HMIOMODULE-SNMP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, IpAddress FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC hmChassis, hmChassisEvent FROM HMPRIV-MGMT-SNMP-MIB InetPortNumber FROM INET-ADDRESS-MIB; HmEnabledStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Status of a feature" SYNTAX INTEGER { enable(1), -- feature is enabled disable(2) -- feature is disabled } -- ************************************************************************* -- Group IO Module -- ************************************************************************* hmIOModuleGroup MODULE-IDENTITY LAST-UPDATED "201011081500Z" -- 08 Nov 2010 15:00:00 GMT ORGANIZATION "Hirschmann Automation and Control GmbH" CONTACT-INFO "Customer Support Postal: Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany Tel: +49 7127 14 1981 Web: http://www.hicomcenter.com/ E-Mail: hicomcenter@hirschmann.com" DESCRIPTION "The Hirschmann Private IO Module definitions for Platform devices." -- Revision history. REVISION "201011081500Z" -- 08 Nov 2010 15:00:00 GMT DESCRIPTION "first release" ::= { hmChassis 13 } -- ************************************************************************* -- Group Config -- ************************************************************************* hmIOModuleConfigGroup OBJECT IDENTIFIER ::= { hmIOModuleGroup 1 } -- ************************************************************************* -- Goup Common Config -- ************************************************************************* hmIOModConfigCommon OBJECT IDENTIFIER ::= { hmIOModuleConfigGroup 1 } hmIOModConfigDigInputAdminState OBJECT-TYPE SYNTAX HmEnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "enables sending SNMP traps or log events on input change. (if disable(2) input task will do nothing)." DEFVAL { disable } ::= { hmIOModConfigCommon 1 } hmIOModConfigDigOutputAdminState OBJECT-TYPE SYNTAX HmEnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "enables polling of output values (if disable(2) output task will do nothing)." DEFVAL { disable } ::= { hmIOModConfigCommon 2 } hmIOModConfigDigInputRefreshInterval OBJECT-TYPE SYNTAX Integer32 (500..10000) MAX-ACCESS read-write STATUS current DESCRIPTION "The refresh interval (in ms) of the input values. Minimum 500ms, Maximum 10000ms (10s)." DEFVAL { 1000 } ::= { hmIOModConfigCommon 3 } hmIOModConfigDigOutputRefreshInterval OBJECT-TYPE SYNTAX Integer32 (500..10000) MAX-ACCESS read-write STATUS current DESCRIPTION "The refresh interval (in ms) of the output values. Minimum 500ms, Maximum 10000ms (10s)." DEFVAL { 1000 } ::= { hmIOModConfigCommon 4 } hmIOModConfigDigOutputRetryCount OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The retry count for the output values. when after the number of configured retries no SNMP get request was answered, the output value (hmIOModOutputValue) will be set to invalid (3). Minimum 1, Maximum 10." DEFVAL { 3 } ::= { hmIOModConfigCommon 5 } -- ************************************************************************* -- Table Digital Input Config -- ************************************************************************* hmIOModConfigDigInputTable OBJECT-TYPE SYNTAX SEQUENCE OF HmIOModConfigDigInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IO module config table for inputs" ::= { hmIOModuleConfigGroup 2 } hmIOModConfigDigInputEntry OBJECT-TYPE SYNTAX HmIOModConfigDigInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IO module config entry for inputs" INDEX { hmIOModConfigDigInputModID, hmIOModConfigDigInputID} ::= { hmIOModConfigDigInputTable 1 } HmIOModConfigDigInputEntry ::= SEQUENCE { hmIOModConfigDigInputModID Integer32, hmIOModConfigDigInputID Integer32, hmIOModConfigDigInputLogEvent HmEnabledStatus, hmIOModConfigDigInputSnmpTrap HmEnabledStatus } hmIOModConfigDigInputModID OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The module ID of an input." ::= { hmIOModConfigDigInputEntry 1 } hmIOModConfigDigInputID OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ID of an input." ::= { hmIOModConfigDigInputEntry 2 } hmIOModConfigDigInputLogEvent OBJECT-TYPE SYNTAX HmEnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Trigger an event log when input status changes. If the value is disable (2), no event log entry will be written. If the value is enable (1), an event log entry will be written when the input state changes. The input state will be checked acording to the refresh interval entered in hmIOModConfigDigInputRefreshInterval." DEFVAL { disable } ::= { hmIOModConfigDigInputEntry 3 } hmIOModConfigDigInputSnmpTrap OBJECT-TYPE SYNTAX HmEnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Trigger an SNMP trap log when input status changes. If the value is disable (2), no SNMP trap will be sent. If the value is enable (1), a SNMP trap will be sent when the input state changes. The SNMP trap will be sent to all receivers configured in hmAgentSnmpTrapReceiverConfigTable. The input state will be checked acording to the refresh interval entered in hmIOModConfigDigInputRefreshInterval." DEFVAL { disable } ::= { hmIOModConfigDigInputEntry 4 } -- ************************************************************************* -- Table Digital Output Config -- ************************************************************************* hmIOModConfigDigOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF HmIOModConfigDigOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IO module config table for outputs" ::= { hmIOModuleConfigGroup 3 } hmIOModConfigDigOutputEntry OBJECT-TYPE SYNTAX HmIOModConfigDigOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IO module config entry for outputs" INDEX { hmIOModConfigDigOutputModID, hmIOModConfigDigOutputID } ::= { hmIOModConfigDigOutputTable 1 } HmIOModConfigDigOutputEntry ::= SEQUENCE { hmIOModConfigDigOutputModID Integer32, hmIOModConfigDigOutputID Integer32, hmIOModConfigDigOutputLogEvent HmEnabledStatus, hmIOModConfigDigOutputSnmpTrap HmEnabledStatus, hmIOModConfigDigOutputSourceIP IpAddress, hmIOModConfigDigOutputSourceModID Integer32, hmIOModConfigDigOutputSourceID Integer32, hmIOModConfigDigOutputSourcePort InetPortNumber} hmIOModConfigDigOutputModID OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The module ID of an output." ::= { hmIOModConfigDigOutputEntry 1 } hmIOModConfigDigOutputID OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ID of an output." ::= { hmIOModConfigDigOutputEntry 2 } hmIOModConfigDigOutputLogEvent OBJECT-TYPE SYNTAX HmEnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Trigger an event log when output status changes. If the value is disable (2), no event log entry will be written. If the value is enable (1), an event log entry will be written when the output state changes. The output state will be checked acording to the refresh interval entered in hmIOModConfigDigOutputRefreshInterval." DEFVAL { disable } ::= { hmIOModConfigDigOutputEntry 3 } hmIOModConfigDigOutputSnmpTrap OBJECT-TYPE SYNTAX HmEnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Trigger an SNMP trap log when output status changes. If the value is disable (2), no SNMP trap will be sent. If the value is enable (1), a SNMP trap will be sent when the output state changes. The SNMP trap will be sent to all receivers configured in hmAgentSnmpTrapReceiverConfigTable. The output state will be checked acording to the refresh interval entered in hmIOModConfigDigOutputRefreshInterval." DEFVAL { disable } ::= { hmIOModConfigDigOutputEntry 4 } hmIOModConfigDigOutputSourceIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of an input mirrored to the output. Use 0.0.0.0 if the output should not be set. In this case hmIOModOutputValue is invalid (3). Use 127.0.0.1 if an local input should be used." DEFVAL { "0.0.0.0" } ::= { hmIOModConfigDigOutputEntry 5 } hmIOModConfigDigOutputSourceModID OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-write STATUS current DESCRIPTION "The module ID of an input mirrored to the output. Ignored when hmIOModConfigDigOutputSourceIP is 0.0.0.0." DEFVAL { 1 } ::= { hmIOModConfigDigOutputEntry 6 } hmIOModConfigDigOutputSourceID OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-write STATUS current DESCRIPTION "The ID of an input mirrored to the output. Ignored when hmIOModConfigDigOutputSourceIP is 0.0.0.0." DEFVAL { 1 } ::= { hmIOModConfigDigOutputEntry 7 } hmIOModConfigDigOutputSourcePort OBJECT-TYPE SYNTAX InetPortNumber MAX-ACCESS read-write STATUS current DESCRIPTION "The SNMP port number being used by the input mirrored to the output. This port would be the destination for the SNMP requests for polling the state of the input." DEFVAL { 161 } ::= { hmIOModConfigDigOutputEntry 8 } -- ************************************************************************* -- Group Value -- ************************************************************************* hmIOModuleValueGroup OBJECT IDENTIFIER ::= { hmIOModuleGroup 2 } -- ************************************************************************* -- Table Digital Input Value -- ************************************************************************* hmIOModValueDigInputTable OBJECT-TYPE SYNTAX SEQUENCE OF HmIOModValueDigInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IO module value table for inputs" ::= { hmIOModuleValueGroup 1 } hmIOModValueDigInputEntry OBJECT-TYPE SYNTAX HmIOModValueDigInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IO module value entry for inputs" INDEX { hmIOModValueDigInputModID, hmIOModValueDigInputID} ::= { hmIOModValueDigInputTable 1 } HmIOModValueDigInputEntry ::= SEQUENCE { hmIOModValueDigInputModID Integer32, hmIOModValueDigInputID Integer32, hmIOModValueDigInputValue INTEGER} hmIOModValueDigInputModID OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The module ID of an input." ::= { hmIOModValueDigInputEntry 1 } hmIOModValueDigInputID OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ID of an input." ::= { hmIOModValueDigInputEntry 2 } hmIOModValueDigInputValue OBJECT-TYPE SYNTAX INTEGER { not-available (0), high (1), low (2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the input. If the value is not-available(0), then the IO module is not plugged in, if the value is high(1), the input has high (+24V) value, if the value is low(2), the input has low (0V) value." ::= { hmIOModValueDigInputEntry 3 } -- ************************************************************************* -- Table Digital Output Value -- ************************************************************************* hmIOModValueDigOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF HmIOModValueDigOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IO module value table for outputs" ::= { hmIOModuleValueGroup 2 } hmIOModValueDigOutputEntry OBJECT-TYPE SYNTAX HmIOModValueDigOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IO module value entry for outputs" INDEX { hmIOModValueDigOutputModID, hmIOModValueDigOutputID } ::= { hmIOModValueDigOutputTable 1 } HmIOModValueDigOutputEntry ::= SEQUENCE { hmIOModValueDigOutputModID Integer32, hmIOModValueDigOutputID Integer32, hmIOModValueDigOutputValue INTEGER} hmIOModValueDigOutputModID OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The module ID of an Output." ::= { hmIOModValueDigOutputEntry 1 } hmIOModValueDigOutputID OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ID of an Output." ::= { hmIOModValueDigOutputEntry 2 } hmIOModValueDigOutputValue OBJECT-TYPE SYNTAX INTEGER { not-available (0), high (1), low (2), invalid (3), not-configured (4)} MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the output. If the value is not-available(0), then the IO module is not plugged in, if the value is high(1), the output has high (+24V) value, if the value is low(2), the output has low (0V) value. If the value is invalid (3), the output has low (0V) value and the IO input source is configured but can not be read. If the value is not-configured (4), the output has low (0V) value and has no IO input source configured." ::= { hmIOModValueDigOutputEntry 3 } -- ************************************************************************* -- TRAP's -- ************************************************************************* hmIOModDigInputChangeTrap NOTIFICATION-TYPE OBJECTS { hmIOModValueDigInputValue} STATUS current DESCRIPTION "This trap is sent if the state of an input changes. This trap is sent only when hmIOModConfigDigInputSnmpTrap is set to enabled (1)." ::= { hmChassisEvent 16 } hmIOModDigOutputChangeTrap NOTIFICATION-TYPE OBJECTS { hmIOModValueDigOutputValue} STATUS current DESCRIPTION "This trap is sent if the state of an input changes. This trap is sent when hmIOModConfigDigOutputSnmpTrap is set to enabled (1) or when the output value changes from or to invalid (3)" ::= { hmChassisEvent 17 } END