-- ===================================================================== -- == OG-OMSTATUS-MIB: == -- == Opengear Operation Manager Status Management Information Base == -- == == -- == (c) Copyright 2020 Opengear Inc. == -- ===================================================================== OG-OMTELEM-MIB DEFINITIONS ::= BEGIN IMPORTS ogMgmt FROM OG-SMI-MIB MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF Counter32, Counter64, Integer32, MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI DateAndTime, DisplayString FROM SNMPv2-TC; ogOmTelem MODULE-IDENTITY LAST-UPDATED "202311130934Z" ORGANIZATION "Opengear Inc." CONTACT-INFO "Opengear Inc. 630 West 9560 South, Suite A, Sandy, UT 84070 support@opengear.com" DESCRIPTION "Opengear Operation Manager Telemetry MIB" REVISION "202311130934Z" DESCRIPTION "Update Opengear Telemetry MIB for version 23.12.0. - Add lteNr5g and nr5g enum values to accessTechnology leaf." REVISION "202103121454Z" DESCRIPTION "added lastActiveTime to cell-uim submodule" REVISION "202008041454Z" DESCRIPTION "Initial revision" ::= { ogMgmt 19 } ogOmSystem OBJECT IDENTIFIER ::= { ogOmTelem 1 } ogOmSystemHostName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The current host name (if applicable)." ::= { ogOmSystem 1 } ogOmSystemSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The current serial number (if applicable)." ::= { ogOmSystem 2 } ogOmSystemFirmwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The current device firmware." ::= { ogOmSystem 3 } ogOmSystemVendor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The device vendor." ::= { ogOmSystem 4 } ogOmSystemModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The device model." ::= { ogOmSystem 5 } ogOmSerialPort OBJECT IDENTIFIER ::= { ogOmTelem 2 } ogOmSerialPortCount OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of serial ports" ::= { ogOmSerialPort 1 } ogOmSerialPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SerialPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Operations Manager Serial Port table structure." ::= { ogOmSerialPort 2 } ogOmSerialPortEntry OBJECT-TYPE SYNTAX SerialPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A serial port status table entry." INDEX { ogOmSerialPortIndex } ::= { ogOmSerialPortTable 1 } SerialPortEntry ::= SEQUENCE { ogOmSerialPortIndex Integer32, ogOmSerialPortLabel DisplayString, ogOmSerialPortSpeed Integer32, ogOmSerialPortDataBits Integer32, ogOmSerialPortParity INTEGER, ogOmSerialPortStopBits INTEGER, ogOmSerialPortFlowControl INTEGER, ogOmSerialPortMode INTEGER, ogOmSerialPortPinout INTEGER, ogOmSerialPortLogLevel INTEGER, ogOmSerialPortRxBytes Counter64, ogOmSerialPortTxBytes Counter64, ogOmSerialPortFramingErrors Counter64, ogOmSerialPortParityErrors Counter64, ogOmSerialPortOverrunErrors Counter64, ogOmSerialPortBreaks Counter64, ogOmSerialPortDCD INTEGER, ogOmSerialPortDTR INTEGER, ogOmSerialPortDSR INTEGER, ogOmSerialPortCTS INTEGER, ogOmSerialPortRTS INTEGER } ogOmSerialPortIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the serial port table of this status" ::= { ogOmSerialPortEntry 1 } ogOmSerialPortLabel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port descriptive name" ::= { ogOmSerialPortEntry 2 } ogOmSerialPortSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port speed in bits per second" ::= { ogOmSerialPortEntry 3 } ogOmSerialPortDataBits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port character size" ::= { ogOmSerialPortEntry 4 } ogOmSerialPortParity OBJECT-TYPE SYNTAX INTEGER { none(1), odd(2), even(3), mark(4), space(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port parity" ::= { ogOmSerialPortEntry 5 } ogOmSerialPortStopBits OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), oneAndAHalf(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port number of stop bits" ::= { ogOmSerialPortEntry 6 } ogOmSerialPortFlowControl OBJECT-TYPE SYNTAX INTEGER { none(1), hardware(2), software(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port flow control type" ::= { ogOmSerialPortEntry 7 } ogOmSerialPortMode OBJECT-TYPE SYNTAX INTEGER { disabled(1), localConsole(2), consoleServer(3), bridge(4), terminalServer(5), reserved(6), pduDevice(7), unknown(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port operational mode type" ::= { ogOmSerialPortEntry 8 } ogOmSerialPortPinout OBJECT-TYPE SYNTAX INTEGER { x1(1), x2(2), usb(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port pinout type" ::= { ogOmSerialPortEntry 9 } ogOmSerialPortLogLevel OBJECT-TYPE SYNTAX INTEGER { disabled(1), connect(2), inputAndOutput(3), inputOnly(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port logging level" ::= { ogOmSerialPortEntry 10 } ogOmSerialPortRxBytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port bytes received" ::= { ogOmSerialPortEntry 11 } ogOmSerialPortTxBytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port bytes transmitted" ::= { ogOmSerialPortEntry 12 } ogOmSerialPortFramingErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port framing error total." ::= { ogOmSerialPortEntry 13 } ogOmSerialPortParityErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port parity error total." ::= { ogOmSerialPortEntry 14 } ogOmSerialPortOverrunErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port Overrun Error total." ::= { ogOmSerialPortEntry 15 } ogOmSerialPortBreaks OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port break total" ::= { ogOmSerialPortEntry 16 } ogOmSerialPortDCD OBJECT-TYPE SYNTAX INTEGER { unknown(0), on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the DCD signal." ::= { ogOmSerialPortEntry 17 } ogOmSerialPortDTR OBJECT-TYPE SYNTAX INTEGER { unknown(0), on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the DTR signal." ::= { ogOmSerialPortEntry 18 } ogOmSerialPortDSR OBJECT-TYPE SYNTAX INTEGER { unknown(0), on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the DSR signal." ::= { ogOmSerialPortEntry 19 } ogOmSerialPortCTS OBJECT-TYPE SYNTAX INTEGER { unknown(0), on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the CTS signal." ::= { ogOmSerialPortEntry 20 } ogOmSerialPortRTS OBJECT-TYPE SYNTAX INTEGER { unknown(0), on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the RTS signal." ::= { ogOmSerialPortEntry 21 } ogOmSerialUser OBJECT IDENTIFIER ::= { ogOmTelem 3 } ogOmSerialUserTable OBJECT-TYPE SYNTAX SEQUENCE OF SerialUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Operations Manager Serial Console User table entry structure." ::= { ogOmSerialUser 1 } ogOmSerialUserEntry OBJECT-TYPE SYNTAX SerialUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A user logged in on the serial port" INDEX { ogOmSerialUserIndex } ::= { ogOmSerialUserTable 1 } SerialUserEntry ::= SEQUENCE { ogOmSerialUserIndex Integer32, ogOmSerialUserStartTime DateAndTime, ogOmSerialUserPortNumber Integer32, ogOmSerialUserPortLabel DisplayString, ogOmSerialUserName DisplayString } ogOmSerialUserIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the serial port active users table" ::= { ogOmSerialUserEntry 1 } ogOmSerialUserStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The time and date the user session started." ::= { ogOmSerialUserEntry 2 } ogOmSerialUserPortNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port number" ::= { ogOmSerialUserEntry 3 } ogOmSerialUserPortLabel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The readable label for the serial port." ::= { ogOmSerialUserEntry 4 } ogOmSerialUserName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the user logged in on the port." ::= { ogOmSerialUserEntry 5 } ogOmWebUser OBJECT IDENTIFIER ::= { ogOmTelem 4 } ogOmWebUserTable OBJECT-TYPE SYNTAX SEQUENCE OF WebUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Operations Manager Web UI User table structure." ::= { ogOmWebUser 1 } ogOmWebUserEntry OBJECT-TYPE SYNTAX WebUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A user logged in to the Web Interface" INDEX { ogOmWebUserIndex } ::= { ogOmWebUserTable 1 } WebUserEntry ::= SEQUENCE { ogOmWebUserIndex Integer32, ogOmWebUserStartTime DateAndTime, ogOmWebUserName DisplayString, ogOmWebUserSourceAddress DisplayString, ogOmWebUserSourcePort Integer32 } ogOmWebUserIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the Web Interface users table" ::= { ogOmWebUserEntry 1 } ogOmWebUserStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The web users session start date and time." ::= { ogOmWebUserEntry 2 } ogOmWebUserName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The web users active username." ::= { ogOmWebUserEntry 3 } ogOmWebUserSourceAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The web users source address." ::= { ogOmWebUserEntry 4 } ogOmWebUserSourcePort OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The web users source tcp port." ::= { ogOmWebUserEntry 5 } ogOmCellular OBJECT IDENTIFIER ::= { ogOmTelem 5 } ogOmCellularTable OBJECT-TYPE SYNTAX SEQUENCE OF CellularEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Operations Manager Cellular modem table structure." ::= { ogOmCellular 1 } ogOmCellularEntry OBJECT-TYPE SYNTAX CellularEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A cellular modem status entry." INDEX { ogOmCellularIndex } ::= { ogOmCellularTable 1 } CellularEntry ::= SEQUENCE { ogOmCellularIndex Integer32, ogOmCellularVendor DisplayString, ogOmCellularModel DisplayString, ogOmCellularEquipmentId DisplayString, ogOmCellularFirmware DisplayString, ogOmCellularState INTEGER, ogOmCellularAccessTechnology INTEGER, ogOmCellularActiveUim Counter32, ogOmCellularUimFailoverState INTEGER } ogOmCellularIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the cellular modem status entry." ::= { ogOmCellularEntry 1 } ogOmCellularVendor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Manufacturer ID of Cellular Modem." ::= { ogOmCellularEntry 2 } ogOmCellularModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Cellular Modem model name." ::= { ogOmCellularEntry 3 } ogOmCellularEquipmentId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Cellular Modem Equipment Identifier (IMEI)." ::= { ogOmCellularEntry 4 } ogOmCellularFirmware OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The current Cellular Modem firmware revision." ::= { ogOmCellularEntry 5 } ogOmCellularState OBJECT-TYPE SYNTAX INTEGER { failed(1), unknown(2), initializing(3), locked(4), disabled(5), disabling(6), enabling(7), enabled(8), searching(9), registered(10), disconnecting(11), connecting(12), connected(13) } MAX-ACCESS read-only STATUS current DESCRIPTION "The overall current state of the modem." ::= { ogOmCellularEntry 6 } ogOmCellularAccessTechnology OBJECT-TYPE SYNTAX INTEGER { unavailable(1), cdma(2), evdo(3), gsm(4), umts(5), lte(6), gsmUmts(7), gsmUmtsLte(8), cdmaEvdo(9), cdmaEvdoLte(10), lteNr5g(11), nr5g(12) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current Radio Access Technology being used" ::= { ogOmCellularEntry 7 } ogOmCellularActiveUim OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The physical UIM card slot number that is currently active." ::= { ogOmCellularEntry 8 } ogOmCellularUimFailoverState OBJECT-TYPE SYNTAX INTEGER { unavailable(1), disabled(2), enabled(3), failingOver(4), failedOver(5), failingBack(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current UIM failover state" ::= { ogOmCellularEntry 9 } ogOmCellUim OBJECT IDENTIFIER ::= { ogOmTelem 6 } ogOmCellUimTable OBJECT-TYPE SYNTAX SEQUENCE OF CellUimEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Operations Manager Cellular modem UIM table structure." ::= { ogOmCellUim 1 } ogOmCellUimEntry OBJECT-TYPE SYNTAX CellUimEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A cellular modem UIM status entry." INDEX { ogOmCellUimIndex } ::= { ogOmCellUimTable 1 } CellUimEntry ::= SEQUENCE { ogOmCellUimIndex Integer32, ogOmCellUimPhysicalSlot Counter32, ogOmCellUimSlotState INTEGER, ogOmCellUimCardState INTEGER, ogOmCellUimIccid DisplayString, ogOmCellUimImsi DisplayString, ogOmCellUimOperatorName DisplayString, ogOmCellUimApn DisplayString, ogOmCellUimSignalQuality Integer32, ogOmCellUimRssi Integer32, ogOmCellUimConnectivityHealth INTEGER, ogOmCellUimSignalHealth INTEGER, ogOmCellUimLastUpdateTime DateAndTime, ogOmCellUimLastActiveTime DateAndTime, ogOmCellUimRoamingOperatorName DisplayString } ogOmCellUimIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the cellular modem UIM card." ::= { ogOmCellUimEntry 1 } ogOmCellUimPhysicalSlot OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The physical UIM card slot number." ::= { ogOmCellUimEntry 2 } ogOmCellUimSlotState OBJECT-TYPE SYNTAX INTEGER { unavailable(1), inactive(2), active(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the Cellular Modem signal quality." ::= { ogOmCellUimEntry 3 } ogOmCellUimCardState OBJECT-TYPE SYNTAX INTEGER { unavailable(1), absent(2), present(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current UIM Card presence state." ::= { ogOmCellUimEntry 4 } ogOmCellUimIccid OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The ICCID of the UIM card currently in use by this modem." ::= { ogOmCellUimEntry 5 } ogOmCellUimImsi OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The IMSI of the UIM card currently in use by this modem." ::= { ogOmCellUimEntry 6 } ogOmCellUimOperatorName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the home network operator for this UIM card." ::= { ogOmCellUimEntry 7 } ogOmCellUimApn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The APN configured for this cellular modem UIM card." ::= { ogOmCellUimEntry 8 } ogOmCellUimSignalQuality OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Signal quality as a percent of the dominant access technology the device is using to communicate with the network." ::= { ogOmCellUimEntry 9 } ogOmCellUimRssi OBJECT-TYPE SYNTAX Integer32 (-99..99) MAX-ACCESS read-only STATUS current DESCRIPTION "The Received Signal Strength Indicator (RSSI) for the current Radio Access Technology if applicable." ::= { ogOmCellUimEntry 10 } ogOmCellUimConnectivityHealth OBJECT-TYPE SYNTAX INTEGER { unavailable(1), bad(2), good(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the Cellular Modem connectivity testing." ::= { ogOmCellUimEntry 11 } ogOmCellUimSignalHealth OBJECT-TYPE SYNTAX INTEGER { unavailable(1), bad(2), moderate(3), good(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the Cellular Modem signal quality." ::= { ogOmCellUimEntry 12 } ogOmCellUimLastUpdateTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time of the last UIM card status check." ::= { ogOmCellUimEntry 13 } ogOmCellUimLastActiveTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time of the last UIM card activation." ::= { ogOmCellUimEntry 14 } ogOmCellUimRoamingOperatorName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the roaming network operator for this UIM card." ::= { ogOmCellUimEntry 15 } ogOmEnrollment OBJECT IDENTIFIER ::= { ogOmTelem 7 } ogOmEnrollmentTable OBJECT-TYPE SYNTAX SEQUENCE OF EnrollmentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Operations Manager Lighthouse Enrollment table structure." ::= { ogOmEnrollment 1 } ogOmEnrollmentEntry OBJECT-TYPE SYNTAX EnrollmentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Lighthouse Enrollment status entry." INDEX { ogOmEnrollmentIndex } ::= { ogOmEnrollmentTable 1 } EnrollmentEntry ::= SEQUENCE { ogOmEnrollmentIndex Integer32, ogOmEnrollmentAddress DisplayString, ogOmEnrollmentPort Integer32, ogOmEnrollmentBundle DisplayString, ogOmEnrollmentStatus INTEGER } ogOmEnrollmentIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the Lighthouse Enrollment status entry." ::= { ogOmEnrollmentEntry 1 } ogOmEnrollmentAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Lighthouse Enrollment address." ::= { ogOmEnrollmentEntry 2 } ogOmEnrollmentPort OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The Lighthouse Enrollment TCP port." ::= { ogOmEnrollmentEntry 3 } ogOmEnrollmentBundle OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Lighthouse Enrollment bundle." ::= { ogOmEnrollmentEntry 4 } ogOmEnrollmentStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), enrolling(2), connected(3), disconnected(4), registered(5), failed(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current Lighthouse Enrollment status." ::= { ogOmEnrollmentEntry 5 } ogOmPowerSupply OBJECT IDENTIFIER ::= { ogOmTelem 8 } ogOmPowerSupplyTable OBJECT-TYPE SYNTAX SEQUENCE OF PowerSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Operations Manager Power Supply table structure." ::= { ogOmPowerSupply 1 } ogOmPowerSupplyEntry OBJECT-TYPE SYNTAX PowerSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Power Supply status entry." INDEX { ogOmPowerSupplyIndex } ::= { ogOmPowerSupplyTable 1 } PowerSupplyEntry ::= SEQUENCE { ogOmPowerSupplyIndex Integer32, ogOmPowerSupplyName DisplayString, ogOmPowerSupplyDevice DisplayString, ogOmPowerSupplyInputVoltage Integer32, ogOmPowerSupplyOutputCurrent Integer32, ogOmPowerSupplyOutputPower Integer32 } ogOmPowerSupplyIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the power supply status entry." ::= { ogOmPowerSupplyEntry 1 } ogOmPowerSupplyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Power Supply name." ::= { ogOmPowerSupplyEntry 2 } ogOmPowerSupplyDevice OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Power Supply device." ::= { ogOmPowerSupplyEntry 3 } ogOmPowerSupplyInputVoltage OBJECT-TYPE SYNTAX Integer32 UNITS "0.001 volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The Power Supply input voltage." ::= { ogOmPowerSupplyEntry 4 } ogOmPowerSupplyOutputCurrent OBJECT-TYPE SYNTAX Integer32 UNITS "0.001 Amps" MAX-ACCESS read-only STATUS current DESCRIPTION "The Power Supply output current." ::= { ogOmPowerSupplyEntry 5 } ogOmPowerSupplyOutputPower OBJECT-TYPE SYNTAX Integer32 UNITS "Watts" MAX-ACCESS read-only STATUS current DESCRIPTION "The Power Supply output power." ::= { ogOmPowerSupplyEntry 6 } ogOmTempSensor OBJECT IDENTIFIER ::= { ogOmTelem 9 } ogOmTempSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF TempSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Operations Manager Temperature Sensor table structure." ::= { ogOmTempSensor 1 } ogOmTempSensorEntry OBJECT-TYPE SYNTAX TempSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Temperature Sensor status entry." INDEX { ogOmTempSensorIndex } ::= { ogOmTempSensorTable 1 } TempSensorEntry ::= SEQUENCE { ogOmTempSensorIndex Integer32, ogOmTempSensorName DisplayString, ogOmTempSensorDevice DisplayString, ogOmTempSensorValue Integer32 } ogOmTempSensorIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the Temperature Sensor status entry." ::= { ogOmTempSensorEntry 1 } ogOmTempSensorName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Temperature Sensor name." ::= { ogOmTempSensorEntry 2 } ogOmTempSensorDevice OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Temperature Sensor device." ::= { ogOmTempSensorEntry 3 } ogOmTempSensorValue OBJECT-TYPE SYNTAX Integer32 UNITS "millidegrees Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "The Temperature Sensor value." ::= { ogOmTempSensorEntry 4 } -- Conformance Information ogOmConformance OBJECT IDENTIFIER ::= { ogOmTelem 65535 } ogOmCompliances OBJECT IDENTIFIER ::= { ogOmConformance 1 } ogOmGroups OBJECT IDENTIFIER ::= { ogOmConformance 2 } -- Compliance Statements ogOmCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for the ogOm MIB." MODULE -- this module MANDATORY-GROUPS { ogOmBasicGroup } ::= { ogOmCompliances 1 } -- Units of Conformance ogOmBasicGroup OBJECT-GROUP OBJECTS { ogOmSystemHostName, ogOmSystemSerialNumber, ogOmSystemFirmwareVersion, ogOmSystemVendor, ogOmSystemModel, ogOmSerialPortCount, ogOmSerialPortLabel, ogOmSerialPortSpeed, ogOmSerialPortDataBits, ogOmSerialPortParity, ogOmSerialPortStopBits, ogOmSerialPortFlowControl, ogOmSerialPortMode, ogOmSerialPortPinout, ogOmSerialPortLogLevel, ogOmSerialPortRxBytes, ogOmSerialPortTxBytes, ogOmSerialPortFramingErrors, ogOmSerialPortParityErrors, ogOmSerialPortOverrunErrors, ogOmSerialPortBreaks, ogOmSerialPortDCD, ogOmSerialPortDTR, ogOmSerialPortDSR, ogOmSerialPortCTS, ogOmSerialPortRTS, ogOmSerialUserStartTime, ogOmSerialUserPortNumber, ogOmSerialUserPortLabel, ogOmSerialUserName, ogOmWebUserStartTime, ogOmWebUserName, ogOmWebUserSourceAddress, ogOmWebUserSourcePort, ogOmCellularVendor, ogOmCellularModel, ogOmCellularEquipmentId, ogOmCellularFirmware, ogOmCellularState, ogOmCellularAccessTechnology, ogOmCellularActiveUim, ogOmCellularUimFailoverState, ogOmCellUimPhysicalSlot, ogOmCellUimSlotState, ogOmCellUimCardState, ogOmCellUimIccid, ogOmCellUimImsi, ogOmCellUimOperatorName, ogOmCellUimApn, ogOmCellUimSignalQuality, ogOmCellUimRssi, ogOmCellUimConnectivityHealth, ogOmCellUimSignalHealth, ogOmCellUimLastUpdateTime, ogOmCellUimLastActiveTime, ogOmCellUimRoamingOperatorName, ogOmEnrollmentAddress, ogOmEnrollmentPort, ogOmEnrollmentBundle, ogOmEnrollmentStatus, ogOmPowerSupplyName, ogOmPowerSupplyDevice, ogOmPowerSupplyInputVoltage, ogOmPowerSupplyOutputCurrent, ogOmPowerSupplyOutputPower, ogOmTempSensorName, ogOmTempSensorDevice, ogOmTempSensorValue } STATUS current DESCRIPTION "A collection of ogOm related objects." ::= { ogOmGroups 1 } END