-- (C) COPYRIGHT HEWLETT-PACKARD COMPANY 2005. -- -- LaserJet 3800 Printer Model Specific MIB. -- -- Generated on Jul. 26, 2005. -- -- Company names and product names mentioned herein may be -- trademarks, and/or registered trademarks of their respective -- companies. -- -- For internal and external use. -- -- This MIB describes all the printer model specific -- objects supported by the LaserJet 3800 printer -- when networked connected using a JetDirect print -- server. -- -- The following MIBs also contain objects supported -- by a JetDirect connected LaserJet 3800 printer: -- -- rfc 1514 Host Resources MIB -- rfc 1759 Printer MIB -- rfc 1213 MIB II -- -- This MIB complies with the following RFCs: -- -- rfc 1157 Simple Network Management Protocol -- rfc 1155 Structure of Management Information -- -- Notes: -- -- 1) Objects containing a string which are defined in this MIB use the -- first two bytes to hold the symbol set used to encode the string. -- The Roman-8 symbol set has a hex encoding of 0x0115. Other -- symbol sets are listed in the PCL 5 Comparison Guide in table -- C-1 Symbol Set Values. -- -- 2) Some of the objects included are only supported if an accessory -- is installed. These accessories include: -- MIO based accessories -- SIMM based accessories -- AT hard disk -- Paper handling accessories -- Adobe PostScript accessory LJ3800-MIB DEFINITIONS ::= BEGIN hp OBJECT IDENTIFIER ::= { iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 11} netPMLmgmt OBJECT IDENTIFIER ::= { hp nm(2) system(3) netperipheral(9) netPML(4) 2} DisplayString ::= OCTET STRING device OBJECT IDENTIFIER ::= { netPMLmgmt 1 } device-system OBJECT IDENTIFIER ::= { device 1 } status-system OBJECT IDENTIFIER ::= { device-system 2 } test OBJECT IDENTIFIER ::= { device-system 5 } job OBJECT IDENTIFIER ::= { device-system 6 } job-info OBJECT IDENTIFIER ::= { job 5 } job-info-accounting OBJECT IDENTIFIER ::= { job-info 28 } processing-subsystem OBJECT IDENTIFIER ::= { device 3 } pml OBJECT IDENTIFIER ::= { processing-subsystem 4 } settings-system OBJECT IDENTIFIER ::= { device-system 1 } interface OBJECT IDENTIFIER ::= { device-system 4 } simm OBJECT IDENTIFIER ::= { interface 1 } simm1 OBJECT IDENTIFIER ::= { simm 1 } simm1-bank OBJECT IDENTIFIER ::= { simm1 6 } simm1-bank1 OBJECT IDENTIFIER ::= { simm1-bank 1 } simm1-bank2 OBJECT IDENTIFIER ::= { simm1-bank 2 } simm2 OBJECT IDENTIFIER ::= { simm 2 } simm2-bank OBJECT IDENTIFIER ::= { simm2 6 } simm2-bank1 OBJECT IDENTIFIER ::= { simm2-bank 1 } simm2-bank2 OBJECT IDENTIFIER ::= { simm2-bank 2 } simm3 OBJECT IDENTIFIER ::= { simm 3 } simm3-bank OBJECT IDENTIFIER ::= { simm3 6 } simm3-bank1 OBJECT IDENTIFIER ::= { simm3-bank 1 } simm3-bank2 OBJECT IDENTIFIER ::= { simm3-bank 2 } simm4 OBJECT IDENTIFIER ::= { simm 4 } simm4-bank OBJECT IDENTIFIER ::= { simm4 6 } simm4-bank1 OBJECT IDENTIFIER ::= { simm4-bank 1 } simm4-bank2 OBJECT IDENTIFIER ::= { simm4-bank 2 } simm5 OBJECT IDENTIFIER ::= { simm 5 } simm5-bank OBJECT IDENTIFIER ::= { simm5 6 } simm5-bank1 OBJECT IDENTIFIER ::= { simm5-bank 1 } simm5-bank2 OBJECT IDENTIFIER ::= { simm5-bank 2 } settings-job OBJECT IDENTIFIER ::= { job 1 } operating-system OBJECT IDENTIFIER ::= { device-system 19 } pdl OBJECT IDENTIFIER ::= { processing-subsystem 3 } settings-pdl OBJECT IDENTIFIER ::= { pdl 1 } status-pdl OBJECT IDENTIFIER ::= { pdl 2 } background-message OBJECT IDENTIFIER ::= { status-system 37 } background-message1 OBJECT IDENTIFIER ::= { background-message 1 } background-message2 OBJECT IDENTIFIER ::= { background-message 2 } destination-subsystem OBJECT IDENTIFIER ::= { device 4 } print-engine OBJECT IDENTIFIER ::= { destination-subsystem 1 } menus OBJECT IDENTIFIER ::= { print-engine 13 } errorlog OBJECT IDENTIFIER ::= { device-system 11 } error1 OBJECT IDENTIFIER ::= { errorlog 1 } error2 OBJECT IDENTIFIER ::= { errorlog 2 } error3 OBJECT IDENTIFIER ::= { errorlog 3 } error4 OBJECT IDENTIFIER ::= { errorlog 4 } error5 OBJECT IDENTIFIER ::= { errorlog 5 } error6 OBJECT IDENTIFIER ::= { errorlog 6 } error7 OBJECT IDENTIFIER ::= { errorlog 7 } error8 OBJECT IDENTIFIER ::= { errorlog 8 } error9 OBJECT IDENTIFIER ::= { errorlog 9 } error10 OBJECT IDENTIFIER ::= { errorlog 10 } error11 OBJECT IDENTIFIER ::= { errorlog 11 } error12 OBJECT IDENTIFIER ::= { errorlog 12 } error13 OBJECT IDENTIFIER ::= { errorlog 13 } error14 OBJECT IDENTIFIER ::= { errorlog 14 } error15 OBJECT IDENTIFIER ::= { errorlog 15 } error16 OBJECT IDENTIFIER ::= { errorlog 16 } error17 OBJECT IDENTIFIER ::= { errorlog 17 } error18 OBJECT IDENTIFIER ::= { errorlog 18 } error19 OBJECT IDENTIFIER ::= { errorlog 19 } error20 OBJECT IDENTIFIER ::= { errorlog 20 } error21 OBJECT IDENTIFIER ::= { errorlog 21 } error22 OBJECT IDENTIFIER ::= { errorlog 22 } error23 OBJECT IDENTIFIER ::= { errorlog 23 } error24 OBJECT IDENTIFIER ::= { errorlog 24 } error25 OBJECT IDENTIFIER ::= { errorlog 25 } error26 OBJECT IDENTIFIER ::= { errorlog 26 } error27 OBJECT IDENTIFIER ::= { errorlog 27 } error28 OBJECT IDENTIFIER ::= { errorlog 28 } error29 OBJECT IDENTIFIER ::= { errorlog 29 } error30 OBJECT IDENTIFIER ::= { errorlog 30 } error31 OBJECT IDENTIFIER ::= { errorlog 31 } error32 OBJECT IDENTIFIER ::= { errorlog 32 } error33 OBJECT IDENTIFIER ::= { errorlog 33 } error34 OBJECT IDENTIFIER ::= { errorlog 34 } error35 OBJECT IDENTIFIER ::= { errorlog 35 } error36 OBJECT IDENTIFIER ::= { errorlog 36 } error37 OBJECT IDENTIFIER ::= { errorlog 37 } error38 OBJECT IDENTIFIER ::= { errorlog 38 } error39 OBJECT IDENTIFIER ::= { errorlog 39 } error40 OBJECT IDENTIFIER ::= { errorlog 40 } error41 OBJECT IDENTIFIER ::= { errorlog 41 } error42 OBJECT IDENTIFIER ::= { errorlog 42 } error43 OBJECT IDENTIFIER ::= { errorlog 43 } error44 OBJECT IDENTIFIER ::= { errorlog 44 } error45 OBJECT IDENTIFIER ::= { errorlog 45 } error46 OBJECT IDENTIFIER ::= { errorlog 46 } error47 OBJECT IDENTIFIER ::= { errorlog 47 } error48 OBJECT IDENTIFIER ::= { errorlog 48 } error49 OBJECT IDENTIFIER ::= { errorlog 49 } error50 OBJECT IDENTIFIER ::= { errorlog 50 } channel OBJECT IDENTIFIER ::= { device 6 } display OBJECT IDENTIFIER ::= { status-system 20 } display-status OBJECT IDENTIFIER ::= { display 1 } id OBJECT IDENTIFIER ::= { device-system 3 } pdl-pcl OBJECT IDENTIFIER ::= { pdl 3 } pdl-postscript OBJECT IDENTIFIER ::= { pdl 4 } socket-ping OBJECT IDENTIFIER ::= { interface 7 } active-print-jobs OBJECT IDENTIFIER ::= { job 2 } job-being-parsed OBJECT IDENTIFIER ::= { active-print-jobs 1 } job-info-attribute OBJECT IDENTIFIER ::= { job-info 23 } held-job OBJECT IDENTIFIER ::= { job 7 } held-job-info OBJECT IDENTIFIER ::= { held-job 1 } held-job-control OBJECT IDENTIFIER ::= { held-job 2 } source-subsystem OBJECT IDENTIFIER ::= { device 2 } spooler OBJECT IDENTIFIER ::= { source-subsystem 4 } settings-spooler OBJECT IDENTIFIER ::= { spooler 1 } pjl OBJECT IDENTIFIER ::= { processing-subsystem 5 } mio OBJECT IDENTIFIER ::= { interface 3 } mio1 OBJECT IDENTIFIER ::= { mio 1 } mio4 OBJECT IDENTIFIER ::= { mio 4 } usb-interface OBJECT IDENTIFIER ::= { interface 9 } usb OBJECT IDENTIFIER ::= { usb-interface 2 } io OBJECT IDENTIFIER ::= { source-subsystem 1 } settings-io OBJECT IDENTIFIER ::= { io 1 } ports OBJECT IDENTIFIER ::= { io 3 } port1 OBJECT IDENTIFIER ::= { ports 1 } tables OBJECT IDENTIFIER ::= { device 7 } remote-procedure-call OBJECT IDENTIFIER ::= { device-system 13 } settings-rpc OBJECT IDENTIFIER ::= { remote-procedure-call 1 } status-rpc OBJECT IDENTIFIER ::= { remote-procedure-call 2 } file-system OBJECT IDENTIFIER ::= { device-system 10 } settings-file-system OBJECT IDENTIFIER ::= { file-system 1 } file-systems OBJECT IDENTIFIER ::= { file-system 3 } file-system2 OBJECT IDENTIFIER ::= { file-systems 2 } file-system3 OBJECT IDENTIFIER ::= { file-systems 3 } file-system4 OBJECT IDENTIFIER ::= { file-systems 4 } resource-manager OBJECT IDENTIFIER ::= { device-system 12 } mass-storage-resources OBJECT IDENTIFIER ::= { resource-manager 3 } mass-storage-block-driver OBJECT IDENTIFIER ::= { device-system 15 } settings-mass-storage-bd OBJECT IDENTIFIER ::= { mass-storage-block-driver 1 } status-mass-storage-bd OBJECT IDENTIFIER ::= { mass-storage-block-driver 2 } device-configure OBJECT IDENTIFIER ::= { settings-system 32 } settings-prt-eng OBJECT IDENTIFIER ::= { print-engine 1 } marking-agent-density OBJECT IDENTIFIER ::= { settings-prt-eng 9 } status-prt-eng OBJECT IDENTIFIER ::= { print-engine 2 } printer-calibration-dhalf OBJECT IDENTIFIER ::= { status-prt-eng 37 } printer-cal-dhalf-data OBJECT IDENTIFIER ::= { printer-calibration-dhalf 3 } printer-calibration-cpr OBJECT IDENTIFIER ::= { status-prt-eng 38 } intray OBJECT IDENTIFIER ::= { print-engine 3 } settings-intray OBJECT IDENTIFIER ::= { intray 1 } intrays OBJECT IDENTIFIER ::= { intray 3 } intray1 OBJECT IDENTIFIER ::= { intrays 1 } intray2 OBJECT IDENTIFIER ::= { intrays 2 } intray3 OBJECT IDENTIFIER ::= { intrays 3 } outbin OBJECT IDENTIFIER ::= { print-engine 4 } settings-outbin OBJECT IDENTIFIER ::= { outbin 1 } outbins OBJECT IDENTIFIER ::= { outbin 3 } outbin1 OBJECT IDENTIFIER ::= { outbins 1 } marking-agent OBJECT IDENTIFIER ::= { print-engine 5 } settings-marking-agent OBJECT IDENTIFIER ::= { marking-agent 1 } print-media OBJECT IDENTIFIER ::= { print-engine 8 } settings-print-media OBJECT IDENTIFIER ::= { print-media 1 } media-info OBJECT IDENTIFIER ::= { print-media 3 } media1 OBJECT IDENTIFIER ::= { media-info 1 } media2 OBJECT IDENTIFIER ::= { media-info 2 } media3 OBJECT IDENTIFIER ::= { media-info 3 } media4 OBJECT IDENTIFIER ::= { media-info 4 } media5 OBJECT IDENTIFIER ::= { media-info 5 } media6 OBJECT IDENTIFIER ::= { media-info 6 } media7 OBJECT IDENTIFIER ::= { media-info 7 } media8 OBJECT IDENTIFIER ::= { media-info 8 } media9 OBJECT IDENTIFIER ::= { media-info 9 } media10 OBJECT IDENTIFIER ::= { media-info 10 } media11 OBJECT IDENTIFIER ::= { media-info 11 } media12 OBJECT IDENTIFIER ::= { media-info 12 } media13 OBJECT IDENTIFIER ::= { media-info 13 } media14 OBJECT IDENTIFIER ::= { media-info 14 } media15 OBJECT IDENTIFIER ::= { media-info 15 } media16 OBJECT IDENTIFIER ::= { media-info 16 } media17 OBJECT IDENTIFIER ::= { media-info 17 } media18 OBJECT IDENTIFIER ::= { media-info 18 } media19 OBJECT IDENTIFIER ::= { media-info 19 } media20 OBJECT IDENTIFIER ::= { media-info 20 } media21 OBJECT IDENTIFIER ::= { media-info 21 } media22 OBJECT IDENTIFIER ::= { media-info 22 } media23 OBJECT IDENTIFIER ::= { media-info 23 } media24 OBJECT IDENTIFIER ::= { media-info 24 } media25 OBJECT IDENTIFIER ::= { media-info 25 } media26 OBJECT IDENTIFIER ::= { media-info 26 } media-modes OBJECT IDENTIFIER ::= { print-media 4 } media-types OBJECT IDENTIFIER ::= { print-media 8 } media-counts OBJECT IDENTIFIER ::= { print-media 7 } media-size OBJECT IDENTIFIER ::= { print-media 5 } consumables OBJECT IDENTIFIER ::= { print-engine 10 } consumables-1 OBJECT IDENTIFIER ::= { consumables 1 } consumable-status OBJECT IDENTIFIER ::= { consumables-1 1 } consumable-string OBJECT IDENTIFIER ::= { consumables 8 } consumables-status OBJECT IDENTIFIER ::= { consumables 5 } consumables-life OBJECT IDENTIFIER ::= { consumables-status 1 } print-meter OBJECT IDENTIFIER ::= { print-engine 11 } printer-average OBJECT IDENTIFIER ::= { print-meter 1 } webserver-proc-sub OBJECT IDENTIFIER ::= { processing-subsystem 9 } settings-webserver OBJECT IDENTIFIER ::= { webserver-proc-sub 1 } firmware-download OBJECT IDENTIFIER ::= { device-system 18 } upgradable-devices OBJECT IDENTIFIER ::= { device-system 20 } perm-store-init-occurred OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "This object will set the cAllPermDevices bit when a full perm storage initialization occurs (as would be the case for a brand new system or as a result of a powerup key sequence or <> object request). If only one device was initialized (as would be the case if a disk were added to an existing system or a formatter were swapped out), then only the appropriate collection bits will be returned. If there are no collection bits set then this indicates that no initialization took place." ::= { status-system 10 } self-test OBJECT-TYPE SYNTAX INTEGER { eNotInASelfTest(1), eNonDestructiveSelfTest(4) } ACCESS read-write STATUS optional DESCRIPTION "Writing this object allows a device self test to be started. Reading this object provides an indication what self-test is currently executing, if any. Actual self-test operation is device specific. A self test may not be allowed at any arbitrary time. If the device supports the requested self test, but can not start the execution of the self test when requested, the device will respond with . If a non-destructive self test is being started, the device will generate a response before the self test is completed. RECOMMENDATION: If the device is ready (i.e. the NOT-READY-PRINTER object does not contain any items, except maybe being off-line) and is idle (i.e. the NOT-IDLE object does not contain any items), this request should always succeed. This provides a mechanism for driver writers to always determine if the action will succeed or not. Additional information: The eNonDestructiveSelfTest performs limited testing on the printer and its attached paper handling devices. After the self-test is complete a configuration page is printed. The recommended way to cause a configuration page to be printed is to use the PRINT-INTERNAL-PAGE object. Setting this object to eNonDestructiveSelfTest results in a status of and a value of eNonDestructiveSelfTest being returned. If the printer is not idle (whether printing an external job or printing an internal page), this action will be delayed until the next job boundary. See the PRINT-INTERNAL-PAGE object for more details." ::= { test 1 } print-internal-page OBJECT-TYPE SYNTAX INTEGER { eNotPrintingAnInternalPage(1), ePrintingAnUnknownInternalPage(2), eDeviceDemoPage1ConfigurationPage(3), eDeviceDemoPage2(4), eDeviceDemoPage5ErrorLog(7), eDeviceDemoPage6FileSystemDirectoryListing(8), eDeviceDemoPage7MenuMap(9), ePrintUsagePage(100), eSuppliesPage(101), eDeviceAutoCleaningPage(252), eDeviceCleaningPage(253), eDevicePaperPathTest(254), eDevicePageRegistrationPage(255), ePrintQualityPages(256), eColorPaletteRGBPage(258), eColorPaletteCMYKPage(259), eDevicePageDiagnosticsPage(260), ePCLFontList1(350), ePSFontList(450) } ACCESS read-write STATUS optional DESCRIPTION "Writing this object to a value other than eNotPrintingAnInternalPage causes the device to attempt to print an internally generated page. Reading this object provides an indication what internally generated page is currently being printed, if any. The actual page is device specific. Some devices may support continuously printing an internally generated page. Setting this object to eNotPrintingAnInternalPage terminates continuously printing internally generated pages. An internally generated page may not be allowed to be printed at any arbitrary time; under what conditions it will succeed or fail is device specific. If the device supports the requested page, but can not start printing the page when requested, the device will respond with . RECOMMENDATION: If the device is ready (i.e. the NOT-READY-PRINTER object does not contain any items, except maybe being off-line) and is idle (i.e. the NOT-IDLE object does not contain any items), this request should always succeed. This provides a mechanism for driver writers to always determine if the action will succeed or not. Additional information: Previous products used ePCLDemoPage1ConfigurationPage(300) for the Configuration or Self Test page. This product uses eDeviceDemoPage1ConfigurationPage(3). $product_str does not support continuously printing a demo page. When this object is set to a valid value, the status returned is and the value returned is ePrintingAnUnknownInternalPage. If the printer is idle, the page will be printed immediately. If the printer is currently printing another job, the internal page requested will not print until that job is finished. Setting this object to a valid value causes the desired page to be formatted and put in the printer's print queue. While the page is being formatted a get on this object will return the value ePrintingAnUnknownInternalPage. Once the page (or pages) is finished being formatted, this object returns a value of eNotPrintingAnInternalPage, even though the page may not have finished being printed. Setting this object multiple times will queue up the requests, but only a limited number will be queued. Once the queue is full, additional requests will be ignored." ::= { test 2 } job-info-accounting-color-usage-log OBJECT-TYPE SYNTAX INTEGER { eClear(1), ePrint(2) } ACCESS write-only STATUS optional DESCRIPTION "Provides applications with the ability to clear or print the Color Usage Log. eClear - clear the log. ePrint - print the log. Either action will complete before any subsequent action is performed. Additional information: Provides applications with the ability to clear or print the Color Usage Log. eClear - clear the log. ePrint - print the log. Either action will complete before any subsequent action is performed." ::= { job-info-accounting 32 } energy-star OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the Energy Star sleep value. If the value is greater than zero, then the device will go into energy saving sleep mode after the print engine has been idle for the number of seconds specified by this object. A value of zero means Energy Star is disabled and the device will not go to sleep based on print engine idle time. The value must be non-negative. Additional information: Returns or changes the Energy Star sleep value. The device will go into energy saving sleep mode after the print engine has been idle for the number of seconds specified by this object. Laserjet 4700 MFP supports values of 0, 60, 900, 1800, 2700, 3600, 5400, 7200, 14400 seconds. A value of 0 means never enter sleep mode based on the print engine idle time. Setting to an unsupported value causes the printer to substitute a value (listed below) and to return status. Setting this value when the printer is in sleep mode will not cause it to wakeup unless it is set to 0. The values are as follow: <=0 snap to 0 >=1 and <= 1349 snap to 900 (15 minutes) >=1350 and <= 2249 snap to 1800 (30 minutes) >=2250 and <= 3149 snap to 2700 (45 minutes) >=3150 and <= 4499 snap to 3600 (1 hour) >=4500 and <= 6299 snap to 5400 (90 minutes) >=6300 and <= 10799 snap to 7200 (2 hours) >=10800 snap to 14400 (4 hours)." ::= { settings-system 1 } sleep-mode OBJECT-TYPE SYNTAX INTEGER { eFalse(1), eTrue(2) } ACCESS read-write STATUS optional DESCRIPTION "Returns eTrue if the device is in energy saving sleep mode, otherwise returns eFalse. Setting SLEEP-MODE to eFalse causes the device to wake up, if it is in sleep mode. Setting SLEEP-MODE to eTrue causes the device to go into sleep mode. Additional information: This object returns eTrue if the device is in energy saving sleep mode, otherwise it returns eFalse. Setting this object to eTrue while the printer is awake will not change the printer's current state and will return status. NOTE: This object should behave this way when the printer does not have an instant-on fuser. Setting this object to eTrue while printer is already in Sleep Mode will not change the printer's current state and will return status. Setting this object to eFalse while printer is already awake will not change the printer's current state and will return status. Setting this object to eFalse while the printer is asleep causes the device to wake up. " ::= { settings-system 2 } on-off-line OBJECT-TYPE SYNTAX INTEGER { eOnline(1), eOffline(2), eOfflineAtEndOfJob(3) } ACCESS read-write STATUS optional DESCRIPTION "To bring the PDL processing sub-system on or off line. If the device is a printer, then the printer does not process print job data when the printer is off line. PML communication persists. Additional information: When the printer is in the Offline state, printing will stop as soon as possible (no more sheets of media are pulled from input trays). The I/O is taken offline also. Setting to eOnline has the following affect: Printer will immediately go to or remain in the Online state; status is returned. If the printer's current state is Offline with a pending error condition that prevents the printer from going to the Online state, the printer will remain in the Offline state; status is returned Setting to eOffline has the following affect: Printer will immediately go to or remain in the Offline state; status is returned. If pages are being printed, those pages will complete with the printer in the Offline state. Setting to eOfflineAtEndOfJob has the following affect: If not in a job or already in the Offline state, the printer will immediately go to or remain in the Offline state; status is returned. If in a job and the current state is Online, the printer will remain in the Online state, with the value of this object as eOfflineAtEndOfJob, until the end of the job; status is returned. At the end of the job, the printer goes to the Offline state and the value of this object becomes eOffline. Setting this object to eOffline or eOnline before the end of the job causes the action for that value to be taken immediately." ::= { status-system 5 } continue OBJECT-TYPE SYNTAX INTEGER { eInitiateAction(1) } ACCESS write-only STATUS optional DESCRIPTION "A device can support a class of errors called continuable errors. When a continuable error is encountered, the device requires a continue event to occur before the device will continue operation. One continue event is setting the CONTINUE object to eInitiateAction. Devices can support other continue events, like auto-continue. A continue event causes the continuable error to be acknowledged, thus allowing the device to continue. Each device needs to list the continuable errors. If the device doesn't currently have an unacknowledged continuable error, the response will contain . Additional information: See the CLEARABLE-WARNING and AUTO-CONTINUE objects for the errors that this object will clear." ::= { status-system 6 } auto-continue OBJECT-TYPE SYNTAX INTEGER { eOff(1), eOn(2) } ACCESS read-write STATUS optional DESCRIPTION "Indicates if the device will automatically continue after encountering a continuable error. If AUTO-CONTINUE is set to eOn, the device will automatically generate continue event to acknowledge continuable errors. If AUTO-CONTINUE is set to eOff, then some other continue event will have to acknowledge the continuable error. Additional information: If this is set to eOn the device displays an error message and goes offline for ten seconds. After ten seconds the printer automatically returns to the online state. If this is set to eOff then the device displays an error message and goes offline. It remains offline until the operator presses the GO key or until the CONTINUE object is set. If the printer is not idle, the new value may not take effect until a job boundary is reached. If a get is done on this object before the job boundary is reached, the value last set will be returned." ::= { status-system 7 } simm1-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in SIMM slot 1. eEmpty means the device did not detect any option installed in the interface slot. eUnknown means the device doesn't recognize the installed option. eUnSupported means the device recognizes the installed option, but does not support the option. eReadOnlyMemory means the installed option contains ROM Ics. eVolatileRandomAccessMemory means the installed option contains RAM ICs that loose data when the power is turned off. eNonVolatileRandomAccessMemory means that the installed option contains RAM ICs that do not loose data when the power is turned off. eFlashMemory means that the installed option contains a type of non-volatile RAM that needs to be erased before it can be written. eDiskDrive means the installed option contains a disk drive. eRamRom means the installed option contains both volatile random access memory and read only memory. eInputPHD means the installed option is an input paper handling device. eOutputPHD means the installed option is an output paper handling device. eIOCard means the installed option is an I/O card. Additional information: This object is used for describing DIMMs instead of SIMMs on $product_str. eRamRom is used to denote $product_str's combo simm." ::= { simm1 4 } simm1-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of the SIMM installed in SIMM slot 1. The capacity is dependent on the type of option, as indicated by the SIMM1-TYPE object. This object has no meaning if the installed option type is eUnknown or eReadOnlyMemory. This object contains the size, in bytes, if the installed option type is eVolatileRandomAccessMemory, eNonVolatileRandomAccessMemory, eFlashMemory, or eDiskDrive. If the type of the installed option is eRamRom, this object contains the size, in bytes, of the random access memory. If the type of the installed option is eInputPHD, the capacity indicates the number of input trays supported by the installed option. If the type of the installed option is eOutputPHD, the capacity indicates the number of output bins supported by the installed option. If the type of the installed option is eIOCard, the capacity indicates the number of logical I/O ports supported by the I/O card. Additional information: Returns an indication of the capacity of the installed option in bytes. This object is not supported unless the SIMM1-TYPE type is eVolatileRandomAccessMemory, eRamRom, or eFlashMemory. For eRamRom only the size of the Ram portion of the SIMM is returned." ::= { simm1 5 } simm1-bank1-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in Bank 1 of SIMM slot 1. See SIMM1-TYPE for a description. Additional information: This object is used for describing the type of DIMM banks. Each physical DIMM slot has up to 2 banks." ::= { simm1-bank1 1 } simm1-bank1-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of Bank 1 of the SIMM installed in SIMM slot 1. See SIMM1-CAPACITY for a description. Additional information: Returns an indication of the capacity of the installed bank option in bytes. This object is not supported unless the SIMM1-BANK1-TYPE type is eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory, eSDRandomAccessMemory, eSRandomAccessMemory, or eFPMRandomAccessMemory." ::= { simm1-bank1 2 } simm1-bank2-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in Bank 2 of SIMM slot 1. See SIMM1-TYPE for a description. Additional information: This object is used for describing the type of DIMM banks. Each physical DIMM slot has up to 2 banks." ::= { simm1-bank2 1 } simm1-bank2-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of Bank 2 of the SIMM installed in SIMM slot 1. See SIMM1-CAPACITY for a description. Additional information: Returns an indication of the capacity of the installed bank option in bytes. This object is not supported unless the SIMM1-BANK2-TYPE type is eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory, eSDRandomAccessMemory, eSRandomAccessMemory, or eFPMRandomAccessMemory." ::= { simm1-bank2 2 } simm2-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in SIMM slot 2. See SIMM1-TYPE for a description. Additional information: This object is used for describing DIMMs instead of SIMMs on $product_str. eRamRom is used to denote $product_str's combo simm." ::= { simm2 4 } simm2-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of the SIMM installed in SIMM slot 2. See SIMM1-CAPACITY for a description. Additional information: This object is used for describing DIMMs instead of SIMMs on $product_str. Returns an indication of the capacity of the installed option in bytes. This object is not supported unless the SIMM2-TYPE type is eVolatileRandomAccessMemory, eRamRom, or eFlashMemory. For eRamRom only the size of the Ram portion of the SIMM is returned." ::= { simm2 5 } simm2-bank1-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in Bank 1 of SIMM slot 2. See SIMM1-TYPE for a description. Additional information: This object is used for describing the type of DIMM banks. Each physical DIMM slot has up to 2 banks." ::= { simm2-bank1 1 } simm2-bank1-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of Bank 1 of the SIMM installed in SIMM slot 2. See SIMM1-CAPACITY for a description. Additional information: Returns an indication of the capacity of the installed bank option in bytes. This object is not supported unless the SIMM2-BANK1-TYPE type is eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory, eSDRandomAccessMemory, eSRandomAccessMemory, or eFPMRandomAccessMemory." ::= { simm2-bank1 2 } simm2-bank2-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in Bank 2 of SIMM slot 2. See SIMM1-TYPE for a description. Additional information: This object is used for describing the type of DIMM banks. Each physical DIMM slot has up to 2 banks." ::= { simm2-bank2 1 } simm2-bank2-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of Bank 2 of the SIMM installed in SIMM slot 2. See SIMM1-CAPACITY for a description. Additional information: Returns an indication of the capacity of the installed bank option in bytes. This object is not supported unless the SIMM2-BANK2-TYPE type is eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory, eSDRandomAccessMemory, eSRandomAccessMemory, or eFPMRandomAccessMemory." ::= { simm2-bank2 2 } simm3-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in SIMM slot 3. See SIMM1-TYPE for a description." ::= { simm3 4 } simm3-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of the SIMM installed in SIMM slot 3. See SIMM1-CAPACITY for a description. Additional information: This object is used for describing DIMMs instead of SIMMs on $product_str. Returns an indication of the capacity of the installed option in bytes. This object is not supported unless the SIMM3-TYPE type is eVolatileRandomAccessMemory, eRamRom, or eFlashMemory. For eRamRom only the size of the Ram portion of the simm is returned." ::= { simm3 5 } simm3-bank1-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in Bank 1 of SIMM slot 3. See SIMM1-TYPE for a description. Additional information: This object is used for describing the type of DIMM banks. Each physical DIMM slot has up to 2 banks." ::= { simm3-bank1 1 } simm3-bank1-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of Bank 1 of the SIMM installed in SIMM slot 3. See SIMM1-CAPACITY for a description. Additional information: Returns an indication of the capacity of the installed bank option in bytes. This object is not supported unless the SIMM3-BANK1-TYPE type is eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory, eSDRandomAccessMemory, eSRandomAccessMemory, or eFPMRandomAccessMemory." ::= { simm3-bank1 2 } simm3-bank2-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in Bank 2 of SIMM slot 3. See SIMM1-TYPE for a description. Additional information: This object is used for describing the type of DIMM banks. Each physical DIMM slot has up to 2 banks." ::= { simm3-bank2 1 } simm3-bank2-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of Bank 2 of the SIMM installed in SIMM slot 3. See SIMM1-CAPACITY for a description. Additional information: Returns an indication of the capacity of the installed bank option in bytes. This object is not supported unless the SIMM3-BANK2-TYPE type is eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory, eSDRandomAccessMemory, eSRandomAccessMemory, or eFPMRandomAccessMemory." ::= { simm3-bank2 2 } simm4-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in SIMM slot 4. See SIMM1-TYPE for a description." ::= { simm4 4 } simm4-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of the SIMM installed in SIMM slot 4. See SIMM1-CAPACITY for a description. Additional information: This object is used for describing DIMMs instead of SIMMs on $product_str. Returns an indication of the capacity of the installed option in bytes. This object is not supported unless the SIMM4-TYPE type is eVolatileRandomAccessMemory, eRamRom, or eFlashMemory. For eRamRom only the size of the Ram portion of the simm is returned." ::= { simm4 5 } simm4-bank1-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in Bank 1 of SIMM slot 4. See SIMM1-TYPE for a description. Additional information: This object is used for describing the type of DIMM banks. Each physical DIMM slot has up to 2 banks." ::= { simm4-bank1 1 } simm4-bank1-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of Bank 1 of the SIMM installed in SIMM slot 4. See SIMM1-CAPACITY for a description. Additional information: Returns an indication of the capacity of the installed bank option in bytes. This object is not supported unless the SIMM4-BANK1-TYPE type is eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory, eSDRandomAccessMemory, eSRandomAccessMemory, or eFPMRandomAccessMemory." ::= { simm4-bank1 2 } simm4-bank2-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in Bank 2 of SIMM slot 4. See SIMM1-TYPE for a description. Additional information: This object is used for describing the type of DIMM banks. Each physical DIMM slot has up to 2 banks." ::= { simm4-bank2 1 } simm4-bank2-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of Bank 2 of the SIMM installed in SIMM slot 4. See SIMM1-CAPACITY for a description. Additional information: Returns an indication of the capacity of the installed bank option in bytes. This object is not supported unless the SIMM4-BANK2-TYPE type is eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory, eSDRandomAccessMemory, eSRandomAccessMemory, or eFPMRandomAccessMemory." ::= { simm4-bank2 2 } simm5-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in SIMM slot 5. See SIMM1-TYPE for a description." ::= { simm5 4 } simm5-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of the SIMM installed in SIMM slot 5. See SIMM1-CAPACITY for a description. Additional information: This object is used for describing DIMMs instead of SIMMs on $product_str. Returns an indication of the capacity of the installed option in bytes. This object is not supported unless the SIMM5-TYPE type is eVolatileRandomAccessMemory, eRamRom, or eFlashMemory. For eRamRom only the size of the Ram portion of the simm is returned." ::= { simm5 5 } simm5-bank1-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in Bank 1 of SIMM slot 5. See SIMM1-TYPE for a description. Additional information: This object is used for describing the type of DIMM banks. Each physical DIMM slot has up to 2 banks." ::= { simm5-bank1 1 } simm5-bank1-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of Bank 1 of the SIMM installed in SIMM slot 5. See SIMM1-CAPACITY for a description. Additional information: Returns an indication of the capacity of the installed bank option in bytes. This object is not supported unless the SIMM5-BANK1-TYPE type is eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory, eSDRandomAccessMemory, eSRandomAccessMemory, or eFPMRandomAccessMemory." ::= { simm5-bank1 2 } simm5-bank2-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eUnSupported(3), eReadOnlyMemory(4), eVolatileRandomAccessMemory(5), eFlashMemory(7), eRamRom(9), eVolatileRAMOnBoardMemory(10) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in Bank 2 of SIMM slot 5. See SIMM1-TYPE for a description. Additional information: This object is used for describing the type of DIMM banks. Each physical DIMM slot has up to 2 banks." ::= { simm5-bank2 1 } simm5-bank2-capacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the capacity of Bank 2 of the SIMM installed in SIMM slot 5. See SIMM1-CAPACITY for a description. Additional information: Returns an indication of the capacity of the installed bank option in bytes. This object is not supported unless the SIMM5-BANK2-TYPE type is eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory, eSDRandomAccessMemory, eSRandomAccessMemory, or eFPMRandomAccessMemory." ::= { simm5-bank2 2 } cancel-job OBJECT-TYPE SYNTAX INTEGER(-1..32767) ACCESS write-only STATUS optional DESCRIPTION "Cancels the print job whose ID matches the value written to the CANCEL-JOB object. The host first learns the job ID using the CURRENT-JOB-PARSING-ID command. If the printer has completely processed the job, the printer responds with . If the value of the CURRENT-JOB-PARSING-ID is smaller than the value written to the CANCEL-JOB object, then the printer responds with . When read, returns the value of the last job ID what was canceled, or -1 to indicate no job has been canceled. Additional information: If the value written matches the ID of a job that is currently being canceled (for any reason), the printer responds with . It uses job ID's in the range of -1..32767. Because the ID number can wrap to zero, CURRENT-JOB-PARSING-ID may be smaller than the value written to this object; when this occurs, no error will result as long as the ID is for a currently processing job. This object is write only, so the comment in the general description stating the job ID will be returned on a read does not apply. A -1 represents the current job" ::= { settings-job 2 } os-execute-file OBJECT-TYPE SYNTAX OCTET STRING ACCESS write-only STATUS optional DESCRIPTION "This object's input is a null-terminated string representing a fully-qualified path name for an executable file. This object causes the file to be executed by the OS. Additional information: This object's input is a null-terminated string of two or more whitespace-separated tokens. The first token is a path to a directory to make the current working directory. The second token is a path to an executable file to be executed. Any remaining whitespace-separated tokens are optional and will be passed as parameters to the executable. The paths to the directory and executable can be either PJL style (e.g., 1:\app\example) or UNIX-style (e.g., /hpmnt/dsk_ide1a/app/example). The executable is run in a separate process." ::= { operating-system 1 } form-feed OBJECT-TYPE SYNTAX INTEGER { eInitiateAction(1) } ACCESS write-only STATUS optional DESCRIPTION "Instructs the PDL processing sub-system to finishing processing the current page of the current job. Form feed is also known as close page or eject page. If the PDL processing sub-system is in a FORM-FEED-NEEDED state, this causes the device to flush or finish processing the current page of the current job. If the device is not in the FORM-FEED-NEEDED state, an will occur." ::= { settings-pdl 5 } form-feed-needed OBJECT-TYPE SYNTAX INTEGER { eFalse(1), eTrue(2) } ACCESS read-only STATUS optional DESCRIPTION "Indicates if the PDL processing sub-system has made marks on the current page and the source subsystem has been idle for a device specific amount of time. Additional information: $product_str will set this object to eTrue when it has made marks on the current page, the IO-TIMEOUT has expired while PCL was running in `backward-compatibility mode' (which is caused by jobs consisting purely of PCL data with no prepended PJL commands), and no data is pending on another I/O. Once it is set to eTrue, more data on the same I/O will cause this object to be set to eFalse, until the above conditions are met again." ::= { status-pdl 2 } background-status-msg-line1-part1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-write STATUS optional DESCRIPTION "The string displayed on the device's front panel in place of the printer's built-in background status string. An example built-in background status string is '00 READY'. Additional information: The display size for the $product_str printers is 2 X 16. The value of this object and the current value of BACKGROUND-STATUS-MSG-LINE2-PART1 are displayed together on the 2-line display, but they must be set independently. If line 2 has been set, and the next message to be displayed only requires line 1, BACKGROUND-STATUS-MSG-LINE2-PART1 must be set to the null string to clear it. This object allows a message to be displayed when it is the highest priority message. Setting this object does not guarantee the message will be displayed; and reading it returns the value last written, not the currently displayed message (use prtConsoleDisplayBufferText to read the display). The priority assigned for displaying this message is one lower than the READY message. In other words, the only message that can be replaced by these objects is the READY message. To clear the message, write a null string to both this object and BACKGROUND-STATUS-MSG-LINE2-PART1." ::= { background-message1 1 } background-status-msg-line2-part1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-write STATUS optional DESCRIPTION "The string displayed on the device's front panel in place of the printer's built-in background status string. An example built-in background status string is '00 READY'. Additional information: See BACKGROUND-STATUS-MSG-LINE1-PART1" ::= { background-message2 1 } error-log-clear OBJECT-TYPE SYNTAX INTEGER { eClearErrorLog(1) } ACCESS write-only STATUS optional DESCRIPTION "Setting this object clears all the entries in the error log sub-tree. Additional information: Setting this object removes all errors that have been stored in the printer's non-volatile memory." ::= { status-system 38 } clearable-warning OBJECT-TYPE SYNTAX INTEGER { eOn(2), eJob(3) } ACCESS read-write STATUS optional DESCRIPTION "Returns or controls how the device will track clearable warnings. A clearable warning indicates a transient event in the device. The device will continue after the transient event occurs. If CLEARABLE-WARNING is eOff, the device does not track clearable warnings. If CLEARABLE-WARNING is eOn, all clearable warnings will be tracked until cleared (acknowledged). If CLEARABLE-WARNING is eJob, a clearable warning generated due to an event that occurs because of the print job being processed will be automatically cleared when the device has finished processing the job. Example clearable warning events include the device altering resolution or page protection due to memory constraints. The POS will document what transient events are treated as clearable warnings. Additional information: If set to eOn, the warning is displayed until the GO key is pressed or the CONTINUE object is set. If set to eJob, the warning is displayed until the end of the job in which it was generated." ::= { settings-job 1 } error1-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 1 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: This item contains the engine page count when the error occurred. If there is currently no error entry for this object, a '0' will be returned. Note that '0' may also be returned when there is a valid error, but a current page count was unavailable. If ERROR1-CODE object also returns '0', then an error has not yet been logged for this object. See ERROR1-CODE for an explanation of the order used for storing errors." ::= { error1 1 } error1-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: Returns a device specific error code. If the error code returned is '0', then the printer has not yet logged an error for this object. When the maximum number of errors is reached (30 on LaserJet printers), and a new error occurs, the error in ERROR1-CODE will be replaced by the one in ERROR2-CODE, and so on until the last error object will be given the value of the new error. The error number is returned in the upper 16 bits. If it is 68, 69, 79, or 80, then the sub code is returned in the lower 16 bits (eg. 68 001C, where the subcode is already a hexadecimal value). If the error number is any other number, then the 1st sub code (XX) will be in bits 15-8 and the 2nd sub code (YY) will be in bits 7-0 (eg. 55.04.02) where XX=04 and YY=02). Example: If the error is 68 001A, then the value returned will be 4456474. To break it down: 4456474 = 0x0044001A The upper 16 bits: 0x0044 = 68 The lower 16 bits: 0x001A = 001A Which is the error: 68 001A Example: If the error is 55.04.241, then the error code will be 3605745. To break it down: 3605745 = 0x003704F1 The upper 16 bits: 0x0037 = 55 The upper byte of the lower 16 bits: 0x04 = 04 The lower byte of the lower 16 bits: 0xF1 = 241 Which is the error: 55.04.241" ::= { error1 2 } error2-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 2 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error2 1 } error2-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error2 2 } error3-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 3 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error3 1 } error3-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error3 2 } error4-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 4 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error4 1 } error4-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error4 2 } error5-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 5 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error5 1 } error5-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error5 2 } error6-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 6 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error6 1 } error6-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error6 2 } error7-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 7 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error7 1 } error7-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error7 2 } error8-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 8 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error8 1 } error8-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error8 2 } error9-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 9 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error9 1 } error9-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error9 2 } error10-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 10 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error10 1 } error10-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error10 2 } error11-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 11 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error11 1 } error11-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error11 2 } error12-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 12 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error12 1 } error12-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error12 2 } error13-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 13 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error13 1 } error13-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error13 2 } error14-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 14 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error14 1 } error14-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error14 2 } error15-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 15 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error15 1 } error15-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error15 2 } error16-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 16 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error16 1 } error16-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error16 2 } error17-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 17 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error17 1 } error17-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error17 2 } error18-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 18 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error18 1 } error18-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error18 2 } error19-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 19 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error19 1 } error19-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error19 2 } error20-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 20 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error20 1 } error20-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error20 2 } error21-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 21 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error21 1 } error21-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error21 2 } error22-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 22 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error22 1 } error22-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error22 2 } error23-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 23 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error23 1 } error23-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error23 2 } error24-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 24 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error24 1 } error24-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error24 2 } error25-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 25 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error25 1 } error25-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error25 2 } error26-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 26 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error26 1 } error26-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error26 2 } error27-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 27 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error27 1 } error27-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error27 2 } error28-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 28 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error28 1 } error28-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error28 2 } error29-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 29 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error29 1 } error29-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error29 2 } error30-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 30 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error30 1 } error30-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error30 2 } error31-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 31 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error31 1 } error31-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error31 2 } error32-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 32 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error32 1 } error32-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error32 2 } error33-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 33 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error33 1 } error33-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error33 2 } error34-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 34 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error34 1 } error34-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error34 2 } error35-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 35 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error35 1 } error35-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error35 2 } error36-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 36 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error36 1 } error36-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error36 2 } error37-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 37 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error37 1 } error37-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error37 2 } error38-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 38 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error38 1 } error38-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error38 2 } error39-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 39 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error39 1 } error39-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error39 2 } error40-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 40 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error40 1 } error40-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error40 2 } error41-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 41 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error41 1 } error41-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error41 2 } error42-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 42 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error42 1 } error42-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error42 2 } error43-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 43 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error43 1 } error43-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error43 2 } error44-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 44 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error44 1 } error44-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error44 2 } error45-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 45 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error45 1 } error45-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error45 2 } error46-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 46 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error46 1 } error46-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error46 2 } error47-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 47 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error47 1 } error47-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error47 2 } error48-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 48 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error48 1 } error48-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error48 2 } error49-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 49 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error49 1 } error49-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error49 2 } error50-time-stamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains some sort of time stamp indicating when error 50 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the total engine page count. The device POS documents the meaning of the time stamp. Additional information: See ERROR1-TIME-STAMP." ::= { error50 1 } error50-code OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. Additional information: See ERROR1-CODE." ::= { error50 2 } channelprinteralert OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Identifies the values of prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup, prtAlertGroupIndex, prtAlertLocation, and prtAlertCode for the latest critical evnet in the prtAlertTable. The binary string is defined as following: ----------------------------------------------------- Field | Filed | Description Offset | Length | ----------------------------------------------------- 0 | 4 | the value of prtAlertIndex 4 | 4 | the value of prtAlertSeverityLevel 8 | 4 | the value of prtAlertGroup 12 | 4 | the value of prtAlertGroupIndex 16 | 4 | the value of prtAlertLocation 20 | 4 | the value of prtAlertCode ------------------------------------------------------
Each field is in Big Endian style. Additional information: This object is used to pass alert information from the peripheral to the IIO card. The standard printer MIB contains the following description: printerAlert TRAP-TYPE ENTERPRISE printerV1Alert VARIABLES { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup, prtAlertGroupIndex, prtAlertLocation, prtAlertCode } DESCRIPTION 'This trap is sent whenever a critical event is added to the prtAlertTable.' In order to provide this information in the trap packet, the IIO card enables traps on channelPrinterAlert. When a critical alert is generated the peripheral fills the appropriate value into this object and sends it to the card. This object is a structure which contains 24 bytes of data. The structure is: struct structAlertInfo { sint32 prtAlertIndex; sint32 prtAlertSeverityLevel; sint32 prtAlertGroup; sint32 prtAlertGroupIndex; sint32 prtAlertLocation; sint32 prtAlertCode; } thisAlertData;" ::= { channel 2 } install-date OBJECT-TYPE SYNTAX OCTET STRING (SIZE(13)) ACCESS read-write STATUS optional DESCRIPTION "Identifies the date that the device was installed. The format of the string is 'YYYYMMDDHHmmZ'. Where: YYYY is the year. MM is the month (1-12). DD is the day (1-31). HH is the hour of the day (0-23). mm are the minutes (0-59). 'Z' designates Greenwich Mean Time; if 'Z' not specified, value is local time. Device POS must specify the conditions for setting this object. Additional information: Setting the <> object will enable setting this object." ::= { status-system 8 } timestamp OBJECT-TYPE SYNTAX OCTET STRING (SIZE(15)) ACCESS write-only STATUS optional DESCRIPTION "Sets the printer's current time in (UTC). The format of the string is 'YYYYMMDDHHMMSS'. Where YYYY is the year. MM is the month (1-12) DD is the day of the month (1-31) HH is the hour of the day (0-23) MM is the minutes (0-59) SS is the seconds (0-59) Device POS must specify the conditions for setting this object." ::= { status-system 13 } service-id OBJECT-TYPE SYNTAX OCTET STRING (SIZE(5)) ACCESS read-write STATUS optional DESCRIPTION "A read of this object will return the current SERVICE ID value in the printer. The format is 'YYDDD' where: YY = calendar year - 1990 DDD = (calendar month - 1) * 30 + (calendar day of the month or 30, if > 30) A write of this object will only succeed if the MANUFACTURING-CONTROL PML object has been set with the correct <>. If the write operation is not allowed, this object will return an status. Additional information: Setting the <> object will enable setting this object." ::= { status-system 19 } show-address OBJECT-TYPE SYNTAX INTEGER { eOff(1), eAuto(3) } ACCESS read-write STATUS optional DESCRIPTION "If this object is set to eAuto, and the device has an IP address, the IP address of the device will be shown with the READY message. If this object is set to eOff, the IP address will not be shown." ::= { display-status 3 } serial-number OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..10)) ACCESS read-only STATUS optional DESCRIPTION "Identifies the serial number for the device. If the SERIAL-NUMBER object is set by the user, then setting the object does not need to be protected. If the SERIAL-NUMBER object is set at the factory, then the <> object must be set correctly before the SERIAL-NUMBER object is writable. If this is a writable object, the POS should indicate the maximum supported string length. If possible, encode the serial number in a symbol set (like Roman-8) that matches the ASCII character set and limit the characters used to ASCII characters. Additional information: This value IS AFFECTED BY NVRAM resets, it is set to the default value of XXXXXXXXXX, when a NVRAM init is done." ::= { id 3 } fw-rom-datecode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Identifies the base system firmware date code. The date code will be encoded in the yyyymmdd format. There may be several versions of the base system firmware. The date code associated with the version of the base system firmware that is being used is reported. There may be other date code objects for other specific modules such as fonts, localization modules, etc.; these other datecode objects are device specific." ::= { id 5 } fw-rom-revision OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "This identifies the system code firmware ROM revision code. The format for a revision is major_revision.minor_revision. There may be other ROM revision code objects for other specific ROMs such as font ROMs, localization ROMs, etc; these other ROM revision code objects are device specific." ::= { id 6 } device-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) ACCESS read-write STATUS optional DESCRIPTION "User defined device name. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as much as possible and will return the .Additional information: The maximum supported string length is 32 characters. If the user entered string is too long, the device will store the first 32 characters and will return the status." ::= { id 10 } device-location OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "User defined device location. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as much as possible and will return the .Additional information: The maximum supported string length is 16 characters. If the user entered string is too long, the device will store the first 16 characters and will return the status." ::= { id 11 } asset-number OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "User defined asset number. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as much as possible and will return the .Additional information: The maximum supported string length is 8 characters. If the user entered string is too long, the device will store the first 8 characters and will return the status." ::= { id 12 } default-copies OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or changes default copies. Default copies is the default values used by the PDL to control the number of copies of each page in the print job that are printed. The print job can override this value. The list of supported values should be documented in the device POS. Additional information: The supported values are 1 through 32000. Setting to an unsupported value causes the printer to substitute in a snap value and to return status. The snaps are as follows: <1 snaps to 1 >999 snaps to 32000" ::= { settings-pdl 4 } default-lines-per-page OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the default number of lines per page. The POS indicates the supported values. An unsupported value causes the printer to use the closest supported value, causing the printer to return the . Additional information: The supported values in $product_str are 5 to 128. Setting to an unsupported value causes the the printer to substitute in a snap value and to return status. The snap values are as follow: <5 snaps to 5 >128 snaps to 128" ::= { settings-pdl 11 } default-vmi OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the default vertical motion index. The unit of measure for VMI is centipoints per line. The POS indicates the supported values. An unsupported value causes the printer to use the closest supported value, causing the printer to return ." ::= { settings-pdl 12 } default-media-size OBJECT-TYPE SYNTAX INTEGER { eUSExecutive(1), eUSLetter(2), eUSLegal(3), eLedger(11), eROC16K(17), eJISExecutive(18), eROC8K(19), eISOandJISA5(25), eISOandJISA4(26), eISOandJISA3(27), eJISB5(45), eJISB4(46), eISOB5(65), eJapanesePostcardDouble(72), eMonarch(80), eCommercial10(81), eInternationalDL(90), eInternationalC5(91), eInternationalB5(100), eCustom(101), eUSLetterR(258), eISOandJISA4R(282), eUnknownMediaSize(32767) } ACCESS read-write STATUS optional DESCRIPTION "This indicates the default media size. A write of an unsupported value causes an . Complete list of supported media sizes along with their dimensions are listed in the ''Media Size Table'' near the end of this document. (for a full list of media size enums see the end of this file) " ::= { settings-pdl 13 } cold-reset-media-size OBJECT-TYPE SYNTAX INTEGER { eUSLetter(2), eISOandJISA4(26) } ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the media size that is used as the DEFAULT-MEDIA-SIZE when a cold reset occurs." ::= { settings-pdl 19 } reprint OBJECT-TYPE SYNTAX INTEGER { eOff(1), eOn(2), eAuto(3) } ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the reprint (jam recovery) setting. If eOn, then the device will reprint pages jammed pages. If eOff, the device will not attempt to reprint jammed pages. If eAuto, a device dependent algorithm (which should be documented in the POS) will be used to determine if the page gets reprinted. This object controls all PDLs, unless a specific PDL supports its own reprint control mechanism. To date, only PostScript has a PDL reprint control mechanism." ::= { settings-pdl 36 } pcl-total-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Total number of PCL pages printed by the device. Additional information: In $product_str the PCL page count is kept in NVRAM, and the NVRAM value is updated at least every 10 pages. NOTE: The value returned by this object will be incremented every page but if power is lost between NVRAM updates, up to 9 pages of the page count may be lost. The page count counter will be reset to zero after 16,777,215 (2^24-1) pages. The page count is incremented when a sheet of media is pulled from an input tray. A duplex printed sheet will cause this counter to be incremented by two." ::= { pdl-pcl 5 } pcl-default-font-height OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the default PCL height. Height is an approximate measure of the body of the type in centipoints. A centipoint is 1/7200 inch. Height applies only to proportional fonts. Point size, in points, can be converted to font height, in centipoints, by multiplying the point size by 100. The POS indicates the supported values. An unsupported value causes the printer to use the closest supported value, causing the printer to return . ''Closest'' means the smallest absolute difference. Additional information: Supported values range from 400 to 99975, in increments of 25 units. Setting to an unsupported value causes the printer to substitute in a snap value and to return status. The snap values are as follow: <=400 snaps to 400 >=99975 snaps to 99975 Unsupported values in the range 400 to 99975 snap DOWN to the previous supported value (i.e 25293 snaps to 25275 or 75038 snaps to 75025)." ::= { pdl-pcl 13 } pcl-default-font-source OBJECT-TYPE SYNTAX INTEGER { eInternal(1), ePermanentSoft(2), eRomSimm2(11), eRomSimm3(12), eRomSimm4(13), eRomSimm5(14) } ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the value of the default font source variable in NVRAM." ::= { pdl-pcl 14 } pcl-default-font-number OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the value of the default font number variable in NVRAM. Writing an unsupported value causes the printer to generate an . Additional information: Valid numbers or 0 - 255, but only font numbers that are included in the PCL FONT LIST are selectable." ::= { pdl-pcl 15 } pcl-default-font-width OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the default PCL font width. Width is expressed as the width of a character in centipoints. A centipoint is 1/7200 inch. Width applies only to fixed space fonts. Pitch, in character per inch, can be converted to font width, in centipoints, by dividing 7200 by the pitch. The POS indicates the supported values. An unsupported value causes the printer to use the closest supported value, causing the printer to return . ''Closest'' means the smallest absolute difference. Additional information: Setting to an unsupported value causes the printer to substitue in a snap value (listed below) and return status. The snap values for pitch are as follow: <=44 snaps to 44 >=9999 snaps to 9999" ::= { pdl-pcl 16 } postscript-total-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Total number of PostScript pages printed by the device. Additional information: This object is only supported if the PostScript option is installed. In $product_str the count is kept in NVRAM, and the NVRAM value is updated at least every 10 sheets. NOTE: The value returned by this object will be incremented every sheet but if power is lost between NVRAM updates up to 9 sheets of the count may be lost. The counter will be reset to zero after 16,777,215 (2^24-1) pages. " ::= { pdl-postscript 5 } postscript-print-errors OBJECT-TYPE SYNTAX INTEGER { eOff(1), eOn(2) } ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the value of the print PostScript errors setting. If eOn, PostScript prints an error page showing the error encountered and the stack at the time of the error. Additional information: This object is only supported if the PostScript option is installed." ::= { pdl-postscript 11 } collated-originals-support OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Indicates that the printer can create multiple, collated 'originals' of a job and shows the level of support for this capability. cCollatedOriginals - The printer can create multiple collated originals, or 'mopies'. This is the base functionality required by the other collection items. cProofAndHold - The printer saves a copy of the job while printing the first mopy. Later, this held job can be released and the rest of the mopies will print. cSecurityPrint - The printer spools the job and holds the job until the user releases the job by entering a <> at the printer's control panel. cAutoHighlight - The printer prints the job a number of times with a mail distribution list prepended to each job. A different mailing address is highlighted on each mopy. cCollatedAtSpeed - The printer can create multiple collated copies where all copies after the original are printed at engine speed. Additional information: Indicates that the printer can create multiple, collated originals of a job and shows the level of support for this capability. cCollatedOriginals - The printer can create multiple collated originals, or mopies. This is the base functionality required by the other collection items. Without disk, this object will not exist. This will be set at boot-up initialization. If the disk fails, in any way, then the disk error functionality will handle the situation. A color printer (LaserJet 4550) that only has a RAMDISK installed is treated like there is no disk and therefore this object will not exist. The value of this object will be: !cCollatedOriginals - Only FLASH installed cCollatedOriginals - IDE is installed combined with/without FLASH cCollatedOriginals - RAMDISK is On combined with/without FLASH" ::= { status-system 42 } host-application-available-memory OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns the amount of memory, in bytes, that the device has available for job-related processing or resources. Also known as driver work space (DWS) memory." ::= { status-system 59 } socket-ping-job-events-version OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..10)) ACCESS read-only STATUS optional DESCRIPTION "This object reports the current version of the Socket Ping Job Events capability. The version number is returned as a string in the format MAJOR.MINOR.SUB version. (eg. 1.0.1) If socket ping is not supported by this printer then the object is either not implemented or it returns a '0'." ::= { socket-ping 1 } job-info-change-id OBJECT-TYPE SYNTAX OCTET STRING (SIZE(16)) ACCESS read-only STATUS optional DESCRIPTION "Returns the current value of an object in the job-info sub-tree whose value has changed. Define the object identifier for the object whose value has changed as job-info.required-field.optional-field.job-id. job-info represents the OID prefix of all objects in the job-info sub-tree. Required-field represents the OID field value that follows the job-info prefix. Since some objects in the job-info sub-tree have two OID fields between the job-info prefix and the job-id, the optional-field represents the OID field between the required-field and the job-id field, if present. Using this definition, the format for the JOB-INFO-CHANGE-ID binary value can be described as follows: Bytes 0-3 : required-field Bytes 4-7 : optional-field, or all zeros if there is no optional field Bytes 8-11: Job ID. Bytes 12-n : The value of the object job-info. required-field.optional-field.job-id. All multi-byte values stored in Motorola (big-endian) format, where the most significant byte occurs first. Additional information: $product_str will use this object to report changes to the job-info-pages-printed and job-info-state objects. The required-field (bytes 0 through 3) will designate whether the change to be reported involves the pages printed (13) or job state (15). The optional-field (bytes 4 through 7) will always be zeroes. The value-field (bytes 12 through 15) will contain the new value for pages printed or job state cast to a 32-bit integer. Note: It is possible that traps generated by this object have the same value. This is caused by the architecture of $product_str. In the $product_str System, it is highly probable that the object value will change so rapidly that when the trap is processed, PML will read the same value twice. This is timing related and will generally be seen at the end of a job." ::= { settings-job 3 } hold-job-timeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The time, in minutes, that the printer will wait before automatically deleting a held job. This allows the printer to automatically clean up jobs that have been forgotten (held but never released). Additional information: This only applies to temporary held jobs, i.e., HOLD=ON or PROOF. This is a global timer that only affects the jobs that are sent after it is set. A value of 0 means never delete the jobs. Setting it to an unsupported value causes the printer to substitute a value (listed below) and to return status. LaserJet 4600 supports values of 0, 60, 240, 1440, and 10080 The values are as follows: <=0 snap to 0 (disabled) >=1 and <=150 snap to 60 (60 minutes) >=151 and <=840 snap to 240 (4 hours) >=841 and <=2880 snap to 1440 (1 day) >=2881 snap to 10080 (1 week)" ::= { settings-job 10 } current-job-parsing-id OBJECT-TYPE SYNTAX INTEGER(-1..2147483647) ACCESS read-only STATUS optional DESCRIPTION "Contains the printer assigned job identification for the job currently being processed by the processing PDL sub-system. The job ID is a monotonically increasing number. The job ID may be reset to zero at power-up and may roll over to zero after reaching some maximum value. Additional information: A value of -1 is returned when the printer is not parsing a job. When data for a new job is detected, this object is updated (the job may or may not turn out to be a Null Job); however, the trap does not occur until the printer determines that it is not a Null Job. (A job is considered to be a 'null job' if it has no name or job attribute, causes no pages to be printed, and consumes MIN_JOB_SIZE (9) or fewer bytes.) A trapped value will differ from the previous value by one or more. Some job-info- objects are created when the first data bytes are received. If the printer determines that the job is a Null Job, the job-info- objects related to the Null Job are deleted. $product_str retains the job-info- objects for the MAX_JOBS_IN_LIST (32) most recent jobs that are not Null Jobs. The first job received after power-up will have job ID 1, and the job ID will increment to 2,147,483,647 before rolling to zero. To distinguish whether a power cycle or a rollover causes a reduction in the job ID value, the object prtGeneralConfigChanges can be watched and if it increments at the same time as the drop is observed in the value of CURRENT-JOB-PARSING-ID, then a power cycle is the most likely cause." ::= { job-being-parsed 1 } job-info-name1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Contains the first part of this print job's name. The last OID field for this dynamic object contains the job ID. Additional information: The job name is the string specified by the NAME= parameter of the @PJL JOB command which allows a maximum of 80 characters. The first 40 characters are in this object and the second 40 are in job-info-name2. The symbol set is Roman-8. When jobs are nested, the value assigned to this object is the name provided by the most recent @PJL JOB NAME= command. If no name is provided, a null string is returned." ::= { job-info 1 } job-info-name2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Contains the second part of this print job's name. The last OID field for this dynamic object contains the job ID. Additional information: See job-info-name1." ::= { job-info 2 } job-info-stage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Indicates what printer sub-systems are currently processing this print job. The last OID field for this dynamic object contains the job ID. cSourceSubsystem - some of the job is in the printer I/O subsystem. cProcessingSubsystem - some of the job is in the printer imaging processing subsystem. cDestinationSubsystem - some of the job is being printed. Additional information: For $product_str, cSourceSubsystem and cProcessingSubsystem will always be set and cleared together. They are set when the beginning of the job is detected, and they are cleared when the end of the job is parsed. A non-printing job will never set cDestinationSubsystem. When a page is ready to be printed (the intermediate has been built and the page is `closed' by the personality), cDestinationSubsystem will be set even if a page of a previous job is currently being printed. cDestinationSubsystem remains set until the last page of the job has finished printing. If a page requires extensive processing and allows all the previous pages of a job to complete printing, cDestinationSubsystem will remain set until the last page of the job has finished printing." ::= { job-info 10 } job-info-io-source OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Indicates which I/O source, the print job was received over. The value maps to port numbering scheme supported in the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree." ::= { job-info 11 } job-info-pages-processed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Indicates the number of pages processed by the processing subsystem. If neither the cSourceSubsystem or the cProcessingSubsystem items are in the associated JOB-INFO-STAGE object, then this object contains the total number of pages processed for this job. The last OID field for this dynamic object contains the job ID. Additional information: This object is incremented by one when a page is processed (`closed' by the personality), regardless of the number of pages that are printed as a result of the single page processed. In other words, it does not matter how many identical copies of a page are printed or no pages may be printed if operating in silent run mode, this count is incremented exactly once. A page is considered processed when all of the input data has been processed for a page (that is, when the intermediate has been produced, and the personality has `closed' the page. At this time, the image of the page is not necessarily completely formed.)" ::= { job-info 12 } job-info-pages-printed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Indicates the number of pages printed by the destination subsystem. If none of the cSourceSubsystem, cProcessingSubsystem or cDestinationSubsystem items are in the associated JOB-INFO-STAGE object, then this object contains the total number of pages printed for this job. This value may increase by two each time for duplex jobs. The last OID field for this dynamic object contains the job ID. Additional information: If multiple copies of a page are printed, each copy is counted individually." ::= { job-info 13 } job-info-size OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Indicates the number of bytes of data processed by the processing subsystem. If neither of the cSourceSubsystem or cProcessingSubsystem items are in the associated JOB-INFO-STAGE object, then this object contains the size of this job, in bytes. The last OID field for this dynamic object contains the job ID. Additional information: This count may be incremented by values other than one as blocks of data are processed; blocks of data (which may be as large as 2K bytes) will be processed in a varying amount of time. During the processing of a job and even when a job completes, an exact count of the number of I/O bytes processed by the job is not necessarily to be expected." ::= { job-info 14 } job-info-state OBJECT-TYPE SYNTAX INTEGER { eAborted(3), eWaitingForResources(4), ePrinted(5), eTerminating(7), eCancelled(10), eProcessing(11), eScanning(12), eSending(13) } ACCESS read-only STATUS optional DESCRIPTION "Indicates the state of the job. The last OID field for this dynamic object contains the job ID. eAborted - the print job was aborted. eWaitingForResources - the print job requires resources that are not currently available. Example resources that can cause the job to wait include the print engine or PDL processor being unavailable. The print engine could be unavailable due to paper out, paper jam, staple out, stapler jam, marking agent low, output bin full, etc. The PDL processor could be unavailable due to an off-line condition. Each printer specific object specification should state which conditions cause a job to be waiting for resources and also state which objects can be retrieved by an application to determine the exact cause of a resource being unavailable. ePrinted - the job has printed. The related JOB-INFO- OUTCOME object indicates if any problems were encountered while the job was processed. eRetained - the job can be reprinted. eTerminating - the job was aborted or cancelled and is currently is terminating. eInterrupted - the job has been interrupted. The job can be continued. ePaused - the job has been paused. The job can be continuted. eCancelled - the job has been cancelled. eProcessing - the job is currently being printed normally. " ::= { job-info 15 } job-info-outcome OBJECT-TYPE SYNTAX INTEGER { eOk(3) } ACCESS read-only STATUS optional DESCRIPTION "Indicates if any warning or error conditions were encountered while processing the assoicated job. The last OID field for this dynamic object contains the job ID. Additional information: In $product_str, warnings and errors are not recorded in this object. Although no meaningful information can be obtained from this object, it is kept around for the compatibility needs of existing software." ::= { job-info 19 } job-info-outbins-used OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Indicates which output bins this job has delivered printed pages to. The last OID field for this dynamic object contains the job ID. Additional information: The bins designated by this collection include the printer's own output bins as well as the `logical output bins' associated with any attached external paper handling devices. (The mapping of the physical output bins of an external paper handling device to its `logical output bins' depends on the usage mode of the device. For instance, in `mailbox mode', there is one-to-one correspondence of `logical output bins' to physical bins, whereas in `stacker mode', one `logical output bin' may map to several physical bins.) Although LaserJet 4100 and LaserJet 4550 both come with two output bins -- a face-down bin on the top of the device and a face-up bin at the back of the device -- firmware will not provide a means of selecting between the two, nor will it report which of the two gets used. For this reason, bit 0 (cOutbin1) of this collection is being used to designate both of these bins together." ::= { job-info 20 } job-info-physical-outbins-used OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Indicates which physical output bins this job has delivered printed pages to. The last OID field for this dynamic object contains the job ID. Additional information: The output bins designated by the bits of this collection include the standard output bin(s) plus the physical bins of attached external paper handling devices. The configuration (if any) of external paper handling devices will determine the mapping of individual bits in this collection to the physical bins of the devices. For LaserJet 4100 and LaserJet 4550, the cOutbin1 is used for Face Down bin, cOutbin2 is used for Face Up bin, and 3-15 are used for the 13 optional output bins (12 plus an extension to the Face Up bin) for backwards compatibility with LaserJet 8000/LaserJet 8100 and forwards compatibility with LaserJet 8150. However, since they cannot distinguish output going to the Face Up or Face Down bin in the firmware because the diverter can only be moved manually, bit 0 (cOutbin1) is being used to designate both of these bits together. If an external paper handling output device is connected, then bit 2 (cOutbin3) will represent the device's first output bin (and so on)." ::= { job-info 22 } job-info-attr-1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. Attribute objects are saved sequentially, starting with 1, after the start of a job. If more attributes are set than there are objects to store them, the excess JOBATTR values are ignored. If the corresponding SET JOBATTR= command has not been received when a get is done for this object, a status of will be returned." ::= { job-info-attribute 1 } job-info-attr-2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 2 } job-info-attr-3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 3 } job-info-attr-4 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 4 } job-info-attr-5 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 5 } job-info-attr-6 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 6 } job-info-attr-7 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 7 } job-info-attr-8 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 8 } job-info-attr-9 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 9 } job-info-attr-10 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 10 } job-info-attr-11 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 11 } job-info-attr-12 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 12 } job-info-attr-13 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 13 } job-info-attr-14 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 14 } job-info-attr-15 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 15 } job-info-attr-16 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..80)) ACCESS read-only STATUS optional DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details." ::= { job-info-attribute 16 } job-info-requested-originals OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The number of requested collated copies. The value was supplied with the job via PJL QTY variable, the PostScript Collate and NumCopies entries in the page device dictionary, or via some other mechansim." ::= { job-info 24 } job-info-page-count-current-original OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The page number being printed within the current copy of a collated multi-copy job. This value changes when the job-info-pages-printed changes. The job-info-pages-printed indicates the total number of pages printed in the job, while this object indicates the number of pages printed for this copy of a collated multi-copy job. Additional information: The number of pages in the current copy of a collated multi-copy job which have been completely printed and safely delivered to the output bin." ::= { job-info 25 } job-info-pages-in-original OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of pages in a single copy of a collated multi-copy job." ::= { job-info 26 } job-info-printed-originals OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of collated copies completely printed and delivered to the output bin at time of query." ::= { job-info 27 } job-info-accounting-media-size OBJECT-TYPE SYNTAX INTEGER { eUSExecutive(1), eUSLetter(2), eUSLegal(3), eLedger(11), eROC16K(17), eJISExecutive(18), eROC8K(19), eISOandJISA5(25), eISOandJISA4(26), eISOandJISA3(27), eJISB5(45), eJISB4(46), eISOB5(65), eJapansePostcardDouble(72), eMonarch(80), eCommercial10(81), eInternationalDL(90), eInternationalC5(91), eInternationalB5(100), eCustom(101), eUSLetterR(258), eISOandJISA4R(282), eUnknownMediaSize(32767) } ACCESS read-only STATUS optional DESCRIPTION "Contains the media size of the printed job. The media size of the first page will decide the media size of the entire job. The return value of this object will only be valid when the printer finishes printing the entire job." ::= { job-info-accounting 1 } job-info-accounting-media-type OBJECT-TYPE SYNTAX INTEGER { eUnknownMedia(1), eStandardType(2), ePreprinted(3), eLetterhead(4), eTransparency(5), eLabels(7), ePrepunched(6), eBond(8), eRecycled(9), eColored(10), eCardStock(11), eRough(12), eHeavy(14), eUserType1(16), eUserType2(17), eUserType3(18), eUserType4(19), eUserType5(20), eExtraHeavy(40), eIntermediate(42), eExtraHeavyGloss(44) } ACCESS read-only STATUS optional DESCRIPTION "Contains the media type of the printed job. The media type of the first page will decide the media type of the entire job. The return value of this object will only be valid when the printer finishes printing the entire job." ::= { job-info-accounting 2 } job-info-accounting-finishing-options OBJECT-TYPE SYNTAX INTEGER { eNoFinish(1), eOffset(2), ePunch(3), eStapler(4), eFinisher(5) } ACCESS read-only STATUS optional DESCRIPTION "Contains the finishing option used on the printed job. The finishing option specified for the first page will decide the finishing option of the entire job. The return value of this object will only be valid when the printer finishes printing the entire job." ::= { job-info-accounting 3 } job-info-accounting-media-simplex-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains the total number of simplex pages printed in a particular job." ::= { job-info-accounting 4 } job-info-accounting-media-duplex-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains the total number of duplex pages printed in a particular job." ::= { job-info-accounting 5 } job-info-accounting-grayscale-impression-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains the total number of monochrome pages printed in a particular job." ::= { job-info-accounting 6 } job-info-accounting-color-impression-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains the total number of color pages printed in a particular job." ::= { job-info-accounting 7 } job-info-accounting-black-dots OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains the total number of black pixels used in a particular job. Additional information: This object reports kilodots. (A kilodot is 1000 dots.)" ::= { job-info-accounting 8 } job-info-accounting-yellow-dots OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains the total number of yellow pixels used in a particular job. Additional information: This object reports kilodots. (A kilodot is 1000 dots.)" ::= { job-info-accounting 9 } job-info-accounting-cyan-dots OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains the total number of cyan pixels used in a particular job. Additional information: This object reports kilodots. (A kilodot is 1000 dots.)" ::= { job-info-accounting 10 } job-info-accounting-magenta-dots OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Contains the total number of magenta pixels used in a particular job. Additional information: This object reports kilodots. (A kilodot is 1000 dots.)" ::= { job-info-accounting 11 } job-info-accounting-job-type OBJECT-TYPE SYNTAX INTEGER { ePrintJob(1), eIPPJob(2), eCopyJob(3), eCopyInterruptJob(4), eJetSendJob(5), eInternalPage(6), eCleaningPage(7), eAutoCleaningPage(8), eDigitalSendJob(9), eWebPrintJob(10), eFaxPrintJob(11), eRetrievedJob(12), ePhotoCardPrintJob(13), eUnknownJob(1000) } ACCESS read-only STATUS optional DESCRIPTION "Keeps track of what type of job is processed. " ::= { job-info-accounting 14 } held-job-user-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..40)) ACCESS read-only STATUS optional DESCRIPTION "User name that is obtained by the driver through some internal method or from user input. Additional information: The following is a general description for all the JOB-MANAGEMENT objects described below. These object describe the attributes of the dynamic list containing all the stored jobs on the disk available for printing or deleting via the job-management feature. The jobs on this list are not deleted from the disk unless explicitly specified by the user. A print job may be specified for retention by PJL commands in the data stream. Following is a list of the PJL commands (i.e. these comments describe the PJL implementation and in some cases do not reflect the PML implementation.): @PJL SET HOLD=OFF|ON|PROOF|STORE|PRINT GENERAL DESCRIPTION: This variable specifies the retention classification of the job. The values indicate whether the job is printed immediately and/or stored. OFF: The job is printed but not retained on disk after printing. This is the default value. ON: This setting may be thought of as free proof-and-hold. The requested number of copies will be printed and the job will be temporarily stored on disk. The job will then be available for printing additional copies through the control panel and through PML. There will be a limit to the number of these temporary jobs that may be stored, and when the limit is exceeded the oldest job will be removed from the disk. PROOF: One copy of the job is printed and remaining copies are stored on disk. The job is then available to select for printing via the control panel menus or PML. The job will be deleted from the disk when the disk space is needed for another proof and hold job but only after the additional copies have been printed. It will also be deleted when the user sends down another proof and hold job with the same job name, or the user explicitly deletes the job. STORE: The job is not printed immediately but is retained on disk. The job is available to select for printing via the control panel DEFAULT VALUE: OFF The value will be stored in RAM only, not in NVRAM. The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed. The variable will appear in the PJL INFO VARIABLES list. @PJL SET USERNAME=<80 bytes> GENERAL DESCRIPTION: Eighty-character user name that is obtained by the driver through some internal method or from user input. If the job stream does not contain a USERNAME the default value will be NO USER NAME. The driver is responsible for determining the size of the printers control panel and sending a string of appropriate length. DEFAULT VALUE: NO USER NAME The value will be stored in RAM only, not in NVRAM. The legal PJL commands are SET and, INQUIRE. DEFAULT is not allowed. The variable will appear in the PJL INFO VARIABLES list. @PJL SET JOBNAME=<80 bytes> GENERAL DESCRIPTION: Eighty-character job name that may be generated by the driver or obtained from user input. This value may be used in conjunction with the USERNAME to select a job from the front panel. If the job stream does not contain a JOBNAME, the printer will assume no job name; each subsequent job that is sent down by the same user would replace the users last job on disk. The driver is responsible for determining the size of the printers control panel and sending a string of appropriate length. NOTE: The limit of 80 bytes is a PJL limit. The limit for PML will be 40 bytes. DEFAULT VALUE: NULL STRING The value will be stored in RAM only, not in NVRAM. The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed. The variable will appear in the PJL INFO VARIABLES list. @PJL SET HOLDTYPE=PUBLIC|PRIVATE GENERAL DESCRIPTION: This variable specifies the privacy level of the job. PUBLIC: The job does not require a PIN in order to be released for printing. This is the default value. PRIVATE: The job requires a PIN in order to be released for printing. The PIN is specified by the HOLDKEY variable. If the HOLDTYPE is set to PRIVATE, a HOLDKEY value must be specified. If no HOLDKEY is specified, the job will be considered PUBLIC. DEFAULT VALUE: PUBLIC The value will be stored in RAM only, not in NVRAM. The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed. The variable will appear in the PJL INFO VARIABLES list. @PJL SET HOLDKEY=4 digits, 0000...9999 GENERAL DESCRIPTION: A 4-digit string, each digit 0-9, that is specified in the job stream and then required to be entered in order to release the job for printing. If a HOLDTYPE is PRIVATE, a HOLDKEY value must be specified. If no HOLDKEY value is specified, a job will be considered PUBLIC. DEFAULT VALUE: NULL STRING The value will be stored in RAM only, not in NVRAM. The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed. The variable will appear in the PJL INFO VARIABLES list. The format for the OID is as follows: 3.4.1.6.x.y <-----> | | | | \ / | job-id in the system / \ PML_JOB_MGNT_ROOT_OID \ job attribute 1..6 x values are 1..6: 1) user-name: user name that is obtained by the driver through some internal method or from user input. 2) job-name: job name may be generated by the driver or obtained from user input. 3) hold: indicates the retention classification of the job. The values indicate whether the job is printed immediately and/or stored. There are 4 options: OFF: The job is printed but not retained on the disk. ON: The job is printed and stored temporarily on the disk. STORE: The job is not printed but stored on the disk. PROOF: One copy of the job is printed and the remaining copies are stored on the disk. 4) holdtype: The variable specifies the security level of the job. PUBLIC: The job does not require a PIN in order to release the job for printing. PRIVATE: The job requires a PIN in order to be released for printing. 5) quantity: number of copies to print. Valid values are 0..999. 6) pin: A 4 digit string, each digit is 0-9, that is specified in the job stream and then required to be entered in order to release the job for printing. y : an unsigned 32-bit number which uniquely identifies the job. The job id for the job remains the same for the job until it is deleted from the held jobs list. For example, the OID below is asking for the user name of the job whose id is 3. The application would issue: OID get 3.4.1.6.1.3 For example, the OID values sequence is as follows: OID returned OID getnext 3.4.1.6 3.4.1.6.1.1 getnext 3.4.1.6.1.1 3.4.1.6.1.2 getnext 3.4.1.6.2.1 3.4.1.6.2.2 *** getnext 3.4.1.6.1.6 3.4.1.6.1.7 getnext 3.4.1.6.2.1 3.4.1.6.2.2 getnext 3.4.1.6.5.2828 3.4.1.6.6.1 NOTE: for example above, job id 2828 is the last job in the list of held jobs. *** Also supported is on the job attributes: OID returned OID getnext 3.4.1.6.1 3.4.1.6.1.1 getnext 3.4.1.6.6 3.4.1.6.6.1" ::= { held-job-info 1 } held-job-job-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..40)) ACCESS read-only STATUS optional DESCRIPTION "The job name may be generated by the driver or obtained from user input." ::= { held-job-info 2 } held-job-retention OBJECT-TYPE SYNTAX INTEGER { eHoldOff(1), eHoldOn(2), eHoldStore(3), eHoldProof(4) } ACCESS read-only STATUS optional DESCRIPTION "Indicates the retention classification of the job. The values indicate whether the job is printed immediately or stored. There are 4 options: eHoldOff: The job is printed but not retained on the disk. eHoldOn: The job is printed and stored temporarily on the disk. eHoldStore: The job is not printed but stored on the disk. eHoldProof: One copy of the job is printed and the remaining copies are stored on the disk. " ::= { held-job-info 3 } held-job-security OBJECT-TYPE SYNTAX INTEGER { eHoldTypePublic(1), eHoldTypePrivate(2) } ACCESS read-only STATUS optional DESCRIPTION "The variable specifies the security level of the job. eHoldTypePublic: The job does not require a PIN in order to release the job for printing. eHoldTypePrivate: The job requires a PIN in order to be released for printing. " ::= { held-job-info 4 } held-job-quantity OBJECT-TYPE SYNTAX INTEGER(1..999) ACCESS read-only STATUS optional DESCRIPTION "Number of copies to print." ::= { held-job-info 5 } held-job-pin OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..4)) ACCESS read-only STATUS optional DESCRIPTION "A string that is specified in the job stream and then required to be entered in order to release the job for printing. PIN stands for Personal Identification Number. Additional information: Must be a 4 digit string, each digit must be 0..9 or a null string if there is no pin. For security purposes, you can no longer get the value of the PIN." ::= { held-job-info 6 } held-job-print OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS write-only STATUS optional DESCRIPTION "Instructs the printer to schedule the specified held job for printing with the specified number of copies. The job-id is used to identify which job to print. A held job can also be printed from the control panel. Additional information: Bytes 0-3 is the job id of the job to print. Bytes 4-7 is the number of copies to print. Bytes 8-11 (optional) contain the PIN for a Private job. " ::= { held-job-control 1 } held-job-delete OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS optional DESCRIPTION "Instructs the printer to delete the specified held job from the list. The job-id is used to identify which job to delete. A held job can also be deleted from the control panel. Additional information: Setting this to a value that is not a Held Job on the system or is a Private Held Job returns . To delete a private Held Job, you must use the PML object HELD-JOB-PRINT with a quantity of 0 and supply the correct HELD-JOB-PIN with the request. (See HELD-JOB-PRINT)" ::= { held-job-control 2 } held-job-set-queue-size OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS optional DESCRIPTION "Sets the maximum number of jobs which can be stored in the held job list. Additional information: Sets the size of the temporary job lists queue." ::= { held-job-control 3 } held-job-enable OBJECT-TYPE SYNTAX INTEGER { eDisabled(1), eEnabled(2) } ACCESS read-write STATUS optional DESCRIPTION "Enables or disables Job Retention (Job Hold). The valid values are eDisabled and eEnabled. (Specifying an invalid mode causes an error to be returned.) When eDisabled is specified all Job Retention (Hold, Proof, Store, PIN Printing) is disabled. When eEnabled is specified, the Job Retention characteristics of a given job are defined by the PJL variable SET HOLD. Additional information: When disabled, held jobs are not removed, but must be explicitly removed through the Control Panel or the PML object HELD-JOB-DELETE." ::= { held-job-control 4 } mopy-mode OBJECT-TYPE SYNTAX INTEGER { eOff(1), eStandard(4), eEnhanced(5) } ACCESS read-write STATUS optional DESCRIPTION "Controls or reports how mopies are generated. eOff turns off the mopy feature. eAuto allows the device to determine the best method for generating mopies based on the device configuration. eStandard spools the I/O data and replays the I/O data multiple times to generate the mopies. eEnhanced spools the rasterized page images and replays the rasterized data to generate the mopies. Typically, the rasterized data will be larger and will allow all but the first mopy to print at speed. If the job being mopied is not extremely complex, then the first mopy will print at speed also." ::= { settings-spooler 1 } direct-connect-ports-enable OBJECT-TYPE SYNTAX INTEGER { eFalse(1), eTrue(2), eUnSupported(3) } ACCESS read-write STATUS optional DESCRIPTION "This object specifies whether all direct connect ports (parallel and USB) are available or ignored. JetDirect, embedded network connectivity, and third party add-on cards (such as Firewire) will be unaffected by setting this object." ::= { settings-system 43 } mio1-model-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Returns product information identifying the I/O card. Example: XXXX." ::= { mio1 2 } mio1-manufacturing-info OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Returns information describing the manufacture of the I/O card installed in MIO/EIO slot 1. May include serial number and firmware revision. Additional information: The format of the string returned is determined by the manufacturer of the EIO device. There is no standard for content of the string." ::= { mio1 3 } mio1-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eUnknown(2), eDiskDrive(8), eIOCard(12) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in MIO/EIO slot 1. See SIMM1-TYPE for an explanation of the enumerations." ::= { mio1 4 } mio1-ip-address OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "This object will return the IP Address of the I/O cards present in the available slots of a printer. Laserjet 4700 MFP supports 2 slots and a Embedded Jet Direct Card. Slot 4 corresponds to the Embedded Jet Direct Card. If there is no I/O card in a particular slot, then a NULL value will be returned." ::= { mio1 6 } mio4-model-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Returns product information identifying the I/O card. Example: XXXX. Additional information: Returns a string describing the firmware version of the embedded JDI LAN card." ::= { mio4 2 } mio4-manufacturing-info OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Returns information describing the manufacture of the I/O card installed in MIO/EIO interface 4. May include serial number and firmware revision. Additional information: Returns a string describing the embedded JDI LAN card." ::= { mio4 3 } mio4-type OBJECT-TYPE SYNTAX INTEGER { eEmpty(1), eIOCard(12) } ACCESS read-only STATUS optional DESCRIPTION "Returns an indication of the type of option installed in MIO/EIO interface 4. See SIMM1-TYPE for an explanation of the enumerations. Additional information: Returns eEmpty if the embedded JDI LAN card is disabled. Returns eIOCard if the embedded JDI LAN card is enabled." ::= { mio4 4 } mio4-ip-address OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "This object will return the IP Address of the I/O cards present in the available slots of a printer. Laserjet 4700 MFP supports 2 slots and a Embedded Jet Direct Card. Slot 4 corresponds to the Embedded Jet Direct Card. If there is no I/O card in a particular slot, then a NULL value will be returned." ::= { mio4 6 } usb-host-supported OBJECT-TYPE SYNTAX INTEGER { eFalse(1), eTrue(2) } ACCESS read-only STATUS optional DESCRIPTION "The USB Host protocol is supported by the device when the value returned is eTrue. The USB Host protocol is not supported when the value returned is eFalse." ::= { usb-interface 1 } usb-serial-number OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Returns the serial number of a connected USB device as defined in the Standard Device Descriptor of the Universal Serial Bus Specification Version 2.0." ::= { usb 1 } usb-manufacturer-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Returns the description of the manufacturer of a connected USB device as defined in the Standard Device Descriptor of the Universal Serial Bus Specification Version 2.0." ::= { usb 2 } usb-product-description OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Returns the product description of a connected USB device as defined in the Standard Device Descriptor of the Universal Serial Bus Specification Version 2.0." ::= { usb 3 } usb-vendor-id OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns the Vendor ID of a connected USB device as defined in the Standard Device Descriptor of the Universal Serial Bus Specification Version 2.0. The value will be in the range 0..65535." ::= { usb 4 } usb-product-id OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns the Product ID of a connected USB device as defined in the Standard Device Descriptor of the Universal Serial Bus Specification Version 2.0. The value will be in the range 0..65535." ::= { usb 5 } usb-device-kind OBJECT-TYPE SYNTAX INTEGER { eUSBStorageDevice(1), eUSBNonStorageDevice(2), eUSBCompositeDevice(3), eUSBUnsupportedDevice(4) } ACCESS read-only STATUS optional DESCRIPTION "The USB-DEVICE-KIND object classifies a USB device into one of four broad categories: \ eUSBStorageDevice(1): The USB device is strictly a device for storing data. \ eUSBNonStorageDevice(2): The USB device has no storage capability (e.g., a card reader). \ eUSBCompositeDevice(3): The USB device has storage capability and additional functionality normally not associated with a storage device. \ eUSBUnsupportedDevice(4): The USB device was detected, but no driver exists for the device or the device draws more current than allowed. \" ::= { usb 6 } usb-driver-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Returns the name of the low-level USB driver supporting this device." ::= { usb 7 } io-timeout OBJECT-TYPE SYNTAX INTEGER(5..300) ACCESS read-write STATUS optional DESCRIPTION "The amount of time, in seconds, to wait for more print job data to be received before an I/O timeout occurs. The I/O channel being timed is the I/O channel that received the data associated with the current print job. If an I/O timeout occurs, the PDL processing sub-system assumes all the data associated with the current print job has been received, and processes the end of job in a PDL specific manner. The POS specifies the supported values. Additional information: If an I/O timeout occurs,the PDL processing sub-system will consider it an end of job condition only if there is data from another I/O subsystem waiting to be processed. The supported values are 5 to 300 seconds. Setting to a value outside the supported range returns status and the value will be snapped to the nearest supported value." ::= { settings-io 1 } io-switch OBJECT-TYPE SYNTAX INTEGER { eYes(1) } ACCESS read-only STATUS optional DESCRIPTION "Indicates if the device will switch between I/O channels when a job boundary is encountered and print job data is available on another I/O channel." ::= { settings-io 2 } port1-parallel-speed OBJECT-TYPE SYNTAX INTEGER { eSlow(1), eFast(2) } ACCESS read-write STATUS optional DESCRIPTION "Returns or changes the maximum parallel I/O port speed, for port 1. This object is only supported if this port is a parallel port. An eSlow setting causes a 10 us busy pulse per received byte of data. An eFast setting causes a 1.5 us busy pulse per received byte of data. In rare cases, setting this value to eFast can cause the parallel port to no longer transfer data reliably. Additional information: When the value of this object is changed, it takes effect immediately. It is recommended that the printer be offline and not in a job when this object is changed." ::= { port1 4 } port1-parallel-bidirectionality OBJECT-TYPE SYNTAX INTEGER { eUnidirectional(1), eBidirectional(2) } ACCESS read-write STATUS optional DESCRIPTION "Returns or changes whether the parallel I/O port supports bidirectional communication for port 1. This object is only supported if this port is a parallel port. Additional information: A get on this object returns the current mode for the parallel port. Setting this object specifies whether or not bidirectional communications will be allowed." ::= { port1 5 } channelnumberofchannels OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS optional DESCRIPTION "An indication of how many print data channels the I/O card supports. Additional information: This object is used by the IIO card to tell the peripheral firmware how many logical channels will be used by the card. This object can only be set once per physical channel. If an attempt is made to set it a subsequent time it is ignored and an return code of Protocol | Number ---------+------- UDP/IP | 17 IPX | 1000 MLC | 4660 Bytes 3 and 4 indicate the address family. The address family uses the same mapping as the BSD sockets address family. A list of interesting address family mappings include: Address Family | Number ---------------+------- Internet | 2 NetWare | 6 MLC | 22136
The format the fifth and following bytes is dependent on the address family. For the Internet address family, bytes 5 and 6 contain the port number, bytes 7 through 10 contain the IP address, and the following eight bytes are unused. For NetWare, bytes 5 through 8 are the network number, bytes 9 through 14 are the node number, and bytes 15 and 16 are the socket number. Additional information: The length of the binary value is zero if the instance of an object in the rpc-bind-protocol-address array is not in use. Returns status if attempting to access this object and there is no storage device is installed." ::= { settings-rpc 2 } rpc-bound-protocol-address OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "An array of Berkeley sockets style protocol addresses that the NFS service has been bound to successful. The format is that same as the array of RPC-BIND-PROTOCOL-ADDRESS of objects. Additional information: Returns status if attempting to access this object and there is no storage device is installed." ::= { status-rpc 3 } file-system-max-open-files OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The number of open files allowed at one time. Opening a file when the maximum number of files are currently open will fail. Additional information: Indicates the number of open files a personality (e.g. PCL or PostScript) is guaranteed to be able to open before the file system runs out of file handles. This object is between 1 and 500. Returns status if attempting to access this object and there is no storage device is installed." ::= { settings-file-system 2 } file-system-set-system-partition-writeable OBJECT-TYPE SYNTAX OCTET STRING ACCESS write-only STATUS optional DESCRIPTION "This object allows the system partition to be written to. It consists of a C structure containing the following fields: typedef struct { ubyte <>[8]; ubyte volumenumber; } fs_writeable_system_partition_t; which is described below: Bytes 0 - 7: contain the <> Byte 8 : is the volume number Access to this command is controlled by the <>. If the <> supplied is incorrect the command will fail. The volumenumber is a volume number of an existing system partition. Additional information: Returns status if attempting to access this object and there is no storage device is installed. Returns if the <> is incorrect or if the volume requested is not present." ::= { settings-file-system 6 } file-system-set-system-partition-readonly OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS optional DESCRIPTION "Changes a system partition to be READ-ONLY. The value is the volume number to change. If the volume number specified is NOT a system partition an error is returned. Additional information: Returns status if attempting to access this object and there is no storage device is installed. Returns if the volume requested is not present." ::= { settings-file-system 7 } file-system-delete-files OBJECT-TYPE SYNTAX OCTET STRING ACCESS write-only STATUS optional DESCRIPTION "Setting this object causes the specified filename to be deleted, after first validating that the authentication data is correct for the specified user ID. The format for this object is a C structure: typedef struct { sint32 UserId; uint16 AuthenticationDataLen ubyte AuthenticationData[] char Filename[]; } fs_delete_files_t; which is described below: Bytes 0 - 3: contains a user id represented as a multi-byte value that is stored in big-endian format, where the most significant byte occurs first. Bytes 4 - 5 : Length of the Athentication data that follows starting at offset 6. Stored as a multi-byte value that is stored in big-endian format, where the most significant byte occurs first. Bytes 6 - 6+AuthenticationDataLen : a ubyte array containing the Authentication data used to verify access for this operation. Bytes starting at offset (6+AuthenticationDataLen+1): A null terminated character array representing the ASCII file name to be deleted. The length of the string will be limited by the remaining space in the object. This string represents a fully-qualified path name which may specify a filename or a regular expression that may match multiple files (e.g /*.exe). Access to this command is controlled by the UserId and the authentication data. If the UserID or authentication data supplied is incorrect the command will fail. The device POS will specify any limitations to the length of the filename string, what constitutes a correct user ID, what constitutes correct authentication data, and the significance of any return values. Additional information: Setting this object causes the specified filename to be deleted, after first validating that the authentication data is correct for the specified user ID. This object is always present. The format for this object is a C structure: typedef struct { sint32 UserId; uint16 AuthenticationDataLen ubyte AuthenticationData[] char Filename[]; } fs_delete_files_t; Bytes 0 - 3: contains a user id represented as a multi-byte value that is stored in big-endian format, where the most significant byte occurs first. Bytes 4 - 5 : Length of the authentication data that follows starting at offset 6. Stored as a multi-byte value that is stored in big-endian format, where the most significant byte occurs first. Bytes 6 - 6+AuthenticationDataLen : a ubyte array containing the authentication data used to verify access for this operation. Bytes starting at offset (6+AuthenticationDataLen+1): A null terminated character array representing the ASCII file name to be deleted. The length of the string will be limited by the remaining space in the object. This string represents a fully-qualified path name which may specify a filename or a file-type regular expression that may match multiple files (e.g., /*.exe). Access to this command is controlled by the UserId and the authentication data. If the UserID or authentication data supplied is incorrect the command will fail. The device POS will specify any limitations to the length of the filename string, what constitutes a correct user ID, what constitutes correct authentication data, and the significance of any return values." ::= { settings-file-system 8 } file-system2-initialize-volume OBJECT-TYPE SYNTAX INTEGER { eInitializing(2) } ACCESS write-only STATUS optional DESCRIPTION "Setting this object to eInitializing causes file system 2 to be initialized. Reading this object indicates if the file system is currently being initialized. Additional information: The hrDeviceIndex value for the mass storage device is the same value that is used to index into the FILE-SYSTEM sub-tree. Since this product supports up to 3 physical mass storage device, and since the hrDeviceIndex for the mass storage devices will start at 2 if the mass storage device is installed, the FILE-SYSTEM2-INITIALIZE-VOLUME object will be the object that allows the mass storage device to be initialized that is the 1st device." ::= { file-system2 6 } file-system3-initialize-volume OBJECT-TYPE SYNTAX INTEGER { eInitializing(2) } ACCESS write-only STATUS optional DESCRIPTION "Setting this object to eInitializing causes file system 3 to be initialized. Reading this object indicates if the file system is currently being initialized. Additional information: The hrDeviceIndex value for the mass storage device is the same value that is used to index into the FILE-SYSTEM sub-tree. Since this product supports up to 3 physical mass storage device, and since the hrDeviceIndex for the mass storage devices will start at 2 if the mass storage device is installed, the FILE-SYSTEM3-INITIALIZE-VOLUME object will be the object that allows the mass storage device to be initialized that is the 2nd device." ::= { file-system3 6 } file-system4-initialize-volume OBJECT-TYPE SYNTAX INTEGER { eInitializing(2) } ACCESS write-only STATUS optional DESCRIPTION "Setting this object to eInitializing causes file system 4 to be initialized. Reading this object indicates if the file system is currently being initialized. Additional information: The hrDeviceIndex value for the mass storage device is the same value that is used to index into the FILE-SYSTEM sub-tree. Since this product supports up to 3 physical mass storage devices, and since the hrDeviceIndex for the mass storage devices will start at 2 if the mass storage device is installed, the FILE-SYSTEM4-INITIALIZE-VOLUME object will be the object that allows the mass storage device to be initialized that is the 3rd device." ::= { file-system4 6 } mass-storage-resource-change-counter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "A counter which changes when a mass storage based resource has been added or deleted. Additional information: The value of this counter changes each time the MASS-STORAGE-RESOURCE-CHANGED object is set to eTrue. The value also changes when the mass storage device is initialized. However, the value does not change when a mass storage device is removed and a different mass storage device is installed. Initializing all volumes sets this object back to the factory default value. A reboot sets this object back to the factory devalut value. Returns status if attempting to access this object and there is no storage device is installed." ::= { mass-storage-resources 1 } mass-storage-resource-changed OBJECT-TYPE SYNTAX INTEGER { eTrue(2) } ACCESS write-only STATUS optional DESCRIPTION "Setting to eTrue causes MASS-STORAGE-RESOURCE-CHANGE-COUNTER to be incremented. Additional information: Returns status if attempting to access this object and there is no storage device is installed." ::= { mass-storage-resources 2 } ram-disk-mode OBJECT-TYPE SYNTAX INTEGER { eOff(1), eAuto(3) } ACCESS read-write STATUS optional DESCRIPTION "Returns or controls RAM disk support. eOFF turns off the RAM disk functionality. eOn turns on the RAM disk functionality and creates a RAM disk whose size is controlled by the RAM-DISK-SIZE object. eAuto turns on the RAM disk functionality and creates a RAM disk size determined by the printer based on installed options and other memory related settings. Additional information: Returns or controls RAM disk support. eOFF turns off the RAM disk functionality. eAuto turns on the RAM disk functionality and creates a RAM disk size determined by the printer based on the amount of installed memory." ::= { settings-mass-storage-bd 1 } ram-disk-size OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns or controls the size of the RAM disk. The device POS specifies the minimum memory requirements. The object MAXIMUM-RAM-DISK-MEMORY specifies the maximum memory available for the RAM disk. Additional information: Returns the size of the RAM disk." ::= { settings-mass-storage-bd 2 } maximum-ram-disk-memory OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "This object's name is misleading. This object does not return the maximum configurable RAM disk size. Instead, it returns the maximum amount of memory, in bytes, that can used to increase the size of the RAM disk. Additional information: This object returns the maximum amount of additional memory that is available for increasing the size of the RAM disk." ::= { status-mass-storage-bd 1 } page-frame-memory-available OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Returns the abount of page-frame memory in bytes available in the system. Additional information: Total amount of onboard pageframe memory, in kilobytes, present in the printer." ::= { status-system 72 } mono-color-switching-mode OBJECT-TYPE SYNTAX INTEGER { eAutoSwitch(1), eMostlyColor(2), eMostlyMono(3) } ACCESS read-write STATUS optional DESCRIPTION "This object allows the user to view/change the color/mono switching mode for a device. Additional information: This object allows the user to view/change the color/mono switching mode for a device. The behavior of each setting may vary depending on the device. The value will be stored in NVRAM" ::= { settings-system 31 } device-configure-printer-parameters OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..256)) ACCESS read-write STATUS optional DESCRIPTION "Allow the printer to be configured as a duplex or simplex printer. There will be a <> encoded in this string and decoded by the printer firmware. If the <> check passes the printer will be configured accordingly. Additional information: Used to configure engines for duplex enabled or not. Encoded configuration string is passed in, which is decoded by firmware. Firmware verifies config. string is valid, and retrieves device Configuration data. Expandable to accommodate future products configuration needs." ::= { device-configure 12 } speed-energy-usage OBJECT-TYPE SYNTAX INTEGER { eFasterFirstPage(1), eSaveEnergy(2) } ACCESS read-write STATUS optional DESCRIPTION "Option to keep the fuser in a pre-warmed state to speed up first page out. Additional information: Option to keep the fuser in a pre-warmed state to speed up first page out." ::= { settings-system 50 } job-input-auto-continue-timeout OBJECT-TYPE SYNTAX INTEGER(-1..3600) ACCESS read-write STATUS optional DESCRIPTION "The number of seconds the device waits after a job related continuable error occurs before automatically continuing. An example job related continuable error is the job requesting a media size that is not available. After the timeout expires, the device will continue processing the job as if a continue event occurred, such as the front panel continue key being pressed. If the value is -1, the device does not automatically continue after a job related continuable error occurs. If the value is 0, the device immediately continues. If the value is greater than 0, the value represents the timeout value in seconds. Additional information: The number of seconds the device waits after a job related continuable error occurs before automatically continuing. An example job related continuable error is the job requesting a media size that is not available. After the timeout expires, the device will continue processing the job accourding to the action defined by JOB-INPUT-AUTO-CONTINUE-MODE. If the value is -1, the device does not automatically continue after a job related continuable error occurs. If the value is 0, the device immediately continues. If the value is greater than 0, the value represents the timeout value in seconds. The data for this object is stored in NVRAM." ::= { status-system 35 } job-input-auto-continue-mode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the device behavior when the desired media is not currently available. cCancelJob - The device cancels the job. The device POS should explain what happens if this item is not the only item in the collection. cAutoMediaSizeOverride - The device is allowed to substitute a different size media. cAutoMediaNameOverride - The device is allowed to substitute a different media name. cUSMediaSizeOverride - The device is allowed to substitute US media sizes (letter, etc.) for ISO media sizes (A4, etc.). cISOMediaSizeOverride - The device is allowed to substitute ISO media sizes (A4, etc.) for US media sizes (letter, etc.). Additional information: Returns or sets the device behavior when the desired media is not currently available. cCancelJob - The device cancels the job regardless of other item settings. cAutoMediaSizeOverride - The device is allowed to substitute a different size media. cAutoMediaNameOverride - The device is allowed to substitute a different media name. -- cUSMediaSizeOverride - The device is allowed to substitute -- US media sizes (letter, etc.) for ISO media sizes -- (A4, etc.). -- cISOMediaSizeOverride - The device is allowed to substitute -- ISO media sizes (A4, etc.) for US media sizes -- (letter, etc.). At least one bit of the collection must be set; setting this object to zero will cause a status of to be returned. This object describes the action that is performed when the JOB-INPUT-AUTO-CONTINUE-TIMEOUT expires. " ::= { status-system 36 } job-output-auto-continue-timeout OBJECT-TYPE SYNTAX INTEGER(-1..3600) ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the time that the printer will wait after an output bin becomes full and the printer is trying to deliver a sheet of media to that output bin. When the timeout expires, the job is processed according to the OUTBINn-OVERRIDE-MODE. A value of -1 indicates that the printer will wait for a continue event. A non-negative value is the number of seconds to wait. Additional information: Returns or sets the time that the printer will wait after an output bin becomes full and the printer is trying to deliver a sheet of media to that output bin. When the timeout expires, the job is processed according to the OUTBINn-OVERRIDE-MODE. A value of -1 indicates that the printer will wait for a continue event. A non- negative value is the number of seconds to wait." ::= { status-system 40 } model-number OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Identifies the device model number as listed in the HP corporate price list (e.g. C2121A for DeskJet 500C). The string is as specific as possible. Products should note in POS if the model number on the CPL changes but the device reports the previous model number. If the model number changes based on the installed options, the POS should indicate if only the base model number is returned, or if the device senses the installed options and returns the correct model number. If possible, encode the model number in a symbol set (like Roman-8) that matches the ASCII character set and limit the characters used to ASCII characters. Additional information: Identifies the device model number as listed in the HP corporate price list (e.g. C2121A for DeskJet 500C). The string is as specific as possible. The value of this object does not change based on the installed options. The default of this object is the same on all $product_str printers." ::= { id 1 } model-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..32)) ACCESS read-only STATUS optional DESCRIPTION "Identifies the device model name (e.g. ''DeskJet 1200C''). The string is as specific as possible. Capitalization and spacing should match family naming conventions. Products should note in POS if the model name on the HP corporate price list changes but the device reports the previous device name. If the model name changes based on the installed options, the POS should indicate if only the base model name is returned, or if the device senses the installed options and returns the correct model name. If possible, encode the model name in a symbol set (like Roman-8) that matches the ASCII character set and limit the characters used to ASCII characters. Additional information: Since the value of this object is frequently used in displaying a list of printers, it is kept relatively short in case systems have limited width for their display area. The model name does not change based on sensing of installed options." ::= { id 2 } formatter-serial-number OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "This object returns the formatter serial number for the device. The value returned from this object is the FORMATTERNUMBER system variable. If possible, encode the serial number in a symbol set (like Roman-8) that matches the ASCII character set and limit the characters used to ASCII characters. Additional information: Returns the formatter serial number, prefixed with the PML_UNICODE_PREFIX.." ::= { id 20 } engine-self-diagnostic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "The ENGINE-SELF-DIAGNOSTIC object reveals current engine failures; it returns a binary string of two-byte motor, clutch, solenoid, and sensor failure codes. Additional information: The ENGINE-SELF-DIAGNOSTIC object reveals current Engine Failures; it returns a BINARY string of two-byte Motor, Clutch, Solenoid and Sensor failure codes." ::= { test 7 } engine-parameter OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "The ENGINE-PARAMETER object returns a device specific set of engine parameters as a binary string of byte values. It will be necessary to have a decoder for each engine to interpret the data. Additional information: The ENGINE-PARAMETER object returns a device specific set of engine parameters as a BINARY string of byte values. It will be necessary to have a decoder for each engine to interpret the data." ::= { test 8 } default-media-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the media name that is used until the media name is changed by a print job command. Additional information: Returns or sets the media name that is used until the media name is changed by a print job command. This string must be one of the MEDIAn-NAME objects. This object is localized if the corresponding MEDIAn-NAME object is localized. The data for this object is stored in NVRAM." ::= { settings-pdl 22 } override-media-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "Sets a string identifying the media name that is to be used in place of the currently requested media. The substitution will continue until another media is selected. If set to a named media that is not currently available the requested media is not overridden. Additional information: When a request is received to print on a size and type of media that is not currently available, this object contains the desired media name as set by the print job. This object should be set to a media name that is currently available in the printer. If a paper mount request is not pending, attempting to get or set this object will cause to be returned. Setting this object to a string other than one of the MEDIAn-NAME objects (MEDIA-NAMES-AVAILABLE is applied) will cause a status of to be returned." ::= { settings-prt-eng 2 } override-media-size OBJECT-TYPE SYNTAX INTEGER { eUSExecutive(1), eUSLetter(2), eUSLegal(3), eLedger(11), eROC16K(17), eJISExecutive(18), eROC8K(19), eISOandJISA5(25), eISOandJISA4(26), eISOandJISA3(27), eJISB5(45), eJISB4(46), eISOB5(65), eJapanesePostcardDouble(72), eMonarch(80), eCommercial10(81), eInternationalDL(90), eInternationalC5(91), eInternationalB5(100), eCustom(101), eUSLetterR(258), eISOandJISA4R(282), eUnknownMediaSize(32767) } ACCESS read-write STATUS optional DESCRIPTION "Sets the media size that is to be used in place of the currently requested media size. Additional information: When a request is received to print on a size and type of media that is not currently available, this object contains the desired size as set by the print job. This object should be set to a media size that is currently available to the printer. If a paper mount request is not pending, attempting to get or set this object will cause to be returned." ::= { settings-prt-eng 3 } marking-agent-highlights-density-setting OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the marking agent highlights density setting for each of the marking agents installed. The value of this object is in the range of -5..+5. The Marking Agent (aka Print) density is the instantaneous amount of marking agent applied to the media while printing. A value of -5 has the lowest print density, yeilding a lighter pageA value of +5 the highest print density, yielding a darker page. Additional information: Returns or sets the marking agent highlights density setting for each of the marking agents installed. The value of this object is in the range of -5..+5. The Marking Agent (aka Print) density is the instantaneous amount of marking agent applied to the media while printing. A value of -5 has the lowest print density, yielding a lighter page. A value of +5 has the highest print density, yielding a darker page." ::= { marking-agent-density 2 } marking-agent-midtones-density-setting OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the marking agent midtones density setting for each of the marking agents installed. The value of this object is in the range of -5..+5. See MARKING-AGENT-HIGHLIGHTS-DENSITY-SETTING for a more specific description. Additional information: Returns or sets the marking agent midtones density setting for each of the marking agents installed. The value of this object is in the range of -5..+5. See MARKING-AGENT-HIGHLIGHTS-DENSITY-SETTING for a more specific description." ::= { marking-agent-density 3 } marking-agent-shadows-density-setting OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the marking agent shadows density setting for each of the marking agents installed. The value of this object is in the range of -5..+5. See MARKING-AGENT-HIGHLIGHTS-DENSITY-SETTING for a more specific description. Additional information: Returns or sets the marking agent shadows density setting for each of the marking agents installed. The value of this object is in the range of -5..+5. See MARKING-AGENT-HIGHLIGHTS-DENSITY-SETTING for a more specific description." ::= { marking-agent-density 4 } autocleaning-page-frequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Controls the number of pages between printing of the auto cleaning page (if enabled). Any device specific 'snap' behavior for this page interval will be specified in the device pos. Additional information: Controls the number of pages between printing of the auto cleaning page (if enabled). The legal values are 1000, 2000, 5000, 10000, and 20000. All other values will return OK_NEAREST_LEGAL_VALUE_SUBSTITUTED." ::= { settings-prt-eng 11 } autocleaning-page-size OBJECT-TYPE SYNTAX INTEGER { eUSLetter(2), eISOandJISA4(26) } ACCESS read-write STATUS optional DESCRIPTION "Controls the size of paper used to print the auto cleaning page (if enabled). Additional information: Controls the size of paper used to print the auto cleaning page (if enabled)." ::= { settings-prt-eng 12 } finisher-image-rotation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "This PML object will provide the additional image rotation that is applied to a printed job depending on the presence or absence of a finisher device or the value of the SVM_ALWAYS_MATCH_OUTPUT_ORIENTATION variable. Additional information: This PML object will provide the additional image rotation that is applied to a printed job depending on the presence or absence of a finisher device and/or the state of the IMAGE ROTATION menu element." ::= { settings-prt-eng 31 } total-color-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Total number of color pages printed by the device. Additional information: Total number of color pages printed by the device. The valid range of this object is 0 to 2^24-1. When the number of color pages printed exceeds the maximum color page count, the value will roll to zero. A duplexed sheet of media will cause the counter to be incremented by two." ::= { status-prt-eng 7 } duplex-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Total number of sheets of media that have been duplex printed. A sheet is counted if it travels through the duplex page path, regardless of whether or not marks are made on the page. The POS will indicate if the value is kept in NVRAM. Additional information: Total number of sheets of media that have been duplex printed. A sheet is counted if it travels through the duplex page path, regardless of whether or not marks are made on the page. This value is kept in NVRAM however the NVRAM value is only updated every 10 sheets. NOTE: The value returned by this object will be incremented every sheet but if power is lost between NVRAM updates up to 9 sheets of the count may be lost. The counter will be reset to zero after 16,777,215 (2^24-1) pages. " ::= { status-prt-eng 22 } print-engine-revision OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..16)) ACCESS read-only STATUS optional DESCRIPTION "Print engine revision string. Additional information: Print engine revision string. The symbol set for this string is Roman-8. " ::= { status-prt-eng 26 } printer-cal-dhalf-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Provides the page count when the last DHALF calibration occurred. A '-1' indicates that a calibration of this kind has not taken place yet. This object exists (and is meaningful) only in color printers. Additional information: Provides the page count when last DHALF calibration occurred. A -1 indicates that a calibration of this kind has not taken place yet. This object exists (and is meaningful) only in color printers." ::= { printer-calibration-dhalf 1 } printer-cal-dhalf-utc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Provides the time (in UTC - Universal Time Code format) when the last DHALF calibration occurred. This value could be zero if no calibration has taken place or if the printer lacked real-time. This object exists (and is meaningful) only in color printers. Additional information: Provides the time (in UTC - Universal Time Code format) when last DHALF calibration occurred. This value could be zero if no calibration has taken place and / or if the printer lacked real-time. This object exists (and is meaningful) only in color printers." ::= { printer-calibration-dhalf 2 } printer-cal-dhalf-data1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Provides a device specific set of DHalf calibration data as a binary string of byte values. It will be necessary to have a decoder for each engine to interpret the data. Additional information: Provides a device specific set of Dhalf calibration data as a binary string of byte values. It will be necessary to have a decoder for each engine to interpret the data." ::= { printer-cal-dhalf-data 1 } printer-cal-dhalf-data2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Provides a device specific set of DHalf calibration data as a binary string of byte values. It will be necessary to have a decoder for each engine to interpret the data. Additional information: Provides a device specific set of Dhalf calibration data as a binary string of byte values. It will be necessary to have a decoder for each engine to interpret the data." ::= { printer-cal-dhalf-data 2 } printer-cal-cpr-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Provides the page count when last CPR calibration occurred. A '-1' indicates that a calibration of this kind has not taken place yet. This object exists (and is meaningful) only in color printers. Additional information: Provides the page count when last CPR calibration occurred. A -1 indicates that a calibration of this kind has not taken place yet. This object exists (and is meaningful) only in color printers." ::= { printer-calibration-cpr 1 } printer-cal-cpr-utc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Provides the time (in UTC - Universal Time Code format) when the last CPR calibration occurred. This value could be zero if no calibration has taken place or if the printer lacked real-time. This object exists (and is meaningful) only in color printers. Additional information: Provides the time (in UTC - Universal Time Code format) when last CPR calibration occurred. This value could be zero if no calibration has taken place and / or if the printer lacked real-time. This object exists (and is meaningful) only in color printers." ::= { printer-calibration-cpr 2 } printer-cal-cpr-data OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "Provides a device specific set of CPR calibration data as a binary string of byte values. It will be necessary to have a decoder for each engine to interpret the data. Additional information: Provides a device specific set of CPR calibration data as a binary string of byte values. It will be necessary to have a decoder for each engine to interpret the data." ::= { printer-calibration-cpr 3 } input-tray-auto-select OBJECT-TYPE SYNTAX INTEGER { eOff(1), eOn(2) } ACCESS read-write STATUS optional DESCRIPTION "Indicates if the device will automatically try to load media from the next input media tray in the auto-select sequence (defined by each device) when it cannot load media from the current tray. Locked trays will not be permitted in the auto-select sequence. This object has no meaning if there is only one unlocked input media tray. Additional information: Indicates if the device will automatically try to load media from the next input media tray in the auto-select sequence (defined by each device) when it cannot load media from the current tray. Locked trays will not be permitted in the auto-select sequence. This object has no meaning if there is only one unlocked input media tray." ::= { settings-intray 2 } custom-paper-feed-dim OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Sets the printer's custom paper dimension in the feed direction (direction parallel to the direction of paper feeding). The value for this object is specified in micrometers or tenthousandths of an inch, depending upon the value of CUSTOM-PAPER-DIM-UNIT. The valid range is engine-dependent and should be documented in the POS for each product. Additional information: Get/Set custom paper dimension (height). The return/set value is either in micrometers or 10,000ths of inches. A tray has to be in custom switch or without media size sensor to be able to set the custom dimension. If it is successfully setting the dimension value, the size of a tray is set to CUSTOM." ::= { settings-intray 8 } custom-paper-xfeed-dim OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Sets the printer's custom paper dimension in the cross-feed direction (direction ninety degrees relative to the direction of paper feeding). The value for this object is specified in micrometers or tenthousandths of an inch, depending upon the value of CUSTOM-PAPER-DIM-UNIT. The valid range is engine-dependent and should be documented in the POS for each product. Additional information: Get/Set custom paper dimension (width). The return/set value is either in micrometers or 10,000ths of inches. A tray has to be in custom switch or without media size sensor to be able to set the custom dimension. If it is successfully setting the dimension value, the size of a tray is set to CUSTOM." ::= { settings-intray 9 } default-custom-paper-dim-unit OBJECT-TYPE SYNTAX INTEGER { eTenThousandthsOfInches(3), eMicrometers(4) } ACCESS read-write STATUS optional DESCRIPTION "The units of measure used to specify the width and height of the printer's default custom paper size. The unit of measure of eTenThousandthsOfInches is 0.0001 inches. Additional information: The units of measure used to specify the width and height of the printer's default custom paper size. The unit of measure of eTenThousandthsOfInches is 0.0001 inches." ::= { settings-intray 10 } default-custom-paper-feed-dim OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Sets the printer's default custom paper size dimension in the feed direction (direction parallel to the direction of paper feeding). The value for this object is specified in micrometers or tenthousandths of an inch, depending upon the value of DEFAULT-CUSTOM-PAPER-DIM-UNIT. The valid range is engine-dependent and should be documented in the POS for each product. Additional information: Sets the printer's default custom paper size dimension in the feed direction (direction parallel to the direction of paper feeding). The value for this object is specified in micrometers or tenthousandths of an inch, depending upon the value of DEFAULT-CUSTOM-PAPER-DIM-UNIT. The valid range is engine-dependent and should be documented in the POS for each product." ::= { settings-intray 11 } default-custom-paper-xfeed-dim OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Sets the printer's default custom paper size dimension in the cross-feed direction (direction ninety degrees relative to the direction of paper feeding). The value for this object is specified in micrometers or tenthousandths of an inch, depending upon the value of DEFAULT-CUSTOM-PAPER-DIM-UNIT. The valid range is engine-dependent and should be documented in the POS for each product. Additional information: Sets the printer's default custom paper size dimension in the cross-feed direction (direction ninety degrees relative to the direction of paper feeding). The value for this object is specified in micrometers or tenthousandths of an inch, depending upon the value of DEFAULT-CUSTOM-PAPER-DIM-UNIT. The valid range is engine-dependent and should be documented in the POS for each product." ::= { settings-intray 12 } input-tray-max-media-feed-dim OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The maximum physical media size in the feed direction of this input device expressed in units of measure specified by INPUT- TRAY-MIN-MAX-DIM-UNIT. A value of (-1) implies 'unlimited', a value of (-2) implies 'unknown'. Additional information: The maximum physical media size in the feed direction of this input device expressed in units of measure specified by PrtInputDimUnit. A value of (-1) implies 'unlimited', a value of (-2) implies 'unknown'. Refer to Printer Management Standards web page, http://bldlabs.boi.hp.com/BLDPrinterLab/Project/PrinterManagement, for more details in the original format of the Standard Printer MIB." ::= { settings-intray 14 } input-tray-max-media-xfeed-dim OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The maximum physical media size across the feed direction of a particular input device expressed in units of measure specified by INPUT-TRAY-MIN-MAX-DIM-UNIT. A value of (-1) implies 'unlimited', a value of (-2) implies 'unknown'. Additional information: The maximum physical media size across the feed direction of this input device expressed in units of measure specified by PrtInputDimUnit. A value of (-1) implies 'unlimited', a value of (-2) implies 'unknown'. Refer to Printer Management Standards web page, http://bldlabs.boi.hp.com/BLDPrinterLab/Project/PrinterManagement, f or more details in the original format of the Standard Printer MIB." ::= { settings-intray 15 } input-tray-min-media-feed-dim OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The minimum physical media size in the feed direction of a particular input device expressed in units of measure specified by PrtInputMinMaxDimUnit. A value of (-1) implies 'unlimited', a value of (-2) implies 'unknown'. Additional information: The minimum physical media size in the feed direction of this input device expressed in units of measure specified by PrtInputDimUnit. A value of (-1) implies 'unlimited', a value of (-2) implies 'unknown'. Refer to Printer Management Standards web page, http://bldlabs.boi.hp.com/BLDPrinterLab/Project/PrinterManagement, for more details in the original format of the Standard Printer MIB." ::= { settings-intray 16 } input-tray-min-media-xfeed-dim OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The minimum physical media size across the feed direction of a particular input device expressed in units of measure specified by PrtInputMinMaxDimUnit. A value of (-1) implies 'unlimited', a value of (-2) implies 'unknown'. Additional information: The minimum physical media size across the feed direction of this input device expressed in units of measure specified by PrtInputDimUnit. A value of (-1) implies 'unlimited', a value of (-2) implies 'unknown'. Refer to Printer Management Standards web page, http://bldlabs.boi.hp.com/BLDPrinterLab/Project/PrinterManagement, for more details in the original format of the Standard Printer MIB." ::= { settings-intray 17 } tray1-media-size-loaded OBJECT-TYPE SYNTAX INTEGER { eUSExecutive(1), eUSLetter(2), eUSLegal(3), eFoolscap(10), eStatement(15), eROC16K(17), eJISExecutive(18), eISOandJISA5(25), eISOandJISA4(26), eJISB5(45), eJapansePostcardDouble(72), eMonarch(80), eCommercial10(81), eInternationalDL(90), eInternationalC5(91), eInternationalB5(100), eCustom(101), eAnyCustomSize(32764), eAnySize(32765) } ACCESS read-write STATUS optional DESCRIPTION "Returns the media size that is currently configuredconfigured in tray #1. This object can be set to indicate the media size currently loaded, if the printer supports input trays that can not sense the media size. Complete list of supported media sizes along with their dimensions are listed in the ''Media Size Table'' near the end of this document. Additional information: Returns the media size that is currently configuredconfigured in tray #1. This object can be set to indicate the media size currently loaded, if the printer supports input trays that can not sense the media size. Complete list of supported media sizes along with their dimensions are listed in the ''Media Size Table'' near the end of this document." ::= { intray1 1 } tray1-phd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Provides the number of the Paper Handling Device that contains this input tray. Additional information: Provides the number of the Paper Handling Device that contains this input tray." ::= { intray1 12 } tray2-media-size-loaded OBJECT-TYPE SYNTAX INTEGER { eUSExecutive(1), eUSLetter(2), eUSLegal(3), eFoolscap(10), eROC16K(17), eJISExecutive(18), eISOandJISA5(25), eISOandJISA4(26), eJISB5(45), eCustom(101), eAnyCustomSize(32764), eAnySize(32765) } ACCESS read-write STATUS optional DESCRIPTION "Returns the media size that is currently configured in tray #2. Complete list of supported media sizes along with their dimensions are listed in the ''Media Size Table'' near the end of this document. Additional information: Returns the media size that is currently configured in tray #2." ::= { intray2 1 } tray2-phd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Provides the number of the Paper Handling Device that contains this input tray. Additional information: Provides the number of the Paper Handling Device that contains this input tray." ::= { intray2 12 } tray3-media-size-loaded OBJECT-TYPE SYNTAX INTEGER { eUSExecutive(1), eUSLetter(2), eUSLegal(3), eFoolscap(10), eROC16K(17), eJISExecutive(18), eISOandJISA5(25), eISOandJISA4(26), eJISB5(45), eCustom(101), eAnyCustomSize(32764), eAnySize(32765) } ACCESS read-write STATUS optional DESCRIPTION "Returns the media size that is currently configured in tray #3. Complete list of supported media sizes along with their dimensions are listed in the ''Media Size Table'' near the end of this document. Additional information: Returns the media size that is currently configured in tray #3." ::= { intray3 1 } tray3-phd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Provides the number of the Paper Handling Device that contains this input tray. Additional information: Provides the number of the Paper Handling Device that contains this input tray." ::= { intray3 12 } overflow-bin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the bin that will be used for additional sheets of media when the current bin is full and printing is allowed to continue. Additional information: Returns or sets the bin that will be used for additional sheets of media when the current bin is full and printing is allowed to continue. The data for this object is stored in NVRAM." ::= { settings-outbin 4 } outbin1-override-mode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the device behavior when this output bin condition causes printing to stop. cCancelJob - The device cancels the job. cOutbinFullOverride - The device sends subsequent media to the overflow bin. cOutbinAttentionOverride - The device ignores the attention condition and continues printing. cBinderAttentionOverride - The device ignores the binder attention condition and continues printing. Additional information: Returns or sets the device behavior when this output bin condition causes printing to stop. cCancelJob - The device cancels the job, regardless of other bit settings. cOutbinFullOverride - The device sends subsequent media to the overflow bin. If this bin is the overflow bin, this bit is ignored. cOutbinAttentionOverride - The device ignores the attention condition and continues printing. cBinderAttentionOverride - The device ignores the binder attention condition and continues printing. This object describes the action that is performed when the JOB-OUTPUT-AUTO-CONTINUE-TIMEOUT expires. If no bits are set, no override action is taken (the printer will continue to wait)." ::= { outbin1 9 } marker-density-calibration OBJECT-TYPE SYNTAX INTEGER { eNotCalibrating(1), eCalibrateALL(2), eCalibrateColor(3), eCalibrateHalftone(4), eCalibrateColorPlaneRegistration(5) } ACCESS read-write STATUS optional DESCRIPTION "Returns the calibration status or triggers a calibration cycle. All calibration procedures are used if set to eCalibrateALL. If set to eCalibrateColor then a full density engine calibration is triggered. If set to eCalibrateColorPlaneRegistration, then a Color Plane Registration calibration is triggered. If set to eCalibrateDrumPhaseAdjustment, then a Drum Phase Adjustment calibration is triggered. Note that eNotCalibrating and eCalibrateBlackOnly are read-only values. eNotCalibrating is returned when no calibrations are executing. eCalibrateBlackOnly is returned when a density engine calibration is executing while in MPACCO mode. Additional information: Returns the calibration status or triggers a calibration cycle. All calibration procedures are used if set to eCalibrateALL. If set to eCalibrateColor then a full density engine calibration is triggered. If set to eCalibrateHalftone, then a Halftone calibration is triggered. If set to eCalibrateColorPlaneRegistration, then a Color Plane Registration calibration is triggered. If set to eCalibrateDrumPhaseAdjustment, then a Drum Phase Adjustment calibration is triggered." ::= { settings-marking-agent 11 } media-names-available OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "The value of this object controls which of the MEDIAx-NAME objects are supported. If a bit is set to zero, then attempting to get or set the corresponding MEDIAx-NAME objects will return . Additional information: Setting a bit to one will cause the corresponding MEDIAn- objects to be available (attempting to access an unavailable object will return ). MEDIA1- objects are always present, as this is the default media. If this object is set to a value that does not include cMediaName2Available, that bit will be set and a status of will be returned." ::= { settings-print-media 1 } north-edge-offset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the number of 300 dpi dots by which the image is shifted. Shift is relative to the leading edge of the medium as the medium flows through the marking engine with the side to be imaged facing the observer. The leading edge is the North edge and the other edges are defined by the normal compass layout of directions with the compass facing the observer. The adjustment is for all pages printed. A positive value moves the image away from the leading edge of the medium. A negative value moves the image closer to the leading edge of the medium. The value 0 will return the image to its factory default position. Additional information: Returns or sets the number of 300 dpi dots by which the image is shifted. Shift is relative to the leading edge of the medium as the medium flows through the marking engine with the side to be imaged facing the observer. The leading edge is the North edge and the other edges are defined by the normal compass layout of directions with the compass facing the ob server. The adjustment is for all pages printed. A positive value moves the image away from the leading edge of the medium. A negative value moves the image closer to the leading edge of the medium. The value 0 will return the image to its factory default position. The value of this object is stored in NVRAM." ::= { settings-print-media 2 } media1-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 1 name. Additional information: The order of these objects is determined by the order of SysOD_MediaTypeEnum. The symbol set for this string is Roman-8. " ::= { media1 1 } media1-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 1. The length restriction is required to allow the media name to be displayed on the device's control panel. The device POS must state the maximum number of characters allowed. If the device also has a limitation on what characters in a character set can be used (e.g. only uppercase characters allowed), the POS should also state character restrictions. Additional information: The order of these objects is determined by the order of SysOD_MediaTypeEnum. Length restricted version of the media name 1. The length restriction is required to allow the media name to be displayed on the device's control panel. The maximum supported string length is 9 characters. If the user entered string is too long, the device will store the first 9 characters and will return the status. The characters must be in the range 20H to 7FH except 5C cannot be used. The default symbol set is Roman-8 for English; additional legal symbol sets are ISOLatin5, ISOLatin2 and Windows31J. Setting this object with characters outside of the range or of an illegal symbol set will cause an error status of to be returned. This string is localized according to prtConsoleLocalization. If this object represents a standard type, and the user attempts to set the object, 'OK Nearest Legal Value Substituted' will be returned, and the standard value is retained. If this object represents a user defined type, and the user attempts to set the object, then the set will be successfull." ::= { media1 2 } media1-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 1 that have been printed. The device POS should state whether this value is lost across a power cycle or kept in NVRAM. Additional information: Number of sheets of media 1 that have been printed. This page count is saved in NVRAM after every 10 pages. The maximum value is 4,294,967,295 which will never be reached in normal operation. The page count is incremented when a sheet of media is pulled from an input tray. A duplex printed sheet will cause this counter to be incremented by one." ::= { media1 3 } media1-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: Displays the engine processing characterstics that are applied to this media type." ::= { media1 4 } media2-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 2 name. Additional information: See MEDIA1-NAME." ::= { media2 1 } media2-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 2. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media2 2 } media2-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 2 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media2 3 } media2-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media2 4 } media3-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 3 name. Additional information: See MEDIA1-NAME." ::= { media3 1 } media3-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 3. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media3 2 } media3-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 3 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media3 3 } media3-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media3 4 } media4-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 4 name. Additional information: See MEDIA1-NAME." ::= { media4 1 } media4-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 4. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media4 2 } media4-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 4 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media4 3 } media4-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media4 4 } media5-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 5 name. Additional information: See MEDIA1-NAME." ::= { media5 1 } media5-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 5. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media5 2 } media5-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 5 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media5 3 } media5-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media5 4 } media6-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 6 name. Additional information: See MEDIA1-NAME." ::= { media6 1 } media6-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 6. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media6 2 } media6-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 6 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media6 3 } media6-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media6 4 } media7-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 7 name. Additional information: See MEDIA1-NAME." ::= { media7 1 } media7-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 7. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media7 2 } media7-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 7 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media7 3 } media7-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media7 4 } media8-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 8 name. Additional information: See MEDIA1-NAME." ::= { media8 1 } media8-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 8. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media8 2 } media8-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 8 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media8 3 } media8-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media8 4 } media9-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 9 name. Additional information: See MEDIA1-NAME." ::= { media9 1 } media9-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 9. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media9 2 } media9-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 9 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media9 3 } media9-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media9 4 } media10-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 10 name. Additional information: See MEDIA1-NAME." ::= { media10 1 } media10-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 10. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media10 2 } media10-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 10 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media10 3 } media10-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media10 4 } media11-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 11 name. Additional information: See MEDIA1-NAME." ::= { media11 1 } media11-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 11. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media11 2 } media11-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 11 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media11 3 } media11-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media11 4 } media12-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 12 name. Additional information: See MEDIA1-NAME." ::= { media12 1 } media12-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 12. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media12 2 } media12-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 12 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media12 3 } media12-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media12 4 } media13-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 13 name. Additional information: See MEDIA1-NAME." ::= { media13 1 } media13-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 13. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media13 2 } media13-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 13 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media13 3 } media13-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media13 4 } media14-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 14 name. Additional information: See MEDIA1-NAME." ::= { media14 1 } media14-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 14. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media14 2 } media14-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 14 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media14 3 } media14-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media14 4 } media15-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 15 name. Additional information: See MEDIA1-NAME." ::= { media15 1 } media15-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 15. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media15 2 } media15-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 15 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media15 3 } media15-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media15 4 } media16-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 16 name. Additional information: See MEDIA1-NAME." ::= { media16 1 } media16-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 16. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media16 2 } media16-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 16 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media16 3 } media16-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media16 4 } media17-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 17 name. Additional information: See MEDIA1-NAME." ::= { media17 1 } media17-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 17. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media17 2 } media17-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 17 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media17 3 } media17-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media17 4 } media18-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 18 name. Additional information: See MEDIA1-NAME." ::= { media18 1 } media18-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 18. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media18 2 } media18-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 18 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media18 3 } media18-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media18 4 } media19-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 19 name. Additional information: See MEDIA1-NAME." ::= { media19 1 } media19-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 19. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media19 2 } media19-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 19 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media19 3 } media19-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media19 4 } media20-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 20 name. Additional information: See MEDIA1-NAME." ::= { media20 1 } media20-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 20. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media20 2 } media20-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 20 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media20 3 } media20-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media20 4 } media21-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 21 name. Additional information: See MEDIA1-NAME." ::= { media21 1 } media21-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 21. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media21 2 } media21-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 21 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media21 3 } media21-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media21 4 } media22-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 22 name. Additional information: See MEDIA1-NAME." ::= { media22 1 } media22-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 22. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media22 2 } media22-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 22 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media22 3 } media22-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media22 4 } media23-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 23 name. Additional information: See MEDIA1-NAME." ::= { media23 1 } media23-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 23. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media23 2 } media23-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 23 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media23 3 } media23-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media23 4 } media24-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 24 name. Additional information: See MEDIA1-NAME." ::= { media24 1 } media24-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 24. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media24 2 } media24-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 24 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media24 3 } media24-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media24 4 } media25-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 25 name. Additional information: See MEDIA1-NAME." ::= { media25 1 } media25-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 25. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media25 2 } media25-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 25 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media25 3 } media25-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media25 4 } media26-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..24)) ACCESS read-write STATUS optional DESCRIPTION "Media 26 name. Additional information: See MEDIA1-NAME." ::= { media26 1 } media26-short-name OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..9)) ACCESS read-write STATUS optional DESCRIPTION "Length restricted version of the media name 26. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME." ::= { media26 2 } media26-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of sheets of media 26 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT." ::= { media26 3 } media26-engine-media-mode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the description for MEDIA1-ENGINE-MEDIA-MODE." ::= { media26 4 } engine-media-modes-supported1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "The list of engine media modes supported by the device. The modes are each separated by a comma character. An example string would be: 'Normal,Rough,Low,Vellum'. Additional information: The list of engine media modes supported by the device. The modes are each separated by a comma character. An example string would be: 'Normal,Rough,Low,Vellum'." ::= { media-modes 1 } media-number-of-type-supported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Indicates the maximum number of supported media types. Additional information: Indicates the number of supported media type. This also indicates which bit in MEDIA-NAMES-AVAILABLE is significant" ::= { media-types 1 } non-assured-oht-page-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "This is a count of the number of invalid (non-HP Laser Jet) transparencies that have been printed on. This value is incremented every time an invalid OHT is printed on It is reset whenever the fuser count is set to 0. Additional information: This is a count of the number of invalid (non HP Laser Jet) transparencies that have been printed on. This value is incremented every time an invalid OHT is printed on. It is reset whenever the fuser count is set to 0." ::= { media-counts 1 } media-size-west-edge-first-side-offset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the number of 300 dpi dots by which the image is shifted relative to the west edge of the medium (see NORTH-EDGE-OFFSET). The adjustment is for the first printed side of the medium only. A positive value moves the image away from the west edge of the medium. A negative value moves the image closer to the west edge of the medium. The value 0 will return the image to its factory default position. Additional information: Returns or sets the number of 300 dpi dots by which the image is shifted relative to the west edge of the medium (see NORTH-EDGE-OFFSET). The adjustment is for the first printed side of the medium only. A positive value moves the image away from the west edge of the medium. A negative value moves the image closer to the west edge of the medium. The value 0 will return the image to its factory default position. The values in the sub array index are from the media size table in the hpmib. This adjustment is done on a paper size by paper size basis. The standard PCL5 codes for paper size are used for the value used in the OID. Please see S_ARRAY_SUB1 for legal " ::= { media-size 2 } media-size-west-edge-second-side-offset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the number of 300 dpi dots by which the image is shifted relative to the west edge of the medium (see NORTH-EDGE-OFFSET). The adjustment is for the second printed side of the medium only. A positive value moves the image away from the west edge of the medium. A negative value moves the image closer to the west edge of the medium. The value 0 will return the image to its factory default position. Additional information: Returns or sets the number of 300 dpi dots by which the image is shifted relative to the west edge of the medium (see NORTH-EDGE-OFFSET). The adjustment is for the second printed side of the medium only. A positive value moves the image away from the west edge of the medium. A negative value moves the image closer to the west edge of the medium. The value 0 will return the image to its factory default position. The values in the sub array index are from the media size table in the hpmib. This adjustment is done on a paper size by paper size basis. The standard PCL5 codes for paper size are used for the value used in the OID. Please see S_ARRAY_SUB1 for legal values. The data for this object is stored in NVRAM." ::= { media-size 3 } media-size-west-edge-side-offset-by-tray OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Returns or sets the number of 300 dpi dots by which the image is shifted relative to the west edge of the medium (see NORTH-EDGE-OFFSET). A positive value moves the image away from the west edge of the medium. A negative value moves the image closer to the west edge of the medium. The value 0 will return the image to its factory default position. Each OID binding corresponds to a valid tray number for this product. There can be a maximum of 15 trays, a combination of internal and external trays. Products that support other combinations of trays will specify this information in the device pos. The data for this object is stored in NVRAM. Additional information: Returns or sets the number of 300 dpi dots by which the image is shifted relative to the west edge of the medium (see NORTH-EDGE-OFFSET). A positive value moves the image away from the west edge of the medium. A negative value moves the image closer to the west edge of the medium. The value 0 will return the image to its factory default position. Each OID binding corresponds to a valid tray number for this product. There can be a maximum of 15 trays, a combination of internal and external trays. Products that support other combinations of trays will specify this information in the device pos. The data for this object is stored in NVRAM." ::= { media-size 4 } color-supply-out-action OBJECT-TYPE SYNTAX INTEGER { eStop(1), eAutoContinueBlack(2) } ACCESS read-write STATUS optional DESCRIPTION "This PML object can be used to change the behavior of the printer when a Color Cartridge reaches OUT. When this PML Object is set to eStop, the printer will be offline when a Color Cartridge reaches OUT. When this PML object is set to eAutoContinueBlack, then the printer will continue printing in Mono provided the Black cartridge has not reached OUT. Additional information: This corresponds to the menu setting 'Color Supply Out'.This object can be changed by the control panel or by the PJL variable. It can have any of the following enumerated values- eStop(1), eAutoContinueBlack(2). " ::= { settings-system 34 } control-panel-supplies-status-message OBJECT-TYPE SYNTAX INTEGER { eShow(1), eDontShow(2) } ACCESS read-write STATUS optional DESCRIPTION "This PML object can be used to enable or disable supplies status messages from being displayed on the control panel. eShow - show the status messages on the control panel. eDontShow - do not show the status messages on the control panel. Additional information: . This PML Object can be used to enable or disable the supplies status messages from being displayed on the control panel. eShow Show the status messages on the control panel. eDontShow Do not show the status messages on the control panel." ::= { settings-system 44 } configurable-low-threshold-setting OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS optional DESCRIPTION "This PML object can be used to configure the low threshold for supplies. Additional information: This PML object can be used to configure the Low Threshold for Supplies." ::= { settings-prt-eng 24 } supplies-replace-action-at-setting OBJECT-TYPE SYNTAX INTEGER { eStopAtLow(1), eStopAtOut(2), eOverrideAtOut(4) } ACCESS read-write STATUS optional DESCRIPTION "This object can be used to change the setting of menu item REPLACE SUPPLIES (REPLACE CARTRIDGE on Mono). The behavior of the printer when a supply hits low changes in accordance with the setting of this PML object. eStopAtLow - printer will stop when a supply reaches low. eStopAtOut - printer will stop when a supply reaches out. eStopAtMaxLife - printer will continue to print past cartridge out until the drum inside the cartridge reaches out. This option is only supported on mono products). eOverrideAtOut printer will continue to print past out in override mode. This option is only supported on color products. This option is not writeable. That is, using this PML object the setting could be changed to any option other than eOverrideAtOut. Additional information: This PML object can be used to change the setting of the menu item REPLACE SUPPLIES. The behavior of the printer when a supply hits low changes in accordance with the setting of this PML Object. 1. eStopAtLow - Printer will stop when a supply reaches low. 2. eStopAtOut - Printer will stop when a supply reaches out. 3. eOverrideAtOut[Read-only, Color Products] - Printer will continue print past out in override mode." ::= { settings-prt-eng 25 } supply-out-user-configured-override-limit OBJECT-TYPE SYNTAX INTEGER(0..100000) ACCESS read-write STATUS optional DESCRIPTION "This PML object reports the user configured cartridge out override page limit. Additional information: This PML object reports the user configured cartridge out override limit." ::= { settings-prt-eng 26 } cartridge-out-override-control OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS optional DESCRIPTION "This PML object is used to control Cartridge Out Override feature. Additional information: This object is used for the following purposes: 1. Enable/disable cartridge out override through SUPPLIES_REPLACE_ACTION_AT_PML Object. 2. Enable/disable Toner Out Limit: When toner out limit is disabled using this PML Object, engine will not be taken offline when a cartridge reaches toner out. Engine will continue to print and will be in Override mode until other limits are reached. 3. Enable/disable CRG R&D Limit: When CRG R&D limit is disabled using this PML Object, engine will not be taken offline when CRG R&D limit for printing in override is reached for any out cartridge. Engine will continue to print and will be in Override mode until other limits are reached." ::= { settings-prt-eng 27 } supply-out-action-support OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "This object is used to determine if a particular capability that allows printing to continue after one or more cartridge has reached out is supported by the device. The collection bits include: cCartridgeOutOverride - indicates that continuing to print with an out cartridge in use is supported. cMonochromePrintingAfterColorCartridgeOut - indicates that continuing to print in monochrome after a color cartridge is out is supported. cPrintingToMaxLife - indicates that printing until 'max life' is reached is supported [monochrome only]. Additional information: This object is used to determine what capabilities are supported by the device for allowing printing to continue after one or more cartridges have reached out. The collection bits include: cCartridgeOutOverride - indicates that continuing to print with an out cartridge in use is supported. cMonochromePrintingAfterColorCartridgeOut - indicates that continuing to print with monochrome after a color cartridge is out is supported." ::= { status-prt-eng 48 } supply-out-device-state OBJECT-TYPE SYNTAX INTEGER { eNoSupplyOut(1), eOffline(2), eCartridgeOutOverride(3), eMonochromePrintingAfterColorCartridgeOut(4) } ACCESS read-only STATUS optional DESCRIPTION "This PML object indicates the current behavior of the device if one or more supplies have reached out. If no supply has reached out, the value of this PML object is eNoSupplyOut. If one or more supplies have reached out, the value of this PML object will indicate if the printer is online and if so what mode is being used to continue printing. Additional information: This object indicates the current behavior of the device if one or more supplies have reached out. The enums represent: eNoSupplyOut - No supplies have reached out. eOffline - Printer is offline since one or more supplies have reached out. eCartridgeOutOverride - The cartridge override out is active. eMonochromePrintingAfterColorCartridgeOut - Monochrome printing after a color cartridge out is active." ::= { status-prt-eng 49 } supply-after-out-state OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "This object is used to read and write the various status flags indicating whether the consumable was used after out. The collection bits supported include: cNotUsedAfterOut - indicates the consumable was not used in any capacity after out. If cUsedAfterOutInOverrideMode or cUsedAfterOutInMonoPrintingAfterColorOutMode is set, this flag will not be set. cInstalledWhileInOverrideMode - indicates the consumable was installed while Cartridge Out Override was activated. cUsedAfterOutInOverrideMode - indicates the consumable was used after out while Cartridge Out Override was activated. cInstalledWhileInMonoPrintingAfterColorOutMode - indicates the consumable was installed while MPACCO was activated. cUsedAfterOutInMonoPrintingAfterColorOutMode - indicates the consumable was used after out while MPACCO was activated. Additional information: This object is used to read the various status flags indicating whether the consumable was used after out. The collection bits include: cNotUsedAfterOut - indicates the consumable is not used after out. cUsedAfterOutInOverrideMode - indicates the consumable was used after out while cartridge out override was actiavted. cInstalledWhileInMonoPrintingAfterColorOutMode - indicates that the consumable was installed while MPACCO was activated. cUsedAfterOutInMonoPrintingAfterColorOutMode - indicates that the consumable was after out while MPACCO was activated." ::= { status-prt-eng 50 } consumable-status-web-service-access-data OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "This object is used to report Web Service Access Data. Additional information: This object is used to report Web Service Access Data." ::= { consumable-status 75 } consumable-status-web-service-access-control OBJECT-TYPE SYNTAX INTEGER { eUserControlledAccess(0), eForcedAccess(1) } ACCESS read-only STATUS optional DESCRIPTION "This object is used to report data that controls how web service access is enabled. Additional information: This object is used to report data that controls how web service access is enabled." ::= { consumable-status 76 } consumable-string-information OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..287)) ACCESS read-write STATUS optional DESCRIPTION "This object is used to read and write the string value that describes the consumable information." ::= { consumable-string 1 } consumable-string-information-reset OBJECT-TYPE SYNTAX INTEGER { ePresetToNVRAM(1) } ACCESS read-write STATUS optional DESCRIPTION "This object is used to reset (set back to factory default) or read the current status of the corresponding information string. When Set to eResetToDefault, this object can be used to reset the corresponding information object back to its factory default value. Setting this object with an enumerated value of eCustomized has no effect. When a Get operation is performed on this object it will return a value eResetToDefault if still set to its factory value. It will return eCustomized if the corresponding information value has been set to a custom value. Additional information: This object returns ePresetToNVRAM(1) if CONSUMABLE-STRING-INFORMATION is currently set to the default string. It will return eCustomized(2) otherwise. However, we can explicitly set this object only to ePresetToNVRAM(1) and not eCustomized(2)." ::= { consumable-string 2 } consumable-reorder-url OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS optional DESCRIPTION "This object is used to read and write the URL that can be used to reorder consumables for this device. This URL is set at the factory but can be updated by a reseller or third party. Additional information: The URL can be up to 64 characters long." ::= { consumables 2 } consumable-current-state OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "This PML object returns the current state of the particular consumable. cAuthLevel1 - Consumable is at Authentication Level 1 cAuthLevel2 - Consumable is at Authentication Level 2 cAuthLevel3 - Consumable is at Authentication Level 3 cGenuineHPUnsupported - Cartridge is GenuineHP intended for another product cDefectiveMemory - Cartridge has a defective memory tag cMissingMemory - Memory tag is missing from the cartridge cLowCondition - Consumable has reached the engine low threshold cOutCondition - Consumable has reached its out threshold cIncorrect - Cartridge inserted is not the correct one cMissing - Consumable is missing from the printer cConfigurableLow - Consumable has reached the configurable low threshold value cStatusArevalid - The status reported on other bits are valid only if the bit is set to 1. If it is 0, the values are invalid. These are the possible states and whenever the consumable is in any of these states, the appropriate bit will be set. The cLowCondition will be set when the consumable reaches the engine low threshold, and cConfigurableLow will be set when the consumable reaches the Configurable Low threshold value. For non-cartridge supplies only cLowCondition, cOutCondition, and cMissing will be supported. Additional information: This object returns the current state of the particular consumable. cAuthLevel1 - Consumable is at Authentication Level 1 cAuthLevel2 - Consumable is at Authentication Level 2 cAuthLevel3 - Consumable is at Authentication Level 3 cAuthLevel4 - Consumable is at Authentication Level 4 cGenuineHPUnsupported - Cartridge is GenuineHP intended for another product cDefectiveMemory - Cartridge has a Defective Memory cMissingMemory - Memory is Missing from the Cartridge cLowCondition - Consumable has reached its low threshold cOutCondition - Consumable has reached its out threshold cIncorrect - Cartridge inserted is not the correct one cMissing - Consumable is Missing from the Printer cConfigurableLow - Consumable has reached the configurable low threshold value cStatusAreValid - The Status reported on other bits are valid only if this bit is set to 1. If it is 0, the values are invalid. These are the possible states and whenever a Consumable is in any of these states, the appropriate bit will be set. For Non Cartridge Supplies only cLowCondition, cOutCondition and cMissing will be supported." ::= { consumables 7 } consumable-notification-status OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "This object is used to read and write the various status flags supported by this consumable. For Laserjet 4700 MFP the collection bits supported include: cClient1ReorderNotificationSent - indicates whether EWS (Embedded Web Server) has already sent the reorder notification e-mail for this consumable. This bit can be both read and written. cClient2ReorderNotificationSent - indicates whether WJA (Web Jet Admin) has already sent the reorder notification e-mail for this consumable. This bit can be both read and written. cClient3ReorderNotificationSent - for future implementation cClient4ReorderNotificationSent - for future implementation cClient5ReorderNotificationSent - for future implementation cClient1ReplaceNotificationSent - indicates whether EWS (Embedded Web Server) has already sent the replace notification e-mail for this consumable. This bit can be both read and written. cClient2ReplaceNotificationSent - indicates whether WJA (Web Jet Admin) has already sent the replace notification e-mail for this consumable. This bit can be both read and written. cClient3ReplaceNotificationSent - for future implementation cClient4ReplaceNotificationSent - for future implementation cClient5ReplaceNotificationSent - for future implementation Additional information: If the cartridge is deemed to be NonHP, then this object will not exist. This object will have 1 sub arrays for the consumable. The client1 and 2 currently are assingned to EWS and WJA the remaining client are reserved for the future third party pml tools. A client is requiered to set only his assigned bit for reorder or replace notification. A client using other client's bit for reorder replace will result in the other client being not able to set the notification. Ex: For EWS ReOrderNotification it will send 0x00010000 and For EWS ReplaceNotification it will send 0x00000001 For WJA ReOrderNotification it will send 0x00020000 and For WJA ReplaceNotification it will send 0x00000002" ::= { consumables 10 } consumable-pages-printed-with-supply OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "This PML object returns the number of pages printed with a cartridge consumable. This PML object returns the value that should be displayed under 'Pages Printed With This Supply' for cartridges in color products. Additional information: This PML object returns the number of pages printed with a Cartridge Consumable. This PML object returns the value that should be displayed underPages Printed With This Supply for Cartridges in Color products." ::= { consumables 11 } consumable-life-usage-units-remaining OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "This object reports the current estimate of the number of usage units that remain before this supply is depleted. An installed supply that cannot report such a number will return a value of -2. It is the reponsibility of the host application to query each supply in order to determine an overall device USAGE-UNITS-REMAINING number - the lowest value returned. The unit of measure for this life estimate is determined by reading the corresponding CONSUMABLE-LIFE-USAGE-UNITS object. Additional information: This object will return the Pages or Estimated Pages remaining for the speciffic supply requested by the leaf node of this object. DEFAULT value is given as NO_SPEC inorder to support Inca Cartridges. $product_str 3800 Cartridges - 6000 Inca Cartridges - 4000" ::= { consumables-life 1 } consumable-life-usage-units OBJECT-TYPE SYNTAX INTEGER { ePagesRemaining(1), eEstimatedPagesRemaining(2) } ACCESS read-only STATUS optional DESCRIPTION "This object reports current usage units in use by the corresponding CONSUMABLE-LIFE-USAGE-UNITS-REMAINING object. Additional information: This object returns the units that CONSUMABLE-LIFE-USAGE-UNITS-REMAINING is returned in. Either ePagesRemaining(1) or eEstimatedPagesRemaining(2)." ::= { consumables-life 2 } consumable-life-low-threshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "This object is used to report and modify a threshold value indicating the point in the life of a consumable or supply at which a transition to a LOW state will occur." ::= { consumables-life 3 } printer-average-marking-agent-units-per-gram OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "This object is used to read the marking agent units of measure per gram. This is typically a conversion factor for converting pixels of toner to grams. This pixels-per-gram value is used to calculate the estimated number of pages remaining for a given marking agent." ::= { printer-average 4 } printer-average-marking-agent-coverage-actual OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS optional DESCRIPTION "This object is used to read the actual average marking agent coverage for a given color plane. It is a real number that represents percent coverage and will read from 0 to 100%. This object will return the same value as PRINTER-AVERAGE-MARKING-AGENT-COVERAGE except under certain conditions which will be specified in the device POS." ::= { printer-average 5 } web-server-url OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS optional DESCRIPTION "A Universal Resource Locator (URL) from which the Embedded Web Server can be configured. Any limitation on the size of this URL will be specified in the device POS." ::= { settings-webserver 2 } web-server-security OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "Each collection bit represents a device or Embedded Web Server feature that can be enabled or disabled via this object." ::= { settings-webserver 3 } firmware-download-write-status-supported OBJECT-TYPE SYNTAX INTEGER { eFalse(1), eTrue(2) } ACCESS read-only STATUS optional DESCRIPTION "This object provides information on whether the printer has the ability to communicate the write-status of the firmware download while the download is taking place." ::= { firmware-download 1 } firmware-download-write-time OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "If the design of the firmware-download implementation does not allow PML interaction during the download process, this value provides an estimation of the time where the printer will not be able to engage in PML communication. Additional information: If the design of the firmware-download implementation does not allow PML interaction during the download process, this value provides an estimation of the time where the printer will not be able to engage in PML communication. The calculated time is expected to be 140 secs. However, this time may increase as high as 280 secs as the flash part nears the maximum flash count." ::= { firmware-download 2 } firmware-download-write-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Tells the number of times that firmware has been downloaded to the flash part. Additional information: Tells the number of times that firmware has been downloaded to the flash part. The default value will vary depending on how many times the firmware is rolled before shipping." ::= { firmware-download 3 } firmware-download-current-state OBJECT-TYPE SYNTAX INTEGER { eIdle(1), eReceivingImage(2), eReceivedImageError(3), eVerifyingImage(4), eVerifiedImageError(5), eWritingImage(6), eWritingImageError(7), eDownloadComplete(8), eOKtoShutDown(9), eCancelDownload(10), eShuttingDown(11) } ACCESS read-write STATUS optional DESCRIPTION "Provides the current or last reportable state of the firmware download process. The current state may not necessarily be the current state, but could be the post-mortem state." ::= { firmware-download 4 } firmware-download-maximum-write-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Reports the manufacturer specified number of times that firmware can be downloaded to the flash part. A value of -1 means that there is no limit. A value of 0 means that downloading firmware is not permitted by this part. Any other positive integer value corresponds to the number of times that firmware can be downloaded to the flash part. Additional information: Reports the manufacturer specified number of times that firmware can be downloaded to the flash part. A value of -1 means that there is no limit. A value of 0 means that downloading firmware is not permitted by this part. Any other positive integer value corresponds to the number of times that firmware can be downloaded to the flash part. The current maximum write count is 500. This may change as flash technology evolves." ::= { firmware-download 5 } firmware-download-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This returns the name of the printer. This should match the name in the header of the upgrade image being sent to the flash part. If the name does not match with the name returned then the image that we are attempting to download does not upgrade the printer firmware. Additional information: This object returns the HP name of the printer. This should match what is in the PJL header of the RFU job Web Jet Admin uses this to ensure the printer is available to be upgraded." ::= { firmware-download 6 } firmware-download-version OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This object will return a string value representing the current revision of firmware that the printer is operating with. This is used to determine if code needs to be upgraded when an firmware bundle comes in, in an upgrade job. Additional information: Web Jet Admin uses the version string that is returned to determine what peices of an RFU bundle need to be upgraded when an RFU job is being built. This objects will return the version string of the printer." ::= { firmware-download 7 } upgradable-devices-write-status-supported OBJECT-TYPE SYNTAX INTEGER { eFalse(1), eTrue(2) } ACCESS read-only STATUS optional DESCRIPTION "This object provides information on whether the upgradable device has the ability to communicate the write-status of the upgrade while the upgrade is taking place." ::= { upgradable-devices 1 } upgradable-devices-write-time OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "If the design of the device upgrade implementation does not allow PML interaction during the download process, this value provides an estimation of the time where the device will not be able to engage in PML communication. The time returned will depend upon what device is attempting to be upgraded." ::= { upgradable-devices 2 } upgradable-devices-write-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Tells the number of times that firmware for device X has been downloaded to the flash part. The default value will vary depending on how many times the firmware is rolled before shipping." ::= { upgradable-devices 3 } upgradable-devices-current-state OBJECT-TYPE SYNTAX INTEGER { eIdle(1), eReceivedImage(2), eReceivedImageError(3), eVerifiedImage(4), eVerifiedImageError(5), eWritingImage(6), eWritingImageError(7), eUpgradeComplete(8) } ACCESS read-only STATUS optional DESCRIPTION "Provides the current or last reportable state of the device upgrade process. The current state may not necessarily be the current state, but could be the post-mortem state." ::= { upgradable-devices 4 } upgradable-devices-max-write-count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Reports the manufacturer specified number of times that firmware for device X can be downloaded to the flash part. A value of -1 means that there is no limit. A value of 0 means that downloading firmware is not permitted by this part. Any other positive integer value corresponds to the number of times that the firmware for device X can be downloaded to the flash part. The current maximum write count is 500. This may change as flash technology evolves." ::= { upgradable-devices 5 } upgradable-devices-name OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This returns the name of the upgradable device. This should match the name in the header of the upgrade image being sent to the flash part. If the name does not match with any of the names returned then the device that we are attempting to upgrade is unavailable for upgrading. Additional information: This object returns the HP name of the printer and the upgradable devices. There is one Name object per upgradable device. This should match what is in the PJL header of the RFU job Web Jet Admin uses this to ensure the printer or device is available to be upgraded." ::= { upgradable-devices 6 } upgradable-devices-version OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This object will return a string value representing the current revision of firmware that device X is operating with. This is used to determine if code needs to be upgraded when a firmware bundle comes in, in an upgrade job. Additional information: Web Jet Admin uses the version string that is returned to determine what peices of an RFU bundle need to be upgraded when an RFU job is being built. This internal object will return the current version string of the printer or device that it corresponds to." ::= { upgradable-devices 7 } remote-upgrade-enable OBJECT-TYPE SYNTAX INTEGER { eOff(1), eOn(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables or disables the ability to upgrade the firmware associated with any device that is available to be upgraded. This will be set to on or off at the RFU level in that if this mode is on any available device can be upgraded and if this mode is off none of the devices can be upgraded. There is not an individual mode for each device. Trying to set this to a value other than eOn or eOff will cause an UnsupportedValue error to occur." ::= { upgradable-devices 8 } END