RUGGEDCOM-DIGITAL-INPUTS-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI OBJECT-GROUP FROM SNMPv2-CONF TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC ruggedcomTraps FROM RUGGEDCOM-TRAPS-MIB ruggedcomMgmt FROM RUGGEDCOM-MIB; rcDigitalInputs MODULE-IDENTITY LAST-UPDATED "201411011000Z" -- Nov 1, 10:00 EST 2014 ORGANIZATION "RuggedCom" CONTACT-INFO "Postal: Siemens Canada Ltd 300 Applewood Crescent Concord, Ontario, L4K 5C7 Canada Tel: 1-905-856-5288 E-Mail: support@ruggedcom.com" DESCRIPTION "RuggedCom MIB for Managing Digital Inputs on RuggedCom Devices." REVISION "201411011000Z" -- Nov 1, 10:00 EST 2014 DESCRIPTION "The initial version of RuggedCom MIB for Managing Digital Inputs." ::= { ruggedcomMgmt 8 } -- ---------------------------------------------------------------------- -- -- Textual Conventions - To be moved to some common module -- ---------------------------------------------------------------------- -- -- Copied from P-BRIDGE-MIB to avoid compilation of that mib -- as ROS does not support P-BRIDGE-MIB EnabledStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A simple status value for the object." SYNTAX INTEGER { enabled(1), disabled(2) } RcLowOrHigh ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A state of signal." SYNTAX INTEGER { low(1), high(2) } RcActiveOrInactive ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Activity status." SYNTAX INTEGER { active(1), inactive(2) } -- ---------------------------------------------------------------------- -- rcDigitalInputsParams OBJECT IDENTIFIER ::= { rcDigitalInputs 1 } rcDigitalInputsConformance OBJECT IDENTIFIER ::= { rcDigitalInputs 2 } -- rcrcDigitalInputsCompliances OBJECT IDENTIFIER ::= { rcDigitalInputsConformance 1 } rcDigitalInputsGroups OBJECT IDENTIFIER ::= { rcDigitalInputsConformance 2 } -- ---------------------------------------------------------------------- -- -- ---------------------------------------------------------------------- -- -- Digital Inputs configuration and status -- ---------------------------------------------------------------------- -- rcDigitalInputsTable OBJECT-TYPE SYNTAX SEQUENCE OF RcDigitalInputsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Digital Iputs table entries." ::= { rcDigitalInputsParams 1 } rcDigitalInputsEntry OBJECT-TYPE SYNTAX RcDigitalInputsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration and status parameters for a Digital Input." INDEX { rcDiID } ::= { rcDigitalInputsTable 1 } RcDigitalInputsEntry ::= SEQUENCE { rcDiID Integer32, rcDiAlarm EnabledStatus, rcDiActiveState INTEGER, rcDiDelayOn Integer32, rcDiDelayOff Integer32, rcDiDescription DisplayString, rcDiInputState RcLowOrHigh, rcDiAlarmStatus RcActiveOrInactive } rcDiID OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The physical Digital Input ID of the device for which this Entry contains configuration settings." ::= { rcDigitalInputsEntry 1 } rcDiAlarm OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or disable alarm for this sigital input." ::= { rcDigitalInputsEntry 2 } rcDiActiveState OBJECT-TYPE SYNTAX RcLowOrHigh MAX-ACCESS read-write STATUS current DESCRIPTION "A state that would activate alarm for this digital input." ::= { rcDigitalInputsEntry 3 } rcDiDelayOn OBJECT-TYPE SYNTAX Integer32(0 | 10..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "A time for which the input must be active before the alarm is activated." ::= { rcDigitalInputsEntry 4 } rcDiDelayOff OBJECT-TYPE SYNTAX Integer32(0 | 10..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "A time for which the input must be inactive before the alarm is deactivated." ::= { rcDigitalInputsEntry 5 } rcDiDescription OBJECT-TYPE SYNTAX DisplayString (SIZE(0..24)) MAX-ACCESS read-write STATUS current DESCRIPTION "Current digital input state read from hardware." ::= { rcDigitalInputsEntry 6 } rcDiInputState OBJECT-TYPE SYNTAX RcLowOrHigh MAX-ACCESS read-only STATUS current DESCRIPTION "Current digital input state read from hardware." ::= { rcDigitalInputsEntry 7 } rcDiAlarmStatus OBJECT-TYPE SYNTAX RcActiveOrInactive MAX-ACCESS read-only STATUS current DESCRIPTION "Current alarm status for this digital input. Change of the value of this object will result in sending notification (trap) digitalInputTrap." ::= { rcDigitalInputsEntry 8 } -- ---------------------------------------------------------------------- -- -- Definition of boot version mismatch trap -- ---------------------------------------------------------------------- -- digitalInputTrap NOTIFICATION-TYPE OBJECTS { rcDiID, rcDiDescription, rcDiAlarmStatus } STATUS current DESCRIPTION "Indication that state of digital input changed to the state indicated by the value of object rcDiAlarmState." ::= { ruggedcomTraps 18 } -- ---------------------------------------------------------------------- -- -- Conformance Groups -- ---------------------------------------------------------------------- -- rcDigitalInputsTableGroup OBJECT-GROUP OBJECTS { rcDiID, rcDiAlarm, rcDiActiveState, rcDiDelayOn, rcDiDelayOff, rcDiDescription, rcDiInputState, rcDiAlarmStatus } STATUS current DESCRIPTION "Group objects related to Digital Alarms configuration and status." ::= { rcDigitalInputsGroups 1 } rcDigitalInputsNotifyGroup OBJECT-GROUP OBJECTS { rcRstpNewTopology } STATUS current DESCRIPTION "A group of objects that define New Topology trap." ::= { rcDigitalInputsGroups 2 } END