-- -- file :a2002nv3.pkb -- ACE2002-MIB DEFINITIONS ::= BEGIN --Title: ACE2002 MIB -- Copyright 2201 RAD Data Communications, Ltd. -- All Rights Reserved. -- It is RAD's intent to encourage the widespread use of -- this Specification in connection with the management of -- RAD products. RAD grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of RAD products. -- This Specification is supplied "as is," and RAD makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. IMPORTS TimeTicks,enterprises, IpAddress, OBJECT-TYPE, Integer32, Counter32, Gauge32, OBJECT-IDENTITY, NOTIFICATION-TYPE, Counter64,Unsigned32 FROM SNMPv2-SMI PerfCurrentCount, PerfIntervalCount, PerfTotalCount FROM PerfHist-TC-MIB InterfaceIndex, ifAlias, ifIndex FROM IF-MIB dsx1LineStatus, dsx1LineStatusLastChange, dsx1CurrentIndex, dsx1LineIndex, dsx1IntervalIndex, dsx1IntervalNumber, dsx1LoopbackStatus, dsx1TotalIndex FROM DS1-MIB imaGroupIndex, imaLinkIfIndex, imaGroupFailureStatus FROM IMA-MIB RowStatus, DisplayString, TimeStamp, DateAndTime, TruthValue FROM SNMPv2-TC SnmpAdminString FROM SNMP-FRAMEWORK-MIB frAtmIwfConnectionEntry FROM FR-ATM-PVC-SERVICE-IWF-MIB isdnSignalingEntry FROM ISDN-MIB VlanIndex, PortList FROM Q-BRIDGE-MIB dot1dBasePortEntry FROM BRIDGE-MIB atmfCESConfEntry FROM ATMF-CES atmVclEntry, aal5VccEntry, aal5VccVpi, aal5VccVci, atmVplVpi, atmVclVpi, atmVclVci, atmVpCrossConnectEntry, atmVcCrossConnectEntry, atmVclEntry, aal5VccEntry FROM ATM-MIB IANAifType FROM IANAifType-MIB ipoaLisIfMappingEntry FROM IPOA-MIB ; -- Some MIB compilers need those two lines: -- enterprises OBJECT IDENTIFIER ::= -- { iso org(3) dod(6) internet(1) private(4) 1 } MacAddress ::= OCTET STRING (SIZE(6)) rad OBJECT IDENTIFIER ::= { enterprises 164 } radTokenRing OBJECT IDENTIFIER ::= { rad 1 } -- RAD Token Ring tree radFddi OBJECT IDENTIFIER ::= { rad 2 } -- rad FDDI Tree radWan OBJECT IDENTIFIER ::= { rad 3 } -- rad WAN Tree radBridges OBJECT IDENTIFIER ::= {rad 4 } radConverters OBJECT IDENTIFIER ::= { rad 5 } -- RAD Converters products' tree radGen OBJECT IDENTIFIER ::= { rad 6} -- General information radStkHub OBJECT IDENTIFIER ::= { rad 7 } -- stackable products radAtm OBJECT IDENTIFIER ::= { rad 12} -- stackable products wanGen OBJECT IDENTIFIER ::= {radWan 1} diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} --atmNte OBJECT IDENTIFIER ::= { radAtm 3 } --atmNtePrt OBJECT IDENTIFIER ::= { atmNte 2 } --atmNtePrtConfig OBJECT IDENTIFIER ::= { atmNtePrt 1 } --dacsMux OBJECT IDENTIFIER ::= {radWan 3} --genDacsMux OBJECT IDENTIFIER ::= {dacsMux 4} radRouter OBJECT IDENTIFIER ::= { rad 11 } rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 } radExperimental OBJECT IDENTIFIER ::= { rad 20 } -- Drafts that have no MIB tree yet -- igmpStdMIB MODULE-IDENTITY ::= { radExperimental 1 } -- apsMIB OBJECT IDENTIFIER ::= { radExperimental 2 } -- -- file :v:\doc\rdv\mib\ver495\radgen.txt -- --Version: 5.00 --First Version Date: 25.01.99 --By: Orly Nicklass --File: radgen.txt --Last update: 09-Oct-2003 by Smadar Tauber systems OBJECT IDENTIFIER ::= { radGen 1} -- list of RAD products --agnt OBJECT IDENTIFIER ::= { radGen 2} agent general tree --services OBJECT IDENTIFIER ::= { radGen 3} See services.txt radSysTR OBJECT IDENTIFIER ::= { systems 1 } -- RAD Token Ring radRADring OBJECT IDENTIFIER ::= { radSysTR 1 } radTMA OBJECT IDENTIFIER ::= { radSysTR 2 } radRingMonitor OBJECT IDENTIFIER ::= { radSysTR 3 } radSysFddi OBJECT IDENTIFIER ::= { systems 2 } -- RAD Fddi radFDX100 OBJECT IDENTIFIER ::= { radSysFddi 1 } -- RAD Fddi radSysWan OBJECT IDENTIFIER ::= { systems 3 } -- RAD Wan products radSysWanEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD Wan products." ::= { radSysWan 0 } radMP2100 OBJECT IDENTIFIER ::= { radSysWan 1 } radMP2104 OBJECT IDENTIFIER ::= { radSysWan 2 } radMP2100B OBJECT IDENTIFIER ::= { radSysWan 3 } radMP2100F OBJECT IDENTIFIER ::= { radSysWan 4 } radMP2100H OBJECT IDENTIFIER ::= { radSysWan 5 } radMP2104H OBJECT IDENTIFIER ::= { radSysWan 6 } radMP2200B OBJECT IDENTIFIER ::= { radSysWan 7 } radMP2200F OBJECT IDENTIFIER ::= { radSysWan 8 } radMX3000 OBJECT IDENTIFIER ::= { radSysWan 9 } radMX3004 OBJECT IDENTIFIER ::= { radSysWan 10 } radMX30 OBJECT IDENTIFIER ::= { radSysWan 11 } radMX300 OBJECT IDENTIFIER ::= { radSysWan 12 } radVOIP OBJECT IDENTIFIER ::= { radSysWan 13 } radKM2100 OBJECT IDENTIFIER ::= { radSysWan 15 } radKM2104 OBJECT IDENTIFIER ::= { radSysWan 16 } radDXC30 OBJECT IDENTIFIER ::= { radSysWan 20 } radDXC10A OBJECT IDENTIFIER ::= { radSysWan 21 } radDXC8R OBJECT IDENTIFIER ::= { radSysWan 22 } radDXC30E OBJECT IDENTIFIER ::= { radSysWan 23 } radDXC3000 OBJECT IDENTIFIER ::= { radSysWan 24 } radDXC8RNew OBJECT IDENTIFIER ::= { radSysWan 25 } radFcdT1L OBJECT IDENTIFIER ::= { radSysWan 28 } radFcdE1L OBJECT IDENTIFIER ::= { radSysWan 29 } radFcdT1 OBJECT IDENTIFIER ::= { radSysWan 30 } radFcdE1 OBJECT IDENTIFIER ::= { radSysWan 31 } radFcdE1I OBJECT IDENTIFIER ::= { radSysWan 32 } radFcdT1M OBJECT IDENTIFIER ::= { radSysWan 33 } radFcdE1M OBJECT IDENTIFIER ::= { radSysWan 34 } radFcdIP OBJECT IDENTIFIER ::= { radSysWan 35} radFcdT1A OBJECT IDENTIFIER ::= { radSysWan 36 } radFcdE1A OBJECT IDENTIFIER ::= { radSysWan 37 } radFcdW OBJECT IDENTIFIER ::= { radSysWan 38 } radFcdSTM OBJECT IDENTIFIER ::= { radSysWan 39 } radHtuE1Sa OBJECT IDENTIFIER ::= { radSysWan 40 } radHtuE1 OBJECT IDENTIFIER ::= { radSysWan 41 } --card radHtu2Sa OBJECT IDENTIFIER ::= { radSysWan 42 } radHtu2 OBJECT IDENTIFIER ::= { radSysWan 43 } --card radAsmi450R768Sa OBJECT IDENTIFIER ::= { radSysWan 44 } radAsmi450R768 OBJECT IDENTIFIER ::= { radSysWan 45 } --card radAsmi450R1152Sa OBJECT IDENTIFIER ::= { radSysWan 46 } radAsmi450R1152 OBJECT IDENTIFIER ::= { radSysWan 47 } --card radLrs12F OBJECT IDENTIFIER ::= { radSysWan 48 } radLrs12B OBJECT IDENTIFIER ::= { radSysWan 49 } radLrs52 OBJECT IDENTIFIER ::= { radSysWan 50 } radHcdE1Sa OBJECT IDENTIFIER ::= { radSysWan 51 } radHcdE1 OBJECT IDENTIFIER ::= { radSysWan 52 } --card radHtuT1Sa OBJECT IDENTIFIER ::= { radSysWan 53 } radHtuT1 OBJECT IDENTIFIER ::= { radSysWan 54 } --card radOptimux4E1 OBJECT IDENTIFIER ::= { radSysWan 55 } radOptimux4T1 OBJECT IDENTIFIER ::= { radSysWan 56 } radOptimuxXLE1 OBJECT IDENTIFIER ::= { radSysWan 57 } radOptimuxXLT1 OBJECT IDENTIFIER ::= { radSysWan 58 } radOptimuxXL16E1 OBJECT IDENTIFIER ::= { radSysWan 59 } radImx64 OBJECT IDENTIFIER ::= { radSysWan 60 } radImx6L OBJECT IDENTIFIER ::= { radSysWan 61 } radImx2 OBJECT IDENTIFIER ::= { radSysWan 62 } radImx4T1 OBJECT IDENTIFIER ::= { radSysWan 63 } radImx4E1 OBJECT IDENTIFIER ::= { radSysWan 64 } radImx2T1E1 OBJECT IDENTIFIER ::= { radSysWan 65 } radImxi4 OBJECT IDENTIFIER ::= { radSysWan 66 } radOptimux155 OBJECT IDENTIFIER ::= { radSysWan 67 } --SA radOptimux4T1L OBJECT IDENTIFIER ::= { radSysWan 68 } --SA Low Cost radOptimux4E1L OBJECT IDENTIFIER ::= { radSysWan 69 } --SA Low Cost radHtuE1SaV2 OBJECT IDENTIFIER ::= { radSysWan 70 } radHtuE1V2 OBJECT IDENTIFIER ::= { radSysWan 71 } --card radFomiE3 OBJECT IDENTIFIER ::= { radSysWan 72 } --card radFomiT3 OBJECT IDENTIFIER ::= { radSysWan 73 } --card radOpt4E1C OBJECT IDENTIFIER ::= { radSysWan 74 } --card radOpt4T1C OBJECT IDENTIFIER ::= { radSysWan 75 } --card radPrbiE3 OBJECT IDENTIFIER ::= { radSysWan 76 } --SA radPrbiT3 OBJECT IDENTIFIER ::= { radSysWan 77 } --SA radHcd4Sa OBJECT IDENTIFIER ::= { radSysWan 78 } --SA radOptimuxT3 OBJECT IDENTIFIER ::= { radSysWan 79 } --SA radFRmon OBJECT IDENTIFIER ::= { radSysWan 80 } radIpMux4 OBJECT IDENTIFIER ::= { radSysWan 81 } radIpMux1 OBJECT IDENTIFIER ::= { radSysWan 82 } radIpMux16 OBJECT IDENTIFIER ::= { radSysWan 83 } radIpMux1E OBJECT IDENTIFIER ::= { radSysWan 84 } radVmux2100 OBJECT IDENTIFIER ::= { radSysWan 85 } radMP104 OBJECT IDENTIFIER ::= { radSysWan 86 } radMP204 OBJECT IDENTIFIER ::= { radSysWan 87 } radVmux110 OBJECT IDENTIFIER ::= { radSysWan 88 } -- reserved for radVmux105 OBJECT IDENTIFIER ::= { radSysWan 89 } radFcd155 OBJECT IDENTIFIER ::= { radSysWan 90 } --SA radIpMux8 OBJECT IDENTIFIER ::= { radSysWan 91 } radOptimux155DS3 OBJECT IDENTIFIER ::= { radSysWan 92 } --SA radOptimuxT3L OBJECT IDENTIFIER ::= { radSysWan 93 } --SA Low Cost -- reserved for radIpMux1000 OBJECT IDENTIFIER ::= { radSysWan 94 } radOp16E1L OBJECT IDENTIFIER ::= { radSysWan 95 } --19 inch box radOp16E1LS OBJECT IDENTIFIER ::= { radSysWan 96 } --half 19 inch box (single) radPRBm20 OBJECT IDENTIFIER ::= { radSysWan 97 } -- half 19 inch box radPRBm22 OBJECT IDENTIFIER ::= { radSysWan 98 } -- 19 inch box -- reserved for radAsmi52Sa OBJECT IDENTIFIER ::= { radSysWan 99 } radOpXLE1 OBJECT IDENTIFIER ::= { radSysWan 100 } -- New-Look radOpXLT1 OBJECT IDENTIFIER ::= { radSysWan 101 } -- New-Look radOpXL16E1 OBJECT IDENTIFIER ::= { radSysWan 102 } -- New-Look radSysBRG OBJECT IDENTIFIER ::= { systems 4 } -- RAD Bridges products radTRE1 OBJECT IDENTIFIER ::= { radSysBRG 1 } -- RAD Bridges products radTRE1D OBJECT IDENTIFIER ::= { radSysBRG 2 } -- RAD Bridges products radTRE8 OBJECT IDENTIFIER ::= { radSysBRG 3 } -- RAD Bridges products radTRE8D OBJECT IDENTIFIER ::= { radSysBRG 4 } -- RAD Bridges products radMBE1 OBJECT IDENTIFIER ::= { radSysBRG 5 } -- RAD Bridges products radMBE1D OBJECT IDENTIFIER ::= { radSysBRG 6 } -- RAD Bridges products radMBE8 OBJECT IDENTIFIER ::= { radSysBRG 7 } -- RAD Bridges products radMBE8D OBJECT IDENTIFIER ::= { radSysBRG 8 } -- RAD Bridges products radMLBT OBJECT IDENTIFIER ::= { radSysBRG 9 } -- RAD Bridges products radFEB4DAS OBJECT IDENTIFIER ::= { radSysBRG 10 } -- RAD Bridges products radTrimBrg10 OBJECT IDENTIFIER ::= { radSysBRG 11 } -- RAD Bridges products radTrimBrg16 OBJECT IDENTIFIER ::= { radSysBRG 12 } -- RAD Bridges products radRRTRE8 OBJECT IDENTIFIER ::= { radSysBRG 13 } -- RAD Bridges products radRRTRE8D OBJECT IDENTIFIER ::= { radSysBRG 14 } -- RAD Bridges products radRRMLBT OBJECT IDENTIFIER ::= { radSysBRG 15 } -- RAD Bridges products radRRMLBTF OBJECT IDENTIFIER ::= { radSysBRG 16 } -- RAD Bridges products radRRTRE1D OBJECT IDENTIFIER ::= { radSysBRG 17 } -- RAD Bridges products radTRERAS OBJECT IDENTIFIER ::= { radSysBRG 18 } -- RAD Bridges products radTRERASa OBJECT IDENTIFIER ::= { radSysBRG 19 } -- RAD Bridges products radMBERAS OBJECT IDENTIFIER ::= { radSysBRG 20 } -- RAD Bridges products radMBERASa OBJECT IDENTIFIER ::= { radSysBRG 21 } -- RAD Bridges products radFEB4FDX OBJECT IDENTIFIER ::= { radSysBRG 22 } -- RAD Bridges products radFEB4SAS OBJECT IDENTIFIER ::= { radSysBRG 23 } -- RAD Bridges products radRRFTBDAS OBJECT IDENTIFIER ::= { radSysBRG 24 } -- RAD Bridges products radRRFTBSAS OBJECT IDENTIFIER ::= { radSysBRG 25 } -- RAD Bridges products radFTBDAS OBJECT IDENTIFIER ::= { radSysBRG 26 } -- RAD Bridges products radFTBSAS OBJECT IDENTIFIER ::= { radSysBRG 27 } -- RAD Bridges products radFastWay100 OBJECT IDENTIFIER ::= { radSysBRG 28 } -- RAD Bridges products radSysCnvrtr OBJECT IDENTIFIER ::= { systems 5 } -- RAD Converters products radSTC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 1 } -- RAD Converters products radSTC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 3 } -- RAD Converters products radSTC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 4 } -- RAD Converters products radSTC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 6 } -- RAD Converters products radFTC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 10 } -- RAD Converters products radFTC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 12 } -- RAD Converters products radFTC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 13 } -- RAD Converters products radFTC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 15 } -- RAD Converters products radSEC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 20 } -- RAD Converters products radSEC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 22 } -- RAD Converters products radSEC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 23 } -- RAD Converters products radSEC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 25 } -- RAD Converters products radFEC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 30 } -- RAD Converters products radFEC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 32 } -- RAD Converters products radFEC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 33 } -- RAD Converters products radFEC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 35 } -- RAD Converters products radRIC155 OBJECT IDENTIFIER ::= { radSysCnvrtr 36 } -- RAD Converters products radSysStkHub OBJECT IDENTIFIER ::= { systems 7 } -- RAD Stackable products radRBHE OBJECT IDENTIFIER ::= { radSysStkHub 1 } -- RAD Stackable products radRBHT OBJECT IDENTIFIER ::= { radSysStkHub 2 } -- RAD Stackable products radRBHEEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD Stackable products." ::= { radRBHE 0 } radRBHTEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD Stackable products." ::= { radRBHT 0 } radETS4fddiDAS OBJECT IDENTIFIER ::= { radSysStkHub 3 } -- RAD Stackable products radETS4fddiSAS OBJECT IDENTIFIER ::= { radSysStkHub 4 } -- RAD Stackable products radSAHEMX OBJECT IDENTIFIER ::= { radSysStkHub 5 } -- RAD Stackable products radSAHTM OBJECT IDENTIFIER ::= { radSysStkHub 6 } -- RAD Stackable products radETS4 OBJECT IDENTIFIER ::= { radSysStkHub 7 } -- RAD Stackable products radSAHEMU OBJECT IDENTIFIER ::= { radSysStkHub 8 } -- RAD Stackable products unknown OBJECT IDENTIFIER ::= { radSysStkHub 9 } -- RAD Stackable products radSAH16Eint OBJECT IDENTIFIER ::= { radSysStkHub 10 } -- RAD Stackable products radSAH16Tint OBJECT IDENTIFIER ::= { radSysStkHub 11 } -- RAD Stackable products radSAH16Eext OBJECT IDENTIFIER ::= { radSysStkHub 12 } -- RAD Stackable products radSAH16Text OBJECT IDENTIFIER ::= { radSysStkHub 13 } -- RAD Stackable products radSysPS OBJECT IDENTIFIER ::= { systems 8 } -- RAD Packet Switch (PS) products radSysPSEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD Packet Switch (PS) products." ::= { radSysPS 0 } radSPS2 OBJECT IDENTIFIER ::= { radSysPS 1 } -- RAD Packet Switch (PS) products radSPS3 OBJECT IDENTIFIER ::= { radSysPS 2 } -- RAD Packet Switch (PS) products radSPS6 OBJECT IDENTIFIER ::= { radSysPS 3 } -- RAD Packet Switch (PS) products radSPS9 OBJECT IDENTIFIER ::= { radSysPS 4 } -- RAD Packet Switch (PS) products radSPS12 OBJECT IDENTIFIER ::= { radSysPS 5 } -- RAD Packet Switch (PS) products radAPD2 OBJECT IDENTIFIER ::= { radSysPS 6 } -- RAD Packet Switch (PS) products radAPD8 OBJECT IDENTIFIER ::= { radSysPS 7 } -- RAD Packet Switch (PS) products radAPS8 OBJECT IDENTIFIER ::= { radSysPS 8 } -- RAD Packet Switch (PS) products radAPS16 OBJECT IDENTIFIER ::= { radSysPS 9 } -- RAD Packet Switch (PS) products radAPS24 OBJECT IDENTIFIER ::= { radSysPS 10 } -- RAD Packet Switch (PS) products radSPS3S OBJECT IDENTIFIER ::= { radSysPS 11} -- RAD Packet Switch (PS) products radFPS8 OBJECT IDENTIFIER ::= { radSysPS 12} -- RAD Packet Switch (PS) products radFPS12 OBJECT IDENTIFIER ::= { radSysPS 13} -- RAD Packet Switch (PS) products radSPS3ScSL OBJECT IDENTIFIER ::= { radSysPS 14} -- RAD Packet Switch (PS) products radSPS3Sc2S OBJECT IDENTIFIER ::= { radSysPS 15} -- RAD Packet Switch (PS) products radFPS8c OBJECT IDENTIFIER ::= { radSysPS 16} -- RAD Packet Switch (PS) products radFPS4 OBJECT IDENTIFIER ::= { radSysPS 17} -- RAD Packet Switch (PS) products radSysEth OBJECT IDENTIFIER ::= { systems 9 } -- RAD Ethernet products radEP8T OBJECT IDENTIFIER ::= {radSysEth 1} -- RAD Ethernet products radEP4TAUI OBJECT IDENTIFIER ::= {radSysEth 2} -- RAD Ethernet products radEP4T2FL OBJECT IDENTIFIER ::= {radSysEth 3} -- RAD Ethernet products radEP4TFL OBJECT IDENTIFIER ::= {radSysEth 4} -- RAD Ethernet products radEP4FL OBJECT IDENTIFIER ::= {radSysEth 5} -- RAD Ethernet products radEPR8T OBJECT IDENTIFIER ::= {radSysEth 7} -- RAD Ethernet products radEPR4TAUI OBJECT IDENTIFIER ::= {radSysEth 8} -- RAD Ethernet products radEPR4T2FL OBJECT IDENTIFIER ::= {radSysEth 9} -- RAD Ethernet products radEPR4TFL OBJECT IDENTIFIER ::= {radSysEth 10} -- RAD Ethernet products radEPR4FL OBJECT IDENTIFIER ::= {radSysEth 11} -- RAD Ethernet products radSysRtr OBJECT IDENTIFIER ::= { systems 11 } -- RAD Router products radSysRtrEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD Router products." ::= { radSysRtr 0 } radRTED OBJECT IDENTIFIER ::= {radSysRtr 1} -- RAD Router products radRTEM OBJECT IDENTIFIER ::= {radSysRtr 2} -- RAD Router products radRTEC OBJECT IDENTIFIER ::= {radSysRtr 3} -- RAD Router products radWebRanger OBJECT IDENTIFIER ::= {radSysRtr 4} -- RAD Router products radTinyRouter OBJECT IDENTIFIER ::= {radSysRtr 5} -- RAD Router products radLA240 OBJECT IDENTIFIER ::= {radSysRtr 6} -- RAD Router products radSuperLan OBJECT IDENTIFIER ::= {radSysRtr 7} -- RAD Router products (LA-240) radLA240I OBJECT IDENTIFIER ::= {radSysRtr 8} -- RAD Router products radFcdIsdn OBJECT IDENTIFIER ::= {radSysRtr 9} -- RAD Router products radEFcdIp OBJECT IDENTIFIER ::= {radSysRtr 10} -- RAD Router products (FCD-IP/D) radFcdIpD OBJECT IDENTIFIER ::= {radSysRtr 11} -- RAD Router products radFcdIpM OBJECT IDENTIFIER ::= {radSysRtr 12} -- RAD Router products (LA-240) radSysAtm OBJECT IDENTIFIER ::= { systems 12 } -- RAD ATM products radSysAtmEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD ATM products." ::= { radSysAtm 0 } radStarSwitch OBJECT IDENTIFIER ::= {radSysAtm 1} --RAD StartSwitch products radStarSwitchATM25 OBJECT IDENTIFIER ::= {radStarSwitch 1} --RAD StartSwitch products radStarSwitchATM25L OBJECT IDENTIFIER ::= {radStarSwitch 2} --RAD StartSwitch products radStarSwitchATM155 OBJECT IDENTIFIER ::= {radStarSwitch 3} --RAD StartSwitch products radAtmCsuDsu OBJECT IDENTIFIER ::= {radSysAtm 2} --RAD CSU/DSU products radAmcdE1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 1} -- RAD CSU/DSU products radAmcdT1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 2} -- RAD CSU/DSU products radAce20E OBJECT IDENTIFIER ::= {radAtmCsuDsu 3} -- RAD CSU/DSU products radAce20T OBJECT IDENTIFIER ::= {radAtmCsuDsu 4} -- RAD CSU/DSU products radAce2005 OBJECT IDENTIFIER ::= { radAtmCsuDsu 5} -- RAD ACE2005 radAce2002 OBJECT IDENTIFIER ::= { radAtmCsuDsu 6} -- RAD ACE2002 radAce2002E OBJECT IDENTIFIER ::= { radAtmCsuDsu 7} -- RAD ACE2002E radAce2E OBJECT IDENTIFIER ::= {radAtmCsuDsu 8} -- RAD CSU/DSU products radAce2T OBJECT IDENTIFIER ::= {radAtmCsuDsu 9} -- RAD CSU/DSU products radMlAtmE1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 10} -- RAD ATM Piggy radMlAtmT1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 11} -- RAD ATM Piggy radAmc102 OBJECT IDENTIFIER ::= {radAtmCsuDsu 12} -- RAD AMC102 radAmc102c OBJECT IDENTIFIER ::= {radAtmCsuDsu 13} -- RAD AMC102 CARD radAce202 OBJECT IDENTIFIER ::= { radAtmCsuDsu 14} -- RAD ACE202 radAce OBJECT IDENTIFIER ::= {radSysAtm 3} --RAD ACE products radAce101 OBJECT IDENTIFIER ::= {radAce 1} -- RAD ACE101 radAce102 OBJECT IDENTIFIER ::= {radAce 2} -- RAD ACE102 radAce50 OBJECT IDENTIFIER ::= {radAce 3} -- RAD ACE50 radAce52 OBJECT IDENTIFIER ::= {radAce 4} -- RAD ACE52 radSysLA OBJECT IDENTIFIER ::= {systems 13} --RAD IAD (Integrated Access Device) products radLA140 OBJECT IDENTIFIER ::= {radSysLA 1} -- RAD LA-140 radLA110 OBJECT IDENTIFIER ::= {radSysLA 2} -- RAD LA-110 radLA104 OBJECT IDENTIFIER ::= {radSysLA 3} -- RAD LA-104 (LA-110 with IMA) radSysTerminal OBJECT IDENTIFIER ::= {systems 100} --RAD Terminal Meta-MIB; -- no objects should be added to this branch in RAD MIB. agnt OBJECT IDENTIFIER ::= { radGen 2} -- agent general tree -- Agent General agnHwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ASCII string for description and display of the agent hardware version, as it is known by the agent software.The user can update the version upon request when he changes components in the agent's module " ::= { agnt 1 } agnTrapMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this attribute determines the type of traps the agent should mask and not send to the management console. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed." ::= { agnt 2 } agnTrapValue OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The value of the trap decoded in internal RAD format. Full description is given in the Trap definition file" ::= {agnt 3} agnChangeCnt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of changes in system configuration that were reported to the manager since last cold start" ::= {agnt 4 } agnSpecific OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION " Object identifier of entity containing additional information regarding this instance." ::= { agnt 5} agnConfigMsg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Full configuration message coded in internal RAD application format. This entry describes agent's configuration. For MP-2200 R3, this object describes agent's support of the V5.1 feature: 1 octet ; bit 0 (LSB). '1' - V5.1 feature is supported '0' - V5.1 feature is not supported." ::= { agnt 6 } -- Manager table to record all IP addresses mngTrapIpTable OBJECT-TYPE SYNTAX SEQUENCE OF MngEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table indicates the destination address of the traps. Internally it will be limited to ten addresses. " ::= { agnt 7 } mngEntry OBJECT-TYPE SYNTAX MngEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mngID } ::= { mngTrapIpTable 1 } MngEntry ::= SEQUENCE { mngID Integer32, mngIP IpAddress, mngIPMask IpAddress, mngTrapMask Integer32 } mngID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This value indicates an index of a specific IP address" ::= { mngEntry 1 } mngIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This value indicates the destination address of the traps. IP 0.0.0.0 removes the entry. " ::= { mngEntry 2 } mngIPMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This value indicates the mask of the destination addresses of the traps. " ::= { mngEntry 3 } mngTrapMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this attribute determines the type of traps the agent should mask and not send to this NMS. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed." ::= { mngEntry 4 } agnIndication OBJECT-TYPE SYNTAX INTEGER { faulty (1), -- =major warning (2), normal (3), -- off minor (4), major (5), event (6), critical(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Attribute describing the state of the entity the agent is responsible for. In case of a modular entity, the value of this attribute will be according to the component which is in the worst state. The order of severity (from top to bottom) is: critical-> major (or faulty)-> minor-> event-> warning-> normal (off)." ::= { agnt 8 } agnMonitorModeCmd OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, will enforce the agent to change its mode of operation to Monitor Mode" ::= {agnt 9} agnLed OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the LEDs status of the agent module . Each led will be represented by 4 bits where the first 2 bits (left) will specify the status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) will specify the color : (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY)" ::= {agnt 10} trapTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes the last few traps generated by the agent, for future retrieval. The table has a limited capacity. If traps are not retrieved in proper time, they will be over-written by new traps " ::= {agnt 11} trapEntry OBJECT-TYPE SYNTAX TrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { trapID } ::= { trapTable 1 } TrapEntry ::= SEQUENCE { trapID Integer32, trapVal DisplayString, trapTimeSinceOccurrence TimeTicks } trapID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This value indicates an index of a specific trap " ::= { trapEntry 1 } trapVal OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the actual ASCII description of the trap. " ::= { trapEntry 2 } trapTimeSinceOccurrence OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates the amount of time passed since the occurrence of the event that trigger this trap. " ::= { trapEntry 3 } fileTransfer OBJECT IDENTIFIER ::= { agnt 12 } fileServerIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the server from which the file is loaded " ::= { fileTransfer 1 } fileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the file to be loaded. For protection, read returns NULL. " ::= { fileTransfer 2 } fileTransCmd OBJECT-TYPE SYNTAX INTEGER { swDwnLoad (1), configDwnLoad (2), configUpLoad (3), coProcDwnLoad (4), stateUpLoad (5), dwnLoadUserFile (6), upLoadUserFile (7), swDwnLoadAndReset (8), swUpLoad (9), noOp (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The command to be executed on fileName at fileServerIP." ::= { fileTransfer 3 } -- tftp group tftpRetryTimeOut OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " General Retransmission time-out value (seconds) " -- DEFVAL { 15 } ::= { fileTransfer 4 } tftpTotalTimeOut OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Total Retransmission time-out value (seconds) " -- DEFVAL { 60 } ::= { fileTransfer 5 } tftpStatus OBJECT-TYPE SYNTAX INTEGER { noOp(2), connecting(3), transferringData(4), endedTimeOut(5), endedOk(6), error(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Status of tftp session. When a session ended with success, the tftpStatus should be endedOk(6). Before restarting a tftp session, the NMS should set the tftpStatus to noOp(2). That's the reason of MAX-ACCESS read-write to this field." DEFVAL { noOp} ::= { fileTransfer 6 } tftpError OBJECT-TYPE SYNTAX OCTET STRING ( SIZE(2) ) MAX-ACCESS read-only STATUS current DESCRIPTION " The MSB represents the standard error code. The LSB represents the private error code. 0x0000 is No Error 0x0100 is File Not Found 0x0400 is Illegal TFTP operation 0x0500 is Unknown transfer ID 0x0001 is Server Overflow 0x0002 is No empty UDP port 0x0003 is No empty connection 0x0004 is Illegal File Mode 0x0007 is Illegal PDU size " DEFVAL { '0000'h } ::= { fileTransfer 7 } fileTransferToSubSystems OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION " This object represents the sub-systems the fileTransCmd refers to. It should be used when a system is divided to sub-systems and each sub-system (or part of them) can have a different SW/Configuration. Each bit of this object will represent one of the sub-systems. Bit='1' - APPLY to respective sub-system Bit='0' - DO NOT APPLY to respective sub-system For the meaning of each bit, see product's specification. User will select the sub-systems envolved by filling-in the bits that represent these sub-systems. In this case, the file represented by 'fileName' will include several parts, each representing one of the sub-systems. The agent will refer only to the part/s indicated by this object. 0 Octet Strings = not applicable DEFVAL = 0h for the products that support this object." ::= { fileTransfer 8 } fileNameWithinProduct OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The file name used by the product within the product file system." ::= { fileTransfer 9 } --Internal SW Download table intSwdlTable OBJECT-TYPE SYNTAX SEQUENCE OF IntSwdlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameters table is for internal Software down load. It also includes data about all files contained in the Object from which down-load is performed." ::= { fileTransfer 10 } intSwdlEntry OBJECT-TYPE SYNTAX IntSwdlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {intSwdlObjIdx, intSwdlFileIdx } ::= { intSwdlTable 1} IntSwdlEntry ::= SEQUENCE { intSwdlObjIdx Integer32, intSwdlFileIdx Integer32, intSwdlFileName DisplayString, intSwdlFileSwVer DisplayString, intSwdlSwDate DisplayString, intSwdlSize DisplayString, intSwdlCmd INTEGER, intSwdlToSubSystem OCTET STRING } intSwdlObjIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the object from which down-load is performed." ::= {intSwdlEntry 1} intSwdlFileIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the files included in intSwdlObjIdx. One of these files can be selected to be internally downloaded." ::= {intSwdlEntry 2} intSwdlFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the file." ::= {intSwdlEntry 3} intSwdlFileSwVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The software version of the file." ::= {intSwdlEntry 4} intSwdlSwDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The software version date of the file." ::= {intSwdlEntry 5} intSwdlSize OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The size of the file." ::= {intSwdlEntry 6} intSwdlCmd OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The command to down-load a SW file to an object. The Agent will change the value of this MIB object to off(2) automatically, after accepting the command." ::= {intSwdlEntry 7} intSwdlToSubSystem OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION " This object defines the subsystem for download. Bit='1'- APPLY to respective sub system. Bit='0'- DO NOT APPLY to respective sub system. For more details see product specification. For every octet bit0=LSB, bit7=MSB" ::= { intSwdlEntry 8 } --SW Download Status table swdlStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SwdlStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameters table is for software download status. It also includes data about the files down-loaded or attempted to be down-loaded." ::= { fileTransfer 11 } swdlStatusEntry OBJECT-TYPE SYNTAX SwdlStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {swdlStatusTypeIdx, swdlStatusIdx } ::= { swdlStatusTable 1} SwdlStatusEntry ::= SEQUENCE { swdlStatusTypeIdx Integer32, swdlStatusIdx Integer32, swdlStatusFileName DisplayString, swdlStatusSlot DisplayString, swdlStatusSubSystem DisplayString, swdlStatusStatus Integer32, swdlStatusTime DisplayString } swdlStatusTypeIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the down-load type (e.g. external (1) or internal (2))." ::= {swdlStatusEntry 1} swdlStatusIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the status rows." ::= {swdlStatusEntry 2} swdlStatusFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the file." ::= {swdlStatusEntry 3} swdlStatusSlot OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The slot of the updated (or attempted to be updated) object." ::= {swdlStatusEntry 4} swdlStatusSubSystem OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The subsystem that updated (or attempted to be updated)." ::= {swdlStatusEntry 5} swdlStatusStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the down load process. Value: Fail (2), OK (3), InProcess (4)." ::= {swdlStatusEntry 6} swdlStatusTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB parameter indicates the time SW download was finished. The format shuld be YYYY-MM-DD, hh:mm:ss" ::= {swdlStatusEntry 7} clearDwldStatusLog OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object clears the status log. Value: off(2), external(3), internal(4) The Agent will change the value of this MIB object to off(2) automatically, after accepting the command ." ::= { fileTransfer 12 } systemReset OBJECT-TYPE SYNTAX INTEGER { off (2), on (3), --HW resetConfig (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset action to be performed on the system." ::= { agnt 13 } systemTiming OBJECT IDENTIFIER ::= { agnt 14 } systemDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System date." ::= { systemTiming 1 } systemTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System time." ::= { systemTiming 2 } systemPort OBJECT IDENTIFIER ::= { agnt 15 } physicalConnectorTable OBJECT-TYPE SYNTAX SEQUENCE OF PhysicalConnectorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes the connector type of ports or interfaces." ::= {systemPort 1} physicalConnectorEntry OBJECT-TYPE SYNTAX PhysicalConnectorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {portIdx} ::= { physicalConnectorTable 1 } PhysicalConnectorEntry ::= SEQUENCE { portIdx Integer32, physicalConnector INTEGER, portOptWaveLength INTEGER, portOptMode INTEGER, portBalance INTEGER } portIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used." ::= { physicalConnectorEntry 1 } physicalConnector OBJECT-TYPE SYNTAX INTEGER { other (1), v35 (2), --34 pin female rs530 (3), --DB25 x21 (4), --DB15 bnc (5), utp (6), --RJ45 aui (7), rs422 (8), --DB25 crossUtp (9), --RJ45 rj45 (10), v24 (11), --DB25 g703 (12), --TB5 termBlock3AndRj45 (13), terminalBlock3 (14), terminalBlock5 (15), terminalBlock7 (16), db25 (17), db15 (18), rj45ethernet (19), termBlock5AndRj45 (20), db9 (21), g703E1 (22), --BNC-RJ45-BNC g703E1-LTU (23), --BNC-RJ45-BNC sc (24), --sc optical st (25), --st optical stl (26), fc (27), --fc optical tb5w (28), --Term-Block-5-Wire (for HCD) termBlock6AndRj45 (29), ethBnc (30), scsi26 (31), --SCSI with 26 pins eth4381 (32), --RJ45 with two embeded LEDs twoBnc (33), --Two BNC scsi50 (34), --SCSI with 50 pins twoMiniBnc (35), --Two mini BNC sf1 (36), --sf1=single fiber optical terminalBlock4 (37), sf2 (38), --sf2=single fiber optical db25Balanced (39), --DB25 Balanced v36 (40), block4W (41), --like in WR connector for Modems iripRj45 (42), irEthQRj45 (43), iripBnc (44), rs530WA (45), --rs530/IR that solves a wander problem for SDH network v35WA (46), --v35/IR that solves a wander problem for SDH network irEthQBnc (47), v35Db25 (48), --V.35 with connector DB25 rj11 (49), --Used for FXS & FXO mtrj (50), --optical lc (51), --optical terminalBlock2 (52), irEth10s100 (53), --IR-ETH 10/100 scsi68 (54), -- SCSI 68 pins sf3 (55), -- sf3=single fiber of sc optical fcLH (56), -- fc Long Haul telco50 (57), -- TELCO 50 telco64 (58), -- TELCO 64 irEthQN (59), none (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The connector of the port/interface. other - none of the specified connectors none - no connector." ::= { physicalConnectorEntry 2 } portOptWaveLength OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), nm850(2), nm1300(3), nm1300Laser(4), nm1550Laser(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Wave Length of an Optical interface/port in [nm] and specification if Laser or not. notApplicable - for non-optical ports." ::= { physicalConnectorEntry 3 } portOptMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), singleMode(2), multiMode(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Laser Mode of an Optical Laser interface/port. notApplicable - for non-Laser ports." ::= { physicalConnectorEntry 4 } portBalance OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), unbalanced (2), balanced (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is according to the port Impedance. For T1 - always balanced. For E1 - there are different impedance values for balanced and unbalanced." ::= { physicalConnectorEntry 5 } prtSupervisory OBJECT IDENTIFIER ::= { systemPort 2 } prtSpTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {prtSupervisory 1} prtSpEntry OBJECT-TYPE SYNTAX PrtSpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Supervisory port parameter table." INDEX {prtSupervisoryIndex } ::= { prtSpTable 1} PrtSpEntry ::= SEQUENCE { prtSupervisoryIndex Integer32, prtSupervisoryRate INTEGER, prtSupervisoryDataBits INTEGER, prtSupervisoryParity INTEGER, prtSupervisoryStopBits INTEGER, prtSupervisoryUsage INTEGER, prtSupervisoryInterface INTEGER, prtSupervisoryCTS INTEGER, prtSupervisoryDcdDelay INTEGER, prtSupervisoryDSR INTEGER, prtSupervisoryRoutProtocol INTEGER } prtSupervisoryIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The SP port index. For some products, having modules (cards): The LS byte of the integer is the port index 1..255. The MS byte is different than 0 only if the port belongs to a module. In that case it is the module number. For other products' index see their specification." ::= { prtSpEntry 1} prtSupervisoryRate OBJECT-TYPE SYNTAX INTEGER { auto (1), s300bps (2), s1200bps (3), s2400bps (4), s4800bps (5), s9600bps (6), s19200bps (7), s38400bps (8), s57600bps (9), s115200bps (10) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the operation rate (speed) of the port. auto - automatic rate selection, by the agent." ::= { prtSpEntry 2} prtSupervisoryDataBits OBJECT-TYPE SYNTAX INTEGER { dataBits7 (1), dataBits8 (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the number of data bits in an async frame" ::= { prtSpEntry 3} prtSupervisoryParity OBJECT-TYPE SYNTAX INTEGER { none (1), odd (2), even (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the parity mode in an async frame" ::= { prtSpEntry 4} prtSupervisoryStopBits OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), stopBits1 (2), stopBits1dot5 (3), stopBits2 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the parity mode in an async frame." ::= { prtSpEntry 5} prtSupervisoryUsage OBJECT-TYPE SYNTAX INTEGER { unknown (1), noUse (2), terminal(3), nmsSlip (4), nmsPpp (5), muxSlip (6), muxPpp (7), dialOut (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the usage of the SP port." ::= { prtSpEntry 6} prtSupervisoryInterface OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), dce (2), dte (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the supervisory port interface." ::= { prtSpEntry 7} prtSupervisoryCTS OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), on (2), --Old value for DCE. rts (3), --Old value for DCE dteWait (4), --DTE will wait for CTS to become active before transmit date. dteIgnore (5) --DTE will Ignore CTS signal and will transmit date anyway. } MAX-ACCESS read-write STATUS current DESCRIPTION "CTS line state." ::= { prtSpEntry 8} prtSupervisoryDcdDelay OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), d0 (2), d10 (3), d50 (4), d100 (5), d200 (6), d300 (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "DCD delay in msec." ::= { prtSpEntry 9} prtSupervisoryDSR OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), on (2), dtr (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "DSR line state." ::= { prtSpEntry 10} prtSupervisoryRoutProtocol OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), proprietary (3), rip2 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the routing protocol of the port. notApplicable - for DP." ::= { prtSpEntry 11} --Port Performance Data prtPerformance OBJECT IDENTIFIER ::= { systemPort 3 } prtPerfTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtPerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes G.826 ports or interfaces." ::= {prtPerformance 1} prtPerfEntry OBJECT-TYPE SYNTAX PrtPerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtPerfIdx, prtPerfPeriodRef} ::= { prtPerfTable 1 } PrtPerfEntry ::= SEQUENCE { prtPerfIdx Integer32, prtPerfPeriodRef INTEGER, prtPerfElapsedTime Integer32, prtPerfUAS Integer32, prtPerfES Integer32, prtPerfSES Integer32, prtPerfBBE Integer32, prtPerfBlocksPerSec Integer32, prtPerfTimeTag TimeTicks, prtPerfSaveAndResetCmd INTEGER } prtPerfIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used." ::= { prtPerfEntry 1 } prtPerfPeriodRef OBJECT-TYPE SYNTAX INTEGER { currentPeriod (1), lastPeriod (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last prtPerfSaveAndResetCmd received or since Start-up (if no prtPerfSaveAndResetCmd was received since Start-up) until now. lastPeriod - the period between last two commands of prtPerfSaveAndResetCmd. - If only one command occured since Start-up: the period between Start-up and last command. - If no command occured since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0." ::= { prtPerfEntry 2 } prtPerfElapsedTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Elapsed Time in seconds. - for prtPerfPeriodRef=currentPeriod: The period since last prtPerfSaveAndResetCmd received or since Start-up (if no prtPerfSaveAndResetCmd was received since Start-up) until now. - for prtPerfPeriodRef=lastPeriod: The value of prtPerfElapsedTime when last prtPerfSaveAndResetCmd was received." ::= { prtPerfEntry 3 } prtPerfUAS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Unavailable Seconds for the reference period (prtPerfPeriodRef)." ::= { prtPerfEntry 4 } prtPerfES OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Errored Seconds for the reference period (prtPerfPeriodRef)." ::= { prtPerfEntry 5 } prtPerfSES OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Severely Errored Seconds for the reference period (prtPerfPeriodRef)." ::= { prtPerfEntry 6 } prtPerfBBE OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Background Block (or Frame) Errors for the reference period (prtPerfPeriodRef)." ::= { prtPerfEntry 7 } prtPerfBlocksPerSec OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Blocks per second (or frames per second) of the port/interface indicated by portIdx. This object is constant for a certain port/interface. It is not affected by the prtPerfPeriodRef index." ::= { prtPerfEntry 8 } prtPerfTimeTag OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Time Tag of Last Period: sysUpTime when last prtPerfSaveAndResetCmd was executed. This object is applicable only for prtPerfPeriodRef=lastPeriod. For prtPerfPeriodRef=currentPeriod, the value will always be 0." ::= { prtPerfEntry 9 } prtPerfSaveAndResetCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "A command per port/interface, to Save data of Current Period in Last Period data-set and start a new counting period for Current Period. This object is applicable only for prtPerfPeriodRef=currentPeriod. Setting this object to on(3) for prtPerfPeriodRef=last, will cause the agent to return: Bad Value response. When setting validly this object to on(3), agent will perform the required command and will reset automatically the value of this object to off(2). Setting this object to off(2), will do nothing." ::= { prtPerfEntry 10 } --Port Test Data prtTest OBJECT IDENTIFIER ::= { systemPort 4 } prtTestTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes test data for ports or interfaces." ::= {prtTest 1} prtTestEntry OBJECT-TYPE SYNTAX PrtTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtTestIdx} ::= { prtTestTable 1 } PrtTestEntry ::= SEQUENCE { prtTestIdx Integer32, prtTestCmdAndStatus Integer32, prtBertCounter Integer32, prtTestInitiator INTEGER, prtTestTimeout Integer32 } prtTestIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used." ::= { prtTestEntry 1 } prtTestCmdAndStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to a value as detailed further on (except 0) will initiate a test on the specific port. The test/s requested will be set according to the respective bit. The value of this object will be a sum of (2**n), where n is the Bit: TEST BIT VALUE ----------- --- ------ reserved 0 1 PayloadLoop=RLB 1 (=Remote Loopback) 2 LineLoop=DIG 2 (=Digital) 4 OtherLoop 3 8 InwardLoop=LLB 4 (=Local Loopback) 16 BERT 5 32 LC 6 64 ToneInjection 7 128 Inband 8 256 e.g : If the requested value is 20 -> 010100 -> Bits 2 & 4 are set -> the requested tests are : LineLoopback=DIG InwardLoopback=LLB Not all tests combinations are valid. For valid test combination, see each product's specification. For LRS52, only single test is allowed simultaneously The terminology and order of the first tests (except BERT) is according to the one used for Test Status of DS1 and DS3 standards. The notations : RLB, LLB, DIG are the most used in RAD's products, but they can be different. For exact definition see product's spec. Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port. When no test is running on the port, the Get value (test status) will be 0. PayloadLoop=RLB The received signal at this interface is looped through the device. Typically the received signal is looped back for retransmission after it has passed through the device's framing function. LineLoop=DIG The received signal at this interface does not go through the device (minimum penetration) but is looped back out. OtherLoop Loopbacks that are not defined here. InwardLoop=LLB The sent signal at this interface is looped back through the device. LC This loop is applicable only for HSSI interface, towards the router . ToneInjection This loop is applicable for analog voice (like FXS)." ::= { prtTestEntry 2 } prtBertCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of BERT errors encountered during the BERT operation. It is valid only when BERT (Bit Error Rate Test) is active on the specific port. The Counter starts from zero (0) anytime BERT is initiated." ::= { prtTestEntry 3} prtTestInitiator OBJECT-TYPE SYNTAX INTEGER { unknown (1), user (2), remoteUnit(3), dteRouter (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates who initiated this port's test/s." ::= { prtTestEntry 4 } prtTestTimeout OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only when a single test is running. It indicates the test activation timeout in minutes. When the timeout expires, the test is stopped. Value of 0 indicates test may run Forever " ::= { prtTestEntry 5 } --Port General Parameters prtParam OBJECT IDENTIFIER ::= { systemPort 5 } prtParamTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes general port parameters. The meaning is different for every product that supports it due to a general parameter - prtControlCnfg. For ACE2002: -This table is used as a mechanism to create the next interface index. The algorithm description: The NMS will send the agent the following get command: get(nextIfIndex.index), where index=interface on which the new index is dependent on. Upon this command the agent will generate and return the new index to the NMS. - This table is partially supported according to the interface type. Upon getNext function the irrelevant parameters will be skipped." ::= {prtParam 1} prtParamEntry OBJECT-TYPE SYNTAX PrtParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtParamIdx} ::= { prtParamTable 1 } PrtParamEntry ::= SEQUENCE { prtParamIdx Integer32, prtControlCnfg Integer32, prtParamClkSrc INTEGER, prtParamPhantom INTEGER, prtParamResetStatsCmd INTEGER, prtParamLastResetStatsTime TimeStamp, prtParamInterfaceType INTEGER, prtParamClearAlarm INTEGER, prtParamLeds OCTET STRING } prtParamIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used. For ACE2002: This parameter is the physical layer ifIndex of the slot on which the NMS requires the next interface index." ::= { prtParamEntry 1 } prtControlCnfg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object may be used for port RW general parameter/s. For detailed meaning, see product's spec. Supported by: PRBi-E3/T3. For ACE2002: This parameter will include the value of the new index generated by agent. For Optimux-T3 and OP-155-1: This parameter will be used for Release Remote LLB Command: on=2= Set value only. Command to release LLB of Remote Unit. Agent will return automatically to 'off' value after performing the command. off=3=Get value only. For LA140 This parameter will be used as EchoCanceler per timeslot off = 2 Echo Canceler is disabled on = 3 Echo Canceler is enabled For FCD-155 This parameter will be used to select the port that is clock source for a PDH port, when 2495.dsx1TransmitClockSource=throughTiming. VC12/VT1.5 = 2 SDH/SONET = 3 For ACE-52 This parameter will be used as Transmit Frame Type, i.e. which type of frame the corresponding bridge port will transmit: Untagged = 2 Tagged = 3 ." ::= { prtParamEntry 2 } prtParamClkSrc OBJECT-TYPE SYNTAX INTEGER { loopTiming (1), localTiming (2), throughTiming (3), adaptive (4), master (5), fallback (6), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The source of Transmit Clock. 'loopTiming' or 'loopback' indicates that the recovered receive clock is used as the transmit clock. 'localTiming' or 'internal' indicates that a local clock source is used or when an external clock is attached to the box containing the interface. 'throughTiming' or 'external' indicates that recovered receive clock from another card or interface is used as the transmit clock. 'adaptive' indicates that the clock is recovered according to the received data flow rate. 'master' and 'fallback' values may be used RO to indicate active clock." ::= { prtParamEntry 3 } prtParamPhantom OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Power feeding to another device." ::= { prtParamEntry 4 } prtParamResetStatsCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset statistics of the selected port." ::= { prtParamEntry 5 } prtParamLastResetStatsTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of MIB II's sysUpTime object at the last time that prtParamResetStatsCmd was Set to on(3) for this port. If prtParamResetStatsCmd was never Set to on(3) since last re-initialization of the agent, then this object contains a zero value. This object enables calculating the running time of Statistics counters for this port, by: [sysUpTime-prtParamLastResetStatsTime]. For some devices other types of 'Reset' may affect this parameter" ::= { prtParamEntry 6 } prtParamInterfaceType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), e1 (2), t1 (3), fr (4), hdlc (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of the port." ::= { prtParamEntry 7 } prtParamClearAlarm OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, will enforce a clear operation on the Port Alarms. Upon completion, the value will automatically change to off(2)." ::= { prtParamEntry 8 } prtParamLeds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the LEDs status of the port. Each led is represented by 4 bits where the first 2 bits (left) specify the status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) specify the color : (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY). The order of the LEDS is from top to bottom, left to right: For each row starting from the top, the LEDS are returned from left to right." ::= {prtParamEntry 9} prtIP OBJECT IDENTIFIER ::= { systemPort 6 } prtIpParamTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtIpParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table - Parameters for IP Ports." ::= {prtIP 1} prtIpParamEntry OBJECT-TYPE SYNTAX PrtIpParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtIpParamConfigIdx, prtIpParamSlotIdx, prtIpParamIdx } ::= { prtIpParamTable 1 } PrtIpParamEntry ::= SEQUENCE { prtIpParamConfigIdx Integer32, prtIpParamSlotIdx Integer32, prtIpParamIdx Integer32, prtIpParamHostIP IpAddress, prtIpParamHostMask IpAddress, prtIpParamDefaultGateway IpAddress, prtIpParamMediaMode INTEGER, prtIpParamMediaRate INTEGER, prtIpParamMngVlanSupport INTEGER, prtIpParamMngVlanId Integer32, prtIpParamMngVlanPriority Integer32, prtIpParamRingMode INTEGER, prtIpParamProtIpEnable INTEGER, prtIpParamTrafficPriority INTEGER, prtIpParamRemoteIP IpAddress, prtIpParamMaxTxBandwidth INTEGER } prtIpParamConfigIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). For products having Agent and Edit configurations, Write operation for the table entries is allowed only to Config=255." ::= { prtIpParamEntry 1 } prtIpParamSlotIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique number of the slot position in which the module is inserted. notApplicable = 255 (for products that don't have slots). For KM: kmxMlA (103), kmxMlB (104)." ::= { prtIpParamEntry 2 } prtIpParamIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique Port Index." ::= { prtIpParamEntry 3 } prtIpParamHostIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The host interface IP address." ::= { prtIpParamEntry 4 } prtIpParamHostMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The host interface subnet mask." ::= { prtIpParamEntry 5 } prtIpParamDefaultGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Default Gateway's IP Address." ::= { prtIpParamEntry 6 } prtIpParamMediaMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), halfDuplex (2), fullDuplex (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the real Media Mode." ::= { prtIpParamEntry 7 } prtIpParamMediaRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r10Mbps (2), r100Mbps (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the real Media Rate (Mbps)." ::= { prtIpParamEntry 8 } prtIpParamMngVlanSupport OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Management VLAN support (Tagging). no - No support of VLAN Tagging. yes - 4 VLAN bytes will be added to the frame." ::= { prtIpParamEntry 9 } prtIpParamMngVlanId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Management VLAN ID." ::= { prtIpParamEntry 10 } prtIpParamMngVlanPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Management VLAN Frame priority." ::= { prtIpParamEntry 11 } prtIpParamRingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates If Ring Mode is enabled or not." ::= { prtIpParamEntry 12 } prtIpParamProtIpEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether a list of Protected IP Addresses is enabled or not. This object is applicable only if prtIpParamRingMode=enable." ::= { prtIpParamEntry 13 } prtIpParamTrafficPriority OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), low (2), high (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the traffic priority of this port." ::= { prtIpParamEntry 14 } prtIpParamRemoteIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This is the IP Address of the remote device that is connected to the current device (Point to Point Application). It is used for sending OAM packets on the LAN to the remote side in order to check that the connection is OK." ::= { prtIpParamEntry 15 } prtIpParamMaxTxBandwidth OBJECT-TYPE SYNTAX INTEGER { full (2), e1 (3), t1 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object shows the Max Bandwidth allowed on the LAN. Full - means that a Maximum of 100 Mega Byte Rate may go through the LAN. e1(3) means that the maximum is an E1 rate. t1(4) is for a maximum of a T1 rate." ::= { prtIpParamEntry 16 } prtClkSrc OBJECT IDENTIFIER ::= { systemPort 7 } prtClkSrcTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtClkSrcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table - Parameters for master and fallback clock source of ports ." ::= {prtClkSrc 1} prtClkSrcEntry OBJECT-TYPE SYNTAX PrtClkSrcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtClkSrcCnfgIdx, prtClkSrcPrtIdx, prtClkSrcIdx} ::= { prtClkSrcTable 1} PrtClkSrcEntry ::= SEQUENCE { prtClkSrcCnfgIdx Integer32, prtClkSrcPrtIdx Integer32, prtClkSrcIdx INTEGER, prtClkSrcMode INTEGER, prtClkSrcPrt Integer32 } prtClkSrcCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg." ::= { prtClkSrcEntry 1} prtClkSrcPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates a unique Port Index (receiving clock). Refer to device specification for port Index" ::= { prtClkSrcEntry 2} prtClkSrcIdx OBJECT-TYPE SYNTAX INTEGER { master (1), fallback (2) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "An index in the table. master - refers Master clock parameters fallback - refers Fallback clock parameters" ::= { prtClkSrcEntry 3} prtClkSrcMode OBJECT-TYPE SYNTAX INTEGER { -- none (1), internal (2), rxClk (3), -- station (4), -- lbt (5), -- ntr (6), -- adaptive (7), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the source the nodal timing is locked to. " ::= { prtClkSrcEntry 4} prtClkSrcPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This entry is valid only when working in rxClk mode. It specifies the port from which the clock willl be taken. Refer to device specification for source port Index" ::= { prtClkSrcEntry 5} systemResetAllStatsCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset statistics of all ports and connections of the device." ::= { agnt 16 } systemClearTablesCmd OBJECT-TYPE SYNTAX INTEGER { off(2), tempCnfgTables (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "tempCnfgTables - Set *RowStatus = destroy for all entries of some tables having *RowStatus object, for temporary configuration only! (255). For the relevant tables, see product's specification. This object should be used by WAN product applications before performing the Update operation, in order to clear old entries of these tables. For MP-104/204 the entries will be destroyed for cnfg=1. off - agent will automatically change to this value, after performing the command. " ::= { agnt 17 } systemParameter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter can be used for different purposes: - TELNET session time-out in seconds. - Ace20: when trying to create row in a table that already has row with the same values, if set of values has to be unique in table, this attribute is set to the index of the existing row. - Optimux-T3: when CH interfaces are RJ-45, user can select via this object, the interface type for each Group of channels: T1 or E1: The selection will be a sum of the following Bits. '0' = T1 '1' = E1 Bit Group Value for each Bit having '1' 1 1 (CH-1..CH-8) 1 2 2 (CH-9..CH-12) 2 3 3 (CH-13..CH-20) 4 4 4 (CH-21..CH-28) 8 Examples: 15 = all Groups are selected to be E1 6 = Group 2 and Group 3 are selected to be E1 (Group 1 and Group 4 are T1). - FCD-A, FCD-M: user can select via this object the configuration used for Get values of MSDSL parameters that don't have configuration index. 1 =active configuration 255=temporary configuration. Set of this object should be done before Getting the MSDSL RW parameters. - Ace2002: This parameter indicates the number of intervals that were successfully uploaded upon statistics collection session. - FCD-IP, WR, FCD-IPD, LA-240: This parameter indicates whether Telnet Access is enabled/disabled: Values: 2 - Telnet Access is Disabled. 3 - Telnet Access is Enabled. -Vmux-110: This parameter value equals to maximum number of bundles. -Optimux-155: Simmilar usage to Optimux T3. user can select via this object, interface type T1 or E1 for each Group of channels (LIU): LIU group consists of 7 channels. Up to 12 LIUs are represented (84 T1 Channels). The selection will be a sum of the 2**n For each bit:'0' = T1 ,'1' = E1 Bit Group 1 1 (CH-1 .. CH-7) 2 2 (CH-8 .. CH-14) 3 3 (CH-15 ..CH-21) ... 9 9 (CH-56.. CH-63) ... 10 10 (CH-64..CH-70) 11 11 (CH-71..CH-77) 12 12 (CH-78..CH-84) " ::= { agnt 18 } agnGlobalAlarmMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this attribute determines the alarm traps the agent should mask and not send to the managers. Each bit from a certain octet represents a certain alarm." ::= { agnt 19 } alarmSeverity OBJECT-TYPE SYNTAX INTEGER { event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the severity of the alarms." ::= { agnt 20 } alarmState OBJECT-TYPE SYNTAX INTEGER { off (2), -- End, on (3) -- Start. } MAX-ACCESS read-only STATUS current DESCRIPTION "." ::= { agnt 21 } agnTestStatus OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current test status (for all levels: system, card, port). This attribute will be set to: on(3): when there is at least one test in progress on the system/card/port off(2): when there is NO test in progress on the system/card/port" ::= {agnt 22 } systemSaveAndResetAllStatsCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "on - a command to Save data of Current Period in Last Period data-set and start a new counting period for Current Period. off - agent will automatically change to this value, after performing the command." ::= { agnt 23 } systemDefaultGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Default Gateway's IP Address." ::= { agnt 24 } -- PS Table systemPsTable OBJECT-TYPE SYNTAX SEQUENCE OF SystemPsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the PS types of a device. Usage of this table is specified in the device's NMS SRS" ::= { agnt 25 } systemPsEntry OBJECT-TYPE SYNTAX SystemPsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {systemPsIndex1, systemPsIndex2} ::= { systemPsTable 1 } SystemPsEntry ::= SEQUENCE { systemPsIndex1 Integer32, systemPsIndex2 Integer32, systemPsType INTEGER, systemPsStatus INTEGER, systemPsHotSwap INTEGER } systemPsIndex1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "First Index. In HUBs: 1 = PS-A slot 2 = PS-B slot. In SA units: 1 = PS1 2 = PS2 Default = 1" ::= { systemPsEntry 1 } systemPsIndex2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Second Index. In HUBs: 1 always. In SA units: 1 = Local 2 = Remote Default = 1." ::= { systemPsEntry 2 } systemPsType OBJECT-TYPE SYNTAX INTEGER { none (1), ac (2), dc (3), acDc (4), acPF (5), dcPF (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of PS, for a stand-alone product. acDc - AC with rj45 DC. acPF - Power Feeding (phantom) box that is feeding another box by external AC. dcPF - Power Feeding (phantom) box that is feeding another box by external DC." ::= { systemPsEntry 3 } systemPsStatus OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), failed (2), ok (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Status of the PS unit." ::= { systemPsEntry 4 } systemPsHotSwap OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), fixed (2), hotSwap (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is PS unit hot swap or fixed." ::= { systemPsEntry 5 } agnFans OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the FANs existence and status. Each fan will be represented by 2 bits, where the first bit (right) will specify the existence: (0= Not exist, 1=exist), and the left bit will specify it's status (0= OK, 1=FAIL), so for each fan: 00 - FAN does not exist 01 - FAN exists and OK 11 - FAN exists and is Failed bits 0-1 are for first fan bits 2-3 are for 2nd fan (if exists)." ::= { agnt 26 } agnSendTrapParameter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies if the agent will attach a specific parameter to a trap. For ACE2002 the agent will attach or not the openViewSeverity parameter according to the value of this parameter: 1 - will attach openViewSeverity. 0 - will not attach openViewSeverity." ::= { agnt 27 } agnSensorsStatus OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the Sensors (Temperature sensors or others) existence and status. Each sensor will be represented by 2 bits, where the first bit (right) will specify the existence: (0= Not exist, 1=exist), and the left bit will specify it's status (0= OK, 1=FAIL), so for each sensor: 00 - sensor does not exist 01 - sensor exists and status is OK 11 - sensor exists and status is not OK ( e.g. temperature exceeds pre-defined threshold) bits 0-1 are for first sensor bits 2-3 are for 2nd sensor (if exists) and so on... Bit 0 is the LSB." ::= { agnt 28 } agnStationClockCard OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), notExist (2), notValid (3), ok (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the station clock card existence and status. notExist - station clock card (piggy) does not exist. notValid - station clock card exists but clock status is not valid. ok - station clock card exists, and its status is OK " ::= { agnt 29 } xcIndexNext OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains an appropriate value to be used for xcIndex when creating entries in the xcTable. The value 0 indicates that no unassigned entries are available. To obtain the xcIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index. After a manager retrieves a value the agent will determine through its local policy when this index value will be made available for reuse." ::= { agnt 30 } --XC Table xcTable OBJECT-TYPE SYNTAX SEQUENCE OF XcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration of system cross-connect entries. The table follows the behavior described in RFC 2515, RFC 1604 regarding the creation deletion and modification of an entry within the table." ::= { agnt 31 } xcEntry OBJECT-TYPE SYNTAX XcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { xcIndex, xcIfIndex1, xcVpi, xcVci, xcIfIndex2 } ::= { xcTable 1} XcEntry ::= SEQUENCE { xcIndex Integer32, xcIfIndex1 Integer32, xcVpi Integer32, xcVci Integer32, xcIfIndex2 Integer32, xcRowStatus RowStatus, xcDescr DisplayString, xcAdminStatus INTEGER, xcOperStatus INTEGER, xcAttachedIfType INTEGER, xcInputPriority Integer32, xcBitMapping Integer32 } xcIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cross Connect Identifier." ::= { xcEntry 1 } xcIfIndex1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The interface Index from the ifTable, which identify one side of the connection." ::= { xcEntry 2 } xcVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The VPI value." ::= { xcEntry 3 } xcVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The VCI value." ::= { xcEntry 4 } xcIfIndex2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The interface Index from the ifTable, which identifies the other side of the connection." ::= { xcEntry 5 } xcRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter allows NMS to create/delete entries of this table." ::= { xcEntry 6 } xcDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "A textual string containing information about the xc entry." ::= { xcEntry 7 } xcAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The desired administrative status of this bi-directional cross-connect." ::= { xcEntry 8 } xcOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational status of this bi-directional cross-connect." ::= { xcEntry 9 } xcAttachedIfType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), free (2), routerAtm (3), lis (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates if the specific VCC is already attached to any interface, and indicates the type of the interface. This object's purpose is to ease the checking to the NMS. notApplicable - used for entries that are not LAN (as HDLC), or when the VCC was attached to a bridge, or when this parameter is irrelevant. free - the LAN VCC wasn't attached yet to any router interface. routerAtm - attached to an ATM router interface. lis - attached to a LIS interface." ::= { xcEntry 10 } xcInputPriority OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-create STATUS current DESCRIPTION "This object is the priority, by which the LAN frames will be internaly sent to the ATM HW. This parameter is applicable if atmNteMdlInputPriorityMechanism=enabled. 1 - Highest priority. Will be the first to be sent to the ATM HW. 4 - Lowest priority. Will be the last to be sent to the ATM HW." ::= { xcEntry 11 } xcBitMapping OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object maps this entry to a bit of an octet string. For ACE2002 this object maps the LAN VCC to the bit of the VLAN Port Lists. If the value is '0' then it means that this VCC is not mapped to a port list or it may be an HDSL entry." ::= { xcEntry 12 } systemModule OBJECT IDENTIFIER ::= { agnt 32 } modlParam OBJECT IDENTIFIER ::= { systemModule 1 } modlParamTable OBJECT-TYPE SYNTAX SEQUENCE OF ModlParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table include parameters for system modules." ::= { modlParam 1 } modlParamEntry OBJECT-TYPE SYNTAX ModlParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { modlParamIndex } ::= { modlParamTable 1} ModlParamEntry ::= SEQUENCE { modlParamIndex Integer32, modlParamReset INTEGER, modlParamSwdlStatus INTEGER, modlParamLeds OCTET STRING } modlParamIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The module index. The index can be the slot number or any other module index as described in the specifications of the device. For Vmux-2100 device, the index will have values of: 1..4 for slots 1..4." ::= { modlParamEntry 1 } modlParamReset OBJECT-TYPE SYNTAX INTEGER { off (2), on (3), factory (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset action to be performed on the module. Set the parameter will be done always to on(3) or factory (4). After performing the Reset operation, Agent will automatically set the parameter to off(2)." ::= { modlParamEntry 2 } modlParamSwdlStatus OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), inProcess (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates whatever the swdl is in process or not." ::= {modlParamEntry 3} modlParamLeds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the LEDs status of the module. Each led is represented by 4 bits where the first 2 bits (left) specify the status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) specify the color : (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY). The order of the LEDS is from top to bottom, left to right: For each row starting from the top, the LEDS are returned from left to right." ::= {modlParamEntry 4} agnNearFarConnection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disconnected (2), connected (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter describes the connection between near-end and far-end agents." ::= { agnt 33 } agnAccess OBJECT IDENTIFIER ::= {agnt 34} agnTelnetAccess OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3), managersOnly (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable accessing the device via Telnet. disable - no one will be allowed to access the device via Telnet. enable - all users are allowed Telnet Access. managersOnly - Only manager stations listed in the manager's list are allowed." ::= { agnAccess 1 } agnWebAccess OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3), managersOnly (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable accessing the device via Web. disable - no one will be allowed to access the device via Web. enable - all users are allowed Web Access. managersOnly - Only manager stations listed in the manager's list are allowed." ::= { agnAccess 2 } systemInterface OBJECT IDENTIFIER ::= { agnt 35 } SysIfEntityType ::= INTEGER -- STATUS current -- DESCRIPTION -- "This type defines the Entity Type. -- The values existing in IANAifType MIB -- should be taken from there only. -- Additional values can be added, starting from 1000 decimal, -- when necessary." { other(1), ethernetLan(6), atm(37), fastEther(62), -- Fast Ethernet (100BaseT) ipForward(142), -- Router teLink(200), bridge(209) } -- Interface Configuration Table ifCreateTable OBJECT-TYPE SYNTAX SEQUENCE OF IfCreateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Interface Configuration Table. This table enables to create inferfaces of Entities." ::= { systemInterface 1 } ifCreateEntry OBJECT-TYPE SYNTAX IfCreateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Interface Configuration table." INDEX { ifCreateEntityType , ifCreateEntityIdx , ifCreateNumber } ::= { ifCreateTable 1 } IfCreateEntry ::= SEQUENCE { ifCreateEntityType SysIfEntityType, ifCreateEntityIdx Integer32, ifCreateNumber Integer32, ifCreateRowStatus RowStatus, ifCreateType IANAifType, ifCreateIndex Integer32 } ifCreateEntityType OBJECT-TYPE SYNTAX SysIfEntityType MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Entity Type." ::= { ifCreateEntry 1 } ifCreateEntityIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Entity Index." ::= { ifCreateEntry 2 } ifCreateNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Interface Number." ::= { ifCreateEntry 3 } ifCreateRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables the user to create/delete entries in this table." ::= { ifCreateEntry 4 } ifCreateType OBJECT-TYPE SYNTAX IANAifType MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the Interface Type." ::= { ifCreateEntry 5 } ifCreateIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the ifIndex of the created Interface." ::= { ifCreateEntry 6 } systemOam OBJECT IDENTIFIER ::= { agnt 36 } systemOamTable OBJECT-TYPE SYNTAX SEQUENCE OF SystemOamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The OAM Configuration Table." ::= { systemOam 1 } systemOamEntry OBJECT-TYPE SYNTAX SystemOamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the OAM table." INDEX { systemOamCnfgIdx } ::= { systemOamTable 1 } SystemOamEntry ::= SEQUENCE { systemOamCnfgIdx Integer32, systemOamFrequency Integer32, systemOamTimeoutCycles Integer32 } systemOamCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg." ::= { systemOamEntry 1} systemOamFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Time in sec. between 2 OAM packets." ::= { systemOamEntry 2 } systemOamTimeoutCycles OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "No. of cycles the agent will send OAM packets without receiving a response from the remote device before declaring that the connection to the remote side is down - Time Out." ::= { systemOamEntry 3 } bitMappingTable OBJECT-TYPE SYNTAX SEQUENCE OF BitMappingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maps bits of an octet string to an interface. For ACE-2002 this table is used to map bits of VLAN port lists to LAN VCC's. This table is the opposite view of the xcTable for xcBitMapping. It is used to ease the bit translation for the NMS." ::= { agnt 38 } bitMappingEntry OBJECT-TYPE SYNTAX BitMappingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in the table describes a correlation of a bit location to an interface. For ACE-2002 - Upon creation of a new LAN VCC the agent will add an entry to this table that will define the bit location for that VCC." INDEX { bitMappingLocation } ::= { bitMappingTable 1} BitMappingEntry ::= SEQUENCE { bitMappingLocation Integer32, bitMappingIndex Integer32 } bitMappingLocation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The bit location in an octet string." ::= { bitMappingEntry 1 } bitMappingIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index or any other index that should be mapped." ::= { bitMappingEntry 2 } bitMappingView OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "A view of the bitMappingTable in one object - each entry in the biMappingTable will have the corresponding Bit of this object (bitMappingLocation) = '1'. For ACE-2002 it is used to describe all the existing LAN VCC's So that the NMS can easily calculate which VCC's can be selected as members for a VLAN, instead of reading all the bitMapping Table." ::= { agnt 39 } --TRAPS --NOTIFICATIONS systemsEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD products." ::= { systems 0 } tftpStatusChangeTrap NOTIFICATION-TYPE OBJECTS { tftpStatus } STATUS current DESCRIPTION "This trap is sent whenever the status of tftp changed." ::= { systemsEvents 1 } agnStatusChangeTrap NOTIFICATION-TYPE OBJECTS {agnIndication } STATUS current DESCRIPTION "This trap is sent whenever the state of the entity the agent is responsible for changed. TDM devices will send agnTestStatus variable to indicate the current test status." ::= { systemsEvents 2 } prtStatusChangeTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent whenever the state of a port changed. Attached, will be parameter/s that indicate the new port status. The attached variables will be specified in the specifications of the products supporting this trap." ::= { systemsEvents 3 } swdlStatusResult NOTIFICATION-TYPE OBJECTS {swdlStatusFileName} STATUS current DESCRIPTION "This notification is sent when Software Down Load is finished. The attached object indicates the File Name." ::= { systemsEvents 4 } intSwdlSlotFileMismatch NOTIFICATION-TYPE OBJECTS {intSwdlFileName} STATUS current DESCRIPTION "This notification is sent when the card in the chosen slot doesn't match the chosen file. The attached object indicates the File Name." ::= { systemsEvents 5 } agnCounterChange NOTIFICATION-TYPE STATUS current DESCRIPTION "This notification is sent when the value of a specific Counter is changed. Agent can send as attached object the updated Counter. For details about this Counter and attached object, see spec of the relevant application." ::= { systemsEvents 6 } prtClkSrcChangeTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon any port clock change." ::= { systemsEvents 7 } moduleFailTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon a module failure." ::= { systemsEvents 8 } moduleInitFailTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon a module initialization failure." ::= { systemsEvents 9 } clkSrcChangeTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon any change in Clock Source." ::= { systemsEvents 10 } agnUploadDataTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon an upload data session termination. For more details see product specification." ::= { systemsEvents 11 } enrollmentTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is a periodically trap, which sent to manager untill Agent get any response (Get or Set) from this manager." ::= { systemsEvents 12 } agnPowerFailureTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon power failure. It is applicable for the following devices: 1. Devices having one PS unit, which sense the failure in advance, and still have time to send this trap before it goes off. 2. Devices having 2 PS units and send this trap in order to notify a failure in one of the units." ::= { systemsEvents 13 } -- -- file :v:\doc\rdv\mib\ver495\radds1.txt -- -- RAD-DS1-MIB DEFINITIONS ::= BEGIN --Title: RAD-DS1 MIB -- -- Copyright 1998 RAD Data Communications, Ltd. -- All Rights Reserved. -- IMPORTS -- PerfCurrentCount, PerfIntervalCount FROM PerfHist-TC-MIB; -- OBJECT-TYPE FROM RFC-1212 -- radWan FROM RAD-GEN-MIB; -- RAD-DS1 MIB --Title: RAD's DS1 INTERFACE MIB --Date: 03.02.98 --By: Ilana Schvetz --File: radds1.mib -- Last updated by Shlomo Shoham 20-Jan-2003 ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4} prtDs1PerfHistory OBJECT IDENTIFIER ::= {ds1Interface 1} -- Extension to the dsx1 current table dsx1XCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1XCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of current statistics entries. This table contains additional objects for the current table." ::= { prtDs1PerfHistory 2 } dsx1XCurrentEntry OBJECT-TYPE SYNTAX Dsx1XCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing additional statistical counters applicable to a particular current table." -- AUGMENTS { dsx1CurrentEntry } INDEX { dsx1CurrentIndex } ::= { dsx1XCurrentTable 1 } Dsx1XCurrentEntry ::= SEQUENCE { dsx1CurrentLOS PerfCurrentCount, dsx1CurrentLOF PerfCurrentCount, dsx1CurrentLOC PerfCurrentCount, dsx1CurrentAIS PerfCurrentCount, dsx1CurrentRAI PerfCurrentCount, dsx1CurrentLOMF PerfCurrentCount, dsx1CurrentFEBE PerfCurrentCount, dsx1CurrentStatus OCTET STRING, dsx1CurrentBPV PerfCurrentCount, dsx1CurrentLOCRCMF PerfCurrentCount, dsx1CurrentLOFC PerfCurrentCount, dsx1CurrentCRCErrors PerfCurrentCount } dsx1CurrentLOS OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOS seconds, encountered by a DS1 interface in the current 15 minute interval." ::= { dsx1XCurrentEntry 1 } dsx1CurrentLOF OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOF seconds, encountered by a DS1 interface in the current 15 minute interval." ::= { dsx1XCurrentEntry 2 } dsx1CurrentLOC OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION " Loss Of Cell delineation. Counts number of cells the ATM UNI cells receiver lost cells delineation ." ::= { dsx1XCurrentEntry 3 } dsx1CurrentAIS OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of AIS seconds, encountered by a DS1 interface in the current 15 minute interval." ::= { dsx1XCurrentEntry 4 } dsx1CurrentRAI OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Alarm Indication: Transmitted in the outgoing direction (toward the PABX) over FDL bits when the DS1 device detected an incoming Loss Of Frame. Received from the far end (PABX) over FDL when it detects a Loss of frame." ::= { dsx1XCurrentEntry 5 } dsx1CurrentLOMF OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of Multi-Frame sequence in E1 time slot 16." ::= { dsx1XCurrentEntry 6 } dsx1CurrentFEBE OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Far End Block Errors, as reported in the first bit of frames 13 and 15, on multiframe E1 lines with CRC4, in the current 15 minute interval." ::= { dsx1XCurrentEntry 7 } dsx1CurrentStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { dsx1XCurrentEntry 8 } dsx1CurrentBPV OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of BPVs (Bi-Polar Violations) encountered by a DS1 interface in the current 15 minute interval." ::= { dsx1XCurrentEntry 9 } dsx1CurrentLOCRCMF OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of CRC4 Multi-Frame sequence in E1. encountered in the current 15 minute interval" ::= { dsx1XCurrentEntry 10 } dsx1CurrentLOFC OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Counts the number of loss of frame events measured. encountered in the current 15 minute interval" ::= { dsx1XCurrentEntry 11 } dsx1CurrentCRCErrors OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Counts the number of CRC error events, encountered in the current 15 minute interval." ::= { dsx1XCurrentEntry 12 } -- Interval table dsx1XIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1XIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A list of Interval entries. This table contains additional objects for the interval table." ::= { prtDs1PerfHistory 3 } dsx1XIntervalEntry OBJECT-TYPE SYNTAX Dsx1XIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing additional statistical counters applicable to a particular interval table." -- AUGMENTS { dsx1IntervalEntry } INDEX { dsx1IntervalIndex, dsx1IntervalNumber } ::= { dsx1XIntervalTable 1 } Dsx1XIntervalEntry ::= SEQUENCE { dsx1IntervalLOS PerfIntervalCount, dsx1IntervalLOF PerfIntervalCount, dsx1IntervalLOC PerfIntervalCount, dsx1IntervalAIS PerfIntervalCount, dsx1IntervalRAI PerfIntervalCount, dsx1IntervalLOMF PerfIntervalCount, dsx1IntervalFEBE PerfIntervalCount, dsx1IntervalStatus OCTET STRING, dsx1IntervalBPV PerfIntervalCount, dsx1IntervalLOCRCMF PerfIntervalCount, dsx1IntervalLOFC PerfIntervalCount } dsx1IntervalLOS OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOS seconds , encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx1XIntervalEntry 1 } dsx1IntervalLOF OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of OOF seconds, encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx1XIntervalEntry 2 } dsx1IntervalLOC OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION " Loss Of Cell delineation. Counts number of cells the ATM UNI cells receiver lost cells delineation ." ::= { dsx1XIntervalEntry 3 } dsx1IntervalAIS OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of AIS seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx1XIntervalEntry 4 } dsx1IntervalRAI OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Alarm Indication: Transmitted in the outgoing direction (toward the PABX) over FDL bits when the DS1 device detected an incoming Loss Of Frame. Received from the far end (PABX) over FDL when it detects a Loss of frame." ::= { dsx1XIntervalEntry 5 } dsx1IntervalLOMF OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of Multi-Frame sequence in E1 time slot 16." ::= { dsx1XIntervalEntry 6 } dsx1IntervalFEBE OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "Far End Block Errors, as reported in the first bit of frames 13 and 15, on multiframe E1 lines with CRC4, in one of the previous 96, individual, 15 minute intervals." ::= { dsx1XIntervalEntry 7 } dsx1IntervalStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { dsx1XIntervalEntry 8 } dsx1IntervalBPV OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of BPV (Bi-Polar Violations) encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx1XIntervalEntry 9 } dsx1IntervalLOCRCMF OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of CRC4 Multi-Frame sequence in E1." ::= { dsx1XIntervalEntry 10 } dsx1IntervalLOFC OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "Counts the number of loss of frame events measured in one of the previous 96, individual 15 minute, intervals." ::= { dsx1XIntervalEntry 11 } -- Extension to the dsx1 Total table dsx1XTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1XTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Total statistics entries. This table contains additional objects for the Total table." ::= { prtDs1PerfHistory 4 } dsx1XTotalEntry OBJECT-TYPE SYNTAX Dsx1XTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing additional statistical counters applicable to a particular current table." -- AUGMENTS { dsx1CurrentEntry } INDEX { dsx1TotalIndex } ::= { dsx1XTotalTable 1 } Dsx1XTotalEntry ::= SEQUENCE { dsx1TotalBPV PerfTotalCount, dsx1TotalLOFC PerfTotalCount } dsx1TotalBPV OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of BPV (Bi-Polar Violations) encountered by a DS1 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx1XTotalEntry 9 } dsx1TotalLOFC OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number loss of frames encountered by a DS1 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx1XTotalEntry 11 } -- Extension to the DS1 Configuration Table dsx1XConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1XConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An extension to the DS1 Configuration table." ::= { ds1Interface 2 } dsx1XConfigEntry OBJECT-TYPE SYNTAX Dsx1XConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing additional configuration parameters." -- AUGMENTS { dsx1ConfigTable } INDEX { dsx1LineIndex } ::= { dsx1XConfigTable 1 } Dsx1XConfigEntry ::= SEQUENCE { dsx1IdleCode Integer32, dsx1LineMode INTEGER, dsx1dBTxGain INTEGER, dsx1RxSensitivity INTEGER, dsx1RestoreTime INTEGER, dsx1TcFirstSignal Integer32, dsx1TcSignal Integer32, dsx1TcPattern Integer32, dsx1Scramble INTEGER, dsx1LineAdaptiveTimingMode INTEGER, dsx1TxClockSource INTEGER, dsx1AisEnable INTEGER, dsx1TsEchoCancel OCTET STRING, dsx1EchoCancelerModule INTEGER, dsx1PortFunction INTEGER, dsx1PortMultiplier INTEGER, dsx1LeasedLine INTEGER, dsx1CsuLoop INTEGER } dsx1IdleCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Byte pattern of the data received/transmitted in the E1T1 framer idle timeslots. Valid range: (0 - FF HEX)." ::= { dsx1XConfigEntry 1 } dsx1LineMode OBJECT-TYPE SYNTAX INTEGER { csu(1), dsu(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "T1 device operation mode. Valid for T1 only." ::= { dsx1XConfigEntry 2 } dsx1dBTxGain OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), neg75dB (2), neg15dB (3), neg225dB (4), zerodB (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Transmit line Gain for T1 CSU line mode." ::= { dsx1XConfigEntry 3 } dsx1RxSensitivity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), neg10dB (2), neg32dB (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determine the maximum attenuation of the receive signal that can be compensated for by the interface receive path. Not applicable for T1." ::= { dsx1XConfigEntry 4 } dsx1RestoreTime OBJECT-TYPE SYNTAX INTEGER { other(1), sec1(2), sec10(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to change the sync. algorithms to reduce the time required for the port to return to normal operation after a RED alarm." ::= { dsx1XConfigEntry 5 } dsx1TcFirstSignal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trunk conditioning signal - value to be sent as a signal during the first 2.5 seconds after alarm detection. Range is 0x0..0xF. 0xFF is a NULL value. Valid for T1 only." ::= { dsx1XConfigEntry 6 } dsx1TcSignal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trunk conditioning signal value after alarm detection. Range is 0x1..0xF for E1, and 0x0..0xF for T1." ::= { dsx1XConfigEntry 7 } dsx1TcPattern OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trunk conditioning data pattern to be sent upon a DS0 fail. Range is 0x0..0xFF." ::= { dsx1XConfigEntry 8 } dsx1Scramble OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), notActive (2), active (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Scrambling is an operation that randomizes the bits of the payload of the ATM cell by a polynom. This operation helps with the error detection mechanism of the HEC. Not applicable for E1. active - will scramble/descramble the payload ATM cell notActive - will not scramble/descramble. " ::= { dsx1XConfigEntry 9 } dsx1LineAdaptiveTimingMode OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables end to end clock synchronization. Default value - off." ::= { dsx1XConfigEntry 10 } dsx1TxClockSource OBJECT-TYPE SYNTAX INTEGER { loopTiming(1), localTiming(2), throughTiming(3), adaptive(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The source of Transmit Clock. 'loopTiming' indicates that the recovered receive clock is used as the transmit clock. 'localTiming' indicates that a local clock source is used or when an external clock is attached to the box containing the interface. 'throughTiming' indicates that recovered receive clock from another interface is used as the transmit clock. 'adaptive' indicates that the clock is recovered according to the received data flow rate. " ::= { dsx1XConfigEntry 11 } dsx1AisEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disable(2), enable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/ disable AIS transmit when Ethernet cable (for TDMoIP) is out (disconnected)." ::= { dsx1XConfigEntry 12 } dsx1TsEchoCancel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines for each TS whether Echo-Cancellation is on. Each bit represents one TS as follow: First octet bit'0' = TS#1, bit'7' = TS#8, .. 2nd octet bit'0' = TS#9,.., 4th octet bit'7' = TS#32. Octets and bits order is from left to right: [31,30,..24] [23..16] [15..8] [7..0] MSB LSB MSB LSB MSB LSB MSB LSB For each bit values are: 0 - Echo-Cancellation off. 1 - Echo-Cancellation on." ::= { dsx1XConfigEntry 13 } dsx1EchoCancelerModule OBJECT-TYPE SYNTAX INTEGER { notExist(2), exist(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates whether echo-cancellation module exists for this line." ::= { dsx1XConfigEntry 14 } dsx1PortFunction OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), uni (2), ces (3), ima (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object determines the ATM Mode over the physical port. uni - The port will function as an ATM UNI. ces - The port will function as a CES. ima - The port will function as an IMA-ATM." ::= { dsx1XConfigEntry 15 } dsx1PortMultiplier OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r56 (2), r64 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object determines the data rate of each TS (Kbps units). This parameter is applicable for T1 only." ::= { dsx1XConfigEntry 16 } dsx1LeasedLine OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether Line mode is regular (non Leased Line mode) or transparent (Leased Line mode)." ::= { dsx1XConfigEntry 17 } dsx1CsuLoop OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), local (2), transparent (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether CSU loop will be done locally (by IPmux) or will be transferred to the TDM device." ::= { dsx1XConfigEntry 18 } -- END -- -- file :v:\doc\rdv\mib\Before~1\radds3.txt -- -- RAD-DS3-MIB DEFINITIONS ::= BEGIN --Title: RAD-DS3 MIB -- -- Copyright 1993 RAD Data Communications, Ltd. -- All Rights Reserved. -- It is RAD's intent to encourage the widespread use of -- this Specification in connection with the management of -- RAD products. RAD grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of RAD products. -- This Specification is supplied "as is," and RAD makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. -- IMPORTS -- Gauge32 FROM SNMPv2-SMI -- ifIndex FROM SNMPv2-TC -- OBJECT-TYPE FROM SNMPv2-SMI -- radWan FROM RAD-GEN-MIB; -- RAD-DS3 MIB --Title: RAD's DS3 INTERFACE MIB --Version: 1.0 --Date: 13.10.96 --By: Yair Arian --File: ds3.mib -- --Last update: 27.01.98 by Ilana ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3} prtDs3PerfHistory OBJECT IDENTIFIER ::= {ds3Interface 1} -- The DS3 Interface Table prtSDs3IfTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDs3IfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 interface table." ::= { prtDs3PerfHistory 1 } prtDs3IfEntry OBJECT-TYPE SYNTAX PrtDs3IfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3 interface table." INDEX { ifIndex } ::= { prtSDs3IfTable 1 } PrtDs3IfEntry ::= SEQUENCE { prtDs3IfTimeElapsed Integer32, prtDs3IfValidIntervals Integer32 } prtDs3IfTimeElapsed OBJECT-TYPE SYNTAX Integer32 (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the near end current error- measurement period." ::= { prtDs3IfEntry 1 } prtDs3IfValidIntervals OBJECT-TYPE SYNTAX Integer32 (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online." ::= { prtDs3IfEntry 2 } -- The DS3 Current Table -- The DS3 Current table contains various statistics being -- collected for the current 15 minute interval. prtDs3CurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDs3CurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 Current table." ::= { prtDs3PerfHistory 2 } prtDs3CurrentEntry OBJECT-TYPE SYNTAX PrtDs3CurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3 Current table." INDEX { ifIndex } ::= { prtDs3CurrentTable 1 } PrtDs3CurrentEntry ::= SEQUENCE { prtDs3CurrentLOS Gauge32, prtDs3CurrentOOF Gauge32, prtDs3CurrentLOC Gauge32, prtDs3CurrentAIS Gauge32, prtDs3CurrentRDI Gauge32, prtDs3CurrentUAS Gauge32, prtDs3CurrentBIP Gauge32, prtDs3CurrentFEBE Gauge32, prtDs3CurrentSLM Gauge32, prtDs3CurrentSES Gauge32, prtDs3CurrentES Gauge32, prtDs3CurrentBitParity Gauge32, prtDs3CurrentPlcpLOF Gauge32, prtDs3CurrentPlcpRAI Gauge32, prtDs3CurrentPlcpBIP Gauge32, prtDs3CurrentPlcpFEBE Gauge32, prtDs3CurrentBPV Gauge32, prtDs3CurrentLCE Gauge32, prtDs3CurrentStatus OCTET STRING } prtDs3CurrentLOS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOS seconds, encountered by a DS3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 1 } prtDs3CurrentOOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of OOF seconds, encountered by a DS3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 2 } prtDs3CurrentLOC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOC seconds, encountered by a DS3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 3 } prtDs3CurrentAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of AIS seconds, encountered by a DS3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 4 } prtDs3CurrentRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of RDI seconds, encountered by a DS3 interface." ::= { prtDs3CurrentEntry 5 } prtDs3CurrentUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of UAS, encountered by a SONET interface." ::= { prtDs3CurrentEntry 6 } prtDs3CurrentBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of BIP errors, encountered by a DS3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 7 } prtDs3CurrentFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of FEBE errors, encountered by a DS3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 8 } prtDs3CurrentSLM OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SLM seconds, encountered by an E3 (only ) interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 9 } prtDs3CurrentSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SES encountered by a E3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 10 } prtDs3CurrentES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " The number of Errored Seconds, encountered by a DS3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 11 } prtDs3CurrentBitParity OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Bit Parity Error counter. Relevant to T3 only." ::= { prtDs3CurrentEntry 12 } prtDs3CurrentPlcpLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOF seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals. This counter is relevant for plcpInternal(5) or plcpExternal(6) configuration If frame types only." ::= { prtDs3CurrentEntry 13 } prtDs3CurrentPlcpRAI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Receiving Yellow/Remote Alarm Indication. This counter is relevant for PLCP (external/internal) frame types only." ::= { prtDs3CurrentEntry 14 } prtDs3CurrentPlcpBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " The counter associated with the number of BIP errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only." ::= { prtDs3CurrentEntry 15 } prtDs3CurrentPlcpFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " The counter associated with the number of FEBE errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only." ::= { prtDs3CurrentEntry 16 } prtDs3CurrentBPV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of BPVs (Bi-Polar Violations) , encountered by a DS3 interface in the current 15 minute interval. This object is relevant only for Electrical Line of Fomi-E3/T3." ::= { prtDs3CurrentEntry 17 } prtDs3CurrentLCE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of LCE (Link Code Errors) encountered by a DS3 interface in the current 15 minute interval. This object is relevant only for Optical Links of Fomi-E3/T3." ::= { prtDs3CurrentEntry 18 } prtDs3CurrentStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { prtDs3CurrentEntry 19 } -- The DS3 interface Interval -- The DS3 Interval Table contains various statistics -- collected by the Interface over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. prtDs3IntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDs3IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 Interval table." ::= { prtDs3PerfHistory 3 } prtDs3IntervalEntry OBJECT-TYPE SYNTAX PrtDs3IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3 Interval table." INDEX { ifIndex, prtDs3IntervalNumber } ::= { prtDs3IntervalTable 1 } PrtDs3IntervalEntry ::= SEQUENCE { prtDs3IntervalNumber Integer32, prtDs3IntervalLOS Gauge32, prtDs3IntervalOOF Gauge32, prtDs3IntervalLOC Gauge32, prtDs3IntervalAIS Gauge32, prtDs3IntervalRDI Gauge32, prtDs3IntervalUAS Gauge32, prtDs3IntervalBIP Gauge32, prtDs3IntervalFEBE Gauge32, prtDs3IntervalSLM Gauge32, prtDs3IntervalSES Gauge32, prtDs3IntervalES Gauge32, prtDs3IntervalBitParity Gauge32, prtDs3IntervalPlcpLOF Gauge32, prtDs3IntervalPlcpRAI Gauge32, prtDs3IntervalPlcpBIP Gauge32, prtDs3IntervalPlcpFEBE Gauge32, prtDs3IntervalBPV Gauge32, prtDs3IntervalLCE Gauge32, prtDs3IntervalStatus OCTET STRING } prtDs3IntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { prtDs3IntervalEntry 1 } prtDs3IntervalLOS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOS seconds , encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 2 } prtDs3IntervalOOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of OOF seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 3 } prtDs3IntervalLOC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOC seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 4 } prtDs3IntervalAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of AIS seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 5 } prtDs3IntervalRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of RDI seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 6 } prtDs3IntervalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of UAS, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 7 } prtDs3IntervalBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of BIP errors, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 8 } prtDs3IntervalFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of FEBE errors, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 9 } prtDs3IntervalSLM OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SLM seconds, encountered by an E3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 10 } prtDs3IntervalSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SES encountered by a E3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 11 } prtDs3IntervalES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " The number of Errored Seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 12 } prtDs3IntervalBitParity OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Bit Parity Error counter. Relevant to T3 only." ::= { prtDs3IntervalEntry 13 } prtDs3IntervalPlcpLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOF seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals. This counter is relevant for plcpInternal(5) or plcpExternal(6) configuration If frame types only." ::= { prtDs3IntervalEntry 14 } prtDs3IntervalPlcpRAI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Receiving Yellow/Remote Alarm Indication. This counter is relevant for PLCP (external/internal) frame types only." ::= { prtDs3IntervalEntry 15 } prtDs3IntervalPlcpBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " The counter associated with the number of BIP errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only." ::= { prtDs3IntervalEntry 16 } prtDs3IntervalPlcpFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " The counter associated with the number of FEBE errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only." ::= { prtDs3IntervalEntry 17 } prtDs3IntervalBPV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of BPVs (Bi-Polar Violations) , encountered by a DS3 interface in the specified 15 minute interval. This object is relevant only for Electrical Line of Fomi-E3/T3." ::= { prtDs3IntervalEntry 18 } prtDs3IntervalLCE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of LCE (Link Code Errors) encountered by a DS3 interface in the specified 15 minute interval. This object is relevant only for Optical Links of Fomi-E3/T3." ::= { prtDs3IntervalEntry 19 } prtDs3IntervalStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { prtDs3IntervalEntry 20 } -- the DS3 Total table prtDs3TotalTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDs3TotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A list of Total entries." ::= { prtDs3PerfHistory 4 } prtDs3TotalEntry OBJECT-TYPE SYNTAX PrtDs3TotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of Total table." INDEX { ifIndex } ::= { prtDs3TotalTable 1 } PrtDs3TotalEntry ::= SEQUENCE { prtDs3TotalUAS Gauge32, prtDs3TotalBPV Gauge32, prtDs3TotalLCE Gauge32 } prtDs3TotalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of UASs (Unavailable Seconds) , encountered by a DS3 interface in the previous 96 intervals. Invalid 15 minute intervals count as 0." ::= { prtDs3TotalEntry 6 } prtDs3TotalBPV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of BPVs (Bi-Polar Violations) , encountered by a DS3 interface in the previous 96 intervals. Invalid 15 minute intervals count as 0." ::= { prtDs3TotalEntry 17 } prtDs3TotalLCE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of LCE (Link Code Errors) encountered by a DS3 interface in the previous 96 intervals. Invalid 15 minute intervals count as 0." ::= { prtDs3TotalEntry 18 } -- END -- -- file :v:\doc\rdv\mib\ver495\brggen.txt -- --Version 4.95 --Initial Version: 4.0 --Date: 16.10.94 --By: Debby Koren & Orly Nicklass --File: BRGgen.txt --Last Updated by Ilana Schvetz 15-Jan-2003. genBridge OBJECT IDENTIFIER ::= {radBridges 1 } -- At the end of the MIB there is a definition of all RAD general traps for bridges. radBridgeAction OBJECT-TYPE SYNTAX INTEGER { reset(1), sendNetworkTab(2), deleteNetworkTab(3), sendRoutingTab(4), -- Level II deleteRoutinTab(5), sendLanTab(6), deleteLanTab(7), deleteArpTab(8), sendArpTab(9), deleteRouteTab(10), -- Level III sendRouteTab(11), deactivateAllMasks(12), saveAllActiveMasks(13), loadAndActivateAllMasksFromNVRAM(14), clearAllMasksFromNVRAM(15), defaultConfig(16), resetNVRAM(17), clearIPNVRAM(18), noOp(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable enables the operator to perform one of the specified actions on the tables maintained by the network device. Send actions are not currently implemented. Not all actions can be performed on all bridges." ::= { genBridge 1 } radBridgeInactiveArpTimeOut OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the maximum time period that can pass between ARP requests concerning an entry in the ARP table. After this time period, the entry is deleted from the table." ::= { genBridge 2 } -- radBridgeMaskTab defines the format of RAD Bridge OLD masking tables radBridgeMaskTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeMaskEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Mask tables enable definition of forwarding restrictions and control of message flow in the internetwork. Each entry in this table defines a mask statement consisting of up to three mask definitions and an action defined by radBridgeMaskOper. Different types of mask entries are supported, as defined by radBridgeMaskType." ::= { genBridge 3 } radBridgeMaskEntry OBJECT-TYPE SYNTAX RadBridgeMaskEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table radBridgeMaskTable." INDEX { radBridgeMaskType, radBridgeMaskIfIndex, radBridgeMaskNum } ::= { radBridgeMaskTable 1 } RadBridgeMaskEntry ::= SEQUENCE { radBridgeMaskType INTEGER, radBridgeMaskIfIndex Integer32, radBridgeMaskNum Integer32, radBridgeMaskDest INTEGER, radBridgeMaskPat1 OCTET STRING, radBridgeMaskActiveBit1 OCTET STRING, radBridgeMaskFrom1 INTEGER, radBridgeMaskOffset1 Integer32, radBridgeMaskCond1 INTEGER, radBridgeMaskPat2 OCTET STRING, radBridgeMaskActiveBit2 OCTET STRING, radBridgeMaskFrom2 INTEGER, radBridgeMaskOffset2 Integer32, radBridgeMaskCond2 INTEGER, radBridgeMaskPat3 OCTET STRING, radBridgeMaskActiveBit3 OCTET STRING, radBridgeMaskFrom3 INTEGER, radBridgeMaskOffset3 Integer32, radBridgeMaskCond3 INTEGER, radBridgeMaskOper INTEGER } radBridgeMaskType OBJECT-TYPE SYNTAX INTEGER { tx(1), rx(2), compress(3), priority(4), loadSharing(5), facs(6), codConnect(7), codDisconnect(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the type of mask entry." ::= { radBridgeMaskEntry 1 } radBridgeMaskIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the if Index of the interface to which the mask is applied." ::= { radBridgeMaskEntry 2 } radBridgeMaskNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Mask entry number, defined by its line number in the mask table." ::= { radBridgeMaskEntry 3 } radBridgeMaskDest OBJECT-TYPE SYNTAX INTEGER { unassigned-cond (1), broadcast-msge (2), multicast-msge (3), all-msge(4), none(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the type of destination address carried by the frame to which the mask will be applied. Unassigned-condition deactivates the mask entry." ::= { radBridgeMaskEntry 4 } radBridgeMaskPat1 OBJECT-TYPE SYNTAX OCTET STRING -- (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Describes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern." ::= { radBridgeMaskEntry 5 } radBridgeMaskActiveBit1 OBJECT-TYPE SYNTAX OCTET STRING -- (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the positions of the wild card characters (*) in the radBridgeMaskPat1 field." ::= { radBridgeMaskEntry 6 } radBridgeMaskFrom1 OBJECT-TYPE SYNTAX INTEGER { mac(1), llc(2), net(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Offset base of radBridgeMaskPat1 within the frame. Net can be in some cases the data start point." ::= { radBridgeMaskEntry 7 } radBridgeMaskOffset1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the radBridgeMaskPat1 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm1.The mask offset is an even decimal number in the range of 0 to 1518." ::= { radBridgeMaskEntry 8 } radBridgeMaskCond1 OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset1 the packet contains data that matches the content of radBridgeMaskPat1. false - Condition is valid if at the position specified by radBridgeMaskOffset1 the packet contains data that does not match the content of radBridgeMaskPat1." ::= { radBridgeMaskEntry 9 } radBridgeMaskPat2 OBJECT-TYPE SYNTAX OCTET STRING -- (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Describes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern." ::= { radBridgeMaskEntry 10 } radBridgeMaskActiveBit2 OBJECT-TYPE SYNTAX OCTET STRING -- (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the positions of the wild card characters (*) in the radBridgeMaskPat2 field." ::= { radBridgeMaskEntry 11 } radBridgeMaskFrom2 OBJECT-TYPE SYNTAX INTEGER { mac (1), llc (2), net(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Offset base of radBridgeMaskPat2 within the frame. Net can be in some cases the data start point." ::= { radBridgeMaskEntry 12 } radBridgeMaskOffset2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the radBridgeMaskPat2 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm2.The mask offset is an even decimal number in the range of 0 to 1518." ::= { radBridgeMaskEntry 13 } radBridgeMaskCond2 OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset2 the packet contains data that matches the content of radBridgeMaskPat2. false - Condition is valid if at the position specified by radBridgeMaskOffset2 the packet contains data that does not match the content of radBridgeMaskPat2." ::= { radBridgeMaskEntry 14 } radBridgeMaskPat3 OBJECT-TYPE SYNTAX OCTET STRING -- (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Describes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern." ::= { radBridgeMaskEntry 15 } radBridgeMaskActiveBit3 OBJECT-TYPE SYNTAX OCTET STRING -- (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the positions of the wild card characters (*) in the radBridgeMaskPat3 field." ::= { radBridgeMaskEntry 16 } radBridgeMaskFrom3 OBJECT-TYPE SYNTAX INTEGER { mac (1), llc (2), net (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Offset base of radBridgeMaskPat3 within the frame. Net can be in some cases the data start point." ::= { radBridgeMaskEntry 17 } radBridgeMaskOffset3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the radBridgeMaskPat3 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm3. The mask offset is an even decimal number in the range of 0 to 1518." ::= { radBridgeMaskEntry 18 } radBridgeMaskCond3 OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset3 the packet contains data that matches the content of radBridgeMaskPat3 false - Condition is valid if at the position specified by radBridgeMaskOffset3 the packet contains data that does not match the content of radBridgeMaskPat3." ::= { radBridgeMaskEntry 19 } radBridgeMaskOper OBJECT-TYPE SYNTAX INTEGER { block (1), forward (2), route (3), forward-route (4), high-priority (5), noOp(6), delete(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of action to be taken if the frame meets the conditions of the mask. noOp = disabled (mask remains on list, but is not active) delete = mask is removed from the list. " ::= { radBridgeMaskEntry 20 } radBridgeCOD OBJECT IDENTIFIER ::= {genBridge 4 } radBridgeCODParamTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeCODEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of COD parameters " ::= { radBridgeCOD 1} radBridgeCODEntry OBJECT-TYPE SYNTAX RadBridgeCODEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each radBridgeCODEntry consists of the following parameters" INDEX {radBridgeCODIfIndex} ::= { radBridgeCODParamTable 1 } RadBridgeCODEntry ::= SEQUENCE { radBridgeCODIfIndex Integer32, radBridgeCODManualConnect INTEGER, radBridgeCODMode INTEGER, radBridgeCODConnectDelay Integer32, radBridgeCODisConnectDelay Integer32, radBridgeCODImplicitSwitch INTEGER, radBridgeCODNumAccess Counter32, radBridgeCODTotalConnecTime Integer32 } radBridgeCODIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface to which this COD entry is applicable." ::= { radBridgeCODEntry 1 } radBridgeCODManualConnect OBJECT-TYPE SYNTAX INTEGER { connect(1), disconnect(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The management station can start connection manually by setting this parameter" ::= { radBridgeCODEntry 2 } radBridgeCODMode OBJECT-TYPE SYNTAX INTEGER { answer(1), originate(2), disable(3), answerAndOriginate(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "In answer mode only one incoming call may be accepted at a time. Other nodes attempting to access the local modem will receive a busy signal until the connection is terminated. (Answer mode has no difficulty supporting multiple remote connections to one local port, as blocking multiple incoming calls is just a modem function. Originate mode, on the other hand will only support a single local port to remote port connection). The disable parameter disables the COD utility for this interface. Choosing any other mode will enable the COD utility." ::= { radBridgeCODEntry 3 } radBridgeCODConnectDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The connect delay defines the minimum time period that the link must stay disconnected, between 2 succesive connections (in seconds)." ::= { radBridgeCODEntry 4 } radBridgeCODisConnectDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The disconnect delay defines the minimum time period the link must stay connected, between 2 succesive disconnections (in seconds)." ::= { radBridgeCODEntry 5 } radBridgeCODImplicitSwitch OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The inplicit switch allows the user to ignore implicit triggers provided by the COD software." -- DEFVAL { 1 } ::= { radBridgeCODEntry 6 } radBridgeCODNumAccess OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of successful connections that have been established since the COD has been reset." ::= { radBridgeCODEntry 7} radBridgeCODTotalConnecTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The sum of all the connect time intervals since the COD was reset." ::= { radBridgeCODEntry 8} radBridgeCODTimeTriggerTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeCODTimeTriggerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of COD parameters " ::= { radBridgeCOD 2 } radBridgeCODTimeTriggerEntry OBJECT-TYPE SYNTAX RadBridgeCODTimeTriggerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each radBridgeCODTimeTriggerEntry consists of the following parameters" INDEX { radBridgeCODTimeIfIndex, radBridgeCODDay, radBridgeCODTimeTriggerNum } ::= { radBridgeCODTimeTriggerTable 1 } RadBridgeCODTimeTriggerEntry ::= SEQUENCE { radBridgeCODTimeIfIndex Integer32, radBridgeCODDay INTEGER, radBridgeCODTimeTriggerNum Integer32, radBridgeCODTimeTriggerFrom DisplayString, radBridgeCODTimeTriggerTo DisplayString, radBridgeCODTimeTriggerStatus INTEGER } radBridgeCODTimeIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface to which this COD Time Trigger entry is applicable." ::= { radBridgeCODTimeTriggerEntry 1} radBridgeCODDay OBJECT-TYPE SYNTAX INTEGER { mon(1), tue(2), wed(3), thu(4), fri(5), sat(6), sun(7) } MAX-ACCESS read-only STATUS current DESCRIPTION " The day of the week in which the dial up connection operates." ::= { radBridgeCODTimeTriggerEntry 2 } radBridgeCODTimeTriggerNum OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION " Every day of the week the user can configure 3 dial up connections." ::= { radBridgeCODTimeTriggerEntry 3 } radBridgeCODTimeTriggerFrom OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time to start Dial Up connection, in format hh:mm." ::= {radBridgeCODTimeTriggerEntry 4 } radBridgeCODTimeTriggerTo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time to terminate Dial Up connection, in format HH:MM." ::= {radBridgeCODTimeTriggerEntry 5 } radBridgeCODTimeTriggerStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of a table entry." ::= { radBridgeCODTimeTriggerEntry 6 } radBridgeCODTraffic OBJECT IDENTIFIER ::= { radBridgeCOD 3} radBridgeCODTrafficTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeCODTrafficEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of COD Traffic trigger " ::= { radBridgeCODTraffic 1 } radBridgeCODTrafficEntry OBJECT-TYPE SYNTAX RadBridgeCODTrafficEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each radBridgeCODTrafficEntry consists of the following parameters." INDEX {radBridgeCODProtocolType} ::= { radBridgeCODTrafficTable 1} RadBridgeCODTrafficEntry ::= SEQUENCE { radBridgeCODProtocolType INTEGER, radBridgeCODTrafficTriggerStatus INTEGER } radBridgeCODProtocolType OBJECT-TYPE SYNTAX INTEGER { ip(1), ipx(2), other(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Protocol Type of the Traffic Table" ::= { radBridgeCODTrafficEntry 1 } radBridgeCODTrafficTriggerStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Command of Status of the Protocol Traffic Trigger" ::= { radBridgeCODTrafficEntry 2 } radBridgeCODRemoteIPAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION " This is the Remote IP Address" ::= { radBridgeCODTraffic 2 } radBridgeCODIPMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION " This is the Mask of the Remote IP Address" ::= { radBridgeCODTraffic 3 } radBridgeCODTrafficTriggerProtType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Protocol Type for the User Defined Protocol Traffic Trigger (3)." ::= { radBridgeCODTraffic 4 } --COD Condition table radBridgeCODCondTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeCODCondEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of COD Condition parameters " ::= { radBridgeCOD 4} radBridgeCODCondEntry OBJECT-TYPE SYNTAX RadBridgeCODCondEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each radBridgeCODCondEntry consists of the following parameters" INDEX {radBridgeCODCondIfIndex} ::= { radBridgeCODCondTable 1 } RadBridgeCODCondEntry ::= SEQUENCE { radBridgeCODCondIfIndex Integer32, radBridgeCODOriginateConnectCondition INTEGER, radBridgeCODOriginateDisConnectCondition INTEGER, radBridgeCODOriginateDisConnectDelay Integer32, radBridgeCODAnswerConnectCondition INTEGER, radBridgeCODSpecificOnTrafficOIDCondition OBJECT IDENTIFIER, radBridgeCODDisConnectMinimunFramesNumber Integer32 } radBridgeCODCondIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface, this COD entry is applicable to." ::= { radBridgeCODCondEntry 1 } radBridgeCODOriginateConnectCondition OBJECT-TYPE SYNTAX INTEGER { onPowerOn (1), whenAnyStationOnLan (2), onTraffic (3), onManualConnect (4) } MAX-ACCESS read-write STATUS current DESCRIPTION " This condition, allows the user to specify the condition under which the link is connected. The options are onPowerOn - On power on. whenAnyStationOnLan - When any station on lan. onTraffic - On traffic. The user can specify the condition/s for connection. The connection will be defined in CODSpecificOnTrafficConditionOID . onManualConnect - depends on radBridgeCODManualConnect OBJECT-TYPE (=connect). " ::= { radBridgeCODCondEntry 2 } radBridgeCODOriginateDisConnectCondition OBJECT-TYPE SYNTAX INTEGER { noStationOnLan (1), onTraffic (2), onDelayFromConnectionOnRequest (3), onManualDisConnect (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This condition allows the user to specify the condition under which the link is disconnected. The options are: noStationOnLan - When there is no station on lan. Counts 15 minutes from the point the last frame from lan has been received. If no frame have been transmitted on lan by the end of this period, disconnect the connection. onTraffic - On traffic. The user can specify the condition/s for disconnection. The disconnection will be defined in CODSpecificOnTrafficConditionOID . onDelayFromConnectionOnRequest - On Delay From Connection On Request . The delay time period will be defined in CODOriginateDisConnectDelay . onManualDisConnect - depends on radBridgeCODManualConnect OBJECT-TYPE (=disconnect). " ::= { radBridgeCODCondEntry 3 } radBridgeCODOriginateDisConnectDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Delay time in seconds. " ::= { radBridgeCODCondEntry 4 } radBridgeCODAnswerConnectCondition OBJECT-TYPE SYNTAX INTEGER { onPowerOn (1), whenAnyStationOnLan (2), onTraffic (3), onManualConnect (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "CODCondAnswerConnect allows the user to specify the condition under which the link is connected. The options are: onPowerOn - On power on. whenAnyStationOnLan - When any station on lan. onTraffic - On traffic. The user can specify the condition/s for connection. The connection will be defined in CODSpecificOnTrafficConditionOID . onManualConnect - depends on radBridgeCODManualConnect OBJECT-TYPE . " ::= { radBridgeCODCondEntry 5 } radBridgeCODSpecificOnTrafficOIDCondition OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "A reference to a specific entry in the radBridgeMaskTable, which describes the particular COD condition . If Connect or Disconnect Conditions are not onTraffic, its value should be set to the OBJECT IDENTIFIER { 0 0 }. " ::= { radBridgeCODCondEntry 6 } radBridgeCODDisConnectMinimunFramesNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Frames rate." ::= { radBridgeCODCondEntry 7 } --The IPX following objects define the Spoofing radBridgeIPX OBJECT IDENTIFIER ::= {genBridge 5 } radBridgeIPXdriver OBJECT IDENTIFIER ::= {radBridgeIPX 1 } radBridgeIPXRip OBJECT IDENTIFIER ::= {radBridgeIPX 2 } radBridgeIPXSap OBJECT IDENTIFIER ::= {radBridgeIPX 3 } radBridgeIPXForwarding OBJECT-TYPE SYNTAX INTEGER { forwarding(1), not-forwarding(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The indication of whether this entity is acting as an IPX gateway in respect to the forwarding of datagrams received by, but not addressed to, this entity. IPX gateways forward datagrams. IPX hosts do not. Note that changing this parameter requiers RESET of the router." -- DEFVAL { 1 } ::= { radBridgeIPXdriver 1 } radBridgeIPXRipOutPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets transmitted by RIP." ::= { radBridgeIPXRip 1 } radBridgeIPXRipInPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received by RIP. This will include any packets that are subsequently discarded." ::= { radBridgeIPXRip 2 } radBridgeIPXRipInDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received packets discarded by RIP." ::= { radBridgeIPXRip 3 } radBridgeIPXRipTblNoOfEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The max number of entries that exist in the RIP routing table." ::= { radBridgeIPXRip 4 } radBridgeIPXRipTblBcastTrigUpdateInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The default time interval (in seconds)between triggered RIP updates on a broadcast type interface. A triggered update occurs when a change is detected in the routing database. This time interval delays the broadcasting of these updates so that changes on the network will not result in a lot of triggered updates." ::= { radBridgeIPXRip 5 } radBridgeIPXRipTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeIPXRipTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The routing table used by RIP to calculate routes to remote desination networks." ::= { radBridgeIPXRip 6 } radBridgeIPXRipTableEntry OBJECT-TYPE SYNTAX RadBridgeIPXRipTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The routing information for one of this entity's destination networks." INDEX { radBridgeIPXRipDestNetwork, radBridgeIPXRipPolicy } ::= { radBridgeIPXRipTable 1 } RadBridgeIPXRipTableEntry ::= SEQUENCE { radBridgeIPXRipDestNetwork OCTET STRING (SIZE(4)), radBridgeIPXRipPolicy INTEGER, radBridgeIPXRipForwardingRouter OCTET STRING (SIZE(6)), radBridgeIPXRipNIC Integer32, radBridgeIPXRipTickMetric Integer32, radBridgeIPXRipHopMetric Integer32, radBridgeIPXRipAgingTime TimeTicks, radBridgeIPXRipValueStatus INTEGER, radBridgeIPXRipForwardType INTEGER } radBridgeIPXRipDestNetwork OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The destination network address to which this entry's routing information pertains." ::= {radBridgeIPXRipTableEntry 1 } radBridgeIPXRipPolicy OBJECT-TYPE SYNTAX INTEGER { main(1), alternate(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "A value specifying the precidence of the route. A value of zero means that the route is the best route, a value of one means that the route is the second best route and so on." ::= { radBridgeIPXRipTableEntry 2 } radBridgeIPXRipForwardingRouter OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-write STATUS current DESCRIPTION "The IPX node address of the next hop (router) for the entry's associated destination network." ::= { radBridgeIPXRipTableEntry 3 } radBridgeIPXRipNIC OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "An interface identifier specifying what IPX interface the next hop can be found on." ::= { radBridgeIPXRipTableEntry 4 } radBridgeIPXRipTickMetric OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The metric, in terms of transit time, associated with the route given by the entry. This time is in terms of 1/18ths of a second." ::= { radBridgeIPXRipTableEntry 5 } radBridgeIPXRipHopMetric OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The metric, in terms of distance , associated with the route given by the entry." ::= { radBridgeIPXRipTableEntry 6 } radBridgeIPXRipAgingTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The last time that the entry was updated. The time will be provided in terms of the MIB-I object sysUpTime." ::= {radBridgeIPXRipTableEntry 7 } radBridgeIPXRipValueStatus OBJECT-TYPE SYNTAX INTEGER { static(1), dynamic(2), invalid(3), semiDynamic(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The entry status value; whether the entry is permanent (added statically), reachable or unreachable. In the latter two cases it would be added by RIP. A semiDynamic entry is an entry enterd manualy by the user and can be updated by the router." ::= { radBridgeIPXRipTableEntry 8 } radBridgeIPXRipForwardType OBJECT-TYPE SYNTAX INTEGER { other (1), -- not specified by this MIB local (2), -- local interface remote (3) -- remote destination } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of route. Note that local(2) refers to a route for which the next hop is the final destination; remote(3) refers to a route for which the next hop is not the final destination." ::= {radBridgeIPXRipTableEntry 9 } radBridgeIPXRipInfTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeIPXRipInfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RIP interface table." ::= { radBridgeIPXRip 7 } radBridgeIPXRipInfEntry OBJECT-TYPE SYNTAX RadBridgeIPXRipInfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry corresponds to one ifindex." INDEX { radBridgeIPXRipInfIfIndex} ::= { radBridgeIPXRipInfTable 1 } RadBridgeIPXRipInfEntry ::= SEQUENCE { radBridgeIPXRipInfIfIndex Integer32, radBridgeIPXRipInfBcastUpdate Integer32, radBridgeIPXRipInfAgeMultiplier Integer32 } radBridgeIPXRipInfIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value of Ifindex is same as radBridgeIPXIfIndex in the IPX Interface Table." ::= { radBridgeIPXRipInfEntry 1 } radBridgeIPXRipInfBcastUpdate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The RIP periodic update interval, in seconds. Zero value corresponds to infinite interval." -- DEFVAL {60} ::= { radBridgeIPXRipInfEntry 2 } radBridgeIPXRipInfAgeMultiplier OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The holding multiplier for information received in RIP periodic updates. Zero value corresponds to infinite aging time." -- DEFVAL {3} ::= { radBridgeIPXRipInfEntry 3 } radBridgeIPXSapOutPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets transmitted by SAP." ::= { radBridgeIPXSap 1 } radBridgeIPXSapInPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received by SAP. This will include any packets that are subsequently discarded." ::= { radBridgeIPXSap 2 } radBridgeIPXSapInDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received packets discarded by SAP." ::= { radBridgeIPXSap 3 } radBridgeIPXSapTblNoOfEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The max number of entries that exist in the SAP Server Information table." ::= { radBridgeIPXSap 4 } radBridgeIPXSapTblBcastTrigUpdateInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The default time interval (in seconds) between triggered SAP updates on a broadcast style interface. A triggered update occurs when a change is detected in the service database. This time interval delays the transmission of these updates so that changes on the network will not result in a lot of triggered updates." ::= { radBridgeIPXSap 5 } radBridgeIPXSapTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeIPXSapTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Server Information table is used by SAP to store information of services which are available on the internetwork." ::= { radBridgeIPXSap 6 } radBridgeIPXSapTableEntry OBJECT-TYPE SYNTAX RadBridgeIPXSapTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The server information for one of this entity's server entries." INDEX { radBridgeIPXSapServerType, radBridgeIPXSapName } ::= { radBridgeIPXSapTable 1 } RadBridgeIPXSapTableEntry ::= SEQUENCE { radBridgeIPXSapServerType Integer32, radBridgeIPXSapName DisplayString (SIZE(48)), radBridgeIPXSapNetwork OCTET STRING (SIZE(4)), radBridgeIPXSapNode OCTET STRING (SIZE(6)), radBridgeIPXSapSocket Integer32, radBridgeIPXSapHopsToServer Integer32, radBridgeIPXSapNIC Integer32, radBridgeIPXSapAgingTime TimeTicks, radBridgeIPXSapStatus INTEGER } radBridgeIPXSapServerType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the server for which this entry pertains." ::= { radBridgeIPXSapTableEntry 1 } radBridgeIPXSapName OBJECT-TYPE SYNTAX DisplayString (SIZE(48)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the server for which this entry pertains." ::= { radBridgeIPXSapTableEntry 2 } radBridgeIPXSapNetwork OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-write STATUS current DESCRIPTION "The IPX network address of the host on which this server exists." ::= { radBridgeIPXSapTableEntry 3 } radBridgeIPXSapNode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-write STATUS current DESCRIPTION "The IPX node address of the host on which this server exists." ::= { radBridgeIPXSapTableEntry 4 } radBridgeIPXSapSocket OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The IPX socket number that is being used by the server to which this entry pertains." ::= { radBridgeIPXSapTableEntry 5 } radBridgeIPXSapHopsToServer OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of hops to the entity on which this server exists." ::= { radBridgeIPXSapTableEntry 6 } radBridgeIPXSapNIC OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "An Network Interface Card identifier specifying what IPX interface the next hop can be found on." ::= { radBridgeIPXSapTableEntry 7 } radBridgeIPXSapAgingTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The last time that the entry was updated. The time will be provided in terms of the MIB-I object sysUpTime." ::= { radBridgeIPXSapTableEntry 8 } radBridgeIPXSapStatus OBJECT-TYPE SYNTAX INTEGER { permanent(1), dynamic(2), invalid(3), semiDynamic(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of the entry." ::= { radBridgeIPXSapTableEntry 9 } radBridgeIPXSapInfTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeIPXSapInfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Sap interface table." ::= { radBridgeIPXSap 7 } radBridgeIPXSapInfEntry OBJECT-TYPE SYNTAX RadBridgeIPXSapInfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry corresponds to one ifindex." INDEX {radBridgeIPXSapInfIfIndex} ::= { radBridgeIPXSapInfTable 1 } RadBridgeIPXSapInfEntry ::= SEQUENCE { radBridgeIPXSapInfIfIndex Integer32, radBridgeIPXSapInfBcastUpdate Integer32, radBridgeIPXSapInfAgeMultiplier Integer32 } radBridgeIPXSapInfIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value of Ifindex is same as radBridgeIPXIfIndex in the IPX Interface Table." ::= { radBridgeIPXSapInfEntry 1 } radBridgeIPXSapInfBcastUpdate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The SAP periodic update interval, in seconds. Zero value corresponds to infinite interval." -- DEFVAL {60} ::= { radBridgeIPXSapInfEntry 2 } radBridgeIPXSapInfAgeMultiplier OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The holding multiplier for information received in SAP periodic updates. Zero value corresponds to infinite aging time." -- DEFVAL {3} ::= { radBridgeIPXSapInfEntry 3 } -- radMaskingTab defines the new format of RAD Bridge masking tables GenAddress ::= OCTET STRING (SIZE(12)) newMasking OBJECT IDENTIFIER ::= {genBridge 6 } maskingMaxEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of entries in the masking table." ::= { newMasking 1 } maskingCurrentEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of entries in the mask table." ::= { newMasking 2 } maskingTable OBJECT-TYPE SYNTAX SEQUENCE OF MaskingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the new masking scheme. Mask tables enable definition of forwarding restrictions and control of message flow in the internetwork. Each entry in this table defines a mask statement and an action defined by maskingOperation." ::= { newMasking 3 } maskingEntry OBJECT-TYPE SYNTAX MaskingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the mask table." INDEX { maskingType, maskingIfIndex, maskingIndex } ::= { maskingTable 1 } MaskingEntry ::= SEQUENCE { maskingType INTEGER, maskingIfIndex Integer32, maskingIndex Integer32, maskingProtocolType INTEGER, maskingSmartMaskOID OBJECT IDENTIFIER, maskingFrameType INTEGER, maskingFrameTypeCondition INTEGER, maskingSourceAddress GenAddress, maskingSourceActiveBits GenAddress, maskingSourceMacOrNet INTEGER, maskingSourceCondition INTEGER, maskingDestAddress GenAddress, maskingDestActiveBits GenAddress, maskingDestMacOrNet INTEGER, maskingDestCondition INTEGER, maskingLowLevelProt INTEGER, maskingLowLevelProtCondition INTEGER, maskingHighLevelProt Integer32, maskingHighLevelProtCondition INTEGER, maskingPortNum Integer32, maskingPortNumCondition INTEGER, maskingOperation INTEGER, maskingSrcPortNum Integer32, maskingSrcPortNumCondition INTEGER } maskingType OBJECT-TYPE SYNTAX INTEGER { tx (1), rx (2), compress(3), priority(4), loadSharing(5), facs(6), codConnect(7), codDisconnect(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the type of mask entry. " ::= { maskingEntry 1 } maskingIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the ifIndex of the interface to which the mask is applied." ::= { maskingEntry 2 } maskingIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "An index to the masking table. This number should not be greater than maskingMaxEntries" ::= { maskingEntry 3 } maskingProtocolType OBJECT-TYPE SYNTAX INTEGER { unknown (1), ip (2), ipx (3), sna (4), netbios (5), apple (6), dec (7), all (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The base protocol for masking. IPX, IP, others." ::= { maskingEntry 4 } maskingSmartMaskOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "A reference to a specific Smart mask table (old radBridgeMaskTable) which enables a more specific mask type. If this information is not available, its value should be set to the OBJECT IDENTIFIER { 0 0 }. " ::= { maskingEntry 5 } maskingFrameType OBJECT-TYPE SYNTAX INTEGER { unknown (1), all (2), broadcast (3), multicast (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables the user to decide about frame type * all frame * just broadcast * just multicast." ::= { maskingEntry 6 } maskingFrameTypeCondition OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingFrameType the packet contains data that matches the content of maskingFrameType. fa lse - Condition is valid if at the position specified by maskingFrameType the packet contains data that does not match the content of maskingFrameType." ::= { maskingEntry 7 } maskingSourceAddress OBJECT-TYPE SYNTAX GenAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The source address is according to the maskingMacOrNet and maskingProtocolType variables. In case of 'MAC' enter 6 bytes (48 bit) of source address. In case of 'NET' if the maskingProtocolType is IP, this is the IP address if the maskingProtocolType is IPX, this is the IPX address (nnnnmmmmmmss) nnnn - IPX net address mmmmmm - Node address (Mac) ss - IPX socket In case of 'Apple' nn - net address (4 nibbles) ss - socket (4 nibbles)." ::= { maskingEntry 8 } maskingSourceActiveBits OBJECT-TYPE SYNTAX GenAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the positions of the wild card characters (*) in the maskingSourceAddress field. Only the 1's bit will be taken in considerations." ::= { maskingEntry 9 } maskingSourceMacOrNet OBJECT-TYPE SYNTAX INTEGER { macAddress (1), netAddress (2), ipRange (3), appleAddress(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The variable maskingSourceAddress and maskingSourceActiveBits will be treated as MAC, or NET address. - If maskingProtocolType = 'all', 'sna', 'netbios', dec or 'unknown', the maskingSourceMacOrNet can be macAddress only! - If maskingProtocolType = 'ip' the maskingSourceMacOrNet can be macAddress or netAddress or appleAddress. - If maskingProtocolType = 'ipx', the maskingSourceMacOrNet can be either macAddress or netAddress. - If maskingProtocolType = 'apple', the maskingSourceMacOrNet can be either macAddress or appleAddress." ::= { maskingEntry 10 } maskingSourceCondition OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingSourceAddress (in conjunction with maskingSourceActiveBits) the packet contains data that matches the content of maskingSourceAddress. false - Condition is valid if at the position specified by maskingSourceAddress (in conjunction with maskingSourceActiveBits) the packet contains data that does not match the content of maskingSourceAddress." ::= { maskingEntry 11 } maskingDestAddress OBJECT-TYPE SYNTAX GenAddress MAX-ACCESS read-write STATUS current DESCRIPTION "If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. The destination address is according to the maskingMacOrNet and maskingProtocolType variables. In case of 'MAC' enter 6 bytes (48 bit) of source address. In case of 'NET' if the maskingProtocolType is IP, this is the IP address if the maskingProtocolType is IPX, this is the IPX address (nnnnmmmmmmss) nnnn - IPX net address mmmmmm - Node address (Mac) ss - IPX socket. In case of 'Apple' nn - net address (4 nibbles) ss - socket (4 nibbles). The IPX socket entered here has priority over the value of maskingLowLevelProt, when it is ipxRip, ipxSap or ipxSpx, unless the entered IPX socket is don't care. " ::= { maskingEntry 12 } maskingDestActiveBits OBJECT-TYPE SYNTAX GenAddress MAX-ACCESS read-write STATUS current DESCRIPTION "If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. Specifies the positions of the wild card characters (*) in the maskingDestAddress field. Only the 1's bit will be taken in considerations." ::= { maskingEntry 13 } maskingDestMacOrNet OBJECT-TYPE SYNTAX INTEGER { macAddress (1), netAddress (2), ipRange (3), appleAddress(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. - If maskingProtocolType = 'all', 'sna', 'netbios', dec or 'unknown', the maskingDestMacOrNet can be macAddress only! - If maskingProtocolType = 'ip' the maskingDestMacOrNet can be macAddress or netAddress or appleAddress. - If maskingProtocolType = 'ipx', the maskingDestMacOrNet can be either macAddress or netAddress. - If maskingProtocolType = 'apple', the maskingDestMacOrNet can be either macAddress or appleAddress. The variable maskingDestAddress and maskingDestActiveBits will be treated as MAC, or NET address. " ::= { maskingEntry 14 } maskingDestCondition OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingDestAddress (in conjunction with maskingDestActiveBits) the packet contains data that matches the content of maskingDestAddress. false - Condition is valid if at the position specified by maskingDestAddress (in conjunction with maskingDestActiveBits) the packet contains data that does not match the content of maskingDestAddress." ::= { maskingEntry 15 } maskingLowLevelProt OBJECT-TYPE SYNTAX INTEGER { unknown (1), -- don't care ipxRip (2), -- 0x51 ipxSap (3), -- 0x52 ipxSpx (4), -- 0x53 ipUdp (5), -- 0x54 ipTcp (6), -- 0x55 ipIcmp (7), -- 0x56 ipxNcp (8), -- 0x57 ipxWan (9), -- 0x58 ipxEco (10), -- 0x59 ipxErr (11), -- 0x5a ipxPep (12) -- 0x5b } MAX-ACCESS read-write STATUS current DESCRIPTION "This field is set in conjunction with the maskingProtocolType variable. This variable specifies the low level protocol. The IPX socket entered in maskingDestAddress has priority over the value of maskingLowLevelProt, when it is ipxRip, ipxSap or ipxSpx, unless the entered IPX socket is don't care." ::= { maskingEntry 16 } maskingLowLevelProtCondition OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingLowLevelProt the packet contains data that matches the content of maskingLowLevelProt. false - Condition is valid if at the position specified by maskingLowLevelProt the packet contains data that does not match the content of maskingLowLevelProt." ::= { maskingEntry 17 } maskingHighLevelProt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This field is set in connection to the maskingProtocolType variable. This variable specifies the high level protocols (application). As for today it supports just IP protocol stack. The object's value is a sum of the following instances values (selected by user): none (0), -- don't care ftp (1), ftpC (2), telnet (4), smtp (8), tftp (16), snmp (32), snmpTrap (64), ipRip (128), www (256), email (512), dns (1024), For Apple Protocol only: rtmp (2048), nbp (4096), atp (8192), aep (16384), zip (32768), adsp (65536), pap (131072), asp (262144) Example: if ftp(1), snmp(32) and snmpTrap(64) instances were selected, the value should be 97 (=1+32+64)." ::= { maskingEntry 18 } maskingHighLevelProtCondition OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingHighLevelProt the packet contains data that matches the content of maskingHighLevelProt. false - Condition is valid if at the position specified by maskingHighLevelProt the packet contains data that does not match the content of maskingHighLevelProt." ::= { maskingEntry 19 } maskingPortNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The port number is the same as in high level protocol. It specifies the dest. port in IP case or the dest. socket in case of IPX & apple protocols. IP - This object is applicable only if none (0) value was selected in maskingHighLevelProt. IPX - This object is applicable only if the socket entered in maskingDestAddress is 'don't care'(00) AND maskingLowLevelProt is NOT ipxRip or ipxSap. Apple - This option is applicable only if the socket entered in maskingDestAddress is 'don't care'(00)." ::= { maskingEntry 20 } maskingPortNumCondition OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingPortNum the packet contains data that matches the content of maskingPortNum. false - Condition is valid if at the position specified by maskingPortNum the packet contains data that does not match the content of maskingPortNum. This object is applicable only when maskingPortNum is applicable." ::= { maskingEntry 21 } maskingOperation OBJECT-TYPE SYNTAX INTEGER { block (1), forward (2), route (3), forward-route (4), high-priority (5), noOp (6), delete (7), smartMask (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of action to be taken if the frame meets the conditions of the mask. noOp = disabled (mask remains on list, but is not active) delete = mask is removed from the list. smartMask = the operation and destination of the mask will be determined by the objects of the Smart Table (old masking table: radBridgeMaskTable). If maskingType is codConnect, the 'block' value is NOT allowed. If maskingType is codDisconnect, the 'forward' value is NOT allowed." ::= { maskingEntry 22 } maskingSrcPortNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The source port number. For IP: No Condition. For IPX: This object is applicable only if the socket entered in maskingSourceAddress is don't care (00) and maskingLowLevelProt is NOT ipxRip or ipxSap. For Apple:This object is applicable only if the socket entered in maskingSourceAddress is don't care (00). " ::= { maskingEntry 23 } maskingSrcPortNumCondition OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The same as 'maskingPortNumCondition'. Relates to source port." ::= { maskingEntry 24 } radBridgePerformance OBJECT IDENTIFIER ::= {genBridge 7 } -- The RAD Bridge current table contains statistics being -- collected for the current 15 minute interval. radBridgeCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RAD Bridge Current table." ::= { radBridgePerformance 1 } radBridgeCurrentEntry OBJECT-TYPE SYNTAX RadBridgeCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the RAD Bridge Current table." INDEX { radBridgeCurrentIndex } ::= { radBridgeCurrentTable 1 } RadBridgeCurrentEntry ::= SEQUENCE { radBridgeCurrentIndex Integer32, radBridgeCurrentIngressFilteringDiscardedFrames Gauge32, radBridgeCurrentFrameTypeDiscardedFrames Gauge32 } radBridgeCurrentIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Bridge interface. It may be ifIndex." ::= { radBridgeCurrentEntry 1 } radBridgeCurrentIngressFilteringDiscardedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded Frames upon Ingress Filtering, encountered by a Bridge interface in the current 15 minute interval." ::= { radBridgeCurrentEntry 2 } radBridgeCurrentFrameTypeDiscardedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded Frames upon Frame Type and Tagging Mismatch, encountered by a Bridge interface in the current 15 minute interval." ::= { radBridgeCurrentEntry 3 } --Interval Table -- The RAD Bridge Interval table contains statistics being -- collected by each Interface over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. radBridgeIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RAD Bridge Interval table." ::= { radBridgePerformance 2 } radBridgeIntervalEntry OBJECT-TYPE SYNTAX RadBridgeIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the RAD Bridge Interval table." INDEX { radBridgeIntervalIndex, radBridgeIntervalNumber } ::= { radBridgeIntervalTable 1 } RadBridgeIntervalEntry ::= SEQUENCE { radBridgeIntervalIndex Integer32, radBridgeIntervalNumber Integer32, radBridgeIntervalIngressFilteringDiscardedFrames Gauge32, radBridgeIntervalFrameTypeDiscardedFrames Gauge32 } radBridgeIntervalIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the bridge interface. It may be ifIndex." ::= { radBridgeIntervalEntry 1 } radBridgeIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist)." ::= { radBridgeIntervalEntry 2 } radBridgeIntervalIngressFilteringDiscardedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded Frames upon Ingress Filtering, encountered by a Bridge interface in one of the previous 96, individual 15 minute, intervals." ::= { radBridgeIntervalEntry 3 } radBridgeIntervalFrameTypeDiscardedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded Frames upon Frame Type and Tagging Mismatch, encountered by a Bridge interface in one of the previous 96, individual 15 minute, intervals." ::= { radBridgeIntervalEntry 4 } radBridgePortBaseVlan OBJECT IDENTIFIER ::= {genBridge 8 } radBridgePortBaseVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgePortBaseVlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing static configuration information for each VLAN configured into the device by management. All entries are permanent and will be restored after the device is reset." ::= { radBridgePortBaseVlan 1 } radBridgePortBaseVlanEntry OBJECT-TYPE SYNTAX RadBridgePortBaseVlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Static information for a VLAN configured into the device by (local or network) management." INDEX { radBridgePortBaseVlanCnfgIdx,radBridgePortBaseVlanIdx } ::= { radBridgePortBaseVlanTable 1 } RadBridgePortBaseVlanEntry ::= SEQUENCE { radBridgePortBaseVlanCnfgIdx Integer32, radBridgePortBaseVlanIdx Integer32, radBridgePortBaseVlanName SnmpAdminString, radBridgePortBaseVlanEgressPorts PortList, radBridgePortBaseVlanVirtualGroups PortList, radBridgePortBaseVlanRowStatus RowStatus, radBridgePortBaseVlanMng INTEGER } radBridgePortBaseVlanCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg (when relevant, Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1. " ::= { radBridgePortBaseVlanEntry 1 } radBridgePortBaseVlanIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the port based VLAN." ::= { radBridgePortBaseVlanEntry 2 } radBridgePortBaseVlanName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "An administratively assigned string, which may be used to identify the the port based VLAN." ::= { radBridgePortBaseVlanEntry 3 } radBridgePortBaseVlanEgressPorts OBJECT-TYPE SYNTAX PortList MAX-ACCESS read-create STATUS current DESCRIPTION "The set of ports which are permanently assigned to the egress list for this port based VLAN by management. The default value of this object is a string of zeros." ::= { radBridgePortBaseVlanEntry 4 } radBridgePortBaseVlanVirtualGroups OBJECT-TYPE SYNTAX PortList MAX-ACCESS read-create STATUS current DESCRIPTION "The set of Virtual Groups which are permanently assigned to this port based VLAN by management. (read Virtual Group instead of port in PortList Textual Convention) The default value of this object is a string of zeros." ::= { radBridgePortBaseVlanEntry 5 } radBridgePortBaseVlanRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object enable user to create/delete entries in this table." ::= { radBridgePortBaseVlanEntry 6 } radBridgePortBaseVlanMng OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object allows user to enable/disable management traffic on this VLAN." ::= { radBridgePortBaseVlanEntry 7 } -- The Bridge's Ports-VLANs Memebership Table radBridgePortVlanMemberTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgePortVlanMemberEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Bridge Ports-VLAN Membership table. This table enables the user to assign: - Several VLANs to a Port. - Several Ports to a VLAN." ::= { radBridgePortBaseVlan 2 } radBridgePortVlanMemberEntry OBJECT-TYPE SYNTAX RadBridgePortVlanMemberEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Bridge Ports-VLANs Memebership table." INDEX { radBridgePortVlanMemberBridgeIdx, radBridgePortVlanMemberPortIdx, radBridgePortVlanMemberVlanId } ::= { radBridgePortVlanMemberTable 1 } RadBridgePortVlanMemberEntry ::= SEQUENCE { radBridgePortVlanMemberBridgeIdx Integer32, radBridgePortVlanMemberPortIdx Integer32, radBridgePortVlanMemberVlanId Integer32, radBridgePortVlanMemberRowStatus RowStatus } radBridgePortVlanMemberBridgeIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Bridge Index." ::= { radBridgePortVlanMemberEntry 1 } radBridgePortVlanMemberPortIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Bridge's Port Index. For some cases, it can be used as the Port ofIndex." ::= { radBridgePortVlanMemberEntry 2 } radBridgePortVlanMemberVlanId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the VLAN ID." ::= { radBridgePortVlanMemberEntry 3 } radBridgePortVlanMemberRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables the user to create/delete entries in this table." ::= { radBridgePortVlanMemberEntry 4 } radBridgeGenCnfg OBJECT IDENTIFIER ::= {genBridge 9 } radBridgeGenFlowTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeGenFlowEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing static configuration information for Bridge configured into the device by (local or network) management. All entries are permanent and will be restored after the device is reset." ::= { radBridgeGenCnfg 1 } radBridgeGenFlowEntry OBJECT-TYPE SYNTAX RadBridgeGenFlowEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Static information for a Bridge configured into the device by management." INDEX { radBridgeGenFlowCnfgIdx,radBridgeGenFlowIdx } ::= { radBridgeGenFlowTable 1 } RadBridgeGenFlowEntry ::= SEQUENCE { radBridgeGenFlowCnfgIdx Integer32, radBridgeGenFlowIdx Integer32, radBridgeGenFlowRowStatus RowStatus, radBridgeGenFlowFloodOrBcastMaxRate Integer32, radBridgeGenFlowQosMode INTEGER, radBridgeGenFlowSchedulingMode INTEGER } radBridgeGenFlowCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg (when relevant, Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1. " ::= { radBridgeGenFlowEntry 1 } radBridgeGenFlowIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "For Agent having more than one bridge, this index may be used as bridge index " ::= { radBridgeGenFlowEntry 2 } radBridgeGenFlowRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object enable user to create/delete entries in this table." ::= { radBridgeGenFlowEntry 3 } radBridgeGenFlowFloodOrBcastMaxRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object controls maximum Flooding or Broadcast Rate: Max number of multicast along with unknown or flooded unicast frames allowed to enter any port. The number is presented as percentage of bandwidth. Once the limit is exceeded, any multicast or flooded frame entering from the port is discarded For RIC-155 valid values are 0-100 For FCD-155 valid values are 3% , 6%, 12% and 100% = No Limit " ::= { radBridgeGenFlowEntry 4 } radBridgeGenFlowQosMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), vlanTag (2), dscp (3), dscpAndVlanTag (4), vlanTagAndDscp (5), none (6) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object controls Quality of Service mode. User may select which field(s) (in case of fields - which one has precedence) will affect prioritization of data between egress queues." ::= { radBridgeGenFlowEntry 5 } radBridgeGenFlowSchedulingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), wfq (2), -- Weighted Fair Queuing sp (3) -- Strict Priority } MAX-ACCESS read-create STATUS current DESCRIPTION "This object controls which scheduling mode is used: Weighted Fair Queuing (WFQ) scheme or Strict Priority (SP)." ::= { radBridgeGenFlowEntry 6 } radBridgeStatus OBJECT IDENTIFIER ::= {genBridge 10 } radBridgeInvBasePortTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeInvBasePortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An inversed table to dot1dBasePortTable from RFC1493 with reduced information. This table index is known to the NMS and this way the needed information can be received by just one Get command, instead of searching the entire dot1dBasePortTable (where it is an attribute). " ::= { radBridgeStatus 1 } radBridgeInvBasePortEntry OBJECT-TYPE SYNTAX RadBridgeInvBasePortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The bridge port number for each bridge port interface index." INDEX { radBridgeInvBasePortIfIndex } ::= { radBridgeInvBasePortTable 1 } RadBridgeInvBasePortEntry ::= SEQUENCE { radBridgeInvBasePortIfIndex Integer32, radBridgeInvBasePort Integer32 } radBridgeInvBasePortIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the instance of the ifIndex object, defined in MIB-II, for the interface corresponding to this Bridge port." ::= { radBridgeInvBasePortEntry 1 } radBridgeInvBasePort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Bridge port number." ::= { radBridgeInvBasePortEntry 2 } -- END -- -- file :v:\doc\rdv\mib\ver495\radsonet.txt -- -- RAD-SONET-MIB DEFINITIONS ::= BEGIN --Title: RAD-SONET MIB ver495 -- -- IMPORTS -- Gauge32 FROM RFC1155-SMI -- ifIndex FROM RFC1213-MIB -- OBJECT-TYPE FROM RFC-1212 -- radWan FROM RAD-GEN-MIB; -- RAD-SONET MIB --Title: RAD's SONET INTERFACE MIB --Version: 1.0 --Date: 13.10.96 --By: Yair Arian --File: sonet.mib -- --Last update: 25-Septemper-2002 by Yig'al Hachmon sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2} prtSonetPerfHistory OBJECT IDENTIFIER ::= {sonetInterface 1} -- The SONET Medium Table prtSonetMediumTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSonetMediumEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SONET Medium table." ::= { prtSonetPerfHistory 1 } prtSonetMediumEntry OBJECT-TYPE SYNTAX PrtSonetMediumEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET Medium table. ifIndex of the lowest SONET layer of type sonet(39)." INDEX { ifIndex } ::= { prtSonetMediumTable 1 } PrtSonetMediumEntry ::= SEQUENCE { prtSonetMediumTimeElapsed Integer32, prtSonetMediumValidIntervals Integer32 } prtSonetMediumTimeElapsed OBJECT-TYPE SYNTAX Integer32 (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the near end current error- measurement period." ::= { prtSonetMediumEntry 1 } prtSonetMediumValidIntervals OBJECT-TYPE SYNTAX Integer32 (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online." ::= { prtSonetMediumEntry 2 } -- The SONET Section/Line Current Table -- The SONET Section/Line Current table contains various statistics being -- collected for the current 15 minute interval. prtSonetSectionLineCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSectionLineCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SONET Section/Line Current table." ::= { prtSonetPerfHistory 2 } prtSectionLineCurrentEntry OBJECT-TYPE SYNTAX PrtSectionLineCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET Section/Line Current table. ifIndex of the section/line SONET layer of type sonet(39)." INDEX { ifIndex } ::= { prtSonetSectionLineCurrentTable 1 } PrtSectionLineCurrentEntry ::= SEQUENCE { prtSonetCurrentLOS Gauge32, prtSonetCurrentLOF Gauge32, prtSonetCurrentLineAIS Gauge32, prtSonetCurrentLineFERF Gauge32, prtSonetCurrentSectionBIP Gauge32, prtSonetCurrentLineBIP Gauge32, prtSonetCurrentLineFEBE Gauge32, prtSonetCurrentUAS Gauge32, prtSonetCurrentSES Gauge32, prtSonetCurrentES Gauge32, prtSonetCurrentStatus OCTET STRING, prtSonetCurrentLSV Gauge32 } prtSonetCurrentLOS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOS seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 1 } prtSonetCurrentLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOF seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 2 } prtSonetCurrentLineAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line AIS seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 3 } prtSonetCurrentLineFERF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line FERF seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 4 } prtSonetCurrentSectionBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Section BIP errors, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 5 } prtSonetCurrentLineBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line BIP errors, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 6 } prtSonetCurrentLineFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line FEBE errors, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 7 } prtSonetCurrentUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of UAS encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 8 } prtSonetCurrentSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SES encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 9 } prtSonetCurrentES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 10 } prtSonetCurrentStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out." ::= { prtSectionLineCurrentEntry 11 } prtSonetCurrentLSV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LSV seconds (Line Symbol Violation), encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 12 } -- The SONET Section/Line interface Interval -- The SONET Section/Line Interval Table contains various statistics -- collected by the Interface over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. prtSonetSectionLineIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSectionLineIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Section/Line Interval table." ::= { prtSonetPerfHistory 3 } prtSectionLineIntervalEntry OBJECT-TYPE SYNTAX PrtSectionLineIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET Section/Line Interval table. ifIndex of the section/line SONET layer of type sonet(39)." INDEX { ifIndex, prtSonetLineIntervalNumber } ::= { prtSonetSectionLineIntervalTable 1 } PrtSectionLineIntervalEntry ::= SEQUENCE { prtSonetLineIntervalNumber Integer32, prtSonetIntervalLOS Gauge32, prtSonetIntervalLOF Gauge32, prtSonetIntervalLineAIS Gauge32, prtSonetIntervalLineFERF Gauge32, prtSonetIntervalSectionBIP Gauge32, prtSonetIntervalLineBIP Gauge32, prtSonetIntervalLineFEBE Gauge32, prtSonetIntervalUAS Gauge32, prtSonetIntervalSES Gauge32, prtSonetIntervalES Gauge32, prtSonetIntervalStatus OCTET STRING, prtSonetIntervalLSV Gauge32 } prtSonetLineIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { prtSectionLineIntervalEntry 1 } prtSonetIntervalLOS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOS seconds , encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 2 } prtSonetIntervalLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOF seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 3 } prtSonetIntervalLineAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line AIS seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 4 } prtSonetIntervalLineFERF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line FERF seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 5 } prtSonetIntervalSectionBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Section BIP errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 6 } prtSonetIntervalLineBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line BIP errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 7 } prtSonetIntervalLineFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line FEBE errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 8 } prtSonetIntervalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of UAS encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 9 } prtSonetIntervalSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SES encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 10 } prtSonetIntervalES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 11 } prtSonetIntervalStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION " The statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out." ::= { prtSectionLineIntervalEntry 12 } prtSonetIntervalLSV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LSV seconds (Line Symbol Violation), encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 13 } -- The SONET Path Current Table -- The SONET Path Current table contains various statistics being -- collected for the current 15 minute interval. prtSonetPathCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtPathCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SONET Path Current table." ::= { prtSonetPerfHistory 4 } prtPathCurrentEntry OBJECT-TYPE SYNTAX PrtPathCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET Path Current table. ifIndex of the Path SONET layer of type sonetPath(50)." INDEX { ifIndex } ::= { prtSonetPathCurrentTable 1 } PrtPathCurrentEntry ::= SEQUENCE { prtSonetCurrentPathAIS Gauge32, prtSonetCurrentPathFERF Gauge32, prtSonetCurrentLOP Gauge32, prtSonetCurrentSLM Gauge32, prtSonetCurrentLOC Gauge32, prtSonetCurrentPathBIP Gauge32, prtSonetCurrentPathFEBE Gauge32 } prtSonetCurrentPathAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path AIS seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtPathCurrentEntry 1 } prtSonetCurrentPathFERF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path FERF seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtPathCurrentEntry 2 } prtSonetCurrentLOP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number LOP seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtPathCurrentEntry 3 } prtSonetCurrentSLM OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SLM seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtPathCurrentEntry 4 } prtSonetCurrentLOC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOC seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtPathCurrentEntry 5 } prtSonetCurrentPathBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path BIP errors, encountered by a SONET interface in the current 15 minute interval." ::= { prtPathCurrentEntry 6 } prtSonetCurrentPathFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path FEBE errors, encountered by a SONET interface in the current 15 minute interval." ::= { prtPathCurrentEntry 7 } -- The SONET Path interface Interval -- The SONET Path Interval Table contains various statistics -- collected by the Interface over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. prtSonetPathIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtPathIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Path Interval table." ::= { prtSonetPerfHistory 5 } prtPathIntervalEntry OBJECT-TYPE SYNTAX PrtPathIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET Path Interval table." INDEX { ifIndex, prtSonetPathIntervalNumber } ::= { prtSonetPathIntervalTable 1 } PrtPathIntervalEntry ::= SEQUENCE { prtSonetPathIntervalNumber Integer32, prtSonetIntervalPathAIS Gauge32, prtSonetIntervalPathFERF Gauge32, prtSonetIntervalLOP Gauge32, prtSonetIntervalSLM Gauge32, prtSonetIntervalLOC Gauge32, prtSonetIntervalPathBIP Gauge32, prtSonetIntervalPathFEBE Gauge32 } prtSonetPathIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { prtPathIntervalEntry 1 } prtSonetIntervalPathAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path AIS seconds , encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtPathIntervalEntry 2 } prtSonetIntervalPathFERF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path FERF seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtPathIntervalEntry 3 } prtSonetIntervalLOP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOP seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtPathIntervalEntry 4 } prtSonetIntervalSLM OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SLM seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtPathIntervalEntry 5 } prtSonetIntervalLOC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOC seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtPathIntervalEntry 6 } prtSonetIntervalPathBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path BIP errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtPathIntervalEntry 7 } prtSonetIntervalPathFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path FEBE errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtPathIntervalEntry 8 } virtualIfStatistics OBJECT IDENTIFIER ::= { prtSonetPerfHistory 6} -- the Virtual Interface Current Table virtualIfCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF VirtualIfCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Virtual Interface Current table." ::= { virtualIfStatistics 1 } virtualIfCurrentEntry OBJECT-TYPE SYNTAX VirtualIfCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Virtual Interface Current table." INDEX { ifIndex } ::= { virtualIfCurrentTable 1 } VirtualIfCurrentEntry ::= SEQUENCE { virtualIfCurrentMinActiveVC Integer32, virtualIfCurrentMaxActiveVC Integer32, virtualIfCurrentRxFrames Counter64, virtualIfCurrentTxFrames Counter64, virtualIfCurrentRxAbortFrames PerfCurrentCount, virtualIfCurrentTxAbortFrames PerfCurrentCount, virtualIfCurrentMinLengthViolation PerfCurrentCount, virtualIfCurrentMaxLengthViolation PerfCurrentCount, virtualIfCurrentFcsError PerfCurrentCount, virtualIfCurrentByteDestuffingViolation PerfCurrentCount, virtualIfCurrentAdressMismatch PerfCurrentCount, virtualIfCurrentControlMismatch PerfCurrentCount, virtualIfCurrentActiveVC Integer32 } virtualIfCurrentMinActiveVC OBJECT-TYPE SYNTAX Integer32 (1..63) MAX-ACCESS read-only STATUS current DESCRIPTION "This object holds the minimum number of active virtual containers (VCs) of the Virtual Concatenation Group in the current 15-minute interval." ::= { virtualIfCurrentEntry 1 } virtualIfCurrentMaxActiveVC OBJECT-TYPE SYNTAX Integer32 (1..63) MAX-ACCESS read-only STATUS current DESCRIPTION "This object holds the maximum number of active virtual containers (VCs) of the Virtual Concatenation Group in the current 15-minute interval." ::= {virtualIfCurrentEntry 2 } virtualIfCurrentRxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of frames received from STS-3/STM-1 by a Virtual Interface in the current 15-minute interval." ::= { virtualIfCurrentEntry 3} virtualIfCurrentTxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of frames transmitted to STS-3/STM-1 by a Virtual Interface in the current 15-minute interval." ::= { virtualIfCurrentEntry 4 } virtualIfCurrentRxAbortFrames OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Received Aborted frames encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfCurrentEntry 5 } virtualIfCurrentTxAbortFrames OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Transmitted Aborted frames encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfCurrentEntry 6 } virtualIfCurrentMinLengthViolation OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of Rx payload Min Length Violation frames encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfCurrentEntry 7 } virtualIfCurrentMaxLengthViolation OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of Rx payload Max Length Violation frames encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfCurrentEntry 8 } virtualIfCurrentFcsError OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter is associated with the number of Frame Check Sequence errors encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfCurrentEntry 9 } virtualIfCurrentByteDestuffingViolation OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Byte De-stuffing Violations encountered by a Virtual Interface in the current 15-minute interval." ::= {virtualIfCurrentEntry 10 } virtualIfCurrentAdressMismatch OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Adress Mismatch encountered by a Virtual Interface in the current 15-minute interval." ::= {virtualIfCurrentEntry 11 } virtualIfCurrentControlMismatch OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Control Mismatch encountered by a Virtual Interface in the current 15-minute interval." ::= {virtualIfCurrentEntry 12 } virtualIfCurrentActiveVC OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "This object holds the number of active virtual containers (VCs) of the Virtual Concatenation Group in the current 15-minute interval." ::= {virtualIfCurrentEntry 13 } -- the Virtual Interface Interval Table -- The Virtual Interface Interval Table -- contains various statistics collected over a maximum -- of the previous 24 hours of operation. -- The past 24 hours may be broken into 96 -- completed 15 minute intervals. virtualIfIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF VirtualIfIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Virtual Interface Interval table." ::= { virtualIfStatistics 2 } virtualIfIntervalEntry OBJECT-TYPE SYNTAX VirtualIfIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Virtual Interface Interval table." INDEX { ifIndex, virtualIfIntervalNumber } ::= { virtualIfIntervalTable 1 } VirtualIfIntervalEntry ::= SEQUENCE { virtualIfIntervalNumber Integer32, virtualIfIntervalMinActiveVC Integer32, virtualIfIntervalMaxActiveVC Integer32, virtualIfIntervalRxFrames Counter64, virtualIfIntervalTxFrames Counter64, virtualIfIntervalRxAbortFrames PerfIntervalCount, virtualIfIntervalTxAbortFrames PerfIntervalCount, virtualIfIntervalMinLengthViolation PerfIntervalCount, virtualIfIntervalMaxLengthViolation PerfIntervalCount, virtualIfIntervalFcsError PerfIntervalCount, virtualIfIntervalByteDestuffingViolation PerfIntervalCount, virtualIfIntervalAdressMismatch PerfIntervalCount, virtualIfIntervalControlMismatch PerfIntervalCount, virtualIfIntervalBelowMinThreshold PerfIntervalCount } virtualIfIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A number between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1." ::= { virtualIfIntervalEntry 1 } virtualIfIntervalMinActiveVC OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "This object holds the minimum number of active virtual containers (VCs) of the Virtual Concatenation Group, in a particular 15-minute interval in the past 24 hours." ::= { virtualIfIntervalEntry 2 } virtualIfIntervalMaxActiveVC OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "This object holds the maximum number of active virtual containers (VCs) of the Virtual Concatenation Group, in a particular 15-minute interval in the past 24 hours." ::= { virtualIfIntervalEntry 3 } virtualIfIntervalRxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of frames received from STS-3/STM-1 by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfIntervalEntry 4 } virtualIfIntervalTxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of frames transmitted to STS-3/STM-1 by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfIntervalEntry 5 } virtualIfIntervalRxAbortFrames OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of Received Abort frames encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= {virtualIfIntervalEntry 6 } virtualIfIntervalTxAbortFrames OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of Transmitted Abort frames encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfIntervalEntry 7 } virtualIfIntervalMinLengthViolation OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of Rx payload Min Length Violation frames encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfIntervalEntry 8 } virtualIfIntervalMaxLengthViolation OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of Rx payload Max Length Violation frames encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfIntervalEntry 9 } virtualIfIntervalFcsError OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of Frame Check Sequence errors encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfIntervalEntry 10 } virtualIfIntervalByteDestuffingViolation OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of Byte De-stuffing Violations encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfIntervalEntry 11 } virtualIfIntervalAdressMismatch OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of Address Mismatch encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfIntervalEntry 12 } virtualIfIntervalControlMismatch OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of Control mismatch encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfIntervalEntry 13 } virtualIfIntervalBelowMinThreshold OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of seconds that number of active VCs was below minimum threshold defined by vcGroupCnfgNoOfVCs, encountered by Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfIntervalEntry 14 } -- the Virtual Interface LAPS Current Table virtualIfLAPSCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF VcGroupLAPSCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Virtual Interface LAPS Current table." ::= { virtualIfStatistics 3 } virtualIfLAPSCurrentEntry OBJECT-TYPE SYNTAX VcGroupLAPSCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Virtual Interface LAPS Current table." INDEX { ifIndex } ::= { virtualIfLAPSCurrentTable 1 } VcGroupLAPSCurrentEntry ::= SEQUENCE { virtualIfLAPSCurrentSapiMismatch PerfCurrentCount } virtualIfLAPSCurrentSapiMismatch OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received SAPI field mismatch encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfLAPSCurrentEntry 1 } -- the Virtual Interface LAPS Interval Table -- The Virtual Interface LAPS Interval Table -- contains various statistics collected over a maximum -- of the previous 24 hours of operation. -- The past 24 hours may be broken into 96 -- completed 15 minute intervals. virtualIfLAPSIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF VirtualIfLAPSIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Virtual Interface LAPS table." ::= { virtualIfStatistics 4 } virtualIfLAPSIntervalEntry OBJECT-TYPE SYNTAX VirtualIfLAPSIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Virtual Interface LAPS Interval table." INDEX { ifIndex, virtualIfIntervalNumber } ::= { virtualIfLAPSIntervalTable 1 } VirtualIfLAPSIntervalEntry ::= SEQUENCE { virtualIfLAPSIntervalSapiMismatch PerfIntervalCount } virtualIfLAPSIntervalSapiMismatch OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received SAPI field mismatch encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfLAPSIntervalEntry 1 } -- the Virtual Interface LAPF Current Table virtualIfLAPFCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF VirtualIfLAPFCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Virtual Interface LAPF Current table." ::= { virtualIfStatistics 5 } virtualIfLAPFCurrentEntry OBJECT-TYPE SYNTAX VirtualIfLAPFCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Virtual Interface LAPF Current table." INDEX { ifIndex } ::= { virtualIfLAPFCurrentTable 1 } VirtualIfLAPFCurrentEntry ::= SEQUENCE { virtualIfLAPFCurrentNlpidMismatch PerfCurrentCount, virtualIfLAPFCurrentOuiMismatch PerfCurrentCount, virtualIfLAPFCurrentPidMismatch PerfCurrentCount, virtualIfLAPFCurrentDlciMismatch PerfCurrentCount, virtualIfLAPFCurrentMacRxFrames PerfCurrentCount, virtualIfLAPFCurrentMacTxFrames PerfCurrentCount } virtualIfLAPFCurrentNlpidMismatch OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received NLPID field mismatch encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfLAPFCurrentEntry 1 } virtualIfLAPFCurrentOuiMismatch OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received OUI field mismatch encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfLAPFCurrentEntry 2 } virtualIfLAPFCurrentPidMismatch OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received PID field mismatch encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfLAPFCurrentEntry 3 } virtualIfLAPFCurrentDlciMismatch OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received DLCI field mismatch encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfLAPFCurrentEntry 4 } virtualIfLAPFCurrentMacRxFrames OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of frames received from LAN by a Virtual Interface in the current 15-minute interval." ::= { virtualIfLAPFCurrentEntry 5 } virtualIfLAPFCurrentMacTxFrames OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of frames transmitted to LAN by a Virtual Interface in the current 15-minute interval." ::= { virtualIfLAPFCurrentEntry 6 } -- the Virtual Interface LAPF Interval Table -- The Virtual Interface LAPF Interval Table -- contains various statistics collected over a maximum -- of the previous 24 hours of operation. -- The past 24 hours may be broken into 96 -- completed 15 minute intervals. virtualIfLAPFIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF VirtualIfLAPFIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Virtual Interface LAPF Interval table." ::= { virtualIfStatistics 6 } virtualIfLAPFIntervalEntry OBJECT-TYPE SYNTAX VirtualIfLAPFIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Virtual Interface Interval table." INDEX { ifIndex, virtualIfIntervalNumber } ::= { virtualIfLAPFIntervalTable 1 } VirtualIfLAPFIntervalEntry ::= SEQUENCE { virtualIfLAPFIntervalNlpidMismatch PerfIntervalCount, virtualIfLAPFIntervalOuiMismatch PerfIntervalCount, virtualIfLAPFIntervalPidMismatch PerfIntervalCount, virtualIfLAPFIntervalDlciMismatch PerfIntervalCount, virtualIfLAPFIntervalMacRxFrames PerfIntervalCount, virtualIfLAPFIntervalMacTxFrames PerfIntervalCount } virtualIfLAPFIntervalNlpidMismatch OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received NLPID field mismatch encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfLAPFIntervalEntry 1 } virtualIfLAPFIntervalOuiMismatch OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received OUI field mismatch encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfLAPFIntervalEntry 2 } virtualIfLAPFIntervalPidMismatch OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received PID field mismatch encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfLAPFIntervalEntry 3 } virtualIfLAPFIntervalDlciMismatch OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received DLCI field mismatch by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfLAPFIntervalEntry 4 } virtualIfLAPFIntervalMacRxFrames OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of frames received from LAN by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfLAPFIntervalEntry 5 } virtualIfLAPFIntervalMacTxFrames OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of frames transmitted to LAN encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfLAPFIntervalEntry 6 } -- the Virtual Interface GFP Current Table virtualIfGFPCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF VirtualIfGFPCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Virtual Interface GFP Current table." ::= { virtualIfStatistics 7 } virtualIfGFPCurrentEntry OBJECT-TYPE SYNTAX VirtualIfGFPCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Virtual Interface GFP Current table." INDEX { ifIndex } ::= { virtualIfGFPCurrentTable 1 } VirtualIfGFPCurrentEntry ::= SEQUENCE { virtualIfGFPCurrentIdleFrameError PerfCurrentCount, virtualIfGFPCurrentCHecSbError PerfCurrentCount, virtualIfGFPCurrentPtiMismatch PerfCurrentCount, virtualIfGFPCurrentExiMismatch PerfCurrentCount, virtualIfGFPCurrentUpiMismatch PerfCurrentCount, virtualIfGFPCurrentTHecSbError PerfCurrentCount, virtualIfGFPCurrentTHecMbError PerfCurrentCount, virtualIfGFPCurrentCidMismatch PerfCurrentCount, virtualIfGFPCurrentEHecSbError PerfCurrentCount, virtualIfGFPCurrentEHecMbError PerfCurrentCount } virtualIfGFPCurrentIdleFrameError OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP IDLE frames that are detected to be in error, encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfGFPCurrentEntry 1} virtualIfGFPCurrentCHecSbError OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP frames that are detected to have single-bit errors in the Core header (i.e. cHEC field) only, encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfGFPCurrentEntry 2 } virtualIfGFPCurrentPtiMismatch OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of rreceived GFP frames that are detected with a mismatch on the PTI field (i.e. value of PTI is not equal to Client Data or Management frame), encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfGFPCurrentEntry 3 } virtualIfGFPCurrentExiMismatch OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP frames that are detected with a mismatch on the EXI field (i.e. value of EXI is not equal to NULL or LINEAR modes), encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfGFPCurrentEntry 4 } virtualIfGFPCurrentUpiMismatch OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP frames that are detected with a mismatch on the UPI field (i.e. value of EXI is not equal to 00000001), encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfGFPCurrentEntry 5 } virtualIfGFPCurrentTHecSbError OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP frames that are detected to only have single-bit errors in the Type header (i.e. tHEC field), encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfGFPCurrentEntry 6 } virtualIfGFPCurrentTHecMbError OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP frames that are detected to only have multi-bit errors in the Type header (i.e. tHEC field), encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfGFPCurrentEntry 7 } virtualIfGFPCurrentCidMismatch OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP frames that are detected to have a mismatch/unsupported value in the CID field only, encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfGFPCurrentEntry 8 } virtualIfGFPCurrentEHecSbError OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP frames that are detected to only have single-bit errors in the Extension header (i.e. eHEC field), encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfGFPCurrentEntry 9 } virtualIfGFPCurrentEHecMbError OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP frames that are detected to only have single-bit errors in the Extension header (i.e. eHEC field), encountered by a Virtual Interface in the current 15-minute interval." ::= { virtualIfGFPCurrentEntry 10 } -- the Virtual Interface GFP Interval Table -- The Virtual Interface GFP Interval Table -- contains various statistics collected over a maximum -- of the previous 24 hours of operation. -- The past 24 hours may be broken into 96 -- completed 15 minute intervals. virtualIfGFPIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF VirtualIfGFPIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Virtual Interface GFP Interval table." ::= { virtualIfStatistics 8 } virtualIfGFPIntervalEntry OBJECT-TYPE SYNTAX VirtualIfGFPIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Virtual Interface GFP Interval table." INDEX { ifIndex, virtualIfIntervalNumber } ::= { virtualIfGFPIntervalTable 1 } VirtualIfGFPIntervalEntry ::= SEQUENCE { virtualIfGFPIntervalIdleFrameError PerfIntervalCount, virtualIfGFPIntervalCHecSbError PerfIntervalCount, virtualIfGFPIntervalPtiMismatch PerfIntervalCount, virtualIfGFPIntervalExiMismatch PerfIntervalCount, virtualIfGFPIntervalUpiMismatch PerfIntervalCount, virtualIfGFPIntervalTHecSbError PerfIntervalCount, virtualIfGFPIntervalTHecMbError PerfIntervalCount, virtualIfGFPIntervalCidMismatch PerfIntervalCount, virtualIfGFPIntervalEHecSbError PerfIntervalCount, virtualIfGFPIntervalEHecMbError PerfIntervalCount } virtualIfGFPIntervalIdleFrameError OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP IDLE frames that are detected to be in error, encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfGFPIntervalEntry 1 } virtualIfGFPIntervalCHecSbError OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP frames that are detected to have single-bit errors in the Core header (i.e. cHEC field) only, encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfGFPIntervalEntry 2 } virtualIfGFPIntervalPtiMismatch OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of rreceived GFP frames that are detected with a mismatch on the PTI field (i.e. value of PTI is not equal to Client Data or Management frame), encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfGFPIntervalEntry 3 } virtualIfGFPIntervalExiMismatch OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP frames that are detected with a mismatch on the EXI field (i.e. value of EXI is not equal to NULL or LINEAR modes), encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfGFPIntervalEntry 4 } virtualIfGFPIntervalUpiMismatch OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP frames that are detected with a mismatch on the UPI field (i.e. value of EXI is not equal to 00000001), encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfGFPIntervalEntry 5 } virtualIfGFPIntervalTHecSbError OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP frames that are detected to only have single-bit errors in the Type header (i.e. tHEC field), encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfGFPIntervalEntry 6 } virtualIfGFPIntervalTHecMbError OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated withthe number of received GFP frames that are detected to only have multi-bit errors in the Type header (i.e. tHEC field), encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfGFPIntervalEntry 7 } virtualIfGFPIntervalCidMismatch OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP frames that are detected to have a mismatch/unsupported value in the CID field only, encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfGFPIntervalEntry 8 } virtualIfGFPIntervalEHecSbError OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the number of received GFP frames that are detected to only have single-bit errors in the Extension header (i.e. eHEC field), encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfGFPIntervalEntry 9 } virtualIfGFPIntervalEHecMbError OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is associated with the the number of received GFP frames that are detected to only have multi-bit errors in the Extension header (i.e. eHEC field), encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours." ::= { virtualIfGFPIntervalEntry 10 } prtSonetConfig OBJECT IDENTIFIER ::= {sonetInterface 2} prtSonetGen OBJECT IDENTIFIER ::= {prtSonetConfig 1} prtSonetGenTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSonetGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Sonet/SDH general port configuration table." ::= { prtSonetGen 1} prtSonetGenEntry OBJECT-TYPE SYNTAX PrtSonetGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the Sonet/SDH general port configuration table." INDEX { prtSonetGenCnfgIdx, prtSonetGenIdx } ::= { prtSonetGenTable 1} PrtSonetGenEntry ::= SEQUENCE { prtSonetGenCnfgIdx Integer32, prtSonetGenIdx Integer32, prtSonetGenSdThreshold INTEGER, prtSonetGenEedThreshold INTEGER, prtSonetGenBerEnable INTEGER } prtSonetGenCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255). " ::= { prtSonetGenEntry 1} prtSonetGenIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex." ::= { prtSonetGenEntry 2} prtSonetGenSdThreshold OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), n3 (3), n4 (4), n5 (5), n6 (6), n7 (7), n8 (8), n9 (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "SD=Signal Degraded Threshold. Units: [10E-]. The threshold is 10E-x relative to the frequency of the data flow. x=3, 4, 5, 6, 7, 8, 9. n3= 10E-3 n4= 10E-4 n5= 10E-5 n6= 10E-6 n7= 10E-7 n8= 10E-8 n9= 10E-9 ." ::= { prtSonetGenEntry 3 } prtSonetGenEedThreshold OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), n3 (3), n4 (4), n5 (5), n6 (6), n7 (7), n8 (8), n9 (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "EED=Excessive Error Defect Threshold. Units: [10E-]. The threshold is 10E-x relative to the frequency of the data flow. x=3, 4, 5, 6, 7, 8, 9. n3= 10E-3 n4= 10E-4 n5= 10E-5 n6= 10E-6 n7= 10E-7 n8= 10E-8 n9= 10E-9 ." ::= { prtSonetGenEntry 4 } prtSonetGenBerEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the activation of the Line Ber (Bit Error Rate), means whether SD and EED threshold parameters will be enabled." ::= { prtSonetGenEntry 5 } --STM-1 ports prtSonetStm1 OBJECT IDENTIFIER ::= {prtSonetConfig 2} prtSonetStm1Table OBJECT-TYPE SYNTAX SEQUENCE OF PrtSonetStm1Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Sonet/SDH STM-1 port configuration table." ::= { prtSonetStm1 1} prtSonetStm1Entry OBJECT-TYPE SYNTAX PrtSonetStm1Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the Sonet/SDH STM-1 port configuration table." INDEX { prtSonetStm1CnfgIdx, prtSonetStm1Idx } ::= { prtSonetStm1Table 1} PrtSonetStm1Entry ::= SEQUENCE { prtSonetStm1CnfgIdx Integer32, prtSonetStm1Idx Integer32, prtSonetStm1ClockSrc INTEGER, prtSonetStm1DccMode INTEGER, prtSonetStm1RoutingProt INTEGER, prtSonetStm1MngProt INTEGER, prtSonetStm1OperationalMode INTEGER, prtSonetStm1VoiceChannel INTEGER } prtSonetStm1CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255). " ::= { prtSonetStm1Entry 1} prtSonetStm1Idx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex." ::= { prtSonetStm1Entry 2} prtSonetStm1ClockSrc OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), internal (2), lbt (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock Source of the STM-1 port. lbt = Loop Back Timing." ::= { prtSonetStm1Entry 3 } prtSonetStm1DccMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), none (2), d1ToD3 (3), d4ToD12 (4), d1 (5), d2 (6), d3 (7), d4 (8), d5 (9), d6 (10), d7 (11), d8 (12), d9 (13), d10 (14), d11 (15), d12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "DCC Mode. DCC=Data Communication Channel. d1ToD3 = D1-D3 bytes are used (RS=Regeneration Section). d4ToD12= D4-D12 bytes are used (MS=Multiplexing Section). d1.... d12 enable user to select single DCC byte " ::= { prtSonetStm1Entry 4 } prtSonetStm1RoutingProt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), proprietary (3), rip2 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Routing Protocol." ::= { prtSonetStm1Entry 5 } prtSonetStm1MngProt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), -- none (2) proprietary (3), -- rip2 (4) ppp (5), frameRelay (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Management Protocol over DCC: Proprietary, PPP or Frame Relay." ::= { prtSonetStm1Entry 6 } prtSonetStm1OperationalMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), terminal (2), linear (3), linearProtection (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Operational Mode. linear - cannot be selected when there is Redundancy between the STM-1 ports." ::= { prtSonetStm1Entry 7 } prtSonetStm1VoiceChannel OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), e1Byte (3), e2Byte (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter enable user to select whether voice channel will be transferred using E1 byte, E2 Byte, or not at all." ::= { prtSonetStm1Entry 8 } --SONET/SDH VC-3, VC-4 and VC-12 ports parameters prtSonetVc OBJECT IDENTIFIER ::= {prtSonetConfig 3} prtSonetVcTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSonetVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Sonet/SDH VC port configuration table." ::= { prtSonetVc 1} prtSonetVcEntry OBJECT-TYPE SYNTAX PrtSonetVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the Sonet/SDH VC port configuration table." INDEX { prtSonetVcCnfgIdx, prtSonetVcIdx } ::= { prtSonetVcTable 1} PrtSonetVcEntry ::= SEQUENCE { prtSonetVcCnfgIdx Integer32, prtSonetVcIdx Integer32, prtSonetVcJTxPathTraceEnable INTEGER, prtSonetVcJRxPathTraceEnable INTEGER, prtSonetVcJPathTrace DisplayString, prtSonetVcConnect INTEGER } prtSonetVcCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255). " ::= { prtSonetVcEntry 1} prtSonetVcIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex." ::= { prtSonetVcEntry 2} prtSonetVcJTxPathTraceEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable Transmitting Jy Path Trace. y=1, 2: J1 - for VC-4 layer J2 - for VC-12 layer." ::= { prtSonetVcEntry 3 } prtSonetVcJRxPathTraceEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable checking Jy Path Trace. y=1, 2: J1 - for VC-4 layer J2 - for VC-12 layer." ::= { prtSonetVcEntry 4 } prtSonetVcJPathTrace OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "Jy Path Trace. y=1, 2: J1 - for VC-4 layer J2 - for VC-12 layer. This object is applicable only if one of the previous 2 objects is 'enable'." ::= { prtSonetVcEntry 5 } prtSonetVcConnect OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Connect VCn (n - 11,12,2,3,4) port (yes/no)." ::= { prtSonetVcEntry 6 } --TU-12 (within VC-4) Connect Table prtSonetTuTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSonetTuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch)." ::= { prtSonetVc 2} prtSonetTuEntry OBJECT-TYPE SYNTAX PrtSonetTuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtSonetTuCnfgIdx, prtSonetTuPrtIdx, prtSonetTuIdx, prtSonetTuConPrtIdx } ::= { prtSonetTuTable 1} PrtSonetTuEntry ::= SEQUENCE { prtSonetTuCnfgIdx Integer32, prtSonetTuPrtIdx Integer32, prtSonetTuIdx Integer32, prtSonetTuConPrtIdx Integer32, prtSonetTuType INTEGER, prtSonetTuMode INTEGER, prtSonetTuRowStatus RowStatus } prtSonetTuCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255). " ::= { prtSonetTuEntry 1} prtSonetTuPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique port or interface number. For port numbering, see product's spec. For some products, the numbering can equal ifIndex." ::= { prtSonetTuEntry 2} prtSonetTuIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique TU (Tributary Unit) within VC-4. The valid TUs are 1..63." ::= { prtSonetTuEntry 3} prtSonetTuConPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the connected port, when prtSonetTuType=connect. For port numbering, see product's spec. For some products, the numbering can equal ifIndex. notApplicable - will be indicated as 100." ::= {prtSonetTuEntry 4} prtSonetTuType OBJECT-TYPE SYNTAX INTEGER { connect (2), bypass (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "The type of TU (Tributary Unit). connect - connected to one of the E1 ports. bypass - bypassed to the other VC4 port. TUs that are not connected or bypassed, will not exist in this table." ::= { prtSonetTuEntry 5} prtSonetTuMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), addAndDrop (2), add (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "TU Mode of connection. addAndDrop - Add & Drop add - Add (TU receives from the E1 ports)." ::= { prtSonetTuEntry 6} prtSonetTuRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= { prtSonetTuEntry 7} -- SDH Cross Connect Table -- May be used also for SONET prtSonetXConnect OBJECT IDENTIFIER ::= {sonetInterface 3} prtSonetXConnectTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSonetXConnectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch)." ::= { prtSonetXConnect 1} prtSonetXConnectEntry OBJECT-TYPE SYNTAX PrtSonetXConnectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtSonetXConnectCnfgIdx, prtSonetXConnectPrtIdx, prtSonetXConnectConPrtIdx, prtSonetXConnectAUGIdx, prtSonetXConnectTUG3Idx, prtSonetXConnectTUG2Idx, prtSonetXConnectTUnIdx } ::= { prtSonetXConnectTable 1} PrtSonetXConnectEntry ::= SEQUENCE { prtSonetXConnectCnfgIdx Integer32, prtSonetXConnectPrtIdx Integer32, prtSonetXConnectConPrtIdx Integer32, prtSonetXConnectAUGIdx Integer32, prtSonetXConnectTUG3Idx Integer32, prtSonetXConnectTUG2Idx Integer32, prtSonetXConnectTUnIdx Integer32, prtSonetXConnectRowStatus RowStatus, prtSonetXConnectDirection INTEGER, prtSonetXConnectTuNumber INTEGER } prtSonetXConnectCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255). " ::= { prtSonetXConnectEntry 1} prtSonetXConnectPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique port or interface number. For port numbering, see product's spec. For some products, the numbering can equal ifIndex." ::= { prtSonetXConnectEntry 2} prtSonetXConnectConPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the connected port. For port numbering, see product's spec. For some products, the numbering can equal ifIndex. notApplicable - will be indicated as 255." ::= {prtSonetXConnectEntry 3} prtSonetXConnectAUGIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates an AUG (Administrative Unit Group) within STM-N. The valid AUGs values are: 1 for STM-1 1...4 for STM-4, 1..16 for STM-16 and 1..64 for STM-64 (STM-64) 255 designates NA." ::= { prtSonetXConnectEntry 4} prtSonetXConnectTUG3Idx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a TUG-3 (Tributary Unit Group 3) within VC-4. The valid TUG3s are values are 1..3. and 255 which designates NA " ::= { prtSonetXConnectEntry 5} prtSonetXConnectTUG2Idx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a TUG2 (Tributary Unit Group 2 ) within VC-3. The valid TUG2's values are 1..7 and 255 which designates NA " ::= { prtSonetXConnectEntry 6} prtSonetXConnectTUnIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a TUn within TUG-2 or TUG-3 (Tributary Unit n, where n is 2, 12 or 11 within TUG-2, or 3 within TUG-3) valid values are 1 for TU-2 1 for TU-3 1..4 for TU-11 1..3 for TU-12 255 designates NA" ::= { prtSonetXConnectEntry 7} prtSonetXConnectRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= { prtSonetXConnectEntry 8} prtSonetXConnectDirection OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), rx (2), tx (3), both (4) } MAX-ACCESS read-create STATUS current DESCRIPTION "TU direction of connection. rx=Drop tx=Add both = Add & Drop " ::= { prtSonetXConnectEntry 9} prtSonetXConnectTuNumber OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), tu2 (2), tu3 (3), tu11 (4), tu12 (5) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates which TU is used in prtSonetXConnectTUnIdx " ::= { prtSonetXConnectEntry 10} prtVcGroupCnfg OBJECT IDENTIFIER ::= {prtSonetConfig 4} vcGroupCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF VcGroupCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Virtual Concatenation Group configuration table." ::= { prtVcGroupCnfg 1 } vcGroupCnfgEntry OBJECT-TYPE SYNTAX VcGroupCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Virtual Concatenation Group configuration table." INDEX { vcGroupCnfgIdx,vcGroupCnfgNumber} ::= { vcGroupCnfgTable 1 } VcGroupCnfgEntry ::= SEQUENCE { vcGroupCnfgIdx Integer32, vcGroupCnfgNumber Integer32, vcGroupCnfgRowStatus RowStatus, vcGroupCnfgVcType INTEGER, vcGroupCnfgNoOfVCs Integer32, vcGroupCnfgLCAS INTEGER, vcGroupCnfgEncapsulation INTEGER, vcGroupCnfgGroupIfIndex InterfaceIndex, vcGroupCnfgRip2 INTEGER, vcGroupCnfgGfpChId Integer32 } vcGroupCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255). " ::= { vcGroupCnfgEntry 1} vcGroupCnfgNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Virtual Concatenation Group Number. For FCD=155 up to four groups are defined valid values are 1..4" ::= { vcGroupCnfgEntry 2} vcGroupCnfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= { vcGroupCnfgEntry 3} vcGroupCnfgVcType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), vc12 (2), --SDH vc3 (3), --SDH vc4 (4), --SDH vt1dot5 (5), --SONET VT1.5 sts1 (6) --SONET STS-1 /SPE } MAX-ACCESS read-create STATUS current DESCRIPTION "User may select type of SDH Virtual Containers (VC) (SONET Virtual Tributaries VT ) to be concatenated in this Virtual Concatenation Group. For SDH, values 2,3,4 are valid. For SONET, values 5 and 6 are valid." ::= { vcGroupCnfgEntry 4} vcGroupCnfgNoOfVCs OBJECT-TYPE SYNTAX Integer32 (0..84) MAX-ACCESS read-create STATUS current DESCRIPTION "User may select number of Virtual Containers (VC) (SONET Virtual Tributaries VT ) to be concatenated in this Virtual Concatenation Group. Valid range for this number depends on type VC selected by vcGroupCnfgVCType For SDH, up to 63 VC12, or up to 3 VC3, or 1 VC4 are valid For SONET, up to 84 VT1.5 without LCAS, or 64 VT1.5 under LCAS control. or up tp 3 STS-1/SPE, or 1 STS-3" ::= { vcGroupCnfgEntry 5} vcGroupCnfgLCAS OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), lcasNotActive (2), lcasActive (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object controls Link Capacity Adjustment Scheme (LCAS) activation." ::= { vcGroupCnfgEntry 6} vcGroupCnfgEncapsulation OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), laps (2), -- Link access protocol S lapf (3), -- Link access protocol F (Frame relay) gfp (4) -- Generic Framing Procedure } MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables user to select encapsulation method." ::= { vcGroupCnfgEntry 7} vcGroupCnfgGroupIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex assigend to this group." ::= { vcGroupCnfgEntry 8} vcGroupCnfgRip2 OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object controls RIP 2. User may select to send RIP 2 message over selected group or not" ::= { vcGroupCnfgEntry 9} vcGroupCnfgGfpChId OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "Generic Framing Procedure (GFP) Channel ID, Valid only when vcGroupCnfgEncapsulation = gfp (4) Valid values are 0x00 - oxFF (hex) " ::= { vcGroupCnfgEntry 10} vcgGfpMuxCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF VcgGfpMuxCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Virtual Concatenation Group GFP Mux configuration table." ::= { prtVcGroupCnfg 2 } -- This table defines multiplexing scheme for GFP mux of -- Virtual Concatenation Groups: -- Primary group, Secondary group/s and bandwidth allocation -- to each group. vcgGfpMuxCnfgEntry OBJECT-TYPE SYNTAX VcgGfpMuxCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Virtual Concatenation Group GFP Mux configuration table." INDEX { vcgGfpMuxCnfgIdx,vcgGfpMuxCnfgMuxNumber} ::= { vcgGfpMuxCnfgTable 1 } VcgGfpMuxCnfgEntry ::= SEQUENCE { vcgGfpMuxCnfgIdx Integer32, vcgGfpMuxCnfgMuxNumber Integer32, vcgGfpMuxCnfgRowStatus RowStatus, vcgGfpMuxCnfgMuxName SnmpAdminString, vcgGfpMuxCnfgPrimeGroup Integer32, vcgGfpMuxCnfgGrpBwAlloc OCTET STRING } vcgGfpMuxCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the Index of the configuration being accessed. Index of 255 relates to the Temporary (Scratch) coninguration. For products that support several configurations, Set can be performed only to the Temporary Config (=255). " ::= { vcgGfpMuxCnfgEntry 1} vcgGfpMuxCnfgMuxNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Virtual Concatenation Group GFP Mux Number. For FCD=155 up to 2 GFP muxes can be created." ::= { vcgGfpMuxCnfgEntry 2} vcgGfpMuxCnfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= { vcgGfpMuxCnfgEntry 3} vcgGfpMuxCnfgMuxName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-create STATUS current DESCRIPTION "Virtual Concatenation Group, GFP Mux name." ::= { vcgGfpMuxCnfgEntry 4} vcgGfpMuxCnfgPrimeGroup OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Index of Virtual Concatenation Group used as Primary for the GFP mux created for FCD 155 four Virtual Concatenation Group are defined: 1 -> Virtual Concatenation Group 1 2 -> Virtual Concatenation Group 2 3 -> Virtual Concatenation Group 3 4 -> Virtual Concatenation Group 4" ::= { vcgGfpMuxCnfgEntry 5} vcgGfpMuxCnfgGrpBwAlloc OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the allocated bandwidth (BW) to each Virtual Concatenation Group (VCG). Each nibble indicates BW percentage, in 12.5% steps, assigned to a group. For FCD-155, there are 4 VCGs. One VCG is identified as primary group by vcGfpMuxConfPrimeGroup. Other VCGs may be secondaries. VCG with allocated BW value of zero does not belong to the GFPmux defined by GFP Mux number. ________________________________________ | Octet 0 | Octet 1 | |Nibble 4 Nibble 3| Nibble 2| Nibble 1| MSB | 7 6 5 4 | 3 2 1 0 | 7 6 5 4 | 3 2 1 0 | LSB VCG1 VCG2 VCG 3 VCG4 Nibble value - BW Percentage (0...7) (0 ...87.5%) 1 0001 12.5 % 2 0010 25% 3 0011 37.5 ..... 7 0111 87.5% at least one nibble must be greater that zero. Sum of alloacted BW must be 100%. Primary VCG BW must be greater than zero." ::= { vcgGfpMuxCnfgEntry 6} -- END-- -- file :v:\doc\rdv\mib\ver495\atm\NtePrtCo.txt -- -- ************************* -- file : NtePrtConfg.txt -- --Version: 1.0 --Date: 12.11.97 --By: Ilana Schvetz --File: v:\doc\rdv\mib\ver495\atm\NtePrtConfg.txt --Last Update: 15-Feb-04 by Yig'al Hachmon (back to original 495) -- Copyright 1997 RAD Data Communications, Ltd. -- All Rights Reserved. atmNte OBJECT IDENTIFIER ::= { radAtm 3 } atmNtePrt OBJECT IDENTIFIER ::= { atmNte 2 } atmNtePrtConfig OBJECT IDENTIFIER ::= { atmNtePrt 1 } atmNteEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD ATM products." ::= { atmNte 0 } atmNteConfIfTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteConfIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Physical interface configuration table." ::= { atmNtePrtConfig 1 } atmNteConfIfEntry OBJECT-TYPE SYNTAX AtmNteConfIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Physical interface configuration table. The ifIndex is of the lowest physical layer." INDEX { ifIndex} ::= { atmNteConfIfTable 1 } AtmNteConfIfEntry ::= SEQUENCE { atmConfIfTransmitClk INTEGER, atmConfIfLoopback INTEGER, atmConfIfFrameType INTEGER, atmConfIfCardType INTEGER, atmConfAtmIfVpiVciLimit INTEGER, atmConfIfHwFeatures INTEGER, atmConfIfOutputRate Integer32, atmConfIfInputRate Integer32, atmConfAlarmForwarding INTEGER, atmConfIfAllocatedBw Integer32, atmConfIfLowerVpi Integer32, atmConfIfOamMode INTEGER } atmConfIfTransmitClk OBJECT-TYPE SYNTAX INTEGER { internal(2), external(3), loopback(4), adaptive(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "The transmit clock of the port." ::= { atmNteConfIfEntry 1 } atmConfIfLoopback OBJECT-TYPE SYNTAX INTEGER { internal(2), external(3), disable(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Interface Loopback." ::= { atmNteConfIfEntry 2 } atmConfIfFrameType OBJECT-TYPE SYNTAX INTEGER { other (1), sonet (2), sdh (3), direct (4), plcpInternal (5), plcpExternal (6), e3 (7), ethCrcTrans (8), ethCrcNotTrans (9), directNoScrmbling (10), plcpInternalNoScrmbling (11), plcpExternalNoScrmbling (12) } MAX-ACCESS read-write STATUS current DESCRIPTION "The frame type. Valid values for a 155M interface: sonet(2), sdh(3). Valid values for a T3 interface: direct(4), plcpInternal(5), plcpExternal(6), directNoScrmbling(10), plcpInternalNoScrmbling(11), plcpExternalNoScrmbling(12). Valid values for Ethernet interface: ethCrcTrans (8), ethCrcNotTrans(9). (DS1 interfaces frame type is specified in the DSX1 mib)." ::= { atmNteConfIfEntry 3 } atmConfIfCardType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), sc13m-155(2), st13s-155(3), st13l-155(4), utp-155(5), cx-bnc-155(6), e3(7), t3(8), e1(9), e1-ltu(10), fc13l-155(11), fc13lh-155(12), fc15lh-155(13), fc13l-e3(14), fc13lh-e3(15), fc15lh-e3(16), fc13l-t3(17), fc13lh-t3(18), fc15lh-t3(19) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The card type." ::= { atmNteConfIfEntry 4 } atmConfAtmIfVpiVciLimit OBJECT-TYPE SYNTAX INTEGER { bits15(2), bits17(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The limit on the sum of the VPI+VCI bits for this interface." ::= { atmNteConfIfEntry 5 } atmConfIfHwFeatures OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "HW features command." ::= { atmNteConfIfEntry 6 } atmConfIfOutputRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the output rate in cells/sec, which is supported per port. Successfully setting this parameter is dependent on all other ports values calculations, which are described in the NMS SRS." ::= { atmNteConfIfEntry 7 } atmConfIfInputRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the input rate in cells/sec, which is supported per port. Successfully setting this parameter is dependent on all other ports values calculations, which are described in the NMS SRS." ::= { atmNteConfIfEntry 8 } atmConfAlarmForwarding OBJECT-TYPE SYNTAX INTEGER { disable(2), enable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables Path AIS Alarm forwarding upon a failure detection. The following might be considered as a failure: LOS, LOF, LOC, SLM, LOP, Path AIS and Line AIS. disable(2) - will not forward an alarm upon a failure on this port. enable(3) - will forward an alarm upon a failure on this port." ::= { atmNteConfIfEntry 9 } atmConfIfAllocatedBw OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total VC Bandwidth Allocation." ::= { atmNteConfIfEntry 10 } atmConfIfLowerVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Lower possible VPI." ::= { atmNteConfIfEntry 11 } atmConfIfOamMode OBJECT-TYPE SYNTAX INTEGER { -- intermediate(1), segmentTermination(2), endToEndTermination(3) -- vpEndToEndVcSegment(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "OAM support Mode, which determines the interface's location in a segment wise." ::= { atmNteConfIfEntry 12 } atmNteAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteAlarmIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The interface Alarm table." ::= { atmNtePrtConfig 2 } atmNteAlarmIfEntry OBJECT-TYPE SYNTAX AtmNteAlarmIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the interface Alarm table." INDEX { ifIndex} ::= { atmNteAlarmIfTable 1 } AtmNteAlarmIfEntry ::= SEQUENCE { atmInterfaceActiveAlarms Integer32, atmThresholdSectionBIP Integer32, atmThresholdLineBIP Integer32, atmThresholdLineFEBE Integer32, atmThresholdPathBIP Integer32, atmThresholdPathFEBE Integer32, atmThresholdErroredCells Integer32, atmThresholdLostCells Integer32, atmThresholdMisinsertedCells Integer32, atmInterfaceAlarmStatus INTEGER, atmInterfaceMaskAlarms Integer32 } atmInterfaceActiveAlarms OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A Bit String of the active alarms on this interface. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - LOS 2 - LOF 3 - Line AIS (SONET)/ PLCP LOF (DS3) 4 - LOP 5 - Path AIS 6 - SLM 7 - LCD 8 - Line RDI (SONET)/ PLCP Yellow (DS3) 9 - Path RDI (SONET)/ RDI (DS3) 10 - Section BIP (SONET)/ P1/P2 (DS3) > Threshold 11 - Line BIP (SONET)/ PLCP BIP (DS3) > Threshold 12 - Line FEBE (SONET)/ PLCP FEBE (DS3) > Threshold 13 - Path BIP > Threshold 14 - Path FEBE > Threshold 15 - HW Failure " ::= { atmNteAlarmIfEntry 1 } atmThresholdSectionBIP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Section BIPs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface." ::= { atmNteAlarmIfEntry 2 } atmThresholdLineBIP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Line BIPs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface." ::= { atmNteAlarmIfEntry 3 } atmThresholdLineFEBE OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Line FEBEs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface." ::= { atmNteAlarmIfEntry 4 } atmThresholdPathBIP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Path BIPs are greater than this threshold, an active alarm is raised." ::= { atmNteAlarmIfEntry 5 } atmThresholdPathFEBE OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Path FEBEs are greater than this threshold, an active alarm is raised." ::= { atmNteAlarmIfEntry 6 } atmThresholdErroredCells OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Errored Cells are greater than this threshold, an active alarm is raised." ::= { atmNteAlarmIfEntry 7 } atmThresholdLostCells OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Lost Cells are greater than this threshold, an active alarm is raised." ::= { atmNteAlarmIfEntry 8 } atmThresholdMisinsertedCells OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Misinserted Cells are greater than this threshold, an active alarm is raised." ::= { atmNteAlarmIfEntry 9 } atmInterfaceAlarmStatus OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The variable is on(3) when there is any active alarm on this interface." ::= { atmNteAlarmIfEntry 10 } atmInterfaceMaskAlarms OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "A Bit String of alarms mask on this interface. An up bit (1) means that the respective alarm is masked. A down bit (0) means no mask. The mask is supported for the following alarms: 1 - LOS " ::= { atmNteAlarmIfEntry 11 } atmNteConfVpTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteConfVpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VP configuration table. The table is an extension to the atmVplTable of RFC-1695." ::= { atmNtePrtConfig 3 } atmNteConfVpEntry OBJECT-TYPE SYNTAX AtmNteConfVpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VP configuration table. ifIndex of the ATM layer." INDEX { ifIndex, atmVplVpi } ::= { atmNteConfVpTable 1 } AtmNteConfVpEntry ::= SEQUENCE { atmConfVpPolicing INTEGER, atmConfVpCCAdminStatus INTEGER, atmConfVpLoopbackAdminStatus INTEGER, atmConfVpLoopbackSinkAddress OCTET STRING, atmConfVpCongestionControl OCTET STRING, atmConfVpCCDirection INTEGER, atmConfVpCreationTime DateAndTime, atmConfVpOamSupport INTEGER, atmConfVpCCOperStatus INTEGER, atmConfVpLoopbackTraffic INTEGER, atmConfVpLoopbackFailureInd INTEGER, atmConfVpLoopbackFailureThreshold Integer32, atmConfVpOamDirection INTEGER } atmConfVpPolicing OBJECT-TYPE SYNTAX INTEGER { none(1), police(2), monitor(3), shaping(4), policingAndShaping(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Policing method desired for this VPL." ::= { atmNteConfVpEntry 1 } atmConfVpCCAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (2), down (3), source(4), -- agent send Oam CC cells sink (5), -- agent check received Oam CC cells listenToActivationCells (6), originateActivationCells(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "up(2) - Activate Continuity Check (CC). down(3) - Deactivate CC. source(4) - Activate OAM CC(Continuity Check) of local agent ( start sending Oam cells to the remote side ). sink(5) - Activate CC of remote agent ( start receiving Oam cells from remote side ). listenToActivationCells (6) - Passive listener till gets an activation request originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection." ::= {atmNteConfVpEntry 2} atmConfVpLoopbackAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(2), down(3), llid(4), segment(5), endToEnd(6), segmentLlid(7), endToEndLlid(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "up(2) - Start loopback OAM cells. down(3) - Stop sending loopback OAM cells. For ace2002: up(2) - Transmitting LB cells with llid all ones (i.e. FFFF..FF) down(3) - Not transmitting LB cells. llid(4) - Transmitting LB cells with llid indicated in the address field. segment(5) - Transmitting Segment LB cells with llid all ones. endToEnd(6) - Transmitting End to End LB cells with llid all ones. segmentLlid(7) - Transmitting Segment LB cells with llid indicated in the address field. endToEndLlid(8) - Transmitting LB cells with llid indicated in the address field. This parameter value might be in conflict with atmConfVpOamSupport value, since this parameter is for LB, while atmConfVpOamSupport is for any other OAM cells." ::= {atmNteConfVpEntry 3} atmConfVpLoopbackSinkAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Destination address. For ace101: 2 bytes are used. For ace2002: 16 bytes are used." ::= {atmNteConfVpEntry 4} atmConfVpCongestionControl OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Each bit indicates a selection of one option as the following description. All combinations are possible and legal. The codes are: 1 - EPD 2 - CLP 4 - EFCI" ::= {atmNteConfVpEntry 5} atmConfVpCCDirection OBJECT-TYPE SYNTAX INTEGER { both (2), source(4), sink (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "both(2) - Agent send OAM CC cells and check received OAM CC cells source(4)- Agent send OAM CC cells. sink(5) - Agent checks received OAM CC cells." ::= {atmNteConfVpEntry 6} atmConfVpCreationTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "A date-time in which the VP was created." ::= { atmNteConfVpEntry 7 } atmConfVpOamSupport OBJECT-TYPE SYNTAX INTEGER { intermediate(1), segmentTermination(2), endToEndTermination(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "OAM support mode, which determines the device location in a segment wise." ::= { atmNteConfVpEntry 8 } atmConfVpCCOperStatus OBJECT-TYPE SYNTAX INTEGER { initial (1), source(4), sink (5), both (8), timeout (9), denied (10), conflict (11), manual (12) } MAX-ACCESS read-only STATUS current DESCRIPTION " initial(1) - The CC activation process is not started. source(4) - Agent sends OAM CC cells. sink(5) - Agent checks received OAM CC cells. both (8) - OAM CC of local and remote agents activation. timeout (9) - Timeout occured on receiving answer from the remote agent. denied (10) - CC activation process rejected by remote agent. conflict (11) - local and remote sides requested activation simultaneously. manual (12) - OAM CC of local agent activated manually. " ::= {atmNteConfVpEntry 9} atmConfVpLoopbackTraffic OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter has both command and status meanings: off(2) - Set to 'Off' will Stop traffic loop. Getting this value means that the loop is not running. on (3) - Set to 'On' will start traffic loop. Getting this value means that the loop is currently running." ::= {atmNteConfVpEntry 10} atmConfVpLoopbackFailureInd OBJECT-TYPE SYNTAX INTEGER { disabled(2), segmentAis(3), segmentRdi(4), segmentAisAndRdi(5), endToEndAis(6), endToEndRdi(7), endToEndAisAndRdi(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows user to define the Indication that will be created upon a LB cell failure. disabled(2) - no indication will be created. segmentAis(3) - will cause Tx of a segment AIS. segmentRdi(4) - will cause Tx of a segment RDI. segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI. endToEndAis(6) - will cause Tx of an End to End AIS. endToEndRdi(7) - will cause Tx of an End to End RDI. endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI. Default: disabled(2)." ::= {atmNteConfVpEntry 11} atmConfVpLoopbackFailureThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of the LB failures before starting transmission of the Indication defined by atmConfVcLoopbackFailureInd. Range: 1..16. Default: 1." ::= {atmNteConfVpEntry 12} atmConfVpOamDirection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), downStream (2), upStream (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The direction of OAM cell insertion. downStream(2) - The OAM cell will be inserted in downStream. upStream(3) - The OAM cell will be inserted in upStream." ::= {atmNteConfVpEntry 13} --Alarm Table atmNteAlarmVpTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteAlarmVpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VP Alarm table." ::= { atmNtePrtConfig 5 } atmNteAlarmVpEntry OBJECT-TYPE SYNTAX AtmNteAlarmVpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VP Alarm table. ifIndex of the ATM layer." INDEX { ifIndex, atmNteVpAlarmVpi} ::= { atmNteAlarmVpTable 1 } AtmNteAlarmVpEntry ::= SEQUENCE { atmNteVpAlarmVpi Integer32, atmNteVpActiveAlarms Integer32 } atmNteVpAlarmVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI on which there is an active alarm." ::= { atmNteAlarmVpEntry 1 } atmNteVpActiveAlarms OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A Bit String of the active alarms on this VP. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - VP AIS 2 - VP Loss Of Continuity 3 - VP RDI Reception 4 - VP Errored Cells > Threshold 5 - VP Lost Cells > Threshold 6 - VP Misinserted Cells > Threshold 9 - VP Loopback Failure " ::= { atmNteAlarmVpEntry 2 } atmNteAlarmVcTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteAlarmVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VC Alarm table." ::= { atmNtePrtConfig 6 } atmNteAlarmVcEntry OBJECT-TYPE SYNTAX AtmNteAlarmVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VC Alarm table. ifIndex of the ATM layer." INDEX { ifIndex, atmNteVcAlarmVpi, atmNteVcAlarmVci} ::= { atmNteAlarmVcTable 1 } AtmNteAlarmVcEntry ::= SEQUENCE { atmNteVcAlarmVpi Integer32, atmNteVcAlarmVci Integer32, atmNteVcActiveAlarms Integer32 } atmNteVcAlarmVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VC on which there is an active alarm." ::= { atmNteAlarmVcEntry 1 } atmNteVcAlarmVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the VC on which there is an active alarm." ::= { atmNteAlarmVcEntry 2 } atmNteVcActiveAlarms OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A Bit String of the active alarms on this VC. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - VC AIS 2 - VC Loss Of Continuity 3 - VC RDI 4 - VC Errored Cells > Threshold 5 - VC Lost Cells > Threshold 6 - VC Misinserted Cells > Threshold 7 - Tx VC AIS 8 - Tx VC RDI 9 - VC Loopback Failure " ::= { atmNteAlarmVcEntry 3 } -- -- file :v:\doc\rdv\mib\ver495\atm\confVcTa.txt -- -- file : ConfVcTable.txt -- --Version: 1.0 --Date: 12.11.97 --By: Ilana Schvetz --File: v:\doc\rdv\mib\ver495\atm\ConfVcTable.txt --Last Update: 15-Dec-02 by Shay Harari. -- ******************************************************* -- Configuration Vc Table -- ******************************************************* --atmNte OBJECT IDENTIFIER ::= { radAtm 3 } --atmNtePrt OBJECT IDENTIFIER ::= { atmNte 2 } --atmNtePrtConfig OBJECT IDENTIFIER ::= { atmNtePrt 1 } atmNteConfVcTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteConfVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VC configuration table. The table is an extension to the atmVclTable of RFC-1695." ::= { atmNtePrtConfig 4 } atmNteConfVcEntry OBJECT-TYPE SYNTAX AtmNteConfVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VC configuration table. ifIndex of the ATM layer." INDEX { ifIndex , atmVclVpi, atmVclVci} ::= { atmNteConfVcTable 1 } AtmNteConfVcEntry ::= SEQUENCE { atmConfVcPolicing INTEGER, atmConfVcCCAdminStatus INTEGER, atmConfVcLoopbackAdminStatus INTEGER, atmConfVcLoopbackSinkAddress OCTET STRING, atmConfVcCongestionControl OCTET STRING, atmConfVcCCDirection INTEGER, atmConfVcCreationTime DateAndTime, atmConfVcOamSupport INTEGER, atmConfVcCCActivationCtrl INTEGER, atmConfVcCCOperStatus INTEGER, atmConfVcLoopbackTraffic INTEGER, atmConfVcLoopbackFailureInd INTEGER, atmConfVcLoopbackFailureThreshold Integer32, atmConfVcOamDirection INTEGER, atmConfVcName DisplayString, atmConfVcConnected INTEGER } atmConfVcPolicing OBJECT-TYPE SYNTAX INTEGER { none(1), police(2), monitor(3), shaping(4), policingAndShaping(5), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Policing method desired for this VCL." ::= { atmNteConfVcEntry 1 } atmConfVcCCAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(2), down(3), source(4), -- agent send Oam CC cells sink(5), -- agent check received Oam CC cells listenToActivationCells (6), originateActivationCells(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "up(2) - Activate Continuity Check (CC). down(3) - Deactivate CC. source(4) - Activate OAM CC(Continuity Check) of local agent ( start sending Oam cells to the remote side ). sink(5) - Activate CC of remote agent ( start receiving Oam cells from remote side). listenToActivationCells (6) - Passive listener till gets an activation request originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection." ::= {atmNteConfVcEntry 2} atmConfVcLoopbackAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(2), down(3), llid(4), segment(5), endToEnd(6), segmentLlid(7), endToEndLlid(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "up(2) - Start loopback OAM cells. down(3) - Stop sending loopback OAM cells. For ace2002: up(2) - Transmitting LB cells with llid all ones (i.e. FFFF..FF) down(3) - Not transmitting LB cells. llid(4) - Transmitting LB cells with llid indicated in the address field. segment(5) - Transmitting Segment LB cells with llid all ones. endToEnd(6) - Transmitting End to End LB cells with llid all ones. segmentLlid(7) - Transmitting Segment LB cells with llid indicated in the address field. endToEndLlid(8) - Transmitting LB cells with llid indicated in the address field. This parameter value might be in conflict with atmConfVcOamSupport value, since this parameter is for LB, while atmConfVcOamSupport is for any other OAM cells." ::= {atmNteConfVcEntry 3} atmConfVcLoopbackSinkAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Destination address. For ace101: 2 bytes are used. For ace2002: 16 bytes are used." ::= {atmNteConfVcEntry 4} atmConfVcCongestionControl OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Each bit indicates a selection of one option as the following description. All combinations are possible and legal. The codes are: 1 - EPD 2 - CLP 4 - EFCI. For ace2002: 1 - Packet Discard." ::= {atmNteConfVcEntry 5} atmConfVcCCDirection OBJECT-TYPE SYNTAX INTEGER { both (2), none (3), source(4), sink (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "both(2) - Agent send OAM CC cells and check receivev OAM CC cells none(3) - Agent does not send and does not check received OAM CC cells. source(4)- Agent send OAM CC cells. sink(5) - Agent checks received OAM CC cells." ::= {atmNteConfVcEntry 6} atmConfVcCreationTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "A date-time in which the VC was created." ::= { atmNteConfVcEntry 7 } atmConfVcOamSupport OBJECT-TYPE SYNTAX INTEGER { intermediate(1), segmentTermination(2), endToEndTermination(3), segmentAndEndToEnd(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "OAM support mode, which determines the device location in a segment wise. segmentAndEndToEnd - In this mode the OAM cells are generated before the ABM (ATM Buffer Manager), so that the PCR and CDVT will not be affected." ::= { atmNteConfVcEntry 8 } atmConfVcCCActivationCtrl OBJECT-TYPE SYNTAX INTEGER { manual(1), activator(2), listener(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "manual(1) - CC Activation process is disable activator(2) - ACE-101 initiate CC Activation process listener(3) - ACE-101 wait to CC Activation request from remote side." ::= { atmNteConfVcEntry 9 } atmConfVcCCOperStatus OBJECT-TYPE SYNTAX INTEGER { initial(1), up(2), down(3), source(4), -- agent send Oam CC cells sink(5), -- agent check received Oam CC cells both (8), timeout (9), denied (10), conflict (11), manual (12) } MAX-ACCESS read-only STATUS current DESCRIPTION "initial (1) - The CC activation process is not started. up (2) - Continuity Check (CC) activated. down (3) - CC deactivated. source (4) - OAM CC(Continuity Check) of local agent activated. sink (5) - OAM CC of remote agent activated. both (8) - OAM CC of local and remote agents activation. timeout (9) - Timeout occured on receiving answer from the remote agent. denied (10) - CC activation process rejected by remote agent. conflict (11) - local and remote sides requested activation simultaneously. manual (12) - OAM CC of local agent activated manually. " ::= { atmNteConfVcEntry 10 } atmConfVcLoopbackTraffic OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter has both command and status meanings: off(2) - Set to 'Off' will Stop traffic loop. Getting this value means that the loop is not running. on (3) - Set to 'On' will start traffic loop. Getting this value means that the loop is currently running." ::= {atmNteConfVcEntry 11} atmConfVcLoopbackFailureInd OBJECT-TYPE SYNTAX INTEGER { disabled(2), segmentAis(3), segmentRdi(4), segmentAisAndRdi(5), endToEndAis(6), endToEndRdi(7), endToEndAisAndRdi(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows user to define the Indication that will be created upon a LB cell failure. disabled(2) - no indication will be created. segmentAis(3) - will cause Tx of a segment AIS. segmentRdi(4) - will cause Tx of a segment RDI. segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI. endToEndAis(6) - will cause Tx of an End to End AIS. endToEndRdi(7) - will cause Tx of an End to End RDI. endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI. Default: disabled(2)." ::= {atmNteConfVcEntry 12} atmConfVcLoopbackFailureThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of the LB failures before starting transmission of the Indication defined by atmConfVcLoopbackFailureInd. Range: 1..16. Default: 1." ::= {atmNteConfVcEntry 13} atmConfVcOamDirection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), downStream (2), upStream (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The direction of OAM cell insertion. downStream(2) - The OAM cell will be inserted in downStream. upStream(3) - The OAM cell will be inserted in upStream." ::= {atmNteConfVcEntry 14} atmConfVcName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "VC Name." ::= {atmNteConfVcEntry 15} atmConfVcConnected OBJECT-TYPE SYNTAX INTEGER { notConnected(1), mng(2), bridgePort(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates whether this VC is connected." ::= {atmNteConfVcEntry 16} -- -- file :v:\doc\rdv\mib\ver485\atm\radima.txt -- -- RAD-IMA-MIB DEFINITIONS ::= BEGIN --Title: RAD-IMA MIB -- -- Copyright 1998 RAD Data Communications, Ltd. -- All Rights Reserved. -- IMPORTS -- OBJECT-TYPE FROM RFC-1212 -- radWan FROM RAD-GEN-MIB; -- RAD-IMA MIB --Title: RAD's IMA INTERFACE MIB --Version: 1.0 --Date: 15.09.98 --By: Ilana Schvetz --File: radima.mib -- Last Update 20.01.02 by Ilana Schvetz radAtmIma OBJECT IDENTIFIER ::= {radAtm 5} imaPrimaryClk OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), link1(2), link2(3), link3(4), link4(5), automatic(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock source to be transmitted to the user side, where user module is in 'External' clock source." ::= { radAtmIma 1 } -- An extension to the Link Table imaXLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF ImaXLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IMA Link Status and Configuration table. This table contains additional objects for the link table." ::= { radAtmIma 2 } imaXLinkEntry OBJECT-TYPE SYNTAX ImaXLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the IMA Link table." -- AUGMENTS { imaLinkTable } INDEX { imaLinkIfIndex } ::= { imaXLinkTable 1 } ImaXLinkEntry ::= SEQUENCE { imaLinkDirection INTEGER, imaLinkItcLBClkSrc INTEGER } imaLinkDirection OBJECT-TYPE SYNTAX INTEGER { rx(1), tx(2), both(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "the Link direction." -- DEFAULT { both } ::= { imaXLinkEntry 1 } imaLinkItcLBClkSrc OBJECT-TYPE SYNTAX INTEGER { link1(1), link2(2), link3(3), link4(4), internal (5), external (6), automatic(7), loopback (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock source for the current Tx-line." ::= { imaXLinkEntry 2 } -- An extension to the Group Table imaXGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF ImaXGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IMA group Status and Configuration table. This table contains additional objects for the Group table." ::= { radAtmIma 3 } imaXGroupEntry OBJECT-TYPE SYNTAX ImaXGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the IMA Group table." -- AUGMENTS { imaGroupTable } INDEX { imaGroupIndex } ::= { imaXGroupTable 1 } ImaXGroupEntry ::= SEQUENCE { imaGroupVersion INTEGER, imaGroupCtcTxClkSrc INTEGER, imaGroupCtcTxClkSrcPort Integer32 } imaGroupVersion OBJECT-TYPE SYNTAX INTEGER { ver10(1), ver11(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "IMA Version." ::= { imaXGroupEntry 1 } imaGroupCtcTxClkSrc OBJECT-TYPE SYNTAX INTEGER { link1 (1), link2 (2), link3 (3), link4 (4), internal (5), external (6), automatic (7), loopback (8), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The source of the transmitted, common, Clock Source. Applicable if imaGroupNeTxClkMode=ctc(1). Automatic - Dynamic source, taken from the currently reference link. Internal - taken from the Internal clock on card. Loopback - Looped back from one of the ports. In this case a specific port should be selected for imaGroupCtcTxClkSrcPort parameter. Link N - Clock will be looped from one of the links." ::= { imaXGroupEntry 2 } imaGroupCtcTxClkSrcPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is valid only when imaGroupCtcTxClkSrc=loopback. The value may be any port identifier." ::= { imaXGroupEntry 3 } -- IMA Traps --NOTIFICATIONS atmImaGroupStatusChangeTrap NOTIFICATION-TYPE OBJECTS { imaGroupFailureStatus } STATUS current DESCRIPTION "This trap indicates IMA Group status change." ::= { radSysAtmEvents 80 } -- -- file :v:\doc\rdv\mib\ver495\radhdlc.txt -- -- RAD-HDLC-MIB DEFINITIONS ::= BEGIN --Title: RAD-HDLC MIB -- -- Copyright 1998 RAD Data Communications, Ltd. -- All Rights Reserved. --Title: RAD's HDLC MIB --Version: 1.0 --Date: 15.09.98 --By: Ilana Schvetz --File: radhdlc.mib -- -- Last Update: 09-Oct-02 By Ilana Schvetz hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5} hdlcTable OBJECT-TYPE SYNTAX SEQUENCE OF HdlcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The HDLC configuration table." ::= { hdlcMibObjects 1 } hdlcEntry OBJECT-TYPE SYNTAX HdlcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD HDLC Table." INDEX { ifIndex } ::= { hdlcTable 1 } HdlcEntry ::= SEQUENCE { hdlcProtocol INTEGER, hdlcRateResolution INTEGER, hdlcTxClockSource INTEGER, hdlcTerminalMode INTEGER, hdlcLoopbackState INTEGER, hdlcTxClockPolarity INTEGER, hdlcFlowControl INTEGER, hdlcLineRate Integer32, hdlcRxClockMode INTEGER, hdlcLOF Gauge32, hdlcRxClockPolarity INTEGER } hdlcProtocol OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), v35(2), x21(3), rs530(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The HDLC protocol type V35 - HDLC encapsulated over V35 X21 - HDLC encapsulated over X21 RS530 - HDLC encapsulated over RS530" ::= { hdlcEntry 1 } hdlcRateResolution OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), nx56Kbps(2), nx64Kbps(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The baud rate of the internal clock." ::= { hdlcEntry 2 } hdlcTxClockSource OBJECT-TYPE SYNTAX INTEGER { internal(1), external(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The baud rate of the internal clock." ::= { hdlcEntry 3 } hdlcTerminalMode OBJECT-TYPE SYNTAX INTEGER { dce(1), dte(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "." ::= { hdlcEntry 4 } hdlcLoopbackState OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), internal(2), external(3), disable(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "internal - All data coming from the network port is looped back external - All data comming from the line is looped back." ::= { hdlcEntry 5 } hdlcTxClockPolarity OBJECT-TYPE SYNTAX INTEGER { normal (1), inverse(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "normal - The transmitted data is sampled at the middle of bit time inverse - The transmitted data is sampled at the end of the bit time (high data rate/long cable)." ::= { hdlcEntry 6 } hdlcFlowControl OBJECT-TYPE SYNTAX INTEGER { disable(1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable the CTS/RTS flow control signals." ::= { hdlcEntry 7 } hdlcLineRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The rate values for HDLC are n*56/64Kbps, where 1<=n<=32, 64, 128 and the following values: 1544, 3088, 6176. The rate values for HSSI is nMbps, where 1<=n<=52." ::= { hdlcEntry 8 } hdlcRxClockMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), internal (2), external (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "." ::= { hdlcEntry 9 } hdlcLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of seconds the port is in Loss Of Frame state." ::= { hdlcEntry 10 } hdlcRxClockPolarity OBJECT-TYPE SYNTAX INTEGER { normal (1), inverse(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "normal - The received data is sampled at the middle of bit time inverse - The received data is sampled at the end of the bit time (high data rate/long cable)." ::= { hdlcEntry 11 } hdlcPerformance OBJECT IDENTIFIER ::= {hdlcMibObjects 2} hdlcCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF HdlcCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The HDLC Current table." ::= { hdlcPerformance 1 } hdlcCurrentEntry OBJECT-TYPE SYNTAX HdlcCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the HDLC Current table." INDEX { hdlcCurrentIfIndex } ::= { hdlcCurrentTable 1 } HdlcCurrentEntry ::= SEQUENCE { hdlcCurrentIfIndex Integer32, hdlcCurrentStatus OCTET STRING, hdlcCurrentLOF Gauge32, hdlcCurrentInFrames Gauge32, hdlcCurrentInErrors Gauge32, hdlcCurrentOutFrames Gauge32, hdlcCurrentAbortedFrames Gauge32, hdlcCurrentLengthError Gauge32 } hdlcCurrentIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the HDLC interface. It may be ifIndex." ::= { hdlcCurrentEntry 1 } hdlcCurrentStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { hdlcCurrentEntry 2 } hdlcCurrentLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of seconds the port is in Loss Of Frame state, encountered by the HDLC interface in the current 15 minute interval." ::= { hdlcCurrentEntry 3 } hdlcCurrentInFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, encountered by the HDLC interface in the current 15 minute interval." ::= { hdlcCurrentEntry 4 } hdlcCurrentInErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored received frames, encountered by the HDLC interface in the current 15 minute interval." ::= { hdlcCurrentEntry 5 } hdlcCurrentOutFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames, encountered by the HDLC interface in the current 15 minute interval." ::= { hdlcCurrentEntry 6 } hdlcCurrentAbortedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of frames, in which at least seven consecutive '1'-s (Abort sequence) were encountered by the HDLC interface in the current 15 minute interval." ::= { hdlcCurrentEntry 7 } hdlcCurrentLengthError OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with length error, encountered by the HDLC interface in the current 15 minute interval." ::= { hdlcCurrentEntry 8 } --Interval Table hdlcIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF HdlcIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The HDLC Interval table." ::= { hdlcPerformance 2 } hdlcIntervalEntry OBJECT-TYPE SYNTAX HdlcIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the HDLC Interval table." INDEX { hdlcIntervalIfIndex, hdlcIntervalNumber } ::= { hdlcIntervalTable 1 } HdlcIntervalEntry ::= SEQUENCE { hdlcIntervalIfIndex Integer32, hdlcIntervalNumber Integer32, hdlcIntervalStatus OCTET STRING, hdlcIntervalLOF Gauge32, hdlcIntervalInFrames Gauge32, hdlcIntervalInErrors Gauge32, hdlcIntervalOutFrames Gauge32, hdlcIntervalAbortedFrames Gauge32, hdlcIntervalLengthError Gauge32 } hdlcIntervalIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the HDLC interface. It may be ifIndex." ::= { hdlcIntervalEntry 1 } hdlcIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist)." ::= { hdlcIntervalEntry 2 } hdlcIntervalStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { hdlcIntervalEntry 3 } hdlcIntervalLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of seconds the port is in Loss Of Frame state, encountered by an HDLC interface in one of the previous 96, individual 15 minute, intervals." ::= { hdlcIntervalEntry 4 } hdlcIntervalInFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, encountered by the HDLC interface in one of the previous 96, individual 15 minute, intervals." ::= { hdlcIntervalEntry 5 } hdlcIntervalInErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored received frames, encountered by the HDLC interface in one of the previous 96, individual 15 minute, intervals." ::= { hdlcIntervalEntry 6 } hdlcIntervalOutFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames, encountered by the HDLC interface in one of the previous 96, individual 15 minute, intervals." ::= { hdlcIntervalEntry 7 } hdlcIntervalAbortedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of frames, in which at least seven consecutive '1'-s (Abort sequence) were encountered by the HDLC interface in one of the previous 96, individual 15 minute, intervals." ::= { hdlcIntervalEntry 8 } hdlcIntervalLengthError OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with length error, encountered by the HDLC interface in one of the previous 96, individual 15 minute, intervals." ::= { hdlcIntervalEntry 9 } -- -- file :v:\doc\rdv\mib\ver525\atm\ace101.txt -- -- -- file :v:\doc\rdv\mib\ver525\ATM\ace101.txt --RAD-ARC-MIB -- DEFINITIONS ::= BEGIN --Title: RAD-ACE MIB -- -- IMPORTS -- Gauge32, IpAddress FROM RFC1155-SMI -- ifIndex FROM IF-MIB -- OBJECT-TYPE FROM RFC-1212 -- TRAP-TYPE FROM RFC-1215 -- radAtm, agnLed, agnIndication FROM RAD-GEN-MIB -- RowStatus FROM SNMPv2-TC -- atmVplVpi, atmVclVpi, atmVclVci FROM ATM-MIB; -- RAD-ACE MIB --Title: RAD's ARC ATM PRODUCT MIB --Version: 1.0 --Date: 24.9.96 --By: Yair Arian --File: arc.mib -- --Last update: 19-Dec-2005 by Ilana Schvetz atmGen OBJECT IDENTIFIER ::= {radAtm 2} atmPerfHistory OBJECT IDENTIFIER ::= {atmGen 1} atmIfPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 1} -- aal5VccXTable ::= { atmIfPerformance 4 } in aal5.txt atmIfDataTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM interface Data table." ::= { atmIfPerformance 1 } atmIfDataEntry OBJECT-TYPE SYNTAX AtmIfDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM interface Data table." INDEX { ifIndex } ::= { atmIfDataTable 1 } AtmIfDataEntry ::= SEQUENCE { atmIfTimeElapsed Integer32, atmIfValidIntervals Integer32 } atmIfTimeElapsed OBJECT-TYPE SYNTAX Integer32 (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the near end current error- measurement period." ::= { atmIfDataEntry 1 } atmIfValidIntervals OBJECT-TYPE SYNTAX Integer32 (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online." ::= { atmIfDataEntry 2 } -- the ATM interface Current -- The ATM interface current table contains various statistics being -- collected for the current 15 minute interval. atmIfCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM interface Current table." ::= { atmIfPerformance 2 } atmIfCurrentEntry OBJECT-TYPE SYNTAX AtmIfCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM interface Current table." INDEX { ifIndex } ::= { atmIfCurrentTable 1 } AtmIfCurrentEntry ::= SEQUENCE { atmIfCurrentTxCells Gauge32, atmIfCurrentRxCells Gauge32, atmIfCurrentCorrectedHecs Gauge32, atmIfCurrentUncorrectedHecs Gauge32, atmIfCurrentHecErrorSeconds Gauge32 } atmIfCurrentTxCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted cells, encountered by an ATM interface in the current 15 minute interval." ::= { atmIfCurrentEntry 1 } atmIfCurrentRxCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received cells, encountered by an ATM interface in the current 15 minute interval." ::= { atmIfCurrentEntry 2 } atmIfCurrentCorrectedHecs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells with corrected HEC errors, encountered by an ATM interface in the current 15 minute interval." ::= { atmIfCurrentEntry 3 } atmIfCurrentUncorrectedHecs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells with uncorrected HEC errors, encountered by an ATM interface in the current 15 minute interval." ::= { atmIfCurrentEntry 4 } atmIfCurrentHecErrorSeconds OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of seconds with HEC errors, encountered by an ATM interface in the current 15 minute interval." ::= { atmIfCurrentEntry 5 } -- the ATM interface Interval -- The ATM interface Interval Table contains various statistics -- collected by each ATM Interface over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. atmIfIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM interface Interval table." ::= { atmIfPerformance 3 } atmIfIntervalEntry OBJECT-TYPE SYNTAX AtmIfIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM interface Interval table." INDEX { ifIndex, atmIfIntervalNumber } ::= { atmIfIntervalTable 1 } AtmIfIntervalEntry ::= SEQUENCE { atmIfIntervalNumber Integer32, atmIfIntervalTxCells Gauge32, atmIfIntervalRxCells Gauge32, atmIfIntervalCorrectedHecs Gauge32, atmIfIntervalUncorrectedHecs Gauge32, atmIfIntervalHecErrorSeconds Gauge32 } atmIfIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { atmIfIntervalEntry 1 } atmIfIntervalTxCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted cells , encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals." ::= { atmIfIntervalEntry 2 } atmIfIntervalRxCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received cells, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals." ::= { atmIfIntervalEntry 3 } atmIfIntervalCorrectedHecs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells with corrected HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals." ::= { atmIfIntervalEntry 4 } atmIfIntervalUncorrectedHecs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells with uncorrected HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals." ::= { atmIfIntervalEntry 5 } atmIfIntervalHecErrorSeconds OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of seconds with HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals." ::= { atmIfIntervalEntry 6 } atmPvcPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 2} atmVpPerformance OBJECT IDENTIFIER ::= {atmPvcPerformance 1} -- the ATM VP Current -- The ATM VP current table contains various statistics being -- collected for the current 15 minute interval. atmVpCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VP Current table." ::= { atmVpPerformance 1 } atmVpCurrentEntry OBJECT-TYPE SYNTAX AtmVpCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VP Current table." INDEX { ifIndex, atmVpCurrentVpi } ::= { atmVpCurrentTable 1 } AtmVpCurrentEntry ::= SEQUENCE { atmVpCurrentVpi Integer32, atmVpCurrentRxCellsClp01 Gauge32, atmVpCurrentRxCellsClp0 Gauge32, atmVpCurrentGcra0Violations Gauge32, atmVpCurrentGcra1Violations Gauge32, atmVpCurrentRxAIS Gauge32, atmVpCurrentTxAIS Gauge32, atmVpCurrentRxRDI Gauge32, atmVpCurrentTxRDI Gauge32, atmVpCurrentContinuityLoss Gauge32, atmVpCurrentUAS Gauge32, atmVpCurrentSES Gauge32, atmVpCurrentCDC Gauge32, atmVpCurrentTotalDiscards Gauge32, atmVpCurrentClp0Discards Gauge32, atmVpCurrentTotalCellOuts Gauge32, atmVpCurrentClp0CellOuts Gauge32, atmVpCurrentTaggedOuts Gauge32, atmVpCurrentPCR Gauge32, atmVpCurrentSCR Gauge32, atmVpCurrentMCR Gauge32, atmVpCurrentShaperTotalDiscards Gauge32, atmVpCurrentShaperClp0Discards Gauge32, atmVpCurrentShaperClp1Discards Gauge32 } atmVpCurrentVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VPL." ::= { atmVpCurrentEntry 1 } atmVpCurrentRxCellsClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 2 } atmVpCurrentRxCellsClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 3 } atmVpCurrentGcra0Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA0, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 4 } atmVpCurrentGcra1Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA1, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 5 } atmVpCurrentRxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received AIS cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 6 } atmVpCurrentTxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted AIS cells, encountered by the VPL of this ATM interface in the current 15 minute interval. Not Supported in the first phase." ::= { atmVpCurrentEntry 7 } atmVpCurrentRxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received RDI cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 8 } atmVpCurrentTxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted RDI cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 9 } atmVpCurrentContinuityLoss OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of loss of continuity cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 10 } atmVpCurrentUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 11 } atmVpCurrentSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severerly Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 12 } atmVpCurrentCDC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Amount of cells dropped in the current 15 minute interval of the VP connection." ::= { atmVpCurrentEntry 13 } atmVpCurrentTotalDiscards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1." ::= { atmVpCurrentEntry 14 } atmVpCurrentClp0Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells received with CLP=0 and discarded by the traffic policing entity." ::= { atmVpCurrentEntry 15 } atmVpCurrentTotalCellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells." ::= { atmVpCurrentEntry 16 } atmVpCurrentClp0CellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted with CLP=0 by this VPL." ::= { atmVpCurrentEntry 17 } atmVpCurrentTaggedOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL." ::= { atmVpCurrentEntry 18 } atmVpCurrentPCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum traffic rate encountered in the last interval of the VP connection (monitored once a second)." ::= { atmVpCurrentEntry 19 } atmVpCurrentSCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average traffic rate during the last interval of the VP connection." ::= { atmVpCurrentEntry 20 } atmVpCurrentMCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "MCR - The minimum traffic rate encountered in the last interval of the VP connection (monitored once a second)." ::= { atmVpCurrentEntry 21 } atmVpCurrentShaperTotalDiscards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper." ::= { atmVpCurrentEntry 22 } atmVpCurrentShaperClp0Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of CLP0 cells discarded due to congestion by the traffic shaper." ::= { atmVpCurrentEntry 23 } atmVpCurrentShaperClp1Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of CLP1 cells discarded due to congestion by the traffic shaper." ::= { atmVpCurrentEntry 24 } -- The ATM VP current table for Performance Management -- which contains various statistics being -- collected for the current 15 minute interval. atmVpPMCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpPMCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VP Current table for Performance Management." ::= { atmVpPerformance 2 } atmVpPMCurrentEntry OBJECT-TYPE SYNTAX AtmVpPMCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VP Current table for Performance Management." INDEX { ifIndex, atmVpPMCurrentVpi, atmVpPMCurrentDir } ::= { atmVpPMCurrentTable 1 } AtmVpPMCurrentEntry ::= SEQUENCE { atmVpPMCurrentDir INTEGER, atmVpPMCurrentVpi Integer32, atmVpPMCurrentTxClp01 Gauge32, atmVpPMCurrentTxClp0 Gauge32, atmVpPMCurrentRxClp01 Gauge32, atmVpPMCurrentRxClp0 Gauge32, atmVpPMCurrentErroredCells Gauge32, atmVpPMCurrentLostCells Gauge32, atmVpPMCurrentMisinsertedCells Gauge32, atmVpPMCurrentECB Gauge32, atmVpPMCurrentSECB Gauge32, atmVpPMCurrentES Gauge32, atmVpPMCurrentSES Gauge32, atmVpPMCurrentUAS Gauge32, atmVpPMCurrentIntervalQuality INTEGER, atmVpPMCurrentLastDayQuality INTEGER } atmVpPMCurrentVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VPL." ::= { atmVpPMCurrentEntry 1 } atmVpPMCurrentDir OBJECT-TYPE SYNTAX INTEGER {forward(2), backward(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The direction of performance management." ::= { atmVpPMCurrentEntry 2 } atmVpPMCurrentTxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0+1 cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 3 } atmVpPMCurrentTxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0 cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 4 } atmVpPMCurrentRxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0+1 cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 5 } atmVpPMCurrentRxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0 cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 6 } atmVpPMCurrentErroredCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of errored cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 7 } atmVpPMCurrentLostCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of lost cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 8 } atmVpPMCurrentMisinsertedCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of misinserted cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 9 } atmVpPMCurrentECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of ECB, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 10 } atmVpPMCurrentSECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SECB, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 11 } atmVpPMCurrentES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 12 } atmVpPMCurrentSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 13 } atmVpPMCurrentUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 14 } atmVpPMCurrentIntervalQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), unacceptable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable." DEFVAL { normal } ::= { atmVpPMCurrentEntry 15 } atmVpPMCurrentLastDayQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), degraded(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded." DEFVAL { normal } ::= { atmVpPMCurrentEntry 16 } -- the ATM VP Interval -- The ATM VP Interval Table contains various statistics -- collected by each ATM Interface/VP over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. atmVpIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM Vp Interval table." ::= { atmVpPerformance 3 } atmVpIntervalEntry OBJECT-TYPE SYNTAX AtmVpIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM Vp Interval table." INDEX { ifIndex, atmVpIntervalVpi, atmVpIntervalNumber } ::= { atmVpIntervalTable 1 } AtmVpIntervalEntry ::= SEQUENCE { atmVpIntervalVpi Integer32, atmVpIntervalNumber Integer32, atmVpIntervalRxCellsClp01 Gauge32, atmVpIntervalRxCellsClp0 Gauge32, atmVpIntervalGcra0Violations Gauge32, atmVpIntervalGcra1Violations Gauge32, atmVpIntervalRxAIS Gauge32, atmVpIntervalTxAIS Gauge32, atmVpIntervalRxRDI Gauge32, atmVpIntervalTxRDI Gauge32, atmVpIntervalContinuityLoss Gauge32, atmVpIntervalUAS Gauge32, atmVpIntervalSES Gauge32, atmVpIntervalCDC Gauge32, atmVpIntervalTotalDiscards Gauge32, atmVpIntervalClp0Discards Gauge32, atmVpIntervalTotalCellOuts Gauge32, atmVpIntervalClp0CellOuts Gauge32, atmVpIntervalTaggedOuts Gauge32, atmVpIntervalPCR Gauge32, atmVpIntervalSCR Gauge32, atmVpIntervalMCR Gauge32, atmVpIntervalShaperTotalDiscards Gauge32, atmVpIntervalShaperClp0Discards Gauge32, atmVpIntervalShaperClp1Discards Gauge32 } atmVpIntervalVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VPL." ::= { atmVpIntervalEntry 1 } atmVpIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { atmVpIntervalEntry 2 } atmVpIntervalRxCellsClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted cells , encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 3 } atmVpIntervalRxCellsClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 4 } atmVpIntervalGcra0Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA0, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 5 } atmVpIntervalGcra1Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA1, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 6 } atmVpIntervalRxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received AIS cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 7 } atmVpIntervalTxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted AIS cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals. Not supported in the first phase." ::= { atmVpIntervalEntry 8 } atmVpIntervalRxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received RDI cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 9 } atmVpIntervalTxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted RDI cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 10 } atmVpIntervalContinuityLoss OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Continuity Loss cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 11 } atmVpIntervalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 12 } atmVpIntervalSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severerly Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 13 } atmVpIntervalCDC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Amount of cells dropped in the 15 minute interval of the VP connection." ::= { atmVpIntervalEntry 14 } atmVpIntervalTotalDiscards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1." ::= { atmVpIntervalEntry 15 } atmVpIntervalClp0Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity." ::= { atmVpIntervalEntry 16 } atmVpIntervalTotalCellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells." ::= { atmVpIntervalEntry 17 } atmVpIntervalClp0CellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted with CLP=0 by this VPL." ::= { atmVpIntervalEntry 18 } atmVpIntervalTaggedOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL." ::= { atmVpIntervalEntry 19 } atmVpIntervalPCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum traffic rate encountered in the last interval of the VP connection (monitored once a second) encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 20 } atmVpIntervalSCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average traffic rate during the last interval of the VP connection , encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 21 } atmVpIntervalMCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "MCR - The minimum traffic rate encountered in the last interval of the VP connection (monitored once a second) encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 22 } atmVpIntervalShaperTotalDiscards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper." ::= { atmVpIntervalEntry 23 } atmVpIntervalShaperClp0Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of CLP0 cells discarded due to congestion by the traffic shaper." ::= { atmVpIntervalEntry 24 } atmVpIntervalShaperClp1Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of CLP1 cells discarded due to congestion by the traffic shaper." ::= { atmVpIntervalEntry 25 } -- The ATM VP Interval Table for Performance Management -- contains various statistics -- collected by each ATM Interface/VP over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. atmVpPMIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpPMIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM Vp Interval table for Performance Management." ::= { atmVpPerformance 4 } atmVpPMIntervalEntry OBJECT-TYPE SYNTAX AtmVpPMIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM Vp Interval table for Performance Management." INDEX { ifIndex, atmVpPMIntervalVpi, atmVpPMIntervalDir, atmVpPMIntervalNumber } ::= { atmVpPMIntervalTable 1 } AtmVpPMIntervalEntry ::= SEQUENCE { atmVpPMIntervalVpi Integer32, atmVpPMIntervalDir INTEGER, atmVpPMIntervalNumber Integer32, atmVpPMIntervalTxClp01 Gauge32, atmVpPMIntervalTxClp0 Gauge32, atmVpPMIntervalRxClp01 Gauge32, atmVpPMIntervalRxClp0 Gauge32, atmVpPMIntervalErroredCells Gauge32, atmVpPMIntervalLostCells Gauge32, atmVpPMIntervalMisinsertedCells Gauge32, atmVpPMIntervalECB Gauge32, atmVpPMIntervalSECB Gauge32, atmVpPMIntervalES Gauge32, atmVpPMIntervalSES Gauge32, atmVpPMIntervalUAS Gauge32, atmVpPMIntervalQuality INTEGER, atmVpPMIntervalLastDayQuality INTEGER } atmVpPMIntervalVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VPL." ::= { atmVpPMIntervalEntry 1 } atmVpPMIntervalDir OBJECT-TYPE SYNTAX INTEGER {forward(2), backward(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The direction of performance management." ::= { atmVpPMIntervalEntry 2 } atmVpPMIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { atmVpPMIntervalEntry 3 } atmVpPMIntervalTxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0+1 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 4 } atmVpPMIntervalTxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 5 } atmVpPMIntervalRxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0+1 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 6 } atmVpPMIntervalRxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 7 } atmVpPMIntervalErroredCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 8 } atmVpPMIntervalLostCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Lost cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 9 } atmVpPMIntervalMisinsertedCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Misinserted cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 10 } atmVpPMIntervalECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of ECBs encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 11 } atmVpPMIntervalSECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SECBs encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 12 } atmVpPMIntervalES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 13 } atmVpPMIntervalSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 14 } atmVpPMIntervalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 15 } atmVpPMIntervalQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), unacceptable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable." DEFVAL { normal } ::= { atmVpPMIntervalEntry 16} atmVpPMIntervalLastDayQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), degraded(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded." DEFVAL { normal } ::= { atmVpPMIntervalEntry 17} -- VP QoS Table atmVpQoSTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The VP QoS table." ::= { atmVpPerformance 5 } atmVpQoSEntry OBJECT-TYPE SYNTAX AtmVpQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { ifIndex, atmVplVpi, atmVpQoSPeriodRef } ::= { atmVpQoSTable 1 } AtmVpQoSEntry ::= SEQUENCE { atmVpQoSPeriodRef INTEGER, atmVpQoSElapsedTime Integer32, atmVpQoSUAS Gauge32 } atmVpQoSPeriodRef OBJECT-TYPE SYNTAX INTEGER { currentPeriod (1), lastPeriod (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index that specifies which period of time, the next 2 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0." ::= { atmVpQoSEntry 1 } atmVpQoSElapsedTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Elapsed Time in seconds. - for atmVpQoSPeriodRef = currentPeriod: The period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. - for atmVpQoSPeriodRef = lastPeriod: The value of atmVpQoSElapsedTime when last systemResetAllStatsCmd was received." ::= { atmVpQoSEntry 2 } atmVpQoSUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Unavailable Seconds for the reference period (atmVpQoSPeriodRef)." ::= { atmVpQoSEntry 3 } -- VP PM QoS Table atmVpPMQoSTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpPMQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The PM VP QoS table." ::= { atmVpPerformance 6 } atmVpPMQoSEntry OBJECT-TYPE SYNTAX AtmVpPMQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { ifIndex, atmVplVpi, atmVpPMQoSDirection ,atmVpPMQoSPeriodRef } ::= { atmVpPMQoSTable 1 } AtmVpPMQoSEntry ::= SEQUENCE { atmVpPMQoSDirection INTEGER, atmVpPMQoSPeriodRef INTEGER, atmVpPMQoSCLR Gauge32, atmVpPMQoSCER Gauge32, atmVpPMQoSCMR Gauge32 } atmVpPMQoSDirection OBJECT-TYPE SYNTAX INTEGER { forward (2), backward (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The direction of performance management." ::= { atmVpPMQoSEntry 1 } atmVpPMQoSPeriodRef OBJECT-TYPE SYNTAX INTEGER { currentPeriod (1), lastPeriod (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0." ::= { atmVpPMQoSEntry 2 } atmVpPMQoSCLR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Loss Ratio counter for the reference period (atmVpPMQoSPeriodRef)- defined in accordance with I.356 , in %. The value will be multipuled by 100." ::= { atmVpPMQoSEntry 3 } atmVpPMQoSCER OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Error Ratio counter for the reference period (atmVpPMQoSPeriodRef) defined in accordance with I.356 , in %. The value will be multipuled by 100." ::= { atmVpPMQoSEntry 4 } atmVpPMQoSCMR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Misinsertion Ratio counter for the reference period (atmVpPMQoSPeriodRef) defined in accordance with I.356 , cells/sec ." ::= { atmVpPMQoSEntry 5 } --VP Shaper Statistics Table atmVpShaperStatTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpShaperStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VP shaper statistics table." ::= { atmVpPerformance 7 } atmVpShaperStatEntry OBJECT-TYPE SYNTAX AtmVpShaperStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VP shaper statistics table." INDEX { ifIndex, atmVplVpi } ::= { atmVpShaperStatTable 1 } AtmVpShaperStatEntry ::= SEQUENCE { atmVpShaperDiscarded Counter32, atmVpShaperOccupation Integer32, atmVpShaperMaxOccupation Integer32, atmVpShaperLevel INTEGER, atmVpShaperEpdDropped Counter32, atmVpShaperTotalEpdDropped Counter32 } atmVpShaperDiscarded OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Cells that were discarded in the shaper on that VPC due to buffer overflow. This counter counts till it reaches its MAX value (20 bits) and then rolls over." ::= { atmVpShaperStatEntry 1 } atmVpShaperOccupation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Cells that are currently stored in the buffer. This parameter is limited to 20 bits." ::= { atmVpShaperStatEntry 2} atmVpShaperMaxOccupation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Maximum number of Cells that were stored in the buffer, since this VP was activated. This parameter is limited to 20 bits." ::= { atmVpShaperStatEntry 3} atmVpShaperLevel OBJECT-TYPE SYNTAX INTEGER { empty (1), full (2), below (3), above (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The occupation of the buffer according to a predefined threshold. empty - buffer is Empty full - buffer is Full below - buffer is Below the threshold above - buffer is Above the threshold. This is also the trigger to start EPD\PPD mechanism, if set for the VPC." ::= { atmVpShaperStatEntry 4} atmVpShaperEpdDropped OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last second. This parameter is limited to 24 bits. Applicable for a EPD/PPD VP only." ::= { atmVpShaperStatEntry 5} atmVpShaperTotalEpdDropped OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Total number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last 15 minutes. This counter automatically reset itself every 15 minutes. Applicable for a EPD/PPD VP only." ::= { atmVpShaperStatEntry 6} atmVcPerformance OBJECT IDENTIFIER ::= {atmPvcPerformance 2} -- the ATM VC Current -- The ATM VC current table contains various statistics being -- collected for the current 15 minute interval. atmVcCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VC Current table." ::= { atmVcPerformance 1 } atmVcCurrentEntry OBJECT-TYPE SYNTAX AtmVcCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VC Current table." INDEX { ifIndex, atmVcCurrentVpi, atmVcCurrentVci } ::= { atmVcCurrentTable 1 } AtmVcCurrentEntry ::= SEQUENCE { atmVcCurrentVpi Integer32, atmVcCurrentVci Integer32, atmVcCurrentRxCellsClp01 Gauge32, atmVcCurrentRxCellsClp0 Gauge32, atmVcCurrentGcra0Violations Gauge32, atmVcCurrentGcra1Violations Gauge32, atmVcCurrentRxAIS Gauge32, atmVcCurrentTxAIS Gauge32, atmVcCurrentRxRDI Gauge32, atmVcCurrentTxRDI Gauge32, atmVcCurrentContinuityLoss Gauge32, atmVcCurrentUAS Gauge32, atmVcCurrentSES Gauge32, atmVcCurrentCDC Gauge32, atmVcCurrentTotalDiscards Gauge32, atmVcCurrentClp0Discards Gauge32, atmVcCurrentTotalCellOuts Gauge32, atmVcCurrentClp0CellOuts Gauge32, atmVcCurrentTaggedOuts Gauge32, atmVcCurrentPCR Gauge32, atmVcCurrentSCR Gauge32, atmVcCurrentMCR Gauge32, atmVcCurrentShaperTotalDiscards Gauge32, atmVcCurrentShaperClp0Discards Gauge32, atmVcCurrentShaperClp1Discards Gauge32 } atmVcCurrentVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VCL." ::= { atmVcCurrentEntry 1 } atmVcCurrentVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the VCL." ::= { atmVcCurrentEntry 2 } atmVcCurrentRxCellsClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 3 } atmVcCurrentRxCellsClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 4 } atmVcCurrentGcra0Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA0, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 5 } atmVcCurrentGcra1Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA1, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 6 } atmVcCurrentRxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received AIS cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 7 } atmVcCurrentTxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted AIS cells, encountered by the VCL of this ATM interface in the current 15 minute interval. Not Supported in the first phase." ::= { atmVcCurrentEntry 8 } atmVcCurrentRxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received RDI cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 9 } atmVcCurrentTxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted RDI cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 10 } atmVcCurrentContinuityLoss OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of loss of continuity cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 11 } atmVcCurrentUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 12 } atmVcCurrentSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severerly Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 13 } atmVcCurrentCDC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Amount of cells dropped in the current 15 minute interval of the VC connection." ::= { atmVcCurrentEntry 14 } atmVcCurrentTotalDiscards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1." ::= { atmVcCurrentEntry 15 } atmVcCurrentClp0Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity." ::= { atmVcCurrentEntry 16 } atmVcCurrentTotalCellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells." ::= { atmVcCurrentEntry 17 } atmVcCurrentClp0CellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted with CLP=0 by this VPL." ::= { atmVcCurrentEntry 18 } atmVcCurrentTaggedOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL." ::= { atmVcCurrentEntry 19 } atmVcCurrentPCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum traffic rate encountered in the last interval of the VC connection (monitored once a second)." ::= { atmVcCurrentEntry 20 } atmVcCurrentSCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average traffic rate during the last interval of the VC connection." ::= { atmVcCurrentEntry 21 } atmVcCurrentMCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "MCR - The minimum traffic rate encountered in the last interval of the VC connection (monitored once a second)." ::= { atmVcCurrentEntry 22 } atmVcCurrentShaperTotalDiscards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper." ::= { atmVcCurrentEntry 23 } atmVcCurrentShaperClp0Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of CLP0 cells discarded due to congestion by the traffic shaper." ::= { atmVcCurrentEntry 24 } atmVcCurrentShaperClp1Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of CLP1 cells discarded due to congestion by the traffic shaper." ::= { atmVcCurrentEntry 25 } -- The ATM VC current table for Performance Management -- which contains various statistics being -- collected for the current 15 minute interval. atmVcPMCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcPMCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VC Current table for Performance Management." ::= { atmVcPerformance 2 } atmVcPMCurrentEntry OBJECT-TYPE SYNTAX AtmVcPMCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VC Current table for Performance Management." INDEX { ifIndex, atmVcPMCurrentVpi, atmVcPMCurrentVci, atmVcPMCurrentDir } ::= { atmVcPMCurrentTable 1 } AtmVcPMCurrentEntry ::= SEQUENCE { atmVcPMCurrentVpi Integer32, atmVcPMCurrentVci Integer32, atmVcPMCurrentDir Integer32, atmVcPMCurrentTxClp01 Gauge32, atmVcPMCurrentTxClp0 Gauge32, atmVcPMCurrentRxClp01 Gauge32, atmVcPMCurrentRxClp0 Gauge32, atmVcPMCurrentErroredCells Gauge32, atmVcPMCurrentLostCells Gauge32, atmVcPMCurrentMisinsertedCells Gauge32, atmVcPMCurrentECB Gauge32, atmVcPMCurrentSECB Gauge32, atmVcPMCurrentES Gauge32, atmVcPMCurrentSES Gauge32, atmVcPMCurrentUAS Gauge32, atmVcPMCurrentIntervalQuality INTEGER, atmVcPMCurrentLastDayQuality INTEGER } atmVcPMCurrentVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VCL." ::= { atmVcPMCurrentEntry 1 } atmVcPMCurrentVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the VCL." ::= { atmVcPMCurrentEntry 2 } atmVcPMCurrentDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The direction of Performance Management." ::= { atmVcPMCurrentEntry 3 } atmVcPMCurrentTxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0+1 cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 4 } atmVcPMCurrentTxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0 cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 5 } atmVcPMCurrentRxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0+1 cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 6 } atmVcPMCurrentRxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0 cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 7 } atmVcPMCurrentErroredCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of errored cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 8 } atmVcPMCurrentLostCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of lost cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 9 } atmVcPMCurrentMisinsertedCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of misinserted cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 10 } atmVcPMCurrentECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of ECBs encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 11 } atmVcPMCurrentSECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SECBs encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 12 } atmVcPMCurrentES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 13 } atmVcPMCurrentSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 14 } atmVcPMCurrentUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 15 } atmVcPMCurrentIntervalQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), unacceptable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable." DEFVAL { normal } ::= { atmVcPMCurrentEntry 16 } atmVcPMCurrentLastDayQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), degraded(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded." DEFVAL { normal } ::= { atmVcPMCurrentEntry 17 } -- the ATM VC Interval -- The ATM VC Interval Table contains various statistics -- collected by each ATM Interface/VC over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. atmVcIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM Vc Interval table." ::= { atmVcPerformance 3 } atmVcIntervalEntry OBJECT-TYPE SYNTAX AtmVcIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM Vc Interval table." INDEX { ifIndex, atmVcIntervalVpi, atmVcIntervalVci, atmVcIntervalNumber } ::= { atmVcIntervalTable 1 } AtmVcIntervalEntry ::= SEQUENCE { atmVcIntervalVpi Integer32, atmVcIntervalVci Integer32, atmVcIntervalNumber Integer32, atmVcIntervalRxCellsClp01 Gauge32, atmVcIntervalRxCellsClp0 Gauge32, atmVcIntervalGcra0Violations Gauge32, atmVcIntervalGcra1Violations Gauge32, atmVcIntervalRxAIS Gauge32, atmVcIntervalTxAIS Gauge32, atmVcIntervalRxRDI Gauge32, atmVcIntervalTxRDI Gauge32, atmVcIntervalContinuityLoss Gauge32, atmVcIntervalUAS Gauge32, atmVcIntervalSES Gauge32, atmVcIntervalCDC Gauge32, atmVcIntervalTotalDiscards Gauge32, atmVcIntervalClp0Discards Gauge32, atmVcIntervalTotalCellOuts Gauge32, atmVcIntervalClp0CellOuts Gauge32, atmVcIntervalTaggedOuts Gauge32, atmVcIntervalPCR Gauge32, atmVcIntervalSCR Gauge32, atmVcIntervalMCR Gauge32, atmVcIntervalShaperTotalDiscards Gauge32, atmVcIntervalShaperClp0Discards Gauge32, atmVcIntervalShaperClp1Discards Gauge32 } atmVcIntervalVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VCL." ::= { atmVcIntervalEntry 1 } atmVcIntervalVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the VCL." ::= { atmVcIntervalEntry 2 } atmVcIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { atmVcIntervalEntry 3 } atmVcIntervalRxCellsClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted cells , encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 4 } atmVcIntervalRxCellsClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 5 } atmVcIntervalGcra0Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA0, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 6 } atmVcIntervalGcra1Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA1, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 7 } atmVcIntervalRxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received AIS cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 8 } atmVcIntervalTxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted AIS cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals. Not supported in the first phase." ::= { atmVcIntervalEntry 9 } atmVcIntervalRxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received RDI cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 10 } atmVcIntervalTxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted RDI cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 11 } atmVcIntervalContinuityLoss OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Continuity Loss cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 12 } atmVcIntervalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 13 } atmVcIntervalSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severerly Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 14 } atmVcIntervalCDC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Amount of cells dropped in the 15 minute interval of the VC connection." ::= { atmVcIntervalEntry 15 } atmVcIntervalTotalDiscards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1." ::= { atmVcIntervalEntry 16 } atmVcIntervalClp0Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity." ::= { atmVcIntervalEntry 17 } atmVcIntervalTotalCellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells." ::= { atmVcIntervalEntry 18 } atmVcIntervalClp0CellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted with CLP=0 by this VPL." ::= { atmVcIntervalEntry 19 } atmVcIntervalTaggedOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL." ::= { atmVcIntervalEntry 20 } atmVcIntervalPCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum traffic rate encountered in the last interval of the VC connection (monitored once a second) encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 21 } atmVcIntervalSCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average traffic rate during the last interval of the VC connection, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 22 } atmVcIntervalMCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "MCR - The minimum traffic rate encountered in the last interval of the VC connection (monitored once a second) encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 23 } atmVcIntervalShaperTotalDiscards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper." ::= { atmVcIntervalEntry 24 } atmVcIntervalShaperClp0Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of CLP0 cells discarded due to congestion by the traffic shaper." ::= { atmVcIntervalEntry 25 } atmVcIntervalShaperClp1Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of CLP1 cells discarded due to congestion by the traffic shaper." ::= { atmVcIntervalEntry 26 } -- The ATM VC Interval Table for Performance Management -- which contains various statistics -- collected by each ATM Interface/VC over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. atmVcPMIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcPMIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM Vc Interval table for Performance Management." ::= { atmVcPerformance 4 } --atmCESAAL1StatsTable OBJECT IDENTIFIER ::= {atmVcPerformance 5} (see hybCES.txt) atmVcPMIntervalEntry OBJECT-TYPE SYNTAX AtmVcPMIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM Vc Interval table for Performance Management." INDEX { ifIndex, atmVcPMIntervalVpi, atmVcPMIntervalVci, atmVcPMIntervalDir, atmVcPMIntervalNumber } ::= { atmVcPMIntervalTable 1 } AtmVcPMIntervalEntry ::= SEQUENCE { atmVcPMIntervalVpi Integer32, atmVcPMIntervalVci Integer32, atmVcPMIntervalDir INTEGER, atmVcPMIntervalNumber Integer32, atmVcPMIntervalTxClp01 Gauge32, atmVcPMIntervalTxClp0 Gauge32, atmVcPMIntervalRxClp01 Gauge32, atmVcPMIntervalRxClp0 Gauge32, atmVcPMIntervalErroredCells Gauge32, atmVcPMIntervalLostCells Gauge32, atmVcPMIntervalMisinsertedCells Gauge32, atmVcPMIntervalECB Gauge32, atmVcPMIntervalSECB Gauge32, atmVcPMIntervalES Gauge32, atmVcPMIntervalSES Gauge32, atmVcPMIntervalUAS Gauge32, atmVcPMIntervalQuality INTEGER, atmVcPMIntervalLastDayQuality INTEGER } atmVcPMIntervalVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VCL." ::= { atmVcPMIntervalEntry 1 } atmVcPMIntervalVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the VCL." ::= { atmVcPMIntervalEntry 2 } atmVcPMIntervalDir OBJECT-TYPE SYNTAX INTEGER {forward(2), backward(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The direction of Performance Management." ::= { atmVcPMIntervalEntry 3 } atmVcPMIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { atmVcPMIntervalEntry 4 } atmVcPMIntervalTxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0+1 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 5 } atmVcPMIntervalTxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 6 } atmVcPMIntervalRxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0+1 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 7 } atmVcPMIntervalRxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 8 } atmVcPMIntervalErroredCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 9 } atmVcPMIntervalLostCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Lost cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 10 } atmVcPMIntervalMisinsertedCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Misinserted cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 11 } atmVcPMIntervalECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of ECBs encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 12 } atmVcPMIntervalSECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SECBs encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 13 } atmVcPMIntervalES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 14 } atmVcPMIntervalSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 15 } atmVcPMIntervalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 16 } atmVcPMIntervalQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), unacceptable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable." DEFVAL { normal } ::= { atmVcPMIntervalEntry 17} atmVcPMIntervalLastDayQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), degraded(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded." DEFVAL { normal } ::= { atmVcPMIntervalEntry 18} -- VC QoS Table atmVcQoSTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VP QoS table." ::= { atmVcPerformance 6 } atmVcQoSEntry OBJECT-TYPE SYNTAX AtmVcQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VP table." INDEX { ifIndex, atmVclVpi, atmVclVci, atmVcQoSPeriodRef } ::= { atmVcQoSTable 1 } AtmVcQoSEntry ::= SEQUENCE { atmVcQoSPeriodRef INTEGER, atmVcQoSElapsedTime Integer32, atmVcQoSUAS Gauge32 } atmVcQoSPeriodRef OBJECT-TYPE SYNTAX INTEGER { currentPeriod (1), lastPeriod (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index that specifies which period of time, the next 2 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0." ::= { atmVcQoSEntry 1 } atmVcQoSElapsedTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Elapsed Time in seconds. - for atmVcQoSPeriodRef = currentPeriod: The period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. - for atmVcQoSPeriodRef = lastPeriod: The value of atmVcQoSElapsedTime when last systemResetAllStatsCmd was received." ::= { atmVcQoSEntry 2 } atmVcQoSUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Unavailable Seconds for the reference period (atmVcQoSPeriodRef)." ::= { atmVcQoSEntry 3 } -- VC PM QoS Table atmVcPMQoSTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcPMQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The PM VC QoS table." ::= { atmVcPerformance 7 } atmVcPMQoSEntry OBJECT-TYPE SYNTAX AtmVcPMQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the VC PM QoS table." INDEX { ifIndex, atmVclVpi, atmVclVci, atmVcPMQoSDirection ,atmVcPMQoSPeriodRef } ::= { atmVcPMQoSTable 1 } AtmVcPMQoSEntry ::= SEQUENCE { atmVcPMQoSDirection INTEGER, atmVcPMQoSPeriodRef INTEGER, atmVcPMQoSCLR Gauge32, atmVcPMQoSCER Gauge32, atmVcPMQoSCMR Gauge32 } atmVcPMQoSDirection OBJECT-TYPE SYNTAX INTEGER { forward(2), backward(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The direction of performance management." ::= { atmVcPMQoSEntry 1 } atmVcPMQoSPeriodRef OBJECT-TYPE SYNTAX INTEGER { currentPeriod (1), lastPeriod (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0." ::= { atmVcPMQoSEntry 2 } atmVcPMQoSCLR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Loss Ratio counter for the reference period (atmVcPMQoSPeriodRef)- defined in accordance with I.356 , in %. The value will be multipuled by 100." ::= { atmVcPMQoSEntry 3 } atmVcPMQoSCER OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Error Ratio counter for the reference period (atmVcPMQoSPeriodRef) defined in accordance with I.356 , in %. The value will be multipuled by 100." ::= { atmVcPMQoSEntry 4 } atmVcPMQoSCMR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Miss-insertion Ratio counter for the reference period (atmVcPMQoSPeriodRef) defined in accordance with I.356 , cells/sec ." ::= { atmVcPMQoSEntry 5 } --VC Shaper Statistics Table atmVcShaperStatTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcShaperStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VC shaper statistics table." ::= { atmVcPerformance 8 } atmVcShaperStatEntry OBJECT-TYPE SYNTAX AtmVcShaperStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VC shaper statistics table." INDEX { ifIndex, atmVclVpi, atmVclVci } ::= { atmVcShaperStatTable 1 } AtmVcShaperStatEntry ::= SEQUENCE { atmVcShaperDiscarded Counter32, atmVcShaperOccupation Integer32, atmVcShaperMaxOccupation Integer32, atmVcShaperLevel INTEGER, atmVcShaperEpdDropped Counter32, atmVcShaperTotalEpdDropped Counter32 } atmVcShaperDiscarded OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Cells that were discarded in the shaper on that VCC due to buffer overflow. This counter counts till it reaches its MAX value (20 bits) and then rolls over." ::= { atmVcShaperStatEntry 1 } atmVcShaperOccupation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Cells that are currently stored in the buffer. This parameter is limited to 20 bits." ::= { atmVcShaperStatEntry 2} atmVcShaperMaxOccupation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Maximum number of Cells that were stored in the buffer, since this VC was activated. This parameter is limited to 20 bits." ::= { atmVcShaperStatEntry 3} atmVcShaperLevel OBJECT-TYPE SYNTAX INTEGER { empty (1), full (2), below (3), above (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The occupation of the buffer according to a predefined threshold. empty - buffer is Empty full - buffer is Full below - buffer is Below the threshold above - buffer is Above the threshold. This is also the trigger to start EPD\PPD mechanism, if set for the VCC." ::= { atmVcShaperStatEntry 4} atmVcShaperEpdDropped OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Cells that were dropped in the shaper on that VCC due to EPD\PPD mechanism in the last second. This parameter is limited to 24 bits. Applicable for a EPD/PPD VC only." ::= { atmVcShaperStatEntry 5} atmVcShaperTotalEpdDropped OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Total number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last 15 minutes. This counter automatically reset itself every 15 minutes. Applicable for a EPD/PPD VC only." ::= { atmVcShaperStatEntry 6} -- New -- The agent will keep in this group the date & time corresponding to each interval. atmIntervalDateTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIntervalDateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The agent will keep in this group the date & time corresponding to each interval." ::= {atmPerfHistory 3} atmIntervalDateEntry OBJECT-TYPE SYNTAX AtmIntervalDateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The date & time for the given interval." INDEX { atmIntervalDateInterval } ::= { atmIntervalDateTable 1 } AtmIntervalDateEntry ::= SEQUENCE { atmIntervalDateInterval Integer32, atmIntervalDateDate DisplayString, atmIntervalDateTime DisplayString } atmIntervalDateInterval OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION " The interval number defining this entry." ::= { atmIntervalDateEntry 1} atmIntervalDateDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The date corresponding to this interval." ::= { atmIntervalDateEntry 2} atmIntervalDateTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The time corresponding to this interval." ::= { atmIntervalDateEntry 3} --atmNte OBJECT IDENTIFIER ::= {radAtm 3} atmNteSys OBJECT IDENTIFIER ::= {atmNte 1} atmNteSysConfig OBJECT IDENTIFIER ::= {atmNteSys 1} atmNteManagerTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteManagerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Manager Table includes all the NMSs that receive traps from this agent. A single manager can receive traps on more than one PVC. The agent will set implicitly the correct ifIndex, VPI, VCI values to all relevant entries in the table when the user changes them for one of the PVCs." ::= { atmNteSysConfig 1 } atmNteManagerEntry OBJECT-TYPE SYNTAX AtmNteManagerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A single manager and the PVC for receiving traps." INDEX { atmNteManagerIP, atmNteManagerPvc} ::= { atmNteManagerTable 1 } AtmNteManagerEntry ::= SEQUENCE { atmNteManagerIP IpAddress, atmNteManagerPvc Integer32, atmNteManagerIfIndex Integer32, atmNteManagerVpi Integer32, atmNteManagerVci Integer32, atmNteManagerTrapMask Integer32, atmNteManagerRowStatus RowStatus, atmNteManagerNextHop IpAddress, atmNteManagerVlanSupport INTEGER, atmNteManagerVlanIdentifier Integer32, atmNteManagerVlanFramePriority Integer32, atmNteManagerAlarmTrapMask OCTET STRING, atmNteManagerConfigPorts Integer32 } atmNteManagerIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the NMS." ::= { atmNteManagerEntry 1 } atmNteManagerPvc OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A PVC index. The range is 1..8. There are four PVCs on the User Port and four PVCs on the Network Port. The default VPI, VCI values are specified below." ::= { atmNteManagerEntry 2 } atmNteManagerIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The ATM interface index of the management port." ::= { atmNteManagerEntry 3 } atmNteManagerVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The VPI of the management VCL. Default: 0." ::= { atmNteManagerEntry 4 } atmNteManagerVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The VCI of the management VCL. Defaults: 32,33,34,35." ::= { atmNteManagerEntry 5 } atmNteManagerTrapMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this attribute determines the type of traps the agent should mask and not send to this NMS. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed." ::= { atmNteManagerEntry 6 } atmNteManagerRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= {atmNteManagerEntry 7} atmNteManagerNextHop OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter is relevant to Ethernet out of band host only (PVC=10). The Next Hop IP address of the entry route." ::= { atmNteManagerEntry 8 } atmNteManagerVlanSupport OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN support (Tagging). no - No support to VLAN. yes - 4 VLAN bytes will be added to the frame." ::= { atmNteManagerEntry 9} atmNteManagerVlanIdentifier OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN ID. Range is 0..4095." ::= { atmNteManagerEntry 10 } atmNteManagerVlanFramePriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN Frame priority.Range is 0..7." ::= { atmNteManagerEntry 11 } atmNteManagerAlarmTrapMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object determines the alarm traps that the agent should mask and not send to this NMS. The value is an Octet String, where each bit is assigned to a certain trap. If the bit = 1, the trap will be masked. If the bit = 0, the trap will not be masked. More details on the masked traps exist in the product specification. For products that do not mask specific traps, the value of the bits will be 0." ::= { atmNteManagerEntry 12 } atmNteManagerConfigPorts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This variable defines from which port/s this manager can configure the device. For IPmux 11 the value of this variable will be according to the ports combination: Network =1 User1=2 User2=4 (For Example: All ports = 7)." ::= { atmNteManagerEntry 13 } atmNteUPLTCR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Unacceptable ES Limit threshold for Performance Management." ::= {atmNteSysConfig 2} atmNteDPLTCR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Degraded ES Limit threshold for Performance Management." ::= {atmNteSysConfig 3} atmNteSysLogClearAll OBJECT-TYPE SYNTAX INTEGER { off(2), clear(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the variable to clear(3) removes all entries in the Log Buffer of the agent. The agent will immediately reset the variable to off(2)." ::= {atmNteSysConfig 4} atmNteUSESLTCR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Unacceptable SES Limit threshold for Performance Management." ::= {atmNteSysConfig 5} atmNteDSESLTCR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Degraded ES Limit threshold for Performance Management." ::= {atmNteSysConfig 6} atmNteProtection OBJECT IDENTIFIER ::= { atmNteSysConfig 8 } atmNteProtectionMode OBJECT-TYPE SYNTAX INTEGER { off (1), mspOn (2), pathOn (3), mspUniOn (4), mspOneToN (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Protection Mode. MspOn - Multiplex section protection. pathOn - High order path protection. mspUniOn - Multiplex section Uni-directional protection. mspOneToN - Multiplex section protection." ::= { atmNteProtection 1 } atmNteProtectionWorkingLink OBJECT-TYPE SYNTAX INTEGER { trunk1(2), trunk2(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the working link when atmNteProtectionMode is off." ::= { atmNteProtection 2 } atmNteProtectionSwitchLink OBJECT-TYPE SYNTAX INTEGER { off(1), forceSwitch(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "ForceSwitch - will force Switching from the working link to the backup link. Afterwards the agent will set atmNteProtectionSwitchLink back to off(1). atmNteProtectionMode must be either mspOn or pathOn." ::= { atmNteProtection 3 } atmNteConfOam OBJECT IDENTIFIER ::= { atmNteSysConfig 9 } atmNteConfOamSupport OBJECT-TYPE SYNTAX INTEGER { intermediate(1), segmentTermination(2), endToEndTermination(3), vpEndToEndVcSegment(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "OAM support mode, which determines the device location in a segment wise." ::= { atmNteConfOam 1 } atmNteConfOamTransmission OBJECT IDENTIFIER ::= { atmNteConfOam 2 } atmNteConfOamAIS OBJECT-TYPE SYNTAX INTEGER { none(1), user(2), network(3), both(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines if a F4 segment OAM cell is transmitted due to problems in the other port, i.e. physical layer alarm or F4 defect. This is valid only when the ACE101 has ATM UNI interfaces in both sides and is configured for 'Non-Intrusive' mode. none - AIS is not sent to any of the ports. user - F4 AIS will be sent toward the user when defect is detected in the network port. network - F4 AIS will be sent toward the network when defect is detected in the user port. both - F4 AIS will be sent toward the network when defect is detected in the user port and toward the user when defect is detected in the network port." ::= { atmNteConfOamTransmission 1 } atmNteConfOamRDI OBJECT-TYPE SYNTAX INTEGER { none(1), user(2), network(3), both(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines if an F4 OAM RDI cell is transmitted due to physical layer problems in the port (in addition to F4 RDI cells transmitted due to ATM layer problems). The type of F4 RDI (Segment or End-to-End) is according to the ACE-101 OAM mode. For example, If it is enabled for Network port, then physical layer defect will initiate the transmission of F4 RDI cell back to the trunk." ::= { atmNteConfOamTransmission 2 } atmNteConfOamAddressing OBJECT IDENTIFIER ::= { atmNteConfOam 3 } atmNteConfLoopbackAddMode OBJECT-TYPE SYNTAX INTEGER{ off(1), on(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Loopback addressing mode. on - will enable loopback addressing. off - will disable loopback addressing." ::= { atmNteConfOamAddressing 1 } atmNteConfLoopbackSourceAdd OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2..20)) MAX-ACCESS read-write STATUS current DESCRIPTION " Loopback source address. This field is relevant when atmNteConfOamAddMode is on." ::= { atmNteConfOamAddressing 2 } --OAM Table atmNteConfOamIfTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteConfOamIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "OAM support per ATM interface." ::= { atmNteConfOam 4 } atmNteConfOamIfEntry OBJECT-TYPE SYNTAX AtmNteConfOamIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { ifIndex } ::= { atmNteConfOamIfTable 1 } AtmNteConfOamIfEntry ::= SEQUENCE { atmNteConfOamIfAisRdi INTEGER } atmNteConfOamIfAisRdi OBJECT-TYPE SYNTAX INTEGER { off(1), on (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter controls the generation of F4/F5 AIS and RDI due to lower order problems such as physical layer problems. For AIS: Defines if F4/F5 AIS cell is transmitted due to problems such as physical layer alarm or F4/F5 defect. This is applicable for all ports . off - Problems in this port will not trigger F4/F5 AIS transmition to the ajacent port (e.g. from USER to NETWORK) of a VPC/VCC. on - Problems in this port will trigger F4/F5 AIS transmition to the ajacent port (e.g. from USER to NETWORK) of a VPC/VCC. For RDI: Defines if F4/F5 RDI cell will be transmitted due to physical layer problems in that port (in addition to F4/F5 RDI cells transmitted due to ATM layer problems). For example, If it is enabled for Network port, then physical layer defect will initiate the transmission of F4/F5 RDI cell back to the trunk. The type of F4/F5 (Segment or End-to-End) is according to the configuration of the VPC/VCC." ::= { atmNteConfOamIfEntry 1 } atmNteConfCAC OBJECT IDENTIFIER ::= { atmNteSysConfig 10 } atmNteConfCACMode OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "CAC support mode. For ACE2002, the following are the applicable values: disable(1), enable(2), 10 - 1000." ::= { atmNteConfCAC 1 } atmNteHostIfTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteHostIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Host IP interface table." ::= { atmNteSysConfig 11 } atmNteHostIfEntry OBJECT-TYPE SYNTAX AtmNteHostIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { atmNteHostPvcIndex } ::= { atmNteHostIfTable 1 } AtmNteHostIfEntry ::= SEQUENCE { atmNteHostPvcIndex Integer32, atmNteHostIP IpAddress, atmNteHostMask IpAddress, atmNteHostAtmIfIndex Integer32, atmNteHostVpi Integer32, atmNteHostVci Integer32, atmNteHostRowStatus RowStatus, atmNteHostRdnVpi Integer32, atmNteHostRdnVci Integer32, atmNteHostDefaultNextHop IpAddress, atmNteHostVlanTagging INTEGER, atmNteHostDefaultVlanID Integer32, atmNteHostDefaultVlanPriority Integer32 } atmNteHostPvcIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A PVC index. The range is 1..10." ::= { atmNteHostIfEntry 1 } atmNteHostIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The host interface IP address." ::= { atmNteHostIfEntry 2 } atmNteHostMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The host interface subnet mask." ::= { atmNteHostIfEntry 3 } atmNteHostAtmIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "ATM interface index. Will be 1 for user port, and 2 for network port." ::= { atmNteHostIfEntry 4 } atmNteHostVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "VPI of the PVC connected to that host interface." ::= { atmNteHostIfEntry 5 } atmNteHostVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "VCI of the PVC connected to that host interface." ::= { atmNteHostIfEntry 6 } atmNteHostRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= { atmNteHostIfEntry 7 } atmNteHostRdnVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The VPI of the redundant management VCL. This parameter is applicable only if atmNteRdnManagement=enable(3). " ::= { atmNteHostIfEntry 8 } atmNteHostRdnVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The VCI of the redundant management VCL. This parameter is applicable only if atmNteRdnManagement=enable(3). " ::= { atmNteHostIfEntry 9 } atmNteHostDefaultNextHop OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The host interface Default Next Hop address. This address will be used as default next hop for every Bundle mapped to this Host." ::= { atmNteHostIfEntry 10 } atmNteHostVlanTagging OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN Tag support. no - No support to VLAN. yes - 4 VLAN bytes will be added to each frame connected to this Host." ::= { atmNteHostIfEntry 11 } atmNteHostDefaultVlanID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Default VLAN ID of this Host." ::= { atmNteHostIfEntry 12 } atmNteHostDefaultVlanPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Default VLAN priority for this Host." ::= { atmNteHostIfEntry 13 } atmNteShaperMode OBJECT-TYPE SYNTAX INTEGER { normal (1), group (2), aggregate (3), vpInbandMng (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Shaper Mode. vpInbandMng - Vcc within a Vp for management." ::= { atmNteSysConfig 12 } atmNteOutputRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Aggregate shaping output rate in Cells per Seconds units. Default value is the Network port rate." ::= { atmNteSysConfig 13 } atmNteTosMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "TOS Mode." ::= { atmNteSysConfig 14 } atmNteTosMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter determines the seqence of bits that will be used for TOS. For ACE101 this parameter is applicable only if atmNteTosMode = enable. Valid only for IP-TOS process." ::= { atmNteSysConfig 15 } atmNteTosHighPriority OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-write STATUS current DESCRIPTION "Priorities options are High or Low. High priority will be represented by bit = 1. Low priority will be represented by bit = 0. Each TOS value will be represented by the bit location. For example, the string for TOS 2, 9, 15 with High priority, will be: |0000 0000|... ...|0000 0000|1000 0010|0000 0100| ...98 7654 3210 (Bit #) 8 ... 3 2 1 (Byte #)." ::= { atmNteSysConfig 16 } atmNtePlugAndPlayActivity OBJECT-TYPE SYNTAX INTEGER { disable (1), offline (2), online (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Activity control for Manager Plug And Play. disable - disable the feature. offline - Automatic learn IP address into offline memory. online - Automatic learn IP address into online memory. " ::= { atmNteSysConfig 17 } atmNteSlotUsage OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), user (2), network (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to ace2002. Slot 2 might be configured as user slot or as network slot." ::= { atmNteSysConfig 18 } atmNteConnectionsMaxNumber OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), max1024 (2), max2048 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The MAX number of connections supported by system. Setting this parameter will affect the number of MAX intervals supported. This parameter will affect the system only after reset. Changing this parameter from high value to a low value, will be accepted by agent only if the actual used connection <= the desired connection Max number. Applicable to ace2002. " ::= { atmNteSysConfig 19 } atmNteDefaultVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Default Vpi for management." ::= { atmNteSysConfig 20 } atmNteDefaultVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Default Vci for management." ::= { atmNteSysConfig 21 } atmNteReservedVpi OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Internal use VPI, where shaperMode=vpInbandMng." ::= { atmNteSysConfig 22 } atmNteRdnManagement OBJECT-TYPE SYNTAX INTEGER { disabled (2), enabled (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The redundancy management status." ::= { atmNteSysConfig 23 } atmNtePlugAndPlayIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-write STATUS current DESCRIPTION "The ifIndex of the Plug and Play VCC." ::= { atmNteSysConfig 24 } atmNteLoopbackTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Loopback state timeout in minutes. A value of zero means no timeout (for ever). Default is 5 min." ::= { atmNteSysConfig 25 } atmNteOamTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteOamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is a static table, which is created by agent once upon initialization. The created entries are actually, only the supported OAM features. This table enables addition of new features by adding new entries rather than adding scalar parameters. An OAM feature is defined by the indexes values combination." ::= { atmNteSysConfig 26 } atmNteOamEntry OBJECT-TYPE SYNTAX AtmNteOamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the OAM table. Each entry in this table will indicate a special OAM." INDEX {atmNteOamMode, atmNteOamCellType, atmNteOamLevel} ::= { atmNteOamTable 1 } AtmNteOamEntry ::= SEQUENCE { atmNteOamMode INTEGER, atmNteOamCellType INTEGER, atmNteOamLevel INTEGER, atmNteOamEnable INTEGER } atmNteOamMode OBJECT-TYPE SYNTAX INTEGER { endToEnd (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The OAM cell path. endToEnd(1) - the entire path." ::= { atmNteOamEntry 1 } atmNteOamCellType OBJECT-TYPE SYNTAX INTEGER { aisAndRdi (1), loopback (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique Indication Signal. aisAndRdi(1) - Alarm Indication Signal (AIS) and Remote Defect Indication (RDI) cell. loopback(2) - Loopback cell." ::= { atmNteOamEntry 2 } atmNteOamLevel OBJECT-TYPE SYNTAX INTEGER { -- f4 (2), f5 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The level of the OAM cell. -- f4 (2) - VP level, f5 (3) - VC level." ::= { atmNteOamEntry 3 } atmNteOamEnable OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter determines if the specified OAM cells will be enabled." ::= { atmNteOamEntry 4 } atmNteDefaultLoopbackThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Default OAM Loopback Failure Threshold value that will be used for configuration." ::= { atmNteSysConfig 27 } atmNteMaxBurstSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Maximum allowed burst size (cell units). This object is applicable for each Physical port." ::= { atmNteSysConfig 28 } atmNteGranularityFactor OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter affects the granularity of the guaranteed Rate (SCR+MCR) in spaced connection (cell/sec units). It is also defines the minimum guaranteed rate in spaced connection." ::= { atmNteSysConfig 29 } atmNteTotalInputRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the total input rate of the device in cells/sec." ::= { atmNteSysConfig 30 } atmNteTotalOutputRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the total output rate of the device in cells/sec." ::= { atmNteSysConfig 31 } atmAlarmForwardingTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmAlarmForwardingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Alarm Forwarding Mechanism will be operated for this table entries." ::= { atmNteSysConfig 32 } atmAlarmForwardingEntry OBJECT-TYPE SYNTAX AtmAlarmForwardingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table is a pair of ports that the Alarm Forwarding Mechanism is determined for." INDEX { atmAlarmForwardingFailPort, atmAlarmForwardingToPort } ::= { atmAlarmForwardingTable 1 } AtmAlarmForwardingEntry ::= SEQUENCE { atmAlarmForwardingFailPort Integer32, atmAlarmForwardingToPort Integer32, atmAlarmForwardingRowStatus RowStatus, atmAlarmForwardingFailureLevel BITS, atmAlarmForwardingRecoveryMode INTEGER, atmAlarmForwardingRecoveryCommand INTEGER, atmAlarmForwardingTimeFilterWindow Unsigned32 } atmAlarmForwardingFailPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Index of the port on which a fail occurs." ::= { atmAlarmForwardingEntry 1 } atmAlarmForwardingToPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Index of the port that will be affected upon the failure of the atmAlarmForwardingFailPort." ::= { atmAlarmForwardingEntry 2 } atmAlarmForwardingRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= { atmAlarmForwardingEntry 3 } atmAlarmForwardingFailureLevel OBJECT-TYPE SYNTAX BITS{ physical (0), atm (1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter determines the level of failure that will operate the Alarm Forwarding Mechanism." ::= { atmAlarmForwardingEntry 4 } atmAlarmForwardingRecoveryMode OBJECT-TYPE SYNTAX INTEGER { manual (1), automatic (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter determines the Recovery Mode. manual - The user should stop the RDI transmission by using the atmAlarmForwardingRecoveryCommand. automatic - The RDI transmission will be automatically stopped upon atmAlarmForwardingFailPort recovery." ::= { atmAlarmForwardingEntry 5 } atmAlarmForwardingRecoveryCommand OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter is a command. It is applicable when atmAlarmForwardingRecoveryMode = manual. on - Will stop the RDI transmission. After setting to 'On' the agent will set this parameter back to 'Off'." ::= { atmAlarmForwardingEntry 6 } atmAlarmForwardingTimeFilterWindow OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter determines the Time Filter Window, meaning: how much time (in seconds) should the alarm exist in order to start the Alarm Forwarding operation." ::= { atmAlarmForwardingEntry 7 } atmSysConfigCellTest OBJECT IDENTIFIER ::= { atmNteSysConfig 33 } atmSysConfigCellTestPort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-write STATUS current DESCRIPTION "An Index of the port on which the cell test will be sent." ::= { atmSysConfigCellTest 1 } atmSysConfigCellTestVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The VPI on which the cell test will be sent." ::= { atmSysConfigCellTest 2 } atmSysConfigCellTestVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The VCI on which the cell test will be sent." ::= { atmSysConfigCellTest 3 } atmSysConfigCellTestPti OBJECT-TYPE SYNTAX INTEGER { user (1), oamSegment (2), oamEndToEnd (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The cell type." ::= { atmSysConfigCellTest 4 } atmSysConfigCellTestClp OBJECT-TYPE SYNTAX INTEGER { clp0 (1), clp1 (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of the Cell." ::= { atmSysConfigCellTest 5 } atmSysConfigCellTestOamType OBJECT-TYPE SYNTAX INTEGER { ais (1), rdi (2), cc (3), lb (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The OAM type of the Cell. This object is applicable if atmSysConfigCellTestPti = oamSegment/oamEndToEnd ." ::= { atmSysConfigCellTest 6 } atmSysConfigCellTestPayload OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-write STATUS current DESCRIPTION "The payload of the cell. For OAM cell the payload is set automatically to 6A." ::= { atmSysConfigCellTest 7 } atmSysConfigCellTestQuantity OBJECT-TYPE SYNTAX Integer32 (1..10000) MAX-ACCESS read-write STATUS current DESCRIPTION "Quantity of cells to send." ::= { atmSysConfigCellTest 8 } atmSysConfigCellTestSendCmd OBJECT-TYPE SYNTAX INTEGER { off (2), send (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the variable to send(3) perfroms cell test. The agent will immediately reset the variable to off(2)." ::= { atmSysConfigCellTest 9 } -- The ATM VP Cross Connect Extension Table atmVpCrossConnectExtenTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpCrossConnectExtenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An extension to the ATM VP Cross Connect table (RFC2515 - atmVpCrossConnectTable)." ::= { atmNteSysConfig 34 } atmVpCrossConnectExtenEntry OBJECT-TYPE SYNTAX AtmVpCrossConnectExtenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table." AUGMENTS { atmVpCrossConnectEntry } ::= { atmVpCrossConnectExtenTable 1 } AtmVpCrossConnectExtenEntry ::= SEQUENCE { atmVpCrossConnectName SnmpAdminString } atmVpCrossConnectName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (1..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "The Connection's name." ::= { atmVpCrossConnectExtenEntry 1 } -- The ATM VC Cross Connect Extension Table atmVcCrossConnectExtenTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcCrossConnectExtenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An extension to the ATM VC Cross Connect table (RFC2515 - atmVcCrossConnectTable)." ::= { atmNteSysConfig 35 } atmVcCrossConnectExtenEntry OBJECT-TYPE SYNTAX AtmVcCrossConnectExtenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table." AUGMENTS { atmVcCrossConnectEntry } ::= { atmVcCrossConnectExtenTable 1 } AtmVcCrossConnectExtenEntry ::= SEQUENCE { atmVcCrossConnectName SnmpAdminString } atmVcCrossConnectName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (1..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "The Connection's name." ::= { atmVcCrossConnectExtenEntry 1 } -- The Congestion Thresholds Configuration Table atmCongestionThresholdTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmCongestionThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Congestion Thresholds Configuration Table." ::= { atmNteSysConfig 36 } atmCongestionThresholdEntry OBJECT-TYPE SYNTAX AtmCongestionThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table." INDEX { atmCongestionThresholdType, atmCongestionThresholdServiceCategory } ::= { atmCongestionThresholdTable 1 } AtmCongestionThresholdEntry ::= SEQUENCE { atmCongestionThresholdType INTEGER, atmCongestionThresholdServiceCategory INTEGER, atmCongestionThresholdValue Integer32 } atmCongestionThresholdType OBJECT-TYPE SYNTAX INTEGER { global (1), clp01 (2), clp1Upper (3), clp1Lower (4) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Congestion Threshold Type." ::= { atmCongestionThresholdEntry 1 } atmCongestionThresholdServiceCategory OBJECT-TYPE SYNTAX INTEGER { cbr (1), rtVbr (2), ubrPlus (3), ubr (4) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Congestion Threshold Service Category." ::= { atmCongestionThresholdEntry 2 } atmCongestionThresholdValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Congestion Threshold Value." ::= { atmCongestionThresholdEntry 3 } atmNteQosMode OBJECT-TYPE SYNTAX INTEGER { disable (1), multipleVc (2), singleVc (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the QoS Mode. disable(1) - QoS is disabled. multipleVc(2) - QoS is enabled and multiple VCs can be bound per bridge port. singleVc(3) - QoS is enabled and only single VC can be bound per bridge port." ::= { atmNteSysConfig 37 } atmNteSysInfo OBJECT IDENTIFIER ::= {atmNteSys 2} atmNteIdTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteIdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IDs of the cards and of the system." ::= { atmNteSysInfo 1 } atmNteIdEntry OBJECT-TYPE SYNTAX AtmNteIdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { atmNteIdIndex} ::= { atmNteIdTable 1 } AtmNteIdEntry ::= SEQUENCE { atmNteIdIndex Integer32, atmNteUnitId Integer32, atmNteUnitVersion DisplayString, atmNteCardType INTEGER, atmNteCardStatus INTEGER, atmNteCardCmd INTEGER, atmNteProgCardType INTEGER } atmNteIdIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An Index of the Unit ID table. The following units have IDs in this table: 1 - System 2 - ATM Board 3 - User Card 4 - Trunk 1 card 5 - Trunk 2 card 6 - Shaper 7 - Clock Unit 8 - Slot 1 card 9 - Slot 2 card 10 - Slot 3 card 11 - Slot 4 card 12 - Fan1 13 - Fan2 14 - Control Unit." ::= { atmNteIdEntry 1 } atmNteUnitId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the Unit. For index = 6, the id will describe the validity of a shaper in the system: 0 - Shaper Not exist 1 - Shaper exist. For index = 7, the id will describe the validity of a clock in the system: 0 - Clock Not exist 1 - Clock exist. 2- Clock exist but failed. For index = 12,13 the id will describe the functionality of a FAN1 : 0 - OK 1 - Failed." ::= { atmNteIdEntry 2 } atmNteUnitVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware and Software version of the module." ::= { atmNteIdEntry 3 } atmNteCardType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), sc13mR155 (2), st13sR155 (3), st13lR155 (4), utpR155 (5), cxBncR155 (6), e3 (7), t3 (8), e1 (9), e1Ltu (10), fc13lR155 (11), fc13lhR155 (12), fc15lhR155 (13), fc13lE3 (14), fc13lhE3 (15), fc15lhE3 (16), fc13lT3 (17), fc13lhT3 (18), fc15lhT3 (19), t1 (20), eth (21), ethE1CesBnc (22), ethE1CesRj45 (23), ethT1CesRj45 (24), e1CesRj45 (25), e1CesBnc (26), t1CesRj45 (27), e14Ces (28), e14CesRj45 (29), t14CesRj45 (30), hdlc4port (31), hdlcE14CesBnc (32), hdlcE14CesRj45 (33), hdlcT14CesRj45 (34), e1Rj45 (35), e1Bnc (36), ethE14CesBnc (37), ethE14CesRj45 (38), ethT14CesRj45 (39), hdlc1portHssi (40), hdlcHssiE14CesBnc (41), hdlcHssiE14CesRj45 (42), hdlcHssiT14CesRj45 (43), e14ImaRj45 (44), e14ImaBnc (45), t14ImaRj45 (46), ethE3CesBnc (47), ethT3CesBnc (48), smSf1R155 (49), smSf2R155 (50), sc13sR155 (51), sc13lR155 (52), utp25 (53), sc13lhR155 (54), sc15lhR155 (55), sc13ljR155 (56), sc13lhjR155 (57), sc15lhjR155 (58), e18Ces (59), e18CesRj45 (60), t18CesRj45 (61), sc13mR622 (62), -- st13sR622 (63), -- st13lR622 (64), -- utpR622 (65), -- cxBncR622 (66), -- fc13lR622 (67), -- fc13lhR622 (68), -- fc15lhR622 (69), -- smSf1R622 (70), -- smSf2R622 (71), -- sc13sR622 (72), sc13lR622 (73), sc13lhR622 (74), sc15lhR622 (75), fr4Port (76), t3j (77), fr1Port (78), hdlc1Port (79), sc13mR155D (80), sc13lR155D (81), fc13lR155D (82), st13lR155D (83), sc13lhR155D (84), fc13lhR155D (85), st13lhR155D (86), e18ImaBnc (87), e18ImaRj45 (88), t18ImaRj45 (89), lanUtpE (90), lanLc13lE (91), lanLc13mE (92), e14ImaRj45CfgMode (93), e14ImaBncCfgMode (94), t14ImaRj45CfgMode (95), sc13mR155R (96), --Dual for Redundancy sc13lR155R (97), --Dual for Redundancy fc13lR155R (98), --Dual for Redundancy st13lR155R (99), --Dual for Redundancy sc13lhR155R (100), --Dual for Redundancy fc13lhR155R (101), --Dual for Redundancy st13lhR155R (102), --Dual for Redundancy fEthUtpD (103), fEthSmD (104), fEthMmD (105), e14CesRj45Unbal (106), sc13mR155n (107), sc13lR155n (108), sc13lhR155n (109), sc15lhR155n (110), fc13lR155n (111), fc13lhR155n (112), fc15lhR155n (113), st13lR155n (114), lanUtp (115), lanLc13l (116), lanLc13m (117), e1FrHdlc (118), e1FrHdlcUnbal (119), t1FrHdlc (120), channelizedT3 (121), --for IP-MUX16 fc15lhR155D (122), --Dual STM-1 sc15lhR155D (123), --Dual STM-1 smSf1R155D (124), --Dual STM-1 smSf2R155D (125), --Dual STM-1 smSf3R155D (126), --Dual STM-1 fc15lhR155R (127), --Dual for Redundancy sc15lhR155R (128), --Dual for Redundancy smSf1R155R (129), --Dual for Redundancy smSf2R155R (130), --Dual for Redundancy smSf3R155R (131), --Dual for Redundancy st13lhR155n (132), --New STM-1 smSf1R155n (133), --New STM-1 smSf2R155n (134), --New STM-1 smSf3R155n (135), --New STM-1 t18CesNg (136), e18CesUnbalNg (137), e18CesBalNg (138), t14CesNg (139), e14CesUnbalNg (140), e14CesBalNg (141), t18ImaUniNg (142), e18ImaUniUnbalNg(143), e18ImaUniBalNg (144), t14ImaUniNg (145), e14ImaUniUnbalNg(146), e14ImaUniBalNg (147), t1Ces (148), e1CesUnbal (149), e1CesBal (150), switchedLan (151), --LAN card with ETH switch (usually 4 ports) channelizedSts1 (152), --Channelized STS1 card (for IP-MUX16) st13mR155 (153), st13lhR155 (154), st15lhR155 (155), gigabitEthUtp (156), gigabitEthSfp (157), fastEthUtp (158), main (251), control (252), fan (253), unknown (254), empty (255) -- values 1000 and up are reserved -- (used by atmNteProgCardType) } MAX-ACCESS read-only STATUS current DESCRIPTION "The card type." ::= { atmNteIdEntry 4 } atmNteCardStatus OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), notActive (2), active (3), inProgress (4), empty (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the card in the selected slot. notActive - Connections are in NotReady state. No configuration is available for the card. The access to the card HW is blocked. This state is relevant for an extracted card, and for a case in which the card was deactivated. active - The module installed and functions. A card that in this state can be configured. inProgress - The status during proccessing of a command from atmNteCardCmd. empty - No information is valid for the selected slot. This status is relevant to a case in which the card configaration was deleted, or in case in which a slot was empty since the device startup." ::= { atmNteIdEntry 5 } atmNteCardCmd OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), deleteConfig (2), deactivate (3), activate (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Command on the card that is installed in the selected slot. The commands are applicable according to the value of atmNteCardStatus. See the specification document for details. deleteConfig - Deletes the card configuration. deactivate - All the connections state will be changed to NotReady. The card configuration will be blocked. activate - Does the same as done upon card insertion: Initiates the relevant parameters, activates the physical layer, ATM layer and logical layer." ::= { atmNteIdEntry 6 } atmNteProgCardType OBJECT-TYPE SYNTAX INTEGER { -- values 1...1000 (if needed) should be used -- the same as in atmNteCardType main (251), control (252), fan (253), empty (255), atm155 (1001), eth (1002) } MAX-ACCESS read-write STATUS current DESCRIPTION "The programmed card type." ::= { atmNteIdEntry 7 } atmSysPSunits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of power supply units." ::= { atmNteSysInfo 2 } atmSysPSunitsInUse OBJECT-TYPE SYNTAX INTEGER { ps1(2), ps2(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The main power supply in this unit." ::= { atmNteSysInfo 3 } atmSysFanUnits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of fan units." ::= { atmNteSysInfo 4 } atmSysNetPrts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of network ports." ::= { atmNteSysInfo 5 } atmSysNetPrtInUse OBJECT-TYPE SYNTAX INTEGER { trunk1(2), trunk2(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The network port in use." ::= { atmNteSysInfo 6 } atmNteBridgingMode OBJECT-TYPE SYNTAX INTEGER { accessOnly(1), accessAndSwitching (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Bridging mode can be one of the following: ATM <> Ethernet - Bridging is between the Ethernet port and the ATM port (there is no bridging between VCs). ATM <> Ethernet + ATM - Bridging is done both between the Ethernet port and the ATM port and also between VCs." ::= { atmNteSysInfo 7} atmSysStats OBJECT IDENTIFIER ::= { atmNteSysInfo 8 } atmSysCurrentCdc OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Seconds in which cells dropped was occured in the current 15 minutes interval." ::= { atmSysStats 1 } atmSysIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSysIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The system level Interval table." ::= { atmSysStats 2 } atmSysIntervalEntry OBJECT-TYPE SYNTAX AtmSysIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { atmSysIntervalNumber } ::= { atmSysIntervalTable 1 } AtmSysIntervalEntry ::= SEQUENCE { atmSysIntervalNumber Integer32, atmSysIntervalCdc Gauge32 } atmSysIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { atmSysIntervalEntry 1 } atmSysIntervalCdc OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Seconds in which cells dropped was occured in 15 minutes interval." ::= { atmSysIntervalEntry 2 } atmNteEventType OBJECT-TYPE SYNTAX INTEGER { ps1NotActive (3), ps1Active (4), ps2NotActive (5), ps2Active (6), heatAlarmOff (7), heatAlarmOn (8), inputAlarm1Off (9), inputAlarm1On (10), inputAlarm2Off (11), inputAlarm2On (12), inputAlarm3Off (13), inputAlarm3On (14), inputAlarm4Off (15), inputAlarm4On (16), fan1Ok (17), fan1Fail (18), fan2Ok (19), fan2Fail (20), invalidLogin (21), validLogin (22), powerFailure (23), writeToFlashFailure (24) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter identifies the event. On - the problem exist. Off - the problem not exist. InvalidLogin - Invalid login on local console. CorrectLogin - Successful login operation." ::= { atmNteSysInfo 9 } atmNteIntervalMaxNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The MAX number of connections intervals supported by system. This parameter value is a function of atmNteConnectionsMaxNumber parameter. This parameter should affect the threshold values selected by user. Applicable to ace2002." ::= { atmNteSysInfo 10 } atmNteAlarmType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), ais(2), rdi(3), continuityLoss(4), loopback(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the type of the alarm." ::= { atmNteSysInfo 11 } atmNteLevel OBJECT-TYPE SYNTAX INTEGER { vp(2), vc(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the ATM level." ::= { atmNteSysInfo 12 } atmNteConnectionsNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies a quantity of connections." ::= { atmNteSysInfo 13 } atmNteTotalLb OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter counts the total number of end-points that were configured with Loopback (LB)." ::= { atmNteSysInfo 14 } atmNteTotalCc OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter counts the total number of end-points that were configured with Continuity Check (CC)." ::= { atmNteSysInfo 15 } atmNteTotalPm OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter counts the total number of end-points that were configured with PM." ::= { atmNteSysInfo 16 } --atmNtePrt OBJECT IDENTIFIER ::= {atmNte 2} -- Changed atmNteLoopback OBJECT IDENTIFIER ::= {atmNtePrt 2} -- The loopback test consists of inserting special OAM cells. This test is started and stopped -- upon operator request (by using MIB item atmVpConfLoopbackAdminStatus). -- There are two tables per VP and two tables per VC: the measurements of the current 15 minutes, -- and the measurement of the last 96 periods of 15 minutes. atmLoopbackVpTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLoopbackVpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters for an OAM VP loopback test." ::= {atmNteLoopback 1 } atmLoopbackVpEntry OBJECT-TYPE SYNTAX AtmLoopbackVpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table atmLoopbackVpTable." INDEX {atmLoopbackVpIfIndex,atmLoopbackVpVpi} ::= {atmLoopbackVpTable 1} AtmLoopbackVpEntry ::= SEQUENCE { atmLoopbackVpIfIndex Integer32, atmLoopbackVpVpi Integer32, atmLoopbackVpOperStatus INTEGER, atmLoopbackVpCDV Integer32, atmLoopbackVpAverageDelay Integer32, atmLoopbackVpMaxDelay Integer32, atmLoopbackVpMinDelay Integer32, atmLoopbackVpErrSessions Integer32 } atmLoopbackVpIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index of the ATM layer." ::= {atmLoopbackVpEntry 1} atmLoopbackVpVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the OAM VPL." ::= {atmLoopbackVpEntry 2} atmLoopbackVpOperStatus OBJECT-TYPE SYNTAX INTEGER { noActive(1), inProgress(2), failed(3), endSuccessfully(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "-noActive(1) means that the loopback test has not been activated for this VP. -inProgress(2) means that the test has been activated and there is currently no problem. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was stopped and all was OK." ::= {atmLoopbackVpEntry 3} atmLoopbackVpCDV OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Delay Variation for this sampling." ::= {atmLoopbackVpEntry 4} atmLoopbackVpAverageDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Average delay without including lost cells." ::= {atmLoopbackVpEntry 5} atmLoopbackVpMaxDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum delay without including lost cells." ::= {atmLoopbackVpEntry 6} atmLoopbackVpMinDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum delay." ::= {atmLoopbackVpEntry 7} atmLoopbackVpErrSessions OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Errored Sessions. Will be updated once in 5 seconds." ::= {atmLoopbackVpEntry 8} atmLoopbackVcTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLoopbackVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters for an OAM VC loopback test." ::= {atmNteLoopback 2 } atmLoopbackVcEntry OBJECT-TYPE SYNTAX AtmLoopbackVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {atmLoopbackVcIfIndex,atmLoopbackVcVpi,atmLoopbackVcVci} ::= {atmLoopbackVcTable 1} AtmLoopbackVcEntry ::= SEQUENCE { atmLoopbackVcIfIndex Integer32, atmLoopbackVcVpi Integer32, atmLoopbackVcVci Integer32, atmLoopbackVcOperStatus INTEGER, atmLoopbackVcCDV Integer32, atmLoopbackVcAverageDelay Integer32, atmLoopbackVcMaxDelay Integer32, atmLoopbackVcMinDelay Integer32, atmLoopbackVcErrSessions Integer32 } atmLoopbackVcIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index of the ATM layer." ::= {atmLoopbackVcEntry 1} atmLoopbackVcVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the OAM VCL." ::= {atmLoopbackVcEntry 2} atmLoopbackVcVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the OAM VCL." ::= {atmLoopbackVcEntry 3} atmLoopbackVcOperStatus OBJECT-TYPE SYNTAX INTEGER { noActive(1), inProgress(2), failed(3), endSuccessfully(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "-noActive(1) means that the loopback test has not been activated for this VP. -inProgress(2) means that the test has been activated and there is currently no problem. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was stopped and all was OK." ::= {atmLoopbackVcEntry 4} atmLoopbackVcCDV OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Delay Variation for this sampling." ::= {atmLoopbackVcEntry 5} atmLoopbackVcAverageDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Average delay without including lost cells." ::= {atmLoopbackVcEntry 6} atmLoopbackVcMaxDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum delay without including lost cells." ::= {atmLoopbackVcEntry 7} atmLoopbackVcMinDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum delay." ::= {atmLoopbackVcEntry 8} atmLoopbackVcErrSessions OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Errored Sessions. Will be updated once in 5 seconds." ::= {atmLoopbackVcEntry 9} -- Entirely New atmLoopbackVpIvlTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLoopbackVpIvlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters for an OAM VP loopback test, according interval number." ::= {atmNteLoopback 3 } atmLoopbackVpIvlEntry OBJECT-TYPE SYNTAX AtmLoopbackVpIvlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { atmLoopbackVpIvlIfIndex, atmLoopbackVpIvlVpi, atmLoopbackVpIvlIvl } ::= { atmLoopbackVpIvlTable 1} AtmLoopbackVpIvlEntry ::= SEQUENCE { atmLoopbackVpIvlIfIndex Integer32, atmLoopbackVpIvlVpi Integer32, atmLoopbackVpIvlIvl Integer32, atmLoopbackVpIvlOperStatus INTEGER, atmLoopbackVpIvlCDV Integer32, atmLoopbackVpIvlAverageDelay Integer32, atmLoopbackVpIvlMaxDelay Integer32, atmLoopbackVpIvlMinDelay Integer32, atmLoopbackVpIvlErrSessions Integer32 } atmLoopbackVpIvlIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index of the ATM layer." ::= { atmLoopbackVpIvlEntry 1} atmLoopbackVpIvlVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the OAM VPL." ::= { atmLoopbackVpIvlEntry 2} atmLoopbackVpIvlIvl OBJECT-TYPE SYNTAX Integer32(1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The relevant interval number." ::= { atmLoopbackVpIvlEntry 3} atmLoopbackVpIvlOperStatus OBJECT-TYPE SYNTAX INTEGER { noActive(1), inProgress(2), failed(3), endSuccessfully(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "-noActive(1) means that the loopback test has not been activated for this VP during this interval. -inProgress(2) has no meaning for an ended interval. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was OK." ::= { atmLoopbackVpIvlEntry 4} atmLoopbackVpIvlCDV OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Delay Variation for this interval." ::= { atmLoopbackVpIvlEntry 5} atmLoopbackVpIvlAverageDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Average delay without including lost cells for this interval." ::= { atmLoopbackVpIvlEntry 6} atmLoopbackVpIvlMaxDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum delay without including lost cells for this interval." ::= { atmLoopbackVpIvlEntry 7} atmLoopbackVpIvlMinDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum delay for this interval." ::= {atmLoopbackVpIvlEntry 8} atmLoopbackVpIvlErrSessions OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Errored Sessions. Will be updated once in 5 seconds." ::= {atmLoopbackVpIvlEntry 9} atmLoopbackVcIvlTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLoopbackVcIvlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters for an OAM VC loopback test." ::= {atmNteLoopback 4 } atmLoopbackVcIvlEntry OBJECT-TYPE SYNTAX AtmLoopbackVcIvlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {atmLoopbackVcIvlIfIndex, atmLoopbackVcIvlVpi, atmLoopbackVcIvlVci, atmLoopbackVcIvlIvl } ::= {atmLoopbackVcIvlTable 1} AtmLoopbackVcIvlEntry ::= SEQUENCE { atmLoopbackVcIvlIfIndex Integer32, atmLoopbackVcIvlVpi Integer32, atmLoopbackVcIvlVci Integer32, atmLoopbackVcIvlIvl Integer32, atmLoopbackVcIvlOperStatus INTEGER, atmLoopbackVcIvlCDV Integer32, atmLoopbackVcIvlAverageDelay Integer32, atmLoopbackVcIvlMaxDelay Integer32, atmLoopbackVcIvlMinDelay Integer32, atmLoopbackVcIvlErrSessions Integer32 } atmLoopbackVcIvlIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index of the ATM layer." ::= {atmLoopbackVcIvlEntry 1} atmLoopbackVcIvlVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the OAM VCL." ::= {atmLoopbackVcIvlEntry 2} atmLoopbackVcIvlVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the OAM VCL." ::= {atmLoopbackVcIvlEntry 3} atmLoopbackVcIvlIvl OBJECT-TYPE SYNTAX Integer32(1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The relevant interval number." ::= {atmLoopbackVcIvlEntry 4} atmLoopbackVcIvlOperStatus OBJECT-TYPE SYNTAX INTEGER { noActive(1), inProgress(2), failed(3), endSuccessfully(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "-noActive(1) means that the loopback test has not been activated for this VC during this interval. -inProgress(2) has no meaning per interval. -failed(3) means there was problem for this test during this interval. -endSuccessfully(4) means that the test was OK." ::= {atmLoopbackVcIvlEntry 5} atmLoopbackVcIvlCDV OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Delay Variation for this interval." ::= {atmLoopbackVcIvlEntry 6} atmLoopbackVcIvlAverageDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Average delay without including lost cells." ::= {atmLoopbackVcIvlEntry 7} atmLoopbackVcIvlMaxDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum delay without including lost cells." ::= {atmLoopbackVcIvlEntry 8} atmLoopbackVcIvlMinDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum delay." ::= {atmLoopbackVcIvlEntry 9} atmLoopbackVcIvlErrSessions OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Errored Sessions. Will be updated once in 5 seconds." ::= {atmLoopbackVcIvlEntry 10} atmNtePM OBJECT IDENTIFIER ::= {atmNtePrt 3} atmVpPmTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpPmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters for VP performance monitoring." ::= {atmNtePM 1 } atmVpPmEntry OBJECT-TYPE SYNTAX AtmVpPmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {atmVpPmIfIndex,atmVpPmVpi} ::= {atmVpPmTable 1} AtmVpPmEntry ::= SEQUENCE { atmVpPmIfIndex Integer32, atmVpPmVpi Integer32, atmVpPmAdminStatus INTEGER, atmVpPmDirection INTEGER, atmVpPmBlockSize Integer32, atmVpPmRowStatus RowStatus, atmVpPmSink INTEGER, atmVpPmSource INTEGER } atmVpPmIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index of the ATM layer." ::= {atmVpPmEntry 1} atmVpPmVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the Performance Monitoring VPL." ::= {atmVpPmEntry 2} atmVpPmAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (2), down(3), listenToActivationCells (4), originateActivationCells (5) } MAX-ACCESS read-create STATUS current DESCRIPTION "up(2) - Activate PM. down(3) - Deactivate PM. listenToActivationCells(4) - . originateActivationCells(5) - ." ::= {atmVpPmEntry 3} atmVpPmDirection OBJECT-TYPE SYNTAX INTEGER { source(2), destination(3), bidirectional(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "The direction of PM." ::= {atmVpPmEntry 4} atmVpPmBlockSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096, 8192, 16384, 32768." ::= {atmVpPmEntry 5} atmVpPmRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= {atmVpPmEntry 6} atmVpPmSink OBJECT-TYPE SYNTAX INTEGER { off (1), fwd (2), fwdAndBwdReport(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting." ::= {atmVpPmEntry 7} atmVpPmSource OBJECT-TYPE SYNTAX INTEGER { off (1), fwd (2), fwdAndBwdReport(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting." ::= {atmVpPmEntry 8} atmVcPmTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcPmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters for VC performance monitoring." ::= {atmNtePM 2 } atmVcPmEntry OBJECT-TYPE SYNTAX AtmVcPmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {atmVcPmIfIndex,atmVcPmVpi,atmVcPmVci} ::= {atmVcPmTable 1} AtmVcPmEntry ::= SEQUENCE { atmVcPmIfIndex Integer32, atmVcPmVpi Integer32, atmVcPmVci Integer32, atmVcPmAdminStatus INTEGER, atmVcPmDirection INTEGER, atmVcPmBlockSize Integer32, atmVcPmRowStatus RowStatus, atmVcPmSink INTEGER, atmVcPmSource INTEGER } atmVcPmIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index of the ATM layer." ::= {atmVcPmEntry 1} atmVcPmVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the Performance Monitoring VCL." ::= {atmVcPmEntry 2} atmVcPmVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the PM VCL." ::= {atmVcPmEntry 3} atmVcPmAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (2), down(3), listenToActivationCells (4), originateActivationCells (5) } MAX-ACCESS read-create STATUS current DESCRIPTION "up(2) - Activate PM. down(3) - Deactivate PM. listenToActivationCells(4) - . originateActivationCells(5) - ." ::= {atmVcPmEntry 4} atmVcPmDirection OBJECT-TYPE SYNTAX INTEGER { source(2), destination(3), bidirectional(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "The direction of PM." ::= {atmVcPmEntry 5} atmVcPmBlockSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096, 8192, 16384, 32768." ::= {atmVcPmEntry 6} atmVcPmRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= {atmVcPmEntry 7} atmVcPmSink OBJECT-TYPE SYNTAX INTEGER { off (1), fwd (2), fwdAndBwdReport(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting." ::= {atmVcPmEntry 8} atmVcPmSource OBJECT-TYPE SYNTAX INTEGER { off (1), fwd (2), fwdAndBwdReport(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting." ::= {atmVcPmEntry 9} atmNteMdl OBJECT IDENTIFIER ::= {atmNte 3} atmNteMdlConfig OBJECT IDENTIFIER ::= {atmNteMdl 1} atmNteMdlConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteMdlConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Module configuration table." ::= { atmNteMdlConfig 1 } atmNteMdlConfigEntry OBJECT-TYPE SYNTAX AtmNteMdlConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "There is an entry in this table just for those modules that have parameters that are relevant to module level only." INDEX {atmNteMdlSlotIndex} ::= {atmNteMdlConfigTable 1} AtmNteMdlConfigEntry ::= SEQUENCE { atmNteMdlSlotIndex Integer32, atmNteMdlPrtCpuSharing INTEGER, atmNteMdlInputPriorityMechanism INTEGER } atmNteMdlSlotIndex OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The slot number." ::= { atmNteMdlConfigEntry 1} atmNteMdlPrtCpuSharing OBJECT-TYPE SYNTAX INTEGER { equal (2), port1 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object lets the user decide what will be the CPU sharing between the ports of the module. This object is applicable for modules in which the same CPU handles the traffic of all ports. equal - All ports will have the same CPU resource. port1 - Port 1 will have higher priority than the other ports." ::= {atmNteMdlConfigEntry 2} atmNteMdlInputPriorityMechanism OBJECT-TYPE SYNTAX INTEGER { disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows the user to Enable/Disable the Input priority mechanism. This object is applicable for modules with more than one port, in which the total ports input may be greater than the port output. disabled - all LAN VCCs will be transmitted through the same queue (queue 1). Upon congestion frames will be dropped randomly. enabled - the user should configure each port/connection priority. Upon congestion frames will be dropped according to priority." ::= {atmNteMdlConfigEntry 3} atmGenSystem OBJECT IDENTIFIER ::= {atmGen 2} --atmGenModules OBJECT IDENTIFIER ::= {atmGen 3} located in ace2002.txt atmGenSysGen OBJECT IDENTIFIER ::= {atmGenSystem 1} -- The self test table atmGenSysSelfTestTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmGenSysSelfTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing the results of the initial testing of the device." ::= { atmGenSysGen 1 } atmGenSysSelfTestEntry OBJECT-TYPE SYNTAX AtmGenSysSelfTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {atmGenSysSelfTestIndex} ::= {atmGenSysSelfTestTable 1} AtmGenSysSelfTestEntry ::= SEQUENCE { atmGenSysSelfTestIndex Integer32, atmGenSysSelfTestResult DisplayString } atmGenSysSelfTestIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A running index for the table." ::= { atmGenSysSelfTestEntry 1} atmGenSysSelfTestResult OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The results of the initial testing of the device." ::= { atmGenSysSelfTestEntry 2} -- The Log clear all atmGenSysLogClearAll OBJECT-TYPE SYNTAX INTEGER { off(2),clear(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the variable to clear(3) removes all entries in the Log Buffer of the agent. The agent will immediately reset the variable to off(2)." ::= { atmGenSysGen 2} -- The Log table atmGenSysLogTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmGenSysLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A copy of the log buffer." ::= { atmGenSysGen 3 } atmGenSysLogEntry OBJECT-TYPE SYNTAX AtmGenSysLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {atmGenSysLogIndex} ::= {atmGenSysLogTable 1} AtmGenSysLogEntry ::= SEQUENCE { atmGenSysLogIndex Integer32, atmGenSysLogMessage DisplayString } atmGenSysLogIndex OBJECT-TYPE SYNTAX Integer32 (1..2048) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the log buffer." ::= { atmGenSysLogEntry 1} atmGenSysLogMessage OBJECT-TYPE SYNTAX DisplayString (SIZE(80)) MAX-ACCESS read-only STATUS current DESCRIPTION "The log buffer entry message text." ::= { atmGenSysLogEntry 2} -- Set to default configuration atmGenSysSetDefaultConfg OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When set to on(3), the agent will set all the configuration parameters to their default values. The variable is then reset to off(2) by the agent. The agent must be reset for the default configuration to apply." ::= {atmGenSysGen 4} -- A Cross Reference table for connections between tables. atmGenSysCxRefTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmGenSysCxRefEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Cross Reference table. The table maintains an index of an object which is also the table index, and a counter that indicates how many times this object was referenced. When using this table for more than one referenced table, which uses the same range of indexes, then the index should be shifted by a unique offset per table. In ACE2002 this table is used for TD and for FR Desc. Thus, the index for FR Descriptor is: FR Descriptor index + offset. The offset is described in the ACE2002 NMS SRS." ::= {atmGenSysGen 5} atmGenSysCxRefEntry OBJECT-TYPE SYNTAX AtmGenSysCxRefEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entries will be added by the agent upon an entry addition in the referenced tables (TD table, FR Descriptor etc.)" INDEX { atmGenSysCxRefIndex } ::= { atmGenSysCxRefTable 1 } AtmGenSysCxRefEntry ::= SEQUENCE { atmGenSysCxRefIndex Integer32, atmGenSysCxRefCounter Gauge32 } atmGenSysCxRefIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index specifies an entry in the table of the object." ::= { atmGenSysCxRefEntry 1 } atmGenSysCxRefCounter OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter counts the number of references that have been made to the object ." ::= { atmGenSysCxRefEntry 2 } -- Traps -- System Layer Traps atmAceStatusChange NOTIFICATION-TYPE OBJECTS {agnLed,agnIndication} STATUS current DESCRIPTION "The trap is sent every time there is a change in the state of one of the LEDs." ::= { atmNteEvents 1 } atmAceAlarmTrap NOTIFICATION-TYPE OBJECTS {atmInterfaceAlarmStatus} STATUS current DESCRIPTION "The trap is sent whenever there is a transition from a no alarm state to a state with at least one active alarm. An active alarm state exists if: 1) The atmInterfaceActiveAlarms vector is different than 0. 2) The atmNteAlarmVpTable contains entries. 3) The atmNteAlarmVcTable contains entries. The trap is also sent when a transition into the no alarm state occurs. The second variable will be atmInterfaceActiveAlarms to indicate the kind of the alarm. The trap is not sent more than once in a 10 second interval." ::= { atmNteEvents 2 } atmAceModuleChangeTrap NOTIFICATION-TYPE OBJECTS {ifIndex} STATUS current DESCRIPTION "The trap is sent every time a module is changed (Hot swapping). The second variable will be atmNteCardType to indicate the type of card that was inserted. The value empty(255) indicates that a card was taken out." ::= { atmNteEvents 3 } atmAceRedundancyTrap NOTIFICATION-TYPE OBJECTS {ifIndex } STATUS current DESCRIPTION "The trap is sent upon change in link as a result of redundancy. The ifIndex parameter indicates the current active link." ::= { atmNteEvents 4 } atmAceModuleMismatchTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "The trap is sent upon starting or stopping of a module mismatch state. A possible mismatch is when the inserted module is other than the programmed one." ::= { atmNteEvents 5 } atmAceSystemTrap NOTIFICATION-TYPE OBJECTS { atmNteEventType, agnLed, alarmSeverity } STATUS current DESCRIPTION "This trap alerts of major problems in the device." ::= { radSysAtmEvents 6 } atmAceAlarmForwardingTrap NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState } STATUS current DESCRIPTION "This trap is sent upon starting or stopping Alarm Forwarding Mechanism." ::= { radSysAtmEvents 7 } atmAceDateAndTimeRequest NOTIFICATION-TYPE -- OBJECTS { sysObjectID } STATUS current DESCRIPTION "This trap is sent upon restart. It will send sysObjectID variable. Upon recieving this trap the NMS will set the device's date and time. This trap's purpose is to fix a problem in ACE2002, ACE-2002E, ACE-202. The problem is that the Date and Time is stored in the NVRAM, and when the NVRAM's battery is empty, the device loses this information." ::= { radSysAtmEvents 8 } -- Alarms Traps atmAceAlarmLOS NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Loss Of Signal." ::= { radSysAtmEvents 16 } atmAceAlarmLOF NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Loss Of Frame." ::= { radSysAtmEvents 17 } atmAceAlarmLCD NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Loss of Cell Delineation." ::= { radSysAtmEvents 18 } atmAceAlarmSLM NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Signal Line Mismatch." ::= { radSysAtmEvents 19 } atmAceAlarmLOP NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Loss of Pointer." ::= { radSysAtmEvents 20 } atmAceAlarmLineAIS NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Line AIS." ::= { radSysAtmEvents 21 } atmAceAlarmPathAIS NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Path AIS." ::= { radSysAtmEvents 22 } atmAceAlarmLineRDI NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Line RDI." ::= { radSysAtmEvents 23 } atmAceAlarmPathRDI NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Path RDIand Path RAI(Yellow) for DS1 interfaces." ::= { radSysAtmEvents 24 } atmAceAlarmSectionBIP NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Section Bit Interleave Parity." ::= { radSysAtmEvents 25 } atmAceAlarmLineBIP NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Line Bit Interleave Parity." ::= { radSysAtmEvents 26 } atmAceAlarmPathBIP NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Path Bit Interleave Parity." ::= { radSysAtmEvents 27 } atmAceAlarmLineFEBE NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Line Far End Block Error." ::= { radSysAtmEvents 28 } atmAceAlarmPathFEBE NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Path Far End Block Error." ::= { radSysAtmEvents 29 } atmAceAlarmPlcpLOF NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates T3 PLCP Loss Of Frame." ::= { radSysAtmEvents 30 } atmAceAlarmPlcpYELLOW NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates T3 Plcp Yellow." ::= { radSysAtmEvents 31 } atmAceAlarmPlcpBIP NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates T3 Plcp Bit Interleave Parity." ::= { radSysAtmEvents 32 } atmAceAlarmPlcpFEBE NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates T3 Plcp Far End Block Error." ::= { radSysAtmEvents 33 } atmAceAlarmPlcpP1P2 NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates T3 Plcp Parity errors in P1/P2 bytes." ::= { radSysAtmEvents 34 } atmAceAlarmUAS NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap is sent upon UAS start or end per port." ::= { radSysAtmEvents 35 } atmAceAlarmCluster NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, atmNteAlarmType, atmNteLevel } STATUS current DESCRIPTION "This trap is sent upon atmNteAlarmType start or end, for a cluster of VPs/VCs (according to atmNteLevel) with the same alarm on the same physical port. This trap replaces sending the same alarm for a big quantity (the quantity described in the product specification document) of VPs/VCs in order to prevent flooding the NMS and the network with traps." ::= { radSysAtmEvents 36 } atmAceHwFailure NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap is sent upon HW failure per port." ::= { radSysAtmEvents 37 } atmAceUnavailableBwTrap NOTIFICATION-TYPE OBJECTS { alarmSeverity, ifAlias, atmConfIfInputRate, atmConfIfOutputRate } STATUS current DESCRIPTION "This trap is sent when Bandwidth allocation is > max possible value for the installed card. For ACE2002 this trap will be sent for the following cases: Card insertion - if the total Input and/or Output Bandwidth is over allocated, then the specific card rate will be set to 0 and this trap will be sent with the Input/Output rates values. Upgrade from former version - when an over allocated Bandwidth is detected, this trap will be sent with atmConfIfInputRate=atmConfIfOutputRate=0xFFFFFFFF." ::= { radSysAtmEvents 38 } -- -- OAM LOOPBACK -- atmAceOAMLoopBackCellRx NOTIFICATION-TYPE -- OBJECTS { alarmSeverity, alarmState,ifAlias } -- STATUS current -- DESCRIPTION -- "This Trap indicates that a loopback has -- been activated on device ATM uplink interface -- by the remote ATM equipment, by means of OAM cells" -- ::= { radSysAtmEvents 39 } -- -- -- OAM LOOPBACK -- atmAceOAMLoopBackCellTx NOTIFICATION-TYPE -- OBJECTS { alarmSeverity, alarmState,ifAlias } -- STATUS current -- DESCRIPTION -- "This Trap indicates that a loopback has -- been initiated by local device on ATM uplink interface -- towards remote ATM equipment, by sending OAM cells." -- ::= { radSysAtmEvents 15 } -- VP Layer Traps -- atmVplVpi have MAX-ACCESS "not-accessible" -- and cannot be referenced from NOTIFICATION-TYPE clause -- in SMIV2 so they where removed from following caluses. -- Dovi Korngut (28/6/00). atmAceAlarmVpContinuityLoss NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Loss of Continuity Check on a VP Connection." ::= { radSysAtmEvents 40 } atmAceAlarmVpAISReception NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates AIS Reception on a VP Connection." ::= { radSysAtmEvents 41 } atmAceAlarmVpRDIReception NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates RDI Reception on a VP Connection." ::= { radSysAtmEvents 42 } atmAceAlarmVpErroredCells NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Errored Cells on a VP Connection reported by PM." ::= { radSysAtmEvents 43 } atmAceAlarmVpLostCells NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Lost Cells on a VP Connection reported by PM." ::= { radSysAtmEvents 44 } atmAceAlarmVpMisinsertedCells NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Misinserted Cells on a VP Connection reported by PM." ::= { radSysAtmEvents 45 } atmAceAlarmVpUAS NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap is sent upon UAS start or end per VP." ::= { radSysAtmEvents 46 } atmAceAlarmVpLoopback NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap is sent upon OAM LoopBack fail status per VP." ::= { radSysAtmEvents 47 } atmAceAlarmVpGCRAViolation NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates GCRA violation on a VP Connection reported by UPC device." ::= { radSysAtmEvents 48 } -- VC Layer Traps -- atmVclVpi and atmVclVci have MAX-ACCESS "not-accessible" -- and cannot be referenced from NOTIFICATION-TYPE clause -- in SMIV2 so they where removed from following caluses. -- Dovi Korngut (28/6/00). atmAceAlarmVcContinuityLoss NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Loss of Continuity Check on a VC Connection." ::= { radSysAtmEvents 56 } atmAceAlarmVcAISReception NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates AIS Reception on a VC." ::= { radSysAtmEvents 57 } atmAceAlarmVcRDIReception NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates RDI Reception on a VC Connection." ::= { radSysAtmEvents 58 } atmAceAlarmVcErroredCells NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Errored Cells on a VC Connection reported by PM." ::= { radSysAtmEvents 59 } atmAceAlarmVcLostCells NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Lost Cells on a VC Connection reported by PM." ::= { radSysAtmEvents 60 } atmAceAlarmVcMisinsertedCells NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Misinserted Cells on a VC Connection reported by PM." ::= { radSysAtmEvents 61 } atmAceAlarmVcUnexpectedCell NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates an unexpected cell from user or network port." ::= { radSysAtmEvents 62 } atmAceAlarmVcUAS NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap is sent upon UAS start or end per VC." ::= { radSysAtmEvents 63 } atmAceAlarmVcLoopback NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap is sent upon OAM LoopBack fail status per VC." ::= { radSysAtmEvents 64 } atmAceAlarmVcGCRAViolation NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates GCRA violation on a VC Connection reported by UPC device." ::= { radSysAtmEvents 65 } -- number 80 and up are saved for IMA traps -- END -- SENDING OAM VC-AIS CELLS ?? -- This message appears when the LA-110 starts/stop -- transmitting OAM cells of type VC-AIS to the -- ATM network the alarm description -- will be followed with the relevant VP/VC -- -- SENDING OAM VC-RDI CELLS ??? -- This message appears when the LA-110 start/stop -- transmitting OAM cells of type VC-RDI to the -- ATM network the alarm description will be -- followed with the relevant VP/VC -- -- -- file :v:\doc\rdv\mib\ver485\ipRouter.txt -- --Version: 1.0 --Date: 31.01.99 --By: Ilana Schvetz --File: ipRouter.txt -- --Last Update: Ilana Schvetz 09/01/02 --radRouter OBJECT IDENTIFIER ::= { rad 11 } --rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 } ipRouter OBJECT IDENTIFIER ::= { rtrBridge 3 } rtrIfIpTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrIfIpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Router interfaces table." ::= { ipRouter 1 } rtrIfIpEntry OBJECT-TYPE SYNTAX RtrIfIpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table rtrIfIpTable." INDEX { rtrIfIp } ::= { rtrIfIpTable 1 } RtrIfIpEntry ::= SEQUENCE { rtrIfIp IpAddress, rtrIfRowStatus RowStatus, rtrIfIpMask IpAddress, rtrIfIndex Integer32, rtrIfMng INTEGER, rtrIfVlanId VlanIndex } rtrIfIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "IP Address." ::= { rtrIfIpEntry 1 } rtrIfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "." ::= { rtrIfIpEntry 2 } rtrIfIpMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "IP mask Address." ::= { rtrIfIpEntry 3 } rtrIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The ifIndex connection, on which the IP is determined." ::= { rtrIfIpEntry 4 } rtrIfMng OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "An IP interface might be determined as a management connection (under the product limitations)." ::= { rtrIfIpEntry 5 } rtrIfVlanId OBJECT-TYPE SYNTAX VlanIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The VLAN ID assigned to Tagged frames transmitted from this port. The value inserted should be a defined VLAN." ::= { rtrIfIpEntry 6 } -- Brouter Table brtrIfTable OBJECT-TYPE SYNTAX SEQUENCE OF BrtrIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "LAN interface table." ::= { ipRouter 2 } brtrIfEntry OBJECT-TYPE SYNTAX BrtrIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entries of this table will be created by agent." INDEX { brtrIfIndex } ::= { brtrIfTable 1 } BrtrIfEntry ::= SEQUENCE { brtrIfIndex Integer32, brtrIfMode INTEGER, brtrIfMaxFrameSize Integer32 } brtrIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the interface (LAN or ATM)." ::= { brtrIfEntry 1 } brtrIfMode OBJECT-TYPE SYNTAX INTEGER { bridge (1), router (2), brouter (3), off (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Connection Mode." ::= { brtrIfEntry 2 } brtrIfMaxFrameSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Frame Max Size." ::= { brtrIfEntry 3 } rtrArpAgingTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "ARP Aging Time. Applicable for a Router Mode and for a Brouter Mode." ::= { ipRouter 3 } -- Brouter LAN If table brtrLanIfTable OBJECT-TYPE SYNTAX SEQUENCE OF BrtrLanIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "LAN interface table." ::= { ipRouter 4 } brtrLanIfEntry OBJECT-TYPE SYNTAX BrtrLanIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entries of this table will be created by agent ." INDEX { brtrLanIfIndex } ::= { brtrLanIfTable 1 } BrtrLanIfEntry ::= SEQUENCE { brtrLanIfIndex Integer32, brtrLanIpAddress IpAddress, brtrLanIpMask IpAddress, brtrLanMaxRateEnable INTEGER, brtrLanMaxRate Integer32, brtrLanMng INTEGER, brtrLanDefaultRouter IpAddress } brtrLanIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the LAN entity (physical interface)." ::= { brtrLanIfEntry 1 } brtrLanIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Host IP address. Applicable for bridge mode connection only." ::= { brtrLanIfEntry 2 } brtrLanIpMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Host IP Mask. Applicable for bridge mode connection only." ::= { brtrLanIfEntry 3 } brtrLanMaxRateEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter determines the HW ability of the LAN card according to HW." ::= { brtrLanIfEntry 4 } brtrLanMaxRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Max Rate." ::= { brtrLanIfEntry 5 } brtrLanMng OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "An IP interface might be determined as a management connection (under the product limitations)." ::= { brtrLanIfEntry 6 } brtrLanDefaultRouter OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Default Router's (Gateway's) IP Address. For each LAN interface there may be a different Default Router." ::= { brtrLanIfEntry 7 } rtrIsdnIfTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrIsdnIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains ISDN parameters that do not appear in the standard MIBs." ::= { ipRouter 5 } rtrIsdnIfEntry OBJECT-TYPE SYNTAX RtrIsdnIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for ISDN parameters that do not appear in the standard MIBs." AUGMENTS { isdnSignalingEntry } -- INDEX { isdnSignalingIndex } ::= { rtrIsdnIfTable 1 } RtrIsdnIfEntry ::= SEQUENCE { rtrIsdnIfMinNumBchans Integer32, rtrIsdnIfMaxNumBchans Integer32 } rtrIsdnIfMinNumBchans OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Minimum number of B channels that the ISDN Dialer of the router will use for Dialing out. This parameter will be used for the BOD (Bandwidth On Demand) feature. Dial up on B channels is according to the need of bandwidth for router data transfer. Voice calls have a higher priority than router data. In case of few time slots the voice calls will cause disconnection of data channels up to the limit of minimum number of B channels." ::= { rtrIsdnIfEntry 1 } rtrIsdnIfMaxNumBchans OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Maximum number of B channels that the ISDN Dialer of the router will use for Dialing out. This parameter will be used for the BOD (Bandwidth On Demand) feature. Dial up on B channels is according to the need of bandwidth for router data transfer. Voice calls have a higher priority than router data. No more than MAX B channels will be used by the ISDN dialer." ::= {rtrIsdnIfEntry 2 } rtrLcrTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrLcrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Least Cost Routing Table. The user will be able to set a prefix for an outgoing number that arrives with a predefined prefix in order to redirect the number for the LCR process to be achieved." ::= { ipRouter 6 } rtrLcrEntry OBJECT-TYPE SYNTAX RtrLcrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Least Cost Routing Entry." INDEX { ifIndex, rtrLcrOutIfIndex } ::= { rtrLcrTable 1 } RtrLcrEntry ::= SEQUENCE { rtrLcrOutIfIndex InterfaceIndex, rtrLcrRowStatus RowStatus, rtrLcrInPrefix DisplayString, rtrLcrOutPrefix DisplayString } rtrLcrOutIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The outgoing interface Number of the current route. The incoming interface number is the value of ifIndex." ::= { rtrLcrEntry 1 } rtrLcrRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row Status for adding/destroying rows." ::= { rtrLcrEntry 2 } rtrLcrInPrefix OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This prefix is part of the called number existing in the incoming packet." ::= {rtrLcrEntry 3 } rtrLcrOutPrefix OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This prefix will be inserted into the outgoing packet." ::= {rtrLcrEntry 4 } --radRouter OBJECT IDENTIFIER ::= { rad 11 } multicastGen OBJECT IDENTIFIER ::= { radRouter 8 } -- General Multicast Parameters multicastMode OBJECT-TYPE SYNTAX INTEGER { disable (2), wanToLan (3), wanToLanIgmp (4), lanToWan (5), bidirectional(6), transparent(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "According to this mode the packets will be forwarded. If disable (2) is selected, there will be no multicast." ::= { multicastGen 1 } -- -- file :v:\doc\rdv\mib\ver485\clksrc.txt -- -- file : clksrc.txt -- -- available for ACE2002. This file is part of dxc.txt. --Version: 1.0 --Date: 9.7.00 --By: Ilana Schvetz --File: v:\doc\rdv\mib\ver485\clksrc.txt --Last Update: 25.11.01 by Ilana -- Copyright 1997 RAD Data Communications, Ltd. -- All Rights Reserved. dacsMux OBJECT IDENTIFIER ::= {radWan 3} systemDacsMux OBJECT IDENTIFIER ::= {dacsMux 1} sysStatus OBJECT IDENTIFIER ::= {systemDacsMux 3} sysConfig OBJECT IDENTIFIER ::= {systemDacsMux 6} sysSClkSrc OBJECT-TYPE SYNTAX INTEGER { master (1), fallback(2), internal(3), ml (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the source of the system clock." ::= { sysStatus 7 } --System Configuration Parameters sysCClkSrcTable OBJECT-TYPE SYNTAX SEQUENCE OF SysCClkSrcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "All the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry." ::= { sysConfig 1} sysCClkSrcEntry OBJECT-TYPE SYNTAX SysCClkSrcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {sysCClkCnfgIdx, sysCClkSrcIdx} ::= { sysCClkSrcTable 1} SysCClkSrcEntry ::= SEQUENCE { sysCClkCnfgIdx Integer32, sysCClkSrcIdx INTEGER, sysCClkSrcMode INTEGER, sysCClkSrcPrt Integer32, sysCClkStationFreq INTEGER, sysCClkRevertiveTimeout Integer32 } sysCClkCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg." ::= { sysCClkSrcEntry 1} -- In phase I of DXC and FCD, only the values 1 (Cnfg1) and 255 -- (temp) are valid. sysCClkSrcIdx OBJECT-TYPE SYNTAX INTEGER { master (1), fallback (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "An index in the table. There are only two entries in the table. master - refers Master clock parameters fallback - refers Fallback clock parameters" ::= { sysCClkSrcEntry 2} sysCClkSrcMode OBJECT-TYPE SYNTAX INTEGER { none (1), internal (2), rxClk (3), station (4), lbt (5), ntr (6), adaptive (7), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the source the nodal timing is locked to. none - is an invalid option for Master clock. internal - is an invalid option for Fallback clock . station - is an invalid option for a stand-alone unit. lbt - loop-back timing ntr - A system locked reference clock adaptive - clcok locking is achieved by altering the clock according to the data load notApplicable - for ML source of Kmux or ML Timing combinations when Master/Fallback clock are not applicable." ::= { sysCClkSrcEntry 3} sysCClkSrcPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This entry is valid only when working in rxClk mode. For ACE2002 in case of invalid entry the return value will be 0. For other products in case of invalid entry the return value will be 9999. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The SP ports will be numbered as follows: - SP port 1 : 1 - SP port 2 : 2 For external ports the convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For Kmux, the port will be according to : Slot*100+Ch. For ACE2002 and LA140, the port will be ifIndex." ::= { sysCClkSrcEntry 4} sysCClkStationFreq OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), f1544Khz (2), f2048Khz (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the frequency of the station clock when the source is 'station'. The value will be applicable only when the sysCClkSrcMode is 'station'. " ::= { sysCClkSrcEntry 5} sysCClkRevertiveTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The time in seconds in which the system will monitor the higher level clock source, before decision to revert to that clock. In case the time is zero, revertive mode will be disabled." ::= { sysCClkSrcEntry 6} -- -- file :v:\doc\rdv\mib\ver495\sub_rtr.txt -- -- version 4.95 -- file :sub_rtr.txt -- --RTR-MIB -- --Last update: 30-Apr-2003 by Shay Harari --radRouter OBJECT IDENTIFIER ::= { rad 11 } RAD Router -- ************************************************ -- Interfaces Group -- Link Layer (layer 2) Configuration MIB -- ************************************************ -- The following MIB group is used by the Management/Configuration -- station to configure the device interfaces, -- physicals as well as virtuals. -- Each entry in the rtrDynamicIfConfigTable should have one of -- the extended rtType. -- It will also have a corresponding entry in the standard iftable. -- The implementation uses these inputs to build the interface -- layer of the device. The output is reflected in the -- ifTable and ifStackTable which are implementation dependent. rtrInterfaces OBJECT IDENTIFIER ::= { radRouter 1 } RtrIfConfigTYPE ::= INTEGER -- STATUS current -- DESCRIPTION -- "This type defines what type of sub-layer is used -- in each entr of rtrDynamicIfConfigTable. -- It should contain values from IANAifType -- type for standard sub-layer, and values (starting from 999 -- decimal) for private sub-layers. -- The values of the ifType field in ifTable should be taken -- from IANAifType only." { other(1), ethernetLan(6), -- From IANAifType iso88023Csmacd(7), tokenRingLan(9), fddi(15), basicISDN(20), primaryISDN(21), propPointToPoint(22), -- rndWAN slip(28), ppp(23), -- From IANAifType frameRelay(32), rs232(33), atm(37), x25ple(40), v35(45), fastEther(62), -- Fast Ethernet (100BaseT) fastEtherFX(69), -- Fast Ethernet (100BaseFX) virtualNet(500), cod(1001), -- Rad/Rnd private backUp(1002), dialUp(1004), b1isdn(1010), b2isdn(1011), ipBcst(1020), ipPtp(1021), ipxRaw(1022), ipxEtType(1023), ipxLlcSap(1024), ipxLlcSnap(1025), ipxPtp(1026), brgUnder(1027), wanDriver(1060), ethernetDriver(1061), tokenRingDriver(1062), fddiDriver (1064), -- RAD private FDDI driver virtualLan(1080), unknown(1100) } rtrConfigIfTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrConfigIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of configured interfaces." ::= { rtrInterfaces 1 } rtrConfigIfEntry OBJECT-TYPE SYNTAX RtrConfigIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry defines a configured interface." INDEX { rtrConfigIfIndex } ::= { rtrConfigIfTable 1 } RtrConfigIfEntry ::= SEQUENCE { rtrConfigIfIndex InterfaceIndex, rtrConfigIfType RtrIfConfigTYPE, rtrConfigIfName DisplayString, rtrConfigIfStatus RowStatus } rtrConfigIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This variable uniquely identifies the interface. It is used as a cross reference in other system tables" ::= { rtrConfigIfEntry 1 } rtrConfigIfType OBJECT-TYPE SYNTAX RtrIfConfigTYPE MAX-ACCESS read-create STATUS current DESCRIPTION "This variable identifies the type of the specific entry in the rtrDynamicIfConfigTable. This field is writable only at creation time (i.e., when value of status is underCreation)." ::= { rtrConfigIfEntry 2 } rtrConfigIfName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This variable provides a logical name to a specific entry in rtrConfigIfTable. It is also used in identifying the Driver interfaces." ::= { rtrConfigIfEntry 3 } rtrConfigIfStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of the ConfigEntry. The choices are those defined in SNMPv2-TC. Only: active, createAndWait, and destroy will be used. active - The conceptual row is available for use by the managed device. createAndWait - A new instance of a conceptual row is desired, but not to have it available for use by the managed device. destroy - Delete all instances associated with an existing conceptual row." ::= { rtrConfigIfEntry 4 } -- Router Interface Configuration Table rtrIfCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrIfCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Router Interface Configuration Table." ::= { rtrInterfaces 2 } rtrIfCfgEntry OBJECT-TYPE SYNTAX RtrIfCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Router Interface Configuration Table." INDEX { rtrIfCfgIndex, rtrIfCfgIpAddress } ::= { rtrIfCfgTable 1 } RtrIfCfgEntry ::= SEQUENCE { rtrIfCfgIndex Integer32, rtrIfCfgIpAddress IpAddress, rtrIfCfgRowStatus RowStatus, rtrIfCfgIpMask IpAddress, rtrIfCfgIfIndex Integer32, rtrIfCfgType INTEGER, rtrIfCfgVlanId VlanIndex } rtrIfCfgIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the Router Interface Index. (In some cases it will be equal to the Router Interface ifIndex)." ::= { rtrIfCfgEntry 1 } rtrIfCfgIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "IP Address of the Router Interface." ::= { rtrIfCfgEntry 2 } rtrIfCfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables the user to create/delete entries of this table." ::= { rtrIfCfgEntry 3 } rtrIfCfgIpMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "IP Mask Address Router Interface." ::= { rtrIfCfgEntry 4 } rtrIfCfgIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "ifIndex of the device interface connected to this Router Interface." ::= { rtrIfCfgEntry 5 } rtrIfCfgType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), atm (2), lis (3), ethernet(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "The Router Interface Type. atm - ATM router interface lis - Logical IP Subnet router interface. ethernet - Ethernet router interface. " ::= { rtrIfCfgEntry 6 } rtrIfCfgVlanId OBJECT-TYPE SYNTAX VlanIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The VLAN ID assigned to Tagged frames transmitted from this Router Interface. The value inserted should be a defined VLAN." ::= { rtrIfCfgEntry 7 } -- **************** Interfaces Groups End ******************* -- **************** IP Groups ****************** -- IP Group -- ************************************************ -- IP Interface Configuration MIB -- ************************************************ ipSpec OBJECT IDENTIFIER ::= { radRouter 2 } rtrIpAddrTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrIpAddrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is parralel to MIB II IpAddrTable, and is used to add/delete entries to/from that table. In addition it contains private objects." ::= { ipSpec 1 } rtrIpAddrEntry OBJECT-TYPE SYNTAX RtrIpAddrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The addressing information for one of this entity's IP addresses." INDEX {rtrIpAdEntAddr} ::= { rtrIpAddrTable 1 } RtrIpAddrEntry ::= SEQUENCE { rtrIpAdEntAddr IpAddress, rtrIpAdEntIfIndex Integer32, rtrIpAdEntNetMask IpAddress, rtrIpAdEntForwardIpBroadcast INTEGER, rtrIpAdEntBackupAddr IpAddress, rtrIpAdEntStatus RowStatus } rtrIpAdEntAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address to which this entry's addressing information pertains." ::= { rtrIpAddrEntry 1 } rtrIpAdEntIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex." ::= { rtrIpAddrEntry 2 } rtrIpAdEntNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The subnet mask associated with the IP address of this entry. The value of the mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0." ::= { rtrIpAddrEntry 3 } rtrIpAdEntForwardIpBroadcast OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-create STATUS current DESCRIPTION " This variable controls forwarding of IP (sub)net-directed broadcasts destined for an attached sub(net). " DEFVAL { enable } ::= { rtrIpAddrEntry 4 } rtrIpAdEntBackupAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { rtrIpAddrEntry 5 } rtrIpAdEntStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " The Status variable is used to create and destroy a Ip Addresses." ::= { rtrIpAddrEntry 6 } icmpSpec OBJECT IDENTIFIER ::= { ipSpec 2 } rtrIcmpGenErrMsgEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable controlls the ability to generate ICMP error messages" DEFVAL { enable } ::= { icmpSpec 1 } rtrIcmpRdTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrIcmpRdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains ICMP Router Discovery parameters configurated per IP interface." ::= {icmpSpec 2} rtrIcmpRdEntry OBJECT-TYPE SYNTAX RtrIcmpRdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ICMP parameters configurated for IP interface." INDEX {rtrIcmpRdIpAddr} ::= {rtrIcmpRdTable 1} RtrIcmpRdEntry ::= SEQUENCE { rtrIcmpRdIpAddr IpAddress, rtrIcmpRdIpAdvertAddr IpAddress, rtrIcmpRdMaxAdvertInterval Integer32, rtrIcmpRdMinAdvertInterval Integer32, rtrIcmpRdAdvertLifetime Integer32, rtrIcmpRdAdvertise INTEGER, rtrIcmpRdPreferenceLevel Integer32, rtrIcmpRdEntStatus Integer32 } rtrIcmpRdIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address to which this entry's information pertains." ::= {rtrIcmpRdEntry 1} rtrIcmpRdIpAdvertAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION " The IP destination address to be used for multicast Router Advertisements sent from the interface. The only permissible values are the all-systems multicast address, 224.0.0.1, or the limited-broadcast address, 255.255.255.255." -- DEFVAL {224.0.0.1} ::= {rtrIcmpRdEntry 2} rtrIcmpRdMaxAdvertInterval OBJECT-TYPE SYNTAX Integer32 (4..1800) MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum time allowed between sending multicast Router Advertisements from the interface, in seconds. Must be no less than 4 seconds and no greater than 1800 seconds." DEFVAL {600} ::= {rtrIcmpRdEntry 3} rtrIcmpRdMinAdvertInterval OBJECT-TYPE SYNTAX Integer32 (3..1800) MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum time allowed between sending unsolicited multicast Router Advertisements from the interface, in seconds. Must be no less than 3 seconds and no greater than rtrIcmpRdMaxAdvertInterval. Default: 0.75 * rtrIcmpRdMaxAdvertInterval." ::= {rtrIcmpRdEntry 4} rtrIcmpRdAdvertLifetime OBJECT-TYPE SYNTAX Integer32 (4..9000) MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum length of time that the advertised addresses are to be considered as valid. Must be no less than rtrIcmpRdMaxAdvertInterval and no greater than 9000 seconds. Default: 3 * rtrIcmpRdMaxAdvertInterval." ::= {rtrIcmpRdEntry 5} rtrIcmpRdAdvertise OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "A flag indicating whether or not the address is to be advertised." DEFVAL {enable} ::= {rtrIcmpRdEntry 6} rtrIcmpRdPreferenceLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The preferability of the address as a default router address, relative to other router addresses on the same subnet." DEFVAL {0} ::= {rtrIcmpRdEntry 7} rtrIcmpRdEntStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Setting of any value to this object set values of all fields to the default values." ::= {rtrIcmpRdEntry 8} rip2Spec OBJECT IDENTIFIER ::= { ipSpec 3 } rtrRip2IfConfTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrRip2IfConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of rip2IfConfTable (RFC 1724 ,RIP 2). It means that every time somebody creates/destroys a row in the rip2IfConfTable, the same row should be automatically created/destroyed in this table." ::= { rip2Spec 1 } rtrRip2IfConfEntry OBJECT-TYPE SYNTAX RtrRip2IfConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table rtrRip2IfConfTable." INDEX { rtrRip2IfConfAddress } ::= { rtrRip2IfConfTable 1 } RtrRip2IfConfEntry ::= SEQUENCE { rtrRip2IfConfAddress IpAddress, rtrRip2IfConfVirtualDis Integer32, rtrRip2IfConfAutoSend INTEGER } rtrRip2IfConfAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION " The IP Address of this system on the indicated subnet. " ::= { rtrRip2IfConfEntry 1 } rtrRip2IfConfVirtualDis OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This variable defines the virtual number of hops assigned to the interface specified by rtrIfIpAddrIndex. This enables fine-tuning of the RIP routing algorithm." DEFVAL { 1 } ::= { rtrRip2IfConfEntry 2 } rtrRip2IfConfAutoSend OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "When set to enable only the default route is sent through the interface. When set to disable, regular RIPs are sent." DEFVAL { disable } ::= { rtrRip2IfConfEntry 3 } arpSpec OBJECT IDENTIFIER ::= { ipSpec 4 } rtrArpDeleteTable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to any not-null value has the effect of deleting all entries of the ARP table." ::= { arpSpec 1 } rtrArpInactiveTimeOut OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the maximum time period (in second) that can pass between ARP requests concerning an entry in the ARP table. After this time period, the entry is deleted from the table." DEFVAL { 60000 } ::= { arpSpec 2 } rtrArpProxy OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "When ARP Proxy is enabled, the router can respond to ARP requests for nodes located on a different sub-net, provided they are it its network table. The router responds with its own MAC address. When ARP Proxy is disabled, the router responds only to ARP requests for its own IP addresses." DEFVAL { disable } ::= { arpSpec 3 } -- **************************************** -- NAT Network Address Translation -- ***************************************** rtrNat OBJECT IDENTIFIER ::= { ipSpec 5 } rtrNatIfConfTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrNatIfConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of interfaces which require separate NAT configuration." ::= {rtrNat 1} rtrNatIfConfEntry OBJECT-TYPE SYNTAX RtrNatIfConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A single routing domain in a single subnet." INDEX { ifIndex, rtrNatIfVirtualAddress, rtrNatIfVirtualMask } ::= { rtrNatIfConfTable 1 } RtrNatIfConfEntry ::= SEQUENCE { rtrNatIfVirtualAddress IpAddress, rtrNatIfVirtualMask IpAddress, rtrNatIfConfStatus RowStatus, rtrNatIfRealAddress IpAddress, rtrNatIfRealMask IpAddress, rtrNatIfType INTEGER } rtrNatIfVirtualAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP Address of the virtual subnet to be translated by the 'NAT box' attached to this interface." ::= { rtrNatIfConfEntry 1 } rtrNatIfVirtualMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The subnet Mask of the virtual subnet. " ::= { rtrNatIfConfEntry 2 } rtrNatIfConfStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Writing 'destroy' has the effect of deleting this interface." ::= { rtrNatIfConfEntry 3 } rtrNatIfRealAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION " The IP Address of the real subnet which is used by 'NAT box' for translation." ::= { rtrNatIfConfEntry 4 } rtrNatIfRealMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION " The subnet Mask of the real subnet." ::= { rtrNatIfConfEntry 5 } rtrNatIfType OBJECT-TYPE SYNTAX INTEGER { static (1), dynamic (2), pat (3), transparent (4) } MAX-ACCESS read-create STATUS current DESCRIPTION "NAT type. static - Translate a specific virtual IP network to a specific real IP network. TCP, UDP and ICMP sessions originated both in real and virtual networks will be translated. dynamic - (Concurrent) Translate real IP network to larger or equal virtual IP network. TCP, UDP and ICMP sessions originated in virtual networks only can be translated and sessions originated in real networks will be rejected. A session that starts in the NAT system will be active until there will be no traffic for aging timeout period. pat - (Port Address Translation/ Single IP). Translate one real IP address to virtual IP network. TCP, UDP and ICMP sessions originated in virtual network only can be translated, sessions originated in real network will be rejected. A session that starts in the NAT system will be active until there will be no traffic for aging timeout period. transparent - In transparent mode all frames belonging to the defined IP network will be forwarded with no translation: virtual = real." ::= { rtrNatIfConfEntry 6 } -- ************************************* -- Port Address Translation -- ************************************* rtrPatTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrPatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port Address Translation (PAT - single IP NAT) configuration Table." ::= {rtrNat 2} rtrPatEntry OBJECT-TYPE SYNTAX RtrPatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry describe unique mapping between real IP address, range of ports and protocol, to local (virtual) IP address. Ports are used in the TCP (rfc793) to name the ends of logical connections which carry long term conversations. For the purpose of providing services to unknown callers, a service contact port is defined. " INDEX { rtrPatIdx } ::= { rtrPatTable 1 } RtrPatEntry ::= SEQUENCE { rtrPatIdx Integer32, rtrPatRealAddress IpAddress, rtrPatVirtualAddress IpAddress, rtrPatLowestPort Integer32, rtrPatHighestPort Integer32, rtrPatProtocol INTEGER, rtrPatStatus RowStatus } rtrPatIdx OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Running index for PAT table." ::= { rtrPatEntry 1 } rtrPatRealAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The real IP Address used for translation " ::= { rtrPatEntry 2 } rtrPatVirtualAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The virtual IP Address used for translation" ::= { rtrPatEntry 3 } rtrPatLowestPort OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Lowest Port number for this PAT entry " ::= { rtrPatEntry 4 } rtrPatHighestPort OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Highest Port number for this PAT entry " ::= { rtrPatEntry 5 } rtrPatProtocol OBJECT-TYPE SYNTAX INTEGER { tcp (6), udp (17) } MAX-ACCESS read-create STATUS current DESCRIPTION "Protocol selected. This Protocol and port range (lowest port - highest port) define the application (FTP, Telnet, SMTP etc.). Protocol enumaration numbers correspond to IP header 'protocol' field " ::= { rtrPatEntry 6 } rtrPatStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables creating and deleting entries of the table." ::= { rtrPatEntry 7 } -- ************************************************ -- FACS MIB -- ************************************************ rtrFACS OBJECT IDENTIFIER ::= { radRouter 5 } rtrFACSDefaultAction OBJECT-TYPE SYNTAX INTEGER { block(1), forward(2), blockAndReport(129) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to define the default action for the device, when no FACS statements applicable to a given frame are defined." -- DEFVAL { 1 } ::= { rtrFACS 1 } rtrFACSActTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrFACSActEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of FACS action." ::= { rtrFACS 2 } rtrFACSActEntry OBJECT-TYPE SYNTAX RtrFACSActEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each rtrFACSActEntry consist of the following parameters" INDEX {rtrFACSActType, rtrFACSActIfIndex} ::= { rtrFACSActTable 1 } RtrFACSActEntry ::= SEQUENCE { rtrFACSActType INTEGER, rtrFACSActIfIndex Integer32, rtrFACSAction INTEGER, rtrFACSActiveDB INTEGER } rtrFACSActType OBJECT-TYPE SYNTAX INTEGER { tx(1), rx(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates on which FACS Table the FACS action will preform." ::= { rtrFACSActEntry 1 } rtrFACSActIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface to which this FACS entry is applicable." ::= { rtrFACSActEntry 2 } rtrFACSAction OBJECT-TYPE SYNTAX INTEGER { none(1), eraseIP(2), eraseDECnet(3), eraseIPX(4), eraseBrg(5), replaceIP(6), replaceIPX(8), replaceBrg(9), backupIP(10), backupIPX(12), backupBrg(13) } MAX-ACCESS read-write STATUS current DESCRIPTION "The management station that sends a SET request for one of these actions with indexes rtrFACSType and rtrFACSIfIndex defines the type and the interface Id for which all FACS statements are to be erased. If no interface or no type is specified, all FACS statements for a protocol are erased." -- DEFVAL { 1 } ::= { rtrFACSActEntry 3 } rtrFACSActiveDB OBJECT-TYPE SYNTAX INTEGER { active(1), temporary(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter will point on which Facs DataBase the SNMP agent read. The Active dataBase is Read Only. The user may change FACS statements in the temporary DataBase and then write it to the Active DB." ::= { rtrFACSActEntry 4} rtrFACSTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrFACSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of FACS statment." ::= { rtrFACS 3 } rtrFACSEntry OBJECT-TYPE SYNTAX RtrFACSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each FACS statment consists of the following parameters" INDEX {rtrFACSIfIndex, rtrFACSProtocolType, rtrFACSType, rtrFACSIndex } ::= { rtrFACSTable 1 } RtrFACSEntry ::= SEQUENCE { rtrFACSIfIndex Integer32, rtrFACSProtocolType INTEGER, rtrFACSType INTEGER, rtrFACSIndex Integer32, rtrFACSSrcAdd OCTET STRING , rtrFACSSrcAddMask OCTET STRING, rtrFACSDesAdd OCTET STRING, rtrFACSDesAddMask OCTET STRING, rtrFACSOperation INTEGER, rtrFACSNetFiltering INTEGER, rtrFACSSocketNum Integer32, rtrFACSMask1Id Integer32, rtrFACSMask2Id Integer32, rtrFACSStatus INTEGER } rtrFACSIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface to which this FACS entry is applicable. For applications this variables is always 0." ::= { rtrFACSEntry 1 } rtrFACSProtocolType OBJECT-TYPE SYNTAX INTEGER{ ip(1), ipx(2), dec(3), bridge(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter define the protocol the Security Access Control is applicable." ::= { rtrFACSEntry 2 } rtrFACSType OBJECT-TYPE SYNTAX INTEGER { tx(1), rx(2), cod(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The Mode of in which this FACS statement operates. For applications this variable is always rx(2)." ::= { rtrFACSEntry 3 } rtrFACSIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Index to the FACS Table. " ::= { rtrFACSEntry 4 } rtrFACSSrcAdd OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The size of the octet string will be according to the protocol type defined in rtrFACSProtocolType." ::= { rtrFACSEntry 5 } rtrFACSSrcAddMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Source-address mask ." ::= { rtrFACSEntry 6 } rtrFACSDesAdd OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Destination-address The size of the octet string will be according to the protocol type define in rtrFACSProtocolType ." ::= { rtrFACSEntry 7 } rtrFACSDesAddMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Destination-address mask ." ::= { rtrFACSEntry 8 } rtrFACSOperation OBJECT-TYPE SYNTAX INTEGER { block(1), forward(2), permit(3), -- For Connect On demand Only deny(4), -- For Connect On demand Only blockAndReport(129) } MAX-ACCESS read-write STATUS current DESCRIPTION "... ." ::= { rtrFACSEntry 9 } rtrFACSNetFiltering OBJECT-TYPE SYNTAX INTEGER { none(1), l2multicast(2), --applicable for Bridge protocol arp(3), --applicable for ip protocol icmp(4), --applicable for ip protocol ip(5), --applicable for ip protocol udp(6), --applicable for ip protocol tcp(7), --applicable for ip protocol decnet(8), --applicable for decnet protocol ipx(9) --applicable for ipx protocol } MAX-ACCESS read-write STATUS current DESCRIPTION "... ." ::= { rtrFACSEntry 10 } rtrFACSSocketNum OBJECT-TYPE --applicable for ip,ipx protocol SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Port/socket number for different applications 0 is default meaning not applicable. none(1), ftp(21), telnet(23), smtp(25), tftp(69), snmp(161), snmpTrap(162), rip(520), sapIPX(1106), ripIPX(1107) " ::= { rtrFACSEntry 11} rtrFACSMask1Id OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Index into RND mask table FACS/COD Type) ." ::= { rtrFACSEntry 12} rtrFACSMask2Id OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Index into RND mask table FACS/COD according to the value of rtrFACSType ." ::= { rtrFACSEntry 13} rtrFACSStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) -- logically deleted } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of a table entry." ::= { rtrFACSEntry 14} rtrFACSFrameData OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Data from the frame that violated a FACS Filter." ::= { rtrFACS 4 } -- **************** FACS Group Ends ******************* -- ************************************************ -- Bridge ports Configuration MIB -- ************************************************ -- rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 } rtrBridgePortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrBridgePortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of the bridge ports" ::= { rtrBridge 1 } rtrBridgePortConfigEntry OBJECT-TYPE SYNTAX RtrBridgePortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry defines a bridge port " INDEX { rtrBridgePortCIndex } ::= { rtrBridgePortConfigTable 1 } RtrBridgePortConfigEntry ::= SEQUENCE { rtrBridgePortCIndex Integer32, rtrBridgePortCIf Integer32, rtrBridgePortCStatus RowStatus } rtrBridgePortCIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index of the bridge port. It is the same as 'dot1dBasePort' of the Bridge MIB." ::= {rtrBridgePortConfigEntry 1} rtrBridgePortCIf OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The config ifIndex the bridge port is sitting on. " ::= {rtrBridgePortConfigEntry 2} rtrBridgePortCStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of the RtrBridgePortConfigEntry. Creating and destroying the bridge port is done by this variable." ::= {rtrBridgePortConfigEntry 3} radRouterConfig OBJECT IDENTIFIER ::= { radRouter 9 } -- The Router's Configuration Table rtrConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Router's Configuration table." ::= { radRouterConfig 1 } rtrConfigEntry OBJECT-TYPE SYNTAX RtrConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Router's Configuration table." INDEX { rtrConfigIndex } ::= { rtrConfigTable 1 } RtrConfigEntry ::= SEQUENCE { rtrConfigIndex INTEGER, -- 2 is NOT used rtrConfigArpAgingTime Integer32, -- 4 is NOT used rtrConfigClassifierTosMask Integer32 } rtrConfigIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Router's Index." ::= { rtrConfigEntry 1 } -- { rtrConfigEntry 2 } is NOT used rtrConfigArpAgingTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "ARP Aging Time." ::= { rtrConfigEntry 3 } -- { rtrConfigEntry 4 } is NOT used rtrConfigClassifierTosMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Classifier's TOS Mask, as follows: 0x1C for DTR -- rfc795 0x1E for Cisco 0xE0 for Precedence -- rfc795 0xFC for Diffserv Else for Manual ." ::= { rtrConfigEntry 5 } -- { radRouterConfig 2 } is NOT used -- The Router's Forwarding Table rtrFwdTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrFwdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Router's Forwarding Table." ::= { radRouterConfig 3 } rtrFwdEntry OBJECT-TYPE SYNTAX RtrFwdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Router's Forwarding table." INDEX { rtrFwdIdx, rtrFwdIpAddress, rtrFwdIpMask, rtrFwdRuleIdx } ::= { rtrFwdTable 1 } RtrFwdEntry ::= SEQUENCE { rtrFwdIdx Integer32, rtrFwdIpAddress IpAddress, rtrFwdIpMask IpAddress, rtrFwdRuleIdx Integer32, rtrFwdRowStatus RowStatus, rtrFwdNextHop IpAddress, rtrFwdIfIndex Integer32, rtrFwdType INTEGER, rtrFwdProto INTEGER, rtrFwdEthQueue Integer32, rtrFwdMetric1 Integer32 } rtrFwdIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Router Index." ::= { rtrFwdEntry 1 } rtrFwdIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Destination IP Address." ::= { rtrFwdEntry 2 } rtrFwdIpMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Mask IP address." ::= { rtrFwdEntry 3 } rtrFwdRuleIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Rule's Number." ::= { rtrFwdEntry 4 } rtrFwdRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables the user to create/delete entries in this table. Entry of Type rtrFwdType = staticRouting(3) are created by the user. Only this type of entries can be deleted by the user. Entry of Type rtrFwdType = interface(2) are created/deleted automatically by the Agent when the user creates/deletes an interface of the Router." ::= { rtrFwdEntry 5 } rtrFwdNextHop OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the IP Address of the Next Hop." ::= { rtrFwdEntry 6 } rtrFwdIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Interface Index." ::= { rtrFwdEntry 7 } rtrFwdType OBJECT-TYPE SYNTAX INTEGER { other (1), -- not specified by this MIB reject (2), -- route which discards traffic local (3), -- local interface remote (4) -- remote destination } MAX-ACCESS read-create STATUS current DESCRIPTION "The type of route. Note that local(3) refers to a route for which the next hop is the final destination; remote(4) refers to a route for which the next hop is not the final destina- tion. Routes which do not result in traffic forwarding or rejection should not be displayed even if the implementation keeps them stored internally. reject (2) refers to a route which, if matched, discards the message as unreachable. This is used in some protocols as a means of correctly aggregating routes." ::= { rtrFwdEntry 8 } rtrFwdProto OBJECT-TYPE SYNTAX INTEGER { other (1), -- not specified local (2), -- local interface netmgmt (3), -- static route rip (8), -- Berkeley RIP or RIP-II lis (41) -- Logical IP Subnet } MAX-ACCESS read-only STATUS current DESCRIPTION "The routing mechanism via which this route was learned. Inclusion of values for gateway routing protocols is not intended to imply that hosts should support those protocols." ::= { rtrFwdEntry 9 } rtrFwdEthQueue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the ETH Queue number." ::= { rtrFwdEntry 10 } rtrFwdMetric1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The primary routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's rtrFwdProto value. If this metric is not used, its value should be set to -1." DEFVAL { -1 } ::= { rtrFwdEntry 11 } -- **************** Router Bridge Port Group Ends ******************* -- Traps rtrFACSViolation NOTIFICATION-TYPE OBJECTS { rtrFACSFrameData, rtrFACSProtocolType } STATUS current DESCRIPTION "The trap is sent for every violation of a FACS filter." ::= { radSysRtrEvents 1 } rtrSwDwnLoadTrap NOTIFICATION-TYPE OBJECTS { fileName } STATUS current DESCRIPTION "The trap is sent after the tftp download of the software and before the decompression and reset operations." ::= { radSysRtrEvents 2 } -- -- file :v:\doc\rdv\mib\ver495\atm\layer2.txt -- -- -- file: v:\doc\rdv\mib\ver495\atm\layer2.txt -- --RTR-MIB -- --Last update: 25-Sep-2002 --By: Shay Harari -- ************************************************ -- Link Layer (layer 2) MIB -- ************************************************ atmLayer2 OBJECT IDENTIFIER ::= {radAtm 7} atmLayer2XVclTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLayer2XVclEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of VCL table, which is created for each LAN VCC." ::= { atmLayer2 1 } atmLayer2XVclEntry OBJECT-TYPE SYNTAX AtmLayer2XVclEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual row in atmVclTable. This table augments the RFC2515 VCL table." AUGMENTS { atmVclEntry } ::= { atmLayer2XVclTable 1 } AtmLayer2XVclEntry ::= SEQUENCE { atmLayer2XVclConnMode INTEGER, atmLayer2XVclGroupIdx Integer32 } atmLayer2XVclConnMode OBJECT-TYPE SYNTAX INTEGER { main (1), sub (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Each valid LAN VCC is either Main or Sub. This parameter is configured only once on creation of a LAN VCC. It can not be changed after creation. In order to change the Mode, user should delete the connection and create a new one. main - A LAN VCC, which holds its own bridge port. Bridge forwarding and Bridge learning is performed only on Main VCCs. For working on a transparent bridge, that doesn't perform layer 2 priority mapping, a Main VCC should be opened, which is the default connection Mode. When working with layer 2 priority, a group of LAN VCCs should be configured, where each group will be associated with only one Main VCC. A specific Main can not be used by more than one group. sub - A LAN VCC is not part of the bridging mechanism. A Sub VCC automatically inherit some general definitions from Main VCC of its group: ATM Slot/Port and LAN Slot/Port. Max number of Sub VCCs allowed per group is: [Number of Priorities - 1]." ::= { atmLayer2XVclEntry 1 } atmLayer2XVclGroupIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The group identifier. A VCC Group identifier = 0 if the VCC was not associated with a group yet. This value is updated according to the group identifier set by atmLayer2GroupTable." ::= { atmLayer2XVclEntry 2 } atmLayer2GroupTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLayer2GroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains groups and their members. A group is a bundle of VCCs, which acts as different queues. Main and Sub VCCs should have the same ATM slot and port, and the same LAN slot and port. Each group contains: 1 to VCCs." ::= { atmLayer2 2 } atmLayer2GroupEntry OBJECT-TYPE SYNTAX AtmLayer2GroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual row in atmLayer2GroupTable. The indexes: ifIndex, atmVclVpi and atmVclVci indicate the Network ATM End-Point. Upon a group creation, one Main VCC must be added first. After the group was created, Sub VCCs may be added to the group." INDEX { atmLayer2GroupIdx, ifIndex, atmVclVpi, atmVclVci } ::= { atmLayer2GroupTable 1 } AtmLayer2GroupEntry ::= SEQUENCE { atmLayer2GroupIdx Integer32, atmLayer2GroupRowStatus RowStatus, atmLayer2GroupConnMode INTEGER, atmLayer2GroupConnPriority OCTET STRING, atmLayer2GroupName SnmpAdminString } atmLayer2GroupIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The group identifier. 0 is not a valid index." ::= { atmLayer2GroupEntry 1 } atmLayer2GroupRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table, and indication of the entry's status." ::= {atmLayer2GroupEntry 2 } atmLayer2GroupConnMode OBJECT-TYPE SYNTAX INTEGER { main (1), sub (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Each valid LAN VCC is either Main or Sub as configured in atmLayer2XVclTable." ::= { atmLayer2GroupEntry 3 } atmLayer2GroupConnPriority OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter is configured by atmLayer2PriorityRx from atmLayer2PriorityTable. Each bit in the Octet represents a specific priority as follows: MSB 7 6 5 4 3 2 1 0 LSB -> Priorities |____________________| 1 0 0 1 0 0 0 1 -> Value In this example, a certain VCC has several priorities: 0, 4 and 7." ::= { atmLayer2GroupEntry 4 } atmLayer2GroupName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (1..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "Group name. Configured by the user. The name is unique per system. For atmLayer2GroupIdx=0, the name will be null." ::= { atmLayer2GroupEntry 5 } atmLayer2PriorityTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLayer2PriorityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maps all priorities inside a group. Several priorities might be mapped to the same VCC. Upon priority change, the agent will update the VCCs of the changed priority in this table, and will update - atmLayer2GroupConnPriority parameter of both former and new owners of the changed priority. Changing a VCC value is actually a change of three parameters simultaneously: atmLayer2PriorityIfIndex, atmLayer2PriorityVclVpi and atmLayer2PriorityVclVci. Otherwise, the set will be rejected, since there might be that such VCC doesn't exist in the specific group." ::= { atmLayer2 3 } atmLayer2PriorityEntry OBJECT-TYPE SYNTAX AtmLayer2PriorityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual row in atmLayer2PriorityTable. Each entry is a Network ATM End-Point per priority. Upon a group creation, all priorities are mapped to the Main VCC. Number of entries per group is according to the number of priorities enabled. (For example, for Max priorities = 8, the agent will create 8 entries)." INDEX { atmLayer2PriorityGroupIdx, atmLayer2PriorityRx } ::= { atmLayer2PriorityTable 1 } AtmLayer2PriorityEntry ::= SEQUENCE { atmLayer2PriorityGroupIdx Integer32, atmLayer2PriorityRx INTEGER, atmLayer2PriorityIfIndex InterfaceIndex, atmLayer2PriorityVclVpi Integer32, atmLayer2PriorityVclVci Integer32 } atmLayer2PriorityGroupIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The group identifier." ::= { atmLayer2PriorityEntry 1 } atmLayer2PriorityRx OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The priority values. The used values are 0-7, but since this value is part of the index of the table, and in order to avoid '0' as an index, the index syntax is 1..8, but the real value is atmLayer2PriorityRx-1: 0 - for Low priority. 7 - for High priority." ::= { atmLayer2PriorityEntry 2 } atmLayer2PriorityIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "ATM ifIndex of the network End-Point." ::= { atmLayer2PriorityEntry 3 } atmLayer2PriorityVclVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Vpi of the network End-Point." ::= { atmLayer2PriorityEntry 4 } atmLayer2PriorityVclVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Vci of the network End-Point." ::= { atmLayer2PriorityEntry 5 } atmLayer2GroupIndexNext OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains an appropriate value to be used for atmLayer2GroupIdx when creating entries in the atmLayer2GroupTable. The value 0 indicates that no unassigned entries are available. To obtain the atmLayer2GroupIdx value for a new entry, the manager gets the current value of this object. The next index will be of the first unassigned entry. It will be provided by checking the assigned entries." ::= { atmLayer2 4 } --VLAN atmLayer2CfgTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLayer2CfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Bridge configuration Table. This table supports multi-bridge and bridge features within an ATM device." ::= { atmLayer2 5 } atmLayer2CfgEntry OBJECT-TYPE SYNTAX AtmLayer2CfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual row in atmLayer2CfgTable. Each entry in this table contains the bridging attributes for both Ethernet and ATM sides. The interface index is the Ethernet port interface. For Ace52: this object represents the Bridge ifIndex." INDEX { ifIndex } ::= { atmLayer2CfgTable 1 } AtmLayer2CfgEntry ::= SEQUENCE { atmLayer2CfgBridgingMode INTEGER, atmLayer2CfgVlanMode INTEGER, atmLayer2CfgAtmAcceptableFrameType INTEGER, atmLayer2CfgAtmIngressFiltering TruthValue, atmLayer2CfgAtmTxFrameType INTEGER, atmLayer2CfgEthAcceptableFrameType INTEGER, atmLayer2CfgBridgeAction INTEGER, atmLayer2CfgLearningMode INTEGER, atmLayer2CfgAgingTime Integer32 } atmLayer2CfgBridgingMode OBJECT-TYPE SYNTAX INTEGER { accessOnly(1), accessAndSwitching (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Bridging mode can be one of the following: ATM <> Ethernet - Bridging is between the Ethernet port and the ATM port (there is no bridging between VCs). ATM <> Ethernet + ATM - Bridging is done both between the Ethernet port and the ATM port and also between VCs." ::= { atmLayer2CfgEntry 1 } atmLayer2CfgVlanMode OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "VLAN Mode. Upon Mode changing, all LAN VCCs will be deleted by the agent from all tables that include LAN VCCs." ::= { atmLayer2CfgEntry 2 } atmLayer2CfgAtmAcceptableFrameType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), admitAll (2), admitOnlyVlanTagged (3), admitOnlyUnTagged (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Frame Type that will be acceptable by the VCCs that are associated with this Ethernet port. Frames which don't match the selected type will be discarded. admitAll - all frames will be accepted. admitOnlyVlanTagged - only Tagged frames will be accepted. admitOnlyUnTagged - only unTagged frames will be accepted." ::= { atmLayer2CfgEntry 3 } atmLayer2CfgAtmIngressFiltering OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "For the VCCs that are associated with this Ethernet port, when this is true(1) the device will discard incoming frames for VLANs which do not include this Port in its Member set. When false(2), the port will accept all incoming frames." ::= { atmLayer2CfgEntry 4 } atmLayer2CfgAtmTxFrameType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), unTagged (2), tagged (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Frame Type that will be transmitted by the VCCs that are associated with this Ethernet port. unTagged - The transmitted frames will be unTagged. tagged - The transmitted frames will be Tagged." ::= { atmLayer2CfgEntry 5 } atmLayer2CfgEthAcceptableFrameType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), admitAll (2), admitOnlyVlanTagged (3), admitOnlyUnTagged (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Frame Type that this Ethernet port will accept. (for ACE-52: the Frame Type that this Bridge will accept) This parameter is notApplicable for atmLayer2VlanMode=disable. Frames which don't match the selected type will be discarded. admitAll - all frames will be accepted. admitOnlyVlanTagged - only Tagged frames will be accepted. admitOnlyUnTagged - only unTagged frames will be accepted." ::= { atmLayer2CfgEntry 6 } atmLayer2CfgBridgeAction OBJECT-TYPE SYNTAX INTEGER { deleteLanTable (7), noOp (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables to perform the specified action on the selected port." ::= { atmLayer2CfgEntry 7 } atmLayer2CfgLearningMode OBJECT-TYPE SYNTAX INTEGER { svl (1), ivl (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the mode of the learning process of a bridge. svl - Shared VLAN process. If an individual MAC Address is learned in one VLAN, this information is used in forwarding decisions taken for that address for all other VLANs. ivl - Independent VLAN process. If an individual MAC Address is learned in one VLAN, this information is not used in forwarding decisions taken for that address for all other VLANs." ::= { atmLayer2CfgEntry 8 } atmLayer2CfgAgingTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The timeout period in seconds for aging out dynamically learned forwarding information." ::= { atmLayer2CfgEntry 9 } -- -- file :v:\doc\rdv\mib\ver470\atm\frAtm.txt -- -- -- file: v:\doc\rdv\mib\ver470\atm\frAtm.txt -- --FR-ATM-IWF-X-MIB -- --Last update: 28-Feb-2001 --By: Ilana Schvetz --atmSuPortFr OBJECT IDENTIFIER ::= { atmSuPort 4 } radAtmFr OBJECT IDENTIFIER ::= {radAtm 8} frAtmIwfXConnectionTable OBJECT-TYPE SYNTAX SEQUENCE OF FrAtmIwfXConnectionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of frAtmIwfXConnectionTable from RFC2955." ::= { radAtmFr 1 } frAtmIwfXConnectionEntry OBJECT-TYPE SYNTAX FrAtmIwfXConnectionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual row in frAtmIwfXConnectionTable. This table augments the RFC2955." AUGMENTS { frAtmIwfConnectionEntry } ::= { frAtmIwfXConnectionTable 1 } FrAtmIwfXConnectionEntry ::= SEQUENCE { frAtmIwfXConnMode INTEGER, frAtmIwfXConnSscsDlci Integer32 } frAtmIwfXConnMode OBJECT-TYPE SYNTAX INTEGER { service(1), network(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "FR IWF Mode. service - Service InterWorking (FRF.8), network - Network InterWorking (FRF.5)." ::= { frAtmIwfXConnectionEntry 1 } frAtmIwfXConnSscsDlci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter is relevant for frAtmIwfXConnMode=network (FRF.5) only. This parameter allow configuration of the FR SSCS DLCI that is transferred to the remote FR unit." ::= { frAtmIwfXConnectionEntry 2 } -- -- file :v:\doc\rdv\mib\ver495\atm\radaal5.txt -- -- -- file :v:\doc\rdv\mib\ver495\atm\radaal5.txt -- --Last update: 19-Nov-2002 by Ilana Schvetz -- ATM-X-MIB DEFINITIONS ::= BEGIN -- --atmGen OBJECT IDENTIFIER ::= {radAtm 2} --atmPerfHistory OBJECT IDENTIFIER ::= {atmGen 1} --atmIfPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 1} -- AAL5 Virtual Channel Connection Performance Statistics -- Table -- This table contains the AAL5 extension -- performance statistics of a VCC at the -- interface associated with an AAL5 entity in an ATM -- host or ATM switch. aal5VccXTable OBJECT-TYPE SYNTAX SEQUENCE OF Aal5VccXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension to AAL5 VCC Table." ::= { atmIfPerformance 4 } aal5VccXEntry OBJECT-TYPE SYNTAX Aal5VccXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This list contains the additional AAL5 VCC performance parameters and is indexed by ifIndex values of AAL5 interfaces and the associated VPI/VCI values." AUGMENTS { aal5VccEntry } ::= { aal5VccXTable 1 } Aal5VccXEntry ::= SEQUENCE { aal5VccInFrames Counter32, aal5VccOutFrames Counter32, aal5VccUnknownProtocolFrames Counter32 } aal5VccInFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received via this interface." ::= { aal5VccXEntry 1 } aal5VccOutFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames transmitted out of the interface." ::= { aal5VccXEntry 2 } aal5VccUnknownProtocolFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames that were discarded due to unsupported protocol encapsulation on this VCC." ::= { aal5VccXEntry 3 } aal5VccCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Aal5VccCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The AAL5 Current table." ::= { atmIfPerformance 5 } aal5VccCurrentEntry OBJECT-TYPE SYNTAX Aal5VccCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the AAL5 Current table." INDEX { ifIndex, aal5VccVpi, aal5VccVci } ::= { aal5VccCurrentTable 1 } Aal5VccCurrentEntry ::= SEQUENCE { aal5VccCurrentInFrames Gauge32, aal5VccCurrentOutFrames Gauge32, aal5VccCurrentUnknownProtocolFrames Gauge32, aal5VccCurrentCrcErrors Gauge32, aal5VccCurrentLengthError Gauge32, aal5VccCurrentInputCongestionDropped Gauge32, aal5VccCurrentOutputCongestionDropped Gauge32 } aal5VccCurrentInFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, encountered by the AAL5 interface in the current 15 minute interval." ::= { aal5VccCurrentEntry 1 } aal5VccCurrentOutFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames, encountered by the AAL5 interface in the current 15 minute interval." ::= { aal5VccCurrentEntry 2 } aal5VccCurrentUnknownProtocolFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of frames that were discarded due to unsupported protocol encapsulation, encountered by the AAL5 interface in the current 15 minute interval." ::= { aal5VccCurrentEntry 3 } aal5VccCurrentCrcErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of AAL5 CPCS PDUs received with CRC-32 errors, encountered by the AAL5 interface in the current 15 minute interval." ::= { aal5VccCurrentEntry 4 } aal5VccCurrentLengthError OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with length error, encountered by the AAL5 interface in the current 15 minute interval." ::= { aal5VccCurrentEntry 5 } aal5VccCurrentInputCongestionDropped OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of dropped frames due to congestion, encountered by the AAL5 interface on the Receive direction in the current 15 minute interval." ::= { aal5VccCurrentEntry 6 } aal5VccCurrentOutputCongestionDropped OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of dropped frames due to congestion, encountered by the AAL5 interface on the Transmit direction in the current 15 minute interval." ::= { aal5VccCurrentEntry 7 } -- Interval Table aal5VccIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Aal5VccIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The AAL5 Interval table." ::= { atmIfPerformance 6 } aal5VccIntervalEntry OBJECT-TYPE SYNTAX Aal5VccIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the AAL5 Interval table." INDEX { ifIndex, aal5VccVpi, aal5VccVci, aal5VccIntervalNumber } ::= { aal5VccIntervalTable 1 } Aal5VccIntervalEntry ::= SEQUENCE { aal5VccIntervalNumber Integer32, aal5VccIntervalInFrames Gauge32, aal5VccIntervalOutFrames Gauge32, aal5VccIntervalUnknownProtocolFrames Gauge32, aal5VccIntervalCrcErrors Gauge32, aal5VccIntervalLengthError Gauge32, aal5VccIntervalInputCongestionDropped Gauge32, aal5VccIntervalOutputCongestionDropped Gauge32 } aal5VccIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist)." ::= { aal5VccIntervalEntry 1 } aal5VccIntervalInFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, encountered by the AAL5 interface in one of the previous 96, individual 15 minute, intervals." ::= { aal5VccIntervalEntry 2 } aal5VccIntervalOutFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames, encountered by the AAL5 interface in in one of the previous 96, individual 15 minute, intervals." ::= { aal5VccIntervalEntry 3 } aal5VccIntervalUnknownProtocolFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of frames that were discarded due to unsupported protocol encapsulation, encountered by the AAL5 interface in one of the previous 96, individual 15 minute, intervals." ::= { aal5VccIntervalEntry 4 } aal5VccIntervalCrcErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of AAL5 CPCS PDUs received with CRC-32 errors, encountered by the AAL5 interface in one of the previous 96, individual 15 minute, intervals." ::= { aal5VccIntervalEntry 5 } aal5VccIntervalLengthError OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with length error, encountered by the AAL5 interface in one of the previous 96, individual 15 minute, intervals." ::= { aal5VccIntervalEntry 6 } aal5VccIntervalInputCongestionDropped OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of dropped frames due to a congestion, encountered by the AAL5 interface on the Receive direction in one of the previous 96, individual 15 minute, intervals" ::= { aal5VccIntervalEntry 7 } aal5VccIntervalOutputCongestionDropped OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of dropped frames due to a congestion, encountered by the AAL5 interface on the Transmit direction in one of the previous 96, individual 15 minute, intervals" ::= { aal5VccIntervalEntry 8 } -- END -- -- file :v:\doc\rdv\mib\ver495\ethif.txt -- --01/08/2000 --By: Smadar Tauber --s:\doc\rdv\mib\ver485\ethIf.txt --File: ethIf.txt --EthIf MIB - separated from mpmx.txt --diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} --Last update: 27-Jan-2003 by Shay Hararim -- -- diverseIf - diverse NON-WAN interfaces of WAN products -- --Ethernet Interface ethIf OBJECT IDENTIFIER ::= {diverseIfWanGen 1} --Ethernet Interface ethIfTable OBJECT-TYPE SYNTAX SEQUENCE OF EthIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { ethIf 1} ethIfEntry OBJECT-TYPE SYNTAX EthIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {ethIfIdx} ::= {ethIfTable 1} EthIfEntry ::= SEQUENCE { ethIfIdx Integer32, ethMode INTEGER, ethBridgingMode INTEGER, ethEncapsulationCRCMode INTEGER, ethBackPressure INTEGER, ethLimit4 INTEGER, ethSkipInitReset INTEGER, ethMulticastBlock INTEGER, ethBroadcastBlock INTEGER, ethSpeed INTEGER, ethRip2 INTEGER, ethPortPriority INTEGER, ethPortMngEnable INTEGER, ethFlowCtrlMacAddress MacAddress } ethIfIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique index of the ethernet interface/port." ::= {ethIfEntry 1} ethMode OBJECT-TYPE SYNTAX INTEGER { halfDuplex (1), fullDuplex (2), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Ethernet mode of operation." ::= {ethIfEntry 2} ethBridgingMode OBJECT-TYPE SYNTAX INTEGER { filtered (1), transparent (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the bridging mode of the Ethernet interface. " ::= {ethIfEntry 3} ethEncapsulationCRCMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), withCRC (2), withoutCRC (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object define the encapsulation type requested for the Ethernet interface. It indicates if we transfer the Ethernet frame to the other side with or without the CRC. " ::= {ethIfEntry 4} ethBackPressure OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether to enable or disable Back pressure. Back Pressure is a flow control parameter. " ::= {ethIfEntry 5} ethLimit4 OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter determine the Back off algorithm mode. Every 4 following collisions the Framer will be thrown out (4 times more than usuall)." ::= {ethIfEntry 6} ethSkipInitReset OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), notSkip (2), skip (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether read status on reset. " ::= {ethIfEntry 7} ethMulticastBlock OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), unBlock (2), block (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether to send multicast message to WAN from LAN or not. " ::= {ethIfEntry 8} ethBroadcastBlock OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), unBlock (2), block (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether to send broadcast message to WAN from LAN or not." ::= {ethIfEntry 9} ethSpeed OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), s10Mbps (2), s100Mbps (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the line speed." ::= {ethIfEntry 10} ethRip2 OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether to send RIP II message to WAN from LAN or not" ::= {ethIfEntry 11} ethPortPriority OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), fixed (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines if priority is to be considered for this Port." ::= {ethIfEntry 12} ethPortMngEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether management data can pass through this Port." ::= {ethIfEntry 13} ethFlowCtrlMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "In case of flow control - transmit frame with this specific MAC address to inform the other end to stop sending frames. Default: 01.80.C2.00.00.01." ::= {ethIfEntry 14} ethIfPerformance OBJECT IDENTIFIER ::= {ethIf 2} ethIfCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF EthIfCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ethernet Current table." ::= { ethIfPerformance 1} ethIfCurrentEntry OBJECT-TYPE SYNTAX EthIfCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Ethernet Current table." INDEX {ethIfCurrentIndex} ::= {ethIfCurrentTable 1} EthIfCurrentEntry ::= SEQUENCE { ethIfCurrentIndex Integer32, ethIfCurrentStatus OCTET STRING, ethIfCurrentInFrames Gauge32, ethIfCurrentInOctets Gauge32, ethIfCurrentAlignmentErrors Gauge32, ethIfCurrentFCSErrors Gauge32, ethIfCurrentLengthError Gauge32, ethIfCurrentOutFrames Gauge32, ethIfCurrentOutOctets Gauge32, ethIfCurrentSingleCollisionFrames Gauge32, ethIfCurrentMultipleCollisionFrames Gauge32, ethIfCurrentDeferredTransmissions Gauge32, ethIfCurrentLateCollisions Gauge32, ethIfCurrentCarrierSenseErrors Gauge32, ethIfCurrentInputCongestionDropped Gauge32, ethIfCurrentOutputCongestionDropped Gauge32 } ethIfCurrentIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Ethernet interface. It may be ifIndex." ::= { ethIfCurrentEntry 1 } ethIfCurrentStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { ethIfCurrentEntry 2 } ethIfCurrentInFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 3 } ethIfCurrentInOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received octets, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 4 } ethIfCurrentAlignmentErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, which are not complete (The result of dividing the number of bits by 8 is not an Integer), encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 5 } ethIfCurrentFCSErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames that didn't pass the FCS test, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 6 } ethIfCurrentLengthError OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with length error, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 7 } ethIfCurrentOutFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 8 } ethIfCurrentOutOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted octets, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 9 } ethIfCurrentSingleCollisionFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of successfully transmitted frames for which transmission was inhibited by exactly one collision, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 10 } ethIfCurrentMultipleCollisionFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of successfully transmitted frames for which transmission was inhibited by more than one collision, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 11 } ethIfCurrentDeferredTransmissions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames for which the first transmission attempt was delayed due to a busy media, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 12 } ethIfCurrentLateCollisions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of times that a collision was detected later than the first 64 bytes of the frame, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 13 } ethIfCurrentCarrierSenseErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 14 } ethIfCurrentInputCongestionDropped OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of frames dropped due to lack of buffers in ingress pool, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 15 } ethIfCurrentOutputCongestionDropped OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of dropped frames due to a congestion, encountered by the Transmit direction to the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 16 } --Interval Table ethIfIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF EthIfIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ethernet Interval table." ::= { ethIfPerformance 2 } ethIfIntervalEntry OBJECT-TYPE SYNTAX EthIfIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Ethernet Interval table." INDEX { ethIfIntervalIndex, ethIfIntervalNumber } ::= {ethIfIntervalTable 1} EthIfIntervalEntry ::= SEQUENCE { ethIfIntervalIndex Integer32, ethIfIntervalNumber Integer32, ethIfIntervalStatus OCTET STRING, ethIfIntervalInFrames Gauge32, ethIfIntervalInOctets Gauge32, ethIfIntervalAlignmentErrors Gauge32, ethIfIntervalFCSErrors Gauge32, ethIfIntervalLengthError Gauge32, ethIfIntervalOutFrames Gauge32, ethIfIntervalOutOctets Gauge32, ethIfIntervalSingleCollisionFrames Gauge32, ethIfIntervalMultipleCollisionFrames Gauge32, ethIfIntervalDeferredTransmissions Gauge32, ethIfIntervalLateCollisions Gauge32, ethIfIntervalCarrierSenseErrors Gauge32, ethIfIntervalInputCongestionDropped Gauge32, ethIfIntervalOutputCongestionDropped Gauge32 } ethIfIntervalIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Ethernet interface. It may be ifIndex." ::= { ethIfIntervalEntry 1 } ethIfIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist)." ::= { ethIfIntervalEntry 2 } ethIfIntervalStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { ethIfIntervalEntry 3 } ethIfIntervalInFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 4 } ethIfIntervalInOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received octets, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 5 } ethIfIntervalAlignmentErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, which are not complete (The result of dividing the number of bits by 8 is not an Integer), encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 6 } ethIfIntervalFCSErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames that didn't pass the FCS test, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 7 } ethIfIntervalLengthError OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with length error, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 8 } ethIfIntervalOutFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 9 } ethIfIntervalOutOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted octets, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 10 } ethIfIntervalSingleCollisionFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of successfully transmitted frames for which transmission was inhibited by exactly one collision, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 11 } ethIfIntervalMultipleCollisionFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of successfully transmitted frames for which transmission was inhibited by more than one collision, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 12 } ethIfIntervalDeferredTransmissions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames for which the first transmission attempt was delayed due to a busy media, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 13 } ethIfIntervalLateCollisions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of times that a collision was detected later than the first 64 bytes of the frame, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 14 } ethIfIntervalCarrierSenseErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 15 } ethIfIntervalInputCongestionDropped OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of dropped frames due to a congestion, encountered by the Receive direction to the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 16 } ethIfIntervalOutputCongestionDropped OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of dropped frames due to a congestion, encountered by the Transmit direction to the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 17 } ethPerformanceMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), countOK (2), countFail (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether OK or Fail statistics will be counted." ::= {ethIfPerformance 3} ethIfPerfTable OBJECT-TYPE SYNTAX SEQUENCE OF EthIfPerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ethernet Performance table." ::= { ethIfPerformance 4} ethIfPerfEntry OBJECT-TYPE SYNTAX EthIfPerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Ethernet Performance table." INDEX {ethIfIdx} ::= {ethIfPerfTable 1} EthIfPerfEntry ::= SEQUENCE { ethIfPerfInOkFrames Gauge32, ethIfPerfOutOkFrames Gauge32, ethIfPerfTotalCollisions Gauge32 } ethIfPerfInOkFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received OK frames, encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2) or Reset Statistics was done." ::= { ethIfPerfEntry 1 } ethIfPerfOutOkFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted OK frames, encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2) or Reset Statistics was done." ::= { ethIfPerfEntry 2 } ethIfPerfTotalCollisions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the total number of collisions of any type encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2) or Reset Statistics was done" ::= { ethIfPerfEntry 3 } -- -- file :v:\doc\rdv\mib\ver485\atm\atmCes.txt -- -- -- File: v:\doc\rdv\mib\ver485\atm\atmCes.txt -- Date: 17/01/02 -- By: Ilana Schvetz -- Last Update: 17-Jan-02 By Ilana Schvetz -- -- AAL1 statistics. An addition to ATMF-CES (ces.mib) -- atmCes OBJECT IDENTIFIER ::= {radAtm 9} atmCesPerformance OBJECT IDENTIFIER ::= {atmCes 1 } atmCesAal1CurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmCesAal1CurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The AAL1 Current table." ::= { atmCesPerformance 1 } atmCesAal1CurrentEntry OBJECT-TYPE SYNTAX AtmCesAal1CurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the AAL1 Current table." INDEX { atmCesAal1CurrentIfIndex } ::= { atmCesAal1CurrentTable 1 } AtmCesAal1CurrentEntry ::= SEQUENCE { atmCesAal1CurrentIfIndex Integer32, atmCesAal1CurrentSeqErrors Gauge32, atmCesAal1CurrentHdrErrors Gauge32, atmCesAal1CurrentPointerReframes Gauge32, atmCesAal1CurrentBufUnderflows Gauge32, atmCesAal1CurrentBufOverflows Gauge32 } atmCesAal1CurrentIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the AAL1 interface. It may be ifIndex." ::= { atmCesAal1CurrentEntry 1 } atmCesAal1CurrentSeqErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded cells due to wrong sequence number, encountered by an AAL1 interface in the current 15 minute interval." ::= { atmCesAal1CurrentEntry 2 } atmCesAal1CurrentHdrErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded cells due to bad AAL1 header error (including correctable and uncorrectable CRC, and bad parity), encountered by an AAL1 interface in the current 15 minute interval." ::= { atmCesAal1CurrentEntry 3 } atmCesAal1CurrentPointerReframes OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of events in which a SDT pointer isn't where it is expected to be, and must be reacquired, encountered by an AAL1 interface in the current 15 minute interval." ::= { atmCesAal1CurrentEntry 4 } atmCesAal1CurrentBufUnderflows OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of buffer underflow events, encountered by an AAL1 interface in the current 15 minute interval." ::= { atmCesAal1CurrentEntry 5 } atmCesAal1CurrentBufOverflows OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of buffer overflow events, encountered by an AAL1 interface in the current 15 minute interval." ::= { atmCesAal1CurrentEntry 6 } --Interval Table atmCesAal1IntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmCesAal1IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The AAL1 Interval table." ::= { atmCesPerformance 2 } atmCesAal1IntervalEntry OBJECT-TYPE SYNTAX AtmCesAal1IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the AAL1 Interval table." INDEX { atmCesAal1IntervalIfIndex, atmCesAal1IntervalNumber } ::= { atmCesAal1IntervalTable 1 } AtmCesAal1IntervalEntry ::= SEQUENCE { atmCesAal1IntervalIfIndex Integer32, atmCesAal1IntervalNumber Integer32, atmCesAal1IntervalSeqErrors Gauge32, atmCesAal1IntervalHdrErrors Gauge32, atmCesAal1IntervalPointerReframes Gauge32, atmCesAal1IntervalBufUnderflows Gauge32, atmCesAal1IntervalBufOverflows Gauge32 } atmCesAal1IntervalIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the AAL1 interface. It may be ifIndex." ::= { atmCesAal1IntervalEntry 1 } atmCesAal1IntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist)." ::= { atmCesAal1IntervalEntry 2 } atmCesAal1IntervalSeqErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded cells due to wrong sequence number, encountered by an AAL1 interface in one of the previous 96, individual 15 minute, intervals." ::= { atmCesAal1IntervalEntry 3 } atmCesAal1IntervalHdrErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded cells due to bad AAL1 header error (including correctable and uncorrectable CRC, plus bad parity), encountered by an AAL1 interface in one of the previous 96, individual 15 minute, intervals." ::= { atmCesAal1IntervalEntry 4 } atmCesAal1IntervalPointerReframes OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of events in which a SDT pointer isn't where it is expected to be, and must be reacquired, encountered by an AAL1 interface in one of the previous 96, individual 15 minute, intervals." ::= { atmCesAal1IntervalEntry 5 } atmCesAal1IntervalBufUnderflows OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of buffer underflow events, encountered by an AAL1 interface in one of the previous 96, individual 15 minute, intervals." ::= { atmCesAal1IntervalEntry 6 } atmCesAal1IntervalBufOverflows OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of buffer overflow events, encountered by an AAL1 interface in one of the previous 96, individual 15 minute, intervals." ::= { atmCesAal1IntervalEntry 7 } -- Extension for CES Configuration Table atmCesConfiguration OBJECT IDENTIFIER ::= {atmCes 2 } atmCesXConfTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmCesXConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of atmfCESConfTable table." ::= { atmCesConfiguration 1 } atmCesXConfEntry OBJECT-TYPE SYNTAX AtmCesXConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual row in atmfCESConfTable. A new row is created in this table upon each new CES VCC creation." AUGMENTS { atmfCESConfEntry } ::= { atmCesXConfTable 1 } AtmCesXConfEntry ::= SEQUENCE { atmCesXConfCBRMode INTEGER } atmCesXConfCBRMode OBJECT-TYPE SYNTAX INTEGER { normal (2), spaced (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter defines if to use Spaced or Normal CBR. Normal - TD will be allocated from the policing range (described in ACE2002 NMS SRS). The PCR is expanded with a constant value of 30 cell/sec. Spaced - TD will be allocated from the spacing range (described in ACE2002 NMS SRS). The PCR and CDVT will be expanded as described for Normal, and the CES traffic including the OAM will be spaced out at the TD's PCR. This mode is used to prevent CDVT violation due to OAM cell insertion with the CES traffic." ::= { atmCesXConfEntry 1 } -- -- file :v:\doc\rdv\mib\ver495\atm\atmRou~1.txt -- --Version: 4.95 -- --First Version Date: 12-Aug-2002 --By: Shay Harari --File: atmRouter.txt -- --Last update: 20-Oct-2002 --By: Ilana Schvetz radAtmRouter OBJECT IDENTIFIER ::= { radAtm 10 } -- Extension of the ATM Logical IP Subnet Interface Mapping Table -- ( ipoaLisIfMappingTable from RFC 2320 ) atmIpoaLisIfMappingXTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIpoaLisIfMappingXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of a table from RFC 2320: ipoaLisIfMappingTable - The ATM Logical IP Subnet Interface Mapping Table." ::= { radAtmRouter 1 } atmIpoaLisIfMappingXEntry OBJECT-TYPE SYNTAX AtmIpoaLisIfMappingXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual row in ipoaLisIfMappingTable." AUGMENTS { ipoaLisIfMappingEntry } ::= { atmIpoaLisIfMappingXTable 1 } AtmIpoaLisIfMappingXEntry ::= SEQUENCE { atmIpoaLisIfMappingType INTEGER, atmIpoaLisIfMappingIPAddress IpAddress } atmIpoaLisIfMappingType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), static(2), inAtmArp(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the Mapping Type." ::= { atmIpoaLisIfMappingXEntry 1 } atmIpoaLisIfMappingIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter is applicable for atmIpoaLisIfMappingTypeIP=static(2). This parameter is the IP Address assigned by the user when applicable." ::= { atmIpoaLisIfMappingXEntry 2 } radAtmRtrInAtmArpInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The time interval (in seconds) between sending of two InATMARP requests." ::= { radAtmRouter 2 } radAtmRtrInAtmArpAgingTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The time (in seconds) that passes until an entry is deleted, unless this entry was previously updated by a new inATMARP request or response. This variable value should be greater than the value of radAtmRtrInAtmArpInterval, so that the entry won't be deleted before an InATMARP request was sent." ::= { radAtmRouter 3 } -- clksrc.txt is the clock source table that was taken from dacs.txt for ace2002 use END