-- ************************************************************************** -- -- $Log: mbg-syncbox_n2x-mib.mib $ -- Revision 1.4 2013/11/13 15:53:35Z thomasb -- Revision 1.3 2013/09/20 11:04:02Z thomasb -- Added PTP profile as SNMP object. -- Revision 1.2 2013/09/20 10:17:47Z thomasb -- Added PTP objects -- Revision 1.1 2013/09/05 14:01:54Z thomasb -- Initial revision -- Revision 1.0 2013/09/03 12:05:00 thomasb -- -- ************************************************************************** MBG-SYNCBOX_N2X-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, IpAddress, NOTIFICATION-TYPE FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF DisplayString FROM SNMPv2-TC mbgSnmpRoot FROM MBG-SNMP-ROOT-MIB; mbgSyncboxN2X MODULE-IDENTITY LAST-UPDATED "201309030000Z" ORGANIZATION "www.meinberg.de" CONTACT-INFO "postal: Meinberg Funkuhren Lange Wand 9 31812 Bad Pyrmont Germany email: info@meinberg.de" DESCRIPTION "Meinberg SyncboxN2X SNMP Management Information Base" REVISION "201309030000Z" DESCRIPTION "Rev 0.90 03 September 2013 12:00 UTC Thomas Behn Initial SNMP MIB revision" ::= { mbgSnmpRoot 40 } -- -- Meinberg SyncboxN2X General information -- mbgSyncboxN2XGeneral OBJECT IDENTIFIER ::= { mbgSyncboxN2X 0 } mbgSyncboxN2XSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Number of the SyncboxN2X." ::= { mbgSyncboxN2XGeneral 1 } mbgSyncboxN2XFirmwareRevision OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Firmware Version of the SyncboxN2X." ::= { mbgSyncboxN2XGeneral 2 } mbgSyncboxN2XSystemTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "System time of the SyncboxN2X." ::= { mbgSyncboxN2XGeneral 3 } mbgSyncboxN2XCurrentRefSource OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Currently selected reference source of the SyncboxN2X." ::= { mbgSyncboxN2XGeneral 4 } -- -- Meinberg SyncboxN2X NTP information -- mbgSyncboxN2XNetworkTimeProtocol OBJECT IDENTIFIER ::= { mbgSyncboxN2X 1 } mbgSyncboxN2XNtpSyncStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Synchronization status of NTP." ::= { mbgSyncboxN2XNetworkTimeProtocol 1 } mbgSyncboxN2XNtpSystemPeer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current system peer, chosen from the configured NTP servers." ::= { mbgSyncboxN2XNetworkTimeProtocol 2 } mbgSyncboxN2XNtpStratum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Current stratum value of NTP." ::= { mbgSyncboxN2XNetworkTimeProtocol 3 } mbgSyncboxN2XNtpRefSourceTable OBJECT-TYPE SYNTAX SEQUENCE OF MbgSyncboxN2XNtpRefSourceTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the configured NTP reference sources" ::= { mbgSyncboxN2XNetworkTimeProtocol 4 } mbgSyncboxN2XNtpRefSourceTableEntry OBJECT-TYPE SYNTAX MbgSyncboxN2XNtpRefSourceTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of objects pertaining to an NTP reference source" INDEX { mbgSyncboxN2XNtpRefSourceIndex } ::= { mbgSyncboxN2XNtpRefSourceTable 1 } MbgSyncboxN2XNtpRefSourceTableEntry ::= SEQUENCE { mbgSyncboxN2XNtpRefSourceIndex Unsigned32, mbgSyncboxN2XNtpRefSourceHostname DisplayString, mbgSyncboxN2XNtpRefSourceStratum DisplayString, mbgSyncboxN2XNtpRefSourceReferenceID DisplayString, mbgSyncboxN2XNtpRefSourceReach DisplayString, mbgSyncboxN2XNtpRefSourceCurrPoll DisplayString, mbgSyncboxN2XNtpRefSourceMinPoll DisplayString, mbgSyncboxN2XNtpRefSourceMaxPoll DisplayString, mbgSyncboxN2XNtpRefSourceConfigOptions DisplayString, mbgSyncboxN2XNtpRefSourcePathDelay DisplayString, mbgSyncboxN2XNtpRefSourceOffset DisplayString, mbgSyncboxN2XNtpRefSourceJitter DisplayString } mbgSyncboxN2XNtpRefSourceIndex OBJECT-TYPE SYNTAX Unsigned32(0..6) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the NTP reference source" ::= { mbgSyncboxN2XNtpRefSourceTableEntry 1 } mbgSyncboxN2XNtpRefSourceHostname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Hostname/IP-Address of the NTP reference source" ::= { mbgSyncboxN2XNtpRefSourceTableEntry 2 } mbgSyncboxN2XNtpRefSourceStratum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Stratum value of the NTP reference source" ::= { mbgSyncboxN2XNtpRefSourceTableEntry 3 } mbgSyncboxN2XNtpRefSourceReferenceID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Reference ID of the NTP reference source" ::= { mbgSyncboxN2XNtpRefSourceTableEntry 4 } mbgSyncboxN2XNtpRefSourceReach OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current reach value of the NTP reference source (8-bit shift register)" ::= { mbgSyncboxN2XNtpRefSourceTableEntry 5 } mbgSyncboxN2XNtpRefSourceCurrPoll OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current polling interval of the NTP reference source" ::= { mbgSyncboxN2XNtpRefSourceTableEntry 6 } mbgSyncboxN2XNtpRefSourceMinPoll OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum polling interval of the NTP reference source" ::= { mbgSyncboxN2XNtpRefSourceTableEntry 7 } mbgSyncboxN2XNtpRefSourceMaxPoll OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum polling interval of the NTP reference source" ::= { mbgSyncboxN2XNtpRefSourceTableEntry 8 } mbgSyncboxN2XNtpRefSourceConfigOptions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Configured options for the NTP reference source" ::= { mbgSyncboxN2XNtpRefSourceTableEntry 9 } mbgSyncboxN2XNtpRefSourcePathDelay OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Path Delay to the NTP reference source" ::= { mbgSyncboxN2XNtpRefSourceTableEntry 10 } mbgSyncboxN2XNtpRefSourceOffset OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Offset to the NTP reference source" ::= { mbgSyncboxN2XNtpRefSourceTableEntry 11 } mbgSyncboxN2XNtpRefSourceJitter OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Jitter of the NTP reference source" ::= { mbgSyncboxN2XNtpRefSourceTableEntry 12 } -- -- Meinberg SyncboxN2X PTP information -- mbgSyncboxN2XPrecisionTimeProtocol OBJECT IDENTIFIER ::= { mbgSyncboxN2X 2 } mbgSyncboxN2XPtpProfile OBJECT-TYPE SYNTAX INTEGER { none(0), power(1), telecom(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current PTP profile. 0: None 1: Power Profile 2: Telecom Profile" ::= { mbgSyncboxN2XPrecisionTimeProtocol 1 } mbgSyncboxN2XPtpNwProt OBJECT-TYPE SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2), ieee802_3(3), deviceNet(4), controlNet(5), profiNet(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current PTP network protocol. 0: Unknown 1: IPv4 2: IPv6 3: ieee802.3 4: DeviceNet 5: ControlNet 6: ProfiNet" ::= { mbgSyncboxN2XPrecisionTimeProtocol 2 } mbgSyncboxN2XPtpPortState OBJECT-TYPE SYNTAX INTEGER { uninitialized(0), initializing(1), faulty(2), disabled(3), listening(4), preMaster(5), master(6), passive(7), uncalibrated(8), slave(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current PTP Port State. 0: Uninitialized 1: Initializing 2: Faulty 3: Disabled 4: Listening 5: PreMaster 6: Master 7: Passive 8: Uncalibrated 9: Slave" ::= { mbgSyncboxN2XPrecisionTimeProtocol 3 } mbgSyncboxN2XPtpDelayMechanism OBJECT-TYPE SYNTAX INTEGER { e2e(0), p2p(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current PTP delay mechanism. 0: E2E 1: P2P" ::= { mbgSyncboxN2XPrecisionTimeProtocol 4 } mbgSyncboxN2XPtpDelayRequestInterval OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Current Delay Request interval." ::= { mbgSyncboxN2XPrecisionTimeProtocol 5 } mbgSyncboxN2XPtpTimescale OBJECT-TYPE SYNTAX INTEGER { tai(0), arb(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Currently used timescale. 0: TAI/PTP default 1: Arbitrary" ::= { mbgSyncboxN2XPrecisionTimeProtocol 6 } mbgSyncboxN2XPtpUTCOffset OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current offset to UTC time." ::= { mbgSyncboxN2XPrecisionTimeProtocol 7 } mbgSyncboxN2XPtpLeapSecondAnnounced OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current offset to UTC time." ::= { mbgSyncboxN2XPrecisionTimeProtocol 8 } mbgSyncboxN2XPtpGrandmasterClockID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Clock ID of current PTP Grandmaster." ::= { mbgSyncboxN2XPrecisionTimeProtocol 9 } mbgSyncboxN2XPtpGrandmasterTimesource OBJECT-TYPE SYNTAX INTEGER { atomicClock(16), gps(32), terrestrialRadio(48), ptp(64), ntp(80), handSet(96), other(144), internalOscillator(160) } MAX-ACCESS read-only STATUS current DESCRIPTION "Timesource of the current Grandmaster. 0x10: Atomic Clock 0x20: GPS 0x30: Terrestrial Radio 0x40: PTP 0x50: NTP 0x60: Hand Set 0x90: Other 0xA0: Internal Oscillator" ::= { mbgSyncboxN2XPrecisionTimeProtocol 10 } mbgSyncboxN2XPtpGrandmasterPriority1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Priority 1 of the current Grandmaster." ::= { mbgSyncboxN2XPrecisionTimeProtocol 11 } mbgSyncboxN2XPtpGrandmasterClockClass OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Clock class of the current Grandmaster." ::= { mbgSyncboxN2XPrecisionTimeProtocol 12 } mbgSyncboxN2XPtpGrandmasterClockAccuracy OBJECT-TYPE SYNTAX INTEGER { accurateToWithin25ns(32), accurateToWithin100ns(33), accurateToWithin250ns(34), accurateToWithin1us(35), accurateToWithin2Point5us(36), accurateToWithin10us(37), accurateToWithin25us(38), accurateToWithin100us(39), accurateToWithin250us(40), accurateToWithin1ms(41), accurateToWithin2Point5ms(42), accurateToWithin10ms(43), accurateToWithin25ms(44), accurateToWithin100ms(45), accurateToWithin250ms(46), accurateToWithin1s(47), accurateToWithin10s(48), accurateToGreaterThan10s(49) } MAX-ACCESS read-only STATUS current DESCRIPTION "Clock accuracy of the current Grandmaster. 32: The time is accurate to within 25 ns 33: The time is accurate to within 100 ns 34: The time is accurate to within 250 ns 35: The time is accurate to within 1 µs 36: The time is accurate to within 2.5 µs 37: The time is accurate to within 10 µs 38: The time is accurate to within 25 µs 39: The time is accurate to within 100 µs 40: The time is accurate to within 250 µs 41: The time is accurate to within 1 ms 42: The time is accurate to within 2.5 ms 43: The time is accurate to within 10 ms 44: The time is accurate to within 25 ms 45: The time is accurate to within 100 ms 46: The time is accurate to within 250 ms 47: The time is accurate to within 1 s 48: The time is accurate to within 10 s 49: The time is accurate to >10 s" ::= { mbgSyncboxN2XPrecisionTimeProtocol 13 } mbgSyncboxN2XPtpGrandmasterClockVariance OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Clock variance of the current Grandmaster." ::= { mbgSyncboxN2XPrecisionTimeProtocol 14 } mbgSyncboxN2XPtpGrandmasterPriority2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Priority 2 of the current Grandmaster." ::= { mbgSyncboxN2XPrecisionTimeProtocol 15 } mbgSyncboxN2XPtpOffsetToGrandmaster OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Measured offset to the current Grandmaster." ::= { mbgSyncboxN2XPrecisionTimeProtocol 16 } mbgSyncboxN2XPtpMeanPathDelay OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Measured path delay to the current Grandmaster." ::= { mbgSyncboxN2XPrecisionTimeProtocol 17 } -- -- Meinberg SyncboxN2X Outputs information -- mbgSyncboxN2XOutputs OBJECT IDENTIFIER ::= { mbgSyncboxN2X 3 } mbgSyncboxN2XOutputsTable OBJECT-TYPE SYNTAX SEQUENCE OF MbgSyncboxN2XOutputsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of the configurable signal outputs." ::= { mbgSyncboxN2XOutputs 1 } mbgSyncboxN2XOutputsTableEntry OBJECT-TYPE SYNTAX MbgSyncboxN2XOutputsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of objects pertaining to a signal output." INDEX { mbgSyncboxN2XOutputIndex } ::= { mbgSyncboxN2XOutputsTable 1 } MbgSyncboxN2XOutputsTableEntry ::= SEQUENCE { mbgSyncboxN2XOutputIndex Unsigned32, mbgSyncboxN2XOutputMode INTEGER } mbgSyncboxN2XOutputIndex OBJECT-TYPE SYNTAX Unsigned32(0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the signal output." ::= { mbgSyncboxN2XOutputsTableEntry 1 } mbgSyncboxN2XOutputMode OBJECT-TYPE SYNTAX INTEGER { idle(0), timer(1), singleShot(2), cyclicPulse(3), pulsePerSecond(4), pulsePerMinute(5), pulsePerHour(6), emulatedDCF77(7), positionOK(8), timeSync(9), allSync(10), timecode(11), timestring(12), 10MHz(13), emulatedDCF77M59(14), synthesizer(15), timeSlots(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "Configured mode of the signal output. 00: output is not configured/disabled 01: switch on/off at configured times 02: pulse at specified time 03: pulse in specified interval 04: pulse on second change 05: pulse on minute change 06: pulse on hour change 07: emulated DCF77 signal 08: on if navigation solved 09: on if time synchronized 10: on if positionOK and timeSync 11: IRIG/AFNOR DCLS output 12: serial timestring 13: 10 MHz fixed frequency 14: emulated DCF77 signal with 500 ms pulse in 59th second 15: programmable synthesizer frequency 16: programmable time slots during each minute" ::= { mbgSyncboxN2XOutputsTableEntry 2 } mbgSyncboxN2XSerialString OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Configuration of the serial string output." ::= { mbgSyncboxN2XOutputs 2 } -- -- Conformance Statements -- mbgSyncboxN2XConformance OBJECT IDENTIFIER ::= { mbgSyncboxN2X 10 } mbgSyncboxN2XCompliances OBJECT IDENTIFIER ::= { mbgSyncboxN2XConformance 0 } mbgSyncboxN2XGroups OBJECT IDENTIFIER ::= { mbgSyncboxN2XConformance 1 } mbgSyncboxN2XCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMP entities which implement SyncboxN2X MIB" MODULE -- this module MANDATORY-GROUPS { mbgSyncboxN2XObjectsGroup } ::= { mbgSyncboxN2XCompliances 0 } mbgSyncboxN2XObjectsGroup OBJECT-GROUP OBJECTS { mbgSyncboxN2XSerialNumber, mbgSyncboxN2XFirmwareRevision, mbgSyncboxN2XSystemTime, mbgSyncboxN2XCurrentRefSource, mbgSyncboxN2XNtpSyncStatus, mbgSyncboxN2XNtpSystemPeer, mbgSyncboxN2XNtpStratum, mbgSyncboxN2XNtpRefSourceHostname, mbgSyncboxN2XNtpRefSourceStratum, mbgSyncboxN2XNtpRefSourceReferenceID, mbgSyncboxN2XNtpRefSourceReach, mbgSyncboxN2XNtpRefSourceCurrPoll, mbgSyncboxN2XNtpRefSourceMinPoll, mbgSyncboxN2XNtpRefSourceMaxPoll, mbgSyncboxN2XNtpRefSourceConfigOptions, mbgSyncboxN2XNtpRefSourcePathDelay, mbgSyncboxN2XNtpRefSourceOffset, mbgSyncboxN2XNtpRefSourceJitter, mbgSyncboxN2XPtpProfile, mbgSyncboxN2XPtpNwProt, mbgSyncboxN2XPtpPortState, mbgSyncboxN2XPtpDelayMechanism, mbgSyncboxN2XPtpDelayRequestInterval, mbgSyncboxN2XPtpTimescale, mbgSyncboxN2XPtpUTCOffset, mbgSyncboxN2XPtpLeapSecondAnnounced, mbgSyncboxN2XPtpGrandmasterClockID, mbgSyncboxN2XPtpGrandmasterTimesource, mbgSyncboxN2XPtpGrandmasterPriority1, mbgSyncboxN2XPtpGrandmasterClockClass, mbgSyncboxN2XPtpGrandmasterClockAccuracy, mbgSyncboxN2XPtpGrandmasterClockVariance, mbgSyncboxN2XPtpGrandmasterPriority2, mbgSyncboxN2XPtpOffsetToGrandmaster, mbgSyncboxN2XPtpMeanPathDelay, mbgSyncboxN2XOutputMode, mbgSyncboxN2XSerialString } STATUS current DESCRIPTION "The collection of objects for the SyncboxN2X MIB" ::= { mbgSyncboxN2XGroups 0 } END