-- ======================================================================= -- File : oaSwitch.mib -- Description : Private MIB for Device Layer-2 Configuration -- By : Alex & Yakov & Ludmila -- Version : $Revision: 1.1.1.1 $ -- Date : $Date: 2002/03/19 13:41:55 $ -- $Log: oaSwitch.mib,v $ -- Revision 1.1.1.1 2002/03/19 13:41:55 alex -- Version 4.2.3 -- -- Revision 1.1.1.1 2002/03/10 11:52:43 alex -- Version 4.2.3 (For CERT report reasons) -- -- Revision 1.3 2001/04/12 07:14:03 lolshansky -- Words "NBase" have been changed with words "Optical Access" -- -- Revision 1.2 2001/02/27 08:01:55 alex -- File header (Version, Data, Log, Copyright, etc.) -- -- Revision 1.1 2001/02/15 14:53:57 alex -- Common mibs for OptiSwitch & OSM -- -- ======================================================================= -- -- -- Copyright (c) 2000 Optical Access. All Rights Reserved. -- -- Reproduction of this document is authorized on condition that this -- copyright notice is included. This Optical Access SNMP MIB Specification -- embodies Optical Access's proprietary intellectual property. Optical Access -- retains all title and ownership in the specification, including any -- revisions. -- -- It is Optical Access's intent to encourage the widespread use of this -- specification in connection with the management of Optical Access's -- products. Optical Access grants vendor, end-users, and other interested -- parties a non-exclusive license to use this specification in -- connection with the management of Optical Access's products. -- -- This specification is supplied "AS IS," and Optical Access makes no -- warranty, either express or implied, as to the use, operation, -- condition, or performance of the specification. -- -- Optical Access retains the right to change this MIB without notification. OASWITCH-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI DisplayString FROM RFC1213-MIB Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; MacAddress ::= OCTET STRING(SIZE(6)) -- ************************************************************ -- Object Identifier Definition. -- ************************************************************ oaccess OBJECT IDENTIFIER ::= { enterprises 6926 } oaManagement OBJECT IDENTIFIER ::= { oaccess 1 } oaSwitch OBJECT IDENTIFIER ::= { oaManagement 5 } -- ************************************************************* -- MAC Address Table of the Device. -- ************************************************************* oaSwitchMac OBJECT IDENTIFIER ::= { oaSwitch 1 } oaSwitchMacInfo OBJECT IDENTIFIER ::= { oaSwitchMac 1 } oaSwitchMacInfoNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current number of entries in the learning table." ::= { oaSwitchMacInfo 1 } oaSwitchMacInfoMaxNumbr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of entries in the learning table." ::= { oaSwitchMacInfo 2 } oaSwitchMacInfoClear OBJECT-TYPE SYNTAX INTEGER { none (1), clear (2) } ACCESS read-write STATUS mandatory DESCRIPTION "GET always returns 'none (1)'. SET 'clear(2)' couses LT erasing. GET always returns 'none (1)'. WARNING: erasing LT on some kind of agents may couse disconnection for short period of time." ::= { oaSwitchMacInfo 5 } oaSwMacTable OBJECT-TYPE SYNTAX SEQUENCE OF OaSwMacEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains Learning Table with fields that does not exsist in dot1dTpFdbTable." ::= { oaSwitchMac 2 } oaSwMacEntry OBJECT-TYPE SYNTAX OaSwMacEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about a specific MAC address in the oaSwMacTable." INDEX { oaSwMacAddr, oaSwMacVid} ::= { oaSwMacTable 1 } OaSwMacEntry ::= SEQUENCE { oaSwMacAddr MacAddress, oaSwMacVid INTEGER, oaSwMacVidx INTEGER, oaSwMacGetViewIndex INTEGER, oaSwMacPort INTEGER, oaSwMacMode INTEGER, oaSwMacTagged INTEGER, oaSwMacPriority INTEGER, oaSwMacFlags INTEGER, oaSwMacStatus INTEGER } oaSwMacAddr OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "MAC address for which the bridge has forwarding and/or filtering information." ::= { oaSwMacEntry 1 } oaSwMacVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Tag of the entry: the address 'Address recognition' is concatenation of oaSwMac and oaSwMacVid. When ISVP is not implemented or ISVL mode is disabled, this field in SET/NEXT operations may have any value, GET operation should return 0." ::= { oaSwMacEntry 2 } oaSwMacVidx OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Outbound VLAN tag: if frame 'Address recognition' was resolved with this entry, the forwarding will be maked according the VLAN with this tag. When ISVP is not implemented or ISVL mode is disabled, this field in SET operations may have any value, GET operation should return 0." ::= { oaSwMacEntry 6 } oaSwMacGetViewIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Sequantial index of the entry." ::= { oaSwMacEntry 8 } oaSwMacPort OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port of the entry. '0' value indicates that the port number has not been learned but that the bridge does have some forwarding/filtering information about this address. Another words, the frame will be forwarding 'to the CPU only' and the bridge will sovle, what it must be done with this frame." ::= { oaSwMacEntry 9 } oaSwMacMode OBJECT-TYPE SYNTAX INTEGER { other (1), dynamic (2), static (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Status of the entry: Only 'dynamic (2)' entries are aged." ::= { oaSwMacEntry 20 } oaSwMacTagged OBJECT-TYPE SYNTAX INTEGER { no (0), yes (1) } ACCESS read-write STATUS mandatory DESCRIPTION "'Tagged' state of the entry. When ISVP is not implemented or ISVL mode is disabled, this field in SET operations may have any value, GET operation should return 0." ::= { oaSwMacEntry 21 } oaSwMacPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Controls the priority level of this entry" ::= { oaSwMacEntry 22 } oaSwMacFlags OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specific flags for MAC entry: 0x0001 - Router Entry" ::= { oaSwMacEntry 23 } oaSwMacStatus OBJECT-TYPE SYNTAX INTEGER { valid (1), invalid (2) } ACCESS read-write STATUS mandatory DESCRIPTION "State of the entry: Only 'valid(1)' entries participate in the forwarding/filtering process. The new entry is created when PDU with oaSwMacStatus=valid(1), oaSwMac, oaSwMacVid and optionally oaSwMacPort (default '0'), oaSwMacVidx (default oaSwMacVid) and oaSwMacMode comes. If {oaSwMac,oaSwMacVid} exists, the bridge replaces it. The old entry is deleted when PDU with oaSwMacStatus=invalid(2), oaSwMac, oaSwMacVid comes. The old entry is modified when PDU with oaSwMac, oaSwMacVid and new value of fields oaSwMacPort and/or oaSwMacVidx and/or oaSwMacMode comes." ::= { oaSwMacEntry 30 } -- ************************************************************ -- The oaSysFrmGen Subgroup -- -- Implementation of the oaSysFrmGen subgroup is optional for -- Nbase products that do not implement a frame generator - like the -- NH204. -- -- The oaSysFrmGen Group is used by a station to initiate an Ethernet -- traffic flow from this agent to the address denoted by oaSysFrmGenDa. -- -- To start a Frame Generator session, you must set the objects: -- oaSysFrmGenDa, oaSysFrmGenSa, oaSysFrmGenPktLen, oaSysFrmGenPktFill, -- oaSysFrmGenPktRate, oaSysFrmGenDestMap & oaSysFrmGenPktNum. -- The defaults are: -- oaSysFrmGenDa = loopback address, oaSysFrmGenSa = device address, -- oaSysFrmGenPktLen = 60, oaSysFrmGenPktFill = 0, -- oaSysFrmGenPktRate = 1, oaSysFrmGenPktNum = 0 ( forever ) -- oaSysFrmGenPriority =1, oaSysFrmGenVlanId = 0 -- -- Note: Only one Frame Generator session can be activated at a time. -- -- ************************************************************ oaSysFrmGen OBJECT IDENTIFIER ::= { oaSwitch 3 } oaSysFrmGenSession OBJECT-TYPE SYNTAX INTEGER{ idleFG (1), -- The Frame Generator Session is idle(GET) -- or stop the Frame Generator(SET). runFG (2) -- The Frame Generator Session is running(GET) -- or start a Frame Generator Session(SET) } ACCESS read-write STATUS mandatory DESCRIPTION "This object controls the activity of the Frame Generator process." ::= { oaSysFrmGen 1 } oaSysFrmGenDa OBJECT-TYPE SYNTAX MacAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Frame Generator Destination MAC Address." DEFVAL { '000000000000'h } ::= { oaSysFrmGen 2 } oaSysFrmGenSa OBJECT-TYPE SYNTAX MacAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Frame Generator Source MAC Address." DEFVAL { '000000000000'h } ::= { oaSysFrmGen 3 } oaSysFrmGenPktFill OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Frame Generator Packet Fill Pattern. The default is 0." ::= { oaSysFrmGen 4 } oaSysFrmGenPktRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Frame Generator Rate, meaning the number of packets per second to be generated. Each device is able to generate a certain number of packets/second. Default is 1 packet/second" ::= { oaSysFrmGen 5 } oaSysFrmGenDestMap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The Frame Generator Destination Map = the set of ports to which the generated packets are to be sent. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the switch is represented by a single bit within the value of this object. If that bit has a value of <1> then that port is included in the set of ports; the port is not included if its bit has a value of <0>. (Note that the setting of the bit corresponding to the port from which a frame is received is irrelevant.) The default value of this object is a string of ones of appropriate length." ::= { oaSysFrmGen 6} oaSysFrmGenPktNum OBJECT-TYPE SYNTAX Counter ACCESS read-write STATUS mandatory DESCRIPTION "The Frame Generator Number of Packets to be generated. Default is 1." ::= { oaSysFrmGen 7 } oaSysFrmGenPktLen OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Frame Generator Packet Length. Default is 60 bytes" ::= { oaSysFrmGen 8 } oaSysFrmGenXmtPktNum OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Packets transmitted by the The Frame Generator." ::= { oaSysFrmGen 9 } oaSysFrmGenPriority OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-write STATUS mandatory DESCRIPTION "The Frame Generator packet priority. This value determines the priority level at which the generated packet will be transmitted. For tagged packets the VPT field in the vlan header will be assigned according to this value." DEFVAL { 1 } ::= { oaSysFrmGen 10 } oaSysFrmGenVlanId OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "A 12 bit VLAN Identifier to be set in the PVID field of the packet. 0 - Used when the packet should contains no vlan Header." DEFVAL { 0 } ::= { oaSysFrmGen 11 } END