-- =========================================================== -- Copyright (C) 2021 by HUAWEI TECHNOLOGIES. All rights reserved. -- -- Description: HUAWEI POE MIB Definition -- Reference: This mib was extracted from IEEE 802.3af -- Version: V1.17 -- History: Liuhui ,2009-08-24, Create -- =========================================================== HUAWEI-POE-MIB DEFINITIONS ::= BEGIN IMPORTS hwDatacomm FROM HUAWEI-MIB InterfaceIndex FROM IF-MIB EnabledStatus FROM P-BRIDGE-MIB TruthValue FROM SNMPv2-TC OBJECT-GROUP, MODULE-COMPLIANCE,NOTIFICATION-GROUP FROM SNMPv2-CONF Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI; hwPoeMIB MODULE-IDENTITY LAST-UPDATED "202108120000Z" -- Aug 12, 2021 at 00:00 GMT ORGANIZATION "Huawei Technologies Co.,Ltd." CONTACT-INFO "Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com Email: support@huawei.com " DESCRIPTION "The HUAWEI-POE-MIB contains objects to manage POE." REVISION "202108120000Z" DESCRIPTION "V1.17, Add hwPoeCommunicateFail and hwPoeCardAbsent " REVISION "202105080000Z" DESCRIPTION "V1.16, Modity hwPoePowerOff " REVISION "201901030000Z" DESCRIPTION "V1.15, Add hwPoePdOvercurrentPoweroff and hwPoePdOverloadPoweroff " REVISION "201810180000Z" DESCRIPTION "V1.134 Modify the range of hwPoeSlotMaximumPower" REVISION "201805160000Z" DESCRIPTION "V1.13, Add hwPoeMultiMcuTable and hwPoeSlotMcuSupport" REVISION "201803080000Z" DESCRIPTION "V1.12, Add NOTIFICATION-TYPE" REVISION "201612020000Z" DESCRIPTION "V1.11, Add hwPoePortFail and hwPoePortFailResume" REVISION "201609190000Z" DESCRIPTION "V1.10, Change hwPoePortPdClass properties" REVISION "201509280000Z" DESCRIPTION "V1.09, Add hwPoePortLegacyDetect " REVISION "201508100000Z" DESCRIPTION "V1.03, Add hwPoeCardAbsent " REVISION "201504020000Z" DESCRIPTION "V1.02, Add hwPoeNotAvailable and hwPoeNotAvailableResume " REVISION "201502250000Z" DESCRIPTION "V1.06, Add hwPoePortMaxPowerThreshold,hwPoePortMinPowerThreshold " REVISION "201311120000Z" DESCRIPTION "V1.05, Add hwPoePowerInfoTable " REVISION "201310220000Z" DESCRIPTION "V1.04, Change the maximum power to 200000 " REVISION "201307160000Z" DESCRIPTION "V1.03, Add hwPoePortPoweroffTimeRangeSwitch and hwPoePortPoweroffTimeRangeName " REVISION "201304240000Z" DESCRIPTION "V1.02, Add hwPoePSEPowerCut,hwPoePSEPowerCutResume,hwPoeSlotPowerCut,hwPoeSlotPowerCutResume " REVISION "201303130000Z" DESCRIPTION "V1.01, Add hwPoeControlChipFail and hwPoeControlChipFailResume " ::= { hwDatacomm 195 } -- -- Node definitions -- hwPoeGlobalObjects OBJECT IDENTIFIER ::= { hwPoeMIB 1 } hwPoePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the maximum POE power of the system." ::= { hwPoeGlobalObjects 1 } hwPoePowerRsvPercent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the reserved percent of total POE power." ::= { hwPoeGlobalObjects 4 } hwPoePowerUtilizationThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the utilization threshold of total POE power." ::= { hwPoeGlobalObjects 5 } hwPoeSlotTable OBJECT-TYPE SYNTAX SEQUENCE OF HwPoeSlotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the slot configuration table of POE." ::= { hwPoeMIB 2 } hwPoeSlotEntry OBJECT-TYPE SYNTAX HwPoeSlotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the entry of the slot configuration table of POE." INDEX { hwPoeSlotId } ::= { hwPoeSlotTable 1 } HwPoeSlotEntry ::= SEQUENCE { hwPoeSlotId Integer32, hwPoeSlotMaximumPower Integer32, hwPoeSlotAvailablePower Integer32, hwPoeSlotReferencePower Integer32, hwPoeSlotConsumingPower Integer32, hwPoeSlotPeakPower Integer32, hwPoeSlotLegacyDetect EnabledStatus, hwPoeSlotPowerManagementManner INTEGER, hwPoeSlotIsPoeDevice OCTET STRING, hwPoeDimmId Integer32, hwPoeSlotPowerRsvPercent Integer32, hwPoeSlotPowerUtilizationThreshold Integer32, hwPoeSlotMcuSupport Integer32 } hwPoeSlotId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the slot ID." ::= { hwPoeSlotEntry 1 } hwPoeSlotMaximumPower OBJECT-TYPE SYNTAX Integer32 (0..7200000) UNITS "mW" MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the maximum power set by users. The value is expressed in mW." DEFVAL { '1B1980'h } ::= { hwPoeSlotEntry 2 } hwPoeSlotAvailablePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object idenfies the available Power. The value is expressed in mW." ::= { hwPoeSlotEntry 3 } hwPoeSlotReferencePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the total reference power of a slot. The value is expressed in mW." ::= { hwPoeSlotEntry 4 } hwPoeSlotConsumingPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the total consuming power of a slot. The value is expressed in mW." ::= { hwPoeSlotEntry 5 } hwPoeSlotPeakPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the total peak power of a slot. The value is expressed in mW." ::= { hwPoeSlotEntry 6 } hwPoeSlotLegacyDetect OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the compatibility detection of a non-standard device. (1:enable; 2:disable(default))" DEFVAL { disabled } ::= { hwPoeSlotEntry 7 } hwPoeSlotPowerManagementManner OBJECT-TYPE SYNTAX INTEGER { manual(1), auto(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the power management manner. (1:manual, 2:auto(default))." DEFVAL { auto } ::= { hwPoeSlotEntry 8 } hwPoeSlotIsPoeDevice OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates whether the device supports PoE." ::= { hwPoeSlotEntry 9 } hwPoeDimmId OBJECT-TYPE SYNTAX Integer32 (0..1) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object identifies the DIMM ID." ::= { hwPoeSlotEntry 10 } hwPoeSlotPowerRsvPercent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the reserved percent of POE power in slot." ::= { hwPoeSlotEntry 11 } hwPoeSlotPowerUtilizationThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the utilization threshold of total POE power in slot." ::= { hwPoeSlotEntry 12 } hwPoeSlotMcuSupport OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the mcu chip number of a POE slot." ::= { hwPoeSlotEntry 13 } hwPoePortTable OBJECT-TYPE SYNTAX SEQUENCE OF HwPoePortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the table that contains the configuration parameters of a POE interface. One entry corresponds to a POE interface." ::= { hwPoeMIB 3 } hwPoePortEntry OBJECT-TYPE SYNTAX HwPoePortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the entry of POE Port Table." INDEX { hwPoePortIfIndex } ::= { hwPoePortTable 1 } HwPoePortEntry ::= SEQUENCE { hwPoePortIfIndex InterfaceIndex, hwPoePortName OCTET STRING, hwPoePortEnable EnabledStatus, hwPoePortPriority INTEGER, hwPoePortMaximumPower Integer32, hwPoePortPowerOnStatus OCTET STRING, hwPoePortPowerStatus OCTET STRING, hwPoePortPdClass Integer32, hwPoePortReferencePower Integer32, hwPoePortConsumingPower Integer32, hwPoePortPeakPower Integer32, hwPoePortAveragePower Integer32, hwPoePortCurrent OCTET STRING, hwPoePortVoltage OCTET STRING, hwPoePortManualOperation INTEGER, hwPoePortPoweroffTimeRangeSwitch EnabledStatus, hwPoePortPoweroffTimeRangeName OCTET STRING, hwPoePortMaxPowerThreshold Integer32, hwPoePortMinPowerThreshold Integer32, hwPoePortLegacyDetect EnabledStatus } hwPoePortIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the interface index." ::= { hwPoePortEntry 1 } hwPoePortName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the interface name." ::= { hwPoePortEntry 2 } hwPoePortEnable OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the enabling status of an interface. (1:enable(default); 2:disable)" DEFVAL { enabled } ::= { hwPoePortEntry 3 } hwPoePortPriority OBJECT-TYPE SYNTAX INTEGER { critical(1), high(2), low(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the priority of an interface. (1:critical, 2:high, 3:low(default))" DEFVAL { low } ::= { hwPoePortEntry 4 } hwPoePortMaximumPower OBJECT-TYPE SYNTAX Integer32 (0..200000) UNITS "mW" MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the maximum power of an interface.The value is expressed in mW." DEFVAL { '9088'h } ::= { hwPoePortEntry 5 } hwPoePortPowerOnStatus OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the powering status of an interface." ::= { hwPoePortEntry 6 } hwPoePortPowerStatus OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the status of an interface." ::= { hwPoePortEntry 7 } hwPoePortPdClass OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the class of a PD." ::= { hwPoePortEntry 8 } hwPoePortReferencePower OBJECT-TYPE SYNTAX Integer32 (0..200000) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the guaranteed power of an interface. The value is expressed in mW." ::= { hwPoePortEntry 9 } hwPoePortConsumingPower OBJECT-TYPE SYNTAX Integer32 (0..200000) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the consuming power of an interface. The value is expressed in mW." ::= { hwPoePortEntry 10 } hwPoePortPeakPower OBJECT-TYPE SYNTAX Integer32 (0..200000) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the peak power of an interface. The value is expressed in mW." ::= { hwPoePortEntry 11 } hwPoePortAveragePower OBJECT-TYPE SYNTAX Integer32 (0..200000) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the average power of an interface. The value is expressed in mW." ::= { hwPoePortEntry 12 } hwPoePortCurrent OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the current of an interface. The value is expressed in mA." ::= { hwPoePortEntry 13 } hwPoePortVoltage OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the voltage of an interface. The value is expressed in V." ::= { hwPoePortEntry 14 } hwPoePortManualOperation OBJECT-TYPE SYNTAX INTEGER { powerOff(1), powerOn(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates that a PD connected to an interface is powered on or powered off manually." ::= { hwPoePortEntry 15 } hwPoePortPoweroffTimeRangeSwitch OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the time range of POE power off is configured on the port." ::= { hwPoePortEntry 16 } hwPoePortPoweroffTimeRangeName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates that time range name of POE power off configured on the port." ::= { hwPoePortEntry 17 } hwPoePortMaxPowerThreshold OBJECT-TYPE SYNTAX Integer32 (0..200000) UNITS "mW" MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the threshold of the available maximum power of an interface. The value is expressed in mW." DEFVAL { '9088'h } ::= { hwPoePortEntry 18 } hwPoePortMinPowerThreshold OBJECT-TYPE SYNTAX Integer32 (0..200000) UNITS "mW" MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the threshold of the available minimum power of an interface. The value is expressed in mW." DEFVAL { '9088'h } ::= { hwPoePortEntry 19 } hwPoePortLegacyDetect OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the compatibility detection of a non-standard device. (1:enable; 2:disable(default))" DEFVAL { disabled } ::= { hwPoePortEntry 20 } hwPoePortJudgeTable OBJECT-TYPE SYNTAX SEQUENCE OF HwPoePortJudgeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the table that contains the judgement of whether port supports POE." ::= { hwPoeMIB 4 } hwPoePortJudgeEntry OBJECT-TYPE SYNTAX HwPoePortJudgeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the entry of table." INDEX { hwPoePortJudgeIfIndex } ::= { hwPoePortJudgeTable 1 } HwPoePortJudgeEntry ::= SEQUENCE { hwPoePortJudgeIfIndex InterfaceIndex, hwPoePortJudgeIsSupport TruthValue } hwPoePortJudgeIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the interface index." ::= { hwPoePortJudgeEntry 1 } hwPoePortJudgeIsSupport OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates whether the interface supports POE." ::= { hwPoePortJudgeEntry 2 } hwPoePowerInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HwPoePowerInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the table that contains the power information of POE." ::= { hwPoeMIB 5 } hwPoePowerInfoEntry OBJECT-TYPE SYNTAX HwPoePowerInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the entry of table." INDEX { hwPoePowerInfoDeviceIndex } ::= { hwPoePowerInfoTable 1 } HwPoePowerInfoEntry ::= SEQUENCE { hwPoePowerInfoDeviceIndex Integer32, hwPoePowerInfoDeviceName OCTET STRING, hwPoePowerInfoDeviceTotalPower Integer32, hwPoePowerInfoDeviceTotalAvailablePower Integer32, hwPoePowerInfoDeviceReservedPower Integer32, hwPoePowerInfoDeviceUsedPower Integer32, hwPoePowerInfoDeviceRemainPower Integer32 } hwPoePowerInfoDeviceIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the device index. Index: reserved/chassis/slot. The index is format by 4 bytes(8bits for 1 byte): reserved is 1 byte(0x00), chassis is 12bits and slot is also 12bits. e.g. chassis=1, slot=0, the index is 0x00001000. If device is chassis, the slot is always 0. If device is box, the chassis is always 0." ::= { hwPoePowerInfoEntry 1 } hwPoePowerInfoDeviceName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the table that contains the name of device." ::= { hwPoePowerInfoEntry 2 } hwPoePowerInfoDeviceTotalPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the table that contains the total power of POE." ::= { hwPoePowerInfoEntry 3 } hwPoePowerInfoDeviceTotalAvailablePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the table that contains the total available power of POE." ::= { hwPoePowerInfoEntry 4 } hwPoePowerInfoDeviceReservedPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the table that contains the reserved power of POE." ::= { hwPoePowerInfoEntry 5 } hwPoePowerInfoDeviceUsedPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the table that contains the used power of POE." ::= { hwPoePowerInfoEntry 6 } hwPoePowerInfoDeviceRemainPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the table that contains the remain power of POE." ::= { hwPoePowerInfoEntry 7 } hwPoeMultiMcuTable OBJECT-TYPE SYNTAX SEQUENCE OF HwPoeMultiMcuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the slot configuration table of multi-mcu POE." ::= { hwPoeMIB 6 } hwPoeMultiMcuEntry OBJECT-TYPE SYNTAX HwPoeMultiMcuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the entry of the slot configuration table of multi-mcu POE." INDEX { hwPoeMultiMcuSlotId, hwPoeMultiMcuMcuIndex } ::= { hwPoeMultiMcuTable 1 } HwPoeMultiMcuEntry ::= SEQUENCE { hwPoeMultiMcuSlotId Integer32, hwPoeMultiMcuMcuIndex Integer32, hwPoeMultiMcuMaximumPower Integer32, hwPoeMultiMcuAvailablePower Integer32, hwPoeMultiMcuPowerRcvPercent Integer32, hwPoeMultiPowerUtilizationThreshold Integer32 } hwPoeMultiMcuSlotId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the slot ID." ::= { hwPoeMultiMcuEntry 1 } hwPoeMultiMcuMcuIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the mcu ID." ::= { hwPoeMultiMcuEntry 2 } hwPoeMultiMcuMaximumPower OBJECT-TYPE SYNTAX Integer32 (0..1776000) UNITS "mW" MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the maximum power set by users in slot and mcu. The value is expressed in mW." DEFVAL { '1B1980'h } ::= { hwPoeMultiMcuEntry 3 } hwPoeMultiMcuAvailablePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object idenfies the available power in slot and mcu. The value is expressed in mW." ::= { hwPoeMultiMcuEntry 4 } hwPoeMultiMcuPowerRcvPercent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the reserved percent of POE power in slot and mcu." ::= { hwPoeMultiMcuEntry 5 } hwPoeMultiPowerUtilizationThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the utilization threshold of total POE power in slot and mcu." ::= { hwPoeMultiMcuEntry 6 } hwPoeTrapObjects OBJECT IDENTIFIER ::= { hwPoeMIB 39 } hwPoePdPriority OBJECT-TYPE SYNTAX INTEGER { critical(1), high(2), low(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object identifies the PD priority.(1:critical, 2:high, 3:low(default))" ::= { hwPoeTrapObjects 1 } hwPoeSlotNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object identifies the slot ID." ::= { hwPoeTrapObjects 2 } hwPoeCurConsumPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object identifies the current consuming power." ::= { hwPoeTrapObjects 3 } hwPoeConsumPowerThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object identifies the threshold of consuming power." ::= { hwPoeTrapObjects 4 } hwPoeDeviceID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object identifies the device ID." ::= { hwPoeTrapObjects 5 } hwFrameID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object identifies the CSS Frame ID." ::= { hwPoeTrapObjects 6 } hwPoeChipID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object identifies the control chip ID." ::= { hwPoeTrapObjects 7 } hwTrapProbableCause OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The probable cause of poe trap." ::= { hwPoeTrapObjects 8 } hwPoeCardID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object identifies the poe card ID." ::= { hwPoeTrapObjects 9 } hwPoeSlotStr OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object identifies the poe card String." ::= { hwPoeTrapObjects 10 } hwPoeTrapFaultID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The probable fault id of poe trap." ::= { hwPoeTrapObjects 11 } hwPoeNotification OBJECT IDENTIFIER ::= { hwPoeMIB 40 } hwPoeDimmError NOTIFICATION-TYPE OBJECTS { hwPoeSlotNum, hwPoeDimmId } STATUS current DESCRIPTION "This object indicates the Dimm chip error." ::= { hwPoeNotification 1 } hwPoePowerOff NOTIFICATION-TYPE OBJECTS { hwPoePortName, hwPoeTrapFaultID } STATUS current DESCRIPTION "This object indicates a PD connected to an interface is powered off." ::= { hwPoeNotification 2 } hwPoePowerOn NOTIFICATION-TYPE OBJECTS { hwPoePortName } STATUS current DESCRIPTION "This object indicates that a PD connected to an interface is powered on." ::= { hwPoeNotification 3 } hwPoeSlotPowerOverload NOTIFICATION-TYPE OBJECTS { hwPoeSlotNum, hwPoeSlotConsumingPower } STATUS current DESCRIPTION "This object indicates that the power consumed by a slot exceeds the threshold." ::= { hwPoeNotification 4 } hwPoeSlotPowerOverloadResume NOTIFICATION-TYPE OBJECTS { hwPoeSlotNum, hwPoeSlotConsumingPower } STATUS current DESCRIPTION "This object indicates that the power consumed by a slot does not exceed the threshold." ::= { hwPoeNotification 5 } hwPoePdPowerOverload NOTIFICATION-TYPE OBJECTS { hwPoePortName, hwPoePortConsumingPower, hwPoePortMaximumPower } STATUS current DESCRIPTION "This object indicates the power consumed by a PD connected to an interface exceeds the threshold." ::= { hwPoeNotification 6 } hwPoePdPowerOverloadResume NOTIFICATION-TYPE OBJECTS { hwPoePortName, hwPoePortConsumingPower, hwPoePortMaximumPower } STATUS current DESCRIPTION "This object indicates that the power consumed by a PD connected to an interface does not exceed the threshold." ::= { hwPoeNotification 7 } hwPoePdConnected NOTIFICATION-TYPE OBJECTS { hwPoePortName } STATUS current DESCRIPTION "This object indicates that a PD is connected to an interface." ::= { hwPoeNotification 8 } hwPoePdDisconnected NOTIFICATION-TYPE OBJECTS { hwPoePortName } STATUS current DESCRIPTION "This object indicates that a PD is disconnected from an interface." ::= { hwPoeNotification 9 } hwPoePdClassInvalid NOTIFICATION-TYPE OBJECTS { hwPoePortName } STATUS current DESCRIPTION "This object indicates that a PD of an invalid class is detected." ::= { hwPoeNotification 10 } hwPoePdClassOvercurrent NOTIFICATION-TYPE OBJECTS { hwPoePortName } STATUS current DESCRIPTION "This object indicates that overcurrent occurs during the classification of a PD." ::= { hwPoeNotification 11 } hwPoePdPowerOvercurrent NOTIFICATION-TYPE OBJECTS { hwPoePortName } STATUS current DESCRIPTION "This object indicates that overcurrent occurs during the powering of a PD." ::= { hwPoeNotification 12 } hwPoePdPowerOvercurrentResume NOTIFICATION-TYPE OBJECTS { hwPoePortName } STATUS current DESCRIPTION "This object indicates that overcurrent is rectified." ::= { hwPoeNotification 13 } hwPoePowerOnFail NOTIFICATION-TYPE OBJECTS { hwPoePortName } STATUS current DESCRIPTION "This object indicates that a PD fails to be powered on." ::= { hwPoeNotification 14 } hwPoePowerOffCurrentLimits NOTIFICATION-TYPE OBJECTS { hwPoePortName } STATUS current DESCRIPTION "This object indicates that a PD is powered off because its current meets or exceeds the limit of current." ::= { hwPoeNotification 15 } hwPoePdPriorityDifferent NOTIFICATION-TYPE OBJECTS { hwPoePortName, hwPoePortPriority, hwPoePdPriority } STATUS current DESCRIPTION "This object indicates that the priority of PD is different from the port." ::= { hwPoeNotification 16 } hwPoePowerOverUtilizationThreshold NOTIFICATION-TYPE OBJECTS { hwPoeDeviceID, hwPoeCurConsumPower, hwPoeConsumPowerThreshold} STATUS current DESCRIPTION "This object indicates that the PSE is overdrawing power." ::= { hwPoeNotification 17 } hwPoePowerOverUtilizationThresholdResume NOTIFICATION-TYPE OBJECTS { hwPoeDeviceID, hwPoeCurConsumPower, hwPoeConsumPowerThreshold} STATUS current DESCRIPTION "This object indicates that the PSE is not overdrawing power." ::= { hwPoeNotification 18 } hwPoeBoardInsertedWrongFrame NOTIFICATION-TYPE OBJECTS {hwFrameID, hwPoeSlotNum } STATUS current DESCRIPTION "This object indicates that the poe board is inserted in the frame does not support poe." ::= { hwPoeNotification 19 } hwPoePowerAbsent NOTIFICATION-TYPE OBJECTS {hwFrameID, hwPoeSlotNum } STATUS current DESCRIPTION "This object indicates that the poe power is absent." ::= { hwPoeNotification 20 } hwPoePowerAbsentResume NOTIFICATION-TYPE OBJECTS {hwFrameID, hwPoeSlotNum } STATUS current DESCRIPTION "This object indicates that the poe power is present." ::= { hwPoeNotification 21 } hwPoeRpsPowerOutputAlarm NOTIFICATION-TYPE OBJECTS {hwPoeSlotNum } STATUS current DESCRIPTION "This object indicates that the RPS power can not provide POE power for this device." ::= { hwPoeNotification 22 } hwPoeRpsPowerOutputAlarmResume NOTIFICATION-TYPE OBJECTS {hwPoeSlotNum } STATUS current DESCRIPTION "This object indicates that the RPS power can provide POE power for this device." ::= { hwPoeNotification 23 } hwPoeControlChipFail NOTIFICATION-TYPE OBJECTS {hwPoeChipID,hwPoeSlotNum } STATUS current DESCRIPTION "This object indicates that the poe control chip is failed." ::= { hwPoeNotification 24 } hwPoeControlChipFailResume NOTIFICATION-TYPE OBJECTS {hwPoeChipID,hwPoeSlotNum } STATUS current DESCRIPTION "This object indicates that the poe control chip has resumed." ::= { hwPoeNotification 25 } hwPoePSEPowerCut NOTIFICATION-TYPE STATUS current DESCRIPTION "This object indicates that the poe pse power is not enough." ::= { hwPoeNotification 26 } hwPoePSEPowerCutResume NOTIFICATION-TYPE STATUS current DESCRIPTION "This object indicates that the poe pse power cut has resumed." ::= { hwPoeNotification 27 } hwPoeSlotPowerCut NOTIFICATION-TYPE OBJECTS {hwPoeSlotNum} STATUS current DESCRIPTION "This object indicates that the poe slot power is not enough." ::= { hwPoeNotification 28 } hwPoeSlotPowerCutResume NOTIFICATION-TYPE OBJECTS {hwPoeSlotNum} STATUS current DESCRIPTION "This object indicates that the poe slot power cut has resumed." ::= { hwPoeNotification 29 } hwPoeNotAvailable NOTIFICATION-TYPE OBJECTS {hwFrameID,hwPoeSlotNum,hwTrapProbableCause} STATUS current DESCRIPTION "PoE function is not available." ::= { hwPoeNotification 30 } hwPoeNotAvailableResume NOTIFICATION-TYPE OBJECTS {hwFrameID,hwPoeSlotNum} STATUS current DESCRIPTION "PoE function is available." ::= { hwPoeNotification 31 } hwPoeCardAbsent NOTIFICATION-TYPE OBJECTS {hwPoeSlotNum,hwPoeCardID} STATUS current DESCRIPTION "This object indicates that the poe card is absent." ::= { hwPoeNotification 32 } hwPoePortFail NOTIFICATION-TYPE OBJECTS {hwPoePortName} STATUS current DESCRIPTION "This object indicates that the poe port is abnormal." ::= { hwPoeNotification 33 } hwPoePortFailResume NOTIFICATION-TYPE OBJECTS {hwPoePortName} STATUS current DESCRIPTION "This object indicates that the poe port has recoverd." ::= { hwPoeNotification 34 } hwPdPowerCut NOTIFICATION-TYPE OBJECTS {hwPoePortName,hwPoeTrapFaultID} STATUS current DESCRIPTION "PoE power is not enough." ::= { hwPoeNotification 35 } hwPdPowerCutResume NOTIFICATION-TYPE OBJECTS {hwPoePortName,hwPoeTrapFaultID} STATUS current DESCRIPTION "PoE power is enough." ::= { hwPoeNotification 36 } hwPoeChipFail NOTIFICATION-TYPE OBJECTS {hwPoeChipID,hwPoeSlotStr} STATUS current DESCRIPTION "This object indicates that the poe chip is failed." ::= { hwPoeNotification 37 } hwPoeChipFailResume NOTIFICATION-TYPE OBJECTS {hwPoeChipID,hwPoeSlotStr} STATUS current DESCRIPTION "This object indicates that the poe chip has resumed." ::= { hwPoeNotification 38 } hwPdVltLow NOTIFICATION-TYPE OBJECTS {hwPoePortName} STATUS current DESCRIPTION "PD voltage is lower." ::= { hwPoeNotification 39 } hwPdVltLowResume NOTIFICATION-TYPE OBJECTS {hwPoePortName} STATUS current DESCRIPTION "PD voltage becomes normal from lower." ::= { hwPoeNotification 40 } hwPdVltHigh NOTIFICATION-TYPE OBJECTS {hwPoePortName} STATUS current DESCRIPTION "PD voltage is high." ::= { hwPoeNotification 41 } hwPdVltHighResume NOTIFICATION-TYPE OBJECTS {hwPoePortName} STATUS current DESCRIPTION "PD voltage becomes normal from high." ::= { hwPoeNotification 42 } hwPseVltLow NOTIFICATION-TYPE OBJECTS {hwPoeChipID,hwPoeSlotStr} STATUS current DESCRIPTION "PSE voltage is lower." ::= { hwPoeNotification 43 } hwPseVltLowResume NOTIFICATION-TYPE OBJECTS {hwPoeChipID,hwPoeSlotStr} STATUS current DESCRIPTION "PSE voltage becomes normal from lower." ::= { hwPoeNotification 44 } hwPoePdOvercurrentPoweroff NOTIFICATION-TYPE OBJECTS { hwPoePortName } STATUS current DESCRIPTION "This object indicates that the PD is power off due to overcurrent." ::= { hwPoeNotification 45 } hwPoePdOverloadPoweroff NOTIFICATION-TYPE OBJECTS { hwPoePortName } STATUS current DESCRIPTION "This object indicates that the PD is power off due to overload." ::= { hwPoeNotification 46 } hwPoeSubCardAbsent NOTIFICATION-TYPE OBJECTS {hwPoeCardID,hwPoeSlotStr} STATUS current DESCRIPTION "This object indicates that the poe subcard is absent." ::= { hwPoeNotification 47 } hwPoeSubCardAbsentResume NOTIFICATION-TYPE OBJECTS {hwPoeCardID,hwPoeSlotStr} STATUS current DESCRIPTION "This object indicates that the poe subcard is re-installed." ::= { hwPoeNotification 48 } hwPoeCommunicateFail NOTIFICATION-TYPE OBJECTS {hwPoeChipID,hwPoeSlotStr} STATUS current DESCRIPTION "This object indicates that the poe communication fails." ::= { hwPoeNotification 49 } hwPoeCommunicateFailResume NOTIFICATION-TYPE OBJECTS {hwPoeChipID,hwPoeSlotStr} STATUS current DESCRIPTION "This object indicates that the poe communication has resumed." ::= { hwPoeNotification 50 } hwPoeConformance OBJECT IDENTIFIER ::= { hwPoeMIB 100 } hwPoeCompliances OBJECT IDENTIFIER ::= { hwPoeConformance 1 } hwPoeCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for systems supporting this module." MODULE MANDATORY-GROUPS { hwPoeSlotGroup, hwPoePortGroup, hwPoeGlobalGroup, hwPoeNotificationGroup, hwPoeTrapObjectsGroup, hwPoePowerInfoGroup } ::= { hwPoeCompliances 1 } hwPoeGroups OBJECT IDENTIFIER ::= { hwPoeConformance 2 } hwPoeSlotGroup OBJECT-GROUP OBJECTS { hwPoeSlotMaximumPower, hwPoeSlotReferencePower, hwPoeSlotConsumingPower, hwPoeSlotPeakPower, hwPoeSlotPowerManagementManner, hwPoeSlotIsPoeDevice, hwPoeSlotLegacyDetect, hwPoeSlotPowerRsvPercent, hwPoeSlotPowerUtilizationThreshold, hwPoeSlotMcuSupport, hwPoeDimmId, hwPoeSlotAvailablePower } STATUS current DESCRIPTION "This object indicates the POE's slot table group." ::= { hwPoeGroups 1 } hwPoePortGroup OBJECT-GROUP OBJECTS { hwPoePortEnable, hwPoePortPriority, hwPoePortMaximumPower, hwPoePortPowerOnStatus, hwPoePortPowerStatus, hwPoePortReferencePower, hwPoePortName, hwPoePortConsumingPower, hwPoePortPeakPower, hwPoePortAveragePower, hwPoePortCurrent, hwPoePortVoltage, hwPoePortManualOperation, hwPoePortPdClass,hwPoePortJudgeIsSupport, hwPoePortPoweroffTimeRangeSwitch, hwPoePortPoweroffTimeRangeName, hwPoePortMaxPowerThreshold, hwPoePortMinPowerThreshold, hwPoePortLegacyDetect} STATUS current DESCRIPTION "This object indicates the POE's port table group." ::= { hwPoeGroups 2 } hwPoeGlobalGroup OBJECT-GROUP OBJECTS { hwPoePowerUtilizationThreshold, hwPoePowerRsvPercent, hwPoePower } STATUS current DESCRIPTION "This object indicates the POE's global table group." ::= { hwPoeGroups 3 } hwPoeNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { hwPoeDimmError, hwPoePowerOff, hwPoePowerOn, hwPoePdPowerOverload, hwPoePdPowerOverloadResume, hwPoePdConnected, hwPoePdDisconnected, hwPoePdClassInvalid, hwPoePdClassOvercurrent, hwPoePdPowerOvercurrent, hwPoePdPowerOvercurrentResume, hwPoePowerOnFail, hwPoePowerOffCurrentLimits, hwPoePowerOverUtilizationThresholdResume , hwPoePowerOverUtilizationThreshold , hwPoePdPriorityDifferent, hwPoeSlotPowerOverload, hwPoeSlotPowerOverloadResume , hwPoeBoardInsertedWrongFrame ,hwPoePowerAbsent,hwPoePowerAbsentResume, hwPoeRpsPowerOutputAlarm, hwPoeRpsPowerOutputAlarmResume, hwPoeControlChipFail, hwPoeControlChipFailResume, hwPoePSEPowerCut,hwPoePSEPowerCutResume,hwPoeSlotPowerCut,hwPoeSlotPowerCutResume, hwPoeNotAvailable,hwPoeNotAvailableResume,hwPoeCardAbsent,hwPoePortFail,hwPoePortFailResume, hwPdPowerCut,hwPdPowerCutResume,hwPoeChipFail,hwPoeChipFailResume,hwPdVltLow,hwPdVltLowResume, hwPdVltHigh,hwPdVltHighResume,hwPseVltLow,hwPseVltLowResume,hwPoePdOvercurrentPoweroff,hwPoePdOverloadPoweroff, hwPoeSubCardAbsent,hwPoeSubCardAbsentResume,hwPoeCommunicateFail,hwPoeCommunicateFailResume} STATUS current DESCRIPTION "This object indicates the POE's notification table group." ::= { hwPoeGroups 4 } hwPoeTrapObjectsGroup OBJECT-GROUP OBJECTS { hwPoePdPriority, hwPoeSlotNum, hwPoeCurConsumPower,hwPoeConsumPowerThreshold,hwPoeDeviceID,hwFrameID,hwPoeChipID ,hwTrapProbableCause,hwPoeCardID,hwPoeSlotStr,hwPoeTrapFaultID} STATUS current DESCRIPTION "Description." ::= { hwPoeGroups 5 } hwPoePowerInfoGroup OBJECT-GROUP OBJECTS { hwPoePowerInfoDeviceName, hwPoePowerInfoDeviceTotalPower, hwPoePowerInfoDeviceTotalAvailablePower, hwPoePowerInfoDeviceReservedPower, hwPoePowerInfoDeviceUsedPower, hwPoePowerInfoDeviceRemainPower } STATUS current DESCRIPTION "This object indicates the POE's power information table group." ::= { hwPoeGroups 6 } hwPoeMultiMcuGroup OBJECT-GROUP OBJECTS { hwPoeMultiMcuMaximumPower, hwPoeMultiMcuAvailablePower, hwPoeMultiMcuPowerRcvPercent, hwPoeMultiPowerUtilizationThreshold } STATUS current DESCRIPTION "This object indicates the POE's multi-mcu table group." ::= { hwPoeGroups 7 } END -- -- HUAWEI-POE-MIB.mib --