-- ============================================================================ -- Copyright (C) 2019 by HUAWEI TECHNOLOGIES. All rights reserved. -- Description: The MIB module defines MIB objects which include Environment Monitor Unit, -- Analog Environment data, Digital Environment data, Out data and -- Fan data Monitor management MIB interfaces. -- Reference: -- Version: V3.95 -- ============================================================================ HUAWEI-ENVIRONMENT-MIB DEFINITIONS ::= BEGIN IMPORTS huaweiUtility FROM HUAWEI-MIB Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI DisplayString, RowStatus FROM SNMPv2-TC hwFrameIndex FROM HUAWEI-DEVICE-MIB; hwEnvironment MODULE-IDENTITY LAST-UPDATED "201909250000Z" ORGANIZATION "Huawei Technologies Co.,Ltd." CONTACT-INFO "Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com Email: support@huawei.com " DESCRIPTION "The MIB module defines MIB objects which include Environment Monitor Unit, Analog Environment data, Digital Environment data, Out data and Fan data Monitor management MIB interfaces. " -- Revision history REVISION "201909250000Z" DESCRIPTION "V3.95, modified the value list of hwFailureCause." REVISION "201812260000Z" DESCRIPTION "V3.94, modified the value list of hwEnvEmuPower." REVISION "201808220000Z" DESCRIPTION "V3.93, add hwOpticalModuleAbsenceTrap" REVISION "201808160000Z" DESCRIPTION "V3.92, add the leaf of hwORCH0CurrentInputVoltage1, hwORCH0CurrentInputVoltage2, hwORCH1CurrentInputVoltage1, hwORCH1CurrentInputVoltage2, hwOTCH0CurrentInputVoltage1, hwOTCH0CurrentInputVoltage2, hwOTCH1CurrentInputVoltage1, hwOTCH1CurrentInputVoltage2. add the leaf of hwOpticalDevType for the hwOpticalModuleEntry. add the object of hwOpticalDevType for the hwOpticalModuleTypeMismatchTrap. add the object of hwOpticalDevType for the hwOpticalModuleTypeMismatchRestoreTrap." REVISION "201807250000Z" DESCRIPTION "V3.91, add hwORRFPowerChangeThreshold, hwORCHN0RFPowerReferenceValue, hwORCHN0RFPowerChangeValue. add hwORCHN1RFPowerReferenceValue, hwORCHN1RFPowerChangeValue." REVISION "201806070000Z" DESCRIPTION "V3.90, add hwORRFPowerRefValueTrap, hwORRFPowerChangeValueTrap, hwOpticalReceiverRfChangeFaultTrap." REVISION "201806050000Z" DESCRIPTION "V3.89, add the leaf of hwEmmDoorLockOpenLockTrap, add the parameter of hwUnlockMode, hwUnlockSN, hwUnlockTime" REVISION "201804110000Z" DESCRIPTION "V3.88, add the leaf of hwONCfgOpticalWorkMode, hwONRuninfoOpticalWorkMode, hwONSmartCapability. add the leaf of hwOTCh0RuninfoOpticalLowPassFilter, hwOTCh1RuninfoOpticalLowPassFilter for the Optical transmitter. modify the optical state in hwORCh0OnlineState, hwORCh1OnlineState, hwOTCh0OnlineState and hwOTCh1OnlineState leaf node." REVISION "201803200000Z" DESCRIPTION "V3.87, modified the description of hwElockRightRowStatus and hwElockRightExpireTime." REVISION "201802070000Z" DESCRIPTION "V3.86, add table hwSirenTable, hwElockTable, hwElockRightTable add the leaf of hwEmmDoorLockCommFailTrap, hwEmmDoorLockCommRecoverTrap for door lock communication fial alarm . add the leaf of hwEmmDoorLockAbnormalUnlockTrap, hwEmmDoorLockAbnormalUnlockRecoverTrap for door lock unlocked abnormally alarm " REVISION "201801310000Z" DESCRIPTION "V3.85, add hwOpticalModuleTypeMismatchTrap and hwOpticalModuleTypeMismatchRestoreTrap. add hwOpticalModuleTable, hwOpticalModuleEntry and hwOpticalModuleType. " REVISION "201801160000Z" DESCRIPTION "V3.84, add the leaf of hwOTCH0RFAttValue, hwOTCH1RFAttValue for the Optical transmitter. add hwORCh0OnlineState, hwORCh1OnlineState, hwOTCh0OnlineState, hwOTCh1OnlineState. " REVISION "201801030000Z" DESCRIPTION "V3.83, add opticaltransmitter and dualchannelopticaltransmitter type in hwORType." REVISION "201711270000Z" DESCRIPTION "V3.82, add the leaf of hwOTCfgOpticalWorkMode, hwOTRuninfoOpticalWorkMode for the Optical transmitter." REVISION "201707170000Z" DESCRIPTION "V3.81, add the leaf of hwEmmDigAcInputPowerOffTrap and hwEmmDigAcInputPowerRecoverTrap for digital alarm." REVISION "201705170000Z" DESCRIPTION "V3.80, add the leaf of hwOTCH1WaveLength for the Optical transmitter. modified the mib node name and description of hwON5VVoltage. modified the mib node name and description of hwON24VVoltage." REVISION "201703240000Z" DESCRIPTION "V3.79, add the leaf of hwEmmDigFanSpeedAbnormalTrap and hwEmmDigFanSpeedRecoverTrap for fan digital alarm." REVISION "201608310000Z" DESCRIPTION "V3.78, modify the description of hwFanUnitSpeed node" REVISION "201607180000Z" DESCRIPTION "V3.77, add protect-switch channel policy(combiner) for dual-channel optical receiver. add hwORRFCH1PowerValue, hwORRFCH1PowerAlarmState leaf node, add hwModuleOpticalCombinerRFPowerFailTrap, hwModuleOpticalCombinerRFPowerRecoverTrap for optical trap. add hwFanUnitTable, HwFanUnitEntry, hwFanUnitIndex, hwFanUnitSpeed for fan speed querry" REVISION "201606240000Z" DESCRIPTION "V3.76, add hwORCfgChannel0AGCMode,hwORCfgChannel1AGCMode,hwORRuninfoChannel0AGCMode,hwORRuninfoChannel1AGCMode." REVISION "201602140000Z" DESCRIPTION "V3.75, add optical type(Shutdown) in hwONCOMState leaf node." REVISION "201602010000Z" DESCRIPTION "V3.74, Delete BITS from HUAWEI-ENVIRONMENT-MIB DEFINITIONS" REVISION "201601290000Z" DESCRIPTION "V3.73, modified the Description of hwORRFPowerLowThreshold." REVISION "201512170000Z" DESCRIPTION "V3.72, modified the Description of hwORRFPowerLowThreshold. modified the Description of hwORRFPowerHighThreshold." REVISION "201511120000Z" DESCRIPTION "V3.71, Correct the node hwOpticalPowerValue from Integer32 to OCTET STRING. Correct the node hwOpticalChnIndex, hwOpticalPowerValue, hwOpticalBiasValue from read-only to accessible-for-notify." REVISION "201509070000Z" DESCRIPTION "V3.70, modified the Description of hwEnvEmuPower. modified the Description of hwEnvEmuTypeName. added enum elabel(invalid:-1) in hwFanControlMode leaf node. modified the Description of hwFanTypeDescription. modified the Description of hwTcuHeatExchangerType." REVISION "201508271000Z" DESCRIPTION "V3.69, add emu type(emub:47) in hwEnvEmuType leaf node. add the hwAnaSignalHigh and hwAnaSignalLow in hwAnaChannelEntry leaf node." REVISION "201508241000Z" DESCRIPTION "V3.68, modified the Description of hwONModelNumber, hwONHardwareVer, hwONSoftwareVer, hwOROpticalPowerValue, hwOROpticalPowerAlarmState, hwOROpticalPowerLowThreshold, hwOROpticalPowerHighThreshold, hwOROpticalAGCStart, hwORRFPowerValue, hwON5VVoltage, hwON24VVoltage, hwORAGCRange, hwOTOpticalOutputPowerValue, hwOTOpticalOutputPowerAlarmState, hwOTOpticalOutputPowerLowThreshold, hwOTOpticalOutputPowerHighThreshold, hwOTBiasValue, hwOTBiasAlarmState, hwOTBiasLowThreshold, hwOTBiasHighThreshold, hwOTWaveLength, hwOROpticalActiveChannel, hwOROpticalCH1PowerValue, hwOROpticalCH1PowerAlarmState, hwOROpticalCH1PowerLowThreshold, hwOROpticalCH1PowerHighThreshold, hwOROpticalCH1AGCStart, hwORAGCCH1Range, hwOTOpticalOutputCH1PowerValue, hwOTOpticalOutputCH1PowerAlarmState, hwOTOpticalOutputCH1PowerLowThreshold, hwOTOpticalOutputCH1PowerHighThreshold, hwOTCH1BiasValue, hwOTCH1BiasAlarmState, hwOTCH1BiasLowThreshold, hwOTCH1BiasHighThreshold." REVISION "201508131000Z" DESCRIPTION "V3.67, modified the Description of hwTcuInternalFanRev. modified the Description of hwTcuExternalFanRev. modified the Description of hwTcuStartHeatTemp. modified the Description of hwTcuStopHeatTemp. modified the Description of hwCurrentTemp. modified the Description of hwAnaCurrentValue. modified the Description of hwEnvVersion." REVISION "201508121200Z" DESCRIPTION "V3.67, add hwOTOpticalOutputCH1PowerValue, hwOTOpticalOutputCH1PowerAlarmState, hwOTOpticalOutputCH1PowerLowThreshold, hwOTOpticalOutputCH1PowerHighThreshold hwOTCH1BiasValue, hwOTCH1BiasAlarmState, hwOTCH1BiasLowThreshold, hwOTCH1BiasHighThreshold for Dual channel Optical-transmitter. modified hwOTWaveLength, hwORType for Dual channel Optical-transmitter." REVISION "201507281200Z" DESCRIPTION "V3.66, add hwModuleOpticalTransmitterPowerFailTrap, hwModuleOpticalTransmitterPowerRecoverTrap, hwModuleOpticalTransmitterBiasRecoverTrap, hwModuleOpticalTransmitterBiasFailTrap for optical trap. modified hwOpticalReceiverPowerFailTrap, hwOpticalReceiverPowerRecoverTrap for Dual channel Optical-Receiver." REVISION "201504231200Z" DESCRIPTION "V3.65, modified the size of hwONProductDate." REVISION "201503281200Z" DESCRIPTION "V3.64, modified the parameter of hwOpticalReceiverDualChnPowerFailTrap, hwOpticalReceiverDualChnPowerRecoverTrap, hwOpticalReceiverPowerFailTrap, hwOpticalReceiverPowerRecoverTrap, hwOpticalReceiverRFPowerFailTrap, hwOpticalReceiverRFPowerRecoverTrap, hwOpticalTransmitterPowerFailTrap and hwOpticalTransmitterPowerRecoverTrap. modified the description of hwOROpticalWorkMode and hwOROpticalActiveChannel. add hwOpticalPowerTable, hwOpticalParaEntry, hwOpticalChnIndex and hwOpticalPowerValue for Optical node. add hwOROpticalPowerValueTrap, hwORRFPowerValueTrap adn hwOTOpticalOutputPowerValueTrap for optical trap. add invalid type in hwORType. delete the mib node hwOROpticalFailChannelId." REVISION "201502271000Z" DESCRIPTION "V3.63, modified the mib node name of hwOpticalNodeTable. add hwOROpticalWorkMode, hwOROpticalActiveChannel, hHwOROpticalCH1PowerValue, hwOROpticalCH1PowerAlarmState, hwOROpticalCH1PowerLowThreshold, hwOROpticalCH1PowerHighThreshold, hwOROpticalCH1AGCStart, hwORAGCCH1Range, hwORType, hwOpticalDualChnProtectSwitchTrap, hwOROpticalFailChannelId for Dual channel Optical-Receiver. modify hwOpticalReceiverPowerFailTrap, hwOpticalReceiverPowerRecoverTrap for Dual channel Optical-Receiver." REVISION "201502051150Z" DESCRIPTION "V3.62, add hwAnaMonitorState node for power(smu power4830) analog alarm monitor, add hwDigMonitorState node for power(smu power4830) default digital alarm monitor" REVISION "201412162050Z" DESCRIPTION "V3.61, Correct the node hwEnvRowStatus, hwAnaRowStatus,hwDigRowStatus, hwControlOutRowStatus,hwFanRowStatus from read-write to read-create." REVISION "201411292050Z" DESCRIPTION "V3.60, add emu type(rpsr:46) in hwEnvEmuType leaf node." REVISION "201410092030Z" DESCRIPTION "V3.59 correct the description of hwAnaType and hwAnaAlarmID value list." REVISION "201406040900Z" DESCRIPTION "V3.58, add emu type(h901VESC:45) in hwEnvEmuType leaf node. modified the trap parameter hwAnaAlarmID to hwAnaChannelIndex, include: hwEmmAnaUnnamedFaultTrap hwEmmAnaCurrentFaultTrap hwEmmAnaHumyFaultTrap hwEmmAnaTempFaultTrap hwEmmAnaVoltFaultTrap hwEmmAnaUnnamedRecoverTrap hwEmmAnaCurrentRecoverTrap hwEmmAnaHumyRecoverTrap hwEmmAnaTempRecoverTrap hwEmmAnaVoltRecoverTrap" REVISION "201404010900Z" DESCRIPTION "V3.57, modified the mib node name of hwOpticalreceiverTable. add hwOTOpticalOutputPowerValue, hwOTOpticalOutputPowerAlarmState, hwOTOpticalOutputPowerLowThreshold, hwOTOpticalOutputPowerHighThreshold, hwOTBiasValue, hwOTBiasAlarmState, hwOTBiasLowThreshold, hwOTBiasHighThreshold, hwOTWaveLength for Optical-transmitter. add hwOpticalTransmitterPowerFailTrap, hwOpticalTransmitterPowerRecoverTrap hwOpticalTransmitterBiasFailTrap, hwOpticalTransmitterBiasRecoverTrap for Optical-transmitter." REVISION "201402270900Z" DESCRIPTION "V3.56, correct the description of hwEnvEmuType's value list." REVISION "201402110900Z" DESCRIPTION "V3.55, modified the rf power unit from dBuV to dBmV." REVISION "201308050900Z" DESCRIPTION "V3.54, modified the descriptions of hwEmmEmuHardwareFaultTrap." REVISION "201306170900Z" DESCRIPTION "V3.53, modified the range of hwORRFPowerLowThreshold and hwORRFPowerHighThreshold for Optical-Receiver in hwEnvironmentInfoTable leaf node." REVISION "201305130900Z" DESCRIPTION "V3.52, add hwOpticalReceiverFailTrap, hwOpticalReceiverRecoverTrap, hwOpticalReceiverPowerFailTrap, hwOpticalReceiverPowerRecoverTrap, hwOpticalReceiverRFPowerFailTrap, hwOpticalReceiverRFPowerRecoverTrap for Optical-Receiver." REVISION "201301240900Z" DESCRIPTION "V3.51, modified this MIB for supporting Optical-receiver.add hwOpticalreceiverTable (optical-receiver) in hwEnvironmentInfoTable leaf node." REVISION "201211190900Z" DESCRIPTION "V3.50, add Digital alarm type(hard-fault:23) in hwDigAlarmID leaf node." REVISION "201211051000Z" DESCRIPTION "V3.49, add emu type(H801PMU:44) in hwEnvEmuType leaf node." REVISION "201210251700Z" DESCRIPTION "V3.48, add emu type(LeadAcidBattery:43) in hwEnvEmuType leaf node." REVISION "201209241700Z" DESCRIPTION "V3.47, add hwEnvEmuTypeName the length is 30 bytes" REVISION "201207231700Z" DESCRIPTION "V3.46, add emu type(H801VESC:42) in hwEnvEmuType leaf node." REVISION "201201140900Z" DESCRIPTION "V3.45, add emu type(vpea:41) in hwEnvEmuType leaf node." REVISION "201111100900Z" DESCRIPTION "V3.44, add emu type(smu:40) in hwEnvEmuType leaf node." REVISION "201108080900Z" DESCRIPTION "V3.43, add the leaf of hwEmmDigitalSwitchOpenTrap and hwEmmDigitalSwitchCloseTrap for ESC digital alarm." REVISION "201105120900Z" DESCRIPTION "V3.42, modified the value list of hwFanControlMode. " REVISION "201103180900Z" DESCRIPTION "V3.41, added emu type(transemu:39) in hwEnvEmuType leaf node. added digital-alarm(DC voltage and Output switch) in hwDigAlarmID leaf node." REVISION "201101180900Z" DESCRIPTION "V3.40, added hwEmmFanCriticalBlockFaultTrap and hwEmmFanCriticalBlockRecoverTrap for Fan critical block." REVISION "201011100000Z" DESCRIPTION "V3.39, modified the description of the alarm objects in this MIB file for standard trap. modified the description of the hwEnvironmentInfoEntry,hwEnvEmuType,hwAnaChannelEntry, hwDigChannelEntry,hwDigAlarmID,hwControlOutEntry,hwControlOutAdminStatus and hwFanEntry." REVISION "201008200900Z" DESCRIPTION "V3.38, modified the description of the objects in this MIB file for standard trap. Deleted hwEmmDigMainsupplyFaultTrap and hwEmmDigMainsupplyRecoverTrap,which were moved to HUAWEI-POWER-MIB." REVISION "201007190900Z" DESCRIPTION "V3.37, modified the Objects of the hwEmmEmuHardwareRecoverTrap and hwEmmEmuHardwareFaultTrap for standard trap. Modified the value of hwFailureCause. Modified the description of hwFailureCause, hwFanStatus, hwEnvAutofindNodeId, and hwEnvAutofindEmuType." REVISION "201006100900Z" DESCRIPTION "V3.36, added enum elabel(liFeBattery:38) in hwEnvEmuType leaf node for the supporting LiFeBattery. " REVISION "201005300900Z" DESCRIPTION "V3.35, modified description of hwEnvironmentInfoTable." REVISION "201005180900Z" DESCRIPTION "V3.34, modified this MIB for supporting Power3000." REVISION "201004080900Z" DESCRIPTION "V3.33, modified this MIB for supporting Temperature Heat Exchange Unit" REVISION "201003270900Z" DESCRIPTION "V3.32, modified this MIB for clearing Simple Tester errors and warnings." REVISION "201003240900Z" DESCRIPTION "V3.31, modified this MIB for clearing Simple Tester errors and warnings." REVISION "201002220900Z" DESCRIPTION "V3.30, added hwEnvAutofindNodeId for DT." REVISION "201002060900Z" DESCRIPTION "V3.29, added hwEnvironTraps for DT." REVISION "201001290900Z" DESCRIPTION "V3.28, deleted simptester mib compile errors and warnings." REVISION "200907200900Z" DESCRIPTION "V3.27, added hwEnvEmuPower." REVISION "200905050000Z" DESCRIPTION "V3.26, added hwEnvCLEICode." REVISION "200211290000Z" DESCRIPTION "V1.00, initial version." ::= { huaweiUtility 1 } -- 1.3.6.1.4.1.2011.6.1.1 hwEnvironmentMon OBJECT IDENTIFIER ::= { hwEnvironment 1 } -- 1.3.6.1.4.1.2011.6.1.1.1 hwEnvironmentInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HwEnvironmentInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Information table of Environment Monitor Unit. The Environment Monitor Unit is some kind of Environment monitoring device and is used to monitor many kinds of Environment data. The maximum number of Environment Monitor Units in one device node is 64. The index of this table is hwEnvEmuIndex. hwEnvEmuIndex is the index of one Environment Monitor Unit. " ::= { hwEnvironmentMon 1 } -- 1.3.6.1.4.1.2011.6.1.1.1.1 hwEnvironmentInfoEntry OBJECT-TYPE SYNTAX HwEnvironmentInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Information table of Environment Monitor Unit. The Environment Monitor Unit is some kind of Environment monitoring device and is used to monitor many kinds of Environment data. The maximum number of Environment Monitor Units in one device node is 64. The index of this entry is hwEnvEmuIndex. hwEnvEmuIndex is the index of one Environment Monitor Unit. " INDEX { hwEnvEmuIndex } ::= { hwEnvironmentInfoTable 1 } HwEnvironmentInfoEntry ::= SEQUENCE { hwEnvEmuIndex Integer32, hwEnvEmuType INTEGER, hwEnvBoardName DisplayString, hwEnvCommState INTEGER, hwEnvRowStatus RowStatus, hwEnvVersion DisplayString, hwEnvFrameId Integer32, hwEnvAdminStatus INTEGER, hwEnvSlaveNodeId Integer32, hwEnvComType INTEGER, hwEnvCLEICode OCTET STRING, hwEnvEmuPower Integer32, hwEnvEmuTypeName DisplayString } -- 1.3.6.1.4.1.2011.6.1.1.1.1.1 hwEnvEmuIndex OBJECT-TYPE SYNTAX Integer32 (0..2048) MAX-ACCESS read-only STATUS current DESCRIPTION " hwEnvEmuIndex is the index of the Environment monitoring unit, used as the index of hwEnvironmentInfoTable. Range: 0 - 2048 " ::= { hwEnvironmentInfoEntry 1 } -- 1.3.6.1.4.1.2011.6.1.1.1.1.2 hwEnvEmuType OBJECT-TYPE SYNTAX INTEGER { h302ESC(1), h303ESC(2), h4875(3), h301ESC(4), switch(5), fanEscFrame(6), fanFrame(7), h4845(8), fanFCBFrame(9), fanFDMUFrame(10), h304ESC(11), pwma(12), h561esc(13), h801esc(14), h612pwbp(15), pse158(16), h4805(19), pdu(20), acrmu(21), acfan(22), dcfan(23), rmun1509(24), onps150(25), h801pmix(26), h4875L(27), miniESC(28), h831VESC(29), h601VESC(30), h4830L(31), h801citx(32), h801citd(33), h831ccuh(34), h831pmu(35), pwr3000(36), tcu(37), liFeBattery(38), transemu(39), smu(40), vpea(41), h801VESC(42), leadAcidBattery(43), h801PMU(44), h901VESC(45), rpsr(46), emub(47), other(255) } MAX-ACCESS read-write STATUS current DESCRIPTION " Type of the physical monitoring devices associated with the environment monitoring unit. Options: 1.h302ESC(1) -Type of the physical monitoring devices is H302ESC 2.h303ESC(2) -Type of the physical monitoring devices is H303ESC 3.h4875(3) -Type of the physical monitoring devices is 4875 power monitoring frame 4.h301ESC(4) -Type of the physical monitoring devices is H301ESC 5.switch(5) -Distribute monitoring frame 6.fanEscFrame(6) -ESC monitoring fan frame 7.fanFrame(7) -FAN 8.h4845(8) -Pwr4845 9.fanFCBFrame(9) -FCB monitoring fan frame 10.fanFDMUFrame(10) -FDMU monitoring fan frame 11.h304ESC(11) -provides the management function of battery 12.pwma(12) -Type of the physical monitoring devices is pwma 13.h561esc(13) -H561ESC 14.h801esc(14) -H801ESC 15.h612pwbp(15) -H612pwbp 16.pse158(16) -pse158 17.h4805(19) -h4805 18.pdu(20) -pdu 19.acrmu(21) -ac_rmu 20.acfan(22) -ac_fan 21.dcfan(23) -dc_fan 22.rmun1509(24) -rmun1509 23.onps150(25) -onps150 24.h801pmix(26) -h801pmix 25.h4875L(27) -Pwr4875L 26.miniESC(28) -MINIESC 27.h831VESC(29) -H831VESC 28.h601VESC(30) -H601VESC 29.h4830L(31) -Pwr4830L 30.h801citx(32) -H801CITX 31.h801citd(33) -H801CITD 32.h831ccuh(34) -h831ccuh 33.h831pmu(35) -h831pmu 34.pwr3000(36) -Pwr3000 35.tcu(37) -TCU 36.liFeBattery(38) -liFeBattery 37.transemu(39) -a type of emu for transport environment information to managment center 38.smu(40) -SMU 39.vpea(41) -VPEA 40.h801VESC(42) -H801VESC 41.leadAcidBattery(43) -LeadBattery 42.h801PMU(44) -H801PMU 43.h901VESC(45) -H901VESC 44.rpsr(46) -Remote Power System RemoteUnit 45.emub(47) -EMUB 46.other(255) -Unknow " ::= { hwEnvironmentInfoEntry 2 } -- 1.3.6.1.4.1.2011.6.1.1.1.1.3 hwEnvBoardName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Name of the environment monitoring unit. " ::= { hwEnvironmentInfoEntry 3 } -- 1.3.6.1.4.1.2011.6.1.1.1.1.4 hwEnvCommState OBJECT-TYPE SYNTAX INTEGER { normal(1), shutdown(2), fault(3), abnormal(4), config(5) } MAX-ACCESS read-only STATUS current DESCRIPTION " Status of the communication between the environment monitoring unit and the device. The environmental condition can be tested only when the communication is normal. Options: 1.normal(1) - indicates that communication state is normal 2.shutdown(2) - indicates that communication state is shutdown 3.fault(3) - indicates that communication state is fault 4.abnormal(4) - indicates that communication state is abnormal 5.config(5) - indicates that communication state is config " ::= { hwEnvironmentInfoEntry 4 } -- 1.3.6.1.4.1.2011.6.1.1.1.1.5 hwEnvRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " RowStatus standard operation. The creation and deletion operations are supported currently. " ::= { hwEnvironmentInfoEntry 5 } -- 1.3.6.1.4.1.2011.6.1.1.1.1.6 hwEnvVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Version information of the environment monitoring unit. invalid(zero-length) " ::= { hwEnvironmentInfoEntry 6 } -- 1.3.6.1.4.1.2011.6.1.1.1.1.7 hwEnvFrameId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " ID of the shelf housing the environment monitoring unit. " ::= { hwEnvironmentInfoEntry 7 } -- 1.3.6.1.4.1.2011.6.1.1.1.1.8 hwEnvAdminStatus OBJECT-TYPE SYNTAX INTEGER { noOperation(1), reset(2), manage(3), unmanage(4), clearsmokealarm(5) } MAX-ACCESS read-write STATUS current DESCRIPTION " The management status of the monitoring unit. Options: 1.noOperation(1) -no any operation 2.reset(2) -reset the monitoring board 3.manage(3) -manage the monitoring unit 4.unmanage(4) -undo manage the monitoring unit 5.clearsmokealarm(5) -clear the smoke alarm for miniEsc " ::= { hwEnvironmentInfoEntry 8 } -- 1.3.6.1.4.1.2011.6.1.1.1.1.9 hwEnvSlaveNodeId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " ID of the slave object that the environment monitoring unit belongs to. The environment monitoring unit uses the slave object ID to communicate with the upstream equipment. " ::= { hwEnvironmentInfoEntry 9 } -- 1.3.6.1.4.1.2011.6.1.1.1.1.10 hwEnvComType OBJECT-TYPE SYNTAX INTEGER { unknown(1), serialRS485(2), serialRS232(3), serialRS422(4) } MAX-ACCESS read-write STATUS current DESCRIPTION " The serial communication protocol type between the monitoring unit and the upstream equipment. The protocol types used are as follows: Options: 1.unknown(1) -The protocol types is unknown 2.serialRS485(2) -The protocol types is serialRS485 3.serialRS232(3) -The protocol types is serialRS232 4.serialRS422(4) -The protocol types is serialRS422 " ::= { hwEnvironmentInfoEntry 10 } -- 1.3.6.1.4.1.2011.6.1.1.1.1.11 hwEnvCLEICode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..640)) MAX-ACCESS read-only STATUS current DESCRIPTION " Environment CLEI Code. " ::= { hwEnvironmentInfoEntry 11 } -- 1.3.6.1.4.1.2011.6.1.1.1.1.12 hwEnvEmuPower OBJECT-TYPE SYNTAX Integer32 (-1..255) MAX-ACCESS read-only STATUS current DESCRIPTION " Power of the environment monitoring equipment associated with the environment monitoring unit. Unit: Watt. Invalid:-1. " ::= { hwEnvironmentInfoEntry 12 } -- 1.3.6.1.4.1.2011.6.1.1.1.1.13 hwEnvEmuTypeName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Name of the environment type. Invalid: null string. " ::= { hwEnvironmentInfoEntry 13 } -- 1.3.6.1.4.1.2011.6.1.1.2 hwAnaChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF HwAnaChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Information table of the analog parameters monitored. The indexes of this table are hwEnvEmuIndex or hwAnaChannelIndex. hwEnvEmuIndex is the index of the environment monitoring unit, and hwAnaChannelIndex is the index of the analog parameter that is monitored by a monitoring unit. " ::= { hwEnvironmentMon 2 } -- 1.3.6.1.4.1.2011.6.1.1.2.1 hwAnaChannelEntry OBJECT-TYPE SYNTAX HwAnaChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Information table of the analog parameters monitored. The indexes of this entry are hwEnvEmuIndex or hwAnaChannelIndex. hwEnvEmuIndex is the index of the environment monitoring unit, and hwAnaChannelIndex is the index of the analog parameter that is monitored by a monitoring unit. " INDEX { hwEnvEmuIndex, hwAnaChannelIndex } ::= { hwAnaChannelTable 1 } HwAnaChannelEntry ::= SEQUENCE { hwAnaChannelIndex Integer32, hwAnaName DisplayString, hwAnaType INTEGER, hwAnaMeasureType DisplayString, hwAnaWorkHigh Integer32, hwAnaWorkLow Integer32, hwAnaAlmHigh Integer32, hwAnaAlmLow Integer32, hwAnaCurrentValue Integer32, hwAnaAlarmState INTEGER, hwAnaRowStatus RowStatus, hwAnaAlarmID INTEGER, hwAnaMonitorState INTEGER, hwAnaSignalHigh Integer32, hwAnaSignalLow Integer32 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.1 hwAnaChannelIndex OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION " Index of the analog parameter that is monitored by the monitoring unit. Range: 0 - 255 " ::= { hwAnaChannelEntry 1 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.2 hwAnaName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Name of the analog parameter that is monitored by a monitoring unit. " ::= { hwAnaChannelEntry 2 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.3 hwAnaType OBJECT-TYPE SYNTAX INTEGER { invalid(-1), voltage(1), electriccurrent(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " This object indicates the type of the sensor that is used to test the Analog parameter. Options: 1.invalid(-1) -there is no valid sensor 2.voltage(1) -voltage sensor currently 3.electriccurrent(2) -electric current sensor currently " ::= { hwAnaChannelEntry 3 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.4 hwAnaMeasureType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " This object indicates the unit of the analog parameter that is tested. " ::= { hwAnaChannelEntry 4 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.5 hwAnaWorkHigh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " High limit of the analog normal work " ::= { hwAnaChannelEntry 5 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.6 hwAnaWorkLow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Low limit of the analog normal work " ::= { hwAnaChannelEntry 6 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.7 hwAnaAlmHigh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " High limit of the analog alarm. The alarm is produced when the measurement value is higher than this value " ::= { hwAnaChannelEntry 7 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.8 hwAnaAlmLow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The low limit of the analog alarm. The alarm is produced when the measurement value is lower than this value. " ::= { hwAnaChannelEntry 8 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.9 hwAnaCurrentValue OBJECT-TYPE SYNTAX Integer32 UNITS "milli" MAX-ACCESS read-only STATUS current DESCRIPTION " The actual measurement value of the present analog. Unit: milli invalid: 0x7fffffff " ::= { hwAnaChannelEntry 9 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.10 hwAnaAlarmState OBJECT-TYPE SYNTAX INTEGER { normal(1), overWorkHigh(2), belowWorkLow(3), abnormal(4), invalid(-1) } MAX-ACCESS read-only STATUS current DESCRIPTION " The status of the present monitored. Options: 1.normal(1) -indicates that the measurement value is lower than the set high limit of the alarm, and higher than the low limit 2.overWorkHigh(2) -indicates that the measurement value is higher than the high limit of the alarm 3.belowWorkLow(3) -indicates that the measurement value is lower than the low limit of the alarm 4.abnormal(4) -indicates that the measurement value is outside the scope of limit of the alarm 5.invalid(-1) -indicates that the device can not get the value, e.g. the EMU does not support this operation, or the EMU state is abnormal " ::= { hwAnaChannelEntry 10 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.11 hwAnaRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " RowStatus standard operation. The values 1 and 2 are supported currently. 1 indicates the activation status, and 2 indicates the non-activation status. " ::= { hwAnaChannelEntry 11 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.12 hwAnaAlarmID OBJECT-TYPE SYNTAX INTEGER { temperature(1), humidity(2), voltage(3), electriccurrent(4), userDefinedAlarm0(100), userDefinedAlarm1(101), userDefinedAlarm2(102), userDefinedAlarm3(103), userDefinedAlarm4(104), userDefinedAlarm5(105), userDefinedAlarm6(106), userDefinedAlarm7(107), userDefinedAlarm8(108), userDefinedAlarm9(109), userDefinedAlarm10(110), userDefinedAlarm11(111), userDefinedAlarm12(112), userDefinedAlarm13(113), userDefinedAlarm14(114), userDefinedAlarm15(115), default(65535) } MAX-ACCESS read-write STATUS current DESCRIPTION " Analog alarm definition. Options: 1.temperature(1) -temperature alarm 2.humidity(2) -humidity alarm 3.voltage(3) -voltage alarm 4.electriccurrent(4) -electric current alarm 5.userDefinedAlarm0(100) -analog user-defined alarm 0 6.userDefinedAlarm1(101) -analog user-defined alarm 1 7.userDefinedAlarm2(102) -analog user-defined alarm 2 8.userDefinedAlarm3(103) -analog user-defined alarm 3 9.userDefinedAlarm4(104) -analog user-defined alarm 4 10.userDefinedAlarm5(105) -analog user-defined alarm 5 11.userDefinedAlarm6(106) -analog user-defined alarm 6 12.userDefinedAlarm7(107) -analog user-defined alarm 7 13.userDefinedAlarm8(108) -analog user-defined alarm 8 14.userDefinedAlarm9(109) -analog user-defined alarm 9 15.userDefinedAlarm10(110) -analog user-defined alarm 10 16.userDefinedAlarm11(111) -analog user-defined alarm 11 17.userDefinedAlarm12(112) -analog user-defined alarm 12 18.userDefinedAlarm13(113) -analog user-defined alarm 13 19.userDefinedAlarm14(114) -analog user-defined alarm 14 20.userDefinedAlarm15(115) -analog user-defined alarm 15 21.default(65535) -default analog alarm " ::= { hwAnaChannelEntry 12 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.13 hwAnaMonitorState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), invalid(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION " analog alarm(temperature,humidity,battery temperature) monitor flag value, The value 1 enable monitor, value 2 disable monitor. " ::= { hwAnaChannelEntry 13 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.14 hwAnaSignalHigh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " High limit of the analog signal. invalid: 0x7fffffff. " ::= { hwAnaChannelEntry 14 } -- 1.3.6.1.4.1.2011.6.1.1.2.1.15 hwAnaSignalLow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Low limit of the analog signal. invalid: 0x7fffffff. " ::= { hwAnaChannelEntry 15 } -- 1.3.6.1.4.1.2011.6.1.1.3 hwDigChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF HwDigChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Information table of the digital parameters monitored. The indexes of this table are hwEnvEmuIndex and hwDigChannelIndex. hwEnvEmuIndex is the index of the environment monitoring unit, and hwDigChannelIndex is the index of the digital parameter that is monitored by a monitoring unit. " ::= { hwEnvironmentMon 3 } -- 1.3.6.1.4.1.2011.6.1.1.3.1 hwDigChannelEntry OBJECT-TYPE SYNTAX HwDigChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Information table of the digital parameters monitored. The indexes of this entry are hwEnvEmuIndex and hwDigChannelIndex. hwEnvEmuIndex is the index of the environment monitoring unit, and hwDigChannelIndex is the index of the digital parameter that is monitored by a monitoring unit. " INDEX { hwEnvEmuIndex, hwDigChannelIndex } ::= { hwDigChannelTable 1 } HwDigChannelEntry ::= SEQUENCE { hwDigChannelIndex Integer32, hwDigChannelName DisplayString, hwAlmCondition INTEGER, hwDigChannelState INTEGER, hwDigRowStatus RowStatus, hwDigAlarmID INTEGER, hwDigMonitorState INTEGER } -- 1.3.6.1.4.1.2011.6.1.1.3.1.1 hwDigChannelIndex OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION " Index of the digital parameter that is monitored by a monitoring unit. Range: 0 - 255 " ::= { hwDigChannelEntry 1 } -- 1.3.6.1.4.1.2011.6.1.1.3.1.2 hwDigChannelName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Name of the digital parameter that is monitored by a monitoring unit. " ::= { hwDigChannelEntry 2 } -- 1.3.6.1.4.1.2011.6.1.1.3.1.3 hwAlmCondition OBJECT-TYPE SYNTAX INTEGER { lowLevelAlarm(1), highLevelAlarm(2), invalid(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION " Alarm conditions. Options: 1.lowLevelAlarm(1) -refers to the alarm produced when the digital sensor detects the low level 2.highLevelAlarm(2) -refers to the alarm produced when the digital sensor detects the high level 3.invalid(-1) -indicates that the device can not get the value, e.g. the EMU does not support this operation, or the EMU state is abnormal " ::= { hwDigChannelEntry 3 } -- 1.3.6.1.4.1.2011.6.1.1.3.1.4 hwDigChannelState OBJECT-TYPE SYNTAX INTEGER { normal(1), alarm(2), invalid(-1) } MAX-ACCESS read-only STATUS current DESCRIPTION " The status of the present monitored digital sensor Options: 1.normal(1) -indicates that the digital sensor works normally 2.alarm(2) -indicates that the digital sensor produces the alarm signal 3.invalid(-1) -indicates that the device can not get the value, e.g. the EMU does not support this operation, or the EMU state is abnormal " ::= { hwDigChannelEntry 4 } -- 1.3.6.1.4.1.2011.6.1.1.3.1.5 hwDigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " RowStatus standard operation. The values 1 and 2 are supported currently. 1 indicates the activation status, and 2 indicates the non-activation status. " ::= { hwDigChannelEntry 5 } -- 1.3.6.1.4.1.2011.6.1.1.3.1.6 hwDigAlarmID OBJECT-TYPE SYNTAX INTEGER { acvoltage(1), acswitch(2), batteryvoltage(3), batteryfuse(4), loadfuse(5), rectifier(6), dcpower(7), cupboarddoor(8), roomdoor(9), window(10), thief(11), wiring(12), fan(13), fire(14), fog(15), water(16), diesel(17), smell(18), aircondition(19), arrester(20), dcvoltage(21), outputswitch(22), hardFault(23), userDefinedAlarm0(100), userDefinedAlarm1(101), userDefinedAlarm2(102), userDefinedAlarm3(103), userDefinedAlarm4(104), userDefinedAlarm5(105), userDefinedAlarm6(106), userDefinedAlarm7(107), userDefinedAlarm8(108), userDefinedAlarm9(109), userDefinedAlarm10(110), userDefinedAlarm11(111), userDefinedAlarm12(112), userDefinedAlarm13(113), userDefinedAlarm14(114), userDefinedAlarm15(115), userDefinedAlarm16(116), userDefinedAlarm17(117), userDefinedAlarm18(118), userDefinedAlarm19(119), userDefinedAlarm20(120), userDefinedAlarm21(121), userDefinedAlarm22(122), userDefinedAlarm23(123), userDefinedAlarm24(124), userDefinedAlarm25(125), userDefinedAlarm26(126), userDefinedAlarm27(127), userDefinedAlarm28(128), userDefinedAlarm29(129), userDefinedAlarm30(130), userDefinedAlarm31(131), default(65535) } MAX-ACCESS read-write STATUS current DESCRIPTION " Digital alarm definition. Options: 1.acvoltage(1) -ac voltage alarm 2.acswitch(2) -ac switch alarm 3.batteryvoltage(3) -battery voltage alarm 4.batteryfuse(4) -battery fuse alarm 5.loadfuse(5) -load fuse alarm 6.rectifier(6) -rectifier alarm 7.dcpower(7) -dc power alarm 8.cupboarddoor(8) -cupboard alarm 9.roomdoor(9) -room door alarm 10.window(10) -window alarm 11.thief(11) -thief alarm 12.wiring(12) -wiring alarm 13.fan(13) -fan alarm 14.fire(14) -fire alarm 15.fog(15) -fog alarm 16.water(16) -water alarm 17.diesel(17) -diesel alarm 18.smell(18) -smell alarm 19.aircondition(19) -air-condition alarm 20.arrester(20) -arrester alarm 21.dcvoltage(21) -dc voltage 22.outputswitch(22) -output swith 23.hardFault(23) -hard-fault 24.userDefinedAlarm0(100) -digital user-defined alarm 0 25.userDefinedAlarm1(101) -digital user-defined alarm 1 26.userDefinedAlarm2(102) -digital user-defined alarm 2 27.userDefinedAlarm3(103) -digital user-defined alarm 3 28.userDefinedAlarm4(104) -digital user-defined alarm 4 29.userDefinedAlarm5(105) -digital user-defined alarm 5 30.userDefinedAlarm6(106) -digital user-defined alarm 6 31.userDefinedAlarm7(107) -digital user-defined alarm 7 32.userDefinedAlarm8(108) -digital user-defined alarm 8 33.userDefinedAlarm9(109) -digital user-defined alarm 9 34.userDefinedAlarm10(110) -digital user-defined alarm 10 35.userDefinedAlarm11(111) -digital user-defined alarm 11 36.userDefinedAlarm12(112) -digital user-defined alarm 12 37.userDefinedAlarm13(113) -digital user-defined alarm 13 38.userDefinedAlarm14(114) -digital user-defined alarm 14 39.userDefinedAlarm15(115) -digital user-defined alarm 15 40.userDefinedAlarm16(116) -digital user-defined alarm 16 41.userDefinedAlarm17(117) -digital user-defined alarm 17 42.userDefinedAlarm18(118) -digital user-defined alarm 18 43.userDefinedAlarm19(119) -digital user-defined alarm 19 44.userDefinedAlarm20(120) -digital user-defined alarm 20 45.userDefinedAlarm21(121) -digital user-defined alarm 21 46.userDefinedAlarm22(122) -digital user-defined alarm 22 47.userDefinedAlarm23(123) -digital user-defined alarm 23 48.userDefinedAlarm24(124) -digital user-defined alarm 24 49.userDefinedAlarm25(125) -digital user-defined alarm 25 50.userDefinedAlarm26(126) -digital user-defined alarm 26 51.userDefinedAlarm27(127) -digital user-defined alarm 27 52.userDefinedAlarm28(128) -digital user-defined alarm 28 53.userDefinedAlarm29(129) -digital user-defined alarm 29 54.userDefinedAlarm30(130) -digital user-defined alarm 30 55.userDefinedAlarm31(131) -digital user-defined alarm 31 56.default(65535) -digital alarm " ::= { hwDigChannelEntry 6 } -- 1.3.6.1.4.1.2011.6.1.1.3.1.7 hwDigMonitorState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), invalid(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION " default digital alarm(Door,Water,Smoke,Wiring) monitor flag value, The value 1 enable monitor, value 2 disable monitor. " ::= { hwDigChannelEntry 7 } -- 1.3.6.1.4.1.2011.6.1.1.4 hwControlOutTable OBJECT-TYPE SYNTAX SEQUENCE OF HwControlOutEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Monitored digital out table. This table indicates information about whether digital parameter is monitored. The indexes of this table are hwEnvEmuIndex and hwControlOutIndex. hwEnvEmuIndex is the index of the monitoring unit, and hwControlOutIndex is the index of the digital out table monitored in the monitoring unit. " ::= { hwEnvironmentMon 4 } -- 1.3.6.1.4.1.2011.6.1.1.4.1 hwControlOutEntry OBJECT-TYPE SYNTAX HwControlOutEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Monitored digital out table. This table indicates information about whether digital parameter is monitored. The indexes of this entry are hwEnvEmuIndex and hwControlOutIndex. hwEnvEmuIndex is the index of the monitoring unit, and hwControlOutIndex is the index of the digital out table monitored in the monitoring unit. " INDEX { hwEnvEmuIndex, hwControlOutIndex } ::= { hwControlOutTable 1 } HwControlOutEntry ::= SEQUENCE { hwControlOutIndex Integer32, hwControlOutName DisplayString, hwControlOutAdminStatus INTEGER, hwControlOutRowStatus RowStatus } -- 1.3.6.1.4.1.2011.6.1.1.4.1.1 hwControlOutIndex OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION " Index of the digital out table monitored in the monitoring unit Range: 0 - 255 " ::= { hwControlOutEntry 1 } -- 1.3.6.1.4.1.2011.6.1.1.4.1.2 hwControlOutName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Name of the monitored digital out table " ::= { hwControlOutEntry 2 } -- 1.3.6.1.4.1.2011.6.1.1.4.1.3 hwControlOutAdminStatus OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Control Out administration: executes the on/off operation. Options: 1. on(1) - trun on 2. off(2) - trun off " ::= { hwControlOutEntry 3 } -- 1.3.6.1.4.1.2011.6.1.1.4.1.4 hwControlOutRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " RowStatus standard operation. The values 1 and 2 are supported currently. 1 indicates the activation status, and 2 indicates the non-activation status. " ::= { hwControlOutEntry 4 } -- 1.3.6.1.4.1.2011.6.1.1.5 hwFanTable OBJECT-TYPE SYNTAX SEQUENCE OF HwFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Information table of fan monitoring. The index of this table is hwEnvEmuIndex that comes from hwEnvironmentInfoTable. hwEnvEmuIndex is the index of the monitoring unit whose monitoring type is fan. " ::= { hwEnvironmentMon 5 } -- 1.3.6.1.4.1.2011.6.1.1.5.1 hwFanEntry OBJECT-TYPE SYNTAX HwFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Information table of fan monitoring. The index of this entry is hwEnvEmuIndex that comes from hwEnvironmentInfoTable. hwEnvEmuIndex is the index of the monitoring unit whose monitoring type is fan. " INDEX { hwEnvEmuIndex } ::= { hwFanTable 1 } HwFanEntry ::= SEQUENCE { hwFanName DisplayString, hwFanControlMode INTEGER, hwFanControlState BITS, hwESCFanTempAutoOn Integer32, hwESCFanTempAutoOff Integer32, hwFanRowStatus RowStatus, hwCurrentTemp Integer32, hwFanSpeedMode INTEGER, hwFanSpeed Integer32, hwFanTypeDescription DisplayString } -- 1.3.6.1.4.1.2011.6.1.1.5.1.1 hwFanName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Fan name " ::= { hwFanEntry 1 } -- 1.3.6.1.4.1.2011.6.1.1.5.1.2 hwFanControlMode OBJECT-TYPE SYNTAX INTEGER { invalid(-1), manual(1), emuAuto(2), fixed(3), mainboardAuto(4) } MAX-ACCESS read-write STATUS current DESCRIPTION " The fan control modes of the fan frame. Options: 1.manual(1) -indicates that the fan is always on, and the fan speed can be manually adjusted 2.emuAuto(2) -indicates that the fan is in the automatic mode, and can be automatically controlled depending on the temperature of the fan 3.fixed(3) -indicates that the fan is in the fixed mode, and adjusting its speed is not allowed 4.mainboardAuto(4) -indicates that the fan is in the automatic mode, and can be automatically controlled depending on the temperature of the boards in the frame 5.invalid(-1) -indicates that the fan control mode is invalid. " ::= { hwFanEntry 2 } -- 1.3.6.1.4.1.2011.6.1.1.5.1.3 hwFanControlState OBJECT-TYPE SYNTAX BITS { fan1(0), fan2(1), fan3(2), fan4(3), fan5(4), fan6(5) } MAX-ACCESS read-write STATUS current DESCRIPTION " For ESC fan, all should be checked to turn on the fan, while all should not be checked to turn off the fan. Options: 1.fan1(0) -indicates that the first fan needs to be opened 2.fan2(1) -indicates that the second fan needs to be opened 3.fan3(2) -indicates that the third fan needs to be opened 4.fan4(3) -indicates that the fourth fan needs to be opened 5.fan5(4) -indicates that the fifth fan needs to be opened 6.fan6(5) -indicates that the sixth fan needs to be opened " ::= { hwFanEntry 3 } -- 1.3.6.1.4.1.2011.6.1.1.5.1.4 hwESCFanTempAutoOn OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The fan temperature set, in unit of centigrade. The MIB object only functions for the fan monitoring board of ESC and is not applicable to the type of fan monitoring board. Only when the fan control mode of the fan frame is hwFanControl =auto (3), the temperature control mode will take effect. When detecting the environment temperature higher than the set value, the fan will be on (or increase its rotation). " ::= { hwFanEntry 4 } -- 1.3.6.1.4.1.2011.6.1.1.5.1.5 hwESCFanTempAutoOff OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The fan temperature set, in unit of centigrade. The MIB object only functions for the fan monitoring board of ESC and is not applicable to the type of fan monitoring board. Only when the fan control mode of the fan frame is hwFanControl =auto (3), the temperature control mode will take effect. When detecting the environment temperature is lower than the set value, the fan will be turned off (decrease its rotation). " ::= { hwFanEntry 5 } -- 1.3.6.1.4.1.2011.6.1.1.5.1.6 hwFanRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " RowStatus standard operation. " ::= { hwFanEntry 6 } -- 1.3.6.1.4.1.2011.6.1.1.5.1.7 hwCurrentTemp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The present temperature value Unit: 0.01 degree invalid: 0x7fffffff " ::= { hwFanEntry 7 } -- 1.3.6.1.4.1.2011.6.1.1.5.1.8 hwFanSpeedMode OBJECT-TYPE SYNTAX INTEGER { continue(1), discontinue(2), percent(3), invalid(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION " The adjusting rotation mode of the fan. Options: 1.continue(1) -continuous control 2.discontinue(2) -discrete control 3.percent(3) -duty ratio control 4.invalid(-1) -indicates that the device can not get the value, e.g. the EMU does not support this operation, or the EMU state is abnormal " ::= { hwFanEntry 8 } -- 1.3.6.1.4.1.2011.6.1.1.5.1.9 hwFanSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " When hwFanSpeedMode is the continue mode, 0 indicates the present wind speed +1, while 1 indicates the present wind speed -1. When hwFanSpeedMode is discontinuous, 0 indicates fixed high speed, while 1 indicates fixed low speed. When hwFanSpeedMode is percent, the value delivered by the main control is the percent value, ranging from 35 to 100, used to initialize the rotation of fan for various device main controls. invalid(-1) indicates that the fan tray does not work normally. For example, the fan tray is disconnected from the control board, or some of the fans in the fan tray are blocked. " ::= { hwFanEntry 9 } -- 1.3.6.1.4.1.2011.6.1.1.5.1.10 hwFanTypeDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Fan Type Description. Invalid: null string. " ::= { hwFanEntry 10 } -- 1.3.6.1.4.1.2011.6.1.1.6 hwTcuTable OBJECT-TYPE SYNTAX SEQUENCE OF HwTcuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Information table of temperature control unit. The index of this table is hwEnvEmuIndex that comes from hwEnvironmentInfoTable. hwEnvEmuIndex is the index of the monitoring unit whose monitoring type is temperature control unit. " ::= { hwEnvironmentMon 6 } -- 1.3.6.1.4.1.2011.6.1.1.6.1 hwTcuEntry OBJECT-TYPE SYNTAX HwTcuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Information table of temperature control unit. The index of this entry is hwEnvEmuIndex that comes from hwEnvironmentInfoTable. hwEnvEmuIndex is the index of the monitoring unit whose monitoring type is temperature control unit. " INDEX { hwEnvEmuIndex } ::= { hwTcuTable 1 } HwTcuEntry ::= SEQUENCE { hwTcuHeatExchangerType DisplayString, hwTcuExternalFanRev Integer32, hwTcuInternalFanRev Integer32, hwTcuStartHeatTemp Integer32, hwTcuStopHeatTemp Integer32 } -- 1.3.6.1.4.1.2011.6.1.1.6.1.1 hwTcuHeatExchangerType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Heat Exchanger Type Description. Invalid: null string. " ::= { hwTcuEntry 1 } -- 1.3.6.1.4.1.2011.6.1.1.6.1.2 hwTcuExternalFanRev OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The rev of Heat Exchanger outer fan, in unit of RMP (rotate per minite), invalid(-1) " ::= { hwTcuEntry 2 } -- 1.3.6.1.4.1.2011.6.1.1.6.1.3 hwTcuInternalFanRev OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The rev of Heat Exchanger inner fan, in unit of RMP (rotate per minite), invalid(-1) " ::= { hwTcuEntry 3 } -- 1.3.6.1.4.1.2011.6.1.1.6.1.4 hwTcuStartHeatTemp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The temperature of Heat Exchanger starts to heat up, in unit of Celsius. default: 5 " ::= { hwTcuEntry 4 } -- 1.3.6.1.4.1.2011.6.1.1.6.1.5 hwTcuStopHeatTemp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The temperature of Heat Exchanger stops heating, in unit of Celsius. default: 25 " ::= { hwTcuEntry 5 } -- 1.3.6.1.4.1.2011.6.1.1.7 hwOpticalNodeTable OBJECT-TYPE SYNTAX SEQUENCE OF HwOpticalNodeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Information table of optical node unit. The index of this table is hwFrameIndex that comes from hwFrameTable. hwFrameIndex is the index of the optical node unit whose optical node type is optical node unit. " ::= { hwEnvironmentMon 7 } -- 1.3.6.1.4.1.2011.6.1.1.7.1 hwOpticalNodeEntry OBJECT-TYPE SYNTAX HwOpticalNodeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Information table of optical node unit. interface optical node config mode. " INDEX { hwFrameIndex } ::= { hwOpticalNodeTable 1 } HwOpticalNodeEntry ::= SEQUENCE { hwONCOMState INTEGER, hwONModelNumber DisplayString, hwONHardwareVer DisplayString, hwONSoftwareVer DisplayString, hwONProductDate OCTET STRING, hwOROpticalPowerValue Integer32, hwOROpticalPowerAlarmState INTEGER, hwOROpticalPowerLowThreshold Integer32, hwOROpticalPowerHighThreshold Integer32, hwOROpticalAGCStart Integer32, hwORRFPowerValue Integer32, hwORRFPowerAlarmState INTEGER, hwORRFPowerLowThreshold Integer32, hwORRFPowerHighThreshold Integer32, hwORRFAttValue Integer32, hwORRFSwitch INTEGER, hwONBarcode DisplayString, hwONCurrentInputVoltage1 Integer32, hwONCurrentInputVoltage2 Integer32, hwORAGCRange DisplayString, hwOTOpticalOutputPowerValue Integer32, hwOTOpticalOutputPowerAlarmState INTEGER, hwOTOpticalOutputPowerLowThreshold Integer32, hwOTOpticalOutputPowerHighThreshold Integer32, hwOTBiasValue Integer32, hwOTBiasAlarmState INTEGER, hwOTBiasLowThreshold Integer32, hwOTBiasHighThreshold Integer32, hwOTWaveLength Integer32, hwOROpticalWorkMode INTEGER, hwOROpticalActiveChannel Integer32, hwOROpticalCH1PowerValue Integer32, hwOROpticalCH1PowerAlarmState INTEGER, hwOROpticalCH1PowerLowThreshold Integer32, hwOROpticalCH1PowerHighThreshold Integer32, hwOROpticalCH1AGCStart Integer32, hwORAGCCH1Range DisplayString, hwORType INTEGER, hwOTOpticalOutputCH1PowerValue Integer32, hwOTOpticalOutputCH1PowerAlarmState INTEGER, hwOTOpticalOutputCH1PowerLowThreshold Integer32, hwOTOpticalOutputCH1PowerHighThreshold Integer32, hwOTCH1BiasValue Integer32, hwOTCH1BiasAlarmState INTEGER, hwOTCH1BiasLowThreshold Integer32, hwOTCH1BiasHighThreshold Integer32, hwORCfgChannel0AGCMode INTEGER, hwORCfgChannel1AGCMode INTEGER, hwORRuninfoChannel0AGCMode INTEGER, hwORRuninfoChannel1AGCMode INTEGER, hwORRFCH1PowerValue Integer32, hwORRFCH1PowerAlarmState INTEGER, hwOTCH1WaveLength Integer32, hwOTCfgOpticalWorkMode INTEGER, hwOTRuninfoOpticalWorkMode INTEGER, hwOTCH0RFAttValue Integer32, hwOTCH1RFAttValue Integer32, hwORCh0OnlineState INTEGER, hwORCh1OnlineState INTEGER, hwOTCh0OnlineState INTEGER, hwOTCh1OnlineState INTEGER, hwONCfgOpticalWorkMode INTEGER, hwONRuninfoOpticalWorkMode INTEGER, hwOTCh0RuninfoOpticalLowPassFilter Integer32, hwOTCh1RuninfoOpticalLowPassFilter Integer32, hwONSmartCapability BITS, hwORRFPowerChangeThreshold Integer32, hwORCHN0RFPowerReferenceValue Integer32, hwORCHN0RFPowerChangeValue Integer32, hwORCHN1RFPowerReferenceValue Integer32, hwORCHN1RFPowerChangeValue Integer32, hwORCH0CurrentInputVoltage1 Integer32, hwORCH0CurrentInputVoltage2 Integer32, hwORCH1CurrentInputVoltage1 Integer32, hwORCH1CurrentInputVoltage2 Integer32, hwOTCH0CurrentInputVoltage1 Integer32, hwOTCH0CurrentInputVoltage2 Integer32, hwOTCH1CurrentInputVoltage1 Integer32, hwOTCH1CurrentInputVoltage2 Integer32 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.1 hwONCOMState OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2), shutdown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The state of Optical node The Optical node can be used only when it is online. Options: 1.online(1) - indicates that Optical state is online 2.offline(2) - indicates that Optical state is offline 3.shutdown(3) - indicates that Optical state is shutdown " ::= { hwOpticalNodeEntry 1 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.2 hwONModelNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The model number of Optical node invalid(zero-length) " ::= { hwOpticalNodeEntry 2 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.3 hwONHardwareVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The hard version of Optical node invalid(zero-length) " ::= { hwOpticalNodeEntry 3 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.4 hwONSoftwareVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The software version of Optical node invalid(zero-length) " ::= { hwOpticalNodeEntry 4 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.5 hwONProductDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0 | 8)) MAX-ACCESS read-only STATUS current DESCRIPTION " The product date of Optical node field octets contents range ----- ------ -------- ----- 1 1-4 year 0..65536 2 5-6 month 1..12 3 7-8 day 1..31 " ::= { hwOpticalNodeEntry 5 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.6 hwOROpticalPowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This is the power of the only channel for the single-channel optical receiver. This is the power of channel 0 for the dual-channel optical receiver. Its unit is dbm,its real accuracy is 0.01. SNMP uses it which has been enlarged 100 by host. user uses it which has been lessened 100 by SNMP. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 6 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.7 hwOROpticalPowerAlarmState OBJECT-TYPE SYNTAX INTEGER { normal(1), low(2), high(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " This is the power alarm state of the only channel for the single-channel optical receiver. This is the power alarm state of channel 0 for the dual-channel optical receiver. The Optical receiver can be used only when it is normal. Options: 1.normal(1) - indicates that Optical power alarm state is normal 2.low(2) - indicates that Optical power alarm state is low 3.high(3) - indicates that Optical power alarm state is high " ::= { hwOpticalNodeEntry 7 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.8 hwOROpticalPowerLowThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the low power threshold of the only channel for the single-channel optical receiver. This is the low power threshold of channel 0 for the dual-channel optical receiver. Its unit is dbm,its real accuracy is 0.01. SNMP uses it which has been enlarged 100 by host. user uses it which has been lessened 100 by SNMP. Its real range is -10dbm~3dbm,mib range is -1000dbm~300dbm. " ::= { hwOpticalNodeEntry 8 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.9 hwOROpticalPowerHighThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the high power threshold of the only channel for the single-channel optical receiver. This is the high power threshold of channel 0 for the dual-channel optical receiver. Its unit is dbm,its real accuracy is 0.01. SNMP uses it which has been enlarged 100 by host. user uses it which has been lessened 100 by SNMP. Its real range is -10dbm~3dbm,mib range is -1000dbm~300dbm. " ::= { hwOpticalNodeEntry 9 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.10 hwOROpticalAGCStart OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the start value of the AGC range of the only channel for the single-channel optical receiver. This is the start value of the AGC range of channel 0 for the dual-channel optical receiver. Its unit is dBm,its real range is -4dBm~3dBm. " ::= { hwOpticalNodeEntry 10 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.11 hwORRFPowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The RF power value of Optical receiver. When the dual-channel optical receiver works in combination mode, this leaf indicates the RF power of channel 0. Its unit is dBmV,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 11 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.12 hwORRFPowerAlarmState OBJECT-TYPE SYNTAX INTEGER { normal(1), low(2), high(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The RF power alarm state of Optical receiver. When the dual-channel optical receiver works in combination mode, this leaf indicates the RF power alarm status of channel 0. The Optical receiver can be used only when it is normal. Options: 1.normal(1) - indicates that RF power alarm state is normal 2.low(2) - indicates that RF power alarm state is low 3.high(3) - indicates that RF power alarm state is high " ::= { hwOpticalNodeEntry 12 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.13 hwORRFPowerLowThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The RF power low threshold of Optical receiver Its unit is dBmV,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. Lower threshold for RF alarms(optical transceiver modularization:-15; other optical transceiver:25;unit:dBmV). Its real range is -15dBmV~70dBmV,mib range is -150dBmV~700dBmV. " ::= { hwOpticalNodeEntry 13 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.14 hwORRFPowerHighThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The RF power high threshold of Optical receiver Its unit is dBmV,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. Its real range is -15dBmV~70dBmV,mib range is -150dBmV~700dBmV. " ::= { hwOpticalNodeEntry 14 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.15 hwORRFAttValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The RF ATT value of Optical receiver Its unit is db. Its range is 0db~10db. " ::= { hwOpticalNodeEntry 15 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.16 hwORRFSwitch OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " The RF switch of Optical receiver The Optical receiver can be used only when it is on. Options: 1.off(1) - indicates that RF Switch state is off 2.on(2) - indicates that RF Switch state is on " ::= { hwOpticalNodeEntry 16 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.17 hwONBarcode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The barcode of Optical node invalid(zero-length) " ::= { hwOpticalNodeEntry 17 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.18 hwONCurrentInputVoltage1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The current input voltage1 of Optical node. Its unit is V,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. The current input voltage1 is positive voltage. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 18 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.19 hwONCurrentInputVoltage2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The current input voltage2 of Optical node. Its unit is V,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. The current input voltage2 is positive voltage. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 19 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.20 hwORAGCRange OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " This is the AGC range of the only channel for the single-channel optical receiver. This is the AGC range of channel 0 for the dual-channel optical receiver. " ::= { hwOpticalNodeEntry 20 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.21 hwOTOpticalOutputPowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This is the power of the only channel for the single-channel optical transmitter. This is the power of channel 0 for the dual-channel optical transmitter. Its unit is 0.01dbm. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 21 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.22 hwOTOpticalOutputPowerAlarmState OBJECT-TYPE SYNTAX INTEGER { normal(1), low(2), high(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " This is the power alarm state of the only channel for the single-channel optical transmitter. This is the power alarm state of channel 0 for the dual-channel optical transmitter. The optical transmitter can be used only when it is normal. Options: 1.normal(1) - The optical power alarm state is normal when the transmit power value between low alarm threshold and high alarm threshold. 2.low(2) - The optical power alarm state is low when the transmit power value is lower than the low alarm threshold. 3.high(3) - The optical power alarm state is high when the transmit power value is higher than the high alarm threshold. " ::= { hwOpticalNodeEntry 22 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.23 hwOTOpticalOutputPowerLowThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the low power threshold of the only channel for the single-channel optical transmitter. This is the low power threshold of channel 0 for the dual-channel optical transmitter. The alarm is produced when the optical transmit power value is lower than this value. Its unit is 0.01dbm. Its range is 0dbm~6dbm. " ::= { hwOpticalNodeEntry 23 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.24 hwOTOpticalOutputPowerHighThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the high power threshold of the only channel for the single-channel optical transmitter. This is the high power threshold of channel 0 for the dual-channel optical transmitter. The alarm is produced when the optical transmit power value is higher than this value. Its unit is 0.01dbm. Its range is 0dbm~6dbm. " ::= { hwOpticalNodeEntry 24 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.25 hwOTBiasValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This is the bias current value of the only channel for the single-channel optical transmitter. This is the bias current value of channel 0 for the dual-channel optical transmitter. Its unit is mA,its normal range is 1mA~100mA. invalid(-1) " ::= { hwOpticalNodeEntry 25 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.26 hwOTBiasAlarmState OBJECT-TYPE SYNTAX INTEGER { normal(1), low(2), high(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " This is the bias current alarm state of the only channel for the single-channel optical transmitter. This is the bias current alarm state of channel 0 for the dual-channel optical transmitter. The optical transmitter can be used only when it is normal. Options: 1.normal(1) - The bias current alarm state is normal when the bias current value between low alarm threshold and high alarm threshold. 2.low(2) - The bias current alarm state is low when the bias current value is lower than the low alarm threshold. 3.high(3) - The bias current alarm state is high when the bias current value is higher than the high alarm threshold. " ::= { hwOpticalNodeEntry 26 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.27 hwOTBiasLowThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the low bias current threshold of the only channel for the single-channel optical transmitter. This is the low bias current threshold of channel 0 for the dual-channel optical transmitter. The alarm is produced when the bias current value is lower than this value. Its unit is mA. Its range is 1mA~100mA,default value is 10mA. " ::= { hwOpticalNodeEntry 27 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.28 hwOTBiasHighThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the high bias current threshold of the only channel for the single-channel optical transmitter. This is the high bias current threshold of channel 0 for the dual-channel optical transmitter. The alarm is produced when the bias current value is higher than this value. Its unit is mA. Its range is 1mA~100mA,default value is 60mA. " ::= { hwOpticalNodeEntry 28 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.29 hwOTWaveLength OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The wave length of Optical transmitter. Its unit is nm. Its value is 1310nm or 1550nm or 1610nm. invalid(-1) " ::= { hwOpticalNodeEntry 29 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.30 hwOROpticalWorkMode OBJECT-TYPE SYNTAX INTEGER { forcechannel0(1), forcechannel1(2), preferchannel0(3), preferchannel1(4), combiner(5) } MAX-ACCESS read-write STATUS current DESCRIPTION " The protect-switch channel policy of dual-channel optical receiver. Options: 1.force-channel0(1) - Force channel 0 as working channel, and forbid switching channel. 2.force-channel1(2) - Force channel 1 as working channel, and forbid switching channel. 3.prefer-channel0(3) - Prefer channel 0 as working channel priority and permit switch when channel 0 failed. 4.prefer-channel1(4) - Prefer channel 1 as working channel priority and permit switch when channel 1 failed. 5.combiner(5) - Combination mode. Both channel 0 and channel 1 are working. " ::= { hwOpticalNodeEntry 30 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.31 hwOROpticalActiveChannel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The working channel of dual-channel optical receiver. invalid(-1). " ::= { hwOpticalNodeEntry 31 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.32 hwOROpticalCH1PowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This is the power of channel 1 for the dual-channel optical receiver. Its unit is dbm,its real accuracy is 0.01. SNMP uses it which has been enlarged 100 by host. user uses it which has been lessened 100 by SNMP. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 32 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.33 hwOROpticalCH1PowerAlarmState OBJECT-TYPE SYNTAX INTEGER { normal(1), low(2), high(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " This is the power alarm state of channel 1 for the dual-channel optical receiver. The optical receiver can be used only when it is normal. Options: 1.normal(1) - indicates that Optical power alarm state is normal 2.low(2) - indicates that Optical power alarm state is low 3.high(3) - indicates that Optical power alarm state is high " ::= { hwOpticalNodeEntry 33 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.34 hwOROpticalCH1PowerLowThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the low power threshold of channel 1 for the dual-channel optical receiver. Its unit is dbm,its real accuracy is 0.01. SNMP uses it which has been enlarged 100 by host. user uses it which has been lessened 100 by SNMP. Its real range is -10dbm~3dbm,mib range is -1000dbm~300dbm. " ::= { hwOpticalNodeEntry 34 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.35 hwOROpticalCH1PowerHighThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the high power threshold of channel 1 for the dual-channel optical receiver. Its unit is dbm,its real accuracy is 0.01. SNMP uses it which has been enlarged 100 by host. user uses it which has been lessened 100 by SNMP. Its real range is -10dbm~3dbm,mib range is -1000dbm~300dbm. " ::= { hwOpticalNodeEntry 35 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.36 hwOROpticalCH1AGCStart OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the start value of the AGC range of channel 1 for the dual-channel optical receiver. Its unit is dBm,its real range is -4dBm~3dBm. " ::= { hwOpticalNodeEntry 36 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.37 hwORAGCCH1Range OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " This is the AGC range of channel 1 for the dual-channel optical receiver. " ::= { hwOpticalNodeEntry 37 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.38 hwORType OBJECT-TYPE SYNTAX INTEGER { opticalreceiver(1), opticalreceivertransmitter(2), dualchannelopticalreceiver(3), opticalreceiverdualchannelopticaltransmitter(4), dualchannelopticalreceiverdualchannelopticaltransmitter(5), dualchannelopticalreceiveropticaltransmitter(6), opticaltransmitter(7), dualchannelopticaltransmitter(8), invalid(99) } MAX-ACCESS read-only STATUS current DESCRIPTION " The optical type of optical node. Options: 1.optical-receiver(1) 2.optical-receiver/optical-transmitter(2) 3.dual-channel optical-receiver(3) 4.optical-receiver/dual-channel optical-transmitter(4) 5.dual-channel optical-receiver/dual-channel optical-transmitter(5) 6.dual-channel optical-receiver/optical-transmitter(6) 7.optical-transmitter(7) 8.dual-channel optical-transmitter(8) 9.invalid type(99) " ::= { hwOpticalNodeEntry 38 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.39 hwOTOpticalOutputCH1PowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This is the power of channel 1 for the dual-channel optical transmitter. Its unit is dbm,its real accuracy is 0.01. SNMP uses it which has been enlarged 100 by host. user uses it which has been lessened 100 by SNMP. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 39 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.40 hwOTOpticalOutputCH1PowerAlarmState OBJECT-TYPE SYNTAX INTEGER { normal(1), low(2), high(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " This is the power alarm state of channel 1 for the dual-channel optical transmitter. The optical transmitter can be used only when it is normal. Options: 1.normal(1) - indicates that Optical power alarm state is normal 2.low(2) - indicates that Optical power alarm state is low 3.high(3) - indicates that Optical power alarm state is high " ::= { hwOpticalNodeEntry 40 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.41 hwOTOpticalOutputCH1PowerLowThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the low power threshold of channel 1 for the dual-channel optical transmitter. Its unit is dbm,its real accuracy is 0.01. SNMP uses it which has been enlarged 100 by host. user uses it which has been lessened 100 by SNMP. Its range is 0dbm~6dbm. " ::= { hwOpticalNodeEntry 41 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.42 hwOTOpticalOutputCH1PowerHighThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the high power threshold of channel 1 for the dual-channel optical transmitter. Its unit is dbm,its real accuracy is 0.01. SNMP uses it which has been enlarged 100 by host. user uses it which has been lessened 100 by SNMP. Its range is 0dbm~6dbm. " ::= { hwOpticalNodeEntry 42 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.43 hwOTCH1BiasValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This is the bias current value of channel 1 for the dual-channel optical transmitter. Its unit is mA,its normal range is 1mA~100mA. invalid(-1) " ::= { hwOpticalNodeEntry 43 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.44 hwOTCH1BiasAlarmState OBJECT-TYPE SYNTAX INTEGER { normal(1), low(2), high(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " This is the bias current alarm state of channel 1 for the dual-channel optical transmitter. The optical transmitter can be used only when it is normal. Options: 1.normal(1) - The bias current alarm state is normal when the bias current value between low alarm threshold and high alarm threshold. 2.low(2) - The bias current alarm state is low when the bias current value is lower than the low alarm threshold. 3.high(3) - The bias current alarm state is high when the bias current value is higher than the high alarm threshold. " ::= { hwOpticalNodeEntry 44 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.45 hwOTCH1BiasLowThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the low bias current threshold of channel 1 for the dual-channel optical transmitter. The alarm is produced when the bias current value is lower than this value. Its unit is mA. Its range is 1mA~100mA,default value is 10mA. " ::= { hwOpticalNodeEntry 45 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.46 hwOTCH1BiasHighThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the high bias current threshold of channel 1 for the dual-channel optical transmitter. The alarm is produced when the bias current value is higher than this value. Its unit is mA. Its range is 1mA~100mA,default value is 60mA. " ::= { hwOpticalNodeEntry 46 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.47 hwORCfgChannel0AGCMode OBJECT-TYPE SYNTAX INTEGER { off(2), minus6to2dBm(3), minus4to2dBm(4), minus2to2dBm(5) } MAX-ACCESS read-write STATUS current DESCRIPTION " Indicates the configuration information about the AGC gain on channel 0 for the optical receiver. Options: 1.off(2) - indicates that AGC gain is off 2.minus6to2dBm(3) - indicates that the range of AGC gain is -6dBm to +2dBm 3.minus4to2dBm(4) - indicates that the range of AGC gain is -4dBm to +2dBm 4.minus2to2dBm(5) - indicates that the range of AGC gain is -2dBm to +2dBm default is minus6to2dBm(3). " ::= { hwOpticalNodeEntry 47 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.48 hwORCfgChannel1AGCMode OBJECT-TYPE SYNTAX INTEGER { off(2), minus6to2dBm(3), minus4to2dBm(4), minus2to2dBm(5) } MAX-ACCESS read-write STATUS current DESCRIPTION " Indicates the configuration information about the AGC gain on channel 1 for the optical receiver. Options: 1.off(2) - indicates that AGC gain is off 2.minus6to2dBm(3) - indicates that the range of AGC gain is -6dBm to +2dBm 3.minus4to2dBm(4) - indicates that the range of AGC gain is -4dBm to +2dBm 4.minus2to2dBm(5) - indicates that the range of AGC gain is -2dBm to +2dBm default is minus6to2dBm(3). " ::= { hwOpticalNodeEntry 48 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.49 hwORRuninfoChannel0AGCMode OBJECT-TYPE SYNTAX INTEGER { invalid(1), off(2), minus6to2dBm(3), minus4to2dBm(4), minus2to2dBm(5) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the running information about the AGC gain on channel 0 for the optical receiver. Options: 1.invalid(1) - indicates that AGC gain is not supported for the optical receiver or the optical receiver is not online 2.off(2) - indicates that AGC gain is off 3.minus6to2dBm(3) - indicates that the range of AGC gain is -6dBm to +2dBm 4.minus4to2dBm(4) - indicates that the range of AGC gain is -4dBm to +2dBm 5.minus2to2dBm(5) - indicates that the range of AGC gain is -2dBm to +2dBm default is minus6to2dBm(3).s " ::= { hwOpticalNodeEntry 49 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.50 hwORRuninfoChannel1AGCMode OBJECT-TYPE SYNTAX INTEGER { invalid(1), off(2), minus6to2dBm(3), minus4to2dBm(4), minus2to2dBm(5) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the running information about the AGC gain on channel 1 for the optical receiver. Options: 1.invalid(1) - indicates that AGC gain is not supported for the optical receiver or the optical receiver is not online 2.off(2) - indicates that AGC gain is off 3.minus6to2dBm(3) - indicates that the range of AGC gain is -6dBm to +2dBm 4.minus4to2dBm(4) - indicates that the range of AGC gain is -4dBm to +2dBm 5.minus2to2dBm(5) - indicates that the range of AGC gain is -2dBm to +2dBm default is minus6to2dBm(3). " ::= { hwOpticalNodeEntry 50 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.51 hwORRFCH1PowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " When the dual-channel optical receiver works in combination mode, this leaf takes effect and it indicates the RF power of channel 1. Its unit is dBmV,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 51 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.52 hwORRFCH1PowerAlarmState OBJECT-TYPE SYNTAX INTEGER { normal(1), low(2), high(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " When the dual-channel optical receiver works in combination mode, this leaf takes effect and it indicates the RF power alarm status of channel 1. The Optical receiver can be used only when it is normal. Options: 1.normal(1) - indicates that RF power alarm state is normal 2.low(2) - indicates that RF power alarm state is low 3.high(3) - indicates that RF power alarm state is high " ::= { hwOpticalNodeEntry 52 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.53 hwOTCH1WaveLength OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The wave length of channel 1 for the Optical transmitter . Its unit is nm. Its value is 1310nm or 1550nm or 1610nm. invalid(-1) " ::= { hwOpticalNodeEntry 53 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.54 hwOTCfgOpticalWorkMode OBJECT-TYPE SYNTAX INTEGER { singleSGsingleTX(2), singleSGdoubleTX(3), doubleSGdoubleTX(4) } MAX-ACCESS read-write STATUS current DESCRIPTION " Indicates the configuration information about the work mode for the optical transmitter. Options: 2.singleSGsingleTX(2) - indicates the working mode is single SG(service group), single TX(optical transmitter) 3.singleSGdoubleTX(3) - indicates the working mode is single SG(service group), double TX(optical transmitter) 4.doubleSGdoubleTX(4) - indicates the working mode is double SG(service group), double TX(optical transmitter) default is doubleSGdoubleTX(4). " ::= { hwOpticalNodeEntry 54 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.55 hwOTRuninfoOpticalWorkMode OBJECT-TYPE SYNTAX INTEGER { invalid(1), singleSGsingleTX(2), singleSGdoubleTX(3), doubleSGdoubleTX(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the running information about the work mode for the optical transmitter. 1.invalid(1) - indicates the working mode is not supported for the optical transmitter or the optical transmitter is not online 2.singleSGsingleTX(2) - indicates the working mode is single SG(service group), single TX(optical transmitter) 3.singleSGdoubleTX(3) - indicates the working mode is single SG(service group), double TX(optical transmitter) 4.doubleSGdoubleTX(4) - indicates the working mode is double SG(service group), double TX(optical transmitter) default is doubleSGdoubleTX(4). " ::= { hwOpticalNodeEntry 55 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.56 hwOTCH0RFAttValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the rf attenuation current value of channel 0 for the dual-channel optical transmitter. Its unit is dB,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. Its range is 0.0dB~20.0dB. invalid(-1) " ::= { hwOpticalNodeEntry 56 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.57 hwOTCH1RFAttValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the rf attenuation current value of channel 1 for the dual-channel optical transmitter. Its unit is dB,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. Its range is 0.0dB~20.0dB. invalid(-1) " ::= { hwOpticalNodeEntry 57 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.58 hwORCh0OnlineState OBJECT-TYPE SYNTAX INTEGER { normal(1), offline(2), fault(3), config(4), autoload(5), manualshutdown(6), mismatch(7) } MAX-ACCESS read-only STATUS current DESCRIPTION " The state of channel 0 for the optical receiver. Options: 1.normal(1) - indicates that optical receiver channel 0 is normal 2.offline(2) - indicates that optical receiver channel 0 is offline 3.fault(3) - indicates that optical receiver channel 0 is fault 4.config(4) - indicates that optical receiver channel 0 is config 5.autoload(5) - indicates that optical receiver channel 0 is autoload 6.manualshutdown(6) - indicates that optical receiver channel 0 is manualshutdown 7.mismatch(7) - indicates that optical receiver channel 0 is mismatch " ::= { hwOpticalNodeEntry 58 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.59 hwORCh1OnlineState OBJECT-TYPE SYNTAX INTEGER { normal(1), offline(2), fault(3), config(4), autoload(5), manualshutdown(6), mismatch(7) } MAX-ACCESS read-only STATUS current DESCRIPTION " The state of channel 1 for the optical receiver. Options: 1.normal(1) - indicates that optical receiver channel 1 is normal 2.offline(2) - indicates that optical receiver channel 1 is offline 3.fault(3) - indicates that optical receiver channel 1 is fault 4.config(4) - indicates that optical receiver channel 1 is config 5.autoload(5) - indicates that optical receiver channel 1 is autoload 6.manualshutdown(6) - indicates that optical receiver channel 1 is manualshutdown 7.mismatch(7) - indicates that optical receiver channel 1 is mismatch " ::= { hwOpticalNodeEntry 59 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.60 hwOTCh0OnlineState OBJECT-TYPE SYNTAX INTEGER { normal(1), offline(2), fault(3), config(4), autoload(5), manualshutdown(6), mismatch(7) } MAX-ACCESS read-only STATUS current DESCRIPTION " The state of channel 0 for the optical transmitter. Options: 1.normal(1) - indicates that optical transmitter channel 0 is normal 2.offline(2) - indicates that optical transmitter channel 0 is offline 3.fault(3) - indicates that optical transmitter channel 0 is fault 4.config(4) - indicates that optical transmitter channel 0 is config 5.autoload(5) - indicates that optical transmitter channel 0 is autoload 6.manualshutdown(6) - indicates that optical transmitter channel 0 is manualshutdown 7.mismatch(7) - indicates that optical transmitter channel 0 is mismatch " ::= { hwOpticalNodeEntry 60 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.61 hwOTCh1OnlineState OBJECT-TYPE SYNTAX INTEGER { normal(1), offline(2), fault(3), config(4), autoload(5), manualshutdown(6), mismatch(7) } MAX-ACCESS read-only STATUS current DESCRIPTION " The state of channel 1 for the optical transmitter. Options: 1.normal(1) - indicates that optical transmitter channel 1 is normal 2.offline(2) - indicates that optical transmitter channel 1 is offline 3.fault(3) - indicates that optical transmitter channel 1 is fault 4.config(4) - indicates that optical transmitter channel 1 is config 5.autoload(5) - indicates that optical transmitter channel 1 is autoload 6.manualshutdown(6) - indicates that optical transmitter channel 1 is manualshutdown 7.mismatch(7) - indicates that optical transmitter channel 1 is mismatch " ::= { hwOpticalNodeEntry 61 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.62 hwONCfgOpticalWorkMode OBJECT-TYPE SYNTAX INTEGER { invalid(1), singleRXdoubleTX(2), doubleRXsingleTX(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " Indicates the configuration information about the work mode for the optical node. Options: 1.invalid(1) - indicates the working mode is not supported for the optical node or the optical node is not online 2.singleRXdoubleTX(2) - indicates the working mode is single RX(optical receiver), double TX(optical transmitter) 3.doubleRXsingleTX(3) - indicates the working mode is double RX(optical receiver), single TX(optical transmitter) default is singleRXdoubleTX(2). " ::= { hwOpticalNodeEntry 62 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.63 hwONRuninfoOpticalWorkMode OBJECT-TYPE SYNTAX INTEGER { invalid(1), singleRXdoubleTX(2), doubleRXsingleTX(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the configuration information about the work mode for the optical node. Options: 1.invalid(1) - indicates the working mode is not supported for the optical node or the optical node is not online 2.singleRXdoubleTX(2) - indicates the working mode is single RX(optical receiver), double TX(optical transmitter) 3.doubleRXsingleTX(3) - indicates the working mode is double RX(optical receiver), single TX(optical transmitter) default is singleRXdoubleTX(2). " ::= { hwOpticalNodeEntry 63 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.64 hwOTCh0RuninfoOpticalLowPassFilter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The low pass filter of channel 0 for the Optical transmitter . Its unit is MHz. Its value is 42MHz or 65MHz or 85MHz or 204MHz. invalid(-1) " ::= { hwOpticalNodeEntry 64 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.65 hwOTCh1RuninfoOpticalLowPassFilter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The low pass filter of channel 1 for the Optical transmitter . Its unit is MHz. Its value is 42MHz or 65MHz or 85MHz or 204MHz. invalid(-1) " ::= { hwOpticalNodeEntry 65 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.66 hwONSmartCapability OBJECT-TYPE SYNTAX BITS { setOTCHRFAttValue(0), setONCfgOpticalWorkMode(1), setOTCfgOpticalWorkMode(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " This MIB node is used to query the function of the optical node, which is represented by bits. Functions of each bit are as follows: 1: setOTCHRFAttValue(0) - indicates whether the RF attenuation of the optical transmitter channel is supported. 2: setONCfgOpticalWorkMode(1) - indicates whether the multiplexing mode of the optical receiver or transmitter node is supported. 3: setOTCfgOpticalWorkMode(2) - indicates whether the protection mode of the optical transmitter is supported. From left to right, each bit indicates whether the function is supported. If this bit is 1, the function is supported. If this bit is 0, the function is not supported. " ::= { hwOpticalNodeEntry 66 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.67 hwORRFPowerChangeThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The RF power change threshold of Optical receiver Its unit is dBmV,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. Its real range is 3dBmV~15dBmV,mib range is 30dBmV~150dBmV. " ::= { hwOpticalNodeEntry 67 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.68 hwORCHN0RFPowerReferenceValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The RF power reference value of Optical receiver. When the dual-channel optical receiver works in combination mode, this leaf indicates the RF power reference value of channel 0. Its unit is dBmV,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. invalid: 0x7fffffff." ::= { hwOpticalNodeEntry 68 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.69 hwORCHN0RFPowerChangeValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The RF power change value of Optical receiver. When the dual-channel optical receiver works in combination mode, this leaf indicates the RF power change value of channel 0. Its unit is dBmV,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. invalid: 0x7fffffff." ::= { hwOpticalNodeEntry 69 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.70 hwORCHN1RFPowerReferenceValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " When the dual-channel optical receiver works in combination mode, this leaf takes effect and it indicates the RF power reference value of channel 1. Its unit is dBmV,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. invalid: 0x7fffffff." ::= { hwOpticalNodeEntry 70 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.71 hwORCHN1RFPowerChangeValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " When the dual-channel optical receiver works in combination mode, this leaf takes effect and it indicates the RF power change value of channel 1. Its unit is dBmV,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. invalid: 0x7fffffff." ::= { hwOpticalNodeEntry 71 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.72 hwORCH0CurrentInputVoltage1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The RX CH0 current input voltage1 of Optical node. Its unit is V,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. The RX CH0 current input voltage1 is positive voltage. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 72 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.73 hwORCH0CurrentInputVoltage2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The RX CH0 current input voltage2 of Optical node. Its unit is V,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. The RX CH0 current input voltage2 is positive voltage. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 73 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.74 hwORCH1CurrentInputVoltage1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The RX CH1 current input voltage1 of Optical node. Its unit is V,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. The RX CH1 current input voltage1 is positive voltage. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 74 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.75 hwORCH1CurrentInputVoltage2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The RX CH1 current input voltage2 of Optical node. Its unit is V,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. The RX CH1 current input voltage2 is positive voltage. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 75 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.76 hwOTCH0CurrentInputVoltage1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The TX CH0 current input voltage1 of Optical node. Its unit is V,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. The TX CH0 current input voltage1 is positive voltage. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 76 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.77 hwOTCH0CurrentInputVoltage2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The TX CH0 current input voltage2 of Optical node. Its unit is V,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. The TX CH0 current input voltage2 is positive voltage. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 77 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.78 hwOTCH1CurrentInputVoltage1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The TX CH1 current input voltage1 of Optical node. Its unit is V,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. The TX CH1 current input voltage1 is positive voltage. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 78 } -- 1.3.6.1.4.1.2011.6.1.1.7.1.79 hwOTCH1CurrentInputVoltage2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The TX CH1 current input voltage2 of Optical node. Its unit is V,its real accuracy is 0.1. SNMP uses it which has been enlarged 10 by host. user uses it which has been lessened 10 by SNMP. The TX CH1 current input voltage2 is positive voltage. invalid: 0x7fffffff. " ::= { hwOpticalNodeEntry 79 } -- 1.3.6.1.4.1.2011.6.1.1.8 hwOpticalPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF HwOpticalPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The indexes of this entry are hwFrameIndex and hwOpticalChnIndex. The index of this table is hwFrameIndex that comes from hwFrameTable. " ::= { hwEnvironmentMon 8 } -- 1.3.6.1.4.1.2011.6.1.1.8.1 hwOpticalPowerEntry OBJECT-TYPE SYNTAX HwOpticalPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The indexes of this entry are hwFrameIndex and hwOpticalChnIndex. The index of this table is hwFrameIndex that comes from hwFrameTable. " INDEX { hwFrameIndex, hwOpticalChnIndex } ::= { hwOpticalPowerTable 1 } HwOpticalPowerEntry ::= SEQUENCE { hwOpticalChnIndex Integer32, hwOpticalPowerValue OCTET STRING, hwOpticalBiasValue Integer32 } -- 1.3.6.1.4.1.2011.6.1.1.8.1.1 hwOpticalChnIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The channel id of optical node. " ::= { hwOpticalPowerEntry 1 } -- 1.3.6.1.4.1.2011.6.1.1.8.1.2 hwOpticalPowerValue OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The optical power value of optical node Its unit is dbm,its real accuracy is 0.01. " ::= { hwOpticalPowerEntry 2 } -- 1.3.6.1.4.1.2011.6.1.1.8.1.3 hwOpticalBiasValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The optical Bias value of optical node Its unit is mA. " ::= { hwOpticalPowerEntry 3 } -- 1.3.6.1.4.1.2011.6.1.1.9 hwFanUnitTable OBJECT-TYPE SYNTAX SEQUENCE OF HwFanUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Fan unit table. The index of this table are hwEnvEmuIndex that comes from hwEnvironmentInfoTable and hwFanUnitIndex. hwEnvEmuIndex is the index of the monitoring unit whose monitoring type is temperature control unit, and hwFanUnitIndex is the index of fan unit that is monitored by the fan. " ::= { hwEnvironmentMon 9 } -- 1.3.6.1.4.1.2011.6.1.1.9.1 hwFanUnitEntry OBJECT-TYPE SYNTAX HwFanUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Fan unit table. The index of this table are hwEnvEmuIndex that comes from hwEnvironmentInfoTable and hwFanUnitIndex. hwEnvEmuIndex is the index of the monitoring unit whose monitoring type is temperature control unit, and hwFanUnitIndex is the index of fan unit that is monitored by the fan. " INDEX { hwEnvEmuIndex, hwFanUnitIndex } ::= { hwFanUnitTable 1 } HwFanUnitEntry ::= SEQUENCE { hwFanUnitIndex Integer32, hwFanUnitSpeed Integer32 } -- 1.3.6.1.4.1.2011.6.1.1.9.1.1 hwFanUnitIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The index of fan unit. " ::= { hwFanUnitEntry 1 } -- 1.3.6.1.4.1.2011.6.1.1.9.1.2 hwFanUnitSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The speed of fan unit Its unit is round per minute, invalid: -1. " ::= { hwFanUnitEntry 2 } -- 1.3.6.1.4.1.2011.6.1.1.10 hwSirenTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSirenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " siren config table" ::= { hwEnvironmentMon 10 } -- 1.3.6.1.4.1.2011.6.1.1.10.1 hwSirenEntry OBJECT-TYPE SYNTAX HwSirenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "siren config table" INDEX { hwEnvEmuIndex } ::= { hwSirenTable 1 } HwSirenEntry ::= SEQUENCE { hwSirenSwitch INTEGER, hwSirenHowlerDelay Integer32, hwSirenHowlerDuration Integer32, hwSirenSlientDuration Integer32 } -- 1.3.6.1.4.1.2011.6.1.1.10.1.1 hwSirenSwitch OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), invalid(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION " enabe and disable the siren. 1:enable 2:disable -1:invalid " DEFVAL { disable } ::= { hwSirenEntry 1 } -- 1.3.6.1.4.1.2011.6.1.1.10.1.2 hwSirenHowlerDelay OBJECT-TYPE SYNTAX Integer32 (0..1440) MAX-ACCESS read-write STATUS current DESCRIPTION "the howler-delay of the siren.The default value is 30,the unit is minute. invalid: -1." DEFVAL { 30 } ::= { hwSirenEntry 2 } -- 1.3.6.1.4.1.2011.6.1.1.10.1.3 hwSirenHowlerDuration OBJECT-TYPE SYNTAX Integer32 (0..1440) MAX-ACCESS read-write STATUS current DESCRIPTION "the howler-duration of the siren.The default value is 3,the unit is minute. invalid: -1." DEFVAL { 3 } ::= { hwSirenEntry 3 } -- 1.3.6.1.4.1.2011.6.1.1.10.1.4 hwSirenSlientDuration OBJECT-TYPE SYNTAX Integer32 (0..1440) MAX-ACCESS read-write STATUS current DESCRIPTION "the slient-duration of the siren.The default value is 60,the unit is minute. invalid(-1)." DEFVAL { 60 } ::= { hwSirenEntry 4 } -- 1.3.6.1.4.1.2011.6.1.1.11 hwElockTable OBJECT-TYPE SYNTAX SEQUENCE OF HwElockEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Electronic lock table. The index of this table are hwEnvEmuIndex that comes from hwEnvironmentInfoTable and hwElockIndex. hwEnvEmuIndex is the index of the monitoring unit whose monitoring type is door lock unit, and hwElockIndex is the index of door lock that is smu. " ::= { hwEnvironmentMon 11 } -- 1.3.6.1.4.1.2011.6.1.1.11.1 hwElockEntry OBJECT-TYPE SYNTAX HwElockEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Electronic lock table. The index of this table are hwEnvEmuIndex that comes from hwEnvironmentInfoTable and hwElockIndex. hwEnvEmuIndex is the index of the monitoring unit whose monitoring type is electric lock unit, and hwElockIndex is the index of electronic lock. " INDEX { hwEnvEmuIndex, hwElockIndex } ::= { hwElockTable 1 } HwElockEntry ::= SEQUENCE { hwElockIndex Integer32, hwElockName DisplayString, hwElockEnableFlag INTEGER, hwElockCommStatus INTEGER, hwElockCtrStatus INTEGER } -- 1.3.6.1.4.1.2011.6.1.1.11.1.1 hwElockIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The index of electronic lock. " ::= { hwElockEntry 1 } -- 1.3.6.1.4.1.2011.6.1.1.11.1.2 hwElockName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Electronic lock type: Ammeter-Compartment, Device-Compartment, Device1-Compartment, Device2-Compartment, HEX-Compartment, MDF-Compartment, MDF1-Compartment, MDF2-Compartment, " ::= { hwElockEntry 2 } -- 1.3.6.1.4.1.2011.6.1.1.11.1.3 hwElockEnableFlag OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), invalid(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable/Disable a electronic lock. Enable(1), Disable(2), invalid(-1) " ::= { hwElockEntry 3 } -- 1.3.6.1.4.1.2011.6.1.1.11.1.4 hwElockCommStatus OBJECT-TYPE SYNTAX INTEGER { unconfigured(2), normal(9), faulty(10), invalid(-1) } MAX-ACCESS read-only STATUS current DESCRIPTION " The state of the communication of the electric lock with the host. unconfigured(2):The electronic has not been configured. normal(9):The communication of the electronic with the host is normal. faulty(10):The communication of the electronic with the host is abnormal. invalid: -1. " ::= { hwElockEntry 4 } -- 1.3.6.1.4.1.2011.6.1.1.11.1.5 hwElockCtrStatus OBJECT-TYPE SYNTAX INTEGER { statusOpen(1), statusClose(0), statusNoElock(255), invalid(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION " The status of electric lock. statusOpen(1):The electronic door lock is open. statusClose(0):The electronic door lock is closed. statusNoElock(255):The electronic has not been enabled. invalid: -1. " ::= { hwElockEntry 5 } -- 1.3.6.1.4.1.2011.6.1.1.12 hwElockRightTable OBJECT-TYPE SYNTAX SEQUENCE OF HwElockRightEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Electronic right card table. The index of this table are hwEnvEmuIndex that comes from hwEnvironmentInfoTable and hwElockRightCardId. hwEnvEmuIndex is the index of the monitoring unit whose monitoring type is door lock unit, and hwElockRightCardId is the ID of right card. " ::= { hwEnvironmentMon 12 } -- 1.3.6.1.4.1.2011.6.1.1.12.1 hwElockRightEntry OBJECT-TYPE SYNTAX HwElockRightEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Electronic right card table. The index of this table are hwEnvEmuIndex that comes from hwEnvironmentInfoTable and hwElockRightCardId. hwEnvEmuIndex is the index of the monitoring unit whose monitoring type is door lock unit, and hwElockRightCardId is the index of door lock. " INDEX { hwEnvEmuIndex, hwElockRightCardId } ::= { hwElockRightTable 1 } HwElockRightEntry ::= SEQUENCE { hwElockRightCardId Integer32, hwElockRightElockIndexMask OCTET STRING, hwElockRightRowStatus RowStatus, hwElockRightStartTime OCTET STRING, hwElockRightExpireTime OCTET STRING } -- 1.3.6.1.4.1.2011.6.1.1.12.1.1 hwElockRightCardId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The id of eletronic lock right card. " ::= { hwElockRightEntry 1 } -- 1.3.6.1.4.1.2011.6.1.1.12.1.2 hwElockRightElockIndexMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0 | 3)) MAX-ACCESS read-write STATUS current DESCRIPTION " 000:indicates that the right card can not open any elock. 001:indicates that the right card can open the first elock. 010:indicates that the right card can open the second elock. 100:indicates that the right card can open the third elock. 011:indicates that the right card can open the first and the second elock. 101:indicates that the right card can open the first and the third elock. 110:indicates that the right card can open the second and the third elock. 111:indicates that the right card can open all elocks. " ::= { hwElockRightEntry 2 } -- 1.3.6.1.4.1.2011.6.1.1.12.1.3 hwElockRightRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " Indicates the row status. To create an right card, set this leaf to createAndGo(4). To delete an right card, set this leaf to destroy(6). When this leaf is queried, the value is fixed to active(1). Options: 1. active(1) -indicates the query operation. 2. createAndGo(4) -indicates creating an right card. 3. destroy(6) -indicates deleting an right card. " ::= { hwElockRightEntry 3 } -- 1.3.6.1.4.1.2011.6.1.1.12.1.4 hwElockRightStartTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0 | 14)) MAX-ACCESS read-write STATUS current DESCRIPTION " The start time of the door card authority. field octets contents range ----- ------ -------- ----- 1 1-4 year 0..9999 2 5-6 month 1..12 3 7-8 day 1..31 4 9-10 hour 0..24 5 11-12 minute 0..60 6 13-14 second 0..60 For example, if the start time is 2017-12-20 10:20:30, the input o output is 20171220102030" ::= { hwElockRightEntry 4 } -- 1.3.6.1.4.1.2011.6.1.1.12.1.5 hwElockRightExpireTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0 | 14)) MAX-ACCESS read-write STATUS current DESCRIPTION " The expire time of the door card authority. field octets contents range ----- ------ -------- ----- 1 1-4 year 0..9999 2 5-6 month 1..12 3 7-8 day 1..31 4 9-10 hour 0..24 5 11-12 minute 0..60 6 13-14 second 0..60 For example, if the expire time is 2017-12-30 10:20:30, the input o output is 20171230102030" ::= { hwElockRightEntry 5 } -- 1.3.6.1.4.1.2011.6.1.1.13 hwOpticalModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF HwOpticalModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The indexes of this table are hwFrameIndex, hwOpticalModuleType, hwOpticalChnIndex and hwOpticalDevType. The index hwFrameIndex comes from hwFrameTable. " ::= { hwEnvironmentMon 13 } -- 1.3.6.1.4.1.2011.6.1.1.13.1 hwOpticalModuleEntry OBJECT-TYPE SYNTAX HwOpticalModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The indexes of this entry are hwFrameIndex, hwOpticalModuleType, hwOpticalChnIndex and hwOpticalDevType. The index hwFrameIndex comes from hwFrameTable. " INDEX { hwFrameIndex, hwOpticalModuleType, hwOpticalChnIndex } ::= { hwOpticalModuleTable 1 } HwOpticalModuleEntry ::= SEQUENCE { hwOpticalModuleType OCTET STRING, hwOpticalDevType OCTET STRING } -- 1.3.6.1.4.1.2011.6.1.1.13.1.1 hwOpticalModuleType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The module type of optical node. " ::= { hwOpticalModuleEntry 1 } -- 1.3.6.1.4.1.2011.6.1.1.13.1.2 hwOpticalDevType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The dev type of optical node. " ::= { hwOpticalModuleEntry 2 } -- 1.3.6.1.4.1.2011.6.1.2 snmpTrapsDef OBJECT IDENTIFIER ::= { hwEnvironment 2 } -- 1.3.6.1.4.1.2011.6.1.2.0 emmsnmpTraps OBJECT IDENTIFIER ::= { snmpTrapsDef 0 } -- 1.3.6.1.4.1.2011.6.1.2.0.1 envCommAlarm NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex } STATUS current DESCRIPTION " The communication alarm of environment monitoring board, reporting the environment monitoring unit ID. This trap message is reported when the communication between the emu and control board is fault. " ::= { emmsnmpTraps 1 } -- 1.3.6.1.4.1.2011.6.1.2.0.2 envCommAlarmResume NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex } STATUS current DESCRIPTION " The communication alarm recovery of the environment monitoring, reporting the environment monitoring unit ID. This trap message is reported when the communication between the emu and control board resumes. " ::= { emmsnmpTraps 2 } -- 1.3.6.1.4.1.2011.6.1.2.0.3 anaFaultAlarm NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex, hwAnaChannelIndex } STATUS current DESCRIPTION " The alarm recovery of the analog exception, reporting the environment monitoring unit ID. This trap message is reported when there is an analog exception in emu. " ::= { emmsnmpTraps 3 } -- 1.3.6.1.4.1.2011.6.1.2.0.4 anaFaultAlarmResume NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex, hwAnaChannelIndex } STATUS current DESCRIPTION " The alarm recovery of the analog exception, reporting the environment monitoring unit ID. This trap message is reported when the analog exception recovery in emu. " ::= { emmsnmpTraps 4 } -- 1.3.6.1.4.1.2011.6.1.2.0.5 anaTooHighAlarm NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex, hwAnaChannelIndex } STATUS current DESCRIPTION " The alarm of too high an analog, reporting the environment monitoring unit ID and the channel ID of the analog sensor. This trap message is reported when an analog value is too high. " ::= { emmsnmpTraps 5 } -- 1.3.6.1.4.1.2011.6.1.2.0.6 anaTooHighAlarmResume NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex, hwAnaChannelIndex } STATUS current DESCRIPTION " The alarm of too high analog resume, reporting the environment monitoring unit ID. This trap message is reported when an analog value returns to normal range from the high value. " ::= { emmsnmpTraps 6 } -- 1.3.6.1.4.1.2011.6.1.2.0.7 anaTooLowAlarm NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex, hwAnaChannelIndex } STATUS current DESCRIPTION " The alarm of too low an analog, reporting the environment monitoring unit ID and the channel ID of the analog sensor. This trap message is reported when an analog value is too low. " ::= { emmsnmpTraps 7 } -- 1.3.6.1.4.1.2011.6.1.2.0.8 anaTooLowAlarmResume NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex, hwAnaChannelIndex } STATUS current DESCRIPTION " The alarm of too low an analog, reporting the environment monitoring unit ID. This trap message is reported when an analog value returns to normal range from the low value. " ::= { emmsnmpTraps 8 } -- 1.3.6.1.4.1.2011.6.1.2.0.9 controlAlarm NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex, hwControlOutIndex } STATUS current DESCRIPTION " The control alarm, reporting the environment monitoring unit ID. This trap message is reported when emu control operation fails. " ::= { emmsnmpTraps 9 } -- 1.3.6.1.4.1.2011.6.1.2.0.10 controlAlarmResume NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex, hwControlOutIndex } STATUS current DESCRIPTION " The control alarm, reporting the environment monitoring unit ID. This trap message is reported when emu control operation resumes. " ::= { emmsnmpTraps 10 } -- 1.3.6.1.4.1.2011.6.1.2.0.11 digtalMeasureAlarm NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex, hwDigChannelIndex } STATUS current DESCRIPTION " The digital measure alarm, reporting the environment monitoring unit ID and the channel ID of the digital sensor. This trap message is reported when emu measure operation fails. " ::= { emmsnmpTraps 11 } -- 1.3.6.1.4.1.2011.6.1.2.0.12 digtaleasureAlarmResume NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex, hwDigChannelIndex } STATUS current DESCRIPTION " The digital measure alarm recovery, reporting the environment monitoring unit ID and the channel ID of the digital sensor. This trap message is reported when emu measure operation resumes. " ::= { emmsnmpTraps 12 } -- 1.3.6.1.4.1.2011.6.1.2.0.13 fanExistsAlarm NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex } STATUS current DESCRIPTION " Fan nonexistance alarm. This trap message is reported when there is no fan device connected to control board. " ::= { emmsnmpTraps 13 } -- 1.3.6.1.4.1.2011.6.1.2.0.14 fanExistsAlarmResume NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex } STATUS current DESCRIPTION " Fan nonexistance alarm recovery. This trap message is reported when there is a fan device connected to control board. " ::= { emmsnmpTraps 14 } -- 1.3.6.1.4.1.2011.6.1.2.0.15 fanRunStateAlarm NOTIFICATION-TYPE OBJECTS { hwEnvEmuIndex } STATUS current DESCRIPTION " Fan running status alarm. This trap message is reported when the fan run state gets abnormal. " ::= { emmsnmpTraps 15 } -- 1.3.6.1.4.1.2011.6.1.3 envConformance OBJECT IDENTIFIER ::= { hwEnvironment 3 } -- 1.3.6.1.4.1.2011.6.1.3.1 envCompliances OBJECT IDENTIFIER ::= { envConformance 1 } -- 1.3.6.1.4.1.2011.6.1.3.2 envGroups OBJECT IDENTIFIER ::= { envConformance 2 } -- 1.3.6.1.4.1.2011.6.1.4 hwEnvironTraps OBJECT IDENTIFIER ::= { hwEnvironment 4 } -- 1.3.6.1.4.1.2011.6.1.4.1 hwEnvironCommonTraps OBJECT IDENTIFIER ::= { hwEnvironTraps 1 } -- 1.3.6.1.4.1.2011.6.1.4.1.0 hwEnvironCommonTrapsPrefix OBJECT IDENTIFIER ::= { hwEnvironCommonTraps 0 } -- 1.3.6.1.4.1.2011.6.1.4.1.1 hwEmmEmuAutofindTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwEnvEmuType } STATUS current DESCRIPTION "The agent generates this trap when a new EMU autofind. " ::= { hwEnvironCommonTrapsPrefix 1 } -- 1.3.6.1.4.1.2011.6.1.4.2 hwEnvironAlarmTraps OBJECT IDENTIFIER ::= { hwEnvironTraps 2 } -- 1.3.6.1.4.1.2011.6.1.4.2.1 hwEnvironEmuAlarmTraps OBJECT IDENTIFIER ::= { hwEnvironAlarmTraps 1 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0 hwEnvironEmuAlarmTrapsPrefix OBJECT IDENTIFIER ::= { hwEnvironEmuAlarmTraps 0 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.1 hwEmmEmufailTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwEnvEmuType, hwEnvBoardName } STATUS current DESCRIPTION "The agent generates this trap when the communication of the EMU with the host is abnormal. " ::= { hwEnvironEmuAlarmTrapsPrefix 1 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.2 hwEmmEmuRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwEnvEmuType, hwEnvBoardName } STATUS current DESCRIPTION "The agent generates this trap when the communication of the EMU with the host recovers. " ::= { hwEnvironEmuAlarmTrapsPrefix 2 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.3 hwEmmEmuHardwareFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when the following two faults occurs: 1. Power fault, which involves the following three scenarios: 1) Only one power board is installed on the MSAN. 2) Two power boards are detected on the device but only one power board is connected to the power supply. 3) Two power boards are detected on the device but one of them is faulty and cannot supply power. 2. Read temperature fault, which occurs when the fan temperature sensor is faulty. " ::= { hwEnvironEmuAlarmTrapsPrefix 3 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.4 hwEmmEmuHardwareRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when the a Hardware exception Recover " ::= { hwEnvironEmuAlarmTrapsPrefix 4 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.5 hwEmmEmuAutofindFailTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvAutofindNodeId, hwEnvAutofindEmuType, hwEnvAutofindBoardName, hwFailureCause } STATUS current DESCRIPTION "The agent generates this trap when the emu autofind fail. " ::= { hwEnvironEmuAlarmTrapsPrefix 5 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.6 hwEmmEmuFanStateTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwFanStatus } STATUS current DESCRIPTION "The agent generates this trap when the fan is not configured or fails. " ::= { hwEnvironEmuAlarmTrapsPrefix 6 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.7 hwOpticalNodeFailTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex } STATUS current DESCRIPTION "The agent generates this trap when the communication of the OpticalNode with the host is abnormal. " ::= { hwEnvironEmuAlarmTrapsPrefix 7 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.8 hwOpticalNodeRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex } STATUS current DESCRIPTION "The agent generates this trap when the communication of the OpticalNode with the host recovers. " ::= { hwEnvironEmuAlarmTrapsPrefix 8 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.9 hwOpticalReceiverPowerFailTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOROpticalPowerValueTrap } STATUS current DESCRIPTION "The agent generates this trap when the optical power of OpticalReceiver is abnormal. " ::= { hwEnvironEmuAlarmTrapsPrefix 9 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.10 hwOpticalReceiverPowerRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOROpticalPowerValueTrap } STATUS current DESCRIPTION "The agent generates this trap when the optical power of OpticalReceiver recovers to normal range. " ::= { hwEnvironEmuAlarmTrapsPrefix 10 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.11 hwOpticalReceiverRFPowerFailTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwORRFPowerValueTrap } STATUS current DESCRIPTION "The agent generates this trap when the RF power of OpticalReceiver is abnormal. " ::= { hwEnvironEmuAlarmTrapsPrefix 11 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.12 hwOpticalReceiverRFPowerRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwORRFPowerValueTrap } STATUS current DESCRIPTION "The agent generates this trap when the RF power of OpticalReceiver recovers to normal range. " ::= { hwEnvironEmuAlarmTrapsPrefix 12 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.13 hwOpticalTransmitterPowerFailTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOTOpticalOutputPowerValueTrap } STATUS current DESCRIPTION "The agent generates this trap when the optical power of OpticalTransmitter is abnormal. " ::= { hwEnvironEmuAlarmTrapsPrefix 13 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.14 hwOpticalTransmitterPowerRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOTOpticalOutputPowerValueTrap } STATUS current DESCRIPTION "The agent generates this trap when the optical power of OpticalTransmitter recovers to normal range. " ::= { hwEnvironEmuAlarmTrapsPrefix 14 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.15 hwOpticalTransmitterBiasFailTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOTBiasValue } STATUS current DESCRIPTION "The agent generates this trap when the optical bias of OpticalTransmitter is abnormal. " ::= { hwEnvironEmuAlarmTrapsPrefix 15 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.16 hwOpticalTransmitterBiasRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOTBiasValue } STATUS current DESCRIPTION "The agent generates this trap when the optical bias of OpticalTransmitter recovers to normal range. " ::= { hwEnvironEmuAlarmTrapsPrefix 16 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.17 hwOpticalDualChnProtectSwitchTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex } STATUS current DESCRIPTION "The agent generates this trap when the dual-channel optical occur protect-switch channel. " ::= { hwEnvironEmuAlarmTrapsPrefix 17 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.18 hwOpticalReceiverDualChnPowerFailTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOpticalChnIndex, hwOpticalPowerValue } STATUS current DESCRIPTION "The agent generates this trap when the optical power of dual-channel OpticalReceiver is abnormal. " ::= { hwEnvironEmuAlarmTrapsPrefix 18 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.19 hwOpticalReceiverDualChnPowerRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOpticalChnIndex, hwOpticalPowerValue } STATUS current DESCRIPTION "The agent generates this trap when the optical power of dual-channel OpticalReceiver recovers to normal range. " ::= { hwEnvironEmuAlarmTrapsPrefix 19 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.20 hwModuleOpticalTransmitterPowerFailTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOpticalChnIndex, hwOpticalPowerValue } STATUS current DESCRIPTION "The agent generates this trap when the optical power of OpticalTransmitter is abnormal. " ::= { hwEnvironEmuAlarmTrapsPrefix 20 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.21 hwModuleOpticalTransmitterPowerRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOpticalChnIndex, hwOpticalPowerValue } STATUS current DESCRIPTION "The agent generates this trap when the optical power of OpticalTransmitter recovers to normal range. " ::= { hwEnvironEmuAlarmTrapsPrefix 21 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.22 hwModuleOpticalTransmitterBiasRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOpticalChnIndex, hwOpticalBiasValue } STATUS current DESCRIPTION "The agent generates this trap when the optical bias of OpticalTransmitter recovers to normal range. " ::= { hwEnvironEmuAlarmTrapsPrefix 22 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.23 hwModuleOpticalTransmitterBiasFailTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOpticalChnIndex, hwOpticalBiasValue } STATUS current DESCRIPTION "The agent generates this trap when the optical bias of OpticalTransmitter is abnormal. " ::= { hwEnvironEmuAlarmTrapsPrefix 23 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.24 hwModuleOpticalCombinerRFPowerFailTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOpticalChnIndex, hwORRFPowerValueTrap } STATUS current DESCRIPTION "The agent generates this trap when the dual-channel OpticalReceiver use the combiner protect-switch channel policy and the RF power of dual-channel OpticalReceiver is abnormal. " ::= { hwEnvironEmuAlarmTrapsPrefix 24 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.25 hwModuleOpticalCombinerRFPowerRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOpticalChnIndex, hwORRFPowerValueTrap } STATUS current DESCRIPTION "The agent generates this trap when the dual-channel OpticalReceiver use the combiner protect-switch channel policy and the RF power of dual-channel OpticalReceiver recovers to normal range . " ::= { hwEnvironEmuAlarmTrapsPrefix 25 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.26 hwEmmDoorLockCommFailTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwElockIndex } STATUS current DESCRIPTION "The agent generates this trap when the door lock cannot communicate with the main board. " ::= { hwEnvironEmuAlarmTrapsPrefix 26 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.27 hwEmmDoorLockCommRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwElockIndex } STATUS current DESCRIPTION "The agent generates this trap when the door lock recover to communicate with the main board. " ::= { hwEnvironEmuAlarmTrapsPrefix 27 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.28 hwEmmDoorLockAbnormalUnlockTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwElockIndex } STATUS current DESCRIPTION "The agent generates this trap when the the door lock is abnormal unlocked. " ::= { hwEnvironEmuAlarmTrapsPrefix 28 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.29 hwEmmDoorLockAbnormalUnlockRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwElockIndex } STATUS current DESCRIPTION "The agent generates this trap when the the door lock recover to the normal state. " ::= { hwEnvironEmuAlarmTrapsPrefix 29 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.30 hwOpticalModuleTypeMismatchTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOpticalModuleType, hwOpticalChnIndex, hwOpticalDevType } STATUS current DESCRIPTION "The agent generates this trap when the type of the inserted optical receiver or transmitter does not match that supported by the slot. " ::= { hwEnvironEmuAlarmTrapsPrefix 30 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.31 hwOpticalModuleTypeMismatchRestoreTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOpticalModuleType, hwOpticalChnIndex, hwOpticalDevType } STATUS current DESCRIPTION "The agent generates this trap when mismatch between the type of the optical receiver or transmitter and that supported by the slot is rectified. " ::= { hwEnvironEmuAlarmTrapsPrefix 31 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.32 hwEmmDoorLockOpenLockTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwElockIndex, hwUnlockMode, hwElockRightCardId, hwUnlockSN, hwUnlockTime } STATUS current DESCRIPTION "The agent generates this trap when the electronic lock is opened. " ::= { hwEnvironEmuAlarmTrapsPrefix 32 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.33 hwOpticalReceiverRfChangeFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOpticalChnIndex, hwORRFPowerValueTrap, hwORRFPowerRefValueTrap, hwORRFPowerChangeValueTrap } STATUS current DESCRIPTION "The agent generates this trap when the RF output power change exceeds the alarm threshold. " ::= { hwEnvironEmuAlarmTrapsPrefix 33 } -- 1.3.6.1.4.1.2011.6.1.4.2.1.0.34 hwOpticalModuleAbsenceTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwOpticalModuleType, hwOpticalChnIndex, hwOpticalDevType } STATUS current DESCRIPTION "The agent generates this trap when the optical module plug out. " ::= { hwEnvironEmuAlarmTrapsPrefix 34 } -- 1.3.6.1.4.1.2011.6.1.4.2.2 hwEnvironAnaAlarmTraps OBJECT IDENTIFIER ::= { hwEnvironAlarmTraps 2 } -- 1.3.6.1.4.1.2011.6.1.4.2.2.0 hwEnvironAnaAlarmTrapsPrefix OBJECT IDENTIFIER ::= { hwEnvironAnaAlarmTraps 0 } -- 1.3.6.1.4.1.2011.6.1.4.2.2.0.1 hwEmmAnaUnnamedFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwAnaChannelIndex, hwEnvEmuType, hwAnaName } STATUS current DESCRIPTION "The agent generates this trap when an unnamed analog alarm occurs. " ::= { hwEnvironAnaAlarmTrapsPrefix 1 } -- 1.3.6.1.4.1.2011.6.1.4.2.2.0.2 hwEmmAnaUnnamedRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwAnaChannelIndex, hwEnvEmuType, hwAnaName } STATUS current DESCRIPTION "The agent generates this trap when an unnamed analog alarm recovers. " ::= { hwEnvironAnaAlarmTrapsPrefix 2 } -- 1.3.6.1.4.1.2011.6.1.4.2.2.0.3 hwEmmAnaTempFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwAnaChannelIndex, hwEnvEmuType, hwAnaName } STATUS current DESCRIPTION "The agent generates this trap when the analog temperature alarm occurs. " ::= { hwEnvironAnaAlarmTrapsPrefix 3 } -- 1.3.6.1.4.1.2011.6.1.4.2.2.0.4 hwEmmAnaTempRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwAnaChannelIndex, hwEnvEmuType, hwAnaName } STATUS current DESCRIPTION "The agent generates this trap when the analog temperature alarm recovers. " ::= { hwEnvironAnaAlarmTrapsPrefix 4 } -- 1.3.6.1.4.1.2011.6.1.4.2.2.0.5 hwEmmAnaHumyFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwAnaChannelIndex, hwEnvEmuType, hwAnaName } STATUS current DESCRIPTION "The agent generates this trap when the analog humidity alarm occurs. " ::= { hwEnvironAnaAlarmTrapsPrefix 5 } -- 1.3.6.1.4.1.2011.6.1.4.2.2.0.6 hwEmmAnaHumyRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwAnaChannelIndex, hwEnvEmuType, hwAnaName } STATUS current DESCRIPTION "The agent generates this trap when the analog humidity alarm recovers. " ::= { hwEnvironAnaAlarmTrapsPrefix 6 } -- 1.3.6.1.4.1.2011.6.1.4.2.2.0.0.7 hwEmmAnaVoltFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwAnaChannelIndex, hwEnvEmuType, hwAnaName } STATUS current DESCRIPTION "The agent generates this trap when the analog voltage alarm occurs. " ::= { hwEnvironAnaAlarmTrapsPrefix 7 } -- 1.3.6.1.4.1.2011.6.1.4.2.2.0.8 hwEmmAnaVoltRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwAnaChannelIndex, hwEnvEmuType, hwAnaName } STATUS current DESCRIPTION "The agent generates this trap when the analog voltage alarm recovers. " ::= { hwEnvironAnaAlarmTrapsPrefix 8 } -- 1.3.6.1.4.1.2011.6.1.4.2.2.0.9 hwEmmAnaCurrentFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwAnaChannelIndex, hwEnvEmuType, hwAnaName } STATUS current DESCRIPTION "The agent generates this trap when the analog current alarm occurs. " ::= { hwEnvironAnaAlarmTrapsPrefix 9 } -- 1.3.6.1.4.1.2011.6.1.4.2.2.0.10 hwEmmAnaCurrentRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwAnaChannelIndex, hwEnvEmuType, hwAnaName } STATUS current DESCRIPTION "The agent generates this trap when the analog current alarm recovers. " ::= { hwEnvironAnaAlarmTrapsPrefix 10 } -- 1.3.6.1.4.1.2011.6.1.4.2.3 hwEnvironDigAlarmTraps OBJECT IDENTIFIER ::= { hwEnvironAlarmTraps 3 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0 hwEnvironDigAlarmTrapsPrefix OBJECT IDENTIFIER ::= { hwEnvironDigAlarmTraps 0 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.1 hwEmmDigFanBlockFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when the fan is blocked. " ::= { hwEnvironDigAlarmTrapsPrefix 1 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.2 hwEmmDigFanBlockRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when the fan is recovered from block. " ::= { hwEnvironDigAlarmTrapsPrefix 2 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.3 hwEmmDigFanTempHighFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when the temperature of fan is too high. " ::= { hwEnvironDigAlarmTrapsPrefix 3 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.4 hwEmmDigFanTempHighRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when the temperature of fan recover from too high. " ::= { hwEnvironDigAlarmTrapsPrefix 4 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.5 hwEmmDigUnnamedFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when a unnamed digital fault occurs. " ::= { hwEnvironDigAlarmTrapsPrefix 5 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.6 hwEmmDigUnnamedRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when a unnamed digital recovers. " ::= { hwEnvironDigAlarmTrapsPrefix 6 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.7 hwEmmDigOutputswitchFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when Output switch digital fault occurs. " ::= { hwEnvironDigAlarmTrapsPrefix 7 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.8 hwEmmDigOutputswitchRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when Output switch digital recovers. " ::= { hwEnvironDigAlarmTrapsPrefix 8 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.11 hwEmmDigAcvolFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The AC voltage is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 11 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.12 hwEmmDigAcvolRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The AC voltage recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 12 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.13 hwEmmDigAcswitchFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The AC switch is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 13 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.14 hwEmmDigAcswitchRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The AC switch recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 14 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.15 hwEmmDigBattvolFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The batt vol is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 15 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.16 hwEmmDigBattvolRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The batt vol recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 16 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.17 hwEmmDigBattfuseFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The battery fuse is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 17 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.18 hwEmmDigBattfuseRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The battery fuse recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 18 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.19 hwEmmDigLoadfuseFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The load fuse is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 19 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.20 hwEmmDigLoadfuseRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The load fuse recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 20 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.21 hwEmmDigRectifierFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Rectifier is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 21 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.22 hwEmmDigRectifierRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Rectifier recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 22 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.23 hwEmmDigDcpowerFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The dc-power is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 23 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.24 hwEmmDigDcpowerRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The dc-power recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 24 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.25 hwEmmDigRoomdoorFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Roomdoor is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 25 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.26 hwEmmDigRoomdoorRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Roomdoor recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 26 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.27 hwEmmDigTheftFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Roomdoor is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 27 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.28 hwEmmDigTheftRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Roomdoor recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 28 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.29 hwEmmDigWiringFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The WIRING is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 29 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.30 hwEmmDigWiringRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The WIRING recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 30 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.31 hwEmmDigFanFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The FAN is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 31 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.32 hwEmmDigFanRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The FAN recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 32 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.33 hwEmmDigFireFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Fire is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 33 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.34 hwEmmDigFireRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Fire recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 34 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.35 hwEmmDigFogFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Fog is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 35 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.36 hwEmmDigFogRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Fog recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 36 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.37 hwEmmDigWaterFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Water is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 37 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.38 hwEmmDigWaterRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Water recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 38 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.39 hwEmmDigDieselFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Diesel is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 39 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.40 hwEmmDigDieselRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Diesel recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 40 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.41 hwEmmDigSmellFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Smell is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 41 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.42 hwEmmDigSmellRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Smell recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 42 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.43 hwEmmDigAirconditionFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Air condition is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 43 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.44 hwEmmDigAirconditionRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The Air condition recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 44 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.45 hwEmmDigArrsterFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The arrester is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 45 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.46 hwEmmDigArrsterRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The arrester recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 46 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.47 hwEmmDigDcvolFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The DC VOL is out of the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 47 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.48 hwEmmDigDcvolRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when The DC VOL recovers to the normal range. " ::= { hwEnvironDigAlarmTrapsPrefix 48 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.49 hwEmmFanCriticalBlockFaultTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when more than two fans are blocked. " ::= { hwEnvironDigAlarmTrapsPrefix 49 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.50 hwEmmFanCriticalBlockRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when the critical multi-fan blocking recovers. " ::= { hwEnvironDigAlarmTrapsPrefix 50 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.51 hwEmmDigitalSwitchOpenTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when the 48V input switch is closed. " ::= { hwEnvironDigAlarmTrapsPrefix 51 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.52 hwEmmDigitalSwitchCloseTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when the 48V input switch is opened. " ::= { hwEnvironDigAlarmTrapsPrefix 52 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.53 hwEmmDigFanSpeedAbnormalTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when the fan rotation speed deteriorates. " ::= { hwEnvironDigAlarmTrapsPrefix 53 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.54 hwEmmDigFanSpeedRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when fan rotation speed deterioration recovers. " ::= { hwEnvironDigAlarmTrapsPrefix 54 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.55 hwEmmDigAcInputPowerOffTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when the AC power is off. " ::= { hwEnvironDigAlarmTrapsPrefix 55 } -- 1.3.6.1.4.1.2011.6.1.4.2.3.0.56 hwEmmDigAcInputPowerRecoverTrap NOTIFICATION-TYPE OBJECTS { hwFrameIndex, hwEnvEmuIndex, hwDigChannelIndex, hwEnvEmuType, hwDigChannelName } STATUS current DESCRIPTION "The agent generates this trap when the AC input power recovers. " ::= { hwEnvironDigAlarmTrapsPrefix 56 } -- 1.3.6.1.4.1.2011.6.1.5 hwEmmTrapVbOids OBJECT IDENTIFIER ::= { hwEnvironment 5} -- 1.3.6.1.4.1.2011.6.1.5.1 hwFanStatus OBJECT-TYPE SYNTAX INTEGER { notconfig(1), failure(2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The status of the fan. Options: 1.notconfig(1) -The status of the fan is notconfig 2.failure(2) -The status of the fan is fail " ::= { hwEmmTrapVbOids 1 } -- 1.3.6.1.4.1.2011.6.1.5.2 hwFailureCause OBJECT-TYPE SYNTAX INTEGER { fullemu(1), emunotsupportautofind(2), shelfnotsupport(3), rpsrisfull(4), vescisfull(5), fanisfull(6) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The reason of the auto-finding failure: Options: 1.fullemu(1) -No enough EMU IDs are available 2.emunotsupportautofind(2) -The EMU does not support the auto discovery function 3.shelfnotsupport(3) -The shelf does not support the EMU of this type 4.rpsrisfull(4) -RPSR of this frame already full 5.vescisfull(5) -VESC of this frame already full 6.fanisfull(6) -FAN of this frame already full " ::= { hwEmmTrapVbOids 2 } -- 1.3.6.1.4.1.2011.6.1.5.3 hwEnvAutofindNodeId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The NodeId of the auto-found EMU. " ::= { hwEmmTrapVbOids 3 } -- 1.3.6.1.4.1.2011.6.1.5.4 hwEnvAutofindEmuType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The type of the auto-found EMU. " ::= { hwEmmTrapVbOids 4 } -- 1.3.6.1.4.1.2011.6.1.5.5 hwEnvAutofindBoardName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The board name of the auto-found EMU. " ::= { hwEmmTrapVbOids 5 } -- 1.3.6.1.4.1.2011.6.1.5.6 hwOROpticalPowerValueTrap OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The optical power value of Optical receiver. " ::= { hwEmmTrapVbOids 6 } -- 1.3.6.1.4.1.2011.6.1.5.7 hwORRFPowerValueTrap OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The RF power value of Optical receiver. " ::= { hwEmmTrapVbOids 7 } -- 1.3.6.1.4.1.2011.6.1.5.8 hwOTOpticalOutputPowerValueTrap OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The optical power value of Optical transmitter. " ::= { hwEmmTrapVbOids 8 } -- 1.3.6.1.4.1.2011.6.1.5.9 hwUnlockMode OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The mode of opening the lock. " ::= { hwEmmTrapVbOids 9 } -- 1.3.6.1.4.1.2011.6.1.5.10 hwUnlockSN OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The series number of the unlocked event. " ::= { hwEmmTrapVbOids 10 } -- 1.3.6.1.4.1.2011.6.1.5.11 hwUnlockTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The time when the unlocked event happened. " ::= { hwEmmTrapVbOids 11 } -- 1.3.6.1.4.1.2011.6.1.5.12 hwORRFPowerRefValueTrap OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The RF power reference value of optical receiver. " ::= { hwEmmTrapVbOids 12 } -- 1.3.6.1.4.1.2011.6.1.5.13 hwORRFPowerChangeValueTrap OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The RF power change value of optical receiver. " ::= { hwEmmTrapVbOids 13 } END