-- -- ISKRATEL-IPMI-MIB.mib -- MIB generated by MG-SOFT Visual MIB Builder Version 7.0 Build 240 -- Wednesday, March 28, 2012 at 12:22:19 -- ISKRATEL-IPMI-MIB DEFINITIONS ::= BEGIN IMPORTS msanAdditionalConf FROM ISKRATEL-MSAN-MIB DisplayString FROM RFC1213-MIB Integer32, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI; -- 1.3.6.1.4.1.1332.1.1.5.3.33 msanShMC MODULE-IDENTITY LAST-UPDATED "201203280944Z" -- March 28, 2012 at 09:44 GMT ORGANIZATION "Iskratel" CONTACT-INFO "Contact-info." DESCRIPTION "Description." ::= { msanAdditionalConf 33 } -- -- Node definitions -- -- 1.3.6.1.4.1.1332.1.1.5.3.33.1 msanShMCImpControllerVariablesTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCImpControllerVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Imp Controller report" ::= { msanShMC 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.1.1 msanShMCImpControllerVariablesEntry OBJECT-TYPE SYNTAX MsanShMCImpControllerVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An IPM Controller entry" INDEX { msanShMCImpControllerIndex } ::= { msanShMCImpControllerVariablesTable 1 } MsanShMCImpControllerVariablesEntry ::= SEQUENCE { msanShMCImpControllerIndex INTEGER, msanShMCImpControllerSdrVersion INTEGER, msanShMCImpControllerPicmgVersion INTEGER, msanShMCImpControllerSlaveAddress INTEGER, msanShMCImpControllerChannelNumber INTEGER, msanShMCImpControllerPowerStateNotification INTEGER, msanShMCImpControllerGlobalInitialisation INTEGER, msanShMCImpControllerCapabilities INTEGER, msanShMCImpControllerIdString DisplayString, msanShMCImpControllerMaximumFru INTEGER, msanShMCImpControllerOwnFruId INTEGER } -- 1.3.6.1.4.1.1332.1.1.5.3.33.1.1.1 msanShMCImpControllerIndex OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Table entry index, equal to " ::= { msanShMCImpControllerVariablesEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.1.1.2 msanShMCImpControllerSdrVersion OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "SDR Version of the Management Controller Device Locator Record for this controller" ::= { msanShMCImpControllerVariablesEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.1.1.3 msanShMCImpControllerPicmgVersion OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "PICMG Extension Version as reported by controller in a Get PICMG Properties replay" ::= { msanShMCImpControllerVariablesEntry 3 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.1.1.4 msanShMCImpControllerSlaveAddress OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Device Slave Address as defined in the Management Controller Device Locator Record for this controller" ::= { msanShMCImpControllerVariablesEntry 4 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.1.1.5 msanShMCImpControllerChannelNumber OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Channel Number as defined in the Management Controller Device Locator Record for this controller" ::= { msanShMCImpControllerVariablesEntry 5 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.1.1.6 msanShMCImpControllerPowerStateNotification OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Power State Notification as defined in the Management Controller Device Locator Record for this controller" ::= { msanShMCImpControllerVariablesEntry 6 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.1.1.7 msanShMCImpControllerGlobalInitialisation OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Global Initialisation as defined in the Management Controller Device Locator Record for this controller" ::= { msanShMCImpControllerVariablesEntry 7 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.1.1.8 msanShMCImpControllerCapabilities OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Device Capabilities as defined in the Management Controller Device Locator Record for this controller" ::= { msanShMCImpControllerVariablesEntry 8 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.1.1.9 msanShMCImpControllerIdString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Device ID String as defined in the Management Controller Device Locator Record for this controller" ::= { msanShMCImpControllerVariablesEntry 9 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.1.1.10 msanShMCImpControllerMaximumFru OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Max FRU Device ID as reported by controller in a Get PICMG Properties replay" ::= { msanShMCImpControllerVariablesEntry 10 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.1.1.11 msanShMCImpControllerOwnFruId OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "FRU Device ID from IPM Controller as reported by controller in a Get PICMG Properties replay" ::= { msanShMCImpControllerVariablesEntry 11 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.2 msanShMCFruDeviceVariablesTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCFruDeviceVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A FRU Device report" ::= { msanShMC 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.2.1 msanShMCFruDeviceVariablesEntry OBJECT-TYPE SYNTAX MsanShMCFruDeviceVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An IPM Controller entry" INDEX { msanShMCFruDeviceIndex } ::= { msanShMCFruDeviceVariablesTable 1 } MsanShMCFruDeviceVariablesEntry ::= SEQUENCE { msanShMCFruDeviceIndex INTEGER, msanShMCFruDeviceSdrVersion INTEGER, msanShMCFruDeviceSlaveAddress INTEGER, msanShMCFruDeviceSFruDeviceId INTEGER, msanShMCFruDeviceChannelNumber INTEGER, msanShMCFruDeviceDeviceType INTEGER, msanShMCFruDeviceDeviceTypeModifier INTEGER, msanShMCFruDeviceFruEntityId INTEGER, msanShMCFruDeviceFruEntityInstance INTEGER, msanShMCFruDeviceIdString DisplayString, msanShMCFruDeviceHotSwapState INTEGER, msanShMCFruDeviceActivated INTEGER } -- 1.3.6.1.4.1.1332.1.1.5.3.33.2.1.1 msanShMCFruDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..-1) MAX-ACCESS read-only STATUS current DESCRIPTION "Table entry index, equal to << 16 | " ::= { msanShMCFruDeviceVariablesEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.2.1.2 msanShMCFruDeviceSdrVersion OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "SDR Version of the Management Controller Device Locator Record for this FRU" ::= { msanShMCFruDeviceVariablesEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.2.1.3 msanShMCFruDeviceSlaveAddress OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Device Slave Address as defined in the Management Controller Device Locator Record for this FRU" ::= { msanShMCFruDeviceVariablesEntry 3 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.2.1.4 msanShMCFruDeviceSFruDeviceId OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "FRU Device as defined in the Management Controller Device Locator Record for this FRU" ::= { msanShMCFruDeviceVariablesEntry 4 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.2.1.5 msanShMCFruDeviceChannelNumber OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Channel Number as defined in the Management Controller Device Locator Record for this FRU" ::= { msanShMCFruDeviceVariablesEntry 5 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.2.1.6 msanShMCFruDeviceDeviceType OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "For FRUs with FRU Device ID different from zero: Device Type as defined in the FRU Device Locator Record for this FRU. Since the Management Controller Device Locator Record doesn't provide the Device Type information, for Management Controller devices (FRU #0), this field is set to FRU Inventory Device (10h)." ::= { msanShMCFruDeviceVariablesEntry 6 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.2.1.7 msanShMCFruDeviceDeviceTypeModifier OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "For FRUs with FRU Device ID different from zero: Device Type as defined in the FRU Device Locator Record for this FRU. Since the Management Controller Device Locator Record doesn't provide the Device Type information, for Management Controller devices (FRU #0), this field is set to Unspecified (FFh)." ::= { msanShMCFruDeviceVariablesEntry 7 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.2.1.8 msanShMCFruDeviceFruEntityId OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "(FRU) entity ID as defined in the Management Controller Device Locator Record for this FRU" ::= { msanShMCFruDeviceVariablesEntry 8 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.2.1.9 msanShMCFruDeviceFruEntityInstance OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Channel Number as defined in the Management Controller Device Locator Record for this controller" ::= { msanShMCFruDeviceVariablesEntry 9 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.2.1.10 msanShMCFruDeviceIdString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Device ID String as defined in the Management Controller Device Locator Record for this FRU" ::= { msanShMCFruDeviceVariablesEntry 10 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.2.1.11 msanShMCFruDeviceHotSwapState OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Current PICMG 3.0 FRU state (M0..M7) for this FRU. If this variable is equal to n, that means that the FRU is in stat Mn" ::= { msanShMCFruDeviceVariablesEntry 11 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.2.1.12 msanShMCFruDeviceActivated OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "When reading: 1 means that the FRU device is active (that is, in state M4), 0 is return otherwise. When writing: writing 1 to this variable triggers sending the Set FRU Activation (Activate FRU) command to this FRU, if the FRU is in state M2 or M5, and sending Set FRU Activation policy (Clear Locked) command if the FRU is in state M1. writin 0 to this variable triggers sending the Set FRU Activation (Deactivate FRU) command to this FRU, if the FRU is in state M2, M3, M4 or M5, and sending Set FRU Activation policy (Set Locked) command if the FRU is in state M1 or M6" ::= { msanShMCFruDeviceVariablesEntry 12 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3 msanShMCSensorVariablesTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCSensorVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Sensor report" ::= { msanShMC 3 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1 msanShMCSensorVariablesEntry OBJECT-TYPE SYNTAX MsanShMCSensorVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An IPM Controller entry" INDEX { msanShMCSensorIndex } ::= { msanShMCSensorVariablesTable 1 } MsanShMCSensorVariablesEntry ::= SEQUENCE { msanShMCSensorIndex INTEGER, msanShMCSensorSdrVersion INTEGER, msanShMCSensorRecordType INTEGER, msanShMCSensorOwnerId INTEGER, msanShMCSensorOwnerLun INTEGER, msanShMCSensorNumber INTEGER, msanShMCSensorEntityInstance INTEGER, msanShMCSensorEntityId INTEGER, msanShMCSensorInitialisation INTEGER, msanShMCSensorCapabilities INTEGER, msanShMCSensorType INTEGER, msanShMCSensorEvent INTEGER, msanShMCSensorAssertionEventMask INTEGER, msanShMCSensorDeassertionEventMask INTEGER, msanShMCSensorMask INTEGER, msanShMCSensorUnit1 INTEGER, msanShMCSensorUnit2 INTEGER, msanShMCSensorUnit3 INTEGER, msanShMCSensorLinearization INTEGER, msanShMCSensorM INTEGER, msanShMCSensorTolerance INTEGER, msanShMCSensorB INTEGER, msanShMCSensorAccuracy INTEGER, msanShMCSensorAccuracyExp INTEGER, msanShMCSensorRexp INTEGER, msanShMCSensorBexp INTEGER, msanShMCSensorCharacteristicFlags INTEGER, msanShMCSensorReading INTEGER, msanShMCSensorProcessedReading DisplayString, msanShMCSensorNominalReading INTEGER, msanShMCSensorNormalMaximum INTEGER, msanShMCSensorNormalMinimum INTEGER, msanShMCSensorMaximumReading INTEGER, msanShMCSensorMinimumReading INTEGER, msanShMCSensorUpperNonRecoverableThr INTEGER, msanShMCSensorUpperCriticalThr INTEGER, msanShMCSensorUpperNonCriticalThr INTEGER, msanShMCSensorLowerNonRecoverableThr INTEGER, msanShMCSensorLowerCriticalThr INTEGER, msanShMCSensorLowerNonCriticalThr INTEGER, msanShMCSensorPositiveGoingThrHysteresis INTEGER, msanShMCSensorNegativeGoingThrHysteresis INTEGER, msanShMCSensorIdString DisplayString, msanShMCSensorEntireSensorData OCTET STRING } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.1 msanShMCSensorIndex OBJECT-TYPE SYNTAX INTEGER (0..-1) MAX-ACCESS read-only STATUS current DESCRIPTION "Table entry index, equal to << 16 | " ::= { msanShMCSensorVariablesEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.2 msanShMCSensorSdrVersion OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "SDR Version of the Sensor Record" ::= { msanShMCSensorVariablesEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.3 msanShMCSensorRecordType OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Record Type of Sensor Record: 01h - for Full Sensor Records" ::= { msanShMCSensorVariablesEntry 3 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.4 msanShMCSensorOwnerId OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Owner ID as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 4 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.5 msanShMCSensorOwnerLun OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Owner LUN as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 5 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.6 msanShMCSensorNumber OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Number as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 6 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.7 msanShMCSensorEntityInstance OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Entity Instance as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 7 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.8 msanShMCSensorEntityId OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Entity ID as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 8 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.9 msanShMCSensorInitialisation OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Initialisation as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 9 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.10 msanShMCSensorCapabilities OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Capabilities as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 10 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.11 msanShMCSensorType OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Type as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 11 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.12 msanShMCSensorEvent OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Event/reading Type Code as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 12 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.13 msanShMCSensorAssertionEventMask OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Assertion Event Mask / Lower Treshold Reading Mask as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 13 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.14 msanShMCSensorDeassertionEventMask OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Deassertion Event Mask / Upper Treshold Reading Mask as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 14 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.15 msanShMCSensorMask OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Discrete Reading Mask / Settable Treshold Mask as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 15 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.16 msanShMCSensorUnit1 OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Units 1 as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 16 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.17 msanShMCSensorUnit2 OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Units 2 as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 17 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.18 msanShMCSensorUnit3 OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Units 3 as defined in the Sensor Record" ::= { msanShMCSensorVariablesEntry 18 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.19 msanShMCSensorLinearization OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Linearization as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 19 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.20 msanShMCSensorM OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "M sensor reading conversion parameter as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 20 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.21 msanShMCSensorTolerance OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Tolerance sensor reading conversion parameter as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 21 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.22 msanShMCSensorB OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "B sensor reading conversion parameter as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 22 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.23 msanShMCSensorAccuracy OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Accuracy sensor reading conversion parameter as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 23 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.24 msanShMCSensorAccuracyExp OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Accuracy exp sensor reading conversion parameter as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 24 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.25 msanShMCSensorRexp OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "R exp sensor reading conversion parameter as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 25 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.26 msanShMCSensorBexp OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "B exp sensor reading conversion parameter as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 26 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.27 msanShMCSensorCharacteristicFlags OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Analog characteristic flags as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 27 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.28 msanShMCSensorReading OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Current sensor reading in raw form." ::= { msanShMCSensorVariablesEntry 28 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.29 msanShMCSensorProcessedReading OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Current sensor reading processed according to reading conversion formula for this sensor" ::= { msanShMCSensorVariablesEntry 29 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.30 msanShMCSensorNominalReading OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Nominal Reading as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 30 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.31 msanShMCSensorNormalMaximum OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Normal Maximum as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 31 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.32 msanShMCSensorNormalMinimum OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Normal Minimum as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 32 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.33 msanShMCSensorMaximumReading OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Maximum Reading as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 33 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.34 msanShMCSensorMinimumReading OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor Minimum Reading as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 34 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.35 msanShMCSensorUpperNonRecoverableThr OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Upper non-recoverable Threshold as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 35 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.36 msanShMCSensorUpperCriticalThr OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Upper critical Threshold as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 36 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.37 msanShMCSensorUpperNonCriticalThr OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Upper non-critical Threshold as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 37 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.38 msanShMCSensorLowerNonRecoverableThr OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Lower non-recoverable Threshold as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 38 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.39 msanShMCSensorLowerCriticalThr OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Lower critical Threshold as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 39 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.40 msanShMCSensorLowerNonCriticalThr OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Lower non-critical Threshold as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 40 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.41 msanShMCSensorPositiveGoingThrHysteresis OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Positive-going Threshold Hysteresis as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 41 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.42 msanShMCSensorNegativeGoingThrHysteresis OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Negative-going Threshold Hysteresis as defined in the Sensor Record. Valid only for full Sensor Records." ::= { msanShMCSensorVariablesEntry 42 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.43 msanShMCSensorIdString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Device ID String as defined in the Sensor Record." ::= { msanShMCSensorVariablesEntry 43 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.3.1.44 msanShMCSensorEntireSensorData OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Device ID String as defined in the Sensor Record." ::= { msanShMCSensorVariablesEntry 44 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.4 msanShMCBoardsTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCBoardsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of boards" ::= { msanShMC 4 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.4.1 msanShMCBoardsEntry OBJECT-TYPE SYNTAX MsanShMCBoardsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An IPM Controller entry" INDEX { msanShMCBoardsIndex } ::= { msanShMCBoardsTable 1 } MsanShMCBoardsEntry ::= SEQUENCE { msanShMCBoardsIndex INTEGER, msanShMCBoardsBoardBasicPresent INTEGER, msanShMCBoardsBoardBasicHealthy INTEGER, msanShMCBoardsBoardBasicReset INTEGER, msanShMCBoardsBoardBasicSlaveAddress INTEGER, msanShMCBoardsBoardBasicFruDeviceId INTEGER } -- 1.3.6.1.4.1.1332.1.1.5.3.33.4.1.1 msanShMCBoardsIndex OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Table index equal to " ::= { msanShMCBoardsEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.4.1.2 msanShMCBoardsBoardBasicPresent OBJECT-TYPE SYNTAX INTEGER { absent(0), present(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "0 - Board is absent 1 - Board is present" ::= { msanShMCBoardsEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.4.1.3 msanShMCBoardsBoardBasicHealthy OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Causes the BMC to return a high level version of the system health status in integer. The BMC returns an integer with the following values: 0 - off 1 - on" ::= { msanShMCBoardsEntry 3 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.4.1.4 msanShMCBoardsBoardBasicReset OBJECT-TYPE SYNTAX INTEGER { none(0), cold(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "on read: 1 - board is in reset state 0 - otherwise on write: 0 - do nothing 1 - perform COLD reset" ::= { msanShMCBoardsEntry 4 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.4.1.5 msanShMCBoardsBoardBasicSlaveAddress OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The on board IPMI controller 7-bit I2C addresses for IPMB messages" ::= { msanShMCBoardsEntry 5 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.4.1.7 msanShMCBoardsBoardBasicFruDeviceId OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "FRU Device ID field is used to identify individual FRU devices on the given LUN in the management controller. Up to 255 FRU devices can be located on a given LUN. FRU Device ID #00 at LUN 00b is predefined as being the FRU Device for the FRU that the management controller is located on. Since there are four possible LUNs for a management controller, this means up to 255*4 FRU devices can be supported behind a single management controller using this mechanism. The Read/Write FRU Device commands provide an abstracted interface that hides the technology used to implement the FRU device from system software." ::= { msanShMCBoardsEntry 7 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.5 msanShMCSelTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCSelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Sel" ::= { msanShMC 5 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.5.1 msanShMCSelEntry OBJECT-TYPE SYNTAX MsanShMCSelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An System Event Log Variables entry" INDEX { msanShMCSelIndex } ::= { msanShMCSelTable 1 } MsanShMCSelEntry ::= SEQUENCE { msanShMCSelIndex INTEGER, msanShMCSelcontents OCTET STRING } -- 1.3.6.1.4.1.1332.1.1.5.3.33.5.1.1 msanShMCSelIndex OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Table entry index, equal to " ::= { msanShMCSelEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.5.1.2 msanShMCSelcontents OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Contents of the SEL entry" ::= { msanShMCSelEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.6 msanShMCShelfTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCShelfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Shelf" ::= { msanShMC 6 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.6.1 msanShMCShelfEntry OBJECT-TYPE SYNTAX MsanShMCShelfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An System Event Log Variables entry" INDEX { msanShMCShelfIndex } ::= { msanShMCShelfTable 1 } MsanShMCShelfEntry ::= SEQUENCE { msanShMCShelfIndex INTEGER, msanShMCShelfHealthy INTEGER } -- 1.3.6.1.4.1.1332.1.1.5.3.33.6.1.1 msanShMCShelfIndex OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Table entry index, equal to " ::= { msanShMCShelfEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.6.1.2 msanShMCShelfHealthy OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "1 - if the shelf doesn't have unhealthy components, 0 - if there exist unhelthy components in the shelf" ::= { msanShMCShelfEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.8 msanShMCPefConfiguration OBJECT IDENTIFIER ::= { msanShMC 8 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.8.1 msanShMCPefConfigurationSetInProgress OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set in progrese parameter" ::= { msanShMCPefConfiguration 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.8.2 msanShMCPefConfigurationControl OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "PEF Control parameter" ::= { msanShMCPefConfiguration 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.8.3 msanShMCPefConfigurationActionGlobalControl OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "PEF Action global control parameter" ::= { msanShMCPefConfiguration 3 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.8.4 msanShMCPefConfigurationStartupDelay OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "PEF Startup Delay parameter" ::= { msanShMCPefConfiguration 4 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.8.5 msanShMCPefConfigurationAlertStartupDelay OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "PEF Alert Startup Delay parameter" ::= { msanShMCPefConfiguration 5 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.8.6 msanShMCPefConfigurationNumberOfEventFilters OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Event Filters parameter" ::= { msanShMCPefConfiguration 6 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.8.7 msanShMCPefConfigurationNumberOfAlertPoliciEntries OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Alert Polici Entries parameter" ::= { msanShMCPefConfiguration 7 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.8.8 msanShMCPefConfigurationSystemGuid OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "System GUID parameter, excluding the 'Used to fill in the GUID field in a PET Trap' byte" ::= { msanShMCPefConfiguration 8 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.8.9 msanShMCPefConfigurationNumberOfAlertStrings OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Alert Strings parameter" ::= { msanShMCPefConfiguration 9 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.14 msanShMCPefConfigurationEventFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCPefConfigurationEventFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of PefConfigurationEventFilter" ::= { msanShMC 14 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.14.1 msanShMCPefConfigurationEventFilterEntry OBJECT-TYPE SYNTAX MsanShMCPefConfigurationEventFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An System Event Log Variables entry" INDEX { msanShMCPefConfigurationEventFilterIndex } ::= { msanShMCPefConfigurationEventFilterTable 1 } MsanShMCPefConfigurationEventFilterEntry ::= SEQUENCE { msanShMCPefConfigurationEventFilterIndex INTEGER, msanShMCPefConfigurationEventFilterData OCTET STRING } -- 1.3.6.1.4.1.1332.1.1.5.3.33.14.1.1 msanShMCPefConfigurationEventFilterIndex OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Table entry index, equal to " ::= { msanShMCPefConfigurationEventFilterEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.14.1.2 msanShMCPefConfigurationEventFilterData OBJECT-TYPE SYNTAX OCTET STRING (SIZE (20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Event Filter Table entry data, excluding the Set Selector byte" ::= { msanShMCPefConfigurationEventFilterEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.19 msanShMCPefConfigurationAlertStringTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCPefConfigurationAlertStringEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of PEF Configuration Alert String" ::= { msanShMC 19 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.19.1 msanShMCPefConfigurationAlertStringEntry OBJECT-TYPE SYNTAX MsanShMCPefConfigurationAlertStringEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An System Event Log Variables entry" INDEX { msanShMCPefConfigurationAlertStringIndex } ::= { msanShMCPefConfigurationAlertStringTable 1 } MsanShMCPefConfigurationAlertStringEntry ::= SEQUENCE { msanShMCPefConfigurationAlertStringIndex INTEGER, msanShMCPefConfigurationAlertStringKey OCTET STRING, msanShMCPefConfigurationAlertString DisplayString } -- 1.3.6.1.4.1.1332.1.1.5.3.33.19.1.1 msanShMCPefConfigurationAlertStringIndex OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Table entry index, equal to " ::= { msanShMCPefConfigurationAlertStringEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.19.1.2 msanShMCPefConfigurationAlertStringKey OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) MAX-ACCESS read-only STATUS current DESCRIPTION "Alert String Keys entry data, excluding the Set Selector byte" ::= { msanShMCPefConfigurationAlertStringEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.19.1.3 msanShMCPefConfigurationAlertString OBJECT-TYPE SYNTAX DisplayString (SIZE (255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Alert Strings entry data, excluding the Set Selector byte" ::= { msanShMCPefConfigurationAlertStringEntry 3 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.20 msanShMCFruInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCFruInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Fru Infornations" ::= { msanShMC 20 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.20.1 msanShMCFruInfoEntry OBJECT-TYPE SYNTAX MsanShMCFruInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An FRU information" INDEX { msanShMCFruInfoIndex } ::= { msanShMCFruInfoTable 1 } MsanShMCFruInfoEntry ::= SEQUENCE { msanShMCFruInfoIndex INTEGER, msanShMCFruInfoData OCTET STRING, msanShMCFruInfoDataWo OCTET STRING } -- 1.3.6.1.4.1.1332.1.1.5.3.33.20.1.1 msanShMCFruInfoIndex OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Index = ( << 24) | ( << 16) | " ::= { msanShMCFruInfoEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.20.1.2 msanShMCFruInfoData OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "A block of data" ::= { msanShMCFruInfoEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.20.1.3 msanShMCFruInfoDataWo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Write any number of bytes up to 32. Due to limitations in the current version of the SNMP agent, is interpreted as a byte offest" ::= { msanShMCFruInfoEntry 3 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32 msanShMCBoardVariablesTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCBoardVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of boards" ::= { msanShMC 32 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1 msanShMCBoardVariablesEntry OBJECT-TYPE SYNTAX MsanShMCBoardVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An IPM Controller entry" INDEX { msanShMCBoardVariablesBoardBasicSlotNumber } ::= { msanShMCBoardVariablesTable 1 } MsanShMCBoardVariablesEntry ::= SEQUENCE { msanShMCBoardVariablesBoardBasicSlotNumber INTEGER, msanShMCBoardVariablesBoardBasicPresent INTEGER, msanShMCBoardVariablesBoardBasicHealthy INTEGER, msanShMCBoardVariablesBoardBasicReset INTEGER, msanShMCBoardVariablesBoardBasicPowered INTEGER, msanShMCBoardVariablesBoardBasicSlaveAddress INTEGER, msanShMCBoardVariablesBoardBasicFruDeviceId INTEGER, msanShMCBoardVariablesBoardBasicFruinfoProductAreaPresent INTEGER, msanShMCBoardVariablesBoardBasicProductManufacturer DisplayString, msanShMCBoardVariablesBoardBasicProductName DisplayString, msanShMCBoardVariablesBoardBasicProductPartModelNumber DisplayString, msanShMCBoardVariablesBoardBasicProductVersionNumber DisplayString, msanShMCBoardVariablesBoardBasicProductSerialNumber DisplayString, msanShMCBoardVariablesBoardBasicBoardAreaPresent INTEGER, msanShMCBoardVariablesBoardBasicBoardManufacturer DisplayString, msanShMCBoardVariablesBoardBasicBoardProductName DisplayString, msanShMCBoardVariablesBoardBasicBoardSerialNumber DisplayString, msanShMCBoardVariablesBoardBasicBoardPartNumber DisplayString, msanShMCBoardVariablesBoardBasicBoardManufactureTime Integer32, msanShMCBoardVariablesSelectivePowerOffSwitchOffType INTEGER } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.1 msanShMCBoardVariablesBoardBasicSlotNumber OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Table index equal to " ::= { msanShMCBoardVariablesEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.2 msanShMCBoardVariablesBoardBasicPresent OBJECT-TYPE SYNTAX INTEGER { absent(0), present(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "0 - Board is absent 1 - Board is present" ::= { msanShMCBoardVariablesEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.3 msanShMCBoardVariablesBoardBasicHealthy OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Causes the BMC to return a high level version of the system health status in integer. The BMC returns an integer with the following values: 0 - off 1 - on" ::= { msanShMCBoardVariablesEntry 3 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.4 msanShMCBoardVariablesBoardBasicReset OBJECT-TYPE SYNTAX INTEGER { none(0), cold(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "on read: 1 - board is in reset state 0 - otherwise on write: 0 - do nothing 1 - perform COLD reset" ::= { msanShMCBoardVariablesEntry 4 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.5 msanShMCBoardVariablesBoardBasicPowered OBJECT-TYPE SYNTAX INTEGER { none(0), powered(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "on read: 1 - board is powered 0 - otherwise" ::= { msanShMCBoardVariablesEntry 5 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.6 msanShMCBoardVariablesBoardBasicSlaveAddress OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The on board IPMI controller 7-bit I2C addresses for IPMB messages" ::= { msanShMCBoardVariablesEntry 6 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.7 msanShMCBoardVariablesBoardBasicFruDeviceId OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "FRU Device ID field is used to identify individual FRU devices on the given LUN in the management controller. Up to 255 FRU devices can be located on a given LUN. FRU Device ID #00 at LUN 00b is predefined as being the FRU Device for the FRU that the management controller is located on. Since there are four possible LUNs for a management controller, this means up to 255*4 FRU devices can be supported behind a single management controller using this mechanism. The Read/Write FRU Device commands provide an abstracted interface that hides the technology used to implement the FRU device from system software." ::= { msanShMCBoardVariablesEntry 7 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.8 msanShMCBoardVariablesBoardBasicFruinfoProductAreaPresent OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "1 - if product area is present 0 - otherwise" ::= { msanShMCBoardVariablesEntry 8 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.9 msanShMCBoardVariablesBoardBasicProductManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product manufacturer from the board FRU information or N/A" ::= { msanShMCBoardVariablesEntry 9 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.10 msanShMCBoardVariablesBoardBasicProductName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product name from the board FRU information or N/A" ::= { msanShMCBoardVariablesEntry 10 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.11 msanShMCBoardVariablesBoardBasicProductPartModelNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product part model from the board FRU information or N/A" ::= { msanShMCBoardVariablesEntry 11 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.12 msanShMCBoardVariablesBoardBasicProductVersionNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product version number from the board FRU information or N/A" ::= { msanShMCBoardVariablesEntry 12 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.13 msanShMCBoardVariablesBoardBasicProductSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product serial number from the board FRU information or N/A" ::= { msanShMCBoardVariablesEntry 13 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.14 msanShMCBoardVariablesBoardBasicBoardAreaPresent OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "1 - if board area is present 0 - otherwise" ::= { msanShMCBoardVariablesEntry 14 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.15 msanShMCBoardVariablesBoardBasicBoardManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board manufacturer from the board FRU information or N/A" ::= { msanShMCBoardVariablesEntry 15 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.16 msanShMCBoardVariablesBoardBasicBoardProductName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board product name from the board FRU information or N/A" ::= { msanShMCBoardVariablesEntry 16 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.17 msanShMCBoardVariablesBoardBasicBoardSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board serial number from the board FRU information or N/A" ::= { msanShMCBoardVariablesEntry 17 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.18 msanShMCBoardVariablesBoardBasicBoardPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board part number from the board FRU information or N/A" ::= { msanShMCBoardVariablesEntry 18 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.19 msanShMCBoardVariablesBoardBasicBoardManufactureTime OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board manufacturing time: the number of seconds since 00:00:00, January 1, 1970, CoordinatedUnivarsal Time (UTC): -1 if the corresponding field is not present in the board FRu information." ::= { msanShMCBoardVariablesEntry 19 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.32.1.20 msanShMCBoardVariablesSelectivePowerOffSwitchOffType OBJECT-TYPE SYNTAX INTEGER { automatic(1), switchOff(2), switchOn(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selective_Power_Off switch off type per board." DEFVAL { automatic } ::= { msanShMCBoardVariablesEntry 20 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33 msanShMCFanTrayVariablesTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCFanTrayVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Fan Trays" ::= { msanShMC 33 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1 msanShMCFanTrayVariablesEntry OBJECT-TYPE SYNTAX MsanShMCFanTrayVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An IPM Controller entry" INDEX { msanShMCFanTraySlotNumber } ::= { msanShMCFanTrayVariablesTable 1 } MsanShMCFanTrayVariablesEntry ::= SEQUENCE { msanShMCFanTraySlotNumber INTEGER, msanShMCFanTrayPresent INTEGER, msanShMCFanTrayHealthy INTEGER, msanShMCFanTrayHealthLed INTEGER, msanShMCFanTraySlaveAddress INTEGER, msanShMCFanTrayFruDeviceId INTEGER, msanShMCFanTrayFruinfoProductAreaPresent INTEGER, msanShMCFanTrayFruinfoProductManufacturer DisplayString, msanShMCFanTrayFruinfoProductName DisplayString, msanShMCFanTrayFruinfoProductPartModelNumber DisplayString, msanShMCFanTrayFruinfoProductVersionNumber DisplayString, msanShMCFanTrayFruinfoProductSerialNumber DisplayString, msanShMCFanTrayFruinfoBoardAreaPresent INTEGER, msanShMCFanTrayFruinfoBoardManufacturer DisplayString, msanShMCFanTrayFruinfoBoardProductName DisplayString, msanShMCFanTrayFruinfoBoardSerialNumber DisplayString, msanShMCFanTrayFruinfoBoardPartNumber DisplayString, msanShMCFanTrayFruinfoBoardManufactureTime Integer32 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.1 msanShMCFanTraySlotNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Table index equal to ,," ::= { msanShMCFanTrayVariablesEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.2 msanShMCFanTrayPresent OBJECT-TYPE SYNTAX INTEGER { absent(0), present(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "0 - Board is absent 1 - Board is present" ::= { msanShMCFanTrayVariablesEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.3 msanShMCFanTrayHealthy OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Causes the BMC to return a high level version of the system health status in integer. The BMC returns an integer with the following values: 0 - off 1 - on" ::= { msanShMCFanTrayVariablesEntry 3 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.4 msanShMCFanTrayHealthLed OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "on read: 1 - led is on 0 - led is off on write: 0 - turn led off 1 - turn led on" ::= { msanShMCFanTrayVariablesEntry 4 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.5 msanShMCFanTraySlaveAddress OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The on board IPMI controller 7-bit I2C addresses for IPMB messages" ::= { msanShMCFanTrayVariablesEntry 5 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.6 msanShMCFanTrayFruDeviceId OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "FRU Device ID field is used to identify individual FRU devices on the given LUN in the management controller. Up to 255 FRU devices can be located on a given LUN. FRU Device ID #00 at LUN 00b is predefined as being the FRU Device for the FRU that the management controller is located on. Since there are four possible LUNs for a management controller, this means up to 255*4 FRU devices can be supported behind a single management controller using this mechanism. The Read/Write FRU Device commands provide an abstracted interface that hides the technology used to implement the FRU device from system software." ::= { msanShMCFanTrayVariablesEntry 6 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.7 msanShMCFanTrayFruinfoProductAreaPresent OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "1 - if product area is present 0 - otherwise" ::= { msanShMCFanTrayVariablesEntry 7 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.8 msanShMCFanTrayFruinfoProductManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product manufacturer from the board FRU information or N/A" ::= { msanShMCFanTrayVariablesEntry 8 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.9 msanShMCFanTrayFruinfoProductName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product name from the board FRU information or N/A" ::= { msanShMCFanTrayVariablesEntry 9 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.10 msanShMCFanTrayFruinfoProductPartModelNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product part model from the board FRU information or N/A" ::= { msanShMCFanTrayVariablesEntry 10 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.11 msanShMCFanTrayFruinfoProductVersionNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product version number from the board FRU information or N/A" ::= { msanShMCFanTrayVariablesEntry 11 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.12 msanShMCFanTrayFruinfoProductSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product serial number from the board FRU information or N/A" ::= { msanShMCFanTrayVariablesEntry 12 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.13 msanShMCFanTrayFruinfoBoardAreaPresent OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "1 - if board area is present 0 - otherwise" ::= { msanShMCFanTrayVariablesEntry 13 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.14 msanShMCFanTrayFruinfoBoardManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board manufacturer from the board FRU information or N/A" ::= { msanShMCFanTrayVariablesEntry 14 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.15 msanShMCFanTrayFruinfoBoardProductName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board product name from the board FRU information or N/A" ::= { msanShMCFanTrayVariablesEntry 15 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.16 msanShMCFanTrayFruinfoBoardSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board serial number from the board FRU information or N/A" ::= { msanShMCFanTrayVariablesEntry 16 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.17 msanShMCFanTrayFruinfoBoardPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board part number from the board FRU information or N/A" ::= { msanShMCFanTrayVariablesEntry 17 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.33.1.18 msanShMCFanTrayFruinfoBoardManufactureTime OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board manufacturing time: the number of seconds since 00:00:00, January 1, 1970, CoordinatedUnivarsal Time (UTC): -1 if the corresponding field is not present in the board FRu information." ::= { msanShMCFanTrayVariablesEntry 18 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34 msanShMCPowerSupplyVariablesTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCPowerSupplyVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Power Supplys" ::= { msanShMC 34 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1 msanShMCPowerSupplyVariablesEntry OBJECT-TYPE SYNTAX MsanShMCPowerSupplyVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An IPM Controller entry" INDEX { msanShMCPowerSupplySlotNumber } ::= { msanShMCPowerSupplyVariablesTable 1 } MsanShMCPowerSupplyVariablesEntry ::= SEQUENCE { msanShMCPowerSupplySlotNumber INTEGER, msanShMCPowerSupplyDegrade INTEGER, msanShMCPowerSupplyFail INTEGER, msanShMCPowerSupplyInhibit INTEGER, msanShMCPowerSupplyHealthy INTEGER, msanShMCPowerSupplySlaveAddress INTEGER, msanShMCPowerSupplyFruDeviceId INTEGER, msanShMCPowerSupplyFruinfoProductAreaPresent INTEGER, msanShMCPowerSupplyFruinfoProductManufacturer DisplayString, msanShMCPowerSupplyFruinfoProductName DisplayString, msanShMCPowerSupplyFruinfoProductPartModelNumber DisplayString, msanShMCPowerSupplyFruinfoProductVersionNumber DisplayString, msanShMCPowerSupplyFruinfoProductSerialNumber DisplayString, msanShMCPowerSupplyFruinfoBoardAreaPresent INTEGER, msanShMCPowerSupplyFruinfoBoardManufacturer DisplayString, msanShMCPowerSupplyFruinfoBoardProductName DisplayString, msanShMCPowerSupplyFruinfoBoardSerialNumber DisplayString, msanShMCPowerSupplyFruinfoBoardPartNumber DisplayString, msanShMCPowerSupplyFruinfoBoardmanufactureTime Integer32 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.1 msanShMCPowerSupplySlotNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Table index equal to ,," ::= { msanShMCPowerSupplyVariablesEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.2 msanShMCPowerSupplyDegrade OBJECT-TYPE SYNTAX INTEGER { absent(0), present(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "0 - Board is absent 1 - Board is present" ::= { msanShMCPowerSupplyVariablesEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.3 msanShMCPowerSupplyFail OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Causes the BMC to return a high level version of the system health status in integer. The BMC returns an integer with the following values: 0 - off 1 - on" ::= { msanShMCPowerSupplyVariablesEntry 3 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.4 msanShMCPowerSupplyInhibit OBJECT-TYPE SYNTAX INTEGER { on(0), inhibit(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "on read: 1 - if power supply is in the Inhibited state 0 - otherwise on write: 1 - Inhibit power supply 0 - Reenable power supply" ::= { msanShMCPowerSupplyVariablesEntry 4 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.5 msanShMCPowerSupplyHealthy OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Causes the BMC to return a high level version of the system health status in integer. The BMC returns an integer with the following values: 0 - off 1 - on" ::= { msanShMCPowerSupplyVariablesEntry 5 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.6 msanShMCPowerSupplySlaveAddress OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The on board IPMI controller 7-bit I2C addresses for IPMB messages" ::= { msanShMCPowerSupplyVariablesEntry 6 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.7 msanShMCPowerSupplyFruDeviceId OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "FRU Device ID field is used to identify individual FRU devices on the given LUN in the management controller. Up to 255 FRU devices can be located on a given LUN. FRU Device ID #00 at LUN 00b is predefined as being the FRU Device for the FRU that the management controller is located on. Since there are four possible LUNs for a management controller, this means up to 255*4 FRU devices can be supported behind a single management controller using this mechanism. The Read/Write FRU Device commands provide an abstracted interface that hides the technology used to implement the FRU device from system software." ::= { msanShMCPowerSupplyVariablesEntry 7 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.8 msanShMCPowerSupplyFruinfoProductAreaPresent OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "1 - if product area is present 0 - otherwise" ::= { msanShMCPowerSupplyVariablesEntry 8 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.9 msanShMCPowerSupplyFruinfoProductManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product manufacturer from the board FRU information or N/A" ::= { msanShMCPowerSupplyVariablesEntry 9 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.10 msanShMCPowerSupplyFruinfoProductName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product name from the board FRU information or N/A" ::= { msanShMCPowerSupplyVariablesEntry 10 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.11 msanShMCPowerSupplyFruinfoProductPartModelNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product part model from the board FRU information or N/A" ::= { msanShMCPowerSupplyVariablesEntry 11 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.12 msanShMCPowerSupplyFruinfoProductVersionNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product version number from the board FRU information or N/A" ::= { msanShMCPowerSupplyVariablesEntry 12 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.13 msanShMCPowerSupplyFruinfoProductSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product serial number from the board FRU information or N/A" ::= { msanShMCPowerSupplyVariablesEntry 13 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.14 msanShMCPowerSupplyFruinfoBoardAreaPresent OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "1 - if board area is present 0 - otherwise" ::= { msanShMCPowerSupplyVariablesEntry 14 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.15 msanShMCPowerSupplyFruinfoBoardManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board manufacturer from the board FRU information or N/A" ::= { msanShMCPowerSupplyVariablesEntry 15 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.16 msanShMCPowerSupplyFruinfoBoardProductName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board product name from the board FRU information or N/A" ::= { msanShMCPowerSupplyVariablesEntry 16 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.17 msanShMCPowerSupplyFruinfoBoardSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board serial number from the board FRU information or N/A" ::= { msanShMCPowerSupplyVariablesEntry 17 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.18 msanShMCPowerSupplyFruinfoBoardPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board part number from the board FRU information or N/A" ::= { msanShMCPowerSupplyVariablesEntry 18 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.34.1.19 msanShMCPowerSupplyFruinfoBoardmanufactureTime OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board manufacturing time: the number of seconds since 00:00:00, January 1, 1970, CoordinatedUnivarsal Time (UTC): -1 if the corresponding field is not present in the board FRu information." ::= { msanShMCPowerSupplyVariablesEntry 19 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35 msanShMCShelfManagerVariablesTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCShelfManagerVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Shelf Managers" ::= { msanShMC 35 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1 msanShMCShelfManagerVariablesEntry OBJECT-TYPE SYNTAX MsanShMCShelfManagerVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An IPM Controller entry" INDEX { msanShMCShelfManagerSlotNumber } ::= { msanShMCShelfManagerVariablesTable 1 } MsanShMCShelfManagerVariablesEntry ::= SEQUENCE { msanShMCShelfManagerSlotNumber INTEGER, msanShMCShelfManagerSlaveAddress INTEGER, msanShMCShelfManagerPresent INTEGER, msanShMCShelfManagerHealthy INTEGER, msanShMCShelfManagerActive INTEGER, msanShMCShelfManagerReset INTEGER, msanShMCShelfManagerFruinfoProductAreaPresent INTEGER, msanShMCShelfManagerFruinfoProductManufacturer DisplayString, msanShMCShelfManagerFruinfoProductName DisplayString, msanShMCShelfManagerFruinfoProductPartModelNumber DisplayString, msanShMCShelfManagerFruinfoProductVersionNumber DisplayString, msanShMCShelfManagerFruinfoProductSerialNumber DisplayString, msanShMCShelfManagerFruinfoBoardAreaPresent INTEGER, msanShMCShelfManagerFruinfoBoardManufacturer DisplayString, msanShMCShelfManagerFruinfoBoardProductName DisplayString, msanShMCShelfManagerFruinfoBoardSerialNumber DisplayString, msanShMCShelfManagerFruinfoBoardPartNumber DisplayString, msanShMCShelfManagerFruinfoBoardmanufactureTime Integer32 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.1 msanShMCShelfManagerSlotNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Table index equal to ,," ::= { msanShMCShelfManagerVariablesEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.2 msanShMCShelfManagerSlaveAddress OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The on board IPMI controller 7-bit I2C addresses for IPMB messages" ::= { msanShMCShelfManagerVariablesEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.3 msanShMCShelfManagerPresent OBJECT-TYPE SYNTAX INTEGER { absent(0), present(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "0 - Shelf manager is absent 1 - Shelf manager is present" ::= { msanShMCShelfManagerVariablesEntry 3 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.4 msanShMCShelfManagerHealthy OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Causes the BMC to return a high level version of the system health status in integer. The BMC returns an integer with the following values: 0 - off 1 - on" ::= { msanShMCShelfManagerVariablesEntry 4 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.5 msanShMCShelfManagerActive OBJECT-TYPE SYNTAX INTEGER { standby(0), active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "on read: 1 - Shelf manager is active 0 - Shelf manager is in standby on write: 0 - initiate switchover other - no change" ::= { msanShMCShelfManagerVariablesEntry 5 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.6 msanShMCShelfManagerReset OBJECT-TYPE SYNTAX INTEGER { none(0), cold(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "on read: 1 - board is in reset state 0 - otherwise on write: 0 - do nothing 1 - perform COLD reset" ::= { msanShMCShelfManagerVariablesEntry 6 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.7 msanShMCShelfManagerFruinfoProductAreaPresent OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "1 - if product area is present 0 - otherwise" ::= { msanShMCShelfManagerVariablesEntry 7 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.8 msanShMCShelfManagerFruinfoProductManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product manufacturer from the board FRU information or N/A" ::= { msanShMCShelfManagerVariablesEntry 8 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.9 msanShMCShelfManagerFruinfoProductName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product name from the board FRU information or N/A" ::= { msanShMCShelfManagerVariablesEntry 9 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.10 msanShMCShelfManagerFruinfoProductPartModelNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product part model from the board FRU information or N/A" ::= { msanShMCShelfManagerVariablesEntry 10 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.11 msanShMCShelfManagerFruinfoProductVersionNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product version number from the board FRU information or N/A" ::= { msanShMCShelfManagerVariablesEntry 11 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.12 msanShMCShelfManagerFruinfoProductSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product serial number from the board FRU information or N/A" ::= { msanShMCShelfManagerVariablesEntry 12 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.13 msanShMCShelfManagerFruinfoBoardAreaPresent OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "1 - if board area is present 0 - otherwise" ::= { msanShMCShelfManagerVariablesEntry 13 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.14 msanShMCShelfManagerFruinfoBoardManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board manufacturer from the board FRU information or N/A" ::= { msanShMCShelfManagerVariablesEntry 14 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.15 msanShMCShelfManagerFruinfoBoardProductName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board product name from the board FRU information or N/A" ::= { msanShMCShelfManagerVariablesEntry 15 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.16 msanShMCShelfManagerFruinfoBoardSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board serial number from the board FRU information or N/A" ::= { msanShMCShelfManagerVariablesEntry 16 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.17 msanShMCShelfManagerFruinfoBoardPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board part number from the board FRU information or N/A" ::= { msanShMCShelfManagerVariablesEntry 17 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.35.1.18 msanShMCShelfManagerFruinfoBoardmanufactureTime OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board manufacturing time: the number of seconds since 00:00:00, January 1, 1970, CoordinatedUnivarsal Time (UTC): -1 if the corresponding field is not present in the board FRu information." ::= { msanShMCShelfManagerVariablesEntry 18 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36 msanShMCChassisVariablesTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCChassisVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Chassis report" ::= { msanShMC 36 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1 msanShMCChassisVariablesEntry OBJECT-TYPE SYNTAX MsanShMCChassisVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An IPM Controller entry" INDEX { msanShMCChassisId } ::= { msanShMCChassisVariablesTable 1 } MsanShMCChassisVariablesEntry ::= SEQUENCE { msanShMCChassisId INTEGER, msanShMCChassisType INTEGER, msanShMCChassisPartNumber DisplayString, msanShMCChassisSerialNumber DisplayString, msanShMCChassisProductAreaPresent INTEGER, msanShMCChassisProductManufacturer DisplayString, msanShMCChassisProductName DisplayString, msanShMCChassisProductPartModelNumber DisplayString, msanShMCChassisProductVersionNumber DisplayString, msanShMCChassisProductSerialNumber DisplayString, msanShMCChassisBoardAreaPresent INTEGER, msanShMCChassisBoardManufacturer DisplayString, msanShMCChassisBoardProductName DisplayString, msanShMCChassisBoardSerialNumber DisplayString, msanShMCChassisBoardPartNumber DisplayString, msanShMCChassisBoardmanufactureTime Integer32 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.1 msanShMCChassisId OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Shelf Address" ::= { msanShMCChassisVariablesEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.2 msanShMCChassisType OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The 8 bit Chassis type from the Shelf FRU Information" ::= { msanShMCChassisVariablesEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.3 msanShMCChassisPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis Part Number from the Shelf FRU Information" ::= { msanShMCChassisVariablesEntry 3 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.4 msanShMCChassisSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis Serial Number from the Shelf FRU Information" ::= { msanShMCChassisVariablesEntry 4 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.5 msanShMCChassisProductAreaPresent OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "1 - if product area is present 0 - otherwise" ::= { msanShMCChassisVariablesEntry 5 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.6 msanShMCChassisProductManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product manufacturer from the board FRU information or N/A" ::= { msanShMCChassisVariablesEntry 6 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.7 msanShMCChassisProductName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product name from the board FRU information or N/A" ::= { msanShMCChassisVariablesEntry 7 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.8 msanShMCChassisProductPartModelNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product part model from the board FRU information or N/A" ::= { msanShMCChassisVariablesEntry 8 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.9 msanShMCChassisProductVersionNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product version number from the board FRU information or N/A" ::= { msanShMCChassisVariablesEntry 9 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.10 msanShMCChassisProductSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the product serial number from the board FRU information or N/A" ::= { msanShMCChassisVariablesEntry 10 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.11 msanShMCChassisBoardAreaPresent OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "1 - if board area is present 0 - otherwise" ::= { msanShMCChassisVariablesEntry 11 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.12 msanShMCChassisBoardManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board manufacturer from the board FRU information or N/A" ::= { msanShMCChassisVariablesEntry 12 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.13 msanShMCChassisBoardProductName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board product name from the board FRU information or N/A" ::= { msanShMCChassisVariablesEntry 13 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.14 msanShMCChassisBoardSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board serial number from the board FRU information or N/A" ::= { msanShMCChassisVariablesEntry 14 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.15 msanShMCChassisBoardPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board part number from the board FRU information or N/A" ::= { msanShMCChassisVariablesEntry 15 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.36.1.16 msanShMCChassisBoardmanufactureTime OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board manufacturing time: the number of seconds since 00:00:00, January 1, 1970, CoordinatedUnivarsal Time (UTC): -1 if the corresponding field is not present in the board FRu information." ::= { msanShMCChassisVariablesEntry 16 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.37 msanShMCEventVariablesTable OBJECT-TYPE SYNTAX SEQUENCE OF MsanShMCEventVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Event report" ::= { msanShMC 37 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.37.1 msanShMCEventVariablesEntry OBJECT-TYPE SYNTAX MsanShMCEventVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An IPM Controller entry" INDEX { msanShMCEventIndex } ::= { msanShMCEventVariablesTable 1 } MsanShMCEventVariablesEntry ::= SEQUENCE { msanShMCEventIndex INTEGER, msanShMCEventDelete INTEGER, msanShMCEventTimeStamp Integer32, msanShMCEventClass INTEGER, msanShMCEventType INTEGER, msanShMCEventAsserted INTEGER, msanShMCEventOriginSiteType INTEGER, msanShMCEventOriginSiteNumber INTEGER, msanShMCEventOriginSlaveAddress INTEGER, msanShMCEventOriginFruId INTEGER, msanShMCEventOriginSensorNumber INTEGER } -- 1.3.6.1.4.1.1332.1.1.5.3.33.37.1.1 msanShMCEventIndex OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Table entry index, equal to " ::= { msanShMCEventVariablesEntry 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.37.1.2 msanShMCEventDelete OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "returns 0 on reading, Writing 1 causes the current SEL entry to be deleted" ::= { msanShMCEventVariablesEntry 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.37.1.3 msanShMCEventTimeStamp OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the board manufacturing time: the number of seconds since 00:00:00, January 1, 1970, CoordinatedUnivarsal Time (UTC): -1 if the corresponding field is not present in the board FRu information." ::= { msanShMCEventVariablesEntry 3 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.37.1.4 msanShMCEventClass OBJECT-TYPE SYNTAX INTEGER { other(0), temperature(1), voltage(2), current(3), fan(4), powerstate(225), hotswap(240) } MAX-ACCESS read-only STATUS current DESCRIPTION "Event class" ::= { msanShMCEventVariablesEntry 4 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.37.1.5 msanShMCEventType OBJECT-TYPE SYNTAX INTEGER { other(0), aboveUpperNonRecoverable(1), aboveUpperCritical(2), aboveUpperNonCritical(3), belowLowerNonrecoverable(4), belowLowerCritical(5), belowLowerNonCritical(6), inserted(7), activated(8), communicationLost(9), communicationRestored(10), deactivated(11), extracted(12), powerDegrade(13), powerFail(14), powerInhibit(15) } MAX-ACCESS read-only STATUS current DESCRIPTION "Event type" ::= { msanShMCEventVariablesEntry 5 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.37.1.6 msanShMCEventAsserted OBJECT-TYPE SYNTAX INTEGER { deasserted(0), asserted(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Event type" ::= { msanShMCEventVariablesEntry 6 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.37.1.7 msanShMCEventOriginSiteType OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Origin Site Type" ::= { msanShMCEventVariablesEntry 7 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.37.1.8 msanShMCEventOriginSiteNumber OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Origin Site Number" ::= { msanShMCEventVariablesEntry 8 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.37.1.9 msanShMCEventOriginSlaveAddress OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Origin Slave Address" ::= { msanShMCEventVariablesEntry 9 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.37.1.10 msanShMCEventOriginFruId OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Origin FRU ID" ::= { msanShMCEventVariablesEntry 10 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.37.1.11 msanShMCEventOriginSensorNumber OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Origin Sensor Number" ::= { msanShMCEventVariablesEntry 11 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.38 msanShMCGlobal OBJECT IDENTIFIER ::= { msanShMC 38 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.38.1 msanShMCSelectivePowerOffAdminMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selective_Power_Off power off delay." DEFVAL { disable } ::= { msanShMCGlobal 1 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.38.2 msanSHMCSelectivePowerOffOffDelay OBJECT-TYPE SYNTAX INTEGER (1..10) UNITS "minutes" MAX-ACCESS read-write STATUS current DESCRIPTION "Selective_Power_Off power off delay." DEFVAL { 5 } ::= { msanShMCGlobal 2 } -- 1.3.6.1.4.1.1332.1.1.5.3.33.38.3 msanSHMCSelectivePowerOffOnDelay OBJECT-TYPE SYNTAX INTEGER (1..10) UNITS "minutes" MAX-ACCESS read-write STATUS current DESCRIPTION "Selective_Power_Off power on delay." DEFVAL { 1 } ::= { msanShMCGlobal 3 } END -- -- ISKRATEL-IPMI-MIB.mib --