KC-300S-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, OBJECT-TYPE, NetworkAddress, IpAddress, Counter, Gauge, TimeTicks FROM RFC1155-SMI; KTI OBJECT IDENTIFIER ::= { enterprises 867 } KC-300S OBJECT IDENTIFIER ::= { KTI 34 } Device_CPU OBJECT IDENTIFIER ::= { KC-300S 1 } Device_Status OBJECT IDENTIFIER ::= { KC-300S 2 } Device_TP_Status OBJECT IDENTIFIER ::= { Device_Status 1 } Device_FX_Status OBJECT IDENTIFIER ::= { Device_Status 2 } Device_Config OBJECT IDENTIFIER ::= { KC-300S 3 } -- object types -- the slot2and3cpumodule group softwareVer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The version of the Convert Center MIB software." ::= { Device_CPU 1 } mibFileVer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The version of the MIB file software." ::= { Device_CPU 2 } Login_Trap_Message1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The version of the MIB file software." ::= { Device_CPU 3 } Login_Trap_Message2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The version of the MIB file software." ::= { Device_CPU 4 } -- the Ports group Device_TP_Config OBJECT-TYPE SYNTAX INTEGER{ Auto_100M_Full(1) Un-auto_100M_Full(2) Un-auto_100M_Half(3) Un-auto_10M_Full(4) Un-auto_10M_Half(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Device_TP_Config." ::= { Device_Config 1 } Trap_Port_Link OBJECT-TYPE SYNTAX INTEGER{ Disabled(0) Enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Trap_Port_Link." ::= { Device_Config 2 } Trap_Login_Failure OBJECT-TYPE SYNTAX INTEGER{ Disabled(0) Enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Trap_Login." ::= { Device_Config 3 } Device_TP_Link_Status OBJECT-TYPE SYNTAX INTEGER{ UP(0), Down(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Device_TP_Link_Status." ::= { Device_TP_Status 1 } Device_TP_LineSpeed_Status OBJECT-TYPE SYNTAX INTEGER{ _100M(0), _10M(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Device_TP_LineSpeed_Status." ::= { Device_TP_Status 2 } Device_TP_Duplex_Status OBJECT-TYPE SYNTAX INTEGER{ Full(0), Half(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Device_TP_Duplex_Status." ::= { Device_TP_Status 3 } Device_TP_FlowControl_Status OBJECT-TYPE SYNTAX INTEGER{ Enable(0), Disable(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Device_TP_FlowControl_Status." ::= { Device_TP_Status 4 } Device_FX_Link_Status OBJECT-TYPE SYNTAX INTEGER{ UP(0), Down(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Device_FX_Link_Status." ::= { Device_FX_Status 1 } Device_FX_LineSpeed_Status OBJECT-TYPE SYNTAX INTEGER{ _100M(0), _10M(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Device_FX_LineSpeed_Status." ::= { Device_FX_Status 2 } Device_FX_Duplex_Status OBJECT-TYPE SYNTAX INTEGER{ Full(0), Half(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Device_FX_Duplex_Status." ::= { Device_FX_Status 3 } Device_FX_FlowControl_Status OBJECT-TYPE SYNTAX INTEGER{ Enable(0), Disable(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Device_FX_FlowControl_Status." ::= { Device_FX_Status 4 } END