-- ***************************************************************** -- Redline AN-50 MIB -- ECO Rev 1.00 -- ECO Rev 1.0x -- Copyright (c) 2006 by Redline Communications, Inc. -- All rights reserved. -- ***************************************************************** REDLINE-AN50-MIB DEFINITIONS ::= BEGIN IMPORTS IpAddress, Counter, TimeTicks, enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 an50pmpLastModifiedCID, an50pmpLastMissedSsMacAddress, an50pmpLastRegisteredSsMacAddress FROM REDLINE-AN50-PMP-V1-MIB; -- ORGANIZATION "Redline Communications, Inc." -- postal: Redline Communications Inc. -- 302 Town Centre Suite 100 -- Markham Ontario L3R 0E8 -- Canada -- phone: +1 905 479-8344 -- DESCRIPTION "This MIB contains Redline-defined AN-50 attributes." -- LAST-UPDATED "200307240930Z" -- Author: Sinisa Djurkic -- DESCRIPTION "New variables for PMP project intoduced." -- REVISION "200307110930Z" -- Author: Sinisa Djurkic -- DESCRIPTION "Introduced OIDs for the AN30 application." -- REVISION "200301080930Z" -- Author: Sinisa Djurkic -- DESCRIPTION "New AN-50 terminology and new powersupply trap introduced." -- REVISION "200212121145Z" -- Author: Sinisa Djurkic -- Appreciation: Aurel Picu, Alex Parvulescu -- DESCRIPTION "Added scalars for front plate and chassis." -- REVISION "200211030000Z" -- Author: Sinisa Djurkic -- Appreciation: Aurel Picu -- DESCRIPTION "Added scalars from mib-II interface tree." -- REVISION "200210210000Z" -- Author: Sinisa Djurkic -- Appreciation: Aurel Picu, Claude Daniel Ndjouou -- DESCRIPTION "MIB overhauled, complete V1 conversion." -- REVISION "200204090000Z" -- Primary Author: Claude Daniel Ndjouou, Ioan Cautil -- DESCRIPTION "Initial version of this MIB module." -- REVISION "200308200000Z" -- Author: Bogdan Moldoveanu -- DESCRIPTION "Added an50GenChannelAutoScan and the trap an50ModifiedIDTrap." -- REVISION "200401070000Z" -- Author: Bogdan Moldoveanu -- DESCRIPTION "Added an50WrlsDFSAction an50WrlsAntennaGain,an50WrlsATPEnabled and trap an50pmpRegistrationMissed " -- REVISION "200401080000Z" -- Author: Bogdan Moldoveanu -- DESCRIPTION "Added trap an50pmpRegistrationSuccessful " -- REVISION "200401270000Z" -- Author: Bogdan Moldoveanu -- DESCRIPTION "Added trap an50DFSEvent" -- REVISION "200408040000Z" -- Author: Ioan Cautil -- DESCRIPTION "Completed descriptions of mib nodes" -- REVISION "200601160000Z" -- Author: Mark Fairclough c/o Radu Morus -- DESCRIPTION "Added an50etherMgmVid and an50etherLben OIDs" -- Registration of object identifiers redline OBJECT IDENTIFIER ::= { enterprises 10728 } redlineProducts OBJECT IDENTIFIER ::= { redline 1 } redlineMgmt OBJECT IDENTIFIER ::= { redline 2 } redlineAn50 OBJECT IDENTIFIER ::= { redlineMgmt 16} an50General OBJECT IDENTIFIER ::= { redlineAn50 1 } an50Config OBJECT IDENTIFIER ::= { redlineAn50 2 } an50Pm OBJECT IDENTIFIER ::= { redlineAn50 3 } an50Trap OBJECT IDENTIFIER ::= { redlineAn50 4 } an50LinkPmp OBJECT IDENTIFIER ::= { redlineAn50 5 } an50GenUBR OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the system's current uncoded burst rate. With adaptive modulation enabled, this rate may change over time, depending on the prevailing propagation conditions. " ::= { an50General 1 } an50GenRFLink OBJECT-TYPE SYNTAX INTEGER { notConnected(1), -- remote terminal not connected connected(2) -- remote terminal connected } ACCESS read-only STATUS mandatory DESCRIPTION "connected(2) indicates the terminal is communicating properly to the remote terminal. notConnected(1) indicates there is no communication with the remote terminal." ::= { an50General 2 } an50GenFrequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The frequency which represents the operating channel of the link. The system can be configured to operate over 9 distinct channels." ::= { an50General 3 } an50GenAllignmentMode OBJECT-TYPE SYNTAX INTEGER { voltage (1), -- antenna alignment is done with voltage buzzer (2) -- antenna alignment is done with buzzer } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies if the antenna alignment is done with buzzer or voltage." ::= { an50General 4 } an50GenEncryptionEnabled OBJECT-TYPE SYNTAX INTEGER { no (1), -- encryption not enabled yes (2) -- encryption enabled } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies if encryption is enabled or not." ::= { an50General 5 } an50GenFlowControlEnabled OBJECT-TYPE SYNTAX INTEGER { no (1), -- flow control is not enabled yes (2) -- flow control is enabled } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies if flow control is enabled or not." ::= { an50General 6 } an50GenHttpAccessEnabled OBJECT-TYPE SYNTAX INTEGER { no (1), -- Http access is not enabled yes (2) -- Http access is enabled } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies if Http Access is enabled or not." ::= { an50General 7 } an50GenTelnetAccessEnabled OBJECT-TYPE SYNTAX INTEGER { no (1), -- Telnet access is not enabled yes (2) -- Telnet access is enabled } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies if Telnet Access is enabled or not." ::= { an50General 8 } an50GenTelnetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the Telnet port number." ::= { an50General 9 } an50GenOptionsKey OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the Product Options Key." ::= { an50General 10 } an50GenResetDevice OBJECT-TYPE SYNTAX INTEGER { donothing(1), -- do not reset the AN50 terminal reset(2) -- reset the AN50 terminal } ACCESS read-write STATUS mandatory DESCRIPTION "reset(2) indicates to reset the AN50 terminal. donothing(1) indicates do not reset AN50 terminal." ::= { an50General 11 } an50GenFault OBJECT-TYPE SYNTAX INTEGER { off (1), -- fault LED status off on (2), -- fault LED status on unknown (3) -- fault LED status unknown } ACCESS read-only STATUS mandatory DESCRIPTION "The attribute specifies the Fault LED status of the terminal." ::= { an50General 12 } an50GenTxPower OBJECT-TYPE SYNTAX INTEGER (-20 .. 20) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the actual Tx Power of the AN-50 Node in ?" ::= { an50General 13 } an50GenRegisteredStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the actual number of configured links." ::= { an50General 14 } an50GenRegisteredConnections OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the actual number of configured connections." ::= { an50General 15 } an50GenActiveWirelessLinks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the actual number of provisioned links." ::= { an50General 16 } an50GenChannelAutoScan OBJECT-TYPE SYNTAX INTEGER { no (1), -- Auto-Scanning disabled yes (2) -- Auto-Scanning enabled } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the Auto-Scanning feature for the channel." ::= { an50General 17 } an50GenIduType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Indoor Unit Type." ::= { an50General 18 } an50GenOduType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Outdoor Unit Type." ::= { an50General 19 } -- -- Ethernet Configuration Group -- an50ConfigEther OBJECT IDENTIFIER ::= { an50Config 1 } an50EtherMacAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Ethernet MAC address of the local terminal." ::= { an50ConfigEther 1 } an50EtherGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP Gateway of the AN-50 This field is used to specify the IP address of the gateway which the AN-50 is communicating through the core network." ::= { an50ConfigEther 2 } an50EtherPortStatus OBJECT-TYPE SYNTAX INTEGER { down (1), -- Ethernet Port down up (2), -- Ethernet Port up unknown (3) -- Ethernet Port status unknown } ACCESS read-only STATUS mandatory DESCRIPTION "The attribute specifies the status of the Ethernet Port of the AN50." ::= { an50ConfigEther 3 } an50EtherIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the AN-50. The default address from the factory is 192.168.25.2. For the initial set-up, the terminal should not be connected to the Internet network, i.e. the host computer should be connected directly to the terminal Ethernet port, to avoid address conflicts with other devices in a public network. Once the IP address has been set, the terminal can be connected to the core network, where it can receive either static or dynamic addressing (DHCP) in future configuration updates." ::= { an50ConfigEther 4 } an50EtherMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP Subnet Mask of the AN-50. The value is typically set to 255.255.255.0 (Class C subnet), which prevents certain local devices from going out into the wireless network." ::= { an50ConfigEther 5 } an50Ether100 OBJECT-TYPE SYNTAX INTEGER { s10Mbs (1), -- 100 Mb/s Ethernet LED status off s100Mbs (2), -- 100 Mb/s Ethernet LED status on unknown (3) -- 100 Mb/s Ethernet LED status unknown } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the 100 Mb/s Ethernet LED status of the AN50." ::= { an50ConfigEther 6 } an50EtherFd OBJECT-TYPE SYNTAX INTEGER { halfDuplex (1), -- Ethernet FullDuplex LED status off fullDuplex (2), -- Ethernet FullDuplex LED status on unknown (3) -- Ethernet FullDuplex LED status unknown } ACCESS read-only STATUS mandatory DESCRIPTION "The object specifies the Ethernet FullDuplex LED status of the AN50." ::= { an50ConfigEther 7 } an50EtherMgmVidEn OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The attribute specifies the Ethernet Management Vlan Enabled Status of the AN50." ::= { an50ConfigEther 8 } an50EtherMgmVid OBJECT-TYPE SYNTAX INTEGER ( 0..4095 ) ACCESS read-write STATUS mandatory DESCRIPTION "The attribute specifies the Ethernet Management Vlan Id of the AN50." ::= { an50ConfigEther 9 } an50EtherLben OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The attribute specifies the Link Backup Enable Status of the AN50." ::= { an50ConfigEther 10 } -- -- Wireless Configuration Group -- an50ConfigWireless OBJECT IDENTIFIER ::= { an50Config 2 } an50WrlsChannel OBJECT-TYPE SYNTAX INTEGER { chan1 (1), -- 5735 MHz chan1A (2), -- 5745 MHz chan2 (3), -- 5755 MHz chan2A (4), -- 5765 MHz chan3 (5), -- 5775 MHz chan3A (6), -- 5785 MHz chan4 (7), -- 5795 MHz chan4A (8), -- 5805 MHz chan5 (9) -- 5815 MHz } ACCESS read-write STATUS mandatory DESCRIPTION "specifies the operating channel of the system, within the 100 MHz available in the 5.8GHz UNII band. To avoid interference, two PTP links operating in the same physical location (co-located) or within close proximity (e.g. across the street) must be separated by at least one channel, i.e. the gap between channels should be 20 MHz or more (e.g. channels 1 and 3)." ::= { an50ConfigWireless 1 } an50WrlsTxPower OBJECT-TYPE SYNTAX INTEGER (-20 .. 20) ACCESS read-write STATUS mandatory DESCRIPTION "The Tx Power of the AN-50 in dBm. Specifies the power level of the system, which is preset at the factory and should not be altered. In the event that this parameter needs to be changed, please contact the Redline support team." ::= { an50ConfigWireless 2 } an50WrlsModReduction OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "The Modulation Reduction Level of the AN-50. Applies when the Adaptive rate is disabled. Specifies how many levels the system must drop in modulation before beginning re-transmission to address packet errors. The value can be set from 1-7, with 2 being the typical value." ::= { an50ConfigWireless 3 } an50WrlsAdaptiveMod OBJECT-TYPE SYNTAX INTEGER { notAdaptiveRate(1), -- do not operate in adaptive modulation mode adaptiveRate(2) -- operate in adaptive modulation mode } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this attribute to AdaptiveRate(2) sets the system to operate in adaptive modulation mode. It is recommended to keep the AN-50 in this mode so that the system can automatically adjust the modulation level to the highest possible data rate based on measured RF performance. The user can define the minimum desired modulation level by setting the Main rate parameter. If the system meets this data rate, then the Signal LED on the front panel will light continuously green. If packet errors exceed one out of a million, the system will automatically lower the modulation level to maintain the link. In this case, the LED will flash green. If errors continue when the system reaches the lowest modulation level, the LED will flash red to indicate a failed RF link. The user can also disable the dynamic modulation mode by disabling Adaptive Modulation. In this mode, the user is required to set the Burst Rate and the Modulation Reduction Level. It is recommended not to operate the system in manual mode, as this mode is intended primarily for field support. Note the Signal LED will light solid green when the packet error rate is less than 1 out of a million. When the errors exceed this limit, the LED will not illuminate, indicating the RF link has failed." ::= { an50ConfigWireless 4 } an50WrlsUBR OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the desired net uncoded burst rate for the link. Set uncoded burst rate in steps (0=6Mb/s, 1=9Mb/s, 2=12Mb/s, 3=18Mb/s, 4=24Mb/s, 5=36Mb/s, 6=48Mb/s, 7=54Mbs)." ::= { an50ConfigWireless 5 } an50WrlsMaster OBJECT-TYPE SYNTAX INTEGER { ptpSlave(1), -- device is configured as a PTP Slave ptpMaster(2), -- device is configured as a PTP Master pmpSlave(3), -- device is configured as a PMP Slave pmpMaster(4) -- device is configured as a PMP Master } ACCESS read-write STATUS mandatory DESCRIPTION "The object contains the configured mode of the AN50 terminal. 1 = PTP Slave, 2 = PTP Master, 3 = PMP Slave, 4 = PMP Master" ::= { an50ConfigWireless 6 } an50WrlsVersion OBJECT-TYPE SYNTAX INTEGER { firstFlash(1), -- use the software from the first flash memory secondFlash(2) -- use the software from the second flash memory } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the version of the AN50 system software. The software can be remotely downloaded into the AN50. The system comprises sufficient memory to hold two independent software loads. The operator can specify which load to set as the active version." ::= { an50ConfigWireless 7 } an50WrlsEncryptCode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The object contains the Encryption Key used for the AN-50 terminal. Enter the MAC address of the remote terminal to enable over-the-air data encryption." ::= { an50ConfigWireless 8 } an50WrlsCableAttenuation OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the Cable Attenuation for the AN-50 in dB." ::= { an50ConfigWireless 9 } an50WrlsRfPortStatus OBJECT-TYPE SYNTAX INTEGER { down (1), -- AN50s Wireless Port down up (2), -- AN50s Wireless Port up unknown (3) -- AN50s Wireless Port status unknown } ACCESS read-only STATUS mandatory DESCRIPTION "The object specifies the status of the AN50s Wireless Port." ::= { an50ConfigWireless 10 } an50WrlsSaveConfig OBJECT-TYPE SYNTAX INTEGER { donothing(1), -- do not save the config set of the AN50 saveConfig(2) -- save the entire config set of the AN50 } ACCESS read-write STATUS mandatory DESCRIPTION "The object saves the entire config set of the AN50." ::= { an50ConfigWireless 11 } an50WrlsActivateConfig OBJECT-TYPE SYNTAX INTEGER { donothing(1), -- do not activate the config set of the AN50 activeConfig(2) -- activate the entire config set of the AN50 } ACCESS read-write STATUS mandatory DESCRIPTION "The object activates the entire config set of the AN50." ::= { an50ConfigWireless 12 } an50WrlsRadioEnable OBJECT-TYPE SYNTAX INTEGER { txOff (1), -- radio transmission is disabled txOn (2) -- radio transmission is enabled } ACCESS read-write STATUS mandatory DESCRIPTION "The object specifies whether radio transmission is enabled or disabled." ::= { an50ConfigWireless 13 } an50WrlsRfStatusErrorCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The object specifies the Error Code for the RF Status." ::= { an50ConfigWireless 14 } an50WrlsRfSignal OBJECT-TYPE SYNTAX INTEGER { off (1), -- Wireless Signal LED status off on (2), -- Wireless Signal LED status on blinking(3) -- Wireless Signal LED status blinking } ACCESS read-only STATUS mandatory DESCRIPTION "The object specifies the Wireless Signal LED status." ::= { an50ConfigWireless 15 } an50WrlsLLMode OBJECT-TYPE SYNTAX INTEGER { auto (1), -- Link length set automatically manual (2) -- Link length set manually } ACCESS read-write STATUS mandatory DESCRIPTION "Link length set mode." ::= { an50ConfigWireless 16 } an50WrlsLMU OBJECT-TYPE SYNTAX INTEGER { mile (1), -- link measurement unit in mile km (2) -- link measurement unit in Km } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the Link measurements unit (mile / Km)." ::= { an50ConfigWireless 17 } an50WrlsLL OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the Link Length. See an50WrlsLMU object for units." ::= { an50ConfigWireless 18 } an50ConfigScheduler OBJECT IDENTIFIER ::= { an50ConfigWireless 19 } an50WrlsFrameSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the size of wireless frame (DL+RTD+UL) in micro seconds." ::= { an50ConfigScheduler 1 } an50WrlsMinBlockSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies a minimum number of bytes comprising transmitted block." ::= { an50ConfigScheduler 2 } an50WrlsDownlinkSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the size of downlink sub-frame in micro seconds." ::= { an50ConfigScheduler 3 } an50WrlsRoundTripDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the round trip delay in micro seconds." ::= { an50ConfigScheduler 4 } an50WrlsAdaptiveDLSize OBJECT-TYPE SYNTAX INTEGER { off (1), -- adaptive downlink size disabled on (2) -- adaptive downlink size enabled } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies if adaptive downlink size is enabled or disabled." ::= { an50ConfigScheduler 5 } an50WrlsExtSyncronize OBJECT-TYPE SYNTAX INTEGER { off (1), -- external synchronization disabled on (2) -- external synchronization enabled } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies if external synchronization is enabled or disabled." ::= { an50ConfigScheduler 6 } an50WrlsMaximumDistance OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the maximum distance between base station and subscriber station in Km." ::= { an50ConfigScheduler 7 } an50WrlsRegistrationPeriod OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the number of frames between registration periods." ::= { an50ConfigScheduler 8 } -- -- Config Default Group -- an50ConfigDefGroup OBJECT IDENTIFIER ::= { an50ConfigWireless 20 } an50WrlsBroadcastDLCIR OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the broadcast downlink commited rate in kb/s." ::= { an50ConfigDefGroup 1 } an50WrlsBroadcastDLPIR OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the broadcast downlink peak rate in kb/s." ::= { an50ConfigDefGroup 2 } an50WrlsDFSAction OBJECT-TYPE SYNTAX INTEGER { none (1), -- none txDisabled(2), -- transmission disabled changeFreq(3) -- change frequency } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the action taken when another system is detected on the same frequency" ::= { an50ConfigWireless 21 } an50WrlsAntennaGain OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Antenna Gain in dB." ::= { an50ConfigWireless 22 } an50WrlsATPEnabled OBJECT-TYPE SYNTAX INTEGER { no (1), -- automatic transmitted power control disabled yes(2) -- automatic transmitted power control enabled } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies if the Automatic Transmitted Power Control is enabled" ::= { an50ConfigWireless 23 } -- -- Performance Data Group -- an50ResetStatistics OBJECT-TYPE SYNTAX INTEGER { donothing(1), -- do not reset the performance statistics reset(2) -- reset the performance statistics } ACCESS read-write STATUS mandatory DESCRIPTION "A value of reset(2) resets the performance statistics on the AN-50, a value of donothing(1) does nothing." ::= { an50Pm 1 } -- -- Ethernet Performance Data Group -- an50PmEther OBJECT IDENTIFIER ::= { an50Pm 2 } an50PmEtherRxPackets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of ethernet packets successfully received by the local system." ::= { an50PmEther 1 } an50PmEtherRxPacketsErr OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of ethernet packet errors received by the local system." ::= { an50PmEther 2 } an50PmEtherTxPackets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Ethernet packets transmitted by the local system." ::= { an50PmEther 3 } an50PmEtherTxPacketsErr OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Ethernet error packets transmitted by the local system." ::= { an50PmEther 4 } an50PmEtherRxPacketsDisc OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of ethernet packets discarded by receiver." ::= { an50PmEther 5 } an50PmEtherTxPacketsDisc OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of ethernet packets discarded by transmitter." ::= { an50PmEther 6 } -- -- Wireless Performance Data Group -- an50PmWrls OBJECT IDENTIFIER ::= { an50Pm 3 } an50PmWrlsRxSigMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the minimum received signal strength measured since the last SNMP update." ::= { an50PmWrls 1 } an50PmWrlsRxSigMean OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the average received signal strength measured since the last SNMP update." ::= { an50PmWrls 2 } an50PmWrlsRxSigMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the maximum received signal strength measured since the last SNMP update" ::= { an50PmWrls 3 } an50PmWrlsAvgSinAdr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the average signal to noise ratio measured since the last SNMP update. The ratio is based on the digital information provided from the output of the AtoD converter." ::= { an50PmWrls 4 } an50PmWrlsRxPackets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of packets received over the air from the remote terminal." ::= { an50PmWrls 5 } an50PmWrlsRxPacketsRetx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of packets retransmitted over the air from the remoter terminal." ::= { an50PmWrls 6 } an50PmWrlsRxPacketsDisc OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of packets, originating from the remote terminal lost over the air due to degradation in the RF link." ::= { an50PmWrls 7 } an50PmWrlsTxPackets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of wireless packets (including Ethernet frames and error correction bytes) transmitted over the air by the local terminal." ::= { an50PmWrls 8} an50PmWrlsTxPacketsRetx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of packets retransmitted over the air by the local terminal. The retransmission scheme is based on the Acknowledge/Request (ARQ) algorithm that detects when packets are lost and makes a request to the MAC scheduler to repeat transmission of the lost packets." ::= { an50PmWrls 9} an50PmWrlsTxPacketsDisc OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the total number of packets lost over the air due to degradation in the RF link." ::= { an50PmWrls 10} an50PmWrlsCalcDst OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the calculated link distance." ::= { an50PmWrls 11} -- -- Software Upgrade Group -- an50Sw OBJECT IDENTIFIER ::= { an50Config 3 } an50SwServer OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The address of the TFTP server used for software upgrades. If the address of the TFTP server is unknown, return 0.0.0.0." ::= { an50Sw 1 } an50SwFilename OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "The file name of the software image to be loaded into this device." ::= { an50Sw 2 } an50SwAdminStatus OBJECT-TYPE SYNTAX INTEGER { noUpgrade(1), -- upgrade(2) -- download TFTP software image using an50SwFilename } ACCESS read-write STATUS mandatory DESCRIPTION "If set to upgrade(2), the device will initiate a TFTP software image download using an50SwFilename. If the download process is interrupted by a reset or power failure, the device will load the previous image. If set to noUpgrade(1), the device will revert to the previous version of the software. At initial startup, this object has the default value of noUpgrade(1)." ::= { an50Sw 3 } an50SwOperStatus OBJECT-TYPE SYNTAX INTEGER { inProgress(1), -- TFTP download in progress completeSuccess(2), -- TFTP download successful failed(3), -- TFTP download failed other(4) -- TFTP download } ACCESS read-only STATUS mandatory DESCRIPTION " This object shows the download status. inProgress(1) indicates that a TFTP download is underway completeSuccess(2) indicates that the last software upgrade was successful failed(3) indicates that the last attempted download failed, ordinarily due to TFTP timeout." ::= { an50Sw 4 } an50SwCurrentVers OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The software version currently operating in this device's flash. This object should be in the syntax used by the individual vendor to identify software versions. If it is not applicable, this MUST contain an empty string." ::= { an50Sw 5 } an50SwOtherVers OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The software version in the secondary flash. This object should be in the syntax used by the individual vendor to identify software versions. If it is not applicable, this MUST contain an empty string." ::= { an50Sw 6 } -- -- Traps Group. -- an50SysLastTrapTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of system.sysUpTime when the last trap was generated. If no traps have been generated since the last reset, this attribute has a value of 0. No trap is issued as a result of a change to this value." ::= { an50Trap 1 } an50TftpFailTrap TRAP-TYPE ENTERPRISE redline VARIABLES { an50SwServer, an50SwFilename, an50SwAdminStatus, an50SwOperStatus, an50SysLastTrapTime } DESCRIPTION "An event to report the failure of a Software Download." ::= 1 an50TftpSuccessTrap TRAP-TYPE ENTERPRISE redline VARIABLES { an50SwServer, an50SwFilename, an50SwAdminStatus, an50SwOperStatus, an50SysLastTrapTime } DESCRIPTION "An event to report the success of a Software Download." ::= 2 an50PswdChangeFailTrap TRAP-TYPE ENTERPRISE redline VARIABLES { an50SysLastTrapTime } DESCRIPTION "An event to report the failure of a password change." ::= 3 an50FirmwareConfigFailTrap TRAP-TYPE ENTERPRISE redline VARIABLES { an50SysLastTrapTime } DESCRIPTION "An event to report the failure of a firmware config." ::= 4 an50EepromCorruptedTrap TRAP-TYPE ENTERPRISE redline VARIABLES { an50SysLastTrapTime } DESCRIPTION "An event to report the corruption of the EEPROM." ::= 5 an50PowerSupplyFailureTrap TRAP-TYPE ENTERPRISE redline VARIABLES { an50SysLastTrapTime } DESCRIPTION "An event to report the power supply failure." ::= 6 an50SaveConfigTrap TRAP-TYPE ENTERPRISE redline VARIABLES { an50SysLastTrapTime } DESCRIPTION "An event to report the saving of configuration" ::= 7 an50ModifiedIDTrap TRAP-TYPE ENTERPRISE redline VARIABLES { an50pmpLastModifiedCID, an50SysLastTrapTime } DESCRIPTION "An event to report the modification in the configuration of a CID" ::= 8 an50pmpRegistrationMissed TRAP-TYPE ENTERPRISE redline VARIABLES { an50pmpLastMissedSsMacAddress, an50SysLastTrapTime } DESCRIPTION "An event to report the missing of the registration by a AN50 Subscriber to one BS.This trap is sent by the BS and contains the MAC address of the SS missing the registration" ::= 9 an50pmpRegistrationSuccessful TRAP-TYPE ENTERPRISE redline VARIABLES { an50pmpLastRegisteredSsMacAddress, an50SysLastTrapTime } DESCRIPTION "An event to report the successful registration of an AN50 Subscriber to BS. This trap is sent by the BS and contains the MAC address of the newly registered SS" ::= 10 an50DFSEvent TRAP-TYPE ENTERPRISE redline VARIABLES { an50SysLastTrapTime } DESCRIPTION "An event to report a dynamic frequency selection (DFS) event in AN50" ::= 11 an50MaxCid OBJECT-TYPE SYNTAX INTEGER (1 .. 1024) ACCESS read-only STATUS mandatory DESCRIPTION "The object contains the maximum number of CID for this equipment" ::= { an50LinkPmp 1 } an50LinkCurrentAvailId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current available ID in the Links table that is queried by NMS before creating a new row in Link Table" ::= { an50LinkPmp 2 } END