-- ***************************************************************** -- MY-SYSTEM-MIB.mib: My System MIB file -- -- $Copyright$ -- -- ***************************************************************** -- MY-SYSTEM-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32 FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF myMgmt FROM MY-SMI; mySystemMIB MODULE-IDENTITY LAST-UPDATED "200203200000Z" ORGANIZATION "$Company$" CONTACT-INFO " Tel: $Telephone$ E-mail: $E-mail$" DESCRIPTION "This module defines my system mibs." REVISION "200203200000Z" DESCRIPTION "Initial version of this MIB module." ::= { myMgmt 1} mySystemMIBObjects OBJECT IDENTIFIER ::= { mySystemMIB 1 } mySystemHwVersion OBJECT-TYPE SYNTAX DisplayString(SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the Revision number of hardware resides on the FastSwitch." ::= { mySystemMIBObjects 1 } mySystemSwVersion OBJECT-TYPE SYNTAX DisplayString(SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the Revision number of software resides on the FastSwitch." ::= { mySystemMIBObjects 2 } mySystemBootVersion OBJECT-TYPE SYNTAX DisplayString(SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the Revision number of BOOT software resides on the FastSwitch." ::= { mySystemMIBObjects 3 } mySystemSysCtrlVersion OBJECT-TYPE SYNTAX DisplayString(SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the Revision number of CTRL software resides on the FastSwitch." ::= { mySystemMIBObjects 4 } mySystemParametersSave OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Save all parameters changed in configuration by setting this object to any value but 0, set its value to 0 will cause no action of agent, otherwise all changes of prarameters will be saved for retrive when system is reset, if parameter is changed but not saved all changes will come to their original value when system down and up again, when query always return value 0." ::= { mySystemMIBObjects 5 } mySystemOutBandRate OBJECT-TYPE SYNTAX INTEGER { baud9600 (1), baud19200 (2), baud38400 (3), baud57600 (4), baud115200 (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determine the console(OutBand) baud rate : 9600 - 1,19200 - 2, 38300 - 3, 57600 - 4, 115200 - 5, when the console baud rate is other value will return value 0." ::= { mySystemMIBObjects 6 } mySystemReset OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This Object allow perform soft reset of system by setting its value to none zero. if a soft resetis performed, after this having completed a warm start trap will send to declare the state and when queried will always return 0." ::= { mySystemMIBObjects 7 } mySwitchLayer OBJECT-TYPE SYNTAX INTEGER { layer2 (1), -- Layer 2 Switch layer3 (2), -- Layer 3 Switch router(3) -- Router } MAX-ACCESS read-only STATUS current DESCRIPTION "Which layer's device the switch in system " ::= { mySystemMIBObjects 8 } mySystemHwPower OBJECT-TYPE SYNTAX INTEGER{ rpsNoLink(1), rpsLinkAndNoPower(2), rpsLinkAndReadyForPower(3), rpsLinkAndPower(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of power." ::= { mySystemMIBObjects 9 } mySystemHwFan OBJECT-TYPE SYNTAX INTEGER{ work(1), stop(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of fan." ::= { mySystemMIBObjects 10 } --The mySystemOutBandTimeout is obsoleted after 2007.9 mySystemOutBandTimeout OBJECT-TYPE SYNTAX Integer32(0..3600) UNITS "seconds" MAX-ACCESS read-write STATUS obsolete DESCRIPTION "The timeout of console.0 indicate that timeout function is disabled." ::= { mySystemMIBObjects 11 } --The mySystemTelnetTimeout is obsoleted after 2007.9 mySystemTelnetTimeout OBJECT-TYPE SYNTAX Integer32(0..3600) UNITS "seconds" MAX-ACCESS read-write STATUS obsolete DESCRIPTION "The timeout of telnet.0 indicate that timeout function is disabled." ::= { mySystemMIBObjects 12 } mySystemMainFile OBJECT-TYPE SYNTAX DisplayString(SIZE (1..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the name of main file on the FastSwitch." ::= { mySystemMIBObjects 13 } mySystemCurrentPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the current power of the FastSwitch." ::= { mySystemMIBObjects 14 } mySystemRemainPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the remain power of the FastSwitch." ::= { mySystemMIBObjects 15 } mySystemTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the temperature of the FastSwitch." ::= { mySystemMIBObjects 16 } mySystemElectricalSourceNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the electrical source number of the FastSwitch." ::= { mySystemMIBObjects 17 } mySystemElectricalSourceIsNormalTable OBJECT-TYPE SYNTAX SEQUENCE OF MySystemElectricalSourceIsNormalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of electrical source entries. Each object displays whether different electrical sources are normal or not." ::= { mySystemMIBObjects 18 } mySystemElectricalSourceIsNormalEntry OBJECT-TYPE SYNTAX MySystemElectricalSourceIsNormalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays whether different electrical sources are normal or not." INDEX { mySystemElectricalSourceIsNormalIndex } ::= { mySystemElectricalSourceIsNormalTable 1 } MySystemElectricalSourceIsNormalEntry ::= SEQUENCE { mySystemElectricalSourceIsNormalIndex Integer32, mySystemElectricalSourceIsNormal INTEGER, mySystemElectricalSourceName DisplayString } mySystemElectricalSourceIsNormalIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a electrical source." ::= { mySystemElectricalSourceIsNormalEntry 1 } mySystemElectricalSourceIsNormal OBJECT-TYPE SYNTAX INTEGER { noexist (1), --no exist existnopower (2), -- exist no power existreadypower (3), --exist ready power normal (4), --normal powerbutabnormal (5), --power but abnormal unknow (6) --unknow } MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays whether an electrical source is normal or not." ::= { mySystemElectricalSourceIsNormalEntry 2 } mySystemElectricalSourceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of electrical source" ::= { mySystemElectricalSourceIsNormalEntry 3 } mySystemCurrentVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the current voltage of the FastSwitch." ::= { mySystemMIBObjects 19 } mySystemFanNUM OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the number of fan on the FastSwitch." ::= { mySystemMIBObjects 20 } mySystemFanIsNormalTable OBJECT-TYPE SYNTAX SEQUENCE OF MySystemFanIsNormalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of fan entries. Each object displays whether different fans are normal or not." ::= { mySystemMIBObjects 21 } mySystemFanIsNormalEntry OBJECT-TYPE SYNTAX MySystemFanIsNormalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays whether different fans are normal or not." INDEX { mySystemFanIsNormalIndex } ::= { mySystemFanIsNormalTable 1 } MySystemFanIsNormalEntry ::= SEQUENCE { mySystemFanIsNormalIndex Integer32, mySystemFanIsNormal INTEGER, mySystemFanName DisplayString } mySystemFanIsNormalIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a fan." ::= { mySystemFanIsNormalEntry 1 } mySystemFanIsNormal OBJECT-TYPE SYNTAX INTEGER { noexist (1), --no exist existnopower (2), -- exist no power existreadypower (3), --exist ready power normal (4), --normal powerbutabnormal (5), --power but abnormal unknow (6) --unknow } MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays whether an fan is normal or not." ::= { mySystemFanIsNormalEntry 2 } mySystemFanName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of fan" ::= { mySystemFanIsNormalEntry 3 } mySystemReloadTimeRemain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the remain time of reloading on the FastSwitch." ::= { mySystemMIBObjects 22 } mySystemTemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF MySystemTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of temperature entries. Each object displays the temperature information." ::= { mySystemMIBObjects 23 } mySystemTemperatureEntry OBJECT-TYPE SYNTAX MySystemTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the temperature information." INDEX { mySystemTemperatureIndex } ::= { mySystemTemperatureTable 1 } MySystemTemperatureEntry ::= SEQUENCE { mySystemTemperatureIndex Integer32, mySystemTemperatureName DisplayString, mySystemTemperatureCurrent Integer32, mySystemTemperatureWarningValue Integer32, mySystemTemperatureCritialValue Integer32 } mySystemTemperatureIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device's temperature information." ::= { mySystemTemperatureEntry 1 } mySystemTemperatureName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual name assigned to a temperature chip" ::= { mySystemTemperatureEntry 2 } mySystemTemperatureCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the current temperature of the FastSwitch.The temperature display is not supported for the current temperature returns to 0." ::= { mySystemTemperatureEntry 3 } mySystemTemperatureWarningValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The first warning of temperature of FastSwitch." ::= { mySystemTemperatureEntry 4 } mySystemTemperatureCritialValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The second warning of temperature of FastSwitch." ::= { mySystemTemperatureEntry 5 } mySystemSerialno OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the serial number resides on the FastSwitch." ::= { mySystemMIBObjects 24 } mySystemVersionTable OBJECT-TYPE SYNTAX SEQUENCE OF MySystemVersionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of system version entries. Each object displays the system version information." ::= { mySystemMIBObjects 25 } mySystemVersionEntry OBJECT-TYPE SYNTAX MySystemVersionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the system version information." INDEX { mySystemVersionIndex } ::= { mySystemVersionTable 1 } MySystemVersionEntry ::= SEQUENCE { mySystemVersionIndex Unsigned32, mySystemVersionName DisplayString, mySystemVersionSwBoot DisplayString, mySystemVersionSwCtrl DisplayString, mySystemVersionSwMain DisplayString, mySystemVersionHw DisplayString, mySystemVersionSerialno DisplayString } mySystemVersionIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device's system version information." ::= { mySystemVersionEntry 1 } mySystemVersionName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual name assigned to a system version chip" ::= { mySystemVersionEntry 2 } mySystemVersionSwBoot OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the software boot system version of the FastSwitch." ::= { mySystemVersionEntry 3 } mySystemVersionSwCtrl OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the software ctrl system version of the FastSwitch." ::= { mySystemVersionEntry 4 } mySystemVersionSwMain OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the software main system version of the FastSwitch." ::= { mySystemVersionEntry 5 } mySystemVersionHw OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the hardware system version of the FastSwitch." ::= { mySystemVersionEntry 6 } mySystemVersionSerialno OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the serial number of the FastSwitch." ::= { mySystemVersionEntry 7 } mySystemMIBTraps OBJECT IDENTIFIER ::= { mySystemMIB 2 } mySystemHardChangeDesc OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The description of hard change" ::= { mySystemMIBTraps 1 } mySystemHardChangeDetected NOTIFICATION-TYPE OBJECTS {mySystemHardChangeDesc} STATUS current DESCRIPTION "System hardware has changed include number of devices or number of modules or the place or type of the module is change." ::= { mySystemMIBTraps 2 } mySystemPowerStateChange NOTIFICATION-TYPE OBJECTS {mySystemHwPower} STATUS current DESCRIPTION "while the state of power changed, then this trap will be sent." ::= { mySystemMIBTraps 3 } mySystemFanStateChange NOTIFICATION-TYPE OBJECTS {mySystemHwFan} STATUS current DESCRIPTION "while the state of fan changed, then this trap will be sent." ::= { mySystemMIBTraps 4 } mySystemMIBConformance OBJECT IDENTIFIER ::= { mySystemMIB 3 } mySystemMIBCompliances OBJECT IDENTIFIER ::= { mySystemMIBConformance 1 } mySystemMIBGroups OBJECT IDENTIFIER ::= { mySystemMIBConformance 2 } -- compliance statements mySystemMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the My System MIB" MODULE -- this module MANDATORY-GROUPS { mySystemMIBGroup } ::= { mySystemMIBCompliances 1 } -- units of conformance mySystemMIBGroup OBJECT-GROUP OBJECTS { mySystemHwVersion, mySystemSwVersion, mySystemBootVersion, mySystemSysCtrlVersion, mySystemParametersSave, mySystemReset, mySystemOutBandRate, mySwitchLayer } STATUS current DESCRIPTION "A collection of objects providing system information and opertion to a My agent." ::= { mySystemMIBGroups 1 } END