-- File: RAISECOM-OPCOM3500-RCRMC-MIB.my -- Changes: -- author:Wang H.L. --remote RC601VC,RC601VE,RC501,RC511FE,RC511-4FE -- RCRMC: RaiseCom Optical Tranceiver Series RAISECOM-OPT-REMOTE-RMC-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE,Integer32,Counter32 FROM SNMPv2-SMI DisplayString,TruthValue FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF rcNotifsTrapLocation FROM RAISECOM-NOTIFICATION-MIB optSysModules FROM RAISECOM-BASE-MIB RcOptModuleType, RcOptIfModuleType FROM RAISECOM-OPTICAL-MODULE-TYPE-MIB rcEntPhysicalID FROM RAISECOM-OPTICAL-ENTITY-MIB; raisecomOptRemoteRmcMib MODULE-IDENTITY LAST-UPDATED "1303071705Z" ORGANIZATION "RaiseCom Technology CO.,LTD" CONTACT-INFO " www.raisecom.com " DESCRIPTION "MIB for opcom3500 remote rc equipment." REVISION "0506130000Z" DESCRIPTION "" REVISION "0707160000Z" DESCRIPTION " 1.add rcRemoteRmcReqInfo by Liu.X.M. " REVISION "0905110000Z" DESCRIPTION " 1.add rcRemoteRmcLPBBeing INTEGER, rcRemoteRmcLPBInsideOutside INTEGER, rcRemoteRmcLPBMacAddrExch INTEGER, rcRemoteRmcLPBCrcRecal INTEGER, rcRemoteRmcLPBUtility INTEGER, rcRemoteRmcLPBFrameLength INTEGER, rcRemoteRmcLPBTime INTEGER rcRemoteRmcAdminCmd增加了2个命令项 fxloopbackexternal(5), fxloopbackinternal(6) by zhuleilei " REVISION "0906080000Z" DESCRIPTION " 1.add rcRemoteRmcQoSEnable INTEGER, rcRemoteRmcQueuesPolicy INTEGER, rcRemoteRmcQoSPolicy INTEGER, rcRemoteRmcBaseCOS INTEGER rcRemoteRmcEthFePriority INTEGER rcRemoteRmcVLANIndex INTEGER, rcRemoteRmcVLANStatus INTEGER, rcRemoteRmcVID INTEGER, rcRemoteRmcVLANMember INTEGER rcRemoteRmcVlantype增加了枚举值 tagvlan(3) rcRemoteRmcAdminCmd增加了1个命令项 versionnotice(7)--删掉了 by huxuehai " REVISION "2010030300Z" DESCRIPTION " 根据评审意见调整了2010-2-8的顺序 1.rcRemoteRmcSystemEntry add rcRemoteRmcVersionInformation OCTET STRING, rcRemoteRmcDeviceMode INTEGER, rcRemoteRmcRemManage INTEGER, rcRemoteRmcRemotePowerDown INTEGER, rcRemoteRmcRemoteSeriousAlarm INTEGER, rcRemoteRmcOAMConnect INTEGER, rcRemoteRmcMacAging INTEGER, rcRemoteRmcQosCfgQueueWeight OCTET STRING, rRemoteRmcQosCosToQueueQueue OCTET STRING, rcRemoteRmcQinQDirection INTEGER, rcRemoteRmcQinQTagMode INTEGER, rcRemoteRmcQinQDtOuterVID INTEGER, rcRemoteRmcQinQDtOuterTpid INTEGER rcRemoteRmcMaxPktsLength增加了枚举值 length2k(3) length9k(4) rcRemoteRmcAdminCmd增加了1个命令项 fxoamloopback(7) syncStatustoCfg(8) rcRemoteRmcQueuesPolicy增加了枚举值 wrr(5) onespthreewrr(6) twosptwowrr(7) 2.rcRemoteRmcEthFxEntry add rcRemoteRmcEthFxAttribute INTEGER, rcRemoteRmcEthFxCosOverrideEn INTEGER, rcRemoteRmcEthFxDefCos INTEGER, rcRemoteRmcEthFxFlowControl INTEGER, rcRemoteRmcEthFxAutoNegotiate INTEGER, rcRemoteRmcEthFxSpeedStatus INTEGER, rcRemoteRmcEthFxDuplexStatus INTEGER, rcRemoteRmcEthFxLoopStatus INTEGER, rcRemoteRmcEthFxTxBandWidthControl INTEGER, rcRemoteRmcEthFxRxBandWidthControl INTEGER, rcRemoteRmcEthFxType INTEGER 3.rcRemoteRmcVLANEntry add rcRemoteRmcTrunkUntag INTEGER 4. 修改了编译错误 by wuyanxiong " REVISION "2010051300Z" DESCRIPTION " 增加 以太网统计时间戳 节点 rcRemoteRmcEthFxTimeStamp INTEGER by wuyanxiong " REVISION "2010052100Z" DESCRIPTION " 修改 rcRemoteRmcEthFxDownIsForSnmpShutdown 属性为read-write 且根据代码,修改注释 1:网管关闭,2:网管打开 by wuyanxiong " REVISION "2010060700Z" DESCRIPTION " 根据RC552-GEF-A需求增加节点 支持的SFP速率类型 rcRemoteRmcEthFxSFPSpeedType by wuyanxiong " REVISION "2010092000Z" DESCRIPTION " 1.rcRemoteRmcSystemEntry add rcRemoteRmcAdminCmd增加了枚举值 channeltestStart(9) channeltestOver(10) rcRemoteRmcQoSPolicy增加了枚举值 disable(3) rcRemoteRmcMAClearn INTEGER, rcRemoteRmcFaultPass INTEGER, rcRemoteRmcLPBResult INTEGER 2.rcRemoteRmcEthFeTable add rcRemoteRmcEthFeDefCos INTEGER, rcRemoteRmcEthFeAdminCmd INTEGER, rcRemoteRmcEthFeVCTStatus INTEGER, rcRemoteRmcEthFeVCTMDIPairResult OCTET STRING, rcRemoteRmcEthFeVCTMDIPairFaultDistance OCTET STRING, rcRemoteRmcEthFeTimeStamp INTEGER by hejuan " REVISION "201011250000Z" DESCRIPTION " 1.rcRemoteRmcSystemEntry add rcRemoteRmcRemotePowerDown修改了枚举值 powerdown(1) normal(2) by hejuan " REVISION "2011042000Z" DESCRIPTION " 1.rcRemoteRmcSystemEntry add rcRemoteRmcSerialNumber OCTET STRING 2.rcRemoteRmcEthFeSpeed rcRemoteRmcEthFeSpeedStatus增加了枚举值 speed1000(3) other(4) by hejuan " REVISION "201104131130Z" DESCRIPTION " 增加 RMC保护表rcRemoteRmcApsTable 包括成员: rcRemoteRmcAPSType rcRemoteRmcApsForceSwitch rcRemoteRmcApsActiveLine rcRemoteRmcApsRevertive by yangbintao " REVISION "201104191405Z" DESCRIPTION " 在RMC保护表rcRemoteRmcApsTable中添加 成员: 返回时间:rcRemoteRmcApsWaitToRestore by yangbintao " REVISION "201104271856Z" DESCRIPTION " 添加rcRemoteRmcAdminCmd命令节点值softreset(11) 添加成员rcRemoteRmcEthFxSpeed,用来配置速率 by yangbintao " REVISION "1107190000Z" DESCRIPTION " rcRemoteRmcEthFeTxBytes Integer32--> Counter64 rcRemoteRmcEthFeRxBytes Integer32--> Counter64 ----by hejuan " REVISION "1112230944Z" DESCRIPTION " add rcRemoteRmcRmdStatus ----by yangbintao " REVISION "1209281447Z" DESCRIPTION " add rcRemoteRmcDeviceLedStatus add rcRemoteRmcAlarmShieldStatus add rcRemoteRmcAlarmShieldConfig add rcRemoteRmcEthFeTxFaultFramesThreshold add rcRemoteRmcEthFeRxFaultFramesThreshold ----by lixun " REVISION "1303071705Z" DESCRIPTION " add rcRemoteRmcFlowControl add rcRemoteRmcFlowControlStatus ----by lixun " ::= { optSysModules 19 } --对象定义 rcRemoteRmcSysObjects OBJECT IDENTIFIER ::= { raisecomOptRemoteRmcMib 1 } rcRemoteRmcEth OBJECT IDENTIFIER ::= { raisecomOptRemoteRmcMib 2 } rcRemoteRmcNotifications OBJECT IDENTIFIER ::= { raisecomOptRemoteRmcMib 3 } rcRemoteRmcVLAN OBJECT IDENTIFIER ::= { raisecomOptRemoteRmcMib 5 } rcRemoteRmcAps OBJECT IDENTIFIER ::= { raisecomOptRemoteRmcMib 6 } -- 系统配置表 rcRemoteRmcSystemTable OBJECT-TYPE SYNTAX SEQUENCE OF RcRemoteRmcSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RCRemoteRmc System table." ::= { rcRemoteRmcSysObjects 1 } rcRemoteRmcSystemEntry OBJECT-TYPE SYNTAX RcRemoteRmcSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the rc system table. " INDEX { rcEntPhysicalID } ::= { rcRemoteRmcSystemTable 1 } RcRemoteRmcSystemEntry ::= SEQUENCE { rcRemoteRmcDeviceExist INTEGER, rcRemoteRmcDeviceDescr DisplayString, rcRemoteRmcDeviceType RcOptModuleType, rcRemoteRmcSysTemperature INTEGER, rcRemoteRmcSysVoltageStatus INTEGER, rcRemoteRmcVlantype INTEGER, rcRemoteRmcMaxPktsLength INTEGER, rcRemoteRmcAdminCmd INTEGER, rcRemoteRmcOpticalModuleType RcOptIfModuleType, rcRemoteRmcReqInfo INTEGER, rcRemoteRmcLPBBeing INTEGER, rcRemoteRmcLPBInsideOutside INTEGER, rcRemoteRmcLPBMacAddrExch INTEGER, rcRemoteRmcLPBCrcRecal INTEGER, rcRemoteRmcLPBUtility INTEGER, rcRemoteRmcLPBFrameLength INTEGER, rcRemoteRmcLPBTime INTEGER, rcRemoteRmcQoSEnable INTEGER, rcRemoteRmcQueuesPolicy INTEGER, rcRemoteRmcQoSPolicy INTEGER, rcRemoteRmcBaseCOS INTEGER, rcRemoteRmcVersionInformation OCTET STRING, rcRemoteRmcDeviceMode INTEGER, rcRemoteRmcRemManage INTEGER, rcRemoteRmcRemotePowerDown INTEGER, rcRemoteRmcRemoteSeriousAlarm INTEGER, rcRemoteRmcOAMConnect INTEGER, rcRemoteRmcMacAging INTEGER, rcRemoteRmcQosCfgQueueWeight OCTET STRING, rcRemoteRmcQosCosToQueueQueue OCTET STRING, rcRemoteRmcQinQDirection INTEGER, rcRemoteRmcQinQTagMode INTEGER, rcRemoteRmcQinQDtOuterVID INTEGER, rcRemoteRmcQinQDtOuterTpid INTEGER, rcRemoteRmcMAClearn INTEGER, rcRemoteRmcFaultPass INTEGER, rcRemoteRmcLPBResult INTEGER, rcRemoteRmcSerialNumber OCTET STRING, rcRemoteRmcRemManageStatus INTEGER, rcRemoteRmcDeviceLedStatus INTEGER, rcRemoteRmcAlarmShieldStatus INTEGER, rcRemoteRmcAlarmShieldConfig INTEGER, rcRemoteRmcFlowControl INTEGER, rcRemoteRmcFlowControlStatus INTEGER } rcRemoteRmcDeviceExist OBJECT-TYPE SYNTAX INTEGER { exist(1), notExist(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " 远端设备是否在位 " ::= { rcRemoteRmcSystemEntry 2 } rcRemoteRmcDeviceDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " 远端设备描述 " ::= { rcRemoteRmcSystemEntry 3 } rcRemoteRmcDeviceType OBJECT-TYPE SYNTAX RcOptModuleType MAX-ACCESS read-only STATUS current DESCRIPTION " 远端设备类型 " ::= { rcRemoteRmcSystemEntry 4 } rcRemoteRmcSysTemperature OBJECT-TYPE SYNTAX INTEGER (-25..125) MAX-ACCESS read-only STATUS current DESCRIPTION " 远端设备温度 " ::= { rcRemoteRmcSystemEntry 8 } rcRemoteRmcSysVoltageStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), toohigh(2), toolow(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " 远端设备电压状态 " ::= { rcRemoteRmcSystemEntry 9 } rcRemoteRmcVlantype OBJECT-TYPE SYNTAX INTEGER { portvlan(1), novlan(2), tagvlan(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " 远端设备Vlan的类型 " ::= { rcRemoteRmcSystemEntry 10 } rcRemoteRmcMaxPktsLength OBJECT-TYPE SYNTAX INTEGER { length1916(1), length1536(2), length2k(3), length9k(4) } MAX-ACCESS read-write STATUS current DESCRIPTION " 远端设备最大包长,若为其他,表示实际包长度值 " ::= { rcRemoteRmcSystemEntry 11 } rcRemoteRmcAdminCmd OBJECT-TYPE SYNTAX INTEGER { reset(1), reqInfoStart(2), reqInfoOver(3), ready(4), fxloopbackexternal(5), fxloopbackinternal(6), fxoamloopback(7), syncstatustocfg(8), channeltestStart(9), channeltestOver(10), softreset(11) } MAX-ACCESS read-write STATUS current DESCRIPTION " 远端设备命令字,每个设备都有自己固定的命令字 1:复位 ,2:开始查询信息,3:结束查询信息 4:就绪 5. 光口外环 6. 光口内环 其中2,3只有531,532, 552设备支持 5、6 只有552 支持 7.oam环回 8.同步板卡console口配置到板卡 注:防止网管下发配置覆盖console口的配置。要等console口配置生效,状态改变后进行同步。 9.网管通道环回测试 10.取消网管通道环回测试 注:9、10只有局端设备支持 11.软复位芯片,只有OPCOM200-OCPF支持 " ::= { rcRemoteRmcSystemEntry 12 } rcRemoteRmcOpticalModuleType OBJECT-TYPE SYNTAX RcOptIfModuleType MAX-ACCESS read-only STATUS current DESCRIPTION " 远端设备光模块类型。RC501,RC511,RC601,RC601E,RC5114FE,RC531,RC532中实现。 " ::= { rcRemoteRmcSystemEntry 13 } rcRemoteRmcReqInfo OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " 远端设备统计信息查询状态,只有531,532设备支持 " ::= { rcRemoteRmcSystemEntry 14 } rcRemoteRmcLPBBeing OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " 环回 是否正处于环回状态,只有RC552FE设备支持 " ::= { rcRemoteRmcSystemEntry 15 } rcRemoteRmcLPBInsideOutside OBJECT-TYPE SYNTAX INTEGER { internal(1), external(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 环回 光口外环还是光口内环,只有RC552FE设备支持 " ::= { rcRemoteRmcSystemEntry 16 } rcRemoteRmcLPBMacAddrExch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 环回 是否交换MAC地址,只有RC552FE设备支持 " ::= { rcRemoteRmcSystemEntry 17 } rcRemoteRmcLPBCrcRecal OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 环回 是否重新计算CRC,只有RC552FE设备支持 " ::= { rcRemoteRmcSystemEntry 18 } rcRemoteRmcLPBUtility OBJECT-TYPE SYNTAX INTEGER { utility100(1), utility10(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 环回 测试数据的速率值,只有RC552FE设备支持 " ::= { rcRemoteRmcSystemEntry 19 } rcRemoteRmcLPBFrameLength OBJECT-TYPE SYNTAX INTEGER { length1518(1), length64(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 环回 测试数据的帧长度,只有RC552FE设备支持 " ::= { rcRemoteRmcSystemEntry 20 } rcRemoteRmcLPBTime OBJECT-TYPE SYNTAX INTEGER { min1(1), min2(2), min4(3), min8(4), min15(5), min30(6), min60(7), frame2(18), frame5(19), frame10(20), frame20(21), frame50(22), frame100(23), end(32), start(33) } MAX-ACCESS read-write STATUS current DESCRIPTION " 环回 测试时间设置,只有RC552FE设备支持 " ::= { rcRemoteRmcSystemEntry 21 } rcRemoteRmcQoSEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " QOS使能设置 " ::= { rcRemoteRmcSystemEntry 22 } rcRemoteRmcQueuesPolicy OBJECT-TYPE SYNTAX INTEGER { strictPriority(1), weightedCycle10vs1(2), weightedCycle5vs1(3), weightedCycle2vs1(4), wrr(5), onespthreewrr(6), twosptwowrr(7) } MAX-ACCESS read-write STATUS current DESCRIPTION " 队列调度策略: 1:严格优先 2:加权循环(高:低)10:1; 3:加权循环(高:低)5:1; 4:加权循环(高:低)2:1; 5: 加权循环; 6:队列4绝对优先,队列3-1加权循环; 7:队列4-3绝对有限,队列2-1加权循环; " ::= { rcRemoteRmcSystemEntry 23 } rcRemoteRmcQoSPolicy OBJECT-TYPE SYNTAX INTEGER { portBased(1), cosBased(2), disable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " QOS策略: 1:基于端口; 2:基于COS; 3:cos禁止 " ::= { rcRemoteRmcSystemEntry 24 } rcRemoteRmcBaseCOS OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " COS界限,取值0~7 " ::= { rcRemoteRmcSystemEntry 25 } rcRemoteRmcVersionInformation OBJECT-TYPE SYNTAX OCTET STRING(SIZE (0..100)) MAX-ACCESS read-only STATUS current DESCRIPTION " rmc设备版本信息 透传mcu ASCII码 " ::={ rcRemoteRmcSystemEntry 26 } rcRemoteRmcDeviceMode OBJECT-TYPE SYNTAX INTEGER { master(1), slave(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " -- rmc设备主从模式 1:主; 2:从 " ::={ rcRemoteRmcSystemEntry 27 } rcRemoteRmcRemManage OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " -- rmc设备远端管理功能 1:使能;2:禁止 注:远端设备无效 " ::={ rcRemoteRmcSystemEntry 28 } rcRemoteRmcRemotePowerDown OBJECT-TYPE SYNTAX INTEGER { powerdown(1), normal(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " rmc远端设备掉电 1 Powerdown:掉电, 2 Normal:正常 注:远端设备无效 " ::={ rcRemoteRmcSystemEntry 29 } rcRemoteRmcRemoteSeriousAlarm OBJECT-TYPE SYNTAX INTEGER { nothappenned(1), happenned (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " -- rmc设备远端严重事件告警是否发生 1:没有发生;2:发生 注:远端设备无效 " ::={ rcRemoteRmcSystemEntry 30 } rcRemoteRmcOAMConnect OBJECT-TYPE SYNTAX INTEGER { unconnected(1), connect(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Udrmc设备OAM连接是否建立 1 没有建立连接; 2 建立连接; " ::={ rcRemoteRmcSystemEntry 31 } rcRemoteRmcMacAging OBJECT-TYPE SYNTAX INTEGER { normal-200s(1), accelerate-2s(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " -- MAC老化时间 1:正常(300s) 2:加速(2s) " ::={ rcRemoteRmcSystemEntry 32 } rcRemoteRmcQosCfgQueueWeight OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Queue 1 to 4 maps to the wrr weight, the weight value ranges from 0 to 55 |队列1权重值|队列2权重值|队列3权重值|队列4权重值|,每个队列权重值占用一个字节; " ::= { rcRemoteRmcSystemEntry 33 } rcRemoteRmcQosCosToQueueQueue OBJECT-TYPE SYNTAX OCTET STRING(SIZE(8)) MAX-ACCESS read-write STATUS current DESCRIPTION "COS from 0 to 7 maps to the queue id,the queue id ranges from 1 to 4." ::= { rcRemoteRmcSystemEntry 34} rcRemoteRmcQinQDirection OBJECT-TYPE SYNTAX INTEGER { clienttoline(1), linetoclient(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " --VLAN-TAG方向 1:CLIENT口到LINE口 2:LINE口到CLIENT口 " ::={ rcRemoteRmcSystemEntry 35 } rcRemoteRmcQinQTagMode OBJECT-TYPE SYNTAX INTEGER { transparent(1), singletag(2), doubletag(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " -- QinQ模式 1:透传; 2:单Tag; 3:双Tag " ::={ rcRemoteRmcSystemEntry 36 } rcRemoteRmcQinQDtOuterVID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " -- OuterTag VID 1~4094 " ::={ rcRemoteRmcSystemEntry 37 } rcRemoteRmcQinQDtOuterTpid OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " -- OuterTag TPID 1~0xfffe,16进制 " ::={ rcRemoteRmcSystemEntry 38 } rcRemoteRmcMAClearn OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " -- MAC地址学习功能 1:打开;2:关闭 " ::={ rcRemoteRmcSystemEntry 39 } rcRemoteRmcFaultPass OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " -- 故障转移功能功能 bit1:光口到电口 1:使能;0:禁止 bit0:电口到光口 1:使能;0:禁止 " ::={ rcRemoteRmcSystemEntry 40 } rcRemoteRmcLPBResult OBJECT-TYPE SYNTAX INTEGER { success(1), failure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " -- 网管通道环回测试结果 1:成功;2:失败 " ::={ rcRemoteRmcSystemEntry 41 } rcRemoteRmcSerialNumber OBJECT-TYPE SYNTAX OCTET STRING(SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION " rmc设备产品序列号 透传mcu ASCII码 " ::={ rcRemoteRmcSystemEntry 42 } rcRemoteRmcRemManageStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), abnormal(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " -- rmc设备远端管理指示灯状态 1:连接正常;2:连接异常 " ::={ rcRemoteRmcSystemEntry 43 } rcRemoteRmcDeviceLedStatus OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " -- rmc设备指示灯状态 BIT0:电源指示灯1 BTI1:电源指示灯2 BIT2:告警指示灯 以上各BIT值含义均为0熄灭;1点亮 " ::={ rcRemoteRmcSystemEntry 44 } rcRemoteRmcAlarmShieldStatus OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " -- rmc设备告警端子屏蔽状态 BIT0:温度告警 BIT1:光口LINK DOWN BIT2:电口LINK DOWN BIT3:电源电压超限告警 以上各BIT值含义均为0禁止屏蔽;1使能屏蔽 " ::={ rcRemoteRmcSystemEntry 45 } rcRemoteRmcAlarmShieldConfig OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " -- rmc设备告警端子屏蔽状态 BIT0:温度告警 BIT1:光口LINK DOWN BIT2:电口LINK DOWN BIT3:电源电压超限告警 以上各BIT值含义均为0禁止屏蔽;1使能屏蔽 " ::={ rcRemoteRmcSystemEntry 46 } rcRemoteRmcFlowControl OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " -- rmc设备流控配置 1:打开; 2:关闭 " ::={ rcRemoteRmcSystemEntry 47 } rcRemoteRmcFlowControlStatus OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " -- rmc设备流控配置 1:打开; 2:关闭 " ::={ rcRemoteRmcSystemEntry 48 } ---------------------------------------------------------------------------- ------------------RCRemoteRmc FX table ---------------------------------------------------------------------------- rcRemoteRmcEthFxTable OBJECT-TYPE SYNTAX SEQUENCE OF RcRemoteRmcEthFxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RCRemoteRmc FX Port table." ::= { rcRemoteRmcEth 2 } rcRemoteRmcEthFxEntry OBJECT-TYPE SYNTAX RcRemoteRmcEthFxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the Fx Port config table. " INDEX { rcEntPhysicalID, rcRemoteRmcEthFxIndex } ::= { rcRemoteRmcEthFxTable 1 } RcRemoteRmcEthFxEntry ::= SEQUENCE { rcRemoteRmcEthFxIndex Integer32, rcRemoteRmcEthFxDescr DisplayString, rcRemoteRmcEthFxRLK INTEGER, rcRemoteRmcEthFxTLK INTEGER, rcRemoteRmcEthFxSD INTEGER, rcRemoteRmcEthFxTxPowerAbnormal INTEGER, rcRemoteRmcEthFxRxSensitiveAbnormal INTEGER, rcRemoteRmcEthFxLaserAbnormal INTEGER, rcRemoteRmcEthFxToFeFaultPass INTEGER, rcRemoteRmcEthFxALSEnable INTEGER, rcRemoteRmcEthFxDownIsForEthFeLinkDown TruthValue, rcRemoteRmcEthFxDownIsForEthFxNoRxSignal TruthValue, rcRemoteRmcEthFxDownIsForSnmpShutdown TruthValue, rcRemoteRmcEthFxTxBytes Counter32, rcRemoteRmcEthFxRxBytes Counter32, rcRemoteRmcEthFxTxFrames Counter32, rcRemoteRmcEthFxRxFrames Counter32, rcRemoteRmcEthFxTxFaultFrames Counter32, rcRemoteRmcEthFxRxFaultFrames Counter32, rcRemoteRmcEthFxTag INTEGER, rcRemoteRmcEthFxPVID INTEGER, rcRemoteRmcEthFxAttribute INTEGER, rcRemoteRmcEthFxCosOverrideEn INTEGER, rcRemoteRmcEthFxDefCos INTEGER, rcRemoteRmcEthFxFlowControl INTEGER, rcRemoteRmcEthFxAutoNegotiate INTEGER, rcRemoteRmcEthFxSpeedStatus INTEGER, rcRemoteRmcEthFxDuplexStatus INTEGER, rcRemoteRmcEthFxLoopStatus INTEGER, rcRemoteRmcEthFxTxBandWidthControl INTEGER, rcRemoteRmcEthFxRxBandWidthControl INTEGER, rcRemoteRmcEthFxType INTEGER, rcRemoteRmcEthFxTimeStamp INTEGER, rcRemoteRmcEthFxSFPSpeedType INTEGER, rcRemoteRmcEthFxSpeed INTEGER } rcRemoteRmcEthFxIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "光口索引 " ::= { rcRemoteRmcEthFxEntry 1 } rcRemoteRmcEthFxDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "接口描述 " ::= { rcRemoteRmcEthFxEntry 2 } rcRemoteRmcEthFxRLK OBJECT-TYPE SYNTAX INTEGER { linkup (1), linkdown (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "光口RLK " ::= { rcRemoteRmcEthFxEntry 3 } rcRemoteRmcEthFxTLK OBJECT-TYPE SYNTAX INTEGER { linkup(1), linkdown(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " 光口TLK " ::= { rcRemoteRmcEthFxEntry 4 } rcRemoteRmcEthFxSD OBJECT-TYPE SYNTAX INTEGER { normal (1), sd (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " 光口SD异常 " ::= { rcRemoteRmcEthFxEntry 5 } rcRemoteRmcEthFxTxPowerAbnormal OBJECT-TYPE SYNTAX INTEGER { normal (1), abnormal (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " 发送功率异常 " ::= { rcRemoteRmcEthFxEntry 6 } rcRemoteRmcEthFxRxSensitiveAbnormal OBJECT-TYPE SYNTAX INTEGER { normal (1), abnormal (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " 接收灵敏度异常 " ::= { rcRemoteRmcEthFxEntry 7 } rcRemoteRmcEthFxLaserAbnormal OBJECT-TYPE SYNTAX INTEGER { normal (1), abnormal (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " 光激光管工作异常 " ::= { rcRemoteRmcEthFxEntry 8 } rcRemoteRmcEthFxToFeFaultPass OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 远端设备FX到FE故障转移设置 " ::= { rcRemoteRmcEthFxEntry 9 } rcRemoteRmcEthFxALSEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 光口接收故障转移到发送使能 " ::= { rcRemoteRmcEthFxEntry 10 } rcRemoteRmcEthFxDownIsForEthFeLinkDown OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION " 如果该位置1,表明光口发送被关闭的原因是:当电口LINK-DOWN,并且光口到电口的故障转移功能被使能 否则该位置0 " ::= { rcRemoteRmcEthFxEntry 11 } rcRemoteRmcEthFxDownIsForEthFxNoRxSignal OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION " 如果该位置1,表明光口发送被关闭的原因是:当光口无接收信号,并且光口接收到光口发送的故障转移功能被使能 否则该位置0 " ::= { rcRemoteRmcEthFxEntry 12 } rcRemoteRmcEthFxDownIsForSnmpShutdown OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION " 网管关闭光口时为1,否则为2。 即 1:网管关闭,2:网管打开。 " ::= { rcRemoteRmcEthFxEntry 13 } rcRemoteRmcEthFxTxBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " 光端口发送字节数 " ::= { rcRemoteRmcEthFxEntry 14 } rcRemoteRmcEthFxRxBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " 光端口接收字节数 " ::= { rcRemoteRmcEthFxEntry 15 } rcRemoteRmcEthFxTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " 光端口发送帧数 " ::= { rcRemoteRmcEthFxEntry 16 } rcRemoteRmcEthFxRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " 光端口接收帧数 " ::= { rcRemoteRmcEthFxEntry 17 } rcRemoteRmcEthFxTxFaultFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " 光端口发送错误帧数 " ::= { rcRemoteRmcEthFxEntry 18 } rcRemoteRmcEthFxRxFaultFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " 光端口接收错误帧数 " ::= { rcRemoteRmcEthFxEntry 19 } rcRemoteRmcEthFxTag OBJECT-TYPE SYNTAX INTEGER { tag(1), untag(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 光端口输出帧是否带tag标识 " ::= { rcRemoteRmcEthFxEntry 20 } rcRemoteRmcEthFxPVID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " 光端口VID值,为无tag的包打tag标签时使用 " ::= { rcRemoteRmcEthFxEntry 21 } rcRemoteRmcEthFxAttribute OBJECT-TYPE SYNTAX INTEGER { access(1), trunk (2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 端口的VLAN属性 1:access 2:trunk " ::={ rcRemoteRmcEthFxEntry 22 } rcRemoteRmcEthFxCosOverrideEn OBJECT-TYPE SYNTAX INTEGER { enable(1), diable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 端口CoS 赋值使能 " ::={ rcRemoteRmcEthFxEntry 23 } rcRemoteRmcEthFxDefCos OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " 默认CoS值 (0~7) " ::={ rcRemoteRmcEthFxEntry 24 } rcRemoteRmcEthFxFlowControl OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 端口流控设置 " ::={ rcRemoteRmcEthFxEntry 25 } rcRemoteRmcEthFxAutoNegotiate OBJECT-TYPE SYNTAX INTEGER { enable(1), diable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 端口自协商设置 " ::={ rcRemoteRmcEthFxEntry 26 } rcRemoteRmcEthFxSpeedStatus OBJECT-TYPE SYNTAX INTEGER { speed10(1), speed100(2), speed1000(3), other(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " Eth端口速率 " ::={ rcRemoteRmcEthFxEntry 27 } rcRemoteRmcEthFxDuplexStatus OBJECT-TYPE SYNTAX INTEGER { full-duplex(1), half-duplex(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Eth双工模式 " ::={ rcRemoteRmcEthFxEntry 28 } rcRemoteRmcEthFxLoopStatus OBJECT-TYPE SYNTAX INTEGER { localoutsideloop(1), remoteoutsideloop(2), localinsideloop(3), oamloop(4), normal(100) } MAX-ACCESS read-only STATUS current DESCRIPTION " 端口的环回状态 1: 端口本地外环 2:端口远端外环 3:端口本地内环 4:OAM环 100:无环回 " ::={ rcRemoteRmcEthFxEntry 29 } rcRemoteRmcEthFxTxBandWidthControl OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " 以太网端口发送限定速率 " ::={ rcRemoteRmcEthFxEntry 30 } rcRemoteRmcEthFxRxBandWidthControl OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " 太网端口接收限定速率 " ::={ rcRemoteRmcEthFxEntry 31 } rcRemoteRmcEthFxType OBJECT-TYPE SYNTAX INTEGER { electrical(1), optical(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " 以太网端口的类型 1: electrical(1) 2: optical(2) " ::={ rcRemoteRmcEthFxEntry 32 } rcRemoteRmcEthFxTimeStamp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " 以太网流量统计上报时间戳 " ::={ rcRemoteRmcEthFxEntry 33 } rcRemoteRmcEthFxSFPSpeedType OBJECT-TYPE SYNTAX INTEGER { speed-1000M(1), speed-auto(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " 以太网端口支持的SFP速率类型 1:1000M 2:自协商接口 " ::={ rcRemoteRmcEthFxEntry 34 } rcRemoteRmcEthFxSpeed OBJECT-TYPE SYNTAX INTEGER { speed10(1), speed100(2), speed1000(3), other(4) } MAX-ACCESS read-write STATUS current DESCRIPTION " Eth端口速率配置 " ::={ rcRemoteRmcEthFxEntry 35 } ---------------------------------------------------------------------------- ------------------RCRemoteRmc FE table ---------------------------------------------------------------------------- -- Fe Current table rcRemoteRmcEthFeTable OBJECT-TYPE SYNTAX SEQUENCE OF RcRemoteRmcEthFeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RCRemoteRmc Fe Port table." ::= { rcRemoteRmcEth 1 } rcRemoteRmcEthFeEntry OBJECT-TYPE SYNTAX RcRemoteRmcEthFeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the Fe Port config table. " INDEX { rcEntPhysicalID, rcRemoteRmcEthFeIndex } ::= { rcRemoteRmcEthFeTable 1 } RcRemoteRmcEthFeEntry ::= SEQUENCE { rcRemoteRmcEthFeIndex Integer32, rcRemoteRmcEthFeDescr DisplayString, rcRemoteRmcEthFeLinkStatus INTEGER, rcRemoteRmcEthFeShutDown INTEGER, rcRemoteRmcEthFeAutoNegotiate INTEGER, rcRemoteRmcEthFeSpeed INTEGER, rcRemoteRmcEthFeSpeedStatus INTEGER, rcRemoteRmcEthFeDuplex INTEGER, rcRemoteRmcEthFeDuplexStatus INTEGER, rcRemoteRmcEthFeToFxFaultPass INTEGER, rcRemoteRmcEthFeTxBandWidthControl INTEGER, rcRemoteRmcEthFeRxBandWidthControl INTEGER, rcRemoteRmcEthFeTxBytes Counter64, rcRemoteRmcEthFeRxBytes Counter64, rcRemoteRmcEthFeTxFrames Counter32, rcRemoteRmcEthFeRxFrames Counter32, rcRemoteRmcEthFeTxFaultFrames Counter32, rcRemoteRmcEthFeRxFaultFrames Counter32, rcRemoteRmcEthFeDownIsForReEthfeFault TruthValue, rcRemoteRmcEthFeDownIsForEthFxFault TruthValue, rcRemoteRmcEthFeTag INTEGER, rcRemoteRmcEthFePVID INTEGER, rcRemoteRmcEthFePriority INTEGER, rcRemoteRmcEthFeDefCos INTEGER, rcRemoteRmcEthFeAdminCmd INTEGER, rcRemoteRmcEthFeVCTStatus INTEGER, rcRemoteRmcEthFeVCTMDIPairResult OCTET STRING, rcRemoteRmcEthFeVCTMDIPairFaultDistance OCTET STRING, rcRemoteRmcEthFeTimeStamp INTEGER, rcRemoteRmcEthFeTxFaultFramesThreshold INTEGER, rcRemoteRmcEthFeRxFaultFramesThreshold INTEGER } rcRemoteRmcEthFeIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " 以太网电口端口索引 " ::= { rcRemoteRmcEthFeEntry 1 } rcRemoteRmcEthFeDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " 以太网电口端口描述 " ::= { rcRemoteRmcEthFeEntry 2 } rcRemoteRmcEthFeLinkStatus OBJECT-TYPE SYNTAX INTEGER{ linkup(1), linkdown(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " 以太网电口的link状态 " ::= { rcRemoteRmcEthFeEntry 3 } rcRemoteRmcEthFeShutDown OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Eth端口关闭 " ::= { rcRemoteRmcEthFeEntry 4 } rcRemoteRmcEthFeAutoNegotiate OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Eth自协商设置,rc601不支持 " ::= { rcRemoteRmcEthFeEntry 5 } rcRemoteRmcEthFeSpeed OBJECT-TYPE SYNTAX INTEGER{ speed10(1), speed100(2), speed1000(3), other(4) } MAX-ACCESS read-write STATUS current DESCRIPTION " Eth端口速率设置,rc601不支持 " ::= { rcRemoteRmcEthFeEntry 6 } rcRemoteRmcEthFeSpeedStatus OBJECT-TYPE SYNTAX INTEGER{ speed10(1), speed100(2), speed1000(3), other(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " Eth端口速率 " ::= { rcRemoteRmcEthFeEntry 7 } rcRemoteRmcEthFeDuplex OBJECT-TYPE SYNTAX INTEGER { full-duplex(1), half-duplex(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Eth双工模式设置, rc601不支持 " ::= { rcRemoteRmcEthFeEntry 8 } rcRemoteRmcEthFeDuplexStatus OBJECT-TYPE SYNTAX INTEGER { full-duplex(1), half-duplex(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Eth双工模式 " ::= { rcRemoteRmcEthFeEntry 9 } rcRemoteRmcEthFeToFxFaultPass OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 远端设备FE到FX故障转移设置,所有的设备都不支持,现在只支持FX到FE的故障转移 " ::= { rcRemoteRmcEthFeEntry 10 } rcRemoteRmcEthFeTxBandWidthControl OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " 远端设备以太网端口接收限定速率: (n * value;n = 0,1,2....., rc511-4FE,rc5322FE,value = 32kb/s,rc531FE,rc532FE,value = 64kb/s). " ::= { rcRemoteRmcEthFeEntry 11 } rcRemoteRmcEthFeRxBandWidthControl OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " 远端设备以太网端口接收限定速率: (n * value;n = 0,1,2....., rc511-4FE,rc5322FE,value = 32kb/s,rc531FE,rc532FE,value = 64kb/s). " ::= { rcRemoteRmcEthFeEntry 12 } rcRemoteRmcEthFeTxBytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " fe端口发送字节流量统计 " ::= { rcRemoteRmcEthFeEntry 13 } rcRemoteRmcEthFeRxBytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " fe端口接收字节流量统计 " ::= { rcRemoteRmcEthFeEntry 14 } rcRemoteRmcEthFeTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " fe端口发送帧流量统计 " ::= { rcRemoteRmcEthFeEntry 15 } rcRemoteRmcEthFeRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " fe端口接收流量统计 " ::= { rcRemoteRmcEthFeEntry 16 } rcRemoteRmcEthFeTxFaultFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " fe端口发送错误帧统计 " ::= { rcRemoteRmcEthFeEntry 17 } rcRemoteRmcEthFeRxFaultFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " fe端口接收错误帧统计 " ::= { rcRemoteRmcEthFeEntry 18 } rcRemoteRmcEthFeDownIsForReEthfeFault OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION " 如果该位置1,表明本地电口被关闭的原因是:当远端电口出现故障,并且光口到电口的故障转移功能被使能、 否则该位置0 " ::= { rcRemoteRmcEthFeEntry 19 } rcRemoteRmcEthFeDownIsForEthFxFault OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION " 如果该位置1,表明本地电口被关闭的原因是:当光口出现故障,并且光口到电口的故障转移功能被使能 否则该位置0 " ::= { rcRemoteRmcEthFeEntry 20 } rcRemoteRmcEthFeTag OBJECT-TYPE SYNTAX INTEGER{ tag(1), un-tag(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 设置TAG " ::= { rcRemoteRmcEthFeEntry 21 } rcRemoteRmcEthFePVID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " 设置以太网电口PVID值,为输出包打tag标识时使用 " ::= { rcRemoteRmcEthFeEntry 22 } rcRemoteRmcEthFePriority OBJECT-TYPE SYNTAX INTEGER { high(1), low(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 设置端口优先级 " ::= { rcRemoteRmcEthFeEntry 23 } rcRemoteRmcEthFeDefCos OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " 设置以太网电口default cos值(0-7) " ::= { rcRemoteRmcEthFeEntry 24 } rcRemoteRmcEthFeAdminCmd OBJECT-TYPE SYNTAX INTEGER { reset(1), VirtualCableTest(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 电口命令字 1:复位;2:电口线路诊断命令 " ::= { rcRemoteRmcEthFeEntry 25 } rcRemoteRmcEthFeVCTStatus OBJECT-TYPE SYNTAX INTEGER { none(1), in(2), over(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " 电口线路诊断状态 " ::= { rcRemoteRmcEthFeEntry 26 } rcRemoteRmcEthFeVCTMDIPairResult OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION " 线对1-4诊断结果 short(1),open(2),normal(3) |线对4结果|线对3结果|线对2结果|线对1结果| 每个线对结果占1个字节,最低位字节表示线对1结果 " ::= { rcRemoteRmcEthFeEntry 27 } rcRemoteRmcEthFeVCTMDIPairFaultDistance OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION " 线对1-4故障距离 |线对4|线对3|线对2|线对1| 每个线对故障距离占4个字节,最低位4个字节表示线对1故障距离,单位:m " ::= { rcRemoteRmcEthFeEntry 28 } rcRemoteRmcEthFeTimeStamp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " 电口流量统计上报时间戳 " ::= { rcRemoteRmcEthFeEntry 29 } rcRemoteRmcEthFeTxFaultFramesThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " 电口发送失败超限告警阈值配置 " ::= { rcRemoteRmcEthFeEntry 30 } rcRemoteRmcEthFeRxFaultFramesThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " 电口接收错误超限告警阈值配置 " ::= { rcRemoteRmcEthFeEntry 31 } rcRemoteRmcNotificationPrefix OBJECT IDENTIFIER ::= { rcRemoteRmcNotifications 0 } rcRemoteRmcVoltageTooHighTrap NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID } STATUS current DESCRIPTION " 远端收发器电压过高通知信号. " ::= { rcRemoteRmcNotificationPrefix 1301 } rcRemoteRmcVoltageTooHighTrapOk NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID } STATUS current DESCRIPTION " 远端收发器电压过高恢复通知信号. " ::= { rcRemoteRmcNotificationPrefix 1302 } rcRemoteRmcVoltageTooLowTrap NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID } STATUS current DESCRIPTION " 远端收发器电压过低通知信号. " ::= { rcRemoteRmcNotificationPrefix 1303 } rcRemoteRmcVoltageTooLowTrapOk NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID } STATUS current DESCRIPTION " 远端收发器电压过低恢复通知信号. " ::= { rcRemoteRmcNotificationPrefix 1304 } rcRemoteRmcEthFeLinkdownTrap NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID ,rcRemoteRmcEthFeIndex } STATUS current DESCRIPTION " 以太网电口linkdown通知信号. " ::= { rcRemoteRmcNotificationPrefix 1305 } rcRemoteRmcEthFeLinkupTrap NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID ,rcRemoteRmcEthFeIndex } STATUS current DESCRIPTION " 以太网电口linkup通知信号. " ::= { rcRemoteRmcNotificationPrefix 1306 } rcRemoteRmcEthFxRLinkdownTrap NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID ,rcRemoteRmcEthFxIndex } STATUS current DESCRIPTION " 以太网光口接收linkdown通知信号. " ::= { rcRemoteRmcNotificationPrefix 1307 } rcRemoteRmcEthFxRLinkupTrap NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID ,rcRemoteRmcEthFxIndex } STATUS current DESCRIPTION " 以太网光口接收linkup通知信号. " ::= { rcRemoteRmcNotificationPrefix 1308 } rcRemoteRmcEthFxTLinkdownTrap NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID ,rcRemoteRmcEthFxIndex } STATUS current DESCRIPTION " 以太网光口发送linkdown通知信号. " ::= { rcRemoteRmcNotificationPrefix 1309 } rcRemoteRmcEthFxTLinkupTrap NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID ,rcRemoteRmcEthFxIndex } STATUS current DESCRIPTION " 以太网光口发送linkup通知信号. " ::= { rcRemoteRmcNotificationPrefix 1310 } rcRemoteRmcEthFxSDTrap NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID ,rcRemoteRmcEthFxIndex } STATUS current DESCRIPTION " 以太网光口SD异常通知信号. " ::= { rcRemoteRmcNotificationPrefix 1311 } rcRemoteRmcEthFxSDTrapOk NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID ,rcRemoteRmcEthFxIndex } STATUS current DESCRIPTION " 以太网光口SD异常恢复通知信号. " ::= { rcRemoteRmcNotificationPrefix 1312 } rcRemoteRmcEthFxTxPowerAbnormalTrap NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID ,rcRemoteRmcEthFxIndex } STATUS current DESCRIPTION " 以太网光口发送功率异常通知信号. " ::= { rcRemoteRmcNotificationPrefix 1313 } rcRemoteRmcEthFxTxPowerAbnormalTrapOk NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID ,rcRemoteRmcEthFxIndex } STATUS current DESCRIPTION " 以太网光口发送功率正常通知信号. " ::= { rcRemoteRmcNotificationPrefix 1314 } rcRemoteRmcEthFxRxSensitiveAbnormalTrap NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID ,rcRemoteRmcEthFxIndex } STATUS current DESCRIPTION " 以太网光口接收灵敏度异常通知信号. " ::= { rcRemoteRmcNotificationPrefix 1315 } rcRemoteRmcEthFxRxSensitiveAbnormalTrapOk NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID ,rcRemoteRmcEthFxIndex } STATUS current DESCRIPTION " 以太网光口接收灵敏度正常通知信号. " ::= { rcRemoteRmcNotificationPrefix 1316 } rcRemoteRmcEthFxLaserAbnormalTrap NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID ,rcRemoteRmcEthFxIndex } STATUS current DESCRIPTION " 以太网光口光激光管工作异常异常通知信号. " ::= { rcRemoteRmcNotificationPrefix 1317 } rcRemoteRmcEthFxLaserAbnormalTrapOk NOTIFICATION-TYPE OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID ,rcRemoteRmcEthFxIndex } STATUS current DESCRIPTION " 以太网光口光激光管工作正常通知信号. " ::= { rcRemoteRmcNotificationPrefix 1318 } -- conformance information rcRmcConformance OBJECT IDENTIFIER ::= { raisecomOptRemoteRmcMib 4 } rcRmcGroups OBJECT IDENTIFIER ::= { rcRmcConformance 1 } rcRmcDevices OBJECT IDENTIFIER ::= { rcRmcConformance 2 } -- units of conformance rc501Objects OBJECT-GROUP OBJECTS { rcRemoteRmcDeviceExist, rcRemoteRmcDeviceDescr, rcRemoteRmcDeviceType, rcRemoteRmcSysTemperature, rcRemoteRmcSysVoltageStatus, rcRemoteRmcAdminCmd, rcRemoteRmcOpticalModuleType, rcRemoteRmcEthFeIndex, rcRemoteRmcEthFeDescr, rcRemoteRmcEthFeLinkStatus, rcRemoteRmcEthFeShutDown, rcRemoteRmcEthFeAutoNegotiate, rcRemoteRmcEthFeSpeed, rcRemoteRmcEthFeSpeedStatus, rcRemoteRmcEthFeDuplex, rcRemoteRmcEthFeDuplexStatus, rcRemoteRmcEthFxIndex, rcRemoteRmcEthFxDescr, rcRemoteRmcEthFxRLK, rcRemoteRmcEthFxTLK, rcRemoteRmcEthFxSD, rcRemoteRmcEthFxTxPowerAbnormal, rcRemoteRmcEthFxRxSensitiveAbnormal, rcRemoteRmcEthFxLaserAbnormal, rcRemoteRmcEthFxToFeFaultPass } STATUS current DESCRIPTION " rc501设备管理对象 " ::= { rcRmcGroups 1 } rc601VCObjects OBJECT-GROUP OBJECTS { rcRemoteRmcDeviceExist, rcRemoteRmcDeviceDescr, rcRemoteRmcDeviceType, rcRemoteRmcSysTemperature, rcRemoteRmcSysVoltageStatus, rcRemoteRmcAdminCmd, rcRemoteRmcOpticalModuleType, rcRemoteRmcEthFeIndex, rcRemoteRmcEthFeDescr, rcRemoteRmcEthFeLinkStatus, rcRemoteRmcEthFeShutDown, rcRemoteRmcEthFeSpeedStatus, rcRemoteRmcEthFeDuplexStatus, rcRemoteRmcEthFxIndex, rcRemoteRmcEthFxDescr, rcRemoteRmcEthFxRLK, rcRemoteRmcEthFxTLK, rcRemoteRmcEthFxSD, rcRemoteRmcEthFxToFeFaultPass } STATUS current DESCRIPTION " rc601VC设备管理对象 " ::= { rcRmcGroups 2 } rc601VEObjects OBJECT-GROUP OBJECTS { rcRemoteRmcDeviceExist, rcRemoteRmcDeviceDescr, rcRemoteRmcDeviceType, rcRemoteRmcSysTemperature, rcRemoteRmcSysVoltageStatus, rcRemoteRmcAdminCmd, rcRemoteRmcOpticalModuleType, rcRemoteRmcEthFeIndex, rcRemoteRmcEthFeDescr, rcRemoteRmcEthFeLinkStatus, rcRemoteRmcEthFeShutDown, rcRemoteRmcEthFeSpeedStatus, rcRemoteRmcEthFeDuplexStatus, rcRemoteRmcEthFxIndex, rcRemoteRmcEthFxDescr, rcRemoteRmcEthFxRLK, rcRemoteRmcEthFxTLK, rcRemoteRmcEthFxSD, rcRemoteRmcEthFxToFeFaultPass } STATUS current DESCRIPTION " rc601VE设备管理对象 " ::= { rcRmcGroups 3 } -- units of conformance rc511Objects OBJECT-GROUP OBJECTS { rcRemoteRmcDeviceExist, rcRemoteRmcDeviceDescr, rcRemoteRmcDeviceType, rcRemoteRmcSysTemperature, rcRemoteRmcSysVoltageStatus, rcRemoteRmcAdminCmd, rcRemoteRmcOpticalModuleType, rcRemoteRmcEthFeIndex, rcRemoteRmcEthFeDescr, rcRemoteRmcEthFeLinkStatus, rcRemoteRmcEthFeShutDown, rcRemoteRmcEthFeAutoNegotiate, rcRemoteRmcEthFeSpeed, rcRemoteRmcEthFeSpeedStatus, rcRemoteRmcEthFeDuplex, rcRemoteRmcEthFeDuplexStatus, rcRemoteRmcEthFxIndex, rcRemoteRmcEthFxDescr, rcRemoteRmcEthFxRLK, rcRemoteRmcEthFxTLK, rcRemoteRmcEthFxSD, rcRemoteRmcEthFxTxPowerAbnormal, rcRemoteRmcEthFxRxSensitiveAbnormal, rcRemoteRmcEthFxLaserAbnormal, rcRemoteRmcEthFxToFeFaultPass } STATUS current DESCRIPTION " rc511设备管理对象 " ::= { rcRmcGroups 4 } rc511-4FEObjects OBJECT-GROUP OBJECTS { rcRemoteRmcDeviceExist, rcRemoteRmcDeviceDescr, rcRemoteRmcDeviceType, rcRemoteRmcSysTemperature, rcRemoteRmcSysVoltageStatus, rcRemoteRmcMaxPktsLength, rcRemoteRmcAdminCmd, rcRemoteRmcOpticalModuleType, rcRemoteRmcEthFeIndex, rcRemoteRmcEthFeDescr, rcRemoteRmcEthFeLinkStatus, rcRemoteRmcEthFeShutDown, rcRemoteRmcEthFeAutoNegotiate, rcRemoteRmcEthFeSpeed, rcRemoteRmcEthFeSpeedStatus, rcRemoteRmcEthFeDuplex, rcRemoteRmcEthFeDuplexStatus, rcRemoteRmcEthFeTxBandWidthControl, rcRemoteRmcEthFeRxBandWidthControl, rcRemoteRmcEthFeTxBytes, rcRemoteRmcEthFeRxBytes, rcRemoteRmcEthFxIndex, rcRemoteRmcEthFxDescr, rcRemoteRmcEthFxRLK, rcRemoteRmcEthFxTLK, rcRemoteRmcEthFxSD, rcRemoteRmcEthFxToFeFaultPass } STATUS current DESCRIPTION " rc511-4FE设备管理对象 " ::= { rcRmcGroups 5 } rc531-FEObjects OBJECT-GROUP OBJECTS { rcRemoteRmcDeviceExist, rcRemoteRmcDeviceDescr, rcRemoteRmcDeviceType, rcRemoteRmcSysTemperature, rcRemoteRmcSysVoltageStatus, rcRemoteRmcAdminCmd, rcRemoteRmcOpticalModuleType, rcRemoteRmcEthFeIndex, rcRemoteRmcEthFeDescr, rcRemoteRmcEthFeLinkStatus, rcRemoteRmcEthFeShutDown, rcRemoteRmcEthFeAutoNegotiate, rcRemoteRmcEthFeSpeed, rcRemoteRmcEthFeSpeedStatus, rcRemoteRmcEthFeDuplex, rcRemoteRmcEthFeDuplexStatus, rcRemoteRmcEthFeTxBandWidthControl, rcRemoteRmcEthFeRxBandWidthControl, rcRemoteRmcEthFeTxBytes, rcRemoteRmcEthFeRxBytes, rcRemoteRmcEthFeTxFrames, rcRemoteRmcEthFeRxFrames, rcRemoteRmcEthFeTxFaultFrames, rcRemoteRmcEthFeRxFaultFrames, rcRemoteRmcEthFeDownIsForReEthfeFault, rcRemoteRmcEthFeDownIsForEthFxFault, rcRemoteRmcEthFxIndex, rcRemoteRmcEthFxDescr, rcRemoteRmcEthFxRLK, rcRemoteRmcEthFxTLK, rcRemoteRmcEthFxSD, rcRemoteRmcEthFxToFeFaultPass, rcRemoteRmcEthFxALSEnable, rcRemoteRmcEthFxDownIsForEthFeLinkDown, rcRemoteRmcEthFxDownIsForEthFxNoRxSignal } STATUS current DESCRIPTION " rc531-FE设备管理对象 " ::= { rcRmcGroups 6 } rc532-FEObjects OBJECT-GROUP OBJECTS { rcRemoteRmcDeviceExist, rcRemoteRmcDeviceDescr, rcRemoteRmcDeviceType, rcRemoteRmcSysTemperature, rcRemoteRmcSysVoltageStatus, rcRemoteRmcVlantype, rcRemoteRmcMaxPktsLength, rcRemoteRmcAdminCmd, rcRemoteRmcOpticalModuleType, rcRemoteRmcEthFeIndex, rcRemoteRmcEthFeDescr, rcRemoteRmcEthFeLinkStatus, rcRemoteRmcEthFeShutDown, rcRemoteRmcEthFeAutoNegotiate, rcRemoteRmcEthFeSpeed, rcRemoteRmcEthFeSpeedStatus, rcRemoteRmcEthFeDuplex, rcRemoteRmcEthFeDuplexStatus, rcRemoteRmcEthFeTxBandWidthControl, rcRemoteRmcEthFeRxBandWidthControl, rcRemoteRmcEthFeTxBytes, rcRemoteRmcEthFeRxBytes, rcRemoteRmcEthFeTxFrames, rcRemoteRmcEthFeRxFrames, rcRemoteRmcEthFeTxFaultFrames, rcRemoteRmcEthFeRxFaultFrames, rcRemoteRmcEthFeDownIsForReEthfeFault, rcRemoteRmcEthFeDownIsForEthFxFault, rcRemoteRmcEthFxIndex, rcRemoteRmcEthFxDescr, rcRemoteRmcEthFxRLK, rcRemoteRmcEthFxTLK, rcRemoteRmcEthFxSD, rcRemoteRmcEthFxToFeFaultPass, rcRemoteRmcEthFxALSEnable, rcRemoteRmcEthFxDownIsForEthFeLinkDown, rcRemoteRmcEthFxDownIsForEthFxNoRxSignal } STATUS current DESCRIPTION " rc532-FE设备管理对象 " ::= { rcRmcGroups 7 } notificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { rcRemoteRmcVoltageTooHighTrap, rcRemoteRmcVoltageTooHighTrapOk, rcRemoteRmcVoltageTooLowTrap, rcRemoteRmcVoltageTooLowTrapOk, rcRemoteRmcEthFeLinkdownTrap, rcRemoteRmcEthFeLinkupTrap, rcRemoteRmcEthFxRLinkdownTrap, rcRemoteRmcEthFxRLinkupTrap, rcRemoteRmcEthFxTLinkdownTrap, rcRemoteRmcEthFxTLinkupTrap, rcRemoteRmcEthFxSDTrap, rcRemoteRmcEthFxSDTrapOk, rcRemoteRmcEthFxTxPowerAbnormalTrap, rcRemoteRmcEthFxTxPowerAbnormalTrapOk, rcRemoteRmcEthFxRxSensitiveAbnormalTrap, rcRemoteRmcEthFxRxSensitiveAbnormalTrapOk, rcRemoteRmcEthFxLaserAbnormalTrap, rcRemoteRmcEthFxLaserAbnormalTrapOk } STATUS current DESCRIPTION "The collection of the notifications." ::= { rcRmcGroups 8 } -- compliance statements rc501-0x0c MODULE-COMPLIANCE STATUS current DESCRIPTION " rc501卡式收发器 " MODULE -- this module MANDATORY-GROUPS { rc501Objects,notificationsGroup } ::= { rcRmcDevices 0 } rc601VC-0x09 MODULE-COMPLIANCE STATUS current DESCRIPTION " rc601VC收发器 " MODULE -- this module MANDATORY-GROUPS { rc601VCObjects,notificationsGroup } ::= { rcRmcDevices 2 } rc601VE-0x6f MODULE-COMPLIANCE STATUS current DESCRIPTION " rc601VE收发器 " MODULE -- this module MANDATORY-GROUPS { rc601VEObjects,notificationsGroup } ::= { rcRmcDevices 3 } rc511Card-0x3e MODULE-COMPLIANCE STATUS current DESCRIPTION " rc511卡式收发器 " MODULE -- this module MANDATORY-GROUPS { rc511Objects,notificationsGroup } ::= { rcRmcDevices 4 } rc511Device-0x6c MODULE-COMPLIANCE STATUS current DESCRIPTION " rc511台式收发器 " MODULE -- this module MANDATORY-GROUPS { rc511Objects,notificationsGroup } ::= { rcRmcDevices 5 } rc511-4FE-0xfc05 MODULE-COMPLIANCE STATUS current DESCRIPTION " rc511-4FE收发器 " MODULE -- this module MANDATORY-GROUPS { rc511-4FEObjects,notificationsGroup } ::= { rcRmcDevices 6 } rc531-FE-0x48 MODULE-COMPLIANCE STATUS current DESCRIPTION " rc531-FE收发器 " MODULE -- this module MANDATORY-GROUPS { rc531-FEObjects,notificationsGroup } ::= { rcRmcDevices 7 } rc532-FE-0x4d MODULE-COMPLIANCE STATUS current DESCRIPTION " rc532-FE收发器 " MODULE -- this module MANDATORY-GROUPS { rc532-FEObjects,notificationsGroup } ::= { rcRmcDevices 8 } ---------------------------------------------------------------------------- ------------------RCRemoteRmc VLAN table ---------------------------------------------------------------------------- -- 系统配置表 rcRemoteRmcVLANTable OBJECT-TYPE SYNTAX SEQUENCE OF RcRemoteRmcVLANEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RCRemoteRmc VLAN table." ::= { rcRemoteRmcVLAN 1 } rcRemoteRmcVLANEntry OBJECT-TYPE SYNTAX RcRemoteRmcVLANEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the RRMC VLAN table. " INDEX { rcEntPhysicalID,rcRemoteRmcVLANIndex } ::= { rcRemoteRmcVLANTable 1 } RcRemoteRmcVLANEntry ::= SEQUENCE { rcRemoteRmcVLANIndex INTEGER, rcRemoteRmcVLANStatus INTEGER, rcRemoteRmcVID INTEGER, rcRemoteRmcVLANMember INTEGER, rcRemoteRmcTrunkUntag INTEGER } rcRemoteRmcVLANIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " VLAN索引,取值1~16 " ::= { rcRemoteRmcVLANEntry 1 } rcRemoteRmcVLANStatus OBJECT-TYPE SYNTAX INTEGER { activated(1), nonactivated(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " VLAN激活状态 " ::= { rcRemoteRmcVLANEntry 2 } rcRemoteRmcVID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " VLAN ID,取值1~4094 " ::= { rcRemoteRmcVLANEntry 3 } rcRemoteRmcVLANMember OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " bit31~0对应第32路~第1路EthFe口,第n位为1表示第n+1端口为该该VLAN成员。 目前RC511-4FEE1-REV-B设备只有4路EthFe。 例如:bit3=1,bit0=1,表示端口4和端口1为该VLAN的成员。 " ::= { rcRemoteRmcVLANEntry 4 } rcRemoteRmcTrunkUntag OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " Bit 31~0对应第32路~第1路端口。 例如:bit3=1,bit0=1,表示从端口4和端口1发出都去掉此VLAN TAG " ::= { rcRemoteRmcVLANEntry 5 } rcRemoteRmcApsTable OBJECT-TYPE SYNTAX SEQUENCE OF RcRemoteRmcApsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RCRemoteRmc Ptotect table." ::= { rcRemoteRmcAps 1 } rcRemoteRmcApsEntry OBJECT-TYPE SYNTAX RcRemoteRmcApsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the rc protect table. " INDEX { rcEntPhysicalID } ::= { rcRemoteRmcApsTable 1 } RcRemoteRmcApsEntry ::= SEQUENCE { rcRemoteRmcApsType INTEGER, rcRemoteRmcApsForceSwitch INTEGER, rcRemoteRmcApsActiveLine INTEGER, rcRemoteRmcApsRevertive INTEGER, rcRemoteRmcApsWaitToRestore INTEGER } rcRemoteRmcApsType OBJECT-TYPE SYNTAX INTEGER { onePlusOneProtectSwitch(1), oneForOneProtectSwitch(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 保护倒换模式,1+1 or 1:1 " ::= { rcRemoteRmcApsEntry 1 } rcRemoteRmcApsForceSwitch OBJECT-TYPE SYNTAX INTEGER { auto(1), toPriLine(2), toSecLine(3), reserved(4) } MAX-ACCESS read-write STATUS current DESCRIPTION " 线路侧倒换模式,自动,强制到主,强制到备,保留 " ::= { rcRemoteRmcApsEntry 2 } rcRemoteRmcApsActiveLine OBJECT-TYPE SYNTAX INTEGER { priChannel(1), secChannel(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " 当前工作通道,主通道,备通道 " ::= { rcRemoteRmcApsEntry 3 } rcRemoteRmcApsRevertive OBJECT-TYPE SYNTAX INTEGER { nonrevertive(1), revertive(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " 返回模式,非自动返回,自动返回 " ::= { rcRemoteRmcApsEntry 4 } rcRemoteRmcApsWaitToRestore OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " 返回时间0-255,以分钟为单位,默认为12分钟 " ::= { rcRemoteRmcApsEntry 5 } END