PDN-SFP-MIB DEFINITIONS ::= BEGIN ------------------------------------------------------------------- -- Copyright (C) 2003, Paradyne. All rights reserved. -- -- This MIB Enables an NMS to extract and Display information associated -- with the SFP modules. ------------------------------------------------------------------- IMPORTS Integer32, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF DisplayString, DateAndTime FROM SNMPv2-TC ifIndex FROM IF-MIB pdn-ietf-drafts FROM PDN-HEADER-MIB; pdnSfp MODULE-IDENTITY LAST-UPDATED "200304230000Z" ORGANIZATION "Paradyne Corp MIB Working Group" CONTACT-INFO "Paradyne Networks, Inc. 8545, 126th Ave. N., Largo, FL 33779 www.paradyne.com General Comments to: mibwg_team@paradyne.com Editors: Prakash Easwar" DESCRIPTION "SFP is short for Small Form-Factor Pluggable (SFP) Transceiver. They plug into an SFP Compaitble Port and allow for compact Hardware design SFP modules contain an EEPROM containing information about the part. This MIB defines objects which will allow an NMS to extract the information from the SFP modules in a MIB format. The MIB objects defined in this MIB are based on the **Small Form Factor Pluggable (SFP) Transceiver MultiSource Agreement(MSA)** Since SFP MODULES are an extension of the port itself, the ifIndex for a sfp Compatible Port will be used to access information from these modules. The Entity MIB (RFC 2737) Should Contain Entries for Each SFP Module. SFP to Port to PortIfIndex can be acheived via the Entity MIB (RFC2737)" REVISION "200304230000Z" DESCRIPTION "Added new enum to sfpEncoding MIB Object" REVISION "200302010000Z" DESCRIPTION "Initial MIB Creation" ::= { pdn-ietf-drafts 3 } sfpMIBObjects OBJECT IDENTIFIER ::= { pdnSfp 1 } sfpMIBNotifications OBJECT IDENTIFIER ::= { pdnSfp 2 } sfpMIBConformance OBJECT IDENTIFIER ::= { pdnSfp 3 } -- -- START OF sfp mib definitions -- sfpCompatibleInterfaceCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical ports in the system which are sfp compatible" ::= { sfpMIBObjects 1 } sfpInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SfpInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The sfp information table." ::= { sfpMIBObjects 2 } sfpInfoEntry OBJECT-TYPE SYNTAX SfpInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SFP Information Table" INDEX { ifIndex } ::= { sfpInfoTable 1 } SfpInfoEntry ::= SEQUENCE { sfpIdentifier INTEGER, sfpVendorSpecificIdentifier OCTET STRING, sfpExtIdentifier INTEGER, sfpConnector INTEGER, sfpVendorSpecificConnector OCTET STRING, sfpTransceiverComplianceCodes BITS, sfpFibreChannelLinkLength BITS, sfpFibreChannelTransmitterTechnology BITS, sfpFibreChannelTransmissionMedia BITS, sfpFibreChannelTransmissionSpeed BITS, sfpEncoding INTEGER, sfpBRNominal100Mbps Integer32, sfpLength9MiKm Integer32, sfpLength9Mi100M Integer32, sfpLength50Mi10M Integer32, sfpLength62Pt5Mi10M Integer32, sfpLengthCopperM Integer32, sfpVendorName DisplayString, sfpVendorOUI OCTET STRING, sfpVendorPN DisplayString, sfpVendorSN DisplayString, sfpVendorRev DisplayString, sfpLaserWavelength Integer32, sfpOptions BITS, sfpBRMin Integer32, sfpBRMax Integer32, sfpVendorDate DateAndTime, sfpVendorSpecificLotCode OCTET STRING, sfpVendorSpecificData OCTET STRING, sfpStatusCurrent BITS } sfpIdentifier OBJECT-TYPE SYNTAX INTEGER { unknown(1), gbic(2), fixed(3), sfp(4), other(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of serial transceiver unknown -- Unknown or unspecified gbic -- GBIC fixed -- Module/connector soldered to motherboard sfp -- SFP transceiver other -- Vendor specific" ::= { sfpInfoEntry 1 } sfpVendorSpecificIdentifier OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-only STATUS current DESCRIPTION "The vendor specific identifier. This Object will be set to value other than {0,0} only if sfpIdentifier returns a value of other" ::= { sfpInfoEntry 2 } sfpExtIdentifier OBJECT-TYPE SYNTAX INTEGER { unknown(1), simd(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of serial transceiver unknown -- Unknown or unspecified simd -- Serial ID module Definition" ::= { sfpInfoEntry 3 } sfpConnector OBJECT-TYPE SYNTAX INTEGER { unknown(1), sc(2), fcscc1(3), fcscc2(4), bnctnc(5), fcch(6), fiberJack(7), lc(8), mtrj(9), mu(10), sg(11), opticalPigtail(12), hssdcii(13), copperPigtail(14), other(15) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of external connector provided unknown -- Unknown or unspecified sc -- SC fcscc1 -- Fibre Channel Style 1 copper connector fcscc2 -- Fibre Channel Style 2 copper connector bnctnc -- BNC-TNC fcch -- Fibre Channel coaxial headers fiberJack -- Fiber Jack lc -- LC mtrj -- MT-RJ mu -- MU sg -- SG opticalPigtail -- Optical Pigtail hssdcii -- HSSDC II copperPigtail -- Copper Pigtail other -- Vendor specific" ::= { sfpInfoEntry 4 } sfpVendorSpecificConnector OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-only STATUS current DESCRIPTION "The type of vendor specific Connector. This Object will be set to value other than {0,0} only if sfpConnector returns a value of other" ::= { sfpInfoEntry 5 } sfpTransceiverComplianceCodes OBJECT-TYPE SYNTAX BITS { unknown(0), oc48LongReach1(1), oc48LongReach2(2), oc48LongReach3(3), oc48IntermediateReach1(4), oc48IntermediateReach2(5), oc48ShortReach(6), oc12SMLongReach1(7), oc12SMLongReach2(8), oc12SMLongReach3(9), oc12SMIntermediateReach1(10), oc12SMIntermediateReach2(11), oc12MMShortReach(12), oc3SMLongReach1(13), oc3SMLongReach2(14), oc3SMLongReach3(15), oc3SMIntermediateReach1(16), oc3SMIntermediateReach2(17), oc3MMShortReach(18), base1000T(19), base1000CX(20), base1000LX(21), base1000SX(22), sx1x(23), lx1x(24), copperActive1x(25), copperPassive1x(26) } MAX-ACCESS read-only STATUS current DESCRIPTION "The sfp transceiver codes for sonet unknown -- Unknown -- SONET Compliance Codes -- oc48LongReach1 -- OC-48, long reach, SONET LR-1 Compliant oc48LongReach2 -- OC-48, long reach, SONET LR-2 Compliant oc48LongReach3 -- OC-48, long reach, SONET LR-3 Compliant oc48IntermediateReach1 -- OC-48, intermediate reach, SONET IR-1 Compliant oc48IntermediateReach2 -- OC-48, intermediate reach, SONET IR-2 Compliant oc48ShortReach -- OC-48 short reach, SONET SR Compliant oc12SMLongReach1 -- OC-12, single mode long reach, SONET LR-1 Compliant oc12SMLongReach2 -- OC-12, single mode long reach, SONET LR-2 Compliant oc12SMLongReach3 -- OC-12, single mode long reach, SONET LR-3 Compliant oc12SMIntermediateReach1 -- OC-12, songle mode intermediate reach, SONET IR-1 Compliant oc12SMIntermediateReach2 -- OC-12, songle mode intermediate reach, SONET IR-2 Compliant oc12MMShortReach -- OC-12 multi-mode short reach, SONET SR Compliant oc3SMLongReach1 -- OC-3, single mode long reach, SONET LR-1 Compliant oc3SMLongReach2 -- OC-3, single mode long reach, SONET LR-2 Compliant oc3SMLongReach3 -- OC-3, single mode long reach, SONET LR-3 Compliant oc3SMIntermediateReach1 -- OC-3, songle mode intermediate reach, SONET IR-1 Compliant oc3SMIntermediateReach2 -- OC-3, songle mode intermediate reach, SONET IR-2 Compliant oc3MMShortReach -- OC-3 multi-mode short reach, SONET SR Compliant -- Gigabit Ethernet Compliance Codes -- base1000T -- 1000BASE-T base1000CX -- 1000BASE-CX base1000LX -- 1000BASE-LX base1000SX -- 1000BASE-SX -- Infiniband Compliance Codes -- lx1x -- 1X LX sx1x -- 1X SX copperActive1x -- 1X Copper Active copperPassive1x -- 1X Copper Passive" ::= { sfpInfoEntry 6 } sfpFibreChannelLinkLength OBJECT-TYPE SYNTAX BITS { unknown(0), veryLong(1), short(2), intermediate(3), long(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The link length for fibre unknown -- Unknown veryLong -- very long distance short -- short distance intermediate -- intermediate distance long -- long distance notFibre -- The transmission is media is not Fibre" ::= { sfpInfoEntry 7 } sfpFibreChannelTransmitterTechnology OBJECT-TYPE SYNTAX BITS { unknown(0), lc(1), el1(2), el2(3), sn(4), sl(5), ll(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The fibre channel transmitter technology unknown -- Unknown lc -- Longwave Laser el1 -- Electrical inter-enclosure el2 -- Electrical intra-enclosure sn -- Shortwave laser w/o OFC sl -- Shortwave laser w/ OFC ll -- Longwave Laser" ::= { sfpInfoEntry 8 } sfpFibreChannelTransmissionMedia OBJECT-TYPE SYNTAX BITS { unknown(0), tw(1), tp(2), mi(3), tv(4), m6(5), m5(6), sm(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The fibre channel transmitter technology unknown -- Unknown tw -- Twin Axial Pair tp -- Shielded Twisted Pair mi -- Miniature Coax tv -- Video Coax m6 -- Multi-mode, 62.5mi m5 -- Multi-mode, 50mi sm -- Single Mode" ::= { sfpInfoEntry 9 } sfpFibreChannelTransmissionSpeed OBJECT-TYPE SYNTAX BITS { unknown(0), mbps400(1), mbps200(2), mbps100(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The fibre channel transmission speed unknown -- Unknown mbps400 -- Twin Axial Pair mbps200 -- Shielded Twisted Pair mbps100 -- Miniature Coax" ::= { sfpInfoEntry 10 } sfpEncoding OBJECT-TYPE SYNTAX INTEGER { unknown(1), b8b10(2), b4b5(3), nrz(4), manchester(5), sonetScrambled(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of serial encoding that is the nominal design target of the particular SFP transceiver unknown -- Unknown or unspecified b8b10 -- 8B10B b4b5 -- 4B5B nrz -- NRZ manchester -- Manchester, sonetScrambled -- SONET Scrambled" ::= { sfpInfoEntry 11 } sfpBRNominal100Mbps OBJECT-TYPE SYNTAX Integer32 UNITS "100 Megabits per second (Mbps)" MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal bit rate(BR, nominal) which is specified in unitd of 100mbps, rounded off to the nearest 100 Mbps. The bit rate includes those bits necessary to encode and delimit the signal as well as those bits carrying data information. A value of 0 indicates that the bit rate is not specified and must be determined from the tranceiver technology. The actual information transfer rate will depend on the encoding of the data, as defined by the encoding value." ::= { sfpInfoEntry 12 } sfpLength9MiKm OBJECT-TYPE SYNTAX Integer32 UNITS "Kilometer(Km)" MAX-ACCESS read-only STATUS current DESCRIPTION "The link length that is supported by the sfp transceiver while operating in compliance with applicable standards using single mode fibre (9 micron). The value is in units of kilometers. A value of 255 means that the sfp transceiver supports a link length greater than 254 Km. A value of 0 means that the transceiver does not support single mode fibre (9 micron) or that the length information must be determined from the transceiver technology" ::= { sfpInfoEntry 13 } sfpLength9Mi100M OBJECT-TYPE SYNTAX Integer32 UNITS "100 Meters(M)" MAX-ACCESS read-only STATUS current DESCRIPTION "The link length that is supported by the sfp transceiver while operating in compliance with applicable standards using single mode fibre (9 micron).The value is in units of 100 meters. A value of 255 means that the sfp transceiver supports a link length greater than 25.4 Km. A value of 0 means that the transceiver does not support single mode fibre (9 micron) or that the length information must be determined from the transceiver technology" ::= { sfpInfoEntry 14 } sfpLength50Mi10M OBJECT-TYPE SYNTAX Integer32 UNITS "10 Meters(M)" MAX-ACCESS read-only STATUS current DESCRIPTION "The link length that is supported by the sfp transceiver while operating in compliance with applicable standards using multi-mode fibre (50 micron). The value is in units of 10 meters. A value of 255 means that the sfp transceiver supports a link length greater than 2.54 Km. A value of 0 means that the transceiver does not support multi-mode fibre (50 micron) or that the length information must be determined from the transceiver technology" ::= { sfpInfoEntry 15 } sfpLength62Pt5Mi10M OBJECT-TYPE SYNTAX Integer32 UNITS "10 Meters(M)" MAX-ACCESS read-only STATUS current DESCRIPTION "The link length that is supported by the sfp transceiver while operating in compliance with applicable standards using multi-mode fibre (62.5 micron). The value is in units of 10 meters. A value of 255 means that the sfp transceiver supports a link length greater than 2.54 Km. A value of 0 means that the transceiver does not support multi-mode fibre (62.5 micron) or that the length information must be determined from the transceiver technology" ::= { sfpInfoEntry 16 } sfpLengthCopperM OBJECT-TYPE SYNTAX Integer32 UNITS "1 Meter(M)" MAX-ACCESS read-only STATUS current DESCRIPTION "The link length that is supported by the sfp transceiver while operating in compliance with applicable standards using copper cable. The value is in units of 1 meters. A value of 255 means that the sfp transceiver supports a link length greater than 254 meters. A value of 0 means that the transceiver does not support copper cables or that the length information must be determined from the transceiver technology" ::= { sfpInfoEntry 17 } sfpVendorName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The sfp vendor name which is essentially the full name of the corporation, a commonly accepted abbreviation of the name of the corporation, the SCSI company code for the corporation, or the stock exchange code for the corporation." ::= { sfpInfoEntry 18 } sfpVendorOUI OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) MAX-ACCESS read-only STATUS current DESCRIPTION "The sfp vendor organizationally unique identifier field (vendor OUI) that contains the IEEE company identifier for the vendor. A value of all zero in the 3 octet field indicates that the vendor OUI is unspecified" ::= { sfpInfoEntry 19 } sfpVendorPN OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The sfp vendor part number (Vendor PN) or product name if the Vendor PN is unspecified, the null string {0, 0} will be returned" ::= { sfpInfoEntry 20 } sfpVendorSN OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The sfp vendor serial number (Vendor SN) if the Vendor SN is unspecified, the null string {0, 0} will be returned" ::= { sfpInfoEntry 21 } sfpVendorRev OBJECT-TYPE SYNTAX DisplayString (SIZE(0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The sfp vendor product revision number (Vendor Rev) if the Vendor Rev is unspecified, the null string {0, 0} will be returned" ::= { sfpInfoEntry 22 } sfpLaserWavelength OBJECT-TYPE SYNTAX Integer32 UNITS "Nano Meter(NM)" MAX-ACCESS read-only STATUS current DESCRIPTION "Nominal Transmitter output wavelength at room temperature." ::= { sfpInfoEntry 23 } sfpOptions OBJECT-TYPE SYNTAX BITS { unknown(0), rateSelect(1), txDisable(2), txFault(3), losNormal(5), losInverted(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The options implemented in the SFP transceiver unknown -- Unknown rateSelect -- RATE_SELECT is implemented. If this bit is not set, no control of pin is required. If this bit is set, then active control if the rate select pin is required. In Both cases, compliance with mlutiple rate standards should be determined by the following objects sfpTransceiverComplianceCodes sfpFibreChannelTransmissionSpeed txDisable -- TX_DISABLE is impelmented and disables the serial output txFault -- TX_FAULT is implemented. losNormal -- loss of signal implemented los high indicates the received optical power is below the worst case receiver sensitivity (as defined by the standard in use. los low indicates normal operation losInverted -- loss of signal implemented los low indicates the received optical power is below the worst case receiver sensitivity (as defined by the standard in use. los high indicates normal operation" ::= { sfpInfoEntry 24 } sfpBRMin OBJECT-TYPE SYNTAX Integer32 UNITS "percent below sfpBRNominal" MAX-ACCESS read-only STATUS current DESCRIPTION "The lower bit rate limit at which the SFP transceiver will meet its specifications (BR, min) is specified in units of 1% below the nominal bit rate. A value of zero indicates that this field is not specified." ::= { sfpInfoEntry 25 } sfpBRMax OBJECT-TYPE SYNTAX Integer32 UNITS "percent above sfpBRNominal" MAX-ACCESS read-only STATUS current DESCRIPTION "The upper bit rate limit at which the SFP transceiver will meet its specifications (BR, max) is specified in units of 1% above the nominal bit rate. A value of zero indicates that this field is not specified." ::= { sfpInfoEntry 26 } sfpVendorDate OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The Vendors date" ::= { sfpInfoEntry 27 } sfpVendorSpecificLotCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Vendor Specific Lot code. A value of {0, 0} indicates that the lot code is unspecified" ::= { sfpInfoEntry 28 } sfpVendorSpecificData OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Vendor Specific Information which can be read from the SFP transceiver" ::= { sfpInfoEntry 29 } sfpStatusCurrent OBJECT-TYPE SYNTAX BITS { unknown(0), notInstalled(1), installed(2), faulty(3), operational(4), enabled(5), disabled(6), inValidCCBase(7), inValidCCExt(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the sfp transceiver unknown -- Unknown notInstalled -- the SFP transceiver is not installed installed -- the sfp transceiver has been installed faulty -- the sfp transceiver is faulty operational -- the sfp transceiver is working properly enabled -- the sfp transceiver has been enabled disabled -- the sfp transceiver has been diabled, invalidCCBase -- indicates that the first 64 bytes of serial information in the SFP transceiver is invalid. The check is done by comparing the 64-th byte with the sum of the contents of the first 63 bytes (bytes 0 to 62, inclusive). invalidCCExt -- indicates that the first 32 bytes of the extended serial information in the SFP tranceiver is invalid. The check is done by comparing theu 95-th byte with the sum of the contents of the first 32 bytes (bytes 64 to 94, inclusive)." ::= { sfpInfoEntry 30 } sfpCommandTable OBJECT-TYPE SYNTAX SEQUENCE OF SfpCommandEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The sfp command table." ::= { sfpMIBObjects 3 } sfpCommandEntry OBJECT-TYPE SYNTAX SfpCommandEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SFP Command Table" INDEX { ifIndex } ::= { sfpCommandTable 1 } SfpCommandEntry ::= SEQUENCE { sfpCommand INTEGER } sfpCommand OBJECT-TYPE SYNTAX INTEGER { noCmd(1), enable(2), disable(3), reset(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This Object specifies the command to be applied to the sfp transceiver associated with a physical interface noCmd -- no command has been issued to this sfp device enable -- enables the sfp device disable -- disables the sfp device reset -- resets the sfp device when read the last command issued to the sfp device will be returned or noCmd will be returned if a command has not been issued yet" ::= { sfpCommandEntry 1 } sfpNotificationEnable OBJECT-TYPE SYNTAX BITS { faulty(0), operational(1), inserted(2), removed(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provides the ability to enable and disable notifications defined in this mib faulty indicates sfpEventFaulty notifications should be generated when the sfp is detected as being faulty operational indicates sfpEventOperational notifications should be generated when the sfp is detected as being working properly inserted indicates sfpEventInserted notifications should be generated when the sfp is insreted into a physical port removed indicates sfpEventRemoved notifications should be generated when the sfp is removed from a physical port" DEFVAL { { } } ::= { sfpMIBObjects 4 } ------------------------------------------ -- SFP Notifications ------------------------------------------ sfpNotificationsPrefix OBJECT IDENTIFIER ::= { sfpMIBNotifications 0 } sfpEventFaulty NOTIFICATION-TYPE OBJECTS { sfpStatusCurrent } STATUS current DESCRIPTION "The sfpEventFaulty notification is sent when the sfp associated with a physical port is detected as being faulty" ::= { sfpNotificationsPrefix 1 } sfpEventOperational NOTIFICATION-TYPE OBJECTS { sfpStatusCurrent } STATUS current DESCRIPTION "The sfpEventOperational notification is sent when the sfp associated with a physical port is detected as being working normally" ::= { sfpNotificationsPrefix 2 } sfpEventInserted NOTIFICATION-TYPE OBJECTS { sfpStatusCurrent } STATUS current DESCRIPTION "The sfpEventInserted notification is sent when the sfp is inserted into a physical port" ::= { sfpNotificationsPrefix 3 } sfpEventRemoved NOTIFICATION-TYPE OBJECTS { sfpStatusCurrent } STATUS current DESCRIPTION "The sfpEventRemoved notification is sent when the sfp is removed from a physical port" ::= { sfpNotificationsPrefix 4 } ------------------------------------------ -- Conformance information ------------------------------------------ sfpGroups OBJECT IDENTIFIER ::= { sfpMIBConformance 1 } sfpCompliances OBJECT IDENTIFIER ::= { sfpMIBConformance 2 } sfpReadWriteCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement configuring the sfp device." MODULE GROUP sfpCommandGroup DESCRIPTION "Implementation of this group is optional for all sfp implmentations" GROUP sfpNotificationsGroup DESCRIPTION "Implementation of this group is optional for all sfp implmentations" ::= { sfpCompliances 1 } sfpReadOnlyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement reading the SFP information." MODULE MANDATORY-GROUPS { sfpMIBObjectsGroup, sfpInformationGroup } ::= { sfpCompliances 2 } sfpNotificationCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement sfp device notifications." MODULE GROUP sfpEventGroup DESCRIPTION "Implementation of this group is optional for all sfp implmentations" ::= { sfpCompliances 3 } -- -- Units of Conformance -- sfpMIBObjectsGroup OBJECT-GROUP OBJECTS { sfpCompatibleInterfaceCount } STATUS current DESCRIPTION "A collection of scalar objects in section sfpMIBObjects providing information about sfp compatible intefaces" ::= { sfpGroups 1 } sfpInformationGroup OBJECT-GROUP OBJECTS { sfpIdentifier, sfpVendorSpecificIdentifier, sfpExtIdentifier, sfpConnector, sfpVendorSpecificConnector, sfpTransceiverComplianceCodes, sfpFibreChannelLinkLength, sfpFibreChannelTransmitterTechnology, sfpFibreChannelTransmissionMedia, sfpFibreChannelTransmissionSpeed, sfpEncoding, sfpBRNominal100Mbps, sfpLength9MiKm, sfpLength9Mi100M, sfpLength50Mi10M, sfpLength62Pt5Mi10M, sfpLengthCopperM, sfpVendorName, sfpVendorOUI, sfpVendorPN, sfpVendorSN, sfpVendorRev, sfpLaserWavelength, sfpOptions, sfpBRMin, sfpBRMax, sfpVendorDate, sfpVendorSpecificLotCode, sfpVendorSpecificData, sfpStatusCurrent } STATUS current DESCRIPTION "A collection of sfpInfoTable objects providing information applicable to sfp transceivers." ::= { sfpGroups 2 } sfpCommandGroup OBJECT-GROUP OBJECTS { sfpCommand } STATUS current DESCRIPTION "A collection of sfpCommandTable objects providing a way to issue commands to an sfp transceiver." ::= { sfpGroups 3 } sfpNotificationsGroup OBJECT-GROUP OBJECTS { sfpNotificationEnable } STATUS current DESCRIPTION "A collection of scalar objects in section sfpMIBObjects to enable/disable notifications sent by the agent" ::= { sfpGroups 4 } sfpEventGroup NOTIFICATION-GROUP NOTIFICATIONS { sfpEventFaulty, sfpEventOperational, sfpEventInserted, sfpEventRemoved } STATUS current DESCRIPTION "A collection of sfp notifications" ::= { sfpGroups 5 } END