SPEEDCARRIER-MIB DEFINITIONS ::= BEGIN --***** Version History *************************************************************** --V1.0 09.11.2006 ML: first version SPEEDCARRIER-MIB --V3.0 08.04.2009 GD: added new subtrees for multiplexer and ammplifier --V5.0 20.04.2011 ML: added SW update and config handling over Backplane -- Supported Modules: -- SPEED-DUALLINE SFP 3R -- SPEED-DUALLINE SFP 3R PROTECTION -- SPEED-DUALLINE SFP -- SPEED-SINGLELINE SFP -- SPEED-SINGLELINE XFP (SPEEDSINGLELINE-XFP-MIB) -- SPEED-SINGLELINE XFP 3R (SPEEDSINGLELINE-XFP-MIB) -- SPEED-DUALLINE FC SFP+ and XFP (SPEED-DUALLINE-FC, also 16G cards) -- SPEED-DUALLINE 10G SFP+ and XFP (obsolete. Is supported in SPEED-DUALLINE-FC) -- SPEED-AMP's (EDFA and RAMAN) (SPEED-AMP-MIB) IMPORTS DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 enterprises, IpAddress, TimeTicks, MODULE-IDENTITY FROM SNMPv2-SMI PanDacom FROM PanDacom-MIB; -- SPEEDCARRIER OBJECT IDENTIFIER ::= { PanDacom 3 } nmSPEEDCARRIER MODULE-IDENTITY LAST-UPDATED "1312120000Z" ORGANIZATION "Pan Dacom Direkt GmbH" CONTACT-INFO "Pan Dacom Direkt GmbH Dreieich Plaza 1B 63303 Dreieich Germany Tel. : +49 6103/83483-333 Fax. : +49 6103/83483-444 email: kontakt@pandacomdirekt.de web : www.pandacomdirekt.de" DESCRIPTION "Revision 2.0" REVISION "1312120000Z" -- Dec. 12, 2013 DESCRIPTION "Revision 5.2.0 - change of table indexes to slot or port - IPv6 support. So changed parameters like Trapsinks, NTP and RADIUS server address from IpAddress to DisplayString - new table for RADIUS server configs" ::= { PanDacom 3 } nmAgent OBJECT IDENTIFIER ::= { nmSPEEDCARRIER 1 } nmAgentGeneralInfo OBJECT IDENTIFIER ::= { nmAgent 1 } nmAVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "SPEED-NMS Ramdisk Version" ::= { nmAgentGeneralInfo 1 } nmASlot OBJECT-TYPE SYNTAX INTEGER (0..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot in which the SPEED-NMS card is inserted" ::= { nmAgentGeneralInfo 2 } nmADate OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "Date of the SPEED-NMS system" ::= { nmAgentGeneralInfo 3 } nmATime OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "Actual Time of the SPEED-NMS system" ::= { nmAgentGeneralInfo 4 } nmAUpTime OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "System uptime of the SPEED-NMS system" ::= { nmAgentGeneralInfo 5 } nmATemperature OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Board temperature of the SPEED-NMS system" ::= { nmAgentGeneralInfo 6 } nmAAlarmState OBJECT-TYPE SYNTAX INTEGER { noAlarms(0), activeAlarms(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm state of the SPEED-NMS system" ::= { nmAgentGeneralInfo 7 } nmASerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number of the SPEED-NMS system" ::= { nmAgentGeneralInfo 8 } nmAKernelVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "SPEED-NMS Kernel Version" ::= { nmAgentGeneralInfo 9 } --************************************************************* -- nmAgentConfig (2) nmAgentConfig OBJECT IDENTIFIER ::= { nmAgent 2 } --************************************************************* -- nmAgentConfigNetwork (1) nmAgentConfigNetwork OBJECT IDENTIFIER ::= { nmAgentConfig 1 } nmAgentConfigNetworkIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP-address of the management boards Ethernet interface" ::= { nmAgentConfigNetwork 1 } nmAgentConfigNetworkMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP-netmask of the management boards Ethernet interface" ::= { nmAgentConfigNetwork 2 } nmAgentConfigNetworkGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "default gateway of the management boards Ethernet interface" ::= { nmAgentConfigNetwork 3 } nmAgentConfigNetworkIPv6 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "IPv6-address of the management boards Ethernet interface" ::= { nmAgentConfigNetwork 5 } nmAgentConfigNetworkGatewayv6 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "default gatewayv6 of the management boards Ethernet interface" ::= { nmAgentConfigNetwork 6 } --************************************************************* -- nmAgentConfigSnmp (2) nmAgentConfigSnmp OBJECT IDENTIFIER ::= { nmAgentConfig 2 } nmAgentConfigSnmpReadCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP read community name" ::= { nmAgentConfigSnmp 1 } nmAgentConfigSnmpWriteCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP write community name" ::= { nmAgentConfigSnmp 2 } nmAgentConfigSnmpSysLocation OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "location of the SPEED-CARRIER system" ::= { nmAgentConfigSnmp 3 } nmAgentConfigSnmpSysContact OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "administrator of the SPEED-CARRIER system" ::= { nmAgentConfigSnmp 4 } nmAgentConfigSnmpTrapSink1 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "Trap destination 1 for SNMP traps. Clear value is 0.0.0.0" ::= { nmAgentConfigSnmp 5 } nmAgentConfigSnmpTrapSink2 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "Trap destination 2 for SNMP traps. Clear value is 0.0.0.0" ::= { nmAgentConfigSnmp 6 } nmAgentConfigSnmpTrapSink3 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "Trap destination 3 for SNMP traps. Clear value is 0.0.0.0" ::= { nmAgentConfigSnmp 7 } nmAgentConfigSnmpTrapSink4 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "Trap destination 4 for SNMP traps. Clear value is 0.0.0.0" ::= { nmAgentConfigSnmp 8 } nmAgentConfigSnmpTrapSink5 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "Trap destination 5 for SNMP traps. Clear value is 0.0.0.0" ::= { nmAgentConfigSnmp 9 } nmAgentConfigSnmpAgent OBJECT-TYPE SYNTAX INTEGER { off(0), snmpV1-V2c(1), snmpV3(2), notAvailable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "enable or disable the SNMP agent on the management board" ::= { nmAgentConfigSnmp 10 } -- **************************************************** nmAgentConfigSNMPv3UserConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF NMAgentConfigSNMPv3UserConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "SNMPv3 user configuration table" ::= { nmAgentConfigSnmp 11 } nmAgentConfigSNMPv3UserConfigEntry OBJECT-TYPE SYNTAX NMAgentConfigSNMPv3UserConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "SNMPv3 user configuration table" INDEX { nmAgentConfigSNMPv3UserConfigIndex } ::= { nmAgentConfigSNMPv3UserConfigTable 1 } NMAgentConfigSNMPv3UserConfigEntry ::= SEQUENCE { nmAgentConfigSNMPv3UserConfigIndex INTEGER, nmAgentConfigSnmpv3UserConfigName DisplayString, nmAgentConfigSnmpv3UserConfigUserLevel INTEGER, nmAgentConfigSnmpv3UserConfigAuthType INTEGER, nmAgentConfigSnmpv3UserConfigAuthPassPhrase DisplayString, nmAgentConfigSnmpv3UserConfigEncType INTEGER, nmAgentConfigSnmpv3UserConfigPrivPassPhrase DisplayString } nmAgentConfigSNMPv3UserConfigIndex OBJECT-TYPE SYNTAX INTEGER (0..2) MAX-ACCESS read-only STATUS current DESCRIPTION "user index" ::= { nmAgentConfigSNMPv3UserConfigEntry 1 } nmAgentConfigSnmpv3UserConfigName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "user name" ::= { nmAgentConfigSNMPv3UserConfigEntry 2 } nmAgentConfigSnmpv3UserConfigUserLevel OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), rouser(1), rwuser(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "user rights read-only (ro) or read-write (rw)" ::= { nmAgentConfigSNMPv3UserConfigEntry 3 } nmAgentConfigSnmpv3UserConfigAuthType OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), mD5(1), sHA(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "authentication types" ::= { nmAgentConfigSNMPv3UserConfigEntry 4 } nmAgentConfigSnmpv3UserConfigAuthPassPhrase OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "authentication passphrase" ::= { nmAgentConfigSNMPv3UserConfigEntry 5 } nmAgentConfigSnmpv3UserConfigEncType OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), dES(1), aES(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "privacy protocols" ::= { nmAgentConfigSNMPv3UserConfigEntry 6 } nmAgentConfigSnmpv3UserConfigPrivPassPhrase OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "privacy passphrase" ::= { nmAgentConfigSNMPv3UserConfigEntry 7 } --************************************************************* -- nmAgentConfigSlotAlarms(3) nmAgentConfigSlotAlarmsTable OBJECT-TYPE SYNTAX SEQUENCE OF NMAgentConfigSlotAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for Slot 'alarm relay' configuration" ::= { nmAgentConfig 3 } nmAgentConfigSlotAlarmsEntry OBJECT-TYPE SYNTAX NMAgentConfigSlotAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "activate or deactivate slot for 'alarm relay' configuration" INDEX { nmAgentConfigSlotAlarmsSlotNumber } ::= { nmAgentConfigSlotAlarmsTable 1 } NMAgentConfigSlotAlarmsEntry ::= SEQUENCE { nmAgentConfigSlotAlarmsSlotNumber INTEGER, nmAgentConfigSlotAlarmsInsertedCard DisplayString, nmAgentConfigSlotAlarmsConfig INTEGER } nmAgentConfigSlotAlarmsSlotNumber OBJECT-TYPE SYNTAX INTEGER (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number for alarm relay configuration" ::= { nmAgentConfigSlotAlarmsEntry 1 } nmAgentConfigSlotAlarmsInsertedCard OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Card type of inserted card in this slot" ::= { nmAgentConfigSlotAlarmsEntry 2 } nmAgentConfigSlotAlarmsConfig OBJECT-TYPE SYNTAX INTEGER { alarmsEnabled(0), alarmsDisabled(1), fail(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "set alarm reporting to 'on' or 'off' for this slot" ::= { nmAgentConfigSlotAlarmsEntry 3 } --************************************************************* -- nmAgentConfigModules (4) nmAgentConfigSlotModulesTable OBJECT-TYPE SYNTAX SEQUENCE OF NMAgentConfigSlotModulesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for card configuration" ::= { nmAgentConfig 4 } nmAgentConfigSlotModulesEntry OBJECT-TYPE SYNTAX NMAgentConfigSlotModulesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for card configuration" INDEX { nmAgentConfigModulesSlotNumber } ::= { nmAgentConfigSlotModulesTable 1 } NMAgentConfigSlotModulesEntry ::= SEQUENCE { nmAgentConfigModulesSlotNumber INTEGER, nmAgentConfigModulesInstalledCard DisplayString, nmAgentConfigModulesExpectedCard INTEGER, nmAgentConfigModulesSlotText DisplayString, nmAgentConfigModulesInstalledState DisplayString } nmAgentConfigModulesSlotNumber OBJECT-TYPE SYNTAX INTEGER (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "slot number for card configuration" ::= { nmAgentConfigSlotModulesEntry 1 } nmAgentConfigModulesInstalledCard OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Card type of inserted card in this slot" ::= { nmAgentConfigSlotModulesEntry 2 } nmAgentConfigModulesExpectedCard OBJECT-TYPE SYNTAX INTEGER { notConfigured(0), speedCWDM21(11), speedCWDM41(12), speedCWDM41E(13), speedCWDM51(14), speedCWDM81(15), speedCWDM81E(16), speedCWDM91(17), speedADCWDM(18), oneSlotPassiveCard(19), twoSlotPassiveCard(20), speedNMS(50), speedProtect3R(51), speedDuallineSfp3R(52), speedDuallineSfp(53), speedSinglelineSfp(54), speedSinglelineXFP3R(55), speedSinglelineXFP(56), speedDuallineFcXFP(57), speedDuallineFcSfp(58), speedDualline10GXFP(59), speedDualline10GSfp(60), speedDualline16GXFP(61), speedDualline16GSfp(62), speedAmpEdfaPREAMP14(101), speedAmpEdfaBOOSTER17(102), speedAmpEdfaBOOSTER17OSC(103), speedAmpEdfaBOOSTER23OSC(104), speedAmpEdfaINLINE17OSC(105), speedAmpEdfaINLINE23OSC(106), speedAmpRamanMASTER10(107), speedAmpRamanMASTER15(108), speedAmpRamanSLAVE10(109), speedAmpRamanSLAVE15(110), speedAmpRamanSTANDALONE10(111), speedAmpRamanSTANDALONE15(112), reserved(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "set the type of card, which is inserted in slot" ::= { nmAgentConfigSlotModulesEntry 3 } nmAgentConfigModulesSlotText OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "set the user defined text for passive card, which is inserted in slot" ::= { nmAgentConfigSlotModulesEntry 4 } nmAgentConfigModulesInstalledState OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Check the installed module against the expected module" ::= { nmAgentConfigSlotModulesEntry 5 } --************************************************************* -- nmAgentConfigAgentPorts (5) (for later RELEASE) -- nmAgentConfigAgentPorts OBJECT IDENTIFIER ::= { nmAgentConfig 5 } --************************************************************* -- nmAgentConfig (2) nmAgentConfigCarrierName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..60)) MAX-ACCESS read-write STATUS current DESCRIPTION "name or location of the SPEED-CARRIER system" ::= { nmAgentConfig 6 } nmAgentConfigAlarmRelay OBJECT-TYPE SYNTAX INTEGER { off(0), psu(1), fan(2), psuFan(3), slots(4), psuSlots(5), fanSlots(6), psuFanSlots(7), notAvailable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "configure alarm relay for different sources" ::= { nmAgentConfig 7 } nmAgentConfigFAN OBJECT-TYPE SYNTAX INTEGER { allOn(1), auto(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "configure fans to 'allOn' or 'auto'" ::= { nmAgentConfig 8 } nmAgentConfigNtpServer OBJECT-TYPE SYNTAX DisplayString (SIZE(0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of the Network Time Protocol server. Clear value is '0.0.0.0'." ::= { nmAgentConfig 9 } nmAgentConfigTftpServer OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), notAvailable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "enable or disable the TFTP server on the management board" ::= { nmAgentConfig 10 } nmAgentConfigWebServer OBJECT-TYPE SYNTAX INTEGER { off(0), http(1), https(2), notAvailable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "enable or disable the web server on the management board" ::= { nmAgentConfig 11 } nmAgentConfigMyWebView OBJECT-TYPE SYNTAX INTEGER { pictureAndDeviceList(1), pictureAndActiveAlarms(2), deviceListAndActiveAlarms(3), notAvailable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "configures the start screen of WebView for the web interface" ::= { nmAgentConfig 12 } nmAgentConfigPSU1Type OBJECT-TYPE SYNTAX INTEGER { slotEmpty(0), psu230VAC75W(1), psu230VAC160W(2), psu48VDC75W(3), psu48VDC150W(4), psu48VDC60W(5), psu230VAC60W(6), psu48VDC250W(7), psu230VAC250W(8), notDefined(254), notAvailable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "configures the type of PSU 1" ::= { nmAgentConfig 13 } nmAgentConfigPSU2Type OBJECT-TYPE SYNTAX INTEGER { slotEmpty(0), psu230VAC75W(1), psu230VAC160W(2), psu48VDC75W(3), psu48VDC150W(4), psu48VDC60W(5), psu230VAC60W(6), psu48VDC250W(7), psu230VAC250W(8), notDefined(254), notAvailable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "configures the type of PSU 2" ::= { nmAgentConfig 14 } nmAgentConfigTimezone OBJECT-TYPE SYNTAX INTEGER { utc(0), met(1), notAvailable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "sets the system time zone. Has only effect after reboot" ::= { nmAgentConfig 15 } nmAgentConfigAccess OBJECT-TYPE SYNTAX INTEGER { unknown(0), off(1), telnet(2), ssh2(3), sshWithPreSharedKeys(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "sets system access to telnet, SSH version 2 or off" ::= { nmAgentConfig 16 } nmAgentConfigCliTimeout OBJECT-TYPE SYNTAX INTEGER (120..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "time without user interaction before exiting CLI. Valid range 120-3600 seconds." ::= { nmAgentConfig 17 } nmAgentConfigRadiusServerAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of the radius server" ::= { nmAgentConfig 18 } nmAgentConfigRadiusStateConfig OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), useLocalPasswords(1), useRadiusAuthentication(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of the radius server" ::= { nmAgentConfig 19 } nmAgentConfigRadiusSharedSecret OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "shared secret for RADIUS server communication" ::= { nmAgentConfig 20 } nmAgentConfigNMSState OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), running(1), resetSystem(2), resetConfig(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "running state of NMS module. Reboot is NOT traffic effecting!" ::= { nmAgentConfig 21 } nmAgentConfigPSU1Text OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "configures passive text of PSU 1" ::= { nmAgentConfig 22 } nmAgentConfigPSU2Text OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "configures passive text of PSU 2" ::= { nmAgentConfig 23 } nmAgentConfigPSU3Text OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "configures passive text of PSU 3" ::= { nmAgentConfig 24 } nmAgentConfigPSU3Type OBJECT-TYPE SYNTAX INTEGER { slotEmpty(0), psu48VDC250W(7), psu230VAC250W(8), notDefined(254), notAvailable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "configures the type of PSU 3" ::= { nmAgentConfig 25 } -- **************************************************** nmAgentConfigRadiusServerConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF NMAgentConfigRadiusServerConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RADIUS server configuration table" ::= { nmAgentConfig 26 } nmAgentConfigRadiusServerConfigEntry OBJECT-TYPE SYNTAX NMAgentConfigRadiusServerConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RADIUS server configuration table" INDEX { nmAgentConfigRadiusServerConfigNumber } ::= { nmAgentConfigRadiusServerConfigTable 1 } NMAgentConfigRadiusServerConfigEntry ::= SEQUENCE { nmAgentConfigRadiusServerConfigNumber INTEGER, nmAgentConfigRadiusServerConfigIPAddress DisplayString, nmAgentConfigRadiusServerConfigSharedSecret DisplayString } nmAgentConfigRadiusServerConfigNumber OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "RADIUS server number" ::= { nmAgentConfigRadiusServerConfigEntry 1 } nmAgentConfigRadiusServerConfigIPAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "RADIUS server IPv4 or IPv6 address" ::= { nmAgentConfigRadiusServerConfigEntry 2 } nmAgentConfigRadiusServerConfigSharedSecret OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "RADIUS server shared secret" ::= { nmAgentConfigRadiusServerConfigEntry 3 } --************************************************************* nmAgentPortsStatus OBJECT IDENTIFIER ::= { nmAgent 3 } nmAgentPort1OperStatus OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), notInserted(1), up(2), down(3), txFault(4), txDisabled(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "first SFP port operational status" ::= { nmAgentPortsStatus 1 } nmAgentPort2OperStatus OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), notInserted(1), up(2), down(3), txFault(4), txDisabled(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "second SFP port operational status" ::= { nmAgentPortsStatus 2 } --************************************************************* -- nmCarrier (2) nmCarrier OBJECT IDENTIFIER ::= { nmSPEEDCARRIER 2 } --************************************************************* -- nmCarrierGerneralInfo (1) nmCarrierGerneralInfo OBJECT IDENTIFIER ::= { nmCarrier 1 } nmCarrierName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "name or location of the SPEED-CARRIER system. Allowed characters are 0-9 a-z A-Z '-' and '_'" ::= { nmCarrierGerneralInfo 1 } nmCarrierType OBJECT-TYPE SYNTAX INTEGER { unknown (0), carrier4U (1), carrier1U (2), carrier45U (3), carrier5U (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of SPEED-CARRIER system (1U / 4 slots, 4U or 4,5U with 17 slots)" ::= { nmCarrierGerneralInfo 2 } nmPSU1Status OBJECT-TYPE SYNTAX INTEGER { notInstalled (0), fail (1), temperatureWarning (2), pass (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of PSU 1" ::= { nmCarrierGerneralInfo 3 } nmPSU2Status OBJECT-TYPE SYNTAX INTEGER { notInstalled (0), fail (1), temperatureWarning (2), pass (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of PSU 2" ::= { nmCarrierGerneralInfo 4 } nmFanState OBJECT-TYPE SYNTAX INTEGER { notAvailable (0), pass (3), fail (4), notInstalled (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Fan state of the SPEED-CARRIER system" ::= { nmCarrierGerneralInfo 5 } nmCarrierPSU1Type OBJECT-TYPE SYNTAX INTEGER { notConfigured(0), psu230VAC75W(1), psu230VAC160W(2), psu48VDC75W(3), psu48VDC150W(4), psu48VDC60W(5), psu230VAC60W(6), psu48VDC250W(7), psu230VAC250W(8), notAvailable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "type of PSU 1" ::= { nmCarrierGerneralInfo 6 } nmCarrierPSU2Type OBJECT-TYPE SYNTAX INTEGER { notConfigured(0), psu230VAC75W(1), psu230VAC160W(2), psu48VDC75W(3), psu48VDC150W(4), psu48VDC60W(5), psu230VAC60W(6), psu48VDC250W(7), psu230VAC250W(8), notAvailable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "type of PSU 2" ::= { nmCarrierGerneralInfo 7 } nmCarrierPSU1Text OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "PSU 1 customer description" ::= { nmCarrierGerneralInfo 8 } nmCarrierPSU2Text OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "PSU 2 customer description" ::= { nmCarrierGerneralInfo 9 } nmCarrierPSU3Text OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "PSU 3 customer description" ::= { nmCarrierGerneralInfo 10 } nmCarrierPSU3Type OBJECT-TYPE SYNTAX INTEGER { notConfigured(0), psu230VAC75W(1), psu230VAC160W(2), psu48VDC75W(3), psu48VDC150W(4), psu48VDC60W(5), psu230VAC60W(6), psu48VDC250W(7), psu230VAC250W(8), notAvailable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "type of PSU 3" ::= { nmCarrierGerneralInfo 11 } nmPSU3Status OBJECT-TYPE SYNTAX INTEGER { notInstalled (0), fail (1), temperatureWarning (2), pass (3), notAvailable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of PSU 3" ::= { nmCarrierGerneralInfo 12 } --************************************************************* -- nmCarrierSlotOverviewTable (2) nmCarrierSlotOverviewTable OBJECT-TYPE SYNTAX SEQUENCE OF NMCarrierSlotOverviewEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Carrier slot overview table" ::= { nmCarrier 2 } nmCarrierSlotOverviewEntry OBJECT-TYPE SYNTAX NMCarrierSlotOverviewEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Carrier slot overview" INDEX { nmCarrierSlotNumber } ::= { nmCarrierSlotOverviewTable 1 } NMCarrierSlotOverviewEntry ::= SEQUENCE { nmCarrierSlotNumber INTEGER, nmCarrierSlotType DisplayString, nmCarrierSlotPassiveText DisplayString } nmCarrierSlotNumber OBJECT-TYPE SYNTAX INTEGER (1..17) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Number 1..17 for 4,xU Carrier or 1..4 for 1U Carrier" ::= { nmCarrierSlotOverviewEntry 1 } nmCarrierSlotType OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "installed card type in this slot" ::= { nmCarrierSlotOverviewEntry 2 } nmCarrierSlotPassiveText OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "user defined text for passive cards. Is only available, if passive card is configured" ::= { nmCarrierSlotOverviewEntry 3 } --************************************************************* -- nmFanOverview(3) nmFanOverviewTable OBJECT-TYPE SYNTAX SEQUENCE OF NMFanOverviewEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fan overview table" ::= { nmCarrier 3 } nmFanOverviewEntry OBJECT-TYPE SYNTAX NMFanOverviewEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fan overview table" INDEX { nmFanGroupNumber } ::= { nmFanOverviewTable 1 } NMFanOverviewEntry ::= SEQUENCE { nmFanGroupNumber INTEGER, nmFanGroupStatus INTEGER } nmFanGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Fan group number" ::= { nmFanOverviewEntry 1 } nmFanGroupStatus OBJECT-TYPE SYNTAX INTEGER { notAvailable (0), on (1), off (2), pass (3), fail (4), notInstalled (5), auto(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "For 1U Carrier group1 is the front fan and group2 the rear fan For 4.5U Carrier: group 1 and 2 are PSU 1 and 2. group 3 is the front fan below the slots and group 4 the rear fans." ::= { nmFanOverviewEntry 2 } --********************** -- nmCarrierFWUpdate(4) nmCarrierFWUpdate OBJECT IDENTIFIER ::= { nmCarrier 4 } nmCarrierFWUpdateFilename OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "filename for copying to slots" ::= { nmCarrierFWUpdate 1 } nmCarrierFirmwareTransferConfig OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), idle(1), startTransfer(2), transferReady(3), transferActive(4), transferFailure(5), abortTransfer(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Control and status of upload procedure" ::= { nmCarrierFWUpdate 2 } nmCarrierFWTransferProgress OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "copy progress in percent" ::= { nmCarrierFWUpdate 3 } nmCarrierFWUpdateConfig OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), idle(1), updateRunning(2), updateReady(3), copyToFlash(4), copyToFlashAndRestart(5), restartOnly(6), updateFailure(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "copy and activates SW-images after next restart" ::= { nmCarrierFWUpdate 4 } --********************** nmCarrierFWUpdatePolicyTable OBJECT-TYPE SYNTAX SEQUENCE OF NMCarrierFWUpdatePolicy MAX-ACCESS not-accessible STATUS current DESCRIPTION "update policy table" ::= { nmCarrier 5 } nmCarrierFWUpdatePolicyEntry OBJECT-TYPE SYNTAX NMCarrierFWUpdatePolicy MAX-ACCESS not-accessible STATUS current DESCRIPTION "update policy" INDEX { nmCarrierFWUpdatePolicySlot } ::= { nmCarrierFWUpdatePolicyTable 1 } NMCarrierFWUpdatePolicy ::= SEQUENCE { nmCarrierFWUpdatePolicySlot INTEGER, nmCarrierFWUpdatePolicyCardName DisplayString, nmCarrierFWUpdatePolicyConfig INTEGER, nmCarrierFWUpdatePolicyTransferState INTEGER } nmCarrierFWUpdatePolicySlot OBJECT-TYPE SYNTAX INTEGER (1..17) MAX-ACCESS read-only STATUS current DESCRIPTION "slot address" ::= { nmCarrierFWUpdatePolicyEntry 1 } nmCarrierFWUpdatePolicyCardName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "card name" ::= { nmCarrierFWUpdatePolicyEntry 2 } nmCarrierFWUpdatePolicyConfig OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), updatesEnabled(1), updatesDisabled(2), notApplicable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "enable or disable updates for this slot" ::= { nmCarrierFWUpdatePolicyEntry 3 } nmCarrierFWUpdatePolicyTransferState OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), idle(1), running(2), ready(3), fail(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "file transfer state" ::= { nmCarrierFWUpdatePolicyEntry 4 } --********************** nmCarrierConfigTransferTable OBJECT-TYPE SYNTAX SEQUENCE OF NMCarrierFWConfigTransfer MAX-ACCESS not-accessible STATUS current DESCRIPTION "update policy table" ::= { nmCarrier 6 } nmCarrierConfigTransferEntry OBJECT-TYPE SYNTAX NMCarrierFWConfigTransfer MAX-ACCESS not-accessible STATUS current DESCRIPTION "update policy" INDEX { nmCarrierConfigSlot } ::= { nmCarrierConfigTransferTable 1 } NMCarrierFWConfigTransfer ::= SEQUENCE { nmCarrierConfigSlot INTEGER, nmCarrierConfigModuleName DisplayString, nmCarrierConfigTransferState INTEGER, nmCarrierConfigTransfer INTEGER, nmCarrierConfigFilename DisplayString, nmCarrierConfigActivation INTEGER } nmCarrierConfigSlot OBJECT-TYPE SYNTAX INTEGER (1..17) MAX-ACCESS read-only STATUS current DESCRIPTION "Module slot index" ::= { nmCarrierConfigTransferEntry 1 } nmCarrierConfigModuleName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Module name" ::= { nmCarrierConfigTransferEntry 2 } nmCarrierConfigTransferState OBJECT-TYPE SYNTAX INTEGER { notAvailable (0), upToDate (1), fileUpdateScheduled (2), updating (3), invalidConfigFile (4), error (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "config state" ::= { nmCarrierConfigTransferEntry 3 } nmCarrierConfigTransfer OBJECT-TYPE SYNTAX INTEGER { notAvailable (0), idle(1), pushToSlot(2), updateFromSlot(3), transferReady(4), transferRunning(5), transferERROR(6), abortTransfer(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "config command for transfering files" ::= { nmCarrierConfigTransferEntry 4 } nmCarrierConfigFilename OBJECT-TYPE SYNTAX DisplayString (SIZE (0..256)) MAX-ACCESS read-write STATUS current DESCRIPTION "actual stored config file or filename to be send" ::= { nmCarrierConfigTransferEntry 5 } nmCarrierConfigActivation OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), idle(1), activating(2), ready(3), copyToFlash(4), copyToFlashAndRestart(5), restartOnly(6), failure(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "config file activation at slot" ::= { nmCarrierConfigTransferEntry 6 } --************************************************************* -- nmCarrierInventoryTable (7) nmCarrierInventoryTable OBJECT-TYPE SYNTAX SEQUENCE OF NMCarrierInventoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Carrier inventory table" ::= { nmCarrier 7 } nmCarrierInventoryEntry OBJECT-TYPE SYNTAX NMCarrierInventoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Carrier inventory" INDEX { nmCarrierInventoryIndex } ::= { nmCarrierInventoryTable 1 } NMCarrierInventoryEntry ::= SEQUENCE { nmCarrierInventoryIndex INTEGER, nmCarrierInventorySlotNumber INTEGER, nmCarrierInventoryPort DisplayString, nmCarrierInventoryModuleName DisplayString, nmCarrierInventoryPartNumber DisplayString, nmCarrierInventorySerialNumber DisplayString, nmCarrierInventoryFirmwareRelease DisplayString, nmCarrierInventoryKernelLoader DisplayString } nmCarrierInventoryIndex OBJECT-TYPE SYNTAX INTEGER (1..18000) MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory Index" ::= { nmCarrierInventoryEntry 1 } nmCarrierInventorySlotNumber OBJECT-TYPE SYNTAX INTEGER (1..17) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Number 1..17 for 4,xU Carrier or 1..4 for 1U Carrier" ::= { nmCarrierInventoryEntry 2 } nmCarrierInventoryPort OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "port number in this slot" ::= { nmCarrierInventoryEntry 3 } nmCarrierInventoryModuleName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "name of the module" ::= { nmCarrierInventoryEntry 4 } nmCarrierInventoryPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "part number" ::= { nmCarrierInventoryEntry 5 } nmCarrierInventorySerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "serial number" ::= { nmCarrierInventoryEntry 6 } nmCarrierInventoryFirmwareRelease OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "firmware release of the module" ::= { nmCarrierInventoryEntry 7 } nmCarrierInventoryKernelLoader OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Kernel/Loader version of the module" ::= { nmCarrierInventoryEntry 8 } --******************************************************************* converter OBJECT IDENTIFIER ::= { nmSPEEDCARRIER 3 } multiplexer OBJECT IDENTIFIER ::= { nmSPEEDCARRIER 4 } amplifier OBJECT IDENTIFIER ::= { nmSPEEDCARRIER 5 } convSPEEDDUALLINE OBJECT IDENTIFIER ::= { converter 1 } --******************************************************************* convSxLModuleOverviewTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLModuleOverviewEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "SPEEDDUALLINE module overview table" ::= { convSPEEDDUALLINE 1 } convSxLModuleOverviewEntry OBJECT-TYPE SYNTAX ConvSxLModuleOverviewEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Module overview entries" INDEX { convSxLMSlot } ::= { convSxLModuleOverviewTable 1 } ConvSxLModuleOverviewEntry ::= SEQUENCE { convSxLMSlot INTEGER, convSxLMDevice INTEGER, convSxLMStatus INTEGER, convSxLMSysUpTime TimeTicks, convSxLMTemp INTEGER, convSxLMAlarmState INTEGER, convSxLMBootSWVersion DisplayString, convSxLMAppSWVersion DisplayString, convSxLMHWVersion DisplayString, convSxLMPLDVersion DisplayString, convSxLMSerialNumber DisplayString } convSxLMSlot OBJECT-TYPE SYNTAX INTEGER (1..17) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot No. in Carrier" ::= { convSxLModuleOverviewEntry 2 } convSxLMDevice OBJECT-TYPE SYNTAX INTEGER { devSPEEDSINGLELINE (0), devSPEEDDUALLINE (1), devSPEEDDUALLINE3R (2), devSPEEDPROTECT3R (3), devunknown (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module DeviceType" ::= { convSxLModuleOverviewEntry 3 } convSxLMStatus OBJECT-TYPE SYNTAX INTEGER { running (0), resetHardware (1), resetConfig (2), resetCAN (3), resetSoftware (4), unknown (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Status of inserted module. resetSoftware does not affect traffic" ::= { convSxLModuleOverviewEntry 4 } convSxLMSysUpTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "System uptime in seconds" ::= { convSxLModuleOverviewEntry 5 } convSxLMTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Module temperature" ::= { convSxLModuleOverviewEntry 6 } convSxLMAlarmState OBJECT-TYPE SYNTAX INTEGER { noAlarm (0), activeAlarms (1), unknown (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module alarm states, if they are active see Event-Table" ::= { convSxLModuleOverviewEntry 7 } convSxLMBootSWVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "Module bootloader software version" ::= { convSxLModuleOverviewEntry 8 } convSxLMAppSWVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "Module application software Version" ::= { convSxLModuleOverviewEntry 9 } convSxLMHWVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "Module board hardware version" ::= { convSxLModuleOverviewEntry 10 } convSxLMPLDVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "Module firmware version" ::= { convSxLModuleOverviewEntry 11 } convSxLMSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "Modules serial number" ::= { convSxLModuleOverviewEntry 12 } --************************Table************************************** convSxLSWImagesOverviewTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLSWImagesOverviewEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "SPEEDDUALLINE software images Overview Table" ::= { convSPEEDDUALLINE 2 } convSxLSWImagesOverviewEntry OBJECT-TYPE SYNTAX ConvSxLSWImagesOverviewEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Module overview entries" INDEX { convSxLSWSlot } ::= { convSxLSWImagesOverviewTable 1 } ConvSxLSWImagesOverviewEntry ::= SEQUENCE { convSxLSWSlot INTEGER, convSxLSWBootImage DisplayString, convSxLSWAppImage1 DisplayString, convSxLSWAppImage2 DisplayString, convSxLSWUploadStatus INTEGER, convSxLSWUpdateStatus INTEGER } convSxLSWSlot OBJECT-TYPE SYNTAX INTEGER (1..17) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot No. in Carrier" ::= { convSxLSWImagesOverviewEntry 2 } convSxLSWBootImage OBJECT-TYPE SYNTAX DisplayString (SIZE (0..36)) MAX-ACCESS read-only STATUS current DESCRIPTION "Identification of bootimage" ::= { convSxLSWImagesOverviewEntry 3 } convSxLSWAppImage1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..36)) MAX-ACCESS read-only STATUS current DESCRIPTION "Identification of application image1" ::= { convSxLSWImagesOverviewEntry 4 } convSxLSWAppImage2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..36)) MAX-ACCESS read-only STATUS current DESCRIPTION "Identification of application image2" ::= { convSxLSWImagesOverviewEntry 5 } convSxLSWUploadStatus OBJECT-TYPE SYNTAX INTEGER { ready (0), startUpload (1), uploadActive (2), uploadFailure (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Control and status of upload procedure" ::= { convSxLSWImagesOverviewEntry 6 } convSxLSWUpdateStatus OBJECT-TYPE SYNTAX INTEGER { idle (0), activateImage1 (1), activateImage2 (2), invalidImages (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "activates SW-image after next reset" ::= { convSxLSWImagesOverviewEntry 7 } --************************Table************************************** convSxLModuleConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLModuleConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "SPEEDDUALLINE config table" ::= { convSPEEDDUALLINE 3 } convSxLModuleConfigEntry OBJECT-TYPE SYNTAX ConvSxLModuleConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Module config entries" INDEX { convSxLMSlot } ::= { convSxLModuleConfigTable 1 } ConvSxLModuleConfigEntry ::= SEQUENCE { convSxLMSlot INTEGER, convSxLMIpAddress IpAddress, convSxLMIpNetmask IpAddress, convSxLMIpGateway IpAddress, convSxLMIpTftpServer IpAddress, convSxLMIpTrapSink IpAddress, convSxLMSNMPReadCommunity DisplayString, convSxLMSNMPWriteCommunity DisplayString, convSxLMTempWarningLevel INTEGER, convSxLMTempAlarmLevel INTEGER, convSxLMAlarmReport INTEGER, convSxLMEthPortConfig INTEGER, convSxLMEthPortState INTEGER, convSxLMCliUserTimeout INTEGER } convSxLMIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Module IP address" ::= { convSxLModuleConfigEntry 3 } convSxLMIpNetmask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Module netmask" ::= { convSxLModuleConfigEntry 4 } convSxLMIpGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Default gateway" ::= { convSxLModuleConfigEntry 5 } convSxLMIpTftpServer OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "TFTP server address for SW-Update" ::= { convSxLModuleConfigEntry 6 } convSxLMIpTrapSink OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "SNMP TrapSink-address" ::= { convSxLModuleConfigEntry 7 } convSxLMSNMPReadCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "SNMP ReadCommunity" ::= { convSxLModuleConfigEntry 8 } convSxLMSNMPWriteCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "SNMP WriteCommunity" ::= { convSxLModuleConfigEntry 9 } convSxLMTempWarningLevel OBJECT-TYPE SYNTAX INTEGER(0..60) MAX-ACCESS read-write STATUS current DESCRIPTION "Warning level for module ambient temperature (0 - 60 degree Celsius)" ::= { convSxLModuleConfigEntry 10 } convSxLMTempAlarmLevel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm level for module ambient temperature" ::= { convSxLModuleConfigEntry 11 } convSxLMAlarmReport OBJECT-TYPE SYNTAX INTEGER { disable (0), toNMA (1), toETH (2), toNMAandETH (3), notavailable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Controls alarm signaling modes of module" ::= { convSxLModuleConfigEntry 12 } convSxLMEthPortConfig OBJECT-TYPE SYNTAX INTEGER { unknown (0), portDown (1), portUp (2), notavailable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Module Ethernet Port config" ::= { convSxLModuleConfigEntry 13 } convSxLMEthPortState OBJECT-TYPE SYNTAX INTEGER { unknown (0), portDown (1), portUp (2), notavailable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module Ethernet Port state" ::= { convSxLModuleConfigEntry 14 } convSxLMCliUserTimeout OBJECT-TYPE SYNTAX INTEGER(120..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "Module CLI User Timeout" ::= { convSxLModuleConfigEntry 15 } --************************Table************************************** convSxLModuleProtectionTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLModuleProtectionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "SPEEDDUALLINE protection table" ::= { convSPEEDDUALLINE 4 } convSxLModuleProtectionEntry OBJECT-TYPE SYNTAX ConvSxLModuleProtectionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Protection table entries" INDEX { convSxLMSlot } ::= { convSxLModuleProtectionTable 1 } ConvSxLModuleProtectionEntry ::= SEQUENCE { convSxLMSlot INTEGER, convSxLMLinkProtectionConfig INTEGER, convSxLMLinkProtectionStatus INTEGER, convSxLMLinkProtectionFallback INTEGER } convSxLMLinkProtectionConfig OBJECT-TYPE SYNTAX INTEGER { unknown(0), fallbackPort1(1), fallbackPort2(2), staticPort1(3), staticPort2(4), protectionOFF(5), notAvailable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Status of protection module" ::= { convSxLModuleProtectionEntry 3 } convSxLMLinkProtectionStatus OBJECT-TYPE SYNTAX INTEGER { unknown(0), port1active(1), port2active(2), testing(3), noneActive(4), notAvailable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of protection functionality regarding the link port. The link port are always port1 (main) and port2 (backup). The local port is port4" ::= { convSxLModuleProtectionEntry 4 } convSxLMLinkProtectionFallback OBJECT-TYPE SYNTAX INTEGER(5..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Fallback time of errorfree seconds before switching back to MainPath. If there is an error during the Fallback-Time the timer will be restarted again" ::= { convSxLModuleProtectionEntry 5 } --************************Table************************************** convSxLPortOverviewTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLPortOverviewEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port status table" ::= { convSPEEDDUALLINE 5 } convSxLPortOverviewEntry OBJECT-TYPE SYNTAX ConvSxLPortOverviewEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port status entries" INDEX { convSxLPortIndex } ::= { convSxLPortOverviewTable 1 } ConvSxLPortOverviewEntry ::= SEQUENCE { convSxLPortIndex INTEGER, convSxLSlot INTEGER, convSxLPort INTEGER, convSxLDescription DisplayString, convSxLAdminState INTEGER, convSxLOperState INTEGER, convSxLAlarmState INTEGER, convSxLSFPState INTEGER, convSxLLLCFState INTEGER, convSxLLoopState INTEGER, convSxLSpeed INTEGER, convSxLTxPortConnection INTEGER, convSxLDMIState INTEGER } convSxLPortIndex OBJECT-TYPE SYNTAX INTEGER (1..1800) MAX-ACCESS read-only STATUS current DESCRIPTION "Port Index" ::= { convSxLPortOverviewEntry 1 } convSxLSlot OBJECT-TYPE SYNTAX INTEGER (1..17) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number" ::= { convSxLPortOverviewEntry 2 } convSxLPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Port number" ::= { convSxLPortOverviewEntry 3 } convSxLDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) MAX-ACCESS read-write STATUS current DESCRIPTION "Port desription string" ::= { convSxLPortOverviewEntry 4 } convSxLAdminState OBJECT-TYPE SYNTAX INTEGER { adminDown (0), adminUp (1), notAvailable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Port configuration mode" ::= { convSxLPortOverviewEntry 5 } convSxLOperState OBJECT-TYPE SYNTAX INTEGER { down(0), up(1), loop(2), downLLCF(3), downTxFault(4), downRxLevel(5), downTxLevel(6), notAvailable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Port operational state" ::= { convSxLPortOverviewEntry 6 } convSxLSFPState OBJECT-TYPE SYNTAX INTEGER { sfpRemoved (0), sfpInstalled (1), sfpTxFault (2), notAvailable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "SFP-Port state" ::= { convSxLPortOverviewEntry 7 } convSxLLLCFState OBJECT-TYPE SYNTAX INTEGER { off (0), on (1), notAvailable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of linkloss configuration" ::= { convSxLPortOverviewEntry 8 } convSxLLoopState OBJECT-TYPE SYNTAX INTEGER { off (0), on (1), notAvailable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of loop configuration" ::= { convSxLPortOverviewEntry 9 } convSxLSpeed OBJECT-TYPE SYNTAX INTEGER { speedTransparent (0), speedSTM1-155Mbit (1), speedSTM4-622Mbit (2), speedSTM16-2488Mbit (3), sSTM16FEC2666Mbit (4), sFastEthernet125Mbit (5), sGigabitEthernet1250Mbit (6), sFibreChannel133Mbit (7), sFibreChannel266Mbit (8), sFibreChannel531Mbit (9), sFibreChannel1062Mbit (10), sFibreChannel2125Mbit (11), sESCON200Mbit (12), notAvailable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "TxPort 3R regeneration speed and protocol" ::= { convSxLPortOverviewEntry 10 } convSxLTxPortConnection OBJECT-TYPE SYNTAX INTEGER { notConnected (0), toPort1 (1), toPort2 (2), toPort3 (3), toPort4 (4), notAvailable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of port to port connection" ::= { convSxLPortOverviewEntry 11 } convSxLAlarmState OBJECT-TYPE SYNTAX INTEGER { noAlarm (0), alarmLOS (1), alarmCDR (2), alarmTxFault (3), alarmRxLevel (4), warningRxLevel (5), warningTxLevel (6), activeAlarms (16), activeWarnigs (32), notAvailable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Port warning / alarm states" ::= { convSxLPortOverviewEntry 12 } convSxLDMIState OBJECT-TYPE SYNTAX INTEGER { notAvailable (0), sff-8472Rev9-3 (1), sff-8472Rev9-4 (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Availability or version of Diagnostic Monitoring Information (DMI)" ::= { convSxLPortOverviewEntry 13 } --************************Table************************************** convSxLPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port config table" ::= { convSPEEDDUALLINE 6 } convSxLPortConfigEntry OBJECT-TYPE SYNTAX ConvSxLPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port config entry" INDEX { convSxLPortIndex } ::= { convSxLPortConfigTable 1 } ConvSxLPortConfigEntry ::= SEQUENCE { convSxLPortIndex INTEGER, convSxLSlot INTEGER, convSxLPort INTEGER, convSxLAdminConfig INTEGER, convSxLLLCFConfig INTEGER, convSxLLoopConfig INTEGER, convSxLSpeedConfig INTEGER, convSxLPortConnection INTEGER, convSxLPortAlarmDeactivation INTEGER, convSxLPortAlarmSchedule INTEGER } convSxLAdminConfig OBJECT-TYPE SYNTAX INTEGER { adminDown (0), adminUp (1), notAvailable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Admin configuration of a specific port" ::= { convSxLPortConfigEntry 4 } convSxLLLCFConfig OBJECT-TYPE SYNTAX INTEGER { off (0), on (1), notAvailable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configuration of Link Loss Carry Forward (LLCF) function. If a link down event occurs on the link port the local port will be disabled to signal the error state to the locally connected device e.g. router" ::= { convSxLPortConfigEntry 5 } convSxLLoopConfig OBJECT-TYPE SYNTAX INTEGER { off (0), on (1), notAvailable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setup of loops. After a reset, all loops will be switched off" ::= { convSxLPortConfigEntry 6 } convSxLSpeedConfig OBJECT-TYPE SYNTAX INTEGER { speedTransparent (0), speedSTM1-155Mbit (1), speedSTM4-622Mbit (2), speedSTM16-2488Mbit (3), sSTM16FEC2666Mbit (4), sFastEthernet125Mbit (5), sGigabitEthernet1250Mbit (6), sFibreChannel133Mbit (7), sFibreChannel266Mbit (8), sFibreChannel531Mbit (9), sFibreChannel1062Mbit (10), sFibreChannel2125Mbit (11), sESCON200Mbit (12), sVIDEO143Mbit (13), sVIDEO177Mbit (14), sVIDEO270Mbit (15), sVIDEO360Mbit (16), sVIDEO540Mbit (17), sVIDEO1001Mbit (18), sVIDEO1485Mbit (19), sVIDEO2970Mbit (20), notAvailable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "TxPort 3R regeneration speed and protocol" ::= { convSxLPortConfigEntry 7 } convSxLPortConnection OBJECT-TYPE SYNTAX INTEGER { noConnection (0), fromPort1 (1), fromPort2 (2), fromPort3 (3), fromPort4 (4), notPossible (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setup of connections. toPortx means a connection between Rx-input to Tx-output" ::= { convSxLPortConfigEntry 8 } convSxLPortAlarmDeactivation OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), alarmReportingEnabled(1), alarmReportingDisabledbySchedule(2), alarmReportingDisabledPermanent(3), unknown(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Port alarm deactivation schedule" ::= { convSxLPortConfigEntry 9 } convSxLPortAlarmSchedule OBJECT-TYPE SYNTAX INTEGER (0..1200) MAX-ACCESS read-write STATUS current DESCRIPTION "Port alarm deactivation schedule. Value in hours. After this time has elapsed, the alarms are active again. Valid range: 1..1200. 0 means less then 1 hour" ::= { convSxLPortConfigEntry 10 } --******************************************************************* convSxSFPIdentifikation OBJECT IDENTIFIER ::= { convSPEEDDUALLINE 7 } --************************Table************************************** convSXLSFPDescriptionTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSXLSFPDescriptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Optical transceiver parameter table" ::= { convSxSFPIdentifikation 1 } convSXLSFPDescriptionEntry OBJECT-TYPE SYNTAX ConvSXLSFPDescriptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Talbe entries" INDEX { convSxLPortIndex } ::= { convSXLSFPDescriptionTable 1 } ConvSXLSFPDescriptionEntry ::= SEQUENCE { convSxLPortIndex INTEGER, convSxLSlot INTEGER, convSxLPort INTEGER, convSxLSFPVendor DisplayString, convSxLSFPVendorOUI DisplayString, convSxLSFPVendorCode DisplayString, convSxLSFPVendorRevisionCode DisplayString, convSxLSFPVendorDateCode DisplayString, convSxLSFPVendorSerialNumber DisplayString, convSxLSFPType INTEGER, convSxLSFPConnector INTEGER, convSxLSFPWavelength DisplayString } convSxLSFPVendor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "SFP vendor name" ::= { convSXLSFPDescriptionEntry 4 } convSxLSFPVendorOUI OBJECT-TYPE SYNTAX DisplayString (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "Vendor specific IEEE-OUI" ::= { convSXLSFPDescriptionEntry 5 } convSxLSFPVendorCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "Part identification code, vendor specific" ::= { convSXLSFPDescriptionEntry 6 } convSxLSFPVendorRevisionCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..5)) MAX-ACCESS read-only STATUS current DESCRIPTION "Parts revision code, vendor specific" ::= { convSXLSFPDescriptionEntry 7 } convSxLSFPVendorDateCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..9)) MAX-ACCESS read-only STATUS current DESCRIPTION "The vendor date code for the transceiver. The date code is specified in the following format: YYYY.MM.DD/LL; YYYY = year; MM = month; DD = day of month; LL = vendor lot code" ::= { convSXLSFPDescriptionEntry 8 } convSxLSFPVendorSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "Parts serial number " ::= { convSXLSFPDescriptionEntry 9 } convSxLSFPType OBJECT-TYPE SYNTAX INTEGER { unspecified (0), tGBIC (1), tModuleSolderedToMotherboard (2), tSFPTransceiver (3), tDWDMSFPTransceiver (11), tCopperSFPTransceiver(254), vendorSpecific (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Physical type of device" ::= { convSXLSFPDescriptionEntry 10 } convSxLSFPConnector OBJECT-TYPE SYNTAX INTEGER { unspecified (0), cSC (1), cFibreChannelStyle1CopperConnector (2), cFibreChannelStyle2CopperConnector (3), cBncTnc (4), cFibreChannerCoaxialHeader (5), cFibreJack (6), cLC (7), cMTRJ (8), cMU (9), cSG (10), cOpticalPigtail(11), cHSSDCII (32), cCopperPigtail (33), cRJ45 (34), unknown(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The connector value indicates the external connector provided on the interface." ::= { convSXLSFPDescriptionEntry 11 } convSxLSFPWavelength OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The laser wavelength is the nominal transmitter output wavelength at room temperature. The value is in nanometers [nm]. This field allows the user to read the laser wavelength directly, so it is not necessary to infer it from the transceiver 'Code for Electronic Compatibility'." ::= { convSXLSFPDescriptionEntry 12 } --************************Table************************************** convSxLSFPBitrateTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLSFPBitrateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Optical transceiver bitrate table" ::= { convSxSFPIdentifikation 2 } convSxLSFPBitrateEntry OBJECT-TYPE SYNTAX ConvSxLSFPBitrateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Transceiver bitrate" INDEX { convSxLPortIndex } ::= { convSxLSFPBitrateTable 1 } ConvSxLSFPBitrateEntry ::= SEQUENCE { convSxLPortIndex INTEGER, convSxLSlot INTEGER, convSxLPort INTEGER, convSxLSFPBitrateNominal INTEGER, convSxLSFPBitrateMax INTEGER, convSxLSFPBitrateMin INTEGER } convSxLSFPBitrateNominal OBJECT-TYPE SYNTAX INTEGER { notAvailable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal bit rate is specified in units of 1 Megabit per second, rounded up to the next 100 Megabits per second. The bit rate includes those bits necessary to encode and delimit the signal as well as those bits carrying data information. A value of 0 indicates that the bit rate is not specified and must be determined from the transceiver technology. The actual information transfer rate will depend on the data encoding defined by the encoding value." ::= { convSxLSFPBitrateEntry 4 } convSxLSFPBitrateMax OBJECT-TYPE SYNTAX INTEGER { notAvailable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The upper bit rate limit at which the SFP transceiver will still meet its specifications is specified in units of 1 Megabit per second. A value of 0 indicates that this field is not specified." ::= { convSxLSFPBitrateEntry 5 } convSxLSFPBitrateMin OBJECT-TYPE SYNTAX INTEGER { notAvailable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The lower bit rate limit at which the SFP transceiver will still meet its specifications is specified in units of 1 Megabit per second. A value of 0 indicates that this field is not specified." ::= { convSxLSFPBitrateEntry 6 } --************************Table************************************** convSxLSFPLengthTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLSFPLengthEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Optical Transceiver Length Table" ::= { convSxSFPIdentifikation 3 } convSxLSFPLengthEntry OBJECT-TYPE SYNTAX ConvSxLSFPLengthEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Optical Transceiver Length Coding Entries" INDEX { convSxLPortIndex } ::= { convSxLSFPLengthTable 1 } ConvSxLSFPLengthEntry ::= SEQUENCE { convSxLPortIndex INTEGER, convSxLSlot INTEGER, convSxLPort INTEGER, convSxLSFPLength9km INTEGER, convSxLSFPLength9m INTEGER, convSxLSFPLength50 INTEGER, convSxLSFPLength62 INTEGER, convSxLSFPLengthCopper INTEGER } convSxLSFPLength9km OBJECT-TYPE SYNTAX INTEGER { grater254km(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using single mode fiber. The value is in units of kilometers. A value of 255 means that the transceiver supports a link greater than 254 km. A value of 0 means that the transceiver does not support single mode fiber or that the length information must be determined from the transceiver technology." ::= { convSxLSFPLengthEntry 4 } convSxLSFPLength9m OBJECT-TYPE SYNTAX INTEGER { greater25km(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using single mode fiber. The value is in units of 100 meters. A value of 255 means that the transceiver supports a link greater than 25.4 km. A value of 0 means that the transceiver does not support single mode fiber or that the length information must be determined from the transceiver technology." ::= { convSxLSFPLengthEntry 5 } convSxLSFPLength50 OBJECT-TYPE SYNTAX INTEGER { greater2540m(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using 50 micron multi mode fiber. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link greater than 2.54 km. A value of 0 means that the transceiver does not support 50 micron multi mode fiber or that the length information must be determined from the transceiver technology." ::= { convSxLSFPLengthEntry 6 } convSxLSFPLength62 OBJECT-TYPE SYNTAX INTEGER { greater2540m(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using 62.5 micron multi mode fiber. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link greater than 2.54 km. A value of 0 means that the transceiver does not support 62.5 micron multi mode fiber or that the length information must be determined from the transceiver technology." ::= { convSxLSFPLengthEntry 7 } convSxLSFPLengthCopper OBJECT-TYPE SYNTAX INTEGER { greater254m(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using copper cable. The value is in units of 1 meter. A value of 255 means that the transceiver supports a link greater than 254 m. A value of 0 means that the transceiver does not support copper cable or that the length information must be determined from the transceiver technology. Further information about the cable design, equalization, and connectors is usually required to guarantee meeting of particular length information." ::= { convSxLSFPLengthEntry 8 } --************************Table************************************** convSxLSFPCompCodes OBJECT IDENTIFIER ::= { convSxSFPIdentifikation 4 } --************************Table************************************** convSxLSFPCompCodeSonetTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLSFPCompCodeSonetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Optical transceiver sonet compatibility table" ::= { convSxLSFPCompCodes 1 } convSxLSFPCompCodeSonetEntry OBJECT-TYPE SYNTAX ConvSxLSFPCompCodeSonetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Transceiver compatibility code entries" INDEX { convSxLPortIndex } ::= { convSxLSFPCompCodeSonetTable 1 } ConvSxLSFPCompCodeSonetEntry ::= SEQUENCE { convSxLPortIndex INTEGER, convSxLSlot INTEGER, convSxLPort INTEGER, convSxLSFPCSProtocol INTEGER, convSxLSFPCSRange INTEGER, convSxLSFPCSFiberType INTEGER } convSxLSFPCSProtocol OBJECT-TYPE SYNTAX INTEGER { notSupported (0), sOC3 (1), sOC12 (2), sOC48 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Supported protocol" ::= { convSxLSFPCompCodeSonetEntry 4 } convSxLSFPCSRange OBJECT-TYPE SYNTAX INTEGER { notSupported (0), short (1), intermediate (2), long (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Optical transceivers range" ::= { convSxLSFPCompCodeSonetEntry 5 } convSxLSFPCSFiberType OBJECT-TYPE SYNTAX INTEGER { notSupported (0), multimode (1), singlemode (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Supported fiber type" ::= { convSxLSFPCompCodeSonetEntry 6 } --************************Table************************************** convSxLSFPCompCodeGigabitEthernetTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLSFPCompCodeGigabitEthernetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Optical transceiver gigabit Ethernet compatibility table" ::= { convSxLSFPCompCodes 2 } convSxLSFPCompCodeGigabitEthernetEntry OBJECT-TYPE SYNTAX ConvSxLSFPCompCodeGigabitEthernetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entries" INDEX { convSxLPortIndex } ::= { convSxLSFPCompCodeGigabitEthernetTable 1 } ConvSxLSFPCompCodeGigabitEthernetEntry ::= SEQUENCE { convSxLPortIndex INTEGER, convSxLSlot INTEGER, convSxLPort INTEGER, convSxLSFPCGType INTEGER } convSxLSFPCGType OBJECT-TYPE SYNTAX INTEGER { notSupported (0), g1000BASE-SX (1), g1000BASE-LX (2), g1000BASE-CX (4), g1000BASE-T (8), g100Base-Fx (32), g100Base-Fx-LX (48) } MAX-ACCESS read-only STATUS current DESCRIPTION "Supported protocol" ::= { convSxLSFPCompCodeGigabitEthernetEntry 4 } --************************Table************************************** convSxLSFPCompCodeFibreChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLSFPCompCodeFibreChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Optical transceiver fibre channel compatibility table" ::= { convSxLSFPCompCodes 3 } convSxLSFPCompCodeFibreChannelEntry OBJECT-TYPE SYNTAX ConvSxLSFPCompCodeFibreChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entries" INDEX { convSxLPortIndex } ::= { convSxLSFPCompCodeFibreChannelTable 1 } ConvSxLSFPCompCodeFibreChannelEntry ::= SEQUENCE { convSxLPortIndex INTEGER, convSxLSlot INTEGER, convSxLPort INTEGER, convSxLSFPCFcMedia INTEGER, convSxLSFPCFcTech INTEGER, convSxLSFPCFcLinkLength INTEGER, convSxLSFPCFcSpeed INTEGER } convSxLSFPCFcMedia OBJECT-TYPE SYNTAX INTEGER { mnotSupported (0), mSingleMode (1), reserved (2), mMultiMode50 (4), mMultiMode62-5 (8), mMultiMode50m-62-5m(12), mVideoCoax (16), mMiniatureCoax (32), mShieldedTwistedPair (64), mTwinAxialPair (128) } MAX-ACCESS read-only STATUS current DESCRIPTION "Supported media types" ::= { convSxLSFPCompCodeFibreChannelEntry 4 } convSxLSFPCFcTech OBJECT-TYPE SYNTAX INTEGER { notSupported (0), tLongwaveLaserLL (10), tLongwaveLaserLC (11), tShortwaveLaserW-OFC (12), tShortwaveLaserW-O-OFC (13), tElectricalInterenclosure (20), tElectricalIntraenclosure (21) } MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitter technology" ::= { convSxLSFPCompCodeFibreChannelEntry 5 } convSxLSFPCFcLinkLength OBJECT-TYPE SYNTAX INTEGER { notSupported (0), longDistance (16), intermediateDistance (32), shortDistance (64), verylongDistance (128) } MAX-ACCESS read-only STATUS current DESCRIPTION "Link length supported by transceiver" ::= { convSxLSFPCompCodeFibreChannelEntry 6 } convSxLSFPCFcSpeed OBJECT-TYPE SYNTAX INTEGER { notSupported(0), fcSpeed100MByte(1), fcSpeed200MByte(4), fcSpeed100-200MByte(5), fcSpeed400MByte(16), fcSpeed100-200-400MByte(21) } MAX-ACCESS read-only STATUS current DESCRIPTION "Fibre channel speed" ::= { convSxLSFPCompCodeFibreChannelEntry 7 } --************************Table************************************** convSxLCopperSFPTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLCopperSFPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Overview and configuration of copper SFP table" ::= { convSxSFPIdentifikation 5 } convSxLCopperSFPEntry OBJECT-TYPE SYNTAX ConvSxLCopperSFPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Transceiver overview and configuration entries" INDEX { convSxLPortIndex } ::= { convSxLCopperSFPTable 1 } ConvSxLCopperSFPEntry ::= SEQUENCE { convSxLPortIndex INTEGER, convSxLSlot INTEGER, convSxLPort INTEGER, convSxLConfigSpeed INTEGER, convSxLConfigDuplex INTEGER, convSxLCuPhyId INTEGER, convSxLCuSFPLink INTEGER, convSxLCuSFPSpeed INTEGER, convSxLCuSFPDuplex INTEGER, convSxLCuSFPAutoMDIx INTEGER, convSxLCuSFPConfigMode INTEGER } convSxLConfigSpeed OBJECT-TYPE SYNTAX INTEGER { s10Mbit (1), s100Mbit (2), s1000Mbit (3), notSupported (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "User defined configuration of speed" ::= { convSxLCopperSFPEntry 3 } convSxLConfigDuplex OBJECT-TYPE SYNTAX INTEGER { halfduplex (1), fullduplex (2), notSupported (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "User defined configuration of duplex mode" ::= { convSxLCopperSFPEntry 4 } convSxLCuPhyId OBJECT-TYPE SYNTAX INTEGER { unknown (0), marvellPhy (1), notSupported (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Physical transceiver installed in SFP, if unkown the transceiver is not supported" ::= { convSxLCopperSFPEntry 5 } convSxLCuSFPLink OBJECT-TYPE SYNTAX INTEGER { down (0), up (1), notSupported (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Link status of internal physical in copper SFP" ::= { convSxLCopperSFPEntry 6 } convSxLCuSFPSpeed OBJECT-TYPE SYNTAX INTEGER { down (0), s10Mbit (1), s100Mbit (2), s1000Mbit (3), notSupported (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "actual speed status of internal physical in copper SFP" ::= { convSxLCopperSFPEntry 7 } convSxLCuSFPDuplex OBJECT-TYPE SYNTAX INTEGER { down (0), halfduplex (1), fullduplex (2), notSupported (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "actual duplex mode status of internal physical in copper SFP" ::= { convSxLCopperSFPEntry 8 } convSxLCuSFPAutoMDIx OBJECT-TYPE SYNTAX INTEGER { on (0), off (1), notSupported (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "actual of status MDI-connection in copper SFP" ::= { convSxLCopperSFPEntry 9 } convSxLCuSFPConfigMode OBJECT-TYPE SYNTAX INTEGER { unknown (0), auto (1), forced (2), notSupported (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "actual config mode in copper SFP" ::= { convSxLCopperSFPEntry 10 } --************************Table************************************** convSxLDWDMSFPTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLDWDMSFPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Overview and configuration of DWDM SFP table" ::= { convSxSFPIdentifikation 6 } convSxLDWDMSFPEntry OBJECT-TYPE SYNTAX ConvSxLDWDMSFPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Transceiver overview and configuration entries" INDEX { convSxLPortIndex } ::= { convSxLDWDMSFPTable 1 } ConvSxLDWDMSFPEntry ::= SEQUENCE { convSxLPortIndex INTEGER, convSxLSlot INTEGER, convSxLPort INTEGER, convSxLDWDMPowerClass INTEGER, convSxLDWDMMaxSupplyCurrent INTEGER, convSxLChannelSpacing INTEGER, convSxLNumberofChannels INTEGER } convSxLDWDMPowerClass OBJECT-TYPE SYNTAX INTEGER { p-upto1W (0), p-between1Wand1-5W (1), p-morethan1-5W (2), notSupported (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Power class of installed DWDM-SFP " ::= { convSxLDWDMSFPEntry 4 } convSxLDWDMMaxSupplyCurrent OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Defines the maximum supply current the module will consume under worst conditions in units of 4mA" ::= { convSxLDWDMSFPEntry 5 } convSxLChannelSpacing OBJECT-TYPE SYNTAX INTEGER { g200GHz (0), g100GHz (1), g50GHz (2), notSupported (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the densest channel spacing the module is compatible with" ::= { convSxLDWDMSFPEntry 6 } convSxLNumberofChannels OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the number of channels over which the module may be tuned by user command. If not tunable the number is 1" ::= { convSxLDWDMSFPEntry 7 } --************************Table************************************** convSxLSFPDMIParamTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLSFPDMIParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Optical transceiver measurement parameter table" ::= { convSPEEDDUALLINE 8 } convSxLSFPDMIParamEntry OBJECT-TYPE SYNTAX ConvSxLSFPDMIParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entries" INDEX { convSxLPortIndex } ::= { convSxLSFPDMIParamTable 1 } ConvSxLSFPDMIParamEntry ::= SEQUENCE { convSxLPortIndex INTEGER, convSxLSlot INTEGER, convSxLPort INTEGER, convSxLSFPDMIRxLevel INTEGER, convSxLSFPDMIRxHighAlarm INTEGER, convSxLSFPDMITxLevel INTEGER, convSxLSFPDMITxBias INTEGER, convSxLSFPDMIVcc INTEGER, convSxLSFPDMITemp INTEGER } convSxLSFPDMIRxLevel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Optical receive power " ::= { convSxLSFPDMIParamEntry 4 } convSxLSFPDMIRxHighAlarm OBJECT-TYPE SYNTAX INTEGER { normal (0), active (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of receive optical power, active when overloaded" ::= { convSxLSFPDMIParamEntry 5 } convSxLSFPDMITxLevel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Optical transmit power " ::= { convSxLSFPDMIParamEntry 6 } convSxLSFPDMITxBias OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Transceiver hardware parameter: laser bias current" ::= { convSxLSFPDMIParamEntry 7 } convSxLSFPDMIVcc OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Transceiver hardware parameter: supply voltage" ::= { convSxLSFPDMIParamEntry 8 } convSxLSFPDMITemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Transceiver hardware parameter: temperature value" ::= { convSxLSFPDMIParamEntry 9 } --************************Table************************************** convSxLSFPDMIThresholdTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLSFPDMIThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Optical transceiver measurement threshold table" ::= { convSPEEDDUALLINE 9 } convSxLSFPDMIThresholdEntry OBJECT-TYPE SYNTAX ConvSxLSFPDMIThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Measurement parameter overview" INDEX { convSxLPortIndex } ::= { convSxLSFPDMIThresholdTable 1 } ConvSxLSFPDMIThresholdEntry ::= SEQUENCE { convSxLPortIndex INTEGER, convSxLSlot INTEGER, convSxLPort INTEGER, convSxLSFPDMIRxLowThresholdWarningLevel INTEGER, convSxLSFPDMIRxLowThresholdAlarmLevel INTEGER, convSxLSFPDMITxLowThresholdWarningLevel INTEGER, convSxLSFPDMITxLowThresholdAlarmLevel INTEGER, convSxLSFPDMIThresholdsUsage INTEGER } convSxLSFPDMIRxLowThresholdWarningLevel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Optical receive power warning level. Value display and set is dBm/100" ::= { convSxLSFPDMIThresholdEntry 4 } convSxLSFPDMIRxLowThresholdAlarmLevel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Optical receive power alarm level. Value display is dBm/100" ::= { convSxLSFPDMIThresholdEntry 5 } convSxLSFPDMITxLowThresholdWarningLevel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Optical transmit power warning level. Value display and set is dBm/100" ::= { convSxLSFPDMIThresholdEntry 6 } convSxLSFPDMITxLowThresholdAlarmLevel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Optical transmit power alarm level. Value display is dBm/100" ::= { convSxLSFPDMIThresholdEntry 7 } convSxLSFPDMIThresholdsUsage OBJECT-TYPE SYNTAX INTEGER { userDefinedThresholds (0), sFPVendorThresholds(1), notAvailable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set threshold usage. Activate user defined or vendor defined thresholds" ::= { convSxLSFPDMIThresholdEntry 8 } --************************Table************************************** convSxLPortEventTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLPortEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port event Table" ::= { convSPEEDDUALLINE 10 } convSxLPortEventEntry OBJECT-TYPE SYNTAX ConvSxLPortEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port event table entries" INDEX { convSxLPortIndex } ::= { convSxLPortEventTable 1 } ConvSxLPortEventEntry ::= SEQUENCE { convSxLPortIndex INTEGER, convSxLSlot INTEGER, convSxLPort INTEGER, convSxLSFPDMIRxLowWarningEvent INTEGER, convSxLSFPDMIRxLowAlarmEvent INTEGER, convSxLSFPDMITxLowWarningEvent INTEGER, convSxLSFPDMITxLowAlarmEvent INTEGER, convSxLSFPDMIBiasAlarmEvent INTEGER, convSxLSFPDMIRxHighAlarmEvent INTEGER, convSxLSFPDWDMLaserTHighAlarmEvent INTEGER, convSxLSFPDWDMLaserTLowAlarmEvent INTEGER, convSxLSFPDWDMTECHighAlarmEvent INTEGER, convSxLSFPDWDMTECLowAlarmEvent INTEGER, convSxLSFPDMITempHighWarningEvent INTEGER, convSxLSFPDMITempHighAlarmEvent INTEGER } convSxLSFPDMIRxLowWarningEvent OBJECT-TYPE SYNTAX INTEGER { normal (0), active (1), notimplemented (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Receive power - low warning" ::= { convSxLPortEventEntry 4 } convSxLSFPDMIRxLowAlarmEvent OBJECT-TYPE SYNTAX INTEGER { normal (0), active (1), notimplemented (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Receive power - low alarm" ::= { convSxLPortEventEntry 5 } convSxLSFPDMITxLowWarningEvent OBJECT-TYPE SYNTAX INTEGER { normal (0), active (1), notimplemented (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Output power - low warning" ::= { convSxLPortEventEntry 6 } convSxLSFPDMITxLowAlarmEvent OBJECT-TYPE SYNTAX INTEGER { normal (0), active (1), notimplemented (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Output power - low alarm" ::= { convSxLPortEventEntry 7 } convSxLSFPDMIBiasAlarmEvent OBJECT-TYPE SYNTAX INTEGER { normal (0), active (1), notimplemented (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitter bias current is low" ::= { convSxLPortEventEntry 8 } convSxLSFPDMIRxHighAlarmEvent OBJECT-TYPE SYNTAX INTEGER { normal (0), active (1), notimplemented (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Receiver input power is high" ::= { convSxLPortEventEntry 9 } convSxLSFPDWDMLaserTHighAlarmEvent OBJECT-TYPE SYNTAX INTEGER { normal (0), active (1), notimplemented (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set when laser temperature or wavelength exceeds high alarm level." ::= { convSxLPortEventEntry 10 } convSxLSFPDWDMLaserTLowAlarmEvent OBJECT-TYPE SYNTAX INTEGER { normal (0), active (1), notimplemented (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set when laser temperature or wavelength exceeds low alarm level." ::= { convSxLPortEventEntry 11 } convSxLSFPDWDMTECHighAlarmEvent OBJECT-TYPE SYNTAX INTEGER { normal (0), active (1), notimplemented (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set when TEC current exceeds high alarm level (cooling problem)" ::= { convSxLPortEventEntry 12 } convSxLSFPDWDMTECLowAlarmEvent OBJECT-TYPE SYNTAX INTEGER { normal (0), active (1), notimplemented (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set when TEC current exceeds low alarm level (heating problem)" ::= { convSxLPortEventEntry 13 } convSxLSFPDMITempHighWarningEvent OBJECT-TYPE SYNTAX INTEGER { normal (0), active (1), notimplemented (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Transceiver DMI temperature high warning event" ::= { convSxLPortEventEntry 14 } convSxLSFPDMITempHighAlarmEvent OBJECT-TYPE SYNTAX INTEGER { normal (0), active (1), notimplemented (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Transceiver DMI temperature high alarm event" ::= { convSxLPortEventEntry 15 } --************************Table************************************** convSxLInventoryTable OBJECT-TYPE SYNTAX SEQUENCE OF ConvSxLInventoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of all serial numbers installed in module" ::= { convSPEEDDUALLINE 11 } convSxLInventoryEntry OBJECT-TYPE SYNTAX ConvSxLInventoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entries" INDEX { convSxLMSlot } ::= { convSxLInventoryTable 1 } ConvSxLInventoryEntry ::= SEQUENCE { convSxLMSlot INTEGER, convSxLModuleSerialNumber DisplayString, convSxLSFPPort1SerialNumber DisplayString, convSxLSFPPort2SerialNumber DisplayString, convSxLSFPPort3SerialNumber DisplayString, convSxLSFPPort4SerialNumber DisplayString } convSxLModuleSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number of module " ::= { convSxLInventoryEntry 3 } convSxLSFPPort1SerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number of installed transceiver" ::= { convSxLInventoryEntry 4 } convSxLSFPPort2SerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number of installed transceiver" ::= { convSxLInventoryEntry 5 } convSxLSFPPort3SerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number of installed transceiver" ::= { convSxLInventoryEntry 6 } convSxLSFPPort4SerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number of installed transceiver" ::= { convSxLInventoryEntry 7 } --***************************************************************** --************* Trap's **************************************** coldStart TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot} DESCRIPTION "ColdStart" ::= 40 reboot TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot} DESCRIPTION "Reboot" ::= 41 fanError TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot} DESCRIPTION "FANError" ::= 42 fanOK TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot} DESCRIPTION "FANOK" ::= 43 powerFailure TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot } DESCRIPTION "PowerFailure" ::= 44 powerOK TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot } DESCRIPTION "PowerOK" ::= 45 highTemp TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "HighTemp" ::= 46 tempOK TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "TempOK" ::= 47 transceiverRemoved TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "SFPRemoved" ::= 48 transceiverInserted TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "SFPInserted" ::= 49 moduleInserted TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot} DESCRIPTION "ModuleInserted" ::= 50 moduleRemoved TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot} DESCRIPTION "ModuleRemoved" ::= 51 portTxUp TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "PortTxUp" ::= 52 portTxDown TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "PortTxDown" ::= 53 portUp TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "PortUp" ::= 54 portDown TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "PortDown" ::= 55 txFault TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "TxFault" ::= 56 badPasswd TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot } DESCRIPTION "BadPasswd" ::= 57 softwareUpdateReady TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot } DESCRIPTION "SoftwareUpdateReady" ::= 58 hardwareTrap TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot } DESCRIPTION "HardwareTrap" ::= 59 cdrAlarm TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot } DESCRIPTION "CDRAlarm" ::= 60 protectionMain TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "ProtectionMain" ::= 61 protectionBackup TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "ProtectionBackup" ::= 62 optRxLevelWarning TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "OptRxLevelWarning" ::= 63 optRxLevelAlarm TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "OptRxLevelAlarm" ::= 64 optRxLevelOK TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "OptRxLevelOK" ::= 65 optTxLevelWarning TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "OptTxLevelWarning" ::= 66 optTxLevelAlarm TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "OptTxLevelAlarm" ::= 67 optTxLevelOK TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "OptTxLevelOK" ::= 68 optTxBiasAlarm TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "TX Bias Alarm" ::= 69 optTxBiasOK TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "TX Bias OK" ::= 70 optRxPowerOverload TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "High optical input power Alarm" ::= 71 configError TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "Configuration error. An set command or config file transfer was not successful." ::= 72 configuration TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "Configuration file information" ::= 73 maintenance TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "Maintennance Change" ::= 74 ampFail TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "AMP error is occured" ::= 75 ampOk TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "AMP error is cleared" ::= 76 dwdmAlarm TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "DWDM transceiver alarm occured" ::= 77 dwdmOk TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "DWDM transceiver alarm cleared" ::= 78 firmwareError TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "firmware or kernel transfer or flashing error" ::= 79 unspecified TRAP-TYPE ENTERPRISE PanDacom VARIABLES { Descr, Slot, Port } DESCRIPTION "Unspecified" ::= 255 END