-- *********************************************************************** -- Module: hpicfOpenFlow.mib -- -- Copyright (C) 2012,2014-2017 Hewlett Packard Enterprise Development LP -- All Rights Reserved. -- -- The contents of this software are proprietary and confidential to -- the Hewlett Packard Enterprise Development LP. No part of this -- program may be photocopied, reproduced, or translated into another -- programming language without prior written consent of the -- Hewlett Packard Enterprise Development LP. -- -- Purpose: This file contains MIB definition of HP-ICF-OPENFLOW-MIB -- -- *********************************************************************** HP-ICF-OPENFLOW-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter64, Unsigned32 FROM SNMPv2-SMI TruthValue, RowStatus, DisplayString FROM SNMPv2-TC SnmpAdminString FROM SNMP-FRAMEWORK-MIB MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF InterfaceIndex, ifIndex FROM IF-MIB InetAddressType, InetAddress, InetPortNumber FROM INET-ADDRESS-MIB hpSwitch FROM HP-ICF-OID PortList FROM Q-BRIDGE-MIB VidList FROM HP-ICF-TC; hpicfOpenFlowMIB MODULE-IDENTITY LAST-UPDATED "201803270000Z" -- March 27, 2018 ORGANIZATION "HP Networking" CONTACT-INFO "Hewlett Packard Company 8000 Foothills Blvd. Roseville, CA 95747" DESCRIPTION "Added all option hpicfOpenFlowInstanceOverrideProtocol mib object." REVISION "201803270000Z" -- March 27, 2018 DESCRIPTION "The MIB module for configuring OpenFlow." REVISION "201707160000Z" -- July 16, 2017 DESCRIPTION "Added a mib object hpicfOpenFlowControllerSourceAddressType corresponding to the source IP when configuring a controller. Updated compliance." REVISION "201706180000Z" -- June 18, 2017 DESCRIPTION "Added a mib object hpicfOpenFlowControllerSourceAddress for source IP when configuring a controller." REVISION "201704280000Z" -- April 28, 2017 DESCRIPTION "Added traditionalPipeline option hpicfOpenFlowInstanceOverrideProtocol mib object." REVISION "201610250000Z" -- October 25, 2016 DESCRIPTION "Removed bfd protocol in hpicfOpenFlowInstanceOverrideProtocol mib object." REVISION "201610050000Z" -- October 05, 2016 DESCRIPTION "Added mib object hpicfOpenFlowInstanceMeterPrecedenceLevel." REVISION "201608060000Z" -- August 6, 2016 DESCRIPTION "Removed two protocols, dtiscp and webmacauth in hpicfOpenFlowInstanceOverrideProtocol mib object. Also modified the BITS numbering of other protocols." REVISION "201607310000Z" -- July 31, 2016 DESCRIPTION "Added mib object hpicfOpenFlowInstanceMissRuleDefaultAction hpicfOpenFlowInstanceOverrideProtocol hpicfOpenFlowInstancePktInVlanTagging" REVISION "201604210000Z" -- April 21, 2016 DESCRIPTION "Removed mib object hpicfOpenFlowInstanceGroupHWCounterAvailability." REVISION "201512100000Z" -- December 10, 2015 DESCRIPTION "Added new enum in following MIB object hpicfOpenFlowInstanceOperStatusReason, disabled enum is added in this MIB object" REVISION "201509290000Z" -- September 29, 2015 DESCRIPTION "The following MIB object changes in hpicfOpenFlowInstanceOperStatusReason, hardwareFailure is renamed to enableFailedInHardware. controllerVLANRemoved is removed" REVISION "201501110000Z" -- January 11, 2015 DESCRIPTION "Added support for OpenFlow MAC group tables in the pipeline" REVISION "201406040000Z" -- June 4, 2014 DESCRIPTION "Added mib objects hpicfOpenFlowInstanceMembers hpicfOpenFlowInstancePipelineModel hpicfOpenFlowInstanceDatapathDesc Deprecated the table hpicfOpenFlowInstanceMembershipTable and mib object hpicfOpenFlowIpControlTableMode. Deprecated groups are hpicfOpenFlowInstanceGroup hpicfOpenFlowInstanceMembershipGroup hpicfOpenFlowScalarsGroup. Added new groups hpicfOpenFlowInstanceGroup1 hpicfOpenFlowScalarsGroup1. Deprecated the compliance hpicfOpenFlowCompliance and added hpicfOpenFlowCompliance1." REVISION "201210010000Z" -- October 16, 2012 DESCRIPTION "Added support for OpenFlow Specification 1.3" REVISION "201202010000Z" -- February 01, 2012 DESCRIPTION "The initial version of this MIB module" ::= { hpSwitch 89} -- ------------------------------------------------------------- -- Start of MIB Objects -- ------------------------------------------------------------- hpicfOpenFlowNotifications OBJECT IDENTIFIER ::= { hpicfOpenFlowMIB 0 } hpicfOpenFlowObjects OBJECT IDENTIFIER ::= { hpicfOpenFlowMIB 1 } hpicfOpenFlowConformance OBJECT IDENTIFIER ::= { hpicfOpenFlowMIB 2 } -- -- MIB objects -- hpicfOpenFlowStatus OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2), disableWithClearConfig (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Global configuration to enable or disable OpenFlow on the device. The 'disableWithClearConfig' enum disables OpenFlow along with removing all the OpenFlow related configuration." DEFVAL { disable } ::= { hpicfOpenFlowObjects 1} ---------------------------------------------------------- -- OpenFlow instance table ---------------------------------------------------------- hpicfOpenFlowInstanceTable OBJECT-TYPE SYNTAX SEQUENCE OF HpicfOpenFlowInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that is used create an OpenFlow instance. For maximum number of OpenFlow instances that can be supported, refer to hpicfOpenFLowMaxInstances MIB object." ::= { hpicfOpenFlowObjects 4 } hpicfOpenFlowInstanceEntry OBJECT-TYPE SYNTAX HpicfOpenFlowInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of objects that are used to create an OpenFlow instance." INDEX { hpicfOpenFlowInstanceName} ::= { hpicfOpenFlowInstanceTable 1 } HpicfOpenFlowInstanceEntry ::= SEQUENCE { hpicfOpenFlowInstanceName SnmpAdminString, hpicfOpenFlowInstanceAdminStatus INTEGER, hpicfOpenFlowInstanceListenPortCfg TruthValue, hpicfOpenFlowInstanceListenPort InetPortNumber, hpicfOpenFlowInstanceListenPortIsOobm TruthValue, hpicfOpenFlowInstanceMode INTEGER, hpicfOpenFlowInstanceFlowLocationMode INTEGER, hpicfOpenFlowConnectionInterruptionMode INTEGER, hpicfOpenFlowInstanceHwRateLimit Integer32, hpicfOpenFlowInstanceSwRateLimit Integer32, hpicfOpenFlowInstanceDatapathID Counter64, hpicfOpenFlowInstanceNumOfHwFlows Counter64, hpicfOpenFlowInstanceNumOfSwFlows Counter64, hpicfOpenFlowInstanceOperStatus INTEGER, hpicfOpenFlowInstanceMaxBackOffInterval Unsigned32, hpicfOpenFlowInstanceRowStatus RowStatus, hpicfOpenFlowInstanceProbeInterval Unsigned32, hpicfOpenFlowInstanceProtoVersion INTEGER, hpicfOpenFlowInstanceProtoVersionOnly TruthValue, hpicfOpenFlowInstanceNumOfSwFlowTable Unsigned32, hpicfOpenFlowInstanceOperStatusReason INTEGER, hpicfOpenFlowInstanceEgressOnlyPorts PortList, hpicfOpenFlowInstanceCapabilities BITS, hpicfOpenFlowInstanceHwTableMissCount Counter64, hpicfOpenFlowInstanceTableModel INTEGER, hpicfOpenFlowInstanceMembers VidList, hpicfOpenFlowInstancePipelineModel INTEGER, hpicfOpenFlowInstanceDatapathDesc DisplayString, hpicfOpenFlowInstanceSourceMacGrpTable INTEGER, hpicfOpenFlowInstanceDestMacGrpTable INTEGER, hpicfOpenFlowInstanceMissRuleDefaultAction INTEGER, hpicfOpenFlowInstanceOverrideProtocol BITS, hpicfOpenFlowInstancePktInVlanTagging INTEGER } hpicfOpenFlowInstanceName OBJECT-TYPE SYNTAX SnmpAdminString(SIZE(1..32)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Unique name given to an OpenFlow instance. The instance name 'aggregate' is special case denoting switch functioning as OpenFlow switch. The instance name allows lowercase alphanumeric characters and the special character underscore." ::= { hpicfOpenFlowInstanceEntry 1} hpicfOpenFlowInstanceAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to administratively enable or disable an OpenFlow instance. This MIB object can be set to 'enable' only when either hpicfOpenFlowInstanceListenPortCfg has been set to 'true' or atleast one controller is associated with this instance." DEFVAL { disable } ::= { hpicfOpenFlowInstanceEntry 2} hpicfOpenFlowInstanceListenPortCfg OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates if a listen-port is configured on this OpenFlow instance." DEFVAL { false } ::= { hpicfOpenFlowInstanceEntry 3} hpicfOpenFlowInstanceListenPort OBJECT-TYPE SYNTAX InetPortNumber MAX-ACCESS read-create STATUS current DESCRIPTION "Port number for the listen-port on the OpenFlow instance. A valid port number is between 1024 and 65534 inclusive." DEFVAL { 6633 } ::= { hpicfOpenFlowInstanceEntry 4} hpicfOpenFlowInstanceListenPortIsOobm OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates if a listen-port is configured for this OpenFlow instance over OOBM(Out Of Band Management) interface. This MIB object will be applicable only if there is a physical OOBM port on the device." DEFVAL { false } ::= { hpicfOpenFlowInstanceEntry 5} hpicfOpenFlowInstanceMode OBJECT-TYPE SYNTAX INTEGER { active(1), passive(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object allows the user to specify the mode of OpenFlow operation for an instance. In active mode, new flows get redirected to the OpenFlow controller. In passive mode, new flows are not sent to the OpenFlow controller.This object is applicable only for an OpenFlow version 1.0 instance." DEFVAL { active } ::= { hpicfOpenFlowInstanceEntry 6} hpicfOpenFlowInstanceFlowLocationMode OBJECT-TYPE SYNTAX INTEGER { hardwareOnly (1), hardwareAndSoftware (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object specifies if the flows for this instance will be located in hardware only or in hardware and software. By default, flows will be located in hardware and software.This object is applicable only for an OpenFlow version 1.0 instance." DEFVAL { hardwareAndSoftware } ::={ hpicfOpenFlowInstanceEntry 7} hpicfOpenFlowConnectionInterruptionMode OBJECT-TYPE SYNTAX INTEGER { failSecure (1), failStandalone (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This MIB object is used to specify the type of fallback when the switch loses connection with the controller. In fail-secure mode, packets and messages destined to the current controller are dropped. Flows should continue to expire according to their timeouts in fail-secure mode. In fail-standalone mode, the switch acts as a legacy Ethernet switch or router." REFERENCE "OpenFlow Spec-v1.1.0, Section 5.3" DEFVAL { failSecure } ::= { hpicfOpenFlowInstanceEntry 8} hpicfOpenFlowInstanceHwRateLimit OBJECT-TYPE SYNTAX Integer32 UNITS "kilobits per second" MAX-ACCESS read-create STATUS current DESCRIPTION "This object limits the bandwidth per module in kilobits per second, that this OpenFlow instance can utilize. This implementation supports a minimum rate limit of 0 kbps and a maximum rate limit of 10000000 kbps." ::= { hpicfOpenFlowInstanceEntry 9} hpicfOpenFlowInstanceSwRateLimit OBJECT-TYPE SYNTAX Integer32 UNITS "packets per second" MAX-ACCESS read-create STATUS current DESCRIPTION "This object limits the number of packets per second for each module, that this instance can send to the software path on the CPU. Increasing the software rate limit would increase CPU consumption and may impact the system performance. For maximum number of packets per second for each module, that an OpenFlow instance can send to the software path on the CPU, refer to hpicfOpenFLowInstanceMaxSwRateLimit MIB object." DEFVAL { 100 } ::= { hpicfOpenFlowInstanceEntry 10} hpicfOpenFlowInstanceDatapathID OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Datapath ID(DPID) uniquely identifies a datapath between this instance and the controller. Its lower 48-bits are intended for switch MAC address, while the upper 16-bits are defined by the implementation." REFERENCE "OpenFlow Spec-v1.1.0, Appendix A.3.1" ::= { hpicfOpenFlowInstanceEntry 11} hpicfOpenFlowInstanceNumOfHwFlows OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of hardware flows in this OpenFlow instance." ::= { hpicfOpenFlowInstanceEntry 12} hpicfOpenFlowInstanceNumOfSwFlows OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of software flows in this OpenFlow instance." ::= { hpicfOpenFlowInstanceEntry 13} hpicfOpenFlowInstanceOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to determine the operational state of an OpenFlow instance. The reason for operational status to be down is specified by the hpicfOpenFlowInstanceOperStatusReason MIB." ::= { hpicfOpenFlowInstanceEntry 14} hpicfOpenFlowInstanceMaxBackOffInterval OBJECT-TYPE SYNTAX Unsigned32(1..3600) UNITS "seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "Interval between two consecutive attempts made by an instance to reconnect to a controller increases exponentially till it reaches the value specified by this MIB object. All subsequent attempts use this value as the interval between retries." DEFVAL { 60 } ::= { hpicfOpenFlowInstanceEntry 15} hpicfOpenFlowInstanceRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row status for this table." ::= { hpicfOpenFlowInstanceEntry 16} hpicfOpenFlowInstanceProbeInterval OBJECT-TYPE SYNTAX Unsigned32(1..3600) UNITS "seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "This MIB object specifies the interval between two consecutive probes sent from an instance to the controller. This MIB value also determines how soon the instance will enter the connection interruption mode. If the instance does not hear a reply from the controller for three consecutive probes, it will flag the controller as unreachable and enter connection interruption mode." DEFVAL { 10 } ::= { hpicfOpenFlowInstanceEntry 17} hpicfOpenFlowInstanceProtoVersion OBJECT-TYPE SYNTAX INTEGER { v1dot0 (1), v1dot3 (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This MIB object specifies the OpenFlow instance protocol version." DEFVAL { v1dot3 } ::= { hpicfOpenFlowInstanceEntry 18} hpicfOpenFlowInstanceProtoVersionOnly OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "Setting this MIB object to true will support only the specific version mentioned by hpicfOpenFlowInstanceProtoVersion MIB and not compatible with lower versions." DEFVAL { false } ::= { hpicfOpenFlowInstanceEntry 19} hpicfOpenFlowInstanceNumOfSwFlowTable OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This MIB object specifies the number of software flow tables for this OpenFlow instance. The maximum value supported is 8. This object is applicable only for an OpenFlow version 1.3 instance." DEFVAL { 1 } ::= { hpicfOpenFlowInstanceEntry 20} hpicfOpenFlowInstanceOperStatusReason OBJECT-TYPE SYNTAX INTEGER{ notApplicable(1), hardwareResourcesUnavailable(2), memberVLANNotConfigured(3), memberVLANRemoved(4), noValidPortsInMemberVLAN(5), controllerVLANNotConfigured(6), enableFailedInHardware(7), disabled(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object specifies the reason for hpicfOpenFlowInstanceOperStatus to be down." ::= { hpicfOpenFlowInstanceEntry 21} hpicfOpenFlowInstanceEgressOnlyPorts OBJECT-TYPE SYNTAX PortList MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object specifies the list of egress only ports for this OpenFlow instance." ::= { hpicfOpenFlowInstanceEntry 22} hpicfOpenFlowInstanceCapabilities OBJECT-TYPE SYNTAX BITS { flowStatistics (0), tableStatistics (1), portStatistics (2), groupStatistics (3), meterStatistics (4), blockPorts (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object specifies the instance capabilities exchanged with the controller." ::= { hpicfOpenFlowInstanceEntry 23} hpicfOpenFlowInstanceHwTableMissCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object specifies the number of packets which do not match any rules in the hardware table. This object is applicable only for an OpenFlow version 1.0 instance." ::= { hpicfOpenFlowInstanceEntry 24} hpicfOpenFlowInstanceTableModel OBJECT-TYPE SYNTAX INTEGER { none(1), singleTable (2), policyEngineAndSoftware (3), ipControlWithPolicyEngineAndSoftware (4), customPipeline (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object determines the table model of an OpenFlow instance." ::= { hpicfOpenFlowInstanceEntry 25} hpicfOpenFlowInstanceMembers OBJECT-TYPE SYNTAX VidList MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object is used to add member VLANs to an OpenFlow instance." ::= { hpicfOpenFlowInstanceEntry 26 } hpicfOpenFlowInstancePipelineModel OBJECT-TYPE SYNTAX INTEGER { none(0), standardMatch(1), ipcontrolTable(2), customPipeline(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object is used to configure the openflow instance pipeline model. A value of 0(none) indicates no table pipeline model which is equal to standard match. A value of 1(standardMatch) enables an instance in advertising its policy-engine and software tables. A value of 2(ipControlTable) enables an OpenFlow 1.3 instance in advertising its IP control table. A value of 3(customPipeline) enables an OpenFlow controller to create a custom OpenFlow table pipeline in the OpenFlow 1.3 instance." DEFVAL { none } ::= { hpicfOpenFlowInstanceEntry 27} hpicfOpenFlowInstanceDatapathDesc OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object is a user-defined description of the data path. If not set, hpicfOpenFlowInstanceName is used." ::= { hpicfOpenFlowInstanceEntry 28 } hpicfOpenFlowInstanceSourceMacGrpTable OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to enable or disable the source MAC group table in the OpenFlow pipeline. This MIB object can be set to 'enable' only on one instance." DEFVAL { disable } ::= { hpicfOpenFlowInstanceEntry 29} hpicfOpenFlowInstanceDestMacGrpTable OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to enable or disable the destination MAC group table in the OpenFlow table. This MIB object can be set to 'enable' only on one instance." DEFVAL { disable } ::= { hpicfOpenFlowInstanceEntry 30} hpicfOpenFlowInstanceMissRuleDefaultAction OBJECT-TYPE SYNTAX INTEGER { none(0), drop(1), normal(2), ctrl(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object is used to configure the flow miss action associated with the instance. A value of 0(none) indicates no flow miss action specified, which is to drop all unknown packets. A value of 1(drop) enables an instance to drop all unknown packets. A value of 2(normal) enables an instance to forward all unknown packets using non-OpenFlow pipeline. A value of 3(ctrl) enables an instance to forward all unknown packets to the OpenFlow controller." DEFVAL { none } ::= { hpicfOpenFlowInstanceEntry 31} hpicfOpenFlowInstanceOverrideProtocol OBJECT-TYPE SYNTAX BITS { stp(0), gvrp(1), mvrp(2), lacp(3), dot1x(4), udld(5), loopprotect(6), pvst(7), smartlink(8), dldp(9), bonjour(10), traditionalPipeline(11), all(31) } MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object is used to configure the Override protocol associated with the instance." ::= { hpicfOpenFlowInstanceEntry 32} hpicfOpenFlowInstancePktInVlanTagging OBJECT-TYPE SYNTAX INTEGER { default(0), inputForm(1), tagAlways(2), untagAlways(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object is used to configure the 802.1q tagging property for a packet encapsulated inside the OpenFlow packet-in header. A value of 0 (default) indicates the default behavior which is the packet encapsulated inside a packet-in message will be tagged in the following cases a) the instance type is aggregate. b) the instance is a named instance with more than one member VLAN. c) the instance is a named instance and the packet was received with a tag. It will be untagged in all other cases. A value of 1 (inputForm) directs the instance to send the encapsulated packet as it was received on the physical port. A value of 2 (tagAlways) directs the instance to send the encapsulated packet always with an 802.1q tag irrespective of how it was received on the physical port. A value of 3 (untagAlways) directs the instance to send the encapsulated packet always without an 802.1q tag irrespective of how it was received on the physical port." DEFVAL { default } ::= { hpicfOpenFlowInstanceEntry 33} ---------------------------------------------------------- -- OpenFlow member table for OpenFlow instances ---------------------------------------------------------- hpicfOpenFlowInstanceMembershipTable OBJECT-TYPE SYNTAX SEQUENCE OF HpicfOpenFlowInstanceMembershipEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Table used to add members to OpenFlow instances. This table is deprecated and instead object hpicfOpenFlowInstanceMembers is used to configure members for an OpenFlow instance." ::= { hpicfOpenFlowObjects 5 } hpicfOpenFlowInstanceMembershipEntry OBJECT-TYPE SYNTAX HpicfOpenFlowInstanceMembershipEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A set of objects that are used to add members to an OpenFlow instance." INDEX { hpicfOpenFlowInstanceName, ifIndex } ::= { hpicfOpenFlowInstanceMembershipTable 1 } HpicfOpenFlowInstanceMembershipEntry ::= SEQUENCE { hpicfOpenFlowInstanceMembershipRowStatus RowStatus } hpicfOpenFlowInstanceMembershipRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Row status for this member." ::= {hpicfOpenFlowInstanceMembershipEntry 2} ---------------------------------------------------------- -- OpenFlow controller table for OpenFlow instances ---------------------------------------------------------- hpicfOpenFlowControllerTable OBJECT-TYPE SYNTAX SEQUENCE OF HpicfOpenFlowControllerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table used to configure controllers. For maximum number of OpenFlow controllers that can be supported, refer to hpicfOpenFlowMaxControllers MIB object." ::= { hpicfOpenFlowObjects 6 } hpicfOpenFlowControllerEntry OBJECT-TYPE SYNTAX HpicfOpenFlowControllerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of objects that are used to configure OpenFlow Controllers." INDEX { hpicfOpenFlowControllerID} ::= { hpicfOpenFlowControllerTable 1 } HpicfOpenFlowControllerEntry ::= SEQUENCE { hpicfOpenFlowControllerID Integer32, hpicfOpenFlowControllerInetAddressType InetAddressType, hpicfOpenFlowControllerInetAddress InetAddress, hpicfOpenFlowControllerPort InetPortNumber, hpicfOpenFlowControllerInterface InterfaceIndex, hpicfOpenFlowControllerRowStatus RowStatus, hpicfOpenFlowControllerSourceAddressType InetAddressType, hpicfOpenFlowControllerSourceAddress InetAddress } hpicfOpenFlowControllerID OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Unique ID given to a Controller. This will be associated with an instance through hpicfOpenFlowInstanceControllerTable." ::= { hpicfOpenFlowControllerEntry 1} hpicfOpenFlowControllerInetAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "Address type of this controller. This implementation supports only ipv4 type." ::= {hpicfOpenFlowControllerEntry 2} hpicfOpenFlowControllerInetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-create STATUS current DESCRIPTION "IP Address of the controller." ::= {hpicfOpenFlowControllerEntry 3} hpicfOpenFlowControllerPort OBJECT-TYPE SYNTAX InetPortNumber MAX-ACCESS read-create STATUS current DESCRIPTION "The port over which the controller can be reached." ::= {hpicfOpenFlowControllerEntry 4} hpicfOpenFlowControllerInterface OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "This MIB object specifies an interface over which the controller is reachable." ::= { hpicfOpenFlowControllerEntry 5} hpicfOpenFlowControllerRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row status for this table. The hpicfOpenFlowControllerInetAddress and hpicfOpenFlowControllerInterface MIB objects have to be set to valid values to move this object to 'active' state. This conceptual row can be deleted only if the corresponding controller association is removed from the hpicfOpenFlowInstanceControllerTable." ::= {hpicfOpenFlowControllerEntry 6} hpicfOpenFlowControllerSourceAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "Address type of the Source IP. This implementation supports only ipv4 type." ::= {hpicfOpenFlowControllerEntry 7} hpicfOpenFlowControllerSourceAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Source IP address to use when connecting to the controller." ::= {hpicfOpenFlowControllerEntry 8} ---------------------------------------------------------- -- OpenFlow Instance-Controller Connection State table ---------------------------------------------------------- hpicfOpenFlowInstanceControllerTable OBJECT-TYPE SYNTAX SEQUENCE OF HpicfOpenFlowInstanceControllerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table that contains objects for connection state and status between an OpenFlow instance and a controller." ::= { hpicfOpenFlowObjects 8 } hpicfOpenFlowInstanceControllerEntry OBJECT-TYPE SYNTAX HpicfOpenFlowInstanceControllerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of objects used to monitor the status and state of connection between an OpenFlow instance and controller." INDEX { hpicfOpenFlowInstanceName, hpicfOpenFlowControllerID } ::= { hpicfOpenFlowInstanceControllerTable 1 } HpicfOpenFlowInstanceControllerEntry ::= SEQUENCE { hpicfOpenFlowInstanceControllerStatus INTEGER, hpicfOpenFlowInstanceControllerState INTEGER, hpicfOpenFlowInstanceControllerRole INTEGER, hpicfOpenFlowInstanceControllerConnSecure TruthValue, hpicfOpenFlowInstanceControllerRowStatus RowStatus } hpicfOpenFlowInstanceControllerStatus OBJECT-TYPE SYNTAX INTEGER { connected (1), disconnected (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Connection status between an OpenFlow instance and a controller." ::= {hpicfOpenFlowInstanceControllerEntry 1} hpicfOpenFlowInstanceControllerState OBJECT-TYPE SYNTAX INTEGER { void(1), backoff(2), connecting(3), active(4), idle(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Connection state between an OpenFlow instance and a controller. The state 'void' implies that there is no connection. The state 'backoff' represents a state where the device is attempting to reconnect to the controller at increasing intervals of time. The state 'connecting' represents a state where the device is in the process of connecting to the controller. The state 'active' implies that a connection has been established and that the controller is responsive. The state 'idle' implies that the connection is idle and waiting for a response." ::= {hpicfOpenFlowInstanceControllerEntry 2} hpicfOpenFlowInstanceControllerRole OBJECT-TYPE SYNTAX INTEGER { equal (1), conductor (2), member (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Role of a controller in an instance. The default role of a controller is equal. In this role, the controller has full access to the switch and is equal to other controllers in the same role. In member role, the controller has read-only access to the switch. The conductor role is similar to equal and has full access to the switch, the difference is that the switch ensures it is the only controller in this role. When a controller changes its role to conductor, the switch changes all other controllers with the role conductor to have the role member." ::= {hpicfOpenFlowInstanceControllerEntry 3} hpicfOpenFlowInstanceControllerConnSecure OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates if the connection between the controller and instance is secure. Setting this MIB to true will initiate TLS as transport protocol." DEFVAL { false } ::= { hpicfOpenFlowInstanceControllerEntry 4} hpicfOpenFlowInstanceControllerRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row status for this table. Row transition to 'createAndWait', 'notReady' and 'notInService' states are not allowed." ::= { hpicfOpenFlowInstanceControllerEntry 5} -- ------------------------------------------------------------ -- OpenFlow - Scalar Objects -- ------------------------------------------------------------ hpicfOpenFlowMaxInstances OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object specifies the maximum number of OpenFlow instances." ::= { hpicfOpenFlowObjects 10} hpicfOpenFlowMaxFlows OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB objects specifies the total number of flows that can be supported on the switch. That is, the sum of all hardware flows and software flows across all OpenFlow instances cannot exceed this number." ::= { hpicfOpenFlowObjects 11} hpicfOpenFlowMaxControllers OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object specifies the maximum number of OpenFlow controllers." ::= { hpicfOpenFlowObjects 12} ---------------------------------------------------------- -- OpenFlow Instance Meter table ---------------------------------------------------------- hpicfOpenFlowInstanceMeterTable OBJECT-TYPE SYNTAX SEQUENCE OF HpicfOpenFlowInstanceMeterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table that contains objects related to meters of an OpenFlow instance. This table is populated when meters are configured from controller." ::= { hpicfOpenFlowObjects 19 } hpicfOpenFlowInstanceMeterEntry OBJECT-TYPE SYNTAX HpicfOpenFlowInstanceMeterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of objects used to retrieve details about meters associated with an OpenFlow instance." INDEX { hpicfOpenFlowInstanceName, hpicfOpenFlowInstanceMeterID } ::= { hpicfOpenFlowInstanceMeterTable 1 } HpicfOpenFlowInstanceMeterEntry ::= SEQUENCE { hpicfOpenFlowInstanceMeterID Unsigned32, hpicfOpenFlowInstanceMeterFlowCount Unsigned32, hpicfOpenFlowInstanceMeterInputPktCount Counter64, hpicfOpenFlowInstanceMeterInputByteCount Counter64, hpicfOpenFlowInstanceMeterDuration Unsigned32 } hpicfOpenFlowInstanceMeterID OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Unique ID given to a meter." ::= { hpicfOpenFlowInstanceMeterEntry 1} hpicfOpenFlowInstanceMeterFlowCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of flows on which this meter is applied." ::= {hpicfOpenFlowInstanceMeterEntry 2} hpicfOpenFlowInstanceMeterInputPktCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of packets processed by this meter." ::= {hpicfOpenFlowInstanceMeterEntry 3} hpicfOpenFlowInstanceMeterInputByteCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of bytes processed by this meter." ::= {hpicfOpenFlowInstanceMeterEntry 4} hpicfOpenFlowInstanceMeterDuration OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Duration for which this meter is active." ::= {hpicfOpenFlowInstanceMeterEntry 5} ---------------------------------------------------------- -- OpenFlow Instance Meter Band table ---------------------------------------------------------- hpicfOpenFlowInstanceMeterBandTable OBJECT-TYPE SYNTAX SEQUENCE OF HpicfOpenFlowInstanceMeterBandEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table that contains objects related to meter bands for a specific meter in an OpenFlow instance. This table is populated when meters and their bands are configured from controller." ::= { hpicfOpenFlowObjects 20 } hpicfOpenFlowInstanceMeterBandEntry OBJECT-TYPE SYNTAX HpicfOpenFlowInstanceMeterBandEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of objects used to retrieve details about meter bands associated with a meter and an OpenFlow instance." INDEX { hpicfOpenFlowInstanceName, hpicfOpenFlowInstanceMeterID, hpicfOpenFlowInstanceMeterBandID } ::= { hpicfOpenFlowInstanceMeterBandTable 1 } HpicfOpenFlowInstanceMeterBandEntry ::= SEQUENCE { hpicfOpenFlowInstanceMeterBandID Unsigned32, hpicfOpenFlowInstanceMeterBandType INTEGER, hpicfOpenFlowInstanceMeterBandRate Unsigned32, hpicfOpenFlowInstanceMeterBandRateUnit INTEGER, hpicfOpenFlowInstanceMeterInBandPktCount Counter64, hpicfOpenFlowInstanceMeterInBandByteCount Counter64, hpicfOpenFlowInstanceMeterPrecedenceLevel Unsigned32 } hpicfOpenFlowInstanceMeterBandID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Unique ID given to a band in a meter." ::= {hpicfOpenFlowInstanceMeterBandEntry 1} hpicfOpenFlowInstanceMeterBandType OBJECT-TYPE SYNTAX INTEGER { drop(1), mark(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This meter band type determines how the packets are processed." ::= { hpicfOpenFlowInstanceMeterBandEntry 2} hpicfOpenFlowInstanceMeterBandRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object specifies the rate beyond which the incoming packets would be treated according to action specified by hpicfOpenFlowInstanceMeterBandType MIB. The units of this rate is determined by the hpicfOpenFlowInstanceMeterBandRateUnit MIB" ::= {hpicfOpenFlowInstanceMeterBandEntry 3} hpicfOpenFlowInstanceMeterBandRateUnit OBJECT-TYPE SYNTAX INTEGER { kbps(1), pps(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object specifies the unit for hpicfOpenFlowInstanceMeterBandRate MIB. The units can be either kilobits per second or packets per second." ::= {hpicfOpenFlowInstanceMeterBandEntry 4} hpicfOpenFlowInstanceMeterInBandPktCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of packets processed by this meter." ::= {hpicfOpenFlowInstanceMeterBandEntry 5} hpicfOpenFlowInstanceMeterInBandByteCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of bytes processed by this meter." ::= {hpicfOpenFlowInstanceMeterBandEntry 6} hpicfOpenFlowInstanceMeterPrecedenceLevel OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "DSCP Precedence level of the band in a meter." ::= {hpicfOpenFlowInstanceMeterBandEntry 7} ---------------------------------------------------------- -- OpenFlow Scalar Objects ---------------------------------------------------------- hpicfOpenFlowScalarObjects OBJECT IDENTIFIER ::= { hpicfOpenFlowObjects 21 } hpicfOpenFlowIPControlTableUsage OBJECT-TYPE SYNTAX Unsigned32(0..100) UNITS "%" MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to specify maximum percentage of IP control table resources that can be used by OpenFlow. The percentage is not a guarantee, but a maximum allowed limit." DEFVAL { 50 } ::= { hpicfOpenFlowScalarObjects 1} hpicfOpenFlowIPControlTableStatsRefreshRate OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object is used to specify the time interval at which the hardware will be polled for statistics. A value of '0' would mean that the hardware will no longer be polled to update the statistics." ::= { hpicfOpenFlowScalarObjects 2} hpicfOpenFlowIpControlTableMode OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This MIB object specifies the OpenFlow operation mode. In this mode, IP control table would be advertised by an OpenFlow 1.3 instance." ::= { hpicfOpenFlowScalarObjects 9 } hpicfOpenFlowEgressOnlyPorts OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this MIB object to 'enable' will advertise egress-only ports to the controller." DEFVAL { disable } ::= { hpicfOpenFlowScalarObjects 10} -- ============================================================= -- OpenFlow - Conformance Information -- ============================================================= hpicfOpenFlowCompliances OBJECT IDENTIFIER ::= { hpicfOpenFlowConformance 1 } hpicfOpenFlowGroups OBJECT IDENTIFIER ::= { hpicfOpenFlowConformance 2 } -- ============================================================= -- OpenFlow - units of conformance -- ============================================================= hpicfOpenFlowGlobalConfigGroup OBJECT-GROUP OBJECTS { hpicfOpenFlowStatus, hpicfOpenFlowMaxInstances, hpicfOpenFlowMaxFlows, hpicfOpenFlowMaxControllers } STATUS current DESCRIPTION "Controls the global configuration of OpenFlow status and allocation of policy engine resource." ::= { hpicfOpenFlowGroups 1 } hpicfOpenFlowInstanceGroup OBJECT-GROUP OBJECTS { hpicfOpenFlowInstanceAdminStatus, hpicfOpenFlowInstanceListenPortCfg, hpicfOpenFlowInstanceListenPort, hpicfOpenFlowInstanceListenPortIsOobm, hpicfOpenFlowInstanceMode, hpicfOpenFlowInstanceFlowLocationMode, hpicfOpenFlowConnectionInterruptionMode, hpicfOpenFlowInstanceHwRateLimit, hpicfOpenFlowInstanceSwRateLimit, hpicfOpenFlowInstanceDatapathID, hpicfOpenFlowInstanceNumOfHwFlows, hpicfOpenFlowInstanceNumOfSwFlows, hpicfOpenFlowInstanceOperStatus, hpicfOpenFlowInstanceMaxBackOffInterval, hpicfOpenFlowInstanceRowStatus, hpicfOpenFlowInstanceProbeInterval, hpicfOpenFlowInstanceProtoVersion, hpicfOpenFlowInstanceProtoVersionOnly, hpicfOpenFlowInstanceNumOfSwFlowTable, hpicfOpenFlowInstanceOperStatusReason, hpicfOpenFlowInstanceEgressOnlyPorts, hpicfOpenFlowInstanceCapabilities, hpicfOpenFlowInstanceHwTableMissCount, hpicfOpenFlowInstanceTableModel } STATUS deprecated DESCRIPTION "A collection of objects used to define an OpenFlow instance." ::= { hpicfOpenFlowGroups 2 } hpicfOpenFlowInstanceMembershipGroup OBJECT-GROUP OBJECTS { hpicfOpenFlowInstanceMembershipRowStatus } STATUS deprecated DESCRIPTION "An object used to associate a member to an OpenFlow instance." ::= { hpicfOpenFlowGroups 3 } hpicfOpenFlowControllerGroup OBJECT-GROUP OBJECTS { hpicfOpenFlowControllerInetAddressType, hpicfOpenFlowControllerInetAddress, hpicfOpenFlowControllerPort, hpicfOpenFlowControllerInterface, hpicfOpenFlowControllerRowStatus } STATUS deprecated DESCRIPTION "A collection of objects used to define controllers." ::= { hpicfOpenFlowGroups 4 } hpicfOpenFlowInstanceControllerGroup OBJECT-GROUP OBJECTS { hpicfOpenFlowInstanceControllerStatus, hpicfOpenFlowInstanceControllerState, hpicfOpenFlowInstanceControllerRole, hpicfOpenFlowInstanceControllerConnSecure, hpicfOpenFlowInstanceControllerRowStatus } STATUS current DESCRIPTION "A set of objects used to monitor the status and state of an OpenFlow Instance and controller connection." ::= { hpicfOpenFlowGroups 6 } hpicfOpenFlowInstanceMeterGroup OBJECT-GROUP OBJECTS { hpicfOpenFlowInstanceMeterFlowCount, hpicfOpenFlowInstanceMeterInputPktCount, hpicfOpenFlowInstanceMeterInputByteCount, hpicfOpenFlowInstanceMeterDuration } STATUS current DESCRIPTION "A collection of objects used to retrieve details about instance-specific meters." ::= { hpicfOpenFlowGroups 13 } hpicfOpenFlowInstanceMeterBandGroup OBJECT-GROUP OBJECTS { hpicfOpenFlowInstanceMeterBandType, hpicfOpenFlowInstanceMeterBandRate, hpicfOpenFlowInstanceMeterBandRateUnit, hpicfOpenFlowInstanceMeterInBandPktCount, hpicfOpenFlowInstanceMeterInBandByteCount, hpicfOpenFlowInstanceMeterPrecedenceLevel } STATUS current DESCRIPTION "A collection of objects used to retrieve details about meter band types." ::= { hpicfOpenFlowGroups 14 } hpicfOpenFlowScalarsGroup OBJECT-GROUP OBJECTS { hpicfOpenFlowIPControlTableUsage, hpicfOpenFlowIPControlTableStatsRefreshRate, hpicfOpenFlowIpControlTableMode, hpicfOpenFlowEgressOnlyPorts } STATUS deprecated DESCRIPTION "Basic Scalars required for OpenFlow implementation." ::= { hpicfOpenFlowGroups 15 } hpicfOpenFlowInstanceGroup1 OBJECT-GROUP OBJECTS { hpicfOpenFlowInstanceAdminStatus, hpicfOpenFlowInstanceListenPortCfg, hpicfOpenFlowInstanceListenPort, hpicfOpenFlowInstanceListenPortIsOobm, hpicfOpenFlowInstanceMode, hpicfOpenFlowInstanceFlowLocationMode, hpicfOpenFlowConnectionInterruptionMode, hpicfOpenFlowInstanceHwRateLimit, hpicfOpenFlowInstanceSwRateLimit, hpicfOpenFlowInstanceDatapathID, hpicfOpenFlowInstanceNumOfHwFlows, hpicfOpenFlowInstanceNumOfSwFlows, hpicfOpenFlowInstanceOperStatus, hpicfOpenFlowInstanceMaxBackOffInterval, hpicfOpenFlowInstanceRowStatus, hpicfOpenFlowInstanceProbeInterval, hpicfOpenFlowInstanceProtoVersion, hpicfOpenFlowInstanceProtoVersionOnly, hpicfOpenFlowInstanceNumOfSwFlowTable, hpicfOpenFlowInstanceOperStatusReason, hpicfOpenFlowInstanceEgressOnlyPorts, hpicfOpenFlowInstanceCapabilities, hpicfOpenFlowInstanceHwTableMissCount, hpicfOpenFlowInstanceTableModel, hpicfOpenFlowInstanceMembers, hpicfOpenFlowInstancePipelineModel, hpicfOpenFlowInstanceDatapathDesc } STATUS deprecated DESCRIPTION "A collection of objects used to define an OpenFlow instance." ::= { hpicfOpenFlowGroups 16 } hpicfOpenFlowScalarsGroup1 OBJECT-GROUP OBJECTS { hpicfOpenFlowIPControlTableUsage, hpicfOpenFlowIPControlTableStatsRefreshRate, hpicfOpenFlowEgressOnlyPorts } STATUS current DESCRIPTION "Basic Scalars required for OpenFlow implementation." ::= { hpicfOpenFlowGroups 17 } hpicfOpenFlowInstanceGroup2 OBJECT-GROUP OBJECTS { hpicfOpenFlowInstanceAdminStatus, hpicfOpenFlowInstanceListenPortCfg, hpicfOpenFlowInstanceListenPort, hpicfOpenFlowInstanceListenPortIsOobm, hpicfOpenFlowInstanceMode, hpicfOpenFlowInstanceFlowLocationMode, hpicfOpenFlowConnectionInterruptionMode, hpicfOpenFlowInstanceHwRateLimit, hpicfOpenFlowInstanceSwRateLimit, hpicfOpenFlowInstanceDatapathID, hpicfOpenFlowInstanceNumOfHwFlows, hpicfOpenFlowInstanceNumOfSwFlows, hpicfOpenFlowInstanceOperStatus, hpicfOpenFlowInstanceMaxBackOffInterval, hpicfOpenFlowInstanceRowStatus, hpicfOpenFlowInstanceProbeInterval, hpicfOpenFlowInstanceProtoVersion, hpicfOpenFlowInstanceProtoVersionOnly, hpicfOpenFlowInstanceNumOfSwFlowTable, hpicfOpenFlowInstanceOperStatusReason, hpicfOpenFlowInstanceEgressOnlyPorts, hpicfOpenFlowInstanceCapabilities, hpicfOpenFlowInstanceHwTableMissCount, hpicfOpenFlowInstanceTableModel, hpicfOpenFlowInstanceMembers, hpicfOpenFlowInstancePipelineModel, hpicfOpenFlowInstanceDatapathDesc, hpicfOpenFlowInstanceSourceMacGrpTable, hpicfOpenFlowInstanceDestMacGrpTable } STATUS deprecated DESCRIPTION "A collection of objects used to define an OpenFlow instance." ::= { hpicfOpenFlowGroups 20 } hpicfOpenFlowInstanceGroup3 OBJECT-GROUP OBJECTS { hpicfOpenFlowInstanceAdminStatus, hpicfOpenFlowInstanceListenPortCfg, hpicfOpenFlowInstanceListenPort, hpicfOpenFlowInstanceListenPortIsOobm, hpicfOpenFlowInstanceMode, hpicfOpenFlowInstanceFlowLocationMode, hpicfOpenFlowConnectionInterruptionMode, hpicfOpenFlowInstanceHwRateLimit, hpicfOpenFlowInstanceSwRateLimit, hpicfOpenFlowInstanceDatapathID, hpicfOpenFlowInstanceNumOfHwFlows, hpicfOpenFlowInstanceNumOfSwFlows, hpicfOpenFlowInstanceOperStatus, hpicfOpenFlowInstanceMaxBackOffInterval, hpicfOpenFlowInstanceRowStatus, hpicfOpenFlowInstanceProbeInterval, hpicfOpenFlowInstanceProtoVersion, hpicfOpenFlowInstanceProtoVersionOnly, hpicfOpenFlowInstanceNumOfSwFlowTable, hpicfOpenFlowInstanceOperStatusReason, hpicfOpenFlowInstanceEgressOnlyPorts, hpicfOpenFlowInstanceCapabilities, hpicfOpenFlowInstanceHwTableMissCount, hpicfOpenFlowInstanceTableModel, hpicfOpenFlowInstanceMembers, hpicfOpenFlowInstancePipelineModel, hpicfOpenFlowInstanceDatapathDesc, hpicfOpenFlowInstanceSourceMacGrpTable, hpicfOpenFlowInstanceDestMacGrpTable, hpicfOpenFlowInstanceMissRuleDefaultAction, hpicfOpenFlowInstanceOverrideProtocol, hpicfOpenFlowInstancePktInVlanTagging } STATUS current DESCRIPTION "A collection of objects used to define an OpenFlow instance." ::= { hpicfOpenFlowGroups 21 } hpicfOpenFlowControllerGroup1 OBJECT-GROUP OBJECTS { hpicfOpenFlowControllerInetAddressType, hpicfOpenFlowControllerInetAddress, hpicfOpenFlowControllerPort, hpicfOpenFlowControllerInterface, hpicfOpenFlowControllerRowStatus, hpicfOpenFlowControllerSourceAddressType, hpicfOpenFlowControllerSourceAddress } STATUS current DESCRIPTION "A collection of objects used to define controllers." ::= { hpicfOpenFlowGroups 22 } -- ============================================================= -- OpenFlow - Compliance Statements -- ============================================================= hpicfOpenFlowCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "This compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory groups." MODULE MANDATORY-GROUPS { hpicfOpenFlowGlobalConfigGroup, hpicfOpenFlowInstanceGroup, hpicfOpenFlowInstanceMembershipGroup, hpicfOpenFlowControllerGroup } GROUP hpicfOpenFlowInstanceControllerGroup DESCRIPTION "This group is optional whose objects are used to monitor the status and state of connection between an OpenFlow instance and a controller." GROUP hpicfOpenFlowInstanceMeterGroup DESCRIPTION "A collection of objects used to retrieve details about instance-specific meters." GROUP hpicfOpenFlowInstanceMeterBandGroup DESCRIPTION "A collection of objects used to retrieve details about meter band types." GROUP hpicfOpenFlowScalarsGroup DESCRIPTION "A collection of scalar objects." ::= { hpicfOpenFlowCompliances 1 } hpicfOpenFlowCompliance1 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "This compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory groups." MODULE MANDATORY-GROUPS { hpicfOpenFlowGlobalConfigGroup, hpicfOpenFlowInstanceGroup1, hpicfOpenFlowControllerGroup } GROUP hpicfOpenFlowInstanceControllerGroup DESCRIPTION "This group is optional whose objects are used to monitor the status and state of connection between an OpenFlow instance and a controller." GROUP hpicfOpenFlowInstanceMeterGroup DESCRIPTION "A collection of objects used to retrieve details about instance-specific meters." GROUP hpicfOpenFlowInstanceMeterBandGroup DESCRIPTION "A collection of objects used to retrieve details about meter band types." GROUP hpicfOpenFlowScalarsGroup1 DESCRIPTION "A collection of scalar objects." ::= { hpicfOpenFlowCompliances 2 } hpicfOpenFlowCompliance2 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "This compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory groups." MODULE MANDATORY-GROUPS { hpicfOpenFlowGlobalConfigGroup, hpicfOpenFlowInstanceGroup2, hpicfOpenFlowControllerGroup } GROUP hpicfOpenFlowInstanceControllerGroup DESCRIPTION "This group is optional whose objects are used to monitor the status and state of connection between an OpenFlow instance and a controller." GROUP hpicfOpenFlowInstanceMeterGroup DESCRIPTION "A collection of objects used to retrieve details about instance-specific meters." GROUP hpicfOpenFlowInstanceMeterBandGroup DESCRIPTION "A collection of objects used to retrieve details about meter band types." GROUP hpicfOpenFlowScalarsGroup1 DESCRIPTION "A collection of scalar objects." ::= { hpicfOpenFlowCompliances 3 } hpicfOpenFlowCompliance3 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "This compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory groups." MODULE MANDATORY-GROUPS { hpicfOpenFlowGlobalConfigGroup, hpicfOpenFlowInstanceGroup3, hpicfOpenFlowControllerGroup } GROUP hpicfOpenFlowInstanceControllerGroup DESCRIPTION "This group is optional whose objects are used to monitor the status and state of connection between an OpenFlow instance and a controller." GROUP hpicfOpenFlowInstanceMeterGroup DESCRIPTION "A collection of objects used to retrieve details about instance-specific meters." GROUP hpicfOpenFlowInstanceMeterBandGroup DESCRIPTION "A collection of objects used to retrieve details about meter band types." GROUP hpicfOpenFlowScalarsGroup1 DESCRIPTION "A collection of scalar objects." ::= { hpicfOpenFlowCompliances 4 } hpicfOpenFlowCompliance4 MODULE-COMPLIANCE STATUS current DESCRIPTION "This compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory groups." MODULE MANDATORY-GROUPS { hpicfOpenFlowGlobalConfigGroup, hpicfOpenFlowInstanceGroup3, hpicfOpenFlowControllerGroup1 } GROUP hpicfOpenFlowInstanceControllerGroup DESCRIPTION "This group is optional whose objects are used to monitor the status and state of connection between an OpenFlow instance and a controller." GROUP hpicfOpenFlowInstanceMeterGroup DESCRIPTION "A collection of objects used to retrieve details about instance-specific meters." GROUP hpicfOpenFlowInstanceMeterBandGroup DESCRIPTION "A collection of objects used to retrieve details about meter band types." GROUP hpicfOpenFlowScalarsGroup1 DESCRIPTION "A collection of scalar objects." ::= { hpicfOpenFlowCompliances 5 } END