimarySsid OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "The Service Set ID (SSID). This value is a unique name which is used to identify the Primary Network for a ClientBridge or ClientIpBridge. Note that for wireless clients upto three networks are supported, identified by objects rcDot11PrimaryNetworkSsid, rcDot11SecondaryNetwork1Ssid and rcDot11SecondaryNetwork2Ssid. If the rcDot11PrimaryNetworkSsid network is unavailable then Client will try to connect to rcDot11SecondaryNetwork1Ssid network and then rcDot11SecondaryNetwork2Ssid if rcDot11SecondaryNetwork1Ssid is also unavailable. In this way wireless network achieves simple redundancy through this technique." ::= { rcDot11NetworkParams 3} rcDot11NetworkSecondary1Ssid OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "The Service Set ID (SSID). This value is a unique name which is used to identify the First secondary network (Secondary 1) for a ClientBridge or ClientIpBridge. Note that for wireless clients upto three networks are supported, identified by objects rcDot11PrimaryNetworkSsid, rcDot11SecondaryNetwork1Ssid and rcDot11SecondaryNetwork2Ssid. If the rcDot11PrimaryNetworkSsid network is unavailable then Client will try to connect to rcDot11SecondaryNetwork1Ssid network and then rcDot11SecondaryNetwork2Ssid if rcDot11SecondaryNetwork1Ssid is also unavailable. In this way wireless network achieves simple redundancy through this technique." ::= { rcDot11NetworkParams 4} rcDot11NetworkSecondary2Ssid OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "The Service Set ID (SSID). This value is a unique name which is used to identify the Second Secondary network (Secondary 2) for a ClientBridge or ClientIpBridge. Note that for wireless clients upto three networks are supported, identified by objects rcDot11PrimaryNetworkSsid, rcDot11SecondaryNetwork1Ssid and rcDot11SecondaryNetwork2Ssid. If the rcDot11PrimaryNetworkSsid network is unavailable then Client will try to connect to rcDot11SecondaryNetwork1Ssid network and then rcDot11SecondaryNetwork2Ssid if rcDot11SecondaryNetwork1Ssid is also unavailable. In this way wireless network achieves simple redundancy through this technique." ::= { rcDot11NetworkParams 5} rcDot11NetworkRfChannel OBJECT-TYPE SYNTAX INTEGER (0..13) MAX-ACCESS read-write STATUS current DESCRIPTION "RF communication channel for the wireless interface. All devices in the same Basic Service Set ID (BSSID) must be communicating on the same channel in order to function correctly. Settings this object value to 0 allows the device to scan and choose the best available channel, while a channel number (1 to 13) allows to select a specific channel. Users are responsible for ensuring that the channel configuration complies with the regulatory standards." ::= { rcDot11NetworkParams 6} rcDot11NetworkSsidTxSuppress OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value of this object to 'true(1)' will suppress sending SSID information by Wireless Access Point(AP). Setting the value of this object to 'false(2)' will allow sending SSID information by AP. " ::= { rcDot11NetworkParams 7} rcDot11NetworkRfTxEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value of this object to 'true(1)' enables the RF transmitter of wireless interface. Setting the value of this object to 'false(2)' disables the RF transmitter." ::= { rcDot11NetworkParams 8 } rcDot11NetworkRate OBJECT-TYPE SYNTAX INTEGER { best(1), mbps1(2), mbps2(3), mbps11(4), mbps12(5), mbps18(6), mbps24(7), mbps36(8), mbps48(9), mbps54(10) } MAX-ACCESS read-write STATUS current DESCRIPTION "Data link rate (in Mbps) of the wireless interface. 'best(1)' - Choose the best data link rate for the interface. 'mbps1(2)' - 1 Mbps 'mbps2(3)' - 2 Mbps 'mbps11(4)' - 11 Mbps 'mbps12(5)' - 12 Mbps 'mbps18(6)' - 18 Mbps 'mbps24(7)' - 24 Mbps 'mbps36(8)' - 26 Mbps 'mbps48(9)' - 48 Mbps 'mbps54(10)' - 54 Mpbs." ::= { rcDot11NetworkParams 9 } rcDot11NetworkTxPower OBJECT-TYPE SYNTAX INTEGER (1..20) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum RF transmission power of the wireless interface." ::= { rcDot11NetworkParams 10 } rcDot11NetworkWdsEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "The Wireless Distribution System (WDS) support. WDS is simply a mechanism for constructing 802.11 frames using the 4-address format. Setting the value of this object to 'true(1)' enables WDS support. Setting the value of this object to 'false(2)' disbales this functionality. Note that this object must have a 'true(1)' value if rcDot11OpMode object value is 'ap(1)' to support station(s) with Client/Bridge functionality in the network." ::= { rcDot11NetworkParams 11} rcDot11NetworkWmmEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "The Wireless Multimedia Support (WMM) is, actually QoS support for the wireless interface. Setting the value of this object to 'true(1)' enables the QoS support. Setting this value of this object to 'false(2)' disables this functionality. Note the mapping in the presence of DS (DiffServ) field: DSCP 0x08 and 0x10 mapped to 'Background'. DSCP 0x20 and 0x28 mapped to 'Video'. DSCP 0x30 and 0x38 mapped to 'Voice'. All other DSCP(DiffServ Code Point) are mapped to 'Best Effort'." ::= { rcDot11NetworkParams 12} rcDot11NetworkTxShortPreamble OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value of this object to 'true(1)' allows sending short preamble block in the frames during wireless communication. Setting the value of this object to 'false(2)' lets the device communicate using long preamble. Note that the value of the object must be 'false(2)' when rcDot11NetworkPhyMode is set to 'dott11b(2)'." ::= { rcDot11NetworkParams 13} rcDot11NetworkDistance OBJECT-TYPE SYNTAX INTEGER (300..15000) MAX-ACCESS read-write STATUS current DESCRIPTION "The distance (in meters) between AP and the farthest station. It allows to optimize the wireless communication parameters, especially for running wireless links over long distances. Note that all WLAN devices on a network must have approximately the same distance parameters setting for optimal performance." ::= { rcDot11NetworkParams 14} rcDot11NetworkAssociatedStations OBJECT-TYPE SYNTAX Unsigned32 (0..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of connected station(s) in the wireless network." ::= { rcDot11NetworkParams 15} -- ---------------------------------------------------------------------- -- -- rcDot11SecurityParams objects -- ---------------------------------------------------------------------- -- rcDot11SecurityAuthMode OBJECT-TYPE SYNTAX INTEGER { none(1), wep(2), dot1x(3), wpa(4), wpaPsk(5), wpa2(6), wpa2psk(7), wpaAuto(8), wpaAutoPsk(9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Authentication mode to be used by the wireless interface in the network. 'none(1)' - No authentication. 'wep(2)' - WEP as an authentication algorithm 'dot1X(3)' - 802.1X based authentication with RADIUS client and server running on backend. 'wpa(4)' - WPAv1 authentication type (Enterprise). 'wpaPsk(5)' - WPAv1-PSK authentication type(Personal). 'wpa2(6)' - WPAv2 authentication type (Enterprise). 'wpa2Psk(7)' - WPAv2-PSK authentication type (Personal). 'wpaAuto(8)' - WPAv1 or WPAv2 authentication type (Enterprise). 'wpaAutoPsk(9)' - WPAv1 or WPAv2 authentication type (Personal). Note that for the object value of 'wep(2)' value of object rcDot11SecurityEncrypType must also be set to 'wep(2)'." ::= { rcDot11SecurityParams 1} rcDot11SecurityEncrypType OBJECT-TYPE SYNTAX INTEGER { auto(1), wep(2), tkip(3), aes(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Encryption algorithm to be used, in conjunction with the rcDot11SecurityAuthMode object. Note that with rcDot11OpMode object value set to 'clientBridge(2)' only 'none(0)', 'wpaPsk(5)' and 'wpa2Psk(7)' values are supported for this object. The value of 'aes(4)' is supported only when rcDot11SecurityAuthMode object value is set to 'wpa2(6)' or 'wpa2psk(7)'." ::= { rcDot11SecurityParams 2} rcDot11SecurityPassPhrase OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..48)) MAX-ACCESS read-write STATUS current DESCRIPTION "Security Pass Phrase to be used on the wireless network." ::= { rcDot11SecurityParams 3} rcDot11SecurityWepKey OBJECT-TYPE SYNTAX OCTET STRING (SIZE(10|26)) MAX-ACCESS read-write STATUS current DESCRIPTION "WEP key for the wireless network presented as an octet string containing ASCII presentation of hexadecimal digits. This key is applicaple only when rcDot11SecurityAuthMode object value is set to 'wep(2)'." ::= { rcDot11SecurityParams 4} rcDot11SecurityKeyRenewal OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Time (in hundredths of second) within which group key for the wireless network should be changed." ::= { rcDot11SecurityParams 5} rcDot11SecurityRadiusIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP Address of RADIUS server used by wireless interface for 802.1x based authentication." ::= { rcDot11SecurityParams 6} rcDot11SecurityRadiusPort OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The UDP port at which RADIUS server for the wireless interface is to be contacted." ::= { rcDot11SecurityParams 7} rcDot11SecurityRadiusSecret OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8..48)) MAX-ACCESS read-write STATUS current DESCRIPTION "The secret shared with the RADIUS server for 802.1x based authentication." ::= { rcDot11SecurityParams 8} -- ---------------------------------------------------------------------- -- -- rcDot11MacFiltering objects -- ---------------------------------------------------------------------- -- rcDot11MacFilteringControl OBJECT-TYPE SYNTAX INTEGER { open(1), allow(2), deny(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "MAC filtering policy in place for WLAN. 'open(1)' - No MAC filtering is performed, any MAC address is allowed to connect from the network. 'allow(2)' - Only allow MACs specified in rcDot11MacFilteringTable. 'deny(3)' - Only deny MACs specified in rcDot11MacFilteringTable." ::= { rcDot11MacFiltering 1} rcDot11MacFilteringTable OBJECT-TYPE SYNTAX SEQUENCE OF RcDot11MacFilteringEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides ability to configure wireless LAN MAC filtering entries. MACs represented by entries in this table are controlled per description of the object rcDot11MacFilteringControl." ::= { rcDot11MacFiltering 2 } rcDot11MacFilteringEntry OBJECT-TYPE SYNTAX RcDot11MacFilteringEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains one MAC address." INDEX { rcDot11FilterMacAddress } ::= { rcDot11MacFilteringTable 1 } RcDot11MacFilteringEntry ::= SEQUENCE { rcDot11FilterMacAddress MacAddress, rcDot11RowStatus INTEGER } rcDot11FilterMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MAC address from the network controled per description of the object rcDot11MacFilteringControl." ::= { rcDot11MacFilteringEntry 1 } rcDot11RowStatus OBJECT-TYPE SYNTAX INTEGER { active(1), createAndGo(4), delete(6) } MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this conceptual row. The syntax of this object represents restricted RowStatus functionality." REFERENCE "Description of RowStatus in SNMPv2-TC." ::= { rcDot11MacFilteringEntry 2 } -- ---------------------------------------------------------------------- -- -- rcDot11DhcpParams objects -- ---------------------------------------------------------------------- -- rcDot11DhcpServerEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value of this object to 'true(1)' enables the DHCP server functionality on wireless daughter card. Setting the value of this object to 'false(2)' disables the DHCP server functionality on the wireless daughter card." ::= { rcDot11DhcpParams 1} rcDot11DhcpStartOfPool OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Beginning of IP address pool in the DHCP server." ::= { rcDot11DhcpParams 2} rcDot11DhcpIpPoolSize OBJECT-TYPE SYNTAX INTEGER (1..64) MAX-ACCESS read-write STATUS current DESCRIPTION "Size of IP address pool in the DHCP server." ::= { rcDot11DhcpParams 3} rcDot11DhcpSubnet OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The subnet mask associated with the DHCP server. The value of the mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0. " ::= { rcDot11DhcpParams 4} rcDot11DhcpGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The default gateway to be used by DHCP server." ::= { rcDot11DhcpParams 5} rcDot11DhcpDnsIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of DNS server in the DHCP server." ::= { rcDot11DhcpParams 6} rcDot11DhcpLeaseTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Lease Time (in hundredths of second) to be used by DHCP server for the IpAddress assigned to other devices. Note that valid lease time varies between 6000 - 259200000." ::= { rcDot11DhcpParams 7} -- ---------------------------------------------------------------------- -- -- rcDot11AssociationInfo objects -- ---------------------------------------------------------------------- -- rcDot11AssociationTable OBJECT-TYPE SYNTAX SEQUENCE OF RcDot11AssociationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides detailed information on wireless links with associated stations if rcDot11OpMode object value is set to 'ap(1)'. If rcDot11OpMode object value is set to to 'clientBridge(2)' or 'clientIpBridge(3)' then this table reflects the link information to the associated AP." ::= { rcDot11AssociationInfo 1 } rcDot11AssociationEntry OBJECT-TYPE SYNTAX RcDot11AssociationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains one MAC address with its associated network settings on a wireless link." INDEX { rcDot11AssociationMac } ::= { rcDot11AssociationTable 1 } RcDot11AssociationEntry ::= SEQUENCE { rcDot11AssociationMac MacAddress, rcDot11AssociationChannel Unsigned32, rcDot11AssociationRate Unsigned32, rcDot11AssociationRssi Unsigned32, rcDot11AssociationTxSeq Unsigned32, rcDot11AssociationRxSeq Unsigned32, rcDot11AssociationSecurity OCTET STRING } rcDot11AssociationMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MAC address of associated station on a wireless link." ::= { rcDot11AssociationEntry 1 } rcDot11AssociationChannel OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The association channel in use for this wireless link." ::= { rcDot11AssociationEntry 2 } rcDot11AssociationRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current data rate for this wireless link." ::= { rcDot11AssociationEntry 3 } rcDot11AssociationRssi OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The RSSI(Received Signal Strength Indication) of the power present in a received RF signal for this wireless link." ::= { rcDot11AssociationEntry 4 } rcDot11AssociationTxSeq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Transmitter sequence number for associated station on this wireless link." ::= { rcDot11AssociationEntry 5 } rcDot11AssociationRxSeq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Receiver sequence number from the associated station on this wireless link." ::= { rcDot11AssociationEntry 6 } rcDot11AssociationSecurity OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The Security policy in place for this wireless link." ::= { rcDot11AssociationEntry 7 } -- ---------------------------------------------------------------------- -- -- Object Groups -- ---------------------------------------------------------------------- -- -- ---------------------------------------------------------------------- -- -- rcDot11Groups Interface objects -- ---------------------------------------------------------------------- -- rcDot11GlobalParamsGroup OBJECT-GROUP OBJECTS { rcDot11OpMode, rcDot11RFMAC, rcDot11IpAddress, rcDot11IpSubnet, rcDot11DefaultGateway, rcDot11Status, rcDot11UpTime, rcDot11Version, rcDot11TftpServerIpAddress, rcDot11SwUpgrade, rcDot11SwUpgradeStatus, rcDot11WlanReset } STATUS current DESCRIPTION "Objects related to global settings for wireless daughter card." ::= { rcDot11Groups 1 } rcDot11NetworkParamsGroup OBJECT-GROUP OBJECTS { rcDot11NetworkPhyMode, rcDot11NetworkDesiredSsid, rcDot11NetworkPrimarySsid, rcDot11NetworkSecondary1Ssid, rcDot11NetworkSecondary2Ssid, rcDot11NetworkRfChannel, rcDot11NetworkSsidTxSuppress, rcDot11NetworkAssociatedStations, rcDot11NetworkRfTxEnable, rcDot11NetworkRate, rcDot11NetworkTxPower, rcDot11NetworkWdsEnable, rcDot11NetworkWmmEnable, rcDot11NetworkTxShortPreamble, rcDot11NetworkDistance } STATUS current DESCRIPTION "Objects related to managing Network related settings on wireless daughter card." ::= { rcDot11Groups 2 } rcDot11SecurityParamsGroup OBJECT-GROUP OBJECTS { rcDot11SecurityAuthMode, rcDot11SecurityEncrypType , rcDot11SecurityPassPhrase, rcDot11SecurityWepKey, rcDot11SecurityKeyRenewal, rcDot11SecurityRadiusIpAddress, rcDot11SecurityRadiusPort, rcDot11SecurityRadiusSecret } STATUS current DESCRIPTION "Objects related to managing Security attributes on wireless daughter card." ::= { rcDot11Groups 3 } rcDot11DhcpParamsGroup OBJECT-GROUP OBJECTS { rcDot11DhcpServerEnable, rcDot11DhcpStartOfPool, rcDot11DhcpIpPoolSize, rcDot11DhcpSubnet, rcDot11DhcpGateway, rcDot11DhcpDnsIpAddress, rcDot11DhcpLeaseTime } STATUS current DESCRIPTION "Objects related to managing DHCP server on wirless daughter card." ::= { rcDot11Groups 4 } rcDot11MacFilteringTableGroup OBJECT-GROUP OBJECTS { rcDot11MacFilteringControl, rcDot11RowStatus } STATUS current DESCRIPTION "This group includes objects related to Mac Filter control." ::= { rcDot11Groups 5 } rcDot11AssociationTableGroup OBJECT-GROUP OBJECTS { rcDot11AssociationChannel, rcDot11AssociationRate, rcDot11AssociationRssi, rcDot11AssociationTxSeq, rcDot11AssociationRxSeq, rcDot11AssociationSecurity } STATUS current DESCRIPTION "Objects related to associated station(s) on their respective wireless link." ::= { rcDot11Groups 6 } END