RAD-Pw-MIB DEFINITIONS ::= BEGIN -- It is RAD's intent to encourage the widespread use of -- this Specification in connection with the management of -- RAD products. RAD grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of RAD products. -- This Specification is supplied "as is," and RAD makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. IMPORTS InterfaceIndexOrZero FROM IF-MIB PerfCurrentCount, PerfIntervalCount FROM PerfHist-TC-MIB Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, IpAddress, Integer32, Gauge32, NOTIFICATION-TYPE FROM SNMPv2-SMI InetAddressType, InetAddress FROM INET-ADDRESS-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB IndexIntegerNextFree FROM DIFFSERV-MIB pwDescr FROM PW-STD-MIB MacAddress, RowStatus, DateAndTime, TruthValue FROM SNMPv2-TC rad FROM RAD-SMI-MIB alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason FROM RAD-GEN-MIB protectGroupLastSwitchReason FROM RAD-Protection-MIB; radPw MODULE-IDENTITY LAST-UPDATED "201507161121Z" -- July 16, 2015 ORGANIZATION "RAD Data Communications Ltd." CONTACT-INFO "System Department Email: mibs@rad.com Postal: RAD Data Communications Ltd. 24 Raoul Wallenberg St. Tel-Aviv 6971920 Israel Phone: +972-3-645-5421 Fax: +972-3-760-7844" DESCRIPTION "PW MIB." ::= { rad 14 } radPwNotifications OBJECT IDENTIFIER ::= { radPw 0 } radPwCfgObjects OBJECT IDENTIFIER ::= { radPw 1 } radPwPerfMonitoring OBJECT IDENTIFIER ::= { radPw 2 } radPwGenCfgObjects OBJECT IDENTIFIER ::= { radPwCfgObjects 1 } radPwPsnCfgObjects OBJECT IDENTIFIER ::= { radPwCfgObjects 2 } radPwServiceCfgObjects OBJECT IDENTIFIER ::= { radPwCfgObjects 3 } -- *** PW General Parameters *** pwGenTable OBJECT-TYPE SYNTAX SEQUENCE OF PwGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains general configuration for PW connection." ::= { radPwGenCfgObjects 1 } pwGenEntry OBJECT-TYPE SYNTAX PwGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is indexed by pwIdx, the value of which is equal to the same index that was created for the associated entry in the PW Table (in the PW-STD-MIB)- the pwIndex. An entry is created in this table by the agent for every entry in the pwTable." INDEX { pwIdx } ::= { pwGenTable 1 } PwGenEntry ::= SEQUENCE { pwIdx Unsigned32, pwGenPeerIdx Unsigned32, pwGenAttachmentCircuit InterfaceIndexOrZero, pwGenOutgoingInterface InterfaceIndexOrZero, pwGenOamMode INTEGER, pwGenOamType INTEGER, pwGenSequenceNumberField INTEGER, pwGenNextHopType INTEGER, pwGenNextHop Unsigned32, pwGenIpNextHop IpAddress, pwGenMacNextHop MacAddress, pwGenEnableVlanTag INTEGER, pwGenVlanId Unsigned32, pwGenVlanPriority Unsigned32, pwGenIpTos Unsigned32, pwGenSourceUdpPort Unsigned32, pwGenSubType INTEGER, pwGenSourceIpAddress IpAddress, pwGenSourceIpMask IpAddress, pwGenUdpMuxMethod INTEGER, pwGenOamStatus INTEGER, pwGenMismatchReason INTEGER, pwGenOamDelayThreshold Unsigned32, pwGencasFramesPerPacket Unsigned32, pwGenOamDelayThresholdFalling Unsigned32 } pwIdx OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of this table. The value for this object is equal to the value of pwIndex from the pwTable of PW-STD-MIB" ::= { pwGenEntry 1} pwGenPeerIdx OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Index of the Peer (as it is defined in the Peer Table), which terminated this PW." ::= { pwGenEntry 2 } pwGenAttachmentCircuit OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-write STATUS current DESCRIPTION "This is a unique index within the ifTable. It represents the attached circuit interface (e.g ATM VC, HDLC) attached to this PW connection (from service initiator side). A value of zero indicates an interface index that has yet to be determined. Once set, if the attached circuit is (for some reason) later removed, the agent should DELETE the associated PW rows. If the agent does not delete the rows, the agent MUST set this object to zero. This object is applicable only for device which translates Attachment Circuit to other logical interface. " ::= { pwGenEntry 3 } pwGenOutgoingInterface OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-write STATUS current DESCRIPTION "This is a unique index within the ifTable. It represents the outgoing interface (towards the PSN ) attached to this PW connection. This object is applicable only when the forwarding is done at layer 2 i.e. without routing. Applicable PSN types are MPLS and Ethernet (MEF8). A value of zero indicates an interface index that has yet to be determined, or it is not applicable. Once set, if the outgoing interface is (for some reason) later removed, the agent may DELETE the associated PW rows. If the agent does not delete the rows, the agent MUST set this object to zero. This object is applicable only for devices that allow manual configuration of outgoing interface." ::= { pwGenEntry 4 } pwGenOamMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This objects defines whether OAM will be enabled on this PW. notApplicable(1) value will be used when PW type does not support OAM." ::= { pwGenEntry 5 } pwGenOamType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), propietary (2), bfd (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This objects defines the failure detection mechanism used on this PW. BFD - Bidirectional Forwarding Detection notApplicable(1) value will be used when pwGenOamMode is notApplicable." ::= { pwGenEntry 6 } pwGenSequenceNumberField OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines whether processing of Sequence Number field (ATM cell encapsulation) will be done by device, on this PW." ::= { pwGenEntry 7 } pwGenNextHopType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), atmVc (2), bridgePort (3), ipV4 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates address type of the Next Hop. Not applicable for device with router." ::= { pwGenEntry 8 } pwGenNextHop OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Not applicable (=0) when pwMplsEgressTunnelNextHopType=notApplicable. When applicable, represents ATM VC, Bridge Port, according to pwMplsEgressTunnelNextHopType." ::= { pwGenEntry 9} pwGenIpNextHop OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines local Next Hop IP Address for this PW. 0.0.0.0 - means - not applicable. This object is applicable only when pwGenNextHopType=ipV4" ::= { pwGenEntry 10 } pwGenMacNextHop OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines local Next Hop MAC Address for this PW. 0:0:0:0:0:0 - means - not applicable. This object is applicable only when pwGenNextHopType=bridgePort" ::= { pwGenEntry 11 } pwGenEnableVlanTag OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables or disables a VLAN tag on every transmitted packet via this PW connection" ::= { pwGenEntry 12 } pwGenVlanId OBJECT-TYPE SYNTAX Unsigned32 (1..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the VLAN ID tag attached to every transmitted packet via this PW connection. This entry is applicable only if pwGenEnableVlanTag=enabled(3)." ::= { pwGenEntry 13 } pwGenVlanPriority OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the VLAN priority assigned to every transmitted packet via this PW connection. This entry is applicable only if pwGenEnableVlanTag=enabled(3)" ::= { pwGenEntry 14 } pwGenIpTos OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates TOS field value for PW having pwPsnType= ip(3)" ::= { pwGenEntry 15 } pwGenSourceUdpPort OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates source UDP port (1...65535) value for pw having pwPsnType= ip (3)" ::= { pwGenEntry 16 } pwGenSubType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), clockRecovery (2), clockDistribution (3), data (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the PW Sub Type (i.e. Sub Type of 'pwType' from 'pwTable'). For ACE-3000 devices: It is applicable only when pwType = basicCesPsn(21)." ::= { pwGenEntry 17 } pwGenSourceIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Source IP Address per PW" ::= { pwGenEntry 18 } pwGenSourceIpMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Source IP Mask per PW" ::= { pwGenEntry 19 } pwGenUdpMuxMethod OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), sourcePort (2), destinationPort (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This objects defines the method in which the UDP header is used to multiplex between different PWs, as follows: sourcePort - validate the destination port value and perform internal routing according to the source port (RAD's old implementation). destinationPort - the configured destination port, together with both the source and destination IP addresses, uniquely identifies the PW for the receiver (standard method). It is applicable only when pwPsnType= ip(3)." ::= { pwGenEntry 21 } pwGenOamStatus OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), connected (3), failure (4), validationFail (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This objects indicates the status of the PW OAM: disabled - the PW is shutdown and/or OAM is disabled for the PW. connected - OAM is enabled and is synchronized with the peer device. failure - OAM not synchronized with the peer and/or data failure. validationFail - configuration mismatch between local and remote devices." ::= { pwGenEntry 23 } pwGenMismatchReason OBJECT-TYPE SYNTAX INTEGER { tdmoipFrameFormat (1), tdmoipVersion (2), receivedEthernetFrame (3), receivedFrameLength (4), other (2147483647) } MAX-ACCESS read-only STATUS current DESCRIPTION " This object details the PW configuration mismatch." ::= { pwGenEntry 24 } pwGenOamDelayThreshold OBJECT-TYPE SYNTAX Unsigned32 UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This objects defines a Delay Threshold in microseconds when this value is exceeded an event is sent. (used as rising threshold) Rising threshold range of values is between 1-180 msec, default value is 180msec." ::= { pwGenEntry 27 } pwGencasFramesPerPacket OBJECT-TYPE SYNTAX Unsigned32 ( 1|2|3|4|5|6|7|8|12|16|24|32|40|48|56|64) MAX-ACCESS read-write STATUS current DESCRIPTION "This objects defines the Frames Per Packet: 4 - E1/T1 frames per packet, packetization delay of 0.5 m.s. 8 - E1/T1 frames per packet, packetization delay of 1 m.s. 12 - T1 frames per packet, packetization delay of 1.5 m.s (for SF this means no fragmentation) 16 - E1 frames per packet (no fragmentation), packetization delay of 2 m.s. 24 - T1 frames per packet (no fragmentation), packetization delay of 3 m.s." ::= { pwGenEntry 28 } pwGenOamDelayThresholdFalling OBJECT-TYPE SYNTAX Unsigned32 UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This objects defines a PW OAM Delay falling Threshold in microseconds units. When delay reach below this value, event is cleared. Falling threshold range of values is between 1-180 msec, default value is 180msec. Falling threshold must be equal or smaller then rising threshold" ::= { pwGenEntry 29 } pwGenTimeout OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Timeout period, measured in usec. This object is relevant only for ATM service." ::= { radPwGenCfgObjects 2 } pwGenMisorderWindowSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Window Size (in packets), in which the device will attempt to reorder packets. Packets having sequence number with gap greater than the Window Size - will not take part in the process. This object is relevant only for ATM service." ::= { radPwGenCfgObjects 3 } pwGenFixMisorderSupport OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines whether the process of reorder, within the Window Size (pwGenMisorderWindowSize), should be activated or not. This object is relevant only for ATM service." ::= { radPwGenCfgObjects 4 } pwGenLabelTable OBJECT-TYPE SYNTAX SEQUENCE OF PwGenLabelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines supported range of PW labels." ::= { radPwGenCfgObjects 5 } pwGenLabelEntry OBJECT-TYPE SYNTAX PwGenLabelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry in this table defines range of PW labels in the direction and type indicated by pwGenLabelType and pwGenLabelDirection." INDEX { pwGenLabelType, pwGenLabelDirection} ::= { pwGenLabelTable 1 } PwGenLabelEntry ::= SEQUENCE { pwGenLabelType INTEGER, pwGenLabelDirection INTEGER, pwGenLabelMinValue Unsigned32, pwGenLabelMaxValue Unsigned32 } pwGenLabelType OBJECT-TYPE SYNTAX INTEGER { static (2), dynamic(3) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object defines type of label." ::= { pwGenLabelEntry 1 } pwGenLabelDirection OBJECT-TYPE SYNTAX INTEGER { ingress (2), egress (3) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object defines PW direction." ::= { pwGenLabelEntry 2 } pwGenLabelMinValue OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines minimum value of PW labels, in the direction and type indicated by pwGenLabelType and pwGenLabelDirection." ::= { pwGenLabelEntry 3 } pwGenLabelMaxValue OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object define maximum value of PW labels, in the direction and type indicated by pwGenLabelType and pwGenLabelDirection." ::= { pwGenLabelEntry 4 } -- Peer Table peerTable OBJECT-TYPE SYNTAX SEQUENCE OF PeerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Peer Table" ::= { radPwGenCfgObjects 6 } peerEntry OBJECT-TYPE SYNTAX PeerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table." INDEX { peerIndex } ::= { peerTable 1 } PeerEntry ::= SEQUENCE { peerIndex Unsigned32, peerRowStatus RowStatus, peerAddressType InetAddressType, peerAddress InetAddress, peerName SnmpAdminString, peerNoOfUsages Unsigned32, peerTargeted INTEGER, peerNextHopAddressType InetAddressType, peerNextHopAddress InetAddress, peerAddressClass INTEGER, peerMacAddress MacAddress, peerRouterInstance Unsigned32 } peerIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object represents the Peer Index." ::= { peerEntry 1 } peerRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used for creating, modifying and deleting a row of this table." ::= { peerEntry 2 } peerAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "This object represents the Address Type of the Peer node. It should be set to 'unknown' if PE/PW maintenance protocol is not used and the address is unknown. The peer address can be an IP address or a MAC address. Since the standard TC (InetAddressType) supports only IP address types an additional object, peerAddressClass, is defined. The value of peerAddressClass indicates whether the relevant objects are peerAddressType+peerAddress or peerMacAddress." ::= { peerEntry 3 } peerAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This object represents the Peer node Address. of the PW/PE maintenance protocol entity. This object SHOULD contain a value of all zeroes if not applicable (peerAddrType is 'unknown')." ::= { peerEntry 4 } peerName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-create STATUS current DESCRIPTION "This object represents the Peer Name." ::= { peerEntry 5 } peerNoOfUsages OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of times this Peer is used (by PWs, Egress LSP Tunnels etc)." ::= { peerEntry 6 } peerTargeted OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates whether the Peer is configured as a Targeted Peer or not." ::= { peerEntry 7 } peerNextHopAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "This object represents the Address Type of the Peer Next Hop node. It should be set to 'unknown' if the address is unknown." ::= { peerEntry 8 } peerNextHopAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This object represents the Peer Next Hop node Address. This object SHOULD contain a value of all zeroes if not applicable (peerAddrType is 'unknown')." ::= { peerEntry 9 } peerAddressClass OBJECT-TYPE SYNTAX INTEGER { ip (2), mac (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines if the Peer address is given as an IP address or a MAC address. The value of peerAddressClass indicates whether the relevant objects are peerAddressType+peerAddress or peerMacAddress." DEFVAL {ip} ::= { peerEntry 10 } peerMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines the address of the peer node when layer 2 forwarding is used (MEF8)" ::= { peerEntry 11 } peerRouterInstance OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines the instance of the routing domain that this peer belongs to." DEFVAL {1} ::= { peerEntry 12 } -- *** PW PSN Parameters -- *** MPLS PSN type parameters *** radPwPsnCfgMpls OBJECT IDENTIFIER ::= { radPwPsnCfgObjects 1} -- MPLS Type PSN Configuration Table pwMplsCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PwMplsCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains MPLS PSN related configuration for PW connection." ::= { radPwPsnCfgMpls 1 } pwMplsCfgEntry OBJECT-TYPE SYNTAX PwMplsCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is indexed by pwIdx, the value of which is equal to the same index that was created for the associated entry in the PW Table (in the PW-STD-MIB)- the pwIndex. An entry is created in this table by the agent for every entry in the pwGenTable with a pwGenPsnType=MPLS." INDEX { pwIdx } ::= { pwMplsCfgTable 1 } PwMplsCfgEntry ::= SEQUENCE { pwMplsCfgIngressTunnel Unsigned32, pwMplsCfgEgressTunnel Unsigned32 } pwMplsCfgIngressTunnel OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object points to an entry of pwMplsIngressTunnelTable. Its value is equal to pwMplsIngressTunnelIndex" ::= { pwMplsCfgEntry 1} pwMplsCfgEgressTunnel OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object points to an entry of pwMplsEgressTunnelTable. Its value is equal to pwMplsEgressTunnelIndex." ::= { pwMplsCfgEntry 2 } -- *** ETH PSN Type tables were removed -- since there's no ETH PSN. -- VLAN parameters were replaced by -- pwGenEnableVlanTag, pwGenVlanId,pwGenVlanPriority -- *** IP PSN Type tables were removed. -- *** Service Parameters *** -- *** TDM over IP / CESoPSN Service radPwServiceCfgTDMoIp OBJECT IDENTIFIER ::= { radPwServiceCfgObjects 1} pwTDMoIpTable OBJECT-TYPE SYNTAX SEQUENCE OF PwTDMoIpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains TDMoIP Service related configuration for PW connection." ::= { radPwServiceCfgTDMoIp 1 } pwTDMoIpEntry OBJECT-TYPE SYNTAX PwTDMoIpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is indexed by pwIdx, the value of which is equal to the same index that was created for the associated entry in the PW Table (in the PW-STD-MIB)- the pwIndex. An entry is created in this table by the agent for every entry in the pwTable with a pwType equal to one of the following: e1Satop(17), t1Satop(18), e3Satop(19), t3Satop(20), basicCesPsn(21), basicTdmIp(22), tdmCasCesPsn(23), tdmCasTdmIp(24)." INDEX { pwIdx } ::= { pwTDMoIpTable 1 } PwTDMoIpEntry ::= SEQUENCE { pwTDMoIpCfgIndex Unsigned32 } pwTDMoIpCfgIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Index to TDMoIP table below. Multiple TDMoIP PWs MAY share a single pwTDMoIpCfgEntry" ::= { pwTDMoIpEntry 1} -- *** TDM over IP / CESoPSN Service configuration table pwTDMoIpIndexNext OBJECT-TYPE SYNTAX IndexIntegerNextFree MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains an unused value for pwTDMoIpCfgTableIndex, or a zero to indicate that none exist. Negative values are not allowed, as they do not correspond to valid values of pwTDMoIpCfgTableIndex." ::= { radPwServiceCfgTDMoIp 2 } pwTDMoIpCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PwTDMoIpCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains TDM over IP service configuration for PW connection." ::= { radPwServiceCfgTDMoIp 3 } pwTDMoIpCfgEntry OBJECT-TYPE SYNTAX PwTDMoIpCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is indexed by pwIdx, the value of which is equal to the same index that was created for the associated entry in the PW Table (in the PW-STD-MIB)- the pwIndex. An entry is created in this table by the agent for every entry in the pwTable with a pwType equal to one of the following: e1Satop(17), t1Satop(18), e3Satop(19), t3Satop(20), basicCesPsn(21), basicTdmIp(22), tdmCasCesPsn(23), tdmCasTdmIp(24)." INDEX { pwTDMoIpCfgTableIndex } ::= { pwTDMoIpCfgTable 1 } PwTDMoIpCfgEntry ::= SEQUENCE { pwTDMoIpCfgTableIndex Unsigned32, pwTDMoIpCfgRowStatus RowStatus, pwTDMoIpCfgPayloadFormat INTEGER, pwTDMoIpCfgFarEndType INTEGER, pwTDMoIpCfgDelaySensitivity INTEGER, pwTDMoIpCfgFramesInPacket Unsigned32 } pwTDMoIpCfgTableIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index to an entry in this table" ::= { pwTDMoIpCfgEntry 1} pwTDMoIpCfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Object used for creating, modifying, and deleting a row of this table." ::= { pwTDMoIpCfgEntry 2 } pwTDMoIpCfgPayloadFormat OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), v1 (2), v2 (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "determine TDM over IP proprietary payload format." ::= { pwTDMoIpCfgEntry 3 } pwTDMoIpCfgFarEndType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), dsx1E1 (2), --E1 dsx1ESF (3), --T1 (ESF) dsx1SF (4), --T1 (SF) unframed (5) -- Serial } MAX-ACCESS read-create STATUS current DESCRIPTION "Determines TDM over IP Far End type." ::= { pwTDMoIpCfgEntry 4 } pwTDMoIpCfgDelaySensitivity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2),--Accurate Clock enable (3) --Constant Delay } MAX-ACCESS read-create STATUS current DESCRIPTION "Determines whether to optimize the clock for accurateness or for constant delay: o Disable (Accurate clock is more important than constant delay) o Enable (Constant delay is more important than accurate clock). This parameter is applicable only if PSN Type is TDMoIP , CESoIP, SATOP " ::= { pwTDMoIpCfgEntry 5 } pwTDMoIpCfgFramesInPacket OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "UDP payload length - determines the ethernet packet size " ::= { pwTDMoIpCfgEntry 6 } -- *** ATM Service radPwServiceCfgAtm OBJECT IDENTIFIER ::= { radPwServiceCfgObjects 2} pwAtmCfgXTable OBJECT-TYPE SYNTAX SEQUENCE OF PwAtmCfgXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of pwAtmCfgTable of PW-ATM-R-MIB. Each row that is added/removed there will be added/removed in this table." ::= { radPwServiceCfgAtm 1 } pwAtmCfgXEntry OBJECT-TYPE SYNTAX PwAtmCfgXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is indexed by pwIdx, the value of which is equal to the same index that was created for the associated entry in the PW Table (in the PW-STD-MIB)- the pwIndex. An entry may be created by Agent in this table for pseudo wires having ATM pwType" INDEX { pwIdx } ::= { pwAtmCfgXTable 1 } PwAtmCfgXEntry ::= SEQUENCE { pwAtmCfgAal5Mode INTEGER, pwAtmCfgAal5SduTermType INTEGER, pwAtmCfgTimeout Unsigned32 } pwAtmCfgAal5Mode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This objects defines whether AAL5 Mode is enabled for this PW." ::= { pwAtmCfgXEntry 1 } pwAtmCfgAal5SduTermType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), atm (2), router (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This objects defines the AAL5-SDU Termination Type. It means - where should the AAL5-SDU PW frame, received from PSN, be forwarded: atm(2) - forwarded into ATM VCC. router(3) - forwarded into router. ." ::= { pwAtmCfgXEntry 2 } pwAtmCfgTimeout OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Timeout period, measured in usec. Timeout mechanism is used in order to send out a packet before the maximum concatenated cells limit has been reached." ::= { pwAtmCfgXEntry 3 } -- ***Frame Relay Service PW Table radPwServiceCfgFr OBJECT IDENTIFIER ::= { radPwServiceCfgObjects 3} pwFrCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PwFrCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a set of parameters for Frame Relay PW in the pwFrTable." ::= { radPwServiceCfgFr 1 } pwFrCfgEntry OBJECT-TYPE SYNTAX PwFrCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "These parameters define the characteristics of a Frame Relay PW. This table is indexed by pwIdx, the value of which is equal to the same index that was created for the associated entry in the PW Table (in the PW-STD-MIB)- the pwIndex. An entry may be created by Agent in this table for pseudo wires having Frame Relay pwType" INDEX { pwIdx } ::= { pwFrCfgTable 1 } PwFrCfgEntry ::= SEQUENCE { pwFrCfgDlciFieldLength Unsigned32, pwFrCfgBitMarking BITS, pwFrCfgDlci Unsigned32 } pwFrCfgDlciFieldLength OBJECT-TYPE SYNTAX Unsigned32 (10|17|24) MAX-ACCESS read-write STATUS current DESCRIPTION "DLCI Field length in bytes. Possible values ae 10, 17 or 24" ::= { pwFrCfgEntry 1 } pwFrCfgBitMarking OBJECT-TYPE SYNTAX BITS { pwFrDeIncomingMarking (0), pwFrFecnIncomingMarking (1), pwFrBecnIncomingMarking (2), pwFrDeOutgoingMarking (3), pwFrFecnOutgoingMarking (4), pwFrBecnOutgoingMarking (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines which Frame Relay bits are copied into the outgoing interface or from the incoming interface. When labeled bit is 1, FR bit is copied. For incoming FR bits - DE, FECN and BECN: DE - pwFrDeIncomingMarking FECN - pwFrFecnIncomingMarking BECN - pwFrBecnIncomingMarking For outgoing FR bits - DE, FECN and BECN: DE - pwFrDeOutgoingMarking FECN - pwFrFecnOutgoingMarking BECN - pwFrBecnOutgoingMarking " ::= { pwFrCfgEntry 2 } pwFrCfgDlci OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "DLCI value of Frame Relay VC associated with this PW." ::= { pwFrCfgEntry 3 } -- PW Performance pwPerfCurrentXTable OBJECT-TYPE SYNTAX SEQUENCE OF PwPerfCurrentXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of pwPerfCurrentTable (PW-STD-R-MIB)." ::= { radPwPerfMonitoring 1 } pwPerfCurrentXEntry OBJECT-TYPE SYNTAX PwPerfCurrentXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in a table." INDEX { pwIdx } ::= { pwPerfCurrentXTable 1 } PwPerfCurrentXEntry ::= SEQUENCE { pwPerfCurrentInCongestDropPackets PerfCurrentCount, pwPerfCurrentOutCongestDropPackets PerfCurrentCount, pwPerfCurrentInLostPackets PerfCurrentCount } pwPerfCurrentInCongestDropPackets OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter for number of received packets that are dropped due to congestion by the PW (from the PSN) in the current 15-minute interval." ::= { pwPerfCurrentXEntry 1 } pwPerfCurrentOutCongestDropPackets OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter for number of transmitted packets that are dropped due to congestion by the PW (to the PSN) in the current 15-minute interval." ::= { pwPerfCurrentXEntry 2 } pwPerfCurrentInLostPackets OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter for number of incoming lost packets that are lost due to any reason in the current 15-minute interval. The counter takes into account both missing packets as defined by pwTDMPerfCurrentMissingPkts and packets detected out of order that could not be re-ordered or could not fit in the jitter buffer as defined by pwTDMPerfCurrentMisOrderDropped. See RFC5604. The object may be used by devices that not support standard counters mentioned above." ::= { pwPerfCurrentXEntry 3 } pwPerfIntervalXTable OBJECT-TYPE SYNTAX SEQUENCE OF PwPerfIntervalXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of pwPerfIntervalTable (PW-STD-R-MIB)." ::= { radPwPerfMonitoring 2 } pwPerfIntervalXEntry OBJECT-TYPE SYNTAX PwPerfIntervalXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in a table." INDEX { pwIdx, pwPerfIntervalXNumber } ::= { pwPerfIntervalXTable 1 } PwPerfIntervalXEntry ::= SEQUENCE { pwPerfIntervalXNumber Integer32, pwPerfIntervalInCongestDropPackets PerfIntervalCount, pwPerfIntervalOutCongestDropPackets PerfIntervalCount, pwPerfIntervalInLostPackets PerfIntervalCount } pwPerfIntervalXNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A number N, between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1. The minimum range of N is 1 through 4. The default range is 1 to 32. The maximum range of N is 1 through 96." ::= { pwPerfIntervalXEntry 1 } pwPerfIntervalInCongestDropPackets OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter for number of received packets that are dropped due to congestion by the PW (to the PSN) during the interval." ::= { pwPerfIntervalXEntry 2 } pwPerfIntervalOutCongestDropPackets OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter for number of transmitted packets that are dropped due to congestion by the PW (to the PSN) during the interval." ::= { pwPerfIntervalXEntry 3 } pwPerfIntervalInLostPackets OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter for number of incoming lost packets that are lost due to any reason in the 15-minute interval. The counter takes into account both missing packets as defined by pwTDMPerfIntervalMissingPkts and packets detected out of order that could not be re-ordered or could not fit in the jitter buffer as defined by pwTDMPerfIntervalMisOrderDropped. See RFC5604. The object may be used by devices that not support standard counters mentioned above." ::= { pwPerfIntervalXEntry 4 } -- ATM PW Performance pwAtmPerfCurrentXTable OBJECT-TYPE SYNTAX SEQUENCE OF PwAtmPerfCurrentXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of pwArmPerfCurrentTable (PW-ATM-R-MIB)." ::= { radPwPerfMonitoring 3 } pwAtmPerfCurrentXEntry OBJECT-TYPE SYNTAX PwAtmPerfCurrentXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in a table." INDEX { pwIdx } ::= { pwAtmPerfCurrentXTable 1 } PwAtmPerfCurrentXEntry ::= SEQUENCE { pwAtmPerfCurrentInDiscardTotalCells PerfCurrentCount, pwAtmPerfCurrentInDiscardClp0Cells PerfCurrentCount, pwAtmPerfCurrentTaggedCells PerfCurrentCount } pwAtmPerfCurrentInDiscardTotalCells OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of total received cells (CLP0 and CLP1) that were discarded by the traffic policer, in the current 15-minute interval." ::= { pwAtmPerfCurrentXEntry 1 } pwAtmPerfCurrentInDiscardClp0Cells OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received CLP0 cells that were discarded by the traffic policer, in the current 15-minute interval." ::= { pwAtmPerfCurrentXEntry 2 } pwAtmPerfCurrentTaggedCells OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of cells that were tagged by the traffic policer from CLP=0 to CLP=1, in the current 15-minute interval." ::= { pwAtmPerfCurrentXEntry 3 } pwAtmPerfIntervalXTable OBJECT-TYPE SYNTAX SEQUENCE OF PwAtmPerfIntervalXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of pwAtmPerfIntervalTable (PW-ATM-R-MIB)." ::= { radPwPerfMonitoring 4 } pwAtmPerfIntervalXEntry OBJECT-TYPE SYNTAX PwAtmPerfIntervalXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in a table." INDEX { pwIdx, pwAtmPerfIntervalXNumber } ::= { pwAtmPerfIntervalXTable 1 } PwAtmPerfIntervalXEntry ::= SEQUENCE { pwAtmPerfIntervalXNumber Integer32, pwAtmPerfIntervalInDiscardTotalCells PerfIntervalCount, pwAtmPerfIntervalInDiscardClp0Cells PerfIntervalCount, pwAtmPerfIntervalTaggedCells PerfIntervalCount } pwAtmPerfIntervalXNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A number N, between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1. The minimum range of N is 1 through 4. The default range is 1 to 32. The maximum range of N is 1 through 96." ::= { pwAtmPerfIntervalXEntry 1 } pwAtmPerfIntervalInDiscardTotalCells OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of total received cells (CLP0 and CLP1) that were discarded by the traffic policer, during the interval." ::= { pwAtmPerfIntervalXEntry 2 } pwAtmPerfIntervalInDiscardClp0Cells OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received CLP0 cells that were discarded by the traffic policer, during the interval." ::= { pwAtmPerfIntervalXEntry 3 } pwAtmPerfIntervalTaggedCells OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of cells that were tagged by the traffic policer from CLP=0 to CLP=1, during the interval." ::= { pwAtmPerfIntervalXEntry 4 } -- PW connectivity running statistics pwPerfConnTable OBJECT-TYPE SYNTAX SEQUENCE OF PwPerfConnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides connectivity statistics for PW troubleshooting." ::= { radPwPerfMonitoring 5 } pwPerfConnEntry OBJECT-TYPE SYNTAX PwPerfConnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in a table." INDEX { pwIdx } ::= { pwPerfConnTable 1 } PwPerfConnEntry ::= SEQUENCE { pwPerfConnJitterBufferLevel Gauge32, pwPerfConnMinJitterBufferLevel Gauge32, pwPerfConnMaxJitterBufferLevel Gauge32, pwPerfConnRoundTripDelay Gauge32, pwPerfConnMinRoundTripDelay Gauge32, pwPerfConnMaxRoundTripDelay Gauge32, pwPerfConnClearStats INTEGER } pwPerfConnJitterBufferLevel OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the current level (depth), in microseconds, of the jitter buffer." ::= { pwPerfConnEntry 1 } pwPerfConnMinJitterBufferLevel OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the minimum level (depth), in microseconds, of the jitter buffer since the last statistics reset." ::= { pwPerfConnEntry 2 } pwPerfConnMaxJitterBufferLevel OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the maximum level (depth), in microseconds, of the jitter buffer since the last statistics reset." ::= { pwPerfConnEntry 3 } pwPerfConnRoundTripDelay OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the current round trip delay (RTD), in microseconds." ::= { pwPerfConnEntry 4 } pwPerfConnMinRoundTripDelay OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the minimum round trip delay (RTD), in microseconds, since the last statistics reset." ::= { pwPerfConnEntry 5 } pwPerfConnMaxRoundTripDelay OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the maximum round trip delay (RTD), in microseconds, since the last statistics reset." ::= { pwPerfConnEntry 6 } pwPerfConnClearStats OBJECT-TYPE SYNTAX INTEGER { off (2), -- read-only value on (3) -- write-only value } MAX-ACCESS read-write STATUS current DESCRIPTION "A command that instructs the agent to clear the connectivity statistics i.e. to reset the values of the minimum and maximum jitter buffer levels and RTDs. Setting this object to on(3), shall clear the connectivity statistics. Upon completion, the value shall automatically change to off(2)." DEFVAL {off} ::= { pwPerfConnEntry 7 } -- PW connectivity current statistics pwPerfConnCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF PwPerfConnCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides per-PW connectivity statistics for the current 15-minute interval." ::= { radPwPerfMonitoring 6 } pwPerfConnCurrentEntry OBJECT-TYPE SYNTAX PwPerfConnCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table is created by the agent for every PW. After 15 minutes, the contents of this table entry are copied to a new entry in the pwPerfConnIntervalTable, and the counts in this entry are reset to zero." INDEX { pwIdx } ::= { pwPerfConnCurrentTable 1 } PwPerfConnCurrentEntry ::= SEQUENCE { pwPerfConnCurrentMinJitterBufferLevel Gauge32, pwPerfConnCurrentAvgJitterBufferLevel Gauge32, pwPerfConnCurrentMaxJitterBufferLevel Gauge32, pwPerfConnCurrentMinRoundTripDelay Gauge32, pwPerfConnCurrentAvgRoundTripDelay Gauge32, pwPerfConnCurrentMaxRoundTripDelay Gauge32 } pwPerfConnCurrentMinJitterBufferLevel OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the minimum level (depth), in microseconds, of the jitter buffer in the current 15-minute interval." ::= { pwPerfConnCurrentEntry 1 } pwPerfConnCurrentAvgJitterBufferLevel OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the average level (depth), in microseconds, of the jitter buffer in the current 15-minute interval." ::= { pwPerfConnCurrentEntry 2 } pwPerfConnCurrentMaxJitterBufferLevel OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the maximum level (depth), in microseconds, of the jitter buffer in the current 15-minute interval." ::= { pwPerfConnCurrentEntry 3 } pwPerfConnCurrentMinRoundTripDelay OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the minimum round trip delay (RTD), in microseconds, in the current 15-minute interval." ::= { pwPerfConnCurrentEntry 4 } pwPerfConnCurrentAvgRoundTripDelay OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the average round trip delay (RTD), in microseconds, in the current 15-minute interval." ::= { pwPerfConnCurrentEntry 5 } pwPerfConnCurrentMaxRoundTripDelay OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the maximum round trip delay (RTD), in microseconds, in the current 15-minute interval." ::= { pwPerfConnCurrentEntry 6 } -- PW connectivity interval statistics pwPerfConnIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF PwPerfConnIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides per-PW connectivity statistics for the history 15-minute intervals." ::= { radPwPerfMonitoring 7 } pwPerfConnIntervalEntry OBJECT-TYPE SYNTAX PwPerfConnIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table is created by the agent for every pwPerfConnCurrentEntry that is 15 minutes old. The contents of the current entry are copied to the new entry here. The current entry then resets its counts to zero for the next 15-minute interval." INDEX { pwIdx, pwPerfConnIntervalNumber } ::= { pwPerfConnIntervalTable 1 } PwPerfConnIntervalEntry ::= SEQUENCE { pwPerfConnIntervalNumber Unsigned32, pwPerfConnIntervalValidData TruthValue, pwPerfConnIntervalTimeElapsed Unsigned32, pwPerfConnIntervalStartTime DateAndTime, pwPerfConnIntervalMinJitterBufferLevel Gauge32, pwPerfConnIntervalAvgJitterBufferLevel Gauge32, pwPerfConnIntervalMaxJitterBufferLevel Gauge32, pwPerfConnIntervalMinRoundTripDelay Gauge32, pwPerfConnIntervalAvgRoundTripDelay Gauge32, pwPerfConnIntervalMaxRoundTripDelay Gauge32 } pwPerfConnIntervalNumber OBJECT-TYPE SYNTAX Unsigned32 (1..96) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A number N, between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15-minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1." ::= { pwPerfConnIntervalEntry 1 } pwPerfConnIntervalValidData OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates if the data for this interval is valid." ::= { pwPerfConnIntervalEntry 2 } pwPerfConnIntervalTimeElapsed OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The duration of this interval in seconds. Adjustments in the system's time-of-day clock may cause the interval to be greater or less than the normal value. Therefore, this actual interval value is provided." ::= { pwPerfConnIntervalEntry 3 } pwPerfConnIntervalStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time of start of this interval. Time zone octets are not used (OCTET STRING (SIZE (8))." ::= { pwPerfConnIntervalEntry 4 } pwPerfConnIntervalMinJitterBufferLevel OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the minimum level (depth), in microseconds, of the jitter buffer during the history 15-minute interval." ::= { pwPerfConnIntervalEntry 5 } pwPerfConnIntervalAvgJitterBufferLevel OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the average level (depth), in microseconds, of the jitter buffer during the history 15-minute interval." ::= { pwPerfConnIntervalEntry 6 } pwPerfConnIntervalMaxJitterBufferLevel OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the maximum level (depth), in microseconds, of the jitter buffer during the history 15-minute interval." ::= { pwPerfConnIntervalEntry 7 } pwPerfConnIntervalMinRoundTripDelay OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the minimum round trip delay (RTD), in microseconds, during the history 15-minute interval." ::= { pwPerfConnIntervalEntry 8 } pwPerfConnIntervalAvgRoundTripDelay OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the average round trip delay (RTD), in microseconds, during the history 15-minute interval." ::= { pwPerfConnIntervalEntry 9 } pwPerfConnIntervalMaxRoundTripDelay OBJECT-TYPE SYNTAX Gauge32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The gauge that shows the maximum round trip delay (RTD), in microseconds, during the history 15-minute interval." ::= { pwPerfConnIntervalEntry 10 } ---------------------------------------------------------- -- Pseudo Wire (PW) Common Trap Definitions ---------------------------------------------------------- -- CONFIGURATION MISMATCH pwConfigMismatch NOTIFICATION-TYPE OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason, pwDescr, pwGenMismatchReason } STATUS current DESCRIPTION "This trap indicates that a configuration mismatch was detected on the PW. Mismatches can be detected for example in: TDMoIP frame format, received frame length , TDMoIP version or when an Ethernet Frame is received instead of TDMoIP frame. " ::= { radPwNotifications 1 } -- OAM FAILURE pwOamFailure NOTIFICATION-TYPE OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason, pwDescr } STATUS current DESCRIPTION "This trap indicates that the OAM PW is disconnected. " ::= { radPwNotifications 2 } -- REMOTE DEFECT INDICATION (RDI) pwRdi NOTIFICATION-TYPE OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason, pwDescr } STATUS current DESCRIPTION "This trap indicates that a Remote Defect indication at the far end device was detected on the PW. " ::= { radPwNotifications 3 } -- RECEIVE FAILURE pwRxFailure NOTIFICATION-TYPE OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason, pwDescr } STATUS current DESCRIPTION "This trap indicates that Ethernet frames were not received on the PW. " ::= { radPwNotifications 4 } -- PW JITTER BUFFER OVERFLOW pwJitterBufferOverflow NOTIFICATION-TYPE OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason, pwDescr } STATUS current DESCRIPTION "This trap indicates that PW Jitter Buffer Overflow . " ::= { radPwNotifications 9 } -- PW JITTER BUFFER UNDERFLOW pwJitterBufferUnderflow NOTIFICATION-TYPE OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason, pwDescr } STATUS current DESCRIPTION "This trap indicates that PW Jitter Buffer Underflow . " ::= { radPwNotifications 10 } pwOamDelayTca NOTIFICATION-TYPE OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason, pwDescr, pwPerfConnRoundTripDelay, pwGenOamDelayThreshold } STATUS current DESCRIPTION "This trap indicates that OAM PW Delay threshold crossing alert. " ::= { radPwNotifications 11 } pwOamDelayTcaOff NOTIFICATION-TYPE OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason, pwDescr, pwPerfConnRoundTripDelay, pwGenOamDelayThresholdFalling } STATUS current DESCRIPTION "This trap indicates that OAM PW Delay is in the permitted range. " ::= { radPwNotifications 12 } END