SDS-MACRO-ST-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32, Gauge32, TimeTicks, IpAddress, enterprises FROM SNMPv2-SMI; mib-AN-Dcz-SDS MODULE-IDENTITY LAST-UPDATED "202010282122Z" ORGANIZATION "AN-D.cz" CONTACT-INFO " Adam Nemcek AN-D.cz - - CZ EUROPE - adam.nemcek@an-d.cz" DESCRIPTION "The MIB module to describe generic objects for AN-D.cz device - SDS MACRO ST." REVISION "202010280000Z" DESCRIPTION " First revision. By AN." ::= { enterprises 33283 } -- -- MIB file definition for SDS - MACRO ST -- sdsxpublic OBJECT IDENTIFIER ::= { mib-AN-Dcz-SDS 1 } sdsMACROST OBJECT IDENTIFIER ::= { sdsxpublic 55 } -- **************************************************************************** sdsIPWatchdog OBJECT IDENTIFIER ::= { sdsMACROST 1 } ipwActive OBJECT-TYPE SYNTAX INTEGER { disabled(0), active(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current IP watchdog status." ::= { sdsIPWatchdog 1 } ipwPingIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of the wdg-monitored object." ::= { sdsIPWatchdog 2 } ipwPauseAfterPwOn OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Amount of time in [sec]. Duration of the IP watchdog disable period, applied when watchdog device itself is first powered on." ::= { sdsIPWatchdog 3 } ipwPingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Config value - the RTT timeout." ::= { sdsIPWatchdog 4 } ipwRepeatPingPer OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "PING REQUEST packet sending: the configured send repeat period, in [miliseconds]." ::= { sdsIPWatchdog 5 } ipwIgnoreLostCnt OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "How many lost PING REPLY packets should get ignored, before activating the relay." ::= { sdsIPWatchdog 6 } ipwPauseWdAfterAct OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Delay of the IP watchdog pause, applied when the output relay is activated (e.g. the time for controlled device recovery)." ::= { sdsIPWatchdog 7 } ipwRelayActTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "How many [seconds] should be the output relay activated." ::= { sdsIPWatchdog 8 } ipwActualFailed OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "How many unreceived PING REPLY packets are detected so far." ::= { sdsIPWatchdog 9 } ipwLastRTT OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Round Trip Time for the last ping echo." ::= { sdsIPWatchdog 10 } ipwActualRelayState OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual (virtual) output relay status (before mapping this status to the selected hardware)." ::= { sdsIPWatchdog 11 } -- **************************************************************************** sdsOptoInput OBJECT IDENTIFIER ::= { sdsMACROST 2 } opto1 OBJECT-TYPE SYNTAX INTEGER { activeSignalPresent(0), noSignal(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current OPTO1 binary input status." ::= { sdsOptoInput 1 } opto2 OBJECT-TYPE SYNTAX INTEGER { activeSignalPresent(0), noSignal(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current OPTO2 binary input status." ::= { sdsOptoInput 2 } opto3 OBJECT-TYPE SYNTAX INTEGER { activeSignalPresent(0), noSignal(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current OPTO3 binary input status." ::= { sdsOptoInput 3 } opto4 OBJECT-TYPE SYNTAX INTEGER { activeSignalPresent(0), noSignal(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current OPTO4 binary input status." ::= { sdsOptoInput 4 } opto5 OBJECT-TYPE SYNTAX INTEGER { activeSignalPresent(0), noSignal(128) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current OPTO5 binary input status." ::= { sdsOptoInput 5 } opto6 OBJECT-TYPE SYNTAX INTEGER { activeSignalPresent(0), noSignal(64) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current OPTO6 binary input status." ::= { sdsOptoInput 6 } opto7 OBJECT-TYPE SYNTAX INTEGER { activeSignalPresent(0), noSignal(32) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current OPTO7 binary input status." ::= { sdsOptoInput 7 } opto8 OBJECT-TYPE SYNTAX INTEGER { activeSignalPresent(0), noSignal(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current OPTO8 binary input status." ::= { sdsOptoInput 8 } logics0input OBJECT-TYPE SYNTAX INTEGER { activeSignalPresent(0), noSignal(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current LOGIC-S0 binary input status." ::= { sdsOptoInput 9 } -- **************************************************************************** sdsOutputRelay OBJECT IDENTIFIER ::= { sdsMACROST 3 } sdsRE1state OBJECT-TYPE SYNTAX INTEGER { off(0), activated(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Current RELAY 1 output status." ::= { sdsOutputRelay 1 } sdsRE1cby OBJECT-TYPE SYNTAX INTEGER { manualControl(0), sdscControl(2), ipwControl(4), oneShotReset(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "RELAY 1 controled by ..." ::= { sdsOutputRelay 2 } sdsRE1name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User name for RELAY 1." ::= { sdsOutputRelay 3 } sdsRE2state OBJECT-TYPE SYNTAX INTEGER { off(0), activated(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Current RELAY 2 output status." ::= { sdsOutputRelay 4 } sdsRE2cby OBJECT-TYPE SYNTAX INTEGER { manualControl(0), sdscControl(2), ipwControl(4), oneShotReset(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "RELAY 2 controled by ..." ::= { sdsOutputRelay 5 } sdsRE2name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User name for RELAY 2." ::= { sdsOutputRelay 6 } sdsRE3state OBJECT-TYPE SYNTAX INTEGER { off(0), activated(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Current RELAY 3 output status." ::= { sdsOutputRelay 7 } sdsRE3cby OBJECT-TYPE SYNTAX INTEGER { manualControl(0), sdscControl(2), ipwControl(4), oneShotReset(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "RELAY 3 controled by ..." ::= { sdsOutputRelay 8 } sdsRE3name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User name for RELAY 3." ::= { sdsOutputRelay 9 } sdsRE4state OBJECT-TYPE SYNTAX INTEGER { off(0), activated(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Current RELAY 4 output status." ::= { sdsOutputRelay 10 } sdsRE4cby OBJECT-TYPE SYNTAX INTEGER { manualControl(0), sdscControl(2), ipwControl(4), oneShotReset(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "RELAY 4 controled by ..." ::= { sdsOutputRelay 11 } sdsRE4name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User name for RELAY 4." ::= { sdsOutputRelay 12 } sdsRE5state OBJECT-TYPE SYNTAX INTEGER { off(0), activated(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Current RELAY 5 output status." ::= { sdsOutputRelay 13 } sdsRE5cby OBJECT-TYPE SYNTAX INTEGER { manualControl(0), sdscControl(2), ipwControl(4), oneShotReset(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "RELAY 5 controled by ..." ::= { sdsOutputRelay 14 } sdsRE5name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User name for RELAY 5." ::= { sdsOutputRelay 15 } sdsRE6state OBJECT-TYPE SYNTAX INTEGER { off(0), activated(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Current RELAY 6 output status." ::= { sdsOutputRelay 16 } sdsRE6cby OBJECT-TYPE SYNTAX INTEGER { manualControl(0), sdscControl(2), ipwControl(4), oneShotReset(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "RELAY 6 controled by ..." ::= { sdsOutputRelay 17 } sdsRE6name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User name for RELAY 6." ::= { sdsOutputRelay 18 } -- **************************************************************************** sdsPWMoutput OBJECT IDENTIFIER ::= { sdsMACROST 4 } sdsPWM1p2freq OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Actual (PWM 1 and PWM2) generator frequency [Hz]." ::= { sdsPWMoutput 1 } sdsPWM1duty OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Actual PWM1 duty control setting 0 - 100 [percent]." ::= { sdsPWMoutput 2 } -- { sdsPWMoutput 3 } is RESERVED sdsPWM2duty OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Actual PWM2 duty control setting 0 - 100 [percent]." ::= { sdsPWMoutput 4 } sdsPWM3p4freq OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Actual (PWM 3 and PWM4) generator frequency [Hz]." ::= { sdsPWMoutput 5 } sdsPWM3duty OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Actual PWM3 duty control setting 0 - 100 [percent]." ::= { sdsPWMoutput 6 } -- { sdsPWMoutput 7 } is RESERVED sdsPWM4duty OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Actual PWM4 duty control setting 0 - 100 [percent]." ::= { sdsPWMoutput 8 } -- **************************************************************************** -- the ADC input items sdsADCinputs OBJECT IDENTIFIER ::= { sdsMACROST 5 } sdsADCrawValue1 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual analog AD1 input value [raw value 0..4095]." ::= { sdsADCinputs 1 } sdsADCtext1 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "SI textual value for AD1 input (conversion result)." ::= { sdsADCinputs 5 } sdsADCunit1 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User unit for AD1 input." ::= { sdsADCinputs 13 } sdsADCname1 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User name for AD1 input." ::= { sdsADCinputs 9 } sdsADCrawValue2 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual analog AD2 input value [raw value 0..4095]." ::= { sdsADCinputs 2 } sdsADCtext2 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "SI textual value for AD2 input (conversion result)." ::= { sdsADCinputs 6 } sdsADCunit2 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User unit for AD2 input." ::= { sdsADCinputs 14 } sdsADCname2 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User name for AD2 input." ::= { sdsADCinputs 10 } sdsADCrawValue3 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual analog AD3 input value [raw value 0..4095]." ::= { sdsADCinputs 3 } sdsADCtext3 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "SI textual value for AD3 input (conversion result)." ::= { sdsADCinputs 7 } sdsADCunit3 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User unit for AD3 input." ::= { sdsADCinputs 15 } sdsADCname3 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User name for AD3 input." ::= { sdsADCinputs 11 } sdsADCrawValue4 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual analog AD4 input value [raw value 0..4095]." ::= { sdsADCinputs 4 } sdsADCtext4 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "SI textual value for AD4 input (conversion result)." ::= { sdsADCinputs 8 } sdsADCunit4 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User unit for AD4 input." ::= { sdsADCinputs 16 } sdsADCname4 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User name for AD4 input." ::= { sdsADCinputs 12 } -- **************************************************************************** -- the ONEWIRE table (MACRO-ST: both BUS A and BUS B in a single table) -- The ONEWIRE table contains information on the OneWire devices (like DS18B20 or SDS-T-RH) sdsONEWIRETable OBJECT-TYPE SYNTAX SEQUENCE OF SdsONEWIREEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of all (1-Wire) devices." ::= { sdsMACROST 6 } sdsONEWIREEntry OBJECT-TYPE SYNTAX SdsONEWIREEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular ONEWIRE device." INDEX { sdsONEWIREtableRowIndex } ::= { sdsONEWIRETable 1 } SdsONEWIREEntry ::= SEQUENCE { sdsONEWIREdeviceROMcode OCTET STRING, sdsONEWIREactualTempInteger Integer32, sdsONEWIREactualTempFrac Integer32, sdsONEWIREuserName OCTET STRING, sdsONEWIREactualTempCompleteMul100 Integer32, sdsONEWIREtableRowIndex Integer32, sdsONEWIREactualRHpercent Integer32 } sdsONEWIREdeviceROMcode OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Internal ONEWIRE device ROM unique identification code." ::= { sdsONEWIREEntry 1 } sdsONEWIREactualTempInteger OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual temperature for this ONEWIRE sensor, an integral part." ::= { sdsONEWIREEntry 2 } sdsONEWIREactualTempFrac OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual temperature for this ONEWIRE sensor, a fractional part." ::= { sdsONEWIREEntry 3 } sdsONEWIREuserName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User name for the actual ONEWIRE device." ::= { sdsONEWIREEntry 4 } sdsONEWIREactualTempCompleteMul100 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual temperature for this ONEWIRE sensor: the complete value multiplied by 100 (target precision: two post-zero digits)." ::= { sdsONEWIREEntry 5 } sdsONEWIREtableRowIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "ONEWIRE device index in this table." ::= { sdsONEWIREEntry 6 } sdsONEWIREactualRHpercent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual RH value for this ONEWIRE sensor" ::= { sdsONEWIREEntry 7 } -- **************************************************************************** sdsVersionEntry OBJECT IDENTIFIER ::= { sdsMACROST 7 } sdsVersionText OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "SDS device version text." ::= { sdsVersionEntry 1 } sdsCustomTrap1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SDS-C custom int32 TRAP." ::= { sdsVersionEntry 2 } -- **************************************************************************** sdsGeneralInfoEntry OBJECT IDENTIFIER ::= { sdsMACROST 8 } sdsNTPvalue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual NTP UTC time value (SDS device is NTP client)." ::= { sdsGeneralInfoEntry 1 } sdsSoCtempValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual SoC chip internal temperature, represented in a special units [0..4095]. This needs to be recalculated to get a degC value." ::= { sdsGeneralInfoEntry 2 } sdsOneWireBUSAcountValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of discovered 1-Wire devices on BUS A." ::= { sdsGeneralInfoEntry 3 } sdsOneWireBUSBcountValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of discovered 1-Wire devices on BUS B." ::= { sdsGeneralInfoEntry 4 } sdsPDgpioState OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "PD0 + PD1 + TOPB actual port-pin bit (log1/log0) status." ::= { sdsGeneralInfoEntry 5 } sdsPDgpioDirection OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "PD0 + PD1 + TOPB actual port-pin direction (in/out) status." ::= { sdsGeneralInfoEntry 6 } sdsBackUpCoinBatteryVoltageValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual voltage reading of the back-up coin battery, represented as raw ADC value [0..4095]. This needs to be recalculated to get a value in Volts." ::= { sdsGeneralInfoEntry 7 } sdsLOCALTIMEvalue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual LOCAL time value (SDS device is NTP client)." ::= { sdsGeneralInfoEntry 10 } -- **************************************************************************** -- the S0 INPUT table -- The S0 INPUT contains information from the S0 impulse input sdsS0Table OBJECT-TYPE SYNTAX SEQUENCE OF SdsS0Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of S0 impulse inputs." ::= { sdsMACROST 9 } sdsS0Entry OBJECT-TYPE SYNTAX SdsS0Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular S0 input." INDEX { sdsS0tableRowIndex } ::= { sdsS0Table 1 } SdsS0Entry ::= SEQUENCE { sdsS0impCountT0 Counter32, sdsS0impCountT1 Counter32, sdsS0impMoneyOffsetT0 Gauge32, sdsS0impMoneyOffsetT1 Gauge32, sdsS0constant Gauge32, sdsS0translatedUnitT0 OCTET STRING, sdsS0translatedUnitT1 OCTET STRING, sdsS0translatedCashT0 OCTET STRING, sdsS0translatedCashT1 OCTET STRING, sdsS0actualEnergyFlow OCTET STRING, sdsS0constantMTD Gauge32, sdsS0tableRowIndex Integer32 } sdsS0impCountT0 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual S0 impulse counter value for the tarif state T0 (no tarif signal)." ::= { sdsS0Entry 1 } sdsS0impCountT1 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual S0 impulse counter value for the tarif state T1 (active tarif signal)." ::= { sdsS0Entry 2 } sdsS0impMoneyOffsetT0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Offset (impulse count) for cash calculation. Cash value is calculated relatively starting at this offset, for the T0 counter." ::= { sdsS0Entry 3 } sdsS0impMoneyOffsetT1 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Offset (impulse count) for cash calculation. Cash value is calculated relatively starting at this offset, for the T1 counter." ::= { sdsS0Entry 4 } sdsS0constant OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "S0 output constant (number of impulses for 1 energy unit)." ::= { sdsS0Entry 5 } sdsS0translatedUnitT0 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "T0 related S0 impulse count value, recalculated into energy units, in a textual representation." ::= { sdsS0Entry 6 } sdsS0translatedUnitT1 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "T1 related S0 impulse count value, recalculated into energy units, in a textual representation." ::= { sdsS0Entry 7 } sdsS0translatedCashT0 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "T0 related S0 counter value recalculated into cash (total T0 impulse count minus a T0 custom offset), in a textual representation." ::= { sdsS0Entry 8 } sdsS0translatedCashT1 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "T1 related S0 counter value recalculated into cash (total T1 impulse count minus a T1 custom offset), in a textual representation." ::= { sdsS0Entry 9 } sdsS0actualEnergyFlow OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "S0: the actual energy flow value." ::= { sdsS0Entry 10 } sdsS0constantMTD OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "S0 MTD constant." ::= { sdsS0Entry 11 } sdsS0tableRowIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "S0 table row index." ::= { sdsS0Entry 12 } -- **************************************************************************** -- the SDSCEP table -- The SDSCEP contains values from SDS-C sys[140] to sys[147] (user data) sdsSDSCEPTable OBJECT-TYPE SYNTAX SEQUENCE OF SdsSDSCEPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of SDS-C SDSCEP user values. Equals to sys[140] thru sys[147]." ::= { sdsMACROST 10 } sdsSDSCEPEntry OBJECT-TYPE SYNTAX SdsSDSCEPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing the values for SDS-C SDSCEP items." INDEX { sdsSDSCEPtableRowIndex } ::= { sdsSDSCEPTable 1 } SdsSDSCEPEntry ::= SEQUENCE { sdsSDSCEPvalue Integer32, sdsSDSCEPtableRowIndex Integer32 } sdsSDSCEPvalue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Actual value for the particular SDS-C SDSCEP value. First index is starting at sys[140]." ::= { sdsSDSCEPEntry 1 } sdsSDSCEPtableRowIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the particular SDS-C SDSCEP value. Add a number of 139 to this item value, to get the exact sys[] location. Example: value == 1 -> sys[140]." ::= { sdsSDSCEPEntry 2 } -- **************************************************************************** sdsCOMxEntry OBJECT IDENTIFIER ::= { sdsMACROST 11 } sdsETStelnetConnected_COM1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Is there any Ethernet client connected and using the Eth-to-Serial(COM1) converter, at this moment." ::= { sdsCOMxEntry 1 } sdsETSbaudrate_COM1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "COM1: Actual configured UART baud rate in [bps]." ::= { sdsCOMxEntry 2 } sdsETSdataSize_COM1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "COM1: Actual configured UART char data size [number of bits per char]." ::= { sdsCOMxEntry 3 } sdsETSstopBits_COM1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "COM1: Actual configured UART number of stop bits [0, 1 or 2 stop bits]" ::= { sdsCOMxEntry 4 } sdsETSparity_COM1 OBJECT-TYPE SYNTAX INTEGER { noParity(1), oddParity(2), evenParity(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "COM1: Actual configured UART parity." ::= { sdsCOMxEntry 5 } sdsETSuartInBytes_COM1 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "COM1: Total number of UART IN bytes." ::= { sdsCOMxEntry 6 } sdsETSuartOutBytes_COM1 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "COM1: Total number of UART OUT bytes." ::= { sdsCOMxEntry 7 } sdsCOM6baudrate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "COM6: Actual configured UART baud rate in [bps]." ::= { sdsCOMxEntry 9 } sdsCOM6dataSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "COM6: Actual configured UART char data size [number of bits per char]." ::= { sdsCOMxEntry 10 } sdsCOM6stopBits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "COM6: Actual configured UART number of stop bits [0, 1 or 2 stop bits]" ::= { sdsCOMxEntry 11 } sdsCOM6parity OBJECT-TYPE SYNTAX INTEGER { noParity(1), oddParity(2), evenParity(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "COM6: Actual configured UART parity." ::= { sdsCOMxEntry 12 } sdsCOM6uartInBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "COM6: Total number of UART IN bytes." ::= { sdsCOMxEntry 13 } sdsCOM6uartOutBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "COM6: Total number of UART OUT bytes." ::= { sdsCOMxEntry 14 } -- **************************************************************************** -- **************************************************************************** -- TRAP-SDS-MACROST-MIB DEFINITIONS -- **************************************************************************** ipwActive-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { ipwActive } DESCRIPTION "TRAP: The current IP watchdog status." ::= 70 ipwPingIP-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { ipwPingIP } DESCRIPTION "TRAP: IP address of the wdg monitored object." ::= 71 ipwPauseAfterPwOn-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { ipwPauseAfterPwOn } DESCRIPTION "TRAP: Duration of the IP watchdog disable period." ::= 72 ipwPingTimeout-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { ipwPingTimeout } DESCRIPTION "TRAP: IP watchdog RTT timeout." ::= 73 ipwRepeatPingPer-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { ipwRepeatPingPer } DESCRIPTION "TRAP: IP watchdog send repeat period." ::= 74 ipwIgnoreLostCnt-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { ipwIgnoreLostCnt } DESCRIPTION "TRAP: IP watchdog: number of missing packets to ignore." ::= 75 ipwPauseWdAfterAct-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { ipwPauseWdAfterAct } DESCRIPTION "TRAP: IP watchog pause applied after output activation." ::= 76 ipwRelayActTime-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { ipwRelayActTime } DESCRIPTION "TRAP: Length of IP watchdog notification output active state." ::= 77 ipwActualFailed-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { ipwActualFailed } DESCRIPTION "TRAP: number of missing IP watchdog ping responses." ::= 78 ipwLastRTT-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { ipwLastRTT } DESCRIPTION "TRAP: IP watchdog Round Trip Time for the last ping echo." ::= 79 ipwActualRelayState-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { ipwActualRelayState } DESCRIPTION "TRAP: Actual (virtual) output relay status of IP watchdog." ::= 80 -- next opto1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { opto1 } DESCRIPTION "TRAP: optical input 1 status." ::= 100 opto2-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { opto2 } DESCRIPTION "TRAP: optical input 2 status." ::= 101 opto3-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { opto3 } DESCRIPTION "TRAP: optical input 3 status." ::= 102 opto4-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { opto4 } DESCRIPTION "TRAP: optical input 4 status." ::= 103 opto5-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { opto5 } DESCRIPTION "TRAP: optical input 5 status." ::= 104 opto6-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { opto6 } DESCRIPTION "TRAP: optical input 6 status." ::= 105 opto7-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { opto7 } DESCRIPTION "TRAP: optical input 7 status." ::= 106 opto8-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { opto8 } DESCRIPTION "TRAP: optical input 8 status." ::= 107 logics0input-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { logics0input } DESCRIPTION "TRAP: LOGIC-S0 input status." ::= 108 -- next sdsRE1state-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE1state } DESCRIPTION "TRAP: Current RELAY 1 output status." ::= 150 sdsRE1cby-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE1cby } DESCRIPTION "TRAP: RELAY 1 controled by ..." ::= 151 sdsRE1name-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE1name } DESCRIPTION "TRAP: User name for RELAY 1." ::= 152 sdsRE2state-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE2state } DESCRIPTION "TRAP: Current RELAY 2 output status." ::= 153 sdsRE2cby-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE2cby } DESCRIPTION "TRAP: RELAY 2 controled by ..." ::= 154 sdsRE2name-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE2name } DESCRIPTION "TRAP: User name for RELAY 2." ::= 155 sdsRE3state-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE3state } DESCRIPTION "TRAP: Current RELAY 3 output status." ::= 156 sdsRE3cby-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE3cby } DESCRIPTION "TRAP: RELAY 3 controled by ..." ::= 157 sdsRE3name-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE3name } DESCRIPTION "TRAP: User name for RELAY 3." ::= 158 sdsRE4state-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE4state } DESCRIPTION "TRAP: Current RELAY 4 output status." ::= 159 sdsRE4cby-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE4cby } DESCRIPTION "TRAP: RELAY 4 controled by ..." ::= 160 sdsRE4name-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE4name } DESCRIPTION "TRAP: User name for RELAY 4." ::= 161 sdsRE5state-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE5state } DESCRIPTION "TRAP: Current RELAY 5 output status." ::= 162 sdsRE5cby-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE5cby } DESCRIPTION "TRAP: RELAY 5 controled by ..." ::= 163 sdsRE5name-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE5name } DESCRIPTION "TRAP: User name for RELAY 5." ::= 164 sdsRE6state-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE6state } DESCRIPTION "TRAP: Current RELAY 6 output status." ::= 165 sdsRE6cby-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE6cby } DESCRIPTION "TRAP: RELAY 6 controled by ..." ::= 166 sdsRE6name-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsRE6name } DESCRIPTION "TRAP: User name for RELAY 6." ::= 167 -- next sdsPWM1p2freq-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsPWM1p2freq } DESCRIPTION "TRAP: Actual (PWM1 and PWM2) generator frequency [Hz]." ::= 200 sdsPWM1duty-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsPWM1duty } DESCRIPTION "TRAP: Actual PWM1 duty control setting." ::= 201 sdsPWM2duty-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsPWM1duty } DESCRIPTION "TRAP: Actual PWM2 duty control setting." ::= 203 sdsPWM3p4freq-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsPWM3p4freq } DESCRIPTION "TRAP: Actual (PWM3 and PWM4) generator frequency [Hz]." ::= 204 sdsPWM3duty-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsPWM3duty } DESCRIPTION "TRAP: Actual PWM3 duty control setting." ::= 205 sdsPWM4duty-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsPWM4duty } DESCRIPTION "TRAP: Actual PWM4 duty control setting." ::= 207 -- next sdsADCrawValue1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCrawValue1 } DESCRIPTION "TRAP: Actual AD1 input value [raw]." ::= 250 sdsADCtext1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCtext1 } DESCRIPTION "TRAP: Textual conversion output for AD1 input." ::= 254 sdsADCunit1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCunit1 } DESCRIPTION "TRAP: User unit for AD1 input." ::= 262 sdsADCname1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCname1 } DESCRIPTION "TRAP: User name for AD1 input." ::= 258 sdsADCrawValue2-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCrawValue2 } DESCRIPTION "TRAP: Actual AD2 input value [raw]." ::= 251 sdsADCtext2-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCtext2 } DESCRIPTION "TRAP: Textual conversion output for AD2 input." ::= 255 sdsADCunit2-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCunit2 } DESCRIPTION "TRAP: User unit for AD2 input." ::= 263 sdsADCname2-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCname2 } DESCRIPTION "TRAP: User name for AD2 input." ::= 259 sdsADCrawValue3-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCrawValue3 } DESCRIPTION "TRAP: Actual AD3 input value [raw]." ::= 252 sdsADCtext3-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCtext3 } DESCRIPTION "TRAP: Textual conversion output for AD3 input." ::= 256 sdsADCunit3-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCunit3 } DESCRIPTION "TRAP: User unit for AD3 input." ::= 264 sdsADCname3-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCname3 } DESCRIPTION "TRAP: User name for AD3 input." ::= 260 sdsADCrawValue4-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCrawValue3 } DESCRIPTION "TRAP: Actual AD4 input value [raw]." ::= 253 sdsADCtext4-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCtext4 } DESCRIPTION "TRAP: Textual conversion output for AD4 input." ::= 257 sdsADCunit4-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCunit4 } DESCRIPTION "TRAP: User unit for AD4 input." ::= 265 sdsADCname4-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsADCname4 } DESCRIPTION "TRAP: User name for AD4 input." ::= 261 -- next sdsONEWIREactualTempInteger-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsONEWIREactualTempInteger } DESCRIPTION "TRAP: Actual temperature [integral part] for this DS18B20 sensor. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 300 sdsONEWIREactualTempFrac-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsONEWIREactualTempFrac } DESCRIPTION "TRAP: Actual temperature [a fractional part] for this DS18B20 sensor. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 301 sdsONEWIREdeviceROMcode-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsONEWIREdeviceROMcode } DESCRIPTION "TRAP: DS18B20 device ROM code. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 302 sdsONEWIREuserName-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsONEWIREuserName } DESCRIPTION "TRAP: User name for this DS18B20 device. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 303 sdsONEWIREactualTempCompleteMul100-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsONEWIREactualTempCompleteMul100 } DESCRIPTION "TRAP: Actual temperature [a complete value, multiplied by 100]. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 304 sdsONEWIREactualRHpercent-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsONEWIREactualRHpercent } DESCRIPTION "TRAP: Actual RH value for SDS-T-RH sensor on this position. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 306 -- next sdsVersionText-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsVersionText } DESCRIPTION "TRAP: SDS device version text." ::= 400 sdsCustomTrap1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsCustomTrap1 } DESCRIPTION "TRAP: SDS-C custom int32 trap." ::= 401 -- next sdsNTPvalue-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsNTPvalue } DESCRIPTION "TRAP: Actual NTP UTC time value (SDS device is NTP client)." ::= 600 sdsSoCtempValue-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsSoCtempValue } DESCRIPTION "TRAP: Actual SoC chip internal temperature, in special units." ::= 601 sdsOneWireBUSAcountValue-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsOneWireBUSAcountValue } DESCRIPTION "TRAP: Number of discovered 1-Wire devices on BUS A." ::= 602 sdsOneWireBUSBcountValue-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsOneWireBUSBcountValue } DESCRIPTION "TRAP: Number of discovered 1-Wire devices on BUS B." ::= 603 sdsPDgpioState-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsPDgpioState } DESCRIPTION "TRAP: actual port-pin bit (log1/log0) status." ::= 604 sdsPDgpioDirection-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsPDgpioDirection } DESCRIPTION "TRAP: actual port-pin direction (in/out) status." ::= 605 sdsBackUpCoinBatteryVoltageValue-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsBackUpCoinBatteryVoltageValue } DESCRIPTION "TRAP: Actual voltage reading of the back-up coin battery, raw ADC value." ::= 606 sdsLOCALTIMEvalue-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsLOCALTIMEvalue } DESCRIPTION "TRAP: Actual LOCAL time value (SDS device is NTP client)." ::= 610 -- next sdsS0impCountT0-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsS0impCountT0 } DESCRIPTION "TRAP: Actual S0 impulse counter value for T0 tarif. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 501 sdsS0impCountT1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsS0impCountT1 } DESCRIPTION "TRAP: Actual S0 impulse counter value for T1 tarif. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 502 sdsS0impMoneyOffsetT0-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsS0impMoneyOffsetT0 } DESCRIPTION "TRAP: Offset (impulse count) for cash calculation for T0. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 503 sdsS0impMoneyOffsetT1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsS0impMoneyOffsetT1 } DESCRIPTION "TRAP: Offset (impulse count) for cash calculation for T1. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 504 sdsS0constant-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsS0constant } DESCRIPTION "TRAP: S0 output constant (number of impulses for 1 energy unit). INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 505 sdsS0translatedUnitT0-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsS0translatedUnitT0 } DESCRIPTION "TRAP: T0 related S0 impulse count value as textual energy unit. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 506 sdsS0translatedUnitT1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsS0translatedUnitT1 } DESCRIPTION "TRAP: T1 related S0 impulse count value as textual energy unit. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 507 sdsS0translatedCashT0-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsS0translatedCashT0 } DESCRIPTION "TRAP: T0 related S0 counter value as textual cash value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 508 sdsS0translatedCashT1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsS0translatedCashT1 } DESCRIPTION "TRAP: T1 related S0 counter value as textual cash value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 509 sdsS0actualEnergyFlow-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsS0actualEnergyFlow } DESCRIPTION "TRAP: S0: the actual energy flow value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 510 sdsS0constantMTD-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsS0constantMTD } DESCRIPTION "TRAP: Actual MTD constat configuration value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 511 -- next sdsSDSCEPvalue-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsSDSCEPvalue } DESCRIPTION "TRAP: Actual value for the particular SDS-C SDSCEP value. INFO: USE INDEX OID TO ACCESS THE TABLE ITEMS." ::= 700 -- next sdsETStelnetConnected_COM1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsETStelnetConnected_COM1 } DESCRIPTION "TRAP: Is any Ethernet client connected to Eth-to-Serial COM1 converter." ::= 800 sdsETSbaudrate_COM1trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsETSbaudrate_COM1 } DESCRIPTION "TRAP: COM1 actual configured UART baud rate in [bps]." ::= 801 sdsETSdataSize_COM1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsETSdataSize_COM1 } DESCRIPTION "TRAP: COM1 actual configured UART char data size [num of bits]." ::= 802 sdsETSstopBits_COM1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsETSstopBits_COM1 } DESCRIPTION "TRAP: COM1 actual configured UART number of stop bits." ::= 803 sdsETSparity_COM1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsETSparity_COM1 } DESCRIPTION "TRAP: COM6 actual configured UART parity." ::= 804 sdsETSuartInBytes_COM1-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsETSuartInBytes_COM1 } DESCRIPTION "TRAP: COM6 total number of UART IN bytes." ::= 805 sdsETSuartOutBytes_COM1trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsETSuartOutBytes_COM1 } DESCRIPTION "TRAP: COM6 total number of UART OUT bytes." ::= 806 sdsCOM6baudrate-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsCOM6baudrate } DESCRIPTION "TRAP: COM6 actual configured UART baud rate in [bps]." ::= 811 sdsCOM6dataSize-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsCOM6dataSize } DESCRIPTION "TRAP: COM6 actual configured UART char data size [num of bits]." ::= 812 sdsCOM6stopBits-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsCOM6stopBits } DESCRIPTION "TRAP: COM6 actual configured UART number of stop bits." ::= 813 sdsCOM6parity-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsCOM6parity } DESCRIPTION "TRAP: COM6 actual configured UART parity." ::= 814 sdsCOM6uartInBytes-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsCOM6uartInBytes } DESCRIPTION "TRAP: COM1 total number of UART IN bytes." ::= 815 sdsCOM6uartOutBytes-trap TRAP-TYPE STATUS current ENTERPRISE mib-AN-Dcz-SDS VARIABLES { sdsCOM6uartOutBytes } DESCRIPTION "TRAP: COM1 total number of UART OUT bytes." ::= 816 -- end END