-- ============================================================================ -- Copyright (C) 2011 by HUAWEI TECHNOLOGIES. All rights reserved. -- Description: This MIB module defines MIB objects which provides R2 attribute management. -- Reference: -- Version: V1.02 -- ============================================================================ HUAWEI-R2-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, private FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF TEXTUAL-CONVENTION FROM SNMPv2-TC IpAddress,TimeTicks,Counter32,Integer32 FROM SNMPv2-SMI RowStatus,DisplayString FROM SNMPv2-TC huaweiUtility FROM HUAWEI-MIB; hwR2Protocol MODULE-IDENTITY LAST-UPDATED "201111230000Z" ORGANIZATION "Huawei Technologies Co., Ltd." CONTACT-INFO "Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com Email: support@huawei.com " DESCRIPTION " This MIB module defines MIB objects which provides R2 attribute management. " -- Revision history REVISION "201207310000Z" DESCRIPTION "V1.02, modify the description of hwRegisterOutgoingSignalType and hwRegisterIncomingSignalType" REVISION "201111230000Z" DESCRIPTION "V1.00, R2 attribute configure create a new mib document " ::= { huaweiUtility 108 } hwR2Objects OBJECT IDENTIFIER ::= { hwR2Protocol 1 } hwR2ProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF HwR2ProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " R2 signaling profile table,this table is used to add,modify,del,query R2 profile templet. The index of this table is hwR2ProfileIndex " ::= { hwR2Objects 1 } hwR2ProfileEntry OBJECT-TYPE SYNTAX HwR2ProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " R2 signaling profile table,this table is used to add,modify,del,query R2 profile templet. The index of this entry is hwR2ProfileIndex " INDEX { hwR2ProfileIndex } ::= { hwR2ProfileTable 1 } HwR2ProfileEntry ::= SEQUENCE { hwR2ProfileIndex Integer32, hwSignalName OCTET STRING, hwSignalType Integer32, hwR2SignalProfileRowStatus RowStatus } hwR2ProfileIndex OBJECT-TYPE SYNTAX Integer32(0..15) MAX-ACCESS not-accessible STATUS current DESCRIPTION " R2 signaling profile index " ::= { hwR2ProfileEntry 1 } hwSignalName OBJECT-TYPE SYNTAX OCTET STRING(SIZE (1..32)) MAX-ACCESS read-write STATUS current DESCRIPTION " R2 signaling profile name " ::= { hwR2ProfileEntry 2 } hwSignalType OBJECT-TYPE SYNTAX Integer32(0..15) MAX-ACCESS read-write STATUS current DESCRIPTION " R2 signaling type " ::= { hwR2ProfileEntry 3 } hwR2SignalProfileRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION " Row status of R2 signaling profile " ::= { hwR2ProfileEntry 4 } hwRegisterSignalAttributeTable OBJECT-TYPE SYNTAX SEQUENCE OF HwRegisterSignalAttributeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " R2 register signaling attribute table,this table is used to set and query r2 profile register attribute The index of this table is hwRegisterSignalIndex " ::= { hwR2Objects 2 } hwRegisterSignalAttributeEntry OBJECT-TYPE SYNTAX HwRegisterSignalAttributeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " R2 register signaling attribute table,this table is used to set and query r2 profile register attribute The index of this entry is hwRegisterSignalIndex " INDEX { hwRegisterSignalIndex } ::= { hwRegisterSignalAttributeTable 1 } HwRegisterSignalAttributeEntry ::= SEQUENCE { hwRegisterSignalIndex Integer32, hwRegisterOutgoingSignalType INTEGER, hwSignalSendVoltage Integer32, hwBackPulseTime Integer32, hwDTMFSendTime Integer32, hwDTMFSendInterval Integer32, hwNoCallerPermit INTEGER, hwNumberMaxInterval Integer32, hwSignalKeepMaxTime Integer32, hwReceiveNumberMaxInterval Integer32, hwSignalStopPermitTime Integer32, hwWaitCallerCategoryTime Integer32, hwWaitBsignalTime Integer32, hwNumberSendMode INTEGER, hwCallingNumberMaxLength Integer32, hwCompellingSequenceKeepaliveTime Integer32, hwSendPulseSignal INTEGER, hwRegisterIncomingSignalType INTEGER } hwRegisterSignalIndex OBJECT-TYPE SYNTAX Integer32(0..15) MAX-ACCESS not-accessible STATUS current DESCRIPTION " R2 signaling profile index " ::= { hwRegisterSignalAttributeEntry 1 } hwRegisterOutgoingSignalType OBJECT-TYPE SYNTAX INTEGER{mfc(1),pulse(2),dtmf(3),mfp(4),dpmfp(5)} MAX-ACCESS read-write STATUS current DESCRIPTION " Signaling type of outgoing office register Options: 1. mfc(1)-the register outgoing signal type is mfc 2. pulse(2) -the register outgoing signal type is pulse 3. dtmf(3) -the register outgoing signal type is dtmf 4. mfp(4) -the register outgoing signal type is mfp 5. dpmfp(5) -the register outgoing signal type is dpmfp " DEFVAL { mfc } ::= { hwRegisterSignalAttributeEntry 2 } hwSignalSendVoltage OBJECT-TYPE SYNTAX Integer32(1..23) MAX-ACCESS read-write STATUS current DESCRIPTION " Register signal transmit level(dbm) 1:-25dBm 2:-24dBm 3:-23dBm 4:-22dBm 5:-21dBm 6:-20dBm 7:-19dBm 8:-18dBm 9:-17dBm 10:-16dBm 11:-15dBm 12:-14dBm 13:-13dBm 14:-12dBm 15:-11dBm 16:-10dBm 17:-9dBm 18:-8dBm 19:-7dBm 20:-6dBm 21:-5dBm 22:-4dBm 23:-3dBm} " DEFVAL { 14 } ::= { hwRegisterSignalAttributeEntry 3 } hwBackPulseTime OBJECT-TYPE SYNTAX Integer32(100..200) MAX-ACCESS read-write STATUS current DESCRIPTION " Backword pulse duration(Multiple of 10; unit: ms) " DEFVAL { 150 } ::= { hwRegisterSignalAttributeEntry 4 } hwDTMFSendTime OBJECT-TYPE SYNTAX Integer32(50..200) MAX-ACCESS read-write STATUS current DESCRIPTION " DTMF signal transmit duration (ms) " DEFVAL { 68 } ::= { hwRegisterSignalAttributeEntry 5 } hwDTMFSendInterval OBJECT-TYPE SYNTAX Integer32(50..500) MAX-ACCESS read-write STATUS current DESCRIPTION " DTMF signal transmit interval (ms) " DEFVAL { 68 } ::= { hwRegisterSignalAttributeEntry 6 } hwNoCallerPermit OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-write STATUS obsolete DESCRIPTION " Can the call be established without a calling party Options: 1. yes(1)- permit send caller number 2. no(2) - not permit send caller number " ::= { hwRegisterSignalAttributeEntry 7 } hwNumberMaxInterval OBJECT-TYPE SYNTAX Integer32(1..60) MAX-ACCESS read-write STATUS current DESCRIPTION " Max. dialing interval (s) " DEFVAL { 50 } ::= { hwRegisterSignalAttributeEntry 8 } hwSignalKeepMaxTime OBJECT-TYPE SYNTAX Integer32(1..30) MAX-ACCESS read-write STATUS obsolete DESCRIPTION " Max. signal duration (s) " ::= { hwRegisterSignalAttributeEntry 9 } hwReceiveNumberMaxInterval OBJECT-TYPE SYNTAX Integer32(1..60) MAX-ACCESS read-write STATUS obsolete DESCRIPTION " Max. interval of receiving calling(callee) signals (s) " ::= { hwRegisterSignalAttributeEntry 10 } hwSignalStopPermitTime OBJECT-TYPE SYNTAX Integer32(1..30) MAX-ACCESS read-write STATUS obsolete DESCRIPTION " Max. duration of signal interruption " ::= { hwRegisterSignalAttributeEntry 11 } hwWaitCallerCategoryTime OBJECT-TYPE SYNTAX Integer32(1..60) MAX-ACCESS read-write STATUS current DESCRIPTION " Wait time for receiving calling party type (s) " DEFVAL { 50 } ::= { hwRegisterSignalAttributeEntry 12 } hwWaitBsignalTime OBJECT-TYPE SYNTAX Integer32(1..60) MAX-ACCESS read-write STATUS current DESCRIPTION " Wait time for receiving group B signal (s) " DEFVAL { 50 } ::= { hwRegisterSignalAttributeEntry 13 } hwNumberSendMode OBJECT-TYPE SYNTAX INTEGER{immediate(1),delay(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " Signal transmit mode Options: 1. immediate(1)- number send immediately 2. delay(2) - number send delay " DEFVAL { delay } ::= { hwRegisterSignalAttributeEntry 14 } hwCallingNumberMaxLength OBJECT-TYPE SYNTAX Integer32(0..32) MAX-ACCESS read-write STATUS current DESCRIPTION " Max. length of calling number " DEFVAL { 12 } ::= { hwRegisterSignalAttributeEntry 15 } hwCompellingSequenceKeepaliveTime OBJECT-TYPE SYNTAX Integer32(0..60000) MAX-ACCESS read-write STATUS current DESCRIPTION " Compelling sequence keepalive time for register signaling (ms) " DEFVAL { 40000 } ::= { hwRegisterSignalAttributeEntry 16 } hwSendPulseSignal OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " Whether to send sending-finished signals Options: 1. yes(1)- send pulse signal 2. no(2) - do not send pulse signal " DEFVAL { no } ::= { hwRegisterSignalAttributeEntry 17 } hwRegisterIncomingSignalType OBJECT-TYPE SYNTAX INTEGER{mfc(1),pulse(2),dtmf(3),mfp(4),dpmfp(5)} MAX-ACCESS read-write STATUS current DESCRIPTION " Signaling type of incoming office register Options: 1. mfc(1)-the register incoming signal type is mfc 2. pulse(2) -the register incoming signal type is pulse 3. dtmf(3) -the register incoming signal type is dtmf 4. mfp(4) -the register incoming signal type is mfp 5. dpmfp(5) -the register incoming signal type is dpmfp " DEFVAL { mfc } ::= { hwRegisterSignalAttributeEntry 18 } hwLineSignalAttributeTable OBJECT-TYPE SYNTAX SEQUENCE OF HwLineSignalAttributeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " R2 line signaling attribute table,this table is used to set and query r2 profile line signal attribute. The index of this table is hwLineSignalIndex " ::= { hwR2Objects 3 } hwLineSignalAttributeEntry OBJECT-TYPE SYNTAX HwLineSignalAttributeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " R2 line signaling attribute table,this table is used to set and query r2 profile line signal attribute. The index of this entry is hwLineSignalIndex " INDEX { hwLineSignalIndex } ::= { hwLineSignalAttributeTable 1 } HwLineSignalAttributeEntry ::= SEQUENCE { hwLineSignalIndex Integer32, hwLineSignalType INTEGER, hwWaitSeizeAckTime Integer32, hwWaitAnswerTime Integer32, hwWaitClearForwardTime Integer32, hwWaitProtectTime Integer32 } hwLineSignalIndex OBJECT-TYPE SYNTAX Integer32(0..15) MAX-ACCESS not-accessible STATUS current DESCRIPTION " R2 profile index " ::= { hwLineSignalAttributeEntry 1 } hwLineSignalType OBJECT-TYPE SYNTAX INTEGER{l1b(1),l2b(2),l3b(3),pulse(4)} MAX-ACCESS read-write STATUS obsolete DESCRIPTION " Line signaling type Options: 1. l1b(1)-line signal type is l1b 2. l2b(2) -line signal type is l2b 3. l3b(3) -line signal type is l3b 4. pulse(4) -line signal type is pulse " ::= { hwLineSignalAttributeEntry 2 } hwWaitSeizeAckTime OBJECT-TYPE SYNTAX Integer32(0..7000) MAX-ACCESS read-write STATUS current DESCRIPTION " Wait time for receiving occupation verification signal (ms) " DEFVAL { 5000 } ::= { hwLineSignalAttributeEntry 3 } hwWaitAnswerTime OBJECT-TYPE SYNTAX Integer32(0..511) MAX-ACCESS read-write STATUS current DESCRIPTION " Wait time for receiving answer signal (s) " DEFVAL { 300 } ::= { hwLineSignalAttributeEntry 4 } hwWaitClearForwardTime OBJECT-TYPE SYNTAX Integer32(0..2000) MAX-ACCESS read-write STATUS current DESCRIPTION " Wait time for receiving forward release signal (ms) " DEFVAL { 200 } ::= { hwLineSignalAttributeEntry 5 } hwWaitProtectTime OBJECT-TYPE SYNTAX Integer32(0..2000) MAX-ACCESS read-write STATUS current DESCRIPTION " Wait time for receiving release protection signal (ms) " DEFVAL { 200 } ::= { hwLineSignalAttributeEntry 6 } hwAddressSendListTable OBJECT-TYPE SYNTAX SEQUENCE OF HwAddressSendListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Attribute table for sent R2 address,this table is used to set and query register address send attribute. The index of this table is hwAddresssendInformationIndex " ::= { hwR2Objects 4 } hwAddressSendListEntry OBJECT-TYPE SYNTAX HwAddressSendListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Attribute table for sent R2 address,this table is used to set and query register address send attribute. The index of this entry is hwAddresssendInformationIndex " INDEX { hwAddresssendInformationIndex } ::= { hwAddressSendListTable 1 } HwAddressSendListEntry ::= SEQUENCE { hwAddresssendInformationIndex Integer32, hwAddressSendInformationDI INTEGER, hwAddressSendInformationSI INTEGER, hwAddressSendInformationSC INTEGER, hwAddressSendInformationES INTEGER, hwAddressSendInformationCC INTEGER, hwAddressSendInformationDISC INTEGER, hwAddressSendInformationNAC INTEGER, hwAddressSendInformationSP INTEGER } hwAddresssendInformationIndex OBJECT-TYPE SYNTAX Integer32(0..15) MAX-ACCESS not-accessible STATUS current DESCRIPTION " R2 profile index " ::= { hwAddressSendListEntry 1 } hwAddressSendInformationDI OBJECT-TYPE SYNTAX INTEGER{yes(1)} MAX-ACCESS read-only STATUS obsolete DESCRIPTION " Whether to send called numbers Options: 1. yes(1)-register signal address send callee number " ::= { hwAddressSendListEntry 2 } hwAddressSendInformationSI OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " Whether to send calling numbers Options: 1. yes(1)-register signal address send caller number 2. no(2)-register signal address does not send caller number " DEFVAL { yes } ::= { hwAddressSendListEntry 3 } hwAddressSendInformationSC OBJECT-TYPE SYNTAX INTEGER{yes(1)} MAX-ACCESS read-only STATUS obsolete DESCRIPTION " Whether to send calling party types Options: 1. yes(1)-register signal address send caller type " ::= { hwAddressSendListEntry 4 } hwAddressSendInformationES OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " Whether to send echo cancelation info Options: 1. yes(1)-register signal address send echo suppression 2. no(2)-register signal address does not send echo suppression " DEFVAL { no } ::= { hwAddressSendListEntry 5 } hwAddressSendInformationCC OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " Whether to send country code Options: 1. yes(1)-register signal address send country code 2. no(2)-register signal address does not send country code " DEFVAL { no } ::= { hwAddressSendListEntry 6 } hwAddressSendInformationDISC OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " Whether to send separating signaling Options: 1. yes(1)-register signal address send discrimination flag 2. no(2)-register signal address does not send discrimination flag " DEFVAL { no } ::= { hwAddressSendListEntry 7 } hwAddressSendInformationNAC OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " Whether to send circuit basic info Options: 1. yes(1)-register signal address send circuit character 2. no(2)-register signal address does not send circuit character " DEFVAL { no } ::= { hwAddressSendListEntry 8 } hwAddressSendInformationSP OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-only STATUS obsolete DESCRIPTION " Whether to send the calling priority Options: 1. yes(1)-register signal address send caller priority 2. no(2)-register signal address does not send caller priority " ::= { hwAddressSendListEntry 9 } hwAddressReceiveListTable OBJECT-TYPE SYNTAX SEQUENCE OF HwAddressReceiveListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Attribute table for received R2 address,this table is used to set and query register signal address receive attribute The index of this table is hwAddressReceiveInformationIndex " ::= { hwR2Objects 5 } hwAddressReceiveListEntry OBJECT-TYPE SYNTAX HwAddressReceiveListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Attribute table for received R2 address,this table is used to set and query register signal address receive attribute The index of this entry is hwAddressReceiveInformationIndex " INDEX { hwAddressReceiveInformationIndex } ::= { hwAddressReceiveListTable 1 } HwAddressReceiveListEntry ::= SEQUENCE { hwAddressReceiveInformationIndex Integer32, hwAddressReceiveInformationDI INTEGER, hwAddressReceiveInformationSI INTEGER, hwAddressReceiveInformationSC INTEGER, hwAddressReceiveInformationES INTEGER, hwAddressReceiveInformationCC INTEGER, hwAddressReceiveInformationDISC INTEGER, hwAddressReceiveInformationNAC INTEGER, hwAddressReceiveInformationSP INTEGER, hwRequestCallerLineNoPosition Integer32, hwRequestCallerLineTypePosition Integer32 } hwAddressReceiveInformationIndex OBJECT-TYPE SYNTAX Integer32(0..15) MAX-ACCESS not-accessible STATUS current DESCRIPTION " R2 profile index " ::= { hwAddressReceiveListEntry 1 } hwAddressReceiveInformationDI OBJECT-TYPE SYNTAX INTEGER{yes(1)} MAX-ACCESS read-only STATUS obsolete DESCRIPTION " Whether to receive called numbers Options: 1. yes(1)-register signal address receive callee number " ::= { hwAddressReceiveListEntry 2 } hwAddressReceiveInformationSI OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " Whether to receive calling numbers Options: 1. yes(1)-register signal address receive calling number 2. no(2)-register signal address does not receive calling number " DEFVAL { yes } ::= { hwAddressReceiveListEntry 3 } hwAddressReceiveInformationSC OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " Whether to receive calling party types Options: 1. yes(1)-register signal address receive calling user type 2. no(2)-register signal address does not receive calling user type " DEFVAL { yes } ::= { hwAddressReceiveListEntry 4 } hwAddressReceiveInformationES OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " Whether to receive echo cancelation info Options: 1. yes(1)-register signal address receive echo suppression 2. no(2)-register signal address does not receive echo suppression " DEFVAL { no } ::= { hwAddressReceiveListEntry 5 } hwAddressReceiveInformationCC OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " Whether to receive country code Options: 1. yes(1)-register signal address receive country code 2. no(2)-register signal address does not receive country code " DEFVAL { no } ::= { hwAddressReceiveListEntry 6 } hwAddressReceiveInformationDISC OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " Whether to receive separating signaling Options: 1. yes(1)-register signal address receive distinctive indication 2. no(2)-register signal address does not receive distinctive indication " DEFVAL { no } ::= { hwAddressReceiveListEntry 7 } hwAddressReceiveInformationNAC OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " Whether to receive circuit basic info Options: 1. yes(1)-register signal address receive circuit character 2. no(2)-register signal address does not receive circuit character " DEFVAL { no } ::= { hwAddressReceiveListEntry 8 } hwAddressReceiveInformationSP OBJECT-TYPE SYNTAX INTEGER{yes(1),no(2)} MAX-ACCESS read-only STATUS obsolete DESCRIPTION " Whether to receive calling priority Options: 1. yes(1)-register signal address receive caller priority 2. no(2)-register signal address does not receive caller priority " ::= { hwAddressReceiveListEntry 9 } hwRequestCallerLineNoPosition OBJECT-TYPE SYNTAX Integer32(1..12) MAX-ACCESS read-write STATUS current DESCRIPTION " Called number digits before requesting calling number (The calling number must be requested after the calling party type.) " DEFVAL { 1 } ::= { hwAddressReceiveListEntry 10 } hwRequestCallerLineTypePosition OBJECT-TYPE SYNTAX Integer32(1..12) MAX-ACCESS read-write STATUS current DESCRIPTION " Called number digits before requesting calling party type (The calling party type must be requested before the calling number.) " DEFVAL { 1 } ::= { hwAddressReceiveListEntry 11 } hwR2SignalTypeVersionTable OBJECT IDENTIFIER ::={ hwR2Objects 6 } hwSignalTypeVersion OBJECT-TYPE SYNTAX OCTET STRING(SIZE (1..10)) MAX-ACCESS read-only STATUS current DESCRIPTION " Version of R2 signaling type file " ::= { hwR2SignalTypeVersionTable 1 } hwR2SignalTypeTable OBJECT-TYPE SYNTAX SEQUENCE OF HwR2SignalTypeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " R2 signaling type table,this table is used to query R2 signal type information The index of this table is hwSignalTypeIndex " ::= { hwR2Objects 7 } hwR2SignalTypeEntry OBJECT-TYPE SYNTAX HwR2SignalTypeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " R2 signaling type table,this table is used to query R2 signal type information The index of this entry is hwSignalTypeIndex " INDEX { hwSignalTypeIndex } ::= { hwR2SignalTypeTable 1 } HwR2SignalTypeEntry ::= SEQUENCE { hwSignalTypeIndex Integer32, hwSignalTypeName OCTET STRING } hwSignalTypeIndex OBJECT-TYPE SYNTAX Integer32(0..15) MAX-ACCESS not-accessible STATUS current DESCRIPTION " R2 signaling type index " ::= { hwR2SignalTypeEntry 1 } hwSignalTypeName OBJECT-TYPE SYNTAX OCTET STRING(SIZE (0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION " R2 signaling type name The names of the preconfigured multiple countries adaption profiles with IDs ranging from 0 to 9 cannot be modified " ::= { hwR2SignalTypeEntry 2 } END