-- ICT MIB file for ICT Platinum Series. -- -- Date Version -- ============================= -- 3/29/19 v1.00 -- -- Renamed by Observium developers from ICT-MIB to ICT-PLATINUM-SERIES-MIB ICT-PLATINUM-SERIES-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; ictPower OBJECT IDENTIFIER ::= { enterprises 39145 } platinumSeries OBJECT IDENTIFIER ::= { ictPower 11 } deviceModel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Model Number" ::= { platinumSeries 1 } deviceName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Device Name" ::= { platinumSeries 2 } deviceHardware OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Hardware Version" ::= { platinumSeries 3 } deviceFirmware OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Firmware Version" ::= { platinumSeries 4 } deviceMacAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "MAC Address" ::= { platinumSeries 5 } inputVoltage OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Input Voltage (VAC)" ::= { platinumSeries 6 } outputVoltage OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Output Voltage (VDC)" ::= { platinumSeries 7 } outputCurrent OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "System Current (Amps)" ::= { platinumSeries 8 } outputEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Output Enable Status (a value of '1' indicates Output is Enabled, and a value of '2' indicates Output is Disabled)" ::= { platinumSeries 9 } batteryVoltage OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Battery Voltage (VDC)" ::= { platinumSeries 10 } batteryCurrent OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Battery Current (Amps)" ::= { platinumSeries 11 } batteryTemperature OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "Battery Temperature (ºC) (a value of '1000' indicates the temperature probe is not connected)" ::= { platinumSeries 12 } batterySoc OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Battery State of Charge (%)" ::= { platinumSeries 13 } batteryNetAh OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "Battery Net Ah Count (Ah)" ::= { platinumSeries 14 } batteryRunTime OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "Estimated Run-time Remaining (min)" ::= { platinumSeries 15 } inputVoltageX1 OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "Input Voltage (VAC)" ::= { platinumSeries 16 } outputVoltageX100 OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "Output Voltage (VDC X 100)" ::= { platinumSeries 17 } outputCurrentX100 OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "System Current (Amps X 100)" ::= { platinumSeries 18 } batteryVoltageX100 OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "Battery Voltage (VDC X 100)" ::= { platinumSeries 19 } batteryCurrentX100 OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "Battery Current (Amps X 100)" ::= { platinumSeries 20 } -- -- Trap definitions: -- acFailAlarmTrap TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when the AC Failure Alarm is triggered" ::= 101 dcFailAlarmTrap TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when the DC Failure Alarm is triggered" ::= 102 sysFailAlarmTrap TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when the System Failure Alarm is triggered" ::= 103 overtemperatureAlarmTrap TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when the Over-Temperature Alarm is triggered" ::= 104 commFailAlarmTrap TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when communications lost with a Parallel Unit" ::= 105 fanFailAlarmTrap TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when the Fan Failure Alarm is triggered" ::= 106 batteryAlarmTrap TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when a Battery Alarm is triggered" ::= 107 batteryCurrentAlarmTrap TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when the Battery Overcurrent Alarm is triggered" ::= 108 acFailAlarmClear TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when the AC Failure Alarm is cleared" ::= 111 dcFailAlarmClear TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when the DC Failure Alarm is cleared" ::= 112 sysFailAlarmClear TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when the System Failure Alarm is cleared" ::= 113 overtemperatureAlarmClear TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when the Over-Temperature Alarm is cleared" ::= 114 commFailAlarmClear TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when the Communications Failure Alarm is cleared" ::= 115 fanFailAlarmClear TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when the Fan Failure Alarm is cleared" ::= 116 batteryAlarmClear TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when the Battery Alarm is cleared" ::= 117 batteryTestStart TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when a Battery Discharge Test is started" ::= 121 batteryTestComplete TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when a Battery Discharge Test completes successfully" ::= 122 batteryTestFail TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when a Battery Discharge Test fails" ::= 123 batteryEqualizeStart TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when a Battery Equalize Charge is started" ::= 124 batteryEqualizeComplete TRAP-TYPE ENTERPRISE platinumSeries DESCRIPTION "Trap generated when a Battery Equalize Charge completes" ::= 125 END