-- ************************************************************** -- Redline AN50-PMP MIB -- ECO Rev 1.00 -- Copyright (c) 2006 by Redline Communications, Inc -- All rights reserved -- ************************************************************** REDLINE-AN50-PMP-V1-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, IpAddress, enterprises,TimeTicks FROM RFC1155-SMI RowStatus FROM SNMPv2-TC; -- ORGANIZATION "Redline Communications, Inc." -- postal: Redline Communications Inc. -- 302 Town Centre Blvd Suite 100 -- Markham Ontario L3R 0E8 -- Canada -- phone: +1 905 479-8344 -- DESCRIPTION "This MIB contains Redline-defined attributes for -- AN-50 PMP switched device based on V1 processor. The device can -- connect multiple subscriber stations to a central -- base station." -- LAST-UPDATED "200304050930Z" -- Author: Bogdan Moldoveanu -- DESCRIPTION "MIB module for AN50PMP V1 Processor." -- LAST-UPDATED "200308200000Z" -- Author: Bogdan Moldoveanu -- DESCRIPTION "Added an50pmpLastModifiedCID" -- LAST-UPDATED "200401070000Z" -- Author: Bogdan Moldoveanu -- DESCRIPTION "Added an50pmpLastMissedSsMacAddress" -- LAST-UPDATED "200401080000Z" -- Author: Bogdan Moldoveanu -- DESCRIPTION "Added an50pmpLastRegisteredSsMacAddress" -- LAST-UPDATED "200408040000Z" -- Author: Ioan Cautil -- DESCRIPTION "Completed descriptions of mib nodes" -- LAST-UPDATED "200601160000Z" -- Author: Mark Fairclough -- DESCRIPTION "spelling and update to Redline address" --textual convention -- Registration of object identifiers redline OBJECT IDENTIFIER ::= { enterprises 10728 } redlineProducts OBJECT IDENTIFIER ::= { redline 1 } redlineMgmt OBJECT IDENTIFIER ::= { redline 2 } redlineAN50 OBJECT IDENTIFIER ::= { redlineProducts 1 } redlineAN50PMPV1 OBJECT IDENTIFIER ::= {redlineMgmt 51} -- ----------------------------- -- Link and Connections Table -- ----------------------------- an50pmpLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF An50pmpLinkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table with Wireless links and connections information configured into AN50 PMP device based on V1 processor." ::= {redlineAN50PMPV1 1} an50pmpLinkEntry OBJECT-TYPE SYNTAX An50pmpLinkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A unique set of link parameters." INDEX {an50pmpLinkID} ::= {an50pmpLinkTable 1} An50pmpLinkEntry ::= SEQUENCE { an50pmpLinkID INTEGER, an50pmpLinkName OCTET STRING, an50pmpLinkGroupID INTEGER, an50pmpLinkPeerMac OCTET STRING, an50pmpLinkMaxDLBurstRate INTEGER, an50pmpLinkMaxULBurstRate INTEGER, an50pmpLinkMaxHost INTEGER, an50pmpLinkCIDDLCIR INTEGER, an50pmpLinkCIDDLPIR INTEGER, an50pmpLinkCIDULCIR INTEGER, an50pmpLinkCIDULPIR INTEGER, an50pmpLinkDLQoS INTEGER, an50pmpLinkULQoS INTEGER, an50pmpLinkRowStatus RowStatus } an50pmpLinkID OBJECT-TYPE SYNTAX INTEGER (1 .. 1024) ACCESS read-only STATUS mandatory DESCRIPTION "Link ID, a unique number between 1 and 1024 that identifies a particular link." ::= {an50pmpLinkEntry 1} an50pmpLinkName OBJECT-TYPE SYNTAX OCTET STRING(SIZE(1..8)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of the Link/Connection " ::= {an50pmpLinkEntry 2} an50pmpLinkGroupID OBJECT-TYPE SYNTAX INTEGER(1 .. 1024) ACCESS read-write STATUS mandatory DESCRIPTION "Group assigned to this link." ::= {an50pmpLinkEntry 3} an50pmpLinkPeerMac OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Link Destination MAC address." ::= {an50pmpLinkEntry 4} an50pmpLinkMaxDLBurstRate OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-write STATUS mandatory DESCRIPTION "Maximum downlink rate for this link. Rate range: 6Mb/s=1, 9Mb/s=2, 12Mb/s=3, 18Mb/s=4, 24Mb/s=5, 36Mb/s=6, 48Mb/s=7, 54Mbs=8." ::= {an50pmpLinkEntry 5} an50pmpLinkMaxULBurstRate OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-write STATUS mandatory DESCRIPTION "Maximum uplink rate for this link. Rate range: 6Mb/s=1, 9Mb/s=2, 12Mb/s=3, 18Mb/s=4, 24Mb/s=5, 36Mb/s=6, 48Mb/s=7, 54Mbs=8." ::= {an50pmpLinkEntry 6} an50pmpLinkMaxHost OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Maximum number of hosts for this link." ::= {an50pmpLinkEntry 7} an50pmpLinkCIDDLCIR OBJECT-TYPE SYNTAX INTEGER (0 .. 65535) ACCESS read-write STATUS mandatory DESCRIPTION "The downlink commited rate for this connection in kb/s." ::= {an50pmpLinkEntry 8} an50pmpLinkCIDDLPIR OBJECT-TYPE SYNTAX INTEGER (0 .. 65535) ACCESS read-write STATUS mandatory DESCRIPTION "The downlink peak rate for this connection in kb/s." ::= {an50pmpLinkEntry 9} an50pmpLinkCIDULCIR OBJECT-TYPE SYNTAX INTEGER (0 .. 65535) ACCESS read-write STATUS mandatory DESCRIPTION "The uplink commited rate for this connection in kb/s." ::= {an50pmpLinkEntry 10} an50pmpLinkCIDULPIR OBJECT-TYPE SYNTAX INTEGER (0 .. 65535) ACCESS read-write STATUS mandatory DESCRIPTION "The uplink peak rate for this connection in kb/s." ::= {an50pmpLinkEntry 11} an50pmpLinkDLQoS OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-write STATUS mandatory DESCRIPTION "The downlink QoS level." ::= {an50pmpLinkEntry 12} an50pmpLinkULQoS OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-write STATUS mandatory DESCRIPTION "The uplink QoS level." ::= {an50pmpLinkEntry 13} an50pmpLinkRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Status of the row" ::= {an50pmpLinkEntry 14} an50pmpLinkStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF An50pmpLinkStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Statistics per uplink connections." ::= {redlineAN50PMPV1 2} an50pmpLinkStatusEntry OBJECT-TYPE SYNTAX An50pmpLinkStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Statistics for a link connection." INDEX {an50pmpLinkID} ::= {an50pmpLinkStatusTable 1} An50pmpLinkStatusEntry ::= SEQUENCE { an50pmpLinkStatusID INTEGER, an50pmpLinkStatus INTEGER, an50pmpLinkStatusCode INTEGER, an50pmpLinkRegConn INTEGER, an50pmpLinkDLBurstRate INTEGER, an50pmpLinkDLRSSI INTEGER, an50pmpLinkDLSINADR INTEGER, an50pmpLinkDLStatLostFrm INTEGER, an50pmpLinkDLStatBlksTot INTEGER, an50pmpLinkDLStatBlksRetr INTEGER, an50pmpLinkDLStatBlksDisc INTEGER, an50pmpLinkDLCIDStatPktDisc INTEGER, an50pmpLinkDLCIDStatPktTran INTEGER, an50pmpLinkDLCIDStatPktRecv INTEGER, an50pmpLinkULBurstRate INTEGER, an50pmpLinkULRSSI INTEGER, an50pmpLinkULSINADR INTEGER, an50pmpLinkULStatLostFrm INTEGER, an50pmpLinkULStatBlksTot INTEGER, an50pmpLinkULStatBlksRetr INTEGER, an50pmpLinkULStatBlksDisc INTEGER, an50pmpLinkULCIDStatPktDisc INTEGER, an50pmpLinkULCIDStatPktTran INTEGER, an50pmpLinkULCIDStatPktRecv INTEGER, an50pmpLinkUpTime TimeTicks, an50pmpLinkLostCount INTEGER } an50pmpLinkStatusID OBJECT-TYPE SYNTAX INTEGER (1 .. 1024) ACCESS read-only STATUS mandatory DESCRIPTION "Index for an50pmpLinkStatusTable table" ::= {an50pmpLinkStatusEntry 1} an50pmpLinkStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of the Link." ::= {an50pmpLinkStatusEntry 2} an50pmpLinkStatusCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Alarm bits shown as a hex number." ::= {an50pmpLinkStatusEntry 3} an50pmpLinkRegConn OBJECT-TYPE SYNTAX INTEGER (1 .. 1024) ACCESS read-only STATUS mandatory DESCRIPTION "Number of connections configured for this link." ::= {an50pmpLinkStatusEntry 4} an50pmpLinkDLBurstRate OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Current master Tx burst rate. Rate range: 6Mb/s=1, 9Mb/s=2, 12Mb/s=3, 18Mb/s=4, 24Mb/s=5, 36Mb/s=6, 48Mb/s=7, 54Mbs=8. " ::= {an50pmpLinkStatusEntry 5} an50pmpLinkDLRSSI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "RSSI (Received Signal Strength Indicator) at slave." ::= {an50pmpLinkStatusEntry 6} an50pmpLinkDLSINADR OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SINADR (Signal Interference and Noise Distorsion Ratio) at slave." ::= {an50pmpLinkStatusEntry 7} an50pmpLinkDLStatLostFrm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SINADR at slave." ::= {an50pmpLinkStatusEntry 8} an50pmpLinkDLStatBlksTot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blocks transmitted from master to slave." ::= {an50pmpLinkStatusEntry 9} an50pmpLinkDLStatBlksRetr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Block re-transmitted from master to slave." ::= {an50pmpLinkStatusEntry 10} an50pmpLinkDLStatBlksDisc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blocks lost from master to slave" ::= {an50pmpLinkStatusEntry 11} an50pmpLinkDLCIDStatPktDisc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Packets discarded by master due to buffer full." ::= {an50pmpLinkStatusEntry 12} an50pmpLinkDLCIDStatPktTran OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Packets transmitted from master to slave." ::= {an50pmpLinkStatusEntry 13} an50pmpLinkDLCIDStatPktRecv OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Packets received by slave" ::= {an50pmpLinkStatusEntry 14} an50pmpLinkULBurstRate OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Current Slave Tx Burst Rate. Rate range: 6Mb/s=1, 9Mb/s=2, 12Mb/s=3, 18Mb/s=4, 24Mb/s=5, 36Mb/s=6, 48Mb/s=7, 54Mbs=8." ::= {an50pmpLinkStatusEntry 15} an50pmpLinkULRSSI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "RSSI at master." ::= {an50pmpLinkStatusEntry 16} an50pmpLinkULSINADR OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SINADR at master." ::= {an50pmpLinkStatusEntry 17} an50pmpLinkULStatLostFrm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Frames lost from slave to master" ::= {an50pmpLinkStatusEntry 18} an50pmpLinkULStatBlksTot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blocks transmitted slave to master." ::= {an50pmpLinkStatusEntry 19} an50pmpLinkULStatBlksRetr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Block re-transmitted slave to master." ::= {an50pmpLinkStatusEntry 20} an50pmpLinkULStatBlksDisc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blocks lost from slave to master." ::= {an50pmpLinkStatusEntry 21} an50pmpLinkULCIDStatPktDisc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Packets discarded by slave due to buffer full." ::= {an50pmpLinkStatusEntry 22} an50pmpLinkULCIDStatPktTran OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Packets transmitted from slave to master." ::= {an50pmpLinkStatusEntry 23} an50pmpLinkULCIDStatPktRecv OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Packets received by master from slave." ::= {an50pmpLinkStatusEntry 24} an50pmpLinkUpTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Time since the link is UP (in hundreth a of second)." ::= {an50pmpLinkStatusEntry 25} an50pmpLinkLostCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times the link has been lost." ::= {an50pmpLinkStatusEntry 26} an50pmpCIDSaveConfig OBJECT-TYPE SYNTAX INTEGER { donothing(1), -- do not save configuration saveConfig(2) -- save configuration } ACCESS read-write STATUS mandatory DESCRIPTION "The attribute saves the entire config set of the AN50 PMP." ::= { redlineAN50PMPV1 3} an50pmpLastModifiedCID OBJECT-TYPE SYNTAX INTEGER (4..1023) ACCESS read-only STATUS mandatory DESCRIPTION "The attribute represents the last modified CID." ::= { redlineAN50PMPV1 4} an50pmpLastMissedSsMacAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "MAC address of the SS that missed the registration with the BS." ::= { redlineAN50PMPV1 5} an50pmpLastRegisteredSsMacAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "MAC address of the last SS that successfuly registered with the BS." ::= { redlineAN50PMPV1 6} an50pmpLastSuccessfulID OBJECT-TYPE SYNTAX INTEGER (4..1023) ACCESS read-only STATUS mandatory DESCRIPTION "The ID of the Link registered in BS table that is sent through LastSuccessfulRegisteredSS Trap(number10)." ::= { redlineAN50PMPV1 7} an50pmpLastDeniedSsMacAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MAC address of the SS that will be denied by thisBS." ::= { redlineAN50PMPV1 8} END