OCNOS-PSERV-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY, Gauge32, Counter32, Integer32, Unsigned32, IpAddress, Counter64, TimeTicks, NOTIFICATION-TYPE FROM SNMPv2-SMI DateAndTime, DisplayString, PhysAddress, RowStatus, TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF snmpTraps FROM SNMPv2-MIB enterprises, OBJECT-IDENTITY FROM SNMPv2-SMI Ipv6Address FROM IPV6-TC ipi FROM OCNOS-IPI-MODULE-MIB CmmChassisObject FROM CMM-CHASSIS-MIB; cmmSoftwareObjects MODULE-IDENTITY LAST-UPDATED "201804050000Z" ORGANIZATION "IP Infusion Inc." CONTACT-INFO "postal: 3965 Freedom Circle, Suite 200, Santa Clara, CA 95054 email: support@ipinfusion.com telephone: +1 408-400-1900 website: http://www.ipinfusion.com/" DESCRIPTION "This MIB module is for managing System Software status" REVISION "201804050000Z" DESCRIPTION "Initial Version" ::= { CmmChassisObject 4 } cmmSoftwareProcessKeepaliveTime OBJECT-TYPE SYNTAX Unsigned32(30..1800) MAX-ACCESS read-only STATUS current DESCRIPTION "software watchdog keep-alive time interval in seconds. Software watchdog monitors various OcNOS module and restarts module on detection of any software anomalies like crash or hang.Device is rebooted on detection of NSM/HSL crash or hang." DEFVAL { 60 } ::= { cmmSoftwareObjects 1 } cmmSoftwareProcessWatchdogStatus OBJECT-TYPE SYNTAX INTEGER {disabled(0), enabled(1)} MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates status of software watchdog monitoring . If value of this object is enabled then software watchdog is active and is monitoring software anomalies for various OcNOS modules." ::= { cmmSoftwareObjects 2 } cmmSoftwareProcessStatus OBJECT-TYPE SYNTAX INTEGER {false(0), true(1)} MAX-ACCESS read-only STATUS current DESCRIPTION "Global process status of all modules, if all process are running then this value will be true otherwise it wil be false" ::= { cmmSoftwareObjects 3 } cmmSoftwareProcessObjectsTable OBJECT-TYPE SYNTAX SEQUENCE OF CmmSoftwareProcessObjectsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides information for monitoring information for protocol Module running on the host" ::= { cmmSoftwareObjects 4 } cmmSoftwareProcessObjectsEntry OBJECT-TYPE SYNTAX CmmSoftwareProcessObjectsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information for monitoring information for protocol Module running on the host" INDEX { cmmSoftwareProcessID } ::= { cmmSoftwareProcessObjectsTable 1 } CmmSoftwareProcessObjectsEntry::= SEQUENCE { cmmSoftwareProcessID Unsigned32, cmmSoftwareProcessName OCTET STRING, cmmSoftwareProcessState INTEGER, cmmSoftwareProcessStartTime DateAndTime, cmmSoftwareProcessLastRestartReason OCTET STRING } cmmSoftwareProcessID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Each protocol module is uniquely identified with a number, also called as protocol module id" ::= { cmmSoftwareProcessObjectsEntry 1 } cmmSoftwareProcessName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Protocol module name" ::= { cmmSoftwareProcessObjectsEntry 2 } cmmSoftwareProcessState OBJECT-TYPE SYNTAX INTEGER {notrunning(0), running(1)} MAX-ACCESS read-only STATUS current DESCRIPTION "state of the process, whether its runnning or not running." ::= { cmmSoftwareProcessObjectsEntry 3 } cmmSoftwareProcessStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The starting time of a protocol module, given in date and time." ::= { cmmSoftwareProcessObjectsEntry 4 } cmmSoftwareProcessLastRestartReason OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Reason for process to shutdown provided it was running.This value will be the signal description" ::= { cmmSoftwareProcessObjectsEntry 5 } -- -- Notifications -- cmmSoftwareObjectsNotificationsPrefix OBJECT IDENTIFIER ::= { cmmSoftwareObjects 0 } cmmSysPsDownNotification NOTIFICATION-TYPE OBJECTS { cmmSoftwareProcessID, cmmSoftwareProcessName, cmmSoftwareProcessStartTime, cmmSoftwareProcessLastRestartReason } STATUS current DESCRIPTION "The cmmSysPsDownNotification event is generated when a protocol module down/hung/crashes" ::= { cmmSoftwareObjectsNotificationsPrefix 1 } cmmSysPsRestartNotification NOTIFICATION-TYPE OBJECTS { cmmSoftwareProcessID, cmmSoftwareProcessName, cmmSoftwareProcessStartTime } STATUS current DESCRIPTION "The cmmSysPsRestartNotification event is generated when a protocol module recovered from down/hung/crashes" ::= { cmmSoftwareObjectsNotificationsPrefix 2 } END