-- ======================================================================= -- File : oaAps.mib -- Description : Private MIB for APS supporting modules in Lambda Driver (DWDM/CWDM) -- -- By : Maoz -- Version : Revision: 1.2 -- Original Date : September 15, 2011 -- Last Change : Date: July 30, 2012 -- ======================================================================= -- -- -- Copyright (c) 2001 MRV. All Rights Reserved. -- -- Reproduction of this document is authorized on condition that this -- copyright notice is included. This MRV SNMP MIB Specification -- embodies MRV proprietary intellectual property. MRV -- retains all title and ownership in the specification, including any -- revisions. -- -- It is MRV's intent to encourage the widespread use of this -- specification in connection with the management of MRV's -- products. MRV grants vendor, end-users, and other interested -- parties a non-exclusive license to use this specification in -- connection with the management of MRV's products. -- -- This specification is supplied "AS IS," and MRV makes no -- warranty, either express or implied, as to the use, operation, -- condition, or performance of the specification. -- -- MRV retains the right to change this MIB without notification. -- OA-APS-MIB DEFINITIONS ::= BEGIN IMPORTS DisplayString FROM RFC1213-MIB MODULE-IDENTITY, OBJECT-TYPE, Gauge32, enterprises, Integer32 FROM SNMPv2-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF; ------------------------------------------------------------------------------ -- Object Identifier Definition ------------------------------------------------------------------------------ oaApsMIB MODULE-IDENTITY LAST-UPDATED "201207300000Z" -- Jul 30, 2012 ORGANIZATION "MRV Communications, Inc." CONTACT-INFO "Maoz Yona MRV Communication, Inc http://www.mrv.com Email: myona@mrv.com " DESCRIPTION "This management information module supports the configuration and management of the OTN-APS functionality." -- Revision history REVISION "201207300000Z" -- Jul 30, 2012 DESCRIPTION "Revision 1.2: Changes: 1. Improved Descriptions of the MIB Objects." REVISION "201202070000Z" -- Feb 07, 2012 DESCRIPTION "Revision 1.1: Changes: 1. New object [oaApsModeVersion] added to the [oaApsModeConfigEntry]. 2. New objects [oaApsConfigGroupCmdSwitchStatus] and [oaApsConfigGroupWorkingLineDefect] and [oaApsConfigGroupProtectLineDefect] are added to the [oaApsConfigGroupEntry]. 3. Unusable MIB's Node [oaApsMIBObjects] removed from the MIB's Tree. 4. Few MIB Object's syntax changed from INTEGER to Integer32." REVISION "201109150000Z" -- Sep 15, 2011 DESCRIPTION "Revision 1.0: Initial edition." ::= { oaLambdaDriver 20 } ------------------------------------------------------------------------------ -- MIB place Definition ------------------------------------------------------------------------------ oaccess OBJECT IDENTIFIER ::= { enterprises 6926 } oaManagement OBJECT IDENTIFIER ::= { oaccess 1 } oaLambdaDriver OBJECT IDENTIFIER ::= { oaManagement 41 } oaApsConfig OBJECT IDENTIFIER ::= { oaApsMIB 1 } oaApsMIBNotifications OBJECT IDENTIFIER ::= { oaApsMIB 2 } oaApsMIBConformance OBJECT IDENTIFIER ::= { oaApsMIB 3 } ------------------------------------------------------------------------------ -- Textual conventions ------------------------------------------------------------------------------ ApsSwitchCommand ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An Aps switch command allows a user to perform protection switch actions. The Switch command values are: noCmd This value should be returned by a read request when no switch command has been written to the object in question since initialization. This value may not be used in a write operation. clear Clears all of the switch commands listed below for the specified group. lockoutOfProtection Prevents the working line port from switching to the protection line port, thus preventing any further APS switchovers for any reason, including manual or forced switchovers and signal failures. forcedSwitchWorkToProtect Switches the working line to the protection line, if no lockout is in effect regardless of the status of the signal. forcedSwitchProtectToWork Switches the protected line to the working line, if no lockout is in effect regardless of the status of the signal. manualSwitchWorkToProtect Switches the working line to the protection line, if the signal is good and no lockout is in effect. manualSwitchProtectToWork Switches the protected line to the working line, if the signal is good and no lockout is in effect." SYNTAX INTEGER { noCmd(1), clear(2), lockoutOfProtection(3), forcedSwitchWorkToProtect(4), forcedSwitchProtectToWork(5), manualSwitchWorkToProtect(6), manualSwitchProtectToWork(7) } ------------------------------------------------------------------------------ -- APS Mode Configuration Table ------------------------------------------------------------------------------ oaApsModeConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF OaApsModeConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The APS Mode Configuration Table." ::= { oaApsConfig 1 } oaApsModeConfigEntry OBJECT-TYPE SYNTAX OaApsModeConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the APS Configuration table." INDEX { oaApsModeConfigSlotIndex } ::= { oaApsModeConfigTable 1 } OaApsModeConfigEntry ::= SEQUENCE { oaApsModeConfigSlotIndex Integer32, oaApsModeConfigMode INTEGER, oaApsModeConfigRevert INTEGER, oaApsModeConfigWaitToRestore Integer32, oaApsModeConfigGroups Gauge32, oaApsModeVersion Integer32 } oaApsModeConfigSlotIndex OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The slot#. An index from 1 to The number of slots." ::= { oaApsModeConfigEntry 1 } oaApsModeConfigMode OBJECT-TYPE SYNTAX INTEGER { noAps(1), apsProtect(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "APS global mode. noAps - APS is disabled. apsProtect - APS is enabled." ::= { oaApsModeConfigEntry 2 } oaApsModeConfigRevert OBJECT-TYPE SYNTAX INTEGER { nonRevertive(1), revertive(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The revertive mode of APS. nonRevertive Traffic remains on the protection line until another switch request is received. revertive When the condition that caused a switch to the protection line has been cleared the signal is switched back to the working line." DEFVAL { nonRevertive } ::= { oaApsModeConfigEntry 3 } oaApsModeConfigWaitToRestore OBJECT-TYPE SYNTAX Integer32 (0..720) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "The Wait To Restore period in seconds. This field only applies if revertive mode is enabled, otherwise this value is ignored. After clearing of a condition that caused an automatic switch, the wait to restore period must elapse before reverting." DEFVAL { 300 } ::= { oaApsModeConfigEntry 4 } oaApsModeConfigGroups OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of APS groups. This count includes all rows in ApsModeConfigTable." ::= { oaApsModeConfigEntry 5 } oaApsModeVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "APS version. Starts from value '2'. Indicates the APS version used in the Module. APS version should be updated upon any change of implementation." ::= { oaApsModeConfigEntry 6 } ------------------------------------------------------------------------------ -- APS Groups Configuration Table ------------------------------------------------------------------------------ oaApsConfigGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF OaApsConfigGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The APS Groups Configuration table. If OTN Module is working in the Topology Mode 'BiDirectional' 4 groups exist. Each group relates to one of the 4 ODU-1 entries. If OTN Module is working in the Topology Mode 'UniDirectional' 2 groups exist. First group relates to the 1-st Line Port of the OTN Module and second group relates to the 2-nd Line Port of this Module." ::= { oaApsConfig 5 } oaApsConfigGroupEntry OBJECT-TYPE SYNTAX OaApsConfigGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the APS Groups Configuration table." INDEX { oaApsConfigGroupSlotIndex, oaApsConfigGroupId } ::= { oaApsConfigGroupTable 1 } OaApsConfigGroupEntry ::= SEQUENCE { oaApsConfigGroupSlotIndex Integer32, oaApsConfigGroupId Integer32, oaApsConfigGroupName DisplayString, oaApsConfigGroupPortMembers OCTET STRING, oaApsConfigGroupWorkingLinePort Integer32, oaApsConfigGroupProtectLinePort Integer32, oaApsConfigGroupWorkingStatus INTEGER, oaApsConfigGroupProtectStatus INTEGER, oaApsConfigGroupCmdSwitchTrans ApsSwitchCommand, oaApsConfigGroupCmdSwitchRec ApsSwitchCommand, oaApsConfigGroupCmdSwitchStatus ApsSwitchCommand, oaApsConfigGroupWorkingLineDefect BITS, oaApsConfigGroupProtectLineDefect BITS } oaApsConfigGroupSlotIndex OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The slot#. An index from 1 to The number of slots." ::= { oaApsConfigGroupEntry 1 } oaApsConfigGroupId OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the APS group." ::= { oaApsConfigGroupEntry 2 } oaApsConfigGroupName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual name for the APS group." ::= { oaApsConfigGroupEntry 3 } oaApsConfigGroupPortMembers OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "List of access ports belonging to that group." ::= { oaApsConfigGroupEntry 4 } oaApsConfigGroupWorkingLinePort OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of working line-port (wdm-trunk)." ::= { oaApsConfigGroupEntry 5 } oaApsConfigGroupProtectLinePort OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of protected line-port (wdm-trunk)." ::= { oaApsConfigGroupEntry 6 } oaApsConfigGroupWorkingStatus OBJECT-TYPE SYNTAX INTEGER { inActive(1), active(2), standBy(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the working line-port (wdm-trunk). inActive - Line port is not operational. active - Line port is operational. For BiDirectional mode both Rx & Tx belong to the working channel, For UniDirectional mode only the Rx or the Tx fiber belongs to the working channel. standBy - Line port is operational but in standBy mode. For BiDirectional mode both Rx & Tx belong to the working channel, For UniDirectional mode only the Rx or the Tx fiber belongs to the working channel." ::= { oaApsConfigGroupEntry 7 } oaApsConfigGroupProtectStatus OBJECT-TYPE SYNTAX INTEGER { inActive(1), active(2), standBy(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the working line-port (wdm-trunk). inActive - Line port is not operational. active - Line port is operational. For BiDirectional mode both Rx & Tx belong to the protected channel, For UniDirectional mode only the Rx or the Tx fiber belongs to the protected channel. standBy - Line port is operational but in standBy mode. For BiDirectional mode both Rx & Tx belong to protected channel, For UniDirectional mode only the Rx or the Tx fiber belongs to the protected channel." ::= { oaApsConfigGroupEntry 8 } oaApsConfigGroupCmdSwitchTrans OBJECT-TYPE SYNTAX ApsSwitchCommand MAX-ACCESS read-write STATUS current DESCRIPTION "Initiate switch command on an APS group." ::= { oaApsConfigGroupEntry 9 } oaApsConfigGroupCmdSwitchRec OBJECT-TYPE SYNTAX ApsSwitchCommand MAX-ACCESS read-only STATUS current DESCRIPTION "Current APS group switch command that was received." ::= { oaApsConfigGroupEntry 10 } oaApsConfigGroupCmdSwitchStatus OBJECT-TYPE SYNTAX ApsSwitchCommand MAX-ACCESS read-only STATUS current DESCRIPTION "Current APS group switch command status." ::= { oaApsConfigGroupEntry 11 } oaApsConfigGroupWorkingLineDefect OBJECT-TYPE SYNTAX BITS { noDefect (0), odu1AIS (1), otu2LOS (2), otu2BDI (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the status of Defects occured in the Working Line Interface. Each Bit in the value represents the corresponding Defect. The whole value represents multiple defects simultaneously. The various Bit positions are: 0 - 'noDefect' 1 - 'odu1AIS' (Alarm Indication Signal) 2 - 'otu2LOS' (Loss Of Signal) 3 - 'otu2BDI' (Backward Defect Indication) In case of 'noDefect' - Bit# 0 will be equal to '1' and all other Bits will be equal to '0'." ::= { oaApsConfigGroupEntry 12 } oaApsConfigGroupProtectLineDefect OBJECT-TYPE SYNTAX BITS { noDefect (0), odu1AIS (1), otu2LOS (2), otu2BDI (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the status of Defects occured in the Protected Line Interface. Each Bit in the value represents the corresponding Defect. The whole value represents multiple defects simultaneously. The various Bit positions are: 0 - 'noDefect' 1 - 'odu1AIS' (Alarm Indication Signal) 2 - 'otu2LOS' (Loss Of Signal) 3 - 'otu2BDI' (Backward Defect Indication) In case of 'noDefect' - Bit# 0 will be equal to '1' and all other Bits will be equal to '0'." ::= { oaApsConfigGroupEntry 13 } ------------------------------------------------------------------------------ -- Conformance Information ------------------------------------------------------------------------------ oaApsMIBCompliances OBJECT IDENTIFIER ::= { oaApsMIBConformance 1 } oaApsMIBGroups OBJECT IDENTIFIER ::= { oaApsMIBConformance 2 } oaApsMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The core compliance statement for all 'oaApsMib' MIB implementations." MODULE -- this module MANDATORY-GROUPS { oaApsMibMandatoryConfigMode, oaApsMibMandatoryConfigGroupMode } ::= { oaApsMIBCompliances 1 } oaApsMibMandatoryConfigMode OBJECT-GROUP OBJECTS { oaApsModeConfigMode, oaApsModeConfigRevert, oaApsModeConfigWaitToRestore, oaApsModeConfigGroups, oaApsModeVersion } STATUS current DESCRIPTION "Mandatory objects for APS global parameters." ::= { oaApsMIBGroups 1 } oaApsMibMandatoryConfigGroupMode OBJECT-GROUP OBJECTS { oaApsConfigGroupName, oaApsConfigGroupPortMembers, oaApsConfigGroupWorkingLinePort, oaApsConfigGroupProtectLinePort, oaApsConfigGroupWorkingStatus, oaApsConfigGroupProtectStatus, oaApsConfigGroupCmdSwitchTrans, oaApsConfigGroupCmdSwitchRec, oaApsConfigGroupCmdSwitchStatus, oaApsConfigGroupWorkingLineDefect, oaApsConfigGroupProtectLineDefect } STATUS current DESCRIPTION "Mandatory objects for APS global parameters." ::= { oaApsMIBGroups 2 } END