PDN-DS1EXT-MIB DEFINITIONS ::= BEGIN ------------------------------------------------------------------- -- Copyright (C) 2002, Paradyne. All rights reserved. -- -- This MIB is an extension to the standard DS1 MIB (rfc2495). ------------------------------------------------------------------- IMPORTS MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI ifIndex FROM IF-MIB MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ent-ds1 FROM PDN-HEADER-MIB; pdnDs1Ext MODULE-IDENTITY LAST-UPDATED "200204050000Z" ORGANIZATION "Paradyne Corp MIB Working Group" CONTACT-INFO "Paradyne Networks, Inc. 8545, 126th Ave. N., Largo, FL 33779 www.paradyne.com General Comments to: mibwg_team@paradyne.com Editors: Vic Sperry" DESCRIPTION "The Paradyne enterprise DS1/G.703 extension MIB. This MIB provides additional DS1 and G.703 (E1) configuration objects not provided by rfc2495." ::= { ent-ds1 5 } pdnDs1ExtObjects OBJECT IDENTIFIER ::= { pdnDs1Ext 1 } -- -- START OF pdnDs1Ext mib definitions -- pdnDs1ExtConfTable OBJECT-TYPE SYNTAX SEQUENCE OF PdnDs1ExtConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Paradyne DS1/G.703 extension configuration table. This table is used for configuring extensions to DS1 and G.703 interfaces." ::= { pdnDs1ExtObjects 1 } pdnDs1ExtConfEntry OBJECT-TYPE SYNTAX PdnDs1ExtConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Paradyne DS1/G.703 extension configuration table. Note: The objects used depend on the type of interface. For DS1: use pdnDs1ExtConfLineLengthType and one of (pdnDs1ExtConfLineLength or pdnDs1ExtConfLineBuildOut) For G.703: use pdnDs1ExtConfLineLengthType and pdnDs1ExtConfConnector " INDEX { ifIndex } ::= { pdnDs1ExtConfTable 1 } PdnDs1ExtConfEntry ::= SEQUENCE { pdnDs1ExtConfLineLengthType INTEGER, pdnDs1ExtConfLineLength INTEGER, pdnDs1ExtConfLineBuildOut INTEGER, pdnDs1ExtConfConnector INTEGER } pdnDs1ExtConfLineLengthType OBJECT-TYPE SYNTAX INTEGER { shortHaul(1), longHaul(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the type of loop length for the interface. short-haul is intended for intra-building use. long-haul is intended for inter-building use." DEFVAL { longHaul } ::= { pdnDs1ExtConfEntry 1 } pdnDs1ExtConfLineLength OBJECT-TYPE SYNTAX INTEGER { feet000To133(1), feet134To266(2), feet267To399(3), feet400To533(4), feet534To655(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the loop length, in feet, for a short-haul DS1 line. This object only applies to DS1 interfaces. Note: This object shares a mutually exclusive relationship with the pdnDs1ExtConfLineBuildOut object i.e. only one of the two can be used for configuration at one time, based on the pdnDs1ExtConfLineLengthType object." DEFVAL { feet000To133 } ::= { pdnDs1ExtConfEntry 2 } pdnDs1ExtConfLineBuildOut OBJECT-TYPE SYNTAX INTEGER { dB0Pnt0(1), dB7Pnt5(2), dB15Pnt0(3), dB22Pnt5(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the line build out, in decibels, for a long-haul DS1 line. dB0Pnt0 = 0.0 dB dB7Pnt5 = -7.5 dB dB15Pnt0 = -15.0 dB dB22Pnt5 = -22.5 dB This object only applies to DS1 interfaces. Note: This object shares a mutually exclusive relationship with the pdnDs1ExtConfLineLength object i.e. only one of the two can be used for configuration at one time, based on the pdnDs1ExtConfLineLengthType object." DEFVAL { dB0Pnt0 } ::= { pdnDs1ExtConfEntry 3 } pdnDs1ExtConfConnector OBJECT-TYPE SYNTAX INTEGER { bnc(1), rj48(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the type of connector to be used. This object only applies to G.703 interfaces. bnc: 75-Ohm connector supporting only short-haul. rj48: 120-Ohm connector supporting both short-haul and long-haul." DEFVAL { rj48 } ::= { pdnDs1ExtConfEntry 4 } ------------------------------------------ -- Conformance information ------------------------------------------ pdnDs1ExtConformance OBJECT IDENTIFIER ::= { pdnDs1Ext 2 } pdnDs1ExtGroups OBJECT IDENTIFIER ::= { pdnDs1ExtConformance 1 } pdnDs1ExtCompliances OBJECT IDENTIFIER ::= { pdnDs1ExtConformance 2 } pdnDs1ExtCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement for using this MIB for configuring DS1 interfaces." MODULE -- this module GROUP pdnDs1ExtT1ConfigGroup DESCRIPTION "Implementation of this group is required for systems wishing to conform to this MIB for the purposes of configuring a DS1 interface." OBJECT pdnDs1ExtConfLineLengthType MIN-ACCESS read-only DESCRIPTION "The ability to set pdnDs1ExtConfLineLengthType is not required." OBJECT pdnDs1ExtConfLineLength MIN-ACCESS read-only DESCRIPTION "The ability to set pdnDs1ExtConfLineLength is not required." OBJECT pdnDs1ExtConfLineBuildOut MIN-ACCESS read-only DESCRIPTION "The ability to set pdnDs1ExtConfLineBuildOut is not required." ::= { pdnDs1ExtCompliances 1 } pdnDs1ExtG703Compliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement for using this MIB for configuring G.703 interfaces." MODULE -- this module GROUP pdnDs1ExtE1ConfigGroup DESCRIPTION "Implementation of this group is required for systems wishing to conform to this MIB for the purposes of configuring a G.703 interface." OBJECT pdnDs1ExtConfLineLengthType MIN-ACCESS read-only DESCRIPTION "The ability to set pdnDs1ExtConfLineLengthType is not required." OBJECT pdnDs1ExtConfConnector MIN-ACCESS read-only DESCRIPTION "The ability to set pdnDs1ExtConfConnector is not required." ::= { pdnDs1ExtCompliances 2 } -- -- Units of Conformance -- pdnDs1ExtT1ConfigGroup OBJECT-GROUP OBJECTS { pdnDs1ExtConfLineLengthType, pdnDs1ExtConfLineLength, pdnDs1ExtConfLineBuildOut } STATUS current -- Set as required for the group DESCRIPTION "A collection of configuration objects required for configuring a T1 interface." ::= { pdnDs1ExtGroups 1 } pdnDs1ExtE1ConfigGroup OBJECT-GROUP OBJECTS { pdnDs1ExtConfLineLengthType, pdnDs1ExtConfConnector } STATUS current -- Set as required for the group DESCRIPTION "A collection of configuration objects required for configuring a G.703 (E1) interface." ::= { pdnDs1ExtGroups 2 } END