TN-BFD-MIB DEFINITIONS ::= BEGIN -- (c) Copyright 2021 Nokia Networks. All rights reserved. -- This software is the confidential and proprietary property of -- Nokia and may only be used in accordance with the terms of the -- license agreement provided with this software. IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Unsigned32 FROM SNMPv2-SMI -- MODULE-COMPLIANCE, OBJECT-GROUP -- FROM SNMPv2-CONF DisplayString, RowStatus, TimeInterval FROM SNMPv2-TC tnSRMIBModules, tnSRObjs, tnSRNotifyPrefix FROM TROPIC-GLOBAL-REG TNamedItem FROM TN-TC-MIB tnSysSwitchId FROM TROPIC-SYSTEM-MIB ; tnBfdMIBModule MODULE-IDENTITY LAST-UPDATED "201509300000Z" ORGANIZATION "Nokia" CONTACT-INFO "Nokia SROS Support Web: http://support.nokia.com" DESCRIPTION "This document is the SNMP MIB module to manage and provision BFD templates on Nokia SROS equipment. This SNMP MIB module (Specification) embodies Nokia's proprietary intellectual property. Nokia retains all title and ownership in the Specification, including any revisions. Nokia grants all interested parties a non-exclusive license to use and distribute an unmodified copy of this Specification in connection with management of Nokia products, and without fee, provided this copyright notice and license appear on all copies. This Specification is supplied 'as is', and Nokia makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification." -- -- Revision History -- REVISION "201509300000Z" DESCRIPTION "Changed the DEFVAL for tnBfdAdminTemplateTxInt and tnBfdAdminTemplateRxInt: From 100 to 3." ::= { tnSRMIBModules 85 } -- ---------------------------------------------------------------------------- -- Nokia SROS series Delivery Appliance MIB structure -- ---------------------------------------------------------------------------- tnBfdObjects OBJECT IDENTIFIER ::= { tnSRObjs 85 } -- -- tnBfdConformance OBJECT IDENTIFIER ::= { tnSRConfs 85 } -- tnBfdCompliances OBJECT IDENTIFIER ::= { tnBfdConformance 1 } -- tnBfdGroups OBJECT IDENTIFIER ::= { tnBfdConformance 2 } -- tnBfdOperObjects OBJECT IDENTIFIER ::= { tnBfdObjects 1 } tnBfdAdminObjects OBJECT IDENTIFIER ::= { tnBfdObjects 2 } -- -- Administrative value objects -- tnBfdAdminControlObjects OBJECT IDENTIFIER ::= { tnBfdAdminObjects 1 } tnBfdAdminValueObjects OBJECT IDENTIFIER ::= { tnBfdAdminObjects 2 } -- -- Administrative value control objects -- tnBfdAdminOwner OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Who has last initialized the administrative tables, who is making all the changes, and who is expected to either commit or re-initialize (ABORT-TRANSACTION). tnBfdAdminOwner is advisory only. Before beginning a transaction, read tnBfdAdminOwner. If it is empty then proceed with the configuration. Set tnBfdAdminOwner after setting tnBfdAdminControlApply so that other users will be advised to not make changes to the Admin tables. Agent sets tnBfdAdminOwner to empty string after tnBfdAdminControlApply is set - either by user initializing or committing, or by agent timing out the uncommitted transactions (tnBfdAdminLastSetTimer)." ::= { tnBfdAdminControlObjects 1 } tnBfdAdminControlApply OBJECT-TYPE SYNTAX INTEGER { none(1), initialize(2), commit(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls the use of tnBfdAdminValueObjects tables. This object always reads none(1). When set to initialize(2), the objects in tnBfdAdminValueObjects tables are set to the current Operational values, from the corresponding tnBfdOperValueObjects tables. Any uncommitted changes are lost, so setting this value corresponds to both BEGIN-TRANSACTION and ABORT-TRANSACTION. When set to commit(3) (END-TRANSACTION), all of the objects from tnBfdAdminValueObjects tables are copied to the corresponding tnBfdOperValueObjects table objects." DEFVAL { none } ::= { tnBfdAdminControlObjects 2 } tnBfdAdminLastSetTimer OBJECT-TYPE SYNTAX TimeInterval UNITS "centiseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The time remaining until the agent re-initializes the administrative tables. If tnBfdAdminControlApply is not set to commit(3) within tnBfdAdminLastSetTimeout centiseconds, the agent will set it to initialize(2) and all uncommitted changes will be lost. This way, uncommitted changes from failed (uncompleted) change sets will eventually be removed, and another transaction can safely begin. This object is reset to tnBfdAdminLastSetTimeout after SNMP SET operation to any of the tnBfdAdminValueObjects tables." ::= { tnBfdAdminControlObjects 3 } tnBfdAdminLastSetTimeout OBJECT-TYPE SYNTAX TimeInterval UNITS "centiseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Timeout for tnBfdAdminLastSetTimer. The value zero is not allowed." DEFVAL { 180000 } -- 30 minutes ::= { tnBfdAdminControlObjects 4 } -- -- BFD template administrative value objects -- tnBfdAdminTemplateTable OBJECT-TYPE SYNTAX SEQUENCE OF TmnxBfdAdminTemplateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Administrative value table for BFD templates." ::= { tnBfdAdminValueObjects 1 } tnBfdAdminTemplateEntry OBJECT-TYPE SYNTAX TmnxBfdAdminTemplateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular BFD template. Entries are created by user. Entries are deleted by user." INDEX { tnSysSwitchId, tnBfdAdminTemplateName } ::= { tnBfdAdminTemplateTable 1 } TmnxBfdAdminTemplateEntry ::= SEQUENCE { tnBfdAdminTemplateName TNamedItem, tnBfdAdminTemplateRowStatus RowStatus, tnBfdAdminTemplateTxInt Unsigned32, tnBfdAdminTemplateRxInt Unsigned32, tnBfdAdminTemplateMultiplier Unsigned32, tnBfdAdminTemplateEchoRxInt Unsigned32, tnBfdAdminTemplateType INTEGER } tnBfdAdminTemplateName OBJECT-TYPE SYNTAX TNamedItem MAX-ACCESS not-accessible STATUS current DESCRIPTION "The name of this BFD template that uniquely identifies an entry in this table." ::= { tnBfdAdminTemplateEntry 1 } tnBfdAdminTemplateRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "RowStatus for this row. Legal values to write are: active(1), createAndGo(4), createAndWait(5), destroy(6). To Create a row, set this object to createAndGo or createAndWait. When tnBfdAdminControlApply is set to commit(3), the row will actually be created in the tnBfdOperTemplateTable. To destroy a row, set this object to destroy(6). If there are no objects that refer to the entry, when tnBfdAdminControlApply is set to commit(3) the row will actually be removed from the tnBfdOperTemplateTable. If there are objects that refer to the entry, the destroy SET request will fail with an error." ::= { tnBfdAdminTemplateEntry 2 } tnBfdAdminTemplateTxInt OBJECT-TYPE SYNTAX Unsigned32 (3 | 10..100000) UNITS "milliseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "The value of tnBfdAdminTemplateTxInt specifies the transmit timers for the BFD packets. A value of 3 denotes 3.33 ms" DEFVAL { 3 } ::= { tnBfdAdminTemplateEntry 3 } tnBfdAdminTemplateRxInt OBJECT-TYPE SYNTAX Unsigned32 (3 | 10..100000) UNITS "milliseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "The value of tnBfdAdminTemplateRxInt specifies the receive timers for the BFD packets. A value of 3 denotes 3.33 ms" DEFVAL { 3 } ::= { tnBfdAdminTemplateEntry 4 } tnBfdAdminTemplateMultiplier OBJECT-TYPE SYNTAX Unsigned32 (3..20) MAX-ACCESS read-create STATUS current DESCRIPTION "The value of tnBfdAdminTemplateMultiplier specifies the number of consecutive BFD messages that must be missed from the peer before the BFD session state is changed to down and the upper level protocols (OSPF, IS-IS or PIM) are notified of the fault." DEFVAL { 3 } ::= { tnBfdAdminTemplateEntry 5 } tnBfdAdminTemplateEchoRxInt OBJECT-TYPE SYNTAX Unsigned32 (100..100000) UNITS "milliseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "The value of tnBfdAdminTemplateEchoRxInt specifies the minimum echo recieve interval for a BFD session." DEFVAL { 100 } ::= { tnBfdAdminTemplateEntry 6 } tnBfdAdminTemplateType OBJECT-TYPE SYNTAX INTEGER { cpmNp(1), auto(2), iomHw(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "The value of tnBfdAdminTemplateType specifies the configured termination of a BFD session. The value of 'cpmNp(1)' specifies termination on the CPM card's Network Processor. The value of 'auto(2)' specifies a system-selected termination other than the CPM Network Processor." DEFVAL { auto } ::= { tnBfdAdminTemplateEntry 7 } -- -- BFD template operational value objects -- tnBfdOperValueObjects OBJECT IDENTIFIER ::= { tnBfdOperObjects 1 } tnBfdOperTemplateTable OBJECT-TYPE SYNTAX SEQUENCE OF TmnxBfdOperTemplateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Operational value table for BFD templates." ::= { tnBfdOperValueObjects 1 } tnBfdOperTemplateEntry OBJECT-TYPE SYNTAX TmnxBfdOperTemplateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular BFD template. Entries are created by user via tnBfdAdminTemplateTable. Entries are deleted by user via tnBfdAdminTemplateTable." INDEX { tnSysSwitchId, tnBfdOperTemplateName } ::= { tnBfdOperTemplateTable 1 } TmnxBfdOperTemplateEntry ::= SEQUENCE { tnBfdOperTemplateName TNamedItem, tnBfdOperTemplateRowStatus RowStatus, tnBfdOperTemplateTxInt Unsigned32, tnBfdOperTemplateRxInt Unsigned32, tnBfdOperTemplateMultiplier Unsigned32, tnBfdOperTemplateEchoRxInt Unsigned32, tnBfdOperTemplateType INTEGER } tnBfdOperTemplateName OBJECT-TYPE SYNTAX TNamedItem MAX-ACCESS not-accessible STATUS current DESCRIPTION "The name of this BFD template that uniquely identifies an entry in this table." ::= { tnBfdOperTemplateEntry 1 } tnBfdOperTemplateRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RowStatus for this row. Values read will only be active(1). To create or destroy entries in this table, use the tnBfdAdminTemplateEntry." ::= { tnBfdOperTemplateEntry 2 } tnBfdOperTemplateTxInt OBJECT-TYPE SYNTAX Unsigned32 (10..100000) UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of tnBfdOperTemplateTxInt indicates the transmit timers for the BFD packets." ::= { tnBfdOperTemplateEntry 3 } tnBfdOperTemplateRxInt OBJECT-TYPE SYNTAX Unsigned32 (10..100000) UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of tnBfdOperTemplateTxInt indicates the recieve timers for the BFD packets." ::= { tnBfdOperTemplateEntry 4 } tnBfdOperTemplateMultiplier OBJECT-TYPE SYNTAX Unsigned32 (3..20) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of tnBfdOperTemplateMultiplier indicates the number of consecutive BFD messages that must be missed from the peer before the BFD session state is changed to down and the upper level protocols (OSPF, IS-IS or PIM) are notified of the fault." ::= { tnBfdOperTemplateEntry 5 } tnBfdOperTemplateEchoRxInt OBJECT-TYPE SYNTAX Unsigned32 (100..100000) UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of tnBfdOperTemplateEchoRxInt indicates the minimum echo recieve interval for a BFD session." ::= { tnBfdOperTemplateEntry 6 } tnBfdOperTemplateType OBJECT-TYPE SYNTAX INTEGER { cpmNp(1), auto(2), iomHw(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of tnBfdOperTemplateType indicates the configured termination of a BFD session. The value of 'cpmNp(1)' specifies termination on the CPM card's Network Processor. The value of 'auto(2)' specifies a system-selected termination other than the CPM Network Processor." ::= { tnBfdOperTemplateEntry 7 } -- ---------------------------------------------- -- Compliance Statements -- ---------------------------------------------- -- tnBfdV11v0Compliance MODULE-COMPLIANCE -- STATUS current -- DESCRIPTION -- "The compliance statement for management of BFD features on version 11.0 -- of the Nokia SROS series systems." -- MODULE -- MANDATORY-GROUPS { -- tnBfdV11v0Group -- } -- ::= { tnBfdCompliances 1 } -- ------------------------------------------ -- Units of Conformance -- ------------------------------------------ -- tnBfdV11v0Group OBJECT-GROUP -- OBJECTS { -- tnBfdAdminOwner, -- tnBfdAdminControlApply, -- tnBfdAdminLastSetTimer, -- tnBfdAdminLastSetTimeout, -- tnBfdAdminTemplateRowStatus, -- tnBfdAdminTemplateTxInt, -- tnBfdAdminTemplateRxInt, -- tnBfdAdminTemplateMultiplier, -- tnBfdAdminTemplateEchoRxInt, -- tnBfdAdminTemplateType, -- tnBfdOperTemplateRowStatus, -- tnBfdOperTemplateTxInt, -- tnBfdOperTemplateRxInt, -- tnBfdOperTemplateMultiplier, -- tnBfdOperTemplateEchoRxInt, -- tnBfdOperTemplateType -- -- } -- STATUS current -- DESCRIPTION -- "The group of objects supporting management of BFD features on version -- 11.0 of the Nokia SROS series systems." -- ::= { tnBfdGroups 1 } -- -- Dummy Scalar -- tnBfdAdminValueScalar1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "A dummy scalar that satisfies a SNMP get request quickly.Otherwise, it has to traverse the remaining MIB to get to the next applicable item." ::= { tnBfdAdminValueObjects 101 } tnBfdAdminValueScalar2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "." ::= { tnBfdAdminValueObjects 102 } END