HUAWEI-UPS-MIB DEFINITIONS ::= BEGIN IMPORTS huaweiUtility FROM HUAWEI-MIB OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC; hwUpsMIB MODULE-IDENTITY LAST-UPDATED "201210240000Z" ORGANIZATION "Huawei Technologies Co., Ltd." CONTACT-INFO "Floor 5, Block 4, R&D Building, Huawei Longgang Production Base, Shenzhen, P.R.C. http: // www.huawei.com Zip: 518129." DESCRIPTION "EMAP MIB defines MIB objects which provides load and backup management, patch management NMS interfaces. The current version is v1.01" REVISION "201210240000Z" DESCRIPTION "Huawei emap mib v1.00" ::= { huaweiUtility 174 } DisplayString ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Description." SYNTAX OCTET STRING (SIZE (1..64)) RowStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Description." SYNTAX INTEGER { active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6) } DateAndTime ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Description." SYNTAX OCTET STRING (SIZE (8..11)) RunStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This integer value represents running status of the system. Depending on situation there may be limits on allowed values. Operational values: (1) unknown - status has not yet been defined (2) normal - there are no activated alarms (3) alarm - alarm status " SYNTAX INTEGER { unknow(1), normal(2), alarm(3) } MeasuresRange ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Description." SYNTAX Integer32 TruthValue ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Description." SYNTAX INTEGER { true(1), false(2) } hwUpsMIBObjects OBJECT IDENTIFIER ::= { hwUpsMIB 1 } hwUpsSystem OBJECT IDENTIFIER ::= { hwUpsMIBObjects 1 } hwUpsSysIdent OBJECT IDENTIFIER ::= { hwUpsSystem 1 } hwUpsSystemMainDeviceESN OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "ESN of the master device used for setting up a NetEco model. A string of characters." ::= { hwUpsSysIdent 1 } hwUpsSystemType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the UPS system. A string of characters. Configurable." ::= { hwUpsSysIdent 2 } hwUpsSysInerProtVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Version number of the system interface protocol between the NetEco and NEs. A string of characters." ::= { hwUpsSysIdent 3 } hwUpsSysDeviceNum OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of devices in the system. An integer ranging from 0 to 63." ::= { hwUpsSysIdent 4 } hwUpsParallelSysNum OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of parallel systems. An integer ranging from 0 to 63." ::= { hwUpsSysIdent 5 } hwUpsEnvTemper OBJECT-TYPE SYNTAX Integer32 ( -500..1200) UNITS "C" MAX-ACCESS read-only STATUS current DESCRIPTION "Ambient temperature. An integer ranging from -50 to 120. The value is accurate to one decimal place on the NetEco. The unit is C" ::= { hwUpsSysIdent 6 } hwUpsEnvHumidity OBJECT-TYPE SYNTAX Unsigned32 (0..1000) UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "Ambient humidity. An integer ranging from 0 to 100. The value is accurate to one decimal place on the NetEco. The unit is %." ::= { hwUpsSysIdent 7 } hwUpsDevice OBJECT IDENTIFIER ::= { hwUpsMIBObjects 2 } hwUpsDeviceIdentTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsDeviceIdentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The device identification table. Use this table to get device ID, and to get device type, the soft version, the iner prot version, the ESN, the rating power of device, the parallel system index of device. This table's index is hwUpsDeviceId." ::= { hwUpsDevice 100 } hwUpsDeviceIdentEntry OBJECT-TYPE SYNTAX HwUpsDeviceIdentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The device identification table. Use this table to get device ID, and to get device type, the soft version, the iner prot version, the ESN, the rating power of device, the parallel system index of device. This table's index is hwUpsDeviceId." INDEX { hwUpsDeviceId } ::= { hwUpsDeviceIdentTable 1 } HwUpsDeviceIdentEntry ::= SEQUENCE { hwUpsDeviceId Unsigned32, hwUpsDeviceType OCTET STRING, hwUpsDeviceSoftVersion OCTET STRING, hwUpsDeviceInerProtVersion OCTET STRING, hwUpsDeviceESN OCTET STRING, hwUpsDevicePowerRating INTEGER, hwUpsDeviceParaSysIndex Unsigned32, hwUpsDeviceSysGrant Unsigned32, hwUpsDeviceMonitorSoftVersion OCTET STRING, hwUpsDevicePowerSoftVersion OCTET STRING, hwUpsDeviceIdentRowStatus RowStatus } hwUpsDeviceId OBJECT-TYPE SYNTAX Unsigned32 (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack ID, ranging from 1 to 100. This node is referenced as an index node by hwUpsDeviceIdentTable, hwUpsDeviceOperInfoTable, hwUpsInputTable, hwUpsOutputTable,hwUpsBypassTable, hwUpsBatteryTable, hwUpsControlTable, and hwUpsBattScheduleTestTable." ::= { hwUpsDeviceIdentEntry 1 } hwUpsDeviceType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Device model. A string of characters." ::= { hwUpsDeviceIdentEntry 2 } hwUpsDeviceSoftVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Device software version number. A string of characters." ::= { hwUpsDeviceIdentEntry 3 } hwUpsDeviceInerProtVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Interface protocol version number for the current device. A string of characters." ::= { hwUpsDeviceIdentEntry 4 } hwUpsDeviceESN OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "ESN. A string of characters." ::= { hwUpsDeviceIdentEntry 5 } hwUpsDevicePowerRating OBJECT-TYPE SYNTAX INTEGER { level80(1), level100(2), level120(3), level160(4), level200(5), level30(6), level40(7), level60(8), level240(9), level250(10), level280(11), level300(12) } MAX-ACCESS read-only STATUS current DESCRIPTION "System capacity. Enumeration type. The default value is 5. The unit is kVA. Value 1 indicates 80 kVA Value 2 indicates 100 kVA. Value 3 indicates 120 kVA. Value 4 indicates 160 kVA. Value 5 indicates 200 kVA." ::= { hwUpsDeviceIdentEntry 6 } hwUpsDeviceParaSysIndex OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "ID of the parallel system that the current device belongs to. An integer ranging from 0 to 63." ::= { hwUpsDeviceIdentEntry 7 } hwUpsDeviceSysGrant OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "System grant.An integer ranging from 0 to 10000." ::= { hwUpsDeviceIdentEntry 8 } hwUpsDeviceMonitorSoftVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Monitor software version number. A string of characters." ::= { hwUpsDeviceIdentEntry 9 } hwUpsDevicePowerSoftVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Power software version number A string of characters." ::= { hwUpsDeviceIdentEntry 10 } hwUpsDeviceIdentRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RowStatus of UPS device Identification table." ::= { hwUpsDeviceIdentEntry 100 } hwUpsDeviceOperInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsDeviceOperInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Device running information table. It's index is hwUpsDeviceId" ::= { hwUpsDevice 101 } hwUpsDeviceOperInfoEntry OBJECT-TYPE SYNTAX HwUpsDeviceOperInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Device running information table. It's index is hwUpsDeviceId" INDEX { hwUpsDeviceId } ::= { hwUpsDeviceOperInfoTable 1 } HwUpsDeviceOperInfoEntry ::= SEQUENCE { hwUpsDevicePowerSupplyMethod INTEGER, hwUpsDeviceRunningStatus INTEGER, hwUpsDeviceBatteryState INTEGER, hwUpsDeviceTemperature Unsigned32, hwUpsDeviceEnergyFloatState Unsigned32, hwUpsDeviceRedundantNumber Unsigned32, hwUpsDeviceDelayShutdownState Unsigned32, hwUpsDeviceDelayShutdownOrder INTEGER, hwUpsDeviceWorkMode INTEGER, hwUpsDeviceSmartPowerMode INTEGER, hwUpsDeviceBSCState INTEGER, hwUpsDeviceOperInfoRowStatus RowStatus } hwUpsDevicePowerSupplyMethod OBJECT-TYPE SYNTAX INTEGER { noOutput(1), bypass(2), normal(3), battery(4), sourceShare(5), normalECO(6), batteryECO(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Device power supply mode. Enumeration type. Value 1 indicates no power supply. Value 2 indicates bypass mode. Value 3 indicates normal mode. Value 4 indicates battery mode. Value 5 indicates combined mode. Value 6 indicates mains ECO mode. Value 7 indicates battery ECO mode." ::= { hwUpsDeviceOperInfoEntry 1 } hwUpsDeviceRunningStatus OBJECT-TYPE SYNTAX INTEGER { single(1), parallel(2), singleECO(3), parallelECO(4), aging(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "UPS operating status. Enumeration type. Value 1 indicates that a single UPS is operating. Value 2 indicates that the parallel system is operating. Value 3 indicates that a single UPS is operating in ECO mode. Value 4 indicates that the parallel system is operating in ECO mode. Value 5 indicates aging." ::= { hwUpsDeviceOperInfoEntry 2 } hwUpsDeviceBatteryState OBJECT-TYPE SYNTAX INTEGER { notExist(1), temperaryMode(2), sleep(3), floatCharge(4), boostCharge(5), discharge(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Battery status. Enumeration type. Value 1 indicates that no battery is connected. Value 2 indicates that the battery is not charging or discharging. Value 3 indicates hibernation. Value 4 indicates float charging. Value 5 indicates equalized charging. Value 6 indicates discharging." ::= { hwUpsDeviceOperInfoEntry 3 } hwUpsDeviceTemperature OBJECT-TYPE SYNTAX Unsigned32 (0..3000) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum temperature of the modules in the current device. An integer ranging from 0 to 300." ::= { hwUpsDeviceOperInfoEntry 4 } hwUpsDeviceEnergyFloatState OBJECT-TYPE SYNTAX Unsigned32 (0..70000) MAX-ACCESS read-only STATUS current DESCRIPTION "Current flow status. An integer ranging from 0 to 70000. " ::= { hwUpsDeviceOperInfoEntry 5 } hwUpsDeviceRedundantNumber OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Redundant number of the parallel system. An integer ranging from 0 to 3." ::= { hwUpsDeviceOperInfoEntry 6 } hwUpsDeviceDelayShutdownState OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Delay to shutdown state. An integer ranging from 0 to 4294967295" ::= { hwUpsDeviceOperInfoEntry 7 } hwUpsDeviceDelayShutdownOrder OBJECT-TYPE SYNTAX INTEGER { invalid(1), valid(2) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Delay to shutdown state. Enumeration type. Value 1 indicates invalid. Value 2 indicates valid." ::= { hwUpsDeviceOperInfoEntry 8 } hwUpsDeviceWorkMode OBJECT-TYPE SYNTAX INTEGER { normalMode(1), ecoMode(2), selfloadMode(3), converterMode(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Work Mode. Enumeration type. Value 1 indicates that normal mode. Value 2 indicates that eco mode. Value 3 indicates that self load mode. Value 4 indicates that converter mode. " ::= { hwUpsDeviceOperInfoEntry 9 } hwUpsDeviceSmartPowerMode OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Smart Power Mode.Enumeration type. Value 1 indicates that disable. Value 2 indicates that enable. " ::= { hwUpsDeviceOperInfoEntry 10 } hwUpsDeviceBSCState OBJECT-TYPE SYNTAX INTEGER { notExist(1), masterMode(2), slaveMode(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "BSC system status. Enumeration type. Value 1: Not activated Value 2: BSC master mode Value 3: BSC slave mode" ::= { hwUpsDeviceOperInfoEntry 11 } hwUpsDeviceOperInfoRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RowStatus of UPS device running information table." ::= { hwUpsDeviceOperInfoEntry 101 } hwUpsInput OBJECT IDENTIFIER ::= { hwUpsMIBObjects 3 } hwUpsInputTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS input information table. It's index is hwUpsDeviceId" ::= { hwUpsInput 100 } hwUpsInputEntry OBJECT-TYPE SYNTAX HwUpsInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS input information table. It's index is hwUpsDeviceId" INDEX { hwUpsDeviceId } ::= { hwUpsInputTable 1 } HwUpsInputEntry ::= SEQUENCE { hwUpsInputVoltageA Unsigned32, hwUpsInputVoltageB Unsigned32, hwUpsInputVoltageC Unsigned32, hwUpsInputFrequency Unsigned32, hwUpsInputCurrentA Unsigned32, hwUpsInputCurrentB Unsigned32, hwUpsInputCurrentC Unsigned32, hwUpsInputPowerFactorA Integer32, hwUpsInputPowerFactorB Integer32, hwUpsInputPowerFactorC Integer32, hwUpsInputLineVoltageAB Unsigned32, hwUpsInputLineVoltageBC Unsigned32, hwUpsInputLineVoltageCA Unsigned32, hwUpsInputRowStatus RowStatus } hwUpsInputVoltageA OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Input voltage phase A. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsInputEntry 1 } hwUpsInputVoltageB OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "Input voltage phase B. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsInputEntry 2 } hwUpsInputVoltageC OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "Input voltage phase C. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsInputEntry 3 } hwUpsInputFrequency OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Input frequency. The value ranges from 0 to 10000. The value is accurate to two decimal place on the NetEco. The unit is Hz." ::= { hwUpsInputEntry 4 } hwUpsInputCurrentA OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Input current phase A. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is A." ::= { hwUpsInputEntry 5 } hwUpsInputCurrentB OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "A" MAX-ACCESS read-only STATUS current DESCRIPTION "Input current phase B. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is A." ::= { hwUpsInputEntry 6 } hwUpsInputCurrentC OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "A" MAX-ACCESS read-only STATUS current DESCRIPTION "Input current phase C. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is A." ::= { hwUpsInputEntry 7 } hwUpsInputPowerFactorA OBJECT-TYPE SYNTAX Integer32 ( -100..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Phase A input power factor. The value ranges from -100 to 100. The value is accurate to one decimal place on the NetEco." ::= { hwUpsInputEntry 8 } hwUpsInputPowerFactorB OBJECT-TYPE SYNTAX Integer32 ( -100..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Phase B input power factor. The value ranges from -100 to 100. The value is accurate to one decimal place on the NetEco." ::= { hwUpsInputEntry 9 } hwUpsInputPowerFactorC OBJECT-TYPE SYNTAX Integer32 ( -100..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Phase C input power factor. The value ranges from -100 to 100. The value is accurate to one decimal place on the NetEco." ::= { hwUpsInputEntry 10 } hwUpsInputLineVoltageAB OBJECT-TYPE SYNTAX Unsigned32 (0..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "Input Line voltage AB. The value ranges from 0 to 20000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsInputEntry 11 } hwUpsInputLineVoltageBC OBJECT-TYPE SYNTAX Unsigned32 (0..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "Input Line voltage BC. The value ranges from 0 to 20000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsInputEntry 12 } hwUpsInputLineVoltageCA OBJECT-TYPE SYNTAX Unsigned32 (0..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "Input Line voltage CA. The value ranges from 0 to 20000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsInputEntry 13 } hwUpsInputRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RowStatus of UPS input information table." ::= { hwUpsInputEntry 100 } hwUpsOutput OBJECT IDENTIFIER ::= { hwUpsMIBObjects 4 } hwUpsOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS output information table. It's index is hwUpsDeviceId." ::= { hwUpsOutput 100 } hwUpsOutputEntry OBJECT-TYPE SYNTAX HwUpsOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS output information table. It's index is hwUpsDeviceId. " INDEX { hwUpsDeviceId } ::= { hwUpsOutputTable 1 } HwUpsOutputEntry ::= SEQUENCE { hwUpsOutputVoltageA Unsigned32, hwUpsOutputVoltageB Unsigned32, hwUpsOutputVoltageC Unsigned32, hwUpsOutputCurrentA Unsigned32, hwUpsOutputCurrentB Unsigned32, hwUpsOutputCurrentC Unsigned32, hwUpsOutputFrequency Unsigned32, hwUpsOutputActivePowerA Integer32, hwUpsOutputActivePowerB Integer32, hwUpsOutputActivePowerC Integer32, hwUpsOutputAppearancePowerA Integer32, hwUpsOutputAppearancePowerB Integer32, hwUpsOutputAppearancePowerC Integer32, hwUpsOutputLoadA Unsigned32, hwUpsOutputLoadB Unsigned32, hwUpsOutputLoadC Unsigned32, hwUpsOutputPowerRating INTEGER, hwUpsOutputFrequencyRating INTEGER, hwUpsOutputPowerFactorA Integer32, hwUpsOutputPowerFactorB Integer32, hwUpsOutputPowerFactorC Integer32, hwUpsOutputLineVoltageAB Unsigned32, hwUpsOutputLineVoltageBC Unsigned32, hwUpsOutputLineVoltageCA Unsigned32, hwUpsRackOutputPeakRatioA Unsigned32, hwUpsRackOutputPeakRatioB Unsigned32, hwUpsRackOutputPeakRatioC Unsigned32, hwUpsOutputRowStatus RowStatus } hwUpsOutputVoltageA OBJECT-TYPE SYNTAX Unsigned32 ( 0..10000) UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase A output voltage. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is V. " ::= { hwUpsOutputEntry 1 } hwUpsOutputVoltageB OBJECT-TYPE SYNTAX Unsigned32 ( 0..10000) UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase B output voltage. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsOutputEntry 2 } hwUpsOutputVoltageC OBJECT-TYPE SYNTAX Unsigned32 ( 0..10000) UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase C output voltage. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsOutputEntry 3 } hwUpsOutputCurrentA OBJECT-TYPE SYNTAX Unsigned32 ( 0..10000) UNITS "A" MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase A output current. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is A." ::= { hwUpsOutputEntry 4 } hwUpsOutputCurrentB OBJECT-TYPE SYNTAX Unsigned32 ( 0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase B output current. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is A." ::= { hwUpsOutputEntry 5 } hwUpsOutputCurrentC OBJECT-TYPE SYNTAX Unsigned32 ( 0..10000) UNITS "A" MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase C output current. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is A." ::= { hwUpsOutputEntry 6 } hwUpsOutputFrequency OBJECT-TYPE SYNTAX Unsigned32 ( 0..10000) UNITS "Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Rack output frequency. The value ranges from 0 to 10000. The value is accurate to two decimal place on the NetEco. The unit is Hz." ::= { hwUpsOutputEntry 7 } hwUpsOutputActivePowerA OBJECT-TYPE SYNTAX Integer32 ( -12000..12000) UNITS "kW" MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase A output active power. The value ranges from -12000 to 12000. The value is accurate to one decimal place on the NetEco. The unit is kW." ::= { hwUpsOutputEntry 8 } hwUpsOutputActivePowerB OBJECT-TYPE SYNTAX Integer32 ( -12000..12000) UNITS "kW" MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase B output active power. The value ranges from -12000 to 12000. The value is accurate to one decimal place on the NetEco. The unit is kW." ::= { hwUpsOutputEntry 9 } hwUpsOutputActivePowerC OBJECT-TYPE SYNTAX Integer32 ( -12000..12000) UNITS "kW" MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase C output active power. The value ranges from -12000 to 12000. The value is accurate to one decimal place on the NetEco. The unit is kW." ::= { hwUpsOutputEntry 10 } hwUpsOutputAppearancePowerA OBJECT-TYPE SYNTAX Integer32 ( -12000..12000) UNITS "kVA" MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase A output apparent power. The value ranges from -12000 to 12000. The value is accurate to one decimal place on the NetEco. The unit is kVA." ::= { hwUpsOutputEntry 11 } hwUpsOutputAppearancePowerB OBJECT-TYPE SYNTAX Integer32 ( -12000..12000) UNITS "kVA" MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase B output apparent power. The value ranges from -12000 to 12000. The value is accurate to one decimal place on the NetEco. The unit is kVA." ::= { hwUpsOutputEntry 12 } hwUpsOutputAppearancePowerC OBJECT-TYPE SYNTAX Integer32 ( -12000..12000) UNITS "kVA" MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase C output apparent power. The value ranges from -12000 to 12000. The value is accurate to one decimal place on the NetEco. The unit is kVA." ::= { hwUpsOutputEntry 13 } hwUpsOutputLoadA OBJECT-TYPE SYNTAX Unsigned32 (0..999) UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase A output load ratio. The value ranges from 0 to 5000 The value is accurate to one decimal place on the NetEco." ::= { hwUpsOutputEntry 14 } hwUpsOutputLoadB OBJECT-TYPE SYNTAX Unsigned32 (0..999) UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase B output load ratio. The value ranges from 0 to 5000 The value is accurate to one decimal place on the NetEco." ::= { hwUpsOutputEntry 15 } hwUpsOutputLoadC OBJECT-TYPE SYNTAX Unsigned32 (0..999) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase C output load ratio. The value ranges from 0 to 5000 The value is accurate to one decimal place on the NetEco." ::= { hwUpsOutputEntry 16 } hwUpsOutputPowerRating OBJECT-TYPE SYNTAX INTEGER { level200(1), level208(2), level220(3), level380(4), level400(5), level415(6), level480(7), level600(8), level690(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "Rated output voltage (system voltage level). Enumeration type. The default value is 6. The unit is V. Value 1 indicates 200 V. Value 2 indicates 208 V. Value 3 indicates 220 V. Value 4 indicates 380 V. Value 5 indicates 400 V. Value 6 indicates 415 V. Value 7 indicates 480 V. Value 8 indicates 600 V. Value 9 indicates 690 V." ::= { hwUpsOutputEntry 17 } hwUpsOutputFrequencyRating OBJECT-TYPE SYNTAX INTEGER { level50(1), level60(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Rated output frequency. Enumeration type. The default value is 2. The unit is Hz. Value 1 indicates 50 Hz. Value 2 indicates 60 Hz." ::= { hwUpsOutputEntry 18 } hwUpsOutputPowerFactorA OBJECT-TYPE SYNTAX Integer32 ( -100..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase A output power factor. The value ranges from -100 to 100 The value is accurate to two decimal place on the NetEco." ::= { hwUpsOutputEntry 19 } hwUpsOutputPowerFactorB OBJECT-TYPE SYNTAX Integer32 ( -100..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase B output power factor. The value ranges from -100 to 100 The value is accurate to two decimal place on the NetEco. " ::= { hwUpsOutputEntry 20 } hwUpsOutputPowerFactorC OBJECT-TYPE SYNTAX Integer32 ( -100..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase C output power factor. The value ranges from -100 to 100 The value is accurate to two decimal place on the NetEco." ::= { hwUpsOutputEntry 21 } hwUpsOutputLineVoltageAB OBJECT-TYPE SYNTAX Unsigned32 (0..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack Line AB output voltage. The value ranges from 0 to 20000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsOutputEntry 22 } hwUpsOutputLineVoltageBC OBJECT-TYPE SYNTAX Unsigned32 (0..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack Line BC output voltage. The value ranges from 0 to 20000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsOutputEntry 23 } hwUpsOutputLineVoltageCA OBJECT-TYPE SYNTAX Unsigned32 (0..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack Line CA output voltage. The value ranges from 0 to 20000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsOutputEntry 24 } hwUpsRackOutputPeakRatioA OBJECT-TYPE SYNTAX Unsigned32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack A Out Peak Ratio. The value ranges from 0 to 1000. The value is accurate to one decimal place on the NetEco. The unit is %." ::= { hwUpsOutputEntry 25 } hwUpsRackOutputPeakRatioB OBJECT-TYPE SYNTAX Unsigned32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack B Out Peak Ratio. The value ranges from 0 to 1000. The value is accurate to one decimal place on the NetEco. The unit is %." ::= { hwUpsOutputEntry 26 } hwUpsRackOutputPeakRatioC OBJECT-TYPE SYNTAX Unsigned32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack C Out Peak Ratio. The value ranges from 0 to 1000. The value is accurate to one decimal place on the NetEco. The unit is %." ::= { hwUpsOutputEntry 27 } hwUpsOutputRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RowStatus of UPS output information table." ::= { hwUpsOutputEntry 100 } hwUpsBypass OBJECT IDENTIFIER ::= { hwUpsMIBObjects 5 } hwUpsBypassTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsBypassEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS bypass information table. It's index is hwUpsDeviceId." ::= { hwUpsBypass 100 } hwUpsBypassEntry OBJECT-TYPE SYNTAX HwUpsBypassEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS bypass information table. It's index is hwUpsDeviceId." INDEX { hwUpsDeviceId } ::= { hwUpsBypassTable 1 } HwUpsBypassEntry ::= SEQUENCE { hwUpsBypassInputVoltageA Unsigned32, hwUpsBypassInputVoltageB Unsigned32, hwUpsBypassInputVoltageC Unsigned32, hwUpsBypassInputFrequency Unsigned32, hwUpsBypassInputCurrentA Unsigned32, hwUpsBypassInputCurrentB Unsigned32, hwUpsBypassInputCurrentC Unsigned32, hwUpsBypassInputLineVoltageAB Unsigned32, hwUpsBypassInputLineVoltageBC Unsigned32, hwUpsBypassInputLineVoltageCA Unsigned32, hwUpsBypassRowStatus RowStatus } hwUpsBypassInputVoltageA OBJECT-TYPE SYNTAX Unsigned32 ( 0..10000) UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "Bypass input voltage phase A. The value ranges from 0 to 10000 The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsBypassEntry 1 } hwUpsBypassInputVoltageB OBJECT-TYPE SYNTAX Unsigned32 ( 0..10000) UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "Bypass input voltage phase B. The value ranges from 0 to 10000 The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsBypassEntry 2 } hwUpsBypassInputVoltageC OBJECT-TYPE SYNTAX Unsigned32 ( 0..10000) UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "Bypass input voltage phase C. The value ranges from 0 to 10000 The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsBypassEntry 3 } hwUpsBypassInputFrequency OBJECT-TYPE SYNTAX Unsigned32 ( 0..10000) UNITS "Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Bypass input frequency. The value ranges from 0 to 10000 The value is accurate to two decimal place on the NetEco. The unit is Hz." ::= { hwUpsBypassEntry 4 } hwUpsBypassInputCurrentA OBJECT-TYPE SYNTAX Unsigned32 (0..60000) MAX-ACCESS read-only STATUS current DESCRIPTION "Bypass input current phase A. The value ranges from 0 to 60000 The value is accurate to one decimal place on the NetEco. The unit is A." ::= { hwUpsBypassEntry 5 } hwUpsBypassInputCurrentB OBJECT-TYPE SYNTAX Unsigned32 (0..60000) MAX-ACCESS read-only STATUS current DESCRIPTION "Bypass input current phase B. The value ranges from 0 to 60000 The value is accurate to one decimal place on the NetEco. The unit is A." ::= { hwUpsBypassEntry 6 } hwUpsBypassInputCurrentC OBJECT-TYPE SYNTAX Unsigned32 (0..60000) MAX-ACCESS read-only STATUS current DESCRIPTION "Bypass input current phase C. The value ranges from 0 to 60000 The value is accurate to one decimal place on the NetEco. The unit is A." ::= { hwUpsBypassEntry 7 } hwUpsBypassInputLineVoltageAB OBJECT-TYPE SYNTAX Unsigned32 (0..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "Bypass Input Line voltage AB. The value ranges from 0 to 20000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsBypassEntry 8 } hwUpsBypassInputLineVoltageBC OBJECT-TYPE SYNTAX Unsigned32 (0..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "Bypass Input Line voltage BC. The value ranges from 0 to 20000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsBypassEntry 9 } hwUpsBypassInputLineVoltageCA OBJECT-TYPE SYNTAX Unsigned32 (0..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "Bypass Input Line voltage CA. The value ranges from 0 to 20000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsBypassEntry 10 } hwUpsBypassRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RowStatus of UPS bypass information table." ::= { hwUpsBypassEntry 100 } hwUpsBattery OBJECT IDENTIFIER ::= { hwUpsMIBObjects 6 } hwUpsBatteryTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsBatteryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS battery information table. It's index is hwUpsDeviceId." ::= { hwUpsBattery 100 } hwUpsBatteryEntry OBJECT-TYPE SYNTAX HwUpsBatteryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS battery information table. It's index is hwUpsDeviceId." INDEX { hwUpsDeviceId } ::= { hwUpsBatteryTable 1 } HwUpsBatteryEntry ::= SEQUENCE { hwUpsBatteryVoltage Unsigned32, hwUpsBatteryCurrent Integer32, hwUpsBatteryCapacityLeft Unsigned32, hwUpsBatteryBackupTime Unsigned32, hwUpsBatteryNumber Unsigned32, hwUpsBatterytemperature Unsigned32, hwUpsBatterySoh INTEGER, hwUpsBatteryRowStatus RowStatus } hwUpsBatteryVoltage OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "Battery Voltage. It is a real-time analog parameter. Value range: 0 to 20000, Unit: V, and the value is accurate to one decimal place (.1)." ::= { hwUpsBatteryEntry 1 } hwUpsBatteryCurrent OBJECT-TYPE SYNTAX Integer32 (-60000..60000) UNITS "A" MAX-ACCESS read-only STATUS current DESCRIPTION "Battery Total Current. It is a real-time analog parameter. Value range: -60000 to 60000, Unit: A, and the value is accurate to one decimal place (.1)." ::= { hwUpsBatteryEntry 2 } hwUpsBatteryCapacityLeft OBJECT-TYPE SYNTAX Unsigned32 (0..100) UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "Battery Capacity Left. Value range: 0 to 100, Unit: %, and the value is an integer." ::= { hwUpsBatteryEntry 3 } hwUpsBatteryBackupTime OBJECT-TYPE SYNTAX Unsigned32 (0..172800) UNITS "S" MAX-ACCESS read-only STATUS current DESCRIPTION "Battery Backup Time. Value range: 0 to 172800, Unit: S, and the value is an integer." ::= { hwUpsBatteryEntry 4 } hwUpsBatteryNumber OBJECT-TYPE SYNTAX Unsigned32 (1..240) MAX-ACCESS read-only STATUS current DESCRIPTION "Battery group number.Value range: 1 to 240,and the value is an integer." ::= { hwUpsBatteryEntry 5 } hwUpsBatterytemperature OBJECT-TYPE SYNTAX Unsigned32 (-200..800) UNITS "C" MAX-ACCESS read-only STATUS current DESCRIPTION "Battery temperature.Value range: -20 to 80, Unit:C, and the value is accurate to one decimal place (.1)" ::= { hwUpsBatteryEntry 6 } hwUpsBatterySoh OBJECT-TYPE SYNTAX INTEGER { good(1), requiringMaintenance(2), repalceBatt(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { hwUpsBatteryEntry 7 } hwUpsBatteryRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RowStatus of UPS battery information table." ::= { hwUpsBatteryEntry 100 } -- 1.3.6.1.4.1.2011.6.174.1.10 hwUpsParallelSystem OBJECT IDENTIFIER ::= { hwUpsMIBObjects 10 } -- 1.3.6.1.4.1.2011.6.174.1.10.1 hwUpsParaSysTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsParaSysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS parallel system table. Its index is hwUpsDeviceId." ::= { hwUpsParallelSystem 1 } -- 1.3.6.1.4.1.2011.6.174.1.10.1.1 hwUpsParaSysEntry OBJECT-TYPE SYNTAX HwUpsParaSysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS parallel system table entry." INDEX { hwUpsDeviceId } ::= { hwUpsParaSysTable 1 } HwUpsParaSysEntry ::= SEQUENCE { hwUpsParaSysId Unsigned32, hwUpsParaSysOutActivePowA Integer32, hwUpsParaSysOutActivePowB Integer32, hwUpsParaSysOutActivePowC Integer32, hwUpsParaSysOutAppearPowA Integer32, hwUpsParaSysOutAppearPowB Integer32, hwUpsParaSysOutAppearPowC Integer32, hwUpsParaSysOutLoadFactorA Unsigned32, hwUpsParaSysOutLoadFactorB Unsigned32, hwUpsParaSysOutLoadFactorC Unsigned32, hwUpsParallelSystemRowStatus RowStatus } -- 1.3.6.1.4.1.2011.6.174.1.10.1.1.1 hwUpsParaSysId OBJECT-TYPE SYNTAX Unsigned32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "ID of the parallel system that the current rack belongs to. " ::= { hwUpsParaSysEntry 1 } -- 1.3.6.1.4.1.2011.6.174.1.10.1.1.2 hwUpsParaSysOutActivePowA OBJECT-TYPE SYNTAX Integer32 (-120000..120000) UNITS "kW" MAX-ACCESS read-only STATUS current DESCRIPTION "System phase A output active power.The value ranges from -12000 to 12000, The value is accurate to one decimal place on the NetEco. The unit is kW." ::= { hwUpsParaSysEntry 2 } -- 1.3.6.1.4.1.2011.6.174.1.10.1.1.3 hwUpsParaSysOutActivePowB OBJECT-TYPE SYNTAX Integer32 (-120000..120000) UNITS "kW" MAX-ACCESS read-only STATUS current DESCRIPTION "System phase B output active power.The value ranges from -12000 to 12000, The value is accurate to one decimal place on the NetEco. The unit is kW." ::= { hwUpsParaSysEntry 3 } -- 1.3.6.1.4.1.2011.6.174.1.10.1.1.4 hwUpsParaSysOutActivePowC OBJECT-TYPE SYNTAX Integer32 (-120000..120000) UNITS "kW" MAX-ACCESS read-only STATUS current DESCRIPTION "System phase C output active power.The value ranges from -12000 to 12000, The value is accurate to one decimal place on the NetEco. The unit is kW." ::= { hwUpsParaSysEntry 4 } -- 1.3.6.1.4.1.2011.6.174.1.10.1.1.5 hwUpsParaSysOutAppearPowA OBJECT-TYPE SYNTAX Integer32 (-120000..120000) UNITS "kVA" MAX-ACCESS read-only STATUS current DESCRIPTION "System phase A output apparent power.The value ranges from -12000 to 12000, The value is accurate to one decimal place on the NetEco. The unit is kVA." ::= { hwUpsParaSysEntry 5 } -- 1.3.6.1.4.1.2011.6.174.1.10.1.1.6 hwUpsParaSysOutAppearPowB OBJECT-TYPE SYNTAX Integer32 (-120000..120000) UNITS "kVA" MAX-ACCESS read-only STATUS current DESCRIPTION "System phase B output apparent power.The value ranges from -12000 to 12000, The value is accurate to one decimal place on the NetEco. The unit is kVA." ::= { hwUpsParaSysEntry 6 } -- 1.3.6.1.4.1.2011.6.174.1.10.1.1.7 hwUpsParaSysOutAppearPowC OBJECT-TYPE SYNTAX Integer32 (-120000..120000) UNITS "kVA" MAX-ACCESS read-only STATUS current DESCRIPTION "System phase C output apparent power.The value ranges from -12000 to 12000, The value is accurate to one decimal place on the NetEco. The unit is kVA." ::= { hwUpsParaSysEntry 7 } -- 1.3.6.1.4.1.2011.6.174.1.10.1.1.8 hwUpsParaSysOutLoadFactorA OBJECT-TYPE SYNTAX Unsigned32 (0..5000) UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "System phase A output reactive power.The value ranges from 0 to 500, The value is accurate to one decimal place on the NetEco. The unit is %." ::= { hwUpsParaSysEntry 8 } -- 1.3.6.1.4.1.2011.6.174.1.10.1.1.9 hwUpsParaSysOutLoadFactorB OBJECT-TYPE SYNTAX Unsigned32 (0..5000) UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "System phase B output reactive power.The value ranges from 0 to 500, The value is accurate to one decimal place on the NetEco. The unit is %." ::= { hwUpsParaSysEntry 9 } -- 1.3.6.1.4.1.2011.6.174.1.10.1.1.10 hwUpsParaSysOutLoadFactorC OBJECT-TYPE SYNTAX Unsigned32 (0..5000) UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "System phase C output reactive power.The value ranges from 0 to 500, The value is accurate to one decimal place on the NetEco. The unit is %." ::= { hwUpsParaSysEntry 10 } -- 1.3.6.1.4.1.2011.6.174.1.10.1.1.100 hwUpsParallelSystemRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RowStatus of ups parallel System Identification table." ::= { hwUpsParaSysEntry 100 } hwUpsSiteTime OBJECT IDENTIFIER ::= { hwUpsMIBObjects 11 } hwUpsSiteTimeUTC OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "UTC time, ranging from 0 to 4294967295. The unit is seconds." ::= { hwUpsSiteTime 1 } hwUpsSiteTimeZone OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS obsolete DESCRIPTION "UTC time zone that the current rack belongs to." ::= { hwUpsSiteTime 2 } hwUpsAlarm OBJECT IDENTIFIER ::= { hwUpsMIBObjects 12 } hwUpsAlarmSynchronNum OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm synchronization ID. The value ranges from 0 to 4294967295. This value is used by the NetEco to obtain the active alarm synchronization ID and synchronize alarms." ::= { hwUpsAlarm 1 } hwUpsAlarmCurrActiveNum OBJECT-TYPE SYNTAX Unsigned32 (0..8000) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of active alarms, ranging from 0 to 8000." ::= { hwUpsAlarm 2 } hwUpsAlarmCurrCriticalNum OBJECT-TYPE SYNTAX Unsigned32 (0..8000) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of critical active alarms, ranging from 0 to 8000." ::= { hwUpsAlarm 3 } hwUpsAlarmCurrMajorNum OBJECT-TYPE SYNTAX Unsigned32 (0..8000) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of major active alarms, ranging from 0 to 8000." ::= { hwUpsAlarm 4 } hwUpsAlarmCurrMinorNum OBJECT-TYPE SYNTAX Unsigned32 (0..8000) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of minor active alarms, ranging from 0 to 8000." ::= { hwUpsAlarm 5 } hwUpsAlarmCurrWarningNum OBJECT-TYPE SYNTAX Unsigned32 (0..8000) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of warning active alarms, ranging from 0 to 8000." ::= { hwUpsAlarm 6 } hwUpsActiveAlarm OBJECT IDENTIFIER ::= { hwUpsMIBObjects 13 } hwUpsActiveAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsActiveAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS active alarm table. It's indexs are hwUpsActiveAlarmDeviceId and hwUpsActiveAlarmSeqId" ::= { hwUpsActiveAlarm 1 } hwUpsActiveAlarmEntry OBJECT-TYPE SYNTAX HwUpsActiveAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS active alarm table. It's indexs are hwUpsActiveAlarmDeviceId and hwUpsActiveAlarmSeqId" INDEX { hwUpsActiveAlarmDeviceId, hwUpsActiveAlarmSeqId } ::= { hwUpsActiveAlarmTable 1 } HwUpsActiveAlarmEntry ::= SEQUENCE { hwUpsActiveAlarmDeviceId Unsigned32, hwUpsActiveAlarmSeqId Unsigned32, hwUpsActiveAlarmEquipID Unsigned32, hwUpsActiveAlarmID Unsigned32, hwUpsActiveAlarmReasonId Unsigned32, hwUpsActiveAlarmText OCTET STRING, hwUpsActiveAlarmLevel INTEGER, hwUpsActiveAlarmFlag INTEGER, hwUpsActiveAlarmSynchronNum Unsigned32, hwUpsActiveAlarmTime Unsigned32, hwUpsActiveAlarmRowStatus RowStatus } hwUpsActiveAlarmDeviceId OBJECT-TYPE SYNTAX Unsigned32 (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "ID of the device on which the active alarm is generated. An integer ranging from 1 to 100." ::= { hwUpsActiveAlarmEntry 1 } hwUpsActiveAlarmSeqId OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Sequence number of an active alarm, ranging from 1 to 4294967295." ::= { hwUpsActiveAlarmEntry 2 } hwUpsActiveAlarmEquipID OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Active alarm module ID, ranging from 1 to 10000." ::= { hwUpsActiveAlarmEntry 3 } hwUpsActiveAlarmID OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "ID of an active alarm, ranging from 0 to 4294967295." ::= { hwUpsActiveAlarmEntry 4 } hwUpsActiveAlarmReasonId OBJECT-TYPE SYNTAX Unsigned32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Reason ID of an active alarm, ranging from 1 to 100." ::= { hwUpsActiveAlarmEntry 5 } hwUpsActiveAlarmText OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "English name of an active alarm. A string of characters. " ::= { hwUpsActiveAlarmEntry 6 } hwUpsActiveAlarmLevel OBJECT-TYPE SYNTAX INTEGER { critical(1), major(2), minor(3), warning(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Severity of an active alarm. Enumeration type. Value 1 indicates a critical alarm. Value 2 indicates a major alarm. Value 3 indicates a minor alarm. Value 4 indicates a warning." ::= { hwUpsActiveAlarmEntry 7 } hwUpsActiveAlarmFlag OBJECT-TYPE SYNTAX INTEGER { occur(1), resume(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Flag bit of an active alarm. Enumeration type. Value 1 indicates that an active alarm is generated. Value 2 indicates that an active alarm is cleared." ::= { hwUpsActiveAlarmEntry 8 } hwUpsActiveAlarmSynchronNum OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Active alarm synchronization ID, ranging from 0 to 4294967295." ::= { hwUpsActiveAlarmEntry 9 } hwUpsActiveAlarmTime OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Time when an active alarm is generated, ranging from 0 to 4294967295. The unit is seconds. " ::= { hwUpsActiveAlarmEntry 10 } hwUpsActiveAlarmRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RowStatus of ups active alarm table." ::= { hwUpsActiveAlarmEntry 11 } hwUpsModule OBJECT IDENTIFIER ::= { hwUpsMIBObjects 107 } hwUpsModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { hwUpsModule 1 } hwUpsModuleEntry OBJECT-TYPE SYNTAX HwUpsModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { hwUpsModuleRackId } ::= { hwUpsModuleTable 1 } HwUpsModuleEntry ::= SEQUENCE { hwUpsModuleRackId Unsigned32, hwUpsPowerModuleId Unsigned32, hwUpsBusCapacitorLife Unsigned32, hwUpsInvACur Unsigned32, hwUpsInvBCur Unsigned32, hwUpsInvCCur Unsigned32, hwUpsModuleAUnevenFlow Unsigned32, hwUpsModuleBUnevenFlow Unsigned32, hwUpsModuleCUnevenFlow Unsigned32, hwUpsInvPowerStat INTEGER, hwUpsModuleUnevneCurValueTag Unsigned32, hwUpsModuleSleepState Unsigned32, hwUpsModuleRowStatus RowStatus } hwUpsModuleRackId OBJECT-TYPE SYNTAX Unsigned32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Ups Rack Id.Range from 1 to 6.This node is referenced as an index node by hwUpsModuleTable." ::= { hwUpsModuleEntry 1 } hwUpsPowerModuleId OBJECT-TYPE SYNTAX Unsigned32 (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Ups Power Module Id.Range from 1 to 20.This node is referenced as an index node by hwUpsModuleTable." ::= { hwUpsModuleEntry 2 } hwUpsBusCapacitorLife OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Inv C Cap Life.Value range: 0 to 10000, Unit: Y, and the value is accurate to one decimal place (.1)." ::= { hwUpsModuleEntry 3 } hwUpsInvACur OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Inv A Current.Value range: 0 to 10000.The value is accurate to one decimal place (.1).The unit is A." ::= { hwUpsModuleEntry 4 } hwUpsInvBCur OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Inv B Current.Value range: 0 to 10000.The value is accurate to one decimal place (.1).The unit is A." ::= { hwUpsModuleEntry 5 } hwUpsInvCCur OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Inv C Current.Value range: 0 to 10000.The value is accurate to one decimal place (.1).The unit is A." ::= { hwUpsModuleEntry 6 } hwUpsModuleAUnevenFlow OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Module A Uneven Flow.Value range: 0 to 10000,and the value is accurate to one decimal place (.1)." ::= { hwUpsModuleEntry 7 } hwUpsModuleBUnevenFlow OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Module B Uneven Flow.Value range: 0 to 10000,and the value is accurate to one decimal place (.1)." ::= { hwUpsModuleEntry 8 } hwUpsModuleCUnevenFlow OBJECT-TYPE SYNTAX Unsigned32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Module C Uneven Flow.Value range: 0 to 10000,and the value is accurate to one decimal place (.1)." ::= { hwUpsModuleEntry 9 } hwUpsInvPowerStat OBJECT-TYPE SYNTAX INTEGER { noOutput(1), bypass(2), normal(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Inv Power Stat.Enumeration type. Value 0 indicates no power supply. Value 1 indicates bypass mode. Value 2 indicates normal mode." ::= { hwUpsModuleEntry 10 } hwUpsModuleUnevneCurValueTag OBJECT-TYPE SYNTAX Unsigned32 (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Module uneven current value tag.range 0 to 1,0 indicates invalid,1 indicates valid." ::= { hwUpsModuleEntry 11 } hwUpsModuleSleepState OBJECT-TYPE SYNTAX Unsigned32 (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Module Sleep State.Range 0 to 1,0 indicates not sleep,1 indicates sleep." ::= { hwUpsModuleEntry 12 } hwUpsModuleRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RowStatus of UPS module information table." ::= { hwUpsModuleEntry 100 } hwUpsControl OBJECT IDENTIFIER ::= { hwUpsMIBObjects 102 } hwUpsControlTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS control table. It's index is hwUpsRackId." ::= { hwUpsControl 100 } hwUpsControlEntry OBJECT-TYPE SYNTAX HwUpsControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS control table. It's index is hwUpsRackId." INDEX { hwUpsDeviceId } ::= { hwUpsControlTable 1 } HwUpsControlEntry ::= SEQUENCE { hwUpsCtrlECOSwitch INTEGER, hwUpsCtrlPowerOn INTEGER, hwUpsCtrlPowerOff INTEGER, hwUpsCtrlPowerOffDelay Unsigned32, hwUpsCtrlPowerBatCapacity Unsigned32, hwUpsCtrlPowerBatType INTEGER, hwUpsCtrlModelType INTEGER, hwUpsCtrlInputStandard INTEGER, hwUpsCtrlOutputStandard INTEGER, hwUpsCtrlPowerOnState INTEGER, hwUpsCtrlBatteryToBoostState INTEGER, hwUpsCtrlBatteryToFloatState INTEGER, hwUpsCtrlBatteryToTestState INTEGER, hwUpsCtrlBatteryStopTestState INTEGER, hwUpsCtrlBatteryManualBoostCharge INTEGER, hwUpsCtrlBatteryManualFloatCharge INTEGER, hwUpsCtrlBatteryShallowTest INTEGER, hwUpsCtrlBatteryVerifyCapTest INTEGER, hwUpsCtrlBatteryEndTest INTEGER, hwUpsCtrlModelCapacity Unsigned32, hwUpsCtrlEPO INTEGER, hwUpsSmartParallelSleepMode INTEGER, hwUpsCtrlRowStatus RowStatus } hwUpsCtrlECOSwitch OBJECT-TYPE SYNTAX INTEGER { noECO(1), eco(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "ECO settings. Enumeration type. The default value is 1. Value 1 indicates ECO mode. Value 2 indicates Non ECO mode." ::= { hwUpsControlEntry 1 } hwUpsCtrlPowerOn OBJECT-TYPE SYNTAX INTEGER { powerOn(1), unknown(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Power on settings. Enumeration type. Value 1 indicates power on . Value 2 indicates unknow." ::= { hwUpsControlEntry 2 } hwUpsCtrlPowerOff OBJECT-TYPE SYNTAX INTEGER { powerOff(1), unknown(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Power off settings. Enumeration type. Value 1 indicates power off . Value 2 indicates unknow." ::= { hwUpsControlEntry 3 } hwUpsCtrlPowerOffDelay OBJECT-TYPE SYNTAX Unsigned32 (0..120000000) UNITS "S" MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Delay power off.The value ranges from 0 to 120000000 . The unit is S." ::= { hwUpsControlEntry 4 } hwUpsCtrlPowerBatCapacity OBJECT-TYPE SYNTAX Unsigned32 (5..3000) MAX-ACCESS read-only STATUS current DESCRIPTION "Battery capacity, ranging from 5 to 3000. " ::= { hwUpsControlEntry 5 } hwUpsCtrlPowerBatType OBJECT-TYPE SYNTAX INTEGER { vrla(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Battery type.ECO settings. Enumeration type. The default value is 1. Value 1 indicates VRLA batteries." ::= { hwUpsControlEntry 6 } hwUpsCtrlModelType OBJECT-TYPE SYNTAX INTEGER { model6K(17), mode110K(33), model20K(65) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Model type,Enumeration type. Value 17 indicates 6K. Value 33 indicates 10K. Value 65 indicates 20K." ::= { hwUpsControlEntry 7 } hwUpsCtrlInputStandard OBJECT-TYPE SYNTAX INTEGER { singlePhase(1), threePhase(2) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Input Standard,Enumeration type. Value 1 indicates single phase. Value 2 indicates three phase." ::= { hwUpsControlEntry 8 } hwUpsCtrlOutputStandard OBJECT-TYPE SYNTAX INTEGER { singlePhase(1) threePhase(2) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Output Standard,Enumeration type. Value 1 indicates single phase. Value 2 indicates three phase." ::= { hwUpsControlEntry 9 } hwUpsCtrlPowerOnState OBJECT-TYPE SYNTAX INTEGER { powerOff(1), powerOn(2), powerOnFail(3), powerOnComplete(4) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Power On State,Enumeration type. Value 1 indicates power off. Value 2 indicates booting. Value 3 indicates failed to power on. Value 4 indicates succeed tp power on." ::= { hwUpsControlEntry 10 } hwUpsCtrlBatteryToBoostState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Battery Change to Boost Charge State,Enumeration type. Value 1 indicates enabled. Value 2 indicates disabled." ::= { hwUpsControlEntry 11 } hwUpsCtrlBatteryToFloatState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Battery Change to Float Charge State,Enumeration type. Value 1 indicates enabled. Value 2 indicates disabled." ::= { hwUpsControlEntry 12 } hwUpsCtrlBatteryToTestState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), shallow(3) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Battery Change to Test State,Enumeration type. Value 1 indicates enabled. Value 2 indicates disabled." ::= { hwUpsControlEntry 13 } hwUpsCtrlBatteryStopTestState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Battery Stop Test State,Enumeration type. Value 1 indicates enabled. Value 2 indicates disabled." ::= { hwUpsControlEntry 14 } hwUpsCtrlBatteryManualBoostCharge OBJECT-TYPE SYNTAX INTEGER { toBoostCharge(1), unknown(255) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Battery Manual to Boost Charge,Enumeration type. Value 1 indicates enabled. Value 2 indicates disabled." ::= { hwUpsControlEntry 15 } hwUpsCtrlBatteryManualFloatCharge OBJECT-TYPE SYNTAX INTEGER { toFloatCharge(1), unknown(255) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Battery Manual to Float Charge,Enumeration type. Value 1 indicates enabled. Value 2 indicates unknown" ::= { hwUpsControlEntry 16 } hwUpsCtrlBatteryShallowTest OBJECT-TYPE SYNTAX INTEGER { toShallowTest(1), unknown(255) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Battery Shallow Test,Enumeration type. Value 1 indicates enabled. Value 2 indicates unknown" ::= { hwUpsControlEntry 17 } hwUpsCtrlBatteryVerifyCapTest OBJECT-TYPE SYNTAX INTEGER { toVerifyCapTest(1), unknown(255) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Battery Verify Cap Test,Enumeration type. Value 1 indicates enabled. Value 2 indicates unknown" ::= { hwUpsControlEntry 18 } hwUpsCtrlBatteryEndTest OBJECT-TYPE SYNTAX INTEGER { toEndTest(1), unknown(255) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Battery End Test,Enumeration type. Value 1 indicates enabled. Value 2 indicates unknown" ::= { hwUpsControlEntry 19 } hwUpsCtrlModelCapacity OBJECT-TYPE SYNTAX Unsigned32 (0..200) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Model Capacity.The value ranges from 0 to 200, The value is accurate to one decimal place on the NetEco. The unit is kVA." ::= { hwUpsControlEntry 20 } hwUpsCtrlEPO OBJECT-TYPE SYNTAX INTEGER { epo(1), unknown(2) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "EPO. Enumeration type. Value 1 indicates EPO . Value 255 indicates unknown." ::= { hwUpsControlEntry 21 } hwUpsSmartParallelSleepMode OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Smart Parallel Sleep Mode.Enumeration type.The default value is 0. Value 0 indicates disable. Value 1 indicates enable." ::= { hwUpsControlEntry 22 } hwUpsCtrlRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RowStatus of UPS rack control table." ::= { hwUpsControlEntry 100 } hwUpsTest OBJECT IDENTIFIER ::= { hwUpsMIBObjects 103 } hwUpsBattScheduleTestTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsBattScheduleTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Battery schedule test table. It's index is hwUpsDeviceId." ::= { hwUpsTest 101 } hwUpsBattScheduleTestEntry OBJECT-TYPE SYNTAX HwUpsBattScheduleTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Battery schedule test table. It's index is hwUpsDeviceId." INDEX { hwUpsDeviceId } ::= { hwUpsBattScheduleTestTable 1 } HwUpsBattScheduleTestEntry ::= SEQUENCE { hwUpsBattAutoTest INTEGER, hwUpsBattAutoTestTimeLimit INTEGER, hwUpsBattAutoTestTimeInterval Unsigned32, hwUpsBattAutoTestDischargeRate Unsigned32, hwUpsBattAutoTestEndVol Unsigned32, hwUpsBattTest INTEGER, hwUpsBattScheduleTestRowStatus RowStatus } hwUpsBattAutoTest OBJECT-TYPE SYNTAX INTEGER { disable(1), enalbe(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Scheduled shallow discharge test enabled or disabled. Enumeration value. The value 1 indicates that the test is disabled. The value 2 indicates that the test is enabled." ::= { hwUpsBattScheduleTestEntry 1 } hwUpsBattAutoTestTimeLimit OBJECT-TYPE SYNTAX INTEGER { from0to6(1), from6to12(2), from12to18(3), from18to24(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Scheduled shallow discharge test time. Enumeration value. Value 1 indicates 00:00 to 06:00. Value 2 indicates 06:00 to 12:00. Value 3 indicates 12:00 to 18:00. Value 4 indicates 18:00 to 00:00." ::= { hwUpsBattScheduleTestEntry 2 } hwUpsBattAutoTestTimeInterval OBJECT-TYPE SYNTAX Unsigned32 (30..90) UNITS "Day" MAX-ACCESS read-write STATUS current DESCRIPTION "Scheduled shallow discharge test interval. An integer ranging from 30 to 90. The unit is days." ::= { hwUpsBattScheduleTestEntry 3 } hwUpsBattAutoTestDischargeRate OBJECT-TYPE SYNTAX Unsigned32 (10..50) MAX-ACCESS read-write STATUS current DESCRIPTION "Shallow discharge test discharge ratio. An integer ranging from 10 to 50. . " ::= { hwUpsBattScheduleTestEntry 4 } hwUpsBattAutoTestEndVol OBJECT-TYPE SYNTAX Unsigned32 (160..195) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Maximum battery discharge time. An integer ranging from 160 to 195. The value is accurate to one decimal place on the NetEco. The unit is V/Cell. " ::= { hwUpsBattScheduleTestEntry 5 } hwUpsBattTest OBJECT-TYPE SYNTAX INTEGER { noTestInit(1), stopTest(2), scheduleTest(3), shallowDsgTest(4), verufyDsgTest(5) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "If you set the value to shallowDsgTest(4), you can perform a shallow discharge test; if you set the value to verifyDsgTest(5), you can perform a capacity test; if you set the value to stopTest(2), you can stop the test. Other settings are invalid. If you start a test when other tests are in progress, error code 4 is returned. During test, you can use this node to obtain the current or previous test type. If you have never started the battery test sheduleTest(3), shallowDsgTest(4), or verifyDsgTest(5), this node returns noTestInit(1)." ::= { hwUpsBattScheduleTestEntry 6 } hwUpsBattScheduleTestRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RowStatus of UPS Battery control table. " ::= { hwUpsBattScheduleTestEntry 100 } hwUpsiBOX OBJECT IDENTIFIER ::= { hwUpsMIBObjects 110 } hwUpsBatteryGroupNum OBJECT-TYPE SYNTAX Unsigned32 (0..4) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of battery group in UPS,ranging from 0 to 4. " ::= { hwUpsiBOX 1 } hwUpsBatteryNumInBatteryGroup OBJECT-TYPE SYNTAX Unsigned32 (0..300) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of battery in one battery group,ranging from 0 to 300. " ::= { hwUpsiBOX 2 } hwUpsiBOXNum OBJECT-TYPE SYNTAX Unsigned32 (0..4) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of iBOX in UPS,ranging from 0 to 4." ::= { hwUpsiBOX 3 } hwUpsBatteryGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsBatteryGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS battery group table. It's index is hwUpsBatteryGroupNo. " ::= { hwUpsiBOX 4 } hwUpsBatteryGroupEntry OBJECT-TYPE SYNTAX HwUpsBatteryGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS battery group table. It's index is hwUpsBatteryGroupNo. " INDEX { hwUpsBatteryGroupNo } ::= { hwUpsBatteryGroupTable 1 } HwUpsBatteryGroupEntry ::= SEQUENCE { hwUpsBatteryGroupNo Unsigned32, hwUpsBatteryGroupVolt Unsigned32, hwUpsBatteryGroupCur Integer32, hwUpsBatteryGroupSOC Unsigned32, hwUpsBatteryGroupBackupTime Unsigned32, hwUpsBatteryGroupSOH INTEGER, hwUpsBatteryGroupRowStatus RowStatus } hwUpsBatteryGroupNo OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "No of battery group,ranging from 1 to 4.This node is referenced as an index node by hwUpsBatteryGroupTable. " ::= { hwUpsBatteryGroupEntry 1 } hwUpsBatteryGroupVolt OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "The Voltage of battery group,ranging from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsBatteryGroupEntry 2 } hwUpsBatteryGroupCur OBJECT-TYPE SYNTAX Integer32 (-30000..30000) MAX-ACCESS read-only STATUS current DESCRIPTION "The Current of battery group,ranging from -30000 to 30000. The value is accurate to one decimal place on the NetEco. The unit is A." ::= { hwUpsBatteryGroupEntry 3 } hwUpsBatteryGroupSOC OBJECT-TYPE SYNTAX Unsigned32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The SOC of battery group,ranging from 0 to 100.The unit is %." ::= { hwUpsBatteryGroupEntry 4 } hwUpsBatteryGroupBackupTime OBJECT-TYPE SYNTAX Unsigned32 ( 0..999) MAX-ACCESS read-only STATUS current DESCRIPTION "The Backup Time of battery group,ranging from 0 to 999.The unit is min. " ::= { hwUpsBatteryGroupEntry 5 } hwUpsBatteryGroupSOH OBJECT-TYPE SYNTAX INTEGER { good(1), requiringMaintenance(2), needReplaceBatt(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SOH of battery group. Enumeration type. Value 0 indicates good. Value 1 indicates requiring maintenance. Value 2 indicates need replace batt. " ::= { hwUpsBatteryGroupEntry 6 } hwUpsBatteryGroupRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Row status of hwUpsBatteryGroupTable." ::= { hwUpsBatteryGroupEntry 100 } hwUpsiBOXTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsiBOXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CIM table. It's index is hwUpsCIMNo." ::= { hwUpsiBOX 5 } hwUpsiBOXEntry OBJECT-TYPE SYNTAX HwUpsiBOXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CIM table. It's index is hwUpsCIMNo." INDEX { hwUpsiBOXNo } ::= { hwUpsiBOXTable 1 } HwUpsiBOXEntry ::= SEQUENCE { hwUpsiBOXNo Unsigned32, hwUpsiBOXSoftVersion Unsigned32, hwUpsiBOXiBATNum Unsigned32, hwUpsiBOXRowStatus RowStatus } hwUpsiBOXNo OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "No of iBOX,ranging from 1 to 4.This node is referenced as an index node by hwUpsiBOXTable." ::= { hwUpsiBOXEntry 1 } hwUpsiBOXSoftVersion OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "The software version of iBOX,ranging from 0 to 4294967295." ::= { hwUpsiBOXEntry 2 } hwUpsiBOXiBATNum OBJECT-TYPE SYNTAX Unsigned32 (0..300) MAX-ACCESS read-only STATUS current DESCRIPTION "iBAT number of one iBOX,ranging from 0 to 300." ::= { hwUpsiBOXEntry 3 } hwUpsiBOXRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Row status of hwUpsiBOXTable." ::= { hwUpsiBOXEntry 100 } hwUpsBattGroupRelaiBOXTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsBattGroupRelaiBOXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS battery group related CIM Table. It's index is hwUpsBattGrpNo and hwUpsBattGroupRelaCIMNo. " ::= { hwUpsiBOX 6 } hwUpsBattGroupRelaiBOXEntry OBJECT-TYPE SYNTAX HwUpsBattGroupRelaiBOXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "UPS battery group related CIM Table. It's index is hwUpsBattGrpNo and hwUpsBattGroupRelaCIMNo. " INDEX { hwUpsBattGrpNo } ::= { hwUpsBattGroupRelaiBOXTable 1 } HwUpsBattGroupRelaiBOXEntry ::= SEQUENCE { hwUpsBattGrpNo Unsigned32, hwUpsBattGroupRelaiBOXNo Unsigned32, hwUpsBattGroupRelaiBATStartNo Unsigned32, hwUpsBattGroupRelaiBATEndNo Unsigned32, hwUpsBattGroupRelaiBOXRowStatus RowStatus } hwUpsBattGrpNo OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "No of battery group,ranging from 1 to 4.This node is referenced as an index node by hwUpsBattGrpRelaiBOXTable." ::= { hwUpsBattGroupRelaiBOXEntry 1 } hwUpsBattGroupRelaiBOXNo OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "No of iBOX,ranging from 1 to 4.This node is referenced as an index node by hwUpsBattGrpRelaiBOXTable." ::= { hwUpsBattGroupRelaiBOXEntry 2 } hwUpsBattGroupRelaiBATStartNo OBJECT-TYPE SYNTAX Unsigned32 (1..300) MAX-ACCESS read-only STATUS current DESCRIPTION "Ups Battery Group related iBAT start no,ranging from 1 to 300." ::= { hwUpsBattGroupRelaiBOXEntry 3 } hwUpsBattGroupRelaiBATEndNo OBJECT-TYPE SYNTAX Unsigned32 (1..300) MAX-ACCESS read-only STATUS current DESCRIPTION "Ups Battery Group related iBAT end no,ranging from 1 to 300. " ::= { hwUpsBattGroupRelaiBOXEntry 4 } hwUpsBattGroupRelaiBOXRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Row status of hwUpsBattGroupRelaiBOXTable." ::= { hwUpsBattGroupRelaiBOXEntry 100 } hwUpsiBATTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsiBATEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BIM table. It's index is hwUpsBIMCIMNo and hwUpsBIMNo." ::= { hwUpsiBOX 7 } hwUpsiBATEntry OBJECT-TYPE SYNTAX HwUpsiBATEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BIM table. It's index is hwUpsBIMCIMNo and hwUpsBIMNo." INDEX { hwUpsiBATiBOXNo } ::= { hwUpsiBATTable 1 } HwUpsiBATEntry ::= SEQUENCE { hwUpsiBATiBOXNo Unsigned32, hwUpsiBATNo Unsigned32, hwUpsiBATTemp Integer32, hwUpsiBATVoltMulThousand Unsigned32, hwUpsiBATResMulHundred Unsigned32, hwUpsiBATCur Integer32, hwUpsiBATSOC Unsigned32, hwUpsiBATSOH INTEGER, hwUpsiBATVolt Unsigned32, hwUpsiBATRes Unsigned32, hwUpsiBATRowStatus RowStatus } hwUpsiBATiBOXNo OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "No of iBOX,ranging from 1 to 4.This node is referenced as an index node by hwUpsBIMTable." ::= { hwUpsiBATEntry 1 } hwUpsiBATNo OBJECT-TYPE SYNTAX Unsigned32 (1..300) MAX-ACCESS read-only STATUS current DESCRIPTION "No of iBAT,ranging from 1 to 300. This node is referenced as an index node by hwUpsBIMTable." ::= { hwUpsiBATEntry 2 } hwUpsiBATTemp OBJECT-TYPE SYNTAX Integer32 (-200..800) MAX-ACCESS read-only STATUS current DESCRIPTION "Ups iBAT Temperature.The value ranges from -200 to 800. The value is accurate to one decimal place on the NetEco. The unit is ¡æ." ::= { hwUpsiBATEntry 3 } hwUpsiBATVoltMulThousand OBJECT-TYPE SYNTAX Unsigned32 (0..300) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Ups iBAT Volt.The value ranges from 0 to 300. The value is accurate to one decimal place on the NetEco. The unit is V." ::= { hwUpsiBATEntry 4 } hwUpsiBATResMulHundred OBJECT-TYPE SYNTAX Unsigned32 (0..3000) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Ups iBAT Resistance.The value ranges from 0 to 3000. The value is accurate to one decimal place on the NetEco. The unit is m¦¸." ::= { hwUpsiBATEntry 5 } hwUpsiBATCur OBJECT-TYPE SYNTAX Integer32 (-30000..30000) MAX-ACCESS read-only STATUS current DESCRIPTION "Ups iBAT Current.The value ranges from -30000 to 30000. The value is accurate to one decimal place on the NetEco. The unit is A. " ::= { hwUpsiBATEntry 6 } hwUpsiBATSOC OBJECT-TYPE SYNTAX Unsigned32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The SOC of iBAT,ranging from 0 to 100.The unit is %. " ::= { hwUpsiBATEntry 7 } hwUpsiBATSOH OBJECT-TYPE SYNTAX INTEGER { good(1), requiringMaintenance(2), needReplaceBatt(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SOH of iBAT. Enumeration type. Value 0 indicates good. Value 1 indicates requiring maintenance. Value 2 indicates need replace batt. " ::= { hwUpsiBATEntry 8 } hwUpsiBATVolt OBJECT-TYPE SYNTAX Unsigned32 (0..30000) MAX-ACCESS read-only STATUS current DESCRIPTION "Ups iBAT Volt.The value ranges from 0 to 30000. The value is accurate to two decimal place on the NetEco. The unit is V." ::= { hwUpsiBATEntry 9 } hwUpsiBATRes OBJECT-TYPE SYNTAX Unsigned32 (0..30000) MAX-ACCESS read-only STATUS current DESCRIPTION "Ups iBAT Resistance.The value ranges from 0 to 30000. The value is accurate to two decimal place on the NetEco. The unit is m¦¸." ::= { hwUpsiBATEntry 10 } hwUpsiBATRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Row status of hwUpsiBATTable." ::= { hwUpsiBATEntry 100 } hwUpsParallelSystem OBJECT IDENTIFIER ::= { hwUpsMIBObjects 10 } hwUpsParaSysTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsParaSysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "/" ::= { hwUpsParallelSystem 1 } hwUpsParaSysEntry OBJECT-TYPE SYNTAX HwUpsParaSysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "/" INDEX { hwUpsParaSysId } ::= { hwUpsParaSysTable 1 } HwUpsParaSysEntry ::= SEQUENCE { hwUpsParaSysId Unsigned32, hwUpsParaSysOutActivePowA Integer32, hwUpsParaSysOutActivePowB Integer32, hwUpsParaSysOutActivePowC Integer32, hwUpsParaSysOutAppearPowA Integer32, hwUpsParaSysOutAppearPowB Integer32, hwUpsParaSysOutAppearPowC Integer32, hwUpsParaSysOutLoadFactorA Unsigned32, hwUpsParaSysOutLoadFactorB Unsigned32, hwUpsParaSysOutLoadFactorC Unsigned32, hwUpsParallelSystemRowStatus RowStatus } hwUpsParaSysId OBJECT-TYPE SYNTAX Unsigned32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "ID of the parallel system that the current rack belongs to." ::= { hwUpsParaSysEntry 1 } hwUpsParaSysOutActivePowA OBJECT-TYPE SYNTAX Integer32 (-120000..120000) MAX-ACCESS read-only STATUS current DESCRIPTION "System phase A output active power.The value ranges from -12000 to 12000, The value is accurate to one decimal place on the NetEco. The unit is kW. " ::= { hwUpsParaSysEntry 2 } hwUpsParaSysOutActivePowB OBJECT-TYPE SYNTAX Integer32 (-120000..120000) MAX-ACCESS read-only STATUS current DESCRIPTION "System phase B output active power.The value ranges from -12000 to 12000, The value is accurate to one decimal place on the NetEco. The unit is kW. " ::= { hwUpsParaSysEntry 3 } hwUpsParaSysOutActivePowC OBJECT-TYPE SYNTAX Integer32 (-120000..120000) MAX-ACCESS read-only STATUS current DESCRIPTION "System phase C output active power.The value ranges from -12000 to 12000, The value is accurate to one decimal place on the NetEco. The unit is kW. " ::= { hwUpsParaSysEntry 4 } hwUpsParaSysOutAppearPowA OBJECT-TYPE SYNTAX Integer32 (-120000..120000) MAX-ACCESS read-only STATUS current DESCRIPTION "System phase A output apparent power.The value ranges from -12000 to 12000, The value is accurate to one decimal place on the NetEco. The unit is kVA. " ::= { hwUpsParaSysEntry 5 } hwUpsParaSysOutAppearPowB OBJECT-TYPE SYNTAX Integer32 (-120000..120000) MAX-ACCESS read-only STATUS current DESCRIPTION "System phase B output apparent power.The value ranges from -12000 to 12000, The value is accurate to one decimal place on the NetEco. The unit is kVA. " ::= { hwUpsParaSysEntry 6 } hwUpsParaSysOutAppearPowC OBJECT-TYPE SYNTAX Integer32 (-120000..120000) MAX-ACCESS read-only STATUS current DESCRIPTION "System phase C output apparent power.The value ranges from -12000 to 12000, The value is accurate to one decimal place on the NetEco. The unit is kVA. " ::= { hwUpsParaSysEntry 7 } hwUpsParaSysOutLoadFactorA OBJECT-TYPE SYNTAX Unsigned32 (0..5000) MAX-ACCESS read-only STATUS current DESCRIPTION "System A output load factor.The value ranges from 0 to 500, The value is accurate to one decimal place on the NetEco. The unit is %" ::= { hwUpsParaSysEntry 8 } hwUpsParaSysOutLoadFactorB OBJECT-TYPE SYNTAX Unsigned32 (0..5000) MAX-ACCESS read-only STATUS current DESCRIPTION "System B output load factor.The value ranges from 0 to 500, The value is accurate to one decimal place on the NetEco. The unit is %." ::= { hwUpsParaSysEntry 9 } hwUpsParaSysOutLoadFactorC OBJECT-TYPE SYNTAX Unsigned32 (0..5000) MAX-ACCESS read-only STATUS current DESCRIPTION "System C output load factor.The value ranges from 0 to 500, The value is accurate to one decimal place on the NetEco. The unit is %." ::= { hwUpsParaSysEntry 10 } hwUpsParallelSystemRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RowStatus of ups parallel System Identification table." ::= { hwUpsParaSysEntry 100 } hwUpsRackUnevenCur OBJECT IDENTIFIER ::= { hwUpsMIBObjects 108 } hwUpsRackUnevenCurTable OBJECT-TYPE SYNTAX SEQUENCE OF HwUpsRackUnevenCurEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { hwUpsRackUnevenCur 1 } hwUpsRackUnevenCurEntry OBJECT-TYPE SYNTAX HwUpsRackUnevenCurEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { hwUpsRackUnevenCurRackId } ::= { hwUpsRackUnevenCurTable 1 } HwUpsRackUnevenCurEntry ::= SEQUENCE { hwUpsRackUnevenCurRackId Unsigned32, hwUpsRackUnevenCurSysGrant Unsigned32, hwUpsRackUnevenCurPowerSupplyMode INTEGER, hwUpsRackUnevenCurPowerOnModNum Unsigned32, hwUpsRackUnevenCurSleepModNum Unsigned32, hwUpsRackOutputCurrentA Unsigned32, hwUpsRackOutputCurrentB Unsigned32, hwUpsRackOutputCurrentC Unsigned32, hwUpsRackUnevenCurA Unsigned32, hwUpsRackUnevenCurB Unsigned32, hwUpsRackUnevenCurC Unsigned32, hwUpsRackUnevenCurValueTag Unsigned32, hwUpsRackUnevenCurRowStatus RowStatus } hwUpsRackUnevenCurRackId OBJECT-TYPE SYNTAX Unsigned32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Ups Rack Id.Range from 1 to 6.This node is referenced as an index node by hwUpsRackUnevenCurTable" ::= { hwUpsRackUnevenCurEntry 1 } hwUpsRackUnevenCurSysGrant OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "System grant.An integer ranging from 0 to 10000." ::= { hwUpsRackUnevenCurEntry 2 } hwUpsRackUnevenCurPowerSupplyMode OBJECT-TYPE SYNTAX INTEGER { noOutput(1), bypass(2), normal(3), battery(4), sourceShare(5), normalECO(6), batteryECO(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Device power supply mode. Enumeration type. Value 1 indicates no power supply. Value 2 indicates bypass mode. Value 3 indicates normal mode. Value 4 indicates battery mode. Value 5 indicates combined mode. Value 6 indicates mains ECO mode. Value 7 indicates battery ECO mode." ::= { hwUpsRackUnevenCurEntry 3 } hwUpsRackUnevenCurPowerOnModNum OBJECT-TYPE SYNTAX Unsigned32 (0..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack PowerOn Module Num.Range from 0 to 20." ::= { hwUpsRackUnevenCurEntry 4 } hwUpsRackUnevenCurSleepModNum OBJECT-TYPE SYNTAX Unsigned32 (0..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack Sleep Module Num.Range from 0 to 20." ::= { hwUpsRackUnevenCurEntry 5 } hwUpsRackOutputCurrentA OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase A output current. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is A." ::= { hwUpsRackUnevenCurEntry 6 } hwUpsRackOutputCurrentB OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase B output current. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is A." ::= { hwUpsRackUnevenCurEntry 7 } hwUpsRackOutputCurrentC OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase C output current. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. The unit is A." ::= { hwUpsRackUnevenCurEntry 8 } hwUpsRackUnevenCurA OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase A uneven current. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. " ::= { hwUpsRackUnevenCurEntry 9 } hwUpsRackUnevenCurB OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase B uneven current. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. " ::= { hwUpsRackUnevenCurEntry 10 } hwUpsRackUnevenCurC OBJECT-TYPE SYNTAX Unsigned32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack phase C uneven current. The value ranges from 0 to 10000. The value is accurate to one decimal place on the NetEco. " ::= { hwUpsRackUnevenCurEntry 11 } hwUpsRackUnevenCurValueTag OBJECT-TYPE SYNTAX Unsigned32 (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Rack uneven current value tag.range 0 to 1,0 indicates invalid,1 indicates valid." ::= { hwUpsRackUnevenCurEntry 12 } hwUpsRackUnevenCurRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RowStatus of UPS Rack Uneven Current table." ::= { hwUpsRackUnevenCurEntry 100 } hwUpsMIBTraps OBJECT IDENTIFIER ::= { hwUpsMIB 2 } hwUpsTrapsVbOids OBJECT IDENTIFIER ::= { hwUpsMIBTraps 1 } hwUpsTrapsDeviceId OBJECT-TYPE SYNTAX Unsigned32 (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "ID of the device on which the active alarm is generated. An integer ranging from 1 to 100." ::= { hwUpsTrapsVbOids 1 } hwUpsTrapsModuleSeqId OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm module name, which produces alarm. This name may be one of Monitor module name,Bypass module name,ECU module name and Power module name. If it's value is empty, it indicates the alarm is a synthetical alarm and not belong to any module device." ::= { hwUpsTrapsVbOids 2 } hwUpsTrapsEquipID OBJECT-TYPE SYNTAX Unsigned32 (0..154) MAX-ACCESS read-only STATUS current DESCRIPTION "Active alarm module ID, ranging from 1 to 154." ::= { hwUpsTrapsVbOids 3 } hwUpsTrapsID OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "ID of an active alarm, ranging from 0 to 4294967295." ::= { hwUpsTrapsVbOids 4 } hwUpsTrapsReasonId OBJECT-TYPE SYNTAX Unsigned32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm reason ID. Value range: 0 to 100, and the value is an integer (.0)." ::= { hwUpsTrapsVbOids 5 } hwUpsTrapsText OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm name. It is of the character string type, and used to specify the content of a specific alarm." ::= { hwUpsTrapsVbOids 6 } hwUpsTrapsLevel OBJECT-TYPE SYNTAX INTEGER { critical(1), major(2), minor(3), warning(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm level, which users can configure the alarm severity, is an enumeration type: If the enumeration value is 1, it indicates a critical alarm; If the enumeration value is 2, it indicates a major alarm; If the enumeration value is 3, it indicates a minor alarm; If the enumeration value is 4, it indicates a warning." ::= { hwUpsTrapsVbOids 7 } hwUpsTrapsFlag OBJECT-TYPE SYNTAX INTEGER { occur(1), resume(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Flag bit of an active alarm. Enumeration type. Value 1 indicates that an active alarm is generated. Value 2 indicates that an active alarm is cleared." ::= { hwUpsTrapsVbOids 8 } hwUpsTrapsSynchronNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Active alarm synchronization ID, ranging from 0 to 4294967295" ::= { hwUpsTrapsVbOids 9 } hwUpsTrapsTime OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Time when an active alarm is generated, ranging from 0 to 4294967295. The unit is seconds." ::= { hwUpsTrapsVbOids 10 } hwUpsCommonTraps OBJECT IDENTIFIER ::= { hwUpsMIBTraps 2 } hwUpsCommonTrapsPrefix OBJECT IDENTIFIER ::= { hwUpsCommonTraps 0 } -- 1.3.6.1.4.1.2011.6.174.2.2.0.1 -- 1.3.6.1.4.1.2011.6.174.2.2.0.1 -- 1.3.6.1.4.1.2011.6.174.2.2.0.1 hwUpsSummaryAlarmTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "UPS Summary Alarm status changed. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. Additionally, in order to identify the status, UPS system operate status are also include in VB(variable bondings): If the enumeration value is Normal(2), it indicates that UPS system resumes form alarm. If the enumeration value is Alarm(3), it indicates that a new alarm occurs on the UPS sytem." ::= { hwUpsCommonTrapsPrefix 1 } -- 1.3.6.1.4.1.2011.6.174.2.2.0.2 -- 1.3.6.1.4.1.2011.6.174.2.2.0.2 -- 1.3.6.1.4.1.2011.6.174.2.2.0.2 hwUpsPowerModInslotChangeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Power module inslot status changed. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. Additionally, in order to identify the operation, power module operate status are also include in VB(variable bondings): If the enumeration value is Normal(2), it indicates that a new power module is inserted in slot; If the enumeration value is Alarm(3), it indicates that communication of the power module module fails or module is not in slot. " ::= { hwUpsCommonTrapsPrefix 2 } hwUpsPowerStatusWarnTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When UPS Power Status changed, a warn trap will be send. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 3 } hwUpsPowerStatusWarnResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "UPS Power Status warn resume trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 4 } hwUpsSwitchStatusWarnTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When contactor or switch status changed, a warn trap will be send. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 5 } hwUpsSwitchStatusWarnResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Contactor or switch warn resume trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 6 } hwUpsModCommFailedTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When module communicates failed, a trap will be send. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 7 } hwUpsModCommFailedResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Module communication failed Resume. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsCommonTrapsPrefix 8 } hwUpsModConfigWarnTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When module config status changed, a warn trap will be send. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsCommonTrapsPrefix 9 } hwUpsModConfigWarnResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Module config warn resume trap. Its correlation binding parameters:Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 10 } hwUpsRecWarnTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When rectifier status changed, a warn trap will be send. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 11 } hwUpsRecWarnResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Rectifier warn resume trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsCommonTrapsPrefix 12 } hwUpsChargerPowerWarnTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When charger power status changed, a warn trap will be send. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsCommonTrapsPrefix 13 } hwUpsChargerPowerWarnResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Charger power warn resume trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsCommonTrapsPrefix 14 } hwUpsGeneratorWarnTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When generator status changed, a warn trap will be send. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 15 } hwUpsGeneratorWarnResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Generator warn resume trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 16 } hwUpsInvWarnTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When inverter status changed, a warn trap will be send. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsCommonTrapsPrefix 17 } hwUpsInvWarnResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Inverter warn resume trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsCommonTrapsPrefix 18 } hwUpsLBSWarnTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When LBS status changed, a warn trap will be send. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 19 } hwUpsLBSWarnResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "LBS warn resume trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsCommonTrapsPrefix 20 } hwUpsSwitchTipWarnTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When switch method changed or there is a switch tip, a warn trap will be send. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 21 } hwUpsSwitchTipWarnResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Switch method or switch tip warn resume trap. Its correlation binding parameters:Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsCommonTrapsPrefix 22 } -- 1.3.6.1.4.1.2011.6.174.2.2.0.23 -- 1.3.6.1.4.1.2011.6.174.2.2.0.23 -- 1.3.6.1.4.1.2011.6.174.2.2.0.23 hwUpsBattDetachWarnTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "When battery detach, a warn trap will be send. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 23 } -- 1.3.6.1.4.1.2011.6.174.2.2.0.24 -- 1.3.6.1.4.1.2011.6.174.2.2.0.24 -- 1.3.6.1.4.1.2011.6.174.2.2.0.24 hwUpsBattDetachWarnResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Battery detach warn resume trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 24 } hwUpsBattStatusWarnTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When battery status abnormal, a warn trap will be send through this OID. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsCommonTrapsPrefix 25 } hwUpsBattStatusWarnResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When battery status abnormal resume, a trap will be send through this OID. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsCommonTrapsPrefix 26 } hwUpsBatteryTestWarnTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When battery test start, a warn trap will be send through this OID. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 27 } hwUpsBatteryTestWarnResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When battery test end, a trap will be send through this OID. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsCommonTrapsPrefix 28 } hwUpsRackComFailedTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When Rack communication fail happen, a alarm trap will be send. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 29 } hwUpsRackComFaiedResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Rack communication fail alarm resume. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 30 } hwUpsRackMasterConflictTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When Rack Master Conflict alarm happen, a alarm trap will be send. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsCommonTrapsPrefix 31 } hwUpsRackMasterConflictResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Rack Master Conflict alarm resume. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsCommonTrapsPrefix 32 } hwUpsRackNumNoMatchTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "UPS Rack num dismatch warn. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. Additionally, in order to identify the status, UPS system operate status are also include in VB(variable bondings): If the enumeration value is Normal(2), it indicates that UPS system resumes form alarm. If the enumeration value is Alarm(3), it indicates that a new alarm occurs on the UPS sytem." ::= { hwUpsCommonTrapsPrefix 33 } hwUpsRackNumNoMatchResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "UPS Rack num dismatch warn resume. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. Additionally, in order to identify the status, UPS system operate status are also include in VB(variable bondings): If the enumeration value is Normal(2), it indicates that UPS system resumes form alarm. If the enumeration value is Alarm(3), it indicates that a new alarm occurs on the UPS sytem. " ::= { hwUpsCommonTrapsPrefix 34 } -- 1.3.6.1.4.1.2011.6.174.2.2.1 hwUpsCommonStateTrapsPrefix OBJECT IDENTIFIER ::= { hwUpsCommonTraps 1 } -- 1.3.6.1.4.1.2011.6.174.2.2.0.35 -- 1.3.6.1.4.1.2011.6.174.2.2.0.35 -- 1.3.6.1.4.1.2011.6.174.2.2.1.1 hwUpsRackOnlineStateChangeTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "Ups Rack Online State Change Trap. Its correlation binding parameters: NULL" ::= { hwUpsCommonStateTrapsPrefix 1 } -- 1.3.6.1.4.1.2011.6.174.2.2.0.36 -- 1.3.6.1.4.1.2011.6.174.2.2.0.36 -- 1.3.6.1.4.1.2011.6.174.2.2.1.2 hwUpsRackConfigChangeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId } STATUS current DESCRIPTION "Ups Rack Config Change.Its correlation binding parameters: Device ID" ::= { hwUpsCommonStateTrapsPrefix 2 } -- 1.3.6.1.4.1.2011.6.174.2.2.0.37 -- 1.3.6.1.4.1.2011.6.174.2.2.0.37 -- 1.3.6.1.4.1.2011.6.174.2.2.1.3 hwUpsRackRunningStateChangeTrap NOTIFICATION-TYPE OBJECTS { hwUpsDeviceRunningStatus, hwUpsTrapsDeviceId } STATUS current DESCRIPTION "Ups Rack Running State Change.Its correlation binding parameters: Device ID and Device running state." ::= { hwUpsCommonStateTrapsPrefix 3 } -- 1.3.6.1.4.1.2011.6.174.2.2.0.38 -- 1.3.6.1.4.1.2011.6.174.2.2.0.38 -- 1.3.6.1.4.1.2011.6.174.2.2.1.4 hwUpsBatteryRunningStateChangeTrap NOTIFICATION-TYPE OBJECTS { hwUpsDeviceBatteryState, hwUpsTrapsDeviceId } STATUS current DESCRIPTION "Ups Battery Running State Change,Its correlation binding parameters: Device ID and Battery Running State" ::= { hwUpsCommonStateTrapsPrefix 4 } -- 1.3.6.1.4.1.2011.6.174.2.2.1.5 hwUpsEnergyFloatChangeTrap NOTIFICATION-TYPE OBJECTS { hwUpsDeviceEnergyFloatState, hwUpsTrapsDeviceId } STATUS current DESCRIPTION "Ups Energy Float Change,Its correlation binding parameters: Device ID and The Energy Float State" ::= { hwUpsCommonStateTrapsPrefix 5 } -- 1.3.6.1.4.1.2011.6.174.2.2.1.6 hwUpsVersionChangeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId } STATUS current DESCRIPTION "Ups Version Change,Its correlation binding parameters: Device ID" ::= { hwUpsCommonStateTrapsPrefix 6 } hwUpsAlarmTraps OBJECT IDENTIFIER ::= { hwUpsMIBTraps 3 } hwUpsAlarmTrapsPrefix OBJECT IDENTIFIER ::= { hwUpsAlarmTraps 0 } hwUpsModNumAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When power module number dismatch, a alarm trap will be send. Its correlation binding parameters:Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 1 } hwUpsModNumAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Power module number dismatch alarm resume trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 2 } hwUpsBypassUnitAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Bypass Unit Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 3 } hwUpsBypassUnitAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Bypass Unit Abnormal Resume Trap. Its correlation binding parameters:Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 4 } hwUpsInRackParallelLineAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "In-Rack Parallel Line Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 5 } hwUpsInRackParallelLineAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Description: In-Rack Parallel Line Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 6 } hwUpsBetweenRackParallelLineAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Between-Rack Parallel Line Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 7 } hwUpsBetweenRackParallelLineAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Between-Rack Parallel Line Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 8 } hwUpsFanAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Fan Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 9 } hwUpsFanAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Fan Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 10 } hwUpsAuxiliaryPowerAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Auxiliary Power Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 11 } hwUpsAuxiliaryPowerAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Auxiliary Power Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 12 } hwUpsVersionMismatchAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "when version mismatch alarms happen, a alarm trap will be send. Its correlation binding parameters:Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 13 } hwUpsVersionMatchAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Version mismatch Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 14 } hwUpsAddrConflictAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Address Conflict Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 15 } hwUpsAddrConflictAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Address Conflict Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 16 } hwUpsEmergencyPowerOffAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Emergency Power Off Abnormal Trap. Its correlation binding parameters:Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 17 } hwUpsEmergencyPowerOffAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Emergency Power Off Abnormal Resume Trap. Its correlation binding parameters:Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 18 } hwUpsBypassInputAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Bypass Input Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 19 } hwUpsBypassInputAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Bypass Input Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 20 } -- 1.3.6.1.4.1.2011.6.174.2.3.0.21 -- 1.3.6.1.4.1.2011.6.174.2.3.0.21 -- 1.3.6.1.4.1.2011.6.174.2.3.0.21 hwUpsInputIsolatingTransAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Transformer Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 21 } -- 1.3.6.1.4.1.2011.6.174.2.3.0.22 -- 1.3.6.1.4.1.2011.6.174.2.3.0.22 -- 1.3.6.1.4.1.2011.6.174.2.3.0.22 hwUpsInputIsolatingTransAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Transformer Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 22 } hwUpsInternalAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Supervision Unit Internal Fault Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 23 } hwUpsInternalAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Supervision Unit Internal Fault Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 24 } hwUpsRectifierAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Rectifier Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 25 } hwUpsRectifierAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Rectifier Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 26 } hwUpsChargerAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Charger Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 27 } hwUpsChargerAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Charger Abnormal Resume Trap. Its correlation binding parameters:Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 28 } hwUpsDischargerAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Discharger Abnormal Trap. Its correlation binding parameters:Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 29 } hwUpsDischargerAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Discharger Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 30 } hwUpsACAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "AC Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 31 } hwUpsACAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "AC Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 32 } hwUpsModuleNotReadyAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Module Not Ready Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 33 } hwUpsModuleNotReadyAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Module Not Ready Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 34 } hwUpsInverterAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Inverter Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 35 } hwUpsInverterAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Inverter Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 36 } hwUpsECUAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "ECU Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 37 } hwUpsECUAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "ECU Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 38 } hwUpsSPDAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "SPD Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 39 } hwUpsSPDAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "SPD Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 40 } hwUpsOperationFaultAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Operation Fault Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 41 } hwUpsOperationFaultAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Operation Fault Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 42 } hwUpsOverLoadAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Over Load Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 43 } hwUpsOverLoadAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Over Load Abnormal Resume Trap. Its correlation binding parameters:Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 44 } hwUpsOverLoadOverTimeAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Over-Load Overtime Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 45 } hwUpsOverLoadOverTimeAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Over-Load Overtime Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 46 } hwUpsLBSAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "LBS Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 47 } hwUpsLBSAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "LBS Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 48 } hwUpsBypSwitchAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Bypass Switch Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 49 } hwUpsBypSwitchAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Bypass Switch Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 50 } hwUpsBatteryFault1AlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When battery reversed, no Battery, battery earth fault or battery stop discharge abnormal happen, an alarm trap will be send through this OID. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 51 } hwUpsBatteryFault1AlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When battery reversed, no Battery, battery earth fault or battery stop discharge abnormal resume, a trap will be send through this OID. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 52 } hwUpsBatteryFault2AlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When battery over temperature, battery need maintenance, or battery voltage low abnormal happen, an alarm trap will be send through this OID. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 53 } hwUpsBatteryFault2AlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "When battery over temperature, battery need maintenance, or battery voltage low abnormal resume, a trap will be send through this OID. Its correlation binding parameters:Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 54 } hwUpsBatteryChangeLimitAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Battery Change Limit Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 55 } hwUpsBatteryChangeLimitAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Battery Change Limit Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 56 } -- 1.3.6.1.4.1.2011.6.174.2.3.0.57 hwUpsRectifierStartLimitAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Rectifier Start Limit Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 57 } -- 1.3.6.1.4.1.2011.6.174.2.3.0.58 hwUpsRectifierStartLimitAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Rectifier Start Limit Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 58 } -- 1.3.6.1.4.1.2011.6.174.2.3.0.59 hwUpsMainLoadCapicityAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Main Load Capicity Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 59 } -- 1.3.6.1.4.1.2011.6.174.2.3.0.60 hwUpsMainLoadCapicityAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Main Load Capicity Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 60 } -- 1.3.6.1.4.1.2011.6.174.2.3.0.61 hwUpsBatteryChangeAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Batterry Change Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 61 } -- 1.3.6.1.4.1.2011.6.174.2.3.0.62 hwUpsBatteryChangeAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Batterry Change Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 62 } hwUpsBatteryMaintainAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Batterry Maintain Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 63 } hwUpsBatteryMaintainAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Batterry Maintain Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 64 } -- 1.3.6.1.4.1.2011.6.174.2.3.0.65 hwUpsMinorLoadOffAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Minor Load Off Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 65 } -- 1.3.6.1.4.1.2011.6.174.2.3.0.66 hwUpsMinorLoadOffAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Minor Load Off Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 66 } -- 1.3.6.1.4.1.2011.6.174.2.3.0.67 hwUpsParaStatusSetAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Parallel Status Set Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 67 } -- 1.3.6.1.4.1.2011.6.174.2.3.0.68 hwUpsParaStatusSetAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Parallel Status Set Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 68 } hwUpsRemainCapacityAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Remain Capacity Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 69 } hwUpsRemainCapacityAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Remain Capacity Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 70 } hwUpsParParaAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Parallel Parameter Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time. " ::= { hwUpsAlarmTrapsPrefix 71 } hwUpsParParaAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Parallel Parameter Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the tim" ::= { hwUpsAlarmTrapsPrefix 72 } -- 1.3.6.1.4.1.2011.6.174.2.3.0.73 hwUpsFlashAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Flash Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 73 } -- 1.3.6.1.4.1.2011.6.174.2.3.0.74 hwUpsFlashAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId, hwUpsTrapsModuleSeqId, hwUpsTrapsEquipID, hwUpsTrapsID, hwUpsTrapsReasonId, hwUpsTrapsText, hwUpsTrapsLevel, hwUpsTrapsFlag, hwUpsTrapsSynchronNum, hwUpsTrapsTime } STATUS current DESCRIPTION "Flash Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 74 } hwUpsManulPowerOnOffTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Manul Power On Off Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 75 } hwUpsManulPowerOnOffResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Manul Power On Off Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 76 } hwUpsIOAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "IO signal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 77 } hwUpsIOAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "IO Signal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 78 } hwUpsEnvironmentDataAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Environment Date Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 79 } hwUpsEnvironmentDataAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Environment Date Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 80 } hwUpsUpdatingAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Updating Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 81 } hwUpsUpdatingAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Updating Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 82 } hwUpsProgramAbnormalTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Program Abnormal Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 83 } hwUpsProgramAbnormalResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Program Abnormal Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 84 } hwUpsBcbFaultAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Bcb Fault Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 85 } hwUpsBcbFaultAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Bcb Fault Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 86 } hwUpsEcoRangeAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "ECO Range Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 87 } hwUpsEcoRangeAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "ECO Range Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 88 } hwUpsBMUAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Bmu Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 89 } hwUpsBMUAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Bmu Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 90 } hwUpsElableFailedAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Elable Failed Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 91 } hwUpsElableFailedAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Elable Failed Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time" ::= { hwUpsAlarmTrapsPrefix 92 } hwUpsDIPConflictAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "DIP Conflict Trap" ::= { hwUpsAlarmTrapsPrefix 93 } hwUpsDIPConflictAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "DIP Conflict Resume Trap." ::= { hwUpsAlarmTrapsPrefix 94 } hwUpsSystemStatusTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Ups System Status Trap." ::= { hwUpsAlarmTrapsPrefix 95 } hwUpsSystemStatusResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Ups System Status Resume Trap." ::= { hwUpsAlarmTrapsPrefix 96 } hwUpsIBOXAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Ups IBOX Alarm Trap." ::= { hwUpsAlarmTrapsPrefix 97 } hwUpsIBOXAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Ups IBOX Alarm Resume Trap" ::= { hwUpsAlarmTrapsPrefix 98 } hwUpsBattRackAlarmTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Expand Borad Alarm Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 99 } hwUpsBattRackAlarmResumeTrap NOTIFICATION-TYPE OBJECTS { hwUpsTrapsDeviceId,hwUpsTrapsModuleSeqId,hwUpsTrapsEquipID,hwUpsTrapsID,hwUpsTrapsReasonId,hwUpsTrapsText,hwUpsTrapsLevel,hwUpsTrapsFlag,hwUpsTrapsSynchronNum,hwUpsTrapsTime } STATUS current DESCRIPTION "Expand Borad Alarm Resume Trap. Its correlation binding parameters: Device ID, Sequence ID, Equip ID, Trap ID, Trap Reason ID, Trap Text, Trap Level, Trap Flag, Synchron NO and the time." ::= { hwUpsAlarmTrapsPrefix 100 } END