KMX-RACK DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString FROM RFC1213-MIB; kentix OBJECT IDENTIFIER ::= { enterprises 37954 } multisensorRack OBJECT IDENTIFIER ::= { kentix 3 } -- Kentix KMS-RACK MODULE-IDENTITY -- LAST-UPDATED "20140611" -- ORGANIZATION -- "Kentix GmbH" -- CONTACT-INFO -- "info@kentix.de" -- DESCRIPTION -- "KMS-RACK MIB module" -- -- REVISION "20140611REV01" -- DESCRIPTION -- "MIB Release version 1.0" -- ::= { multisensorRack } datapoints OBJECT IDENTIFIER ::= { multisensorRack 1 } -- Temperature temperatureEntry OBJECT IDENTIFIER ::= { datapoints 1 } temperatureValue OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature on the Kentix KMS-RACK for that datatpoint (Factor 0.1)" ::= { temperatureEntry 1 } temperatureMin OBJECT-TYPE SYNTAX INTEGER (0..99) ACCESS read-write STATUS mandatory DESCRIPTION "Temperature Min on the Kentix KMS-RACK for that datatpoint" ::= { temperatureEntry 2 } temperatureMax OBJECT-TYPE SYNTAX INTEGER (0..99) ACCESS read-write STATUS mandatory DESCRIPTION "Temperature Max on the Kentix KMS-RACK for that datatpoint" ::= { temperatureEntry 3 } temperatureAlarm OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm on the Kentix KMS-RACK for that datatpoint" ::= { temperatureEntry 4 } temperatureAlarmtext OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Alarmmessage on the Kentix KMS-RACK for that datatpoint" ::= { temperatureEntry 5 } temperatureAlarmArm OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Arm/Disarm TemperatureAlarm on the Kentix KMS-RACK" ::= { temperatureEntry 6 } -- Humidity humidityEntry OBJECT IDENTIFIER ::= { datapoints 2 } humidityValue OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Humidity on the Kentix KMS-RACK for that datatpoint (Factor 0.1)" ::= { humidityEntry 1 } humidityMin OBJECT-TYPE SYNTAX INTEGER (0..99) ACCESS read-write STATUS mandatory DESCRIPTION "Humidity Min on the Kentix KMS-RACK for that datatpoint" ::= { humidityEntry 2 } humidityMax OBJECT-TYPE SYNTAX INTEGER (0..99) ACCESS read-write STATUS mandatory DESCRIPTION "Humidity Max on the Kentix KMS-RACK for that datatpoint" ::= { humidityEntry 3 } humidityAlarm OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm on the Kentix KMS-RACK for that datatpoint" ::= { humidityEntry 4 } humidityAlarmtext OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Alarmmessage on the Kentix KMS-RACK for that datatpoint" ::= { humidityEntry 5 } humidityAlarmArm OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Arm/Disarm HumidityAlarm on the Kentix KMS-RACK" ::= { humidityEntry 6 } -- Dewpoint dewpointEntry OBJECT IDENTIFIER ::= { datapoints 3 } dewpointValue OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Dewpoint on the Kentix KMS-RACK for that datatpoint (Factor 0.1)" ::= { dewpointEntry 1 } dewpointMin OBJECT-TYPE SYNTAX INTEGER (0..99) ACCESS read-write STATUS mandatory DESCRIPTION "Dewpoint Min on the Kentix KMS-RACK for that datatpoint" ::= { dewpointEntry 2 } dewpointAlarm OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm on the Kentix KMS-RACK for that datatpoint" ::= { dewpointEntry 3 } dewpointAlarmtext OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Alarmmessage on the Kentix KMS-RACK for that datatpoint" ::= { dewpointEntry 4 } dewpointAlarmArm OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Arm/Disarm DewpointAlarm on the Kentix KMS-RACK" ::= { dewpointEntry 6 } -- Carbon Monoxide coEntry OBJECT IDENTIFIER ::= { datapoints 4 } coValue OBJECT-TYPE SYNTAX INTEGER (-100..100) ACCESS read-only STATUS mandatory DESCRIPTION "Carbon Monoxide on the Kentix KMS-RACK for that datatpoint" ::= { coEntry 1 } coMax OBJECT-TYPE SYNTAX INTEGER (0..99) ACCESS read-write STATUS mandatory DESCRIPTION "Carbon Monoxide Min on the Kentix KMS-RACK for that datatpoint" ::= { coEntry 2 } coAlarm OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm on the Kentix KMS-RACK for that datatpoint" ::= { coEntry 3 } coAlarmtext OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Alarmmessage on the Kentix KMS-RACK for that datatpoint" ::= { coEntry 4 } coAlarmArm OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Arm/Disarm COAlarm on the Kentix KMS-RACK" ::= { coEntry 6 } -- Motion motionEntry OBJECT IDENTIFIER ::= { datapoints 5 } motionValue OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Motion on the Kentix KMS-RACK for that datatpoint" ::= { motionEntry 1 } motionMax OBJECT-TYPE SYNTAX INTEGER (0..99) ACCESS read-write STATUS mandatory DESCRIPTION "Motion Min on the Kentix KMS-RACK for that datatpoint" ::= { motionEntry 2 } motionAlarm OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm on the Kentix KMS-RACK for that datatpoint" ::= { motionEntry 3 } motionAlarmtext OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Alarmmessage on the Kentix KMS-RACK for that datatpoint" ::= { motionEntry 4 } motionAlarmArm OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Arm/Disarm MotionAlarm on the Kentix KMS-RACK" ::= { motionEntry 6 } -- Digital IN 1 digitalIn1 OBJECT IDENTIFIER ::= { datapoints 6 } digitalIn1Value OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Digital IN 1 on the Kentix KMS-RACK for that datatpoint" ::= { digitalIn1 1 } digitalIn1Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Digital IN 1 on the Kentix KMS-RACK for that datatpoint" ::= { digitalIn1 2 } -- Digital IN 2 digitalIn2 OBJECT IDENTIFIER ::= { datapoints 7 } digitalIn2Value OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Digital IN 2 on the Kentix KMS-RACK for that datatpoint" ::= { digitalIn2 1 } digitalIn2Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Digital IN 2 on the Kentix KMS-RACK for that datatpoint" ::= { digitalIn2 2 } -- Digital OUT 2 digitalOut2 OBJECT IDENTIFIER ::= { datapoints 8 } digitalOut2Value OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Digital OUT 2 on the Kentix KMS-RACK for that datatpoint" ::= { digitalOut2 1 } buzzerTime OBJECT IDENTIFIER ::= { datapoints 9 } buzzerTimeValue OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Buzzer on the Kentix KMS-RACK for that datatpoint" ::= { buzzerTime 1 } -- RelayTime relayTime OBJECT IDENTIFIER ::= { datapoints 10 } relayTimeValue OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Buzzer Time on the Kentix KMS-RACK for that datatpoint" ::= { relayTime 1 } -- Arm-Disarm Motion rearmMotion OBJECT IDENTIFIER ::= { datapoints 11 } rearmMotionValue OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Arm-Disarm Motion on the Kentix KMS-RACK for that datatpoint" ::= { rearmMotion 1 } -- pdu1 pdu1 OBJECT IDENTIFIER ::= { datapoints 12 } pdu1activepowerValue OBJECT-TYPE SYNTAX INTEGER (0..100000) ACCESS read-only STATUS mandatory DESCRIPTION "Active power value of pdu1 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu1 1 } pdu1apparentpowerValue OBJECT-TYPE SYNTAX INTEGER (0..100000) ACCESS read-only STATUS mandatory DESCRIPTION "Apparrnt power value of pdu1 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu1 2 } pdu1energyValue OBJECT-TYPE SYNTAX INTEGER (0..40000000) ACCESS read-only STATUS mandatory DESCRIPTION "Energy value of pdu1 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu1 3 } pdu1energycostsValue OBJECT-TYPE SYNTAX INTEGER (0..40000000) ACCESS read-only STATUS mandatory DESCRIPTION "Energy costs value of pdu1 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu1 4 } pdu1currentValue OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Current value of pdu1 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu1 5 } pdu1voltageValue OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "Voltage value of pdu1 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu1 6 } pdu1powerfactorValue OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Power factor of pdu1 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu1 7 } pdu1frequencyValue OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Frequency of pdu1 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu1 8 } pdu1VoltageFlicker OBJECT IDENTIFIER ::= { pdu1 9 } pdu1VoltageFlickerValue OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Flicker (low voltage) value of pdu1 on the Kentix KMS-RACK." ::= { pdu1VoltageFlicker 1 } pdu1VoltageFlickerTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Last Flicker (low voltage) time of pdu1 on the Kentix KMS-RACK." ::= { pdu1VoltageFlicker 2 } pdu1VoltageFlickerState OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarmstate Flicker (low voltage) of pdu1 on the Kentix KMS-RACK." ::= { pdu1VoltageFlicker 3 } pdu1VoltageSwell OBJECT IDENTIFIER ::= { pdu1 10 } pdu1VoltageSwellValue OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Voltage swell value of pdu1 on the Kentix KMS-RACK." ::= { pdu1VoltageSwell 1 } pdu1VoltageSwellTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Last voltage swell time of pdu1 on the Kentix KMS-RACK." ::= { pdu1VoltageSwell 2 } pdu1VoltageSwellState OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarmstate voltage swell of pdu1 on the Kentix KMS-RACK." ::= { pdu1VoltageSwell 3 } pdu1VoltagePeak OBJECT IDENTIFIER ::= { pdu1 11 } pdu1VoltagePeakValue OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "VoltagePeakvoltage value of pdu1 on the Kentix KMS-RACK." ::= { pdu1VoltagePeak 1 } pdu1VoltagePeakTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Last peakvoltage time of pdu1 on the Kentix KMS-RACK." ::= { pdu1VoltagePeak 2 } pdu1VoltagePeakState OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarmstate peakvoltage of pdu1 on the Kentix KMS-RACK." ::= { pdu1VoltagePeak 3 } -- pdu2 pdu2 OBJECT IDENTIFIER ::= { datapoints 13 } pdu2activepowerValue OBJECT-TYPE SYNTAX INTEGER (0..100000) ACCESS read-only STATUS mandatory DESCRIPTION "Active power value of pdu2 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu2 1 } pdu2apparentpowerValue OBJECT-TYPE SYNTAX INTEGER (0..100000) ACCESS read-only STATUS mandatory DESCRIPTION "Apparrnt power value of pdu2 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu2 2 } pdu2energyValue OBJECT-TYPE SYNTAX INTEGER (0..40000000) ACCESS read-only STATUS mandatory DESCRIPTION "Energy value of pdu2 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu2 3 } pdu2energycostsValue OBJECT-TYPE SYNTAX INTEGER (0..40000000) ACCESS read-only STATUS mandatory DESCRIPTION "Energy costs value of pdu2 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu2 4 } pdu2currentValue OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Current value of pdu2 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu2 5 } pdu2voltageValue OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "Voltage value of pdu2 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu2 6 } pdu2powerfactorValue OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Power factor of pdu2 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu2 7 } pdu2frequencyValue OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Frequency of pdu2 on the Kentix KMS-RACK (Factor 0.1)" ::= { pdu2 8 } pdu2VoltageFlicker OBJECT IDENTIFIER ::= { pdu2 9 } pdu2VoltageFlickerValue OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Flicker (low voltage) value of pdu2 on the Kentix KMS-RACK." ::= { pdu2VoltageFlicker 1 } pdu2VoltageFlickerTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Last Flicker (low voltage) time of pdu2 on the Kentix KMS-RACK." ::= { pdu2VoltageFlicker 2 } pdu2VoltageFlickerState OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarmstate Flicker (low voltage) of pdu2 on the Kentix KMS-RACK." ::= { pdu2VoltageFlicker 3 } pdu2VoltageSwell OBJECT IDENTIFIER ::= { pdu2 10 } pdu2VoltageSwellValue OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Voltage swell value of pdu2 on the Kentix KMS-RACK." ::= { pdu2VoltageSwell 1 } pdu2VoltageSwellTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Last voltage swell time of pdu2 on the Kentix KMS-RACK." ::= { pdu2VoltageSwell 2 } pdu2VoltageSwellState OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarmstate voltage swell of pdu2 on the Kentix KMS-RACK." ::= { pdu2VoltageSwell 3 } pdu2VoltagePeak OBJECT IDENTIFIER ::= { pdu2 11 } pdu2VoltagePeakValue OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Peakvoltage value of pdu2 on the Kentix KMS-RACK." ::= { pdu2VoltagePeak 1 } pdu2VoltagePeakTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Last peakvoltage time of pdu2 on the Kentix KMS-RACK." ::= { pdu2VoltagePeak 2 } pdu2VoltagePeakState OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarmstate peakvoltage of pdu2 on the Kentix KMS-RACK." ::= { pdu2VoltagePeak 3 } -- pdu1 pdusum OBJECT IDENTIFIER ::= { datapoints 14 } pdusumactivepowerValue OBJECT-TYPE SYNTAX INTEGER (0..100000) ACCESS read-only STATUS mandatory DESCRIPTION "Active power value of all pdus the Kentix KMS-RACK (Factor 0.1)" ::= { pdusum 1 } pdusumapparentpowerValue OBJECT-TYPE SYNTAX INTEGER (0..100000) ACCESS read-only STATUS mandatory DESCRIPTION "Apparrnt power value of all pdus the Kentix KMS-RACK (Factor 0.1)" ::= { pdusum 2 } pdusumenergyValue OBJECT-TYPE SYNTAX INTEGER (0..40000000) ACCESS read-only STATUS mandatory DESCRIPTION "Energy value of all pdus the Kentix KMS-RACK (Factor 0.1)" ::= { pdusum 3 } pdusumenergycostsValue OBJECT-TYPE SYNTAX INTEGER (0..40000000) ACCESS read-only STATUS mandatory DESCRIPTION "Energy costs value of all pdus the Kentix KMS-RACK (Factor 0.1)" ::= { pdusum 4 } pdusumcurrentValue OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Current value of all pdus the Kentix KMS-RACK (Factor 0.1)" ::= { pdusum 5 } pdusumvoltageValue OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "Voltage value of all pdus the Kentix KMS-RACK (Factor 0.1)" ::= { pdusum 6 } pdusumpowerfactorValue OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Power factor of all pdus the Kentix KMS-RACK (Factor 0.1)" ::= { pdusum 7 } pdusumfrequencyValue OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Frequency of all pdus the Kentix KMS-RACK (Factor 0.1)" ::= { pdusum 8 } alarmText OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Text send to the Manager" ::= { multisensorRack 2 } wrongLogin TRAP-TYPE ENTERPRISE kentix DESCRIPTION "wrong login of a user" ::= 1 login TRAP-TYPE ENTERPRISE kentix DESCRIPTION "login of user" ::= 2 alarm TRAP-TYPE ENTERPRISE kentix VARIABLES { alarmText } DESCRIPTION "SNMP Trap for each multisensor alarm" ::= 3 END