RAD-ConfigChange-MIB DEFINITIONS ::= BEGIN -- It is RAD's intent to encourage the widespread use of -- this Specification in connection with the management of -- RAD products. RAD grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of RAD products. -- This Specification is supplied "as is," and RAD makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. IMPORTS sysName FROM SNMPv2-MIB Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI systemsEvents FROM RAD-GEN-MIB agnt FROM RAD-SMI-MIB; agnConfigChange MODULE-IDENTITY LAST-UPDATED "201502191800Z" -- February 19, 2015 ORGANIZATION "RAD Data Communications Ltd." CONTACT-INFO "System Department Email: mibs@rad.com Postal: RAD Data Communications Ltd. 24 Raoul Wallenberg St. Tel-Aviv 6971920 Israel Phone: +972-3-645-5421 Fax: +972-3-760-7844" DESCRIPTION "Configuration Change MIB." ::= { agnt 75 } -- NE (Network Element) Configuration Change (Sync between NMS and Device) -- -- The ConfigChange Notifications exist under the systemsEvents Node (RadGen.txt) configChange OBJECT IDENTIFIER ::= { agnConfigChange 1 } -- Additional nodes in the future can be added as { agnConfigChange 2, 3, 4 etc. } -- -- Configuration Change Table -- -- configurationChangeTable OBJECT-TYPE SYNTAX SEQUENCE OF ConfigurationChangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes all Configuration Tables OIDs that are supported by the device. When a configuration change is performed on a table, the configuration change ID shall be incremented and saved for this Table. Note that the configuration change ID is a global parameter and will be incremented whenever a change is made on any configuration table in the device. " ::= { configChange 1 } configurationChangeEntry OBJECT-TYPE SYNTAX ConfigurationChangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for configurationChangeTable. " INDEX { configurationChangeFamilyOid } ::= { configurationChangeTable 1 } ConfigurationChangeEntry ::= SEQUENCE { configurationChangeFamilyOid OBJECT IDENTIFIER, configurationChangeLastChangeId Unsigned32, configurationChangeOIDType INTEGER } configurationChangeFamilyOid OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Object Identifier of the current configuration table's family. This is the OID of the table that was configured without its row indices. For scalars, the object identifier shall be the OID of the family/tree that contains the changed scalar. " ::= { configurationChangeEntry 1 } configurationChangeLastChangeId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Configuration Change Id of the current configuration table. Each time a change is performed on the table (or scalars), the device shall increment its configurationChangeId and save it in this MIB object for the changed table. " ::= { configurationChangeEntry 2 } configurationChangeOIDType OBJECT-TYPE SYNTAX INTEGER { tableOID (2), scalarOID (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object indicates whether the familyOID that was sent is an OID of a table or of a scalar. " ::= { configurationChangeEntry 3 } configurationChangeId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of configuration change in the device. " ::= { configChange 2 } -- Reserved ::= { configChange 3 } configurationChangeTrapsEnable OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object indicates whether a configurationChange Trap will be sent. off (2) - configurationChangeTrap will not be sent. on (3) - configurationChangeTrap will be sent. " ::= { configChange 4 } configurationChangeEnd OBJECT-TYPE SYNTAX INTEGER { start (1), end (2), startAndEnd (3), continue (4) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This MIB object shall be attached as a varbind to the configurationChange Trap. It indicates whether the current configuration change trap has ended or whether it will be continued in the next trap. start (1) - the current configuration change trap is 1st in a sequence of configuration change traps. end (2) - the current configuration change is the last in sequence of configuration change traps. startAndEnd (3) - the current configuration change is a single trap. continue (4) - the current configuration change is within a trap sequence, not 1st and not last. " ::= { configChange 5 } configChangeNotificationTable OBJECT-TYPE SYNTAX SEQUENCE OF ConfigChangeNotificationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used for marking the added, changed and removed instances. In addition, it points to removed/added rows. This table is used for notifications only. " ::= { configChange 6 } configChangeNotificationEntry OBJECT-TYPE SYNTAX ConfigChangeNotificationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the configChangeNotificationTable. Each entry contains the OID that is used for the changed/removed/added MIB object/row. " INDEX { configChangeNotificationFamilyOid } ::= { configChangeNotificationTable 1 } ConfigChangeNotificationEntry ::= SEQUENCE { configChangeNotificationFamilyOid OBJECT IDENTIFIER, configChangeNotificationAdd OBJECT IDENTIFIER, configChangeNotificationChange OBJECT IDENTIFIER, configChangeNotificationRemove OBJECT IDENTIFIER } configChangeNotificationFamilyOid OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Family OID of the entry (row) that was removed or added to a configuration table. The Family OID consists of the configured table OID without the row indices segment. For a changed MIB object, the index will have a value of 0.0 ." ::= { configChangeNotificationEntry 1 } configChangeNotificationAdd OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This MIB object shall be attached to the configurationChange notification when a row is added to a table. The value of this MIB object will be 0.0 . The index (configChangeNotificationFamilyOid) will be 0.0 too. This MIB object marks the beginning of the Add section in the notification. It shows that a cluster of additions is now beginning. After this variable, all the added variables with their values will follow. " ::= { configChangeNotificationEntry 2 } configChangeNotificationChange OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This MIB object shall be attached to the configurationChange notification when a MIB object has been changed. The value of this MIB object will be 0.0 . The index (configChangeNotificationFamilyOid) will be 0.0 too. This MIB object marks the beginning of the Change section in the notification. It shows that a cluster of changes is now beginning. After this variable, all the changed variables with their new values will follow. " ::= { configChangeNotificationEntry 3 } configChangeNotificationRemove OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This MIB object shall be attached to the configurationChange notification when a row is removed from a table. Its value is the indices of the removed row. configChangeNotificationFamilyOid with the configChangeNotificationRemove OIDs point to the removed row. " ::= { configChangeNotificationEntry 4 } configChangeTransactionKey OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object defines the unique information specifically associated with a configuration SET PDU. The agent will return the transaction key as a varbind in the systemConfigurationChange trap." ::= { configChange 7 } -------------------------------------------- -- Configuration Change Common Trap Definitions -------------------------------------------- systemConfigurationChange NOTIFICATION-TYPE OBJECTS { configurationChangeId, configChangeTransactionKey } -- Additional attached variables: configChangeNotificationAdd, -- List of Added rows fields with their values, -- configChangeNotificationChange, -- List of MIB objects that were changed with their new values, -- For each removed row: configChangeNotificationRemove, -- configurationChangeEnd, -> for last trap only -- trapSeqId STATUS current DESCRIPTION "This Trap shall be sent upon any configuration change in the device. " ::= { systemsEvents 79} systemConfigChangeEnableTraps NOTIFICATION-TYPE OBJECTS { sysName, configurationChangeId, configurationChangeTrapsEnable } STATUS current DESCRIPTION "This Trap shall be sent when the user enables/disables the configurationChange Trap. configurationChange traps will not be sent." ::= { systemsEvents 80} -- Reserved ::= { systemsEvents 81} END