-- ============================================================================ -- Copyright (C) 2022 by HUAWEI TECHNOLOGIES. All rights reserved. -- Description: This mib is used for defining huawei's energy management MIB objects -- Reference: None -- Version: V2.09 -- ============================================================================ HUAWEI-ENERGYMNGT-MIB DEFINITIONS ::= BEGIN IMPORTS IpAddress, Integer32, Counter64, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP FROM SNMPv2-CONF InetAddressType, InetAddress FROM INET-ADDRESS-MIB DisplayString, DateAndTime, TruthValue, RowStatus FROM SNMPv2-TC huaweiUtility FROM HUAWEI-MIB ; hwEnergyMngt MODULE-IDENTITY LAST-UPDATED "202202280000Z" ORGANIZATION "Huawei Technologies Co.,Ltd." CONTACT-INFO "Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com Email: support@huawei.com " DESCRIPTION "huawei energy management MIB." REVISION "202202280000Z" DESCRIPTION "V2.09 Add hwChassisPowerMngt." REVISION "202112030000Z" DESCRIPTION "V2.08 Add hwTypicalPower, hwBoardTypicalPower." REVISION "201801150000Z" DESCRIPTION "V2.07 Modify the description ." REVISION "201712060000Z" DESCRIPTION "V2.056 Modify the description of hwEnergySavingMethodIndex." REVISION "201706210000Z" DESCRIPTION "V2.05. Modify the description of hwBoardName and hwBoardType ." REVISION "201511110000Z" DESCRIPTION "V2.04. Add enum of hwEnergySavingMode:optimal." REVISION "201505300000Z" DESCRIPTION "V2.03. Add enum of hwEnergySavingMode:optimal. This is a draft version." REVISION "201401230000Z" DESCRIPTION "V2.02. Add hwEnergyDevId, hwEnergyDevChangeToSleep. This is a draft version." REVISION "201107010000Z" DESCRIPTION "V0.114. Add hwPoEType, hwPSEPower. Modify FTPC table. This is a draft version." REVISION "201103141530Z" DESCRIPTION "V0.113, add hwEnergyFtpcIpv4TransMode and hwEnergyFtpcTransMode. This is a draft version." REVISION "201103140000Z" DESCRIPTION "V0.112, modify hwEnergyFtpcTransFileIpv4Table and hwEnergyFtpcTransFileTable. This is a draft version." REVISION "201103100000Z" DESCRIPTION "V0.111, add hwEnergyFtpcObjects, including hwEnergyFtpcTransFileIpv4Table and hwEnergyFtpcTransFileTable. This is a draft version." REVISION "201102100000Z" DESCRIPTION "V0.11, add hwEnergySavingDescReqMode." REVISION "201008060000Z" DESCRIPTION "V0.10, modify hwBoardIndex." REVISION "201008050000Z" DESCRIPTION "V0.09, modify hwBoardType." REVISION "201008030000Z" DESCRIPTION "V0.08, modify watt to milliwatt. Modify enumeration of hwEnergySavingMode. Add boardType and boardDescription." REVISION "201007120000Z" DESCRIPTION "V0.08, modify hwPowerStatPeriod." REVISION "201007070000Z" DESCRIPTION "V0.06, modify hwPowerStatPeriod." REVISION "201006290000Z" DESCRIPTION "V0.05, modify hwEnergySavingMethodEnable value list. Delete hwEnergySavingParameterTable first index 'hwEnergySavingMethodIndex'" REVISION "201006230000Z" DESCRIPTION "V0.05, modify hwEnergySavingCapabilityMngtEntry, modify hwEnergySavingMethodTable" REVISION "201006180000Z" DESCRIPTION "V0.04, modify hwEnergySavingCapabilityMngtEntry" REVISION "201006170000Z" DESCRIPTION "V0.03, modify description for all MIB table" REVISION "201006080000Z" DESCRIPTION "V0.02, add hwEnergySavingMethodEntry, add hwEnergySavingCapabilityMngt" REVISION "201005240000Z" DESCRIPTION "V0.01 mib initial" ::= { huaweiUtility 157 } -- -- Node definitions -- -- 1.1 hwSysPowerMgnt OBJECT IDENTIFIER ::= { hwEnergyMngt 1 } -- 1.1.1 hwPowerConsumption OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the accumulated power consumption of an NE." ::= { hwSysPowerMgnt 1 } -- 1.1.2 hwPowerStatPeriod OBJECT-TYPE SYNTAX INTEGER { fifteenMinutes(1), thirtyMinutes(2), oneHour(3), oneDay(4), oneWeek(5), oneMonth(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the update period of power consumption data." DEFVAL {oneHour} ::= { hwSysPowerMgnt 2 } -- 1.1.3 hwAveragePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the average power consumption of an NE within a measurement period." ::= { hwSysPowerMgnt 3 } -- 1.1.4 hwRatedPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the rated power consumption of an NE." ::= { hwSysPowerMgnt 4 } -- 1.1.5 hwThresholdOfPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the NE power consumption threshold." ::= { hwSysPowerMgnt 5 } -- 1.1.6 hwCurrentPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the current power consumption of an NE." ::= { hwSysPowerMgnt 6 } -- 1.1.7 hwPoEType OBJECT-TYPE SYNTAX INTEGER { pse(1), pd(2), noPoe(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "powered type: PSE(1): power supplier. PD(2): powered deivce. noPoe(255): not PSE or PD" ::= { hwSysPowerMgnt 7 } -- 1.1.8 hwPSEPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The output power(milliwatt) by a PSE. For a non-PSE device, the value is zero." ::= { hwSysPowerMgnt 8 } -- 1.1.9 hwTypicalPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the typical consumption of an NE." ::= { hwSysPowerMgnt 9 } -- 1.2 hwBoardPowerMngt OBJECT IDENTIFIER ::= { hwEnergyMngt 2 } -- 1.2.1 hwBoardPowerMngtTable OBJECT-TYPE SYNTAX SEQUENCE OF HwBoardPowerMngtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes board-level power consumption attributes." ::= { hwBoardPowerMngt 1 } -- 1.2.1.1 hwBoardPowerMngtEntry OBJECT-TYPE SYNTAX HwBoardPowerMngtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry of hwBoardPowerMngtTable." INDEX { hwBoardIndex } ::= { hwBoardPowerMngtTable 1 } HwBoardPowerMngtEntry ::= SEQUENCE { hwBoardIndex Integer32, hwBoardType DisplayString, hwBoardName DisplayString, hwBoardCurrentPower Integer32, hwBoardRatedPower Integer32, hwBoardThresholdOfPower Integer32, hwBoardTypicalPower Integer32 } -- 1.2.1.1.1 hwBoardIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the board index." ::= { hwBoardPowerMngtEntry 1 } -- 1.2.1.1.2 hwBoardType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the board type." ::= { hwBoardPowerMngtEntry 2 } -- 1.2.1.1.3 hwBoardName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the board name." ::= { hwBoardPowerMngtEntry 3 } -- 1.2.1.1.4 hwBoardCurrentPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the current power consumption of a board." ::= { hwBoardPowerMngtEntry 4 } -- 1.2.1.1.5 hwBoardRatedPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the rated power consumption of a board." ::= { hwBoardPowerMngtEntry 5 } -- 1.2.1.1.6 hwBoardThresholdOfPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the board power consumption threshold." ::= { hwBoardPowerMngtEntry 6 } -- 1.2.1.1.7 hwBoardTypicalPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the typical power consumption of a board." ::= { hwBoardPowerMngtEntry 7 } -- 1.3 hwEnergySavingMngt OBJECT IDENTIFIER ::= { hwEnergyMngt 3 } -- 1.3.1 hwEnergySavingMode OBJECT-TYPE SYNTAX INTEGER { userDefined(1), standard(2), basic(3), deep(4), optimal(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the NE-level energy saving mode." ::= { hwEnergySavingMngt 1 } -- 1.3.2 hwEnergySavingMethodTable OBJECT-TYPE SYNTAX SEQUENCE OF HwEnergySavingMethodEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used to query the energy saving mode." ::= { hwEnergySavingMngt 2 } -- 1.3.2.1 hwEnergySavingMethodEntry OBJECT-TYPE SYNTAX HwEnergySavingMethodEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of energy-saveing method table." INDEX { hwEnergySavingMethodIndex } ::= { hwEnergySavingMethodTable 1 } HwEnergySavingMethodEntry ::= SEQUENCE { hwEnergySavingMethodIndex Integer32, hwEnergySavingMethodEnable INTEGER } -- 1.3.2.1.1 hwEnergySavingMethodIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the index of the energy saving mode." ::= { hwEnergySavingMethodEntry 1 } -- 1.3.2.1.2 hwEnergySavingMethodEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the status of the energy saving mode." ::= { hwEnergySavingMethodEntry 2 } -- 1.3.3 hwEnergySavingParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF HwEnergySavingParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the variable of the energy saving mode." ::= { hwEnergySavingMngt 3 } -- 1.3.3.1 hwEnergySavingParameterEntry OBJECT-TYPE SYNTAX HwEnergySavingParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of energy-saveing parameter table." INDEX { hwEnergySavingMethodIndex, hwEnergySavingParameterIndex } ::= { hwEnergySavingParameterTable 1 } HwEnergySavingParameterEntry ::= SEQUENCE { hwEnergySavingParameterIndex Integer32, hwEnergySavingParameterValue DisplayString (SIZE (0..64)) } -- 1.3.3.1.1 hwEnergySavingParameterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the index of the energy saving mode." ::= { hwEnergySavingParameterEntry 1 } -- 1.3.3.1.2 hwEnergySavingParameterValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the variable of the energy saving mode." ::= { hwEnergySavingParameterEntry 2 } -- 1.3.4 hwEnergySavingCapabilityMngtTable OBJECT-TYPE SYNTAX SEQUENCE OF HwEnergySavingCapabilityMngtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the energy-saving capability, including energy-saving methods and parameters. The index is hwEnergySavingCapabilityDescIndex. " ::= { hwEnergySavingMngt 4 } -- 1.3.4.1 hwEnergySavingCapabilityMngtEntry OBJECT-TYPE SYNTAX HwEnergySavingCapabilityMngtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry of hwBoardPowerMngtTable." INDEX { hwEnergySavingCapabilityDescIndex } ::= { hwEnergySavingCapabilityMngtTable 1 } HwEnergySavingCapabilityMngtEntry ::= SEQUENCE { hwEnergySavingCapabilityDescIndex Integer32, hwEnergySavingCapabilityDescLanguage DisplayString (SIZE (0..64)), hwEnergySavingCapabilityDesc OCTET STRING } -- 1.3.4.1.1 hwEnergySavingCapabilityDescIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the index of the energy saving capability description." ::= { hwEnergySavingCapabilityMngtEntry 1 } -- 1.3.4.1.2 hwEnergySavingCapabilityDescLanguage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the energy saving capability description language." ::= { hwEnergySavingCapabilityMngtEntry 2 } -- 1.3.4.1.3 hwEnergySavingCapabilityDesc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10240)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the energy saving capability description." ::= { hwEnergySavingCapabilityMngtEntry 3 } -- 1.3.5 hwEnergySavingDescReqMode OBJECT-TYPE SYNTAX INTEGER { snmp(1), ftp(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the method of obtaining the energy saving capability description file." ::= { hwEnergySavingMngt 5 } -- 1.4 hwEnergyFtpcObjects OBJECT IDENTIFIER ::= { hwEnergyMngt 4 } -- == Ftpc Table == hwEnergyFtpcTransFileTable OBJECT-TYPE SYNTAX SEQUENCE OF HwEnergyFtpcTransFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used to configure transfer file feature related parameters." ::= { hwEnergyFtpcObjects 1 } hwEnergyFtpcTransFileEntry OBJECT-TYPE SYNTAX HwEnergyFtpcTransFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Name identifying Transfer configuration" INDEX { hwEnergyFtpcSetName } ::= { hwEnergyFtpcTransFileTable 1 } HwEnergyFtpcTransFileEntry ::= SEQUENCE { hwEnergyFtpcSetName OCTET STRING, hwEnergyFtpcSrcAddrType InetAddressType, hwEnergyFtpcSrcAddr InetAddress, hwEnergyFtpcVpnName OCTET STRING, hwEnergyFtpcHostAddrType InetAddressType, hwEnergyFtpcHostAddr InetAddress, hwEnergyFtpcServerPort Integer32, hwEnergyFtpcUserName OCTET STRING, hwEnergyFtpcPassword OCTET STRING, hwEnergyFtpcDirectory OCTET STRING, hwEnergyFtpcSrcIfName OCTET STRING, hwEnergyFtpcTransCfgRowStatus RowStatus, hwEnergyFtpcAction INTEGER, hwEnergyFtpcTransMode INTEGER, hwEnergyFtpOperStatus INTEGER } hwEnergyFtpcSetName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..31)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Name identifying FTPC Transfer configuration" ::= { hwEnergyFtpcTransFileEntry 1 } hwEnergyFtpcSrcAddrType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "Source IP address Type: ipv4(1) ipv6(2)" ::= { hwEnergyFtpcTransFileEntry 2 } hwEnergyFtpcSrcAddr OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Source IP address" ::= { hwEnergyFtpcTransFileEntry 3 } hwEnergyFtpcVpnName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..31)) MAX-ACCESS read-create STATUS current DESCRIPTION "VPN name used for the corresponding connection" ::= { hwEnergyFtpcTransFileEntry 4 } hwEnergyFtpcHostAddrType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "Server address type: ipv4(1) ipv6(2)" ::= { hwEnergyFtpcTransFileEntry 5 } hwEnergyFtpcHostAddr OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Server IP address" ::= { hwEnergyFtpcTransFileEntry 6 } hwEnergyFtpcServerPort OBJECT-TYPE SYNTAX Integer32 (21 | 1025..55535) MAX-ACCESS read-create STATUS current DESCRIPTION "Server port used for connection" ::= { hwEnergyFtpcTransFileEntry 7 } hwEnergyFtpcUserName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..85)) MAX-ACCESS read-create STATUS current DESCRIPTION "User Name used for user validation" ::= { hwEnergyFtpcTransFileEntry 8 } hwEnergyFtpcPassword OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..25)) MAX-ACCESS read-create STATUS current DESCRIPTION "Password used for user validation. Password Length while setting should not be more than 16 characters, while querying password will be cipher text" ::= { hwEnergyFtpcTransFileEntry 9 } hwEnergyFtpcDirectory OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-create STATUS current DESCRIPTION "Local working directory" ::= { hwEnergyFtpcTransFileEntry 10 } hwEnergyFtpcSrcIfName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..48)) MAX-ACCESS read-create STATUS current DESCRIPTION "Interface Name" ::= { hwEnergyFtpcTransFileEntry 11 } hwEnergyFtpcTransCfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The object specifies the status of this table entry. When the status is createAndGo, it allows to create and when value is destroy it allows to delete the record in the table" ::= { hwEnergyFtpcTransFileEntry 12 } hwEnergyFtpcAction OBJECT-TYPE SYNTAX INTEGER { get(1), put(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of request. get(1): To request a file from the FTP server. put(2): To send a file to the FTP server." ::= { hwEnergyFtpcTransFileEntry 13 } hwEnergyFtpcTransMode OBJECT-TYPE SYNTAX INTEGER { ftp(1), sftp(2), tftp(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The file transfer protocol. Default: FTP." ::= { hwEnergyFtpcTransFileEntry 14 } hwEnergyFtpOperStatus OBJECT-TYPE SYNTAX INTEGER { opInProgress(1), opSuccess(2), opInvalid(3), opInvalidProtocol(4), opInvalidSourceName(5), opInvalidDestName(6), opInvalidServerAddress(7), opDeviceBusy(8), opDeviceError(9), opFileOpenError(10), opFileTransferError(11), opFileChecksumError(12), opAuthFail(13), opUnknownFailure(14), opAbort(15), opInvalidSourceAddress(16), opInvalidSourceInterface(17) } MAX-ACCESS read-only STATUS current DESCRIPTION "The OperStatus: opInProgress(1): the operation is in process. opSuccess(2): the operation has been completed successfully. opInvalid(3): the command is invalid or command-protocol-device combination is unsupported by the system. opInvalidProtocol(4): invalid protocol is specified opInvalidSourceName(5) :invalid source file name is specified. opInvalidDestName(6): invalid target name is specified. opInvalidServerAddress(7): invalid server address is specified opDeviceBusy(8): the device is in use and locked by another process opDeviceError(9): device read, write or erase error opFileOpenError(10) :invalid file name; file not found in partition opFileTransferError(11) :file transfer was unsuccessfull opFileChecksumError(12) :file checksum in Flash is invalid opAuthFail(13) :authentication failure opUnknownFailure(14) :failure which is unknown opAbort(15) : transfer operation has been aborted opInvalidSourceAddress(16): invalid source IP is specified. opInvalidSourceInterface(17): invalid source interface is specified. " ::= { hwEnergyFtpcTransFileEntry 15 } hwEnergyTrapObjects OBJECT IDENTIFIER ::= { hwEnergyMngt 10 } hwEnergyDevId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object identifies the device ID." ::= { hwEnergyTrapObjects 1 } hwEnergyNotification OBJECT IDENTIFIER ::= { hwEnergyMngt 11 } hwEnergyDevChangeToSleep NOTIFICATION-TYPE OBJECTS { hwEnergyDevId } STATUS current DESCRIPTION "This notification indicates device entering in the sleeping status." ::= { hwEnergyNotification 1 } hwEnergyConformance OBJECT IDENTIFIER ::= { hwEnergyMngt 6 } hwEnergyCompliances OBJECT IDENTIFIER ::= { hwEnergyConformance 1 } hwEnergyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Description." MODULE -- this module MANDATORY-GROUPS { hwEnergyFtpcGroup } ::= { hwEnergyCompliances 1 } hwEnergyGroups OBJECT IDENTIFIER ::= { hwEnergyConformance 2 } hwEnergyFtpcGroup OBJECT-GROUP OBJECTS { hwEnergyFtpcSrcAddrType, hwEnergyFtpcSrcAddr, hwEnergyFtpcVpnName, hwEnergyFtpcHostAddrType, hwEnergyFtpcHostAddr, hwEnergyFtpcServerPort, hwEnergyFtpcUserName, hwEnergyFtpcPassword, hwEnergyFtpcDirectory, hwEnergyFtpcSrcIfName, hwEnergyFtpcTransCfgRowStatus } STATUS current DESCRIPTION "Description." ::= { hwEnergyGroups 1 } -- hwSysPowerMgntGroups OBJECT IDENTIFIER ::= { hwEnergyConformance 3 } hwSysPowerMgntGroup OBJECT-GROUP OBJECTS { hwThresholdOfPower,hwPowerConsumption,hwPowerStatPeriod,hwAveragePower,hwRatedPower,hwCurrentPower,hwPSEPower,hwPoEType,hwTypicalPower } STATUS current DESCRIPTION "Description." ::= { hwEnergyGroups 2 } -- hwEnergySavingMngtGroups OBJECT IDENTIFIER ::= { hwEnergyConformance 4 } hwEnergySavingMngtGroup OBJECT-GROUP OBJECTS { hwEnergySavingMode,hwEnergySavingMethodIndex,hwEnergySavingParameterIndex,hwEnergySavingCapabilityDescIndex,hwEnergySavingDescReqMode } STATUS current DESCRIPTION "Description." ::= { hwEnergyGroups 3 } hwEnergyNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { hwEnergyDevChangeToSleep } STATUS current DESCRIPTION "Description." ::= { hwEnergyGroups 4 } -- 1.12 hwChassisPowerMngt OBJECT IDENTIFIER ::= { hwEnergyMngt 12 } -- 1.12.1 hwChassisPowerMngtTable OBJECT-TYPE SYNTAX SEQUENCE OF HwChassisPowerMngtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes chassis-level power consumption attributes." ::= { hwChassisPowerMngt 1 } -- 1.12.1.1 hwChassisPowerMngtEntry OBJECT-TYPE SYNTAX HwChassisPowerMngtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry of hwChassisPowerMngtTable." INDEX { hwChassisId } ::= { hwChassisPowerMngtTable 1 } HwChassisPowerMngtEntry ::= SEQUENCE { hwChassisId Integer32, hwChassisRealPower Integer32 } -- 1.12.1.1.1 hwChassisId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the chassis ID." ::= { hwChassisPowerMngtEntry 1 } -- 1.12.1.1.2 hwChassisRealPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the real power consumption of a chassis. The value is expressed in mW." ::= { hwChassisPowerMngtEntry 2 } END -- -- HUAWEI-ENERGYMNGT-MIB --