-- ======================================================================= -- File : osSyncE.mib -- Description : Private MIB support the functionality of -- Syncrouneous Ethernet (SyncE). -- By : Aviad -- Copyright (c) 2008 MRV. All Rights Reserved. -- -- -- Reproduction of this document is authorized on condition that this -- copyright notice is included. This MRV SNMP MIB Specification -- embodies MRV's proprietary intellectual property. MRV -- retains all title and ownership in the specification, including any -- revisions. -- -- It is MRV's intent to encourage the widespread use of this -- specification in connection with the management of MRV's -- products. MRV grants vendor, end-users, and other interested -- parties a non-exclusive license to use this specification in -- connection with the management of MRV's products. -- -- This specification is supplied "AS IS," and MRV makes no -- warranty, either express or implied, as to the use, operation, -- condition, or performance of the specification. -- -- Copyright text courtesy of MRV -- -- If you have any questions about this MIB, please call MRV -- Technical Support Center at 1-800-858-7815 from inside USA or -- 1-818-773-0900 from outside USA. -- -- -- MRV retains the right to change this MIB without notification. OS-SYNCE-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, enterprises, Integer32 FROM SNMPv2-SMI DisplayString, TruthValue FROM SNMPv2-TC oaOptiSwitch FROM OS-COMMON-TC-MIB MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF; osSyncEMIB MODULE-IDENTITY LAST-UPDATED "201208150000Z" -- Aug 15, 2012 ORGANIZATION "MRV Communications, Inc." CONTACT-INFO "Aviad Itzcovitch MRV Communication, Inc http://www.mrv.com Email: AItzcovitch@mrv.com" DESCRIPTION "MRV Configuration of The MIB module for PTP version 2 (IEEE Std. 1588(TM)-2008)" -- Revision history -- ================ REVISION "201208150000Z" -- Aug 15, 2012 DESCRIPTION "Initial edition." ::= { oaOptiSwitch 23 } -- ************************************************************ -- Textual conventions -- ************************************************************ -- ************************************************************ -- MIB place Definition -- ************************************************************ osSyncEMIBNotifs OBJECT IDENTIFIER ::= { osSyncEMIB 0 } osSyncEMIBObjects OBJECT IDENTIFIER ::= { osSyncEMIB 1 } osSyncEMIBInfo OBJECT IDENTIFIER ::= { osSyncEMIBObjects 1 } osSyncEMIBCfg OBJECT IDENTIFIER ::= { osSyncEMIBObjects 2 } osSyncEMIBCapabilities OBJECT IDENTIFIER ::= { osSyncEMIBCfg 1 } osSyncEMIBCfgGen OBJECT IDENTIFIER ::= { osSyncEMIBCfg 2 } osSyncEMIBEventParams OBJECT IDENTIFIER ::= { osSyncEMIBInfo 1 } osSyncEMIBConformance OBJECT IDENTIFIER ::= { osSyncEMIB 101 } osSyncEMIBCompliances OBJECT IDENTIFIER ::= { osSyncEMIBConformance 1 } osSyncEMIBGroups OBJECT IDENTIFIER ::= { osSyncEMIBConformance 2 } -- ************************************************************ -- Objects Identifiers Definition -- ************************************************************ osSyncEMIBSupport OBJECT-TYPE SYNTAX INTEGER { notSupported(1), supported(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value supported(2) indicates that the device supports network clocks." ::= { osSyncEMIBCapabilities 1 } osSyncEStatus OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable SyncE protocol." DEFVAL { false } ::= {osSyncEMIBCfgGen 1 } osSyncET1CableType OBJECT-TYPE SYNTAX INTEGER { lengthNotApplicable (0), length0To133 (1), length134To266 (2), length267To399 (3), length400To533 (4), length534To655 (5), lboNeg7p5dB (6), lboNeg15p0dB (7), lboNeg22p5dB (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "osSyncET1CableType applies both to a ds1 port configured with a short buildout (1-6) and for long buildout (7-9). Short buildout is bescribed bythe length of the line (in feet). For line lengths longer than 655 feet the ds1 buildout is long. Long buildout is described in decibels(dB) the transmission signal decreases over the line. For long buildout the following values are valid: lboNeg7p5dB - For -7.5 dB lboNeg15p0dB - For -15.0 dB lboNeg22p5dB - For -22.5 dB For short buildout the following values are valid: length0To133 - For line length from 0 to 133 feet (0.0dB) length134To266 - For line length from 134 to 266 feet (0.5dB) length267To399 - For line length from 267 to 399 feet (0.8dB) length400To533 - For line length from 400 to 533 feet (1.1dB) length534To655 - For line length from 534 to 655 feet (1.5dB)" REFERENCE "CLI command 'ds1e1 type t1 (133ft|266ft|399ft|533ft|655ft|-7.5db|-15db|-22.5db)'" DEFVAL { lengthNotApplicable } ::= { osSyncEMIBCfgGen 2 } osSyncEDs1e1Type OBJECT-TYPE SYNTAX INTEGER { notSet(0), square1544(1), square2048(2), typeE1(3), typeJ1(4), typeT1(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "the value of osSyncEDs1e1Type indicates whether the DS1e1 signal is in T1, E1 or J1 mode. in addition, a square signal of 1544 or 2048 (that can be derived from the triatri-signal of e1,t1 ot j1)" REFERENCE "CLI command 'ds1e1 type (1.544MHz|2.048MHz|e1|j1|t1)'" DEFVAL { notSet } ::= { osSyncEMIBCfgGen 3 } osSyncEDs1e1Connect OBJECT-TYPE SYNTAX INTEGER { notSet(0), sec (1), ssu (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "sec: Connectivity to SDH Equipment Clock ssu: Connectivity to Synchronization Supply Unit" REFERENCE "CLI command 'ds1e1 connect (ssu|sec)'" DEFVAL { notSet } ::= { osSyncEMIBCfgGen 4 } osSyncEFrequencyClkIn OBJECT-TYPE SYNTAX INTEGER { notSet(0), frequency1544KHz (4), frequency2048KHz (5), frequency6480KHz (6), frequency19440KHz (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "frequency of the BNC input signal ClkIn." DEFVAL { notSet } ::= { osSyncEMIBCfgGen 5 } osSyncEFrequencyClkOut OBJECT-TYPE SYNTAX INTEGER { notSet(0), frequency2KHz (1), frequency4KHz (2), frequency8KHz (3), frequency1544KHz (4), frequency2048KHz (5), frequency6480KHz (6), frequency19440KHz (7), ptp (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "frequency of the BNC output signal ClkOut ptp: connect the ptpOut signal to the clkOut BNC" DEFVAL { notSet } ::= { osSyncEMIBCfgGen 6 } osSyncEFrequencyPtp OBJECT-TYPE SYNTAX INTEGER { notSet(0), frequency1544KHz (1), frequency2048KHz (2), frequency6480KHz (3), frequency19440KHz (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "frequency of the BNC input signal ClkIn" DEFVAL { notSet } ::= { osSyncEMIBCfgGen 7 } osSyncELineCode OBJECT-TYPE SYNTAX INTEGER { notSet(0), ami(1), hdb3(2), b8zs(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable describes the variety of Zero Code Suppression used on the link, which in turn affects a number of its characteristics. It should be set to match the carrier. AMI (alternate mark inversion) refers to a mode wherein no zero code suppression is present and the line encoding does not solve the problem directly. In this application, the higher layer must provide data which meets or exceeds the pulse density requirements, such as inverting HDLC data. This could be used for T1 or E1 lines. B8ZS refers to the use of a specified pattern of normal bits and bipolar violations which are used to replace a sequence of eight zero bits. This can be used on T1 lines while HDB3 provides similar functionality for E1 links." REFERENCE "CLI command 'ds1e1 linecode (ami|hdb3|b8zs)'" DEFVAL { notSet } ::= { osSyncEMIBCfgGen 8 } osSyncEFreeRunMode OBJECT-TYPE SYNTAX INTEGER { dnu(1), eec(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Free-run mode is one that has not beem syncronized to a clock source. eec: EEC1 or EEC2 quality level as defined by ITU-T G.781 dnu: Do not use me (quality level 15)" REFERENCE "CLI command 'freerun-mode (eec|dnu)'" DEFVAL { dnu } ::= { osSyncEMIBCfgGen 9 } -- ************************************************************ -- SyncE Clock Source Table -- ************************************************************ osSyncEClockSourceTable OBJECT-TYPE SYNTAX SEQUENCE OF OsSyncEClockSourceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of clock sources for SyncE" ::= { osSyncEMIBCfg 3 } osSyncEClockSourceEntry OBJECT-TYPE SYNTAX OsSyncEClockSourceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table contains a SyncE clock source." INDEX { osSyncEClockSourceEntryId } ::= { osSyncEClockSourceTable 1 } OsSyncEClockSourceEntry ::= SEQUENCE { osSyncEClockSourceEntryId Integer32, osSyncEClockSourceEntryType INTEGER, osSyncEClockSourceEthPortNum Integer32, osSyncEClockSourceEthPriority Integer32, osSyncEClockSourceE1QL INTEGER, osSyncEClockSourceT1QL INTEGER, osSyncEClockSourceJ1QL INTEGER } osSyncEClockSourceEntryId OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "." ::= { osSyncEClockSourceEntry 1 } osSyncEClockSourceEntryType OBJECT-TYPE SYNTAX INTEGER { clkIn (1), ds1e1 (2), ptp (3), ethPort (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "clock source entry type." ::= { osSyncEClockSourceEntry 2 } osSyncEClockSourceEthPortNum OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Port of the entry. 0 value indicates invalid entry." ::= { osSyncEClockSourceEntry 3 } osSyncEClockSourceEthPriority OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "port priority to be selected from the range 0 to 126 0: do not use 1: highest priority 127: lowest priority (default)" DEFVAL { 127 } ::= { osSyncEClockSourceEntry 4 } osSyncEClockSourceE1QL OBJECT-TYPE SYNTAX INTEGER { prc (2), ssuA (4), ssuB (8), eec1 (11), dnu (15), notDefined (127) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the QL of the clock source assuming it is E1." DEFVAL { notDefined } ::= { osSyncEClockSourceEntry 5 } osSyncEClockSourceT1QL OBJECT-TYPE SYNTAX INTEGER { stu (0), prs (1), tnc (4), st2 (7), st3 (10), st3e (13), prov (14), dnu (15), notDefined (127) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the QL of the clock source assuming it is T1." DEFVAL { notDefined } ::= { osSyncEClockSourceEntry 6 } osSyncEClockSourceJ1QL OBJECT-TYPE SYNTAX INTEGER { unk (0), eec1 (11), notDefined (127) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the QL of the clock source assuming it is j1." DEFVAL { notDefined } ::= { osSyncEClockSourceEntry 7 } osSyncEEventDescription OBJECT-TYPE SYNTAX DisplayString (SIZE(0..120)) MAX-ACCESS read-only STATUS current DESCRIPTION "SyncE Event Description. Default description : 'Alarm: '" ::= { osSyncEMIBEventParams 1 } -- ****************************************************************** -- NOTIFICATIONS (TRAPS) -- These notifications will be sent to the management entity -- whenever a MEP loses/restores contact with one or more other MEPs. -- ****************************************************************** osSyncEClockAlarmLock NOTIFICATION-TYPE OBJECTS { osSyncEClockSourceEntryType } STATUS current DESCRIPTION "Network Clock Lock (synchronization) alarm to specific source; osSyncEClockSourceEntryType is the part of osSyncEClockSourceEntry (osSyncEClockSourceTable) osSyncEClockSourceEntryId - Also the index clock source table (osSyncEClockSourceTable), it is number of Ethernet ports or some code for ds1e1/LIU, SMB. " REFERENCE "ABC." ::= { osSyncEMIBNotifs 1 } osSyncEClockAlarmUnLock NOTIFICATION-TYPE OBJECTS { osSyncEClockSourceEntryType } STATUS current DESCRIPTION "Network Clock UnLock (de-synchronisation) alarm to specific source; osSyncEClockSourceEntryType is the part of osSyncEClockSourceEntry (osSyncEClockSourceTable) osSyncEClockSourceEntryId - Also the index clock source table (osSyncEClockSourceTable), it is the number of Ethernet ports or some code for ds1e1/LIU, SMB. " REFERENCE "ABC." ::= { osSyncEMIBNotifs 2 } osSyncEPtpAlarmLock NOTIFICATION-TYPE OBJECTS { osSyncEEventDescription } STATUS current DESCRIPTION "PTP (1588) state is Lock. " REFERENCE "ABC." ::= { osSyncEMIBNotifs 3 } osSyncEPtpAlarmUnLock NOTIFICATION-TYPE OBJECTS { osSyncEEventDescription } STATUS current DESCRIPTION "PTP (1588) state is UnLock. " REFERENCE "ABC." ::= { osSyncEMIBNotifs 4 } --- ******************************************************************* --- Compliance statements --- ******************************************************************* osSyncEMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The core compliance statement for all the implementations." MODULE -- this module MANDATORY-GROUPS { osSyncEMibMandatoryGroup, osSyncEMIBNotificationsGroup } ::= { osSyncEMIBCompliances 1 } --- ******************************************************************* --- Conformance Groups --- ******************************************************************* osSyncEMibMandatoryGroup OBJECT-GROUP OBJECTS { osSyncEMIBSupport, osSyncEStatus, osSyncET1CableType, osSyncEDs1e1Type, osSyncEDs1e1Connect, osSyncEFrequencyClkIn, osSyncEFrequencyClkOut, osSyncEFrequencyPtp, osSyncELineCode, osSyncEFreeRunMode, osSyncEEventDescription, osSyncEClockSourceEntryType, osSyncEClockSourceEthPortNum, osSyncEClockSourceEthPriority, osSyncEClockSourceE1QL, osSyncEClockSourceT1QL, osSyncEClockSourceJ1QL } STATUS current DESCRIPTION "." ::= { osSyncEMIBGroups 1 } osSyncEMIBNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { osSyncEClockAlarmLock, osSyncEClockAlarmUnLock, osSyncEPtpAlarmLock, osSyncEPtpAlarmUnLock } STATUS current DESCRIPTION "Objects for the Notifications group." ::= { osSyncEMIBGroups 2 } END