IEEE8021-PE-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Counter64 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF MacAddress, TEXTUAL-CONVENTION, TimeStamp, TruthValue FROM SNMPv2-TC ieee802dot1mibs, IEEE8021PbbComponentIdentifier, IEEE8021BridgePortNumber, IEEE8021BridgePortNumberOrZero FROM IEEE8021-TC-MIB PortList FROM Q-BRIDGE-MIB; ieee8021BridgePEMib MODULE-IDENTITY LAST-UPDATED "201201220000Z" -- January 22, 2012, 0000Z ORGANIZATION "IEEE 802.1 Working Group" CONTACT-INFO "WG-URL: http:////www.ieee802.org/1/ WG-EMail: stds-802-1-L@IEEE.ORG Contact: Tony Jeffree Postal: C/O IEEE 802.1 Working Group IEEE Standards Association 445 Hoes Lane Piscataway NJ 08854 USA E-mail: stds-802-1-L@IEEE.ORG" DESCRIPTION "The PE MIB module for managing devices that support Bridge Port Extension. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1BR-2012. Copyright (C) IEEE. This version of this MIB module is part of IEEE 802.1BR-2012; see the specification itself for full legal notices." REVISION "201201220000Z" -- January 22, 2012, 0000Z DESCRIPTION "Initial version published as part of IEEE Std. 802.1BR-2012" ::= { ieee802dot1mibs 25 } -- ============================================================= -- subtrees in the PE MIB -- ============================================================= ieee8021BridgePENotifications OBJECT IDENTIFIER ::= { ieee8021BridgePEMib 1 } ieee8021BridgePEObjects OBJECT IDENTIFIER ::= { ieee8021BridgePEMib 2 } ieee8021BridgePEConformance OBJECT IDENTIFIER ::= { ieee8021BridgePEMib 3 } -- Textual Conventions IEEE802BridgePEEChannelIDTC ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "Textual convention of an E-Channel Identifier." SYNTAX Unsigned32 (1..4194302) IEEE802BridgePETrafficClassValueTC ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "Indicates a traffic class. Values 0-7 correspond to traffic classes." SYNTAX Unsigned32 (0..7) IEEE802BridgePETrafficSelectionAlgorithmTC ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the Traffic Selection Algorithm 0: Strict Priority 1: Credit-based shaper 2: Enhanced transmission selection 3-254: Reserved for furture standardization 255: Vendor specific" SYNTAX INTEGER { tsaStrictPriority(0), tsaCreditBasedShaper(1), tsaEnhancedTransmission(2), tsaVendorSpecific(255) } IEEE802BridgePETrafficClassBandwidthValue ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "Indicates the bandwidth in percent assigned to a traffic class." SYNTAX Unsigned32 (0..100) -- PE port table entry managed object ieee8021BridgePEPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021BridgePEPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains per port information related to Port Extension. A row is created in this table for any port on a Controlling Bridge that is extended using Port Extension, including those ports that provide communication to the Port Extenders themselves." REFERENCE "10.2.1" ::= { ieee8021BridgePEObjects 1 } ieee8021BridgePEPortEntry OBJECT-TYPE SYNTAX Ieee8021BridgePEPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of per port Port Extension objects." INDEX { ieee8021BridgePEPortComponentId, ieee8021BridgePEPort, ieee8021BridgePEPortType } ::= { ieee8021BridgePEPortTable 1 } Ieee8021BridgePEPortEntry ::= SEQUENCE { ieee8021BridgePEPortComponentId IEEE8021PbbComponentIdentifier, ieee8021BridgePEPort IEEE8021BridgePortNumber, ieee8021BridgePEPortType INTEGER, ieee8021BridgePEPortUpstreamCSPAddress MacAddress, ieee8021BridgePEPortEcid IEEE802BridgePEEChannelIDTC, ieee8021BridgePEPortNumber IEEE8021BridgePortNumberOrZero, ieee8021BridgePECounterDiscontinuityTime TimeStamp, ieee8021BridgePEPortRxrqErrorsBridge Counter64, ieee8021BridgePEPortRxrspErrorsBridge Counter64, ieee8021BridgePEPortRxrqErrorsPE Counter64, ieee8021BridgePEPortRxrspErrorsPE Counter64, ieee8021BridgePEPCP TruthValue, ieee8021BridgePEROW TruthValue, ieee8021BridgePEDEI TruthValue, ieee8021BridgePECN TruthValue, ieee8021BridgePEPFC TruthValue, ieee8021BridgePEExtPortEChannelsSupported Unsigned32, ieee8021BridgePERemoteRepEChannelsSupported Unsigned32, ieee8021BridgePETCsSupported Unsigned32, ieee8021BridgePEUtVLANsSupported Unsigned32 } ieee8021BridgePEPortComponentId OBJECT-TYPE SYNTAX IEEE8021PbbComponentIdentifier MAX-ACCESS not-accessible STATUS current DESCRIPTION "The component identifier is used to distinguish between the multiple virtual bridge instances within a PBB. In simple situations where there is only a single component the default value is 1." ::= { ieee8021BridgePEPortEntry 1 } ieee8021BridgePEPort OBJECT-TYPE SYNTAX IEEE8021BridgePortNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "The port number of the port for which this entry contains bridge management information." ::= { ieee8021BridgePEPortEntry 2 } ieee8021BridgePEPortType OBJECT-TYPE SYNTAX INTEGER { pepCascade(1), pepUpstream(2), pepExtended(3) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "The operational mode of a port participating in Port Exension. The enumerated values are: pepCascade - the port is operating as a Cascade port pepUpstream - the port is operating as an Upstream port pepExtended - the port is operating as an Extended port" REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 3 } ieee8021BridgePEPortUpstreamCSPAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC address used for communication of the PE CSP protocol of the device connected to the upstream port of the Port Extender (which may be the Controlling Bridge or an upstream Port Extender). This provides the hierarchal relationship in a cascade of Port Extenders" REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 4 } ieee8021BridgePEPortEcid OBJECT-TYPE SYNTAX IEEE802BridgePEEChannelIDTC MAX-ACCESS read-only STATUS current DESCRIPTION "The default ECID assigend to this port and the port on the Port Extender to which this port corresponds." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 5 } ieee8021BridgePEPortNumber OBJECT-TYPE SYNTAX IEEE8021BridgePortNumberOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The Port number on the of the Port on the Port Extender, or zero for the Upstream Port." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 6 } ieee8021BridgePECounterDiscontinuityTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime on the most recent occasion at which any one or more of the counters in this conceptaul row suffered a discontinuity. The relevant counters are the specific instances associated with this conceptual row of any Counter32 or Counter64 object. If no such discontinuities have occurred since the last re-initialization of the local management subsystem, then this object contains a zero value." ::= { ieee8021BridgePEPortEntry 7 } ieee8021BridgePEPortRxrqErrorsBridge OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PE CSP flow control overflow errors that have occured for requests on the Bridge." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 8 } ieee8021BridgePEPortRxrspErrorsBridge OBJECT-TYPE SYNTAX Counter64 UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PE CSP flow control overflow errors that have occured for responses on the Bridge." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 9 } ieee8021BridgePEPortRxrqErrorsPE OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PE CSP flow control overflow errors that have occured for requests on the Port Extender." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 10 } ieee8021BridgePEPortRxrspErrorsPE OBJECT-TYPE SYNTAX Counter64 UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PE CSP flow control overflow errors that have occured for responses on the Port Extender." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 11 } ieee8021BridgePEPCP OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the Port Exender supports modification of the priority code point table (true) or not (false)." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 12 } ieee8021BridgePEROW OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the Port Extender supports rows in the PCP table in addition to the 8P0D row (true)or not (false)." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 13 } ieee8021BridgePEDEI OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the Port Extender supports encoding of the Drop Eligible Indicatior (true) or not (false)." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 14 } ieee8021BridgePECN OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the Port Extender supports Congestion Notification (true) or not (false)." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 15 } ieee8021BridgePEPFC OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the Port Extender supports Priority-based flow control(true) or not (false)." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 16 } ieee8021BridgePEExtPortEChannelsSupported OBJECT-TYPE SYNTAX Unsigned32 (1..1048575) UNITS "E-channels" MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of Extended Port E-channels supported by the Port Extender." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 17 } ieee8021BridgePERemoteRepEChannelsSupported OBJECT-TYPE SYNTAX Unsigned32 (1..3145727) UNITS "E-channels" MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of Remote Replication E-channels supported by the Port Extender." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 18 } ieee8021BridgePETCsSupported OBJECT-TYPE SYNTAX Unsigned32 (1..8) UNITS "traffic classes" MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of traffic clasees supported by the Port Extender." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 19 } ieee8021BridgePEUtVLANsSupported OBJECT-TYPE SYNTAX Unsigned32 (1..4094) UNITS "VLANs" MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of untagged VLANs supported by the Port Extender." REFERENCE "10.2.1" ::= { ieee8021BridgePEPortEntry 20 } -- PE Remote Replication entry table managed object ieee8021BridgePERemoteReplicationTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021BridgePERemoteReplicationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains one row for each Remote Replication entry in the filtering database." REFERENCE "10.3.1" ::= { ieee8021BridgePEObjects 2 } ieee8021BridgePERemoteReplicationEntry OBJECT-TYPE SYNTAX Ieee8021BridgePERemoteReplicationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Remote Replication objects." INDEX { ieee8021BridgePEPortComponentId, ieee8021BridgePERREcid } ::= { ieee8021BridgePERemoteReplicationTable 1 } Ieee8021BridgePERemoteReplicationEntry ::= SEQUENCE { ieee8021BridgePERREcid IEEE802BridgePEEChannelIDTC, ieee8021BridgePERRPortMap PortList } ieee8021BridgePERREcid OBJECT-TYPE SYNTAX IEEE802BridgePEEChannelIDTC MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ECID assigend to this Remote Replication filtering entry." REFERENCE "10.3.1" ::= { ieee8021BridgePERemoteReplicationEntry 1 } ieee8021BridgePERRPortMap OBJECT-TYPE SYNTAX PortList MAX-ACCESS read-only STATUS current DESCRIPTION "The list of ports to which a frame is to be replicated." REFERENCE "10.3.1" ::= { ieee8021BridgePERemoteReplicationEntry 2 } --PE Enhanced Transmission Selection table managed object ieee8021BridgePEETSTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021BridgePEETSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains per port information related to Enhanced Transmission Selection. A row is created in this table for any port on a Controlling Bridge that corresponds to a Cascade Port. These objects refer to the ETS configuration of the attached Upstream Port" REFERENCE "10.2.2" ::= { ieee8021BridgePEObjects 3 } ieee8021BridgePEETSEntry OBJECT-TYPE SYNTAX Ieee8021BridgePEETSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of per Cascade Port ETS objects." INDEX { ieee8021BridgePEPortComponentId, ieee8021BridgePEPort, ieee8021BridgePEETSTrafficClass } ::= { ieee8021BridgePEETSTable 1 } Ieee8021BridgePEETSEntry ::= SEQUENCE { ieee8021BridgePEETSTrafficClass IEEE802BridgePETrafficClassValueTC, ieee8021BridgePEETSTrafficSelectionAlgorthm IEEE802BridgePETrafficSelectionAlgorithmTC, ieee8021BridgePEETSBandwidth IEEE802BridgePETrafficClassBandwidthValue } ieee8021BridgePEETSTrafficClass OBJECT-TYPE SYNTAX IEEE802BridgePETrafficClassValueTC MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the traffic class to which this bandwidth applies" REFERENCE "10.2.3" ::= { ieee8021BridgePEETSEntry 1 } ieee8021BridgePEETSTrafficSelectionAlgorthm OBJECT-TYPE SYNTAX IEEE802BridgePETrafficSelectionAlgorithmTC MAX-ACCESS read-write STATUS current DESCRIPTION "Inticates the Traffic Selection Algorthm assigned to this traffic class" REFERENCE "10.2.3" ::= { ieee8021BridgePEETSEntry 2 } ieee8021BridgePEETSBandwidth OBJECT-TYPE SYNTAX IEEE802BridgePETrafficClassBandwidthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the bandwidth assigned to this traffic class." REFERENCE "10.2.3" ::= { ieee8021BridgePEETSEntry 3 } -- ============================================================= -- Conformance Information -- ============================================================= ieee8021BridgePEGroups OBJECT IDENTIFIER ::= { ieee8021BridgePEConformance 1 } ieee8021BridgePECompliances OBJECT IDENTIFIER ::= { ieee8021BridgePEConformance 2 } -- ============================================================= -- Units of conformance -- ============================================================= ieee8021BridgePEGroup OBJECT-GROUP OBJECTS { ieee8021BridgePEPortUpstreamCSPAddress, ieee8021BridgePEPortEcid, ieee8021BridgePEPortNumber, ieee8021BridgePECounterDiscontinuityTime, ieee8021BridgePEPortRxrqErrorsBridge, ieee8021BridgePEPortRxrspErrorsBridge, ieee8021BridgePEPortRxrqErrorsPE, ieee8021BridgePEPortRxrspErrorsPE, ieee8021BridgePEPCP, ieee8021BridgePEROW, ieee8021BridgePEDEI, ieee8021BridgePECN, ieee8021BridgePEPFC, ieee8021BridgePEExtPortEChannelsSupported, ieee8021BridgePERemoteRepEChannelsSupported, ieee8021BridgePETCsSupported, ieee8021BridgePEUtVLANsSupported, ieee8021BridgePERRPortMap, ieee8021BridgePEETSTrafficSelectionAlgorthm, ieee8021BridgePEETSBandwidth } STATUS current DESCRIPTION "The collection of objects used to represent Port Extension management objects." ::= { ieee8021BridgePEGroups 1 } -- ============================================================= -- compliance statements -- ============================================================= ieee8021BridgePECompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for devices supporting PE as defined in IEEE 802.1BR." MODULE -- this module MANDATORY-GROUPS { ieee8021BridgePEGroup } ::= { ieee8021BridgePECompliances 1 } END